MIBs Depot

VEC-MIBv5-9

Registered at
1.3.6.1.4.1.885
Last updated
2014-01-14 08:23
Organization
Emerson Energy Systems North America (ESNA)
Namespace
emerson
Source file
VEC-MIBv5-9
Digest
sha256:1457f510cca0242510828f435b3906eb7598c614c64ab49e1a9b024b455d0ac3

Description

Emerson Energy Systems North America(ESNA) VEC MIB. revision 5.9

Contact

Emerson Energy Systems North America 1510 Kansas Ave. Lorain, OH 44052 USA

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
VEC-MIBv5-9

Objects

NameOIDSyntaxAccessStatus
emersonESNA
OBJECT-IDENTITY
1.3.6.1.4.1.885
vecInformation
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.1
vecFirmwareVersion
OBJECT-TYPE
VEC System Firmware Version.
1.3.6.1.4.1.885.3.1.1DisplayStringread-onlycurrent
vecMessageStats
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.1.2
vecMessageRequests
OBJECT-TYPE
Total number of message requests.
1.3.6.1.4.1.885.3.1.2.1Integer32read-onlycurrent
vecMessageTransmissions
OBJECT-TYPE
Total number of messages transmitted.
1.3.6.1.4.1.885.3.1.2.2Integer32read-onlycurrent
vecMessageNoResponses
OBJECT-TYPE
Total number of no responses.
1.3.6.1.4.1.885.3.1.2.3Integer32read-onlycurrent
vecMessageBadCRCs
OBJECT-TYPE
Total number of bad CRC checks.
1.3.6.1.4.1.885.3.1.2.4Integer32read-onlycurrent
vecMessageLinkErrors
OBJECT-TYPE
Total number of link errors.
1.3.6.1.4.1.885.3.1.2.5Integer32read-onlycurrent
vecMessagePartialResponses
OBJECT-TYPE
Total number of partial responses received.
1.3.6.1.4.1.885.3.1.2.6Integer32read-onlycurrent
vecMessageWrongPackets
OBJECT-TYPE
Total number of wrong packet numbers detected.
1.3.6.1.4.1.885.3.1.2.7Integer32read-onlycurrent
vecMessageErrorReplies
OBJECT-TYPE
Total number of error responses received.
1.3.6.1.4.1.885.3.1.2.8Integer32read-onlycurrent
psStatus
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.2
psMeasurement
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.2.1
psSystemVoltage
OBJECT-TYPE
System Voltage.
1.3.6.1.4.1.885.3.2.1.1DisplayStringread-onlycurrent
psSystemCurrent
OBJECT-TYPE
System Current.
1.3.6.1.4.1.885.3.2.1.2Integer32read-onlycurrent
psSubsystemVoltage
OBJECT-TYPE
Sub System Voltage.
1.3.6.1.4.1.885.3.2.1.3DisplayStringread-onlycurrent
psSubsystemCurrent
OBJECT-TYPE
Sub System Current.
1.3.6.1.4.1.885.3.2.1.4Integer32read-onlycurrent
psSenseVoltage
OBJECT-TYPE
Sense Voltage.
1.3.6.1.4.1.885.3.2.1.5DisplayStringread-onlycurrent
psPCUTotalCurrent
OBJECT-TYPE
Total PCU Current.
1.3.6.1.4.1.885.3.2.1.6DisplayStringread-onlycurrent
psBatteryCurrent
OBJECT-TYPE
Total Battery Current.
1.3.6.1.4.1.885.3.2.1.7DisplayStringread-onlycurrent
psBatteryReserveHours
OBJECT-TYPE
Battery Reserve Time.
