UBQS-SYSTEM-MIB
- Registered at
- 1.3.6.1.4.1.7800.100.1
- Last updated
- 2009-06-17 00:00
- Organization
- Ubiquoss Corp.
- Revisions
- 2010-12-17 00:00
- Namespace
- ubiquoss
- Source file
UBQS-SYSTEM-MIB- Digest
sha256:8ca09b0bd437ecf8c2697d6438ee3e4f36ee7be96c8243496f288e89bb57708e
Description
The UBQS-SYSTEM-MIB is used to get the system information.
Contact
Ubiquoss Customer Service Postal: 24F Milennium B/D, 467-12, Dogok-Dong, GangNam-Gu, Seoul 135-270 Korea Tel: 82-2-2190-3100
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| UBQS-SMI | ubiMgmtv2 |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC UBQS-SMI UBQS-SYSTEM-MIB
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.7800.100.1.1 | ubiSystemMIBObjects | |
| 1.3.6.1.4.1.7800.100.1.2 | ubiSystemMIBNotificationPrefix |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ubiSystemMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1 | |||
| ubiSysReset OBJECT-TYPE Reset the system. | 1.3.6.1.4.1.7800.100.1.1.1 | INTEGER {reset(1)} | write-only | mandatory |
| ubiSysInfo OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.2 | |||
| ubiSysModel OBJECT-TYPE The object identifier for the manufacturer model. | 1.3.6.1.4.1.7800.100.1.1.2.1 | OBJECT IDENTIFIER | read-only | mandatory |
| ubiHwVersion OBJECT-TYPE Hardware version of the system. | 1.3.6.1.4.1.7800.100.1.1.2.2 | DisplayString | read-only | mandatory |
| ubiSwVersion OBJECT-TYPE Software version of the system. | 1.3.6.1.4.1.7800.100.1.1.2.3 | DisplayString | read-only | mandatory |
| ubiReleaseDate OBJECT-TYPE The date of release for system OS. | 1.3.6.1.4.1.7800.100.1.1.2.4 | DisplayString | read-only | mandatory |
| ubiSerialNumber OBJECT-TYPE Serial number of the system. | 1.3.6.1.4.1.7800.100.1.1.2.5 | DisplayString | read-only | mandatory |
| ubiSysPhysAddress OBJECT-TYPE System mac address | 1.3.6.1.4.1.7800.100.1.1.2.6 | PhysAddress | read-only | mandatory |
| ubiSysClock OBJECT-TYPE Current local time of the system. Clock SET: HH:MM:SS - Current Time <1-31> - Day of the month MONTH - Month of the year (First three letters of the month) <1993-2035> - Year SET Example 13:10:00 3 Jan 2010 | 1.3.6.1.4.1.7800.100.1.1.2.7 | DisplayString | read-write | mandatory |
| ubiSysTimeZone OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.2.8 | |||
| ubiSysTimeZoneName OBJECT-TYPE System timezone name. | 1.3.6.1.4.1.7800.100.1.1.2.8.1 | DisplayString | read-write | current |
| ubiSysTimeZoneOffset OBJECT-TYPE System timezone offset(Hours:Minutes). | 1.3.6.1.4.1.7800.100.1.1.2.8.2 | DisplayString | read-write | current |
| ubiSysBanner OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.2.9 | |||
| ubiSysBannerLogin OBJECT-TYPE null string -> no banner login 'default' -> banner login default STRING -> banner login WORD | 1.3.6.1.4.1.7800.100.1.1.2.9.1 | DisplayString | read-write | current |
| ubiSysBannerMotd OBJECT-TYPE null string -> no banner motd 'default' -> banner motd default STRING -> banner motd WORD | 1.3.6.1.4.1.7800.100.1.1.2.9.2 | DisplayString | read-write | current |
| ubiShelfPhysAddress OBJECT-TYPE System shelf mac address. | 1.3.6.1.4.1.7800.100.1.1.2.10 | PhysAddress | read-only | mandatory |
