MIBs Depot

VPWR-DC-POWER-MIB

Last updated
1903-02-08 00:00
Organization
Valere Power Inc.
Namespace
eltek
Source file
VPWR-DC-POWER-MIB
Digest
sha256:1ccbb8b6a4e6079aa41a876d7d3722b0de3c797743c5bd4a7209df72ff7d3764

Description

MIB Version 2.0 History Apr 26, 2007 Added SysAlarm Config Table Version 2.0 Feb 08, 2003 Changed vpwrTrapDestinationTable to vpwrTrapTable Corrected entry for vpwrTrapTable to be VpwrTrapTableEntry This fixes errors generated by MG-SOFT mib compiler.Ver1.0 Oct 30, 2002 initial release - version 0.4

Contact

Author: Haluk Aral Contact: Customer Support Group Postal: 661 N. Plano Road, Suite 300 Richardson, TX-75081 Web: http://www.valerepower.com email: tech.support@valerepower.com Phone 866-240-6614

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-MIBsysUpTime
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCAutonomousType, DisplayString, TEXTUAL-CONVENTION, TestAndIncr, TimeInterval, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
VPWR-DC-POWER-MIB

Textual conventions

NameOIDSyntaxAccessStatus
NonNegativeInteger
TEXTUAL-CONVENTION
This data type is a non-negative value.
current
PositiveInteger
TEXTUAL-CONVENTION
This data type is a non-zero and non-negative value.
current

