MIBs Depot

UBQS-AFSMGR-MIB

Registered at
1.3.6.1.4.1.7800.100.7
Last updated
2010-04-12 00:00
Organization
Ubiquoss Corp.
Namespace
ubiquoss
Source file
UBQS-AFSMGR-MIB
Digest
sha256:1d2a15df575b97d10d4ea6f3b062c495b6caf3b8661b8b8a46591e66204987f2

Description

AFSMGR Event Group

Contact

Ubiquoss Customer Service Postal: 24F Milennium B/D, 467-12, Dogok-Dong, GangNam-Gu, Seoul 135-270 Korea Tel: 82-2-2190-3100

Imports

FromSymbols
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-MIBsysContact, sysLocation, sysName, sysObjectID
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION
UBQS-SMIubiMgmtv2

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UBQS-AFSMGR-MIB
UBQS-SMI

Objects

NameOIDSyntaxAccessStatus
currentAlarmTable
OBJECT-TYPE
Description.
1.3.6.1.4.1.7800.100.7.1not-accessiblecurrent
currentAlarmEntry
OBJECT-TYPE
Description.
1.3.6.1.4.1.7800.100.7.1.1not-accessiblecurrent
alarmIndex
OBJECT-TYPE
current Alarm index.
1.3.6.1.4.1.7800.100.7.1.1.1Integer32read-onlycurrent
alarmId
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.2DisplayStringread-onlycurrent
alarmType
OBJECT-TYPE
Description 1 : equipment 2 : communications 3 : QoS 4 : processing 5 : environment
1.3.6.1.4.1.7800.100.7.1.1.3INTEGER {equipment(1), communications(2), qos(3), processing(4), environment(5)}read-onlycurrent
alarmSeverity
OBJECT-TYPE
Description 1 : critical 2 : major 3 : minor 4 : warning 5 : indeterminate
1.3.6.1.4.1.7800.100.7.1.1.4INTEGER {critical(1), major(2), minor(3), warning(4), indeterminate(5)}read-onlycurrent
alarmPhysicalLoc
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.5DisplayStringread-onlycurrent
alarmLogicalLoc
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.6DisplayStringread-onlycurrent
alarmCurStatus
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.7Integer32read-onlycurrent
alarmAuxinfo
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.8DisplayStringread-onlycurrent
alarmDateTime
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.9DisplayStringread-onlycurrent
alarmStatus
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.1.1.10Integer32read-onlycurrent
eventLogTable
OBJECT-TYPE
Description.
1.3.6.1.4.1.7800.100.7.2not-accessiblecurrent
eventLogEntry
OBJECT-TYPE
Description.
1.3.6.1.4.1.7800.100.7.2.1not-accessiblecurrent
eventIndex
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.2.1.1Integer32read-onlycurrent
eventId
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.2.1.2DisplayStringread-onlycurrent
eventType
OBJECT-TYPE
Description 1 : equipment 2 : communications 3 : QoS 4 : processing 5 : environment
1.3.6.1.4.1.7800.100.7.2.1.3INTEGER {equipment(1), communications(2), qos(3), processing(4), environment(5)}read-onlycurrent
eventSeverity
OBJECT-TYPE
Description 1 : critical 2 : major 3 : minor 4 : warning 5 : indeterminate
1.3.6.1.4.1.7800.100.7.2.1.4INTEGER {critical(1), major(2), minor(3), warning(4), indeterminate(5)}read-onlycurrent
eventValue
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.2.1.5DisplayStringread-onlycurrent
eventDateTime
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.2.1.6DisplayStringread-onlycurrent
eventStatus
OBJECT-TYPE
Description
1.3.6.1.4.1.7800.100.7.2.1.7Integer32read-onlycurrent
afsmgrEventManagerTrap
OBJECT-IDENTITY
1.3.6.1.4.1.7800.100.7.3

