MIBs Depot

TELESTE-COMMON-MIB

Registered at
1.3.6.1.4.1.3715.99.1
1.3.6.1.4.1.3715.99.2
Namespace
teleste
Source file
TELESTE-COMMON-MIB
Digest
sha256:99b12c5471b6371b142e83c0b6d85441d54278b19d0f1c1bbfce13b00bd114d3

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
TELESTE-ROOT-MIBDateAndTime, TPhysAddress, Uint16, common

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
TELESTE-COMMON-MIB
TELESTE-ROOT-MIB

Objects

NameOIDSyntaxAccessStatus
element
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.1
elementInformation
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.1.1
elementName
OBJECT-TYPE
This is the logical name of the controlling module of the network element. The name may or may not be the same as the module's name in the moduleTable.
1.3.6.1.4.1.3715.99.1.1.1DisplayStringread-writemandatory
elementStructure
OBJECT-TYPE
This object tells whether the device is a single compact device or a modular device.
1.3.6.1.4.1.3715.99.1.1.2INTEGER {unknown(1), compact(2), modular(3)}read-onlymandatory
elementConfigChangeCode
OBJECT-TYPE
This object is an indicator about changes in the network element configuration. How the value is formed is device dependent. It can be a counter, a checksum of the device configuration parameters, a DateAndTime type variable or even SysUptime, if no other information is available. DateAndTime is the recommended value. This object is intended to permit a management application to maintain configuration (including moduleTable) syncronization with the agent.
1.3.6.1.4.1.3715.99.1.1.3INTEGERread-onlyoptional
elementResetCount
OBJECT-TYPE
Total number of software resets during the device's life time.
1.3.6.1.4.1.3715.99.1.1.4INTEGERread-onlyoptional
elementTotalUpTime
OBJECT-TYPE
The total uptime the device (software) has been running. Unit 1 day.
1.3.6.1.4.1.3715.99.1.1.5INTEGERread-onlymandatory
elementLatitude
OBJECT-TYPE
Device latitude coordinate. Unit 0.00001 degrees.
1.3.6.1.4.1.3715.99.1.1.6INTEGERread-writeoptional
elementLongitude
OBJECT-TYPE
Device longitude coordinate. Unit 0.00001 degrees.
1.3.6.1.4.1.3715.99.1.1.7INTEGERread-writeoptional
elementAltitude
OBJECT-TYPE
Device altitude coordinate. Unit 1 metre.
1.3.6.1.4.1.3715.99.1.1.8INTEGERread-writeoptional
elementStatus
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.1.2
statusGeneral
OBJECT-TYPE
A number stating the general status of the element. Values: 1 = Normal 2 = At least one Notification is active 3 = At least one Warning is active 4 = At least one Alarm is active If the element has more than one state active, then the state with the highest value is returned.
1.3.6.1.4.1.3715.99.1.2.1INTEGER {normal(1), notification(2), warning(3), alarm(4)}read-onlymandatory
statusBusMaster
OBJECT-TYPE
A number stating the Bus Master status of the NE. Values: 1 = The NE is a slave-only device 2 = The NE is configured as slave 3 = The NE is configured as master but is currently slave because a stronger master is on the bus 4 = The NE is currently the bus master
1.3.6.1.4.1.3715.99.1.2.2INTEGER {slaveOnly(1), configuredSlave(2), currentlySlave(3), currentlyMaster(4)}read-onlyoptional
statusLmt
OBJECT-TYPE
A number telling if the Local Management Terminal (LMT) is connected to the element. Values: 1 = The element does not have an LMT interface 2 = The element can not detect if an LMT is connected 3 = The element has not detected a connected LMT 4 = The element has detected a connected LMT Note! Applies only to fysically point-to-point connected LMT's to device, not via bus ot other shared medias.