Objects

NameOIDSyntaxAccessStatus
vpwrDcPowerProducts
OBJECT-IDENTITY
1.3.6.1.4.1.13858.1
vpwrDcPowerSystem
OBJECT-IDENTITY
1.3.6.1.4.1.13858.2
vpwrSystemIdentGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.2.1
vpwrIdentManufacturer
OBJECT-TYPE
The name of the DC Power manufacturer.
1.3.6.1.4.1.13858.2.1.1DisplayString (SIZE(0..31))read-onlycurrent
vpwrIdentModel
OBJECT-TYPE
The DC Power Model designation.
1.3.6.1.4.1.13858.2.1.2DisplayString (SIZE(0..15))read-onlycurrent
vpwrIdentControllerVersion
OBJECT-TYPE
The hardware/firmware version(s). This variable may or may not have the same value as vpwrIdentAgentSoftwareVersion.
1.3.6.1.4.1.13858.2.1.3DisplayString (SIZE(0..15))read-onlycurrent
vpwrIdentAgentSoftwareVersion
OBJECT-TYPE
The SNMP agent software version. This variable may or may not have the same value as vpwrIdentControllerFirmwareVersion.
1.3.6.1.4.1.13858.2.1.4DisplayString (SIZE(0..15))read-onlycurrent
vpwrIdentName
OBJECT-TYPE
A string identifying the system. This object should be set by the administrator.
1.3.6.1.4.1.13858.2.1.5DisplayString (SIZE(0..31))read-writecurrent
vpwrSystemIdentTable
OBJECT-TYPE
This table describes shelves and modules that make up the sysetm.
1.3.6.1.4.1.13858.2.1.6not-accessiblecurrent
vpwrSystemIdentEntry
OBJECT-TYPE
An entry containing information applicable to a particular module making up the system.
1.3.6.1.4.1.13858.2.1.6.1not-accessiblecurrent
vpwrShelfIndex
OBJECT-TYPE
Identifies shelf number that this module belongs to. The possible values are 1 through 16 limited by vpwrSystemShelfCapacity. The shelf that contains the controller is identified as shelf number 1.
1.3.6.1.4.1.13858.2.1.6.1.1PositiveIntegerread-onlycurrent
vpwrModuleIndex
OBJECT-TYPE
This object identifies the module by its position in the shelf. Module numbering starts from the controller/expansion controller end of the shelf. So, the module in the first slot has an index of 1, the next module is 2 and so on. Under the current scheme - Rectifier module can have a number between 1 and 5. - LVD module starts with an index of 6.
1.3.6.1.4.1.13858.2.1.6.1.2PositiveIntegerread-onlycurrent
vpwrModuleOID
OBJECT-TYPE
It indicates the type of the module by specifiying its OID
1.3.6.1.4.1.13858.2.1.6.1.3OBJECT IDENTIFIERread-onlycurrent
vpwrModuleParameter
OBJECT-TYPE
The meaning of this object depends upon the module type which is indicated by vpwrModuleOID as follows - Current for Rectifier module. - Not Applicable for LVD module
1.3.6.1.4.1.13858.2.1.6.1.4INTEGERread-onlycurrent
vpwrModuleOperStatus
OBJECT-TYPE
This object indicates current over all status of the module.
1.3.6.1.4.1.13858.2.1.6.1.5INTEGER {moduleStatusOK(0), moduleStatusAlarm(1)}read-onlycurrent
vpwrModuleCapacity
OBJECT-TYPE
The meaning of this object depends upon the module type which is indicated by vpwrModuleOID as follows - Capacity for Rectifier module. - Not Applicable for LVD module
1.3.6.1.4.1.13858.2.1.6.1.6INTEGERread-onlycurrent
vpwrSystemConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.2.2
vpwrSystemTempCompensation
OBJECT-TYPE
This parameter enables/disables temperature compensation.
1.3.6.1.4.1.13858.2.2.1INTEGER {tempCompDisabled(0), tempCompEnabled(1)}read-writecurrent
vpwrSystemTempCompStartTemperature
OBJECT-TYPE
The temperature at which temperature compensation becomes active.
1.3.6.1.4.1.13858.2.2.2INTEGER (25..60)read-writecurrent
vpwrSystemTempCompStopVoltage
OBJECT-TYPE
When temperature compensation is active, vpwrSystemTempCompStopVoltage is the limit to which float voltage will be reduced. For example, to set this voltage to 51.75 volts enter a value of 5175.
1.3.6.1.4.1.13858.2.2.3INTEGERread-writecurrent
vpwrSystemTempCompensationSlope
OBJECT-TYPE
The rate at which float voltage is changed, within the specified limits, when temperature compensation is active.