Notifications

NameOIDStatus
sysWarmStartNoti
NOTIFICATION-TYPE
System Warm-Start Notification.
1.3.6.1.4.1.7800.100.7.3.1current
sysColdStartNoti
NOTIFICATION-TYPE
System Cold-Start Notification.
1.3.6.1.4.1.7800.100.7.3.2current
linkUpNoti
NOTIFICATION-TYPE
Link Up Notification.
1.3.6.1.4.1.7800.100.7.3.3current
linkDownNoti
NOTIFICATION-TYPE
Link Down Notification.
1.3.6.1.4.1.7800.100.7.3.4current
cpuOverloadFallingNoti
NOTIFICATION-TYPE
CPU Overload Falling Notification.
1.3.6.1.4.1.7800.100.7.3.5current
cpuOverloadRisingNoti
NOTIFICATION-TYPE
CPU Overload Rising Notification.
1.3.6.1.4.1.7800.100.7.3.6current
gbicOperNoti
NOTIFICATION-TYPE
Gbic Equip/Unequip Operation Notification.
1.3.6.1.4.1.7800.100.7.3.7current
memoryOverloadNoti
NOTIFICATION-TYPE
Memory Overload Notification.
1.3.6.1.4.1.7800.100.7.3.8current
slotOperNoti
NOTIFICATION-TYPE
Slot Equip/Unequip Operation Notification.
1.3.6.1.4.1.7800.100.7.3.9current
tempLowNoti
NOTIFICATION-TYPE
Temperature Low Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.10current
tempHighNoti
NOTIFICATION-TYPE
Temperature High Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.11current
fanAlarmNoti
NOTIFICATION-TYPE
Fan Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.12current
fmuEquipStatusNoti
NOTIFICATION-TYPE
Fan Module Unit Equip/Unequip Status Notification.
1.3.6.1.4.1.7800.100.7.3.13current
psuAlarmNoti
NOTIFICATION-TYPE
Power Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.14current
psuEquipStatusNoti
NOTIFICATION-TYPE
Power Supply Unit Equip/Unequip Status Notification.
1.3.6.1.4.1.7800.100.7.3.15current
portAdminNoti
NOTIFICATION-TYPE
Port Administration Status Notification.
1.3.6.1.4.1.7800.100.7.3.16current
fanOperStatusNoti
NOTIFICATION-TYPE
Fan Operational Status Notification.
1.3.6.1.4.1.7800.100.7.3.17current
rmonRisingNoti
NOTIFICATION-TYPE
Rmon Rising Notification.
1.3.6.1.4.1.7800.100.7.3.18current
rmonFallingNoti
NOTIFICATION-TYPE
Rmon Falling Notification.
1.3.6.1.4.1.7800.100.7.3.19current
portSLDNoti
NOTIFICATION-TYPE
Port Self-Loop Detection Notification.
1.3.6.1.4.1.7800.100.7.3.20current
remoteConnection
NOTIFICATION-TYPE
Remote connection Notification.
1.3.6.1.4.1.7800.100.7.3.30current
ponDriftWindowNoti
NOTIFICATION-TYPE
Onu Drift Window Notification.
1.3.6.1.4.1.7800.100.7.3.41current
ponGemChannelLossNoti
NOTIFICATION-TYPE
Loss of GEM channel delineation Notification.
1.3.6.1.4.1.7800.100.7.3.42current
ponAckLossNoti
NOTIFICATION-TYPE
Loss of acknowledge with ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.43current
ponSigDegradeNoti
NOTIFICATION-TYPE
Signal Degraded of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.44current
ponSigFailNoti
NOTIFICATION-TYPE
Signal Fail of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.45current
ponPhysEquipErrNoti
NOTIFICATION-TYPE
Physical Equipment Error of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.46current
ponKeySyncLossNoti
NOTIFICATION-TYPE
Loss of Key sync with ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.47current
ponTransIfWarmNoti
NOTIFICATION-TYPE
Transmission Interference Warning Notification.
1.3.6.1.4.1.7800.100.7.3.48current
ponTransIfAlarmNoti
NOTIFICATION-TYPE
Transmission Interference Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.49current
ponRemoDefectIndNoti
NOTIFICATION-TYPE
Remote Defect Indication of ONUi Notification.
1.3.6.1.4.1.7800.100.7.3.50current
onuOperStatusNoti
NOTIFICATION-TYPE
Onu Operation Status Notification.
1.3.6.1.4.1.7800.100.7.3.51current
oltAlarmNoti
NOTIFICATION-TYPE
Olt Alarm Notification.
1.3.6.1.4.1.7800.100.7.3.52current
oltLinkFaultNoti
NOTIFICATION-TYPE
Olt Link Fault Notification.
