TELESTE-COMMON-MIB
- Registered at
- 1.3.6.1.4.1.3715.99.11.3.6.1.4.1.3715.99.2
- Namespace
- teleste
- Source file
TELESTE-COMMON-MIB- Digest
sha256:99b12c5471b6371b142e83c0b6d85441d54278b19d0f1c1bbfce13b00bd114d3
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
| TELESTE-ROOT-MIB | DateAndTime, TPhysAddress, Uint16, common |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC TELESTE-COMMON-MIB TELESTE-ROOT-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| element OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.1 | |||
| elementInformation OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.1.1 | |||
| elementName OBJECT-TYPE This is the logical name of the controlling module of the network element. The name may or may not be the same as the module's name in the moduleTable. | 1.3.6.1.4.1.3715.99.1.1.1 | DisplayString | read-write | mandatory |
| elementStructure OBJECT-TYPE This object tells whether the device is a single compact device or a modular device. | 1.3.6.1.4.1.3715.99.1.1.2 | INTEGER {unknown(1), compact(2), modular(3)} | read-only | mandatory |
| elementConfigChangeCode OBJECT-TYPE This object is an indicator about changes in the network element configuration. How the value is formed is device dependent. It can be a counter, a checksum of the device configuration parameters, a DateAndTime type variable or even SysUptime, if no other information is available. DateAndTime is the recommended value. This object is intended to permit a management application to maintain configuration (including moduleTable) syncronization with the agent. | 1.3.6.1.4.1.3715.99.1.1.3 | INTEGER | read-only | optional |
| elementResetCount OBJECT-TYPE Total number of software resets during the device's life time. | 1.3.6.1.4.1.3715.99.1.1.4 | INTEGER | read-only | optional |
| elementTotalUpTime OBJECT-TYPE The total uptime the device (software) has been running. Unit 1 day. | 1.3.6.1.4.1.3715.99.1.1.5 | INTEGER | read-only | mandatory |
| elementLatitude OBJECT-TYPE Device latitude coordinate. Unit 0.00001 degrees. | 1.3.6.1.4.1.3715.99.1.1.6 | INTEGER | read-write | optional |
| elementLongitude OBJECT-TYPE Device longitude coordinate. Unit 0.00001 degrees. | 1.3.6.1.4.1.3715.99.1.1.7 | INTEGER | read-write | optional |
| elementAltitude OBJECT-TYPE Device altitude coordinate. Unit 1 metre. | 1.3.6.1.4.1.3715.99.1.1.8 | INTEGER | read-write | optional |
| elementStatus OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.1.2 | |||
| statusGeneral OBJECT-TYPE A number stating the general status of the element. Values: 1 = Normal 2 = At least one Notification is active 3 = At least one Warning is active 4 = At least one Alarm is active If the element has more than one state active, then the state with the highest value is returned. | 1.3.6.1.4.1.3715.99.1.2.1 | INTEGER {normal(1), notification(2), warning(3), alarm(4)} | read-only | mandatory |
| statusBusMaster OBJECT-TYPE A number stating the Bus Master status of the NE. Values: 1 = The NE is a slave-only device 2 = The NE is configured as slave 3 = The NE is configured as master but is currently slave because a stronger master is on the bus 4 = The NE is currently the bus master | 1.3.6.1.4.1.3715.99.1.2.2 | INTEGER {slaveOnly(1), configuredSlave(2), currentlySlave(3), currentlyMaster(4)} | read-only | optional |
| statusLmt OBJECT-TYPE A number telling if the Local Management Terminal (LMT) is connected to the element. Values: 1 = The element does not have an LMT interface 2 = The element can not detect if an LMT is connected 3 = The element has not detected a connected LMT 4 = The element has detected a connected LMT Note! Applies only to fysically point-to-point connected LMT's to device, not via bus ot other shared medias. | 1.3.6.1.4.1.3715.99.1.2.3 | INTEGER {noLmtInterface(1), stateUnknown(2), notConnected(3), connected(4)} | read-only | optional |
