MIBs Depot

THALES-ESECURITY-PAYSHIELD-MIB

Registered at
1.3.6.1.4.1.4096
Last updated
2021-12-25 08:10
Organization
Thales eSecurity
Revisions
2021-12-25 08:10, 2019-02-26 08:10, 2019-02-26 08:10, 2018-11-12 08:10
Namespace
thales
Source file
THALES-ESECURITY-PAYSHIELD-MIB
Digest
sha256:23ba2bd5d7fe6d57acdcd98b3103d41aa73ae85c6c0d97440bfc40e69c935381

Description

Added new objects payShieldLogsErrorlogMaxLength, payShieldLogsAuditlogMaxLength, payshieldHostConnectionEthernetLoadCount, payShieldSettingsHashSecuritySetting, payShieldSettingsHashGeneralSetting, payShieldSettingsHashConfigureCommand, payShieldSettingsHashAuditSetting and payShieldSettingsHashLMK.

Contact

954 888 6200

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIGauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDateAndTime, DisplayString, MacAddress, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
THALES-ESECURITY-PAYSHIELD-MIB

Objects

NameOIDSyntaxAccessStatus
thalesEsecurity
OBJECT-IDENTITY
1.3.6.1.4.1.4096
thalesEsecurityDevs
OBJECT-IDENTITY
1.3.6.1.4.1.4096.1
payshield
OBJECT-IDENTITY
1.3.6.1.4.1.4096.1.10000
thalesEsecurityMibs
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2
raProductMibs
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2
payShieldUtil
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.1
payShieldUtilLoad
OBJECT-TYPE
Displays the instantaneous load for all host commands processed by the payShield in the previous time period. The load is represented as a percentage of the total [licensed] processing capacity of the device.
1.3.6.1.4.1.4096.2.2.10000.1.1Gauge32 (0..100)read-onlycurrent
payShieldUtilHostCmdVolume
OBJECT-TYPE
Displays the measurement period in seconds and the number of commands in the report followed by a list of all host commands and the number of times each of those host commands that have been processed within the previous measurement period. Note that if a large variety of commands are processed, then this list may be incomplete and will contain the commands that consumed the highest proportion of the device's capacity.
1.3.6.1.4.1.4096.2.2.10000.1.2OCTET STRING (SIZE(0..484))read-onlycurrent
payShieldUtilEnabled
OBJECT-TYPE
True if Utilization turned on
1.3.6.1.4.1.4096.2.2.10000.1.3TruthValueread-onlycurrent
payShieldState
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.2
payShieldStateDevice
OBJECT-TYPE
Indicates the current state of the payShield.
1.3.6.1.4.1.4096.2.2.10000.2.1INTEGER {stateUnavailable(1), stateOnline(2), stateOffline(3), stateSecure(4)}read-onlycurrent
payShieldStateTamper
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.2.2
payShieldStateTamperState
OBJECT-TYPE
Indicates whether the device is currently in a tamper state.
1.3.6.1.4.1.4096.2.2.10000.2.2.1INTEGER {stateUnknown(1), stateOK(2), stateTampered(3)}read-onlycurrent
payShieldStateTamperDate
OBJECT-TYPE
The Date and Time that the last tamper event occurred. A NULL value indicates that the unit has not registered any tamper events.
1.3.6.1.4.1.4096.2.2.10000.2.2.2DateAndTimeread-onlycurrent
payShieldStateTamperCause
OBJECT-TYPE
The cause of the last tamper event
1.3.6.1.4.1.4096.2.2.10000.2.2.3INTEGER {causeUnavailable(1), causeTemperatureOutOfRange(2), causeBatteryLow(3), causeEraseButtonPressed(4), causeSensorProcessorWatchdog(5), causeSensorProcessorRestart(6), causeVoltageOutOfRange(7), causeMotionDetected(8), causeCaseTampered(9), causePowerLoss(10)}read-onlycurrent
payShieldStateFan
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.2.3
payShieldStateFanTable
OBJECT-TYPE
A table that returns the status of fans.
1.3.6.1.4.1.4096.2.2.10000.2.3.1not-accessiblecurrent
payShieldStateFanEntry
OBJECT-TYPE
Row in the fan status table
1.3.6.1.4.1.4096.2.2.10000.2.3.1.1not-accessiblecurrent
payShieldStateFanIndex
OBJECT-TYPE
The index into the fan status table
1.3.6.1.4.1.4096.2.2.10000.2.3.1.1.1Integer32 (1..2)not-accessiblecurrent
payShieldStateFanSerialNum
OBJECT-TYPE
Displays the serial number of this fan unit.
1.3.6.1.4.1.4096.2.2.10000.2.3.1.1.2DisplayStringread-onlycurrent
payShieldStateFanState
OBJECT-TYPE
Indicates the current state of this fan.
1.3.6.1.4.1.4096.2.2.10000.2.3.1.1.3INTEGER {stateOK(1), stateFailure(2), stateNotDetected(3)}read-onlycurrent
payShieldStatePSU
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.2.4
payShieldStatePSUTable
OBJECT-TYPE
A table that returns the status of power supply units.
1.3.6.1.4.1.4096.2.2.10000.2.4.1not-accessiblecurrent
payShieldStatePSUEntry
OBJECT-TYPE
Row in the PSU status table
1.3.6.1.4.1.4096.2.2.10000.2.4.1.1not-accessiblecurrent
payShieldStatePSUIndex
OBJECT-TYPE
The index into the PSU status table
1.3.6.1.4.1.4096.2.2.10000.2.4.1.1.1Integer32 (1..2)not-accessiblecurrent
payShieldStatePSUSerialNum
OBJECT-TYPE
Displays the serial number of this power supply unit.
1.3.6.1.4.1.4096.2.2.10000.2.4.1.1.2DisplayStringread-onlycurrent
payShieldStatePSUState
OBJECT-TYPE
Indicates the current state of this power supply unit.
