MIBs Depot

TAIT-INFRA93SERIES-MIB

Registered at
1.3.6.1.4.1.3570.1.1.10.2
1.3.6.1.4.1.3570.2.2
Last updated
2019-08-30 15:38
Organization
www.taitradio.com
Revisions
2019-08-30 15:38, 2019-05-29 00:00, 2019-03-30 00:00, 2018-08-30 00:00, 2018-07-30 00:00, 2018-05-22 00:26, 2017-09-14 01:30, 2017-08-24 14:00, 2017-05-05 15:00, 2017-03-07 00:00, 2017-02-03 00:00, 2016-12-05 00:00, 2016-07-01 00:00, 2016-02-18 00:00, 2015-11-03 04:00, 2015-03-23 04:00, 2014-10-30 15:00, 2014-07-29 00:00, 2014-07-10 00:00, 2014-04-14 00:00, 2014-04-13 00:00, 2014-03-14 00:00, 2014-01-26 00:00, 2014-01-14 11:00, 2014-01-01 00:00
Namespace
tait
Source file
TAIT-INFRA93SERIES-MIB
Digest
sha256:3087d2adc047d5df848f5e0517a97edfe2899945cd4d79e75157f546d6d02f92

Description

rctRfTransmitter, rctRfReceiver, rctSelectedChannel related Monitored values in the TB93XX series Base Stations

Contact

Tait Communications 245 Wooldridge Road PO Box 1645 Christchurch New Zealand phone: +64 3358 3399 email: support@taitradio.com

Imports

FromSymbols
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue
TAIT-COMMON-MIBtaitGeneric
TAIT-INFRA93-94SERIES-COMMON-MIBinfra93-94MibModule
TAIT-INFRA93-94SERIES-TC-MIBAlarmState, BaseStationMode, ChannelGroupStatus, Condition, CurrentmA, FrequencyHz, GateState, Milliseconds, OptionState, PowerW, TimingControlType, TransmitterStatus, VoltageV
TAIT-INFRA93SERIES-TC-MIBColourCode, ControlProtocolStatus, DcsCode, FallbackNodeStatus, FrequencydHz, LeveldBm, LogicalChannelState, MPTControlProtocolStatus, OperationalMode, Ratio, ReceiverSyncStatus, RxFrequencyResponse, SINADLevel, StandaloneNodeStatus, SubAudibleType, Temperature, TransmitterSyncStatus, TxFrequencyResponse

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
TAIT-COMMON-MIB
TAIT-INFRA93-94SERIES-COMMON-MIB
TAIT-INFRA93-94SERIES-TC-MIB
TAIT-INFRA93SERIES-MIB
TAIT-INFRA93SERIES-TC-MIB

Objects

NameOIDSyntaxAccessStatus
infra93MIB
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2
monitored
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2
mibObjects
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1
productInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.1
productSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.1.1
info
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.1.1.1
infoTransmitterStatus
OBJECT-TYPE
The current status of the transmitter. unknown(0): The transmitter is in an unknown, probably faulty state. unconfigured(1): The transmitter requires configuration before it can transmit. untuned(2): Something is wrong with the configuration, so the exciter is unable to set the selected frequency. idle(3): The transmitter is not transmitting on either channel. transmitting(4): The transmitter is actively transmitting. calibrating(5): The transmitter is being calibrated. fault(6): There is a detected fault with the transmitter.
1.3.6.1.4.1.3570.2.2.2.1.1.1.1.1TransmitterStatusread-onlycurrent
infoStandaloneNodeStatus
OBJECT-TYPE
The current status of standalone mode. offline(0): A maintainer has taken the base station offline. The base station is not under node control. standby(1): The standalone node is enabled and ready to become active if the base station loses contact with the node. The standby state can also occur if the base station has lost contact with the node, but an activated major alarm at the base station prevents the standalone node from becoming active. active(2): The base station has lost connection with the node and is in standalone node mode. disabled(4): The standalone node feature is disabled in configuration. running(5): The standalone node is contending with other embedded nodes on the site to take over as the master node. master(6): The standalone node is acting as a master node and has set up a control channel on this base station.
1.3.6.1.4.1.3570.2.2.2.1.1.1.1.2StandaloneNodeStatusread-onlydeprecated
infoMPTFallbackNodeStatus
OBJECT-TYPE
The current status of the MPT fallback node.
1.3.6.1.4.1.3570.2.2.2.1.1.1.1.3FallbackNodeStatusread-onlycurrent
infoDMRFallbackNodeStatus
OBJECT-TYPE
The current status of the DMR fallback node.
1.3.6.1.4.1.3570.2.2.2.1.1.1.1.4FallbackNodeStatusread-onlycurrent
health
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.1.1.2
healthRunMode
OBJECT-TYPE
Indicates the current base station mode. Offline means that a maintainer has taken the base station out of service. offline(0): The base station is currently offline. It is out of service. It does not transmit or receive user traffic. It communicates with a web browser but not with nodes. online(1): The base station is currently online. This is its normal operating mode. unknown(2): The base station mode is unknown. This indicates a faulty condition.
1.3.6.1.4.1.3570.2.2.2.1.1.1.2.2BaseStationModeread-onlycurrent
healthNetworkConnLogChan1State
OBJECT-TYPE
Indicates the state of logical channel 1. inactive(0): The logical channel is not transmitting. idle(1): The logical channel is currently idle. It is not currently a traffic channel or a control channel. traffic(2): The logical channel is currently operating as a traffic channel (voice/data). control(3): The logical channel is currently operating as a control channel. test(4): The logical channel is currently operating as a test channel. poll(5): The logical channel is currently operating as a poll channel. invalid(255): The logical channel configuration is invalid.
1.3.6.1.4.1.3570.2.2.2.1.1.1.2.3LogicalChannelStateread-onlycurrent
healthNetworkConnLogChan2State
OBJECT-TYPE
Indicates the state of logical channel 2. inactive(0): The logical channel is not transmitting. idle(1): The logical channel is currently idle. It is not currently a traffic channel or a control channel. traffic(2): The logical channel is currently operating as a traffic channel (voice/data). control(3): The logical channel is currently operating as a control channel. test(4): The logical channel is currently operating as a test channel. poll(5): The logical channel is currently operating as a poll channel. invalid(255): The logical channel configuration is invalid.
