MIBs Depot

ZHONE-COM-ATM-MIB

Registered at
1.3.6.1.4.1.5504.4.2.2
1.3.6.1.4.1.5504.6.25
Last updated
2005-04-05 12:00
Organization
Zhone Technologies, Inc.
Revisions
2005-04-05 16:44, 2005-02-28 13:18, 2004-09-07 10:44, 2004-06-19 10:15, 2004-01-28 12:42, 2003-12-04 15:23, 2003-09-09 14:11, 2003-04-16 16:04, 2003-03-11 13:46, 2003-02-14 16:55, 2003-02-11 13:30, 2002-08-23 10:36, 2002-08-13 16:14, 2002-06-04 20:13, 2002-05-28 12:12, 2002-05-21 17:29, 2002-05-15 17:29, 2002-03-20 20:19, 2001-12-19 15:24, 2001-11-02 17:22, 2001-10-29 17:34, 2001-09-20 10:54, 2001-08-30 17:15, 2001-08-14 12:00, 2001-07-11 12:00
Namespace
zhone
Source file
ZHONE-COM-ATM-MIB
Digest
sha256:83148cd4c1978051f0b8df70ca5ca820e10bd82f3196024f1af6485b3616e850

Description

This is the Zhone module identifier for the Zhone ATM MIB extension module.

Contact

Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com

Imports

FromSymbols
ATM-MIBatmInterfaceDs3PlcpAlarmState, atmInterfaceTCAlarmState, atmInterfaceTCEntry, atmTrafficDescrParamEntry, atmVcCrossConnectEntry, atmVccAal5CpcsReceiveSduSize, atmVccAal5CpcsTransmitSduSize, atmVccAal5EncapsType, atmVccAalType, atmVclAdminStatus, atmVclCastType, atmVclConnKind, atmVclCrossConnectIdentifier, atmVclEntry, atmVclLastChange, atmVclOperStatus, atmVclReceiveTrafficDescrIndex, atmVclRowStatus, atmVclTransmitTrafficDescrIndex, atmVclVci, atmVclVpi, atmVplAdminStatus, atmVplCastType, atmVplConnKind, atmVplCrossConnectIdentifier, atmVplEntry, atmVplLastChange, atmVplOperStatus, atmVplReceiveTrafficDescrIndex, atmVplRowStatus, atmVplTransmitTrafficDescrIndex, atmVplVpi
ATM-TC-MIBAtmVcIdentifier, AtmVpIdentifier
IF-MIBInterfaceIndex, ifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue
ZhonezhoneAtm, zhoneModules, zhoneShelfIndex, zhoneSlotIndex
Zhone-TCZhoneAdminString, ZhoneRowStatus

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ATM-MIB
ATM-TC-MIB
IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
ZHONE-COM-ATM-MIB
Zhone
Zhone-TC