1.3.6.1.4.1.4096.2.2.10000.2.4.1.1.3INTEGER {stateOK(1), stateFailure(2), stateNotDetected(3)}read-onlycurrent
payShieldStateBattery
OBJECT-TYPE
Indicates the current state of the battery.
1.3.6.1.4.1.4096.2.2.10000.2.5INTEGER {stateOK(1), stateWarning(2), stateFailure(3)}read-onlycurrent
payShieldLmk
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.3
payShieldLmkNumLoaded
OBJECT-TYPE
The number of LMKs currently loaded into the device.
1.3.6.1.4.1.4096.2.2.10000.3.1Integer32read-onlycurrent
payShieldLmkNumTestLmksLoaded
OBJECT-TYPE
Indicates the number of 'test' LMKs loaded (as opposed to production). When the payShield is operating in a live environment, no test LMKs should be loaded and this field should be returned as 0.
1.3.6.1.4.1.4096.2.2.10000.3.2Integer32read-onlycurrent
payShieldLmkNumOldLmksLoaded
OBJECT-TYPE
Indicates the number of old LMKs currently loaded in the payShield. Old LMKs should be stored in the device only as long as they are needed for translation purposes. Once all LMK-protected data has been placed under the control of the new LMK set, then the old LMK set should be deleted.
1.3.6.1.4.1.4096.2.2.10000.3.3Integer32read-onlycurrent
payShieldLmkStatusTable
OBJECT-TYPE
A table that returns the status of all possible LMK sets.
1.3.6.1.4.1.4096.2.2.10000.3.4not-accessiblecurrent
payShieldLmkStatusEntry
OBJECT-TYPE
Row in the LMK Status table
1.3.6.1.4.1.4096.2.2.10000.3.4.1not-accessiblecurrent
payShieldLmkStatusIndex
OBJECT-TYPE
The index into the LMK Status table
1.3.6.1.4.1.4096.2.2.10000.3.4.1.1Integer32 (1..20)not-accessiblecurrent
payShieldLmkStatusLoaded
OBJECT-TYPE
Indicates whether or not an LMK set is currently loaded at this index in the table. Returns TRUE if loaded, else FALSE.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.2TruthValueread-onlycurrent
payShieldLmkStatusAuth
OBJECT-TYPE
Authorized state of this LMK set. A value of TRUE indicates that the LMK is in an authorized state; FALSE indicates that it is not authorized.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.3TruthValueread-onlycurrent
payShieldLmkStatusNumAuthActivities
OBJECT-TYPE
Indicates the number of authorized activities if the payShield is set to Multi-Auth mode. If not in multi-auth mode, returns 0.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.4Integer32read-onlycurrent
payShieldLmkStatusScheme
OBJECT-TYPE
Indicates the scheme of the loaded LMK set (variant, keyblock, or AES).
1.3.6.1.4.1.4096.2.2.10000.3.4.1.5INTEGER {lmkSchemeUnknown(1), lmkSchemeVariant(2), lmkSchemeKeyblock(3), lmkSchemeAES(4)}read-onlycurrent
payShieldLmkStatusAlgorithm
OBJECT-TYPE
Indicates the algorithm used by the LMK set for encryption.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.6INTEGER {lmkAlgorithmUnknown(1), lmkAlgorithm3DES2Key(2), lmkAlgorithm3DES3Key(3), lmkAlgorithmAES256(4)}read-onlycurrent
payShieldLmkStatusLiveTest
OBJECT-TYPE
Indicates the status of the currently loaded LMK set. This will be either 'Live' or 'Test'. Note that test LMKs should not be loaded into a payShield operating in a live customer environment.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.7INTEGER {lmkStatusUnknown(1), lmkStatusLive(2), lmkStatusTest(3)}read-onlycurrent
payShieldLmkStatusComments
OBJECT-TYPE
Textual description of the LMK set loaded. A string of length 0 indicates that no description is stored.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.8OCTET STRING (SIZE(0..41))read-onlycurrent
payShieldLmkStatusCheckDigits
OBJECT-TYPE
Indicates the check digits for an LMK.
1.3.6.1.4.1.4096.2.2.10000.3.4.1.9DisplayStringread-onlycurrent
payShieldComms
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.4
payShieldCommsMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.4.1
payShieldCommsMgmtConsoleState
OBJECT-TYPE
Indicates whether the process to service Console Management requests is currently running. payShieldCommsMgmtConsoleStateUp (1) indicates that it is; all the other states indicate that the console is currently inactive.
1.3.6.1.4.1.4096.2.2.10000.4.1.1INTEGER {consoleUp(1), consoleDown(2), consoleDisabledByGui(3), consoleUnavailable(4)}read-onlycurrent
payShieldCommsMgmtGuiState
OBJECT-TYPE
Indicates whether the process to service GUI requests is currently running. payShieldCommsMgmtGuiStateUp (1) indicates that it is; all the other states indicate that the GUI is currently inactive.
1.3.6.1.4.1.4096.2.2.10000.4.1.2INTEGER {guiUp(1), guiDown(2), guiUnavailable(3)}read-onlycurrent
payShieldCommsHost
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.4.2
payShieldCommsHostTCPServer
OBJECT-TYPE
Indicates whether the process to service host commands is currently running over the Ethernet host port using the TCP protocol. payShieldCommsHostTCPServerUp (1) indicates that it is; all the other states indicate that TCP is currently inactive.
1.3.6.1.4.1.4096.2.2.10000.4.2.1INTEGER {serverUp(1), serverDown(2), serverNotEnabled(3)}read-onlycurrent
payShieldCommsHostUDPServer
OBJECT-TYPE
Indicates whether the process to service host commands is currently running over the Ethernet host port using the UDP protocol. payShieldCommsHostUDPServerUp (1) indicates that it is; all the other states indicate that UDP is currently inactive.