1.3.6.1.4.1.3570.2.2.2.1.1.1.2.4LogicalChannelStateread-onlycurrent
healthSecureShellRunning
OBJECT-TYPE
Indicates whether the remote secure shell interface is running. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.1.2.5TruthValueread-onlycurrent
productEnabledFeatures
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.1.2
licenceDmrFull
OBJECT-TYPE
DMR Full license. The base station is licensed for operation on a DMR Full system. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.300TruthValueread-onlycurrent
licenceAnalogConventional
OBJECT-TYPE
Analog Conventional licence. The base station is licenced for Analog conventional operation Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.301TruthValueread-onlycurrent
licenceDmrExpress
OBJECT-TYPE
DMR Express 6 license. The base station is licensed for operation on a DMR Express system. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.302TruthValueread-onlycurrent
licenceDmrAccess
OBJECT-TYPE
DMR Access license. The base station is licensed for operation on a DMR Access system. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.303TruthValueread-onlycurrent
licenceDmrConventional
OBJECT-TYPE
DMR Conventional license. The base station is licensed for operation on a DMR concentional system. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.304TruthValueread-onlycurrent
licenceDmrExpress20
OBJECT-TYPE
DMR Express 20 license. The base station is licensed for operation on a DMR Express 20 system. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.305TruthValueread-onlycurrent
licenceDmrCentralVoter
OBJECT-TYPE
DMR Central Voter license. The base station is licensed for operation as a DMR Central Voter. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.306TruthValueread-onlycurrent
licenceDmrNetworkSatellite
OBJECT-TYPE
DMR IP Networking Satellite license. The base station is licensed for operation as a DMR IP Networking satellite. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.1.2.307TruthValueread-onlycurrent
modules
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2
reciter
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2
rctSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.1
rctInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.1.1
rctInfoProductCode
OBJECT-TYPE
The reciter product code. Product codes are explained in the Specifications Manual.
1.3.6.1.4.1.3570.2.2.2.1.2.2.1.1.1SnmpAdminStringread-onlycurrent
rctInfoSerialNumber
OBJECT-TYPE
The reciter serial number. A unique identifier assigned to the module in the factory.
1.3.6.1.4.1.3570.2.2.2.1.2.2.1.1.2SnmpAdminStringread-onlycurrent
rctInfoHardwareVersion
OBJECT-TYPE
The reciter hardware version number.
1.3.6.1.4.1.3570.2.2.2.1.2.2.1.1.3SnmpAdminStringread-onlycurrent
rctInfoFirmwareVersion
OBJECT-TYPE
The version number of the firmware currently installed on the Reciter.
1.3.6.1.4.1.3570.2.2.2.1.2.2.1.1.4SnmpAdminStringread-onlycurrent
rctHealth
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.1.2
rctSelectedChannel
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.2
rctSelectedChannelNumber
OBJECT-TYPE
Number of the currently selected channel. Range: 1..1000
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.1Unsigned32read-onlycurrent
rctSelectedChannelName
OBJECT-TYPE
Name of the current channel.
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.2SnmpAdminStringread-onlycurrent
rctSelectedChannelProfileName
OBJECT-TYPE
Name of the channel profile assigned to the currently selected channel.
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.3SnmpAdminStringread-onlycurrent
rctSelectedChannelSigProfileName
OBJECT-TYPE
Name of the signalling profile assigned to the currently selected channel.
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.4SnmpAdminStringread-onlycurrent
rctSelectedChannelTransmitPower
OBJECT-TYPE
Configured PA RF transmit power in watts for the current channel when it is powered by mains. Range: 0..100
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.5PowerWread-onlycurrent
rctSelectedChannelTxFreq
OBJECT-TYPE
The transmit frequency of the current channel in Hz. Range: 100000000..1000000000
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.6FrequencyHzread-onlycurrent
rctSelectedChannelRxFreq
OBJECT-TYPE
The receive frequency of the current channel in Hz. Range: 100000000..1000000000
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.7FrequencyHzread-onlycurrent
rctSelectedChannelSystemType
OBJECT-TYPE
The type of network configured in the channel profile of the currently selected channel, analogConventional(1), dmrConventional(2), dmrTrunking(3), mptTrunking(4)
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.10OperationalModeread-onlycurrent
rctSelectedChannelColourCode
OBJECT-TYPE
The configured colour code for the currently selected channel
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.11ColourCoderead-onlycurrent
rctSelectedChannelGroupName
OBJECT-TYPE
Name of the channel group assigned to the currently selected channel.
1.3.6.1.4.1.3570.2.2.2.1.2.2.2.12SnmpAdminStringread-onlycurrent
rctRfReceiveQuality
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.3
rctRfRcvInterference
OBJECT-TYPE
Interference level is above configured RSSI threshold. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.3.2TruthValueread-onlycurrent
rctRfInterferenceCounter
OBJECT-TYPE
Counter indicating cumulative number of seconds that interference has been present. Range: 0..4294967295
1.3.6.1.4.1.3570.2.2.2.1.2.2.3.3Counter32read-onlycurrent
rctRfInterferenceEvents
OBJECT-TYPE
The number of times the receiver detects interference.
1.3.6.1.4.1.3570.2.2.2.1.2.2.3.4Counter32read-onlycurrent
rctRfReceiver
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.4
rctRfReceiverRSSI
OBJECT-TYPE
The current strength of the received signal in dBm. Range: -12000..-6000
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.1LeveldBmread-onlycurrent
rctRfReceiverLC1RSSI
OBJECT-TYPE
The current strength of the received signal on logical channel 1 in dBm. Range: -12000..-6000
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.2LeveldBmread-onlycurrent
rctRfReceiverLC2RSSI
OBJECT-TYPE
The current strength of the received signal on logical channel 2 in dBm. Range: -12000..-6000
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.3LeveldBmread-onlycurrent
rctRfReceiverLC1RxGateState
OBJECT-TYPE
Receiver gate state of logical channel 1. Only valid if the logical channel has received anything since powering up. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.4TruthValueread-onlycurrent
rctRfReceiverLC2RxGateState
OBJECT-TYPE
Receiver gate state of logical channel 2. Only valid if the logical channel has received anything since powering up. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.5TruthValueread-onlycurrent
rctRfReceiverSelectedDecodeCTCSS
OBJECT-TYPE
The CTCSS value that the base station unmutes to.
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.8FrequencydHzread-onlycurrent
rctRfReceiverSelectedDecodeSubAudibleType
OBJECT-TYPE
The configured receive sub-audible signaling type.
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.9SubAudibleTyperead-onlycurrent
rctRfReceiverSelectedSINADGatingLevel
OBJECT-TYPE
The configured signal-to-noise gating threshold in dB.
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.10SINADLevelread-onlycurrent
rctRfReceiverSelectedDecodeDCS
OBJECT-TYPE
The DCS value that the base station unmutes to.
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.11DcsCoderead-onlycurrent
rctRfReceiverSelectedFrequencyResponse
OBJECT-TYPE
Specifies the receive baseband frequency response that applies to the channel. MPT Control channels have a flat speech charactieristic. MPT Traffic channels have a de-emphasis characteristic. Conventional analog channels take their setting from channel profile configuration. 'Flat speech' applies a constant gain to frequencies in the speech band (high pass above 300 Hz). 'De-emph speech' is a de-emphasis characteristic over the speech band (high pass above 300 Hz).
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.12RxFrequencyResponseread-onlycurrent
rctRfReceiverAnalogGateState
OBJECT-TYPE
Analog receiver gate state of the channel. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.13TruthValueread-onlycurrent
rctRfReceiverIsDisabled
OBJECT-TYPE
Status of the receiver; if it is unavailable then the receiver can't be disabled in the current mode of operation. Range: true(1), false(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.4.14TruthValueread-onlycurrent
rctRfTransmitter
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.5
rctRfTxSelectedEncodeCTCSS
OBJECT-TYPE
The configured transmit CTCSS tone frequency in dHz.