| statusLid OBJECT-TYPE Element lid status: 1 = no lid (no lid sensor is available) 2 = lid is closed 3 = lid is open | 1.3.6.1.4.1.3715.99.1.2.4 | INTEGER {noLid(1), closed(2), open(3)} | read-only | optional |
| statusTemperature OBJECT-TYPE Element temperature status: 1 = normal 2 = HIHI 3 = Hi 4 = Lo 5 = LOLO | 1.3.6.1.4.1.3715.99.1.2.5 | INTEGER {tempNormal(1), tempHIHI(2), tempHi(3), tempLo(4), tempLOLO(5)} | read-only | optional |
| statusFan OBJECT-TYPE A common status object for all fans in the device. fanNormal(1) = all fans operate normally fanFailure(2) = at least one fan has a failure | 1.3.6.1.4.1.3715.99.1.2.6 | INTEGER {fanNormal(1), fanFailure(2)} | read-only | mandatory |
| statusHardware OBJECT-TYPE Device hardware status: hwNormal(1) = the hardware operates normally hwFailure(2) = a hardware failure is detected | 1.3.6.1.4.1.3715.99.1.2.7 | INTEGER {hwNormal(1), hwFailure(2)} | read-only | mandatory |
| statusSoftware OBJECT-TYPE Device software status: swNormal(1) = the software operates normally swFailure(2) = a software failure is detected swMissing(3) = the software or firmware is missing sw(Initialising(4) = the software is initialising | 1.3.6.1.4.1.3715.99.1.2.8 | INTEGER {swNormal(1), swFailure(2), swMissing(3), swInitialising(4)} | read-only | mandatory |
| statusSettings OBJECT-TYPE Status of device settings: settingsStable(1) = settings are stable settingsChanged(2) = settings have been (recently) changed settingsNotAvailable(3) = settings status is not available The value should stay in value 2 only a predefined time, e.g. 60 seconds or the time it takes until the settings are written into non-volatile memory. | 1.3.6.1.4.1.3715.99.1.2.9 | INTEGER {settingsStable(1), settingsChanged(2), settingsNotAvailable(3)} | read-only | mandatory |
| elementControl OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.1.3 | |||
| controlResetElement OBJECT-TYPE On write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On read requests value noReset(1) is returned. | 1.3.6.1.4.1.3715.99.1.3.1 | INTEGER {noReset(1), hardReset(2), softReset(3)} | read-write | mandatory |
| controlBusMasterAdminState OBJECT-TYPE This object tells whether the element is configured as a bus master or not. Only relevant for bus master type of elements. Others return no(2). | 1.3.6.1.4.1.3715.99.1.3.2 | INTEGER {master(1), slave(2)} | read-write | optional |
| controlAlarmDetection OBJECT-TYPE This variable is used to disable or enable the element alarm checking. When disabled(1), the element will not check any alarms (or send traps). Default value is enabled(2). Note: This variable must be consistent with commonAlarmDetectionControl in SCTE-HMS-COMMON-MIB, if that is implemented. | 1.3.6.1.4.1.3715.99.1.3.3 | INTEGER {disabled(1), enabled(2), restart(3)} | read-write | mandatory |
| controlMaxNumberTrapReceivers OBJECT-TYPE Number of entries in the elementTrapReceiverTable. At least one trap entry must be supported. | 1.3.6.1.4.1.3715.99.1.3.4 | INTEGER | read-only | mandatory |
| controlTrapReceiverTable OBJECT-TYPE A table of manager trap receiver addresses, ports and communities. Total number of entries can not exceed elementNumberTrapReceivers. An entry is deleted from this table by setting its IP address to '0.0.0.0'. Note: one of the community strings must match to commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if that is implemented. | 1.3.6.1.4.1.3715.99.1.3.5 | not-accessible | optional | |
| controlTrapReceiverEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.1.3.5.1 | not-accessible | optional | |
| receiverEntryId OBJECT-TYPE Unique table index. Makes possible to have several ip-address of 0.0.0.0 entries so that no mechanism for row manipulation of table is needed. | 1.3.6.1.4.1.3715.99.1.3.5.1.1 | INTEGER (1..255) | read-only | mandatory |
| receiverAddress OBJECT-TYPE Ip address of the manager receiving Traps. | 1.3.6.1.4.1.3715.99.1.3.5.1.2 | IpAddress | read-write | mandatory |
