TOKENRING-MIB
- Registered at
- 1.3.6.1.2.1.10.9
- Last updated
- 1994-10-23 11:50
- Organization
- IETF Interfaces MIB Working Group
- Namespace
- standard
- Source file
TOKENRING-MIB- Digest
sha256:52671dea1836422553f20b1375d45b70272d23d6db27136da4c154a8b8d0d8a5
Description
The MIB module for IEEE Token Ring entities.
Contact
Keith McCloghrie Postal: cisco Systems, Inc. 170 West Tasman Drive, San Jose, CA 95134-1706 US Phone: +1 408 526 5260 EMail: kzm@cisco.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission |
| SNMPv2-TC | DisplayString, MacAddress, TEXTUAL-CONVENTION, TimeStamp |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC TOKENRING-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| dot5Table OBJECT-TYPE This table contains Token Ring interface parameters and state variables, one entry per 802.5 interface. | 1.3.6.1.2.1.10.9.1 | not-accessible | current | |
| dot5Entry OBJECT-TYPE A list of Token Ring status and parameter values for an 802.5 interface. | 1.3.6.1.2.1.10.9.1.1 | not-accessible | current | |
| dot5IfIndex OBJECT-TYPE The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in MIB-II for the same interface. | 1.3.6.1.2.1.10.9.1.1.1 | Integer32 | read-only | current |
| dot5Commands OBJECT-TYPE When this object is set to the value of open(2), the station should go into the open state. The progress and success of the open is given by the values of the objects dot5RingState and dot5RingOpenStatus. When this object is set to the value of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side affects are dependent on the hardware chip set. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of noop(1) has no effect. When read, this object always has a value of noop(1). The open(2) and close(4) values correspond to the up(1) and down(2) values of MIB-II's ifAdminStatus and ifOperStatus, i.e., the setting of ifAdminStatus and dot5Commands affects the values of both dot5Commands and ifOperStatus. | 1.3.6.1.2.1.10.9.1.1.2 | INTEGER {noop(1), open(2), reset(3), close(4)} | read-write | current |
| dot5RingStatus OBJECT-TYPE The current interface status which can be used to diagnose fluctuating problems that can occur on token rings, after a station has successfully been added to the ring. Before an open is completed, this object has the value for the 'no status' condition. The dot5RingState and dot5RingOpenStatus objects provide for debugging problems when the station can not even enter the ring. The object's value is a sum of values, one for each currently applicable condition. The following values are defined for various conditions: 0 = No Problems detected 32 = Ring Recovery 64 = Single Station 256 = Remove Received 512 = reserved 1024 = Auto-Removal Error 2048 = Lobe Wire Fault 4096 = Transmit Beacon 8192 = Soft Error 16384 = Hard Error 32768 = Signal Loss 131072 = no status, open not completed. | 1.3.6.1.2.1.10.9.1.1.3 | INTEGER (0..262143) | read-only | current |
| dot5RingState OBJECT-TYPE The current interface state with respect to entering or leaving the ring. | 1.3.6.1.2.1.10.9.1.1.4 | INTEGER {opened(1), closed(2), opening(3), closing(4), openFailure(5), ringFailure(6)} | read-only | current |
| dot5RingOpenStatus OBJECT-TYPE This object indicates the success, or the reason for failure, of the station's most recent attempt to enter the ring. | 1.3.6.1.2.1.10.9.1.1.5 | INTEGER {noOpen(1), badParam(2), lobeFailed(3), signalLoss(4), insertionTimeout(5), ringFailed(6), beaconing(7), duplicateMAC(8), requestFailed(9), removeReceived(10), open(11)} | read-only | current |
| dot5RingSpeed OBJECT-TYPE The ring-speed at the next insertion into the ring. Note that this may or may not be different to the current ring-speed which is given by MIB-II's ifSpeed. For interfaces which do not support changing ring-speed, dot5RingSpeed can only be set to its current value. When dot5RingSpeed has the value unknown(1), the ring's actual ring-speed is to be used. | 1.3.6.1.2.1.10.9.1.1.6 | INTEGER {unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4)} | read-write | current |
| dot5UpStream OBJECT-TYPE The MAC-address of the up stream neighbor station in the ring. | 1.3.6.1.2.1.10.9.1.1.7 | MacAddress | read-only | current |
| dot5ActMonParticipate OBJECT-TYPE If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object does not take effect until the next Active Monitor election, and might not take effect until the next time the interface is opened. | 1.3.6.1.2.1.10.9.1.1.8 | INTEGER {true(1), false(2)} | read-write | current |
| dot5Functional OBJECT-TYPE The bit mask of all Token Ring functional addresses for which this interface will accept frames. | 1.3.6.1.2.1.10.9.1.1.9 | MacAddress | read-write | current |
| dot5LastBeaconSent OBJECT-TYPE The value of MIB-II's sysUpTime object at which the local system last transmitted a Beacon frame on this interface. | 1.3.6.1.2.1.10.9.1.1.10 | TimeStamp | read-only | current |
