SSU2000-MIB

Registered at
1.3.6.1.4.1.601.3.1.1
Last updated
1908-01-14 00:00
Organization
Symmetricom
Namespace
microsemi
Source file
SSU2000-MIB
Digest
sha256:eec5a4f78615df3982bfadfdf0cce1390f286fcd244828970e64d0beedf2e72a

Description

Private MIB module for management of SSU2000. This SSU2000 private MIB supports all existing functions of the SSU2000 thus achieving full system control via this software interface. All reports, queries, autonomous messages, control, provisioning and administration (except for Set User ID/password/level, Set IP assignments, Reset Connection and SNMP Community Settings) will be addressable via SNMP.

Contact

Symmetricom Technical Support 1-888-367-7966 toll free USA 1-408-428-7907 worldwide Support@symmetricom.com

Imports

FromSymbols
DATUM-MIBaustron
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DATUM-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
SSU2000-MIB

Textual conventions

NameOIDSyntaxAccessStatus
ActiveValue
type
DateAndTime
TEXTUAL-CONVENTION
A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present.
current
EnaValue
type
OkValue
type
OnValue
type
TAntHeight
TEXTUAL-CONVENTION
antenna height specification. field octets contents range ----- ------ -------- ----- 1 1 +/- '+' / '-' 2 2-3 meter 0..10000 3 4 meter fraction 0..99 +/- hh.hh
current
TLatAndLon
TEXTUAL-CONVENTION
antenna latitude and longitude specification. field octets contents range ----- ------ -------- ----- 1 1 +/-180 deg '+' / '-' 2 2 degree 0..180 3 3 minute 0..59 4 4 second 0..59 5 5 second fraction 0..99 +/- dd:mm:ss.ss
current
TLocalTimeOffset
TEXTUAL-CONVENTION
A local time offset specification. field octets contents range ----- ------ -------- ----- 1 1 direction from UTC '+' / '-' 2 2 hours from UTC* 0..13 3 3 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - The hours range is 0..13 For example, the -6 local time offset would be displayed as: -6:0
current
TModuleCode
TEXTUAL-CONVENTION
The module hex code 1001 Input – 3 Port 1002 Input – 1 Port 1003 Input – DS1 3 Port 1004 Input – DS1 1 Port 1005 Input – E1 3 Port 1006 Input – E1 1 Port 1008 Input – GPS 1010 Input – Composite Clock (1 Port) 1012 Input – Japanese CC (1 Port) 1013 Input – Japanese Sine (3 Port) 2001 Clock – Stratum 2E Rubidium 2002 Clock – Stratum 3E 2003 Clock – Type I 3001 Communication Module 4001 Output – DS1 4002 Output – E1 4003 Output – Composite Clock 4004 Output – 2048 kHz 4007 Output – EIA 422 4008 Output – E1/2048 kHz 4009 DS1 Line Retiming Module 4 Ports 400A DS1 Line Retiming Module 2 Ports 400B Output – Japanese CC 400C Output – Japanese Sine 400D E1 Line Retiming Module 4 Ports 4021 NTP Blade 4022 PTP Blade 5001 Buffer Card
current
TSsm
TEXTUAL-CONVENTION
The ssm hex code
current
TrueValue
type
ValidValue
type
YesValue
type

Objects

NameOIDSyntaxAccessStatus
inventory
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.1
inventoryTable
OBJECT-TYPE
A list containing the system inventory of installed hardware and software components contained in the SSU-2000. The number of entries is given by the values of inChassis and inSlot.
1.3.6.1.4.1.601.3.1.1.1.1not-accessiblecurrent
inEntry
OBJECT-TYPE
The Inventory table contains inventory information for all modules installed in the SSU2000 unit. System Inventory attributes.
1.3.6.1.4.1.601.3.1.1.1.1.1not-accessiblecurrent
inChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.1.1.1.1INTEGER (1..5)not-accessiblecurrent
inSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.1.1.1.2INTEGER (1..20)not-accessiblecurrent
inModCode
OBJECT-TYPE
Reports module type is identified with a Hex value.
1.3.6.1.4.1.601.3.1.1.1.1.1.3TModuleCoderead-onlycurrent
inName
OBJECT-TYPE
Reports module type is identified with a Name.
1.3.6.1.4.1.601.3.1.1.1.1.1.4DisplayString (SIZE(0..20))read-onlycurrent
inSerial
OBJECT-TYPE
Reports module's serial number.
1.3.6.1.4.1.601.3.1.1.1.1.1.5DisplayString (SIZE(0..20))read-onlycurrent
inService
OBJECT-TYPE
Reports module's in-service time.
1.3.6.1.4.1.601.3.1.1.1.1.1.6DateAndTimeread-onlycurrent
inHwPart
OBJECT-TYPE
Reports module's hardware part number.
1.3.6.1.4.1.601.3.1.1.1.1.1.7DisplayString (SIZE(0..14))read-onlycurrent
inHwRev
OBJECT-TYPE
Reports module's hardware revision.
1.3.6.1.4.1.601.3.1.1.1.1.1.8DisplayString (SIZE(0..10))read-onlycurrent
inHwDate
OBJECT-TYPE
Reports module's date of manufacture.
1.3.6.1.4.1.601.3.1.1.1.1.1.9DateAndTimeread-onlycurrent
inSwPart
OBJECT-TYPE
Reports module's software part number.
1.3.6.1.4.1.601.3.1.1.1.1.1.10DisplayString (SIZE(0..14))read-onlycurrent
inSwRev
OBJECT-TYPE
Reports module's main software revision.
1.3.6.1.4.1.601.3.1.1.1.1.1.11DisplayString (SIZE(0..10))read-onlycurrent
inRevision
OBJECT-TYPE
Reports module's software and PLD revisions.
1.3.6.1.4.1.601.3.1.1.1.1.1.12DisplayString (SIZE(0..60))read-onlycurrent
inShelfDesc
OBJECT-TYPE
Reports shelf type description.
1.3.6.1.4.1.601.3.1.1.1.1.1.13DisplayString (SIZE(0..20))read-onlycurrent
inShelfPart
OBJECT-TYPE
Reports shelf part number.
1.3.6.1.4.1.601.3.1.1.1.1.1.14DisplayString (SIZE(0..14))read-onlycurrent
inInstalled
OBJECT-TYPE
Reports if this module is physically installed in the system or not. 1 = module is installed. 2 = module is physically absent, but the configuration data is still there.
1.3.6.1.4.1.601.3.1.1.1.1.1.15YesValueread-onlycurrent
inAction
OBJECT-TYPE
User Action: ENABLE (1), enables the module. DISABLE (2), marks a module as inactive to be removed from the system. REMOVE (3), if physically absent, the module is removed from the registry. Note: This field only is meaningful during the write operation. When read, it always displayed as 1.
1.3.6.1.4.1.601.3.1.1.1.1.1.16INTEGER {enable(1), disable(2), remove(3)}read-writecurrent
inAdapterPart
OBJECT-TYPE
Reports the Symmetricom input adapter part number. Note: If this field is an empty string, it means the input adapter identification is not applicable for this module.
1.3.6.1.4.1.601.3.1.1.1.1.1.17DisplayString (SIZE(0..14))read-onlycurrent
inFeatureTable
OBJECT-TYPE
The SSU-2000 has two optional features, NTP and SNMP. The Feature Presence table provides presence of these features.
1.3.6.1.4.1.601.3.1.1.1.2not-accessiblecurrent
inFeatureEntry
OBJECT-TYPE
inFeatureIndex The index to identify the feature inFeature The setting of the feature
1.3.6.1.4.1.601.3.1.1.1.2.1not-accessiblecurrent
inFeatureIndex
OBJECT-TYPE
A unique value for each feature table. 1 = NTP 2 = SNMP
1.3.6.1.4.1.601.3.1.1.1.2.1.1INTEGER (1..2)not-accessiblecurrent
inFeature
OBJECT-TYPE
Reports SSU-2000 feature set: 1 = Enabled 2 = Disabled
1.3.6.1.4.1.601.3.1.1.1.2.1.2EnaValueread-onlycurrent
mstatus
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2
statusCom
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.1
statusClk
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.2
staClkTable
OBJECT-TYPE
Reports Clock Module Status, loop mode, tau, and system-level priority quality level (pql).
1.3.6.1.4.1.601.3.1.1.2.2.1not-accessiblecurrent
staCkEntry
OBJECT-TYPE
Clock Status Attributes:
1.3.6.1.4.1.601.3.1.1.2.2.1.1not-accessiblecurrent
staCkChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.2.1.1.1INTEGER (1)not-accessiblecurrent
staCkSlot
OBJECT-TYPE
Identifies which slot is being addressed. This slot number and chassis number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for Clocks are slot 1 and slot 12.
1.3.6.1.4.1.601.3.1.1.2.2.1.1.2INTEGER (1..20)not-accessiblecurrent
staCkStatus
OBJECT-TYPE
Reports the clock module status. ok(1), -- module is enabled and operating without faults selected(2), -- module is enabled and selected as primary local oscillator disable(3), -- module is disabled fault(4) -- module is enabled and operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.2.1.1.3INTEGER {ok(1), selected(2), disable(3), fault(4)}read-onlycurrent
staCkPLLMode
OBJECT-TYPE
Reports the clock software Phase Locked Loop (PLL) Mode. failed(1), -- pll hardware failure, pll unlocked warmup(2), -- local oscillator is initialized and warming up acquire(3), -- LO is operating in acquire or fast locked mode holdover(4), -- LO is operating in holdover due to lose or reference input lock(5) -- LO is operating in normal mode
1.3.6.1.4.1.601.3.1.1.2.2.1.1.4INTEGER {failed(1), warmup(2), acquire(3), holdover(4), lock(5)}read-onlycurrent
staCkTau
OBJECT-TYPE
Reports the clock tau value. The tau is the time constant (in seconds) used by the clock's servo control loop.
1.3.6.1.4.1.601.3.1.1.2.2.1.1.5Counter32read-onlycurrent
staCkPql
OBJECT-TYPE
Reports the system Priority Quality Level (PQL). The PQL indicates the Stratum Level of the clock. Zero indicates an invalid SSM was read.
1.3.6.1.4.1.601.3.1.1.2.2.1.1.6INTEGER (0 | 1..16)read-onlycurrent
staCkUtc
OBJECT-TYPE
Reports the clock has been TOD synced with GPS or PackeTime..
1.3.6.1.4.1.601.3.1.1.2.2.1.1.7YesValueread-onlycurrent
statusGps
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.5
staGpsTable
OBJECT-TYPE
The GPS Input Module Status reports the module's current status, input port phase data, time status, MTIE threshold status, frequency threshold status, and TIE measurement statistics status.
1.3.6.1.4.1.601.3.1.1.2.5.1not-accessiblecurrent
staGpsEntry
OBJECT-TYPE
GPS Status Attributes: staGpsChassis Identifies which chassis is being addressed stGpskSlot Identifies which slot is being addressed staGpsMStatus Reports module status staGpsStatus Reports gps input port status staGpsPhaseA Reports phase value versus clock A in nano-seconds. staGpsPhaseB Reports phase value versus clock B in nano-seconds. staGpsUtc Reports number tells us whether the GPS module has UTC time or not. staGpsMtie1A Reports which MTIE limit 1 threshold was exceeded on clock A. staGpsMtie2A Reports which MTIE limit 2 threshold was exceeded on clock A. staGpsMtie1B Reports which MTIE limit 1 threshold was exceeded on clock B. staGpsMtie2B Reports which MTIE limit 2 threshold was exceeded on clock B. staGpsFreqA Reports input port frequency threshold exceeded on clock A. staGpsFreqB Reports input port frequency threshold exceeded on clock B. staGpsPpsSigma Reports sigma (statistical) calculation representing noise variation on the GPS 1PPS staGps3Sigma Reports 3sigma (statistical) calculation representing noise variation on the GPS 1PPS
1.3.6.1.4.1.601.3.1.1.2.5.1.1not-accessiblecurrent
staGpsChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.5.1.1.1INTEGER (1)not-accessiblecurrent
staGpsSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.2INTEGER (1..20)not-accessiblecurrent
staGpsStatus
OBJECT-TYPE
The GPS port status. ok(1), -- module is enabled and operating without faults selected(2), -- module is enabled and selected as input reference disable(3), -- module is disabled fault(4), -- module is enabled and operating with faults reject(5) -- module is rejected due to antenna failure
1.3.6.1.4.1.601.3.1.1.2.5.1.1.3INTEGER {ok(1), selected(2), disable(3), fault(4), reject(5)}read-onlycurrent
staGpsPhaseA
OBJECT-TYPE
The phase value versus clock A. The phaseA is the current 1 second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.4INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staGpsPhaseB
OBJECT-TYPE
Reports phase value versus clock B. The phaseB is the current 1 second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.5INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staGpsUtc
OBJECT-TYPE
Reports the GPS module has been set to UTC time (or not). 1 = time is available 2 = time is not available
1.3.6.1.4.1.601.3.1.1.2.5.1.1.6YesValueread-onlycurrent
staGpsMStatus
OBJECT-TYPE
Reports the GPS module status. ok(1), -- module is enabled and operating normally disable(2), -- module is disabled fault(3) -- module is enabled, but not operational due to faults
1.3.6.1.4.1.601.3.1.1.2.5.1.1.7INTEGER {ok(1), disable(2), fault(3)}read-onlycurrent
staGpsMtie1A
OBJECT-TYPE
Reports which MTIE limit 1 threshold was exceeded on clock A. If ok, it means no error for MTIE limit 1 on clock A. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 1 threshold was exceeded on clock A.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.8INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staGpsMtie2A
OBJECT-TYPE
Reports which MTIE limit 2 threshold was exceeded on clock A. If ok, it means no error for MTIE limit 2 on clock A. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 2 threshold was exceeded on clock A.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.9INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staGpsMtie1B
OBJECT-TYPE
Reports which MTIE limit 1 threshold was exceeded on clock B. If ok, it means no error for MTIE limit 1 on clock B. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 1 threshold was exceeded on clock B.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.10INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staGpsMtie2B
OBJECT-TYPE
Reports which MTIE limit 2 threshold was exceeded on clock B. If ok, it means no error for MTIE limit 2 on clock B. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 2 threshold was exceeded on clock B.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.11INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staGpsFreqA
OBJECT-TYPE
Reports the input port frequency threshold exceeded on clock A.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.12OkValueread-onlycurrent
staGpsFreqB
OBJECT-TYPE
Reports the input port frequency threshold exceeded on clock B.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.13OkValueread-onlycurrent
staGpsPpsSigma
OBJECT-TYPE
Reports current 1 PPS Sigma.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.14DisplayString (SIZE(0..32))read-onlycurrent
staGps3Sigma
OBJECT-TYPE
Reports current 3 Sigma Threshold.
1.3.6.1.4.1.601.3.1.1.2.5.1.1.15DisplayString (SIZE(0..32))read-onlycurrent
stGpsPosTable
OBJECT-TYPE
The GPS attributes that report the status of the GPS engine's position and status
1.3.6.1.4.1.601.3.1.1.2.5.2not-accessiblecurrent
stGpsPosEntry
OBJECT-TYPE
The GPS position attributes: stGpsPosChassis Identifies which chassis is being addressed stGpsPosSlot Identifies which slot is being addressed stGpsPosValid Reports if the GPS position is valid or not. stGpsPosLat Reports antenna latitude position of the GPS module. stGpsPosLon Reports antenna longitude position of the GPS module. stGpsPosHgt Reports antenna height (meter) position of the GPS module. stGpsPosAccurate Reports antenna position accuracy stGpsPosPdop Reports PDOP assigns a value of accuracy to the calculated position. stGpsPosAvg Reports position averaging value indicates how many position values are used to determine position.
1.3.6.1.4.1.601.3.1.1.2.5.2.1not-accessiblecurrent
stGpsPosChassis
OBJECT-TYPE
Identifies which shelf is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.5.2.1.1INTEGER (1)not-accessiblecurrent
stGpsPosSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
1.3.6.1.4.1.601.3.1.1.2.5.2.1.2INTEGER (1..20)not-accessiblecurrent
stGpsPosValid
OBJECT-TYPE
Reports if the GPS position is valid or not. 1 = valid 2 = invalid
1.3.6.1.4.1.601.3.1.1.2.5.2.1.3ValidValueread-onlycurrent
stGpsPosLat
OBJECT-TYPE
Reports antenna latitude position of the GPS module. The format is +dd:mm:ss.ss or -dd:mm:ss.ss The latitude is +/- 90 deg.
1.3.6.1.4.1.601.3.1.1.2.5.2.1.4TLatAndLonread-onlycurrent
stGpsPosLon
OBJECT-TYPE
Reports antenna longitude position of the GPS module. The format is +dd:mm:ss.ss or -dd:mm:ss.ss The longitude is +/- 180 deg.
1.3.6.1.4.1.601.3.1.1.2.5.2.1.5TLatAndLonread-onlycurrent
stGpsPosHgt
OBJECT-TYPE
Reports antenna height (meter) position of the GPS module. The format is +hh.hh or -hh.hh The height is +/- 10000.0 meters.
1.3.6.1.4.1.601.3.1.1.2.5.2.1.6TAntHeightread-onlycurrent
stGpsPosAccurate
OBJECT-TYPE
Reports antenna position accuracy APPROX - position is not accurate D2 - position is accurate, 2D, height is not valid D3 - position is accurate, 3D, height is valid
1.3.6.1.4.1.601.3.1.1.2.5.2.1.7INTEGER {approx(1), d2(2), d3(3)}read-onlycurrent
stGpsPosPdop
OBJECT-TYPE
Reports PDOP indicates position precision as an integer representation of value in tenths. For example, the value 19 means 1.9 pdop. if zero, it means invalid.
1.3.6.1.4.1.601.3.1.1.2.5.2.1.8INTEGER (0..100)read-onlycurrent
stGpsPosAvg
OBJECT-TYPE
Reports satellite position averaging value. If zero, the satellite position is user entered.
1.3.6.1.4.1.601.3.1.1.2.5.2.1.9INTEGER (0..3600)read-onlycurrent
stGpsAvailTable
OBJECT-TYPE
A list of GPS satellite availability, reports the location of visible satellites.
1.3.6.1.4.1.601.3.1.1.2.5.3not-accessiblecurrent
stGpsAvEntry
OBJECT-TYPE
GPS Availability attributes:
1.3.6.1.4.1.601.3.1.1.2.5.3.1not-accessiblecurrent
stGpsAvChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.5.3.1.1INTEGER (1)not-accessiblecurrent
stGpsAvSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
1.3.6.1.4.1.601.3.1.1.2.5.3.1.2INTEGER (1..20)not-accessiblecurrent
stGpsAvChnl
OBJECT-TYPE
Reports satellite channel number.
1.3.6.1.4.1.601.3.1.1.2.5.3.1.3INTEGER (1..32)not-accessiblecurrent
stGpsAvPNCode
OBJECT-TYPE
Reports satellite PN code.
1.3.6.1.4.1.601.3.1.1.2.5.3.1.4INTEGER (0..99)read-onlycurrent
stGpsAvElevation
OBJECT-TYPE
Reports calculated elevation (in degrees) of the satellite.
1.3.6.1.4.1.601.3.1.1.2.5.3.1.5INTEGER (0..90)read-onlycurrent
stGpsAvAzimuth
OBJECT-TYPE
Reports calculated Azimuth (in degrees) of the satellite.
1.3.6.1.4.1.601.3.1.1.2.5.3.1.6INTEGER (0..360)read-onlycurrent
stGpsAvHealthy
OBJECT-TYPE
Reports current health of the satellite. 1 = healthy 2 = unhealthy
1.3.6.1.4.1.601.3.1.1.2.5.3.1.7YesValueread-onlycurrent
stGpsTrackTable
OBJECT-TYPE
A list of GPS satellites being tracked show with visibility, signal strength, & health information.
1.3.6.1.4.1.601.3.1.1.2.5.5not-accessiblecurrent
stGpsTkEntry
OBJECT-TYPE
A entry GPS attributes.