1.3.6.1.4.1.3715.99.1.2.3INTEGER {noLmtInterface(1), stateUnknown(2), notConnected(3), connected(4)}read-onlyoptional
statusLid
OBJECT-TYPE
Element lid status: 1 = no lid (no lid sensor is available) 2 = lid is closed 3 = lid is open
1.3.6.1.4.1.3715.99.1.2.4INTEGER {noLid(1), closed(2), open(3)}read-onlyoptional
statusTemperature
OBJECT-TYPE
Element temperature status: 1 = normal 2 = HIHI 3 = Hi 4 = Lo 5 = LOLO
1.3.6.1.4.1.3715.99.1.2.5INTEGER {tempNormal(1), tempHIHI(2), tempHi(3), tempLo(4), tempLOLO(5)}read-onlyoptional
statusFan
OBJECT-TYPE
A common status object for all fans in the device. fanNormal(1) = all fans operate normally fanFailure(2) = at least one fan has a failure
1.3.6.1.4.1.3715.99.1.2.6INTEGER {fanNormal(1), fanFailure(2)}read-onlymandatory
statusHardware
OBJECT-TYPE
Device hardware status: hwNormal(1) = the hardware operates normally hwFailure(2) = a hardware failure is detected
1.3.6.1.4.1.3715.99.1.2.7INTEGER {hwNormal(1), hwFailure(2)}read-onlymandatory
statusSoftware
OBJECT-TYPE
Device software status: swNormal(1) = the software operates normally swFailure(2) = a software failure is detected swMissing(3) = the software or firmware is missing sw(Initialising(4) = the software is initialising
1.3.6.1.4.1.3715.99.1.2.8INTEGER {swNormal(1), swFailure(2), swMissing(3), swInitialising(4)}read-onlymandatory
statusSettings
OBJECT-TYPE
Status of device settings: settingsStable(1) = settings are stable settingsChanged(2) = settings have been (recently) changed settingsNotAvailable(3) = settings status is not available The value should stay in value 2 only a predefined time, e.g. 60 seconds or the time it takes until the settings are written into non-volatile memory.
1.3.6.1.4.1.3715.99.1.2.9INTEGER {settingsStable(1), settingsChanged(2), settingsNotAvailable(3)}read-onlymandatory
elementControl
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.1.3
controlResetElement
OBJECT-TYPE
On write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On read requests value noReset(1) is returned.
1.3.6.1.4.1.3715.99.1.3.1INTEGER {noReset(1), hardReset(2), softReset(3)}read-writemandatory
controlBusMasterAdminState
OBJECT-TYPE
This object tells whether the element is configured as a bus master or not. Only relevant for bus master type of elements. Others return no(2).
1.3.6.1.4.1.3715.99.1.3.2INTEGER {master(1), slave(2)}read-writeoptional
controlAlarmDetection
OBJECT-TYPE
This variable is used to disable or enable the element alarm checking. When disabled(1), the element will not check any alarms (or send traps). Default value is enabled(2). Note: This variable must be consistent with commonAlarmDetectionControl in SCTE-HMS-COMMON-MIB, if that is implemented.
1.3.6.1.4.1.3715.99.1.3.3INTEGER {disabled(1), enabled(2), restart(3)}read-writemandatory
controlMaxNumberTrapReceivers
OBJECT-TYPE
Number of entries in the elementTrapReceiverTable. At least one trap entry must be supported.
1.3.6.1.4.1.3715.99.1.3.4INTEGERread-onlymandatory
controlTrapReceiverTable
OBJECT-TYPE
A table of manager trap receiver addresses, ports and communities. Total number of entries can not exceed elementNumberTrapReceivers. An entry is deleted from this table by setting its IP address to '0.0.0.0'. Note: one of the community strings must match to commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if that is implemented.
1.3.6.1.4.1.3715.99.1.3.5not-accessibleoptional
controlTrapReceiverEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.1.3.5.1not-accessibleoptional
receiverEntryId
OBJECT-TYPE
Unique table index. Makes possible to have several ip-address of 0.0.0.0 entries so that no mechanism for row manipulation of table is needed.
1.3.6.1.4.1.3715.99.1.3.5.1.1INTEGER (1..255)read-onlymandatory
receiverAddress
OBJECT-TYPE
Ip address of the manager receiving Traps.