1.3.6.1.4.1.885.3.2.1.8DisplayStringread-onlycurrent
psAlarm
OBJECT-TYPE
A Power System Alarm Is Active.
1.3.6.1.4.1.885.3.2.1.9INTEGER {false(0), true(1)}read-onlycurrent
psHighestSeverityLevel
OBJECT-TYPE
The severity level is the highest active alarm level. Values: 0 = Normal, 1 = Minor, 2 = Major
1.3.6.1.4.1.885.3.2.1.10INTEGER {normal(0), minor(1), major(2)}read-onlycurrent
psNumberOfPCUsInstalled
OBJECT-TYPE
Number of PCUs installed
1.3.6.1.4.1.885.3.2.1.11Integer32 (0..80)read-onlycurrent
psNumberOfPCUsCommunicating
OBJECT-TYPE
Number of PCUs communicating
1.3.6.1.4.1.885.3.2.1.12Integer32 (0..80)read-onlycurrent
psTemperatureTable
OBJECT-TYPE
Temperature Measurement Table.
1.3.6.1.4.1.885.3.2.2not-accessiblecurrent
psTemperatureEntry
OBJECT-TYPE
Temperature Measurement Table Entry.
1.3.6.1.4.1.885.3.2.2.1not-accessiblecurrent
psTemperatureIndex
OBJECT-TYPE
Temperature Probe Number
1.3.6.1.4.1.885.3.2.2.1.1Integer32 (1..8)read-onlycurrent
psTemperatureMeasurement
OBJECT-TYPE
Temperature Value In Centigrade.
1.3.6.1.4.1.885.3.2.2.1.2DisplayStringread-onlycurrent
psTemperatureAlarmStatus
OBJECT-TYPE
Temperature Probe Alarm Status
1.3.6.1.4.1.885.3.2.2.1.3INTEGER {high(0), low(1), noreply(2), none(3)}read-onlycurrent
psLVDTable
OBJECT-TYPE
Low Voltage Disconnect Table.
1.3.6.1.4.1.885.3.2.3not-accessiblecurrent
psLVDEntry
OBJECT-TYPE
Low Voltage Disconnect Table Entry.
1.3.6.1.4.1.885.3.2.3.1not-accessiblecurrent
psLVDIndex
OBJECT-TYPE
LVD Number
1.3.6.1.4.1.885.3.2.3.1.1Integer32read-onlycurrent
psLVDCircuitA
OBJECT-TYPE
LVD Circuit A Disconnect Voltage
1.3.6.1.4.1.885.3.2.3.1.2DisplayStringread-onlycurrent
psLVDCircuitB
OBJECT-TYPE
LVD Circuit B Disconnect Voltage
1.3.6.1.4.1.885.3.2.3.1.3DisplayStringread-onlycurrent
psLVDCircuitAAlarmStatus
OBJECT-TYPE
LVD Circuit A Alarm Status
1.3.6.1.4.1.885.3.2.3.1.4INTEGER {disconnected(0), noreply(1), boardfail(2), none(3)}read-onlycurrent
psLVDCircuitBAlarmStatus
OBJECT-TYPE
LVD Circuit B Alarm Status
1.3.6.1.4.1.885.3.2.3.1.5INTEGER {disconnected(0), noreply(1), boardfail(2), none(3)}read-onlycurrent
psDistributionTable
OBJECT-TYPE
Shunt Pod Table
1.3.6.1.4.1.885.3.2.4not-accessiblecurrent
psShuntEntry
OBJECT-TYPE
Shunt Pod Table Entry.
1.3.6.1.4.1.885.3.2.4.1not-accessiblecurrent
psShuntIndex
OBJECT-TYPE
Shunt Pod Number.
1.3.6.1.4.1.885.3.2.4.1.1Integer32 (1..16)read-onlycurrent
psShuntCurrent
OBJECT-TYPE
Shunt POD Current.
1.3.6.1.4.1.885.3.2.4.1.2DisplayStringread-onlycurrent
psShuntAlarmStatus
OBJECT-TYPE
Shunt POD Alarm Status. Values: 0 = Type, 1 = No Reply, 2 = No Alarm
1.3.6.1.4.1.885.3.2.4.1.3INTEGER {type(0), noreply(1), none(2)}read-onlycurrent
psShuntType