Objects

NameOIDSyntaxAccessStatus
zhoneAtmExtension
OBJECT-IDENTITY
This is the Zhone extension MIB tree to the standard ATM defined by rfc2515.
1.3.6.1.4.1.5504.4.2.2current
zhoneAtmVclExtTable
OBJECT-TYPE
Zhone extension table for the atmVclTable defined in rfc2515.
1.3.6.1.4.1.5504.4.2.2.1not-accessiblecurrent
zhoneAtmVclExtEntry
OBJECT-TYPE
An entry in the atmVclExtTable. atmVclExtEntry is an augmentation to the atmVclEntry defined in rfc2515.
1.3.6.1.4.1.5504.4.2.2.1.1not-accessiblecurrent
zhoneAtmVclExtFaultDetectionType
OBJECT-TYPE
This is used to configure VCL fault detection. The valid values are: * disabled - Fault detection is disabled. This is the default. * oamF5Loopback - This option uses standard OAM fault management cells as defined in ITU.610 for fault detection. Automatic loopback diagnostic cells are sent to the IAD. When fault detection is enabled, atmVclOperStatusChange notification trap is used to indicate to the NMS station an VCL has gone down or has come back up.
1.3.6.1.4.1.5504.4.2.2.1.1.1INTEGER {disabled(1), oamF5Loopback(2)}read-createcurrent
zhoneAtmVclExtOamF5Ping
OBJECT-TYPE
This is used to send a OAM F5 loopback cell for fault detection. The value will automatically revert to disabled after the set is complete. The valid values are: * disabled - OAM F5 loopback cell is not being sent. This is the default. * endToEnd - This option uses standard OAM fault management cells as defined in ITU.610 for fault detection. Setting this will send a OAM F5 end-to-end loopback cell to be sent * segment - This is not supported at this time
1.3.6.1.4.1.5504.4.2.2.1.1.2INTEGER {disabled(1), endToEnd(2), segment(3)}read-createcurrent
zhoneAtmVclExtOamF5PingStatus
OBJECT-TYPE
TRUE if ping was successfull and FALSE if failed
1.3.6.1.4.1.5504.4.2.2.1.1.3TruthValueaccessible-for-notifycurrent
zhoneAtmVclExtTrafficContainerIndex
OBJECT-TYPE
Index number of a PON traffic container associated with a VCL definition.
1.3.6.1.4.1.5504.4.2.2.1.1.4Integer32 (0..2147483647)read-createcurrent
zhoneAtmVclExtOamF4Ping
OBJECT-TYPE
This is used to send a OAM F4 loopback cell for fault detection. The value will automatically revert to disabled after the set is complete. The valid values are: * disabled - OAM F4 loopback cell is not being sent. This is the default. * endToEnd - This option uses standard OAM fault management cells as defined in ITU.610 for fault detection. Setting this will send a OAM F4 end-to-end loopback cell to be sent * segment - This is not supported at this time
1.3.6.1.4.1.5504.4.2.2.1.1.5INTEGER {disabled(1), endToEnd(2), segment(3)}read-createcurrent
zhoneAtmVclExtOamF4PingStatus
OBJECT-TYPE
TRUE if ping was successfull and FALSE if failed.
1.3.6.1.4.1.5504.4.2.2.1.1.6TruthValueaccessible-for-notifycurrent
zhoneAtmTraps
OBJECT-IDENTITY
All the Zhone ATM traps will be defined under this OID.
1.3.6.1.4.1.5504.4.2.2.2current
zhoneAtmV2Traps
OBJECT-IDENTITY
This object identity adds a zero(0) for the next to last sub-identifier which should be used for new SNMPv2 Traps.
1.3.6.1.4.1.5504.4.2.2.2.0current
zhoneAtmGroups
OBJECT-IDENTITY
Zhone ATM object groups and notification groups will be defined under this object identity.
1.3.6.1.4.1.5504.4.2.2.3current
zhoneAtmTrafficDescrParamExtTable
OBJECT-TYPE
Zhone extension table for the atmTrafficDescrParamTable defined in rfc2515.
1.3.6.1.4.1.5504.4.2.2.4not-accessiblecurrent
zhoneAtmTrafficDescrParamExtEntry
OBJECT-TYPE
This is extension of AtmTrafficDescrParamEntry defined in rfc2515.
1.3.6.1.4.1.5504.4.2.2.4.1not-accessiblecurrent
zhoneAtmTrafficDescrParamExtTrnkVclRate
OBJECT-TYPE
This field is used to describe the minimum guaranteed rate for a VCL which is bound to this traffic descriptor for BAN ATM Trunk Cards. It is applicable only for RTVBR service category. Unlike switched voice calls in the TDM world we cannot oversubscribe bandwidth because all of our voice calls must be connected at all times so that we can receive signaling to tell us that the phone when off hook. Instead of oversubscribing we suggest that the service provide under provision their voice calls. An example of this would be a normal good quality voice call over ATM requires about 80kb of bandwidth. To share the bandwidth resource over several customers the service provider would instead allocate (for example) rate16K for a single voice channel, this would allow 5 channels to share the bandwidth required to connect a good quality voice call. Any value less than rate80K could be used if the service provider wished to share bandwidth resources over more than one voice call. In order for this method to produce a good quality voice call enough bandwidth must be unallocated and used in a shared pool by all connections. When the buffering is not adequate for a good quality call the connection will not terminate, instead the call quality will suffer. Values greater than rate80K would be used by devices like a PBX. For all service categories other than RTVBR, unused is the only valid value.For RTVBR unused is not a valid value and one of the rates has to be specified. This parameter is used independently for transmit and receive traffic based on the traffic descriptor specified for transmit and receive in the VCL. Changing this parameter may cause a trap if newly utilized bandwidth for a card exceeds its available bandwidth. It may happen on multiple cards and therefore there can be multiple traps.