1.3.6.1.4.1.13858.2.2.4INTEGER (0..250)read-writecurrent
vpwrSystemThermalSenseType
OBJECT-TYPE
This parameter selects the temperature sensing point for temperature compensation (in)activation.
1.3.6.1.4.1.13858.2.2.5INTEGER {external(0), internal(1)}read-writecurrent
vpwrSystemHVAlarmSetpoint
OBJECT-TYPE
System High voltage alarm voltage setting.
1.3.6.1.4.1.13858.2.2.6INTEGERread-writecurrent
vpwrSystemBDAlarmSetpoint
OBJECT-TYPE
System Battery Discharge voltage setting.
1.3.6.1.4.1.13858.2.2.7INTEGERread-writecurrent
vpwrSystemInternalTempLThreshold
OBJECT-TYPE
Temperature value at which temperature compensation inactive (clear) trap would be sent if temperature compensation was active when this value is reached.
1.3.6.1.4.1.13858.2.2.8INTEGERread-writecurrent
vpwrSystemInternalTempUThreshold
OBJECT-TYPE
Temperature value at which temperature compensation active (set) trap would be sent.
1.3.6.1.4.1.13858.2.2.9INTEGERread-writecurrent
vpwrSystemParameterGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.2.3
vpwrSystemShelfCapacity
OBJECT-TYPE
It describes the maximum number of shelves that can/are controlled by the controller. Each shelf is uniquely numbered in the range from 1 to vpwrShelfCapacity.
1.3.6.1.4.1.13858.2.3.1INTEGER (1..16)read-onlycurrent
vpwrSystemVoltage
OBJECT-TYPE
The current system voltage.
1.3.6.1.4.1.13858.2.3.2INTEGERread-onlycurrent
vpwrSystemCurrent
OBJECT-TYPE
The current system current.
1.3.6.1.4.1.13858.2.3.3INTEGERread-onlycurrent
vpwrSystemControllerState
OBJECT-TYPE
Current System state as shown on the enhanced display.
1.3.6.1.4.1.13858.2.3.4INTEGER {systemControllerStateUnknown(0), systemControllerStateNormal(1), systemControllerStateChange(2), systemControllerStateAlarm(3), systemControllerStateMenu(4), systemControllerStateIrActive(5)}read-onlycurrent
vpwrSystemInternalTemperature
OBJECT-TYPE
The current controller internal temperature.
1.3.6.1.4.1.13858.2.3.5INTEGERread-onlycurrent
vpwrSystemTempCompensationState
OBJECT-TYPE
Active or Inactive. Applicable only if temperature compensation is enabled. This means that the controller is temperature compensating the float voltage.
1.3.6.1.4.1.13858.2.3.6INTEGER {systemTempCompInactive(0), systemTempCompActive(1)}read-onlycurrent
vpwrSystemType
OBJECT-TYPE
This parameter describes the type of the system being managed. This object is set by Valere Power Inc.
1.3.6.1.4.1.13858.2.3.7INTEGER {sysType48V(0), sysType24V(1)}read-onlycurrent
vpwrDcPowerRectifier
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3
vpwrRectifierConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.1
vpwrRectifierFVSetpoint
OBJECT-TYPE
System Float Voltage setting
1.3.6.1.4.1.13858.3.1.1INTEGERread-writecurrent
vpwrRectifierHVSDSetpoint
OBJECT-TYPE
System High Voltage Shutdown voltage setting
1.3.6.1.4.1.13858.3.1.2INTEGERread-writecurrent
vpwrRectifierAlarmGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2
vpwrRectAlarmDCFail
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.1current
vpwrRectAlarmBoostFail
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.2current
vpwrRectAlarmACFail
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.3current
vpwrRectAlarmHVSD
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.4current
vpwrRectAlarmFanFail
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.5current
vpwrRectAlarmAmbTemp
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.6current
vpwrRectAlarmIntTemp
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.7current
vpwrRectAlarmIShare
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.8current
vpwrRectAlarmUV
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.9current
vpwrRectAlarmLowVoltage
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.10current
