MIBs Depot

ZHONE-GEN-ALARM

Registered at
1.3.6.1.4.1.5504.3.1.18
1.3.6.1.4.1.5504.6.79
Last updated
2004-02-18 14:30
Organization
Zhone Technologies, Inc.
Revisions
2004-02-18 14:30, 2004-01-12 13:37
Namespace
zhone
Source file
ZHONE-GEN-ALARM
Digest
sha256:a9f5f4d0a88e23d97fdd0a74b4e3b611049152816c558e4eadb314248f5672cf

Description

Centralized Alarm MIB

Contact

Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Opaque, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
ZhonezhoneModules, zhoneSystem
Zhone-TCZhoneAlarmSeverity, ZhoneAlarmTypeId

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
ZHONE-GEN-ALARM
Zhone
Zhone-TC

Textual conventions

NameOIDSyntaxAccessStatus
ZhoneAlarmActiveVariableValue
TEXTUAL-CONVENTION
The type of the varbind value. One and only one of the value objects that follows is used for a given row in this table.
current

Objects

NameOIDSyntaxAccessStatus
zhoneAlarm
OBJECT-IDENTITY
This entry list contains tables of the active outstanding alarms in a system. It also provides statistical information in terms of total # of active alarms raised.
1.3.6.1.4.1.5504.3.1.18current
zhoneAlarmStats
OBJECT-IDENTITY
1.3.6.1.4.1.5504.3.1.18.1
zhoneAlarmActiveOverflowCnt
OBJECT-TYPE
The number of active alarms that have not been put into the alarmActiveTable since system restart as a result of extreme resource constraints. This counter wrapped around once it reaches its maximum value.
1.3.6.1.4.1.5504.3.1.18.1.1Counter32read-onlycurrent
zhoneAlarmActiveStatsCurrentCnt
OBJECT-TYPE
The total number of currently active alarms on the system. This counter wrapped around once it reaches its maximum value.
1.3.6.1.4.1.5504.3.1.18.1.2Counter32read-onlycurrent
zhoneAlarmActiveStatsTotalCnt
OBJECT-TYPE
The total number of active alarms since system restarted. This counter wrapped around once it reaches its maximum value.
1.3.6.1.4.1.5504.3.1.18.1.3Counter32read-onlycurrent
zhoneAlarmClearStatsTotalCnt
OBJECT-TYPE
The total number of cleared alarms since system restarted. This counter wrapped around once it reaches its maximum value.
1.3.6.1.4.1.5504.3.1.18.1.4Counter32read-onlycurrent
zhoneAlarmLastRaised
OBJECT-TYPE
The value of sysUpTime at the time of the last alarm raise for this alarm list. If no alarm raises have occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.
1.3.6.1.4.1.5504.3.1.18.1.5TimeTicksread-onlycurrent
zhoneAlarmLastCleared
OBJECT-TYPE
The value of sysUpTime at the time of the last alarm clear for this alarm list. If no alarm clears have occurred since the last re-initialization of the local network management subsystem, then this object contains a zero value.
1.3.6.1.4.1.5504.3.1.18.1.6TimeTicksread-onlycurrent
zhoneAlarmModelTable
OBJECT-TYPE
This table contains the information in order to obtain the unique object instance id for every active alarm in the zhoneAlarmActiveTable.
1.3.6.1.4.1.5504.3.1.18.2not-accessiblecurrent
zhoneAlarmModelEntry
OBJECT-TYPE
The zhoneAlarmModeEntries indicate which variableId (Varbind #) indicates the object instance for which an active alarm was raised/cleared.
1.3.6.1.4.1.5504.3.1.18.2.1not-accessiblecurrent
zhoneAlarmModelAlarmId
OBJECT-TYPE
This entry specifies the alarm ID number.
1.3.6.1.4.1.5504.3.1.18.2.1.1ZhoneAlarmTypeIdnot-accessiblecurrent
zhoneAlarmModelNotificationId
OBJECT-TYPE
The trap object identifier (OID) value that allows for the given alarmTypeId to be set or cleared. This value is used as an index to the zhoneAlarmModelTable.
1.3.6.1.4.1.5504.3.1.18.2.1.2OBJECT IDENTIFIERnot-accessiblecurrent
zhoneAlarmModelVariableId
OBJECT-TYPE
The zhoneAlarmModelVariableId identifies the varbind number for a given alarmActiveId and NotificationId that contains the unique object instance that raised/cleared that alarm.
1.3.6.1.4.1.5504.3.1.18.2.1.3Integer32read-onlycurrent
zhoneAlarmModelDescription
OBJECT-TYPE
This entry provides a text information of the alarm.
1.3.6.1.4.1.5504.3.1.18.2.1.4OCTET STRINGread-onlycurrent
zhoneAlarmActiveTable
OBJECT-TYPE
A table of Active Outstanding Alarm entries in a system.
1.3.6.1.4.1.5504.3.1.18.3not-accessiblecurrent
zhoneAlarmActiveEntry
OBJECT-TYPE
Entries appear in this table when alarms are raised. The active alarm entries are removed when the alarm is cleared. If under extreme resource constraint the system is unable to add any more entries into this table, then the alarmActiveOverflow statistic will be increased by one.
1.3.6.1.4.1.5504.3.1.18.3.1not-accessiblecurrent
zhoneAlarmActiveId
OBJECT-TYPE