1.3.6.1.4.1.3570.2.2.2.1.2.2.5.10FrequencydHzread-onlycurrent
rctRfTxSelectedEncodeSubAudibleType
OBJECT-TYPE
The configured transmit sub-audible signaling type
1.3.6.1.4.1.3570.2.2.2.1.2.2.5.11SubAudibleTyperead-onlycurrent
rctRfTxSelectFrequencyResponse
OBJECT-TYPE
Specifies the transmit baseband frequency response that applies to the channel. MPT Control channels have a flat speech charactieristic. MPT Traffic channels have a pre-emphasis characteristic. Conventional analog channels take their setting from channel profile configuration. 'Flat speech' applies a constant gain to frequencies in the speech band (high pass above 300 Hz). 'Pre-emph speech' is a pre-emphasis characteristic over the speech band (high pass above 300 Hz).
1.3.6.1.4.1.3570.2.2.2.1.2.2.5.12TxFrequencyResponseread-onlycurrent
rctRfTxSelectedEncodeDCS
OBJECT-TYPE
The DCS sub-audible signalling value that the base station applies while transmitting.
1.3.6.1.4.1.3570.2.2.2.1.2.2.5.13DcsCoderead-onlycurrent
rctRfTxSelectedEncodeSubAudibleDeviation
OBJECT-TYPE
The deviation that CTCSS or DCS signaling will cause to the carrier frequency. It is in Hz.
1.3.6.1.4.1.3570.2.2.2.1.2.2.5.14Unsigned32read-onlycurrent
rctRfTxRfRepeatState
OBJECT-TYPE
The current RF repeat state. disabled(0): RF is not repeated. The reciter acts as a base station. enabled(1): RF is repeated. The reciter acts as a repeater.
1.3.6.1.4.1.3570.2.2.2.1.2.2.5.16OptionStateread-onlycurrent
rctTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.6
rctTemperatureBoard
OBJECT-TYPE
The reciter temperature in degrees Celsius, measured on the reciter circuit board. Range: -30..125
1.3.6.1.4.1.3570.2.2.2.1.2.2.6.1Temperatureread-onlycurrent
rctSystemInterface
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.2.7
rctSiConfiguredBalancedLineInLevel
OBJECT-TYPE
The configured level of the balanced line input in dBm. Range: -30..0
1.3.6.1.4.1.3570.2.2.2.1.2.2.7.1LeveldBmread-onlycurrent
rctSiConfiguredBalancedLineOutLevel
OBJECT-TYPE
The configured level of the balanced line output in dBm. Range: -30..0
1.3.6.1.4.1.3570.2.2.2.1.2.2.7.2LeveldBmread-onlycurrent
rctSiTxKey
OBJECT-TYPE
The state of the Tx key input. Range: Active(1), Inactive(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.7.3GateStateread-onlycurrent
rctSiRxGate
OBJECT-TYPE
The state of the Rx Gate output. Range: Active(1), Inactive(2)
1.3.6.1.4.1.3570.2.2.2.1.2.2.7.4GateStateread-onlycurrent
powerAmplifier
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3
paSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3.1
paInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3.1.1
paInfoProductCode
OBJECT-TYPE
The power amplifier product code. Product codes are explained in the Specifications Manual.
1.3.6.1.4.1.3570.2.2.2.1.2.3.1.1.1SnmpAdminStringread-onlycurrent
paInfoSerialNumber
OBJECT-TYPE
Power amplifier serial number. A unique identifier assigned to the module in the factory.
1.3.6.1.4.1.3570.2.2.2.1.2.3.1.1.2SnmpAdminStringread-onlycurrent
paInfoHardwareVersion
OBJECT-TYPE
The power amplifier hardware version number.
1.3.6.1.4.1.3570.2.2.2.1.2.3.1.1.3SnmpAdminStringread-onlycurrent
paInfoFirmwareVersion
OBJECT-TYPE
The version number of the firmware currently installed on the power amplifier.
1.3.6.1.4.1.3570.2.2.2.1.2.3.1.1.4SnmpAdminStringread-onlycurrent
paHealth
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3.1.2
paTxOutput
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3.2
paTxOutputForwardPower
OBJECT-TYPE
The measured forward power of the PA output in Watts. Range: 0..100
1.3.6.1.4.1.3570.2.2.2.1.2.3.2.1PowerWread-onlycurrent
paTxOutputVSWR
OBJECT-TYPE
The transmitter's voltage standing wave ratio (VSWR).
1.3.6.1.4.1.3570.2.2.2.1.2.3.2.2Ratioread-onlycurrent
paTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3.4
paGeneral
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.3.5
powerManagementUnit
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.4
pmuSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.4.1
pmuInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.1
pmuInfoProductCode
OBJECT-TYPE
The product code for the PMU.
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.1.1SnmpAdminStringread-onlycurrent
pmuInfoSerialNumber
OBJECT-TYPE
PMU serial number. A unique identifier assigned to the PMU in the factory.
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.1.2SnmpAdminStringread-onlycurrent
pmuInfoHardwareVersion
OBJECT-TYPE
The PMU hardware version number.
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.1.3SnmpAdminStringread-onlycurrent
pmuInfoFirmwareVersion
OBJECT-TYPE
The version number of the firmware currently installed on the PMU.
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.1.4SnmpAdminStringread-onlycurrent
pmuInfoCalibrationUpdateDate
OBJECT-TYPE
Indicates when the PMU was last calibrated.
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.1.5SnmpAdminStringread-onlycurrent
pmuHealth
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.2
pmuSubmodules
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.4.1.3
pmuState
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.4.2
pmuStateMainsInState
OBJECT-TYPE
The condition of the PMU's AC power input. Range: bad(0): The AC power input is off, or too low, or too high. good(1): The AC power input is usable. not fitted(2): The AC power input module is not fitted.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.1Conditionread-onlycurrent
pmuStateBatteryInState
OBJECT-TYPE
The condition of the PMU's DC power input. Range: bad(0): The DC power input is off, or too low, or too high. good(1): The DC power input is usable. not fitted(2): The DC power input module is not fitted.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.2Conditionread-onlycurrent
pmuStateBatteryInVoltage
OBJECT-TYPE
The measured voltage of the DC (battery) power supply to the PMU. Range: 10.5..15.5.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.3VoltageVread-onlycurrent
pmuStateOutCurrent
OBJECT-TYPE
The output current in mA that the PMU is supplying to the subrack (PA(s), reciter(s) and control panel). Range: 0..20000.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.4CurrentmAread-onlycurrent
pmuStateOutVoltage
OBJECT-TYPE
The actual voltage of the PMU output(s) to the PA(s) and reciter(s) in the subrack (nominally 28 V). Range: 0..32.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.5VoltageVread-onlycurrent
pmuStateOutStatus
OBJECT-TYPE
The condition of the PMU power supply to the PA. Range: bad(0): The power supply is absent or its voltage is too low or too high. good(1): The power supply is OK.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.6Conditionread-onlycurrent
pmuStateAuxOutState
OBJECT-TYPE
The condition of the auxiliary power output. Range: bad(0): The auxiliary power is off, or its voltage is too high or too low. good(1): The auxiliary power output is on. not fitted(2): The auxiliary power module is not fitted.