1.3.6.1.4.1.3715.99.1.3.5.1.2IpAddressread-writemandatory
receiverPort
OBJECT-TYPE
Trap UDP port number. Default port is the standard trap port 162.
1.3.6.1.4.1.3715.99.1.3.5.1.3INTEGER (1..65535)read-writemandatory
receiverCommunity
OBJECT-TYPE
Community string for the trap receiver. The agent is allowed to limit the length of the string. Minimum length of eight characters must be supported. Note: one of the community strings must match to commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if that is implemented.
1.3.6.1.4.1.3715.99.1.3.5.1.4DisplayStringread-writemandatory
controlTrapSending
OBJECT-TYPE
Enables/disables trap sending. 1 = traps enabled 2 = traps disabled
1.3.6.1.4.1.3715.99.1.3.6INTEGER {enabled(1), disabled(2)}read-writeoptional
controlTrapInterval
OBJECT-TYPE
The minimum interval between traps. - Unit 10 milliseconds - Minimum value 0 (send as fast as possible) - Maximum value 1000 (10 seconds) - Default value is 100 (1 second)
1.3.6.1.4.1.3715.99.1.3.7INTEGERread-writeoptional
controlTrapLifeTime
OBJECT-TYPE
The maximum time a trap stays in the trap queue waiting for sending. - Unit 1 second. - Minimum value 10 - Maximum value 300 - Default value 60
1.3.6.1.4.1.3715.99.1.3.8INTEGERread-writeoptional
controlAlarmOnDelay
OBJECT-TYPE
The minimum time an object's alarm/warning condition must exist before it is recorded as an alarm/warning. Common to all alarms/warnings - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 100 (1 second)
1.3.6.1.4.1.3715.99.1.3.9INTEGERread-writeoptional
controlAlarmOffDelay
OBJECT-TYPE
The minimum time an alarm/warning entry stays active after the object has reached it's normal condition. Common to all alarms/warnings. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - default value 100 (1 second)
1.3.6.1.4.1.3715.99.1.3.10INTEGERread-writeoptional
controlTrapDelay
OBJECT-TYPE
The time before a trap is sent after an alarm is detected. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 500 (5 seconds) This parameter can be used to control alarm storms e.g. in an amplifier cascade by using a different value in each amplifier.
1.3.6.1.4.1.3715.99.1.3.11INTEGERread-writeoptional
elementProductKey
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.1.4
productKeyNumberOfKeys
OBJECT-TYPE
Number of product keys supported by the device.
1.3.6.1.4.1.3715.99.1.4.4INTEGERread-onlyoptional
productKeyTable
OBJECT-TYPE
1.3.6.1.4.1.3715.99.1.4.5not-accessiblemandatory
productKeyEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.1.4.5.1not-accessiblemandatory
productKeyIndex
OBJECT-TYPE
Product key index.
1.3.6.1.4.1.3715.99.1.4.5.1.1INTEGER (1..16)read-onlymandatory
productKeyValue
OBJECT-TYPE
Product key value.
1.3.6.1.4.1.3715.99.1.4.5.1.2OCTET STRINGread-writemandatory
productKeyMask
OBJECT-TYPE
Product key mask.
1.3.6.1.4.1.3715.99.1.4.5.1.3OCTET STRINGread-onlymandatory
productKeyStatus
OBJECT-TYPE
Product key status: 1(keyInvalid) = the key is invalid or missing 2(keyValid) = the key is valid
1.3.6.1.4.1.3715.99.1.4.5.1.4INTEGER {keyInvalid(1), keyValid(2)}read-onlymandatory
productKeyCipher
OBJECT-TYPE
Cipher method supported by this key: 1(cipherOther) = other ciphering is used 2(cipherBlowFish) = BlowFish ciphering is used 3(cipherXXTEA) = XXTEA ciphering is used
1.3.6.1.4.1.3715.99.1.4.5.1.5INTEGER {cipherOther(1), cipherBlowFish(2), cipherXXTEA(3)}read-onlymandatory
productKeyNumberOfFeatures
OBJECT-TYPE
Number of features available with this key.