1.3.6.1.4.1.601.3.1.1.2.5.5.1not-accessiblecurrent
stGpsTkChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.5.5.1.1INTEGER (1)not-accessiblecurrent
stGpsTkSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
1.3.6.1.4.1.601.3.1.1.2.5.5.1.2INTEGER (1..20)not-accessiblecurrent
stGpsTkChnl
OBJECT-TYPE
Reports satellite channel number.
1.3.6.1.4.1.601.3.1.1.2.5.5.1.3INTEGER (1..32)not-accessiblecurrent
stGpsTkSv
OBJECT-TYPE
Reports satellite vehicle number being tracked. if zero, it is invalid
1.3.6.1.4.1.601.3.1.1.2.5.5.1.4INTEGER (0 | 1..32)read-onlycurrent
stGpsTkSnr
OBJECT-TYPE
Reports signal-to-noise ration number being reported if zero, it is invalid
1.3.6.1.4.1.601.3.1.1.2.5.5.1.5INTEGER (0 | 1..255)read-onlycurrent
stGpsTkStatus
OBJECT-TYPE
Reports tracking status. src (1), -- search acq (2), -- acquire agc (3), -- automatic gain control frq (4), -- frequency locking cod (5), -- code locking msg (6), -- messaging tim (7), -- setting time eph (8), -- retriving ephemeris data ok (9) -- satellite being used in the timing solution
1.3.6.1.4.1.601.3.1.1.2.5.5.1.6INTEGER {src(1), acq(2), agc(3), frq(4), cod(5), msg(6), tim(7), eph(8), ok(9)}read-onlycurrent
statusDs1E1Inp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.7
staDs1E1InpTable
OBJECT-TYPE
A list of DS1/E1 Input status entries.
1.3.6.1.4.1.601.3.1.1.2.7.2not-accessiblecurrent
staDiEntry
OBJECT-TYPE
Input port status attributes.
1.3.6.1.4.1.601.3.1.1.2.7.2.1not-accessiblecurrent
staDiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.7.2.1.1INTEGER (1)not-accessiblecurrent
staDiSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.2INTEGER (1..20)not-accessiblecurrent
staDiPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.3INTEGER (1..3)not-accessiblecurrent
staDiStatus
OBJECT-TYPE
Reports input port status. ok(1), -- port is enabled & operating without faults selected(2), -- port is selected as system reference disable(3), -- port is diabled fault(4) -- port is enabled & operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.7.2.1.4INTEGER {ok(1), selected(2), disable(3), fault(4)}read-onlycurrent
staDiPhaseA
OBJECT-TYPE
Reports input phase value versus clock A. The phaseA is the current 1 second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.5INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staDiPhaseB
OBJECT-TYPE
Reports input phase value versus clock B. The phaseB is the current 1 second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.6INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staDiPql
OBJECT-TYPE
Reports input port Priority Quality Level (PQL). The PQL is the current stratum level (read or provisioned) being reported by the port. If zero, it is invalid.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.7INTEGER (0 | 1..16)read-onlycurrent
staDiPqlRcv
OBJECT-TYPE
Reports receiving Sync Status Message (SSM) for the input port state. 1 = enabled 2 = disabled
1.3.6.1.4.1.601.3.1.1.2.7.2.1.8YesValueread-onlycurrent
staDiLOS
OBJECT-TYPE
Reports input port has LOS fault.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.9OkValueread-onlycurrent
staDiAIS
OBJECT-TYPE
Reports input port has AIS fault.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.10OkValueread-onlycurrent
staDiOOF
OBJECT-TYPE
Reports input port has OOF fault.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.11OkValueread-onlycurrent
staDiBPV
OBJECT-TYPE
Reports input port has BPV fault.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.12OkValueread-onlycurrent
staDiCRC
OBJECT-TYPE
Reports input port CRC fault.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.13OkValueread-onlycurrent
staDiMtie1A
OBJECT-TYPE
Reports which MTIE limit 1 threshold was exceeded versus clock A. If ok, it means no error for MTIE limit 1 on clock A. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 1 threshold was exceeded versus clock A.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.14INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staDiMtie2A
OBJECT-TYPE
Reports which MTIE limit 2 threshold was exceeded versus clock A. If ok, it means no error for MTIE limit 2 versus clock A. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 2 threshold was exceeded versus clock A.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.15INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staDiMtie1B
OBJECT-TYPE
Reports which MTIE limit 1 threshold was exceeded verus clock B. If ok, it means no error for MTIE limit 1 versus clock B. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 1 threshold was exceeded versus clock B.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.16INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staDiMtie2B
OBJECT-TYPE
Reports which MTIE limit 2 threshold was exceeded versus clock B. If ok, it means no error for MTIE limit 2 versus clock B. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 2 threshold was exceeded versus clock B.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.17INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staDiFreqA
OBJECT-TYPE
Reports input port frequency threshold exceeded versus clock A.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.18OkValueread-onlycurrent
staDiFreqB
OBJECT-TYPE
Reports input port frequency threshold exceeded versus clock B.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.19OkValueread-onlycurrent
staLOSErCnt
OBJECT-TYPE
Reports input port LOS error count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.20Counter32read-onlycurrent
staLOSClCnt
OBJECT-TYPE
Reports input port LOS clear count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.21Counter32read-onlycurrent
staAISErCnt
OBJECT-TYPE
Reports input port AIS error count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.22Counter32read-onlycurrent
staAISClCnt
OBJECT-TYPE
Reports input port AIS clear count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.23Counter32read-onlycurrent
staOOFErCnt
OBJECT-TYPE
Reports input port OOF error count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.24Counter32read-onlycurrent
staOOFClCnt
OBJECT-TYPE
Reports input port OOF clear count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.25Counter32read-onlycurrent
staBPVErCnt
OBJECT-TYPE
Reports input port BPV error count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.26Counter32read-onlycurrent
staBPVClCnt
OBJECT-TYPE
Reports input port BPV clear count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.27Counter32read-onlycurrent
staCRCErCnt
OBJECT-TYPE
Reports input port CRC error count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.28Counter32read-onlycurrent
staCRCClCnt
OBJECT-TYPE
Reports input port CRC clear count.
1.3.6.1.4.1.601.3.1.1.2.7.2.1.29Counter32read-onlycurrent
staDiMStatus
OBJECT-TYPE
The input module status. ok(1), -- module is enabled and operating without faults disable(2), -- module is disabled fault(3) -- module is enabled and operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.7.2.1.30INTEGER {ok(1), disable(2), fault(3)}read-onlycurrent
statusCcInp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.8
staCcInpTable
OBJECT-TYPE
A list of Composite Clock Input status information.
1.3.6.1.4.1.601.3.1.1.2.8.2not-accessiblecurrent
staCiEntry
OBJECT-TYPE
Input port status attributes.
1.3.6.1.4.1.601.3.1.1.2.8.2.1not-accessiblecurrent
staCiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.8.2.1.1INTEGER (1)not-accessiblecurrent
staCiSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.2INTEGER (1..20)not-accessiblecurrent
staCiPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.3INTEGER (1..3)not-accessiblecurrent
staCiStatus
OBJECT-TYPE
Reports input port status. ok(1), -- port is enabled & operating without faults selected(2), -- port is selected as system reference disable(3), -- port is diabled fault(4) -- port is enabled & operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.8.2.1.4INTEGER {ok(1), selected(2), disable(3), fault(4)}read-onlycurrent
staCiPhaseA
OBJECT-TYPE
Reports input phase value versus clock A. The phaseA is the current 1 second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.5INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staCiPhaseB
OBJECT-TYPE
Reports input phase value versus clock B. The phaseB is the current 1 second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.6INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staCiLOS
OBJECT-TYPE
Reports input port has LOS fault.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.9OkValueread-onlycurrent
staCiBPV
OBJECT-TYPE
Reports input port has BPV fault.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.12OkValueread-onlycurrent
staCiLOSErCnt
OBJECT-TYPE
Reports input port LOS error count.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.14Counter32read-onlycurrent
staCiLOSClCnt
OBJECT-TYPE
Reports input port LOS clear count.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.15Counter32read-onlycurrent
staCiBPVErCnt
OBJECT-TYPE
Reports input port BPV error count.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.20Counter32read-onlycurrent
staCiBPVClCnt
OBJECT-TYPE
Reports input port BPV clear count.
1.3.6.1.4.1.601.3.1.1.2.8.2.1.21Counter32read-onlycurrent
staCiMStatus
OBJECT-TYPE
Reports input module status. ok(1), -- module is enabled and operating without faults disable(2), -- module is disabled fault(3) -- module is enabled and operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.8.2.1.24INTEGER {ok(1), disable(2), fault(3)}read-onlycurrent
statusOut
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.10
staOutTable
OBJECT-TYPE
The list of Generic Output status information.
1.3.6.1.4.1.601.3.1.1.2.10.2not-accessiblecurrent
staOtEntry
OBJECT-TYPE
Output port status attributes.
1.3.6.1.4.1.601.3.1.1.2.10.2.1not-accessiblecurrent
staOtChassis
OBJECT-TYPE
Identifies which shelf is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The output module can reside on any chassis (1-5).
1.3.6.1.4.1.601.3.1.1.2.10.2.1.1INTEGER (1..5)not-accessiblecurrent
staOtSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.2INTEGER (1..20)not-accessiblecurrent
staOtStatus
OBJECT-TYPE
Reports output port status. ok(1), -- modlule is enabled & operating without faults disable(3), -- module is diabled fault(4) -- module is enabled & operating with fault(s) reject(5) -- module type is mismatched with redundant module
1.3.6.1.4.1.601.3.1.1.2.10.2.1.3INTEGER {ok(1), disable(3), fault(4), reject(5)}read-onlycurrent
staOtClkSel
OBJECT-TYPE
Reports which clock is selected for generating the output. clka(1), -- Clock A is selected as the Primary clock clkb(2), -- Clock B is selected as the Primary clock clkc(3), -- Clock C is selected as the Primary clock clkd(4), -- Clock D is selected as the Primary clock none(5) -- no clock is selected
1.3.6.1.4.1.601.3.1.1.2.10.2.1.4INTEGER {clka(1), clkb(2), clkc(3), clkd(4), none(5)}read-onlycurrent
staOtClka
OBJECT-TYPE
Reports that clock A is available.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.5ActiveValueread-onlycurrent
staOtClkb
OBJECT-TYPE
Reports that clock B is available.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.6ActiveValueread-onlycurrent
staOtClkc
OBJECT-TYPE
Reports that clock C is available.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.7ActiveValueread-onlycurrent
staOtClkd
OBJECT-TYPE
Reports that clock D is available.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.8ActiveValueread-onlycurrent
staOtRednt
OBJECT-TYPE
Reports the adjacent slot number if this module is the output module redundant pair. If this module is not redundant, zero is reported.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.9INTEGER (0..20)read-onlycurrent
staOtPql
OBJECT-TYPE
Reports the Priority Quality Level (PQL) being generated. If zero, it is invalid or Not Applicable.
1.3.6.1.4.1.601.3.1.1.2.10.2.1.10INTEGER (0 | 1..16)read-onlycurrent
staOtPortSta
OBJECT-TYPE
Reports the status for ports 1-20. 1st digit represents port 1, 20th digit represents port 20 1 = ok 2 = not used 3 = internal port fault 4 = external port fault 5 = fault 6 = squelch
1.3.6.1.4.1.601.3.1.1.2.10.2.1.11OCTET STRING (SIZE(20))read-onlycurrent
statusLrm
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.11
staLrmMTable
OBJECT-TYPE
A list of DS1 LRM module status information.
1.3.6.1.4.1.601.3.1.1.2.11.2not-accessiblecurrent
staLrmMEntry
OBJECT-TYPE
DS1 LRM module status attributes.
1.3.6.1.4.1.601.3.1.1.2.11.2.1not-accessiblecurrent
staLrmMChassis
OBJECT-TYPE
Identifies which shelf is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The output module can reside on any chassis (1-5).
1.3.6.1.4.1.601.3.1.1.2.11.2.1.1INTEGER (1..5)not-accessiblecurrent
staLrmMSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.11.2.1.2INTEGER (1..20)not-accessiblecurrent
staLrmMStatus
OBJECT-TYPE
Reports the LRM module state. enable(1), -- module is enabled disable(2), -- module is disabled
1.3.6.1.4.1.601.3.1.1.2.11.2.1.3INTEGER {enable(1), disable(2)}read-onlycurrent
staLrmMRefSrc
OBJECT-TYPE
Reports which clock is selected for generating the output and status. clka(1), -- clock A is selected clkb(2), -- clock B is selected clkc(3), -- clock C is selected clkd(4), -- clock D is selected none(5), -- no clock is selected pllflt(6) -- clock selected, but module's clock PLL is unlocked
1.3.6.1.4.1.601.3.1.1.2.11.2.1.4INTEGER {clka(1), clkb(2), clkc(3), clkd(4), none(5), pllflt(6)}read-onlycurrent
staLrmMCtaId
OBJECT-TYPE
Reports if CTA is installed or not, if installed it reports which type, 2 ports or quad (4) ports. If not installed, none is shown. If id is not recognized, unknown is shown.
1.3.6.1.4.1.601.3.1.1.2.11.2.1.5INTEGER {dual(1), quad(2), none(3), unknown(4)}read-onlycurrent
staLrmPTable
OBJECT-TYPE
A list of DS1 LRM port status information.
1.3.6.1.4.1.601.3.1.1.2.11.3not-accessiblecurrent
staLrmPEntry
OBJECT-TYPE
DS1 LRM module status attributes.
1.3.6.1.4.1.601.3.1.1.2.11.3.1not-accessiblecurrent
staLrmPChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The output module can reside on any chassis (1-5).
1.3.6.1.4.1.601.3.1.1.2.11.3.1.1INTEGER (1..5)not-accessiblecurrent
staLrmPSlot
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.2INTEGER (1..20)not-accessiblecurrent
staLrmPPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.3INTEGER (1..4)not-accessiblecurrent
staLrmPStatus
OBJECT-TYPE
Reports LRM Port status. ok(1), -- port is functioning cut(2), -- port is in cut-through mode disable(3) -- port is disabled
1.3.6.1.4.1.601.3.1.1.2.11.3.1.4INTEGER {ok(1), cut(2), disable(3)}read-onlycurrent
staLrmPFrame
OBJECT-TYPE
Reports LRM Port frame status. d4(1), -- D4 signal esf(2), -- ESF signal none(3) -- indicate Loss Of Frame
1.3.6.1.4.1.601.3.1.1.2.11.3.1.5INTEGER {d4(1), esf(2), none(3)}read-onlycurrent
staLrmPLos
OBJECT-TYPE
Reports LRM Port LOS status.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.6OkValueread-onlycurrent
staLrmPAis
OBJECT-TYPE
Reports LRM Port AIS status.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.7OkValueread-onlycurrent
staLrmPLof
OBJECT-TYPE
Reports LRM Port LOF status.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.8OkValueread-onlycurrent
staLrmPBpv
OBJECT-TYPE
Reports LRM Port BPV status.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.9OkValueread-onlycurrent
staLrmPSlip
OBJECT-TYPE
Reports LRM Port SLIP status. If over the past 24 hours period, the slip count exceeds the threshold, the slip alarm is set.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.10OkValueread-onlycurrent
staLrmPSlips
OBJECT-TYPE
Reports LRM Port slip counts.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.11Counter32read-onlycurrent
staLrmPLosSide2
OBJECT-TYPE
Reports LRM Port LOS on SIDE2 status.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.12OkValueread-onlycurrent
staLrmPBpvTestTime
OBJECT-TYPE
Reports length of time (in seconds) the BPV has been under tested.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.13Counter32read-onlycurrent
staLrmPBpv60SRate
OBJECT-TYPE
Reports BPV Error Rate per second in 60-second window. The format is an ascii text string in float number.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.14DisplayString (SIZE(0..32))read-onlycurrent
staLrmPBpv24HRate
OBJECT-TYPE
Reports BPV Error Rate per second in 86400-second (24 hours) window. The format is an ascii text string in float number.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.15DisplayString (SIZE(0..32))read-onlycurrent
staLrmPBpvErrSecs
OBJECT-TYPE
Reports accumulated BPV Errored Seconds.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.16Counter32read-onlycurrent
staLrmPBpvSevErrSecs
OBJECT-TYPE
Reports accumulated BPV Severely Errored Seconds.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.17Counter32read-onlycurrent
staLrmPBpvSevErrRatio
OBJECT-TYPE
Reports BPV Severely Error Ratio. The format is an ascii text string in float number.
1.3.6.1.4.1.601.3.1.1.2.11.3.1.18DisplayString (SIZE(0..32))read-onlycurrent
statusSineInp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.12
staSineInpTable
OBJECT-TYPE
A list of Sine Input status information.
1.3.6.1.4.1.601.3.1.1.2.12.2not-accessiblecurrent
staSineiEntry
OBJECT-TYPE
Input port status attributes.
1.3.6.1.4.1.601.3.1.1.2.12.2.1not-accessiblecurrent
staSineiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.12.2.1.1INTEGER (1)not-accessiblecurrent
staSineiSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.2INTEGER (1..20)not-accessiblecurrent
staSineiPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.3INTEGER (1..3)not-accessiblecurrent
staSineiStatus
OBJECT-TYPE
Reports input port status. ok(1), -- port is enabled & operating without faults selected(2), -- port is selected as system reference disable(3), -- port is diabled fault(4) -- port is enabled & operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.12.2.1.4INTEGER {ok(1), selected(2), disable(3), fault(4)}read-onlycurrent
staSineiPhaseA
OBJECT-TYPE
Reports input phase value versus clock A. The phaseA is the current 1 second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.5INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staSineiPhaseB
OBJECT-TYPE
Reports input phase value versus clock B. The phaseB is the current 1 second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.6INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staSineiLOS
OBJECT-TYPE
Reports input port has LOS fault.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.7OkValueread-onlycurrent
staSineiMStatus
OBJECT-TYPE
Reports input module status. ok(1), -- module is enabled and operating without faults disable(2), -- module is disabled fault(3) -- module is enabled and operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.12.2.1.8INTEGER {ok(1), disable(2), fault(3)}read-onlycurrent
staSineiPql
OBJECT-TYPE
Reports input port Priority Quality Level (PQL). The PQL is the current stratum level (read or provisioned) being reported by the port. If zero, it is invalid.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.9INTEGER (0 | 1..16)read-onlycurrent
staSineiMtie1A
OBJECT-TYPE
Reports which MTIE limit 1 threshold was exceeded versus clock A. If ok, it means no error for MTIE limit 1 on clock A. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 1 threshold was exceeded versus clock A.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.10INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staSineiMtie2A
OBJECT-TYPE
Reports which MTIE limit 2 threshold was exceeded versus clock A. If ok, it means no error for MTIE limit 2 versus clock A. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 2 threshold was exceeded versus clock A.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.11INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staSineiMtie1B
OBJECT-TYPE
Reports which MTIE limit 1 threshold was exceeded verus clock B. If ok, it means no error for MTIE limit 1 versus clock B. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 1 threshold was exceeded versus clock B.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.12INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staSineiMtie2B
OBJECT-TYPE
Reports which MTIE limit 2 threshold was exceeded versus clock B. If ok, it means no error for MTIE limit 2 versus clock B. If not, one of the 10/ 100/ 1000/ 10000/ 100000 seconds MTIE limit 2 threshold was exceeded versus clock B.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.13INTEGER {ok(1), mtie10(10), mtie100(100), mtie1000(1000), mtie10000(10000), mtie100000(100000)}read-onlycurrent
staSineiFreqA
OBJECT-TYPE
Reports input port frequency threshold exceeded versus clock A.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.14OkValueread-onlycurrent
staSineiFreqB
OBJECT-TYPE
Reports input port frequency threshold exceeded versus clock B.
1.3.6.1.4.1.601.3.1.1.2.12.2.1.15OkValueread-onlycurrent
statusJccInp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.13
staJccInpTable
OBJECT-TYPE
A list of Composite Clock Input status information.
