MIBs Depot

TUNNEL-MIB

Registered at
1.3.6.1.2.1.10.131
Last updated
2005-05-16 00:00
Organization
IETF IP Version 6 (IPv6) Working Group
Revisions
2005-05-16 00:00, 1999-08-24 12:00
Namespace
standard
Source file
TUNNEL-MIB
Digest
sha256:6439f7ef1e031022c7434ab35552fa6331c3a90a291037d5eb282d6f42b93173

Description

The MIB module for management of IP Tunnels, independent of the specific encapsulation scheme in use. Copyright (C) The Internet Society (2005). This version of this MIB module is part of RFC 4087; see the RFC itself for full legal notices.

Contact

Dave Thaler Microsoft Corporation One Microsoft Way Redmond, WA 98052-6399 EMail: dthaler@microsoft.com

Imports

FromSymbols
IANAifType-MIBIANAtunnelType
IF-MIBInterfaceIndexOrZero, ifIndex
INET-ADDRESS-MIBInetAddress, InetAddressType
IPV6-FLOW-LABEL-MIBIPv6FlowLabelOrAny
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission
SNMPv2-TCDisplayString, RowStatus, StorageType, TEXTUAL-CONVENTION

Imported by

7 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
IPV6-FLOW-LABEL-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TUNNEL-MIB