1.3.6.1.4.1.4096.2.2.10000.4.2.2INTEGER {serverUp(1), serverDown(2), serverNotEnabled(3)}read-onlycurrent
payShieldCommsHostFICONServer
OBJECT-TYPE
Indicates whether the process to service host commands is currently running over the FICON host port. payShieldCommsHostFICONServerUp (1) indicates that it is; all the other states indicate that FICON is currently inactive.
1.3.6.1.4.1.4096.2.2.10000.4.2.3INTEGER {serverUp(1), serverDown(2), serverNotEnabled(3)}read-onlycurrent
payShieldCommsHostPort
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.4.2.4
payShieldCommsHostPortEthernet1
OBJECT-TYPE
Indicates if the first host ethernet port is up and running.
1.3.6.1.4.1.4096.2.2.10000.4.2.4.1INTEGER {portUp(1), portDown(2), portUnavailable(3), portNotConfigured(4)}read-onlycurrent
payShieldCommsHostPortEthernet2
OBJECT-TYPE
Indicates if the second host ethernet port is up and running.
1.3.6.1.4.1.4096.2.2.10000.4.2.4.2INTEGER {portUp(1), portDown(2), portUnavailable(3), portNotConfigured(4)}read-onlycurrent
payShieldCommsHostPortFICON
OBJECT-TYPE
Indicates if the FICON port (if present) is up and running.
1.3.6.1.4.1.4096.2.2.10000.4.2.4.3INTEGER {portUp(1), portDown(2), portUnavailable(3), portNotConfigured(4)}read-onlycurrent
payShieldSystem
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.5
payShieldSystemDateAndTime
OBJECT-TYPE
The date and time as reported by the system's Real Time Clock.
1.3.6.1.4.1.4096.2.2.10000.5.1DateAndTimeread-onlycurrent
payShieldSystemSerialNum
OBJECT-TYPE
Displays the serial number of the payShield system.
1.3.6.1.4.1.4096.2.2.10000.5.2OCTET STRING (SIZE(0..32))read-onlycurrent
payShieldSystemModel
OBJECT-TYPE
Displays the model/series information of the payShield system.
1.3.6.1.4.1.4096.2.2.10000.5.3DisplayStringread-onlycurrent
payShieldFraud
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.6
payShieldFraudPinVerifyLimitsExceeded
OBJECT-TYPE
Returns TRUE if fraud detection is turned on, and either the allowable PIN verifications/minute, or PIN verifications/hour, have been exceeded.
1.3.6.1.4.1.4096.2.2.10000.6.1TruthValueread-onlycurrent
payShieldFraudPinAttackLimitsExceeded
OBJECT-TYPE
Returns TRUE if fraud detection is turned on, AND the total number of PIN attacks have exceeded the allowed count.
1.3.6.1.4.1.4096.2.2.10000.6.2TruthValueread-onlycurrent
payShieldVersion
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.7
payShieldVersionSoftwareBaseRelease
OBJECT-TYPE
Base release of the software running on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.1DisplayStringread-onlycurrent
payShieldVersionSoftwareRevision
OBJECT-TYPE
Revision of the software running on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.2DisplayStringread-onlycurrent
payShieldVersionSoftwareBuildNumber
OBJECT-TYPE
***************** THIS OBJECT IS DEPRECATED ***************** Build number of the software running on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.3DisplayStringread-onlydeprecated
payShieldVersionSoftwareHSMCoreAPIVersion
OBJECT-TYPE
***************** THIS OBJECT IS DEPRECATED ***************** HSM core API version of the software running on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.4DisplayStringread-onlydeprecated
payShieldVersionSoftwareCPLDVersion
OBJECT-TYPE
Version of CPLD running on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.5DisplayStringread-onlycurrent
payShieldVersionSoftwareSPVersion
OBJECT-TYPE
Version of Sensor Processor software running on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.6DisplayStringread-onlycurrent
payShieldVersionSoftwareSPBootVersion
OBJECT-TYPE
Version of Sensor Processor boot on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.7DisplayStringread-onlycurrent
payShieldVersionSoftwareBootstrapVersion
OBJECT-TYPE
Version of bootstrap on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.8DisplayStringread-onlycurrent
payShieldVersionSoftwareFirmwareVersion
OBJECT-TYPE
Semantic version of firmware on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.9DisplayStringread-onlycurrent
payShieldVersionSoftwareDeploymentVersion
OBJECT-TYPE
Semantic deployment version of firmware on the payShield.
1.3.6.1.4.1.4096.2.2.10000.7.10DisplayStringread-onlycurrent
payShieldLicensing
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.8
payShieldLicensingPerformanceModel
OBJECT-TYPE
The maximum calls per second this payShield unit is licensed for.
1.3.6.1.4.1.4096.2.2.10000.8.1Integer32read-onlycurrent
payShieldLicensingPackage
OBJECT-TYPE
The license package loaded on this payShield unit.
1.3.6.1.4.1.4096.2.2.10000.8.2OCTET STRING (SIZE(0..2048))read-onlycurrent
payShieldLicensingOptionalLicenseCount
OBJECT-TYPE
The number of optional licenses this payShield unit has installed.
1.3.6.1.4.1.4096.2.2.10000.8.3Integer32read-onlycurrent
payShieldLicensingOptionalLicensesList
OBJECT-TYPE
The optional licenses this payShield unit is licensed for separated by ';'.
1.3.6.1.4.1.4096.2.2.10000.8.4OCTET STRING (SIZE(0..2048))read-onlycurrent
payShieldLicensingCryptoAlgorithmCount
OBJECT-TYPE
The number of Cryptographic Algorithms enabled by the payShield's licensing.
1.3.6.1.4.1.4096.2.2.10000.8.5Integer32read-onlycurrent
payShieldLicensingCryptoAlgorithmList
OBJECT-TYPE
List of licensed Cryptographic Algorithms. These will be descriptive strings for each algorithm terminated by a semi-colon ';'. The number of licensed algorithms in the list will be equal to payShieldLicensingCryptoAlgorithmCount.