| receiverPort OBJECT-TYPE Trap UDP port number. Default port is the standard trap port 162. | 1.3.6.1.4.1.3715.99.1.3.5.1.3 | INTEGER (1..65535) | read-write | mandatory |
| receiverCommunity OBJECT-TYPE Community string for the trap receiver. The agent is allowed to limit the length of the string. Minimum length of eight characters must be supported. Note: one of the community strings must match to commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if that is implemented. | 1.3.6.1.4.1.3715.99.1.3.5.1.4 | DisplayString | read-write | mandatory |
| controlTrapSending OBJECT-TYPE Enables/disables trap sending. 1 = traps enabled 2 = traps disabled | 1.3.6.1.4.1.3715.99.1.3.6 | INTEGER {enabled(1), disabled(2)} | read-write | optional |
| controlTrapInterval OBJECT-TYPE The minimum interval between traps. - Unit 10 milliseconds - Minimum value 0 (send as fast as possible) - Maximum value 1000 (10 seconds) - Default value is 100 (1 second) | 1.3.6.1.4.1.3715.99.1.3.7 | INTEGER | read-write | optional |
| controlTrapLifeTime OBJECT-TYPE The maximum time a trap stays in the trap queue waiting for sending. - Unit 1 second. - Minimum value 10 - Maximum value 300 - Default value 60 | 1.3.6.1.4.1.3715.99.1.3.8 | INTEGER | read-write | optional |
| controlAlarmOnDelay OBJECT-TYPE The minimum time an object's alarm/warning condition must exist before it is recorded as an alarm/warning. Common to all alarms/warnings - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 100 (1 second) | 1.3.6.1.4.1.3715.99.1.3.9 | INTEGER | read-write | optional |
| controlAlarmOffDelay OBJECT-TYPE The minimum time an alarm/warning entry stays active after the object has reached it's normal condition. Common to all alarms/warnings. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - default value 100 (1 second) | 1.3.6.1.4.1.3715.99.1.3.10 | INTEGER | read-write | optional |
| controlTrapDelay OBJECT-TYPE The time before a trap is sent after an alarm is detected. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 500 (5 seconds) This parameter can be used to control alarm storms e.g. in an amplifier cascade by using a different value in each amplifier. | 1.3.6.1.4.1.3715.99.1.3.11 | INTEGER | read-write | optional |
| elementProductKey OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.1.4 | |||
| productKeyNumberOfKeys OBJECT-TYPE Number of product keys supported by the device. | 1.3.6.1.4.1.3715.99.1.4.4 | INTEGER | read-only | optional |
| productKeyTable OBJECT-TYPE | 1.3.6.1.4.1.3715.99.1.4.5 | not-accessible | mandatory | |
| productKeyEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.1.4.5.1 | not-accessible | mandatory | |
| productKeyIndex OBJECT-TYPE Product key index. | 1.3.6.1.4.1.3715.99.1.4.5.1.1 | INTEGER (1..16) | read-only | mandatory |
| productKeyValue OBJECT-TYPE Product key value. | 1.3.6.1.4.1.3715.99.1.4.5.1.2 | OCTET STRING | read-write | mandatory |
| productKeyMask OBJECT-TYPE Product key mask. | 1.3.6.1.4.1.3715.99.1.4.5.1.3 | OCTET STRING | read-only | mandatory |
| productKeyStatus OBJECT-TYPE Product key status: 1(keyInvalid) = the key is invalid or missing 2(keyValid) = the key is valid | 1.3.6.1.4.1.3715.99.1.4.5.1.4 | INTEGER {keyInvalid(1), keyValid(2)} | read-only | mandatory |
| productKeyCipher OBJECT-TYPE Cipher method supported by this key: 1(cipherOther) = other ciphering is used 2(cipherBlowFish) = BlowFish ciphering is used 3(cipherXXTEA) = XXTEA ciphering is used | 1.3.6.1.4.1.3715.99.1.4.5.1.5 | INTEGER {cipherOther(1), cipherBlowFish(2), cipherXXTEA(3)} | read-only | mandatory |
| productKeyNumberOfFeatures OBJECT-TYPE Number of features available with this key. | 1.3.6.1.4.1.3715.99.1.4.5.1.6 | INTEGER | read-only | mandatory |
| productKeyFeatureTable OBJECT-TYPE | 1.3.6.1.4.1.3715.99.1.4.6 | not-accessible | mandatory | |
| productKeyFeatureEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.1.4.6.1 | not-accessible | mandatory | |