1.3.6.1.4.1.601.3.1.1.2.13.2not-accessiblecurrent
staJcciEntry
OBJECT-TYPE
Input port status attributes.
1.3.6.1.4.1.601.3.1.1.2.13.2.1not-accessiblecurrent
staJcciChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.2.13.2.1.1INTEGER (1)not-accessiblecurrent
staJcciSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.2INTEGER (1..20)not-accessiblecurrent
staJcciPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.3INTEGER (1..3)not-accessiblecurrent
staJcciStatus
OBJECT-TYPE
Reports input port status. ok(1), -- port is enabled & operating without faults selected(2), -- port is selected as system reference disable(3), -- port is diabled fault(4) -- port is enabled & operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.13.2.1.4INTEGER {ok(1), selected(2), disable(3), fault(4)}read-onlycurrent
staJcciPhaseA
OBJECT-TYPE
Reports input phase value versus clock A. The phaseA is the current 1 second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.5INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staJcciPhaseB
OBJECT-TYPE
Reports input phase value versus clock B. The phaseB is the current 1 second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.6INTEGER (-1999999998..1999999998 | 1999999999)read-onlycurrent
staJcciLOS
OBJECT-TYPE
Reports input port has LOS fault.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.7OkValueread-onlycurrent
staJcciBPV
OBJECT-TYPE
Reports input port has BPV fault.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.8OkValueread-onlycurrent
staJcci400Hz
OBJECT-TYPE
Reports input port has 400Hz Sync Signal or not.
1.3.6.1.4.1.601.3.1.1.2.13.2.1.9OnValueread-onlycurrent
staJcciMStatus
OBJECT-TYPE
Reports input module status. ok(1), -- module is enabled and operating without faults disable(2), -- module is disabled fault(3) -- module is enabled and operating with fault(s)
1.3.6.1.4.1.601.3.1.1.2.13.2.1.10INTEGER {ok(1), disable(2), fault(3)}read-onlycurrent
statusLrmE1
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.14
staLrme1MTable
OBJECT-TYPE
A list of E1 LRM port status information.
1.3.6.1.4.1.601.3.1.1.2.14.2not-accessiblecurrent
staLrme1MEntry
OBJECT-TYPE
E1 LRM module status attributes.
1.3.6.1.4.1.601.3.1.1.2.14.2.1not-accessiblecurrent
staLrme1MChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The output module can reside on any chassis (1-5).
1.3.6.1.4.1.601.3.1.1.2.14.2.1.1INTEGER (1..5)not-accessiblecurrent
staLrme1MSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.14.2.1.2INTEGER (1..20)not-accessiblecurrent
staLrme1MStatus
OBJECT-TYPE
Reports the LRM module state. enable(1), -- module is enabled disable(2), -- module is disabled
1.3.6.1.4.1.601.3.1.1.2.14.2.1.3INTEGER {enable(1), disable(2)}read-onlycurrent
staLrme1MRefSrc
OBJECT-TYPE
Reports which clock is selected for generating the output and status. clka(1), -- clock A is selected clkb(2), -- clock B is selected clkc(3), -- clock C is selected clkd(4), -- clock D is selected none(5), -- no clock is selected pllflt(6) -- clock selected, but module's clock PLL is unlocked
1.3.6.1.4.1.601.3.1.1.2.14.2.1.4INTEGER {clka(1), clkb(2), clkc(3), clkd(4), none(5), pllflt(6)}read-onlycurrent
staLrme1MCtaId
OBJECT-TYPE
Reports if CTA is installed or not. If installed it reports which type, 2 ports or quad (4) ports. If not installed, none is shown. If id is not recognized, unknown is shown.
1.3.6.1.4.1.601.3.1.1.2.14.2.1.5INTEGER {dual(1), quad(2), none(3), unknown(4)}read-onlycurrent
staLrme1PTable
OBJECT-TYPE
A list of E1 LRM port status information.
1.3.6.1.4.1.601.3.1.1.2.14.3not-accessiblecurrent
staLrme1PEntry
OBJECT-TYPE
E1 LRM module status attributes.
1.3.6.1.4.1.601.3.1.1.2.14.3.1not-accessiblecurrent
staLrme1PChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The output module can reside on any chassis (1-5).
1.3.6.1.4.1.601.3.1.1.2.14.3.1.1INTEGER (1..5)not-accessiblecurrent
staLrme1PSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.2INTEGER (1..20)not-accessiblecurrent
staLrme1PPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.3INTEGER (1..4)not-accessiblecurrent
staLrme1PStatus
OBJECT-TYPE
Reports LRM Port status. ok(1), -- port is functioning cut(2), -- port is in cut-through mode disable(3) -- port is disabled
1.3.6.1.4.1.601.3.1.1.2.14.3.1.4INTEGER {ok(1), cut(2), disable(3)}read-onlycurrent
staLrme1PFrame
OBJECT-TYPE
Reports LRM Port frame status. cas(1), -- CAS signal ccs(2), -- CCS signal none(3) -- indicate Loss Of Frame
1.3.6.1.4.1.601.3.1.1.2.14.3.1.5OnValueread-onlycurrent
staLrme1PLos
OBJECT-TYPE
Reports LRM Port LOS status.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.6OkValueread-onlycurrent
staLrme1PAis
OBJECT-TYPE
Reports LRM Port AIS status.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.7OkValueread-onlycurrent
staLrme1PLof
OBJECT-TYPE
Reports LRM Port LOF status.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.8OkValueread-onlycurrent
staLrme1PBpv
OBJECT-TYPE
Reports LRM Port BPV status.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.9OkValueread-onlycurrent
staLrme1PSlip
OBJECT-TYPE
Reports LRM Port SLIP status. If over the past 24 hours period, the slip count exceeds the threshold, the slip alarm is set.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.10OkValueread-onlycurrent
staLrme1PSlips
OBJECT-TYPE
Reports LRM Port slip counts.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.11Counter32read-onlycurrent
staLrme1PLosSide2
OBJECT-TYPE
Reports LRM Port LOS on SIDE2 status.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.12OkValueread-onlycurrent
staLrme1PBpv60SRate
OBJECT-TYPE
Reports length of time (in seconds) the BPV has been under tested. The format is an ascii text string in float number.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.13DisplayString (SIZE(0..32))read-onlycurrent
staLrme1PBpv24HRate
OBJECT-TYPE
Reports BPV Error Rate per second in 86400-second (24 hours) window. The format is an ascii text string in float number.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.14DisplayString (SIZE(0..32))read-onlycurrent
staLrme1PBpvErrSecs
OBJECT-TYPE
Reports accumulated BPV Errored Seconds.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.15Counter32read-onlycurrent
staLrme1PBpvSevErrSecs
OBJECT-TYPE
Reports accumulated BPV Severely Errored Seconds.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.16Counter32read-onlycurrent
staLrme1PBpvSevErrRatio
OBJECT-TYPE
Reports BPV Severely Error Ratio. The format is an ascii text string in float number.
1.3.6.1.4.1.601.3.1.1.2.14.3.1.17DisplayString (SIZE(0..32))read-onlycurrent
statusPtNtp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.15
staPtNtpTable
OBJECT-TYPE
A list of PackeTime NTP status information.
1.3.6.1.4.1.601.3.1.1.2.15.1not-accessiblecurrent
staPtNtpEntry
OBJECT-TYPE
PackeTime NTP status attributes.
1.3.6.1.4.1.601.3.1.1.2.15.1.1not-accessiblecurrent
staPtNtpChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.1INTEGER (1..5)not-accessiblecurrent
staPtNtpSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.2INTEGER (1..20)not-accessiblecurrent
staPtNtpStatus
OBJECT-TYPE
The PackeTime NTP module status. ok(1), -- module is enabled and operating without faults disable(3), -- module is disabled fault(4), -- module is enabled and operating with fault(s) reject(5) -- module type between redundant modules do not agree
1.3.6.1.4.1.601.3.1.1.2.15.1.1.3INTEGER {ok(1), disable(3), fault(4), reject(5)}read-onlycurrent
staPtNtpClkSel
OBJECT-TYPE
Reports which clock reference is selected to generate the output reference. clka(1), -- Clock A is selected as the Primary clock clkb(2), -- Clock B is selected as the Primary clock clkc(3), -- Clock C is selected as the Primary clock clkd(4), -- Clock D is selected as the Primary clock none(5) -- no clock is selected
1.3.6.1.4.1.601.3.1.1.2.15.1.1.4INTEGER {clka(1), clkb(2), clkc(3), clkd(4), none(5)}read-onlycurrent
staPtNtpClka
OBJECT-TYPE
Reports that clock A is available.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.5ActiveValueread-onlycurrent
staPtNtpClkb
OBJECT-TYPE
Reports that clock B is available.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.6ActiveValueread-onlycurrent
staPtNtpClkc
OBJECT-TYPE
Reports that clock C is available.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.7ActiveValueread-onlycurrent
staPtNtpClkd
OBJECT-TYPE
Reports that clock D is available.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.8ActiveValueread-onlycurrent
staPtNtpRednt
OBJECT-TYPE
Reports the adjacent slot number if this module is the redundant pair. If this module is not redundant, zero is reported.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.9INTEGER (0..20)read-onlycurrent
staPtNtpModState
OBJECT-TYPE
Reports the current operational mode. active(1), --If the module is in redundant pair and selected, it shall return active. stdby(2), --If the module is in redundant pair but not selected, it shall return stdby (standby). fault(3), --If the module disabled, it will return fault. stdalone(4) --If the module is not redundant pair, it shall return stdalone (standalone).
1.3.6.1.4.1.601.3.1.1.2.15.1.1.10INTEGER {active(1), stdby(2), fault(3), stdalone(4)}read-onlycurrent
staPtNtpPAState
OBJECT-TYPE
Reports the current operational mode. active(1), --If service ports are bonded and selected, it shall return active. stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby). fault(3), --Service port is faulted. stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
1.3.6.1.4.1.601.3.1.1.2.15.1.1.11INTEGER {active(1), stdby(2), fault(3), stdalone(4)}read-onlycurrent
staPtNtpPBState
OBJECT-TYPE
Reports the current operational mode. active(1), --If service ports are bonded and selected, it shall return active. stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby). fault(3), --Service port is faulted. stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
1.3.6.1.4.1.601.3.1.1.2.15.1.1.12INTEGER {active(1), stdby(2), fault(3), stdalone(4)}read-onlycurrent
staPtNtpTod
OBJECT-TYPE
Reports if the NTP Time of Day is valid or invalid.
1.3.6.1.4.1.601.3.1.1.2.15.1.1.13OnValueread-onlycurrent
staPtNtpCommit
OBJECT-TYPE
Reports the Commit command status. 1 = done 2 = in progress
1.3.6.1.4.1.601.3.1.1.2.15.1.1.14INTEGER {done(1), prog(2)}read-onlycurrent
statusPtPtp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.16
staPtPtpTable
OBJECT-TYPE
List of PackeTime PTP status information.
1.3.6.1.4.1.601.3.1.1.2.16.1not-accessiblecurrent
staPtPtpEntry
OBJECT-TYPE
The entries of PackeTime PTP status attributes.
1.3.6.1.4.1.601.3.1.1.2.16.1.1not-accessiblecurrent
staPtPtpChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.1INTEGER (1..5)not-accessiblecurrent
staPtPtpSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.2INTEGER (1..20)not-accessiblecurrent
staPtPtpStatus
OBJECT-TYPE
Reports PackeTime PTP module status. ok(1), -- module is enabled and operating without faults disable(3), -- module is disabled fault(4), -- module is enabled and operating with fault(s) reject(5) -- module type between redundant modules do not agree
1.3.6.1.4.1.601.3.1.1.2.16.1.1.3INTEGER {ok(1), disable(3), fault(4), reject(5)}read-onlycurrent
staPtPtpClkSel
OBJECT-TYPE
Reports which clock reference is selected to generate the output reference. clka(1), -- Clock A is selected as the Primary clock clkb(2), -- Clock B is selected as the Primary clock clkc(3), -- Clock C is selected as the Primary clock clkd(4), -- Clock D is selected as the Primary clock none(5) -- no clock is selected
1.3.6.1.4.1.601.3.1.1.2.16.1.1.4INTEGER {clka(1), clkb(2), clkc(3), clkd(4), none(5)}read-onlycurrent
staPtPtpClka
OBJECT-TYPE
Reports that clock A is available.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.5ActiveValueread-onlycurrent
staPtPtpClkb
OBJECT-TYPE
Reports that clock B is available.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.6ActiveValueread-onlycurrent
staPtPtpClkc
OBJECT-TYPE
Reports that clock C is available.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.7ActiveValueread-onlycurrent
staPtPtpClkd
OBJECT-TYPE
Reports that clock D is available.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.8ActiveValueread-onlycurrent
staPtPtpRednt
OBJECT-TYPE
Reports the adjacent slot number if this module is the redundant pair. If this module is not redundant, zero is reported.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.9INTEGER (0..20)read-onlycurrent
staPtPtpModState
OBJECT-TYPE
Reports the current operational mode. active(1), --If the module is in redundant pair and selected, it shall return active. stdby(2), --If the module is in redundant pair but not selected, it shall return stdby (standby). fault(3), --If the module disabled, it will return fault. stdalone(4) --If the module is not redundant pair, it shall return stdalone (standalone).
1.3.6.1.4.1.601.3.1.1.2.16.1.1.10INTEGER {active(1), stdby(2), fault(3), stdalone(4)}read-onlycurrent
staPtPtpPAState
OBJECT-TYPE
Reports the current operational mode. active(1), --If service ports are bonded and selected, it shall return active. stdby(2), --If service ports are bonded but not selected, it shall return stdby (standby). fault(3), --Service port is faulted. stdalone(4) --If service ports are not bonded , it shall return stdalone (standalone).
1.3.6.1.4.1.601.3.1.1.2.16.1.1.11INTEGER {active(1), stdby(2), fault(3), stdalone(4)}read-onlycurrent
staPtPtpTod
OBJECT-TYPE
Reports if the PTP Time of Day is valid or invalid.
1.3.6.1.4.1.601.3.1.1.2.16.1.1.12OnValueread-onlycurrent
staPtPtpCommit
OBJECT-TYPE
Reports the Commit command status. 1 = done 2 = in progress
1.3.6.1.4.1.601.3.1.1.2.16.1.1.13INTEGER {done(1), prog(2)}read-onlycurrent
ptpDfltDataSetTable
OBJECT-TYPE
List of the PackeTime PTP Management Messages: ptpDefaultDataSet
1.3.6.1.4.1.601.3.1.1.2.16.2not-accessiblecurrent
ptpDfltDataSetEntry
OBJECT-TYPE
The entries of PackeTime PTP Management Messages: ptpDefaultDataSet attributes.
1.3.6.1.4.1.601.3.1.1.2.16.2.1not-accessiblecurrent
ptpDfltDataSetChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.2.1.1INTEGER (1..5)not-accessiblecurrent
ptpDfltDataSetSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.2.1.2INTEGER (1..20)not-accessiblecurrent
ptpDfltDataSetClockId
OBJECT-TYPE
Reports the PTP Clock Identity (64-bit value). The clock id is a hexadecimal format.
1.3.6.1.4.1.601.3.1.1.2.16.2.1.3OCTET STRING (SIZE(8))read-onlycurrent
ptpDfltDataSetClockClass
OBJECT-TYPE
Reports the PTP Master Clock Class
1.3.6.1.4.1.601.3.1.1.2.16.2.1.4INTEGER (0..255)read-onlycurrent
ptpDfltDataSetClockAccuracy
OBJECT-TYPE
Reports the PTP Master Clock Accuracy Following is the Clock Accuracy Table 32 = within 25 ns 33 = within 100 ns 34 = within 250 ns 35 = within 1000 ns 36 = within 2.5 us 37 = within 10 us 38 = within 25 us 39 = within 100 us 40 = within 250 us 41 = within 1 ms 42 = within 2.5 ms 43 = within 10 ms 44 = within 25 ms 45 = within 100 ms 46 = within 250 ms 47 = within 1 sec 48 = within 10 sec 49 = beyond 10 sec 254 = unknown
1.3.6.1.4.1.601.3.1.1.2.16.2.1.5INTEGER {within25ns(32), within100ns(33), within250ns(34), within1000ns(35), within2p5us(36), within10us(37), within25us(38), within100us(39), within250us(40), within1ms(41), within2p5ms(42), within10ms(43), within25ms(44), within100ms(45), within250ms(46), within1sec(47), within10sec(48), beyond10sec(49), unknown(254)}read-onlycurrent
ptpDfltDataSetTimeTraceable
OBJECT-TYPE
Reports the PTP Master Time Traceability 1 = true, time traceable 2 = false, time not traceable
1.3.6.1.4.1.601.3.1.1.2.16.2.1.6TrueValueread-onlycurrent
ptpDfltDataSetFreqTraceable
OBJECT-TYPE
Reports the PTP Master Frequency Traceability 1 = true, frequency traceable 2 = false, frequency not traceable
1.3.6.1.4.1.601.3.1.1.2.16.2.1.7TrueValueread-onlycurrent
ptpDfltDataSetDomainNumber
OBJECT-TYPE
Reports the PTP domain number.
1.3.6.1.4.1.601.3.1.1.2.16.2.1.8INTEGER (0..255)read-onlycurrent
ptpClockDescrTable
OBJECT-TYPE
List of the PackeTime PTP Management Messages: ptpClockDescription.
1.3.6.1.4.1.601.3.1.1.2.16.3not-accessiblecurrent
ptpClockDescrEntry
OBJECT-TYPE
Entries of the PackeTime PTP Management Messages: ptpClockDescription attributes.
1.3.6.1.4.1.601.3.1.1.2.16.3.1not-accessiblecurrent
ptpClockDescrChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.3.1.1INTEGER (1..5)not-accessiblecurrent
ptpClockDescrSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.3.1.2INTEGER (1..20)not-accessiblecurrent
ptpClockDescrClockType
OBJECT-TYPE
Reports the PTP Clock Type The value 0x8000 meant Ordinary Clock
1.3.6.1.4.1.601.3.1.1.2.16.3.1.3INTEGER {ordinary(32768)}read-onlycurrent
ptpClockDescrProtocolAddress
OBJECT-TYPE
Reports the PTP IP Address of PTP port.
1.3.6.1.4.1.601.3.1.1.2.16.3.1.4IpAddressread-onlycurrent
ptpClockDescrManufacturerId
OBJECT-TYPE
Reports the PTP Manufacturer Id. The format is a 3 bytes array. The Manufacturer Id is 00 B0 AE
1.3.6.1.4.1.601.3.1.1.2.16.3.1.5OCTET STRING (SIZE(3))read-onlycurrent
ptpClockDescrProfileId
OBJECT-TYPE
Reports the PTP Profile ID. The format is 6 bytes array. If Telecom-2008, the profile_id is: 00 00 00 00 00 00 If ITU G8265.1, the profile_id is: 00 19 A7 00 01 00
1.3.6.1.4.1.601.3.1.1.2.16.3.1.6OCTET STRING (SIZE(6))read-onlycurrent
ptpTimeMessageTable
OBJECT-TYPE
List of the PackeTime PTP Management Messages: ptpTimeMessage.
1.3.6.1.4.1.601.3.1.1.2.16.4not-accessiblecurrent
ptpTimeMessageEntry
OBJECT-TYPE
The entries of PackeTime PTP Management Messages: ptpTimeMessage attributes
1.3.6.1.4.1.601.3.1.1.2.16.4.1not-accessiblecurrent
ptpTimeMessageChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.4.1.1INTEGER (1..5)not-accessiblecurrent
ptpTimeMessageSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.4.1.2INTEGER (1..20)not-accessiblecurrent
ptpTimeMessageCurrentTimeSec
OBJECT-TYPE
Reports the PTP Current Time of seconds. The current is a 6-byte a hexadecimal format.
