2019-09-27 09:30, 2019-06-18 09:30, 2019-05-07 12:50, 2019-05-06 10:30, 2019-01-17 10:30, 2018-07-13 14:30, 2018-05-10 14:30, 2018-05-08 13:30, 2018-04-30 15:30, 2018-04-25 13:30, 2018-03-19 07:30, 2018-01-15 11:30, 2017-12-29 13:30, 2017-11-30 11:30, 2017-09-29 08:00, 2017-08-30 09:00, 2017-07-31 09:00, 2017-05-23 14:23, 2017-04-19 22:30, 2017-04-03 15:33, 2017-02-28 16:00, 2017-01-17 12:50, 2016-07-11 12:15, 2016-06-22 11:15, 2016-03-16 12:10, 2016-02-02 11:15, 2016-01-25 12:30, 2016-01-20 12:00, 2016-01-08 11:40, 2015-11-25 13:00, 2015-11-10 13:00, 2015-10-16 12:30, 2015-08-19 12:00, 2014-12-04 10:00, 2014-04-14 09:00
Namespace
poweralert
Source file
TRIPPLITE-PRODUCTS
Digest
sha256:22f1835a07a060b4d62184d65dc58d1dc3cdbaf2f8a2823a679950e5acdae511

Description

This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripp Lite PowerAlert and related software.

Contact

Software Engineering Tripp Lite 1111 W. 35th St. Chicago, IL 60609

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-MIBsysUpTime
SNMPv2-SMIGauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TimeStamp, TruthValue
TRIPPLITEtripplite

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TRIPPLITE
TRIPPLITE-PRODUCTS

Objects

NameOIDSyntaxAccessStatus
tlpHardware
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1
tlpDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.1
tlpDeviceNumDevices
OBJECT-TYPE
The number of devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.1.1Unsigned32read-onlycurrent
tlpDeviceTable
OBJECT-TYPE
A list of device table entries. The number of entries is given by the value of tlpDevicesNumDevices.
1.3.6.1.4.1.850.1.1.1.2not-accessiblecurrent
tlpDeviceEntry
OBJECT-TYPE
An entry containing information applicable to a particular device managed by this agent.
1.3.6.1.4.1.850.1.1.1.2.1not-accessiblecurrent
tlpDeviceIndex
OBJECT-TYPE
The table row index for the device.
1.3.6.1.4.1.850.1.1.1.2.1.1Unsigned32read-onlycurrent
tlpDeviceRowStatus
OBJECT-TYPE
Used with table edits to indicate the status of a given row in tlpDeviceTable.
1.3.6.1.4.1.850.1.1.1.2.1.2RowStatusread-onlycurrent
tlpDeviceType
OBJECT-TYPE
The type of device. One of the appropriate hardware types: ups, pdu, envirosense, etc.
1.3.6.1.4.1.850.1.1.1.2.1.3OBJECT IDENTIFIERread-onlycurrent
tlpDeviceManufacturer
OBJECT-TYPE
The name of the manufacturer.
1.3.6.1.4.1.850.1.1.1.2.1.4DisplayStringread-onlycurrent
tlpDeviceModel
OBJECT-TYPE
The model designation.
1.3.6.1.4.1.850.1.1.1.2.1.5DisplayStringread-onlycurrent
tlpDeviceName
OBJECT-TYPE
A user-supplied name for the device.
1.3.6.1.4.1.850.1.1.1.2.1.6DisplayStringread-writecurrent
tlpDeviceID
OBJECT-TYPE
A user-supplied ID for the device.
1.3.6.1.4.1.850.1.1.1.2.1.7INTEGER (0..65535)read-writecurrent
tlpDeviceLocation
OBJECT-TYPE
A user-supplied location for the device.
1.3.6.1.4.1.850.1.1.1.2.1.8DisplayStringread-writecurrent
tlpDeviceRegion
OBJECT-TYPE
A user-supplied region for the device.
1.3.6.1.4.1.850.1.1.1.2.1.9DisplayStringread-writecurrent
tlpDeviceStatus
OBJECT-TYPE
The currently most critical alarm status for the device.
1.3.6.1.4.1.850.1.1.1.2.1.10INTEGER {none(0), critical(1), warning(2), info(3), status(4), offline(5), custom(6), configuration(7)}read-onlycurrent
tlpDeviceDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.2
tlpDeviceIdentTable
OBJECT-TYPE
The identity details of each device in device table. The number of entries is given by the value of tlpDevicesNumDevices.
1.3.6.1.4.1.850.1.1.2.1not-accessiblecurrent
tlpDeviceIdentEntry
OBJECT-TYPE
An entry containing details for a particular device.
1.3.6.1.4.1.850.1.1.2.1.1not-accessiblecurrent
tlpDeviceIdentProtocol
OBJECT-TYPE
The Tripplite protocol used to communicate with the device.
1.3.6.1.4.1.850.1.1.2.1.1.1DisplayStringread-onlycurrent
tlpDeviceIdentCommPortType
OBJECT-TYPE
The type of communications port used to connect with the device.
1.3.6.1.4.1.850.1.1.2.1.1.2INTEGER {unknown(0), serial(1), usb(2), hid(3), simulated(4), unittest(5)}read-onlycurrent
tlpDeviceIdentCommPortName
OBJECT-TYPE
The name of the communications port.
1.3.6.1.4.1.850.1.1.2.1.1.3DisplayStringread-onlycurrent
tlpDeviceIdentFirmwareVersion
OBJECT-TYPE
The firmware version of the device.
1.3.6.1.4.1.850.1.1.2.1.1.4DisplayStringread-onlycurrent
tlpDeviceIdentSerialNum
OBJECT-TYPE
The serial number of the device.
1.3.6.1.4.1.850.1.1.2.1.1.5DisplayStringread-onlycurrent
tlpDeviceIdentDateInstalled
OBJECT-TYPE
The installation date for this device in the format of mm/dd/yyyy.
1.3.6.1.4.1.850.1.1.2.1.1.6DisplayStringread-writecurrent
tlpDeviceIdentHardwareVersion
OBJECT-TYPE
The hardware revision of the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
1.3.6.1.4.1.850.1.1.2.1.1.7DisplayStringread-onlycurrent
tlpDeviceIdentCurrentUptime
OBJECT-TYPE
The device uptime since its last startup. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
1.3.6.1.4.1.850.1.1.2.1.1.8DisplayStringread-onlycurrent
tlpDeviceIdentTotalUptime
OBJECT-TYPE
The cumulative (total) uptime for the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
1.3.6.1.4.1.850.1.1.2.1.1.9DisplayStringread-onlycurrent
tlpDeviceIdentFirmwareVersion2
OBJECT-TYPE
The firmware version of second IC on the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
1.3.6.1.4.1.850.1.1.2.1.1.10DisplayStringread-onlycurrent
tlpDeviceIdentFirmwareVersion3
OBJECT-TYPE
The firmware version of third IC on the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
1.3.6.1.4.1.850.1.1.2.1.1.11DisplayStringread-onlycurrent
tlpDeviceIdentNvrID
OBJECT-TYPE
The id of NVRAM. This value will return ERROR_NO_SUCH_NAME if not supported by the device.
1.3.6.1.4.1.850.1.1.2.1.1.12DisplayStringread-onlycurrent
tlpDeviceTypes
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3
tlpUps
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1
tlpUpsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.1
tlpUpsIdentNumUps
OBJECT-TYPE
The number of ups devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.1.1.1Unsigned32read-onlycurrent
tlpUpsIdentTable
OBJECT-TYPE
The identity details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
1.3.6.1.4.1.850.1.1.3.1.1.2not-accessiblecurrent
tlpUpsIdentEntry
OBJECT-TYPE
An entry containing details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1not-accessiblecurrent
tlpUpsIdentNumInputs
OBJECT-TYPE
The number of input lines supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.1Unsigned32read-onlycurrent
tlpUpsIdentNumOutputs
OBJECT-TYPE
The number of output lines supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.2Unsigned32read-onlycurrent
tlpUpsIdentNumBypass
OBJECT-TYPE
The number of bypass lines supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.3Unsigned32read-onlycurrent
tlpUpsIdentNumPhases
OBJECT-TYPE
The number of phases supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.4Unsigned32read-onlycurrent
tlpUpsIdentNumOutlets
OBJECT-TYPE
The number of receptacles supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.5Unsigned32read-onlycurrent
tlpUpsIdentNumOutletGroups
OBJECT-TYPE
The number of receptacle groups supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.6Unsigned32read-onlycurrent
tlpUpsIdentNumBatteryPacks
OBJECT-TYPE
The number of battery packs, internal and external combined, supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.7Unsigned32read-onlycurrent
tlpUpsIdentNumFans
OBJECT-TYPE
The number of fans supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.8Unsigned32read-onlycurrent
tlpUpsIdentNumHeatsinks
OBJECT-TYPE
The number of heatsink thermistors supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.9Unsigned32read-onlycurrent
tlpUpsIdentNumInputContacts
OBJECT-TYPE
The number of input contacts supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.10Unsigned32read-onlycurrent
tlpUpsIdentNumOutputContacts
OBJECT-TYPE
The number of output contacts supported by the ups.
1.3.6.1.4.1.850.1.1.3.1.1.2.1.11Unsigned32read-onlycurrent
tlpUpsSupportsTable
OBJECT-TYPE
The supported details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
1.3.6.1.4.1.850.1.1.3.1.1.3not-accessiblecurrent
tlpUpsSupportsEntry
OBJECT-TYPE
An entry containing supported details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.1.3.1not-accessiblecurrent
tlpUpsSupportsEnergywise
OBJECT-TYPE
Indicates whether the ups supports Cisco EnergyWise.
1.3.6.1.4.1.850.1.1.3.1.1.3.1.1TruthValueread-onlycurrent
tlpUpsSupportsRampShed
OBJECT-TYPE
Indicates whether the ups supports ramping and shedding.
1.3.6.1.4.1.850.1.1.3.1.1.3.1.2TruthValueread-onlycurrent
tlpUpsSupportsOutletGroup
OBJECT-TYPE
Indicates whether the ups supports outlet groups.
1.3.6.1.4.1.850.1.1.3.1.1.3.1.3TruthValueread-onlycurrent
tlpUpsSupportsOutletCurrentPower
OBJECT-TYPE
Indicates whether the ups reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletCurrent and tlpUpsOutletPower.
1.3.6.1.4.1.850.1.1.3.1.1.3.1.4TruthValueread-onlycurrent
tlpUpsSupportsOutletVoltage
OBJECT-TYPE
Indicates whether the ups reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletVoltage.
1.3.6.1.4.1.850.1.1.3.1.1.3.1.5TruthValueread-onlycurrent
tlpUpsDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.2
tlpUpsDeviceTable
OBJECT-TYPE
The device details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
1.3.6.1.4.1.850.1.1.3.1.2.1not-accessiblecurrent
tlpUpsDeviceEntry
OBJECT-TYPE
An entry containing device details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.2.1.1not-accessiblecurrent
tlpUpsDeviceMainLoadState
OBJECT-TYPE
The current state of the main output of the device.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.1INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlpUpsDeviceMainLoadControllable
OBJECT-TYPE
Indicates whether or not the main output is controllable, and whether the ups can be turned off and on.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.2TruthValueread-onlycurrent
tlpUpsDeviceMainLoadCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.3INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpUpsDevicePowerOnDelay
OBJECT-TYPE
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.4Integer32read-writecurrent
tlpUpsDeviceTestDate
OBJECT-TYPE
The date of the last self-test run on the ups, in the format YYYY-MM-DD.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.5DisplayStringread-onlycurrent
tlpUpsDeviceTestResultsStatus
OBJECT-TYPE
The result of the last self-test run on the ups.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.6INTEGER {noTest(0), doneAndPassed(1), doneAndWarning(2), doneAndError(3), aborted(4), inProgress(5), noTestInitiated(6), badBattery(7), overCurrent(8), batteryFailed(9)}read-onlycurrent
tlpUpsDeviceTemperatureC
OBJECT-TYPE
The ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.7Integer32read-onlycurrent
tlpUpsDeviceTemperatureF
OBJECT-TYPE
The ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.8Integer32read-onlycurrent
tlpUpsDeviceLastACFailureReason
OBJECT-TYPE
The last AC failure reason.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.9INTEGER {noACFailureSinceReset(0), blackout(1), instantaneousHighLineFrequency(2), highLineVoltage(3), lowLineVoltage(4), averageFrequencyFault(5), instantaneousLowLineFrequency(6), delayedBrownout(7)}read-onlycurrent
tlpUpsDeviceLastShutdownReason
OBJECT-TYPE
The last unit shut down reason.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.10INTEGER {noShutdownSinceReset(0), onOffButtonShutdown(1), averageVbattSmallerThenLVCShutdown(2), fastVbattKeepaliveVoltageFastShutdown(3), averageCurrentLimitShutdown(4), fastCurrentLimitShutdown(5), heavyLoadThermalTimeLimitShutdown(6), fixedInvertModeTimeLimitShutdown(7), highBatteryVoltageFault(8), averageVbattKeepaliveVoltageShutdown(9), shutdownCommandWithAutorestartEnabled(10), shutdownCommandWithoutAutorestartEnabled(11), lineConnectRelayFault(12), epoInvertMode(13), epoRebootMode(14), invalidLineStandbyMode(15), chargerLimitMinBatteryVoltage(16), chargerLimitMaxBatteryVoltage(17), invalidLineDelayedWakeupAutorestartEnabled(18), invalidLineDelayedWakeupAutorestartDisabled(19), minBatteryVoltagePriorDelayedWakeupAutorestartEnabled(20), minBatteryVoltagePriorDelayedWakeupAutorestartDisabled(21), lvcShutdownAutorestartEnabled(22), lvcShutdownAutorestartDisabled(23), overloadShutdownAutorestartEnabled(24), overloadShutdownAutorestartDisabled(25), overTemperatureShutdownAutorestartEnabled(26), overTemperatureShutdownAutorestartDisabled(27), onOffButtonShutdownAutorestartEnabled(28), onOffButtonShutdownAutorestartDisabled(29), batteryReportedFault(30), batteryCommunicationLost(31), batteryJumpStartChargerTimeoutError(32)}read-onlycurrent
tlpUpsDeviceOutputCurrentPrecision
OBJECT-TYPE
Output current is reported by tlpUpsOutputLineCurrent, tlpUpsOutputLineCurrentMin and tlpUpsOutputLineCurrentMax. These values are all reported in hundredths(0.01A),which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpUpsOutputLineCurrent reports 530 and tlpUpsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.
1.3.6.1.4.1.850.1.1.3.1.2.1.1.11INTEGER {wholeNumber(0), tenths(1), hundredths(2)}read-onlycurrent
tlpUpsDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3
tlpUpsBattery
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.1
tlpUpsBatterySummaryTable
OBJECT-TYPE
The battery system summary of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.1.1not-accessiblecurrent
tlpUpsBatterySummaryEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery system managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1not-accessiblecurrent
tlpUpsBatteryStatus
OBJECT-TYPE
The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than tlpUpsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to tlpUpsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.1INTEGER {unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4)}read-onlycurrent
tlpUpsSecondsOnBattery
OBJECT-TYPE
If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.2Unsigned32read-onlycurrent
tlpUpsEstimatedMinutesRemaining
OBJECT-TYPE
An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.3Unsigned32read-onlycurrent
tlpUpsEstimatedChargeRemaining
OBJECT-TYPE
An estimate of the battery charge remaining expressed as a percent of full charge.
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.4INTEGER (0..100)read-onlycurrent
tlpUpsBatteryRunTimeRemaining
OBJECT-TYPE
The run time remaining before batteries are exhausted. If the device does not support run time remaining, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.5TimeTicksread-onlycurrent
tlpUpsBatteryTotalMinutesOnBattery
OBJECT-TYPE
The total accumulative minutes the ups has run on the battery.
1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.6Unsigned32read-onlycurrent
tlpUpsBatteryDetailTable
OBJECT-TYPE
The battery detail of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.1.2not-accessiblecurrent
tlpUpsBatteryDetailEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery system managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.1.2.1not-accessiblecurrent
tlpUpsBatteryDetailVoltage
OBJECT-TYPE
The magnitude of the present battery voltage.
1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.1Unsigned32read-onlycurrent
tlpUpsBatteryDetailCurrent
OBJECT-TYPE
The present battery current.
1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.2Integer32read-onlycurrent
tlpUpsBatteryDetailCapacity
OBJECT-TYPE
The estimated remaining battery capacity expressed as a percent of full capacity.
1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.3INTEGER (0..100)read-onlycurrent
tlpUpsBatteryDetailCharge
OBJECT-TYPE
Denotes the charge state of the battery.
1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.4INTEGER {floating(0), charging(1), resting(2), discharging(3), normal(4), standby(5)}read-onlycurrent
tlpUpsBatteryDetailChargerStatus
OBJECT-TYPE
The status of the battery charger. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.5INTEGER {ok(0), inFaultCondition(1)}read-onlycurrent
tlpUpsBatteryPackIdentTable
OBJECT-TYPE
The battery identification details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks.
1.3.6.1.4.1.850.1.1.3.1.3.1.3not-accessiblecurrent
tlpUpsBatteryPackIdentEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery pack managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1not-accessiblecurrent
tlpUpsBatteryPackIdentIndex
OBJECT-TYPE
The table row index for the ups battery pack.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.1Unsigned32read-onlycurrent
tlpUpsBatteryPackIdentManufacturer
OBJECT-TYPE
The manufacturer of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.2DisplayStringread-onlycurrent
tlpUpsBatteryPackIdentModel
OBJECT-TYPE
The model or device name of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.3DisplayStringread-onlycurrent
tlpUpsBatteryPackIdentSerialNum
OBJECT-TYPE
The serial number of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.4DisplayStringread-onlycurrent
tlpUpsBatteryPackIdentFirmware
OBJECT-TYPE
The firmware of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.5DisplayStringread-onlycurrent
tlpUpsBatteryPackIdentSKU
OBJECT-TYPE
The SKU of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.6DisplayStringread-onlycurrent
tlpUpsBatteryPackConfigTable
OBJECT-TYPE
The battery configuration details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks.
1.3.6.1.4.1.850.1.1.3.1.3.1.4not-accessiblecurrent
tlpUpsBatteryPackConfigEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery pack managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1not-accessiblecurrent
tlpUpsBatteryPackConfigChemistry
OBJECT-TYPE
The type of battery pack.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.1INTEGER {unknown(0), leadAcid(1), nickelCadmium(2), lithiumIon(3)}read-onlycurrent
tlpUpsBatteryPackConfigStyle
OBJECT-TYPE
The style of battery pack.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.2INTEGER {unknown(0), nonsmart(1), smart(2), bms(3)}read-onlycurrent
tlpUpsBatteryPackConfigLocation
OBJECT-TYPE
The location of the battery pack.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.3INTEGER {unknown(0), internal(1), external(2)}read-onlycurrent
tlpUpsBatteryPackConfigStrings
OBJECT-TYPE
The number of series strings in parallel contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.4Unsigned32read-onlycurrent
tlpUpsBatteryPackConfigBatteriesPerString
OBJECT-TYPE
The number of battery per each string in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.5Unsigned32read-onlycurrent
tlpUpsBatteryPackConfigCellsPerBattery
OBJECT-TYPE
The number of cells per battery..
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.6INTEGER {unknown(0), one(1), two(2), four(4), six(6)}read-onlycurrent
tlpUpsBatteryPackConfigNumBatteries
OBJECT-TYPE
The total number of batteries contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.7Unsigned32read-onlycurrent
tlpUpsBatteryPackConfigCapacityUnits
OBJECT-TYPE
The units of measurement used for tlpUpsBatteryPackConfigDesignCapacity and tlpUpsBatteryPackConfigCellCapacity. If supported, this value will report either mAHR(1), amps per hour, or mWhr(1), watts per hour. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.8INTEGER {mAHr(0), mWHr(1)}read-onlycurrent
tlpUpsBatteryPackConfigDesignCapacity
OBJECT-TYPE
The theoretical or nominal capacity of the battery pack in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.9Unsigned32read-onlycurrent
tlpUpsBatteryPackConfigCellCapacity
OBJECT-TYPE
The capacity of the batteries in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.10Unsigned32read-onlycurrent
tlpUpsBatteryPackConfigMinCellVoltage
OBJECT-TYPE
The minimum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.11Unsigned32read-onlycurrent
tlpUpsBatteryPackConfigMaxCellVoltage
OBJECT-TYPE
The maximum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.12Unsigned32read-onlycurrent
tlpUpsBatteryPackDetailTable
OBJECT-TYPE
The details of each battery pack for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss and battery packs managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumBatteryPacks.
1.3.6.1.4.1.850.1.1.3.1.3.1.5not-accessiblecurrent
tlpUpsBatteryPackDetailEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery system managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1not-accessiblecurrent
tlpUpsBatteryPackDetailCondition
OBJECT-TYPE
The condition of the battery. A bad battery should be replaced.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.1INTEGER {unknown(0), good(1), weak(2), bad(3)}read-onlycurrent
tlpUpsBatteryPackDetailTemperatureC
OBJECT-TYPE
The ambient temperature at or near the UPS Battery casing.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.2Unsigned32read-onlycurrent
tlpUpsBatteryPackDetailTemperatureF
OBJECT-TYPE
The ambient temperature at or near the UPS Battery casing.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.3Unsigned32read-onlycurrent
tlpUpsBatteryPackDetailAge
OBJECT-TYPE
The age of the battery in years. This is equal to the current date minus tlpUpsBatteryPackIdentInstallDate.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.4Unsigned32read-onlycurrent
tlpUpsBatteryPackDetailLastReplaceDate
OBJECT-TYPE
The date when the batteries were last replaced in YYYYMMDD format.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.5DisplayStringread-writecurrent
tlpUpsBatteryPackDetailNextReplaceDate
OBJECT-TYPE
The date when the batteries should next be replaced in YYYYMMDD format.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.6DisplayStringread-onlycurrent
tlpUpsBatteryPackDetailCycleCount
OBJECT-TYPE
The number of times the battery went into invert mode. This number is incremented by 1 each time the unit goes on battery mode (with the exception of Self Test mode). If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.7Unsigned32read-onlycurrent
tlpUpsInput
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.2
tlpUpsInputTable
OBJECT-TYPE
The input details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.2.1not-accessiblecurrent
tlpUpsInputEntry
OBJECT-TYPE
An entry containing information applicable to all input lines per each ups managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1not-accessiblecurrent
tlpUpsInputLineBads
OBJECT-TYPE
A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. This value is not supported on all units. If the ups does not support this value, then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.1INTEGERread-onlycurrent
tlpUpsInputNominalVoltage
OBJECT-TYPE
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.2Unsigned32read-onlycurrent
tlpUpsInputNominalFrequency
OBJECT-TYPE
The nominal value of the input line frequency. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.3Unsigned32read-onlycurrent
tlpUpsInputLowTransferVoltage
OBJECT-TYPE
The minimum line voltage allowed before the ups system transfers to battery backup.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.4Unsigned32read-onlycurrent
tlpUpsInputLowTransferVoltageLowerBound
OBJECT-TYPE
The lower boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.5Unsigned32read-onlycurrent
tlpUpsInputLowTransferVoltageUpperBound
OBJECT-TYPE
The upper boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.6Unsigned32read-onlycurrent
tlpUpsInputHighTransferVoltage
OBJECT-TYPE
The maximum line voltage allowed before the ups system transfers to battery backup.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.7Unsigned32read-onlycurrent
tlpUpsInputHighTransferVoltageLowerBound
OBJECT-TYPE
The lower boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.8Unsigned32read-onlycurrent
tlpUpsInputHighTransferVoltageUpperBound
OBJECT-TYPE
The upper boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.9Unsigned32read-onlycurrent
tlpUpsInputWattHours
OBJECT-TYPE
The number of watt hours of energy utilized in the past 24 hours. Use tlpUpsControlResetWattHours to reset the watt hours calculation algorithm.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.10Unsigned32read-onlycurrent
tlpUpsInputLowTransferVoltageResetTolerance
OBJECT-TYPE
If a unit is transferred to battery backup due to under-voltage, the line voltage has to rise above this value from tlpUpsConfigLowVoltageTransfer, before the unit switched back to the AC input.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.11Unsigned32read-onlycurrent
tlpUpsInputHighTransferVoltageResetTolerance
OBJECT-TYPE
If an input transferred to battery backup due to over-voltage, the line voltage on the input source has to fall below this value from tlpUpsConfigHighVoltageTransfer, before the unit switched back to the AC input.
1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.12Unsigned32read-onlycurrent
tlpUpsInputPhaseTable
OBJECT-TYPE
The input phase details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumPhases.
1.3.6.1.4.1.850.1.1.3.1.3.2.2not-accessiblecurrent
tlpUpsInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1not-accessiblecurrent
tlpUpsInputPhaseIndex
OBJECT-TYPE
The table row index for the ups input phase.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.1Unsigned32read-onlycurrent
tlpUpsInputPhaseFrequency
OBJECT-TYPE
The present input frequency for a given input line.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.2Unsigned32read-onlycurrent
tlpUpsInputPhaseVoltage
OBJECT-TYPE
The magnitude of the present input voltage for a given input line.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3Unsigned32read-onlycurrent
tlpUpsInputPhaseVoltageMin
OBJECT-TYPE
The minimum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.4Unsigned32read-writecurrent
tlpUpsInputPhaseVoltageMax
OBJECT-TYPE
The maximum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.5Unsigned32read-writecurrent
tlpUpsInputPhaseCurrent
OBJECT-TYPE
The magnitude of the present input current.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.6Unsigned32read-onlycurrent
tlpUpsInputPhasePower
OBJECT-TYPE
The magnitude of the present input true power.
1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.7Unsigned32read-onlycurrent
tlpUpsOutput
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.3
tlpUpsOutputTable
OBJECT-TYPE
The output details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.3.1not-accessiblecurrent
tlpUpsOutputEntry
OBJECT-TYPE
An entry containing information applicable to a particular output line managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.3.1.1not-accessiblecurrent
tlpUpsOutputSource
OBJECT-TYPE
The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.1INTEGER {unknown(0), other(1), none(2), normal(3), bypass(4), battery(5), boosting(6), reducing(7), second(8), economy(9), testing(10)}read-onlycurrent
tlpUpsOutputNominalVoltage
OBJECT-TYPE
The nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.2Unsigned32read-onlycurrent
tlpUpsOutputFrequency
OBJECT-TYPE
The present output frequency. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a common frequency is supported by the ups, then this frequency will contain the common frequency value. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.3Unsigned32read-onlycurrent
tlpUpsOutputVARating
OBJECT-TYPE
The VA Rating of the ups. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.4Unsigned32read-onlycurrent
tlpUpsOutputPowerFactor
OBJECT-TYPE
The percentage of output power factor.
1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.5Unsigned32read-onlycurrent
tlpUpsOutputLineTable
OBJECT-TYPE
The output line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.3.2not-accessiblecurrent
tlpUpsOutputLineEntry
OBJECT-TYPE
An entry containing information applicable to a particular output line managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1not-accessiblecurrent
tlpUpsOutputLineIndex
OBJECT-TYPE
The table row index for the ups output line.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.1Unsigned32read-onlycurrent
tlpUpsOutputLineVoltage
OBJECT-TYPE
The magnitude of the present output voltage for a given output line.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2Unsigned32read-onlycurrent
tlpUpsOutputLineCurrent
OBJECT-TYPE
The output current, in hundredths of amps, for a given line. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpUpsDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3Unsigned32read-onlycurrent
tlpUpsOutputLinePower
OBJECT-TYPE
The present output true power.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4Unsigned32read-onlycurrent
tlpUpsOutputLinePercentLoad
OBJECT-TYPE
The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.5INTEGER (0..200)read-onlycurrent
tlpUpsOutputLineFrequency
OBJECT-TYPE
The present output frequency on this output line. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a per line frequency is supported by the ups, then this frequency value will reports the value of this line. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.6Unsigned32read-onlycurrent
tlpUpsOutputLineApparentPower
OBJECT-TYPE
The present output apparent power.
1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.9Unsigned32read-onlycurrent
tlpUpsBypass
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.4
tlpUpsBypassTable
OBJECT-TYPE
The bypass details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.4.1not-accessiblecurrent
tlpUpsBypassEntry
OBJECT-TYPE
An entry containing information applicable to all input lines per each ups managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.4.1.1not-accessiblecurrent
tlpUpsBypassFrequency
OBJECT-TYPE
The present bypass frequency.
1.3.6.1.4.1.850.1.1.3.1.3.4.1.1.1Unsigned32read-onlycurrent
tlpUpsBypassLineTable
OBJECT-TYPE
The bypass line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.4.2not-accessiblecurrent
tlpUpsBypassLineEntry
OBJECT-TYPE
An entry containing information applicable to a particular bypass line managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.4.2.1not-accessiblecurrent
tlpUpsBypassLineIndex
OBJECT-TYPE
The bypass line identifier.