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.7Conditionread-onlycurrent
pmuStateBusConnect
OBJECT-TYPE
The state of the DC supply to the PMU's standby converter. Range: connected(1), not connected(2)
1.3.6.1.4.1.3570.2.2.2.1.2.4.2.9TruthValueread-onlycurrent
frontPanel
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.5
fpSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.5.1
fpInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.5.1.1
fpInfoProductCode
OBJECT-TYPE
The product code for the front panel.
1.3.6.1.4.1.3570.2.2.2.1.2.5.1.1.1SnmpAdminStringread-onlycurrent
fpInfoSerialNumber
OBJECT-TYPE
Front panel serial number. A unique identifier assigned to the front panel in the factory.
1.3.6.1.4.1.3570.2.2.2.1.2.5.1.1.2SnmpAdminStringread-onlycurrent
fpInfoHardwareVersion
OBJECT-TYPE
Front panel hardware version number.
1.3.6.1.4.1.3570.2.2.2.1.2.5.1.1.3SnmpAdminStringread-onlycurrent
fpInfoFirmwareVersion
OBJECT-TYPE
The version number of the firmware currently installed on the front panel.
1.3.6.1.4.1.3570.2.2.2.1.2.5.1.1.4SnmpAdminStringread-onlycurrent
fpHealth
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.2.5.1.2
alarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3
alarmSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.1
alarmSummaryBaseStation
OBJECT-TYPE
Base station summary alarm. The base station currently has one or more active alarms. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.1AlarmStateread-onlycurrent
alarmSummaryReciter
OBJECT-TYPE
Reciter summary alarm. The reciter currently has one or more active alarms. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.2AlarmStateread-onlycurrent
alarmSummaryPowerAmplifier
OBJECT-TYPE
PA summary alarm. The PA currently has one or more active alarms. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.3AlarmStateread-onlycurrent
alarmSummaryPowerManagementUnit
OBJECT-TYPE
PMU summary alarm. The PMU currently has one or more active alarms. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.4AlarmStateread-onlycurrent
alarmSummaryCustomAlarms
OBJECT-TYPE
Custom summary alarm. There are currently one or more active custom alarms. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.5AlarmStateread-onlycurrent
alarmSummaryFrontPanel
OBJECT-TYPE
Front panel summary alarm. The front panel currently has one or more active alarms. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.6AlarmStateread-onlycurrent
alarmSummarySystem
OBJECT-TYPE
System summary alarm. One or more system conditions have triggered alarms. This does not indicate a base station fault. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.7AlarmStateread-onlycurrent
alarmSummaryMinor
OBJECT-TYPE
Minor summary alarm. The base station currently has one or more minor alarms. The node will select other channels in preference. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.8AlarmStateread-onlycurrent
alarmSummaryMajor
OBJECT-TYPE
Major summary alarm. The base station currently has one or more major alarms. The node will take it out of service. Connect to the base station to see what these alarms are. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.1.9AlarmStateread-onlycurrent
reciterAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.3
rctAlarmRxSynthOutOfLock
OBJECT-TYPE
Receiver synthesizer alarm. The receiver synthesizer is unable to lock on to the frequency it is configured to operate at. In response, the base station disabled the receiver. Check that this frequency is within the receiver's RF frequency range. If it is, send the reciter for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.2AlarmStateread-onlycurrent
rctAlarmInvalidChannelSelected
OBJECT-TYPE
Channel invalid alarm. An invalid channel number was selected. The base station has stopped operating. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.3AlarmStateread-onlycurrent
rctAlarmOverTemperature
OBJECT-TYPE
Temperature high alarm. The reciter is approaching its maximum operating temperature. Check if the ambient temperature high alarm is active (Monitor > Alarms > System) and that the reciter, PMU and PA fan Diagnose > Sub-Systems > Fan Tests). This alarm could be caused by a high ambient temperature or a fan failure. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.10AlarmStateread-onlycurrent
rctAlarmTxCalibrationInvalid
OBJECT-TYPE
Transmitter calibration invalid alarm. This alarm activates if the exciter has become uncalibrated. Send the reciter for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.13AlarmStateread-onlycurrent
rctAlarmRxCalibrationInvalid
OBJECT-TYPE
Reciter receiver calibration invalid alarm. The RSSI needs to be calibrated for the operational frequency of the channel. Connect to the base station and re-calibrate the RSSI. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.14AlarmStateread-onlycurrent
rctAlarmInvalidConfiguration
OBJECT-TYPE
Reciter hardware configuration invalid alarm, the base station modules are not compatible Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.15AlarmStateread-onlycurrent
rctAlarm25MHzSynthOutOfLock
OBJECT-TYPE
Synthesizer out of lock alarm. The reciter's 25 MHz synthesizer cannot remain locked to the external reference. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.16AlarmStateread-onlycurrent
rctAlarm6144MHzSynthOutOfLock
OBJECT-TYPE
Synthesizer out of lock alarm. The reciter's 61.44 MHz synthesizer cannot remain locked to the external reference. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.17AlarmStateread-onlycurrent
rctAlarmTxFSynthOutOfLock
OBJECT-TYPE
The TxF synthesizer is unable to lock on to the frequency it is configured to operate at. In response, the base station disabled the transmitter. Send the reciter for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.18AlarmStateread-onlycurrent
rctAlarmSimulcastSynch
OBJECT-TYPE
The base station cannot achieve synchronization to common time reference required for simulcast operation. If simulcast not needed, uncheck simulcast box in channel profile. Otherwise, check 1PPS and External reference units and NTP server and connectors. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.19AlarmStateread-onlycurrent
rctAlarmReceiverSynch
OBJECT-TYPE
Reports whether the receiver is aligned with the transmit TDMA frame synchronization of the transmitters of the channel group. Possible causes for the receiver unsynchronized alarm are: 1. The reciter does not have a valid 1PPS input and is not able to free run 1PPS [ref]. 2. The reciter is not synchronized to a valid NTP server and is not able to free run NTP time. This alarm should be disabled for other system types. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.20AlarmStateread-onlycurrent
rctAlarmTxRSynthOutOfLock
OBJECT-TYPE
The TxR synthesizer is unable to lock on to the frequency it is configured to operate at. In response, the base station disabled the transmitter. Send the reciter for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.3.21AlarmStateread-onlycurrent
paAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.4
paAlarmNoPADetected
OBJECT-TYPE
PA not detected alarm. The reciter has not received a response from a PA over the control bus. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.1AlarmStateread-onlycurrent
paAlarmInvalidFirmware
OBJECT-TYPE
PA firmware invalid alarm. The firmware in the PA is invalid. 1. Connect to the base station and activate the latest PA firmware. 2. Replace the PA and send it for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.2AlarmStateread-onlycurrent
paAlarmInvalidCalibration
OBJECT-TYPE
Invalid PA calibration alarm. This alarm can only be triggered on start-up, when the PA carries out self-tests. It indicates that settings stored in firmware have values outside acceptable limits. In response, the base station disables the transmitter. Contact your regional Tait office for assistance. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.3AlarmStateread-onlycurrent
paAlarmForwardPowerLow
OBJECT-TYPE
Forward power low alarm. The PA forward power output is below the configured minimum limit. If the VSWR is also raised, check for a load mismatch. Otherwise, there may be a fault in the output driver(s). Replace the PA and send for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.5AlarmStateread-onlycurrent
paAlarmPowerFoldback
OBJECT-TYPE
Power foldback alarm. The PA has detected a fault condition and, to prevent damage, reduced its power output to 35 Watts. (But only if the configured power output is higher than 35 Watts. If the configured output is less than or equal to 35, it stays the same.) Check the other alarms to see what fault condition(s) have caused this. If the fault clears, the PA automatically returns to its previous power output level and the alarm returns to green. This alarm causes the node to take the base station out of service. Once the problem is fixed, you need to send a test transmission to clear the alarm. Only then will the node bring the channel back into service. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.7AlarmStateread-onlycurrent