1.3.6.1.4.1.601.3.1.1.2.16.4.1.3OCTET STRING (SIZE(6))read-onlycurrent
ptpTimeMessageCurrentTimeNSec
OBJECT-TYPE
Reports the PTP fractional Current Time of nanoseconds
1.3.6.1.4.1.601.3.1.1.2.16.4.1.4Counter32read-onlycurrent
ptpPortDataSetTable
OBJECT-TYPE
List of the PackeTime PTP Management Messages: ptpPortDataSet
1.3.6.1.4.1.601.3.1.1.2.16.5not-accessiblecurrent
ptpPortDataSetEntry
OBJECT-TYPE
The entries of PackeTime PTP Management Messages: ptpPortDataSet attributes
1.3.6.1.4.1.601.3.1.1.2.16.5.1not-accessiblecurrent
ptpPortDataSetChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.5.1.1INTEGER (1..5)not-accessiblecurrent
ptpPortDataSetSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.16.5.1.2INTEGER (1..20)not-accessiblecurrent
ptpPortDataSetClockId
OBJECT-TYPE
Reports the PTP Clock Identity (64-bit value). The port clock id is a hexadecimal format.
1.3.6.1.4.1.601.3.1.1.2.16.5.1.3OCTET STRING (SIZE(8))read-onlycurrent
ptpPortDataSetPortNumber
OBJECT-TYPE
Reports the PTP Port Number
1.3.6.1.4.1.601.3.1.1.2.16.5.1.4INTEGER (0..65535)read-onlycurrent
ptpPortDataSetPortState
OBJECT-TYPE
Reports the PTP Port State Following is the PTP Port State Table 0 = notdefined 1 = initializing 2 = faulty 3 = disabled 4 = listening 5 = premaster, it is a state before becoming a Master 6 = master 7 = passive 8 = uncalibrated 9 = slave
1.3.6.1.4.1.601.3.1.1.2.16.5.1.5INTEGER {notdefined(0), initializing(1), faulty(2), disabled(3), listening(4), premaster(5), master(6), passive(7), uncalibrated(8), slave(9)}read-onlycurrent
statusSynce
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.2.17
staSynceTable
OBJECT-TYPE
List of SyncE status information: port_direction, ethernet_mode, rx_ssm, and tx_ssm
1.3.6.1.4.1.601.3.1.1.2.17.1not-accessiblecurrent
staSynceEntry
OBJECT-TYPE
The entries of SyncE status attributes.
1.3.6.1.4.1.601.3.1.1.2.17.1.1not-accessiblecurrent
staSynceChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.17.1.1.1INTEGER (1..5)not-accessiblecurrent
staSynceSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.2.17.1.1.2INTEGER (1..20)not-accessiblecurrent
staSyncePortDirection
OBJECT-TYPE
Reports SyncE Port Direction to be either Output or Input. The output port is a SyncE master port, and input port is a SyncE slave port.
1.3.6.1.4.1.601.3.1.1.2.17.1.1.3INTEGER {input(1), output(2)}read-onlycurrent
staSynceEthernetMode
OBJECT-TYPE
Reports SyncE operated on Ethernet to be either synchronous or asynchronous. It is synchronous mode, when an optical SFP is detected at an Ethernet port. It is an asynchronous mode, when an electrical SFP is detected at an Ethernet port, or there is no SFP detected.
1.3.6.1.4.1.601.3.1.1.2.17.1.1.4INTEGER {synchronous(1), asynchronous(2)}read-onlycurrent
staSynceRxSsm
OBJECT-TYPE
Reports SyncE the current rx ssm value (0 .. 15). If 255, SyncE does not receive ESMC messages
1.3.6.1.4.1.601.3.1.1.2.17.1.1.5INTEGER (0..15 | 255)read-onlycurrent
staSynceTxSsm
OBJECT-TYPE
Reports SyncE the current tx ssm value (0 .. 15). If 255, SyncE does not transmit ESMC messages
1.3.6.1.4.1.601.3.1.1.2.17.1.1.6INTEGER (0..15 | 255)read-onlycurrent
msetup
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3
setupCom
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.1
setCmId
OBJECT-TYPE
The system identifier, the value is always 'SSU2000'.
1.3.6.1.4.1.601.3.1.1.3.1.1DisplayString (SIZE(7))read-onlycurrent
setCmInfo
OBJECT-TYPE
Symmetricom contact information. This displays the Symmetricom address, phone, and fax numbers.
1.3.6.1.4.1.601.3.1.1.3.1.2DisplayString (SIZE(0..255))read-onlycurrent
setCmVer
OBJECT-TYPE
Reports Communication module's software version
1.3.6.1.4.1.601.3.1.1.3.1.3DisplayString (SIZE(0..100))read-onlycurrent
setCmName
OBJECT-TYPE
Set the user assigned name for the SSU2000. Note: Use caution when changing this, TL1 sessions use the unit name as the target id (tid).
1.3.6.1.4.1.601.3.1.1.3.1.4DisplayString (SIZE(1..20))read-writecurrent
setupClk
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.2
setClkTable
OBJECT-TYPE
A list of clock status and setting information.
1.3.6.1.4.1.601.3.1.1.3.2.1not-accessiblecurrent
setCkEntry
OBJECT-TYPE
Clock status and setting attributes.
1.3.6.1.4.1.601.3.1.1.3.2.1.1not-accessiblecurrent
setCkChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.3.2.1.1.1INTEGER (1..5)not-accessiblecurrent
setCkSlot
OBJECT-TYPE
Identifies which slot is being addressed. This slot number and chassis number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for Clocks are slot 1 and slot 12.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.2INTEGER (1..20)not-accessiblecurrent
setCkWarmup
OBJECT-TYPE
Set the clock warmup time in seconds.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.3INTEGER (900..3600)read-writecurrent
setCkMinTau
OBJECT-TYPE
Set the clock minimum tau. The mintau is the starting time constant value during Locked mode.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.4INTEGER (150..10000)read-writecurrent
setCkMaxTau
OBJECT-TYPE
Set the clock max tau. The maxtau is the final time constant value during Locked mode.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.5INTEGER (150..10000)read-writecurrent
setCkPLLMode
OBJECT-TYPE
Set the clock operating mode to ACQ/ LOCK/ HOLD. Note: When WRITE is to request Clock to change its operating mode, but when READ, it returns status of current operating mode. If current is operating mode is Warmup, it will return as HOLD.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.6INTEGER {acq(2), lock(3), hold(4)}read-writecurrent
setCkTodTimeout
OBJECT-TYPE
Set the TODSRC Timeout. The TOD Traceability Timeout shall allow the system to operate without a valid TOD source for some amount of time before indicating the ToD source is invalid. The timer shall have a user settable range from 60 to 10000 minutes, with a default value of 1440.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.7INTEGER (60..10000)read-writecurrent
setCkFreqTimeout
OBJECT-TYPE
Set the Frequency Timeout. The Frequency Traceability Timeout shall allow the system to operate without a valid input reference for some amount of time before indicating the frequency source is invalid. The timer shall have a user settable range from 60 to 10000 minutes, with a default value of 1440.
1.3.6.1.4.1.601.3.1.1.3.2.1.1.8INTEGER (60..10000)read-writecurrent
setupGps
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.5
setGpsTable
OBJECT-TYPE
A list of GPS status and setting information.
1.3.6.1.4.1.601.3.1.1.3.5.1not-accessiblecurrent
setGpsEntry
OBJECT-TYPE
GPS status and setting attributes.
1.3.6.1.4.1.601.3.1.1.3.5.1.1not-accessiblecurrent
setGpsChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.3.5.1.1.1INTEGER (1)not-accessiblecurrent
setGpsSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.2INTEGER (1..20)not-accessiblecurrent
setGpsEngine
OBJECT-TYPE
Reports the GPS engine manufacturer. na(1), -- not available unknown(2), -- unknown mot(3) -- motorola (or motorola compatible) nvs(4) -- NVS engine (or GLONASS compatible)
1.3.6.1.4.1.601.3.1.1.3.5.1.1.3INTEGER {na(1), unknown(2), mot(3), nvs(4)}read-onlycurrent
setGpsProvPql
OBJECT-TYPE
Set the input port provisioned Priority Quality Level (PQL) value. Note: Valid values are 1 - 9.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.4INTEGER (1..9)read-writecurrent
setGpsPriority
OBJECT-TYPE
Set the input port priority level. The 0 is for monitor-only mode. The 1 is the highest priority. The 10 is the lowest priority.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.5INTEGER (0..10)read-writecurrent
setGpsPdop
OBJECT-TYPE
Set the PDOP mask [3 to 10].
1.3.6.1.4.1.601.3.1.1.3.5.1.1.6INTEGER (3..10)read-writecurrent
setGpsPosel
OBJECT-TYPE
Set the minimum satellite elevation mask for positioning [0 to 90 deg].
1.3.6.1.4.1.601.3.1.1.3.5.1.1.7INTEGER (0..90)read-writecurrent
setGpsTimel
OBJECT-TYPE
Set the minimum satellite elevation mask for timing [0 to 90 deg].
1.3.6.1.4.1.601.3.1.1.3.5.1.1.8INTEGER (0..90)read-writecurrent
setGpsAvg
OBJECT-TYPE
Set satellite position averaging value [20-3600]. Mot GPS: (20 - 3600) of averages for the calculated position fixes NVS GNSS: (20 - 1440) of averaging minutes
1.3.6.1.4.1.601.3.1.1.3.5.1.1.9INTEGER (20..3600)read-writecurrent
setGpsLat
OBJECT-TYPE
Set the antenna latitude of the GPS antenna. The format is +dd:mm:ss.ss or -dd:mm:ss.ss The latitude is +/- 90 deg.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.10TLatAndLonread-writecurrent
setGpsLon
OBJECT-TYPE
Set the antenna longitude of the GPS antenna. The format is +dd:mm:ss.ss or -dd:mm:ss.ss The longitude is +/- 180 deg.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.11TLatAndLonread-writecurrent
setGpsHgt
OBJECT-TYPE
Set the antenna height (meter) of the GPS antenna. The format is +hh.hh or -hh.hh The height is +/- 10000.0 meters.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.12TAntHeightread-writecurrent
setGpsZeroPhase
OBJECT-TYPE
Set phase error to zero for this GPS port. ZEROPHA - set phase A error to zero, ZEROPHB - set phase B error to zero, ZEROPHAB - set phase A and B to zero. Note: This field only is meaningful during the write operation.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.13INTEGER {zeroPhA(1), zeroPhB(2), zeroPhAB(3)}read-writecurrent
setGpsTodsrcPriority
OBJECT-TYPE
Set the TODSRC (Time-Of-Day Source) priority. The priority is the for the specified module as the TOD Source, default is 0, range can be 0 through 8. Value 1 is the highest and 8 is the lowest. If the value is zero, the specified module cannot be TOD Source.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.14INTEGER (0..8)read-writecurrent
setGpsTodsrcCompensation
OBJECT-TYPE
Set the Antenna cable delay compensation {0 – 250} in the case of GPS TOD Source(s) or the delay induced by the cable(s) used to connect expansion shelves where the PackeTime ToD Source(s) is located in relationship to the Main shelf. The time offset shall have a 100nS resolution, thus the Delay value shall be multiplied by 100nS to provide 1PPS compensation. Valid user compensation values range is 0 thru 250 for a total compensation range of 0 to 25000nS (25uS).
1.3.6.1.4.1.601.3.1.1.3.5.1.1.15INTEGER (0..250)read-writecurrent
setGnssConsMode
OBJECT-TYPE
Set constellation mode of GNSS engine. gps(1), -- The constellation mode of gnss engine is gps. glonass(2), -- The constellation mode of gnss engine is glonass gpsGlonass(3), -- The constellation mode of gnss engine is gps+glonass.
1.3.6.1.4.1.601.3.1.1.3.5.1.1.16INTEGER {gps(1), glonass(2), gpsGlonass(3)}read-writecurrent
setAlmThGpsInpTable
OBJECT-TYPE
A list of GPS input alarm attribute setup information.
1.3.6.1.4.1.601.3.1.1.3.5.2not-accessiblecurrent
setMgEntry
OBJECT-TYPE
Input alarm attributes and settings. setMgChassis Identifies which chassis is being addressed. setMgSlot Identifies which slot position is being addressed. setMgMtieStd Set the input port setting of the MTIE limits to predefined values. setMgMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMgMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMgMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMgMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMgMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMgMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMgMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMgMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMgMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMgMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMgMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMgMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMgMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMgMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMgMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMgMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMgMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMgMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMgMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMgMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMgFreqAErrLmt Set the input port frequency error threshold for clock A. setMgFreqAClrLmt Set the input port frequency clear threshold for clock A. setMgFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMgFreqBErrLmt Set the input port frequency error threshold for clock B. setMgFreqBClrLmt Set the input port frequency clear threshold for clock B. setMgFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
1.3.6.1.4.1.601.3.1.1.3.5.2.1not-accessiblecurrent
setMgChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.3.5.2.1.1INTEGER (1)not-accessiblecurrent
setMgSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: In the SSU2000, valid slots for GPS are slot 3 and slot 5.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.2INTEGER (1..20)not-accessiblecurrent
setMgMtieStd
OBJECT-TYPE
Set the input port setting of the MTIE limits to predefined values. prs(1), -- ANSI T1.101 PRS MTIE MASK ds1(2), -- ANSI T1.101 DS1 MTIE MASK g811(3), -- G.811 (PRC) MTIE MASK g823(4) -- G.823 (SSU) MTIE MASK This field is only meaningful for a write operation.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.3INTEGER {prs(1), ds1(2), g811(3), g823(4)}read-writecurrent
setMgMtie10EL1
OBJECT-TYPE
Set the input port MTIE 10 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.4INTEGER (0..60000)read-writecurrent
setMgMtie10EL2
OBJECT-TYPE
Set the input port MTIE 10 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.5INTEGER (0..60000)read-writecurrent
setMgMtie10CL1
OBJECT-TYPE
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.6INTEGER (0..60000)read-writecurrent
setMgMtie10CL2
OBJECT-TYPE
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.7INTEGER (0..60000)read-writecurrent
setMgMtie100EL1
OBJECT-TYPE
Set the input port MTIE 100 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.8INTEGER (0..60000)read-writecurrent
setMgMtie100EL2
OBJECT-TYPE
Set the input port MTIE 100 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.9INTEGER (0..60000)read-writecurrent
setMgMtie100CL1
OBJECT-TYPE
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.10INTEGER (0..60000)read-writecurrent
setMgMtie100CL2
OBJECT-TYPE
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.11INTEGER (0..60000)read-writecurrent
setMgMtie1000EL1
OBJECT-TYPE
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.12INTEGER (0..60000)read-writecurrent
setMgMtie1000EL2
OBJECT-TYPE
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.13INTEGER (0..60000)read-writecurrent
setMgMtie1000CL1
OBJECT-TYPE
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.14INTEGER (0..60000)read-writecurrent
setMgMtie1000CL2
OBJECT-TYPE
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.15INTEGER (0..60000)read-writecurrent
setMgMtie10000EL1
OBJECT-TYPE
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.16INTEGER (0..60000)read-writecurrent
setMgMtie10000EL2
OBJECT-TYPE
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.17INTEGER (0..60000)read-writecurrent
setMgMtie10000CL1
OBJECT-TYPE
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.18INTEGER (0..60000)read-writecurrent
setMgMtie10000CL2
OBJECT-TYPE
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.19INTEGER (0..60000)read-writecurrent
setMgMtie100000EL1
OBJECT-TYPE
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.20INTEGER (0..60000)read-writecurrent
setMgMtie100000EL2
OBJECT-TYPE
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.21INTEGER (0..60000)read-writecurrent
setMgMtie100000CL1
OBJECT-TYPE
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.22INTEGER (0..60000)read-writecurrent
setMgMtie100000CL2
OBJECT-TYPE
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.23INTEGER (0..60000)read-writecurrent
setMgFreqAErrLmt
OBJECT-TYPE
Set the input port frequency error threshold for clock A.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.24INTEGER (0..10000000)read-writecurrent
setMgFreqAClrLmt
OBJECT-TYPE
Set the input port frequency clear threshold for clock A.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.25INTEGER (0..10000000)read-writecurrent
setMgFreqATau
OBJECT-TYPE
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.26INTEGER (10..1000)read-writecurrent
setMgFreqBErrLmt
OBJECT-TYPE
Set the input port frequency error threshold for clock B.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.27INTEGER (0..10000000)read-writecurrent
setMgFreqBClrLmt
OBJECT-TYPE
Set the input port frequency clear threshold for clock B.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.28INTEGER (0..10000000)read-writecurrent
setMgFreqBTau
OBJECT-TYPE
Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
1.3.6.1.4.1.601.3.1.1.3.5.2.1.29INTEGER (10..1000)read-writecurrent
setupDs1E1Inp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.7
setDs1E1InpTable
OBJECT-TYPE
The list of DS1/E1 attribute setup information.
1.3.6.1.4.1.601.3.1.1.3.7.2not-accessiblecurrent
setDiEntry
OBJECT-TYPE
Input status and settings attributes.
1.3.6.1.4.1.601.3.1.1.3.7.2.1not-accessiblecurrent
setDiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The input module can only reside in chassis 1 (main chassis).
1.3.6.1.4.1.601.3.1.1.3.7.2.1.1INTEGER (1)not-accessiblecurrent
setDiSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.2INTEGER (1..20)not-accessiblecurrent
setDiPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.3INTEGER (1..3)not-accessiblecurrent
setDiEnable
OBJECT-TYPE
Set the input port to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.4EnaValueread-writecurrent
setDiFrame
OBJECT-TYPE
Set the input framing type or clock frequency. esf(1), -- T1 ESF d4(2), -- T1 D4 ccs(3), -- E1 CCS cas(4), -- E1 CAS mhz1(5), -- Clock 1MHz khz1544(6), -- Clock 1544kHz khz2048(7), -- Clock 2048kHz mhz5(8), -- Clock 5MHz mhz10(9) -- Clock 10MHz
1.3.6.1.4.1.601.3.1.1.3.7.2.1.5INTEGER {esf(1), d4(2), ccs(3), cas(4), mhz1(5), khz1544(6), khz2048(7), mhz5(8), mhz10(9)}read-writecurrent
setDiZS
OBJECT-TYPE
Set Zero Supression (ZS) on the input port to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.6OnValueread-writecurrent
setDiCRC
OBJECT-TYPE
Set CRC verificaiton on the input port to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.7OnValueread-writecurrent
setDiSSM
OBJECT-TYPE
Set Sync Status Messaging (SSM) on the input port to enabled or disabled..
1.3.6.1.4.1.601.3.1.1.3.7.2.1.8OnValueread-writecurrent
setDiProvPql
OBJECT-TYPE
Set the input port provisioned Priority Quality Level (PQL). Note: Valid values are 1 - 9.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.9INTEGER (1..9)read-writecurrent
setDiPriority
OBJECT-TYPE
Set the input port priority level. '0' = monitoring, '1' = highest priority, '10' = lowest priority.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.10INTEGER (0..10)read-writecurrent
setDiGain
OBJECT-TYPE
Set the input port gain setting to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.11OnValueread-writecurrent
setDiCSFlt
OBJECT-TYPE
Set input Port 1 for external Cesium (CS) fault alarm logic level. off(1), -- function is disabled low(2), -- function is enabled, will trigger on low (0V) level high(3), -- function is enabled, will trigger on high (+5v) level na(4) -- not applicable Note: only available for port one.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.12INTEGER {off(1), low(2), high(3), na(4)}read-writecurrent
setDiE1SsmBit
OBJECT-TYPE
Set the input port E1 Sync Status Message (SSM) bit position. This command is only meaningful for the E1 input module. For DS1, this value is always 4, and has no meaning (i.e. not used).
1.3.6.1.4.1.601.3.1.1.3.7.2.1.13INTEGER (4..8)read-writecurrent
setDiZeroPhase
OBJECT-TYPE
Set the phase error to zero for this input port. ZEROPHA - set phase A error to zero, ZEROPHB - set phase B error to zero, ZEROPHAB - set phase A and B to zero. Note: This field only is meaningful during the write operation.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.14INTEGER {zeroPhA(1), zeroPhB(2), zeroPhAB(3)}read-writecurrent
setDiMtieCalc
OBJECT-TYPE
Reports MTIE calculator (40Hz or 1Hz) being used The number represents the input port setting for MTIE Calculator measurement. - 40Hz - Selects the 40Hz MTIE values to set/clear MTIE alarms - 1Hz - Selects the 1Hz MTIE values to set/clear MTIE alarms Note: only available for port one.