1.3.6.1.4.1.7800.100.7.3.53current
ontDyingGaspNoti
NOTIFICATION-TYPE
Ont Dying Gasp Notification.
1.3.6.1.4.1.7800.100.7.3.54current
ponLinkStatusNoti
NOTIFICATION-TYPE
Pon Link Status Notification.
1.3.6.1.4.1.7800.100.7.3.55current
linkLoopbackTestNoti
NOTIFICATION-TYPE
Link Loopback Test Notification.
1.3.6.1.4.1.7800.100.7.3.57current
ponOltOperStatusNoti
NOTIFICATION-TYPE
Pon Olt Oper Status Notification.
1.3.6.1.4.1.7800.100.7.3.68current
ponOltAdminStatusNoti
NOTIFICATION-TYPE
Pon Olt Administrator Status Notification.
1.3.6.1.4.1.7800.100.7.3.69current
ponOnuAdminStatusNoti
NOTIFICATION-TYPE
Onu Admin Status Notification.
1.3.6.1.4.1.7800.100.7.3.70current
ponOnuRegisterSubMacNoti
NOTIFICATION-TYPE
Onu Subscriber Mac Registration Notification.
1.3.6.1.4.1.7800.100.7.3.71current
linkLoopbackTestFailNoti
NOTIFICATION-TYPE
Link Loopback Test Fail Notification.
1.3.6.1.4.1.7800.100.7.3.73current
ponOnuRegOverloadNoti
NOTIFICATION-TYPE
Pon Onu Register Overload Notification. (onu too many registration)
1.3.6.1.4.1.7800.100.7.3.93current
ponLinkRegNoti
NOTIFICATION-TYPE
Pon Link Register Notification.
1.3.6.1.4.1.7800.100.7.3.96current
ponOnuLoopDetectNoti
NOTIFICATION-TYPE
Onu Loop Detect Notification.
1.3.6.1.4.1.7800.100.7.3.97current
ponOltImageUpgrageNoti
NOTIFICATION-TYPE
Olt Image Upgrade Notification.
1.3.6.1.4.1.7800.100.7.3.98current
ponOltImageUpgrageFailNoti
NOTIFICATION-TYPE
Olt Image Upgrade Fail Notification.
1.3.6.1.4.1.7800.100.7.3.99current
onuImageUpgradeNoti
NOTIFICATION-TYPE
ONU Image Upgrade Notification.
1.3.6.1.4.1.7800.100.7.3.100current
onuImageUpgradeFailNoti
NOTIFICATION-TYPE
ONU Image Upgrade Fail Notification.
1.3.6.1.4.1.7800.100.7.3.101current
onuLdShutdownNoti
NOTIFICATION-TYPE
ONU LD shutdown Notification.
1.3.6.1.4.1.7800.100.7.3.102current
ponUnadminMacRegNoti
NOTIFICATION-TYPE
Unadmin Mac-address Register Notification.
1.3.6.1.4.1.7800.100.7.3.103current
ponDupMacRegNoti
NOTIFICATION-TYPE
Duplicated Mac-address Register Notification.
1.3.6.1.4.1.7800.100.7.3.104current
ponOnuTypeMismatchNoti
NOTIFICATION-TYPE
Onu Type Mismatch Notification.
1.3.6.1.4.1.7800.100.7.3.105current
ponOltDyingGaspNoti
NOTIFICATION-TYPE
Pon Olt DyingGasp Notification.
1.3.6.1.4.1.7800.100.7.3.106current
ponOltCableDownNoti
NOTIFICATION-TYPE
Olt Cable Down Notification.
1.3.6.1.4.1.7800.100.7.3.107current
ponPMCcrc32MonitorNoti
NOTIFICATION-TYPE
PMC CRC32 Monitor Notification.
1.3.6.1.4.1.7800.100.7.3.108current
imageUpDownloadStatusNoti
NOTIFICATION-TYPE
Image Up/Download Status Notification.
1.3.6.1.4.1.7800.100.7.3.109current
imageUpDownloadFailNoti
NOTIFICATION-TYPE
Image Up/Download Fail Notification.
1.3.6.1.4.1.7800.100.7.3.110current
configUpDownloadStatusNoti
NOTIFICATION-TYPE
Config Up/Download Status Notification.
1.3.6.1.4.1.7800.100.7.3.111current
sysRebootMaxTempNoti
NOTIFICATION-TYPE
System Reboot by Max Temperature Notification.
1.3.6.1.4.1.7800.100.7.3.112current
ponRogueOnuLdShutdown
NOTIFICATION-TYPE
Rogue Onu Ld Shutdown Notification.
1.3.6.1.4.1.7800.100.7.3.113current
scuOperStatusNoti
NOTIFICATION-TYPE
SCU Operation Status Notification.
1.3.6.1.4.1.7800.100.7.3.114current
configUpDownloadFailNoti
NOTIFICATION-TYPE
Config Up/Download Fail Notification.
1.3.6.1.4.1.7800.100.7.3.115current
ponOntRxPowerStatusNoti
NOTIFICATION-TYPE
Pon Ont Rx-optical-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.116current
ponOltRxPowerStatusNoti
NOTIFICATION-TYPE
Pon Olt Rx-optical-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.117current
ponOntTxPowerStatusNoti
NOTIFICATION-TYPE
Pon Ont Tx-optical-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.118current
ponOntTemperatureStatusNoti