1.3.6.1.4.1.4096.2.2.10000.8.6OCTET STRINGread-onlycurrent
payShieldEnabledHostCommands
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.9
payShieldEnabledHostCommandsCount
OBJECT-TYPE
The number of host commands enabled on this payShield.
1.3.6.1.4.1.4096.2.2.10000.9.1Integer32read-onlycurrent
payShieldEnabledHostCommandsList
OBJECT-TYPE
Entire list of enabled host commands separated by a semi-colon ';'.
1.3.6.1.4.1.4096.2.2.10000.9.2OCTET STRING (SIZE(0..2048))read-onlycurrent
payShieldLogs
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.10
payShieldLogsErrorlog
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.10.1
payShieldLogsErrorlogTotalCount
OBJECT-TYPE
Total number of entries in the error log.
1.3.6.1.4.1.4096.2.2.10000.10.1.1Integer32read-onlycurrent
payShieldLogsErrorlogMaxLength
OBJECT-TYPE
Maximum number of entries in the error log.
1.3.6.1.4.1.4096.2.2.10000.10.1.2Integer32read-onlycurrent
payShieldLogsAuditlog
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.10.2
payShieldLogsAuditlogTotalCount
OBJECT-TYPE
Total number of entries in the audit log.
1.3.6.1.4.1.4096.2.2.10000.10.2.1Integer32read-onlycurrent
payShieldLogsAuditlogMaxLength
OBJECT-TYPE
Maximum number of entries in the audit log.
1.3.6.1.4.1.4096.2.2.10000.10.2.2Integer32read-onlycurrent
payShieldHealth
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.11
payShieldHealthDiagSelfTest
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.11.1
payShieldHealthDiagSelfTestTimeOfDay
OBJECT-TYPE
The number of minutes after midnight the diagnostic tests begins at.
1.3.6.1.4.1.4096.2.2.10000.11.1.1Integer32read-onlycurrent
payShieldHealthDiagSelfTestOK
OBJECT-TYPE
True unless one or more of the tests in the last self test failed.
1.3.6.1.4.1.4096.2.2.10000.11.1.2TruthValueread-onlycurrent
payShieldHealthDiagSelfTestCount
OBJECT-TYPE
The number of self tests run last test cycle on this payShield.
1.3.6.1.4.1.4096.2.2.10000.11.1.3Integer32read-onlycurrent
payShieldHealthDiagSelfTestList
OBJECT-TYPE
The complete results of the last run self test. Syntax of string Testname:testresult; Test/results pairs are separated by a colon ':' They are delimited by a semi-colon ; . Results are the string 'passed' or 'failed'. The number of self tests in the list will be equal to payShieldHealthDiagSelfTestCount.
1.3.6.1.4.1.4096.2.2.10000.11.1.4OCTET STRING (SIZE(0..2048))read-onlycurrent
payShieldHealthCheckCounts
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.11.2
payShieldHealthHealthCheckEnabled
OBJECT-TYPE
Whether the payShield is presently collecting health check data.
1.3.6.1.4.1.4096.2.2.10000.11.2.1TruthValueread-onlycurrent
payShieldHealthCheckCountsStartTime
OBJECT-TYPE
Date/Time of last health stats reset.
1.3.6.1.4.1.4096.2.2.10000.11.2.2DateAndTimeread-onlycurrent
payShieldHealthCheckCountsEndTime
OBJECT-TYPE
Date/time of when stats collecting was last disabled. If health stats are not disabled, the Date/Time when this field was read.
1.3.6.1.4.1.4096.2.2.10000.11.2.3DateAndTimeread-onlycurrent
payShieldHealthCheckCountsRebootCount
OBJECT-TYPE
Number of times the payShield rebooted since the last reset of health counters.
1.3.6.1.4.1.4096.2.2.10000.11.2.4Integer32read-onlycurrent
payShieldHealthCheckCountsTamperCount
OBJECT-TYPE
The number of tampers detected since the last reset of health counters.
1.3.6.1.4.1.4096.2.2.10000.11.2.5Integer32read-onlycurrent
payShieldHealthCheckCountsPinFailuresMinuteLimit
OBJECT-TYPE
The number of minutes in which the maximum pin verify failures was exceeded since the last reset of health counters.
1.3.6.1.4.1.4096.2.2.10000.11.2.6Integer32read-onlycurrent
payShieldHealthCheckCountsPinFailuresHourLimit
OBJECT-TYPE
The number of hours in which the maximum allowable pin failures per hour was exceeded since the last reset of health counters.
1.3.6.1.4.1.4096.2.2.10000.11.2.7Integer32read-onlycurrent
payShieldHealthCheckCountsPinAttackLimitExceeded
OBJECT-TYPE
The number of times the pin attack limit was exceeded since the last reset of health counters.
1.3.6.1.4.1.4096.2.2.10000.11.2.8Integer32read-onlycurrent
payShieldHostConnection
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.12
payShieldHostConnectionEthernetEnabled
OBJECT-TYPE
Whether the payShield is configured to provide ethernet host interfaces.
1.3.6.1.4.1.4096.2.2.10000.12.1TruthValueread-onlycurrent
payShieldHostConnectionFICONEnabled
OBJECT-TYPE
Whether or not the payShield is configured to provide a FICON host interface.
1.3.6.1.4.1.4096.2.2.10000.12.2TruthValueread-onlycurrent
payShieldHostConnectionEthernet
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.12.3
payShieldHostConnectionEthernetIfCount
OBJECT-TYPE
The number of physical ethernet interfaces enabled to process host commands. This will be 1 or 2.
1.3.6.1.4.1.4096.2.2.10000.12.3.1Integer32read-onlycurrent
payShieldHostConnectionEthernetSSLEnabled
OBJECT-TYPE
If true TLS/SSL has been enabled.