| productKeyFeatureIndex OBJECT-TYPE Feature index (second index). | 1.3.6.1.4.1.3715.99.1.4.6.1.1 | INTEGER (1..32) | read-only | mandatory |
| productKeyFeatureName OBJECT-TYPE A human-readable description of the feature. | 1.3.6.1.4.1.3715.99.1.4.6.1.2 | OCTET STRING | read-only | mandatory |
| productKeyFeatureEnable OBJECT-TYPE Status of the feature: 1(featureDisable) = the feature si disabled in this device 2(featureEnable) = the feature is enabled in this devices | 1.3.6.1.4.1.3715.99.1.4.6.1.3 | INTEGER {featureDisable(1), featureEnable(2)} | read-only | mandatory |
| productKeyFeatureExpirationTime OBJECT-TYPE Number of days left before the feature expires. A zero value means infinite validity time. This object has a meaning only if the feature is enabled (productKeyFeatureEnable = 2(featureEnable)). | 1.3.6.1.4.1.3715.99.1.4.6.1.4 | INTEGER | read-only | mandatory |
| module OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.2 | |||
| moduleInformation OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.2.1 | |||
| moduleTable OBJECT-TYPE This table lists basic module identification and configuration data of modules installed inside the managed element. The first row in the table list information about the element itself. If the element is not modular, only the first row exists in the table. Object moduleId is used for indexing the modules in all module section tables. | 1.3.6.1.4.1.3715.99.2.1.1 | not-accessible | mandatory | |
| moduleEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.1.1.1 | not-accessible | mandatory | |
| moduleId OBJECT-TYPE An unique module index identifying the (physical) modules inside the network element. The exact conjunction between the index and the physical modules depends on the element structural principle. For network elements containing plug-in modules the index should follow module slot numbering. This index should be used in all subsequent module tables. | 1.3.6.1.4.1.3715.99.2.1.1.1.1 | INTEGER (1..65535) | read-only | mandatory |
| moduleName OBJECT-TYPE The identification name ('aliasname') of the module. | 1.3.6.1.4.1.3715.99.2.1.1.1.2 | DisplayString | read-write | optional |
| moduleHwType OBJECT-TYPE The hardware type name of the module. | 1.3.6.1.4.1.3715.99.2.1.1.1.3 | DisplayString | read-only | mandatory |
| moduleRackNo OBJECT-TYPE Rack number of the module. This can be used to identify the physical position of the module in the case where the agent manages modules that are in several racks. | 1.3.6.1.4.1.3715.99.2.1.1.1.4 | INTEGER | read-write | optional |
| moduleSlotNo OBJECT-TYPE Slot number of the module (within rack). | 1.3.6.1.4.1.3715.99.2.1.1.1.5 | INTEGER | read-write | optional |
| moduleDetailTable OBJECT-TYPE This table lists detailed module data of modules installed inside the element. The first row in the table list information about the element itself. If the element is not modular, only the first row exists in the table. | 1.3.6.1.4.1.3715.99.2.1.2 | not-accessible | mandatory | |
| moduleDetailEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.1.2.1 | not-accessible | mandatory | |
| moduleMacAddress OBJECT-TYPE Module MAC address. If the MAC address is unknown '00.00.00.00.00.00' is returned. | 1.3.6.1.4.1.3715.99.2.1.2.1.1 | TPhysAddress | read-only | optional |
| moduleBusAddress OBJECT-TYPE Module bus address. | 1.3.6.1.4.1.3715.99.2.1.2.1.2 | INTEGER | read-only | optional |
| moduleAppDate OBJECT-TYPE Module application software date. | 1.3.6.1.4.1.3715.99.2.1.2.1.3 | DateAndTime | read-only | mandatory |
| moduleAppVersion OBJECT-TYPE Module application software version. If software version is undefined, then zero length string is returned. | 1.3.6.1.4.1.3715.99.2.1.2.1.4 | DisplayString | read-only | mandatory |
| moduleBiosDate OBJECT-TYPE Module BIOS date. | 1.3.6.1.4.1.3715.99.2.1.2.1.5 | DateAndTime | read-only | mandatory |