1.3.6.1.4.1.5504.4.2.2.4.1.1INTEGER {unused(1), rate16K(2), rate32K(3), rate64K(4), rate80K(5), rate128K(6), rate160K(7), rate256K(8), rate320K(9), rate512K(10), rate640K(11), rate1552K(12), rate2050K(13), rate12M(14), rate16M(15), rate45M(16), rate155M(17), rate960K(18), rate1280K(19), rate1760K(20), rate3M(21), rate4M(22), rate5M(23), rate6M(24), rate7M(25), rate8M(26), rate10M(27), rate14M(28), rate24M(29), rate32M(30), rate64M(31), rate96M(32), rate128M(33)}read-createcurrent
zhoneAtmTrafficDescrParamExtCacDivider
OBJECT-TYPE
This object allows users to oversubsribe. The rate subtracted from CAC is PCR or SCR divided by this object.
1.3.6.1.4.1.5504.4.2.2.4.1.2Integer32read-writecurrent
zhoneAtmTrafficDescrParamExtUsageParameterControl
OBJECT-TYPE
If set to 'false', this object disables polcing.
1.3.6.1.4.1.5504.4.2.2.4.1.3TruthValueread-createcurrent
zhoneAtmStatsExtTable
OBJECT-TYPE
These statistics values are coming from fabric interface.
1.3.6.1.4.1.5504.4.2.2.5not-accessiblecurrent
zhoneAtmStatsExtEntry
OBJECT-TYPE
Definitions of Forward and Backward: Internal to ATM Switch Fabric ============================================================= |Ext|==>IngressFwd==>| |==>EgressFwd====>|Int| PortPhy<->|VC | |APC Switch Fabric| |VC |<->Bus/SAR/DSP | |<==EgressBack<==| |<==IngressBack<==| | Phy =============================================================
1.3.6.1.4.1.5504.4.2.2.5.1not-accessiblecurrent
zhoneAtmStatsTotalInitialCellsRx
OBJECT-TYPE
Total Initial Cells Received. Total cells received across the ingress interface for a given VC, and not discarded by policing prior to thresholding (includes CPU insertions but excludes Atm switch fabric generated ingress OAM insertions).
1.3.6.1.4.1.5504.4.2.2.5.1.1Counter64read-onlycurrent
zhoneAtmStatsTotalFabricCellsRx
OBJECT-TYPE
Total Cells Recevied at Fabric.Total cells received across the fabric interface for a given VC, including cells discarded due to parity errors.
1.3.6.1.4.1.5504.4.2.2.5.1.2Counter64read-onlycurrent
zhoneAtmStatsTotalFinalCLP0CellsRx
OBJECT-TYPE
Total CLP0 Cells received by fabric. This field is setup to monitor egress total cells transmitted CLP0.
1.3.6.1.4.1.5504.4.2.2.5.1.3Counter64read-onlycurrent
zhoneAtmStatsTotalFinalCLP1CellsRx
OBJECT-TYPE
Total CLP1 Cells received by fabric. This field is setup to monitor egress total cells transmitted CLP1.
1.3.6.1.4.1.5504.4.2.2.5.1.4Counter64read-onlycurrent
zhoneAtmStatsTotalInitialCellsTx
OBJECT-TYPE
Initial Total Cells Transmitted. Total cells transmitted. across the ingress interface for a given VC, and not discarded by policing prior to thresholding (includes CPU insertions but excludes Atm switch fabric generated ingress OAM insertions).
1.3.6.1.4.1.5504.4.2.2.5.1.5Counter64read-onlycurrent
zhoneAtmStatsTotalFabricCellsTx
OBJECT-TYPE
Total cells transmitted at fabric interace.Total cells transmitted across the fabric interface for a given VC, including cells discarded due to parity errors.
1.3.6.1.4.1.5504.4.2.2.5.1.6Counter64read-onlycurrent
zhoneAtmStatsTotalFinalCLP0CellsTx
OBJECT-TYPE
Total CLP0 Cells Transmitted. This field is setup to monitor egress total cells transmitted CLP0.
1.3.6.1.4.1.5504.4.2.2.5.1.7Counter64read-onlycurrent
zhoneAtmStatsTotalFinalCLP1CellsTx
OBJECT-TYPE
Total CLP1 Cells Transmitted. This field is setup to monitor egress total cells transmitted CLP1.
1.3.6.1.4.1.5504.4.2.2.5.1.8Counter64read-onlycurrent
zhoneAtmVclRateExtParam
OBJECT-IDENTITY
This is the Zhone extension MIB tree to the ATM VCL rates.
1.3.6.1.4.1.5504.4.2.2.6current
zhoneAtmVclRateExtParam1
OBJECT-TYPE