1.3.6.1.4.1.3715.99.1.4.5.1.6INTEGERread-onlymandatory
productKeyFeatureTable
OBJECT-TYPE
1.3.6.1.4.1.3715.99.1.4.6not-accessiblemandatory
productKeyFeatureEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.1.4.6.1not-accessiblemandatory
productKeyFeatureIndex
OBJECT-TYPE
Feature index (second index).
1.3.6.1.4.1.3715.99.1.4.6.1.1INTEGER (1..32)read-onlymandatory
productKeyFeatureName
OBJECT-TYPE
A human-readable description of the feature.
1.3.6.1.4.1.3715.99.1.4.6.1.2OCTET STRINGread-onlymandatory
productKeyFeatureEnable
OBJECT-TYPE
Status of the feature: 1(featureDisable) = the feature si disabled in this device 2(featureEnable) = the feature is enabled in this devices
1.3.6.1.4.1.3715.99.1.4.6.1.3INTEGER {featureDisable(1), featureEnable(2)}read-onlymandatory
productKeyFeatureExpirationTime
OBJECT-TYPE
Number of days left before the feature expires. A zero value means infinite validity time. This object has a meaning only if the feature is enabled (productKeyFeatureEnable = 2(featureEnable)).
1.3.6.1.4.1.3715.99.1.4.6.1.4INTEGERread-onlymandatory
module
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.2
moduleInformation
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.2.1
moduleTable
OBJECT-TYPE
This table lists basic module identification and configuration data of modules installed inside the managed element. The first row in the table list information about the element itself. If the element is not modular, only the first row exists in the table. Object moduleId is used for indexing the modules in all module section tables.
1.3.6.1.4.1.3715.99.2.1.1not-accessiblemandatory
moduleEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.1.1.1not-accessiblemandatory
moduleId
OBJECT-TYPE
An unique module index identifying the (physical) modules inside the network element. The exact conjunction between the index and the physical modules depends on the element structural principle. For network elements containing plug-in modules the index should follow module slot numbering. This index should be used in all subsequent module tables.
1.3.6.1.4.1.3715.99.2.1.1.1.1INTEGER (1..65535)read-onlymandatory
moduleName
OBJECT-TYPE
The identification name ('aliasname') of the module.
1.3.6.1.4.1.3715.99.2.1.1.1.2DisplayStringread-writeoptional
moduleHwType
OBJECT-TYPE
The hardware type name of the module.
1.3.6.1.4.1.3715.99.2.1.1.1.3DisplayStringread-onlymandatory
moduleRackNo
OBJECT-TYPE
Rack number of the module. This can be used to identify the physical position of the module in the case where the agent manages modules that are in several racks.
1.3.6.1.4.1.3715.99.2.1.1.1.4INTEGERread-writeoptional
moduleSlotNo
OBJECT-TYPE
Slot number of the module (within rack).
1.3.6.1.4.1.3715.99.2.1.1.1.5INTEGERread-writeoptional
moduleDetailTable
OBJECT-TYPE
This table lists detailed module data of modules installed inside the element. The first row in the table list information about the element itself. If the element is not modular, only the first row exists in the table.
1.3.6.1.4.1.3715.99.2.1.2not-accessiblemandatory
moduleDetailEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.1.2.1not-accessiblemandatory
moduleMacAddress
OBJECT-TYPE
Module MAC address. If the MAC address is unknown '00.00.00.00.00.00' is returned.
1.3.6.1.4.1.3715.99.2.1.2.1.1TPhysAddressread-onlyoptional
moduleBusAddress
OBJECT-TYPE
Module bus address.
1.3.6.1.4.1.3715.99.2.1.2.1.2INTEGERread-onlyoptional
moduleAppDate
OBJECT-TYPE
Module application software date.
1.3.6.1.4.1.3715.99.2.1.2.1.3DateAndTimeread-onlymandatory
moduleAppVersion
OBJECT-TYPE
Module application software version. If software version is undefined, then zero length string is returned.
1.3.6.1.4.1.3715.99.2.1.2.1.4DisplayStringread-onlymandatory
moduleBiosDate
OBJECT-TYPE
Module BIOS date.
