ZHNSYSMON
- Registered at
- 1.3.6.1.4.1.5504.2.5.1
- Last updated
- 2010-09-24 00:00
- Organization
- Zhone Technologies MIB Working Group Other information about group editing the MIB
- Revisions
- 2010-09-24 00:00, 2010-06-21 00:00, 2009-12-14 00:00, 2009-05-20 00:00, 2009-04-06 00:00, 2009-01-06 00:00, 2008-05-21 00:00, 2007-11-26 00:00, 2006-12-26 00:00, 2006-12-12 00:00, 2006-11-17 00:00, 2006-08-31 00:00
- Namespace
- zhone
- Source file
ZHNSYSMON- Digest
sha256:c7635222230da28583d963693e1dc39221297999292ac3e8ebd8f91a5933a6c4
Description
This MIB contains objects that are used by the System Monitoring function. ============================================================== == == == Copyright (C) 2007-2010 Zhone Technologies, Inc. == == == ==============================================================
Contact
Zhone Technologies, Inc. Florida Design Center 8545 126th Avenue North Largo, FL 33773 www.zhone.com General Comments to: largo-mibwg-team@zhone.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION |
| Zhone | zhoneWtn |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC ZHNSYSMON Zhone
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| zhnSysMonNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.5504.2.5.1.0 | |||
| zhnSysMonObjects OBJECT-IDENTITY | 1.3.6.1.4.1.5504.2.5.1.1 | |||
| zhnSysMonAlarmTable OBJECT-TYPE This table contains the current system alarms. | 1.3.6.1.4.1.5504.2.5.1.1.1 | not-accessible | current | |
| zhnSysMonAlarmEntry OBJECT-TYPE An entry in the zhnSysMonAlarmTable. | 1.3.6.1.4.1.5504.2.5.1.1.1.1 | not-accessible | current | |
| zhnSysMonAlarmType OBJECT-TYPE The type of alarm currently posted. | 1.3.6.1.4.1.5504.2.5.1.1.1.1.1 | INTEGER {tempThresholdExceeded(1), mainPowerLoss(2), secondaryPowerLoss(3), lowPowerMode(4), selftestFailed(5), interfaceDown(6), processFailed(7), pwDown(8), pwDeleted(9), pwMisconnected(10), pwLOP(11), pwLateFrame(12), pwMalformedFrame(13), pwJitterBufferOverrun(14), dsx1RcvYellow(15), dsx1XmtYellow(16), dsx1RcvAIS(17), dsx1XmtAIS(18), dsx1LossOfFrame(19), dsx1LossOfSignal(20), dsx1LoopbackState(21), dsx1TestingState(22), pwClockStability(23), pwClockHoldover(24), pwClockStabilityIdle(25), pwClockStabilityAcquisition(26), pwClockStabilityTracking1(27), pwClockStabilityRecovery(28), onBatteryPower(29), batteryPowerLow(30), replaceBattery(31), batteryRemoved(32), onBatteryPower2(33), batteryPowerLow2(34), replaceBattery2(35), batteryRemoved2(36), doorOpened(37), other(99)} | read-create | current |
| zhnSysMonAlarmSeverity OBJECT-TYPE The severity of the alarm. | 1.3.6.1.4.1.5504.2.5.1.1.1.1.2 | INTEGER {minor(1), major(2), critical(3), wanData(4)} | read-create | current |
| zhnSysMonAlarmInterfaceName OBJECT-TYPE This object specifies the interface name (e.g., wlan0), or instance (e.g., sensor 1, primary power source 3) associated with the alarm. | 1.3.6.1.4.1.5504.2.5.1.1.1.1.3 | DisplayString (SIZE(1..255)) | read-create | current |
| zhnSysMonAlarmDescription OBJECT-TYPE This object is a textual description of an alarm type. | 1.3.6.1.4.1.5504.2.5.1.1.1.1.4 | DisplayString (SIZE(1..255)) | read-create | current |
| zhnSysMonAlarmRowStatus OBJECT-TYPE The SNMP RowStatus of the current row. | 1.3.6.1.4.1.5504.2.5.1.1.1.1.5 | RowStatus | read-create | current |
| zhnSysMonTestTable OBJECT-TYPE This table contains the current system tests. | 1.3.6.1.4.1.5504.2.5.1.1.2 | not-accessible | current | |
| zhnSysMonTestEntry OBJECT-TYPE An entry in the zhnSysMonTestTable. | 1.3.6.1.4.1.5504.2.5.1.1.2.1 | not-accessible | current | |
| zhnSysMonTestType OBJECT-TYPE The type of test currently running. | 1.3.6.1.4.1.5504.2.5.1.1.2.1.1 | INTEGER {loopback(1), led(2)} | read-create | current |
| zhnSysMonTestInterfaceName OBJECT-TYPE This object specifies the interface name (e.g., wlan0) associated with the test. | 1.3.6.1.4.1.5504.2.5.1.1.2.1.2 | DisplayString (SIZE(1..255)) | read-create | current |
| zhnSysMonTestRowStatus OBJECT-TYPE The SNMP RowStatus of the current row. | 1.3.6.1.4.1.5504.2.5.1.1.2.1.3 | RowStatus | read-create | current |
| zhnSysMonTempSensorTable OBJECT-TYPE This table contains the system temperature sensors. | 1.3.6.1.4.1.5504.2.5.1.1.3 | not-accessible | current | |
| zhnSysMonTempSensorEntry OBJECT-TYPE An entry in the zhnSysMonTempSensorTable. | 1.3.6.1.4.1.5504.2.5.1.1.3.1 | not-accessible | current | |
| zhnSysMonTempSensorId OBJECT-TYPE This object specifies the reference index for each detected temperature sensor. | 1.3.6.1.4.1.5504.2.5.1.1.3.1.1 | Unsigned32 (0..9999) | read-create | current |