This field is used to describe the first least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards. It is applicable only for RTVBR/NRTVBR or CBR service category. For RTVBR/NRTVBR service category, this value can be set in the rfc2515 td_param2 of the traffice descriptor table. For CBR service category, this value can be set in the td_param1 field. The maximum rates capacitiy is 16, any value which is not matched in any one of those 16 rates will be rejected. Unlike switched voice calls in the TDM world we cannot oversubscribe bandwidth because all of our voice calls must be connected at all times so that we can receive signaling to tell us that the phone when off hook. Instead of oversubscribing we suggest that the service provide under provision their voice calls. An example of this would be a normal good quality voice call over ATM requires about 189 CPS. To share the bandwidth resource over several customers the service provider would instead allocate (for example) 38 CPS for a single voice channel, this would allow 5 channels to share the bandwidth required to connect a good quality voice call. Any value less than 189 CPS could be used if the service provider wished to share bandwidth resources over more than one voice call. In order for this method to produce a good quality voice call enough bandwidth must be unallocated and used in a shared pool by all connections. When the buffering is not adequate for a good quality call the connection will not terminate, instead the call quality will suffer. Values greater than 189 CPS would be used by devices like a PBX. This parameter is used independently for transmit and receive traffic based on the traffic descriptor specified for transmit and receive in the VCL.
1.3.6.1.4.1.5504.4.2.2.6.1Integer32read-writecurrent
zhoneAtmVclRateExtParam2
OBJECT-TYPE
This field is used to describe the second least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.2Integer32read-writecurrent
zhoneAtmVclRateExtParam3
OBJECT-TYPE
This field is used to describe the third least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.3Integer32read-writecurrent
zhoneAtmVclRateExtParam4
OBJECT-TYPE
This field is used to describe the fourth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.4Integer32read-writecurrent
zhoneAtmVclRateExtParam5
OBJECT-TYPE
This field is used to describe the fifth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.5Integer32read-writecurrent
zhoneAtmVclRateExtParam6
OBJECT-TYPE
This field is used to describe the sixth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.6Integer32read-writecurrent
zhoneAtmVclRateExtParam7
OBJECT-TYPE
This field is used to describe the seventh least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.7Integer32read-writecurrent
zhoneAtmVclRateExtParam8
OBJECT-TYPE
This field is used to describe the eighth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.8Integer32read-writecurrent
zhoneAtmVclRateExtParam9
OBJECT-TYPE
This field is used to describe the ninth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.9Integer32read-writecurrent
zhoneAtmVclRateExtParam10
OBJECT-TYPE
This field is used to describe the tenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.10Integer32read-writecurrent
zhoneAtmVclRateExtParam11
OBJECT-TYPE
This field is used to describe the eleventh least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.11Integer32read-writecurrent
zhoneAtmVclRateExtParam12
OBJECT-TYPE
This field is used to describe the twelfth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.12Integer32read-writecurrent
zhoneAtmVclRateExtParam13
OBJECT-TYPE
This field is used to describe the thirteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.13Integer32read-writecurrent
zhoneAtmVclRateExtParam14
OBJECT-TYPE
This field is used to describe the fouthteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.14Integer32read-writecurrent
zhoneAtmVclRateExtParam15
OBJECT-TYPE
This field is used to describe the fifteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.15Integer32read-writecurrent
zhoneAtmVclRateExtParam16
OBJECT-TYPE
This field is used to describe the sixteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.16Integer32read-writecurrent
zhoneAtmVclRateExtParam1Grp2
OBJECT-TYPE
This field is used to describe the first least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.17Integer32read-writecurrent
zhoneAtmVclRateExtParam2Grp2
OBJECT-TYPE
This field is used to describe the second least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.18Integer32read-writecurrent
zhoneAtmVclRateExtParam3Grp2
OBJECT-TYPE
This field is used to describe the third least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.19Integer32read-writecurrent
zhoneAtmVclRateExtParam4Grp2
OBJECT-TYPE
This field is used to describe the fourth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.20Integer32read-writecurrent
zhoneAtmVclRateExtParam5Grp2
OBJECT-TYPE
This field is used to describe the fifth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.21Integer32read-writecurrent
zhoneAtmVclRateExtParam6Grp2
OBJECT-TYPE
This field is used to describe the sixth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.22Integer32read-writecurrent
