SYNSO-UPSMIB

Registered at
1.3.6.1.4.1.9557
Namespace
synso
Source file
SYNSO-UPSMIB
Digest
sha256:44b822415dc74cf3ff277dd37d7c1c9822002574de19c984a3c06b8a8bfeff96

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIIpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
SYNSO-UPSMIB

Objects

NameOIDSyntaxAccessStatus
synso
OBJECT-IDENTITY
1.3.6.1.4.1.9557
synsoUpsSoftware
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1
syupsBasicSetting
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.1
syupsPlatForm
OBJECT-TYPE
The platform which the UPS software is running on.
1.3.6.1.4.1.9557.1.1.1DisplayString (SIZE(0..31))read-onlymandatory
syupsFeatureTable
OBJECT-TYPE
A table containing the supported features.
1.3.6.1.4.1.9557.1.1.2not-accessiblemandatory
syupsFeatureEntry
OBJECT-TYPE
An entry representing the support information for a feature.
1.3.6.1.4.1.9557.1.1.2.1not-accessiblemandatory
syupsFeature
OBJECT-TYPE
The string representing a feature.
1.3.6.1.4.1.9557.1.1.2.1.1INTEGERread-onlymandatory
syupsSupportInfo
OBJECT-TYPE
The string containing the support information for a feature.
1.3.6.1.4.1.9557.1.1.2.1.2DisplayStringread-onlymandatory
syupsSystemStartTime
OBJECT-TYPE
The time that the UPS software starts. It is the number of seconds elapsed since 00:00:00, January 1, 1970.
1.3.6.1.4.1.9557.1.1.3INTEGERread-onlymandatory
syupsSignalType
OBJECT-TYPE
The signaling method between the UPS and software. When the basicSignal used, the UPS changes the voltage level of some specific pins to notify the software of what critical event occurs. Usually, the UPS will inform software when a power failure or a low battery condition occurs. On the other hand, the software can change the voltage signal of a specific pin to ask the UPS to shut down (turn off). When the smartSignal used, the UPS asks like a standard communication device (such as mouse or modem). That means the UPS and software communicate with each other using a pre-defined protocol. The protocol should include at least the following commands: - query the power status of the UPS - query the power data of the UPS - command the UPS to shut down
1.3.6.1.4.1.9557.1.1.4INTEGER {basicSignal(0), smartSignal(1)}read-writemandatory
syupsBasicSignalDefinition
OBJECT-TYPE
The signal definitions for the basic signaling UPS. The value can be the following bit combinations: SG_POWER_FAILURE_ENABLE 0x01 SG_BATTERY_LOW_ENABLE 0x02 SG_SHUTDOWN_ENABLE 0x04 SG_POWER_FAILURE_VOLTHIGH 0x10 SG_BATTERY_LOW_VOLTHIGH 0x20 SG_SHUTDOWN_VOLTHIGH 0x40 SG_POWER_FAILURE_ENABLE, SG_BATTERY_LOW_ENABLE, and SG_SHUTDOWN_ENABLE indicate whether the signals for a power failure , a low battery condition, and the UPS shutdown are enabled. SG_POWER_FAILURE_VOLTHIGH, SG_BATTERY_LOW_VOLTHIGH, and SG_SHUTDOWN_VOLTHIGH indicate whether the voltage level for these signals are high or low.
1.3.6.1.4.1.9557.1.1.5INTEGERread-onlymandatory
syupsUpsComPort
OBJECT-TYPE
The serial port which the UPS software use to communicate with the UPS. The format varies from platform to platform. For DOS program, the format is 'portNo, portAddress, portIRQ' (e.g. '1, 0x2f8, 3' for COM2). For Windows program, it is 'portNo'. For NetWare program, it is 'portType, boardNo, portNo'. For UNIX, it is 'device name'.
1.3.6.1.4.1.9557.1.1.6DisplayString (SIZE(0..31))read-writemandatory
syupsModemComPort
OBJECT-TYPE
The serial port which the UPS software use to dial out when some particular events occur. The format varies from platform to platform. For DOS program, the format is 'portNo, portAddress, portIRQ' (e.g. '1, 0x2f8, 3' for COM2). For Windows program, it is 'portNo'. For NetWare program, it is 'portType, boardNo, portNo'. For UNIX, it is 'device name'.