| dot5StatsTable OBJECT-TYPE A table containing Token Ring statistics, one entry per 802.5 interface. All the statistics are defined using the syntax Counter32 as 32-bit wrap around counters. Thus, if an interface's hardware maintains these statistics in 16-bit counters, then the agent must read the hardware's counters frequently enough to prevent loss of significance, in order to maintain 32-bit counters in software. | 1.3.6.1.2.1.10.9.2 | not-accessible | current | |
| dot5StatsEntry OBJECT-TYPE An entry contains the 802.5 statistics for a particular interface. | 1.3.6.1.2.1.10.9.2.1 | not-accessible | current | |
| dot5StatsIfIndex OBJECT-TYPE The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as MIB-II's ifIndex object for the same interface. | 1.3.6.1.2.1.10.9.2.1.1 | Integer32 | read-only | current |
| dot5StatsLineErrors OBJECT-TYPE This counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame. | 1.3.6.1.2.1.10.9.2.1.2 | Counter32 | read-only | current |
| dot5StatsBurstErrors OBJECT-TYPE This counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error). | 1.3.6.1.2.1.10.9.2.1.3 | Counter32 | read-only | current |
| dot5StatsACErrors OBJECT-TYPE This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly. | 1.3.6.1.2.1.10.9.2.1.4 | Counter32 | read-only | current |
| dot5StatsAbortTransErrors OBJECT-TYPE This counter is incremented when a station transmits an abort delimiter while transmitting. | 1.3.6.1.2.1.10.9.2.1.5 | Counter32 | read-only | current |
| dot5StatsInternalErrors OBJECT-TYPE This counter is incremented when a station recognizes an internal error. | 1.3.6.1.2.1.10.9.2.1.6 | Counter32 | read-only | current |
| dot5StatsLostFrameErrors OBJECT-TYPE This counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off. | 1.3.6.1.2.1.10.9.2.1.7 | Counter32 | read-only | current |
| dot5StatsReceiveCongestions OBJECT-TYPE This counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station is congested. | 1.3.6.1.2.1.10.9.2.1.8 | Counter32 | read-only | current |
| dot5StatsFrameCopiedErrors OBJECT-TYPE This counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a possible line hit or duplicate address. | 1.3.6.1.2.1.10.9.2.1.9 | Counter32 | read-only | current |
| dot5StatsTokenErrors OBJECT-TYPE This counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted. | 1.3.6.1.2.1.10.9.2.1.10 | Counter32 | read-only | current |
| dot5StatsSoftErrors OBJECT-TYPE The number of Soft Errors the interface has detected. It directly corresponds to the number of Report Error MAC frames that this interface has transmitted. Soft Errors are those which are recoverable by the MAC layer protocols. | 1.3.6.1.2.1.10.9.2.1.11 | Counter32 | read-only | current |
| dot5StatsHardErrors OBJECT-TYPE The number of times this interface has detected an immediately recoverable fatal error. It denotes the number of times this interface is either transmitting or receiving beacon MAC frames. | 1.3.6.1.2.1.10.9.2.1.12 | Counter32 | read-only | current |
| dot5StatsSignalLoss OBJECT-TYPE The number of times this interface has detected the loss of signal condition from the ring. | 1.3.6.1.2.1.10.9.2.1.13 | Counter32 | read-only | current |
| dot5StatsTransmitBeacons OBJECT-TYPE The number of times this interface has transmitted a beacon frame. | 1.3.6.1.2.1.10.9.2.1.14 | Counter32 | read-only | current |
| dot5StatsRecoverys OBJECT-TYPE The number of Claim Token MAC frames received or transmitted after the interface has received a Ring Purge MAC frame. This counter signifies the number of times the ring has been purged and is being recovered back into a normal operating state. | 1.3.6.1.2.1.10.9.2.1.15 | Counter32 | read-only | current |
| dot5StatsLobeWires OBJECT-TYPE The number of times the interface has detected an open or short circuit in the lobe data path. The adapter will be closed and dot5RingState will signify this condition. | 1.3.6.1.2.1.10.9.2.1.16 | Counter32 | read-only | current |
| dot5StatsRemoves OBJECT-TYPE The number of times the interface has received a Remove Ring Station MAC frame request. When this frame is received the interface will enter the close state and dot5RingState will signify this condition. | 1.3.6.1.2.1.10.9.2.1.17 | Counter32 | read-only | current |
| dot5StatsSingles OBJECT-TYPE The number of times the interface has sensed that it is the only station on the ring. This will happen if the interface is the first one up on a ring, or if there is a hardware problem. | 1.3.6.1.2.1.10.9.2.1.18 | Counter32 | read-only | current |
| dot5StatsFreqErrors OBJECT-TYPE The number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that specified by the IEEE 802.5 standard. | 1.3.6.1.2.1.10.9.2.1.19 | Counter32 | read-only | current |
| dot5Tests OBJECT-IDENTITY | 1.3.6.1.2.1.10.9.3 | |||