zhoneAtmVclRateExtParam7Grp2
OBJECT-TYPE
This field is used to describe the seventh least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.23Integer32read-writecurrent
zhoneAtmVclRateExtParam8Grp2
OBJECT-TYPE
This field is used to describe the eighth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.24Integer32read-writecurrent
zhoneAtmVclRateExtParam9Grp2
OBJECT-TYPE
This field is used to describe the ninth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.25Integer32read-writecurrent
zhoneAtmVclRateExtParam10Grp2
OBJECT-TYPE
This field is used to describe the tenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.26Integer32read-writecurrent
zhoneAtmVclRateExtParam11Grp2
OBJECT-TYPE
This field is used to describe the eleventh least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.27Integer32read-writecurrent
zhoneAtmVclRateExtParam12Grp2
OBJECT-TYPE
This field is used to describe the twelfth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.28Integer32read-writecurrent
zhoneAtmVclRateExtParam13Grp2
OBJECT-TYPE
This field is used to describe the thirteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.29Integer32read-writecurrent
zhoneAtmVclRateExtParam14Grp2
OBJECT-TYPE
This field is used to describe the fourteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.30Integer32read-writecurrent
zhoneAtmVclRateExtParam15Grp2
OBJECT-TYPE
This field is used to describe the fifthteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.31Integer32read-writecurrent
zhoneAtmVclRateExtParam16Grp2
OBJECT-TYPE
This field is used to describe the sixthteenth least field of total 16 minimum guaranteed rate which is configurable by user for a VCL which is bound to this traffic descriptor for BAN ATM Trunk or MALC uplink Cards.
1.3.6.1.4.1.5504.4.2.2.6.32Integer32read-writecurrent
zhoneAtmVplExtTable
OBJECT-TYPE
Zhone extension table for the atmVplTable defined in rfc2515.
1.3.6.1.4.1.5504.4.2.2.7not-accessiblecurrent
zhoneAtmVplExtEntry
OBJECT-TYPE
NOT CURRENTLY IMPLEMENTED. An entry in the atmVplExtTable. atmVplExtEntry is an augmentation to the atmVplEntry defined in rfc2515.
1.3.6.1.4.1.5504.4.2.2.7.1not-accessiblecurrent
zhoneAtmVplExtFaultDetectionType
OBJECT-TYPE
NOT CURRENTLY IMPLEMENTED. This is used to configure VPL fault detection. The valid values are: * disabled - Fault detection is disabled. This is the default. * oamF4Loopback - This option uses standard OAM fault management cells as defined in ITU.610 for fault detection. Automatic loopback diagnostic cells are sent to the IAD. When fault detection is enabled, atmVplOperStatusChange notification trap is used to indicate to the NMS station that a VPL has gone down or has come back up.
1.3.6.1.4.1.5504.4.2.2.7.1.1INTEGER {disabled(1), oamF4Loopback(2)}read-createcurrent
zhoneAtmVplExtTrafficContainerIndex
OBJECT-TYPE
Index number of a PON traffic container associated with a VPL definition. NOTE: MULTIPLE VARBINDS ACROSS THE VPL TABLE AND THE VPL EXTENSI0N TABLE ARE NOT ALLOWED! It turns out that anyone trying to set just the traffic container index would inadvertantly try to create a Vpl with default settings. To set the traffic container field, the Vpl must be created first.
1.3.6.1.4.1.5504.4.2.2.7.1.2Integer32 (0..2147483647)read-createcurrent
zhoneAtmConnectionStatsTable
OBJECT-TYPE
Table which describes the allocated and available ATM connections on a Zhone device.
1.3.6.1.4.1.5504.4.2.2.8not-accessiblecurrent
zhoneAtmConnectionStatsEntry
OBJECT-TYPE
An entry based on shelf/slot which describes the total allocated and available ATM connections for that shelf/slot.
1.3.6.1.4.1.5504.4.2.2.8.1not-accessiblecurrent
zhoneAtmConnectionsAvailable
OBJECT-TYPE
The total available ATM connections for a particular shelf/slot. This number is hardware dependent. Whenever a VPI is allocated for a particular shelf/slot, the number of connections allocated for that VPI is subtracted from the total available and is returned in this value.
1.3.6.1.4.1.5504.4.2.2.8.1.1Integer32read-onlycurrent
zhoneAtmConnectionsAllocated
OBJECT-TYPE
The total allocated ATM connections for a particular shelf/slot. For a particular VPI, we calculate the number of connections allocated by the following rule: A VP Switched VPI has a Max VCI of 0 and uses 3 connections. A VC Switched VPI has a Max VCI of n (the number n is a power of 2 and is user selected) and uses n connections. The sum of all allocated connections for all VPIs on the selected shelf/slot is the number returned for this value.
1.3.6.1.4.1.5504.4.2.2.8.1.2Integer32read-onlycurrent
zhoneAtmVpiTable
OBJECT-TYPE