1.3.6.1.4.1.3715.99.2.1.2.1.5DateAndTimeread-onlymandatory
moduleBiosVersion
OBJECT-TYPE
Module BIOS version. If bios version is undefined, a zero length string is returned.
1.3.6.1.4.1.3715.99.2.1.2.1.6DisplayStringread-onlymandatory
moduleHwSerialNumber
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.3715.99.2.1.2.1.7DisplayStringread-onlymandatory
moduleHwVersion
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.3715.99.2.1.2.1.8DisplayStringread-onlymandatory
moduleStatus
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.2.2
moduleStatusTable
OBJECT-TYPE
This table contains status objects for modules inside the network element.The first row in the table lists information about the host module. If the element is not modular, only the first row exists in the table.
1.3.6.1.4.1.3715.99.2.2.1not-accessiblemandatory
moduleStatusEntry
OBJECT-TYPE
Row in moduleStatusTable. The index is moduleId from the moduleTable. Row in this table exist only if there is a row with the same moduleId in the moduleTable.
1.3.6.1.4.1.3715.99.2.2.1.1not-accessiblemandatory
statusResetCause
OBJECT-TYPE
Reason for the last reset. If the reason is unknown, the value is reasonUnknown(1). If the device makes self reset and it can detect it, then value is reasonSelfReset(2). If the reset was made by the user from the power switch and it can be sensed, then the value is reasonPowerReset(3). If the reason is an external command from the user interface or from the network message (e.g. commonReset), then the reason is reasonCommandedReset(4).
1.3.6.1.4.1.3715.99.2.2.1.1.1INTEGER {unknown(1), selfReset(2), powerReset(3), commandedReset(4), softdownloadReset(5)}read-onlymandatory
statusRunningSwImage
OBJECT-TYPE
Currently running software image number. Bios is 0, applications are numbered from 1..n, where n is the maximum image number.
1.3.6.1.4.1.3715.99.2.2.1.1.2INTEGERread-onlymandatory
statusInternalTemperature
OBJECT-TYPE
Device temperature, unit 0.1 deg C. Value is zero (0), if temperature is not available.
1.3.6.1.4.1.3715.99.2.2.1.1.3INTEGER (-600..1300)read-onlymandatory
statusLidStatus
OBJECT-TYPE
Current lid status detected by the device. May or may not be the same variable as the elementLidStatus.
1.3.6.1.4.1.3715.99.2.2.1.1.4INTEGER {noLid(1), closed(2), open(3)}read-onlyoptional
statusRestartCounter
OBJECT-TYPE
This objects counts the number of restarts of the module. A start can be a cold start or a warm start.
1.3.6.1.4.1.3715.99.2.2.1.1.5Counterread-onlyoptional
moduleControl
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.2.3
moduleControlTable
OBJECT-TYPE
This table contains common control commands for all the modules inside the element.
1.3.6.1.4.1.3715.99.2.3.1not-accessibleoptional
moduleControlEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.3.1.1not-accessibleoptional
controlLedUsage
OBJECT-TYPE
A variable to instruct how device LED's behave when the lid is closed.
1.3.6.1.4.1.3715.99.2.3.1.1.1INTEGER {notSupported(1), alwaysOn(2), offWhenLidClosed(3)}read-writeoptional
controlMarkState
OBJECT-TYPE
A variable to instruct the device to start and stop showing mark (blinking module LED). On read requests returns the current mark state.
1.3.6.1.4.1.3715.99.2.3.1.1.2INTEGER {notSupported(1), on(2), off(3)}read-writeoptional
controlReset
OBJECT-TYPE
On write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On read requests value noReset(1) is returned.