| ubiBspVersion OBJECT-TYPE System Bsp Versoin. | 1.3.6.1.4.1.7800.100.1.1.2.11 | DisplayString | read-only | mandatory |
| ubiSysResetReason OBJECT-TYPE System Reset Reason. | 1.3.6.1.4.1.7800.100.1.1.2.12 | DisplayString | accessible-for-notify | mandatory |
| ubiSysLedTest OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.6 | |||
| ubiLedTestTimeout OBJECT-TYPE The timeout to terminate the LED Test. If the timeout is zero, that is set to default. | 1.3.6.1.4.1.7800.100.1.1.6.1 | Integer32 (1..300) | read-write | current |
| ubiLedTestTrigger OBJECT-TYPE Trigger and stop the LED Test. | 1.3.6.1.4.1.7800.100.1.1.6.2 | INTEGER {none(0), testing(1), stop(2)} | read-write | current |
| ubiLedTestSlotId OBJECT-TYPE LED test Slot id | 1.3.6.1.4.1.7800.100.1.1.6.3 | Integer32 | read-write | current |
| ubiSysRedundancy OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.7 | |||
| ubiSysRedundancyInfoTable OBJECT-TYPE Table of redundancy information | 1.3.6.1.4.1.7800.100.1.1.7.1 | not-accessible | current | |
| ubiSysRedundancyInfoEntry OBJECT-TYPE Entry of redundancy information | 1.3.6.1.4.1.7800.100.1.1.7.1.1 | not-accessible | current | |
| ubiSCURedundancyRole OBJECT-TYPE SCU role | 1.3.6.1.4.1.7800.100.1.1.7.1.1.1 | INTEGER {active(1), standby(2)} | read-only | current |
| ubiSCUPosition OBJECT-TYPE SCU postion | 1.3.6.1.4.1.7800.100.1.1.7.1.1.2 | INTEGER {left(1), right(2)} | read-only | current |
| ubiSCUMngLinkStatus OBJECT-TYPE mng port status of SCU | 1.3.6.1.4.1.7800.100.1.1.7.1.1.3 | INTEGER {down(0), up(1)} | read-only | current |
| ubiSCUIpAddress OBJECT-TYPE IP address of SCU | 1.3.6.1.4.1.7800.100.1.1.7.1.1.4 | IpAddress | read-only | current |
| ubiSCUPeerEquipStatus OBJECT-TYPE Peer Equip status of SCU | 1.3.6.1.4.1.7800.100.1.1.7.1.1.5 | INTEGER {unequip(0), equip(1)} | read-only | current |
| ubiSysRedundancyReload OBJECT-TYPE Reload Active and/or Standby | 1.3.6.1.4.1.7800.100.1.1.7.2 | INTEGER {reload_peer(1), reload_shelf(2)} | write-only | current |
| ubiSysRedundancyPeerImage OBJECT-TYPE Peer boot image | 1.3.6.1.4.1.7800.100.1.1.7.3 | DisplayString | write-only | current |
| ubiSysBarCode OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.8 | |||
| ubiSysBarcodeSystem OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.1.8.1 | |||
| ubiSysBarcodeSystemString OBJECT-TYPE The textual barcode of system. | 1.3.6.1.4.1.7800.100.1.1.8.1.1 | DisplayString | read-only | current |
| ubiSysBarcodePowerTable OBJECT-TYPE This table contains information for power barcode. | 1.3.6.1.4.1.7800.100.1.1.8.2 | not-accessible | current | |
| ubiSysBarcodePowerEntry OBJECT-TYPE Barcode Information about the power. | 1.3.6.1.4.1.7800.100.1.1.8.2.1 | not-accessible | current | |
| ubiSysBarcodePowerIndex OBJECT-TYPE A unique value for each power entity | 1.3.6.1.4.1.7800.100.1.1.8.2.1.1 | INTEGER | read-only | current |
| ubiSysBarcodePowerString OBJECT-TYPE The textual barcode of power entity | 1.3.6.1.4.1.7800.100.1.1.8.2.1.2 | DisplayString | read-only | current |
| ubiSysBarcodeFanTable OBJECT-TYPE This table contains information for fan barcode. | 1.3.6.1.4.1.7800.100.1.1.8.3 | not-accessible | current | |