Table which describes attributes associated to a particular VPI. Anytime you add to, delete from or modify any entry in this table, you must reboot the card in order for these changes to take effect. The reason for this is that the APC must be re-programmed and the only way to do this is by doing a reboot. In addition, you will not be allowed to modify, create or delete any atm-vcl entry which is on the same card as the VPI until after the card has been rebooted.
1.3.6.1.4.1.5504.4.2.2.9not-accessiblecurrent
zhoneAtmVpiEntry
OBJECT-TYPE
An entry based on ifIndex/vpi (which resolves to a particular shelf/slot/port/subport/type/vpi) which contains the maximum VCI value and the switch mode (either vp or vc switched) for a particular VPI.
1.3.6.1.4.1.5504.4.2.2.9.1not-accessiblecurrent
zhoneAtmVpiMaxVci
OBJECT-TYPE
For the selected VPI, this value contains the maximum VCI. For vp switched VPIs, this value must be zero. For vc switched VPIs, this value must be a power of 2 with its maximum value being hardware dependent.
1.3.6.1.4.1.5504.4.2.2.9.1.1Integer32read-writecurrent
zhoneAtmVpiSwitched
OBJECT-TYPE
For the selected VPI, this value can be set to either vp switched or vc switched. If it is vp switched, then the max vci must be zero. If it is vc switched, the max vci value must be a power of 2 with its maximum value being hardware dependent.
1.3.6.1.4.1.5504.4.2.2.9.1.2INTEGER {vp(1), vc(2)}read-writecurrent
zhoneAtmVpiRowStatus
OBJECT-TYPE
Row Status only supports create-and-go and destroy actions. Returns active if row is in service.
1.3.6.1.4.1.5504.4.2.2.9.1.3ZhoneRowStatusread-createcurrent
zhoneAtmVpiOamF4Ping
OBJECT-TYPE
This is used to send a OAM F4 loopback cell for fault detection. The value will automatically revert to disabled after the set is complete. The valid values are: * disabled - OAM F4 loopback cell is not being sent. This is the default. * endToEnd - This option uses standard OAM fault management cells as defined in ITU.610 for fault detection. Setting this will send a OAM F4 end-to-end loopback cell to be sent * segment - This is not supported at this time
1.3.6.1.4.1.5504.4.2.2.9.1.4INTEGER {disabled(1), endToEnd(2), segment(3)}read-writecurrent
zhoneAtmVpiOamF4PingStatus
OBJECT-TYPE
TRUE if ping was successfull and FALSE if failed.
1.3.6.1.4.1.5504.4.2.2.9.1.5TruthValueaccessible-for-notifycurrent
zhoneAtmVpiMaxVciPerVp
OBJECT-TYPE
If vp-switched, but VG connection is vc-switched, this specifies max number of vci on gateway.
1.3.6.1.4.1.5504.4.2.2.9.1.6Integer32read-writecurrent
atmVpi
OBJECT-TYPE
VPI used for traps defined under atm traps
1.3.6.1.4.1.5504.4.2.2.10AtmVpIdentifieraccessible-for-notifycurrent
atmVci
OBJECT-TYPE
VCI used for traps defined under atm traps
1.3.6.1.4.1.5504.4.2.2.11AtmVcIdentifieraccessible-for-notifycurrent
atmVpiAutoCreateDone
OBJECT-TYPE
Indicates automatic Vpi generation complete.
1.3.6.1.4.1.5504.4.2.2.12TruthValueaccessible-for-notifycurrent
atmVpiAutoCreateCount
OBJECT-TYPE
This value is the count of the number of auto-created Vpis.
1.3.6.1.4.1.5504.4.2.2.13Integer32accessible-for-notifycurrent
atmVclToMulticastMap
OBJECT-IDENTITY
1.3.6.1.4.1.5504.4.2.2.16
atmVclToMulticastMapIndexNext
OBJECT-TYPE
This object contains an appropriate value to be used for atmMulticastAddressVclMapIndex when creating entries in the atmMulticastAddressVclMapTable. The value 0 indicates that no unassigned entries are available. To obtain the atmMulticastAddressVclMapIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
1.3.6.1.4.1.5504.4.2.2.16.1INTEGER (0..65535)read-onlycurrent
atmVclToMulticastMapTable
OBJECT-TYPE
The Multicast Address to Vcl Mapping table. Each entry in this table associates a multicast address representing a video stream with a Vcl. All of the entries in this table are assumed to be unique, not only in terms of index, but in terms of (index, multicast address) <-> (ifIndex, vpi, vci). Note that the Vcl type for this table should always be 'other', denoting cell relay pass-through. We are not terminating the IP stream on the MALC. Also note that the Vcls that this table refer to are the ones originating at the Video Head-End, coming into the MALC Uplink card.
1.3.6.1.4.1.5504.4.2.2.16.2not-accessiblecurrent
atmVclToMulticastMapEntry
OBJECT-TYPE
An entry in the Multicast Address to Vcl Mapping table. This entry is used to associate a multicast address with a Vcl. Step-wise Procedures to set up a Multicast Vcl Mapping profile Once the Vcl that carries the video stream is created, the following steps are taken to provision a Multicast Address to Vcl Mapping: (1) The manager obtains a unique atmMulticastAddressVclMapIndex by reading the atmMulticastAddressVclMapIndexNext object. (2) Next, the manager creates a row in the atmMulticastAddressVclMapTable by setting atmMulticastAddressVclMapRowStatus to createAndGo. The agent checks the sanity of the Vcl, domain index, and multicast address. The row creation fails if: - the specified Vcl does not exist, - the specified Vcl is not of the correct type for multicasting, - the routing domain index is outside of the supported range, - the multicast address is not of the correct format. (3) The manager promotes the row in the atmMulticastAddressVclMapTable when the 'set' completes.