1.3.6.1.4.1.3715.99.2.3.1.1.3INTEGER {noReset(1), hardReset(2), softReset(3)}read-writeoptional
controlTempLimitHiHi
OBJECT-TYPE
Module temperature HiHi (high alarm) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.4INTEGERread-writeoptional
controlTempLimitHi
OBJECT-TYPE
Module temperature Hi (high warning) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.5INTEGERread-writeoptional
controlTempLimitLo
OBJECT-TYPE
Module temperature Lo (low warning) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.7INTEGERread-writeoptional
controlTempLimitLoLo
OBJECT-TYPE
Module temperature LoLo (low alarm) limit in 0.1 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.8INTEGERread-writeoptional
controlTempDeadBand
OBJECT-TYPE
Module temperature alarm/warning deadband in 0.1 degC. Common to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines the difference between the 'ON' limit and the 'OFF' limit of the corresponding alarm. Example: The Hi limit is 65 degC and the deadband is 5 degC. The high warning is activated when the temperature exceeds 65 degC and deactivated only after it falls below 60 degC.
1.3.6.1.4.1.3715.99.2.3.1.1.9INTEGERread-writeoptional
controlInternalAppAccess
OBJECT-TYPE
This object defines whether the internal controller application is able to access the module parameters. This corresponds to the BXX module setting 'Allow Functions'. 1 = allow internal control 2 = deny internal control (remote control is possible)
1.3.6.1.4.1.3715.99.2.3.1.1.10INTEGER {allowIntControl(1), denyIntControl(2)}read-writeoptional
controlLocalAccess
OBJECT-TYPE
This object defines whether the local user interface (buttons, knobs etc.) is enabled or disabled. Values: 1 = disabled, local UI is locked 2 = enabled, local UI is active For modules/devices with no local UI this objects should return value 'disabled (1).
1.3.6.1.4.1.3715.99.2.3.1.1.11INTEGER {disabled(1), enabled(2)}read-writeoptional
moduleSWUpdateTable
OBJECT-TYPE
A table of software update control objects.
1.3.6.1.4.1.3715.99.2.3.2not-accessibleoptional
moduleSWUpdateEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.3.2.1not-accessibleoptional
sWUpdateControl
OBJECT-TYPE
Writing value updateStart(4) commands the module to run a software update. The software image location and file name are specified in sWUpdateURL and sWUpdateFilename. Writing a updateIdle(1) when the update is running will terminate the update process immediately. Writing any value when no update is runnign has no effect. Reading this object returns either updateIdle(1), updateRunning(2) or updateFailed(3) depending on the status of the (last) software update.
1.3.6.1.4.1.3715.99.2.3.2.1.1INTEGER {updateIdle(1), updateRunning(2), updateFailed(3), updateStart(4)}read-writeoptional
swUpdateURL
OBJECT-TYPE
The URL where the software image can be downloaded. Format e.g. TFTP:\\downloads\swupdate\.
1.3.6.1.4.1.3715.99.2.3.2.1.2DisplayStringread-writeoptional
sWUpdateFileName
OBJECT-TYPE
File name of the software image file to be downloaded.
1.3.6.1.4.1.3715.99.2.3.2.1.3DisplayStringread-writeoptional
sWUpdateStatus
OBJECT-TYPE
Description of the software update result. After successful update this object should return a string 'Software updated successfully on <date and time>'. If the update failed the returned value should be 'Software update failed'.
1.3.6.1.4.1.3715.99.2.3.2.1.4DisplayStringread-onlyoptional
moduleRegistry
OBJECT-IDENTITY
1.3.6.1.4.1.3715.99.2.4
moduleSizeOfTable
OBJECT-TYPE
This table defines maximum number of entries in the registry tables. All the registry tables have fixed size defined in this table.
1.3.6.1.4.1.3715.99.2.4.1not-accessibleoptional
moduleSizeOfEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.4.1.1not-accessibleoptional
sizeOfRegistry
OBJECT-TYPE
Max number of entries in the registryTable. The entries in the registryTable are numbered from 1..sizeofRegistry.
1.3.6.1.4.1.3715.99.2.4.1.1.1INTEGERread-onlymandatory
sizeOfRepairlog
OBJECT-TYPE
Max number of entries in the repairlogTable. First entry (oldest entry) is deleted, when a new entry is added and the table is full.
1.3.6.1.4.1.3715.99.2.4.1.1.2INTEGERread-onlyoptional
sizeOfNotebook
OBJECT-TYPE
Max number of entries in the notebookTable. The lines in the notebookTable are numbered from 1..sizeofNotebook.