Objects

NameOIDSyntaxAccessStatus
tunnelMIBObjects
OBJECT-IDENTITY
1.3.6.1.2.1.10.131.1
tunnel
OBJECT-IDENTITY
1.3.6.1.2.1.10.131.1.1
tunnelIfTable
OBJECT-TYPE
The (conceptual) table containing information on configured tunnels.
1.3.6.1.2.1.10.131.1.1.1not-accessiblecurrent
tunnelIfEntry
OBJECT-TYPE
An entry (conceptual row) containing the information on a particular configured tunnel.
1.3.6.1.2.1.10.131.1.1.1.1not-accessiblecurrent
tunnelIfLocalAddress
OBJECT-TYPE
The address of the local endpoint of the tunnel (i.e., the source address used in the outer IP header), or 0.0.0.0 if unknown or if the tunnel is over IPv6. Since this object does not support IPv6, it is deprecated in favor of tunnelIfLocalInetAddress.
1.3.6.1.2.1.10.131.1.1.1.1.1IpAddressread-onlydeprecated
tunnelIfRemoteAddress
OBJECT-TYPE
The address of the remote endpoint of the tunnel (i.e., the destination address used in the outer IP header), or 0.0.0.0 if unknown, or an IPv6 address, or the tunnel is not a point-to-point link (e.g., if it is a 6to4 tunnel). Since this object does not support IPv6, it is deprecated in favor of tunnelIfRemoteInetAddress.
1.3.6.1.2.1.10.131.1.1.1.1.2IpAddressread-onlydeprecated
tunnelIfEncapsMethod
OBJECT-TYPE
The encapsulation method used by the tunnel.
1.3.6.1.2.1.10.131.1.1.1.1.3IANAtunnelTyperead-onlycurrent
tunnelIfHopLimit
OBJECT-TYPE
The IPv4 TTL or IPv6 Hop Limit to use in the outer IP header. A value of 0 indicates that the value is copied from the payload's header.
1.3.6.1.2.1.10.131.1.1.1.1.4Integer32 (0 | 1..255)read-writecurrent
tunnelIfSecurity
OBJECT-TYPE
The method used by the tunnel to secure the outer IP header. The value ipsec indicates that IPsec is used between the tunnel endpoints for authentication or encryption or both. More specific security-related information may be available in a MIB module for the security protocol in use.
1.3.6.1.2.1.10.131.1.1.1.1.5INTEGER {none(1), ipsec(2), other(3)}read-onlycurrent
tunnelIfTOS
OBJECT-TYPE
The method used to set the high 6 bits (the differentiated services codepoint) of the IPv4 TOS or IPv6 Traffic Class in the outer IP header. A value of -1 indicates that the bits are copied from the payload's header. A value of -2 indicates that a traffic conditioner is invoked and more information may be available in a traffic conditioner MIB module. A value between 0 and 63 inclusive indicates that the bit field is set to the indicated value. Note: instead of the name tunnelIfTOS, a better name would have been tunnelIfDSCPMethod, but the existing name appeared in RFC 2667 and existing objects cannot be renamed.
1.3.6.1.2.1.10.131.1.1.1.1.6Integer32 (-2..63)read-writecurrent
tunnelIfFlowLabel
OBJECT-TYPE
The method used to set the IPv6 Flow Label value. This object need not be present in rows where tunnelIfAddressType indicates the tunnel is not over IPv6. A value of -1 indicates that a traffic conditioner is invoked and more information may be available in a traffic conditioner MIB. Any other value indicates that the Flow Label field is set to the indicated value.
1.3.6.1.2.1.10.131.1.1.1.1.7IPv6FlowLabelOrAnyread-writecurrent
tunnelIfAddressType
OBJECT-TYPE
The type of address in the corresponding tunnelIfLocalInetAddress and tunnelIfRemoteInetAddress objects.
1.3.6.1.2.1.10.131.1.1.1.1.8InetAddressTyperead-writecurrent
tunnelIfLocalInetAddress
OBJECT-TYPE
The address of the local endpoint of the tunnel (i.e., the source address used in the outer IP header). If the address is unknown, the value is 0.0.0.0 for IPv4 or :: for IPv6. The type of this object is given by tunnelIfAddressType.
1.3.6.1.2.1.10.131.1.1.1.1.9InetAddressread-writecurrent
tunnelIfRemoteInetAddress
OBJECT-TYPE
The address of the remote endpoint of the tunnel (i.e., the destination address used in the outer IP header). If the address is unknown or the tunnel is not a point-to-point link (e.g., if it is a 6to4 tunnel), the value is 0.0.0.0 for tunnels over IPv4 or :: for tunnels over IPv6. The type of this object is given by tunnelIfAddressType.
1.3.6.1.2.1.10.131.1.1.1.1.10InetAddressread-writecurrent
tunnelIfEncapsLimit
OBJECT-TYPE
The maximum number of additional encapsulations permitted for packets undergoing encapsulation at this node. A value of -1 indicates that no limit is present (except as a result of the packet size).
1.3.6.1.2.1.10.131.1.1.1.1.11Integer32 (-1 | 0..255)read-writecurrent
tunnelConfigTable
OBJECT-TYPE
The (conceptual) table containing information on configured tunnels. This table can be used to map a set of tunnel endpoints to the associated ifIndex value. It can also be used for row creation. Note that every row in the tunnelIfTable with a fixed IPv4 destination address should have a corresponding row in the tunnelConfigTable, regardless of whether it was created via SNMP. Since this table does not support IPv6, it is deprecated in favor of tunnelInetConfigTable.