1.3.6.1.4.1.9557.1.1.7DisplayString (SIZE(0..31))read-writemandatory
syupsUpsExtension
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.2
syupsUpsAlarm
OBJECT-TYPE
It is used internally. Each bit indicates a critical event, such as input bad, on battery, communications lost, ...,etc.
1.3.6.1.4.1.9557.1.2.1INTEGERread-onlymandatory
syupsSerialNo
OBJECT-TYPE
The serial number of the UPS connected to the UPS software.
1.3.6.1.4.1.9557.1.2.2DisplayString (SIZE(0..63))read-onlymandatory
syupsConfigBatteryVoltage
OBJECT-TYPE
The nominal battery voltage.
1.3.6.1.4.1.9557.1.2.3INTEGERread-onlymandatory
syupsBatteryReplaceDate
OBJECT-TYPE
The last battery replacement date. It represents the number of days elapsed since January 1, 1901.
1.3.6.1.4.1.9557.1.2.4INTEGERread-writemandatory
syupsNoOutlet
OBJECT-TYPE
The total number of controllable outlets.
1.3.6.1.4.1.9557.1.2.5INTEGERread-onlymandatory
syupsOutletParamter
OBJECT-TYPE
This object is not used any more.
1.3.6.1.4.1.9557.1.2.6DisplayStringread-writemandatory
syupsShutdownDepend
OBJECT-TYPE
A string containing those who should perform their shutdown procedure before the UPS turns off. The agent will inform each one in the list to begin their shutdown procedure before it turns off the power of the UPS.
1.3.6.1.4.1.9557.1.2.7DisplayString (SIZE(0..255))read-writemandatory
syupsEnableAutoSave
OBJECT-TYPE
Setting it to 1, the agent will try to save all files opened by applications before shutting down the operation system. Setting it to 0 will disable the auto save feature.
1.3.6.1.4.1.9557.1.2.8INTEGERread-writemandatory
syupsShutdownOsDelay
OBJECT-TYPE
The delay time before shutting down the operation system. When it is necessary to shut down the operation system, the agent will run the specified command file and try to save all files opened by applications before shutting down the OS. This delay time is used to do such things.
1.3.6.1.4.1.9557.1.2.9INTEGERread-writemandatory
syupsShutdownUpsDelay
OBJECT-TYPE
The delay time before shutting down the UPS. Before shutting down the operation system, the agent will send a command to tell the UPS to shut down. This delay time is used to allow the agent to shut down the operation system safely.
1.3.6.1.4.1.9557.1.2.10INTEGERread-writemandatory
syupsSaveConfig
OBJECT-TYPE
Used to inform the agnet to save the configurations. Its value indicates which group to be saved. For example, a 1 indicates group 1 (syupsBasicSetting) to be saved, a 6 1 indicates group 6 (syupsCoworker) to be saved. You have to use it to save configurations after changing settings, or the settings may be lost.
1.3.6.1.4.1.9557.1.2.11INTEGERread-writemandatory
syupsNoOutlets
OBJECT-TYPE
The number of controllable outlets.
1.3.6.1.4.1.9557.1.2.12INTEGERread-onlymandatory
syupsOutletTable
OBJECT-TYPE
A list of outlet table entries. The number of entries is given by the value of syupsNoOutlets.
1.3.6.1.4.1.9557.1.2.13not-accessiblemandatory
syupsOutletEntry
OBJECT-TYPE
An entry containing information applicable to a particular controllable outlet.
1.3.6.1.4.1.9557.1.2.13.1not-accessiblemandatory
syupsOutletIndex
OBJECT-TYPE
The outlet identifier.
1.3.6.1.4.1.9557.1.2.13.1.1INTEGERnot-accessiblemandatory
syupsOutletDescription
OBJECT-TYPE
The outlet description.
1.3.6.1.4.1.9557.1.2.13.1.2DisplayString (SIZE(0..15))read-writemandatory
syupsOutletShutdownDelay
OBJECT-TYPE
The delay time (in seconds) before turning off the outlet. Before turning off the outlet, the agent will send a shutdown command to anyone specified in the syupsOutletShutdownDepend, telling them to start their shutdown procedure. This delay time is used to allow those cmputers to be shut down safely.