paAlarmReversePowerHigh
OBJECT-TYPE
Reverse power high alarm. The PA's reverse power is above the configured maximum. Check for a load mismatch. This alarm has a resolution of only 1W so it isn't sufficiently sensitive for power outputs below 20W. Note: This alarm will not show if the transmit combiner uses an isolator. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.8AlarmStateread-onlycurrent
paAlarmShutdownImminent
OBJECT-TYPE
PA shut-down alarm. The PA is not operational. It detected a fault condition and disabled the transmitter to prevent damage. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.9AlarmStateread-onlycurrent
paAlarmVSWRFault
OBJECT-TYPE
VSWR alarm. The PA's Voltage Standing Wave Ratio (VSWR) is above the configured threshold. A normal VSWR is <= 2:1. A high VSWR automatically means reduced output power. If the VSWR increases to 10:1 or more, the PA folds back its power output to a low level. If the VSWR returns to 5:1 or less, the PA recovers. Check for a load mismatch on the RF output. This alarm causes the node to take the base station out of service. Once the problem is fixed, you need to send a test transmission to clear the alarm. Only then will the node bring the channel back into service. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.10AlarmStateread-onlycurrent
paAlarmDriverCurrentHigh
OBJECT-TYPE
Driver current high alarm. The driver is drawing excessive current. A fixed limit has been exceeded. Replace the PA and send it for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.11AlarmStateread-onlycurrent
paAlarmFinal1CurrentHigh
OBJECT-TYPE
Final 1 current high alarm. The current in the PA's final 1 output stage has exceeded a fixed limit. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.12AlarmStateread-onlycurrent
paAlarmFinal2CurrentHigh
OBJECT-TYPE
Final 2 current high alarm. The current in the PA's final 2 output stage has exceeded a fixed limit. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.13AlarmStateread-onlycurrent
paAlarmCurrentImbalance
OBJECT-TYPE
Current imbalance alarm. One of the PA's final stages is drawing significantly more current than the other. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.14AlarmStateread-onlycurrent
paAlarmSupplyVoltageLow
OBJECT-TYPE
Supply voltage low alarm. The PA supply voltage is 26 V or less, probably because the battery supply to the PMU is running low. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.15AlarmStateread-onlycurrent
paAlarmSupplyVoltageHigh
OBJECT-TYPE
Supply voltage high alarm. The power supplied to the PA is 29 V or more. The PMU is faulty and needs replacing, Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.16AlarmStateread-onlycurrent
paAlarmDriverTemperatureHigh
OBJECT-TYPE
Driver temperature high alarm. The temperature in the PA's driver output stage has exceeded the configured threshold. If it continues to rise and exceeds a built-in limit, the PA will fold back its power output. To see the actual temperature, connect to the base station and select Diagnose > Sub-Systems > Fan Tests. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.17AlarmStateread-onlycurrent
paAlarmFinal1TemperatureHigh
OBJECT-TYPE
Final 1 temperature high alarm. The temperature in the PA's final 1 output stage has exceeded the configured threshold. If it continues to rise and exceeds a built-in limit, the PA will fold back its power output. To see the actual temperature, connect to the base station and select Diagnose > Sub-Systems > Fan Tests. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.18AlarmStateread-onlycurrent
paAlarmFinal2TemperatureHigh
OBJECT-TYPE
Final 2 temperature high alarm. The temperature in the PA's final 2 output stage has exceeded the configured threshold. If it continues to rise and exceeds a built-in limit, the PA will fold back its power output. To see the actual temperature, connect to the base station and select Diagnose > Sub-Systems > Fan Tests. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.4.19AlarmStateread-onlycurrent
pmuAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.5
pmuAlarmNoPMUDetected
OBJECT-TYPE
PMU not detected alarm. The reciter has not received a response from the PMU over the control bus. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.1AlarmStateread-onlycurrent
pmuAlarmInvalidFirmware
OBJECT-TYPE
PMU firmware invalid alarm. The firmware in the PMU is invalid. 1. Connect to the base station and activate the PMU firmware. 2. Replace the PMU and send it for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.2AlarmStateread-onlycurrent
pmuAlarmMainsFailure
OBJECT-TYPE
Mains supply alarm. The mains power supply to the PMU is absent or its voltage is outside acceptable limits. The PMU is using DC power instead. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.4AlarmStateread-onlycurrent
pmuAlarmSelfTestFailure
OBJECT-TYPE
PMU power-up fault. During start-up, the PMU detected an internal error and will reset itself. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.5AlarmStateread-onlycurrent
pmuAlarmShutdownImminent
OBJECT-TYPE
Shut-down imminent alarm. A battery is currently powering the base station and its voltage has fallen below the configured power shut-down voltage. The PMU will shut down 30 seconds after activating this alarm. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.6AlarmStateread-onlycurrent
pmuAlarmTemperatureHigh
OBJECT-TYPE
PMU temperature alarm. One of the PMU temperature sensors has detected a temperature that is above the fixed limit. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.7AlarmStateread-onlycurrent
pmuAlarmBatteryProtect
OBJECT-TYPE
Battery protection mode alarm. Battery protection mode is on. If mains power fails, the PMU will shut down to protect the battery. Battery protection mode is entered when the battery voltage falls below the configured power shutdown voltage. Check the battery backup system. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.8AlarmStateread-onlycurrent
pmuAlarmBatteryVoltageLow
OBJECT-TYPE
Low battery voltage alarm. The DC voltage supply to the PMU is below the configured alarm threshold. If mains power is lost, the PMU is likely to reduce its output voltage or shut down. Check the charging system. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.9AlarmStateread-onlycurrent
pmuAlarmBatteryVoltageHigh
OBJECT-TYPE
Battery voltage high alarm. The voltage of the DC power supply to the PMU is higher than the configured maximum. The base station takes no action until the voltage reaches the fixed maximum, when it shuts down. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.10AlarmStateread-onlycurrent
pmuAlarmCurrentOutHigh
OBJECT-TYPE
PMU high current alarm. The PMU is providing > 15 A of current and is automatically lowering its output voltage. There is a short circuit or the PMU is faulty. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.11AlarmStateread-onlycurrent
pmuAlarmVoltageOutLow
OBJECT-TYPE
Output voltage low alarm. The PMU's DC output (nominally 28 V) is lower than the fixed minimum of 24 V. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.12AlarmStateread-onlycurrent
pmuAlarmVoltageOutHigh
OBJECT-TYPE
High voltage alarm. The PMU's DC output (nominally 28 V) is higher than the fixed maximum of 32 V. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.5.13AlarmStateread-onlycurrent
customAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.6
customAlarm1
OBJECT-TYPE
Custom alarm 1. The state of digital input 1 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.1AlarmStateread-onlycurrent
customAlarm2
OBJECT-TYPE
Custom alarm 2. The state of digital input 2 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.2AlarmStateread-onlycurrent
customAlarm3
OBJECT-TYPE
Custom alarm 3. The state of digital input 3 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.3AlarmStateread-onlycurrent
customAlarm4
OBJECT-TYPE
Custom alarm 4. The state of digital input 4 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.4AlarmStateread-onlycurrent
customAlarm5
OBJECT-TYPE
Custom alarm 5. The state of digital input 5 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.5AlarmStateread-onlycurrent
customAlarm6
OBJECT-TYPE
Custom alarm 6. The state of digital input 6 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.6AlarmStateread-onlycurrent
customAlarm7
OBJECT-TYPE
Custom alarm 7. The state of digital input 7 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.7AlarmStateread-onlycurrent