vpwrRectAlarmReserved
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.11current
vpwrRectAlarmDCEnable
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.12current
vpwrRectAlarmRemoteShutdown
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.13current
vpwrRectAlarmModDisableShutdown
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.14current
vpwrRectAlarmShortPinShutdown
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.15current
vpwrRectAlarmBoostComm
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.2.16current
vpwrRectifierTestGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.3.3
vpwrDcPowerLvd
OBJECT-IDENTITY
1.3.6.1.4.1.13858.4
vpwrLvdConfigGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.4.1
vpwrLvdWarningSetpoint
OBJECT-TYPE
LVD Warning voltage setpoint.
1.3.6.1.4.1.13858.4.1.1INTEGERread-writecurrent
vpwrLvdDisconnectSetpoint
OBJECT-TYPE
LVD disconnect voltage setpoint.
1.3.6.1.4.1.13858.4.1.2INTEGERread-writecurrent
vpwrLvdReconnectSetpoint
OBJECT-TYPE
LVD Reconnect voltage setpoint.
1.3.6.1.4.1.13858.4.1.3INTEGERread-writecurrent
vpwrLvdReconnectDelayTimer
OBJECT-TYPE
The delay time, in seconds, before LVD is reconnected
1.3.6.1.4.1.13858.4.1.4INTEGER (20..240)read-writecurrent
vpwrLvdAlarmGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.4.2
vpwrLvdAlarmContactorOpen
OBJECT-IDENTITY
Contactor open
1.3.6.1.4.1.13858.4.2.1current
vpwrLvdAlarmCBOpen
OBJECT-IDENTITY
Circuit Breaker open
1.3.6.1.4.1.13858.4.2.2current
vpwrTrapLvdFuseOpen
OBJECT-IDENTITY
Fuse open
1.3.6.1.4.1.13858.4.2.3current
vpwrLvdAlarmWarning
OBJECT-IDENTITY
Plant Voltage below warning threshold
1.3.6.1.4.1.13858.4.2.4current
vpwrLvdTestGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.4.3
vpwrDcPowerTest
OBJECT-IDENTITY
1.3.6.1.4.1.13858.5
vpwrDcPowerModuleIdent
OBJECT-IDENTITY
1.3.6.1.4.1.13858.6
vpwrDcPowerBatteryGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.7
vpwrBatteryTempGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.7.1
vpwrBatteryTempTable
OBJECT-TYPE
This table describes battery temperature probes.
1.3.6.1.4.1.13858.7.1.1not-accessiblecurrent
vpwrBatteryTempTableEntry
OBJECT-TYPE
An entry containing information applicable to a particular temperature probe.
1.3.6.1.4.1.13858.7.1.1.1not-accessiblecurrent
vpwrBatteryTempIndex
OBJECT-TYPE
Index into temperature table
1.3.6.1.4.1.13858.7.1.1.1.1INTEGERread-onlycurrent
vpwrBatteryTempName
OBJECT-TYPE
A string identifying probe location.
1.3.6.1.4.1.13858.7.1.1.1.2DisplayString (SIZE(1..8))read-writecurrent
vpwrBatteryTemp
OBJECT-TYPE
Current temperature as recorded by the probe.
1.3.6.1.4.1.13858.7.1.1.1.3INTEGERread-onlycurrent
vpwrBatteryTempLThreshold
OBJECT-TYPE
Temperature value at which a clear trap would be sent. All three battery temperature must be at or below this value to trigger this trap.
1.3.6.1.4.1.13858.7.1.2INTEGERread-writecurrent
vpwrBatteryTempUThreshold
OBJECT-TYPE
Temperature value at which a set trap would be sent. Any one of the three battery temperatures at or exceeding this limit would trigger the trap.
1.3.6.1.4.1.13858.7.1.3INTEGERread-writecurrent
vpwrDcPowerAlarmGroup
OBJECT-IDENTITY
1.3.6.1.4.1.13858.8
vpwrAlarmsPresent
OBJECT-TYPE
The present number of active alarm conditions.
1.3.6.1.4.1.13858.8.1Gauge32read-onlycurrent
vpwrAlarmTable
OBJECT-TYPE
A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The vpwrAlarmIndex, for each type of module starts at 1 and is limited by the total number of alarams that can be generated by the module. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), vpwrAlarmDescr, to allow a single table to reflect alarms for different type of modules. The number of rows in the table at any given time is reflected by the value of vpwrAlarmsPresent.