1.3.6.1.4.1.3715.99.2.4.1.1.3INTEGERread-onlyoptional
moduleRegistryTable
OBJECT-TYPE
This table lists user data for all modules installed inside the element. Table is indexed by the moduleId and regIndex. regIndex can have values 1..sizeofRegistry. A registryEntry is 'deleted' by setting its name to an empty string.
1.3.6.1.4.1.3715.99.2.4.2not-accessibleoptional
moduleRegistryEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.4.2.1not-accessibleoptional
regIndex
OBJECT-TYPE
A second index to registryTable. Can have values 1..sizeofRegistryTable.
1.3.6.1.4.1.3715.99.2.4.2.1.1INTEGER (1..255)read-onlyoptional
regName
OBJECT-TYPE
Descriptive name for the parameter. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported. Writing empty string to this object removes it from the registryTable.
1.3.6.1.4.1.3715.99.2.4.2.1.2DisplayStringread-writeoptional
regValue
OBJECT-TYPE
Textual information describing the parameter information. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported.
1.3.6.1.4.1.3715.99.2.4.2.1.3DisplayStringread-writeoptional
moduleRepairLogTable
OBJECT-TYPE
This table contains repair history entries for modules in the element. The table is indexed with moduleId and repairLogDate. The table can have sizeofRepairlog number of entries. If this number is exceeded when writing a new entry, the oldest entry is deleted and and a new entry is added.
1.3.6.1.4.1.3715.99.2.4.3not-accessibleoptional
moduleRepairLogEntry
OBJECT-TYPE
Row entry in RepairLogTable. Note that it uses double index: moduleId repairIndex. that uniquely identify each log entry. Rows for particular module exist only if there is row, that represents this module in the moduleTable. A row is 'deleted' by giving a date 0000-00-00.
1.3.6.1.4.1.3715.99.2.4.3.1not-accessibleoptional
repairIndex
OBJECT-TYPE
Row number of the Repairlog entry. Can have values between 1..sizeOfRepairlog. This field is a second index to moduleRepairLogTable.
1.3.6.1.4.1.3715.99.2.4.3.1.1INTEGER (1..32767)read-onlyoptional
repairDate
OBJECT-TYPE
Date of this repair entry formatted as CCYY-MM-DD.
1.3.6.1.4.1.3715.99.2.4.3.1.2DisplayStringread-writeoptional
repairReasonCode
OBJECT-TYPE
Repair code for this entry.
1.3.6.1.4.1.3715.99.2.4.3.1.3OCTET STRING (SIZE(4))read-writeoptional
repairNameCode
OBJECT-TYPE
Repairer name code (initials) for this entry.
1.3.6.1.4.1.3715.99.2.4.3.1.4OCTET STRING (SIZE(4))read-writeoptional
repairComment
OBJECT-TYPE
Comment of the repair event. The agent is allowed to truncate the length of the comment, if it is too long to internal storage.
1.3.6.1.4.1.3715.99.2.4.3.1.5DisplayStringread-writeoptional
moduleNotebookTable
OBJECT-TYPE
Notebook is a free text area for manager or serviceman notes. It is divided into 50 character long character blocks or lines. Each line is an entry in the notebookTable. Indices are moduleName and lineNumber. A new line with the same lineNumber overwrites the old line.
1.3.6.1.4.1.3715.99.2.4.4not-accessibleoptional
moduleNotebookEntry
OBJECT-TYPE
1.3.6.1.4.1.3715.99.2.4.4.1not-accessibleoptional
notebookLineNumber
OBJECT-TYPE
The line number of the notebookTextLine. The number must be in between 1..sizeofNotebook. inclusive. Numbers should be used consecutively.
1.3.6.1.4.1.3715.99.2.4.4.1.1INTEGER (1..255)read-onlyoptional
notebookLineText
OBJECT-TYPE
Text field for storing notes about the module.
1.3.6.1.4.1.3715.99.2.4.4.1.2OCTET STRING (SIZE(0..50))read-writeoptional