1.3.6.1.4.1.5504.4.2.2.16.2.1not-accessiblecurrent
atmVclToMulticastMapIndex
OBJECT-TYPE
A unique value to identify this Multicast Address to Vcl mapping.
1.3.6.1.4.1.5504.4.2.2.16.2.1.1INTEGER (1..65535)not-accessiblecurrent
atmVclToMulticastMapRoutingDomain
OBJECT-TYPE
Routing domain of the Head-End video server.
1.3.6.1.4.1.5504.4.2.2.16.2.1.2INTEGER (0..65535)read-createcurrent
atmVclToMulticastMapMulticastAddress
OBJECT-TYPE
Multicast IP address contained in the MPEG2 video stream.
1.3.6.1.4.1.5504.4.2.2.16.2.1.3IpAddressread-createcurrent
atmVclToMulticastMapIfIndex
OBJECT-TYPE
The ifIndex value of the ATM interface for the Vcl carrying a video stream.
1.3.6.1.4.1.5504.4.2.2.16.2.1.4InterfaceIndexread-createcurrent
atmVclToMulticastMapVpi
OBJECT-TYPE
The VPI value of the ATM interface for the Vcl carrying a video stream.
1.3.6.1.4.1.5504.4.2.2.16.2.1.5AtmVpIdentifierread-createcurrent
atmVclToMulticastMapVci
OBJECT-TYPE
The VCI value of the ATM interface for the Vcl carrying a video stream.
1.3.6.1.4.1.5504.4.2.2.16.2.1.6AtmVcIdentifierread-createcurrent
atmVclToMulticastMapRowStatus
OBJECT-TYPE
Row status of the multicast address to Vcl table entry. This object must be initially set to 'createAndGo'.
1.3.6.1.4.1.5504.4.2.2.16.2.1.7ZhoneRowStatusread-createcurrent
zhoneAtmPonExtTable
OBJECT-TYPE
This is the Zhone extension to the Atm Vcl Table (rfc2515.) It contains APON-related objects.
1.3.6.1.4.1.5504.4.2.2.17not-accessibledeprecated
zhoneAtmPonExtEntry
OBJECT-TYPE
This is an entry in the Atm PON Extension table.
1.3.6.1.4.1.5504.4.2.2.17.1not-accessibledeprecated
zhoneAtmVclPonTrafficContainerIndex
OBJECT-TYPE
This field is an index into the ATM PON Traffic Container table. It associated a Vcl with a Traffic Container, and is used to retrieve PON channel provisioning information.
1.3.6.1.4.1.5504.4.2.2.17.1.1Integer32 (0..65535)read-createdeprecated
zhoneAtmVplPonExtTable
OBJECT-TYPE
This is the Zhone extension to the Atm Vpl Table (rfc2515.) It contains APON-related objects.
1.3.6.1.4.1.5504.4.2.2.18not-accessibledeprecated
zhoneAtmVplPonExtEntry
OBJECT-TYPE
This is an entry in the Atm PON Extension table.
1.3.6.1.4.1.5504.4.2.2.18.1not-accessibledeprecated
zhoneAtmVplPonTrafficContainerIndex
OBJECT-TYPE
This field is an index into the ATM PON Traffic Container table. It associated a Vpl with a Traffic Container, and is used to retrieve PON channel provisioning information.
1.3.6.1.4.1.5504.4.2.2.18.1.1Integer32 (0..2147483647)read-createdeprecated
zhoneAtmInterfaceTcExtTable
OBJECT-TYPE
This table contains ATM interface TC Sublayer parameters and state variables, one entry per ATM interface port.
1.3.6.1.4.1.5504.4.2.2.19not-accessiblecurrent
zhoneAtmInterfaceTcExtEntry
OBJECT-TYPE
This list contains TC Sublayer parameters and state variables at the ATM interface and is indexed by the ifIndex value of the ATM interface.
1.3.6.1.4.1.5504.4.2.2.19.1not-accessiblecurrent
zhoneAtmInterfaceNCDEvents
OBJECT-TYPE
The number of times the Near-end No Cell Delineation (NCD) events occur.
1.3.6.1.4.1.5504.4.2.2.19.1.1Counter32read-onlycurrent
zhoneAtmInterfaceHECEvents
OBJECT-TYPE
The number of times Near-end Header Error Control (HEC) violations occur.
1.3.6.1.4.1.5504.4.2.2.19.1.2Counter32read-onlycurrent
zhoneAtmInterfaceFeOCDEvents
OBJECT-TYPE
The number of times Far-end Out of Cell Delineation (OCD) events occur.
1.3.6.1.4.1.5504.4.2.2.19.1.3Counter32read-onlycurrent
zhoneAtmInterfaceFeNCDEvents
OBJECT-TYPE
The number of times Far-end No Cell Delineation (NCD) events occur.
1.3.6.1.4.1.5504.4.2.2.19.1.4Counter32read-onlycurrent
zhoneAtmInterfaceFeHECEvents
OBJECT-TYPE
The number of times Far-end Header Error Control (HEC) violations occur.
1.3.6.1.4.1.5504.4.2.2.19.1.5Counter32read-onlycurrent
zhoneAtmVcCrossConnectExtTable
OBJECT-TYPE
This Table contains Atm Vc Cross Connect Extensions to the atmVcCrossConnectEntry.
1.3.6.1.4.1.5504.4.2.2.20not-accessiblecurrent
zhoneAtmVcCrossConnectExtEntry
OBJECT-TYPE
This list contains Atm Vc Cross Connect Extensions to the atmVcCrossConnectEntry.
1.3.6.1.4.1.5504.4.2.2.20.1not-accessiblecurrent
zhoneAtmVcCrossConnectExtHandleId
OBJECT-TYPE
An administratively-assigned name for the Atm Vc Cross Connect indicated by the INDEX value.
1.3.6.1.4.1.5504.4.2.2.20.1.1OCTET STRING (SIZE(1..16))read-createcurrent