1.3.6.1.4.1.4096.2.2.10000.12.3.2TruthValueread-onlycurrent
payShieldHostConnectionEthernetACLsEnabled
OBJECT-TYPE
Whether Access Control Lists are enabled.
1.3.6.1.4.1.4096.2.2.10000.12.3.3TruthValueread-onlycurrent
payShieldHostConnectionEthernetUDPEnabled
OBJECT-TYPE
Whether UDP is enabled.
1.3.6.1.4.1.4096.2.2.10000.12.3.4TruthValueread-onlycurrent
payShieldHostConnectionEthernetTCPEnabled
OBJECT-TYPE
Whether TCP is enabled.
1.3.6.1.4.1.4096.2.2.10000.12.3.5TruthValueread-onlycurrent
payShieldHostConnectionEthernetMaxTCPConnections
OBJECT-TYPE
The maximum number of TCP sessions allowed per interface. (0-64)
1.3.6.1.4.1.4096.2.2.10000.12.3.6Integer32read-onlycurrent
payShieldHostConnectionEthernetTCPKeepalive
OBJECT-TYPE
TCP keep alive timeout in minutes. (0-120)
1.3.6.1.4.1.4096.2.2.10000.12.3.7Integer32read-onlycurrent
payShieldHostConnectionEthernetWellKnownPortTCP
OBJECT-TYPE
The well known TCP port. (0-65535)
1.3.6.1.4.1.4096.2.2.10000.12.3.8Integer32read-onlycurrent
payShieldHostConnectionEthernetWellKnownPortTLS
OBJECT-TYPE
The well known TLS port. (0-65535)
1.3.6.1.4.1.4096.2.2.10000.12.3.9Integer32read-onlycurrent
payShieldHostConnectionEthernetTable
OBJECT-TYPE
The interface specific ethernet configuration/status information. For interfaces that are disabled or fields that are not relevant, all values will be set to a NULL value.
1.3.6.1.4.1.4096.2.2.10000.12.3.10not-accessiblecurrent
payShieldHostConnectionEthernetEntry
OBJECT-TYPE
An entry containing information applicable to the host ethernet connection
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1not-accessiblecurrent
payShieldHostConnectionEthernetIndex
OBJECT-TYPE
A unique value (> 0) for each host ethernet connection interface
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.1Integer32 (1..2)not-accessiblecurrent
payShieldHostConnectionEthernetConfigured
OBJECT-TYPE
Tells whether a row of the table is configured. For a 1 interface system it is possible that the configured interface could be either the first or second one.
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.2TruthValueread-onlycurrent
payShieldHostConnectionEthernetInterfaceNumber
OBJECT-TYPE
This binds a row to a physical host ethernet interface. 1 corresponds to Ethernet interface HostPortEthernet1 2 corresponds to Ethernet interface HostPortEthernet2
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.3Integer32 (1..2)read-onlycurrent
payShieldHostConnectionEthernetConfigMethod
OBJECT-TYPE
DHCP and static IP configuration are the possibilities. When statically configured, the addresses reported are from the payShield's configuration for this interface. When DHCP, the addresses obtained via DHCP are reported.
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.4INTEGER {ipMethodUnknown(0), ipMethodStatic(1), ipMethodDHCP(2)}read-onlycurrent
payShieldHostConnectionEthernetHostName
OBJECT-TYPE
Network Name is present for a DHCP configured port only. If the ethernet port is configured statically set to 'NotApplicable'. If the ethernet port is not configured set to 'Interface not enabled'.
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.5DisplayStringread-onlycurrent
payShieldHostConnectionEthernetIpAddress
OBJECT-TYPE
IP address for this interface. If this interface is not enabled returns 0.0.0.0
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.6IpAddressread-onlycurrent
payShieldHostConnectionEthernetSubnetMask
OBJECT-TYPE
Subnet mask for this interface. If this interface is not enabled returns 0.0.0.0
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.7IpAddressread-onlycurrent
payShieldHostConnectionEthernetGateway
OBJECT-TYPE
Gateway IP address used by this interface. If this interface is not enabled returns 0.0.0.0
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.8IpAddressread-onlycurrent
payShieldHostConnectionEthernetMacAddress
OBJECT-TYPE
MAC address for this ethernet interface. If this interface is not enabled returns 00:00:00:00:00:00
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.9MacAddressread-onlycurrent
payShieldHostConnectionEthernetPortSpeed
OBJECT-TYPE
Describes the speed/duplex this port is configured at. If the port is configured for 'ethernet autoselect' returns: 'ethernet autoselect(speed/duplex )' If the ethernet interface is not configured returns: 'Interface not enabled'
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.10DisplayStringread-onlycurrent
payShieldHostConnectionNumberOfConnectionsUsed
OBJECT-TYPE
The Number of TCP connections in use for this physical interface. range (0-payShieldHostConnectionMaxTCPConnections)
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.11Integer32read-onlycurrent
payShieldHostConnectionEthernetLoadCount
OBJECT-TYPE
The Load Count for the host machines
1.3.6.1.4.1.4096.2.2.10000.12.3.10.1.12DisplayStringread-onlycurrent
payShieldHostConnectionFICON
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.12.4
payShieldHostConnectionFICONControlUnitImage
OBJECT-TYPE
This is the control unit address defined in the mainframe I/O definition (CUADD on CNTLUNIT statement). (0-255)
1.3.6.1.4.1.4096.2.2.10000.12.4.1DisplayStringread-onlycurrent
payShieldHostConnectionFICONControlUnitAddress
OBJECT-TYPE
The starting unit address for this control unit. 16 devices are enumerated from this point (UNITADD on CNTLUNIT statement). (0-255)
1.3.6.1.4.1.4096.2.2.10000.12.4.2DisplayStringread-onlycurrent
payShieldHostConnectionFICONMIH
OBJECT-TYPE
This specifies the missing interrupt handler value to be used in the read device characteristics CCW for the mainframe. It is in minutes. If set to 0, the mainframe setting is used (0-60)
1.3.6.1.4.1.4096.2.2.10000.12.4.3Integer32read-onlycurrent
payShieldManagement
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.13
payShieldManagementEthernet
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.13.1
payShieldManagementEthernetEnabled
OBJECT-TYPE
Whether management ethernet interface is enabled.