| ubiSysBarcodeFanEntry OBJECT-TYPE Barcode Information about the fan | 1.3.6.1.4.1.7800.100.1.1.8.3.1 | not-accessible | current | |
| ubiSysBarcodeFanIndex OBJECT-TYPE A unique value for each fan entity | 1.3.6.1.4.1.7800.100.1.1.8.3.1.1 | INTEGER | read-only | current |
| ubiSysBarcodeFanString OBJECT-TYPE The textual barcode of fan entity. | 1.3.6.1.4.1.7800.100.1.1.8.3.1.2 | DisplayString | read-only | current |
| ubiSysBarcodeUplinkTable OBJECT-TYPE This table contains information for uplink module's barcode. | 1.3.6.1.4.1.7800.100.1.1.8.4 | not-accessible | current | |
| ubiSysBarcodeUplinkEntry OBJECT-TYPE Barcode Information about the uplink module. | 1.3.6.1.4.1.7800.100.1.1.8.4.1 | not-accessible | current | |
| ubiSysBarcodeUplinkIndex OBJECT-TYPE A unique value for each uplink module. | 1.3.6.1.4.1.7800.100.1.1.8.4.1.1 | INTEGER | read-only | current |
| ubiSysBarcodeUplinkString OBJECT-TYPE The textual barcode of uplink module. | 1.3.6.1.4.1.7800.100.1.1.8.4.1.2 | DisplayString | read-only | current |
| ubiSysBarcodeSlotTable OBJECT-TYPE This table contains information for slot's barcode. | 1.3.6.1.4.1.7800.100.1.1.8.5 | not-accessible | current | |
| ubiSysBarcodeSlotEntry OBJECT-TYPE Barcode Information about the slot. | 1.3.6.1.4.1.7800.100.1.1.8.5.1 | not-accessible | current | |
| ubiSysBarcodeSlotIndex OBJECT-TYPE A unique value for each slot. | 1.3.6.1.4.1.7800.100.1.1.8.5.1.1 | INTEGER | read-only | current |
| ubiSysBarcodeSlotString OBJECT-TYPE The textual barcode of slot. | 1.3.6.1.4.1.7800.100.1.1.8.5.1.2 | DisplayString | read-only | current |
| ubiSysBarcodeScuTable OBJECT-TYPE This table contains information for SCU's barcode. | 1.3.6.1.4.1.7800.100.1.1.8.6 | not-accessible | current | |
| ubiSysBarcodeScuEntry OBJECT-TYPE Barcode Information about the SCU. | 1.3.6.1.4.1.7800.100.1.1.8.6.1 | not-accessible | current | |
| ubiSysBarcodeScuIndex OBJECT-TYPE A unique value for each SCU. | 1.3.6.1.4.1.7800.100.1.1.8.6.1.1 | INTEGER | read-only | current |
| ubiSysBarcodeScuString OBJECT-TYPE The textual barcode of SCU. | 1.3.6.1.4.1.7800.100.1.1.8.6.1.2 | DisplayString | read-only | current |
| ubiSystemMIBNotificationPrefix OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.2 | |||
| ubiSystemMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.3 | |||
| ubiSysMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.3.1 | |||
| ubiSysMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7800.100.1.3.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| ubiSysMIBCompliance MODULE-COMPLIANCE The compliance statement for entities which implement the Ubiquoss system MIB. | 1.3.6.1.4.1.7800.100.1.3.1.1 | current |
| ubiSysInfoMIBGroup OBJECT-GROUP The collection of objects which are used to get the system information | 1.3.6.1.4.1.7800.100.1.3.2.1 | current |
| ubiSysRscMIBGroup OBJECT-GROUP The collection of objects which are used to manager the system resource | 1.3.6.1.4.1.7800.100.1.3.2.2 | current |
| ubiSysMiscGroup OBJECT-GROUP The collection of objects which are used to manager the miscellaneous information of system. | 1.3.6.1.4.1.7800.100.1.3.2.3 | current |