| dot5TestInsertFunc OBJECT-IDENTITY Invoking this test causes the station to test the insert ring logic of the hardware if the station's lobe media cable is connected to a wiring concentrator. Note that this command inserts the station into the network, and thus, could cause problems if the station is connected to a operational network. | 1.3.6.1.2.1.10.9.3.1 | current | ||
| dot5TestFullDuplexLoopBack OBJECT-IDENTITY Invoking this test on a 802.5 interface causes the interface to check the path from memory through the chip set's internal logic and back to memory, thus checking the proper functioning of the system's interface to the chip set. | 1.3.6.1.2.1.10.9.3.2 | current | ||
| dot5ChipSets OBJECT-IDENTITY | 1.3.6.1.2.1.10.9.4 | |||
| dot5ChipSetIBM16 OBJECT-IDENTITY IBM's 16/4 Mbs chip set. | 1.3.6.1.2.1.10.9.4.1 | current | ||
| dot5ChipSetTItms380 OBJECT-IDENTITY Texas Instruments' TMS 380 4Mbs chip-set | 1.3.6.1.2.1.10.9.4.2 | current | ||
| dot5ChipSetTItms380c16 OBJECT-IDENTITY Texas Instruments' TMS 380C16 16/4 Mbs chip-set | 1.3.6.1.2.1.10.9.4.3 | current | ||
| dot5TimerTable OBJECT-TYPE This table contains Token Ring interface timer values, one entry per 802.5 interface. | 1.3.6.1.2.1.10.9.5 | not-accessible | obsolete | |
| dot5TimerEntry OBJECT-TYPE A list of Token Ring timer values for an 802.5 interface. | 1.3.6.1.2.1.10.9.5.1 | not-accessible | obsolete | |
| dot5TimerIfIndex OBJECT-TYPE The value of this object identifies the 802.5 interface for which this entry contains timer values. The value of this object for a particular interface has the same value as MIB-II's ifIndex object for the same interface. | 1.3.6.1.2.1.10.9.5.1.1 | Integer32 | read-only | obsolete |
| dot5TimerReturnRepeat OBJECT-TYPE The time-out value used to ensure the interface will return to Repeat State, in units of 100 micro-seconds. The value should be greater than the maximum ring latency. | 1.3.6.1.2.1.10.9.5.1.2 | Integer32 | read-only | obsolete |
| dot5TimerHolding OBJECT-TYPE Maximum period of time a station is permitted to transmit frames after capturing a token, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.3 | Integer32 | read-only | obsolete |
| dot5TimerQueuePDU OBJECT-TYPE The time-out value for enqueuing of an SMP PDU after reception of an AMP or SMP frame in which the A and C bits were equal to 0, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.4 | Integer32 | read-only | obsolete |
| dot5TimerValidTransmit OBJECT-TYPE The time-out value used by the active monitor to detect the absence of valid transmissions, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.5 | Integer32 | read-only | obsolete |
| dot5TimerNoToken OBJECT-TYPE The time-out value used to recover from various-related error situations. If N is the maximum number of stations on the ring, the value of this timer is normally: dot5TimerReturnRepeat + N*dot5TimerHolding. | 1.3.6.1.2.1.10.9.5.1.6 | Integer32 | read-only | obsolete |
| dot5TimerActiveMon OBJECT-TYPE The time-out value used by the active monitor to stimulate the enqueuing of an AMP PDU for transmission, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.7 | Integer32 | read-only | obsolete |
| dot5TimerStandbyMon OBJECT-TYPE The time-out value used by the stand-by monitors to ensure that there is an active monitor on the ring and to detect a continuous stream of tokens, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.8 | Integer32 | read-only | obsolete |
| dot5TimerErrorReport OBJECT-TYPE The time-out value which determines how often a station shall send a Report Error MAC frame to report its error counters, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.9 | Integer32 | read-only | obsolete |
| dot5TimerBeaconTransmit OBJECT-TYPE The time-out value which determines how long a station shall remain in the state of transmitting Beacon frames before entering the Bypass state, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.10 | Integer32 | read-only | obsolete |
| dot5TimerBeaconReceive OBJECT-TYPE The time-out value which determines how long a station shall receive Beacon frames from its downstream neighbor before entering the Bypass state, in units of 100 micro-seconds. | 1.3.6.1.2.1.10.9.5.1.11 | Integer32 | read-only | obsolete |
| dot5Conformance OBJECT-IDENTITY | 1.3.6.1.2.1.10.9.6 | |||
| dot5Groups OBJECT-IDENTITY | 1.3.6.1.2.1.10.9.6.1 | |||
| dot5Compliances OBJECT-IDENTITY | 1.3.6.1.2.1.10.9.6.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| dot5StateGroup OBJECT-GROUP A collection of objects providing state information and parameters for IEEE 802.5 interfaces. | 1.3.6.1.2.1.10.9.6.1.1 | current |
| dot5StatsGroup OBJECT-GROUP A collection of objects providing statistics for IEEE 802.5 interfaces. | 1.3.6.1.2.1.10.9.6.1.2 | current |
| dot5Compliance MODULE-COMPLIANCE The compliance statement for SNMPv2 entities which implement the IEEE 802.5 MIB. | 1.3.6.1.2.1.10.9.6.2.1 | current |