1.3.6.1.4.1.4096.2.2.10000.13.1.1TruthValueread-onlycurrent
payShieldManagementEthernetConfigMethod
OBJECT-TYPE
The method the management ethernet interface uses to obtain its ethernet address. Static - uses local stored information DHCP - obtains settings from the network
1.3.6.1.4.1.4096.2.2.10000.13.1.2INTEGER {ipMethodUnknown(0), ipMethodStatic(1), ipMethodDHCP(2)}read-onlycurrent
payShieldManagementEthernetNetworkName
OBJECT-TYPE
The name the payShield assigns to this interface if in DHCP mode. If the ethernet port is configured statically, set to 'DoesNotApply'.
1.3.6.1.4.1.4096.2.2.10000.13.1.3DisplayStringread-onlycurrent
payShieldManagementEthernetIpAddress
OBJECT-TYPE
The management ethernet interface's IP address. If payShieldManagementEthernetConfigMethod is set to DHCP, it will be set by the network. If payShieldManagementEthernetConfigMethod is set to static, it will be set to the payShield's configured value. A value of 0.0.0.0 means it is not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.13.1.4IpAddressread-onlycurrent
payShieldManagementEthernetSubnetMask
OBJECT-TYPE
The management ethernet interface's IP subnet mask. If payShieldManagementEthernetConfigMethod is set to DHCP, it will be set by the network. If payShieldManagementEthernetConfigMethod is set to static, it will be set to the payShield's configured value. A value of 0.0.0.0 means it was not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.13.1.5IpAddressread-onlycurrent
payShieldManagementEthernetGateway
OBJECT-TYPE
The management ethernet interface's IP gateway address. If payShieldManagementEthernetConfigMethod is set to DHCP, it will be set by the network. If payShieldManagementEthernetConfigMethod is set to Static it will be set to the payShield's configured value. A value of 0.0.0.0 means it was not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.13.1.6IpAddressread-onlycurrent
payShieldManagementEthernetMacAddress
OBJECT-TYPE
The management ethernet interface's MAC address. Will be set to 00:00:00:00:00:00 if not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.13.1.7MacAddressread-onlycurrent
payShieldManagementEthernetPortSpeed
OBJECT-TYPE
String that describes the speed configured and the actual connection properties. Form is config (actual) eg : ethernet autoselect (100baseTX full-duplex)
1.3.6.1.4.1.4096.2.2.10000.13.1.8DisplayStringread-onlycurrent
payShieldPrinter
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.14
payShieldPrinterLFCRReversed
OBJECT-TYPE
Whether LF and CR are reversed.
1.3.6.1.4.1.4096.2.2.10000.14.1TruthValueread-onlycurrent
payShieldPrinterTimeout
OBJECT-TYPE
Printer timeout value in milliseconds. (1000, 86400000)
1.3.6.1.4.1.4096.2.2.10000.14.2Integer32read-onlycurrent
payShieldPrinterDelay
OBJECT-TYPE
Printer delay in milliseconds (0-7200000)
1.3.6.1.4.1.4096.2.2.10000.14.3Integer32read-onlycurrent
payShieldPrinterReport
OBJECT-TYPE
The report of the dynamic state of printers in the system as produced for QP and the payShield Manager. It will consist of printable characters.
1.3.6.1.4.1.4096.2.2.10000.14.4OCTET STRING (SIZE(0..2000))read-onlycurrent
payShieldSettings
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.15
payShieldSettingsPCICompliant
OBJECT-TYPE
True if all security settings are PCI compliant.
1.3.6.1.4.1.4096.2.2.10000.15.1TruthValueread-onlycurrent
payShieldSettingsHashSecuritySetting
OBJECT-TYPE
Hash value for security settings.
1.3.6.1.4.1.4096.2.2.10000.15.2DisplayStringread-onlycurrent
payShieldSettingsHashGeneralSetting
OBJECT-TYPE
Hash value for general settings.
1.3.6.1.4.1.4096.2.2.10000.15.3DisplayStringread-onlycurrent
payShieldSettingsHashConfigureCommand
OBJECT-TYPE
Hash value for configure command.
1.3.6.1.4.1.4096.2.2.10000.15.4DisplayStringread-onlycurrent
payShieldSettingsHashAuditSetting
OBJECT-TYPE
Hash value for audit settings.
1.3.6.1.4.1.4096.2.2.10000.15.5DisplayStringread-onlycurrent
payShieldSettingsHashLMK
OBJECT-TYPE
Hash value for LMK.
1.3.6.1.4.1.4096.2.2.10000.15.6DisplayStringread-onlycurrent
payShieldAuxiliaryEthernet
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.16
payShieldAuxiliaryEthernetEnabled
OBJECT-TYPE
Whether auxiliary ethernet interface is enabled.
1.3.6.1.4.1.4096.2.2.10000.16.1TruthValueread-onlycurrent
payShieldAuxiliaryEthernetConfigMethod
OBJECT-TYPE
The method the auxiliary ethernet interface uses to obtain its ethernet address. Static - uses local stored information DHCP - obtains settings from the network
1.3.6.1.4.1.4096.2.2.10000.16.2INTEGER {ipMethodUnknown(0), ipMethodStatic(1), ipMethodDHCP(2)}read-onlycurrent
payShieldAuxiliaryEthernetNetworkName
OBJECT-TYPE
The name the payShield assigns to this interface if in DHCP mode. If the ethernet port is configured statically, set to 'DoesNotApply'.