customAlarm8
OBJECT-TYPE
Custom alarm 8. The state of digital input 8 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.8AlarmStateread-onlycurrent
customAlarm9
OBJECT-TYPE
Custom alarm 9. The state of digital input 9 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.9AlarmStateread-onlycurrent
customAlarm10
OBJECT-TYPE
Custom alarm 10. The state of digital input 10 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.10AlarmStateread-onlycurrent
customAlarm11
OBJECT-TYPE
Custom alarm 11. The state of digital input 11 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.11AlarmStateread-onlycurrent
customAlarm12
OBJECT-TYPE
Custom alarm 12. The state of digital input 12 has changed, triggering this alarm. This occurs when external equipment has been connected to the input. When configured as 'active high', a custom alarm is triggered when its input goes to 'high' (4.75V) and it is cleared when its input goes to 'low'. When configured as 'active low', a custom alarm is triggered when its input goes to 'low' (0V) and it is cleared when its input goes to 'high'. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.6.12AlarmStateread-onlycurrent
fpAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.7
fpAlarmFan1
OBJECT-TYPE
Fan alarm. The reciter has failed to detect Fan 1 when attempting to activate it upon start-up or when a module temperature threshold is exceeded. The fan may need replacing. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.7.1AlarmStateread-onlycurrent
fpAlarmFan2
OBJECT-TYPE
Fan alarm. The reciter has failed to detect Fan 2 when attempting to activate it upon start-up or when a module temperature threshold is exceeded. The fan may need replacing. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.7.2AlarmStateread-onlycurrent
fpAlarmFan3
OBJECT-TYPE
Fan alarm. The reciter has failed to detect Fan 3 when attempting to activate it upon start-up or when a module temperature threshold is exceeded. The fan may need replacing. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.7.3AlarmStateread-onlycurrent
fpAlarmNoFPDetected
OBJECT-TYPE
The base station is unable to detect the front panel on the control bus. Check the connections of the D-range connector and system control bus cable. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.7.4AlarmStateread-onlycurrent
fpAlarmInvalidFirmware
OBJECT-TYPE
Invalid front panel firmware alarm. Connect to the base station and select Tools > Firmware Download to acquire valid firmware. If the firmware is valid contact your regional Tait office for assistance. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.7.5AlarmStateread-onlycurrent
systemAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.3.8
systemAlarmAmbientTempLow
OBJECT-TYPE
Ambient temperature low alarm. The ambient temperature at the front panel air intake is below the configured minimum. Fan operation and PA power output are unaffected by this alarm. This alarm could indicate an air conditioning failure. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.1AlarmStateread-onlycurrent
systemAlarmAmbientTempHigh
OBJECT-TYPE
Ambient temperature high alarm. The ambient temperature at the front panel air intake has exceeded the configured maximum. Fan operation and PA power output are unaffected by this alarm. This alarm could indicate an air conditioning failure.
1.3.6.1.4.1.3570.2.2.2.1.3.8.2AlarmStateread-onlycurrent
systemAlarmExternalRefAbsent
OBJECT-TYPE
External frequency reference absent alarm. The base station did not detect an external reference frequency source. It is now using its own source. An external reference is critical for simulcast applications and for K-band operation. 1. The source has become unplugged. 2. The source is not working. 3. There is no external reference source and the alarm was not disabled at installation time. You can disable the alarm (Configure > Alarms > Control). Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.3AlarmStateread-onlycurrent
systemAlarmQoSJitter
OBJECT-TYPE
QoS jitter alarm. The incoming voice stream has a jitter equal to or greater than the configured threshold. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.4AlarmStateread-onlycurrent
systemAlarmQoSLostPackets
OBJECT-TYPE
QoS lost packets alarm. The number of lost packets in the incoming voice stream has equalled or exceeded the configured threshold. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.5AlarmStateread-onlycurrent
systemAlarmFallbackControlled
OBJECT-TYPE
This base station is controlled by an Embedded Node in fallback mode.
1.3.6.1.4.1.3570.2.2.2.1.3.8.6AlarmStateread-onlycurrent
systemAlarmDuplicateNodePriority
OBJECT-TYPE
The base station's BSP priority is being used by another base station on the same site. This alarm is raised only if the base station has been configured as 'CCH Capable'.
1.3.6.1.4.1.3570.2.2.2.1.3.8.7AlarmStateread-onlycurrent
systemAlarmNTPSynchronisation
OBJECT-TYPE
The base station hasn't had received an NTP signal from a server and the clock might be out of synchronization. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.8AlarmStateread-onlycurrent
systemAlarm1PPSAbsent
OBJECT-TYPE
In a simulcast system base stations must have a 1PPS pulse. This alarm should be disabled for other systems. It is not applicable to receive only base stations. The alarm warns that the base station isn't receiving a 1PPS pulse. If the base station loses the pulse but is still receiving its external reference, it phase-locks its transmit clock to the external frequency reference in order to maintain synchronization. This is called Holdover mode and is a temporary measure. When the holdover duration expires the base station becomes unsynchronized. The 'Simulcast unsynchronized' alarm under 'Reciter' below indicates whether the base station is synchronized for simulcast operation. The 'Receiver unsynchronised' alarm in this section indicates whether the base station receiver is synchronized. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.9AlarmStateread-onlycurrent
systemAlarmQoSTransmitBuffer
OBJECT-TYPE
Simulcast satellite base station is receiving packets that cannot fit into the transmit buffer. The alarm can be raised due to one of the two reasons: packets arriving too late or too early. See nwQosUnderflowCount and nwQosOverflowCount for the events that cause the alarm condition. Most likely causes for packets being late are jitter, delay and configuration errors. Most likely cause for packets being too early is preemption. Use SNMP monitoring tools and base station's WUI (Monitoring->Interfaces->Channel Group) to identify the cause. Refer to logs, if the event has happened too far in the past. The alarm is asserted when rate of non-transmitted packets exceeds 1 percent. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.10AlarmStateread-onlycurrent
systemAlarmCartesianLoopUnstable
OBJECT-TYPE
PA feedback loop to linearise transmitter can't achieve specified tolerances. Check TxR cable connected properly, otherwise return for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.11AlarmStateread-onlycurrent
systemAlarmTxRCableAbsent
OBJECT-TYPE
PA feedback cable to reciter TxR is not working correctly/not present. Ensure that the TxR cable between PA and Reciter TxR is unbroken and connected securely, or return for repair. Range: unavailable(0), cleared(1), raised(2), disabled(3)
1.3.6.1.4.1.3570.2.2.2.1.3.8.12AlarmStateread-onlycurrent
networkLinksSummary
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.4.1
linkInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.4.1.1
linkInfoCtrlProtocolStatus
OBJECT-TYPE
The status of the base station as reported to the node using the control protocol. Range: unconnected(0): The base station is not under node control. deprecatedUnconnected(1): DEPRECATED - The base station is not in contact with a node. standby(2): The base station is in contact with a node. Its air interface is not transmitting or receiving. dmr-aligned(3): The base station is transmitting a framesync structure together with an idle pattern or a payload. dmr-offset(4): Not currently used. dmr-two-slot-data(5): The base station is carrying a data call that uses both logical channels. dmr-hibernate(6): the base station is hibernating analogue(7): Not currently used. test-mode(8): Reserved. dmr-tier2-aligned(9): The base station is transmitting a framesync struture for Tier 2 operation
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.1ControlProtocolStatusread-onlycurrent
linkInfoNetworkPacketCount
OBJECT-TYPE
Total packets received from the network on control and data protocols. This is an accumulating number. The counter is large enough that the number rolls over infrequently, such as once every few months, depending on call volumes.