OBJECT-TYPE
Shunt POD Alarm Status. Values: 0 = System, 1 = Subsystem, 2 = Battery
1.3.6.1.4.1.885.3.2.4.1.4INTEGER {system(1), subsystem(2), battery(3)}read-onlycurrent
psPCUTable
OBJECT-TYPE
PCU Table.
1.3.6.1.4.1.885.3.2.5not-accessiblecurrent
psPCUEntry
OBJECT-TYPE
PCU Table Entry.
1.3.6.1.4.1.885.3.2.5.1not-accessiblecurrent
psPCUIndex
OBJECT-TYPE
PCU Number.
1.3.6.1.4.1.885.3.2.5.1.1Integer32 (1..80)read-onlycurrent
psPCUFail
OBJECT-TYPE
PCU Fail Alarm
1.3.6.1.4.1.885.3.2.5.1.2INTEGER {false(0), true(1)}read-onlycurrent
psPCUCurrent
OBJECT-TYPE
PCU Current
1.3.6.1.4.1.885.3.2.5.1.3Integer32read-onlycurrent
psPCUFerroGateway
OBJECT-TYPE
PCU is a Ferro Gateway Rectifier.
1.3.6.1.4.1.885.3.2.5.1.4INTEGER {false(0), true(1)}read-onlycurrent
psPCUProductNumber
OBJECT-TYPE
Rectifier Product Number.
1.3.6.1.4.1.885.3.2.5.1.5DisplayStringread-onlycurrent
psPCUSWVersion
OBJECT-TYPE
Rectifier Software Revision.
1.3.6.1.4.1.885.3.2.5.1.6DisplayStringread-onlycurrent
psPCUSerialNumber
OBJECT-TYPE
Rectifier Serial Number.
1.3.6.1.4.1.885.3.2.5.1.7DisplayStringread-onlycurrent
psPCUCapacity
OBJECT-TYPE
Rectifier Rated Current
1.3.6.1.4.1.885.3.2.5.1.8DisplayStringread-onlycurrent
psTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3
psAlarmsGeneral1
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.1
psAlarmsGeneral2
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.2
psAlarmsBattery
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.3
psPCUSummaryTypeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.4
psPCUSummaryTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.4.1
psPCUNodeTypeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.5
psPCUTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.5.1
psAlarmPCUId
OBJECT-TYPE
PCU Number.
1.3.6.1.4.1.885.3.3.5.1.1Integer32read-onlycurrent
psShuntTypeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.6
psShuntTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.6.1
psAlarmShuntId
OBJECT-TYPE
Shunt POD Number.
1.3.6.1.4.1.885.3.3.6.1.1Integer32read-onlycurrent
psLVDTypeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.7
psLVDTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.7.1
psAlarmLVDId
OBJECT-TYPE
The Analog LVD Number
1.3.6.1.4.1.885.3.3.7.1.1Integer32read-onlycurrent
psTemperatureTypeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.8
psTemperatureTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.8.1
psAlarmTemperatureId
OBJECT-TYPE
Temperature Probe Number.
1.3.6.1.4.1.885.3.3.8.1.1Integer32read-onlycurrent
psSysInfoTypeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.9
psSysInfoTraps
OBJECT-IDENTITY
1.3.6.1.4.1.885.3.3.9.1