| moduleBiosVersion OBJECT-TYPE Module BIOS version. If bios version is undefined, a zero length string is returned. | 1.3.6.1.4.1.3715.99.2.1.2.1.6 | DisplayString | read-only | mandatory |
| moduleHwSerialNumber OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.3715.99.2.1.2.1.7 | DisplayString | read-only | mandatory |
| moduleHwVersion OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.3715.99.2.1.2.1.8 | DisplayString | read-only | mandatory |
| moduleStatus OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.2.2 | |||
| moduleStatusTable OBJECT-TYPE This table contains status objects for modules inside the network element.The first row in the table lists information about the host module. If the element is not modular, only the first row exists in the table. | 1.3.6.1.4.1.3715.99.2.2.1 | not-accessible | mandatory | |
| moduleStatusEntry OBJECT-TYPE Row in moduleStatusTable. The index is moduleId from the moduleTable. Row in this table exist only if there is a row with the same moduleId in the moduleTable. | 1.3.6.1.4.1.3715.99.2.2.1.1 | not-accessible | mandatory | |
| statusResetCause OBJECT-TYPE Reason for the last reset. If the reason is unknown, the value is reasonUnknown(1). If the device makes self reset and it can detect it, then value is reasonSelfReset(2). If the reset was made by the user from the power switch and it can be sensed, then the value is reasonPowerReset(3). If the reason is an external command from the user interface or from the network message (e.g. commonReset), then the reason is reasonCommandedReset(4). | 1.3.6.1.4.1.3715.99.2.2.1.1.1 | INTEGER {unknown(1), selfReset(2), powerReset(3), commandedReset(4), softdownloadReset(5)} | read-only | mandatory |
| statusRunningSwImage OBJECT-TYPE Currently running software image number. Bios is 0, applications are numbered from 1..n, where n is the maximum image number. | 1.3.6.1.4.1.3715.99.2.2.1.1.2 | INTEGER | read-only | mandatory |
| statusInternalTemperature OBJECT-TYPE Device temperature, unit 0.1 deg C. Value is zero (0), if temperature is not available. | 1.3.6.1.4.1.3715.99.2.2.1.1.3 | INTEGER (-600..1300) | read-only | mandatory |
| statusLidStatus OBJECT-TYPE Current lid status detected by the device. May or may not be the same variable as the elementLidStatus. | 1.3.6.1.4.1.3715.99.2.2.1.1.4 | INTEGER {noLid(1), closed(2), open(3)} | read-only | optional |
| statusRestartCounter OBJECT-TYPE This objects counts the number of restarts of the module. A start can be a cold start or a warm start. | 1.3.6.1.4.1.3715.99.2.2.1.1.5 | Counter | read-only | optional |
| moduleControl OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.2.3 | |||
| moduleControlTable OBJECT-TYPE This table contains common control commands for all the modules inside the element. | 1.3.6.1.4.1.3715.99.2.3.1 | not-accessible | optional | |
| moduleControlEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.3.1.1 | not-accessible | optional | |
| controlLedUsage OBJECT-TYPE A variable to instruct how device LED's behave when the lid is closed. | 1.3.6.1.4.1.3715.99.2.3.1.1.1 | INTEGER {notSupported(1), alwaysOn(2), offWhenLidClosed(3)} | read-write | optional |
| controlMarkState OBJECT-TYPE A variable to instruct the device to start and stop showing mark (blinking module LED). On read requests returns the current mark state. | 1.3.6.1.4.1.3715.99.2.3.1.1.2 | INTEGER {notSupported(1), on(2), off(3)} | read-write | optional |
| controlReset OBJECT-TYPE On write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On read requests value noReset(1) is returned. | 1.3.6.1.4.1.3715.99.2.3.1.1.3 | INTEGER {noReset(1), hardReset(2), softReset(3)} | read-write | optional |
| controlTempLimitHiHi OBJECT-TYPE Module temperature HiHi (high alarm) limit in 0.1 degC. | 1.3.6.1.4.1.3715.99.2.3.1.1.4 | INTEGER | read-write | optional |
| controlTempLimitHi OBJECT-TYPE Module temperature Hi (high warning) limit in 0.1 degC. | 1.3.6.1.4.1.3715.99.2.3.1.1.5 | INTEGER | read-write | optional |