1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.1Unsigned32read-onlycurrent
tlpUpsBypassLineVoltage
OBJECT-TYPE
The present bypass voltage.
1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.2Unsigned32read-onlycurrent
tlpUpsBypassLineCurrent
OBJECT-TYPE
The present bypass current.
1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.3Unsigned32read-onlycurrent
tlpUpsBypassLinePower
OBJECT-TYPE
The present true power conveyed by the bypass.
1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.4Unsigned32read-onlycurrent
tlpUpsOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.5
tlpUpsOutletTable
OBJECT-TYPE
The details of each ups outlet in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.3.5.1not-accessiblecurrent
tlpUpsOutletEntry
OBJECT-TYPE
An entry containing information applicable to a particular outlet managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1not-accessiblecurrent
tlpUpsOutletIndex
OBJECT-TYPE
The table row index for the ups outlet.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.1Unsigned32read-onlycurrent
tlpUpsOutletName
OBJECT-TYPE
A user-definable string identifying the name of the outlet.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.2DisplayStringread-writecurrent
tlpUpsOutletDescription
OBJECT-TYPE
A user-definable string identifying the device(s) connected to the given outlet.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.3DisplayStringread-writecurrent
tlpUpsOutletState
OBJECT-TYPE
The current state of the outlet.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.4INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlpUpsOutletControllable
OBJECT-TYPE
Denotes whether this outlet is controllable.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.5TruthValueread-onlycurrent
tlpUpsOutletCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.6INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpUpsOutletVoltage
OBJECT-TYPE
The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpUpsSupportsOutletVoltage.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.7Unsigned32read-onlycurrent
tlpUpsOutletCurrent
OBJECT-TYPE
The present output current, in hundredths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpUpsSupportsCurrentPower.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.8Unsigned32read-onlycurrent
tlpUpsOutletPower
OBJECT-TYPE
The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpUpsSupportsCurrentPower.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.9Unsigned32read-onlycurrent
tlpUpsOutletRampAction
OBJECT-TYPE
The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.10INTEGER {remainOff(0), turnOnAfterDelay(1)}read-writecurrent
tlpUpsOutletRampDelay
OBJECT-TYPE
The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.11Integer32read-writecurrent
tlpUpsOutletShedAction
OBJECT-TYPE
The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.12INTEGER {remainOn(0), turnOffAfterDelay(1)}read-writecurrent
tlpUpsOutletShedDelay
OBJECT-TYPE
The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.13Integer32read-writecurrent
tlpUpsOutletGroup
OBJECT-TYPE
The tlpUpsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.
1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.14Integer32read-writecurrent
tlpUpsOutletGroupTable
OBJECT-TYPE
The receptacle grouping details of each ups in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpUpsIdentNumOutletGroups per each device.
1.3.6.1.4.1.850.1.1.3.1.3.5.2not-accessiblecurrent
tlpUpsOutletGroupEntry
OBJECT-TYPE
An entry containing information applicable to a particular outlet group managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1not-accessiblecurrent
tlpUpsOutletGroupIndex
OBJECT-TYPE
The table row index for the ups outlet group.
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.1Unsigned32read-onlycurrent
tlpUpsOutletGroupRowStatus
OBJECT-TYPE
Row status for the tlpUpsOutletGroupTable
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.2RowStatusread-writecurrent
tlpUpsOutletGroupName
OBJECT-TYPE
The name of this outlet group.
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.3DisplayStringread-writecurrent
tlpUpsOutletGroupDescription
OBJECT-TYPE
A description for this outlet group.
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.4DisplayStringread-writecurrent
tlpUpsOutletGroupState
OBJECT-TYPE
The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.5INTEGER {unknown(0), off(1), on(2), mixed(3)}read-onlycurrent
tlpUpsOutletGroupCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.
1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.6INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpUpsWatchdog
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.6
tlpUpsWatchdogTable
OBJECT-TYPE
The watchdog details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
1.3.6.1.4.1.850.1.1.3.1.3.6.1not-accessiblecurrent
tlpUpsWatchdogEntry
OBJECT-TYPE
An entry containing watchdog details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.3.6.1.1not-accessiblecurrent
tlpUpsWatchdogSupported
OBJECT-TYPE
Indicates whether or not this ups supports a watchdog reboot.
1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.1TruthValueread-onlycurrent
tlpUpsWatchdogSecsBeforeReboot
OBJECT-TYPE
The maximum number of seconds that can expire between polls that the engine makes to the ups for data. If this time runs out, then the ups will cycle its outputs. Set this to zero to turns disable this feature.
1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.2Unsigned32read-writecurrent
tlpUpsFan
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.7
tlpUpsFanTable
OBJECT-TYPE
The fan speed of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumFans.
1.3.6.1.4.1.850.1.1.3.1.3.7.1not-accessiblecurrent
tlpUpsFanEntry
OBJECT-TYPE
An entry containing information applicable to a particular fan managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.7.1.1not-accessiblecurrent
tlpUpsFanIndex
OBJECT-TYPE
The table row index for the ups fan speed.
1.3.6.1.4.1.850.1.1.3.1.3.7.1.1.1Unsigned32read-onlycurrent
tlpUpsFanSpeed
OBJECT-TYPE
The fan speed in rotations per minute.
1.3.6.1.4.1.850.1.1.3.1.3.7.1.1.2Unsigned32read-onlycurrent
tlpUpsHeatsink
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.8
tlpUpsHeatsinkTable
OBJECT-TYPE
A list of ups heatsink thermistor table entries. The number of entries is given by the value of tlpUpsIdentNumHeatsinks.
1.3.6.1.4.1.850.1.1.3.1.3.8.1not-accessiblecurrent
tlpUpsHeatsinkEntry
OBJECT-TYPE
An entry containing information applicable to a particular heatsink managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.3.8.1.1not-accessiblecurrent
tlpUpsHeatsinkIndex
OBJECT-TYPE
The table row index for the ups heatsink.
1.3.6.1.4.1.850.1.1.3.1.3.8.1.1.1Unsigned32read-onlycurrent
tlpUpsHeatsinkTemperatureC
OBJECT-TYPE
The temperature at the heatsink thermistor in tenths degrees Celsius. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.8.1.1.2Integer32read-onlycurrent
tlpUpsHeatsinkTemperatureF
OBJECT-TYPE
The temperature at the heatsink thermistor in tenths degrees Fahrenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.8.1.1.3Integer32read-onlycurrent
tlpUpsContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.9
tlpUpsInputContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.9.1
tlpUpsInputContactTable
OBJECT-TYPE
The input contact details of each ups in the device table. The number of entries is given by the value of tlpUpsIdentNumInputContacts.
1.3.6.1.4.1.850.1.1.3.1.3.9.1.1not-accessiblecurrent
tlpUpsInputContactEntry
OBJECT-TYPE
An entry containing input contact details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.3.9.1.1.1not-accessiblecurrent
tlpUpsInputContactIndex
OBJECT-TYPE
The table row index for the ups input contact details.
1.3.6.1.4.1.850.1.1.3.1.3.9.1.1.1.1Unsigned32read-onlycurrent
tlpUpsInputContactInAlarm
OBJECT-TYPE
The alarm status of the input contact. Input contacts are not supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.9.1.1.1.2INTEGER {notInAlarm(0), inAlarm(1)}read-onlycurrent
tlpUpsOutputContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.3.9.2
tlpUpsOutputContactTable
OBJECT-TYPE
The output contact details of each ups in the device table. The number of entries is given by the value of tlpUpsIdentNumOuputContacts.
1.3.6.1.4.1.850.1.1.3.1.3.9.2.1not-accessiblecurrent
tlpUpsOutputContactEntry
OBJECT-TYPE
An entry containing output contact details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.3.9.2.1.1not-accessiblecurrent
tlpUpsOutputContactIndex
OBJECT-TYPE
The table row index for the ups output contact details.
1.3.6.1.4.1.850.1.1.3.1.3.9.2.1.1.1Unsigned32read-onlycurrent
tlpUpsOutputContactInAlarm
OBJECT-TYPE
The alarm status of the output contact. Output contacts are not supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.3.9.2.1.1.2INTEGER {notInAlarm(0), inAlarm(1)}read-onlycurrent
tlpUpsControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.4
tlpUpsControlTable
OBJECT-TYPE
The actionable controls for each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
1.3.6.1.4.1.850.1.1.3.1.4.1not-accessiblecurrent
tlpUpsControlEntry
OBJECT-TYPE
An entry containing controls for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.4.1.1not-accessiblecurrent
tlpUpsControlSelfTest
OBJECT-TYPE
Set to TRUE to initiate a self test on the ups.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.1TruthValueread-writecurrent
tlpUpsControlRamp
OBJECT-TYPE
Set to TRUE to initiate the pre-designated ramp sequence on the ups.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.2TruthValueread-writecurrent
tlpUpsControlShed
OBJECT-TYPE
Set to TRUE to initiate the pre-designated shed sequence on the ups.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.3TruthValueread-writecurrent
tlpUpsControlUpsOn
OBJECT-TYPE
Set to TRUE to turn the ups on.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.4TruthValueread-writecurrent
tlpUpsControlUpsOff
OBJECT-TYPE
Set to TRUE to turn the ups off.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.5TruthValueread-writecurrent
tlpUpsControlUpsReboot
OBJECT-TYPE
Set to TRUE to reboot the ups.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.6TruthValueread-writecurrent
tlpUpsControlBypass
OBJECT-TYPE
This switches the ups in and out of bypass mode. This value returns the current bypass mode: disable(0) if the ups is not in bypass mode, enable(1) if the ups is in bypass mode. Set to disable(0) to exit bypass mode, or enable(1) to enter bypass mode. If switching bypass mode is not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.7INTEGER {disable(0), enable(1)}read-writecurrent
tlpUpsControlResetWattHours
OBJECT-TYPE
Set to TRUE to reset the tlpUpsInputWattHours calculation algorithm.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.8TruthValueread-writecurrent
tlpUpsControlCancelSelfTest
OBJECT-TYPE
Set to TRUE to cancel the self test in progress.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.9TruthValueread-writecurrent
tlpUpsControlResetAllParameters
OBJECT-TYPE
Set to TRUE to reset all configuration settings to the default values.
1.3.6.1.4.1.850.1.1.3.1.4.1.1.10TruthValueread-writecurrent
tlpUpsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.5
tlpUpsConfigTable
OBJECT-TYPE
The configuration details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
1.3.6.1.4.1.850.1.1.3.1.5.1not-accessiblecurrent
tlpUpsConfigEntry
OBJECT-TYPE
An entry containing information applicable to all input lines per each ups managed by this agent.
1.3.6.1.4.1.850.1.1.3.1.5.1.1not-accessiblecurrent
tlpUpsConfigInputVoltage
OBJECT-TYPE
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.1Unsigned32read-writecurrent
tlpUpsConfigInputFrequency
OBJECT-TYPE
The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.2Unsigned32read-writecurrent
tlpUpsConfigOutputVoltage
OBJECT-TYPE
The nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.3Unsigned32read-writecurrent
tlpUpsConfigOutputFrequency
OBJECT-TYPE
The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request will be rejected and the agent will respond with an appropriate error message.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.4Unsigned32read-writecurrent
tlpUpsConfigAudibleStatus
OBJECT-TYPE
The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self- describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.5INTEGER {disabled(1), enabled(2), muted(3)}read-writecurrent
tlpUpsConfigAutoBatteryTest
OBJECT-TYPE
When disabled(0), the ups will not perform an automatic battery selftest. When set to another value, the ups will perform an automatic selftest in the approximate period defined by each respective enumerated value. This feature is generally not recommended.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.6INTEGER {disabled(0), biweekly(1), monthly(2), quarterly(3), semiannually(4)}read-writecurrent
tlpUpsConfigAutoRestartAfterShutdown
OBJECT-TYPE
When enabled(1), the ups should autorestart after a shutdown from battery mode if valid AC is applied. When disabled(0), the ups should not autorestart when AC is restored and instead power up into standby mode.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.7INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigAutoRampOnTransition
OBJECT-TYPE
When enabled(1), the ups should perform its preconfigured ramp sequence when valid AC is restored while in battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.8INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigAutoShedOnTransition
OBJECT-TYPE
When enabled(1), the ups should perform its preconfigured shed sequence when valid AC is lost causing the ups to enter battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.9INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigBypassLowerLimitPercent
OBJECT-TYPE
The lowest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.10INTEGER (-20..-5)read-writecurrent
tlpUpsConfigBypassUpperLimitPercent
OBJECT-TYPE
The highest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.11INTEGER (5..20)read-writecurrent
tlpUpsConfigBypassLowerLimitVoltage
OBJECT-TYPE
The lowest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.12Unsigned32read-writecurrent
tlpUpsConfigBypassUpperLimitVoltage
OBJECT-TYPE
The highest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.13Unsigned32read-writecurrent
tlpUpsConfigColdStart
OBJECT-TYPE
This option enables or disables the ability to turn the ups on without AC supplied. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.14INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigEconomicMode
OBJECT-TYPE
The configurable economic mode options for the ups. The online(0) mode is the default configuration of most upss, which is synonymous as having the economic mode disabled. The economy(1) mode is the typical configuration to run in economy mode, which is synonymous as having the economic mode enabled. Constant50Hz(2) is a power strategy, which fixes the output frequency at 50Hz. Constant60Hz(3) is a power strategy, which fixes the output frequency at 60Hz. ConstantAuto(4) regulates the output frequency at nominal input frequency. AutoAdaptive(5) mode will cause the ups to automatically switch between online(0), maximum quality, and economy(1), maximum efficiency, to improve efficiency during stable utility periods and improve output regulation during unstable utility periods. Not all values are supported by all upss. Most upss, if supportive of economic mode, only supports online(0) and economy(1). If the ups does not support economic mode, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.15INTEGER {online(0), economy(1), constant50Hz(2), constant60Hz(3), constantAuto(4), autoAdaptive(5)}read-writecurrent
tlpUpsConfigFaultAction
OBJECT-TYPE
Determines the action to take if the output needs to be shut down due to a fault condition, limited by the type of fault incurred. When configured for bypass(0), the ups will go to bypass on a fault condition. When configured for standby(1), the ups will go to standby mode on a fault condition. Either configuration will be valid as long as AC input is within normal line voltage and frequency limits when the fault condition occurs. If the line is outside these limits, the ups will turn off. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.16INTEGER {bypass(0), standby(1)}read-writecurrent
tlpUpsConfigOffMode
OBJECT-TYPE
This option governs what mode the ups should go into when AC input is available, but the load is either off or not battery backed up. If this setting is configured for bypass(1), the intention is that any time the ups would normally go into standby mode, it would instead go into bypass mode. Note that this setting does not dictate the mode for fault conditions, which is governed by tlpUpsConfigFaultAction. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.17INTEGER {standby(0), bypass(1)}read-writecurrent
tlpUpsConfigLineSensitivity
OBJECT-TYPE
Adjusts the AC line voltage sensitivity setting. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.18INTEGER {normal(0), reduced(1), fullyReduced(2)}read-writecurrent
tlpUpsConfigLineQualifyTime
OBJECT-TYPE
The amount of time the ups monitors line power quality for stability before ac power is restored. If there is an attempt to set this variable to a value that is not supported, the request will be rejected and the agent will respond with an appropriate error message.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.19Unsigned32read-writecurrent
tlpUpsConfigACPowerSenseType
OBJECT-TYPE
This option enables configuration of ups AC power sensing to maximize ups operation for standard line power AC and generator power applications. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.1.1.20INTEGER {generator(1), ups(2)}read-writecurrent
tlpUpsConfigAutoRestartTable
OBJECT-TYPE
The configurable automatic restart options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
1.3.6.1.4.1.850.1.1.3.1.5.2not-accessiblecurrent
tlpUpsConfigAutoRestartEntry
OBJECT-TYPE
An entry containing configurable automatic restart options for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.5.2.1not-accessiblecurrent
tlpUpsConfigAutoRestartInverterShutdown
OBJECT-TYPE
If enabled(1) and the ups is turned off from invert mode (via user interaction), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
1.3.6.1.4.1.850.1.1.3.1.5.2.1.1INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigAutoRestartDelayedWakeup
OBJECT-TYPE
If enabled(1) and power fails during a DelayBeforeStartup and line remains invalid after the timeout expires, the ups will be set to turn back on automatically. If disabled(0), the ups will turn back on and go to standby mode instead.
1.3.6.1.4.1.850.1.1.3.1.5.2.1.2INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigAutoRestartLowVoltageCutoff
OBJECT-TYPE
If enabled(1) and the ups is turned off from invert mode (via low voltage cutoff), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
1.3.6.1.4.1.850.1.1.3.1.5.2.1.3INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigAutoRestartOverLoad
OBJECT-TYPE
If enabled(1) and the ups is turned off from invert mode (via overload), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
1.3.6.1.4.1.850.1.1.3.1.5.2.1.4INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigAutoRestartOverTemperature
OBJECT-TYPE
If enabled(1) and the ups is turned off from invert mode (via over temperature), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.
1.3.6.1.4.1.850.1.1.3.1.5.2.1.5INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpUpsConfigThresholdTable
OBJECT-TYPE
The configurable threshold options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
1.3.6.1.4.1.850.1.1.3.1.5.3not-accessiblecurrent
tlpUpsConfigThresholdEntry
OBJECT-TYPE
An entry containing configurable threshold options for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.5.3.1not-accessiblecurrent
tlpUpsConfigBatteryAgeThreshold
OBJECT-TYPE
The number of months for a battery to be in service. The battery age alarm, tlpUpsAlarmBatteryAgeAboveThreshold, is triggered when the current date exceeds tlpUpsBatteryPackIdentInstallDate by tlpUpsConfigBatteryAgeThreshold months.
1.3.6.1.4.1.850.1.1.3.1.5.3.1.1Unsigned32read-writecurrent
tlpUpsConfigLowBatteryThreshold
OBJECT-TYPE
This value denotes the percentage of battery capacity remaining warning level. The low battery alarm, tlpUpsAlarmLowBattery, is triggered when tlpUpsEstimatedChargeRemaining drops below this value.
1.3.6.1.4.1.850.1.1.3.1.5.3.1.2INTEGER (5..95)read-writecurrent
tlpUpsConfigLowBatteryTime
OBJECT-TYPE
The value in seconds of tlpUpsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.
1.3.6.1.4.1.850.1.1.3.1.5.3.1.3Unsigned32read-writecurrent
tlpUpsConfigOverLoadThreshold
OBJECT-TYPE
This value denotes the percentage of load at which the overload condition occurs. The overload alarm, tlpUpsAlarmOutputOverload, is triggered when the percentage of output load exceeds this value.
1.3.6.1.4.1.850.1.1.3.1.5.3.1.4INTEGER (5..105)read-writecurrent
tlpUpsConfigVoltageTable
OBJECT-TYPE
The voltage configuration details for each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
1.3.6.1.4.1.850.1.1.3.1.5.4not-accessiblecurrent
tlpUpsConfigVoltageEntry
OBJECT-TYPE
An entry containing voltage configuration options for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.5.4.1not-accessiblecurrent
tlpUpsConfigHighVoltageTransfer
OBJECT-TYPE
The maximum line voltage allowed on the input source before the unit disconnects the AC input connection.
1.3.6.1.4.1.850.1.1.3.1.5.4.1.1Unsigned32read-writecurrent
tlpUpsConfigHighVoltageResetTolerance
OBJECT-TYPE
If an input connection is disconnected due to over-voltage, the line voltage on the input source has to fall below tlpUpsConfigHighVoltageTransfer less tlpUpsConfigHighVoltageTransferResetTolerance ` before the unit reconnects the AC input to input source.
1.3.6.1.4.1.850.1.1.3.1.5.4.1.2Unsigned32read-writecurrent
tlpUpsConfigHighVoltageReset
OBJECT-TYPE
If an input connection is disconnected due to over-voltage, the line voltage on the input source has to fall below tlpUpsConfigHighVoltageReset before the unit reconnects the AC input to input source.
1.3.6.1.4.1.850.1.1.3.1.5.4.1.3Unsigned32read-writecurrent
tlpUpsConfigLowVoltageTransfer
OBJECT-TYPE
The minimum line voltage allowed before the unit disconnects the AC input connection.
1.3.6.1.4.1.850.1.1.3.1.5.4.1.4Unsigned32read-writecurrent
tlpUpsConfigLowVoltageResetTolerance
OBJECT-TYPE
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above tlpUpsConfigLowVoltageTransfer plus tlpUpsConfigLowVoltageTransferResetTolerance before the unit reonnect the AC input to input source.
1.3.6.1.4.1.850.1.1.3.1.5.4.1.5Unsigned32read-writecurrent
tlpUpsConfigLowVoltageReset
OBJECT-TYPE
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above tlpUpsConfigLowVoltageReset before the unit reonnect the AC input to input source.
1.3.6.1.4.1.850.1.1.3.1.5.4.1.6Unsigned32read-writecurrent
tlpUpsConfigContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.1.5.5
tlpUpsConfigContactTable
OBJECT-TYPE
The configuration options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
1.3.6.1.4.1.850.1.1.3.1.5.5.1not-accessiblecurrent
tlpUpsConfigContactEntry
OBJECT-TYPE
An entry containing contact configuration options for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.5.5.1.1not-accessiblecurrent
tlpUpsConfigOutputContactBackupTimer
OBJECT-TYPE
This is the amount of runtime the UPS supports in battery mode before sending a configured output contact notification. Output contacts are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.5.1.1.1INTEGERread-writecurrent
tlpUpsConfigInputContactTable
OBJECT-TYPE
The input contact details of each ups in device table. the number of entries is given by tlpUpsIdentNumInputContacts. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
1.3.6.1.4.1.850.1.1.3.1.5.5.2not-accessiblecurrent
tlpUpsConfigInputContactEntry
OBJECT-TYPE
An entry containing input contact details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.5.5.2.1not-accessiblecurrent
tlpUpsConfigInputContactIndex
OBJECT-TYPE
The table row index for the ups input contact details.
1.3.6.1.4.1.850.1.1.3.1.5.5.2.1.1Unsigned32read-onlycurrent
tlpUpsConfigInputContactSetup
OBJECT-TYPE
Input contact configuration options. Input contacts are not supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.5.2.1.2INTEGER {userDefined(0), externalAlarm(1), externalBatteryAlarm(2), externalFanFailed(3), doorUnlock(4)}read-writecurrent
tlpUpsConfigOutputContactTable
OBJECT-TYPE
Output contact details of each ups in device table. The number of entries is given by tlpUpsIdentNumOutputContacts. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
1.3.6.1.4.1.850.1.1.3.1.5.5.3not-accessiblecurrent
tlpUpsConfigOutputContactEntry
OBJECT-TYPE
An entry containing output contact details for a particular ups.
1.3.6.1.4.1.850.1.1.3.1.5.5.3.1not-accessiblecurrent
tlpUpsConfigOutputContactIndex
OBJECT-TYPE
The table row index for the ups output contact details.
1.3.6.1.4.1.850.1.1.3.1.5.5.3.1.1Unsigned32read-onlycurrent
tlpUpsConfigOutputContactSetup
OBJECT-TYPE
Output contact configuration options. Output contacts are not supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.1.5.5.3.1.2INTEGER {disabled(0), onBattery(1), batteryLow(2), timer(3), alarm(4), fault(5), outputOff(6)}read-writecurrent
tlpPdu
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2
tlpPduIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.1
tlpPduIdentNumPdu
OBJECT-TYPE
The number of pdu devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.2.1.1Unsigned32read-onlycurrent
tlpPduIdentTable
OBJECT-TYPE
The identity details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
1.3.6.1.4.1.850.1.1.3.2.1.2not-accessiblecurrent
tlpPduIdentEntry
OBJECT-TYPE
An entry containing details for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1not-accessiblecurrent
tlpPduIdentNumInputs
OBJECT-TYPE
The number of input lines supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.1Unsigned32read-onlycurrent
tlpPduIdentNumOutputs
OBJECT-TYPE
The number of output lines supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.2Unsigned32read-onlycurrent
tlpPduIdentNumPhases
OBJECT-TYPE
The number of phases supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.3Unsigned32read-onlycurrent
tlpPduIdentNumOutlets
OBJECT-TYPE
The number of receptacles supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.4Unsigned32read-onlycurrent
tlpPduIdentNumOutletGroups
OBJECT-TYPE
The number of receptacle groups supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.5Unsigned32read-onlycurrent
tlpPduIdentNumCircuits
OBJECT-TYPE
The number of circuits supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.6Unsigned32read-onlycurrent
tlpPduIdentNumBreakers
OBJECT-TYPE
The number of monitored bank breakers supported by the pdu. If the pdu has breakers that are not monitored by the device, the value of zero(0) will be returned.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.7Unsigned32read-onlycurrent
tlpPduIdentNumHeatsinks
OBJECT-TYPE
The number of heatsink thermistors supported by the pdu.
1.3.6.1.4.1.850.1.1.3.2.1.2.1.8Unsigned32read-onlycurrent
tlpPduSupportsTable
OBJECT-TYPE
The supported details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
1.3.6.1.4.1.850.1.1.3.2.1.3not-accessiblecurrent
tlpPduSupportsEntry
OBJECT-TYPE
An entry containing supported details for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.1.3.1not-accessiblecurrent
tlpPduSupportsEnergywise
OBJECT-TYPE
Indicates whether the pdu supports Cisco EnergyWise.
1.3.6.1.4.1.850.1.1.3.2.1.3.1.1TruthValueread-onlycurrent
tlpPduSupportsRampShed
OBJECT-TYPE
Indicates whether the pdu supports ramping and shedding.
1.3.6.1.4.1.850.1.1.3.2.1.3.1.2TruthValueread-onlycurrent
tlpPduSupportsOutletGroup
OBJECT-TYPE
Indicates whether the pdu supports outlet groups.
1.3.6.1.4.1.850.1.1.3.2.1.3.1.3TruthValueread-onlycurrent
tlpPduSupportsOutletCurrentPower
OBJECT-TYPE
Indicates whether the pdu reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletCurrent and tlpPduOutletPower.
1.3.6.1.4.1.850.1.1.3.2.1.3.1.4TruthValueread-onlycurrent
tlpPduSupportsOutletVoltage
OBJECT-TYPE
Indicates whether the pdu reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletVoltage.
1.3.6.1.4.1.850.1.1.3.2.1.3.1.5TruthValueread-onlycurrent
tlpPduDisplayTable
OBJECT-TYPE
The display details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
1.3.6.1.4.1.850.1.1.3.2.1.4not-accessiblecurrent
tlpPduDisplayEntry
OBJECT-TYPE
An entry containing display details for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.1.4.1not-accessiblecurrent
tlpPduDisplayScheme
OBJECT-TYPE
Indicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1).
1.3.6.1.4.1.850.1.1.3.2.1.4.1.1INTEGER {schemeReverse(0), schemeNormal(1)}read-writecurrent
tlpPduDisplayOrientation
OBJECT-TYPE
Indicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0).
1.3.6.1.4.1.850.1.1.3.2.1.4.1.2INTEGER {displayNormal(0), displayReverse(1)}read-writecurrent
tlpPduDisplayAutoScroll
OBJECT-TYPE
Indicates whether the LED display automatically scrolls through displaying status values.
1.3.6.1.4.1.850.1.1.3.2.1.4.1.3INTEGER {scrollDisabled(0), scrollEnabled(1)}read-writecurrent
tlpPduDisplayIntensity
OBJECT-TYPE
Indicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted.
1.3.6.1.4.1.850.1.1.3.2.1.4.1.4INTEGER {intensity25(1), intensity50(2), intensity75(3), intensity100(4)}read-writecurrent
tlpPduDisplayUnits
OBJECT-TYPE
Indicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Fahrenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius.
1.3.6.1.4.1.850.1.1.3.2.1.4.1.5INTEGER {normal(0), metric(1)}read-writecurrent
tlpPduDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.2
tlpPduDeviceTable
OBJECT-TYPE
The device details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
1.3.6.1.4.1.850.1.1.3.2.2.1not-accessiblecurrent
tlpPduDeviceEntry
OBJECT-TYPE
An entry containing device details for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.2.1.1not-accessiblecurrent
tlpPduDeviceMainLoadState
OBJECT-TYPE
The current state of the main output of the device.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.1INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlpPduDeviceMainLoadControllable
OBJECT-TYPE
Indicates whether or not the main output is controllable, and whether the ups can be turned off and on.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.2TruthValueread-onlycurrent
tlpPduDeviceMainLoadCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.3INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpPduDevicePowerOnDelay
OBJECT-TYPE
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.4Integer32read-writecurrent
tlpPduDeviceTotalInputPowerRating
OBJECT-TYPE
The total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.5Integer32read-onlycurrent
tlpPduDeviceTemperatureC
OBJECT-TYPE
The ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.6Integer32read-onlycurrent
tlpPduDeviceTemperatureF
OBJECT-TYPE
The ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.7Integer32read-onlycurrent
tlpPduDevicePhaseImbalance
OBJECT-TYPE
The percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.8INTEGER (0..200)read-onlycurrent
tlpPduDeviceOutputPowerTotal
OBJECT-TYPE
The AC output total power for all circuits.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.9Unsigned32read-onlycurrent
tlpPduDeviceAggregatePowerFactor
OBJECT-TYPE
The aggregate power factor of all phases.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.10Unsigned32read-onlycurrent
tlpPduDeviceOutputCurrentPrecision
OBJECT-TYPE
Output current is reported by tlpPduOutputCurrent, tlpPduOutputCurrentMin and tlpPduOutputCurrentMax. These values are all reported in hundredths(0.01A), which accommodates all models; however, on any given device the actual precision may vary. All current values must be divided by 100 to obtain the actual value. For example, if tlpPduOutputCurrent reports 500, then the actual output current is 5.00. This tlpPduDeviceOutputCurrentPrecision defines the actual resolution of that value: wholeNumber(0) is 5, tenths(1) is 5.0 and hundredths(2) is 5.00.