1.3.6.1.4.1.4096.2.2.10000.16.3DisplayStringread-onlycurrent
payShieldAuxiliaryEthernetIpAddress
OBJECT-TYPE
The auxiliary ethernet interface's IP address. If payShieldAuxiliaryEthernetConfigMethod is set to DHCP, it will be set by the network. If payShieldAuxiliaryEthernetConfigMethod is set to static, it will be set to the payShield's configured value. A value of 0.0.0.0 means it is not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.16.4IpAddressread-onlycurrent
payShieldAuxiliaryEthernetSubnetMask
OBJECT-TYPE
The auxiliary ethernet interface's IP subnet mask. If payShieldAuxiliaryEthernetConfigMethod is set to DHCP, it will be set by the network. If payShieldAuxiliaryEthernetConfigMethod is set to static, it will be set to the payShield's configured value. A value of 0.0.0.0 means it was not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.16.5IpAddressread-onlycurrent
payShieldAuxiliaryEthernetGateway
OBJECT-TYPE
The auxiliary ethernet interface's IP gateway address. If payShieldManagementEthernetConfigMethod is set to DHCP, it will be set by the network. If payShieldManagementEthernetConfigMethod is set to static, it will be set to the payShield's configured value. A value of 0.0.0.0 means it was not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.16.6IpAddressread-onlycurrent
payShieldAuxiliaryEthernetMacAddress
OBJECT-TYPE
The auxiliary ethernet interface's MAC address. Will be set to 00:00:00:00:00:00 if not successfully fetched.
1.3.6.1.4.1.4096.2.2.10000.16.7MacAddressread-onlycurrent
payShieldAuxiliaryEthernetPortSpeed
OBJECT-TYPE
String that describes the speed configured and the actual connection properties. Form is config (actual) eg: ethernet autoselect (100baseTX full-duplex)
1.3.6.1.4.1.4096.2.2.10000.16.8DisplayStringread-onlycurrent
payShieldMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.100
payShieldMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.100.1
payShieldMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.4096.2.2.10000.100.2
notifications
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999
payShieldNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2
payShieldAlarmObjects
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1
payShieldAlarmFans
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.1
payShieldFanNumber
OBJECT-TYPE
Identifies fan1 or fan2.
1.3.6.1.4.1.4096.999.2.1.1.1INTEGER {fan1(1), fan2(2)}accessible-for-notifycurrent
payShieldFanState
OBJECT-TYPE
Provides the state of the fan.
1.3.6.1.4.1.4096.999.2.1.1.2INTEGER {stateOK(1), stateFailure(2), stateNotDetected(3)}accessible-for-notifycurrent
payShieldAlarmPSU
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.2
payShieldPSUNumber
OBJECT-TYPE
Identifies the power supply unit 1 or 2.
1.3.6.1.4.1.4096.999.2.1.2.1INTEGER {psu1(1), psu2(2)}accessible-for-notifycurrent
payShieldPSUState
OBJECT-TYPE
Provides the state of the PSU.
1.3.6.1.4.1.4096.999.2.1.2.2INTEGER {stateOK(1), stateFailure(2), stateNotDetected(3)}accessible-for-notifycurrent
payShieldAlarmBadPortData
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.3
payShieldBadDataPhysicalPort
OBJECT-TYPE
The physical port the bad data was detected on.
1.3.6.1.4.1.4096.999.2.1.3.1INTEGER {portHost1(1), portHost2(2), portFICON(3)}accessible-for-notifycurrent
payShieldBadDataProtocol
OBJECT-TYPE
The method that bad data detected was transmitted.
1.3.6.1.4.1.4096.999.2.1.3.2INTEGER {protocolTCP(1), protocolUDP(2), protocolFICON(3)}accessible-for-notifycurrent
payShieldAlarmErrorLog
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.4
payShieldErrorLogData
OBJECT-TYPE
A textual error log entry as stored in the system.
1.3.6.1.4.1.4096.999.2.1.4.1DisplayStringaccessible-for-notifycurrent
payShieldAlarmBattery
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.5
payShieldBatteryState
OBJECT-TYPE
State of the battery.
1.3.6.1.4.1.4096.999.2.1.5.1INTEGER {stateOK(1), stateWarning(2), stateFailure(3)}accessible-for-notifycurrent
payShieldAlarmDiagnostic
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.6
payShieldDiagnosticID
OBJECT-TYPE
Diagnostic identifier as a code.
1.3.6.1.4.1.4096.999.2.1.6.1INTEGER {diagDES(1), diagAES(2), diagECDSA(3), diagHMAC(4), diagMD5(5), diagSHA(6), diagRSA(7), diagRNG(8), diagRTC(9), diagMemory(10), diagPower(11), diagBattery(12), diagFans(13), diagTemperature(14), diagVoltage(15), diagUDP(16), diagTCP(17), diagFICON(18)}accessible-for-notifycurrent
payShieldDiagnosticString
OBJECT-TYPE
Diagnostic identifier as a string.
1.3.6.1.4.1.4096.999.2.1.6.2DisplayStringaccessible-for-notifycurrent
payShieldAlarmFraud
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.7
payShieldFraudType
OBJECT-TYPE
Indicates what sort of fraud event took place.
1.3.6.1.4.1.4096.999.2.1.7.1INTEGER {fraudExceededFailuresPerMinute(1), fraudExceededFailuresPerHour(2), fraudExceededAttackLimit(3)}accessible-for-notifycurrent
payShieldAlarmErase
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.8
payShieldAlarmEraseTimeandDate
OBJECT-TYPE
Indicates the time and date when the erase button was pressed.
1.3.6.1.4.1.4096.999.2.1.8.1DateAndTime (SIZE(8))accessible-for-notifycurrent
payShieldAlarmSettingsModified
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.9
payShieldModifiedSetting
OBJECT-TYPE
Collection of settings whose modifications will trigger a notification.