This entry specifies the alarm ID number.
1.3.6.1.4.1.5504.3.1.18.3.1.1ZhoneAlarmTypeIdnot-accessiblecurrent
zhoneAlarmActiveResourceId
OBJECT-TYPE
This object identifies the resource under alarm. The resource id can be determined based on the varbind # that determines the resource id. The mapping of which varbind defines the resource id is defined in the zhoneAlarmModelTable. For every alarmTypeId, there is a definition of which traps set/clear that alarm and the varbind number that determines the object instance that the alarm is raised/cleared (resource id). If there is no corresponding resource, then the value of this object is 0.0.
1.3.6.1.4.1.5504.3.1.18.3.1.2OBJECT IDENTIFIERnot-accessiblecurrent
zhoneAlarmActiveVariables
OBJECT-TYPE
The number of variables (varbinds) in alarmActiveVariableTable for this alarm.
1.3.6.1.4.1.5504.3.1.18.3.1.3Unsigned32read-onlycurrent
zhoneAlarmActiveNotificationId
OBJECT-TYPE
The Trap object identifier of the alarm state transition that is occurring. This entry indicates the trap oid that caused the alarm to be raised.
1.3.6.1.4.1.5504.3.1.18.3.1.4OBJECT IDENTIFIERread-onlycurrent
zhoneAlarmActiveSeverity
OBJECT-TYPE
This entry identifies the severity level of the alarm.
1.3.6.1.4.1.5504.3.1.18.3.1.5ZhoneAlarmSeverityread-onlycurrent
zhoneAlarmActiveVariableTable
OBJECT-TYPE
A table of variables to go with each active alarm entries.
1.3.6.1.4.1.5504.3.1.18.4not-accessiblecurrent
zhoneAlarmActiveVariableEntry
OBJECT-TYPE
Entries appear in this table when there are variables in the varbind list of a corresponding alarm in zhoneAlarmActiveTable. Entries appear in this table as though the trap/notification had been transported using zhone Trap definition.
1.3.6.1.4.1.5504.3.1.18.4.1not-accessiblecurrent
zhoneAlarmActiveVariableId
OBJECT-TYPE
The alarm variable's object identifier.
1.3.6.1.4.1.5504.3.1.18.4.1.1Integer32 (1..2147483647)not-accessiblecurrent
zhoneAlarmActiveVariableValueType
OBJECT-TYPE
The type of the value. One and only one of the value objects that follow is used for a given row in this table, based on this type.
1.3.6.1.4.1.5504.3.1.18.4.1.2ZhoneAlarmActiveVariableValueread-onlycurrent
zhoneAlarmActiveVariableCounter32Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'counter32'.
1.3.6.1.4.1.5504.3.1.18.4.1.3Counter32read-onlycurrent
zhoneAlarmActiveVariableUnsigned32Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'unsigned32'.
1.3.6.1.4.1.5504.3.1.18.4.1.4Unsigned32read-onlycurrent
zhoneAlarmActiveVariableTimeTicksVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'timeTicks'.
1.3.6.1.4.1.5504.3.1.18.4.1.5TimeTicksread-onlycurrent
zhoneAlarmActiveVariableInteger32Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'integer32'.
1.3.6.1.4.1.5504.3.1.18.4.1.6Integer32read-onlycurrent
zhoneAlarmActiveVariableOctetStringVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'octetString'.
1.3.6.1.4.1.5504.3.1.18.4.1.7OCTET STRING (SIZE(0..65535))read-onlycurrent
zhoneAlarmActiveVariableIpAddressVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'ipAddress'.
1.3.6.1.4.1.5504.3.1.18.4.1.8IpAddressread-onlycurrent
zhoneAlarmActiveVariableOidVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'objectId'.
1.3.6.1.4.1.5504.3.1.18.4.1.9OBJECT IDENTIFIERread-onlycurrent
zhoneAlarmActiveVariableCounter64Val
OBJECT-TYPE
The value when alarmActiveVariableType is 'counter64'.
1.3.6.1.4.1.5504.3.1.18.4.1.10Counter64read-onlycurrent
zhoneAlarmActiveVariableOpaqueVal
OBJECT-TYPE
The value when alarmActiveVariableType is 'opaque'. Note that although RFC2578 [RFC2578] forbids the use of Opaque in 'standard' MIB modules, this particular usage is driven by the need to be able to accurately represent any well-formed notification, and justified by the need for backward compatibility.
1.3.6.1.4.1.5504.3.1.18.4.1.11Opaqueread-onlycurrent
zhoneAlarmActiveVariableResourceId
OBJECT-TYPE
This is the instance OID for the variable binding whose instance OID is different from that of the zhoneAlarmActiveResourceId. If this instance OID is not required or the same as zhoneAlarmActiveResourceId, it will have a default value of 0.0. For example: atmVclOperStatusChange would have ifIndex.vpi.vci as its alarm resource Id. But for the trap variable binding of zhoneTrapPort, the instance id is 0.
1.3.6.1.4.1.5504.3.1.18.4.1.12OBJECT IDENTIFIERread-onlycurrent

Conformance

NameOIDStatus
zhoneAlarmGroup
OBJECT-GROUP
Alarm MIB Group Definition for all Alarm MIB Entries.
1.3.6.1.4.1.5504.3.1.18.5current