1.3.6.1.4.1.850.1.1.3.2.2.1.1.11INTEGER {wholeNumber(0), tenths(1), hundredths(2)}read-onlycurrent
tlpPduDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3
tlpPduInput
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3.1
tlpPduInputTable
OBJECT-TYPE
The input details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of pdus managed by the agent as reported by tlpPduIdentNumPdus.
1.3.6.1.4.1.850.1.1.3.2.3.1.1not-accessiblecurrent
tlpPduInputEntry
OBJECT-TYPE
An entry containing information applicable to a particular pdu managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1not-accessiblecurrent
tlpPduInputNominalVoltage
OBJECT-TYPE
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.1Unsigned32read-onlycurrent
tlpPduInputNominalVoltagePhaseToPhase
OBJECT-TYPE
The nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.2Unsigned32read-onlycurrent
tlpPduInputNominalVoltagePhaseToNeutral
OBJECT-TYPE
The nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.3Unsigned32read-onlycurrent
tlpPduInputLowTransferVoltage
OBJECT-TYPE
The minimum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputLowTransferVoltageLowerBound and tlpPduInputLowTransferVoltageUpperBound respectively.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.4Unsigned32read-onlycurrent
tlpPduInputLowTransferVoltageLowerBound
OBJECT-TYPE
The lower boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.5Unsigned32read-onlycurrent
tlpPduInputLowTransferVoltageUpperBound
OBJECT-TYPE
The upper boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.6Unsigned32read-onlycurrent
tlpPduInputHighTransferVoltage
OBJECT-TYPE
The maximum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputHighTransferVoltageLowerBound and tlpPduInputHighTransferVoltageUpperBound respectively.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.7Unsigned32read-onlycurrent
tlpPduInputHighTransferVoltageLowerBound
OBJECT-TYPE
The lower boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.8Unsigned32read-onlycurrent
tlpPduInputHighTransferVoltageUpperBound
OBJECT-TYPE
The upper boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.9Unsigned32read-onlycurrent
tlpPduInputCurrentLimit
OBJECT-TYPE
The capacity of each phase conductor in the pdu limited by the AC input cord or any other potential limiting factors unique to a given unit.
1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.10Unsigned32read-onlycurrent
tlpPduInputPhaseTable
OBJECT-TYPE
The input phase details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumInputs and tlpPduIdentNumPhases per each device.
1.3.6.1.4.1.850.1.1.3.2.3.1.2not-accessiblecurrent
tlpPduInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1not-accessiblecurrent
tlpPduInputPhaseIndex
OBJECT-TYPE
The table row index for the pdu phase.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.1Unsigned32read-onlycurrent
tlpPduInputPhasePhaseType
OBJECT-TYPE
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.2INTEGER {phaseToNeutral(0), phaseToPhase(1)}read-onlycurrent
tlpPduInputPhaseFrequency
OBJECT-TYPE
The present input frequency for a given phase.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.3Unsigned32read-onlycurrent
tlpPduInputPhaseVoltage
OBJECT-TYPE
The magnitude of the present input voltage for a given phase.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.4Unsigned32read-onlycurrent
tlpPduInputPhaseVoltageMin
OBJECT-TYPE
The minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.5Unsigned32read-writecurrent
tlpPduInputPhaseVoltageMax
OBJECT-TYPE
The maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.6Unsigned32read-writecurrent
tlpPduInputPhaseCurrent
OBJECT-TYPE
The magnitude of the present input current for a given phase.
1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.7Unsigned32read-onlycurrent
tlpPduOutput
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3.2
tlpPduOutputTable
OBJECT-TYPE
The output details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutputs per each device.
1.3.6.1.4.1.850.1.1.3.2.3.2.1not-accessiblecurrent
tlpPduOutputEntry
OBJECT-TYPE
An entry containing output information applicable to a particular phase managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1not-accessiblecurrent
tlpPduOutputIndex
OBJECT-TYPE
The table row index for the pdu phase.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.1Unsigned32read-onlycurrent
tlpPduOutputPhase
OBJECT-TYPE
Indicates the phase associated with the output line.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.2INTEGER {phase1(1), phase2(2), phase3(3)}read-onlycurrent
tlpPduOutputPhaseType
OBJECT-TYPE
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.3INTEGER {phaseToNeutral(0), phaseToPhase(1)}read-onlycurrent
tlpPduOutputVoltage
OBJECT-TYPE
The magnitude of the present output voltage for a given output line.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.4Unsigned32read-onlycurrent
tlpPduOutputCurrent
OBJECT-TYPE
The output current, in hundredths of amps, for a given phase. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.5Unsigned32read-onlycurrent
tlpPduOutputCurrentMin
OBJECT-TYPE
The minimum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.6Unsigned32read-onlycurrent
tlpPduOutputCurrentMax
OBJECT-TYPE
The maximum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpPduDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.7Unsigned32read-onlycurrent
tlpPduOutputActivePower
OBJECT-TYPE
The output power for a given phase.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.8Unsigned32read-onlycurrent
tlpPduOutputPowerFactor
OBJECT-TYPE
The output power factor, in hundredths of a percent, for a given phase.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.9Unsigned32read-onlycurrent
tlpPduOutputSource
OBJECT-TYPE
The present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.10INTEGER {none(0), normal(1)}read-onlycurrent
tlpPduOutputFrequency
OBJECT-TYPE
The present output frequency. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.11Unsigned32read-onlycurrent
tlpPduOutputCalculatedPowerKVA
OBJECT-TYPE
The calculated amount of apparent power being used.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.12Unsigned32read-onlycurrent
tlpPduOutputCalculatedPowerKW
OBJECT-TYPE
The calculated amount of active power being used.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.13Unsigned32read-onlycurrent
tlpPduOutputCalculated24hrEnergy
OBJECT-TYPE
Estimated 24 hour power consumption using present value of tlpPduOutputCalculatedPowerKW.
1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.14Unsigned32read-onlycurrent
tlpPduOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3.3
tlpPduOutletTable
OBJECT-TYPE
The receptacle status details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutlets per each device.
1.3.6.1.4.1.850.1.1.3.2.3.3.1not-accessiblecurrent
tlpPduOutletEntry
OBJECT-TYPE
An entry containing information applicable to a particular outlet managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1not-accessiblecurrent
tlpPduOutletIndex
OBJECT-TYPE
The table row index for the pdu outlet.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.1Unsigned32read-onlycurrent
tlpPduOutletName
OBJECT-TYPE
A user-definable string identifying the name of the outlet.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.2DisplayStringread-writecurrent
tlpPduOutletDescription
OBJECT-TYPE
A user-definable string identifying the device(s) connected to the given outlet.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.3DisplayStringread-writecurrent
tlpPduOutletState
OBJECT-TYPE
The current state of the outlet.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.4INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlpPduOutletControllable
OBJECT-TYPE
Denotes whether this outlet is controllable.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.5TruthValueread-onlycurrent
tlpPduOutletCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.6INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpPduOutletVoltage
OBJECT-TYPE
The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpPduSupportsOutletVoltage.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.7Unsigned32read-onlycurrent
tlpPduOutletCurrent
OBJECT-TYPE
The present output current, in hundredths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpPduSupportsCurrentPower.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.8Unsigned32read-onlycurrent
tlpPduOutletPower
OBJECT-TYPE
The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpPduSupportsCurrentPower.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.9Unsigned32read-onlycurrent
tlpPduOutletRampAction
OBJECT-TYPE
The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.10INTEGER {remainOff(0), turnOnAfterDelay(1)}read-writecurrent
tlpPduOutletRampDelay
OBJECT-TYPE
The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.11Integer32read-writecurrent
tlpPduOutletShedAction
OBJECT-TYPE
The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.12INTEGER {remainOn(0), turnOffAfterDelay(1)}read-writecurrent
tlpPduOutletShedDelay
OBJECT-TYPE
The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.13Integer32read-writecurrent
tlpPduOutletGroup
OBJECT-TYPE
The tlpPduOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.14Integer32read-writecurrent
tlpPduOutletBank
OBJECT-TYPE
Indicates on which bank the given outlet is located.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.15Integer32read-onlycurrent
tlpPduOutletCircuit
OBJECT-TYPE
Indicates on which circuit the given outlet is wired.
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.16Integer32read-onlycurrent
tlpPduOutletPhase
OBJECT-TYPE
Indicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.17INTEGER {unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlycurrent
tlpPduOutletGroupTable
OBJECT-TYPE
The receptacle grouping details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutletGroups per each device.
1.3.6.1.4.1.850.1.1.3.2.3.3.2not-accessiblecurrent
tlpPduOutletGroupEntry
OBJECT-TYPE
An entry containing information applicable to a particular outlet group managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1not-accessiblecurrent
tlpPduOutletGroupIndex
OBJECT-TYPE
The table row index for the pdu outlet group.
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.1Unsigned32read-onlycurrent
tlpPduOutletGroupRowStatus
OBJECT-TYPE
Row status for the tlpPduOutletGroupTable
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.2RowStatusread-writecurrent
tlpPduOutletGroupName
OBJECT-TYPE
The name of this outlet group.
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.3DisplayStringread-writecurrent
tlpPduOutletGroupDescription
OBJECT-TYPE
A description for this outlet group.
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.4DisplayStringread-writecurrent
tlpPduOutletGroupState
OBJECT-TYPE
The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.5INTEGER {unknown(0), off(1), on(2), mixed(3)}read-onlycurrent
tlpPduOutletGroupCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.
1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.6INTEGER {turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpPduCircuit
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3.4
tlpPduCircuitTable
OBJECT-TYPE
A list of pdu circuit table entries. The number of entries is given by the value of tlpPduIdentNumCircuits.
1.3.6.1.4.1.850.1.1.3.2.3.4.1not-accessiblecurrent
tlpPduCircuitEntry
OBJECT-TYPE
An entry containing information applicable to a particular circuit managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1not-accessiblecurrent
tlpPduCircuitIndex
OBJECT-TYPE
The table row index for the pdu circuit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.1Unsigned32read-onlycurrent
tlpPduCircuitPhase
OBJECT-TYPE
Indicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.2INTEGER {unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlycurrent
tlpPduCircuitInputVoltage
OBJECT-TYPE
The input voltage for a circuit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.3Integer32read-onlycurrent
tlpPduCircuitTotalCurrent
OBJECT-TYPE
The total current, in hundredths of amps, for all receptacles in a given circuit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.4Integer32read-onlycurrent
tlpPduCircuitCurrentLimit
OBJECT-TYPE
The current capacity, in hundredths of amps, of a circuit in the system limited by the circuit breaker or wiring used in a given unit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.5Integer32read-onlycurrent
tlpPduCircuitCurrentMin
OBJECT-TYPE
The minimum total current, in hundredths of amps, for all receptacles in a given circuit since last reset.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.6Integer32read-onlycurrent
tlpPduCircuitCurrentMax
OBJECT-TYPE
The maximum total current, in hundredths of amps, for all receptacles in a given circuit since last reset.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.7Integer32read-onlycurrent
tlpPduCircuitTotalPower
OBJECT-TYPE
The total power for all receptacles in a given circuit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.8Integer32read-onlycurrent
tlpPduCircuitPowerFactor
OBJECT-TYPE
The power factor for all receptacles in a given circuit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.9INTEGER (0..200)read-onlycurrent
tlpPduCircuitUtilization
OBJECT-TYPE
The percentage of utilization of a given circuit. This is typically a calculation of tlpPduCircuitTotalCurrent / tlpPduCircuitCurrentLimit.
1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.10Unsigned32read-onlycurrent
tlpPduBreaker
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3.5
tlpPduBreakerTable
OBJECT-TYPE
A list of pdu bank breaker table entries. The number of entries is given by the value of tlpPduIdentNumBreakers.
1.3.6.1.4.1.850.1.1.3.2.3.5.1not-accessiblecurrent
tlpPduBreakerEntry
OBJECT-TYPE
An entry containing information applicable to a particular bank breaker managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.5.1.1not-accessiblecurrent
tlpPduBreakerIndex
OBJECT-TYPE
The table row index for the pdu bank breaker.
1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.1Unsigned32read-onlycurrent
tlpPduBreakerStatus
OBJECT-TYPE
Indicates whether the bank breaker is open(0), closed(1) or not installed(2).
1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.2INTEGER {open(0), closed(1), notInstalled(2)}read-onlycurrent
tlpPduHeatsink
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.3.6
tlpPduHeatsinkTable
OBJECT-TYPE
A list of pdu heatsink thermistor table entries. The number of entries is given by the value of tlpPduIdentNumHeatsinks.
1.3.6.1.4.1.850.1.1.3.2.3.6.1not-accessiblecurrent
tlpPduHeatsinkEntry
OBJECT-TYPE
An entry containing information applicable to a particular heatsink thermistor managed by this agent.
1.3.6.1.4.1.850.1.1.3.2.3.6.1.1not-accessiblecurrent
tlpPduHeatsinkIndex
OBJECT-TYPE
The table row index for the pdu heatsink thermistor.
1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.1Unsigned32read-onlycurrent
tlpPduHeatsinkStatus
OBJECT-TYPE
Indicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected.
1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.2INTEGER {notAvailable(0), available(1)}read-onlycurrent
tlpPduHeatsinkTemperatureC
OBJECT-TYPE
The temperature at the heatsink thermistor in tenths degrees Celsius. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.3Integer32read-onlycurrent
tlpPduHeatsinkTemperatureF
OBJECT-TYPE
The temperature at the heatsink thermistor in tenths degrees Fahrenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.4Integer32read-onlycurrent
tlpPduControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.4
tlpPduControlTable
OBJECT-TYPE
The actionable controls for each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
1.3.6.1.4.1.850.1.1.3.2.4.1not-accessiblecurrent
tlpPduControlEntry
OBJECT-TYPE
An entry containing controls for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.4.1.1not-accessiblecurrent
tlpPduControlRamp
OBJECT-TYPE
Set to TRUE to initiate the pre-designated ramp sequence on the pdu.
1.3.6.1.4.1.850.1.1.3.2.4.1.1.1TruthValueread-writecurrent
tlpPduControlShed
OBJECT-TYPE
Set to TRUE to initiate the pre-designated shed sequence on the pdu.
1.3.6.1.4.1.850.1.1.3.2.4.1.1.2TruthValueread-writecurrent
tlpPduControlPduOn
OBJECT-TYPE
Set to TRUE to turn the pdu on.
1.3.6.1.4.1.850.1.1.3.2.4.1.1.3TruthValueread-writecurrent
tlpPduControlPduOff
OBJECT-TYPE
Set to TRUE to turn the pdu off.
1.3.6.1.4.1.850.1.1.3.2.4.1.1.4TruthValueread-writecurrent
tlpPduControlPduReboot
OBJECT-TYPE
Set to TRUE to reboot the pdu.
1.3.6.1.4.1.850.1.1.3.2.4.1.1.5TruthValueread-writecurrent
tlpPduConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.2.5
tlpPduConfigTable
OBJECT-TYPE
The configuration options of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. Not all options are available on all pdus.
1.3.6.1.4.1.850.1.1.3.2.5.1not-accessiblecurrent
tlpPduConfigEntry
OBJECT-TYPE
An entry containing configuration options for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.5.1.1not-accessiblecurrent
tlpPduConfigInputVoltage
OBJECT-TYPE
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
1.3.6.1.4.1.850.1.1.3.2.5.1.1.1Unsigned32read-writecurrent
tlpPduConfigPhaseThresholdTable
OBJECT-TYPE
The configuration options of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. Not all options are available on all pdus.
1.3.6.1.4.1.850.1.1.3.2.5.2not-accessiblecurrent
tlpPduConfigPhaseThresholdEntry
OBJECT-TYPE
An entry containing threshold configuration options for a particular pdu.
1.3.6.1.4.1.850.1.1.3.2.5.2.1not-accessiblecurrent
tlpPduPhaseIndex
OBJECT-TYPE
The table row index for the pdu phase.
1.3.6.1.4.1.850.1.1.3.2.5.2.1.1Unsigned32read-onlycurrent
tlpPduConfigOutputCurrentThresholdTolerance
OBJECT-TYPE
The threshold tolerance value used together with output current high/low threshold to evaluate output current high/low condition.
1.3.6.1.4.1.850.1.1.3.2.5.2.1.2Unsigned32read-writecurrent
tlpPduConfigOutputCurrentHighThreshold
OBJECT-TYPE
The value at which a output current high condition is declared.
1.3.6.1.4.1.850.1.1.3.2.5.2.1.3Unsigned32read-writecurrent
tlpPduConfigOutputCurrentLowThreshold
OBJECT-TYPE
The value at which a output current low condition is declared.
1.3.6.1.4.1.850.1.1.3.2.5.2.1.4Unsigned32read-writecurrent
tlpEnvirosense
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.3
tlpEnvIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.3.1
tlpEnvIdentNumEnvirosense
OBJECT-TYPE
The number of envirosense devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.3.1.1Unsigned32read-onlycurrent
tlpEnvIdentTable
OBJECT-TYPE
The identity details of each envirosense in device table. This is a sparse dependent table, and will contain some subset of devices that are envirosenses.
1.3.6.1.4.1.850.1.1.3.3.1.2not-accessiblecurrent
tlpEnvIdentEntry
OBJECT-TYPE
An entry containing details for a particular envirosense.
1.3.6.1.4.1.850.1.1.3.3.1.2.1not-accessiblecurrent
tlpEnvIdentTempSupported
OBJECT-TYPE
Indicates whether or not temperature is supported.
1.3.6.1.4.1.850.1.1.3.3.1.2.1.1TruthValueread-onlycurrent
tlpEnvIdentHumiditySupported
OBJECT-TYPE
Indicates whether or not temperature is supported.
1.3.6.1.4.1.850.1.1.3.3.1.2.1.2TruthValueread-onlycurrent
tlpEnvNumInputContacts
OBJECT-TYPE
The number of input contacts supported by the envirosense.
1.3.6.1.4.1.850.1.1.3.3.1.2.1.3Unsigned32read-onlycurrent
tlpEnvNumOutputContacts
OBJECT-TYPE
The number of output contacts supported by the envirosense.
1.3.6.1.4.1.850.1.1.3.3.1.2.1.4Unsigned32read-onlycurrent
tlpEnvDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.3.3
tlpEnvTemperatureTable
OBJECT-TYPE
The temperature details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
1.3.6.1.4.1.850.1.1.3.3.3.1not-accessiblecurrent
tlpEnvTemperatureEntry
OBJECT-TYPE
An entry containing temperature details for a particular envirosense.
1.3.6.1.4.1.850.1.1.3.3.3.1.1not-accessiblecurrent
tlpEnvTemperatureC
OBJECT-TYPE
The ambient temperature.
1.3.6.1.4.1.850.1.1.3.3.3.1.1.1Integer32read-onlycurrent
tlpEnvTemperatureF
OBJECT-TYPE
The ambient temperature.
1.3.6.1.4.1.850.1.1.3.3.3.1.1.2Integer32read-onlycurrent
tlpEnvTemperatureInAlarm
OBJECT-TYPE
Indicates whether or not temperature is in alarm.
1.3.6.1.4.1.850.1.1.3.3.3.1.1.3TruthValueread-onlycurrent
tlpEnvHumidityTable
OBJECT-TYPE
The humidity details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
1.3.6.1.4.1.850.1.1.3.3.3.2not-accessiblecurrent
tlpEnvHumidityEntry
OBJECT-TYPE
An entry containing humidity details for a particular envirosense.
1.3.6.1.4.1.850.1.1.3.3.3.2.1not-accessiblecurrent
tlpEnvHumidityHumidity
OBJECT-TYPE
The ambient humidity.
1.3.6.1.4.1.850.1.1.3.3.3.2.1.1INTEGER (0..100)read-onlycurrent
tlpEnvHumidityInAlarm
OBJECT-TYPE
Indicates whether or not humidity is in alarm.
1.3.6.1.4.1.850.1.1.3.3.3.2.1.2TruthValueread-onlycurrent
tlpEnvInputContactTable
OBJECT-TYPE
The input contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
1.3.6.1.4.1.850.1.1.3.3.3.3not-accessiblecurrent
tlpEnvInputContactEntry
OBJECT-TYPE
An entry containing input contact details for a particular envirosense.
1.3.6.1.4.1.850.1.1.3.3.3.3.1not-accessiblecurrent
tlpEnvInputContactIndex
OBJECT-TYPE
The table row index for the envirosense input contact details.
1.3.6.1.4.1.850.1.1.3.3.3.3.1.1Unsigned32read-onlycurrent
tlpEnvInputContactName
OBJECT-TYPE
The name or description of the contact.
1.3.6.1.4.1.850.1.1.3.3.3.3.1.2DisplayStringread-writecurrent
tlpEnvInputContactNormalState
OBJECT-TYPE
The normal operating position of the contact.
1.3.6.1.4.1.850.1.1.3.3.3.3.1.3INTEGER {open(0), closed(1)}read-writecurrent
tlpEnvInputContactCurrentState
OBJECT-TYPE
The current state of the contact.
1.3.6.1.4.1.850.1.1.3.3.3.3.1.4INTEGER {open(0), closed(1)}read-onlycurrent
tlpEnvInputContactInAlarm
OBJECT-TYPE
Indicates whether or not the contact is in alarm.
1.3.6.1.4.1.850.1.1.3.3.3.3.1.5TruthValueread-onlycurrent
tlpEnvOutputContactTable
OBJECT-TYPE
The output contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
1.3.6.1.4.1.850.1.1.3.3.3.4not-accessiblecurrent
tlpEnvOutputContactEntry
OBJECT-TYPE
An entry containing output contact details for a particular envirosense.
1.3.6.1.4.1.850.1.1.3.3.3.4.1not-accessiblecurrent
tlpEnvOutputContactIndex
OBJECT-TYPE
The table row index for the envirosense output contact details.
1.3.6.1.4.1.850.1.1.3.3.3.4.1.1Unsigned32read-onlycurrent
tlpEnvOutputContactName
OBJECT-TYPE
The name or description of the contact.
1.3.6.1.4.1.850.1.1.3.3.3.4.1.2DisplayStringread-writecurrent
tlpEnvOutputContactNormalState
OBJECT-TYPE
The normal operating position of the contact.
1.3.6.1.4.1.850.1.1.3.3.3.4.1.3INTEGER {open(0), closed(1)}read-writecurrent
tlpEnvOutputContactCurrentState
OBJECT-TYPE
The current state of the contact.
1.3.6.1.4.1.850.1.1.3.3.3.4.1.4INTEGER {open(0), closed(1)}read-writecurrent
tlpEnvOutputContactInAlarm
OBJECT-TYPE
Indicates whether or not the contact is in alarm.
1.3.6.1.4.1.850.1.1.3.3.3.4.1.5TruthValueread-onlycurrent
tlpEnvConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.3.5
tlpEnvConfigTable
OBJECT-TYPE
The configuration options of each envirosense in device table. This is a sparse dependent table, and will contain some subset of devices that are envirosenses. Not all options are available on all envirosenses.
1.3.6.1.4.1.850.1.1.3.3.5.1not-accessiblecurrent
tlpEnvConfigEntry
OBJECT-TYPE
An entry containing configuration options for a particular envirosenses.
1.3.6.1.4.1.850.1.1.3.3.5.1.1not-accessiblecurrent
tlpEnvTemperatureLowLimit
OBJECT-TYPE
The lower alarm limit for ambient temperature.
1.3.6.1.4.1.850.1.1.3.3.5.1.1.1Integer32read-writecurrent
tlpEnvTemperatureHighLimit
OBJECT-TYPE
The upper alarm limit for ambient temperature.
1.3.6.1.4.1.850.1.1.3.3.5.1.1.2Integer32read-writecurrent
tlpEnvHumidityLowLimit
OBJECT-TYPE
The lower alarm limit for ambient humidity.
1.3.6.1.4.1.850.1.1.3.3.5.1.1.3INTEGER (0..100)read-writecurrent
tlpEnvHumidityHighLimit
OBJECT-TYPE
The upper alarm limit for ambient humidity.
1.3.6.1.4.1.850.1.1.3.3.5.1.1.4INTEGER (0..100)read-writecurrent
tlpAts
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4
tlpAtsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.1
tlpAtsIdentNumAts
OBJECT-TYPE
The number of ats devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.4.1.1Unsigned32read-onlycurrent
tlpAtsIdentTable
OBJECT-TYPE
The identity details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
1.3.6.1.4.1.850.1.1.3.4.1.2not-accessiblecurrent
tlpAtsIdentEntry
OBJECT-TYPE
An entry containing details for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1not-accessiblecurrent
tlpAtsIdentNumInputs
OBJECT-TYPE
The number of inputs supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.1Unsigned32read-onlycurrent
tlpAtsIdentNumOutputs
OBJECT-TYPE
The number of outputs supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.2Unsigned32read-onlycurrent
tlpAtsIdentNumPhases
OBJECT-TYPE
The number of phases per input supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.3Unsigned32read-onlycurrent
tlpAtsIdentNumOutlets
OBJECT-TYPE
The number of receptacles supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.4Unsigned32read-onlycurrent
tlpAtsIdentNumOutletGroups
OBJECT-TYPE
The number of receptacle groups supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.5Unsigned32read-onlycurrent
tlpAtsIdentNumCircuits
OBJECT-TYPE
The number of circuits supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.6Unsigned32read-onlycurrent
tlpAtsIdentNumBreakers
OBJECT-TYPE
The number of monitored bank breakers supported by the ats. If the ats has breakers that are not monitored by the device, the value of zero(0) will be returned.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.7Unsigned32read-onlycurrent
tlpAtsIdentNumHeatsinks
OBJECT-TYPE
The number of heatsink thermistors supported by the ats.
1.3.6.1.4.1.850.1.1.3.4.1.2.1.8Unsigned32read-onlycurrent
tlpAtsSupportsTable
OBJECT-TYPE
The supported details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
1.3.6.1.4.1.850.1.1.3.4.1.3not-accessiblecurrent
tlpAtsSupportsEntry
OBJECT-TYPE
An entry containing supported details for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.1.3.1not-accessiblecurrent
tlpAtsSupportsEnergywise
OBJECT-TYPE
Indicates whether the ats supports Cisco EnergyWise.
1.3.6.1.4.1.850.1.1.3.4.1.3.1.1TruthValueread-onlycurrent
tlpAtsSupportsRampShed
OBJECT-TYPE
Indicates whether the ats supports ramping and shedding.
1.3.6.1.4.1.850.1.1.3.4.1.3.1.2TruthValueread-onlycurrent
tlpAtsSupportsOutletGroup
OBJECT-TYPE
Indicates whether the ats supports outlet groups.
1.3.6.1.4.1.850.1.1.3.4.1.3.1.3TruthValueread-onlycurrent
tlpAtsSupportsOutletCurrentPower
OBJECT-TYPE
Indicates whether the ats reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletCurrent and tlpAtsOutletPower.
1.3.6.1.4.1.850.1.1.3.4.1.3.1.4TruthValueread-onlycurrent
tlpAtsSupportsOutletVoltage
OBJECT-TYPE
Indicates whether the ats reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletVoltage.
1.3.6.1.4.1.850.1.1.3.4.1.3.1.5TruthValueread-onlycurrent
tlpAtsDisplayTable
OBJECT-TYPE
The display details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
1.3.6.1.4.1.850.1.1.3.4.1.4not-accessiblecurrent
tlpAtsDisplayEntry
OBJECT-TYPE
An entry containing display details for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.1.4.1not-accessiblecurrent
tlpAtsDisplayScheme
OBJECT-TYPE
Indicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1).
1.3.6.1.4.1.850.1.1.3.4.1.4.1.1INTEGER {schemeReverse(0), schemeNormal(1)}read-writecurrent
tlpAtsDisplayOrientation
OBJECT-TYPE
Indicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0).