Notifications

NameOIDStatus
psEmergencyStop
NOTIFICATION-TYPE
Emergency Stop Alarm.
1.3.6.1.4.1.885.3.3.1.1current
psAlarmVeryLowVoltage
NOTIFICATION-TYPE
50 Percent Battery On Discharge Alarm.
1.3.6.1.4.1.885.3.3.1.2current
psAlarmLowVoltage
NOTIFICATION-TYPE
Battery On Discharge Alarm.
1.3.6.1.4.1.885.3.3.1.3current
psAlarmSystemHighVoltage1
NOTIFICATION-TYPE
High Voltage 1 Alarm.
1.3.6.1.4.1.885.3.3.1.4current
psAlarmSystemHighVoltage2
NOTIFICATION-TYPE
High Voltage 2 Alarm.
1.3.6.1.4.1.885.3.3.1.5current
psAlarmSubsystemLowVoltage
NOTIFICATION-TYPE
Subsystem Low Voltage Alarm.
1.3.6.1.4.1.885.3.3.1.6current
psAlarmSubsystemHighVoltage
NOTIFICATION-TYPE
Subsystem High Voltage Alarm.
1.3.6.1.4.1.885.3.3.1.7current
psAlarmSystemFuse
NOTIFICATION-TYPE
System Fuse Alarm.
1.3.6.1.4.1.885.3.3.1.8current
psAlarmSubsystemFuse
NOTIFICATION-TYPE
Subsystem Fuse Alarm.
1.3.6.1.4.1.885.3.3.1.9current
psAlarmAllACOff
NOTIFICATION-TYPE
All AC Off Alarm.
1.3.6.1.4.1.885.3.3.1.10current
psAlarmSystemOverCurrent
NOTIFICATION-TYPE
System Over Current Alarm.
1.3.6.1.4.1.885.3.3.1.11current
psAlarmSubsystemOverCurrent
NOTIFICATION-TYPE
Subsystem Over Current Alarm.
1.3.6.1.4.1.885.3.3.1.12current
psAlarmLVDsAreInhibited
NOTIFICATION-TYPE
LVDs Are Inhibited Alarm.
1.3.6.1.4.1.885.3.3.1.13current
psAlarmTestEqualizeMode
NOTIFICATION-TYPE
Test/Equalize Mode Active.
1.3.6.1.4.1.885.3.3.1.14current
psAlarmMinor
NOTIFICATION-TYPE
System Minor Alarm.
1.3.6.1.4.1.885.3.3.1.15current
psAlarmMajor
NOTIFICATION-TYPE
System Major Alarm.
1.3.6.1.4.1.885.3.3.1.16current
psAlarmSenseVoltageFuse
NOTIFICATION-TYPE
Sense Voltage Fuse Alarm.
1.3.6.1.4.1.885.3.3.1.17current
psAlarmSystemVoltageFuse
NOTIFICATION-TYPE
System Voltage Fuse Alarm.
1.3.6.1.4.1.885.3.3.1.18current
psAlarmNoSystemVoltage
NOTIFICATION-TYPE
No System Voltage Alarm.
1.3.6.1.4.1.885.3.3.1.19current
psAlarmNoSubsystemVoltage
NOTIFICATION-TYPE
No Subsystem Voltage Alarm.
1.3.6.1.4.1.885.3.3.1.20current
psAlarmNoSenseVoltage
NOTIFICATION-TYPE
No Sense Voltage Alarm.
1.3.6.1.4.1.885.3.3.1.21current
psAlarmDisplayNoReply
NOTIFICATION-TYPE
Display Communications Alarm.
1.3.6.1.4.1.885.3.3.1.22current
psAlarmSubsystemMajor
NOTIFICATION-TYPE
Subsystem Major Alarm.
1.3.6.1.4.1.885.3.3.1.23current
psAlarmSubsystemMinor
NOTIFICATION-TYPE
Subsystem Minor Alarm.
1.3.6.1.4.1.885.3.3.1.24current
psAlarmHighACLine
NOTIFICATION-TYPE
High AC Line Alarm.
1.3.6.1.4.1.885.3.3.1.25current
psAlarmSenseVoltageError
NOTIFICATION-TYPE
Sense Voltage Error Alarm.
1.3.6.1.4.1.885.3.3.1.26current
psTestEqualizeHardwareInput
NOTIFICATION-TYPE