1.3.6.1.4.1.601.3.1.1.3.7.2.1.15INTEGER {hz40(1), hz1(2)}read-writecurrent
setAlmThDs1E1InpTable
OBJECT-TYPE
A list of DS1/E1 input alarm attributes and settings information.
1.3.6.1.4.1.601.3.1.1.3.7.4not-accessiblecurrent
setMiEntry
OBJECT-TYPE
Input alarm attributes and settings. setMiChassis Identifies which chassis is being addressed. setMiSlot Identifies which slot position is being addressed. setMiPort Identifies which port position is being addressed. setMiMtieStd Set the input port setting of the MTIE limits to predefined values. setMiMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMiMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMiMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMiMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMiMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMiMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMiMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMiMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMiMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMiMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMiMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMiMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMiMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMiMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMiMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMiMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMiMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMiMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMiMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMiMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMiFreqAErrLmt Set the input port frequency error threshold for clock A. setMiFreqAClrLmt Set the input port frequency clear threshold for clock A. setMiFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMiFreqBErrLmt Set the input port frequency error threshold for clock B. setMiFreqBClrLmt Set the input port frequency clear threshold for clock B. setMiFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B. setMiLOSErrCnt Set the input port error count threshold for LOS signal faults. setMiLOSClrCnt Set the input port clear count threshold for LOS signal faults. setMiAISErrCnt Set the input port error count threshold for AIS signal faults. setMiAISClrCnt Set the input port clear count threshold for AIS signal faults. setMiOOFErrCnt Set the input port error count threshold for OOF signal faults. setMiOOFClrCnt Set the input port clear count threshold for OOF signal faults. setMiBPVErrCnt Set the input port error count threshold for BPV signal faults. setMiBPVClrCnt Set the input port clear count threshold for BPV signal faults. setMiCRCErrCnt Set the input port error count threshold for CRC signal faults. setMiCRCClrCnt Set the input port clear count threshold for CRC signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1not-accessiblecurrent
setMiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.3.7.4.1.1INTEGER (1)not-accessiblecurrent
setMiSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.2INTEGER (1..20)not-accessiblecurrent
setMiPort
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.3INTEGER (1..3)not-accessiblecurrent
setMiMtieStd
OBJECT-TYPE
Set the input port setting of the MTIE limits to predefined values. prs(1), -- ANSI T1.101 PRS MTIE MASK ds1(2), -- ANSI T1.101 DS1 MTIE MASK g811(3), -- G.811 (PRC) MTIE MASK g823(4) -- G.823 (SSU) MTIE MASK This field is only meaningful for a write operation.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.4INTEGER {prs(1), ds1(2), g811(3), g823(4)}read-writecurrent
setMiMtie10EL1
OBJECT-TYPE
Set the input port MTIE 10 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.5INTEGER (0..60000)read-writecurrent
setMiMtie10EL2
OBJECT-TYPE
Set the input port MTIE 10 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.6INTEGER (0..60000)read-writecurrent
setMiMtie10CL1
OBJECT-TYPE
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.7INTEGER (0..60000)read-writecurrent
setMiMtie10CL2
OBJECT-TYPE
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.8INTEGER (0..60000)read-writecurrent
setMiMtie100EL1
OBJECT-TYPE
Set the input port MTIE 100 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.9INTEGER (0..60000)read-writecurrent
setMiMtie100EL2
OBJECT-TYPE
Set the input port MTIE 100 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.10INTEGER (0..60000)read-writecurrent
setMiMtie100CL1
OBJECT-TYPE
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.11INTEGER (0..60000)read-writecurrent
setMiMtie100CL2
OBJECT-TYPE
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.12INTEGER (0..60000)read-writecurrent
setMiMtie1000EL1
OBJECT-TYPE
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.13INTEGER (0..60000)read-writecurrent
setMiMtie1000EL2
OBJECT-TYPE
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.14INTEGER (0..60000)read-writecurrent
setMiMtie1000CL1
OBJECT-TYPE
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.15INTEGER (0..60000)read-writecurrent
setMiMtie1000CL2
OBJECT-TYPE
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.16INTEGER (0..60000)read-writecurrent
setMiMtie10000EL1
OBJECT-TYPE
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.17INTEGER (0..60000)read-writecurrent
setMiMtie10000EL2
OBJECT-TYPE
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.18INTEGER (0..60000)read-writecurrent
setMiMtie10000CL1
OBJECT-TYPE
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.19INTEGER (0..60000)read-writecurrent
setMiMtie10000CL2
OBJECT-TYPE
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.20INTEGER (0..60000)read-writecurrent
setMiMtie100000EL1
OBJECT-TYPE
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.21INTEGER (0..60000)read-writecurrent
setMiMtie100000EL2
OBJECT-TYPE
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.22INTEGER (0..60000)read-writecurrent
setMiMtie100000CL1
OBJECT-TYPE
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.23INTEGER (0..60000)read-writecurrent
setMiMtie100000CL2
OBJECT-TYPE
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.24INTEGER (0..60000)read-writecurrent
setMiFreqAErrLmt
OBJECT-TYPE
Set the input port frequency error threshold for clock A.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.25INTEGER (0..10000000)read-writecurrent
setMiFreqAClrLmt
OBJECT-TYPE
Set the input port frequency clear threshold for clock A.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.26INTEGER (0..10000000)read-writecurrent
setMiFreqATau
OBJECT-TYPE
Set the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock A.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.27INTEGER (10..1000)read-writecurrent
setMiFreqBErrLmt
OBJECT-TYPE
Set the input port frequency error threshold for clock B.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.28INTEGER (0..10000000)read-writecurrent
setMiFreqBClrLmt
OBJECT-TYPE
Set the input port frequency clear threshold for clock B.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.29INTEGER (0..10000000)read-writecurrent
setMiFreqBTau
OBJECT-TYPE
Set the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock B.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.30INTEGER (10..1000)read-writecurrent
setMiLOSErrCnt
OBJECT-TYPE
Set the input port error count threshold for LOS signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.31INTEGER (1..100)read-writecurrent
setMiLOSClrCnt
OBJECT-TYPE
Set the input port clear count threshold for LOS signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.32INTEGER (1..100)read-writecurrent
setMiAISErrCnt
OBJECT-TYPE
Set the input port error count threshold for AIS signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.33INTEGER (1..100)read-writecurrent
setMiAISClrCnt
OBJECT-TYPE
Set the input port clear count threshold for AIS signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.34INTEGER (1..100)read-writecurrent
setMiOOFErrCnt
OBJECT-TYPE
Set the input port error count threshold for OOF signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.35INTEGER (1..10000)read-writecurrent
setMiOOFClrCnt
OBJECT-TYPE
Set the input port clear count threshold for OOF signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.36INTEGER (1..10000)read-writecurrent
setMiBPVErrCnt
OBJECT-TYPE
Set the input port error count threshold for BPV signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.37INTEGER (1..10000)read-writecurrent
setMiBPVClrCnt
OBJECT-TYPE
Set the input port clear count threshold for BPV signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.38INTEGER (1..10000)read-writecurrent
setMiCRCErrCnt
OBJECT-TYPE
Set the input port error count hreshold for CRC signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.39INTEGER (1..10000)read-writecurrent
setMiCRCClrCnt
OBJECT-TYPE
Set the input port clear count threshold for CRC signal faults.
1.3.6.1.4.1.601.3.1.1.3.7.4.1.40INTEGER (1..10000)read-writecurrent
setupCcInp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.8
setCcInpTable
OBJECT-TYPE
The list of CC Input attribute setup information.
1.3.6.1.4.1.601.3.1.1.3.8.2not-accessiblecurrent
setCiEntry
OBJECT-TYPE
Input status and settings attributes.
1.3.6.1.4.1.601.3.1.1.3.8.2.1not-accessiblecurrent
setCiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The input module can only reside in chassis 1 (main chassis).
1.3.6.1.4.1.601.3.1.1.3.8.2.1.1INTEGER (1)not-accessiblecurrent
setCiSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.8.2.1.2INTEGER (1..20)not-accessiblecurrent
setCiPort
OBJECT-TYPE
Identifies which port position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.8.2.1.3INTEGER (1..3)not-accessiblecurrent
setCiEnable
OBJECT-TYPE
Set the input port to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.8.2.1.4EnaValueread-writecurrent
setCiProvPql
OBJECT-TYPE
Set the input port provisioned Priority Quality Level (PQL). Note: Valid values are 1 - 9.
1.3.6.1.4.1.601.3.1.1.3.8.2.1.7INTEGER (1..9)read-writecurrent
setCiPriority
OBJECT-TYPE
Set the input port priority level. '0' = monitoring, '1' = highest priority, '10' = lowest priority.
1.3.6.1.4.1.601.3.1.1.3.8.2.1.8INTEGER (0..10)read-writecurrent
setCiZeroPhase
OBJECT-TYPE
Set the phase error to zero for this input port. ZEROPHA - set phase A error to zero, ZEROPHB - set phase B error to zero, ZEROPHAB - set phase A and B to zero. Note: This field only is meaningful during the write operation.
1.3.6.1.4.1.601.3.1.1.3.8.2.1.9INTEGER {zeroPhA(1), zeroPhB(2), zeroPhAB(3)}read-writecurrent
setAlmThCcInpTable
OBJECT-TYPE
A list of CC input alarm attributes and settings information.
1.3.6.1.4.1.601.3.1.1.3.8.4not-accessiblecurrent
setCimEntry
OBJECT-TYPE
Input alarm attributes and settings. setMiChassis Identifies which chassis is being addressed. setMiSlot Identifies which slot position is being addressed. setMiPort Identifies which port position is being addressed. setCimLOSErrCnt Set the input port error count threshold for LOS signal faults. setCimLOSClrCnt Set the input port clear count threshold for LOS signal faults. setCimBPVErrCnt Set the input port error count threshold for BPV signal faults. setCimBPVClrCnt Set the input port clear count threshold for BPV signal faults.
1.3.6.1.4.1.601.3.1.1.3.8.4.1not-accessiblecurrent
setCimChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.3.8.4.1.1INTEGER (1)not-accessiblecurrent
setCimSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.8.4.1.2INTEGER (1..20)not-accessiblecurrent
setCimPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.8.4.1.3INTEGER (1..3)not-accessiblecurrent
setCimLOSErrCnt
OBJECT-TYPE
Set the input port error count threshold for LOS signal faults.
1.3.6.1.4.1.601.3.1.1.3.8.4.1.4INTEGER (1..100)read-writecurrent
setCimLOSClrCnt
OBJECT-TYPE
Set the input port clear count threshold for LOS signal faults.
1.3.6.1.4.1.601.3.1.1.3.8.4.1.5INTEGER (1..100)read-writecurrent
setCimBPVErrCnt
OBJECT-TYPE
Set the input port error count threshold for BPV signal faults.
1.3.6.1.4.1.601.3.1.1.3.8.4.1.10INTEGER (1..10000)read-writecurrent
setCimBPVClrCnt
OBJECT-TYPE
Set the input port clear count threshold for BPV signal faults.
1.3.6.1.4.1.601.3.1.1.3.8.4.1.11INTEGER (1..10000)read-writecurrent
setupDs1Out
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.10
setDsTable
OBJECT-TYPE
A list of DS1 output module status and settings.
1.3.6.1.4.1.601.3.1.1.3.10.2not-accessiblecurrent
setDsEntry
OBJECT-TYPE
Set DS1 output attributes.
1.3.6.1.4.1.601.3.1.1.3.10.2.1not-accessiblecurrent
setDsChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.1INTEGER (1..5)not-accessiblecurrent
setDsSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.2INTEGER (1..20)not-accessiblecurrent
setDsFrame
OBJECT-TYPE
Set the output signal framing mode. The T1 framing mode is ESF or D4.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.3INTEGER {esf(1), d4(2)}read-writecurrent
setDsBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.4OnValueread-writecurrent
setDsZs
OBJECT-TYPE
Set the Zero Suppression to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.5OnValueread-writecurrent
setDsEnable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setDsLength
OBJECT-TYPE
Set the cable length compensation for the output port. Cable length definitions: 1 = 133 ft 2 = 266 ft 3 = 399 ft 4 = 533 ft 5 = 655 ft Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.10.2.1.7OCTET STRING (SIZE(20))read-writecurrent
setupE1Out
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.11
setE1Table
OBJECT-TYPE
A list of DS1 output module status and settings.
1.3.6.1.4.1.601.3.1.1.3.11.2not-accessiblecurrent
setE1Entry
OBJECT-TYPE
Set DS1 output attributes.
1.3.6.1.4.1.601.3.1.1.3.11.2.1not-accessiblecurrent
setE1Chassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.1INTEGER (1..5)not-accessiblecurrent
setE1Slot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.2INTEGER (1..20)not-accessiblecurrent
setE1Frame
OBJECT-TYPE
Set the output signal framing mode. 1=ccs 2=cas
1.3.6.1.4.1.601.3.1.1.3.11.2.1.3INTEGER {ccs(1), cas(2)}read-writecurrent
setE1Bypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.4OnValueread-writecurrent
setE1Zs
OBJECT-TYPE
Set the Zero Suppression to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.5OnValueread-writecurrent
setE1Crc
OBJECT-TYPE
Set the CRC error checking to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.6OnValueread-writecurrent
setE1SsmBit
OBJECT-TYPE
Set output module E1 SSM bit position. bit=4 - 8 Note: This field is only valid for E1 output module.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.7INTEGER (4..8)read-writecurrent
setE1Enable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.11.2.1.8OCTET STRING (SIZE(20))read-writecurrent
setup2048Out
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.12
setCoTable
OBJECT-TYPE
A list of 2048kHz output module status and settings.
1.3.6.1.4.1.601.3.1.1.3.12.2not-accessiblecurrent
setCoEntry
OBJECT-TYPE
Set 2048kHz output attributes.
1.3.6.1.4.1.601.3.1.1.3.12.2.1not-accessiblecurrent
setCoChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.12.2.1.1INTEGER (1..5)not-accessiblecurrent
setCoSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.12.2.1.2INTEGER (1..20)not-accessiblecurrent
setCoBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.12.2.1.3OnValueread-writecurrent
setCoFltMode
OBJECT-TYPE
Set the signal fault mode for low level output signals off(1), -- will turn off the output and requires user issued command to turn it back on on(2), -- will not turn off when fault detected auto(3) -- will turn off the output and automatically turn back on when fault clears
1.3.6.1.4.1.601.3.1.1.3.12.2.1.4INTEGER {off(1), on(2), auto(3)}read-writecurrent
setCoEnable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.12.2.1.5OCTET STRING (SIZE(20))read-writecurrent
setCoSquelch
OBJECT-TYPE
Set PQL threshold to turn port off. If the system PQL is below the PWL threshold the port is turned off (i.e. squelched). Note: Byte 1 = port 1, byte 20 = port 20. The PQL value of each byte defined as follows: 0 = disabled 1-16 = Provision PQL value
1.3.6.1.4.1.601.3.1.1.3.12.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setupCCOut
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.13
setCcTable
OBJECT-TYPE
A list of Composite Clock (CC) output module status and settings.
1.3.6.1.4.1.601.3.1.1.3.13.2not-accessiblecurrent
setCcEntry
OBJECT-TYPE
Set CC output attributes.
1.3.6.1.4.1.601.3.1.1.3.13.2.1not-accessiblecurrent
setCcChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each CC Output entry.
1.3.6.1.4.1.601.3.1.1.3.13.2.1.1INTEGER (1..5)not-accessiblecurrent
setCcSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each CC Output entry.
1.3.6.1.4.1.601.3.1.1.3.13.2.1.2INTEGER (1..20)not-accessiblecurrent
setCcBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.13.2.1.3OnValueread-writecurrent
setCcEnable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.13.2.1.4OCTET STRING (SIZE(20))read-writecurrent
setCcDuty
OBJECT-TYPE
Set the output duty cycle for the output ports. 1 = 63/37 duty cycle. 2 = 50/50 duty cycle. Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.13.2.1.5OCTET STRING (SIZE(20))read-writecurrent
setCcComp
OBJECT-TYPE
Set the output phase (cable) compensation for the output ports. The equivalent cable length: 1 = 2200 ft, 2 = 1925 ft, 3 = 1650 ft, 4 = 1375 ft, 5 = 1100 ft, 6 = 825 ft, 7 = 550 ft, 8 = 275 ft. Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.13.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setup422Out
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.14
set422oTable
OBJECT-TYPE
A list of 2048kHz output module status and settings.
1.3.6.1.4.1.601.3.1.1.3.14.2not-accessiblecurrent
set422oEntry
OBJECT-TYPE
Set 422 output attributes.
1.3.6.1.4.1.601.3.1.1.3.14.2.1not-accessiblecurrent
set422oChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.14.2.1.1INTEGER (1..5)not-accessiblecurrent
set422oSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.14.2.1.2INTEGER (1..20)not-accessiblecurrent
set422oBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.14.2.1.3OnValueread-writecurrent
set422oFltMode
OBJECT-TYPE
Set the signal fault mode for low level output signals off(1), -- will turn off the output and requires user issued command to turn it back on on(2), -- will not turn off when fault detected auto(3) -- will turn off the output and automatically turn back on when fault clears
1.3.6.1.4.1.601.3.1.1.3.14.2.1.4INTEGER {off(1), on(2), auto(3)}read-writecurrent
set422oEnable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.14.2.1.5OCTET STRING (SIZE(20))read-writecurrent
set422oFrequency
OBJECT-TYPE
Set frequency for each port on an RS422 output module. word 1 = port 1, word 10 = port 10. The frequency value of each port defined as follows: 0 = 4kHz, 1-512 = 8kHz to 4096kHz with 8kHz per step. Note: each port use 2-bytes to set frequency. User can only set frequency on port 1 thru port 10. The port 1 and 11, port 2 and 12,.., port 10 and 20 have the same frequency setting. For example, when you set port1, you are set the same frequency for port 11.
1.3.6.1.4.1.601.3.1.1.3.14.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setupE12048Out
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.15
setE12048oTable
OBJECT-TYPE
A list of E1/2048 output module status and settings.
1.3.6.1.4.1.601.3.1.1.3.15.2not-accessiblecurrent
setE12048oEntry
OBJECT-TYPE
Set E1/2048 output attributes.
1.3.6.1.4.1.601.3.1.1.3.15.2.1not-accessiblecurrent
setE12048oChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.1INTEGER (1..5)not-accessiblecurrent
setE12048oSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.2INTEGER (1..20)not-accessiblecurrent
setE12048oBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.3OnValueread-writecurrent
setE12048oZs
OBJECT-TYPE
Set the Zero Suppression to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.4OnValueread-writecurrent
setE12048oSignal
OBJECT-TYPE
Set the output ports to E1 or 2048kHz. 1 = E1 2 = 2048 kHz Note: byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.5OCTET STRING (SIZE(20))read-writecurrent
setE12048oEnable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setE12048oSquelch
OBJECT-TYPE
Set the PQL squelch threshold for each port. If a PQL threshold is below the system PQL, this port is turned off (i.e. squelched). 0 = disabled 1-16 = Provision PQL value Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.7OCTET STRING (SIZE(20))read-writecurrent
setE12048oFrame
OBJECT-TYPE
Set E1 output signal framer mode. 1 = CCS 2 = CAS
1.3.6.1.4.1.601.3.1.1.3.15.2.1.8INTEGER {ccs(1), cas(2)}read-writecurrent
setE12048oCrc
OBJECT-TYPE
Set E1 output CRC error checking to on or off.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.9OnValueread-writecurrent
setE12048oSsm
OBJECT-TYPE
Set E1 output SSM generation to on or off.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.10OnValueread-writecurrent
setE12048oSsmBit
OBJECT-TYPE
Set E1 output SSM bit position. bit position = 4 - 8 Note: This field is only valid for E1 output module.