1.3.6.1.4.1.9557.1.2.13.1.3INTEGERread-writemandatory
syupsOutletShutdownDepend
OBJECT-TYPE
A string containing those who should perform their shutdown procedure before the outlet turns off. The agent will inform each one in the list to begin their shutdown procedure before it turns off the power of the outlet.
1.3.6.1.4.1.9557.1.2.13.1.4DisplayString (SIZE(0..63))read-writemandatory
syupsOutletOperator
OBJECT-TYPE
The operator is used to control the outlets. There are two commands: 1. 'SWITCH: OutletNo, OnOff'. The OutletNo specify the outlet. The OnOff can be 0 (off) or 1 (on). For example, 'SWITCH: 2, 1' means turning on (1) the outlet #2. 'SWITCH: 4, 0' means turning off (0) the outlet #4. 2. 'SET: OutletNo, Desc, DelayTime, Depend'. The OutletNo specify the outlet. The Desc specifies the outlet description. The DelayTime specifies the shutdown delay time for the outlet. The Depend specifies the shutdown dependent list for the outlet. For example, 'SET: 3, My Printer, 20, 192.168.1.9' means setting the description of outlet #3 to 'My Printer', the shutdown delay time to 20 seconds and the Shutdown Dependent to '192.168.1.9'.
1.3.6.1.4.1.9557.1.2.14DisplayStringread-writemandatory
syupsEventAction
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.3
syupsNoEventActionEntries
OBJECT-TYPE
The number of event-action items. This variable indicates the number of rows in the event-action table.
1.3.6.1.4.1.9557.1.3.1INTEGERread-onlymandatory
syupsEventActionTable
OBJECT-TYPE
A list of event action entries. The number of entries is given by the value of syupsNoEventActionEntries.
1.3.6.1.4.1.9557.1.3.2not-accessiblemandatory
syupsEventActionEntry
OBJECT-TYPE
An entry containing information applicable to a particular event action.
1.3.6.1.4.1.9557.1.3.2.1not-accessiblemandatory
syupsEventId
OBJECT-TYPE
The event ID.
1.3.6.1.4.1.9557.1.3.2.1.1INTEGERread-onlymandatory
syupsLogEnable
OBJECT-TYPE
Whether to log the event in the log file when it occurs. A 1 indicates enable, a 0 indicates disable.
1.3.6.1.4.1.9557.1.3.2.1.2INTEGER {disable(0), enable(1)}read-writemandatory
syupsNotifyEnable
OBJECT-TYPE
Whether to notify users when the event occurs. A 1 indicates enable, a 0 indicates disable.
1.3.6.1.4.1.9557.1.3.2.1.3INTEGER {disable(0), enable(1)}read-writemandatory
syupsNotifyDelay
OBJECT-TYPE
How long the event must last before notifying users.
1.3.6.1.4.1.9557.1.3.2.1.4INTEGERread-writemandatory
syupsNotifyMessage
OBJECT-TYPE
The message which will be sent when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.5DisplayString (SIZE(0..63))read-writemandatory
syupsNotifyPeriod
OBJECT-TYPE
How often (in seconds) to send the message. The -1 means once.
1.3.6.1.4.1.9557.1.3.2.1.6INTEGERread-writemandatory
syupsNotifyUsers
OBJECT-TYPE
Who will receive the message when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.7DisplayString (SIZE(0..255))read-writemandatory
syupsEmailEnable
OBJECT-TYPE
Whether to email users when the event occurs. A 1 indicates enable, a 0 indicates disable.
1.3.6.1.4.1.9557.1.3.2.1.8INTEGER {disable(0), enable(1)}read-writemandatory
syupsEmailDelay
OBJECT-TYPE
How long the event must last before emailing users.
1.3.6.1.4.1.9557.1.3.2.1.9INTEGERread-writemandatory
syupsEmailMessage
OBJECT-TYPE
The additional message which will be sent when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.10DisplayString (SIZE(0..63))read-writemandatory
syupsEmailUsers
OBJECT-TYPE
Who will receive the mail when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.11DisplayString (SIZE(0..255))read-writemandatory
syupsPageEnable
OBJECT-TYPE
Whether to page users when the event occurs. A 1 indicates enable, a 0 indicates disable.