| controlTempLimitLo OBJECT-TYPE Module temperature Lo (low warning) limit in 0.1 degC. | 1.3.6.1.4.1.3715.99.2.3.1.1.7 | INTEGER | read-write | optional |
| controlTempLimitLoLo OBJECT-TYPE Module temperature LoLo (low alarm) limit in 0.1 degC. | 1.3.6.1.4.1.3715.99.2.3.1.1.8 | INTEGER | read-write | optional |
| controlTempDeadBand OBJECT-TYPE Module temperature alarm/warning deadband in 0.1 degC. Common to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines the difference between the 'ON' limit and the 'OFF' limit of the corresponding alarm. Example: The Hi limit is 65 degC and the deadband is 5 degC. The high warning is activated when the temperature exceeds 65 degC and deactivated only after it falls below 60 degC. | 1.3.6.1.4.1.3715.99.2.3.1.1.9 | INTEGER | read-write | optional |
| controlInternalAppAccess OBJECT-TYPE This object defines whether the internal controller application is able to access the module parameters. This corresponds to the BXX module setting 'Allow Functions'. 1 = allow internal control 2 = deny internal control (remote control is possible) | 1.3.6.1.4.1.3715.99.2.3.1.1.10 | INTEGER {allowIntControl(1), denyIntControl(2)} | read-write | optional |
| controlLocalAccess OBJECT-TYPE This object defines whether the local user interface (buttons, knobs etc.) is enabled or disabled. Values: 1 = disabled, local UI is locked 2 = enabled, local UI is active For modules/devices with no local UI this objects should return value 'disabled (1). | 1.3.6.1.4.1.3715.99.2.3.1.1.11 | INTEGER {disabled(1), enabled(2)} | read-write | optional |
| moduleSWUpdateTable OBJECT-TYPE A table of software update control objects. | 1.3.6.1.4.1.3715.99.2.3.2 | not-accessible | optional | |
| moduleSWUpdateEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.3.2.1 | not-accessible | optional | |
| sWUpdateControl OBJECT-TYPE Writing value updateStart(4) commands the module to run a software update. The software image location and file name are specified in sWUpdateURL and sWUpdateFilename. Writing a updateIdle(1) when the update is running will terminate the update process immediately. Writing any value when no update is runnign has no effect. Reading this object returns either updateIdle(1), updateRunning(2) or updateFailed(3) depending on the status of the (last) software update. | 1.3.6.1.4.1.3715.99.2.3.2.1.1 | INTEGER {updateIdle(1), updateRunning(2), updateFailed(3), updateStart(4)} | read-write | optional |
| swUpdateURL OBJECT-TYPE The URL where the software image can be downloaded. Format e.g. TFTP:\\downloads\swupdate\. | 1.3.6.1.4.1.3715.99.2.3.2.1.2 | DisplayString | read-write | optional |
| sWUpdateFileName OBJECT-TYPE File name of the software image file to be downloaded. | 1.3.6.1.4.1.3715.99.2.3.2.1.3 | DisplayString | read-write | optional |
| sWUpdateStatus OBJECT-TYPE Description of the software update result. After successful update this object should return a string 'Software updated successfully on <date and time>'. If the update failed the returned value should be 'Software update failed'. | 1.3.6.1.4.1.3715.99.2.3.2.1.4 | DisplayString | read-only | optional |
| moduleRegistry OBJECT-IDENTITY | 1.3.6.1.4.1.3715.99.2.4 | |||
| moduleSizeOfTable OBJECT-TYPE This table defines maximum number of entries in the registry tables. All the registry tables have fixed size defined in this table. | 1.3.6.1.4.1.3715.99.2.4.1 | not-accessible | optional | |
| moduleSizeOfEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.4.1.1 | not-accessible | optional | |
| sizeOfRegistry OBJECT-TYPE Max number of entries in the registryTable. The entries in the registryTable are numbered from 1..sizeofRegistry. | 1.3.6.1.4.1.3715.99.2.4.1.1.1 | INTEGER | read-only | mandatory |
| sizeOfRepairlog OBJECT-TYPE Max number of entries in the repairlogTable. First entry (oldest entry) is deleted, when a new entry is added and the table is full. | 1.3.6.1.4.1.3715.99.2.4.1.1.2 | INTEGER | read-only | optional |