1.3.6.1.4.1.4096.999.2.1.9.1INTEGER {settingSecurity(1), settingPCI(2), settingAuditedItems(3), settingEnabledPinblocks(4)}accessible-for-notifycurrent
payShieldAlarmStateChange
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.10
payShieldDeviceState
OBJECT-TYPE
Provides the new state of the payShield.
1.3.6.1.4.1.4096.999.2.1.10.1INTEGER {stateUnavailable(1), stateOnline(2), stateOffline(3), stateSecure(4)}accessible-for-notifycurrent
payShieldAlarmTamper
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.1.11
payShieldTamperCause
OBJECT-TYPE
The cause of the tamper event.
1.3.6.1.4.1.4096.999.2.1.11.1INTEGER {causeUnavailable(1), causeTemperatureOutOfRange(2), causeBatteryLow(3), causeEraseButtonPressed(4), causeSensorProcessorWatchdog(5), causeSensorProcessorRestart(6), causeVoltageOutOfRange(7), causeMotionDetected(8), causeCaseTampered(9), causePowerLoss(10)}accessible-for-notifycurrent
payShieldTamperDate
OBJECT-TYPE
The Date and Time that the tamper event occurred.
1.3.6.1.4.1.4096.999.2.1.11.2DateAndTimeaccessible-for-notifycurrent
payShieldTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4096.999.2.2

Notifications

NameOIDStatus
payShieldPowerOnAlarm
NOTIFICATION-TYPE
SNMP Trap indicating the unit has been powered up.
1.3.6.1.4.1.4096.999.2.2.1current
payShieldRestartAlarm
NOTIFICATION-TYPE
************ THIS NOTIFICATION IS DEPRECATED ************* SNMP trap generated when the reset button has been pressed.
1.3.6.1.4.1.4096.999.2.2.2deprecated
payShieldEraseAlarm
NOTIFICATION-TYPE
SNMP trap indicating that the Erase button was pressed.
1.3.6.1.4.1.4096.999.2.2.3current
payShieldNewLicenseAlarm
NOTIFICATION-TYPE
SNMP trap indicating the installation of a new license.
1.3.6.1.4.1.4096.999.2.2.4current
payShieldNewSoftwareAlarm
NOTIFICATION-TYPE
SNMP trap indicating that new software has been installed.
1.3.6.1.4.1.4096.999.2.2.5current
payShieldPSUAlarm
NOTIFICATION-TYPE
SNMP trap indicating a change in the state of a Power supply unit.
1.3.6.1.4.1.4096.999.2.2.6current
payShieldBatteryAlarm
NOTIFICATION-TYPE
SNMP trap indicating a change in the state of the Battery.
1.3.6.1.4.1.4096.999.2.2.7current
payShieldFanAlarm
NOTIFICATION-TYPE
SNMP trap notifying a change in the state of a Fan unit.
1.3.6.1.4.1.4096.999.2.2.8current
payShieldTamperAlarm
NOTIFICATION-TYPE
SNMP trap indicating a tamper has been detected. Detected tamper is reported.
1.3.6.1.4.1.4096.999.2.2.9current
payShieldHostPortBadDataAlarm
NOTIFICATION-TYPE
SNMP trap indicating that protocol breaking data has arrived on a port. Indicates which physical interface it arrived on and what protocol was being used.
1.3.6.1.4.1.4096.999.2.2.10current
payShieldFraudAlarm
NOTIFICATION-TYPE
SNMP trap that indicates a fraud limit was exceeded.
1.3.6.1.4.1.4096.999.2.2.11current
payShieldDiagnosticTestFailureAlarm
NOTIFICATION-TYPE
SNMP trap indicating that a diagnostic test has failed. Indicates which test failed.
1.3.6.1.4.1.4096.999.2.2.12current
payShieldErrorlogAlarm
NOTIFICATION-TYPE
SNMP trap that indicates an error log entry has been filled. Contains the entry.
1.3.6.1.4.1.4096.999.2.2.13current
payShieldSettingsModifiedAlarm
NOTIFICATION-TYPE
SNMP trap that indicates a setting of the payShield has been modified. It includes a payShieldModifiedSetting object which identifies the setting that was changed.
1.3.6.1.4.1.4096.999.2.2.14current
payShieldDeviceStateAlarm
NOTIFICATION-TYPE
SNMP trap that indicates a change in payShield device state. It includes a payShieldDeviceState object which provides the new state of the payShield.
1.3.6.1.4.1.4096.999.2.2.15current

Conformance

NameOIDStatus
payShieldMIBCompliance
MODULE-COMPLIANCE
******** THIS COMPLIANCE IS DEPRECATED ********* The compliance statement for SNMP entities which implement the payShield MIB. This compliance is deprecated and replaced by payShieldMIBCompliance2.
1.3.6.1.4.1.4096.2.2.10000.100.1.1deprecated
payShieldMIBCompliance2
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement the payShield MIB.
1.3.6.1.4.1.4096.2.2.10000.100.1.2current
payShieldObjectGroup
OBJECT-GROUP
Group of all payShield MIB objects.
1.3.6.1.4.1.4096.2.2.10000.100.2.1current
payShieldDeprecatedObjectGroup
OBJECT-GROUP
Group of deprecated payShield MIB objects.
1.3.6.1.4.1.4096.2.2.10000.100.2.2deprecated
payShieldAlarmObjectGroup
OBJECT-GROUP
Group of objects used in payShield notifications.
1.3.6.1.4.1.4096.2.2.10000.100.2.3current
payShieldNotificationGroup
NOTIFICATION-GROUP
Group of payShield notifications.
1.3.6.1.4.1.4096.2.2.10000.100.2.4current
payShieldDeprecatedNotificationGroup
NOTIFICATION-GROUP
Group of deprecated payShield notifications.
1.3.6.1.4.1.4096.2.2.10000.100.2.5deprecated