1.3.6.1.4.1.9557.1.3.2.1.12INTEGER {disable(0), enable(1)}read-writemandatory
syupsPageDelay
OBJECT-TYPE
How long the event must last before paging users.
1.3.6.1.4.1.9557.1.3.2.1.13INTEGERread-writemandatory
syupsPageMessage
OBJECT-TYPE
The message which will be sent when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.14DisplayString (SIZE(0..15))read-writemandatory
syupsPageUsers
OBJECT-TYPE
Who will receive the code when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.15DisplayString (SIZE(0..255))read-writemandatory
syupsCommandEnable
OBJECT-TYPE
Whether to execute the external command file when the event occurs. A 1 indicates enable, a 0 indicates disable.
1.3.6.1.4.1.9557.1.3.2.1.16INTEGER {disable(0), enable(1)}read-writemandatory
syupsCommandDelay
OBJECT-TYPE
How long the event must last before executing the external command file.
1.3.6.1.4.1.9557.1.3.2.1.17INTEGERread-writemandatory
syupsCommandFile
OBJECT-TYPE
The external command file which will be executed when the event occurs.
1.3.6.1.4.1.9557.1.3.2.1.18DisplayString (SIZE(0..63))read-writemandatory
syupsShutdownEnable
OBJECT-TYPE
Whether to shut down the system when the event occurs. A 1 indicates enable, a 0 indicates disable.
1.3.6.1.4.1.9557.1.3.2.1.19INTEGER {disable(0), enable(1)}read-writemandatory
syupsShutdownDelay
OBJECT-TYPE
How long the event must last before shutting down the system.
1.3.6.1.4.1.9557.1.3.2.1.20INTEGERread-writemandatory
syupsHistory
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.4
syupsMaxEventFileLength
OBJECT-TYPE
The maximum length (in bytes) of the event log file. UPS software will cut the first half of the file whenever the file exceeds this maximum length.
1.3.6.1.4.1.9557.1.4.1INTEGERread-writemandatory
syupsEventNumRecords
OBJECT-TYPE
The total number of records in the event log file.
1.3.6.1.4.1.9557.1.4.2INTEGERread-onlymandatory
syupsEventTable
OBJECT-TYPE
A list of event entries. Each entry represents a record in the event log file.
1.3.6.1.4.1.9557.1.4.3not-accessiblemandatory
syupsEventEntry
OBJECT-TYPE
An entry representing a record in the event log file.
1.3.6.1.4.1.9557.1.4.3.1not-accessiblemandatory
syupsEventIndex
OBJECT-TYPE
The record number of an event entry.
1.3.6.1.4.1.9557.1.4.3.1.1INTEGERread-onlymandatory
syupsEventRecord
OBJECT-TYPE
The string containing an event entry.
1.3.6.1.4.1.9557.1.4.3.1.2DisplayStringread-onlymandatory
syupsDataRecordInterval
OBJECT-TYPE
The number of minutes to wait between each recording to the data log file.
1.3.6.1.4.1.9557.1.4.4INTEGERread-writemandatory
syupsMaxDataFileLength
OBJECT-TYPE
The maximum length (in bytes) of the data log file. UPS software will cut the first half of the file whenever the file exceeds this maximum length.
1.3.6.1.4.1.9557.1.4.5INTEGERread-writemandatory
syupsDataNumRecords
OBJECT-TYPE
The total number of records in the data log file.
1.3.6.1.4.1.9557.1.4.6INTEGERread-onlymandatory
syupsDataTable
OBJECT-TYPE
A list of data entries. Each entry represents a record in the data log file.
1.3.6.1.4.1.9557.1.4.7not-accessiblemandatory
syupsDataEntry
OBJECT-TYPE
An entry representing a record in the data log file.
1.3.6.1.4.1.9557.1.4.7.1not-accessiblemandatory
syupsDataIndex
OBJECT-TYPE
The record number of a data entry.
1.3.6.1.4.1.9557.1.4.7.1.1INTEGERread-onlymandatory
syupsDataRecord
OBJECT-TYPE
The string containing a data entry.