1.3.6.1.4.1.13858.8.2not-accessiblecurrent
vpwrAlarmEntry
OBJECT-TYPE
An entry containing information applicable to a particular alarm.
1.3.6.1.4.1.13858.8.2.1not-accessiblecurrent
vpwrAlarmIndex
OBJECT-TYPE
Identifies the alarm associated with the module. It is unique on per module type basis. For example, multiple rectifiers can have the same alarm and therefore same vpwrAlarmIndex active at any one time.
1.3.6.1.4.1.13858.8.2.1.1PositiveIntegerread-onlycurrent
vpwrAlarmDescr
OBJECT-TYPE
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.
1.3.6.1.4.1.13858.8.2.1.2AutonomousTyperead-onlycurrent
vpwrAlarmTime
OBJECT-TYPE
The value of sysUpTime when the alarm condition was detected.
1.3.6.1.4.1.13858.8.2.1.3TimeStampread-onlycurrent
sysAlarmConfigTable
OBJECT-TYPE
This table describes battery temperature probes.
1.3.6.1.4.1.13858.8.4not-accessiblecurrent
sysAlarmConfigEntry
OBJECT-TYPE
An entry containing information applicable to a particular temperature probe.
1.3.6.1.4.1.13858.8.4.1not-accessiblecurrent
sysAlarmIndex
OBJECT-TYPE
Index into temperature table
1.3.6.1.4.1.13858.8.4.1.1INTEGERread-onlycurrent
sysAlarmDefaultName
OBJECT-TYPE
A string identifying probe location.
1.3.6.1.4.1.13858.8.4.1.2DisplayString (SIZE(1..8))read-onlycurrent
sysAlarmCustomName
OBJECT-TYPE
A string identifying probe location.
1.3.6.1.4.1.13858.8.4.1.3DisplayString (SIZE(1..8))read-writecurrent
sysAlarmSeverity
OBJECT-TYPE
Alarm Severity as denoted by Major and Minor Alarm Mask
1.3.6.1.4.1.13858.8.4.1.4INTEGER {none(0), major(1), minor(2), majorAndMinor(3)}read-writecurrent
sysAlarmToRelayMapping
OBJECT-TYPE
No additional mapping = 0 Map to Relay A = 1 Map to Relay B = 2 Map to Relay C = 4 Map to Relay D = 8 Map to Relay E = 16 Map to Relay F = 32 Map to Relay A and B = (1 + 2) and so on The major/minor classification of alarms automatically associates it with Major/Minor relay. Assigning a null mapping here does not override sysRelayAlarmSeverity for the alarm. It should be used to define mapping to additional relays.
1.3.6.1.4.1.13858.8.4.1.5DisplayString (SIZE(1..8))read-writecurrent
sysAlarmOperStatus
OBJECT-TYPE
Indicates current alarm status
1.3.6.1.4.1.13858.8.4.1.6INTEGER {inactive(0), active(1)}read-onlycurrent
vpwrDcPowerSnmpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.13858.9
vpwrTrapTable
OBJECT-TYPE
A list of possible trap destinations depending upon the criticality of the trap.
1.3.6.1.4.1.13858.9.1not-accessiblecurrent
vpwrTrapTableEntry
OBJECT-TYPE
An entry containing information applicable to a particular trap destination.
1.3.6.1.4.1.13858.9.1.1not-accessiblecurrent
vpwrTrapIpIndex
OBJECT-TYPE
Trap Entry Index
1.3.6.1.4.1.13858.9.1.1.1INTEGERread-onlycurrent
vpwrTrapIpAddress
OBJECT-TYPE
Trap destination IP Address
1.3.6.1.4.1.13858.9.1.1.2IpAddressread-writecurrent
vpwrTrapCriticality
OBJECT-TYPE
Criticality of traps sent to this IP Address
1.3.6.1.4.1.13858.9.1.1.3INTEGERread-writecurrent
vpwrReadCommunityString
OBJECT-TYPE
This allows setting password to be able to do Get operations
1.3.6.1.4.1.13858.9.2DisplayString (SIZE(3..8))read-writecurrent
vpwrWriteCommunityString
OBJECT-TYPE
This allows setting password to be able to do Get and Set operations. The read-access is not allowed in the actual implementation.
1.3.6.1.4.1.13858.9.3DisplayString (SIZE(3..8))read-writecurrent
vpwrTrapCommunityString
OBJECT-TYPE
This allows setting community string required for the trap to be accepted at the destination.
1.3.6.1.4.1.13858.9.4DisplayString (SIZE(3..8))read-writecurrent
vpwrDcPowerTraps
OBJECT-IDENTITY
1.3.6.1.4.1.13858.10
vpwrDcPowerTrapsMsgString
OBJECT-IDENTITY
1.3.6.1.4.1.13858.11
vpwrTrapsMsgString
OBJECT-TYPE
Place holder for trap notification message string
1.3.6.1.4.1.13858.11.1DisplayString (SIZE(0..127))not-accessiblecurrent