1.3.6.1.4.1.850.1.1.3.4.1.4.1.2INTEGER {displayNormal(0), displayReverse(1)}read-writecurrent
tlpAtsDisplayAutoScroll
OBJECT-TYPE
Indicates whether the LED display automatically scrolls through displaying status values.
1.3.6.1.4.1.850.1.1.3.4.1.4.1.3INTEGER {scrollDisabled(0), scrollEnabled(1)}read-writecurrent
tlpAtsDisplayIntensity
OBJECT-TYPE
Indicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted.
1.3.6.1.4.1.850.1.1.3.4.1.4.1.4INTEGER {intensity25(1), intensity50(2), intensity75(3), intensity100(4)}read-writecurrent
tlpAtsDisplayUnits
OBJECT-TYPE
Indicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Fahrenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius.
1.3.6.1.4.1.850.1.1.3.4.1.4.1.5INTEGER {normal(0), metric(1)}read-writecurrent
tlpAtsDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.2
tlpAtsDeviceTable
OBJECT-TYPE
The device details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
1.3.6.1.4.1.850.1.1.3.4.2.1not-accessiblecurrent
tlpAtsDeviceEntry
OBJECT-TYPE
An entry containing device details for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.2.1.1not-accessiblecurrent
tlpAtsDeviceMainLoadState
OBJECT-TYPE
The current state of the main output of the device.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.1INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlpAtsDeviceMainLoadControllable
OBJECT-TYPE
Indicates whether or not the main output is controllable, and whether the ups can be turned off and on.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.2TruthValueread-onlycurrent
tlpAtsDeviceMainLoadCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.3INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpAtsDevicePowerOnDelay
OBJECT-TYPE
The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.4Integer32read-writecurrent
tlpAtsDeviceTotalInputPowerRating
OBJECT-TYPE
The total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.5Integer32read-onlycurrent
tlpAtsDeviceTemperatureC
OBJECT-TYPE
The ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.6Integer32read-onlycurrent
tlpAtsDeviceTemperatureF
OBJECT-TYPE
The ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.7Integer32read-onlycurrent
tlpAtsDevicePhaseImbalance
OBJECT-TYPE
The percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.8INTEGER (0..200)read-onlycurrent
tlpAtsDeviceOutputPowerTotal
OBJECT-TYPE
The AC output total power for all circuits.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.9Unsigned32read-onlycurrent
tlpAtsDeviceAggregatePowerFactor
OBJECT-TYPE
The aggregate power factor of all phases.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.10Unsigned32read-onlycurrent
tlpAtsDeviceOutputCurrentPrecision
OBJECT-TYPE
Output current is reported by tlpAtsOutputCurrent, tlpAtsOutputCurrentMin and tlpAtsOutputCurrentMax. These values are all reported in hundredths (0.01A), which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpAtsOutputCurrent reports 530 and tlpAtsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.11INTEGER {none(0), tenths(1), hundredths(2)}read-onlycurrent
tlpAtsDeviceGeneralFault
OBJECT-TYPE
Indicates whether or not the ats is in a system fault condition. When the ats is in such a fault condition, the condition can be cleared with tlpAtsControlResetGeneralFault.
1.3.6.1.4.1.850.1.1.3.4.2.1.1.12TruthValueread-onlycurrent
tlpAtsDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3
tlpAtsInput
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3.1
tlpAtsInputTable
OBJECT-TYPE
The input details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of atss managed by the agent as reported by tlpAtsIdentNumAts.
1.3.6.1.4.1.850.1.1.3.4.3.1.1not-accessiblecurrent
tlpAtsInputEntry
OBJECT-TYPE
An entry containing information applicable to a particular primary input phase managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1not-accessiblecurrent
tlpAtsInputNominalVoltage
OBJECT-TYPE
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.1Unsigned32read-onlycurrent
tlpAtsInputNominalVoltagePhaseToPhase
OBJECT-TYPE
The nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.2Unsigned32read-onlycurrent
tlpAtsInputNominalVoltagePhaseToNeutral
OBJECT-TYPE
The nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.3Unsigned32read-onlycurrent
tlpAtsInputBadTransferVoltage
OBJECT-TYPE
The minimum line voltage allowed before the unit disconnects the AC input connection.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.4Unsigned32read-onlycurrent
tlpAtsInputBadTransferVoltageLowerBound
OBJECT-TYPE
The lower boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.5Unsigned32read-onlycurrent
tlpAtsInputBadTransferVoltageUpperBound
OBJECT-TYPE
The upper boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.6Unsigned32read-onlycurrent
tlpAtsInputHighTransferVoltage
OBJECT-TYPE
The maximum line voltage allowed before the unit disconnects the AC input connection.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.7Unsigned32read-onlycurrent
tlpAtsInputHighTransferVoltageLowerBound
OBJECT-TYPE
The lower boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.8Unsigned32read-onlycurrent
tlpAtsInputHighTransferVoltageUpperBound
OBJECT-TYPE
The upper boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.9Unsigned32read-onlycurrent
tlpAtsInputFairVoltageThreshold
OBJECT-TYPE
The voltage level at which the device will transition between sources.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.10Unsigned32read-onlycurrent
tlpAtsInputBadVoltageThreshold
OBJECT-TYPE
The minimum line voltage allowed before the device disconnects the AC input connection.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.11Unsigned32read-onlycurrent
tlpAtsInputSourceAvailability
OBJECT-TYPE
The determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.12INTEGER {none(0), inputSourceA(1), inputSourceB(2), inputSourceAB(3)}read-onlycurrent
tlpAtsInputSourceInUse
OBJECT-TYPE
The determination as to which one of two AC input lines is in use. Not all devices support the reporting of which source is currently in use. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.13INTEGER {inputSourceA(0), inputSourceB(1)}read-onlycurrent
tlpAtsInputSourceTransitionCount
OBJECT-TYPE
The number of times the device transitions between primary and secondary sources. Most devices are limited to 65533 transitions, after which the value will not increment. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.14Unsigned32read-onlycurrent
tlpAtsInputCurrentLimit
OBJECT-TYPE
The capacity of each phase conductor in the ats limited by the AC input cord or any other potential limiting factors unique to a given unit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.15Unsigned32read-onlycurrent
tlpAtsInputPhaseTable
OBJECT-TYPE
The input phase details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumInputs and tlpAtsIdentNumPhases per each device.
1.3.6.1.4.1.850.1.1.3.4.3.1.2not-accessiblecurrent
tlpAtsInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular primary input phase managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1not-accessiblecurrent
tlpAtsInputLineIndex
OBJECT-TYPE
The table row index for the input line on the ats.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.1Unsigned32read-onlycurrent
tlpAtsInputPhaseIndex
OBJECT-TYPE
The table row index for the input phase for the input line.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.2Unsigned32read-onlycurrent
tlpAtsInputPhaseType
OBJECT-TYPE
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.3INTEGER {phaseToNeutral(0), phaseToPhase(1)}read-onlycurrent
tlpAtsInputPhaseFrequency
OBJECT-TYPE
The present input frequency for a given phase.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.4Unsigned32read-onlycurrent
tlpAtsInputPhaseVoltage
OBJECT-TYPE
The magnitude of the present input voltage for a given phase.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5Unsigned32read-onlycurrent
tlpAtsInputPhaseVoltageMin
OBJECT-TYPE
The minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.6Unsigned32read-writecurrent
tlpAtsInputPhaseVoltageMax
OBJECT-TYPE
The maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.7Unsigned32read-writecurrent
tlpAtsInputPhaseCurrent
OBJECT-TYPE
The magnitude of the present input current for a given phase.
1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.8Unsigned32read-onlycurrent
tlpAtsOutput
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3.2
tlpAtsOutputTable
OBJECT-TYPE
The output details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutputs per each device.
1.3.6.1.4.1.850.1.1.3.4.3.2.1not-accessiblecurrent
tlpAtsOutputEntry
OBJECT-TYPE
An entry containing output information applicable to a particular phase managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1not-accessiblecurrent
tlpAtsOutputIndex
OBJECT-TYPE
The table row index for the ats phase.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.1Unsigned32read-onlycurrent
tlpAtsOutputPhase
OBJECT-TYPE
Indicates the phase associated with the output line.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.2INTEGER {phase1(1), phase2(2), phase3(3)}read-onlycurrent
tlpAtsOutputPhaseType
OBJECT-TYPE
Denotes whether measurements are phase to neutral(0) or phase to phase(1).
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.3INTEGER {phaseToNeutral(0), phaseToPhase(1)}read-onlycurrent
tlpAtsOutputVoltage
OBJECT-TYPE
The magnitude of the present output voltage for a given output line.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.4Unsigned32read-onlycurrent
tlpAtsOutputCurrent
OBJECT-TYPE
The output current, in hundredths of amps, for a given phase. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5Unsigned32read-onlycurrent
tlpAtsOutputCurrentMin
OBJECT-TYPE
The minimum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.6Unsigned32read-onlycurrent
tlpAtsOutputCurrentMax
OBJECT-TYPE
The maximum current, in hundredths of amps, observed for a given phase since last reset. The actual precision of this value, whether a whole number, tenths or hundredths, is returned by tlpAtsDeviceOutputCurrentPrecision.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.7Unsigned32read-onlycurrent
tlpAtsOutputActivePower
OBJECT-TYPE
The output power for a given phase.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.8Unsigned32read-onlycurrent
tlpAtsOutputPowerFactor
OBJECT-TYPE
The output power factor, in hundredths of a percent, for a given phase.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.9Unsigned32read-onlycurrent
tlpAtsOutputSource
OBJECT-TYPE
The present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.10INTEGER {none(0), normal(1)}read-onlycurrent
tlpAtsOutputFrequency
OBJECT-TYPE
The present output frequency. If not supported, the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.11Unsigned32read-onlycurrent
tlpAtsOutputCalculatedPowerKVA
OBJECT-TYPE
The calculated amount of apparent power being used.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.12Unsigned32read-onlycurrent
tlpAtsOutputCalculatedPowerKW
OBJECT-TYPE
The calculated amount of active power being used.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.13Unsigned32read-onlycurrent
tlpAtsOutputCalculated24hrEnergy
OBJECT-TYPE
Estimated 24 hour power consumption using present value of tlpAtsOutputCalculatedPowerKW.
1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.14Unsigned32read-onlycurrent
tlpAtsOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3.3
tlpAtsOutletTable
OBJECT-TYPE
The receptacle status details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutlets per each device.
1.3.6.1.4.1.850.1.1.3.4.3.3.1not-accessiblecurrent
tlpAtsOutletEntry
OBJECT-TYPE
An entry containing information applicable to a particular outlet managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1not-accessiblecurrent
tlpAtsOutletIndex
OBJECT-TYPE
The table row index for the ats outlet.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.1Unsigned32read-onlycurrent
tlpAtsOutletName
OBJECT-TYPE
A user-definable string identifying the name of the outlet.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.2DisplayStringread-writecurrent
tlpAtsOutletDescription
OBJECT-TYPE
A user-definable string identifying the device(s) connected to the given outlet.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.3DisplayStringread-writecurrent
tlpAtsOutletState
OBJECT-TYPE
The current state of the outlet.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.4INTEGER {unknown(0), off(1), on(2)}read-onlycurrent
tlpAtsOutletControllable
OBJECT-TYPE
Denotes whether this outlet is controllable.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.5TruthValueread-onlycurrent
tlpAtsOutletCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.6INTEGER {idle(0), turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpAtsOutletVoltage
OBJECT-TYPE
The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpAtsSupportsOutletVoltage.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.7Unsigned32read-onlycurrent
tlpAtsOutletCurrent
OBJECT-TYPE
The present output current, in hundredths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpAtsSupportsCurrentPower.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.8Unsigned32read-onlycurrent
tlpAtsOutletPower
OBJECT-TYPE
The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpAtsSupportsCurrentPower.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.9Unsigned32read-onlycurrent
tlpAtsOutletRampAction
OBJECT-TYPE
The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.10INTEGER {remainOff(0), turnOnAfterDelay(1)}read-writecurrent
tlpAtsOutletRampDelay
OBJECT-TYPE
The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.11Integer32read-writecurrent
tlpAtsOutletShedAction
OBJECT-TYPE
The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.12INTEGER {remainOn(0), turnOffAfterDelay(1)}read-writecurrent
tlpAtsOutletShedDelay
OBJECT-TYPE
The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.13Integer32read-writecurrent
tlpAtsOutletGroup
OBJECT-TYPE
The tlpAtsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.14Integer32read-writecurrent
tlpAtsOutletBank
OBJECT-TYPE
Indicates on which bank the given outlet is located.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.15Integer32read-onlycurrent
tlpAtsOutletCircuit
OBJECT-TYPE
Indicates on which circuit the given outlet is wired.
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.16Integer32read-onlycurrent
tlpAtsOutletPhase
OBJECT-TYPE
Indicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.17INTEGER {unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlycurrent
tlpAtsOutletGroupTable
OBJECT-TYPE
The receptacle grouping details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutletGroups per each device.
1.3.6.1.4.1.850.1.1.3.4.3.3.2not-accessiblecurrent
tlpAtsOutletGroupEntry
OBJECT-TYPE
An entry containing information applicable to a particular outlet group managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1not-accessiblecurrent
tlpAtsOutletGroupIndex
OBJECT-TYPE
The table row index for the ats outlet group.
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.1Unsigned32read-onlycurrent
tlpAtsOutletGroupRowStatus
OBJECT-TYPE
Row status for the tlpAtsOutletGroupTable
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.2RowStatusread-writecurrent
tlpAtsOutletGroupName
OBJECT-TYPE
The name of this outlet group.
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.3DisplayStringread-writecurrent
tlpAtsOutletGroupDescription
OBJECT-TYPE
A description for this outlet group.
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.4DisplayStringread-writecurrent
tlpAtsOutletGroupState
OBJECT-TYPE
The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.5INTEGER {unknown(0), off(1), on(2), mixed(3)}read-onlycurrent
tlpAtsOutletGroupCommand
OBJECT-TYPE
Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.
1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.6INTEGER {turnOff(1), turnOn(2), cycle(3)}read-writecurrent
tlpAtsCircuit
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3.4
tlpAtsCircuitTable
OBJECT-TYPE
A list of ats circuit table entries. The number of entries is given by the value of tlpAtsIdentNumCircuits.
1.3.6.1.4.1.850.1.1.3.4.3.4.1not-accessiblecurrent
tlpAtsCircuitEntry
OBJECT-TYPE
An entry containing information applicable to a particular circuit managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1not-accessiblecurrent
tlpAtsCircuitIndex
OBJECT-TYPE
The table row index for the ats circuit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.1Unsigned32read-onlycurrent
tlpAtsCircuitPhase
OBJECT-TYPE
Indicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.2INTEGER {unknown(0), phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlycurrent
tlpAtsCircuitInputVoltage
OBJECT-TYPE
The input voltage for a circuit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.3Integer32read-onlycurrent
tlpAtsCircuitTotalCurrent
OBJECT-TYPE
The total current for all receptacles in a given circuit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.4Integer32read-onlycurrent
tlpAtsCircuitCurrentLimit
OBJECT-TYPE
The current capacity of a circuit in the system limited by the circuit breaker or wiring used in a given unit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.5Integer32read-onlycurrent
tlpAtsCircuitCurrentMin
OBJECT-TYPE
The minimum total current for all receptacles in a given circuit since last reset.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.6Integer32read-onlycurrent
tlpAtsCircuitCurrentMax
OBJECT-TYPE
The maximum total current for all receptacles in a given circuit since last reset.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.7Integer32read-onlycurrent
tlpAtsCircuitTotalPower
OBJECT-TYPE
The total power for all receptacles in a given circuit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.8Integer32read-onlycurrent
tlpAtsCircuitPowerFactor
OBJECT-TYPE
The power factor for all receptacles in a given circuit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.9INTEGER (0..200)read-onlycurrent
tlpAtsCircuitUtilization
OBJECT-TYPE
The percentage of utilization of a given circuit. This is typically a calculation of tlpAtsCircuitTotalCurrent / tlpAtsCircuitCurrentLimit.
1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.10Unsigned32read-onlycurrent
tlpAtsBreaker
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3.5
tlpAtsBreakerTable
OBJECT-TYPE
A list of ats bank breaker table entries. The number of entries is given by the value of tlpAtsIdentNumBreakers.
1.3.6.1.4.1.850.1.1.3.4.3.5.1not-accessiblecurrent
tlpAtsBreakerEntry
OBJECT-TYPE
An entry containing information applicable to a particular bank breaker managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.5.1.1not-accessiblecurrent
tlpAtsBreakerIndex
OBJECT-TYPE
The table row index for the ats bank breaker.
1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.1Unsigned32read-onlycurrent
tlpAtsBreakerStatus
OBJECT-TYPE
Indicates whether the bank breaker is open(0), closed(1) or not installed(2).
1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.2INTEGER {open(0), closed(1), notInstalled(2)}read-onlycurrent
tlpAtsHeatsink
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.3.6
tlpAtsHeatsinkTable
OBJECT-TYPE
A list of ats heatsink thermistor table entries. The number of entries is given by the value of tlpAtsIdentNumHeatsinks.
1.3.6.1.4.1.850.1.1.3.4.3.6.1not-accessiblecurrent
tlpAtsHeatsinkEntry
OBJECT-TYPE
An entry containing information applicable to a particular heatsink thermistor managed by this agent.
1.3.6.1.4.1.850.1.1.3.4.3.6.1.1not-accessiblecurrent
tlpAtsHeatsinkIndex
OBJECT-TYPE
The table row index for the ats heatsink thermistor.
1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.1Unsigned32read-onlycurrent
tlpAtsHeatsinkStatus
OBJECT-TYPE
Indicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected.
1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.2INTEGER {notAvailable(0), available(1)}read-onlycurrent
tlpAtsHeatsinkTemperatureC
OBJECT-TYPE
The temperature at the heatsink thermistor in tenths degrees Celsius. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.3Integer32read-onlycurrent
tlpAtsHeatsinkTemperatureF
OBJECT-TYPE
The temperature at the heatsink thermistor in tenths degrees Fahrenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.4Integer32read-onlycurrent
tlpAtsControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.4
tlpAtsControlTable
OBJECT-TYPE
The actionable controls for each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
1.3.6.1.4.1.850.1.1.3.4.4.1not-accessiblecurrent
tlpAtsControlEntry
OBJECT-TYPE
An entry containing controls for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.4.1.1not-accessiblecurrent
tlpAtsControlRamp
OBJECT-TYPE
Set to TRUE to initiate the pre-designated ramp sequence on the ats.
1.3.6.1.4.1.850.1.1.3.4.4.1.1.1TruthValueread-writecurrent
tlpAtsControlShed
OBJECT-TYPE
Set to TRUE to initiate the pre-designated shed sequence on the ats.
1.3.6.1.4.1.850.1.1.3.4.4.1.1.2TruthValueread-writecurrent
tlpAtsControlAtsOn
OBJECT-TYPE
Set to TRUE to turn the ats on.
1.3.6.1.4.1.850.1.1.3.4.4.1.1.3TruthValueread-writecurrent
tlpAtsControlAtsOff
OBJECT-TYPE
Set to TRUE to turn the ats off.
1.3.6.1.4.1.850.1.1.3.4.4.1.1.4TruthValueread-writecurrent
tlpAtsControlAtsReboot
OBJECT-TYPE
Set to TRUE to reboot the ats.
1.3.6.1.4.1.850.1.1.3.4.4.1.1.5TruthValueread-writecurrent
tlpAtsControlResetGeneralFault
OBJECT-TYPE
Set to TRUE to reset the general fault alarm indicated by tlpAtsDeviceGeneralFault.
1.3.6.1.4.1.850.1.1.3.4.4.1.1.6TruthValueread-writecurrent
tlpAtsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.4.5
tlpAtsConfigTable
OBJECT-TYPE
The configuration options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss.
1.3.6.1.4.1.850.1.1.3.4.5.1not-accessiblecurrent
tlpAtsConfigEntry
OBJECT-TYPE
An entry containing configuration options for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.5.1.1not-accessiblecurrent
tlpAtsConfigInputVoltage
OBJECT-TYPE
The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.
1.3.6.1.4.1.850.1.1.3.4.5.1.1.1Unsigned32read-writecurrent
tlpAtsConfigSourceSelect
OBJECT-TYPE
The determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(1) for devices with a single input source. Setting this value is supported only on selected models.
1.3.6.1.4.1.850.1.1.3.4.5.1.1.2INTEGER {inputSourceA(1), inputSourceB(2)}read-writecurrent
tlpAtsConfigSource1ReturnTime
OBJECT-TYPE
The nominal time to delay a transition to Source 1, if it is the preferred source.
1.3.6.1.4.1.850.1.1.3.4.5.1.1.3Unsigned32read-writecurrent
tlpAtsConfigSource2ReturnTime
OBJECT-TYPE
The nominal time to delay a transition to Source 2, if it is the preferred source.
1.3.6.1.4.1.850.1.1.3.4.5.1.1.4Unsigned32read-writecurrent
tlpAtsConfigAutoRampOnTransition
OBJECT-TYPE
When enabled(1), the ats should perform its preconfigured ramp sequence when the input source transfers from its designated secondary source to its designated primary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.1.1.5INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpAtsConfigAutoShedOnTransition
OBJECT-TYPE
When enabled(1), the ats should perform its preconfigured shed sequence when the input source transfers from its designated primary source to its designated secondary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.1.1.6INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpAtsConfigVoltageRangeOldTable
OBJECT-TYPE
The voltage range options in this table is intended to configure the operating voltages of an ats. This is a sparse dependent table, and will contain some subset of devices that are atss. All voltage points defined in this table are listed in a specific order from high to low. All voltage points must satisfy the conditions and ranges defined for each point. Any point violating any of the relative limits will be rejected. For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1% of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset (tlpAtsConfigSource2TransferReset) be set higher than tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet). *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound. The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All minimum and maximum limits for each voltage point are all exclusive unless indicated otherwise. This table in its entirety is obsolete and replaced by tlpAtsConfigVoltageRangeTable.
1.3.6.1.4.1.850.1.1.3.4.5.2not-accessibleobsolete
tlpAtsConfigVoltageRangeOldEntry
OBJECT-TYPE
An entry containing voltage range configuration options for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.5.2.1not-accessibleobsolete
tlpAtsConfigHighVoltageTransferOld
OBJECT-TYPE
The maximum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. This value may not be configurable on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.1Unsigned32read-writeobsolete
tlpAtsConfigHighVoltageResetOld
OBJECT-TYPE
If a unit is disconnected due to over-voltage, the line voltage has to fall below this value before the unit re-connects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransferOld. The minimum value allowed is dictated by the greater of tlpAtsConfigSource1TransferResetOld and tlpAtsConfigSource2TransferResetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.2Unsigned32read-writeobsolete
tlpAtsConfigSource1TransferResetOld
OBJECT-TYPE
If input source 1 voltage level is above this value, a unit connected to source 2 will transition to source 1 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The minimum value allowed is dictated by tlpAtsConfigSource1BrownoutSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.3Unsigned32read-writeobsolete
tlpAtsConfigSource1BrownoutSetOld
OBJECT-TYPE
This value dictates the voltage level below which source 1 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource1TransferResetOld. The minimum value allowed is dictated by tlpAtsConfigSource1TransferSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.4Unsigned32read-writeobsolete
tlpAtsConfigSource1TransferSetOld
OBJECT-TYPE
If input source 1 voltage level falls below this value, a unit connected to source 1 will transition to source 2 (if it is in fair condition as denoted by tlpAtsConfigSource2TransferSetOld). The maximum value allowed is dictated by tlpAtsConfigSource1BrownoutSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageResetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.5Unsigned32read-writeobsolete
tlpAtsConfigSource2TransferResetOld
OBJECT-TYPE
If input source 2 voltage level is above this value, a unit connected to source 1 will transition to source 2 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageResetOld. The minimum value allowed is dictated by tlpAtsConfigSource2BrownoutSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.6Unsigned32read-writeobsolete
tlpAtsConfigSource2BrownoutSetOld
OBJECT-TYPE
This value dictates the voltage level below which source 2 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource2TransferResetOld. The minimum value allowed is dictated by tlpAtsConfigSource2TransferSetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.7Unsigned32read-writeobsolete
tlpAtsConfigSource2TransferSetOld
OBJECT-TYPE
If input source 2 voltage level falls below this value, a unit connected to source 2 will transition to source 1 (if it is in fair condition as denoted by tlpAtsConfigSource1TransferSetOld). The maximum value allowed is dictated by tlpAtsConfigSource2BrownoutSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageResetOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.8Unsigned32read-writeobsolete
tlpAtsConfigLowVoltageResetOld
OBJECT-TYPE
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. The maximum value allowed is dictated by the lesser value of tlpAtsConfigSource1TransferSetOld and tlpAtsConfigSource2TransferSetOld. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransferOld. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.9Unsigned32read-writeobsolete
tlpAtsConfigLowVoltageTransferOld
OBJECT-TYPE
The minimum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigLowVoltageResetOld. The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.2.1.10Unsigned32read-writeobsolete
tlpAtsConfigVoltageRangeLimitsTable
OBJECT-TYPE
The voltage range table, as documented by tlpAtsConfigVoltageRangeTable requires that all changes adhere with stack order, from high transfer voltage down to low transfer voltage. In addition to stack order, certain voltage range values have limits defining the absolute minimum and absolute maximum for such values. Any voltage value violating any respective limit defined herein will be rejected.
1.3.6.1.4.1.850.1.1.3.4.5.3not-accessiblecurrent
tlpAtsConfigVoltageRangeLimitsEntry
OBJECT-TYPE
An entry containing voltage range limits configuration options for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.5.3.1not-accessiblecurrent
tlpAtsConfigSourceBrownoutSetMinimum
OBJECT-TYPE
This value dictates the absolute lower limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet, respectively, are also used when determining the lowest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.3.1.1Unsigned32read-writecurrent
tlpAtsConfigSourceBrownoutSetMaximum
OBJECT-TYPE
This value dictates the absolute upper limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferReset and tlpAtsConfigSource2TransferReset, respectively, are also used when determining the greatest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.3.1.2Unsigned32read-writecurrent
tlpAtsConfigSourceTransferSetMinimum
OBJECT-TYPE
This value dictates the absolute lower limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigLowVoltageReset is also used when determining the lowest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.3.1.3Unsigned32read-writecurrent
tlpAtsConfigSourceTransferSetMaximum
OBJECT-TYPE
This value dictates the absolute upper limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet, respectively, are also used when determining the greatest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.3.1.4Unsigned32read-writecurrent
tlpAtsConfigThresholdTable
OBJECT-TYPE
The configurable threshold options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss.
1.3.6.1.4.1.850.1.1.3.4.5.4not-accessiblecurrent
tlpAtsConfigThresholdEntry
OBJECT-TYPE
An entry containing configurable threshold options for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.5.4.1not-accessiblecurrent
tlpAtsConfigOutputCurrentThreshold
OBJECT-TYPE
The output current measurement at which an over current condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.4.1.1Unsigned32read-writecurrent
tlpAtsConfigOverTemperatureThreshold
OBJECT-TYPE
The system temperature at which an over temperature condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.4.1.2Unsigned32read-writecurrent
tlpAtsConfigOverVoltageThreshold
OBJECT-TYPE
The input voltage measurement at which an over voltage condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.4.1.3Unsigned32read-writecurrent
tlpAtsConfigOverLoadThreshold
OBJECT-TYPE
The system load at which an overload condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.4.1.4Unsigned32read-writecurrent
tlpAtsConfigVoltageRangeTable
OBJECT-TYPE
The voltage range options in this table is intended to configure the operating voltages of an ats. This is a sparse dependent table, and will contain some subset of devices that are atss. All voltage points defined in this table are listed in a specific order from high to low. All voltage points must satisfy the conditions and ranges defined for each point. Any point violating any of the relative limits will be rejected. For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1% of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset (tlpAtsConfigSource2TransferReset) be set higher than tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet). *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound. The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All minimum and maximum limits for each voltage point are all exclusive unless indicated otherwise.
1.3.6.1.4.1.850.1.1.3.4.5.5not-accessiblecurrent
tlpAtsConfigVoltageRangeEntry
OBJECT-TYPE
An entry containing voltage range configuration options for a particular ats.
