SUPERMICRO-HEALTH-MIB
- Registered at
- 1.3.6.1.4.1.10876.2.1
- Last updated
- 2001-10-26 00:00
- Organization
- Super Micro Computer Inc.
- Namespace
- supermicro
- Source file
SUPERMICRO-HEALTH-MIB- Digest
sha256:55c3d39cea743c75d310f92b595a609680b9efc85dc2465c8e40e940c9c52c02
Description
MIB module for monitoring health information
Contact
Software Lab Postal: 980 Rock Avenue San Jose, CA 95131 USA Tel: +1 408 503 8000 E-mail: SoftLab@supermicro.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
| SUPERMICRO-SMI | smHealth |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC SUPERMICRO-HEALTH-MIB SUPERMICRO-SMI
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| SMHealthInfoTypes TEXTUAL-CONVENTION Represents the different types of health information that may be present in a managed device. The following health information types are currently predefined: 0: fan speed 1: voltage 2: temperature | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| smHealthObjects OBJECT-IDENTITY | 1.3.6.1.4.1.10876.2.1.1 | |||
| smHealthMonitorTable OBJECT-TYPE A table of health monitoring entries. | 1.3.6.1.4.1.10876.2.1.1.1 | not-accessible | current | |
| smHealthMonitorEntry OBJECT-TYPE An entry in the health monitoring table. Entries cannot be created or deleted via SNMP operations. | 1.3.6.1.4.1.10876.2.1.1.1.1 | not-accessible | current | |
| smHealthMonitorIndex OBJECT-TYPE The unique value identifies this Monitor device. | 1.3.6.1.4.1.10876.2.1.1.1.1.1 | Integer32 (1..65535) | not-accessible | current |
| smHealthMonitorName OBJECT-TYPE A textual full name assigned to the Monitor device. This object is suitable for output to a human operator. | 1.3.6.1.4.1.10876.2.1.1.1.1.2 | DisplayString | read-only | current |
| smHealthMonitorType OBJECT-TYPE Identifies this Monitor device type. | 1.3.6.1.4.1.10876.2.1.1.1.1.3 | SMHealthInfoTypes | read-only | current |
| smHealthMonitorReading OBJECT-TYPE Indicates the reading value for the Monitor device that are currently in use on the managed device. FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are displayed in Celsius. | 1.3.6.1.4.1.10876.2.1.1.1.1.4 | Integer32 (0..65535) | read-only | current |
| smHealthMonitorHighLimit OBJECT-TYPE Indicates the the High limit for the Monitor device that are currently in use on the managed device. This is applied to Temperature and Voltage devices only. Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius. | 1.3.6.1.4.1.10876.2.1.1.1.1.5 | Integer32 (0..65535) | read-write | current |
| smHealthMonitorLowLimit OBJECT-TYPE Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device. FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius. | 1.3.6.1.4.1.10876.2.1.1.1.1.6 | Integer32 (0..65535) | read-write | current |
| smHealthMonitorMaxReading OBJECT-TYPE Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device. FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are in Celsius. | 1.3.6.1.4.1.10876.2.1.1.1.1.7 | Integer32 (0..65535) | read-only | current |
| smHealthMonitorMinReading OBJECT-TYPE Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device. FAN readings are displayed in RPM. Voltage readings are displayed in mV. Temperture readings are displayed in Celsius. | 1.3.6.1.4.1.10876.2.1.1.1.1.8 | Integer32 (0..65535) | read-only | current |
| smHealthMonitorDivisor OBJECT-TYPE Indicates the value for the Divisor for the Fan device that are currently in use on the managed device. This is applied to Fan devices only. | 1.3.6.1.4.1.10876.2.1.1.1.1.9 | Integer32 | read-write | current |
| smHealthMonitorMonitor OBJECT-TYPE Indicates the monitoring status for the Fan device that are currently in use on the managed device. 0 = not monitored, 1 = monitored. | 1.3.6.1.4.1.10876.2.1.1.1.1.10 | TruthValue | read-write | current |
| smHealthMonitorReadingUnit OBJECT-TYPE Indicates the reading unit of the monitor device. | 1.3.6.1.4.1.10876.2.1.1.1.1.11 | DisplayString | read-only | current |
| smHealthMonitorStatus OBJECT-TYPE Indicates the status of the monitor device. Values: 0: OK 1: Warning 2: Critical | 1.3.6.1.4.1.10876.2.1.1.1.1.12 | Integer32 | read-only | current |
| smHealthNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.10876.2.1.2 | |||
| smHealthConformance OBJECT-IDENTITY | 1.3.6.1.4.1.10876.2.1.3 | |||
| smHealthCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.10876.2.1.3.1 | |||
| smHealthGroups OBJECT-IDENTITY | 1.3.6.1.4.1.10876.2.1.3.2 | |||
| smHealthAllinoneStatus OBJECT-TYPE Indicates the all-in-one status of the monitoring items. Values: 0: OK 1: Warning 2: Critical | 1.3.6.1.4.1.10876.2.2 | Integer32 | read-only | current |
| smHealthAllinoneMsg OBJECT-TYPE The all-in-one status message of the monitoring items. | 1.3.6.1.4.1.10876.2.3 | DisplayString | read-only | current |
Conformance
| Name | OID | Status |
|---|---|---|
| smHealthCompliance MODULE-COMPLIANCE The compliance statement for entities which implement the Supermicro Health Monitoring MIB | 1.3.6.1.4.1.10876.2.1.3.1.1 | current |
| smHealthMonitorGroup OBJECT-GROUP A collection of objects providing Monitor devices. | 1.3.6.1.4.1.10876.2.1.3.2.1 | current |