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.2Counter32read-onlycurrent
linkInfoMPTCtrlProtocolStatus
OBJECT-TYPE
The status of the base station as reported to the node using the control protocol. unconnected(0): The base-station is not connected to any MPT-IP node, neither external nor fallback. idle(1): The base-station is connected to a MPT-IP node (either external or fallback). It is not transmitting anything on its air interface (transmitter is off). control(2): The base-station is connected to a MPT-IP node (either external or fallback). Air interface transmitting and receiving MPT control channel signalling only. traffic(3): The base-station is connected to a MPT-IP node (either external or fallback). Voice/Data packets are sent to and received from node, Air interface is transmitting as well as receiving. conventional(4): The base-station is connected to a fallback node. Voice/Data packets are repeated locally from uplink to downlink. Air interface is transmitting as well as receiving.
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.3MPTControlProtocolStatusread-onlycurrent
linkInfoDMRNodeIPAddress
OBJECT-TYPE
The IP address of the DMR Node Controlling the base station.
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.4SnmpAdminStringread-onlycurrent
linkInfoDMRNodePriority
OBJECT-TYPE
The priority of the DMR Node Controlling the base station.
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.5Unsigned32read-onlycurrent
linkInfoMPTNodeIPAddress
OBJECT-TYPE
The IP address of the MPT Node Controlling the base station.
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.6SnmpAdminStringread-onlycurrent
linkInfoMPTNodePriority
OBJECT-TYPE
The priority of the MPT Node Controlling the base station.
1.3.6.1.4.1.3570.2.2.2.1.4.1.1.7Unsigned32read-onlycurrent
linkHealth
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.4.1.2
linkHealthNetworkPacketLostCount
OBJECT-TYPE
Total accumulated number of lost voice and control packets sent from the control and switching nodes. An increasing number indicates that the linking infrastructure has a problem or is congested.
1.3.6.1.4.1.3570.2.2.2.1.4.1.2.2Counter32read-onlycurrent
linkHealthNetworkJitterLastOver
OBJECT-TYPE
The maximum jitter measured in the last over.
1.3.6.1.4.1.3570.2.2.2.1.4.1.2.3Unsigned32read-onlycurrent
linkHealthNetworkJitterCount
OBJECT-TYPE
The total number of times the configured jitter threshold has been exceeded.
1.3.6.1.4.1.3570.2.2.2.1.4.1.2.4Counter32read-onlycurrent
linkHealthSequenceErrorsCount
OBJECT-TYPE
The result of lost packets - i.e. the number of times packets have been received out of sequence. This is an accumulating number.
1.3.6.1.4.1.3570.2.2.2.1.4.1.2.5Counter32read-onlycurrent
networkInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.5
nwNtpInterface
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.5.1
nwConfiguredNtpServerAddress
OBJECT-TYPE
The IP address configured for the preferred NTP server used by the base-station. The current status of NTP for the base-station including the selected server is available via the NTPv4-MIB (RFC 5907)
1.3.6.1.4.1.3570.2.2.2.1.5.1.1DisplayStringread-onlycurrent
nwConfiguredNtpBackupServerAddress1
OBJECT-TYPE
The IP address configured for a backup NTP server used by the base-station. The current status of NTP for the base-station including the backup servers is available via the NTPv4-MIB (RFC 5907)
1.3.6.1.4.1.3570.2.2.2.1.5.1.2DisplayStringread-onlycurrent
nwConfiguredNtpBackupServerAddress2
OBJECT-TYPE
The IP address configured for a backup NTP server used by the base-station. The current status of NTP for the base-station including the backup servers is available via the NTPv4-MIB (RFC 5907)
1.3.6.1.4.1.3570.2.2.2.1.5.1.3DisplayStringread-onlycurrent
nwChannelGroup
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.5.2
nwChannelGroupStatus
OBJECT-TYPE
The voting role that the base station is currently playing within the channel group.
1.3.6.1.4.1.3570.2.2.2.1.5.2.1ChannelGroupStatusread-onlycurrent
nwChannelGroupLocalBufferLevel
OBJECT-TYPE
The lowest level of the transmit buffer, measured in milliseconds over a 5-second period.
1.3.6.1.4.1.3570.2.2.2.1.5.2.2Millisecondsread-onlycurrent
nwChannelGroupEmptiestBufferLevel
OBJECT-TYPE
The level of the transmit buffer (in ms) at the member that has got emptiest buffer-level. It is the smallest transmit buffer of any channel group member. If marshalling is self-regulating, the central voter is responsible for ensuring that there are no buffer underruns. If marshalling is fixed, the marshalling duration must be long enough to prevent buffer underruns.
1.3.6.1.4.1.3570.2.2.2.1.5.2.3Millisecondsread-onlycurrent
nwChannelGroupMarshallingType
OBJECT-TYPE
[Simulcast] The Marshalling Type configuration setting indicates how the marshalling time is determined. Range: fixed(0): Configuration defines the marshalling time. self-regulating(1): The network element dynamically adjusts the marshalling time based on the size of the smallest transmit buffer in the channel group.
1.3.6.1.4.1.3570.2.2.2.1.5.2.4TimingControlTyperead-onlycurrent
nwChannelGroupMarshallingDuration
OBJECT-TYPE
In simulcast, the current marshalling duration (in ms). This is fixed in configuration or automatically regulated. This parameter is only used by the central voter (channel group master). Range: 0..300
1.3.6.1.4.1.3570.2.2.2.1.5.2.5Millisecondsread-onlycurrent
nwChannelGroupReceiverSynchStatus
OBJECT-TYPE
The receiver synchronization status indicates whether the base station's receiver is synchronized and if not then gives reasons why. Range: no-license(0): The base station does not have a license to operate in Simulcast mode. non-channelgroup-operation(1):The current channel group profile does not enable channel group operation. synchronized(2): The transmitter is able to synchronize its transmissions with the other members of the channel group. Simulcast is functioning properly. never-had-1pps(3): The base station has never had a 1PPS signal. It is either faulty or absent and is therefore unsynchronized. never-had-ntp(4): The base station has never had NTP so it is therefore unsynchronized. missing-1pps-or-ntp(5): 1PPS or NTP is faulty or absent after initial synchronisation.