1.3.6.1.2.1.10.131.1.1.2not-accessibledeprecated
tunnelConfigEntry
OBJECT-TYPE
An entry (conceptual row) containing the information on a particular configured tunnel. Since this entry does not support IPv6, it is deprecated in favor of tunnelInetConfigEntry.
1.3.6.1.2.1.10.131.1.1.2.1not-accessibledeprecated
tunnelConfigLocalAddress
OBJECT-TYPE
The address of the local endpoint of the tunnel, or 0.0.0.0 if the device is free to choose any of its addresses at tunnel establishment time. Since this object does not support IPv6, it is deprecated in favor of tunnelInetConfigLocalAddress.
1.3.6.1.2.1.10.131.1.1.2.1.1IpAddressnot-accessibledeprecated
tunnelConfigRemoteAddress
OBJECT-TYPE
The address of the remote endpoint of the tunnel. Since this object does not support IPv6, it is deprecated in favor of tunnelInetConfigRemoteAddress.
1.3.6.1.2.1.10.131.1.1.2.1.2IpAddressnot-accessibledeprecated
tunnelConfigEncapsMethod
OBJECT-TYPE
The encapsulation method used by the tunnel. Since this object does not support IPv6, it is deprecated in favor of tunnelInetConfigEncapsMethod.
1.3.6.1.2.1.10.131.1.1.2.1.3IANAtunnelTypenot-accessibledeprecated
tunnelConfigID
OBJECT-TYPE
An identifier used to distinguish between multiple tunnels of the same encapsulation method, with the same endpoints. If the encapsulation protocol only allows one tunnel per set of endpoint addresses (such as for GRE or IP-in-IP), the value of this object is 1. For encapsulation methods (such as L2F) which allow multiple parallel tunnels, the manager is responsible for choosing any ID which does not conflict with an existing row, such as choosing a random number. Since this object does not support IPv6, it is deprecated in favor of tunnelInetConfigID.
1.3.6.1.2.1.10.131.1.1.2.1.4Integer32 (1..2147483647)not-accessibledeprecated
tunnelConfigIfIndex
OBJECT-TYPE
If the value of tunnelConfigStatus for this row is active, then this object contains the value of ifIndex corresponding to the tunnel interface. A value of 0 is not legal in the active state, and means that the interface index has not yet been assigned. Since this object does not support IPv6, it is deprecated in favor of tunnelInetConfigIfIndex.
1.3.6.1.2.1.10.131.1.1.2.1.5InterfaceIndexOrZeroread-onlydeprecated
tunnelConfigStatus
OBJECT-TYPE
The status of this row, by which new entries may be created, or old entries deleted from this table. The agent need not support setting this object to createAndWait or notInService since there are no other writable objects in this table, and writable objects in rows of corresponding tables such as the tunnelIfTable may be modified while this row is active. To create a row in this table for an encapsulation method which does not support multiple parallel tunnels with the same endpoints, the management station should simply use a tunnelConfigID of 1, and set tunnelConfigStatus to createAndGo. For encapsulation methods such as L2F which allow multiple parallel tunnels, the management station may select a pseudo-random number to use as the tunnelConfigID and set tunnelConfigStatus to createAndGo. In the event that this ID is already in use and an inconsistentValue is returned in response to the set operation, the management station should simply select a new pseudo-random number and retry the operation. Creating a row in this table will cause an interface index to be assigned by the agent in an implementation-dependent manner, and corresponding rows will be instantiated in the ifTable and the tunnelIfTable. The status of this row will become active as soon as the agent assigns the interface index, regardless of whether the interface is operationally up. Deleting a row in this table will likewise delete the corresponding row in the ifTable and in the tunnelIfTable. Since this object does not support IPv6, it is deprecated in favor of tunnelInetConfigStatus.
1.3.6.1.2.1.10.131.1.1.2.1.6RowStatusread-createdeprecated
tunnelInetConfigTable
OBJECT-TYPE
The (conceptual) table containing information on configured tunnels. This table can be used to map a set of tunnel endpoints to the associated ifIndex value. It can also be used for row creation. Note that every row in the tunnelIfTable with a fixed destination address should have a corresponding row in the tunnelInetConfigTable, regardless of whether it was created via SNMP.
1.3.6.1.2.1.10.131.1.1.3not-accessiblecurrent
tunnelInetConfigEntry
OBJECT-TYPE
An entry (conceptual row) containing the information on a particular configured tunnel. Note that there is a 128 subid maximum for object OIDs. Implementers need to be aware that if the total number of octets in tunnelInetConfigLocalAddress and tunnelInetConfigRemoteAddress exceeds 110 then OIDs of column instances in this table will have more than 128 sub-identifiers and cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3. In practice this is not expected to be a problem since IPv4 and IPv6 addresses will not cause the limit to be reached, but if other types are supported by an agent, care must be taken to ensure that the sum of the lengths do not cause the limit to be exceeded.