1.3.6.1.4.1.601.3.1.1.3.15.2.1.11INTEGER (4..8)read-writecurrent
setupLrm
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.16
setLrmPTable
OBJECT-TYPE
A list of DS1 LRM ports status and settings.
1.3.6.1.4.1.601.3.1.1.3.16.2not-accessiblecurrent
setLrmPEntry
OBJECT-TYPE
Set DS1 LRM attributes.
1.3.6.1.4.1.601.3.1.1.3.16.2.1not-accessiblecurrent
setLrmPChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.1INTEGER (1..5)not-accessiblecurrent
setLrmPSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.2INTEGER (1..20)not-accessiblecurrent
setLrmPPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.3INTEGER (1..4)not-accessiblecurrent
setLrmPEnable
OBJECT-TYPE
Set the LRM ports to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.4OnValueread-writecurrent
setLrmPLbo
OBJECT-TYPE
Set the Line Build-Out for the LRM port. 1=lbo133ft 2=lbo266ft 3=lbo399ft 4=lbo533ft 5=lbo655ft
1.3.6.1.4.1.601.3.1.1.3.16.2.1.5INTEGER {lbo133ft(1), lbo266ft(2), lbo399ft(3), lbo533ft(4), lbo655ft(5)}read-writecurrent
setLrmPSlip
OBJECT-TYPE
Set the slip error threshold in 24 hours period and the value zero shall clear the slip accumulated errors.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.6INTEGER (0..255)read-writecurrent
setLrmPBpv
OBJECT-TYPE
Clear the accumulated BPV errors clr(1), -- clear the accumulated BPV errors nop(2) -- no operation Note: This field only has meaning for a write operation.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.7INTEGER {clr(1), nop(2)}read-writecurrent
setLrmPFlt
OBJECT-TYPE
Set the Side 1 fault strategy
1.3.6.1.4.1.601.3.1.1.3.16.2.1.8INTEGER {squelch(1), ais(2)}read-writecurrent
setLrmPCid
OBJECT-TYPE
Set the circuit id for LRM port The circuit id is an 0-43 character string with all ascii printable characters.
1.3.6.1.4.1.601.3.1.1.3.16.2.1.9DisplayString (SIZE(0..43))read-writecurrent
setupSineOut
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.17
setSineoTable
OBJECT-TYPE
A list of Sine output status and settings.
1.3.6.1.4.1.601.3.1.1.3.17.2not-accessiblecurrent
setSineoEntry
OBJECT-TYPE
Set E1 LRM attributes.
1.3.6.1.4.1.601.3.1.1.3.17.2.1not-accessiblecurrent
setSineoChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.17.2.1.1INTEGER (1..5)not-accessiblecurrent
setSineoSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.17.2.1.2INTEGER (1..20)not-accessiblecurrent
setSineoBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.17.2.1.3OnValueread-writecurrent
setSineoFrequency
OBJECT-TYPE
Set the output frequency 1.544 or 6.312 MHz.
1.3.6.1.4.1.601.3.1.1.3.17.2.1.4INTEGER (1544 | 6312)read-writecurrent
setSineoEnable
OBJECT-TYPE
Set the output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.17.2.1.5OCTET STRING (SIZE(20))read-writecurrent
setSineoSquelch
OBJECT-TYPE
Set PQL threshold to turn port off. If the system PQL is below the PWL threshold the port is turned off (i.e. squelched). Note: Byte 1 = port 1, byte 20 = port 20. The PQL value of each byte defined as follows: 0 = disabled 1-16 = Provision PQL value
1.3.6.1.4.1.601.3.1.1.3.17.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setupSineInp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.18
setSineInpTable
OBJECT-TYPE
The list of Sine Input attribute setup information.
1.3.6.1.4.1.601.3.1.1.3.18.2not-accessiblecurrent
setSineiEntry
OBJECT-TYPE
Input status and settings attributes.
1.3.6.1.4.1.601.3.1.1.3.18.2.1not-accessiblecurrent
setSineiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The input module can only reside in chassis 1 (main chassis).
1.3.6.1.4.1.601.3.1.1.3.18.2.1.1INTEGER (1)not-accessiblecurrent
setSineiSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.2INTEGER (1..20)not-accessiblecurrent
setSineiPort
OBJECT-TYPE
Identifies which port position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.3INTEGER (1..3)not-accessiblecurrent
setSineiEnable
OBJECT-TYPE
Set the input port to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.4EnaValueread-writecurrent
setSineiFrequency
OBJECT-TYPE
Set input signal frequency. The frequency can be set: 1.544MHZ/ 6.312MHz.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.5INTEGER (1544 | 6312)read-writecurrent
setSineiProvPql
OBJECT-TYPE
Set the input port provisioned Priority Quality Level (PQL). Note: Valid values are 1 - 9.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.6INTEGER (1..9)read-writecurrent
setSineiPriority
OBJECT-TYPE
Set the input port priority level. '0' = monitoring, '1' = highest priority, '10' = lowest priority.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.7INTEGER (0..10)read-writecurrent
setSineiCSFlt
OBJECT-TYPE
Set input Port 1 for external Cesium (CS) fault alarm logic level. off(1), -- function is disabled low(2), -- function is enabled, will trigger on low (0V) level high(3), -- function is enabled, will trigger on high (+5v) level na(4) -- not applicable Note: only available for port one.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.8INTEGER {off(1), low(2), high(3), na(4)}read-writecurrent
setSineiZeroPhase
OBJECT-TYPE
Set the phase error to zero for this input port. ZEROPHA - set phase A error to zero, ZEROPHB - set phase B error to zero, ZEROPHAB - set phase A and B to zero. Note: This field only is meaningful during the write operation.
1.3.6.1.4.1.601.3.1.1.3.18.2.1.9INTEGER {zeroPhA(1), zeroPhB(2), zeroPhAB(3)}read-writecurrent
setAlmThSineInpTable
OBJECT-TYPE
A list of Sine input alarm attributes and settings information.
1.3.6.1.4.1.601.3.1.1.3.18.4not-accessiblecurrent
setMsiEntry
OBJECT-TYPE
Input alarm attributes and settings. setMsiChassis Identifies which chassis is being addressed. setMsiSlot Identifies which slot position is being addressed. setMsiPort Identifies which port position is being addressed. setMsiMtieStd Set the input port setting of the MTIE limits to predefined values. setMsiMtie10EL1 Set the input port MTIE 10 seconds error threshold for the first limit setting. setMsiMtie10EL2 Set the input port MTIE 10 seconds error threshold for the second limit setting. setMsiMtie10CL1 Set the input port MTIE 10 seconds clear threshold for the first limit setting. setMsiMtie10CL2 Set the input port MTIE 10 seconds clear threshold for the second limit setting. setMsiMtie100EL1 Set the input port MTIE 100 seconds error threshold for the first limit setting. setMsiMtie100EL2 Set the input port MTIE 100 seconds error threshold for the second limit setting. setMsiMtie100CL1 Set the input port MTIE 100 seconds clear threshold for the first limit setting. setMsiMtie100CL2 Set the input port MTIE 100 seconds clear threshold for the second limit setting. setMsiMtie1000EL1 Set the input port MTIE 1000 seconds error threshold for the first limit setting. setMsiMtie1000EL2 Set the input port MTIE 1000 seconds error threshold for the second limit setting. setMsiMtie1000CL1 Set the input port MTIE 1000 seconds clear threshold for the first limit setting. setMsiMtie1000CL2 Set the input port MTIE 1000 seconds clear threshold for the second limit setting. setMsiMtie10000EL1 Set the input port MTIE 10000 seconds error threshold for the first limit setting. setMsiMtie10000EL2 Set the input port MTIE 10000 seconds error threshold for the second limit setting. setMsiMtie10000CL1 Set the input port MTIE 10000 seconds clear threshold for the first limit setting. setMsiMtie10000CL2 Set the input port MTIE 10000 seconds clear threshold for the second limit setting. setMsiMtie100000EL1 Set the input port MTIE 100000 seconds error threshold for the first limit setting. setMsiMtie100000EL2 Set the input port MTIE 100000 seconds error threshold for the second limit setting. setMsiMtie100000CL1 Set the input port MTIE 100000 seconds clear threshold for the first limit setting. setMsiMtie100000CL2 Set the input port MTIE 100000 seconds clear threshold for the second limit setting. setMsiFreqAErrLmt Set the input port frequency error threshold for clock A. setMsiFreqAClrLmt Set the input port frequency clear threshold for clock A. setMsiFreqATau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock A. setMsiFreqBErrLmt Set the input port frequency error threshold for clock B. setMsiFreqBClrLmt Set the input port frequency clear threshold for clock B. setMsiFreqBTau Set the Time constant (tau), in seconds, used for the calculation of the Average Frequency versus clock B.
1.3.6.1.4.1.601.3.1.1.3.18.4.1not-accessiblecurrent
setMsiChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry. Note: In the SSU2000, this number is always one. (i.e. in the main chassis)
1.3.6.1.4.1.601.3.1.1.3.18.4.1.1INTEGER (1)not-accessiblecurrent
setMsiSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.2INTEGER (1..20)not-accessiblecurrent
setMsiPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot number, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.3INTEGER (1..3)not-accessiblecurrent
setMsiMtieStd
OBJECT-TYPE
Set the input port setting of the MTIE limits to predefined values. prs(1), -- ANSI T1.101 PRS MTIE MASK ds1(2), -- ANSI T1.101 DS1 MTIE MASK g811(3), -- G.811 (PRC) MTIE MASK g823(4) -- G.823 (SSU) MTIE MASK This field is only meaningful for a write operation.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.4INTEGER {prs(1), ds1(2), g811(3), g823(4)}read-writecurrent
setMsiMtie10EL1
OBJECT-TYPE
Set the input port MTIE 10 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.5INTEGER (0..60000)read-writecurrent
setMsiMtie10EL2
OBJECT-TYPE
Set the input port MTIE 10 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.6INTEGER (0..60000)read-writecurrent
setMsiMtie10CL1
OBJECT-TYPE
Set the input port MTIE 10 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.7INTEGER (0..60000)read-writecurrent
setMsiMtie10CL2
OBJECT-TYPE
Set the input port MTIE 10 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.8INTEGER (0..60000)read-writecurrent
setMsiMtie100EL1
OBJECT-TYPE
Set the input port MTIE 100 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.9INTEGER (0..60000)read-writecurrent
setMsiMtie100EL2
OBJECT-TYPE
Set the input port MTIE 100 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.10INTEGER (0..60000)read-writecurrent
setMsiMtie100CL1
OBJECT-TYPE
Set the input port MTIE 100 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.11INTEGER (0..60000)read-writecurrent
setMsiMtie100CL2
OBJECT-TYPE
Set the input port MTIE 100 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.12INTEGER (0..60000)read-writecurrent
setMsiMtie1000EL1
OBJECT-TYPE
Set the input port MTIE 1000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.13INTEGER (0..60000)read-writecurrent
setMsiMtie1000EL2
OBJECT-TYPE
Set the input port MTIE 1000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.14INTEGER (0..60000)read-writecurrent
setMsiMtie1000CL1
OBJECT-TYPE
Set the input port MTIE 1000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.15INTEGER (0..60000)read-writecurrent
setMsiMtie1000CL2
OBJECT-TYPE
Set the input port MTIE 1000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.16INTEGER (0..60000)read-writecurrent
setMsiMtie10000EL1
OBJECT-TYPE
Set the input port MTIE 10000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.17INTEGER (0..60000)read-writecurrent
setMsiMtie10000EL2
OBJECT-TYPE
Set the input port MTIE 10000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.18INTEGER (0..60000)read-writecurrent
setMsiMtie10000CL1
OBJECT-TYPE
Set the input port MTIE 10000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.19INTEGER (0..60000)read-writecurrent
setMsiMtie10000CL2
OBJECT-TYPE
Set the input port MTIE 10000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.20INTEGER (0..60000)read-writecurrent
setMsiMtie100000EL1
OBJECT-TYPE
Set the input port MTIE 100000 seconds error threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.21INTEGER (0..60000)read-writecurrent
setMsiMtie100000EL2
OBJECT-TYPE
Set the input port MTIE 100000 seconds error threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.22INTEGER (0..60000)read-writecurrent
setMsiMtie100000CL1
OBJECT-TYPE
Set the input port MTIE 100000 seconds clear threshold for the first limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.23INTEGER (0..60000)read-writecurrent
setMsiMtie100000CL2
OBJECT-TYPE
Set the input port MTIE 100000 seconds clear threshold for the second limit setting.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.24INTEGER (0..60000)read-writecurrent
setMsiFreqAErrLmt
OBJECT-TYPE
Sets input port frequency error threshold for clock A.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.25INTEGER (0..10000000)read-writecurrent
setMsiFreqAClrLmt
OBJECT-TYPE
Sets input port frequency clear threshold for clock A.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.26INTEGER (0..10000000)read-writecurrent
setMsiFreqATau
OBJECT-TYPE
Sets the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock A.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.27INTEGER (10..1000)read-writecurrent
setMsiFreqBErrLmt
OBJECT-TYPE
Sets input port frequency error threshold for clock B.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.28INTEGER (0..10000000)read-writecurrent
setMsiFreqBClrLmt
OBJECT-TYPE
Sets input port frequency clear threshold for clock B.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.29INTEGER (0..10000000)read-writecurrent
setMsiFreqBTau
OBJECT-TYPE
Sets the time constant (tau), in seconds, used for the calculation of the Average Frequency for clock B.
1.3.6.1.4.1.601.3.1.1.3.18.4.1.30INTEGER (10..1000)read-writecurrent
setupJccOut
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.19
setJccoTable
OBJECT-TYPE
A list of JCC output status and settings.
1.3.6.1.4.1.601.3.1.1.3.19.2not-accessiblecurrent
setJccoEntry
OBJECT-TYPE
Set JCC output attributes.
1.3.6.1.4.1.601.3.1.1.3.19.2.1not-accessiblecurrent
setJccoChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each JCC Output entry.
1.3.6.1.4.1.601.3.1.1.3.19.2.1.1INTEGER (1..5)not-accessiblecurrent
setJccoSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each JCC Output entry.
1.3.6.1.4.1.601.3.1.1.3.19.2.1.2INTEGER (1..20)not-accessiblecurrent
setJccoBypass
OBJECT-TYPE
Set Clock C, or bypass mode, to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.19.2.1.3OnValueread-writecurrent
setJcco400Hz
OBJECT-TYPE
Set the 400Hz BPV removal. A setting OFF removes this 400Hz component, and a setting ON includes it.
1.3.6.1.4.1.601.3.1.1.3.19.2.1.4OnValueread-writecurrent
setJccoEnable
OBJECT-TYPE
Set the JCC output ports to enabled or disabled. 1 = enabled 2 = disabled Note: Byte 1 = port 1, byte 20 = port 20.
1.3.6.1.4.1.601.3.1.1.3.19.2.1.5OCTET STRING (SIZE(20))read-writecurrent
setJccoComp
OBJECT-TYPE
The array represents the output phase compensation for all ports on an output module. Note: Byte 1 = port 1, byte 20 = port 20. The specifed byte value is 1 thru 8. 1 = no delay, 8 = highest delay. The equivalent cable length: 1 = 2200 ft, 2 = 1925 ft, 3 = 1650 ft, 4 = 1375 ft, 5 = 1100 ft, 6 = 825 ft, 7 = 550 ft, 8 = 275 ft.
1.3.6.1.4.1.601.3.1.1.3.19.2.1.6OCTET STRING (SIZE(20))read-writecurrent
setupJccInp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.20
setJccInpTable
OBJECT-TYPE
The list of CC Input attribute setup information.
1.3.6.1.4.1.601.3.1.1.3.20.2not-accessiblecurrent
setJcciEntry
OBJECT-TYPE
Input status and settings attributes.
1.3.6.1.4.1.601.3.1.1.3.20.2.1not-accessiblecurrent
setJcciChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry. Note: The input module can only reside in chassis 1 (main chassis).
1.3.6.1.4.1.601.3.1.1.3.20.2.1.1INTEGER (1)not-accessiblecurrent
setJcciSlot
OBJECT-TYPE
Identifies which slot position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.2INTEGER (1..20)not-accessiblecurrent
setJcciPort
OBJECT-TYPE
Identifies which port position is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.3INTEGER (1..3)not-accessiblecurrent
setJcciEnable
OBJECT-TYPE
Set the input port to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.4EnaValueread-writecurrent
setJcciProvPql
OBJECT-TYPE
Set the input port provisioned Priority Quality Level (PQL). Note: Valid values are 1 - 9.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.5INTEGER (1..9)read-writecurrent
setJcciPriority
OBJECT-TYPE
Set the input port priority level. '0' = monitoring, '1' = highest priority, '10' = lowest priority.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.6INTEGER (0..10)read-writecurrent
setJcci400Hz
OBJECT-TYPE
Set the input port 400Hz signal attribute.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.7OnValueread-writecurrent
setJcciZeroPhase
OBJECT-TYPE
Set the phase error to zero for this input port. ZEROPHA - set phase A error to zero, ZEROPHB - set phase B error to zero, ZEROPHAB - set phase A and B to zero. Note: This field only is meaningful during the write operation.
1.3.6.1.4.1.601.3.1.1.3.20.2.1.8INTEGER {zeroPhA(1), zeroPhB(2), zeroPhAB(3)}read-writecurrent
setupLrmE1
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.21
setLrme1PTable
OBJECT-TYPE
A list of E1 LRM ports status and settings.
1.3.6.1.4.1.601.3.1.1.3.21.2not-accessiblecurrent
setLrme1PEntry
OBJECT-TYPE
Set E1 LRM attributes.
1.3.6.1.4.1.601.3.1.1.3.21.2.1not-accessiblecurrent
setLrme1PChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.1INTEGER (1..5)not-accessiblecurrent
setLrme1PSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.2INTEGER (1..20)not-accessiblecurrent
setLrme1PPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.3INTEGER (1..4)not-accessiblecurrent
setLrme1PEnable
OBJECT-TYPE
Set the LRM ports to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.4OnValueread-writecurrent
setLrme1PSlip
OBJECT-TYPE
Set the slip error threshold in 24 hours period and the value zero shall clear the slip accumulated errors.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.5INTEGER (0..255)read-writecurrent
setLrme1PBpv
OBJECT-TYPE
Clear the accumulated BPV errors clr(1), -- clear the accumulated BPV errors nop(2) -- no operation Note: This field only has meaning for a write operation.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.6INTEGER {clr(1), nop(2)}read-writecurrent
setLrme1PFlt
OBJECT-TYPE
Set the Side 1 fault strategy
1.3.6.1.4.1.601.3.1.1.3.21.2.1.7INTEGER {squelch(1), ais(2)}read-writecurrent
setLrme1PCid
OBJECT-TYPE
Set the circuit id for LRM port The circuit id is an 0-43 character string with all ascii printable characters.
1.3.6.1.4.1.601.3.1.1.3.21.2.1.8DisplayString (SIZE(0..43))read-writecurrent
setupPtNtp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.22
setPtNtpTable
OBJECT-TYPE
A list of PackeTime NTP status and settings.
1.3.6.1.4.1.601.3.1.1.3.22.1not-accessiblecurrent
setPtNtpEntry
OBJECT-TYPE
PackeTime NTP settings and attributes.
1.3.6.1.4.1.601.3.1.1.3.22.1.1not-accessiblecurrent
setPtNtpChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.1INTEGER (1..5)not-accessiblecurrent
setPtNtpSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.2INTEGER (1..20)not-accessiblecurrent
setPtNtpCommit
OBJECT-TYPE
Commit all provisioned parameters, this action makes the parameters active. This command will also store the parameters to non-volatile memory. Note: This field only has meaning for a writing (1).