| zhnSysMonTempSensorRowStatus OBJECT-TYPE The SNMP RowStatus of the current row. | 1.3.6.1.4.1.5504.2.5.1.1.3.1.2 | RowStatus | read-create | current |
| zhnSysMonTempSensorCurr OBJECT-TYPE The current temperature reported by the sensor in degrees Celcius. | 1.3.6.1.4.1.5504.2.5.1.1.3.1.3 | DisplayString (SIZE(1..8)) | read-only | current |
| zhnSysMonTempSensorOS OBJECT-TYPE The configured Overtemperature Shutdown (OS) for the sensor in degrees Celcius. This is the temperature alarm threshold | 1.3.6.1.4.1.5504.2.5.1.1.3.1.4 | DisplayString (SIZE(1..8)) | read-write | current |
| zhnSysMonTempSensorHyst OBJECT-TYPE The configured temperature hysteresis for the sensor in degrees Celcius. This is the temperature at which the alarm condition goes away. | 1.3.6.1.4.1.5504.2.5.1.1.3.1.5 | DisplayString (SIZE(1..8)) | read-write | current |
| zhnSysMonTempSensorName OBJECT-TYPE A textual string describing the sensor. | 1.3.6.1.4.1.5504.2.5.1.1.3.1.6 | DisplayString (SIZE(0..255)) | read-write | current |
| zhnSysMonLinePowerTable OBJECT-TYPE This table contains the line power configuration. | 1.3.6.1.4.1.5504.2.5.1.1.4 | not-accessible | current | |
| zhnSysMonLinePowerEntry OBJECT-TYPE An entry in the zhnSysMonLinePowerTable. | 1.3.6.1.4.1.5504.2.5.1.1.4.1 | not-accessible | current | |
| zhnSysMonLinePowerLineNumber OBJECT-TYPE This object specifies the line number for each primary power source. | 1.3.6.1.4.1.5504.2.5.1.1.4.1.1 | Unsigned32 (1..9999) | read-create | current |
| zhnSysMonLinePowerStatus OBJECT-TYPE The current power configuration status of the line identified by zhnSysMonLinePowerLineNumber. A status of enabled(1) indicates that the line is being monitored as a primary power source for the unit (i.e., an alarm is posted if it fails). | 1.3.6.1.4.1.5504.2.5.1.1.4.1.2 | INTEGER {enabled(1), disabled(2)} | read-create | current |
| zhnSysMonLinePowerRowStatus OBJECT-TYPE The SNMP RowStatus of the current row. | 1.3.6.1.4.1.5504.2.5.1.1.4.1.3 | RowStatus | read-create | current |
| zhnSysMonConformance OBJECT-IDENTITY | 1.3.6.1.4.1.5504.2.5.1.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| zhnSysMonAlarmSetEvent NOTIFICATION-TYPE A zhnSysMonAlarmSetEvent notification is sent when an alarm condition is detected by a system component. The System Monitor is informed of the alarm and generates the alarm set notification. The objects in the notification correspond to the values in a row instance of in the zhnSysMonAlarmTable. | 1.3.6.1.4.1.5504.2.5.1.0.1 | current |
| zhnSysMonAlarmClearEvent NOTIFICATION-TYPE A zhnSysMonAlarmClearEvent notification is sent when an alarm condition is cleared by a system component. The System Monitor is informed of the alarm state and generates the alarm clear notification. The objects in the notification correspond to the values in a row instance of in the zhnSysMonAlarmTable. | 1.3.6.1.4.1.5504.2.5.1.0.2 | current |
| zhnSysMonTestStartEvent NOTIFICATION-TYPE A zhnSysMonTestStartEvent notification is sent by any system component that begins a test. The objects in the notification correspond to the values in a row instance of in the zhnSysMonTestTable. | 1.3.6.1.4.1.5504.2.5.1.0.3 | current |
| zhnSysMonTestStopEvent NOTIFICATION-TYPE A zhnSysMonTestStopEvent notification is sent by any system component that ends a test. The objects in the notification correspond to the values in a row instance of in the zhnSysMonTestTable. | 1.3.6.1.4.1.5504.2.5.1.0.4 | current |
| zhnSysMonTempSensorCfgUpdateEvent NOTIFICATION-TYPE A zhnSysMonTempCfgUpdateEvent notification is sent by the System Monitor whenever it reconfigures a temperature sensor. The objects in the notification correspond to the values in a row instance of in the zhnSysMonTempSensorTable. | 1.3.6.1.4.1.5504.2.5.1.0.5 | current |
| zhnSysMonLinePowerCfgUpdateEvent NOTIFICATION-TYPE A zhnSysMonLinePowerCfgUpdateEvent notification is sent by the System Monitor whenever it reconfigures a power source line. The objects in the notification correspond to the values in a row instance of in the zhnSysMonLinePowerTable. | 1.3.6.1.4.1.5504.2.5.1.0.6 | current |
| zhnSysMonReadyEvent NOTIFICATION-TYPE A zhnSysMonReadyEvent notification is sent by the System Monitor whenever it has completed initialization and is ready to accept requests. | 1.3.6.1.4.1.5504.2.5.1.0.7 | current |
| zhnSysMonConfigChangeEvent NOTIFICATION-TYPE A zhnSysMonConfigChangeEvent notification is generated whenever the persistent database is saved. | 1.3.6.1.4.1.5504.2.5.1.0.8 | current |