| sizeOfNotebook OBJECT-TYPE Max number of entries in the notebookTable. The lines in the notebookTable are numbered from 1..sizeofNotebook. | 1.3.6.1.4.1.3715.99.2.4.1.1.3 | INTEGER | read-only | optional |
| moduleRegistryTable OBJECT-TYPE This table lists user data for all modules installed inside the element. Table is indexed by the moduleId and regIndex. regIndex can have values 1..sizeofRegistry. A registryEntry is 'deleted' by setting its name to an empty string. | 1.3.6.1.4.1.3715.99.2.4.2 | not-accessible | optional | |
| moduleRegistryEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.4.2.1 | not-accessible | optional | |
| regIndex OBJECT-TYPE A second index to registryTable. Can have values 1..sizeofRegistryTable. | 1.3.6.1.4.1.3715.99.2.4.2.1.1 | INTEGER (1..255) | read-only | optional |
| regName OBJECT-TYPE Descriptive name for the parameter. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported. Writing empty string to this object removes it from the registryTable. | 1.3.6.1.4.1.3715.99.2.4.2.1.2 | DisplayString | read-write | optional |
| regValue OBJECT-TYPE Textual information describing the parameter information. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported. | 1.3.6.1.4.1.3715.99.2.4.2.1.3 | DisplayString | read-write | optional |
| moduleRepairLogTable OBJECT-TYPE This table contains repair history entries for modules in the element. The table is indexed with moduleId and repairLogDate. The table can have sizeofRepairlog number of entries. If this number is exceeded when writing a new entry, the oldest entry is deleted and and a new entry is added. | 1.3.6.1.4.1.3715.99.2.4.3 | not-accessible | optional | |
| moduleRepairLogEntry OBJECT-TYPE Row entry in RepairLogTable. Note that it uses double index: moduleId repairIndex. that uniquely identify each log entry. Rows for particular module exist only if there is row, that represents this module in the moduleTable. A row is 'deleted' by giving a date 0000-00-00. | 1.3.6.1.4.1.3715.99.2.4.3.1 | not-accessible | optional | |
| repairIndex OBJECT-TYPE Row number of the Repairlog entry. Can have values between 1..sizeOfRepairlog. This field is a second index to moduleRepairLogTable. | 1.3.6.1.4.1.3715.99.2.4.3.1.1 | INTEGER (1..32767) | read-only | optional |
| repairDate OBJECT-TYPE Date of this repair entry formatted as CCYY-MM-DD. | 1.3.6.1.4.1.3715.99.2.4.3.1.2 | DisplayString | read-write | optional |
| repairReasonCode OBJECT-TYPE Repair code for this entry. | 1.3.6.1.4.1.3715.99.2.4.3.1.3 | OCTET STRING (SIZE(4)) | read-write | optional |
| repairNameCode OBJECT-TYPE Repairer name code (initials) for this entry. | 1.3.6.1.4.1.3715.99.2.4.3.1.4 | OCTET STRING (SIZE(4)) | read-write | optional |
| repairComment OBJECT-TYPE Comment of the repair event. The agent is allowed to truncate the length of the comment, if it is too long to internal storage. | 1.3.6.1.4.1.3715.99.2.4.3.1.5 | DisplayString | read-write | optional |
| moduleNotebookTable OBJECT-TYPE Notebook is a free text area for manager or serviceman notes. It is divided into 50 character long character blocks or lines. Each line is an entry in the notebookTable. Indices are moduleName and lineNumber. A new line with the same lineNumber overwrites the old line. | 1.3.6.1.4.1.3715.99.2.4.4 | not-accessible | optional | |
| moduleNotebookEntry OBJECT-TYPE | 1.3.6.1.4.1.3715.99.2.4.4.1 | not-accessible | optional | |
| notebookLineNumber OBJECT-TYPE The line number of the notebookTextLine. The number must be in between 1..sizeofNotebook. inclusive. Numbers should be used consecutively. | 1.3.6.1.4.1.3715.99.2.4.4.1.1 | INTEGER (1..255) | read-only | optional |
| notebookLineText OBJECT-TYPE Text field for storing notes about the module. | 1.3.6.1.4.1.3715.99.2.4.4.1.2 | OCTET STRING (SIZE(0..50)) | read-write | optional |