Notifications

NameOIDStatus
atmVclOperStatusChange
NOTIFICATION-TYPE
A notification is sent when the operational status of an ATM VCL changes. The VCL entity is identified by its ifIndex, VPI and VCI values in the trap instance OIDs.
1.3.6.1.4.1.5504.4.2.2.2.0.1current
atmDsx3PlcpAlarmStatusChange
NOTIFICATION-TYPE
This trap indicates if there is an alarm present for the DS3 PLCP.
1.3.6.1.4.1.5504.4.2.2.2.0.2current
atmInterfaceTCAlarmStateChange
NOTIFICATION-TYPE
This trap indicates that there is an alarm present for the TC Sublayer.
1.3.6.1.4.1.5504.4.2.2.2.0.3current
atmVclBandwidthUnavailable
NOTIFICATION-TYPE
This trap indicates that guranteed bandwidth specified by zhoneAtmTrafficDescrParamExtTrnkVclRate in the traffic descriptor is not available in the system. This is sent when a VCL is activated with the traffic descriptor which specifies higher than available rate or a VCL is activated with the traffic descriptor which specifies the vcl-rate value which can cause available bandwidth to run out. In this trap, shelf/slot is sent as part of the common fields sent in all traps.
1.3.6.1.4.1.5504.4.2.2.2.0.4current
atmVplOperStatusChange
NOTIFICATION-TYPE
Description.
1.3.6.1.4.1.5504.4.2.2.2.0.5current
atmOamF5PingStatus
NOTIFICATION-TYPE
A notification is sent when the OAM F5 Ping succeeds or fails. The entity is identified by its ifIndex, VPI and VCI values in the trap instance OIDs. A status value of true indicates successful Ping, otherwise unsuccessful Ping.
1.3.6.1.4.1.5504.4.2.2.2.0.6current
atmVpiAutoCreateComplete
NOTIFICATION-TYPE
Notification indicating Vpi auto creation is complete.
1.3.6.1.4.1.5504.4.2.2.2.0.7current
atmOamF4PingStatus
NOTIFICATION-TYPE
A notification is sent when the OAM F4 Ping succeeds or fails. The entity is identified by its ifIndex, and VPI values in the trap instance OIDs. A status value of true indicates successful Ping, otherwise unsuccessful Ping.
1.3.6.1.4.1.5504.4.2.2.2.0.8current
atmVclExtOamF4PingStatus
NOTIFICATION-TYPE
A notification is sent when the VCL OAM F4 Ping succeeds or fails. The entity is identified by its ifIndex, vpi and vci values in the trap instance OIDs. zhoneAtmVclExtOamF4PingStatus value of true indicates successful Ping, otherwise unsuccessful Ping.
1.3.6.1.4.1.5504.4.2.2.2.0.9current

Conformance

NameOIDStatus
zhoneAtmVclExtGroup
OBJECT-GROUP
A collection of objects contained in the zhoneAtmVclExtTable.
1.3.6.1.4.1.5504.4.2.2.3.1current
zhoneAtmTrapsGroup
NOTIFICATION-GROUP
A collection of notification traps under the zhoneAtmV2Traps.
1.3.6.1.4.1.5504.4.2.2.3.2current
zhoneAtmTrafficDescrParamExtGroup
OBJECT-GROUP
A collection of objects contained in the zhoneAtmTrafficDescrParamExtTable.
1.3.6.1.4.1.5504.4.2.2.3.3current
zhoneAtmStatsExtTableGroup
OBJECT-GROUP
Description.
1.3.6.1.4.1.5504.4.2.2.3.4current
zhoneAtmVclRateExtParamGroup
OBJECT-GROUP
Atm Vcl rate parameter values.
1.3.6.1.4.1.5504.4.2.2.3.5current
zhoneAtmVplExtGroup
OBJECT-GROUP
Description.
1.3.6.1.4.1.5504.4.2.2.3.6current
zhoneAtmConnectionStatsGroup
OBJECT-GROUP
Description.
1.3.6.1.4.1.5504.4.2.2.3.7current
zhoneAtmVpiGroup
OBJECT-GROUP
Description.
1.3.6.1.4.1.5504.4.2.2.3.8current
zhoneAtmPonGroup
OBJECT-GROUP
Description.
1.3.6.1.4.1.5504.4.2.2.3.9deprecated
zhoneAtmVclMulticastGroup
OBJECT-GROUP
Description.
1.3.6.1.4.1.5504.4.2.2.3.10current