1.3.6.1.4.1.850.1.1.3.4.5.5.1not-accessiblecurrent
tlpAtsConfigHighVoltageTransfer
OBJECT-TYPE
The maximum line voltage allowed on the input source before the unit disconnects the AC input connection. tlpAtsConfigHighVoltageTransfer is the same value for both input sources on some units. On such units, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageReset. This value may not be configurable on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.1Unsigned32read-writecurrent
tlpAtsConfigHighVoltageReset
OBJECT-TYPE
If an input connection is disconnected due to over-voltage, the line voltage on the input source has to fall below this value before the unit re-connects the AC input connection for the input source. tlpAtsConfigHighVoltageReset is the same value for both input sources on some units. On such units, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransfer. On units where this is the same value for both sources, the minimum value allowed is dictated by the greater of tlpAtsConfigTransferReset.1 and tlpAtsConfigTransferReset.2. On units where the value is distinct for each source, the minimum value allowed is dictated solely by this source's tlpAtsConfigTransferReset. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.2Unsigned32read-writecurrent
tlpAtsConfigTransferReset
OBJECT-TYPE
If input source voltage level is above this value, a unit connected to this other input source will transition to this input source (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by tlpAtsConfigBrownoutSet. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.3Unsigned32read-writecurrent
tlpAtsConfigBrownoutSet
OBJECT-TYPE
This value dictates the voltage level below which the input source goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigTransferReset. The minimum value allowed is dictated by tlpAtsConfigTransferSet. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.4Unsigned32read-writecurrent
tlpAtsConfigTransferSet
OBJECT-TYPE
If input source voltage level falls below this value, a unit connected to this input source will transition to other input source (if it is in fair condition as denoted by tlpAtsConfigTransferSet). The maximum value allowed is dictated by tlpAtsConfigBrownoutSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageReset. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.5Unsigned32read-writecurrent
tlpAtsConfigLowVoltageReset
OBJECT-TYPE
If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. tlpAtsConfigLowVoltageReset is the same value for both input sources. As such, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by the lesser value of tlpAtsConfigTransferSet.1 and tlpAtsConfigTransferSet.2. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransfer. If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.6Unsigned32read-writecurrent
tlpAtsConfigLowVoltageTransfer
OBJECT-TYPE
The minimum line voltage allowed before the unit disconnects the AC input connection. tlpAtsConfigLowVoltageTransfer is the same value for both input sources. As such, changing this value on one source will change the value on the other source. The maximum value allowed is dictated by tlpAtsConfigLowVoltageReset. The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.4.5.5.1.7Unsigned32read-writecurrent
tlpAtsConfigPhaseThresholdTable
OBJECT-TYPE
The configuration options of each Ats in device table. This is a sparse dependent table, and will contain some subset of devices that are Atss. Not all options are available on all Atss.
1.3.6.1.4.1.850.1.1.3.4.5.6not-accessiblecurrent
tlpAtsConfigPhaseThresholdEntry
OBJECT-TYPE
An entry containing threshold configuration options for a particular Ats.
1.3.6.1.4.1.850.1.1.3.4.5.6.1not-accessiblecurrent
tlpAtsPhaseIndex
OBJECT-TYPE
The table row index for the Ats phase.
1.3.6.1.4.1.850.1.1.3.4.5.6.1.1Unsigned32read-onlycurrent
tlpAtsConfigOutputCurrentThresholdTolerance
OBJECT-TYPE
The threshold tolerance value used together with output current high/low threshold to evaluate output current high/low condition.
1.3.6.1.4.1.850.1.1.3.4.5.6.1.2Unsigned32read-writecurrent
tlpAtsConfigOutputCurrentHighThreshold
OBJECT-TYPE
The value at which a output current high condition is declared.
1.3.6.1.4.1.850.1.1.3.4.5.6.1.3Unsigned32read-writecurrent
tlpAtsConfigOutputCurrentLowThreshold
OBJECT-TYPE
The value at which a output current low condition is declared.
1.3.6.1.4.1.850.1.1.3.4.5.6.1.4Unsigned32read-writecurrent
tlpCooling
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5
tlpCoolingIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.1
tlpCoolingIdentNumCooling
OBJECT-TYPE
The number of cooling devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.5.1.1Unsigned32read-onlycurrent
tlpCoolingDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.2
tlpCoolingDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.3
tlpCoolingTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.3.1
tlpCoolingTemperatureFahrenheitTable
OBJECT-TYPE
The temperature details for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.1.1not-accessiblecurrent
tlpCoolingTemperatureFahrenheitEntry
OBJECT-TYPE
An entry containing temperature details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1not-accessiblecurrent
tlpCoolingAmbientDegF
OBJECT-TYPE
The ambient temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.1Integer32read-onlycurrent
tlpCoolingSupplyAirDegF
OBJECT-TYPE
The temperature of the air entering the cooling unit in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.2Integer32read-onlycurrent
tlpCoolingReturnAirDegF
OBJECT-TYPE
The temperature of the air entering the cooling unit in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.3Integer32read-onlycurrent
tlpCoolingCondenserInletDegF
OBJECT-TYPE
The temperature of the air entering the condenser in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.4Integer32read-onlycurrent
tlpCoolingEvaporatorDegF
OBJECT-TYPE
The temperature of the evaporator surface in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.5Integer32read-onlycurrent
tlpCoolingSuctionDegF
OBJECT-TYPE
The temperature of the low pressure refrigerant line in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.6Integer32read-onlycurrent
tlpCoolingRemoteDegF
OBJECT-TYPE
The external remote temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.7Integer32read-onlycurrent
tlpCoolingCondenserOutletDegF
OBJECT-TYPE
The temperature of the air leaving the condenser in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.1.1.8Integer32read-onlycurrent
tlpCoolingTemperatureCelsiusTable
OBJECT-TYPE
The temperature details for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.1.2not-accessiblecurrent
tlpCoolingTemperatureCelsiusEntry
OBJECT-TYPE
An entry containing temperature details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1not-accessiblecurrent
tlpCoolingAmbientDegC
OBJECT-TYPE
The ambient temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.1Integer32read-onlycurrent
tlpCoolingSupplyAirDegC
OBJECT-TYPE
The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.2Integer32read-onlycurrent
tlpCoolingReturnAirDegC
OBJECT-TYPE
The temperature of the air entering the cooling unit in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.3Integer32read-onlycurrent
tlpCoolingCondenserInletDegC
OBJECT-TYPE
The temperature of the air entering the condenser in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.4Integer32read-onlycurrent
tlpCoolingEvaporatorDegC
OBJECT-TYPE
The temperature of the evaporator surface in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.5Integer32read-onlycurrent
tlpCoolingSuctionDegC
OBJECT-TYPE
The temperature of the low pressure refrigerant line in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.6Integer32read-onlycurrent
tlpCoolingRemoteDegC
OBJECT-TYPE
The external remote temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.7Integer32read-onlycurrent
tlpCoolingCondenserOutletDegC
OBJECT-TYPE
The temperature of the air leaving the condenser in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.1.2.1.8Integer32read-onlycurrent
tlpCoolingPressure
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.3.2
tlpCoolingPressureMpaTable
OBJECT-TYPE
The pressure detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.2.1not-accessiblecurrent
tlpCoolingPressureMpaEntry
OBJECT-TYPE
An entry containing pressure details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.2.1.1not-accessiblecurrent
tlpCoolingSuctionPressureMpa
OBJECT-TYPE
The pressure of the compressor discharge line in tenths of Mpa. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.2.1.1.1Unsigned32read-onlycurrent
tlpCoolingDischargePressureMpa
OBJECT-TYPE
The pressure of the compressor discharge line in tenths of Mpa. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.2.1.1.2Unsigned32read-onlycurrent
tlpCoolingPressurePsiTable
OBJECT-TYPE
The pressure detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.2.2not-accessiblecurrent
tlpCoolingPressurePsiEntry
OBJECT-TYPE
An entry containing pressure details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.2.2.1not-accessiblecurrent
tlpCoolingSuctionPressurePsi
OBJECT-TYPE
The pressure of the compressor discharge line in tenths of Psi. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.2.2.1.1Unsigned32read-onlycurrent
tlpCoolingDischargePressurePsi
OBJECT-TYPE
The pressure of the compressor discharge line in tenths of Psi. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.2.2.1.2Unsigned32read-onlycurrent
tlpCoolingCurrentTable
OBJECT-TYPE
The input current for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.3not-accessiblecurrent
tlpCoolingCurrentEntry
OBJECT-TYPE
An entry containing input current for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.3.1not-accessiblecurrent
tlpCoolingUnitCurrent
OBJECT-TYPE
The total current draw of the unit in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.3.1.1Unsigned32read-onlycurrent
tlpCoolingCompressorCurrent
OBJECT-TYPE
The compressor current draw of the unit in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.3.1.2Unsigned32read-onlycurrent
tlpCoolingEvaporatorFanCurrent
OBJECT-TYPE
The current draw of the evaporator fan in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.3.1.3Unsigned32read-onlycurrent
tlpCoolingCondenserFanCurrent
OBJECT-TYPE
The current draw of the condenser fan in tenths of Amps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.3.1.4Unsigned32read-onlycurrent
tlpCoolingDynamicTable
OBJECT-TYPE
The dynamic detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.4not-accessiblecurrent
tlpCoolingDynamicEntry
OBJECT-TYPE
An entry dynamic details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.4.1not-accessiblecurrent
tlpCoolingEvaporatorFanSpeed
OBJECT-TYPE
The current speed of the evaporator fan. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.4.1.1INTEGER {off(0), low(1), mediumLow(2), medium(3), mediumHigh(4), high(5), auto(6)}read-onlycurrent
tlpCoolingCondenserFanSpeed
OBJECT-TYPE
The current speed of the condenser fan. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.4.1.2INTEGER {off(0), low(1), mediumLow(2), medium(3), mediumHigh(4), high(5), auto(6)}read-onlycurrent
tlpCoolingCompressorFrequency
OBJECT-TYPE
The operating mechanical frequency(Hz) of the compressor. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.4.1.3Unsigned32read-onlycurrent
tlpCoolingEEVSteps
OBJECT-TYPE
The current EEV steps. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.4.1.4INTEGERread-onlycurrent
tlpCoolingRuntimeTable
OBJECT-TYPE
The runtime detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.5not-accessiblecurrent
tlpCoolingRuntimeEntry
OBJECT-TYPE
An entry containing runtime for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.5.1not-accessiblecurrent
tlpCoolingCompressorRunDays
OBJECT-TYPE
Total days the compressor has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.5.1.1Unsigned32read-onlycurrent
tlpCoolingCondensatePumpRunDays
OBJECT-TYPE
Total days the condensate pump has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.5.1.2Unsigned32read-onlycurrent
tlpCoolingAirFilterRunHours
OBJECT-TYPE
Total hours the air filter has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.5.1.3Unsigned32read-onlycurrent
tlpCoolingEvaporatorFanRunDays
OBJECT-TYPE
Total days the evaporator fan has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.5.1.4Unsigned32read-onlycurrent
tlpCoolingCondenserFanRunDays
OBJECT-TYPE
Total days the condenser fan has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.5.1.5Unsigned32read-onlycurrent
tlpCoolingAtomizerRunDays
OBJECT-TYPE
Total days the atomizer has been under operation. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.5.1.6Unsigned32read-onlycurrent
tlpCoolingStatusTable
OBJECT-TYPE
The status detail for each cooling device in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of cooling device managed by the agent as reported by tlpCoolingIdentNumCooling.
1.3.6.1.4.1.850.1.1.3.5.3.6not-accessiblecurrent
tlpCoolingStatusEntry
OBJECT-TYPE
An entry containing status for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.3.6.1not-accessiblecurrent
tlpCoolingOperatingMode
OBJECT-TYPE
The current operating mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.6.1.1INTEGER {off(0), idle(1), cooling(2), shuttingDown(3), dehumidifying(4), defrosting(5), notConnected(6)}read-onlycurrent
tlpCoolingCoolOutput
OBJECT-TYPE
The current cooling output of the cooling device in tenth of kilowatt. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.6.1.2Unsigned32read-onlycurrent
tlpCoolingAlarmStatus
OBJECT-TYPE
The current alarm status of the cooling device. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.6.1.3INTEGER {noAlarm(0), warning(1), critical(2)}read-onlycurrent
tlpCoolingCompressorStatus
OBJECT-TYPE
The current operating status of compressor. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.6.1.4INTEGER {off(0), on(1)}read-onlycurrent
tlpCoolingWaterStatus
OBJECT-TYPE
The current water status of cooling unit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.3.6.1.5INTEGER {notFull(0), full(1)}read-onlycurrent
tlpCoolingControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.4
tlpCoolingControlTable
OBJECT-TYPE
The actionable controls for each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device.
1.3.6.1.4.1.850.1.1.3.5.4.1not-accessiblecurrent
tlpCoolingControlEntry
OBJECT-TYPE
An entry containing controls for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.4.1.1not-accessiblecurrent
tlpCoolingOnOff
OBJECT-TYPE
Turn the unit on or off.
1.3.6.1.4.1.850.1.1.3.5.4.1.1.1INTEGER {turnOffUnit(0), turnOnUnit(1)}read-writecurrent
tlpCoolingConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.5.5
tlpCoolingConfigTable
OBJECT-TYPE
The configuration details for each each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device. Not all options are available on all cooling devices.
1.3.6.1.4.1.850.1.1.3.5.5.1not-accessiblecurrent
tlpCoolingConfigEntry
OBJECT-TYPE
An entry configuration details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.5.1.1not-accessiblecurrent
tlpCoolingAutoStart
OBJECT-TYPE
Specifies if the unit should start automatically on power up. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.1INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingFanSpeed
OBJECT-TYPE
Specifies the actual speed of the evaporator fan. Setting the fan speed to auto(6) will enable tlpCoolingAutoFanSpeed; however, on most units getting the fan speed will return the actual fan speed regardless whether auto fan speed is enabled or disabled. The value auto(6) is returned only on units that do not report the actual fan speed when auto fan speed is enabled. Not all values are supported on all cooling units. Invalid values will return an appropriate error when accessed. If not supported, this value will always return ERROR_NO_SUCH_NAME
1.3.6.1.4.1.850.1.1.3.5.5.1.1.2INTEGER {off(0), low(1), mediumLow(2), medium(3), mediumHigh(4), high(5), auto(6)}read-writecurrent
tlpCoolingControlType
OBJECT-TYPE
Specifies which temperature is used as a control point. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.3INTEGER {returnAirTemperature(0), remoteTemperature(1)}read-writecurrent
tlpCoolingDisplayUnits
OBJECT-TYPE
Specifies whether displays output values in Metric or English formats. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.4INTEGER {metric(0), english(1)}read-writecurrent
tlpCoolingBeepOnKey
OBJECT-TYPE
Specifies whether a beep is emitted when a key is pressed on the unit's display panel. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.5INTEGER {noBeep(0), beepOn(1)}read-writecurrent
tlpCoolingInputContactType
OBJECT-TYPE
The input contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.6INTEGER {normallyClosed(0), normallyOpen(1)}read-writecurrent
tlpCoolingOutputContactType
OBJECT-TYPE
The output contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.7INTEGER {normallyClosed(0), normallyOpen(1)}read-writecurrent
tlpCoolingOutputRelaySource
OBJECT-TYPE
The alarm level that causes the output relay to activate. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.8INTEGER {disabled(0), allAlarmsAndWarnings(1), criticalAlarmsOnly(2)}read-writecurrent
tlpCoolingOutputRelayDefault
OBJECT-TYPE
Type of contact to make when output relay is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.9INTEGER {normallyClosed(0), normallyOpen(1)}read-writecurrent
tlpCoolingOffOnInputContact
OBJECT-TYPE
Indicates if the unit should stop cooling when input contact is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.10INTEGER {turnOff(0), alarmOnly(1)}read-writecurrent
tlpCoolingOffOnLeak
OBJECT-TYPE
Indicates if the unit should stop cooling when leak input is activated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.11INTEGER {turnOff(0), alarmOnly(1)}read-writecurrent
tlpCoolingWaterLeakContactType
OBJECT-TYPE
The water leak contact type. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.12INTEGER {normallyClosed(0), normallyOpen(1)}read-writecurrent
tlpCoolingAirFilterInterval
OBJECT-TYPE
The number of weeks before the air filter needs to be changed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.13Unsigned32read-writecurrent
tlpCoolingAirFilterAlarm
OBJECT-TYPE
When enabled, an alarm should occur when the maximum number of air filter run hours has been exceeded. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.14INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingMaxAirFilterRunHours
OBJECT-TYPE
The maximum interval for air filter run hours before warning is annunciated. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.15Unsigned32read-writecurrent
tlpCoolingStartTimer
OBJECT-TYPE
The unit will start operate after the specified timer elapsed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.16Unsigned32read-writecurrent
tlpCoolingStopTimer
OBJECT-TYPE
The unit will switch to standby mode after the specified timer elapsed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.17Unsigned32read-writecurrent
tlpCoolingEnergyMode
OBJECT-TYPE
This option enables or disables the energy saving mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.18INTEGER {normalCooling(0), energySaving(1)}read-writecurrent
tlpCoolingDefrostMode
OBJECT-TYPE
This option enables or disables the defrost mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.19INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingRemoteTemperatureSensor
OBJECT-TYPE
This option enables or disables the remote temperature sensor. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.20INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingDehumidifyingMode
OBJECT-TYPE
This option enables or disables the dehumidifying mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.21INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingFanAlwaysOn
OBJECT-TYPE
This option enables or disables the fan always on. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.22INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingQuietMode
OBJECT-TYPE
This option enables or disables the quiet mode. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.23INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingHotGasBypass
OBJECT-TYPE
This option enables or disables the hot gas bypass. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.24INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingAutoFanSpeed
OBJECT-TYPE
This option enables or disables the auto fan speed. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.1.1.25INTEGER {disabled(0), enabled(1)}read-writecurrent
tlpCoolingConfigTemperatureFahrenheitTable
OBJECT-TYPE
The configuration details for each each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device. Not all options are available on all cooling devices.
1.3.6.1.4.1.850.1.1.3.5.5.2not-accessiblecurrent
tlpCoolingConfigTemperatureFahrenheitEntry
OBJECT-TYPE
An entry configuration details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.5.2.1not-accessiblecurrent
tlpCoolingSetPointDegF
OBJECT-TYPE
The set point temperature the unit will control the temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.1Integer32read-writecurrent
tlpCoolingSupplyAirHighLimitDegF
OBJECT-TYPE
Maximum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.2Integer32read-writecurrent
tlpCoolingSupplyAirLowLimitDegF
OBJECT-TYPE
Minimum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.3Integer32read-writecurrent
tlpCoolingMaxDeviationLimitDegF
OBJECT-TYPE
Maximum allowed air temperature deviation from set temperature before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.4Integer32read-writecurrent
tlpCoolingReturnAirHighLimitDegF
OBJECT-TYPE
Maximum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.5Integer32read-writecurrent
tlpCoolingReturnAirLowLimitDegF
OBJECT-TYPE
Minimum allowed supply air temperature in tenths degrees Fahrenheit before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.6Integer32read-writecurrent
tlpCoolingRemoteSetPointDegF
OBJECT-TYPE
The remote set point temperature the unit will control the temperature in tenths degrees Fahrenheit. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.2.1.7Integer32read-writecurrent
tlpCoolingConfigTemperatureCelsiusTable
OBJECT-TYPE
The configuration details for each cooling device in device table. This is a sparse dependent table, and will contain some subset of devices that are cooling device. Not all options are available on all cooling devices.
1.3.6.1.4.1.850.1.1.3.5.5.3not-accessiblecurrent
tlpCoolingConfigTemperatureCelsiusEntry
OBJECT-TYPE
An entry configuration details for a particular cooling device.
1.3.6.1.4.1.850.1.1.3.5.5.3.1not-accessiblecurrent
tlpCoolingSetPointDegC
OBJECT-TYPE
The set point temperature the unit will control the temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.1Integer32read-writecurrent
tlpCoolingSupplyAirHighLimitDegC
OBJECT-TYPE
Maximum allowed supply air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.2Integer32read-writecurrent
tlpCoolingSupplyAirLowLimitDegC
OBJECT-TYPE
Minimum allowed supply air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.3Integer32read-writecurrent
tlpCoolingMaxDeviationLimitDegC
OBJECT-TYPE
Maximum allowed air temperature deviation from set temperature before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.4Integer32read-writecurrent
tlpCoolingReturnAirHighLimitDegC
OBJECT-TYPE
Maximum allowed return air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.5Integer32read-writecurrent
tlpCoolingReturnAirLowLimitDegC
OBJECT-TYPE
Minimum allowed return air temperature in tenths degrees Celsius before firing an alarm. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.6Integer32read-writecurrent
tlpCoolingRemoteSetPointDegC
OBJECT-TYPE
The remote set point temperature the unit will control the temperature in tenths degrees Celsius. If not supported, this value will always return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.1.3.5.5.3.1.7Integer32read-writecurrent
tlpKvm
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.6
tlpKvmIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.6.1
tlpKvmIdentNumKvm
OBJECT-TYPE
The number of kvm devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.6.1.1Unsigned32read-onlycurrent
tlpKvmDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.6.2
tlpKvmDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.6.3
tlpKvmControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.6.4
tlpKvmConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.6.5
tlpRackTrack
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.7
tlpRackTrackIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.7.1
tlpRackTrackIdentNumRackTrack
OBJECT-TYPE
The number of rack track devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.7.1.1Unsigned32read-onlycurrent
tlpRackTrackDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.7.2
tlpRackTrackDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.7.3
tlpRackTrackControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.7.4
tlpRackTrackConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.7.5
tlpSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.8
tlpSwitchIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.8.1
tlpSwitchIdentNumSwitch
OBJECT-TYPE
The number of switch devices that this agent is currently managing.
1.3.6.1.4.1.850.1.1.3.8.1.1Unsigned32read-onlycurrent
tlpSwitchDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.8.2
tlpSwitchDetail
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.8.3
tlpSwitchControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.8.4
tlpSwitchConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.1.3.8.5
tlpSoftware
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2
tlpAgentDetails
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1
tlpAgentIdent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1.1
tlpAgentType
OBJECT-TYPE
The type of PowerAlert engine providing this data.
1.3.6.1.4.1.850.1.2.1.1.1INTEGER {unknown(0), pal(1), pansa(2), delta(3), sinetica(4), netos6(5), netos7(6), panms(7), nmc5(8)}read-onlycurrent
tlpAgentVersion
OBJECT-TYPE
The version of the agent software.
1.3.6.1.4.1.850.1.2.1.1.2DisplayStringread-onlycurrent
tlpAgentDriverVersion
OBJECT-TYPE
The driver version of the agent software.
1.3.6.1.4.1.850.1.2.1.1.3DisplayStringread-onlycurrent
tlpAgentMAC
OBJECT-TYPE
The MAC Address of the agent.
1.3.6.1.4.1.850.1.2.1.1.4DisplayStringread-onlycurrent
tlpAgentSerialNum
OBJECT-TYPE
Serial number of the web card providing the agent data. This value is only supported by a web card agent. PowerAlert for PC (PAL) agents do not support this value and will return ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.850.1.2.1.1.5DisplayStringread-onlycurrent
tlpAgentUuid
OBJECT-TYPE
Universally unique identifier for this host in the form 8-4-4-4-12 for a total of 36 characters (32 alphanumeric characters and four hyphens). For example: 550e8400-e29b-41d4-a716-446655440000.
1.3.6.1.4.1.850.1.2.1.1.6DisplayStringread-onlycurrent
tlpAgentAttributes
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1.2
tlpAgentAttributesSupports
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1.2.1
tlpAgentAttributesSupportsHTTP
OBJECT-TYPE
Indicates whether the agent supports HTTP connections.
1.3.6.1.4.1.850.1.2.1.2.1.1TruthValueread-onlycurrent
tlpAgentAttributesSupportsHTTPS
OBJECT-TYPE
Indicates whether the agent supports HTTPS connections.
1.3.6.1.4.1.850.1.2.1.2.1.2TruthValueread-onlycurrent
tlpAgentAttributesSupportsFTP
OBJECT-TYPE
Indicates whether the agent supports FTP connections.
1.3.6.1.4.1.850.1.2.1.2.1.3TruthValueread-onlycurrent
tlpAgentAttributesSupportsTelnetMenu
OBJECT-TYPE
Indicates whether the agent supports Telnet menu connections.
1.3.6.1.4.1.850.1.2.1.2.1.4TruthValueread-onlycurrent
tlpAgentAttributesSupportsTelnetCLI
OBJECT-TYPE
Indicates whether the agent supports Telnet CLI connections.
1.3.6.1.4.1.850.1.2.1.2.1.5TruthValueread-onlycurrent
tlpAgentAttributesSupportsSSHMenu
OBJECT-TYPE
Indicates whether the agent supports SSH menu connections.
1.3.6.1.4.1.850.1.2.1.2.1.6TruthValueread-onlycurrent
tlpAgentAttributesSupportsSSHCLI
OBJECT-TYPE
Indicates whether the agent supports SSH CLI connections.
1.3.6.1.4.1.850.1.2.1.2.1.7TruthValueread-onlycurrent
tlpAgentAttributesSupportsSNMP
OBJECT-TYPE
Indicates whether the agent supports SNMP connections.
1.3.6.1.4.1.850.1.2.1.2.1.8TruthValueread-onlycurrent
tlpAgentAttributesSupportsSNMPTrap
OBJECT-TYPE
Indicates whether the agent supports listening for SNMP traps. This is only applicable for network monitoring applications, PowerAlert Shutdown Agent for an example, that connect to a web card or PowerAlert Local and listen for outbound traps. As such, this value is not supported and will always return 2(false) for a web card or PowerAlert Local.
1.3.6.1.4.1.850.1.2.1.2.1.9TruthValueread-onlycurrent
tlpAgentAttributesAutostart
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1.2.2
tlpAgentAttributesAutostartHTTP
OBJECT-TYPE
Indicates whether the agent autostarts HTTP services.
1.3.6.1.4.1.850.1.2.1.2.2.1TruthValueread-onlycurrent
tlpAgentAttributesAutostartHTTPS
OBJECT-TYPE
Indicates whether the agent autostarts HTTPS services.
1.3.6.1.4.1.850.1.2.1.2.2.2TruthValueread-onlycurrent
tlpAgentAttributesAutostartFTP
OBJECT-TYPE
Indicates whether the agent autostarts FTP services.
1.3.6.1.4.1.850.1.2.1.2.2.3TruthValueread-onlycurrent
tlpAgentAttributesAutostartTelnetMenu
OBJECT-TYPE
Indicates whether the agent autostarts Telnet menu services.
1.3.6.1.4.1.850.1.2.1.2.2.4TruthValueread-onlycurrent
tlpAgentAttributesAutostartTelnetCLI
OBJECT-TYPE
Indicates whether the agent autostarts Telnet CLI services.
1.3.6.1.4.1.850.1.2.1.2.2.5TruthValueread-onlycurrent
tlpAgentAttributesAutostartSSHMenu
OBJECT-TYPE
Indicates whether the agent autostarts SSH menu services.
1.3.6.1.4.1.850.1.2.1.2.2.6TruthValueread-onlycurrent
tlpAgentAttributesAutostartSSHCLI
OBJECT-TYPE
Indicates whether the agent autostarts SSH CLI services.
1.3.6.1.4.1.850.1.2.1.2.2.7TruthValueread-onlycurrent
tlpAgentAttributesAutostartSNMP
OBJECT-TYPE
Indicates whether the agent autostarts SNMP services.
1.3.6.1.4.1.850.1.2.1.2.2.8TruthValueread-onlycurrent
tlpAgentAttributesSnmp
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1.2.3
tlpAgentAttributesSNMPv1Enabled
OBJECT-TYPE
Indicates whether the agent will allow SNMPv1 connections.
1.3.6.1.4.1.850.1.2.1.2.3.1TruthValueread-onlycurrent
tlpAgentAttributesSNMPv2cEnabled
OBJECT-TYPE
Indicates whether the agent will allow SNMPv2c connections.
1.3.6.1.4.1.850.1.2.1.2.3.2TruthValueread-onlycurrent
tlpAgentAttributesSNMPv3Enabled
OBJECT-TYPE
Indicates whether the agent will allow SNMPv3 connections.
1.3.6.1.4.1.850.1.2.1.2.3.3TruthValueread-onlycurrent
tlpAgentAttributesPorts
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.1.2.4
tlpAgentAttributesHTTPPort
OBJECT-TYPE
The port used for HTTP communications.
1.3.6.1.4.1.850.1.2.1.2.4.1Unsigned32read-onlycurrent
tlpAgentAttributesHTTPSPort
OBJECT-TYPE
The port used for HTTPS communications.
1.3.6.1.4.1.850.1.2.1.2.4.2Unsigned32read-onlycurrent
tlpAgentAttributesFTPPort
OBJECT-TYPE
The port used for FTP communications.
1.3.6.1.4.1.850.1.2.1.2.4.3Unsigned32read-onlycurrent
tlpAgentAttributesTelnetMenuPort
OBJECT-TYPE
The port used for Telnet Menu communications.
1.3.6.1.4.1.850.1.2.1.2.4.4Unsigned32read-onlycurrent
tlpAgentAttributesTelnetCLIPort
OBJECT-TYPE
The port used for Telnet CLI communications.
1.3.6.1.4.1.850.1.2.1.2.4.5Unsigned32read-onlycurrent
tlpAgentAttributesSSHMenuPort
OBJECT-TYPE
The port used for SSH Menu communications.