1.3.6.1.4.1.9557.1.4.7.1.2DisplayStringread-onlymandatory
syupsHistoryOperator
OBJECT-TYPE
The operator which is used to operate on the history file. The command format is 'Command, File, Range'. So far, Command can be PURGE, File can be EVENT or DATA, and Range can be ALL or 'mm/dd/year..mm/dd/year'. For example, 'PURGE, EVENT, ALL' tells the UPS software to purge all entries in the event log file. And 'PURGE, DATA, 03/20/1995..07/02/1995' tells the UPS software to purge the entries which are recorded form 03/20/1995 to 07/20/1995 from the event log file.
1.3.6.1.4.1.9557.1.4.8DisplayStringread-writemandatory
syupsScopeSettings
OBJECT-TYPE
The string contains the settings for UPS Scope Chart, including Value Original Point, Value Unit, Time Unit, Time Interval, and Display Items. The format for the settings string is '%d, %d, %d, %d, %d'. Display Items can be any one or any combination of the following items: SCOPE_INPUT_VOLT 0x0001 SCOPE_OUTPUT_VOLT 0x0010 SCOPE_INPUT_FREQ 0x0100 SCOPE_OUTPUT_FREQ 0x1000
1.3.6.1.4.1.9557.1.4.9DisplayStringread-writemandatory
syupsSchedule
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.5
syupsNoSchEntries
OBJECT-TYPE
The total number of schedule entries.
1.3.6.1.4.1.9557.1.5.1INTEGERread-onlymandatory
syupsSchOperator
OBJECT-TYPE
The operator which is used to operate on the schedule table. There are three commands: 1. 'ADD: action, mm/dd/yyyy, hh:mm:ss, week_day, repeat' indicates to add a new entry to the schedule list. 2. 'REPLACE: i, action, mm/dd/yyyy, hh:mm:ss, week_day, repeat' indicates to replace the i-th entry in the table with the new settings. 3. 'DELETE:n1, n2' indicates to delete the entries ranging from number n1 to number n2 from the schedule table. 'action' could be the following: General System Test (1) Quick Battery Test (2) Deep Battery Test (3) Turn On UPS (11) Turn Off UPS (21) Turn On Outlet (100+x) Turn Off Outlet (200+x) where x indicates the outlet number. 'mm/dd/year' and 'hh:mm:ss' specify the action's starting time. 'repeat' indicates the frequency of the action, it could be Once(1), Daily(2), Weekly(3) and Monthly(4). 'week_day' indicating the day of week is meaningful only when the repeat is set to Weekly, and it could be Sun(0), Mon(1), ..., and Sat(6). For example, '1, 07/08/1994, 15:30:00, 0, 4' indicates that the UPS will do a General System Test at 3:30 PM every month from July 8, 1994. '203, 06/20/1995, 07:00:00, 0, 1' indicates that the UPS will turn off outlet #3 at 7 o'clock on June 20, 1995 and do it only once.
1.3.6.1.4.1.9557.1.5.2DisplayStringread-writemandatory
syupsSchTable
OBJECT-TYPE
A list of schedule entries.
1.3.6.1.4.1.9557.1.5.3not-accessiblemandatory
syupsSchEntry
OBJECT-TYPE
A schedule entry.
1.3.6.1.4.1.9557.1.5.3.1not-accessiblemandatory
syupsSchIndex
OBJECT-TYPE
The entry number of a schedule setting.
1.3.6.1.4.1.9557.1.5.3.1.1INTEGERread-onlymandatory
syupsSchStartDate
OBJECT-TYPE
The starting date (mm/dd/yyyy) of the schedule entry.
1.3.6.1.4.1.9557.1.5.3.1.2DisplayStringread-onlymandatory
syupsSchStartTime
OBJECT-TYPE
The starting time (hh:mm:ss) of the schedule entry.
1.3.6.1.4.1.9557.1.5.3.1.3DisplayStringread-onlymandatory
syupsSchWeekDay
OBJECT-TYPE
The starting day of week for the schedule entry. It could be Sun(0), Mon(1), ..., and Sat(6). It is used when syupsSchRepeat is set to weekly.
1.3.6.1.4.1.9557.1.5.3.1.4INTEGER {sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6)}read-onlymandatory
syupsSchAction
OBJECT-TYPE
The action of the schedule entry. It could be: General System Test (1) Quick Battery Test (2) Deep Battery Test (3) Turn On UPS (11) Turn Off UPS (21) Turn On Outlet (100+x) Turn Off Outlet (200+x) where x indicates the outlet number.
