ZHONE-CONSOLE- Digest
sha256:97dc3d96a7367f9e9759c097a028f5c7f4ccd7f35578a80dcef809959cdd5587
Description
The Zhone console mib that applies to the console connection to an Information Services card. There is only one supported connection at a time, thus the single instance implementation.
Contact
Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TimeStamp |
| Zhone | zhoneConsole, zhoneModules |
| Zhone-TC | ZhoneAdminString |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC ZHONE-CONSOLE Zhone Zhone-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| consoleHeight OBJECT-TYPE The height of the console in the number of lines displayed. The default value is 24. | 1.3.6.1.4.1.5504.5.5.1 | Integer32 (24..120) | read-write | current |
| consoleCurrentUser OBJECT-TYPE The name of the current or last user logged in to the system. | 1.3.6.1.4.1.5504.5.5.2 | ZhoneAdminString | read-only | current |
| consoleLastLoginTime OBJECT-TYPE Time at which the last user logged in. If a user has never logged in on this system, the value returned is 0. This is the sysuptime value as defined in rfc1907. | 1.3.6.1.4.1.5504.5.5.3 | TimeStamp | read-only | current |
| consoleLastLogoutTime OBJECT-TYPE The sysuptime at which the last user logged out. A value of 0 is returned if a logout has never occured OR if a user is currently logged in. | 1.3.6.1.4.1.5504.5.5.4 | TimeStamp | read-only | current |
| consoleCharsOut OBJECT-TYPE The number of characters sent by the console since initialization. | 1.3.6.1.4.1.5504.5.5.5 | Counter32 | read-only | current |
| consoleCharsIn OBJECT-TYPE The number of charcters received by the console since initialization. | 1.3.6.1.4.1.5504.5.5.6 | Counter32 | read-only | current |
| consoleBaudRate OBJECT-TYPE The speed of the console serial port, in characters per second. The default value is determined by the particular platform. Current known values are 57600 for the BAN and 9600 for other devices. | 1.3.6.1.4.1.5504.5.5.7 | INTEGER {gcAutoBaud(1), gc9600(2), gc19200(3), gc38400(4), gc57600(5)} | read-write | current |
| consoleInactivityTime OBJECT-TYPE The console inactivity time where after this number of minutes, the user is automatically logged out. A value of 0 disables the timer. The default is 30 minutes. | 1.3.6.1.4.1.5504.5.5.8 | Integer32 (0..60) | read-write | current |