1.3.6.1.4.1.3570.2.2.2.1.5.2.6ReceiverSyncStatusread-onlycurrent
nwChannelGroupTransmitterSynchStatus
OBJECT-TYPE
The Synchronization status indicates whether the base station's transmission is synchronized and if not then gives reasons why. A base station transmitter in a simulcast channel group must be synchronized for simulcast operation. An unsynchronized base station does not transmit, unless it is specifically configured to transmit even though unsynchronized. Range: no-license(0): The base station does not have a license to operate in Simulcast mode. non-simulcast-operation(1): The current channel profile does not enable simulcast. bad-frequency-reference(2): The base station has frequency reference either faulty or absent and is therefore unsynchronized. never-had-1pps(3): The base station has never had a 1PPS. It is either faulty or absent and is therefore unsynchronized. never-had-ntp(4): The base station has never had NTP so it is therefore unsynchronized. missing-1pps-or-ntp(5): 1PPS or NTP is faulty or absent after initial synchronisation. synchronized(6): The transmitter is able to synchronize its transmissions with the other members of the channel group. Simulcast is functioning properly. non-channelgroup-operation(7):The current channel profile does not enable channel group operation.
1.3.6.1.4.1.3570.2.2.2.1.5.2.7TransmitterSyncStatusread-onlycurrent
nwChannelGroupLateStreamsCount
OBJECT-TYPE
The number of times any transmission stream arrives later than the required transmit time. The count is aggregated one since system-startup.
1.3.6.1.4.1.3570.2.2.2.1.5.2.8Counter32read-onlycurrent
nwChannelGroupOverflowCount
OBJECT-TYPE
The number of channelgroup messages that did not fit in the transmit buffer or were too far into the future. The count is total such messages since system-startup.
1.3.6.1.4.1.3570.2.2.2.1.5.2.9Counter32read-onlycurrent
nwChannelGroupUnderflowCount
OBJECT-TYPE
The number of times transmit-buffer ran empty, since system-startup.
1.3.6.1.4.1.3570.2.2.2.1.5.2.10Counter32read-onlycurrent
nwChannelGroupLostPacketsCount
OBJECT-TYPE
The number of packets that were lost during a transmission stream, based on the packet sequence numbering. The count is aggregated one since system-startup.
1.3.6.1.4.1.3570.2.2.2.1.5.2.11Counter32read-onlycurrent
nwChannelGroupJitter
OBJECT-TYPE
The jitter-value calculated in compliance with RFC-1889. It is the mean deviation (absolute value) of the difference in packet spacing at the receiver compared to the sender for a pair of packets. The value is in milliseconds.
1.3.6.1.4.1.3570.2.2.2.1.5.2.12INTEGERread-onlycurrent
nwPorts
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.1.5.3
nwSvpPort
OBJECT-TYPE
The configured Simulcast Voted protocol UDP port.
1.3.6.1.4.1.3570.2.2.2.1.5.3.1Unsigned32read-onlycurrent
mibConformance
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.5
mibGroups
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.5.1
mibCompliance
OBJECT-IDENTITY
1.3.6.1.4.1.3570.2.2.2.5.2

Conformance

NameOIDStatus
healthGroup
OBJECT-GROUP
The health Group.
1.3.6.1.4.1.3570.2.2.2.5.1.1current
alarmSummaryGroup
OBJECT-GROUP
The alarmSummary Group.
1.3.6.1.4.1.3570.2.2.2.5.1.2current
rctSelectedChannelGroup
OBJECT-GROUP
The rctSelectedChannel Group.
1.3.6.1.4.1.3570.2.2.2.5.1.3current
paTxOutputGroup
OBJECT-GROUP
The paTxOutput Group.
1.3.6.1.4.1.3570.2.2.2.5.1.5current
linkInfoGroup
OBJECT-GROUP
The linkInfo Group.
1.3.6.1.4.1.3570.2.2.2.5.1.6current
customAlarmsGroup
OBJECT-GROUP
The customAlarms group.
1.3.6.1.4.1.3570.2.2.2.5.1.7current
systemAlarmsGroup
OBJECT-GROUP
The systemAlarms Group.
1.3.6.1.4.1.3570.2.2.2.5.1.8current
fpAlarmsGroup
OBJECT-GROUP
The fpAlarms Group.
1.3.6.1.4.1.3570.2.2.2.5.1.9current
paAlarmsGroup
OBJECT-GROUP
The paAlarms Group.
1.3.6.1.4.1.3570.2.2.2.5.1.10current
pmuAlarmsGroup
OBJECT-GROUP
The pmuAlarms Group.
1.3.6.1.4.1.3570.2.2.2.5.1.11current
reciterAlarmsGroup
OBJECT-GROUP
The reciterAlarms Group.
1.3.6.1.4.1.3570.2.2.2.5.1.12current
infoGroup
OBJECT-GROUP
The info Group.
1.3.6.1.4.1.3570.2.2.2.5.1.13current
rctReceiveQualityGroup
OBJECT-GROUP
The receive quality Group.
1.3.6.1.4.1.3570.2.2.2.5.1.14current
rctReceiverGroup
OBJECT-GROUP
The receiver Group.
1.3.6.1.4.1.3570.2.2.2.5.1.15current
rctTemperatureGroup
OBJECT-GROUP
The reciter temperature group.
1.3.6.1.4.1.3570.2.2.2.5.1.16current
pmuStateGroup
OBJECT-GROUP
The pmu status indications group.
1.3.6.1.4.1.3570.2.2.2.5.1.17current
nwNtpInterfaceGroup
OBJECT-GROUP
The network ntp interface group.
1.3.6.1.4.1.3570.2.2.2.5.1.18current
rctTransmitterGroup
OBJECT-GROUP
The transmitter group.
1.3.6.1.4.1.3570.2.2.2.5.1.19current
nwChannelGroupGroup
OBJECT-GROUP
The group for channelgroup.
1.3.6.1.4.1.3570.2.2.2.5.1.20current
nwPortsGroup
OBJECT-GROUP
Network ports
1.3.6.1.4.1.3570.2.2.2.5.1.21current
rctSystemInterfaceGroup
OBJECT-GROUP
Reciter system interface
1.3.6.1.4.1.3570.2.2.2.5.1.22current
linearTransmissionCapability
OBJECT-GROUP
Information depending on existence of a linear power amplifier
1.3.6.1.4.1.3570.2.2.2.5.1.23current
pmuInfoGroup
OBJECT-GROUP
The PMU info group.
1.3.6.1.4.1.3570.2.2.2.5.1.24current
deprecatedOidGroup
OBJECT-GROUP
Deprecated OIDs
1.3.6.1.4.1.3570.2.2.2.5.1.27deprecated
mibComplianceList
MODULE-COMPLIANCE
The requirements for conformance to the TAIT-INFRA93SERIES-MIB.
1.3.6.1.4.1.3570.2.2.2.5.2.1current