1.3.6.1.4.1.850.1.2.1.2.4.6Unsigned32read-onlycurrent
tlpAgentAttributesSSHCLIPort
OBJECT-TYPE
The port used for SSH CLI communications.
1.3.6.1.4.1.850.1.2.1.2.4.7Unsigned32read-onlycurrent
tlpAgentAttributesSNMPPort
OBJECT-TYPE
The port used for SNMP communications.
1.3.6.1.4.1.850.1.2.1.2.4.8Unsigned32read-onlycurrent
tlpAgentAttributesSNMPTrapPort
OBJECT-TYPE
The port used for SNMP trap and notifications.
1.3.6.1.4.1.850.1.2.1.2.4.9Unsigned32read-onlycurrent
tlpAgentSettings
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.2
tlpAgentConfig
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.2.1
tlpAgentConfigRemoteRegistration
OBJECT-TYPE
Registers an SNMP contact's IP address and the port on which the contact is listening for SNMP traps. Setting this value is used to CREATE a table entry in a non-standard way. Getting this value will return a string INADDR_ANY and any port number. The port number should always be included. When unregistering an SNMP contact, the requester's IP address should be provided with a port number of 0. When setting or unsetting this OID, the IP address string should never be 0 nor should it be empty. The registration uses its default community string to register each contact. To use a community other than the default, then it must be appended to the end of the string delimited with a comma. The address should be of the format 0.0.0.0:00000 for IPv4. If IPv6 is supported, use the bracket-enclosed format given in IETF RFC 2732 Section 2, with the following examples: [FEDC:BA98:7654:3210:FEDC:BA98:7654:3210]:80 [1080:0:0:0:8:800:200C:417A]:162 [3ffe:2a00:100:7031::1]:162 [1080::8:800:200C:417A]:162,myCommunity [::192.9.5.5]:162,myCommunity [::FFFF:129.144.52.38]:80 [2010:836B:4179::836B:4179]:162
1.3.6.1.4.1.850.1.2.2.1.1DisplayStringread-writecurrent
tlpAgentConfigCurrentTime
OBJECT-TYPE
The current date and time of the system.
1.3.6.1.4.1.850.1.2.2.1.2DisplayStringread-writecurrent
tlpAgentContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.3
tlpAgentEmailContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.3.1
tlpAgentNumEmailContacts
OBJECT-TYPE
The number of email contacts currently defined in the agent.
1.3.6.1.4.1.850.1.2.3.1.1Unsigned32read-onlycurrent
tlpAgentEmailContactTable
OBJECT-TYPE
A list of email contact entries. The number of entries is given by the value of tlpAgentNumEmailContacts.
1.3.6.1.4.1.850.1.2.3.1.2not-accessiblecurrent
tlpAgentEmailContactEntry
OBJECT-TYPE
An entry containing the details of an email contact.
1.3.6.1.4.1.850.1.2.3.1.2.1not-accessiblecurrent
tlpAgentEmailContactIndex
OBJECT-TYPE
The table row index for the email contact.
1.3.6.1.4.1.850.1.2.3.1.2.1.1Unsigned32read-onlycurrent
tlpAgentEmailContactRowStatus
OBJECT-TYPE
Row status for the tlpAgentEmailContactTable.
1.3.6.1.4.1.850.1.2.3.1.2.1.2RowStatusread-writecurrent
tlpAgentEmailContactName
OBJECT-TYPE
The name of the email contact.
1.3.6.1.4.1.850.1.2.3.1.2.1.3DisplayStringread-writecurrent
tlpAgentEmailContactAddress
OBJECT-TYPE
The address of the email contact.
1.3.6.1.4.1.850.1.2.3.1.2.1.4DisplayStringread-writecurrent
tlpAgentSnmpContacts
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.2.3.2
tlpAgentNumSnmpContacts
OBJECT-TYPE
The number of SNMP contacts currently defined in the agent.
1.3.6.1.4.1.850.1.2.3.2.1Unsigned32read-onlycurrent
tlpAgentSnmpContactTable
OBJECT-TYPE
A list of SNMP contact entries. The number of entries is given by the value of tlpAgentNumSnmpContacts.
1.3.6.1.4.1.850.1.2.3.2.2not-accessiblecurrent
tlpAgentSnmpContactEntry
OBJECT-TYPE
An entry containing the details of an SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1not-accessiblecurrent
tlpAgentSnmpContactIndex
OBJECT-TYPE
The table row index for the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.1Unsigned32read-onlycurrent
tlpAgentSnmpContactRowStatus
OBJECT-TYPE
Row status for the tlpAgentSnmpContactTable.
1.3.6.1.4.1.850.1.2.3.2.2.1.2RowStatusread-writecurrent
tlpAgentSnmpContactName
OBJECT-TYPE
The name of the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.3DisplayStringread-writecurrent
tlpAgentSnmpContactIpAddress
OBJECT-TYPE
The IP address of the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.4DisplayStringread-writecurrent
tlpAgentSnmpContactPort
OBJECT-TYPE
The port of the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.5Unsigned32read-writecurrent
tlpAgentSnmpContactSnmpVersion
OBJECT-TYPE
The SNMP contact version to use for sending traps.
1.3.6.1.4.1.850.1.2.3.2.2.1.6INTEGER {snmpv1(1), snmpv2c(2), snmpv3(3)}read-writecurrent
tlpAgentSnmpContactSecurityName
OBJECT-TYPE
The security name for the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.7DisplayStringread-writecurrent
tlpAgentSnmpContactPrivPassword
OBJECT-TYPE
The privacy password to use for sending V3 traps to the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.8DisplayStringread-writeobsolete
tlpAgentSnmpContactAuthPassword
OBJECT-TYPE
The authentication password to use for sending V3 traps to the SNMP contact.
1.3.6.1.4.1.850.1.2.3.2.2.1.9DisplayStringread-writeobsolete
tlpAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3
tlpAlarmsPresent
OBJECT-TYPE
The present number of active alarm conditions.
1.3.6.1.4.1.850.1.3.1Unsigned32read-onlycurrent
tlpAlarmTable
OBJECT-TYPE
A list of alarm conditions for all devices managed by this agent. This table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect or conditions not acknowledged. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains (becomes inactive and is acknowledged). The agent creates the first row with tlpAlarmId equal to 1, and increments the value of tlpAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of tlpAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse (e.g., containing entries for rows 95, 100, 101, and 203) and the entries should not be assumed to be in chronological order because tlpAlarmId might have wrapped. The number of rows in the table at any given time is reflected by the value of tlpAlarmsPresent.
1.3.6.1.4.1.850.1.3.2not-accessiblecurrent
tlpAlarmEntry
OBJECT-TYPE
An entry containing information application to a particular alarm.
1.3.6.1.4.1.850.1.3.2.1not-accessiblecurrent
tlpAlarmId
OBJECT-TYPE
A unique identifier for an alarm condition. This value will remain constant for the duration of the alarm condition.
1.3.6.1.4.1.850.1.3.2.1.1Unsigned32read-onlycurrent
tlpAlarmDescr
OBJECT-TYPE
A reference of the alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active.
1.3.6.1.4.1.850.1.3.2.1.2OBJECT IDENTIFIERread-onlycurrent
tlpAlarmTime
OBJECT-TYPE
The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of tlpAlarmsTime shall equal 0.
1.3.6.1.4.1.850.1.3.2.1.3TimeStampread-onlycurrent
tlpAlarmTableRef
OBJECT-TYPE
This value references the OID of a table object applicable to the alarm condition. This, in conjunction with the table row as defined by tlpAlarmTableRowRef, specifies the object/row within this table to which the alarm condition applies. Example 1 -- The following sample values will be returned for a UPS on battery: tlpAlarmId 28 tlpAlarmDescr tlpUpsAlarmOnBattery tlpAlarmTime 12345678 tlpAlarmTableRef tlpDeviceTable tlpAlarmTableRowRef tlpDeviceIndex.2 tlpAlarmDetail On Battery tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged notAcknowledged In the above example, tlpAlarmTableRef references the device table and tlpAlarmTableRowRef references the 2nd managed device in that table. Example 2 -- The following sample values will be returned for a PDU with a load turned off: tlpAlarmId 46 tlpAlarmDescr tlpPduAlarmLoadOff tlpAlarmTime 12345678 tlpAlarmTableRef tlpPduOutletTable tlpAlarmTableRowRef tlpOutletIndex.1.4 tlpAlarmDetail Load Off tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged acknowledged In the above example, tlpAlarmTableRef references the pdu outlet table and tlpAlarmTableRowRef references the 4th outlet on the 1st managed device.
1.3.6.1.4.1.850.1.3.2.1.4OBJECT IDENTIFIERread-onlycurrent
tlpAlarmTableRowRef
OBJECT-TYPE
This value is used in conjunction with tlpAlarmTableRef to define the object associated with this alarm condition. See the description of tlpAlarmTableRef for more information.
1.3.6.1.4.1.850.1.3.2.1.5OBJECT IDENTIFIERread-onlycurrent
tlpAlarmDetail
OBJECT-TYPE
A textual description of the alarm condition.
1.3.6.1.4.1.850.1.3.2.1.6DisplayStringread-onlycurrent
tlpAlarmType
OBJECT-TYPE
The category/group of this alarm.
1.3.6.1.4.1.850.1.3.2.1.7INTEGER {critical(1), warning(2), info(3), status(4), offline(5), custom(6)}read-onlycurrent
tlpAlarmState
OBJECT-TYPE
The current state of this alarm condition. An active(1) alarm is a condition that currently exists. An inactive(2) alarm is a condition that no longer exists because the alarm either cleared or was resolved. Each alarm condition must be cleared and acknowledged before it is removed from this table (see tlpAlarmAcknowledged).
1.3.6.1.4.1.850.1.3.2.1.8INTEGER {active(1), inactive(2)}read-onlycurrent
tlpAlarmAcknowledged
OBJECT-TYPE
Denotes whether the alarm condition has been acknowledged. The agent will return notAcknowledged(1) if the condition has not been acknowledged, or acknowledged(2) when acknowledged. Writing the value acknowledged(2) for an alarm acknowledges the alarm condition. Each alarm condition must be cleared and acknowledged before it is removed from this table; therefore, even if acknowledged, the alarm will remain in this table until the alarm becomes inactive as denoted by tlpAlarmState.
1.3.6.1.4.1.850.1.3.2.1.9INTEGER {notAcknowledged(1), acknowledged(2)}read-writecurrent
tlpAlarmsWellKnown
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3
tlpAgentAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.1
tlpAutoProbeAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.1.1
tlpAutoProbeAlarm01
OBJECT-IDENTITY
Auto Probe 1 had failed
1.3.6.1.4.1.850.1.3.3.1.1.1current
tlpAutoProbeAlarm02
OBJECT-IDENTITY
Auto Probe 2 had failed
1.3.6.1.4.1.850.1.3.3.1.1.2current
tlpAutoProbeAlarm03
OBJECT-IDENTITY
Auto Probe 3 had failed
1.3.6.1.4.1.850.1.3.3.1.1.3current
tlpAutoProbeAlarm04
OBJECT-IDENTITY
Auto Probe 4 had failed
1.3.6.1.4.1.850.1.3.3.1.1.4current
tlpAutoProbeAlarm05
OBJECT-IDENTITY
Auto Probe 5 had failed
1.3.6.1.4.1.850.1.3.3.1.1.5current
tlpAutoProbeAlarm06
OBJECT-IDENTITY
Auto Probe 6 had failed
1.3.6.1.4.1.850.1.3.3.1.1.6current
tlpAutoProbeAlarm07
OBJECT-IDENTITY
Auto Probe 7 had failed
1.3.6.1.4.1.850.1.3.3.1.1.7current
tlpAutoProbeAlarm08
OBJECT-IDENTITY
Auto Probe 8 had failed
1.3.6.1.4.1.850.1.3.3.1.1.8current
tlpAutoProbeAlarm09
OBJECT-IDENTITY
Auto Probe 9 had failed
1.3.6.1.4.1.850.1.3.3.1.1.9current
tlpAutoProbeAlarm10
OBJECT-IDENTITY
Auto Probe 10 had failed
1.3.6.1.4.1.850.1.3.3.1.1.10current
tlpAutoProbeAlarm11
OBJECT-IDENTITY
Auto Probe 11 had failed
1.3.6.1.4.1.850.1.3.3.1.1.11current
tlpAutoProbeAlarm12
OBJECT-IDENTITY
Auto Probe 12 had failed
1.3.6.1.4.1.850.1.3.3.1.1.12current
tlpAutoProbeAlarm13
OBJECT-IDENTITY
Auto Probe 13 had failed
1.3.6.1.4.1.850.1.3.3.1.1.13current
tlpAutoProbeAlarm14
OBJECT-IDENTITY
Auto Probe 14 had failed
1.3.6.1.4.1.850.1.3.3.1.1.14current
tlpAutoProbeAlarm15
OBJECT-IDENTITY
Auto Probe 15 had failed
1.3.6.1.4.1.850.1.3.3.1.1.15current
tlpAutoProbeAlarm16
OBJECT-IDENTITY
Auto Probe 16 had failed
1.3.6.1.4.1.850.1.3.3.1.1.16current
tlpAutoProbeAlarm17
OBJECT-IDENTITY
Auto Probe 17 had failed
1.3.6.1.4.1.850.1.3.3.1.1.17current
tlpAutoProbeAlarm18
OBJECT-IDENTITY
Auto Probe 18 had failed
1.3.6.1.4.1.850.1.3.3.1.1.18current
tlpAutoProbeAlarm19
OBJECT-IDENTITY
Auto Probe 19 had failed
1.3.6.1.4.1.850.1.3.3.1.1.19current
tlpAutoProbeAlarm20
OBJECT-IDENTITY
Auto Probe 20 had failed
1.3.6.1.4.1.850.1.3.3.1.1.20current
tlpAutoProbeAlarm21
OBJECT-IDENTITY
Auto Probe 21 had failed
1.3.6.1.4.1.850.1.3.3.1.1.21current
tlpAutoProbeAlarm22
OBJECT-IDENTITY
Auto Probe 22 had failed
1.3.6.1.4.1.850.1.3.3.1.1.22current
tlpAutoProbeAlarm23
OBJECT-IDENTITY
Auto Probe 23 had failed
1.3.6.1.4.1.850.1.3.3.1.1.23current
tlpAutoProbeAlarm24
OBJECT-IDENTITY
Auto Probe 24 had failed
1.3.6.1.4.1.850.1.3.3.1.1.24current
tlpAutoProbeAlarm25
OBJECT-IDENTITY
Auto Probe 25 had failed
1.3.6.1.4.1.850.1.3.3.1.1.25current
tlpAutoProbeAlarm26
OBJECT-IDENTITY
Auto Probe 26 had failed
1.3.6.1.4.1.850.1.3.3.1.1.26current
tlpAutoProbeAlarm27
OBJECT-IDENTITY
Auto Probe 27 had failed
1.3.6.1.4.1.850.1.3.3.1.1.27current
tlpAutoProbeAlarm28
OBJECT-IDENTITY
Auto Probe 28 had failed
1.3.6.1.4.1.850.1.3.3.1.1.28current
tlpAutoProbeAlarm29
OBJECT-IDENTITY
Auto Probe 29 had failed
1.3.6.1.4.1.850.1.3.3.1.1.29current
tlpAutoProbeAlarm30
OBJECT-IDENTITY
Auto Probe 30 had failed
1.3.6.1.4.1.850.1.3.3.1.1.30current
tlpAutoProbeAlarm31
OBJECT-IDENTITY
Auto Probe 31 had failed
1.3.6.1.4.1.850.1.3.3.1.1.31current
tlpAutoProbeAlarm32
OBJECT-IDENTITY
Auto Probe 32 had failed
1.3.6.1.4.1.850.1.3.3.1.1.32current
tlpAutoProbeAlarm33
OBJECT-IDENTITY
Auto Probe 33 had failed
1.3.6.1.4.1.850.1.3.3.1.1.33current
tlpAutoProbeAlarm34
OBJECT-IDENTITY
Auto Probe 34 had failed
1.3.6.1.4.1.850.1.3.3.1.1.34current
tlpAutoProbeAlarm35
OBJECT-IDENTITY
Auto Probe 35 had failed
1.3.6.1.4.1.850.1.3.3.1.1.35current
tlpAutoProbeAlarm36
OBJECT-IDENTITY
Auto Probe 36 had failed
1.3.6.1.4.1.850.1.3.3.1.1.36current
tlpAutoProbeAlarm37
OBJECT-IDENTITY
Auto Probe 37 had failed
1.3.6.1.4.1.850.1.3.3.1.1.37current
tlpAutoProbeAlarm38
OBJECT-IDENTITY
Auto Probe 38 had failed
1.3.6.1.4.1.850.1.3.3.1.1.38current
tlpAutoProbeAlarm39
OBJECT-IDENTITY
Auto Probe 39 had failed
1.3.6.1.4.1.850.1.3.3.1.1.39current
tlpAutoProbeAlarm40
OBJECT-IDENTITY
Auto Probe 40 had failed
1.3.6.1.4.1.850.1.3.3.1.1.40current
tlpAutoProbeAlarm41
OBJECT-IDENTITY
Auto Probe 41 had failed
1.3.6.1.4.1.850.1.3.3.1.1.41current
tlpAutoProbeAlarm42
OBJECT-IDENTITY
Auto Probe 42 had failed
1.3.6.1.4.1.850.1.3.3.1.1.42current
tlpAutoProbeAlarm43
OBJECT-IDENTITY
Auto Probe 43 had failed
1.3.6.1.4.1.850.1.3.3.1.1.43current
tlpAutoProbeAlarm44
OBJECT-IDENTITY
Auto Probe 44 had failed
1.3.6.1.4.1.850.1.3.3.1.1.44current
tlpAutoProbeAlarm45
OBJECT-IDENTITY
Auto Probe 45 had failed
1.3.6.1.4.1.850.1.3.3.1.1.45current
tlpAutoProbeAlarm46
OBJECT-IDENTITY
Auto Probe 46 had failed
1.3.6.1.4.1.850.1.3.3.1.1.46current
tlpAutoProbeAlarm47
OBJECT-IDENTITY
Auto Probe 47 had failed
1.3.6.1.4.1.850.1.3.3.1.1.47current
tlpAutoProbeAlarm48
OBJECT-IDENTITY
Auto Probe 48 had failed
1.3.6.1.4.1.850.1.3.3.1.1.48current
tlpAutoProbeAlarm49
OBJECT-IDENTITY
Auto Probe 49 had failed
1.3.6.1.4.1.850.1.3.3.1.1.49current
tlpAutoProbeAlarm50
OBJECT-IDENTITY
Auto Probe 50 had failed
1.3.6.1.4.1.850.1.3.3.1.1.50current
tlpAutoProbeAlarm51
OBJECT-IDENTITY
Auto Probe 51 had failed
1.3.6.1.4.1.850.1.3.3.1.1.51current
tlpAutoProbeAlarm52
OBJECT-IDENTITY
Auto Probe 52 had failed
1.3.6.1.4.1.850.1.3.3.1.1.52current
tlpAutoProbeAlarm53
OBJECT-IDENTITY
Auto Probe 53 had failed
1.3.6.1.4.1.850.1.3.3.1.1.53current
tlpAutoProbeAlarm54
OBJECT-IDENTITY
Auto Probe 54 had failed
1.3.6.1.4.1.850.1.3.3.1.1.54current
tlpAutoProbeAlarm55
OBJECT-IDENTITY
Auto Probe 55 had failed
1.3.6.1.4.1.850.1.3.3.1.1.55current
tlpAutoProbeAlarm56
OBJECT-IDENTITY
Auto Probe 56 had failed
1.3.6.1.4.1.850.1.3.3.1.1.56current
tlpAutoProbeAlarm57
OBJECT-IDENTITY
Auto Probe 57 had failed
1.3.6.1.4.1.850.1.3.3.1.1.57current
tlpAutoProbeAlarm58
OBJECT-IDENTITY
Auto Probe 58 had failed
1.3.6.1.4.1.850.1.3.3.1.1.58current
tlpAutoProbeAlarm59
OBJECT-IDENTITY
Auto Probe 59 had failed
1.3.6.1.4.1.850.1.3.3.1.1.59current
tlpAutoProbeAlarm60
OBJECT-IDENTITY
Auto Probe 60 had failed
1.3.6.1.4.1.850.1.3.3.1.1.60current
tlpAutoProbeAlarm61
OBJECT-IDENTITY
Auto Probe 61 had failed
1.3.6.1.4.1.850.1.3.3.1.1.61current
tlpAutoProbeAlarm62
OBJECT-IDENTITY
Auto Probe 62 had failed
1.3.6.1.4.1.850.1.3.3.1.1.62current
tlpAutoProbeAlarm63
OBJECT-IDENTITY
Auto Probe 63 had failed
1.3.6.1.4.1.850.1.3.3.1.1.63current
tlpAutoProbeAlarm64
OBJECT-IDENTITY
Auto Probe 64 had failed
1.3.6.1.4.1.850.1.3.3.1.1.64current
tlpDeviceAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.2
tlpAlarmCommunicationsLost
OBJECT-IDENTITY
A problem has been encountered in the communications between the agent and the device.
1.3.6.1.4.1.850.1.3.3.2.1current
tlpAlarmUserDefined
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.2.2
tlpAlarmUserDefined01
OBJECT-IDENTITY
User-defined event 1 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.1current
tlpAlarmUserDefined02
OBJECT-IDENTITY
User-defined event 2 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.2current
tlpAlarmUserDefined03
OBJECT-IDENTITY
User-defined event 3 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.3current
tlpAlarmUserDefined04
OBJECT-IDENTITY
User-defined event 4 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.4current
tlpAlarmUserDefined05
OBJECT-IDENTITY
User-defined event 5 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.5current
tlpAlarmUserDefined06
OBJECT-IDENTITY
User-defined event 6 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.6current
tlpAlarmUserDefined07
OBJECT-IDENTITY
User-defined event 7 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.7current
tlpAlarmUserDefined08
OBJECT-IDENTITY
User-defined event 8 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.8current
tlpAlarmUserDefined09
OBJECT-IDENTITY
User-defined event 9 is in alarm.
1.3.6.1.4.1.850.1.3.3.2.2.9current
tlpAlarmInternalFirmwareError
OBJECT-IDENTITY
A problem has been encountered with the device firmware.
1.3.6.1.4.1.850.1.3.3.2.3current
tlpAlarmDeviceEEPROMFault
OBJECT-IDENTITY
A problem has been encountered with the device EEPROM.
1.3.6.1.4.1.850.1.3.3.2.4current
tlpUpsAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.3
tlpUpsAlarmBatteryBad
OBJECT-IDENTITY
One or more batteries have been determined to require replacement.
1.3.6.1.4.1.850.1.3.3.3.1current
tlpUpsAlarmOnBattery
OBJECT-IDENTITY
The UPS is drawing power from the batteries.
1.3.6.1.4.1.850.1.3.3.3.2current
tlpUpsAlarmLowBattery
OBJECT-IDENTITY
The remaining battery charge is less than or equal to the percentage of capacity warning specified by tlpUpsConfigBatteryCapacityThreshold.
1.3.6.1.4.1.850.1.3.3.3.3current
tlpUpsAlarmDepletedBattery
OBJECT-IDENTITY
The UPS will be unable to sustain the present load when and if the utility power is lost.
1.3.6.1.4.1.850.1.3.3.3.4current
tlpUpsAlarmTempBad
OBJECT-IDENTITY
A temperature is out of tolerance.
1.3.6.1.4.1.850.1.3.3.3.5current
tlpUpsAlarmInputBad
OBJECT-IDENTITY
An input condition is out of tolerance.
1.3.6.1.4.1.850.1.3.3.3.6current
tlpUpsAlarmOutputBad
OBJECT-IDENTITY
An output condition (other than OutputOverload) is out of tolerance.
1.3.6.1.4.1.850.1.3.3.3.7current
tlpUpsAlarmOutputOverload
OBJECT-IDENTITY
The output load exceeds the UPS output capacity.
1.3.6.1.4.1.850.1.3.3.3.8current
tlpUpsAlarmOnBypass
OBJECT-IDENTITY
The Bypass is presently engaged on the UPS.
1.3.6.1.4.1.850.1.3.3.3.9current
tlpUpsAlarmBypassBad
OBJECT-IDENTITY
The Bypass is out of tolerance.
1.3.6.1.4.1.850.1.3.3.3.10current
tlpUpsAlarmOutputOffAsRequested
OBJECT-IDENTITY
The UPS has shutdown as requested, i.e., the output is off.
1.3.6.1.4.1.850.1.3.3.3.11current
tlpUpsAlarmUpsOffAsRequested
OBJECT-IDENTITY
The entire UPS has shutdown as commanded.
1.3.6.1.4.1.850.1.3.3.3.12current
tlpUpsAlarmChargerFailed
OBJECT-IDENTITY
An uncorrected problem has been detected within the UPS charger subsystem.
1.3.6.1.4.1.850.1.3.3.3.13current
tlpUpsAlarmUpsOutputOff
OBJECT-IDENTITY
The output of the UPS is in the off state.
1.3.6.1.4.1.850.1.3.3.3.14current
tlpUpsAlarmUpsSystemOff
OBJECT-IDENTITY
The UPS system is in the off state.
1.3.6.1.4.1.850.1.3.3.3.15current
tlpUpsAlarmFanFailure
OBJECT-IDENTITY
The failure of one or more fans in the UPS has been detected.
1.3.6.1.4.1.850.1.3.3.3.16current
tlpUpsAlarmFuseFailure
OBJECT-IDENTITY
The failure of one or more fuses has been detected.
1.3.6.1.4.1.850.1.3.3.3.17current
tlpUpsAlarmGeneralFault
OBJECT-IDENTITY
A general fault in the UPS has been detected.
1.3.6.1.4.1.850.1.3.3.3.18current
tlpUpsAlarmDiagnosticTestFailed
OBJECT-IDENTITY
The result of the last diagnostic test indicates a failure.
1.3.6.1.4.1.850.1.3.3.3.19current
tlpUpsAlarmAwaitingPower
OBJECT-IDENTITY
The UPS output is off and the UPS is awaiting the return of input power.
1.3.6.1.4.1.850.1.3.3.3.20current
tlpUpsAlarmShutdownPending
OBJECT-IDENTITY
A tlpUpsShutdownAfterDelay countdown is underway.
1.3.6.1.4.1.850.1.3.3.3.21current
tlpUpsAlarmShutdownImminent
OBJECT-IDENTITY
The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.
1.3.6.1.4.1.850.1.3.3.3.22current
tlpUpsAlarmLoadLevelAboveThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.3.23
tlpUpsAlarmLoadLevelAboveThresholdTotal
OBJECT-IDENTITY
The total load level is above the designated threshold.
1.3.6.1.4.1.850.1.3.3.3.23.1current
tlpUpsAlarmLoadLevelAboveThresholdPhase1
OBJECT-IDENTITY
The load level on phase 1 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.3.23.2current
tlpUpsAlarmLoadLevelAboveThresholdPhase2
OBJECT-IDENTITY
The load level on phase 2 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.3.23.3current
tlpUpsAlarmLoadLevelAboveThresholdPhase3
OBJECT-IDENTITY
The load level on phase 3 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.3.23.4current
tlpUpsAlarmOutputCurrentChanged
OBJECT-IDENTITY
The output current changed from its last known value.
1.3.6.1.4.1.850.1.3.3.3.24current
tlpUpsAlarmBatteryAgeAboveThreshold
OBJECT-IDENTITY
One or more batteries have been determined to require replacement.
1.3.6.1.4.1.850.1.3.3.3.25current
tlpUpsAlarmLoadOff
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.3.26
tlpUpsAlarmLoadOff01
OBJECT-IDENTITY
Load 1 is off.
1.3.6.1.4.1.850.1.3.3.3.26.1current
tlpUpsAlarmLoadOff02
OBJECT-IDENTITY
Load 2 is off.
1.3.6.1.4.1.850.1.3.3.3.26.2current
tlpUpsAlarmLoadOff03
OBJECT-IDENTITY
Load 3 is off.
1.3.6.1.4.1.850.1.3.3.3.26.3current
tlpUpsAlarmLoadOff04
OBJECT-IDENTITY
Load 4 is off.
1.3.6.1.4.1.850.1.3.3.3.26.4current
tlpUpsAlarmLoadOff05
OBJECT-IDENTITY
Load 5 is off.
1.3.6.1.4.1.850.1.3.3.3.26.5current
tlpUpsAlarmLoadOff06
OBJECT-IDENTITY
Load 6 is off.
1.3.6.1.4.1.850.1.3.3.3.26.6current
tlpUpsAlarmLoadOff07
OBJECT-IDENTITY
Load 7 is off.
1.3.6.1.4.1.850.1.3.3.3.26.7current
tlpUpsAlarmLoadOff08
OBJECT-IDENTITY
Load 8 is off.