NOTIFICATION-TYPE
Pon Ont Temperature-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.119current
ponOntVoltageStatusNoti
NOTIFICATION-TYPE
Pon Ont Voltage-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.120current
ponOntBiasStatusNoti
NOTIFICATION-TYPE
Pon Ont Bias-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.121current
ponOltRedSlaveFaultNoti
NOTIFICATION-TYPE
Pon Olt Redundancy Slave Link Fault Notification.
1.3.6.1.4.1.7800.100.7.3.122current
ponOltRedSwitchoverNoti
NOTIFICATION-TYPE
Pon Olt Redundancy Switchover Notification.
1.3.6.1.4.1.7800.100.7.3.123current
ponOnuOpticRxPowerOnusNoti
NOTIFICATION-TYPE
Pon Onus Low Optic Rx Power Notification.
1.3.6.1.4.1.7800.100.7.3.124current
ponOnuDownThresholdNoti
NOTIFICATION-TYPE
Pon Onu Down Threshold Notification.
1.3.6.1.4.1.7800.100.7.3.127current
ponOnuFanStatusNoti
NOTIFICATION-TYPE
Pon Onu Fan Status Notification.
1.3.6.1.4.1.7800.100.7.3.128current
ExternalACAlarm
NOTIFICATION-TYPE
External AC alarm
1.3.6.1.4.1.7800.100.7.3.129current
ExternalUnitAlarm
NOTIFICATION-TYPE
External unit alarm.
1.3.6.1.4.1.7800.100.7.3.130current
ponLoopCntThresholdNoti
NOTIFICATION-TYPE
Loop-Count-Threshold-alarm Notification.
1.3.6.1.4.1.7800.100.7.3.131current
scuUnequipNoti
NOTIFICATION-TYPE
scu unequip alarm
1.3.6.1.4.1.7800.100.7.3.132current
liuUnequipNoti
NOTIFICATION-TYPE
liu unequip alarm
1.3.6.1.4.1.7800.100.7.3.133current
fmuUnequipNoti
NOTIFICATION-TYPE
fmu unequip alarm
1.3.6.1.4.1.7800.100.7.3.134current
ponOltLineCodeErrorMonitorNoti
NOTIFICATION-TYPE
OLT line code errors monitor Notification
1.3.6.1.4.1.7800.100.7.3.135current
ponOltAlignmentErrorMonitorNoti
NOTIFICATION-TYPE
OLT alignment errors monitor Notification
1.3.6.1.4.1.7800.100.7.3.136current
scuEjectorAlarmNoti
NOTIFICATION-TYPE
SCU ejector alarm Notification
1.3.6.1.4.1.7800.100.7.3.137current
systemCheckAlarm
NOTIFICATION-TYPE
EMS System Check Monitor Notification
1.3.6.1.4.1.7800.100.7.3.138current
ponOnuRegThreshOverNoti
NOTIFICATION-TYPE
Pon Onu Registration Threshold Over Notification
1.3.6.1.4.1.7800.100.7.3.139current
dcTempHighNoti
NOTIFICATION-TYPE
Dc Board Temperature High Threshold Notification
1.3.6.1.4.1.7800.100.7.3.140current
dcTempLowNoti
NOTIFICATION-TYPE
Dc Board Temperature Low Threshold Notification
1.3.6.1.4.1.7800.100.7.3.141current
humidityHighNoti
NOTIFICATION-TYPE
Mainboard Humidity High Threshold Notification
1.3.6.1.4.1.7800.100.7.3.142current
humidityLowNoti
NOTIFICATION-TYPE
Mainboard Humidity Low Threshold Notification
1.3.6.1.4.1.7800.100.7.3.143current
dcHumidityHighNoti
NOTIFICATION-TYPE
Dc Board Humidity High Threshold Notification
1.3.6.1.4.1.7800.100.7.3.144current
dcHumidityLowNoti
NOTIFICATION-TYPE
Dc Board Humidity Low Threshold Notification
1.3.6.1.4.1.7800.100.7.3.145current
sysRebootMaxDcTempNoti
NOTIFICATION-TYPE
System Reboot by Max Dc Board Temperature Notification.
1.3.6.1.4.1.7800.100.7.3.146current
sysRebootMaxHumidNoti
NOTIFICATION-TYPE
System Reboot by Max Humidity Notification.
1.3.6.1.4.1.7800.100.7.3.147current
sysRebootMaxDcHumidNoti
NOTIFICATION-TYPE
System Reboot by Max Dc Board Humidity Notification.
1.3.6.1.4.1.7800.100.7.3.148current
fanSpeedHighNoti
NOTIFICATION-TYPE
Fan Speed High Notification.
1.3.6.1.4.1.7800.100.7.3.149current
psuUnequipNoti
NOTIFICATION-TYPE
Psu Unequip Notification.
1.3.6.1.4.1.7800.100.7.3.150current
doorOpenAlarmNoti
NOTIFICATION-TYPE
Door Open Monitor Notification
1.3.6.1.4.1.7800.100.7.3.151current
ExternalMajorAlarm
NOTIFICATION-TYPE
External Power Major Alarm.
1.3.6.1.4.1.7800.100.7.3.152current
Piu10gFanFailAlarm
NOTIFICATION-TYPE
10G PIU Fan Fail Alarm.
1.3.6.1.4.1.7800.100.7.3.157current