The MCA Test Equalize Hardware Input Active.
1.3.6.1.4.1.885.3.3.2.1current
psPCUFailMajor
NOTIFICATION-TYPE
PCU Fail Major Alarm.
1.3.6.1.4.1.885.3.3.2.2current
psPCUFailMinor
NOTIFICATION-TYPE
PCU Fail Minor Alarm.
1.3.6.1.4.1.885.3.3.2.3current
psLVDAlarmMajor
NOTIFICATION-TYPE
LVD Major Alarm.
1.3.6.1.4.1.885.3.3.2.4current
psLVDAlarmMinor
NOTIFICATION-TYPE
LVD Minor Alarm.
1.3.6.1.4.1.885.3.3.2.5current
psPCULoadShare
NOTIFICATION-TYPE
PCU Load Share Alarm.
1.3.6.1.4.1.885.3.3.2.6current
psACFailMajor
NOTIFICATION-TYPE
AC Fail Major Alarm.
1.3.6.1.4.1.885.3.3.2.7current
psACFailMinor
NOTIFICATION-TYPE
AC Fail Minor Alarm.
1.3.6.1.4.1.885.3.3.2.8current
psMCACommFail
NOTIFICATION-TYPE
MCA Communications Failure Alarm.
1.3.6.1.4.1.885.3.3.2.9current
psHVSActive
NOTIFICATION-TYPE
High Voltage Shutdown Active.
1.3.6.1.4.1.885.3.3.2.10current
psRemoteHVSActive
NOTIFICATION-TYPE
Remote High Voltage Shutdown Active.
1.3.6.1.4.1.885.3.3.2.11current
psRemoteEstopActive
NOTIFICATION-TYPE
Remote Emergency Stop Active.
1.3.6.1.4.1.885.3.3.2.12current
psAlarmBatteryChargeOverCurrent
NOTIFICATION-TYPE
Battery Charge Over Current Alarm.
1.3.6.1.4.1.885.3.3.3.1current
psBatteryCurrentLimitInhibited
NOTIFICATION-TYPE
Battery Current Limit Inhibited Alarm.
1.3.6.1.4.1.885.3.3.3.2current
psAlarmBatteryPoorHealth
NOTIFICATION-TYPE
Battery Poor Health Alarm.
1.3.6.1.4.1.885.3.3.3.3current
psAlarmBatteryReserveLow
NOTIFICATION-TYPE
Battery Reserve Low Alarm.
1.3.6.1.4.1.885.3.3.3.4current
psAlarmPCUSummary
NOTIFICATION-TYPE
PCU Alarm Active.
1.3.6.1.4.1.885.3.3.4.1.2current
psAlarmPCUHighACLine
NOTIFICATION-TYPE
PCU High AC Line Alarm.
1.3.6.1.4.1.885.3.3.5.1.2current
psAlarmPCUControllerFailure
NOTIFICATION-TYPE
PCU Controller Failure Alarm.
1.3.6.1.4.1.885.3.3.5.1.3current
psAlarmPCUFanSlowOrStopped
NOTIFICATION-TYPE
PCU Fan Slow Or Stopped Alarm.
1.3.6.1.4.1.885.3.3.5.1.4current
psAlarmPCUTurnedOffByMca
NOTIFICATION-TYPE
PCU Turned Off By MCA.
1.3.6.1.4.1.885.3.3.5.1.5current
psAlarmPCUCircuitBreakerOff
NOTIFICATION-TYPE
PCU Circuit Breaker Off Alarm.
1.3.6.1.4.1.885.3.3.5.1.6current
psAlarmPCUDCorACConvertFail
NOTIFICATION-TYPE
PCU Converter Fail Alarm.
1.3.6.1.4.1.885.3.3.5.1.7current
psAlarmPCUThermalAlarmorCurrentLimit
NOTIFICATION-TYPE
PCU Thermal Current Limit Alarm.
1.3.6.1.4.1.885.3.3.5.1.8current
psAlarmPCUEmergencyStop
NOTIFICATION-TYPE
PCU Emergency Stop Alarm.
1.3.6.1.4.1.885.3.3.5.1.9current
psAlarmPCUInputSwitchOff
NOTIFICATION-TYPE
PCU Input Switch Off Alarm.
1.3.6.1.4.1.885.3.3.5.1.10current
psAlarmPCUHighVoltageShutdown
NOTIFICATION-TYPE
PCU High Voltage Shutdown Alarm.