1.3.6.1.4.1.850.1.3.3.3.26.8current
tlpUpsAlarmLoadOff09
OBJECT-IDENTITY
Load 9 is off.
1.3.6.1.4.1.850.1.3.3.3.26.9current
tlpUpsAlarmLoadOff10
OBJECT-IDENTITY
Load 10 is off.
1.3.6.1.4.1.850.1.3.3.3.26.10current
tlpUpsAlarmLoadOff11
OBJECT-IDENTITY
Load 11 is off.
1.3.6.1.4.1.850.1.3.3.3.26.11current
tlpUpsAlarmLoadOff12
OBJECT-IDENTITY
Load 12 is off.
1.3.6.1.4.1.850.1.3.3.3.26.12current
tlpUpsAlarmLoadOff13
OBJECT-IDENTITY
Load 13 is off.
1.3.6.1.4.1.850.1.3.3.3.26.13current
tlpUpsAlarmLoadOff14
OBJECT-IDENTITY
Load 14 is off.
1.3.6.1.4.1.850.1.3.3.3.26.14current
tlpUpsAlarmLoadOff15
OBJECT-IDENTITY
Load 15 is off.
1.3.6.1.4.1.850.1.3.3.3.26.15current
tlpUpsAlarmLoadOff16
OBJECT-IDENTITY
Load 16 is off.
1.3.6.1.4.1.850.1.3.3.3.26.16current
tlpUpsAlarmLoadOff17
OBJECT-IDENTITY
Load 17 is off.
1.3.6.1.4.1.850.1.3.3.3.26.17current
tlpUpsAlarmLoadOff18
OBJECT-IDENTITY
Load 18 is off.
1.3.6.1.4.1.850.1.3.3.3.26.18current
tlpUpsAlarmLoadOff19
OBJECT-IDENTITY
Load 19 is off.
1.3.6.1.4.1.850.1.3.3.3.26.19current
tlpUpsAlarmLoadOff20
OBJECT-IDENTITY
Load 20 is off.
1.3.6.1.4.1.850.1.3.3.3.26.20current
tlpUpsAlarmLoadOff21
OBJECT-IDENTITY
Load 21 is off.
1.3.6.1.4.1.850.1.3.3.3.26.21current
tlpUpsAlarmLoadOff22
OBJECT-IDENTITY
Load 22 is off.
1.3.6.1.4.1.850.1.3.3.3.26.22current
tlpUpsAlarmLoadOff23
OBJECT-IDENTITY
Load 23 is off.
1.3.6.1.4.1.850.1.3.3.3.26.23current
tlpUpsAlarmLoadOff24
OBJECT-IDENTITY
Load 24 is off.
1.3.6.1.4.1.850.1.3.3.3.26.24current
tlpUpsAlarmLoadOff25
OBJECT-IDENTITY
Load 25 is off.
1.3.6.1.4.1.850.1.3.3.3.26.25current
tlpUpsAlarmLoadOff26
OBJECT-IDENTITY
Load 26 is off.
1.3.6.1.4.1.850.1.3.3.3.26.26current
tlpUpsAlarmLoadOff27
OBJECT-IDENTITY
Load 27 is off.
1.3.6.1.4.1.850.1.3.3.3.26.27current
tlpUpsAlarmLoadOff28
OBJECT-IDENTITY
Load 28 is off.
1.3.6.1.4.1.850.1.3.3.3.26.28current
tlpUpsAlarmLoadOff29
OBJECT-IDENTITY
Load 29 is off.
1.3.6.1.4.1.850.1.3.3.3.26.29current
tlpUpsAlarmLoadOff30
OBJECT-IDENTITY
Load 30 is off.
1.3.6.1.4.1.850.1.3.3.3.26.30current
tlpUpsAlarmLoadOff31
OBJECT-IDENTITY
Load 31 is off.
1.3.6.1.4.1.850.1.3.3.3.26.31current
tlpUpsAlarmLoadOff32
OBJECT-IDENTITY
Load 32 is off.
1.3.6.1.4.1.850.1.3.3.3.26.32current
tlpUpsAlarmLoadOff33
OBJECT-IDENTITY
Load 33 is off.
1.3.6.1.4.1.850.1.3.3.3.26.33current
tlpUpsAlarmLoadOff34
OBJECT-IDENTITY
Load 34 is off.
1.3.6.1.4.1.850.1.3.3.3.26.34current
tlpUpsAlarmLoadOff35
OBJECT-IDENTITY
Load 35 is off.
1.3.6.1.4.1.850.1.3.3.3.26.35current
tlpUpsAlarmLoadOff36
OBJECT-IDENTITY
Load 36 is off.
1.3.6.1.4.1.850.1.3.3.3.26.36current
tlpUpsAlarmLoadOff37
OBJECT-IDENTITY
Load 37 is off.
1.3.6.1.4.1.850.1.3.3.3.26.37current
tlpUpsAlarmLoadOff38
OBJECT-IDENTITY
Load 38 is off.
1.3.6.1.4.1.850.1.3.3.3.26.38current
tlpUpsAlarmLoadOff39
OBJECT-IDENTITY
Load 39 is off.
1.3.6.1.4.1.850.1.3.3.3.26.39current
tlpUpsAlarmLoadOff40
OBJECT-IDENTITY
Load 40 is off.
1.3.6.1.4.1.850.1.3.3.3.26.40current
tlpUpsAlarmCurrentAboveThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.3.27
tlpUpsAlarmCurrentAboveThreshold1
OBJECT-IDENTITY
The output current on phase 1 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.3.27.1current
tlpUpsAlarmCurrentAboveThreshold2
OBJECT-IDENTITY
The output current on phase 2 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.3.27.2current
tlpUpsAlarmCurrentAboveThreshold3
OBJECT-IDENTITY
The output current on phase 3 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.3.27.3current
tlpUpsAlarmRuntimeBelowWarningLevel
OBJECT-IDENTITY
The battery seconds remaining is below warning level.
1.3.6.1.4.1.850.1.3.3.3.28current
tlpUpsAlarmBusStartVoltageLow
OBJECT-IDENTITY
The inverter start up bus voltage is too low.
1.3.6.1.4.1.850.1.3.3.3.29current
tlpUpsAlarmBusOverVoltage
OBJECT-IDENTITY
The inverter bus voltage is too high.
1.3.6.1.4.1.850.1.3.3.3.30current
tlpUpsAlarmBusUnderVoltage
OBJECT-IDENTITY
The inverter bus voltage is too low.
1.3.6.1.4.1.850.1.3.3.3.31current
tlpUpsAlarmBusVoltageUnbalanced
OBJECT-IDENTITY
The inverter bus voltage is not balanced.
1.3.6.1.4.1.850.1.3.3.3.32current
tlpUpsAlarmInverterSoftStartBad
OBJECT-IDENTITY
The inverter bus voltage cannot reach desired voltage within a specified duration.
1.3.6.1.4.1.850.1.3.3.3.33current
tlpUpsAlarmInverterOverVoltage
OBJECT-IDENTITY
The inverter voltage is too high.
1.3.6.1.4.1.850.1.3.3.3.34current
tlpUpsAlarmInverterUnderVoltage
OBJECT-IDENTITY
The inverter voltage is too low.
1.3.6.1.4.1.850.1.3.3.3.35current
tlpUpsAlarmInverterCircuitBad
OBJECT-IDENTITY
The inverter output is shorted.
1.3.6.1.4.1.850.1.3.3.3.36current
tlpUpsAlarmBatteryOverVoltage
OBJECT-IDENTITY
The battery voltage is too high.
1.3.6.1.4.1.850.1.3.3.3.37current
tlpUpsAlarmBatteryUnderVoltage
OBJECT-IDENTITY
The battery voltage is too low.
1.3.6.1.4.1.850.1.3.3.3.38current
tlpUpsAlarmSiteWiringFault
OBJECT-IDENTITY
The utility input wiring is faulty.
1.3.6.1.4.1.850.1.3.3.3.39current
tlpUpsAlarmOverTemperatureProtection
OBJECT-IDENTITY
The over temperature protection is activated.
1.3.6.1.4.1.850.1.3.3.3.40current
tlpUpsAlarmOverCharged
OBJECT-IDENTITY
The UPS is over charged.
1.3.6.1.4.1.850.1.3.3.3.41current
tlpUpsAlarmEPOActive
OBJECT-IDENTITY
The EPO is currently activated.
1.3.6.1.4.1.850.1.3.3.3.42current
tlpUpsAlarmBypassFrequencyBad
OBJECT-IDENTITY
The bypass frequency is out of tolerance.
1.3.6.1.4.1.850.1.3.3.3.43current
tlpUpsAlarmExternalSmartBatteryAgeAboveThreshold
OBJECT-IDENTITY
One or more external smart batteries have been determined to require replacement.
1.3.6.1.4.1.850.1.3.3.3.44current
tlpUpsAlarmExternalNonSmartBatteryAgeAboveThreshold
OBJECT-IDENTITY
One or more external non-smart batteries have been determined to require replacement.
1.3.6.1.4.1.850.1.3.3.3.45current
tlpUpsAlarmSmartBatteryCommLost
OBJECT-IDENTITY
Communications with the smart batteries was lost.
1.3.6.1.4.1.850.1.3.3.3.46current
tlpUpsAlarmLoadsNotAllOn
OBJECT-IDENTITY
One of more loads are not on.
1.3.6.1.4.1.850.1.3.3.3.47current
tlpUpsAlarmBatteryTemperatureHigh
OBJECT-IDENTITY
The battery temperature is high.
1.3.6.1.4.1.850.1.3.3.3.48current
tlpUpsAlarmBatteryTemperatureLow
OBJECT-IDENTITY
The battery temperature is low.
1.3.6.1.4.1.850.1.3.3.3.49current
tlpUpsAlarmBatteryDisconnected
OBJECT-IDENTITY
The battery disconnected.
1.3.6.1.4.1.850.1.3.3.3.50current
tlpUpsAlarmBatteryTemperatureSensorDisconnected
OBJECT-IDENTITY
The battery temperature sensor disconnected.
1.3.6.1.4.1.850.1.3.3.3.51current
tlpUpsAlarmTemperatureDerating
OBJECT-IDENTITY
Power derating due to high environment temperature.
1.3.6.1.4.1.850.1.3.3.3.52current
tlpUpsAlarmInputContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.3.53
tlpUpsAlarmInputContact1
OBJECT-IDENTITY
Input contact 1 in alarm.
1.3.6.1.4.1.850.1.3.3.3.53.1current
tlpUpsAlarmOutputContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.3.54
tlpUpsAlarmOutputContact1
OBJECT-IDENTITY
Output contact 1 in alarm.
1.3.6.1.4.1.850.1.3.3.3.54.1current
tlpUpsAlarmOutputContact2
OBJECT-IDENTITY
Output contact 2 in alarm.
1.3.6.1.4.1.850.1.3.3.3.54.2current
tlpUpsAlarmOutputContact3
OBJECT-IDENTITY
Output contact 3 in alarm.
1.3.6.1.4.1.850.1.3.3.3.54.3current
tlpUpsAlarmOutputContact4
OBJECT-IDENTITY
Output contact 4 in alarm.
1.3.6.1.4.1.850.1.3.3.3.54.4current
tlpUpsAlarmOutputContact5
OBJECT-IDENTITY
Output contact 5 in alarm.
1.3.6.1.4.1.850.1.3.3.3.54.5current
tlpUpsAlarmOutputContact6
OBJECT-IDENTITY
Output contact 6 in alarm.
1.3.6.1.4.1.850.1.3.3.3.54.6current
tlpPduAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.4
tlpPduAlarmLoadLevelAboveThreshold
OBJECT-IDENTITY
The load level is above the designated threshold.
1.3.6.1.4.1.850.1.3.3.4.1current
tlpPduAlarmInputBad
OBJECT-IDENTITY
An input condition is out of tolerance.
1.3.6.1.4.1.850.1.3.3.4.2current
tlpPduAlarmOutputBad
OBJECT-IDENTITY
An output condition (other than OutputOverload) is out of tolerance.
1.3.6.1.4.1.850.1.3.3.4.3current
tlpPduAlarmOutputOverload
OBJECT-IDENTITY
The output load exceeds the pdu output capacity.
1.3.6.1.4.1.850.1.3.3.4.4current
tlpPduAlarmOutputOff
OBJECT-IDENTITY
The output of the pdu is in the off state.
1.3.6.1.4.1.850.1.3.3.4.5current
tlpPduAlarmLoadOff
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.4.6
tlpPduAlarmLoadOff01
OBJECT-IDENTITY
Load 1 is off.
1.3.6.1.4.1.850.1.3.3.4.6.1current
tlpPduAlarmLoadOff02
OBJECT-IDENTITY
Load 2 is off.
1.3.6.1.4.1.850.1.3.3.4.6.2current
tlpPduAlarmLoadOff03
OBJECT-IDENTITY
Load 3 is off.
1.3.6.1.4.1.850.1.3.3.4.6.3current
tlpPduAlarmLoadOff04
OBJECT-IDENTITY
Load 4 is off.
1.3.6.1.4.1.850.1.3.3.4.6.4current
tlpPduAlarmLoadOff05
OBJECT-IDENTITY
Load 5 is off.
1.3.6.1.4.1.850.1.3.3.4.6.5current
tlpPduAlarmLoadOff06
OBJECT-IDENTITY
Load 6 is off.
1.3.6.1.4.1.850.1.3.3.4.6.6current
tlpPduAlarmLoadOff07
OBJECT-IDENTITY
Load 7 is off.
1.3.6.1.4.1.850.1.3.3.4.6.7current
tlpPduAlarmLoadOff08
OBJECT-IDENTITY
Load 8 is off.
1.3.6.1.4.1.850.1.3.3.4.6.8current
tlpPduAlarmLoadOff09
OBJECT-IDENTITY
Load 9 is off.
1.3.6.1.4.1.850.1.3.3.4.6.9current
tlpPduAlarmLoadOff10
OBJECT-IDENTITY
Load 10 is off.
1.3.6.1.4.1.850.1.3.3.4.6.10current
tlpPduAlarmLoadOff11
OBJECT-IDENTITY
Load 11 is off.
1.3.6.1.4.1.850.1.3.3.4.6.11current
tlpPduAlarmLoadOff12
OBJECT-IDENTITY
Load 12 is off.
1.3.6.1.4.1.850.1.3.3.4.6.12current
tlpPduAlarmLoadOff13
OBJECT-IDENTITY
Load 13 is off.
1.3.6.1.4.1.850.1.3.3.4.6.13current
tlpPduAlarmLoadOff14
OBJECT-IDENTITY
Load 14 is off.
1.3.6.1.4.1.850.1.3.3.4.6.14current
tlpPduAlarmLoadOff15
OBJECT-IDENTITY
Load 15 is off.
1.3.6.1.4.1.850.1.3.3.4.6.15current
tlpPduAlarmLoadOff16
OBJECT-IDENTITY
Load 16 is off.
1.3.6.1.4.1.850.1.3.3.4.6.16current
tlpPduAlarmLoadOff17
OBJECT-IDENTITY
Load 17 is off.
1.3.6.1.4.1.850.1.3.3.4.6.17current
tlpPduAlarmLoadOff18
OBJECT-IDENTITY
Load 18 is off.
1.3.6.1.4.1.850.1.3.3.4.6.18current
tlpPduAlarmLoadOff19
OBJECT-IDENTITY
Load 19 is off.
1.3.6.1.4.1.850.1.3.3.4.6.19current
tlpPduAlarmLoadOff20
OBJECT-IDENTITY
Load 20 is off.
1.3.6.1.4.1.850.1.3.3.4.6.20current
tlpPduAlarmLoadOff21
OBJECT-IDENTITY
Load 21 is off.
1.3.6.1.4.1.850.1.3.3.4.6.21current
tlpPduAlarmLoadOff22
OBJECT-IDENTITY
Load 22 is off.
1.3.6.1.4.1.850.1.3.3.4.6.22current
tlpPduAlarmLoadOff23
OBJECT-IDENTITY
Load 23 is off.
1.3.6.1.4.1.850.1.3.3.4.6.23current
tlpPduAlarmLoadOff24
OBJECT-IDENTITY
Load 24 is off.
1.3.6.1.4.1.850.1.3.3.4.6.24current
tlpPduAlarmLoadOff25
OBJECT-IDENTITY
Load 25 is off.
1.3.6.1.4.1.850.1.3.3.4.6.25current
tlpPduAlarmLoadOff26
OBJECT-IDENTITY
Load 26 is off.
1.3.6.1.4.1.850.1.3.3.4.6.26current
tlpPduAlarmLoadOff27
OBJECT-IDENTITY
Load 27 is off.
1.3.6.1.4.1.850.1.3.3.4.6.27current
tlpPduAlarmLoadOff28
OBJECT-IDENTITY
Load 28 is off.
1.3.6.1.4.1.850.1.3.3.4.6.28current
tlpPduAlarmLoadOff29
OBJECT-IDENTITY
Load 29 is off.
1.3.6.1.4.1.850.1.3.3.4.6.29current
tlpPduAlarmLoadOff30
OBJECT-IDENTITY
Load 30 is off.
1.3.6.1.4.1.850.1.3.3.4.6.30current
tlpPduAlarmLoadOff31
OBJECT-IDENTITY
Load 31 is off.
1.3.6.1.4.1.850.1.3.3.4.6.31current
tlpPduAlarmLoadOff32
OBJECT-IDENTITY
Load 32 is off.
1.3.6.1.4.1.850.1.3.3.4.6.32current
tlpPduAlarmLoadOff33
OBJECT-IDENTITY
Load 33 is off.
1.3.6.1.4.1.850.1.3.3.4.6.33current
tlpPduAlarmLoadOff34
OBJECT-IDENTITY
Load 34 is off.
1.3.6.1.4.1.850.1.3.3.4.6.34current
tlpPduAlarmLoadOff35
OBJECT-IDENTITY
Load 35 is off.
1.3.6.1.4.1.850.1.3.3.4.6.35current
tlpPduAlarmLoadOff36
OBJECT-IDENTITY
Load 36 is off.
1.3.6.1.4.1.850.1.3.3.4.6.36current
tlpPduAlarmLoadOff37
OBJECT-IDENTITY
Load 37 is off.
1.3.6.1.4.1.850.1.3.3.4.6.37current
tlpPduAlarmLoadOff38
OBJECT-IDENTITY
Load 38 is off.
1.3.6.1.4.1.850.1.3.3.4.6.38current
tlpPduAlarmLoadOff39
OBJECT-IDENTITY
Load 39 is off.
1.3.6.1.4.1.850.1.3.3.4.6.39current
tlpPduAlarmLoadOff40
OBJECT-IDENTITY
Load 40 is off.
1.3.6.1.4.1.850.1.3.3.4.6.40current
tlpPduAlarmCircuitBreakerOpen
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.4.7
tlpPduAlarmCircuitBreakerOpen01
OBJECT-IDENTITY
Circuit breaker 1 is open.
1.3.6.1.4.1.850.1.3.3.4.7.1current
tlpPduAlarmCircuitBreakerOpen02
OBJECT-IDENTITY
Circuit breaker 2 is open.
1.3.6.1.4.1.850.1.3.3.4.7.2current
tlpPduAlarmCircuitBreakerOpen03
OBJECT-IDENTITY
Circuit breaker 3 is open.
1.3.6.1.4.1.850.1.3.3.4.7.3current
tlpPduAlarmCircuitBreakerOpen04
OBJECT-IDENTITY
Circuit breaker 4 is open.
1.3.6.1.4.1.850.1.3.3.4.7.4current
tlpPduAlarmCircuitBreakerOpen05
OBJECT-IDENTITY
Circuit breaker 5 is open.
1.3.6.1.4.1.850.1.3.3.4.7.5current
tlpPduAlarmCircuitBreakerOpen06
OBJECT-IDENTITY
Circuit breaker 6 is open.
1.3.6.1.4.1.850.1.3.3.4.7.6current
tlpPduAlarmCurrentAboveThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.4.8
tlpPduAlarmCurrentAboveThreshold1
OBJECT-IDENTITY
The output current on phase 1 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.4.8.1current
tlpPduAlarmCurrentAboveThreshold2
OBJECT-IDENTITY
The output current on phase 2 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.4.8.2current
tlpPduAlarmCurrentAboveThreshold3
OBJECT-IDENTITY
The output current on phase 3 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.4.8.3current
tlpPduAlarmLoadsNotAllOn
OBJECT-IDENTITY
One of more loads are not on.
1.3.6.1.4.1.850.1.3.3.4.9current
tlpPduAlarmLoadLevelBelowThreshold
OBJECT-IDENTITY
The load level is below the designated threshold.
1.3.6.1.4.1.850.1.3.3.4.10current
tlpPduAlarmCurrentBelowThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.4.11
tlpPduAlarmCurrentBelowThreshold1
OBJECT-IDENTITY
The output current on phase 1 below load limits.
1.3.6.1.4.1.850.1.3.3.4.11.1current
tlpPduAlarmCurrentBelowThreshold2
OBJECT-IDENTITY
The output current on phase 2 below load limits.
1.3.6.1.4.1.850.1.3.3.4.11.2current
tlpPduAlarmCurrentBelowThreshold3
OBJECT-IDENTITY
The output current on phase 3 below load limits.
1.3.6.1.4.1.850.1.3.3.4.11.3current
tlpEnvAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.5
tlpEnvAlarmTemperatureBeyondLimits
OBJECT-IDENTITY
The temperature exceeds limits.
1.3.6.1.4.1.850.1.3.3.5.1current
tlpEnvAlarmHumidityBeyondLimits
OBJECT-IDENTITY
The humidity exceeds limits.
1.3.6.1.4.1.850.1.3.3.5.2current
tlpEnvAlarmInputContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.5.3
tlpEnvAlarmInputContact01
OBJECT-IDENTITY
Input contact 1 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.3.1current
tlpEnvAlarmInputContact02
OBJECT-IDENTITY
Input contact 2 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.3.2current
tlpEnvAlarmInputContact03
OBJECT-IDENTITY
Input contact 3 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.3.3current
tlpEnvAlarmInputContact04
OBJECT-IDENTITY
Input contact 4 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.3.4current
tlpEnvAlarmOutputContact
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.5.4
tlpEnvAlarmOutputContact01
OBJECT-IDENTITY
Output contact 1 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.4.1current
tlpEnvAlarmOutputContact02
OBJECT-IDENTITY
Output contact 2 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.4.2current
tlpEnvAlarmOutputContact03
OBJECT-IDENTITY
Output contact 3 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.4.3current
tlpEnvAlarmOutputContact04
OBJECT-IDENTITY
Output contact 4 is in alarm.
1.3.6.1.4.1.850.1.3.3.5.4.4current
tlpAtsAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6
tlpAtsAlarmOutage
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.1
tlpAtsAlarmSource1Outage
OBJECT-IDENTITY
Input on source 1 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the primary source is not present.
1.3.6.1.4.1.850.1.3.3.6.1.1current
tlpAtsAlarmSource2Outage
OBJECT-IDENTITY
Input on source 2 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the secondary source is not present.
1.3.6.1.4.1.850.1.3.3.6.1.2current
tlpAtsAlarmTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.2
tlpAtsAlarmSystemTemperature
OBJECT-IDENTITY
The system temperature is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.2.1current
tlpAtsAlarmSource1Temperature
OBJECT-IDENTITY
The source 1 temperature is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.2.2current
tlpAtsAlarmSource2Temperature
OBJECT-IDENTITY
The source 2 temperature is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.2.3current
tlpAtsAlarmLoadLevelAboveThreshold
OBJECT-IDENTITY
The load level is above the designated threshold.
1.3.6.1.4.1.850.1.3.3.6.3current
tlpAtsAlarmInputBad
OBJECT-IDENTITY
An input condition is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.4current
tlpAtsAlarmOutputBad
OBJECT-IDENTITY
An output condition (other than OutputOverload) is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.5current
tlpAtsAlarmOutputOverload
OBJECT-IDENTITY
The output load exceeds the ats output capacity.
1.3.6.1.4.1.850.1.3.3.6.6current
tlpAtsAlarmOutputOff
OBJECT-IDENTITY
The output of the ats is in the off state.
1.3.6.1.4.1.850.1.3.3.6.7current
tlpAtsAlarmLoadOff
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.8
tlpAtsAlarmLoadOff01
OBJECT-IDENTITY
Load 1 is off.
1.3.6.1.4.1.850.1.3.3.6.8.1current
tlpAtsAlarmLoadOff02
OBJECT-IDENTITY
Load 2 is off.
1.3.6.1.4.1.850.1.3.3.6.8.2current
tlpAtsAlarmLoadOff03
OBJECT-IDENTITY
Load 3 is off.
1.3.6.1.4.1.850.1.3.3.6.8.3current
tlpAtsAlarmLoadOff04
OBJECT-IDENTITY
Load 4 is off.
1.3.6.1.4.1.850.1.3.3.6.8.4current
tlpAtsAlarmLoadOff05
OBJECT-IDENTITY
Load 5 is off.
1.3.6.1.4.1.850.1.3.3.6.8.5current
tlpAtsAlarmLoadOff06
OBJECT-IDENTITY
Load 6 is off.
1.3.6.1.4.1.850.1.3.3.6.8.6current
tlpAtsAlarmLoadOff07
OBJECT-IDENTITY
Load 7 is off.
1.3.6.1.4.1.850.1.3.3.6.8.7current
tlpAtsAlarmLoadOff08
OBJECT-IDENTITY
Load 8 is off.
1.3.6.1.4.1.850.1.3.3.6.8.8current
tlpAtsAlarmLoadOff09
OBJECT-IDENTITY
Load 9 is off.
1.3.6.1.4.1.850.1.3.3.6.8.9current
tlpAtsAlarmLoadOff10
OBJECT-IDENTITY
Load 10 is off.
1.3.6.1.4.1.850.1.3.3.6.8.10current
tlpAtsAlarmLoadOff11
OBJECT-IDENTITY
Load 11 is off.
1.3.6.1.4.1.850.1.3.3.6.8.11current
tlpAtsAlarmLoadOff12
OBJECT-IDENTITY
Load 12 is off.
1.3.6.1.4.1.850.1.3.3.6.8.12current
tlpAtsAlarmLoadOff13
OBJECT-IDENTITY
Load 13 is off.
1.3.6.1.4.1.850.1.3.3.6.8.13current
tlpAtsAlarmLoadOff14
OBJECT-IDENTITY
Load 14 is off.
1.3.6.1.4.1.850.1.3.3.6.8.14current
tlpAtsAlarmLoadOff15
OBJECT-IDENTITY
Load 15 is off.
1.3.6.1.4.1.850.1.3.3.6.8.15current
tlpAtsAlarmLoadOff16
OBJECT-IDENTITY
Load 16 is off.
1.3.6.1.4.1.850.1.3.3.6.8.16current
tlpAtsAlarmLoadOff17
OBJECT-IDENTITY
Load 17 is off.
1.3.6.1.4.1.850.1.3.3.6.8.17current
tlpAtsAlarmLoadOff18
OBJECT-IDENTITY
Load 18 is off.
1.3.6.1.4.1.850.1.3.3.6.8.18current
tlpAtsAlarmLoadOff19
OBJECT-IDENTITY
Load 19 is off.
1.3.6.1.4.1.850.1.3.3.6.8.19current
tlpAtsAlarmLoadOff20
OBJECT-IDENTITY
Load 20 is off.
1.3.6.1.4.1.850.1.3.3.6.8.20current
tlpAtsAlarmLoadOff21
OBJECT-IDENTITY
Load 21 is off.
1.3.6.1.4.1.850.1.3.3.6.8.21current
tlpAtsAlarmLoadOff22
OBJECT-IDENTITY
Load 22 is off.
1.3.6.1.4.1.850.1.3.3.6.8.22current
tlpAtsAlarmLoadOff23
OBJECT-IDENTITY
Load 23 is off.
1.3.6.1.4.1.850.1.3.3.6.8.23current
tlpAtsAlarmLoadOff24
OBJECT-IDENTITY
Load 24 is off.
1.3.6.1.4.1.850.1.3.3.6.8.24current
tlpAtsAlarmLoadOff25
OBJECT-IDENTITY
Load 25 is off.
1.3.6.1.4.1.850.1.3.3.6.8.25current
tlpAtsAlarmLoadOff26
OBJECT-IDENTITY
Load 26 is off.
1.3.6.1.4.1.850.1.3.3.6.8.26current
tlpAtsAlarmLoadOff27
OBJECT-IDENTITY
Load 27 is off.
1.3.6.1.4.1.850.1.3.3.6.8.27current
tlpAtsAlarmLoadOff28
OBJECT-IDENTITY
Load 28 is off.
1.3.6.1.4.1.850.1.3.3.6.8.28current
tlpAtsAlarmLoadOff29
OBJECT-IDENTITY
Load 29 is off.
1.3.6.1.4.1.850.1.3.3.6.8.29current
tlpAtsAlarmLoadOff30
OBJECT-IDENTITY
Load 30 is off.