1.3.6.1.4.1.9557.1.5.3.1.5INTEGERread-onlymandatory
syupsSchRepeat
OBJECT-TYPE
It indicates the frequency of the action, it could be Once(1), Daily(2), Weekly(3) and Monthly(4).
1.3.6.1.4.1.9557.1.5.3.1.6INTEGER {once(1), daily(2), weekly(3), monthly(4)}read-onlymandatory
syupsCoworker
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.6
syupsNoAccessControl
OBJECT-TYPE
The total number of access control entries.
1.3.6.1.4.1.9557.1.6.1INTEGERread-onlymandatory
syupsAccessControlOperator
OBJECT-TYPE
The operator which is used to operate on the access control table. There are three commands: 1. 'ADD: community' indicates to add a new entry to the access control list. 2. 'REPLACE: x, community' indicates to replace the x-th entry in the table with the new settings. 3. 'DELETE:n1, n2' indicates to delete the entries from number n1 to number n2 from the access control table.
1.3.6.1.4.1.9557.1.6.2DisplayStringread-writemandatory
syupsAccessControlTable
OBJECT-TYPE
A list of access control entries. Only entries in this list can have access to the agent.
1.3.6.1.4.1.9557.1.6.3not-accessiblemandatory
syupsAccessControlEntry
OBJECT-TYPE
An access control entry.
1.3.6.1.4.1.9557.1.6.3.1not-accessiblemandatory
syupsAccessControlIndex
OBJECT-TYPE
The entry number of a access control setting.
1.3.6.1.4.1.9557.1.6.3.1.1INTEGERread-onlymandatory
syupsAccessControlSetting
OBJECT-TYPE
A string containing the community name.
1.3.6.1.4.1.9557.1.6.3.1.2DisplayStringread-onlymandatory
syupsNoTrapReceiver
OBJECT-TYPE
The total number of trap receiver entries.
1.3.6.1.4.1.9557.1.6.4INTEGERread-onlymandatory
syupsTrapReceiverOperator
OBJECT-TYPE
The operator which is used to operate on the trap receiver table. There are three commands: 1. 'ADD: ipAddress' indicates to add a new entry to the trap receiver list. 2. 'REPLACE: x, ipAddress' indicates to replace the x-th entry in the table with the new settings. 3. 'DELETE:n1, n2' indicates to delete the entries from number n1 to number n2 from the trap receiver table.
1.3.6.1.4.1.9557.1.6.5DisplayStringread-writemandatory
syupsTrapReceiverTable
OBJECT-TYPE
A list of trap receiver entries. When an important event occurs, the agent will send traps to all the entries in the list.
1.3.6.1.4.1.9557.1.6.6not-accessiblemandatory
syupsTrapReceiverEntry
OBJECT-TYPE
An trap receiver entry.
1.3.6.1.4.1.9557.1.6.6.1not-accessiblemandatory
syupsTrapReceiverIndex
OBJECT-TYPE
The entry number of a trap receiver setting.
1.3.6.1.4.1.9557.1.6.6.1.1INTEGERread-onlymandatory
syupsTrapReceiverSetting
OBJECT-TYPE
A string containing a trap receiver's IP address.
1.3.6.1.4.1.9557.1.6.6.1.2DisplayStringread-onlymandatory
syupsTraps
OBJECT-IDENTITY
1.3.6.1.4.1.9557.1.7

Notifications

NameOIDStatus
syupsTrapOverTemperature
NOTIFICATION-TYPE
The battery temperature is too high. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.1current
syupsTrapOverCurrent
NOTIFICATION-TYPE
The current is too high. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.2current
syupsTrapOverVoltage
NOTIFICATION-TYPE
The voltage is too high. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.3current
syupsTrapUnderVoltage
NOTIFICATION-TYPE
The voltage is too low. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.4current
syupsOffFrequency
NOTIFICATION-TYPE
The frequency is abnormal. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.5current
syupsLowBattery
NOTIFICATION-TYPE
The battery is too low. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.6current
syupsBadBattery
NOTIFICATION-TYPE
The battery is bad. This trap is persistent and is resent at one minute intervals until the UPS either turns off or the status is no longer present.
1.3.6.1.4.1.9557.1.7.7current