1.3.6.1.4.1.885.3.3.5.1.11current
psAlarmPCUACInputIsOffOrLow
NOTIFICATION-TYPE
PCU AC Input Is Off Or Low Alarm.
1.3.6.1.4.1.885.3.3.5.1.12current
psAlarmPCUCommunicationFailureWithMCA
NOTIFICATION-TYPE
PCU Communication Failure Alarm.
1.3.6.1.4.1.885.3.3.5.1.13current
psAlarmPCUSenseLeadOpen
NOTIFICATION-TYPE
PCU Sense Lead Open Alarm.
1.3.6.1.4.1.885.3.3.5.1.14current
psAlarmShuntType
NOTIFICATION-TYPE
Shunt POD Type Alarm.
1.3.6.1.4.1.885.3.3.6.1.2current
psAlarmShuntNoReply
NOTIFICATION-TYPE
Shunt POD Communications Alarm.
1.3.6.1.4.1.885.3.3.6.1.3current
psAlarmLVDDisconnectedA
NOTIFICATION-TYPE
LVD Circuit A Disconnected Alarm.
1.3.6.1.4.1.885.3.3.7.1.2current
psAlarmLVDNoReplyA
NOTIFICATION-TYPE
LVD Circuit A Communications Alarm.
1.3.6.1.4.1.885.3.3.7.1.3current
psAlarmLVDBoardFailA
NOTIFICATION-TYPE
LVD Board Circuit A Fail Alarm.
1.3.6.1.4.1.885.3.3.7.1.4current
psAlarmLVDDisconnectedB
NOTIFICATION-TYPE
LVD Circuit B Disconnected Alarm.
1.3.6.1.4.1.885.3.3.7.1.5current
psAlarmLVDNoReplyB
NOTIFICATION-TYPE
LVD Circuit B No Communications Alarm.
1.3.6.1.4.1.885.3.3.7.1.6current
psAlarmLVDBoardFailB
NOTIFICATION-TYPE
LVD Board Circuit B Fail Alarm.
1.3.6.1.4.1.885.3.3.7.1.7current
psAlarmTemperatureHigh
NOTIFICATION-TYPE
Temperature High Alarm.
1.3.6.1.4.1.885.3.3.8.1.2current
psAlarmTemperatureLow
NOTIFICATION-TYPE
Temperature Low Alarm.
1.3.6.1.4.1.885.3.3.8.1.3current
psAlarmTemperatureNoReply
NOTIFICATION-TYPE
Temperature Communications Alarm.
1.3.6.1.4.1.885.3.3.8.1.4current
psAlarmSysInfoError1
NOTIFICATION-TYPE
SysInfo Error 1.
1.3.6.1.4.1.885.3.3.9.1.1current
psAlarmSysInfoError2
NOTIFICATION-TYPE
SysInfo Error 2.
1.3.6.1.4.1.885.3.3.9.1.2current
psAlarmSysInfoString1
NOTIFICATION-TYPE
SysInfo String 1.
1.3.6.1.4.1.885.3.3.9.1.3current
psAlarmSysInfoString2
NOTIFICATION-TYPE
SysInfo String 2.
1.3.6.1.4.1.885.3.3.9.1.4current
psAlarmSysInfoString3
NOTIFICATION-TYPE
SysInfo String 3.
1.3.6.1.4.1.885.3.3.9.1.5current
psAlarmSysInfoString4
NOTIFICATION-TYPE
SysInfo String 4.
1.3.6.1.4.1.885.3.3.9.1.6current
psAlarmSysInfoString5
NOTIFICATION-TYPE
SysInfo String 5.
1.3.6.1.4.1.885.3.3.9.1.7current
psAlarmSysInfoString6
NOTIFICATION-TYPE
SysInfo String 6.
1.3.6.1.4.1.885.3.3.9.1.8current
psAlarmSysInfoString7
NOTIFICATION-TYPE
SysInfo String 7.
1.3.6.1.4.1.885.3.3.9.1.9current
psAlarmSysInfoString8
NOTIFICATION-TYPE
SysInfo String 8.
1.3.6.1.4.1.885.3.3.9.1.10current
psAlarmSysInfoString9
NOTIFICATION-TYPE
SysInfo String 9.
1.3.6.1.4.1.885.3.3.9.1.11current
psAlarmSysInfoString10
NOTIFICATION-TYPE
SysInfo String 10.
1.3.6.1.4.1.885.3.3.9.1.12current