1.3.6.1.4.1.601.3.1.1.3.22.1.1.3INTEGER {yes(1)}read-writecurrent
setPtNtpProbe
OBJECT-TYPE
Set the PackeTime Maintenance Port state; Enable or Disable. This node is obsolete, The setting is NOP.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.4EnaValueread-writecurrent
setPtNtpBond
OBJECT-TYPE
Set Service port bonding state. 1 = Enabled 2 = Disabled
1.3.6.1.4.1.601.3.1.1.3.22.1.1.5EnaValueread-writecurrent
setPtNtpNTPd
OBJECT-TYPE
Set the NTP daemon state. 1 = Enabled 2 = Disabled
1.3.6.1.4.1.601.3.1.1.3.22.1.1.6EnaValueread-writecurrent
setPtNtpTodsrcPrefer
OBJECT-TYPE
Set the module's preferred time-source to be either TODSRC (1) or PEER (2). TOD Source, either the TODSRC (GPS) or a NTP Peer if operating in Client mode
1.3.6.1.4.1.601.3.1.1.3.22.1.1.7INTEGER {todsrc(1), peer(2)}read-writecurrent
setPtNtpTodsrcPriority
OBJECT-TYPE
Set the Todsrc priority. The priority is the for the specified module as the TOD Source, default is 0, range can be 0 through 8. Value 1 is the highest, and 8 is the lowest. If the value is zero, the specified module cannot be TOD Source.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.8INTEGER (0..8)read-writecurrent
setPtNtpWeight
OBJECT-TYPE
Set the load distribution between portA/B in percent. For example, 70 means port-A get 70% of total bandwidth, port-B gets remaining 30%. If port-A reaches 70% of total bandwidth but port-B has no traffic, the 30% of bandwidth will be wasted, port-A cannot use it. To allow either port to use all the bandwidth, portAWeight can be set to -1, indicating no limit between port-A and port-B (either port-A or port-B can get all the bandwidth, based on first come first serve). Thus the range of this parameter -1 to 100. For bonding mode, this parameter must be forced to -1, so the active port can use 100% of the bandwidth. For non-bonding mode, user can set any value between -1 to 100.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.9INTEGER (-1..100)read-writecurrent
setPtNtpCompensation
OBJECT-TYPE
Set the Antenna cable delay compensation in the case of GPS ToD Source(s) or the delay induced by the cable(s) used to connect expansion shelves where the PackeTime ToD Source(s) is located in relationship to the Main shelf. The time offset shall have a 100nS resolution, thus the Delay value shall be multiplied by 100nS to provide 1PPS compensation. Valid user compensation values range is 0 thru 250 for a total compensation range of 0 to 25000nS (25uS).
1.3.6.1.4.1.601.3.1.1.3.22.1.1.10INTEGER (0..250)read-writecurrent
setPtNtpPeerTimeout
OBJECT-TYPE
Set the Peer Availability Timeout The timer shall have a user settable range from 60 minutes to 10000 minutes, with a default value of 1440 minutes
1.3.6.1.4.1.601.3.1.1.3.22.1.1.11INTEGER (60..10000)read-writecurrent
setPtNtpPeerPrefer
OBJECT-TYPE
Set the preferred peer from the peer list. The valid value is 0-8. The value zero means, there is no prefer. This value has meaning, only when the specified peer is in the peer list.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.12INTEGER (0..8)read-writecurrent
setPtNtpBypass
OBJECT-TYPE
Set the clock C state, or bypass clock, to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.13OnValueread-writecurrent
setPtNtpModActive
OBJECT-TYPE
Set the specified module in the redundant pair to be Active. Note1: This command only applies when the module in the redundant pair. Note2: This field only has meaning for a writing (1). Note3: Don't apply COMMIT after this command.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.14YesValueread-writecurrent
setPtNtpPAActive
OBJECT-TYPE
Set Port A is being manually selected as the active port. Note1: This command only applies when the bonding mode is enabled and both ports are in network and Ethernet link up. Note2: This field only has meaning for a writing (1). Note3: Don't apply COMMIT after this command.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.15YesValueread-writecurrent
setPtNtpPBActive
OBJECT-TYPE
Set Port B is being manually selected as the active port. Note1: This command only applies when the bonding mode is enabled and both ports are in network and Ethernet link up. Note2: This field only has meaning for a writing (1). Note3: Don't apply COMMIT after this command.
1.3.6.1.4.1.601.3.1.1.3.22.1.1.16YesValueread-writecurrent
setPtNtpPortTable
OBJECT-TYPE
PackeTime NTP ethernet port information.
1.3.6.1.4.1.601.3.1.1.3.22.2not-accessiblecurrent
setPtNtpPortEntry
OBJECT-TYPE
PackeTime NTP ethernet port state and settings information. setPtNtpPortChassis Identifies which chassis is being addressed. setPtNtpPortSlot Identifies which slot is being addressed. setPtNtpPortNum Identifies which port is being addressed. setPtNtpPortAddr Set the port IP address setPtNtpPortMask Set the port network mask setPtNtpPortGate Set the port gateway address
1.3.6.1.4.1.601.3.1.1.3.22.2.1not-accessiblecurrent
setPtNtpPortChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and port number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.2.1.1INTEGER (1..5)not-accessiblecurrent
setPtNtpPortSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and port number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.2.1.2INTEGER (1..20)not-accessiblecurrent
setPtNtpPortNum
OBJECT-TYPE
Identifies which port is being addressed. This chassis, slot, and port number uniquely identify each entry. PTNTP ethernet interface number. 1 = Service Port A 2 = Service Port B 3 = Maintenance Port
1.3.6.1.4.1.601.3.1.1.3.22.2.1.3INTEGER (1..3)not-accessiblecurrent
setPtNtpPortAddr
OBJECT-TYPE
Set the port IP address
1.3.6.1.4.1.601.3.1.1.3.22.2.1.4IpAddressread-writecurrent
setPtNtpPortMask
OBJECT-TYPE
Set the port network mask
1.3.6.1.4.1.601.3.1.1.3.22.2.1.5IpAddressread-writecurrent
setPtNtpPortGate
OBJECT-TYPE
Set the port gateway address
1.3.6.1.4.1.601.3.1.1.3.22.2.1.6IpAddressread-writecurrent
setPtNtpPeerTable
OBJECT-TYPE
List of PackeTime NTP Peer entries. Entries are indexed by the values of setPtNtpPeerChassis, setPtNtpPeerSlot and setPtNtpPortNum.
1.3.6.1.4.1.601.3.1.1.3.22.3not-accessiblecurrent
setPtNtpPeerEntry
OBJECT-TYPE
Set PackeTime NTP peer state and settings. setPtNtpPeerChassis Identifies which chassis is being addressed. setPtNtpPeerSlot Identifies which slot is being addressed. setPtNtpPeerNum Identifies which ntp peer is being addressed. setPtNtpPeerAddr Set Peer IP address in peer table. setPtNtpPeerPmin Set the minimum request rate in seconds for CLIENT mode. setPtNtpPeerPmax Set the maximum request rate in seconds for CLIENT mode. setPtNtpPeerKeyId Set keyId to be used to lookup authentication key,
1.3.6.1.4.1.601.3.1.1.3.22.3.1not-accessiblecurrent
setPtNtpPeerChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and peer number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.3.1.1INTEGER (1..5)not-accessiblecurrent
setPtNtpPeerSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and peer number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.3.1.2INTEGER (1..20)not-accessiblecurrent
setPtNtpPeerNum
OBJECT-TYPE
Identifies which ntp peer is being addressed. This chassis, slot, and peer number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.3.1.3INTEGER (1..8)not-accessiblecurrent
setPtNtpPeerAddr
OBJECT-TYPE
Set Peer IP address in peer table. Write zero IP address will delete this IP address from peer table.
1.3.6.1.4.1.601.3.1.1.3.22.3.1.4IpAddressread-writecurrent
setPtNtpPeerPmin
OBJECT-TYPE
Set the minimum request rate in seconds for CLIENT mode, the default is 16, the range is 16, 32, 64, 128, 256, 512, and 1024.
1.3.6.1.4.1.601.3.1.1.3.22.3.1.5INTEGER (16 | 32 | 64 | 128 | 256 | 512 | 1024)read-writecurrent
setPtNtpPeerPmax
OBJECT-TYPE
Set the maximum request rate in seconds for CLIENT mode, the default is 64, the range is 16, 32, 64, 128, 256, 512, and 1024.
1.3.6.1.4.1.601.3.1.1.3.22.3.1.6INTEGER (16 | 32 | 64 | 128 | 256 | 512 | 1024)read-writecurrent
setPtNtpPeerKeyId
OBJECT-TYPE
Set keyId to be used to lookup authentication key, the default is 0 (no authentication), the range is 0 through 65534
1.3.6.1.4.1.601.3.1.1.3.22.3.1.7INTEGER (0..65534)read-writecurrent
setPtNtpAuthTable
OBJECT-TYPE
A list of PackeTime NTP authentication entries. The number of entries are given by the values of setPtNtpAuthChassis, setPtNtpAuthSlot and setPtNtpAuthNum.
1.3.6.1.4.1.601.3.1.1.3.22.4not-accessiblecurrent
setPtNtpAuthEntry
OBJECT-TYPE
Set PackeTime NTP authentication state and settings. PackeTime NTP authentication attributes. setPtNtpAuthChassis Identifies which chassis is being addressed. setPtNtpAuthSlot Identifies which slot is being addressed. setPtNtpAuthNum Identifies which authentication key is being addressed. setPtNtpAuthKeyId Set the authentication key ID, setPtNtpAuthKeyValue Set the NTP authentication key used to create the MD5 hash associated with the keyid.
1.3.6.1.4.1.601.3.1.1.3.22.4.1not-accessiblecurrent
setPtNtpAuthChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and authentication key number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.4.1.1INTEGER (1..5)not-accessiblecurrent
setPtNtpAuthSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and authentication key number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.4.1.2INTEGER (1..20)not-accessiblecurrent
setPtNtpAuthNum
OBJECT-TYPE
Identifies which authentication key is being addressed. This chassis, slot, and authentication key number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.4.1.3INTEGER (1..16)not-accessiblecurrent
setPtNtpAuthKeyId
OBJECT-TYPE
Set KeyId is the authentication key ID, default is 0 (no authentication), range 0 to 65534. Note: If this value is zero, no authentication is used.
1.3.6.1.4.1.601.3.1.1.3.22.4.1.4INTEGER (0..65534)read-writecurrent
setPtNtpAuthKeyValue
OBJECT-TYPE
Set the key is the NTP authentication key used to create the MD5 hash associated with the keyid. The key is a comprised of up to 32 ASCII characters, a minimum of 8 characters is required. Note: the key value will not display and it is always displayed as null string.
1.3.6.1.4.1.601.3.1.1.3.22.4.1.5DisplayString (SIZE(0 | 8..32))read-writecurrent
setPtNtpRouteTable
OBJECT-TYPE
A list of PackeTime NTP route table entries. Static routing describes a system that does not implement adaptive routing. In these systems routes through a data network are described by fixed paths (statically). These routes are usually entered into the host by the system administrator.
1.3.6.1.4.1.601.3.1.1.3.22.5not-accessiblecurrent
setPtNtpRouteEntry
OBJECT-TYPE
A PackeTime NTP route attributes and settings. setPtNtpRouteChassis Identifies which chassis is being addressed. setPtNtpRouteSlot Identifies which slot is being addressed. setPtNtpRouteNum Identifies which route number (index) is being addressed. setPtNtpRouteAddr Set the route destination network or destination host. setPtNtpRouteMask Set the netmask for the destination network. setPtNtpRouteGate Set the gateway ip for the destination network. setPtNtpRouteIface Set the module's network interface number.
1.3.6.1.4.1.601.3.1.1.3.22.5.1not-accessiblecurrent
setPtNtpRouteChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and route number (index) uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.5.1.1INTEGER (1..5)not-accessiblecurrent
setPtNtpRouteSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and route number (index) uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.5.1.2INTEGER (1..20)not-accessiblecurrent
setPtNtpRouteNum
OBJECT-TYPE
Identifies which route number is being addressed. This chassis, slot, and route number (index) uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.5.1.3INTEGER (1..6)not-accessiblecurrent
setPtNtpRouteAddr
OBJECT-TYPE
Set the route destination network or destination host. Write a new Route IP address will put this new IP into table. Write zero IP address will delete this IP address from table.
1.3.6.1.4.1.601.3.1.1.3.22.5.1.4IpAddressread-writecurrent
setPtNtpRouteMask
OBJECT-TYPE
Set the netmask for the destination network; '255.255.255.255' for a host destination and '0.0.0.0' for the default route
1.3.6.1.4.1.601.3.1.1.3.22.5.1.5IpAddressread-writecurrent
setPtNtpRouteGate
OBJECT-TYPE
Set the gateway for the destination network.
1.3.6.1.4.1.601.3.1.1.3.22.5.1.6IpAddressread-writecurrent
setPtNtpRouteIface
OBJECT-TYPE
Set the module's network interface number: 1 = Service Port A 2 = Service Port B 3 = Bond0 (bonding of PortA and Port B)
1.3.6.1.4.1.601.3.1.1.3.22.5.1.7INTEGER (1..3)read-writecurrent
setPtNtpVlanTable
OBJECT-TYPE
List of PackeTime NTP vlan attributes. The Virtural Local Area Network is implemented per IEEE 802.1Q.
1.3.6.1.4.1.601.3.1.1.3.22.6not-accessiblecurrent
setPtNtpVlanEntry
OBJECT-TYPE
A PackeTime NTP vlan attributes and settings: setPtNtpVlanChassis Identifies which chassis is being addressed. setPtNtpVlanSlot Identifies which slot is being addressed. setPtNtpVlan Set the VLAN state. setPtNtpVlanPAId Set the VLAN ID for Service Port A. setPtNtpVlanPAPriority Set the VLAN priority for Service Port A. setPtNtpVlanPBId Set the VLAN ID for Service Port B. setPtNtpVlanPBPriority Set the VLAN priority for Service Port B. setPtNtpVlanBondId Set the VLAN ID for Bonding of Service Ports of A and B setPtNtpVlanBondPriority Set the VLAN priority for Bonding of Service Ports of A and B
1.3.6.1.4.1.601.3.1.1.3.22.6.1not-accessiblecurrent
setPtNtpVlanChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.6.1.1INTEGER (1..5)not-accessiblecurrent
setPtNtpVlanSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.22.6.1.2INTEGER (1..20)not-accessiblecurrent
setPtNtpVlan
OBJECT-TYPE
Set the VLAN state. 1 = Enabled 2 = Disabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.3EnaValueread-writecurrent
setPtNtpVlanPAId
OBJECT-TYPE
Set the VLAN ID for Service Port A, [0 - 4094] Note: The value has no meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.4INTEGER (0..4094)read-writecurrent
setPtNtpVlanPAPriority
OBJECT-TYPE
Set the VLAN Priority for Service Port A, [0 - 7] Note: The value has no meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.5INTEGER (0..7)read-writecurrent
setPtNtpVlanPBId
OBJECT-TYPE
Set the VLAN ID for Service Port B, [0 - 4094] Note: The value has no meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.6INTEGER (0..4094)read-writecurrent
setPtNtpVlanPBPriority
OBJECT-TYPE
Set the VLAN Priority for Service Port B, [0 - 7] Note: The value has no meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.7INTEGER (0..7)read-writecurrent
setPtNtpVlanBondId
OBJECT-TYPE
Set the VLAN ID for Bonding of Service Ports of A and B, [0 - 4094] Note: The value has no meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.8INTEGER (0..4094)read-writecurrent
setPtNtpVlanBondPriority
OBJECT-TYPE
Set the VLAN Priority for Bonding of Service Ports of A and B, [0 - 7] Note: The value has no meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.22.6.1.9INTEGER (0..7)read-writecurrent
setupPtPtp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.23
setPtPtpTable
OBJECT-TYPE
A list of PackeTime PTP status and settings.
1.3.6.1.4.1.601.3.1.1.3.23.1not-accessiblecurrent
setPtPtpEntry
OBJECT-TYPE
The enties of the PackeTime PTP settings and attributes.
1.3.6.1.4.1.601.3.1.1.3.23.1.1not-accessiblecurrent
setPtPtpChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.1INTEGER (1..5)not-accessiblecurrent
setPtPtpSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.2INTEGER (1..20)not-accessiblecurrent
setPtPtpCommit
OBJECT-TYPE
Commit all provisioned parameters, this action makes the parameters active. This command will also store the parameters to non-volatile memory. Note: This field only has meaning for a writing (1).
1.3.6.1.4.1.601.3.1.1.3.23.1.1.3INTEGER {yes(1)}read-writecurrent
setPtPtpService
OBJECT-TYPE
Set the PTP service (daemon) to enable or disable. This command is applied to both modules if redundant cards installed. 1 = Enabled 2 = Disabled
1.3.6.1.4.1.601.3.1.1.3.23.1.1.4EnaValueread-writecurrent
setPtPtpClockId
OBJECT-TYPE
Set the clockId is the PTP Port Clock Identity (64-bit value). The clockid is a hexadecimal format. Note: users shall enter command COMMIT to take changes into effect
1.3.6.1.4.1.601.3.1.1.3.23.1.1.5OCTET STRING (SIZE(8))read-writecurrent
setPtPtpDomain
OBJECT-TYPE
Set the PTP port domain. Note: users shall enter command COMMIT to take changes into effect
1.3.6.1.4.1.601.3.1.1.3.23.1.1.6INTEGER (0..255)read-writecurrent
setPtPtpTimescale
OBJECT-TYPE
Set timescale to 'PTP' or 'ARB'. Note: users shall enter command COMMIT to take changes into effect
1.3.6.1.4.1.601.3.1.1.3.23.1.1.7INTEGER {ptp(1), arb(2)}read-writecurrent
setPtPtpSyncLimit
OBJECT-TYPE
Set the unicast Sync message rate (2^y). The range of the rate value is {-7 to 7}. For example, the configurable range is -7, means 128 per second
1.3.6.1.4.1.601.3.1.1.3.23.1.1.8INTEGER (-7..7)read-writecurrent
setPtPtpAnnounceLimit
OBJECT-TYPE
Set unicast announce message rate (2^y). The range of the rate value is {-3 to 4}. For example, the configurable range is -3, means 8 per second
1.3.6.1.4.1.601.3.1.1.3.23.1.1.9INTEGER (-3..4)read-writecurrent
setPtPtpDelayLimit
OBJECT-TYPE
Set unicast delay resp message rate (2^y). The range of the rate value is {-7 to 7}. For example, the configurable range is -6, means 64 per second
1.3.6.1.4.1.601.3.1.1.3.23.1.1.10INTEGER (-7..7)read-writecurrent
setPtPtpDscpState
OBJECT-TYPE
Set the DSCP state to enable or disable.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.11EnaValueread-writecurrent
setPtPtpDscpValue
OBJECT-TYPE
Set DSCP value.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.12INTEGER (0..63)read-writecurrent
setPtPtpMaxClient
OBJECT-TYPE
Set the PTP max clients.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.13INTEGER (64..400)read-writecurrent
setPtPtpPortPriority1
OBJECT-TYPE
Set the PTP Port Priority 1 {0 to 255}.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.14INTEGER (0..255)read-writecurrent
setPtPtpPortPriority2
OBJECT-TYPE
Set the PTP Port Priority 2 {0 to 255}.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.15INTEGER (0..255)read-writecurrent
setPtPtpUniLeaseDuration
OBJECT-TYPE
Set the PTP Max Dynamic Unicast Lease Interval, {10 to 1000}
1.3.6.1.4.1.601.3.1.1.3.23.1.1.16INTEGER (10..1000)read-writecurrent
setPtPtpUniNegotiation
OBJECT-TYPE
Set the PTP Unicast Negotiation state: Enable or Disable
1.3.6.1.4.1.601.3.1.1.3.23.1.1.17EnaValueread-writecurrent
setPtPtpTwostep
OBJECT-TYPE
Set the PTP Two-Step clock state: Enable or Disable Note: users shall enter command COMMIT to take changes into effect
1.3.6.1.4.1.601.3.1.1.3.23.1.1.18EnaValueread-writecurrent
setPtPtpProfile
OBJECT-TYPE
Set PTP profile telecom_2008 or itu_g8265_1. Note: users shall enter command COMMIT to take changes into effect
1.3.6.1.4.1.601.3.1.1.3.23.1.1.19INTEGER {telecom2008(1), ituG8265dot1(4)}read-writecurrent
setPtPtpSsmOption
OBJECT-TYPE
Set PTP ssm-option in Option 1 or Option 2.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.20INTEGER {option1(1), option2(2)}read-writecurrent
setPtPtpBypass
OBJECT-TYPE
Set the clock C state, or bypass clock, to enabled or disabled.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.30OnValueread-writecurrent
setPtPtpModActive
OBJECT-TYPE
Set the specified module in the redundant pair to be Active. Note1: This command only applies when the module in the redundant pair. Note2: This field only has meaning for a writing (1). Note3: Don't apply COMMIT after this command.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.31YesValueread-writecurrent
setPtPtpEthRate
OBJECT-TYPE
Set the PTP port transmission rate. all - means auto negotiation capable of both 100M and 1000Mbits/s rate. r100 - means auto negotiation capable of only 100Mbit/s rate. r1000 - means auto negotiation capable of only 1000Mbit/s rate Note: this setting is only applied to the copper SFP, not fiber. If fiber SFP installed, this setting is ignored.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.32INTEGER {all(0), r100(1), r1000(2)}read-writecurrent
setPtPtpVlan
OBJECT-TYPE
Set the VLAN state. 1 = Enabled 2 = Disabled Users must COMMIT for changes into effect.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.33EnaValueread-writecurrent
setPtPtpRmvClient
OBJECT-TYPE
This is an action command and not a configuration command. This command remove a client from a ptp client list. The clockid is a hexadecimal format. Note: this field only has meansing for write action with proper clock id. When it read, it always returns as all zero octet string.