Notifications

NameOIDStatus
vpwrTrapPowerMajorAlarm
NOTIFICATION-TYPE
Major Alarm
1.3.6.1.4.1.13858.10.0.1
vpwrTrapPowerMinorAlarm
NOTIFICATION-TYPE
Minor Alarm
1.3.6.1.4.1.13858.10.0.2
vpwrTrapACFAlarm
NOTIFICATION-TYPE
AC Fail Alarm
1.3.6.1.4.1.13858.10.0.3
vpwrTrapHVAlarm
NOTIFICATION-TYPE
High Voltage Warning Alarm
1.3.6.1.4.1.13858.10.0.4
vpwrTrapHVSDAlarm
NOTIFICATION-TYPE
High Voltage Shutdown Alarm
1.3.6.1.4.1.13858.10.0.5
vpwrTrapBDAlarm
NOTIFICATION-TYPE
Battery on Discharge Alarm
1.3.6.1.4.1.13858.10.0.6
vpwrTrapLVDWarningAlarm
NOTIFICATION-TYPE
LVD Warning Alarm
1.3.6.1.4.1.13858.10.0.7
vpwrTrapLVDOpenAlarm
NOTIFICATION-TYPE
LVD Open Alarm
1.3.6.1.4.1.13858.10.0.8
vpwrTrapDistAlarm
NOTIFICATION-TYPE
Distribution Open Alarm
1.3.6.1.4.1.13858.10.0.9
vpwrTrapAuxAlarm
NOTIFICATION-TYPE
Auxiliary System Alarm
1.3.6.1.4.1.13858.10.0.10
vpwrTrapSystemRedundancyAlarm
NOTIFICATION-TYPE
System Redundant Capacity Alarm
1.3.6.1.4.1.13858.10.0.11
vpwrTrapIShareAlarm
NOTIFICATION-TYPE
Rectifier Current Share Alarm
1.3.6.1.4.1.13858.10.0.12
vpwrTrapModuleFailAlarm
NOTIFICATION-TYPE
Single Rectifier Fail Alarm
1.3.6.1.4.1.13858.10.0.13
vpwrTrapMultipleModuleFailAlarm
NOTIFICATION-TYPE
Multiple Rectifier Fail Alarm
1.3.6.1.4.1.13858.10.0.14
vpwrTrapModuleCommAlarm
NOTIFICATION-TYPE
Module Communication Alarm
1.3.6.1.4.1.13858.10.0.15
vpwrTrapSystemOverTemperatureAlarm
NOTIFICATION-TYPE
System Over Temperature Alarm
1.3.6.1.4.1.13858.10.0.16
vpwrTrapSystemOK
NOTIFICATION-TYPE
SYSTEM OK - No Active Alarms
1.3.6.1.4.1.13858.10.0.17
vpwrTrapModuleInserted
NOTIFICATION-TYPE
A new module has been inserted into the system.
1.3.6.1.4.1.13858.10.0.18
vpwrTrapModuleRemoved
NOTIFICATION-TYPE
A module has been removed from the system.
1.3.6.1.4.1.13858.10.0.19
vpwrTrapThermalCompActive
NOTIFICATION-TYPE
Thermal compensation has become active.
1.3.6.1.4.1.13858.10.0.20
vpwrTrapThermalCompInactive
NOTIFICATION-TYPE
Thermal compensation has been de-activated.
1.3.6.1.4.1.13858.10.0.21
vpwrTrapInternalTempAlarmSet
NOTIFICATION-TYPE
Internal Temperature upper threshold exceeded.
1.3.6.1.4.1.13858.10.0.22
vpwrTrapInternalTempAlarmCleared
NOTIFICATION-TYPE
Internal Temperature within limits
1.3.6.1.4.1.13858.10.0.23
vpwrTrapBatteryTempAlarmSet
NOTIFICATION-TYPE
At least one Battery Temperature exceeded upper threshold.
1.3.6.1.4.1.13858.10.0.24
vpwrTrapBatteryTempAlarmCleared
NOTIFICATION-TYPE
All Battery Temperatures within limits
1.3.6.1.4.1.13858.10.0.25