1.3.6.1.4.1.850.1.3.3.6.8.30current
tlpAtsAlarmLoadOff31
OBJECT-IDENTITY
Load 31 is off.
1.3.6.1.4.1.850.1.3.3.6.8.31current
tlpAtsAlarmLoadOff32
OBJECT-IDENTITY
Load 32 is off.
1.3.6.1.4.1.850.1.3.3.6.8.32current
tlpAtsAlarmLoadOff33
OBJECT-IDENTITY
Load 33 is off.
1.3.6.1.4.1.850.1.3.3.6.8.33current
tlpAtsAlarmLoadOff34
OBJECT-IDENTITY
Load 34 is off.
1.3.6.1.4.1.850.1.3.3.6.8.34current
tlpAtsAlarmLoadOff35
OBJECT-IDENTITY
Load 35 is off.
1.3.6.1.4.1.850.1.3.3.6.8.35current
tlpAtsAlarmLoadOff36
OBJECT-IDENTITY
Load 36 is off.
1.3.6.1.4.1.850.1.3.3.6.8.36current
tlpAtsAlarmLoadOff37
OBJECT-IDENTITY
Load 37 is off.
1.3.6.1.4.1.850.1.3.3.6.8.37current
tlpAtsAlarmLoadOff38
OBJECT-IDENTITY
Load 38 is off.
1.3.6.1.4.1.850.1.3.3.6.8.38current
tlpAtsAlarmLoadOff39
OBJECT-IDENTITY
Load 39 is off.
1.3.6.1.4.1.850.1.3.3.6.8.39current
tlpAtsAlarmLoadOff40
OBJECT-IDENTITY
Load 40 is off.
1.3.6.1.4.1.850.1.3.3.6.8.40current
tlpAtsAlarmCircuitBreakerOpen
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.9
tlpAtsAlarmCircuitBreakerOpen01
OBJECT-IDENTITY
Circuit breaker 1 is open.
1.3.6.1.4.1.850.1.3.3.6.9.1current
tlpAtsAlarmCircuitBreakerOpen02
OBJECT-IDENTITY
Circuit breaker 2 is open.
1.3.6.1.4.1.850.1.3.3.6.9.2current
tlpAtsAlarmCircuitBreakerOpen03
OBJECT-IDENTITY
Circuit breaker 3 is open.
1.3.6.1.4.1.850.1.3.3.6.9.3current
tlpAtsAlarmCircuitBreakerOpen04
OBJECT-IDENTITY
Circuit breaker 4 is open.
1.3.6.1.4.1.850.1.3.3.6.9.4current
tlpAtsAlarmCircuitBreakerOpen05
OBJECT-IDENTITY
Circuit breaker 5 is open.
1.3.6.1.4.1.850.1.3.3.6.9.5current
tlpAtsAlarmCircuitBreakerOpen06
OBJECT-IDENTITY
Circuit breaker 6 is open.
1.3.6.1.4.1.850.1.3.3.6.9.6current
tlpAtsAlarmCurrentAboveThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.10
tlpAtsAlarmCurrentAboveThresholdA1
OBJECT-IDENTITY
The output current on input source 1 phase 1 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.6.10.1current
tlpAtsAlarmCurrentAboveThresholdA2
OBJECT-IDENTITY
The output current on input source 1 phase 2 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.6.10.2current
tlpAtsAlarmCurrentAboveThresholdA3
OBJECT-IDENTITY
The output current on input source 1 phase 3 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.6.10.3current
tlpAtsAlarmCurrentAboveThresholdB1
OBJECT-IDENTITY
The output current on input source 2 phase 1 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.6.10.4current
tlpAtsAlarmCurrentAboveThresholdB2
OBJECT-IDENTITY
The output current on input source 2 phase 2 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.6.10.5current
tlpAtsAlarmCurrentAboveThresholdB3
OBJECT-IDENTITY
The output current on input source 2 phase 3 exceeds load limits.
1.3.6.1.4.1.850.1.3.3.6.10.6current
tlpAtsAlarmLoadsNotAllOn
OBJECT-IDENTITY
One of more loads are not on.
1.3.6.1.4.1.850.1.3.3.6.11current
tlpAtsAlarmGeneralFault
OBJECT-IDENTITY
A general fault in the ats has been detected.
1.3.6.1.4.1.850.1.3.3.6.12current
tlpAtsAlarmVoltage
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.13
tlpAtsAlarmOverVoltage
OBJECT-IDENTITY
The input voltage is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.13.1current
tlpAtsAlarmSource1OverVoltage
OBJECT-IDENTITY
The voltage on source 1 is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.13.2current
tlpAtsAlarmSource2OverVoltage
OBJECT-IDENTITY
The voltage on source 2 is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.13.3current
tlpAtsAlarmFrequency
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.14
tlpAtsAlarmSource1InvalidFrequency
OBJECT-IDENTITY
The voltage on source 1 is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.14.1current
tlpAtsAlarmSource2InvalidFrequency
OBJECT-IDENTITY
The voltage on source 2 is out of tolerance.
1.3.6.1.4.1.850.1.3.3.6.14.2current
tlpAtsAlarmLoadLevelBelowThreshold
OBJECT-IDENTITY
The load level is below the designated threshold.
1.3.6.1.4.1.850.1.3.3.6.15current
tlpAtsAlarmCurrentBelowThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.6.16
tlpAtsAlarmCurrentBelowThresholdA1
OBJECT-IDENTITY
The output current on input source 1 phase 1 below load limits.
1.3.6.1.4.1.850.1.3.3.6.16.1current
tlpAtsAlarmCurrentBelowThresholdA2
OBJECT-IDENTITY
The output current on input source 1 phase 2 below load limits.
1.3.6.1.4.1.850.1.3.3.6.16.2current
tlpAtsAlarmCurrentBelowThresholdA3
OBJECT-IDENTITY
The output current on input source 1 phase 3 below load limits.
1.3.6.1.4.1.850.1.3.3.6.16.3current
tlpAtsAlarmCurrentBelowThresholdB1
OBJECT-IDENTITY
The output current on input source 2 phase 1 below load limits.
1.3.6.1.4.1.850.1.3.3.6.16.4current
tlpAtsAlarmCurrentBelowThresholdB2
OBJECT-IDENTITY
The output current on input source 2 phase 2 below load limits.
1.3.6.1.4.1.850.1.3.3.6.16.5current
tlpAtsAlarmCurrentBelowThresholdB3
OBJECT-IDENTITY
The output current on input source 2 phase 3 below load limits.
1.3.6.1.4.1.850.1.3.3.6.16.6current
tlpCoolingAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.7
tlpCoolingAlarmSupplyAirSensorFault
OBJECT-IDENTITY
The supply air sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.1current
tlpCoolingAlarmReturnAirSensorFault
OBJECT-IDENTITY
The return air sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.2current
tlpCoolingAlarmCondenserInletAirSensorFault
OBJECT-IDENTITY
The condenser inlet air sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.3current
tlpCoolingAlarmCondenserOutletAirSensorFault
OBJECT-IDENTITY
The condenser outlet air sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.4current
tlpCoolingAlarmSuctionTemperatureSensorFault
OBJECT-IDENTITY
The suction temperature sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.5current
tlpCoolingAlarmEvaporatorTemperatureSensorFault
OBJECT-IDENTITY
The evaporator temperature sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.6current
tlpCoolingAlarmAirFilterClogged
OBJECT-IDENTITY
The air filter is clogged.
1.3.6.1.4.1.850.1.3.3.7.7current
tlpCoolingAlarmAirFilterRunHoursViolation
OBJECT-IDENTITY
The air filter run hours was violated.
1.3.6.1.4.1.850.1.3.3.7.8current
tlpCoolingAlarmSuctionPressureSensorFault
OBJECT-IDENTITY
The suction pressure sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.9current
tlpCoolingAlarmInverterCommunicationsFault
OBJECT-IDENTITY
The inverter communications is in fault.
1.3.6.1.4.1.850.1.3.3.7.10current
tlpCoolingAlarmRemoteShutdownViaInputContact
OBJECT-IDENTITY
A remote shutdown was triggerd by an input contact.
1.3.6.1.4.1.850.1.3.3.7.11current
tlpCoolingAlarmCondensatePumpFault
OBJECT-IDENTITY
The condensate pump is in fault.
1.3.6.1.4.1.850.1.3.3.7.12current
tlpCoolingAlarmLowRefrigerantStartupFault
OBJECT-IDENTITY
The low refrigerant startup is in fault.
1.3.6.1.4.1.850.1.3.3.7.13current
tlpCoolingAlarmCondenserFanFault
OBJECT-IDENTITY
The condenser fan is in fault.
1.3.6.1.4.1.850.1.3.3.7.14current
tlpCoolingAlarmCondenserFailure
OBJECT-IDENTITY
The condenser has failed.
1.3.6.1.4.1.850.1.3.3.7.15current
tlpCoolingAlarmEvaporatorCoolingFailure
OBJECT-IDENTITY
The evaporator cooling is in fault.
1.3.6.1.4.1.850.1.3.3.7.16current
tlpCoolingAlarmReturnAirTempHigh
OBJECT-IDENTITY
The return air temperature is high.
1.3.6.1.4.1.850.1.3.3.7.17current
tlpCoolingAlarmSupplyAirTempHigh
OBJECT-IDENTITY
The supply air temperature is high.
1.3.6.1.4.1.850.1.3.3.7.18current
tlpCoolingAlarmEvaporatorFailure
OBJECT-IDENTITY
The evaporator has failed.
1.3.6.1.4.1.850.1.3.3.7.19current
tlpCoolingAlarmEvaporatorFreezeUp
OBJECT-IDENTITY
The evaporator is frozen.
1.3.6.1.4.1.850.1.3.3.7.20current
tlpCoolingAlarmDischargePressureHigh
OBJECT-IDENTITY
The discharge pressure is high.
1.3.6.1.4.1.850.1.3.3.7.21current
tlpCoolingAlarmPressureGaugeFailure
OBJECT-IDENTITY
The pressure gauge has failed.
1.3.6.1.4.1.850.1.3.3.7.22current
tlpCoolingAlarmDischargePressurePersistentHigh
OBJECT-IDENTITY
The discharge pressure is persistently high.
1.3.6.1.4.1.850.1.3.3.7.23current
tlpCoolingAlarmSuctionPressureLowStartFailure
OBJECT-IDENTITY
Cannot start due to low suction pressure.
1.3.6.1.4.1.850.1.3.3.7.24current
tlpCoolingAlarmSuctionPressureLow
OBJECT-IDENTITY
The suction pressure is low.
1.3.6.1.4.1.850.1.3.3.7.25current
tlpCoolingAlarmSuctionPressurePersistentLow
OBJECT-IDENTITY
The suction pressure is persistently low.
1.3.6.1.4.1.850.1.3.3.7.26current
tlpCoolingAlarmStartupLinePressureImbalance
OBJECT-IDENTITY
The startup line pressure is in imbalance.
1.3.6.1.4.1.850.1.3.3.7.27current
tlpCoolingAlarmCompressorFailure
OBJECT-IDENTITY
The compressor has failed.
1.3.6.1.4.1.850.1.3.3.7.28current
tlpCoolingAlarmCurrentLimit
OBJECT-IDENTITY
The current is out of range.
1.3.6.1.4.1.850.1.3.3.7.29current
tlpCoolingAlarmWaterLeak
OBJECT-IDENTITY
Water is leaking.
1.3.6.1.4.1.850.1.3.3.7.30current
tlpCoolingAlarmFanUnderCurrent
OBJECT-IDENTITY
The fan is under current.
1.3.6.1.4.1.850.1.3.3.7.31current
tlpCoolingAlarmFanOverCurrent
OBJECT-IDENTITY
The fan is over current.
1.3.6.1.4.1.850.1.3.3.7.32current
tlpCoolingAlarmDischargePressureSensorFault
OBJECT-IDENTITY
The discharge pressure sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.33current
tlpCoolingAlarmWaterFull
OBJECT-IDENTITY
Water is Full.
1.3.6.1.4.1.850.1.3.3.7.34current
tlpCoolingAlarmAutoCoolingOn
OBJECT-IDENTITY
Automatic cooling was activated to lower the temperature below the remote set point.
1.3.6.1.4.1.850.1.3.3.7.35current
tlpCoolingAlarmPowerButtonPressed
OBJECT-IDENTITY
Power button was pressed on the front panel.
1.3.6.1.4.1.850.1.3.3.7.36current
tlpCoolingAlarmDisconnectedFromDevice
OBJECT-IDENTITY
The device communications is disconnected.
1.3.6.1.4.1.850.1.3.3.7.37current
tlpCoolingAlarmAmbientTemperatureSensorFault
OBJECT-IDENTITY
Ambient temperature sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.38current
tlpCoolingAlarmRemoteTemperatureSensorFault
OBJECT-IDENTITY
Remote temperature sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.39current
tlpCoolingAlarmLowPressureSensorFault
OBJECT-IDENTITY
Low pressure sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.40current
tlpCoolingAlarmHighPressureSensorFault
OBJECT-IDENTITY
High pressure sensor is in fault.
1.3.6.1.4.1.850.1.3.3.7.41current
tlpCoolingAlarmSentrytimerTimeout
OBJECT-IDENTITY
Sentry timer time out.
1.3.6.1.4.1.850.1.3.3.7.42current
tlpKvmAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.8
tlpRackTrackAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.9
tlpSwitchAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.3.10
tlpAlarmControl
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.3.4
tlpAlarmControlTable
OBJECT-TYPE
A list of alarm conditions supported for each device managed by this agent. This table contains zero, one, or many rows depending upon the number of available alarms managed by each device.
1.3.6.1.4.1.850.1.3.4.1not-accessiblecurrent
tlpAlarmControlEntry
OBJECT-TYPE
An entry containing details for a particular alarm condition.
1.3.6.1.4.1.850.1.3.4.1.1not-accessiblecurrent
tlpAlarmControlIndex
OBJECT-TYPE
The table row index for this alarm control entry for this device. The index of any one row represents the index of the alarm entry within the agent system. As such, the index values for any one device is not guaranteed to start with 1 or be numerically sequential.
1.3.6.1.4.1.850.1.3.4.1.1.1Unsigned32read-onlycurrent
tlpAlarmControlDescr
OBJECT-TYPE
A reference of the alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active. This will be the same object description of an alarm when in alarm as referenced by tlpAlarmDescr.
1.3.6.1.4.1.850.1.3.4.1.1.2OBJECT IDENTIFIERread-onlycurrent
tlpAlarmControlDetail
OBJECT-TYPE
A textual description of the alarm condition. This will be the same textual description of an alarm when in alarm as referenced by tlpAlarmDetail.
1.3.6.1.4.1.850.1.3.4.1.1.3DisplayStringread-onlycurrent
tlpAlarmControlSeverity
OBJECT-TYPE
The severity of this alarm, which can be configured as desired for each alarm condition. This will be the same severity used when in alarm as referenced by tlpAlarmType.
1.3.6.1.4.1.850.1.3.4.1.1.4INTEGER {critical(1), warning(2), info(3)}read-writecurrent
tlpNotify
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4
tlpNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.1
tlpNotificationsEvent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2
tlpNotificationsAgent
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.1
tlpNotificationsDevice
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.2
tlpNotificationsUps
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.3
tlpNotificationsPdu
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.4
tlpNotificationsEnvirosense
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.5
tlpNotificationsAts
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.6
tlpNotificationsCooling
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.7
tlpNotificationsKvm
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.8
tlpNotificationsRackTrack
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.9
tlpNotificationsSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.2.10
tlpNotificationsEventParameters
OBJECT-IDENTITY
1.3.6.1.4.1.850.1.4.3
tlpNotifyEventTableRef
OBJECT-TYPE
This value references the OID of a table object applicable to the event condition. This, in conjunction with the table row as defined by tlpAlarmTableRowRef, specifies the object/row within this table to which the event condition applies. Refer to tlpAlarmTableRef for more information.
1.3.6.1.4.1.850.1.4.3.1OBJECT IDENTIFIERread-onlycurrent
tlpNotifyEventTableRowRef
OBJECT-TYPE
This value is used in conjunction with tlpNotifyEventTableRef to define the object associated with this event condition. See the description of tlpNotifyEventTableRef for more information.
1.3.6.1.4.1.850.1.4.3.2OBJECT IDENTIFIERread-onlycurrent

Notifications

NameOIDStatus
tlpNotificationsAlarmEntryAdded
NOTIFICATION-TYPE
This notification is sent each time an alarm condition is inserted into the device alarm table, tlpAlarmTable.
1.3.6.1.4.1.850.1.4.1.1current
tlpNotificationsAlarmEntryRemoved
NOTIFICATION-TYPE
This notification is sent each time an alarm condition is removed from the device alarm table, tlpAlarmTable.
1.3.6.1.4.1.850.1.4.1.2current
tlpNotifySystemStartup
NOTIFICATION-TYPE
Used to inform another entity of an agent's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
1.3.6.1.4.1.850.1.4.1.3current
tlpNotifySystemShutdown
NOTIFICATION-TYPE
Used to inform another entity of an agent's shutdown. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
1.3.6.1.4.1.850.1.4.1.4current
tlpNotifySystemUpdate
NOTIFICATION-TYPE
Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
1.3.6.1.4.1.850.1.4.1.5current
tlpNotifyTest
NOTIFICATION-TYPE
Used when performing a test of the system or an alert notification contact. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC]
1.3.6.1.4.1.850.1.4.1.6current
tlpNotificationsDeviceInternalFirmwareFault
NOTIFICATION-TYPE
This notification is sent when the device experiences an internal firmware failure.
1.3.6.1.4.1.850.1.4.2.2.1current
tlpNotificationsDeviceInternalHardwareFault
NOTIFICATION-TYPE
This notification is sent when the device experiences an internal hardware failure.
1.3.6.1.4.1.850.1.4.2.2.2current
tlpNotificationsDeviceConfigurationChange
NOTIFICATION-TYPE
This notification is sent when the device configuration changes.
1.3.6.1.4.1.850.1.4.2.2.3current
tlpNotificationsDeviceFirmwareUpdate
NOTIFICATION-TYPE
This notification is sent when the device firmware is updated.
1.3.6.1.4.1.850.1.4.2.2.4current
tlpNotificationsDeviceMicrocontrollerReset
NOTIFICATION-TYPE
This notification is sent when the device microcontroller resets.
1.3.6.1.4.1.850.1.4.2.2.5current
tlpNotificationsDeviceSystemInformation
NOTIFICATION-TYPE
This notification is sent when the device sysytem information changes.
1.3.6.1.4.1.850.1.4.2.2.6current
tlpNotificationsDeviceNvrChecksumMismatch
NOTIFICATION-TYPE
This notification is sent when the NVR is corrupted.
1.3.6.1.4.1.850.1.4.2.2.7current
tlpNotificationsDeviceUsbCommunicationsEstablished
NOTIFICATION-TYPE
This notification is sent when the device USB communications is established.
1.3.6.1.4.1.850.1.4.2.2.8current
tlpNotificationsDeviceUsbCommunicationsLost
NOTIFICATION-TYPE
This notification is sent when the device USB communications is lost.
1.3.6.1.4.1.850.1.4.2.2.9current
tlpNotificationsDevicePowerSupplyShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to a power supply fault.
1.3.6.1.4.1.850.1.4.2.2.10current
tlpNotificationsDeviceOverLoadShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to an over load fault.
1.3.6.1.4.1.850.1.4.2.2.11current
tlpNotificationsDeviceCurrentLimitShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to a current limit fault.
1.3.6.1.4.1.850.1.4.2.2.12current
tlpNotificationsDeviceOverTemperatureShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to an over temperature fault.
1.3.6.1.4.1.850.1.4.2.2.13current
tlpNotificationsDeviceModeTransitionTimeout
NOTIFICATION-TYPE
This notification is sent when the device timed out transitioning to a mode.
1.3.6.1.4.1.850.1.4.2.2.14current
tlpNotificationsDeviceFailedModeTransitionToIdle
NOTIFICATION-TYPE
This notification is sent when the device failed a transition to idle mode.
1.3.6.1.4.1.850.1.4.2.2.15current
tlpNotificationsDeviceInternalCommunicationsLost
NOTIFICATION-TYPE
This notification is sent when the device lost internal communications.
1.3.6.1.4.1.850.1.4.2.2.16current
tlpNotificationsDeviceAcknowledgeFaults
NOTIFICATION-TYPE
This notification is sent when device faults are acknowledged.
1.3.6.1.4.1.850.1.4.2.2.17current
tlpNotificationsDeviceTransferToReboot
NOTIFICATION-TYPE
This notification is sent when a device reboot occurred.
1.3.6.1.4.1.850.1.4.2.2.18current
tlpNotificationsDeviceTransferToWatchdogReboot
NOTIFICATION-TYPE
This notification is sent when a device reboot occurred due to a watchdog fault.
1.3.6.1.4.1.850.1.4.2.2.19current
tlpNotificationsDeviceTransferToLatchedIdle
NOTIFICATION-TYPE
This notification is sent when the device transferred to latched idle mode.
1.3.6.1.4.1.850.1.4.2.2.20current
tlpNotificationsDeviceTransferToLatchedStandby
NOTIFICATION-TYPE
This notification is sent when the device transferred to latched standby mode.
1.3.6.1.4.1.850.1.4.2.2.21current
tlpNotificationsDeviceTransferToLatchedLine
NOTIFICATION-TYPE
This notification is sent when the device transferred to latched line mode.
1.3.6.1.4.1.850.1.4.2.2.22current
tlpNotificationsDeviceFailSafeClockMonitorEngaged
NOTIFICATION-TYPE
This notification is sent when the fail safe clock monitor is engaged.
1.3.6.1.4.1.850.1.4.2.2.23current
tlpNotificationsDeviceTransferToIdle
NOTIFICATION-TYPE
This notification is sent when the device transferred to idle mode.
1.3.6.1.4.1.850.1.4.2.2.24current
tlpNotificationsDeviceVoutUnderVoltageShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to a vout under voltage fault.
1.3.6.1.4.1.850.1.4.2.2.25current
tlpNotificationsDeviceVoutOverVoltageShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to a vout over voltage fault.
1.3.6.1.4.1.850.1.4.2.2.26current
tlpNotificationsDeviceUnhandledFault
NOTIFICATION-TYPE
This notification is sent when the device reports an unhandled fault.
1.3.6.1.4.1.850.1.4.2.2.27current
tlpNotificationsUpsBatteryLowVoltageShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to a low battery voltage fault.
1.3.6.1.4.1.850.1.4.2.3.1current
tlpNotificationsUpsBatteryLowPercentageShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to a low battery percentage fault.
1.3.6.1.4.1.850.1.4.2.3.2current
tlpNotificationsUpsBatteryOverVoltageShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to a battery over voltage fault.
1.3.6.1.4.1.850.1.4.2.3.3current
tlpNotificationsUpsBatteryOverCurrentShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to a battery over current fault.
1.3.6.1.4.1.850.1.4.2.3.4current
tlpNotificationsUpsBatteryUnknownTypeShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to an unknown battery type fault.
1.3.6.1.4.1.850.1.4.2.3.5current
tlpNotificationsUpsBatteryConfigurationMismatch
NOTIFICATION-TYPE
This notification is sent when the ups battery configuration is mismatched.
1.3.6.1.4.1.850.1.4.2.3.6current
tlpNotificationsUpsBatteryUnderVoltageShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to a battery under voltage fault.
1.3.6.1.4.1.850.1.4.2.3.7current
tlpNotificationsUpsSlaBatteryOverTemperatureShutdown
NOTIFICATION-TYPE
This notification is sent when the ups reports a shutdown occurred due to an SLA battery over temperature fault.
1.3.6.1.4.1.850.1.4.2.3.8current
tlpNotificationsUpsBatteryInstallation
NOTIFICATION-TYPE
This notification is sent when a battery installation occurs.
1.3.6.1.4.1.850.1.4.2.3.9current
tlpNotificationsUpsChargerBulkToAcceptance
NOTIFICATION-TYPE
This notification is sent when ups battery charging.
1.3.6.1.4.1.850.1.4.2.3.10current
tlpNotificationsUpsChargerAcceptanceToFloat
NOTIFICATION-TYPE
This notification is sent when ups battery fully charged.
1.3.6.1.4.1.850.1.4.2.3.11current
tlpNotificationsUpsChargerFloatToBulk
NOTIFICATION-TYPE
This notification is sent when ups battery not fully charged.
1.3.6.1.4.1.850.1.4.2.3.12current
tlpNotificationsUpsTransferToSelftest
NOTIFICATION-TYPE
This notification is sent when a self test is initiated.
1.3.6.1.4.1.850.1.4.2.3.13current
tlpNotificationsUpsTransferToEconomy
NOTIFICATION-TYPE
This notification is sent when the device transferred to economy mode.
1.3.6.1.4.1.850.1.4.2.3.14current
tlpNotificationsUpsLineConnectRelayFaultShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to line connect relay fault.
1.3.6.1.4.1.850.1.4.2.3.15current
tlpNotificationsUpsTransferToFaultBypass
NOTIFICATION-TYPE
This notification is sent when the device transferred to fault bypass mode.
1.3.6.1.4.1.850.1.4.2.3.16current
tlpNotificationsUpsBypassPowerDistributionModuleDisconnected
NOTIFICATION-TYPE
This notification is sent when bypass power distribution module is disconnected.
1.3.6.1.4.1.850.1.4.2.3.17current
tlpNotificationsUpsManualBypassActivatedFromUnsupportedMode
NOTIFICATION-TYPE
This notification is sent when manual bypass activated from an unsupported UPS mode.
1.3.6.1.4.1.850.1.4.2.3.18current
tlpNotificationsUpsOnBatteryTimeoutShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to on battery timeout.
1.3.6.1.4.1.850.1.4.2.3.19current
tlpNotificationsUpsLowBatteryPercentageShutdown
NOTIFICATION-TYPE
This notification is sent when the device reports a shutdown occurred due to low battery percentage.
1.3.6.1.4.1.850.1.4.2.3.20current
tlpNotificationsAtsSource1NotAvailable
NOTIFICATION-TYPE
This notification is sent when input on source one is not available. For atss with the designation of primary and secondary, this notification denotes input on the primary source is not available.
1.3.6.1.4.1.850.1.4.2.6.1current
tlpNotificationsAtsSource2NotAvailable
NOTIFICATION-TYPE
This notification is sent when input on source two is not available. For atss with the designation of primary and secondary, this notification denotes input on the secondary source is not available.
1.3.6.1.4.1.850.1.4.2.6.2current
tlpNotificationsAtsLockdownToSource1
NOTIFICATION-TYPE
This notification is sent upon a transfer circuit fault causing the device to be locked on source 1.
1.3.6.1.4.1.850.1.4.2.6.3current
tlpNotificationsAtsLockdownToSource2
NOTIFICATION-TYPE
This notification is sent upon a transfer circuit fault causing the device to be locked on source 2.
1.3.6.1.4.1.850.1.4.2.6.4current
tlpNotificationsAtsSource1Available
NOTIFICATION-TYPE
This notification is sent when source 1 is available and ready for use.
1.3.6.1.4.1.850.1.4.2.6.5current
tlpNotificationsAtsSource2Available
NOTIFICATION-TYPE
This notification is sent when source 2 is available and ready for use.
1.3.6.1.4.1.850.1.4.2.6.6current
tlpNotificationsAtsSource1Brownout
NOTIFICATION-TYPE
This notification is sent when a brownout condition occurred on source 1.
1.3.6.1.4.1.850.1.4.2.6.7current
tlpNotificationsAtsSource2Brownout
NOTIFICATION-TYPE
This notification is sent when a brownout condition occurred on source 2.
1.3.6.1.4.1.850.1.4.2.6.8current
tlpNotificationsAtsSource1VoltageDrop
NOTIFICATION-TYPE
This notification is sent when the voltage on source 1 drops below a usable state.
1.3.6.1.4.1.850.1.4.2.6.9current
tlpNotificationsAtsSource2VoltageDrop
NOTIFICATION-TYPE
This notification is sent when the voltage on source 2 drops below a usable state.
1.3.6.1.4.1.850.1.4.2.6.10current
tlpNotificationsAtsTimedReturnToSource1
NOTIFICATION-TYPE
This notification is sent when the active input source returns to source 1 from source 2 after a delay time expires.
1.3.6.1.4.1.850.1.4.2.6.11current
tlpNotificationsAtsTimedReturnToSource2
NOTIFICATION-TYPE
This notification is sent when the active input source returns to source 2 from source 1 after a delay time expires.
1.3.6.1.4.1.850.1.4.2.6.12current
tlpNotificationsAtsTransferToSource1
NOTIFICATION-TYPE
This notification is sent when the active input source transfers from source 2 to source 1.
1.3.6.1.4.1.850.1.4.2.6.13current
tlpNotificationsAtsTransferToSource2
NOTIFICATION-TYPE
This notification is sent when the active input source transfers from source 1 to source 2.
1.3.6.1.4.1.850.1.4.2.6.14current