1.3.6.1.2.1.10.131.1.1.3.1not-accessiblecurrent
tunnelInetConfigAddressType
OBJECT-TYPE
The address type over which the tunnel encapsulates packets.
1.3.6.1.2.1.10.131.1.1.3.1.1InetAddressTypenot-accessiblecurrent
tunnelInetConfigLocalAddress
OBJECT-TYPE
The address of the local endpoint of the tunnel, or 0.0.0.0 (for IPv4) or :: (for IPv6) if the device is free to choose any of its addresses at tunnel establishment time.
1.3.6.1.2.1.10.131.1.1.3.1.2InetAddressnot-accessiblecurrent
tunnelInetConfigRemoteAddress
OBJECT-TYPE
The address of the remote endpoint of the tunnel.
1.3.6.1.2.1.10.131.1.1.3.1.3InetAddressnot-accessiblecurrent
tunnelInetConfigEncapsMethod
OBJECT-TYPE
The encapsulation method used by the tunnel.
1.3.6.1.2.1.10.131.1.1.3.1.4IANAtunnelTypenot-accessiblecurrent
tunnelInetConfigID
OBJECT-TYPE
An identifier used to distinguish between multiple tunnels of the same encapsulation method, with the same endpoints. If the encapsulation protocol only allows one tunnel per set of endpoint addresses (such as for GRE or IP-in-IP), the value of this object is 1. For encapsulation methods (such as L2F) which allow multiple parallel tunnels, the manager is responsible for choosing any ID which does not conflict with an existing row, such as choosing a random number.
1.3.6.1.2.1.10.131.1.1.3.1.5Integer32 (1..2147483647)not-accessiblecurrent
tunnelInetConfigIfIndex
OBJECT-TYPE
If the value of tunnelInetConfigStatus for this row is active, then this object contains the value of ifIndex corresponding to the tunnel interface. A value of 0 is not legal in the active state, and means that the interface index has not yet been assigned.
1.3.6.1.2.1.10.131.1.1.3.1.6InterfaceIndexOrZeroread-onlycurrent
tunnelInetConfigStatus
OBJECT-TYPE
The status of this row, by which new entries may be created, or old entries deleted from this table. The agent need not support setting this object to createAndWait or notInService since there are no other writable objects in this table, and writable objects in rows of corresponding tables such as the tunnelIfTable may be modified while this row is active. To create a row in this table for an encapsulation method which does not support multiple parallel tunnels with the same endpoints, the management station should simply use a tunnelInetConfigID of 1, and set tunnelInetConfigStatus to createAndGo. For encapsulation methods such as L2F which allow multiple parallel tunnels, the management station may select a pseudo-random number to use as the tunnelInetConfigID and set tunnelInetConfigStatus to createAndGo. In the event that this ID is already in use and an inconsistentValue is returned in response to the set operation, the management station should simply select a new pseudo-random number and retry the operation. Creating a row in this table will cause an interface index to be assigned by the agent in an implementation-dependent manner, and corresponding rows will be instantiated in the ifTable and the tunnelIfTable. The status of this row will become active as soon as the agent assigns the interface index, regardless of whether the interface is operationally up. Deleting a row in this table will likewise delete the corresponding row in the ifTable and in the tunnelIfTable.
1.3.6.1.2.1.10.131.1.1.3.1.7RowStatusread-createcurrent
tunnelInetConfigStorageType
OBJECT-TYPE
The storage type of this row. If the row is permanent(4), no objects in the row need be writable.
1.3.6.1.2.1.10.131.1.1.3.1.8StorageTyperead-createcurrent
tunnelMIBConformance
OBJECT-IDENTITY
1.3.6.1.2.1.10.131.2
tunnelMIBCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.10.131.2.1
tunnelMIBGroups
OBJECT-IDENTITY
1.3.6.1.2.1.10.131.2.2

Conformance

NameOIDStatus
tunnelMIBCompliance
MODULE-COMPLIANCE
The (deprecated) IPv4-only compliance statement for the IP Tunnel MIB. This is deprecated in favor of tunnelMIBInetFullCompliance and tunnelMIBInetReadOnlyCompliance.
1.3.6.1.2.1.10.131.2.1.1deprecated
tunnelMIBInetFullCompliance
MODULE-COMPLIANCE
The full compliance statement for the IP Tunnel MIB.
1.3.6.1.2.1.10.131.2.1.2current
tunnelMIBInetReadOnlyCompliance
MODULE-COMPLIANCE
The read-only compliance statement for the IP Tunnel MIB.
1.3.6.1.2.1.10.131.2.1.3current
tunnelMIBBasicGroup
OBJECT-GROUP
A collection of objects to support basic management of IPv4 Tunnels. Since this group cannot support IPv6, it is deprecated in favor of tunnelMIBInetGroup.
1.3.6.1.2.1.10.131.2.2.1deprecated
tunnelMIBInetGroup
OBJECT-GROUP
A collection of objects to support basic management of IPv4 and IPv6 Tunnels.
1.3.6.1.2.1.10.131.2.2.2current