1.3.6.1.4.1.601.3.1.1.3.23.1.1.34OCTET STRING (SIZE(8))read-writecurrent
setPtpPortTable
OBJECT-TYPE
Set PackeTime PTP ethernet port information.
1.3.6.1.4.1.601.3.1.1.3.23.2not-accessiblecurrent
setPtpPortEntry
OBJECT-TYPE
PackeTime PTP ethernet port state and settings information. setPtPtpPortChassis Identifies which chassis is being addressed. setPtPtpPortSlot Identifies which slot is being addressed. setPtPtpPortNum Identifies which port is being addressed. setPtPtpPortAddr Set the port IP address setPtPtpPortMask Set the port network mask setPtPtpPortGate Set the port gateway address
1.3.6.1.4.1.601.3.1.1.3.23.2.1not-accessiblecurrent
setPtpPortChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and port number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.23.2.1.1INTEGER (1..5)not-accessiblecurrent
setPtpPortSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and port number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.23.2.1.2INTEGER (1..20)not-accessiblecurrent
setPtpPortNum
OBJECT-TYPE
Identifies which port is being addressed. This chassis, slot, and port number uniquely identify each entry. PTPTP ethernet interface number. 1 = Service Port A 2 = Maintenance Port
1.3.6.1.4.1.601.3.1.1.3.23.2.1.3INTEGER (1..2)not-accessiblecurrent
setPtpPortAddr
OBJECT-TYPE
Set the port IP address
1.3.6.1.4.1.601.3.1.1.3.23.2.1.4IpAddressread-writecurrent
setPtpPortMask
OBJECT-TYPE
Set the port network mask
1.3.6.1.4.1.601.3.1.1.3.23.2.1.5IpAddressread-writecurrent
setPtpPortGate
OBJECT-TYPE
Set the port gateway address
1.3.6.1.4.1.601.3.1.1.3.23.2.1.6IpAddressread-writecurrent
setPtpVlanTable
OBJECT-TYPE
List of PackeTime PTP vlan attributes. The Virtural Local Area Network is implemented per IEEE 802.1Q.
1.3.6.1.4.1.601.3.1.1.3.23.3not-accessiblecurrent
setPtpVlanEntry
OBJECT-TYPE
A PackeTime PTP vlan attributes and settings: setPtPtpVlanChassis Identifies which chassis is being addressed. setPtPtpVlanSlot Identifies which slot is being addressed. setPtpVlanIndex Set the VLAN index number for PTPTP. setPtpVlanState Enable or Disable of a given VLAN Entry setPtpVlanAddr VLAN IP Address (If 0.0.0.0, and then SET, this will delete this entry) note: This field has to set first with a valid non-zero IP address, if you want to add a new entry setPtpVlanMask VLAN Network Mask setPtpVlanGate VLAN Gateway setPtpVlanId VLAN ID setPtpVlanPriority VLAN Priority Note: The module setPtPtpVlan set must be enabled, and each of the enabled entires has meaning.
1.3.6.1.4.1.601.3.1.1.3.23.3.1not-accessiblecurrent
setPtpVlanChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.23.3.1.1INTEGER (1..5)not-accessiblecurrent
setPtpVlanSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.23.3.1.2INTEGER (1..20)not-accessiblecurrent
setPtpVlanIndex
OBJECT-TYPE
Set the VLAN index number for PTP.
1.3.6.1.4.1.601.3.1.1.3.23.3.1.3INTEGER (1..4)not-accessiblecurrent
setPtpVlanState
OBJECT-TYPE
Enable or Disable of a given VLAN entry Note: The value has meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.23.3.1.4EnaValueread-writecurrent
setPtpVlanAddr
OBJECT-TYPE
Ethernet VLAN Port IP Address Note: you must have IP address in order to add or change other fields. This field has to set first with a valid non-zero IP address, if you want to add a new entry If the IP is 0.0.0.0, and use the SET operation, this mean delete this entry.
1.3.6.1.4.1.601.3.1.1.3.23.3.1.5IpAddressread-writecurrent
setPtpVlanMask
OBJECT-TYPE
Ethernet VLAN Port Network Mask
1.3.6.1.4.1.601.3.1.1.3.23.3.1.6IpAddressread-writecurrent
setPtpVlanGate
OBJECT-TYPE
Ethernet VLAN Port Gateway Address
1.3.6.1.4.1.601.3.1.1.3.23.3.1.7IpAddressread-writecurrent
setPtpVlanId
OBJECT-TYPE
Set the VLAN ID (2..4094) for Service Port A Note: The value has meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.23.3.1.8INTEGER (2..4094)read-writecurrent
setPtpVlanPriority
OBJECT-TYPE
VLAN Priority (0..7) for Service Port A Note: The value has meaning, only when the VLAN is enabled
1.3.6.1.4.1.601.3.1.1.3.23.3.1.9INTEGER (0..7)read-writecurrent
setupSynce
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.3.24
setSynceTable
OBJECT-TYPE
A list of SyncE settings.
1.3.6.1.4.1.601.3.1.1.3.24.1not-accessiblecurrent
setSynceEntry
OBJECT-TYPE
The enties of the SyncE settings and attributes.
1.3.6.1.4.1.601.3.1.1.3.24.1.1not-accessiblecurrent
setSynceChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.24.1.1.1INTEGER (1..5)not-accessiblecurrent
setSynceSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.3.24.1.1.2INTEGER (1..20)not-accessiblecurrent
setSyncePortDirection
OBJECT-TYPE
Set SyncE Port Direction to be either Output or Input. The output port is a SyncE master port, and input port is a SyncE slave port.
1.3.6.1.4.1.601.3.1.1.3.24.1.1.3INTEGER {input(1), output(2)}read-writecurrent
setSynceEsmc
OBJECT-TYPE
Set the Ethernet Synchronization Message Channel (ESMC) state is either Enable or Disable. If ESMC is enabled, the ESMC is used; otherwise, it shall not be used.
1.3.6.1.4.1.601.3.1.1.3.24.1.1.4EnaValueread-writecurrent
setSynceQl
OBJECT-TYPE
Set the Quality Level (QL, i.e. SSM) in the ESMC is either Enabled or Disabled. If QL is enabled, the SSM in the ESMC is used; otherwise, it shall not be used.
1.3.6.1.4.1.601.3.1.1.3.24.1.1.5EnaValueread-writecurrent
setSynceOutQl
OBJECT-TYPE
Set the Output QL mode is either unidirectional or bidirectional. In the unidirectional mode, the rx ESMC from the downstream NE is ignored. The tx SSM will be determined by the system clock state only. In the bidirectional mode, the rx ESMC from the downstream NE is not ignored but is used for testing purposes and some interoperability cases.
1.3.6.1.4.1.601.3.1.1.3.24.1.1.6INTEGER {bidirectional(1), unidirectional(2)}read-writecurrent
general
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.4
infoTable
OBJECT-TYPE
A list of general information entries.
1.3.6.1.4.1.601.3.1.1.4.1not-accessiblecurrent
giEntry
OBJECT-TYPE
Set global module attributes.
1.3.6.1.4.1.601.3.1.1.4.1.1not-accessiblecurrent
giChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.4.1.1.1INTEGER (1..5)not-accessiblecurrent
giSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number and slot number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.4.1.1.2INTEGER (1..20)not-accessiblecurrent
giSystime
OBJECT-TYPE
Reports length of time (in seconds) a specified module has been operational since last reboot. Only apply to the CPU-based module. zero means Not Applicable.
1.3.6.1.4.1.601.3.1.1.4.1.1.3Counter32read-onlycurrent
giElevation
OBJECT-TYPE
The module alarm elevation time (in seconds). Each module in the system can be set for elevation time from 60 seconds to 500,000 seconds. A setting of 0 (zero) means no elevation for the alarm. For example, when an alarm has been at MINOR level ontinuously for elevtime seconds, then it is elevated to the next level (MAJOR). Note: 0 = disabled.
1.3.6.1.4.1.601.3.1.1.4.1.1.4INTEGER (0 | 60..500000)read-writecurrent
giSetup
OBJECT-TYPE
Saves or restores the configuration of the specified module. FACTORY - restores the module configuration to factory defaults. SAVE - will save the current configuration as User. USER - will restore the saved User configuration. Note: This field only has meaning for a write operation. Only apply to the CPU-based module.
1.3.6.1.4.1.601.3.1.1.4.1.1.5INTEGER {factory(1), user(2), save(3)}read-writecurrent
giRestart
OBJECT-TYPE
Restarts a module. Writing a '1' to this variable restarts (reboots) the module. Note: This field only has meaning for a write operation. Only apply to the CPU-based module.
1.3.6.1.4.1.601.3.1.1.4.1.1.6YesValueread-writecurrent
event
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.5
evCount
OBJECT-TYPE
Reports total number of events to display. The number represents total number of events we want to display. Its value ranges between 1 and 1000.
1.3.6.1.4.1.601.3.1.1.5.1INTEGER (1..1000)read-writecurrent
evType
OBJECT-TYPE
Reports which event type we want to display (functions as a display filter). Set these values to the desired type you want to display: ALARM - for alarm type REPORT - for event type ALL - for all (alarm and event) type.
1.3.6.1.4.1.601.3.1.1.5.2INTEGER {alarm(1), report(2), all(3)}read-writecurrent
eventTable
OBJECT-TYPE
Report of system event entries. The number of entries is given by the value of evNumber. The total entries are up to 1000.
1.3.6.1.4.1.601.3.1.1.5.3not-accessiblecurrent
evEntry
OBJECT-TYPE
An event entry containing objects of each event.
1.3.6.1.4.1.601.3.1.1.5.3.1not-accessiblecurrent
evIndex
OBJECT-TYPE
A unique value for each event. This value range from 1 to 1000.
1.3.6.1.4.1.601.3.1.1.5.3.1.1INTEGER (1..1000)not-accessiblecurrent
evT
OBJECT-TYPE
A OCTET STRING containing information about the event. The string is in the TLV format, and contains following information: INTEGER - event id INTEGER - module hex code DateAndTime - timestamp INTEGER - chassis number INTEGER - slot number INTEGER - port number INTEGER - alarm code INTEGER - notification code INTEGER - Elevated DisplayString - ascii string description of the event event id: INTEGER (0..255) Alarm Code: minor(1), major(2), critical(3), ignore(4), report(5), Notification Code: minor(1), major(2), critical(3), ignore(4), report(5), clear(6) Elevated: Yes(1), No(2)
1.3.6.1.4.1.601.3.1.1.5.3.1.2OCTET STRING (SIZE(36..116))read-onlycurrent
alarm
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.6
alarmTable
OBJECT-TYPE
A list of alarm entries.
1.3.6.1.4.1.601.3.1.1.6.1not-accessiblecurrent
almEntry
OBJECT-TYPE
Alarm entry attributes.
1.3.6.1.4.1.601.3.1.1.6.1.1not-accessiblecurrent
almChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.6.1.1.1INTEGER (1..5)not-accessiblecurrent
almSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.6.1.1.2INTEGER (1..20)not-accessiblecurrent
almPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.6.1.1.3INTEGER (1..3)not-accessiblecurrent
almIndex
OBJECT-TYPE
Reports the alarm index value. Note: The alarm id is allowed for number zero; therefore, the OID for this index is alarm id plus 1 to avoid the zero number for OID.
1.3.6.1.4.1.601.3.1.1.6.1.1.4INTEGER (1..32)not-accessiblecurrent
almId
OBJECT-TYPE
Reports the alarm id. Note: This is the actual alarm id range 0 thru 31.
1.3.6.1.4.1.601.3.1.1.6.1.1.5INTEGER (0..31)read-onlycurrent
almName
OBJECT-TYPE
Reports the text string to describe this alarm.
1.3.6.1.4.1.601.3.1.1.6.1.1.6DisplayString (SIZE(0..20))read-onlycurrent
almLevel
OBJECT-TYPE
Reports current state of alarm indications on the units. minor(1), major(2), critical(3), ignore(4), report(5), clear(6)
1.3.6.1.4.1.601.3.1.1.6.1.1.7INTEGER {minor(1), major(2), critical(3), ignore(4), report(5), clear(6)}read-onlycurrent
almElevate
OBJECT-TYPE
Report alarm elevation state 1 = alarm elevated 2 = alarm not elevated
1.3.6.1.4.1.601.3.1.1.6.1.1.8YesValueread-onlycurrent
almStatus
OBJECT-TYPE
Reports the text string to describe this alarm status condition.
1.3.6.1.4.1.601.3.1.1.6.1.1.9DisplayString (SIZE(0..20))read-onlycurrent
setAlmLoc
OBJECT-TYPE
Set the module slot location. It should be one module, multiple module is not allowed where x is the chassis number: the range is 1 to 5, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number. range is [1 to 20]. For example: 1A3-1 for module located in chassis 1 and slot 3, port 1. Note: The slot location must be physically installed in the unit.
1.3.6.1.4.1.601.3.1.1.6.2DisplayString (SIZE(0..10))read-writecurrent
setAlmTable
OBJECT-TYPE
A list of alarm entries.
1.3.6.1.4.1.601.3.1.1.6.3not-accessiblecurrent
salEntry
OBJECT-TYPE
Set alarm attributes.
1.3.6.1.4.1.601.3.1.1.6.3.1not-accessiblecurrent
salChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.6.3.1.1INTEGER (1..5)not-accessiblecurrent
salSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.6.3.1.2INTEGER (1..20)not-accessiblecurrent
salPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.6.3.1.3INTEGER (1..3)not-accessiblecurrent
salIndex
OBJECT-TYPE
Index value for the alarm. Note: The alarm id is allowed for number zero; therefore, the OID for this index is alarm id plus 1 to avoid the zero number for OID.
1.3.6.1.4.1.601.3.1.1.6.3.1.4INTEGER (1..32)not-accessiblecurrent
salId
OBJECT-TYPE
ID value for the alarm. Note: This is the actual alarm id range 0 thru 31.
1.3.6.1.4.1.601.3.1.1.6.3.1.5INTEGER (0..31)read-onlycurrent
salName
OBJECT-TYPE
Name/Description for the alarm.
1.3.6.1.4.1.601.3.1.1.6.3.1.6DisplayString (SIZE(0..20))read-onlycurrent
salSet
OBJECT-TYPE
Alarm state for the alarm: 1 = alarm set 2 = no alarm
1.3.6.1.4.1.601.3.1.1.6.3.1.7YesValueread-onlycurrent
salElevate
OBJECT-TYPE
Alarm elevation status: 1 = alarm elevated 2 = alarm not elevated
1.3.6.1.4.1.601.3.1.1.6.3.1.8YesValueread-onlycurrent
salLevel
OBJECT-TYPE
Sets alarm severe level are: MINOR - sets alarm level to MINOR MAJOR - set alarm level to MAJOR CRITICAL - sets alarm level to CRITICAL IGNORE - ignore any alarm indication REPORT - report only any alarm indication
1.3.6.1.4.1.601.3.1.1.6.3.1.9INTEGER {minor(1), major(2), critical(3), ignore(4), report(5)}read-writecurrent
salDelay
OBJECT-TYPE
Sets the length of time in seconds an alarm must be active before generating an alarm. Note: 0 = user selected immediate indication -1 (when read) = forced immediate indication (i.e. not user selectable)
1.3.6.1.4.1.601.3.1.1.6.3.1.10INTEGER (-1 | 0..86400)read-writecurrent
ref
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.7
refClk
OBJECT-TYPE
Report/Set which clk is currently selected. clka(1), clkb(2), none(3) Note: When read, it shows which clock is currently selected. When write, only clka or clkb are valid.
1.3.6.1.4.1.601.3.1.1.7.1INTEGER {clka(1), clkb(2), none(3)}read-writecurrent
refInp
OBJECT-TYPE
Report/Set the input reference port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. The NULL string means there is no input reference.
1.3.6.1.4.1.601.3.1.1.7.2DisplayString (SIZE(0..10))read-writecurrent
refBypass
OBJECT-TYPE
Report/Set input port designated as the input bypass clock. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. The NULL string means there is no bypass clock. Note: In the SSU2000, the input module always resides in the main chassis (i.e. 'x' is one).
1.3.6.1.4.1.601.3.1.1.7.3DisplayString (SIZE(0..10))read-onlycurrent
refClkSwitch
OBJECT-TYPE
Report/Set Clock auto-return (AR) mode. ar(1), off(2) The AR option changes the current clock selection mode to revertive operation.
1.3.6.1.4.1.601.3.1.1.7.4INTEGER {ar(1), off(2)}read-writecurrent
refInpSwitch
OBJECT-TYPE
Report/Set input switch mode. The InpSwitch settings are: AR = Auto Return (revertive) AS = Auto Switch (but not revertive) OFF = No auto switching
1.3.6.1.4.1.601.3.1.1.7.5INTEGER {ar(1), as(2), off(3)}read-writecurrent
refInpSelection
OBJECT-TYPE
Report/Set input selection mode. The input reference selection can be PRIORITY/ PQL. PRIORITY - the user assigned priority number is used to pick the best input port as an input reference. PQL - the input Priority Quality Level (PQL) is used to select which is the best input port reference.
1.3.6.1.4.1.601.3.1.1.7.6INTEGER {priority(1), pql(2)}read-writecurrent
refClkTodsrc
OBJECT-TYPE
Report/Set TOD Source. The value can be any TOD source candidate (GPS or PackeTime) indicates the TODSRC of the selected clock. The text string of the todsrc reference port. The format is defined as xAy. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) For example: 1A3 means this reference located at chassis 1, slot 3. The NULL string means there is no reference.
1.3.6.1.4.1.601.3.1.1.7.7DisplayString (SIZE(0..10))read-writecurrent
phase
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.8
phaseTable
OBJECT-TYPE
A list of phase data entries.
1.3.6.1.4.1.601.3.1.1.8.1not-accessiblecurrent
phEntry
OBJECT-TYPE
Phase data entry attributes.
1.3.6.1.4.1.601.3.1.1.8.1.1not-accessiblecurrent
phChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.8.1.1.1INTEGER (1)not-accessiblecurrent
phSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.8.1.1.2INTEGER (1..20)not-accessiblecurrent
phPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.8.1.1.3INTEGER (1..3)not-accessiblecurrent
phA
OBJECT-TYPE
Current 1-second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.4OCTET STRING (SIZE(16))read-onlycurrent
phB
OBJECT-TYPE
Current 1-second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.5OCTET STRING (SIZE(16))read-onlycurrent
ph100A
OBJECT-TYPE
Current 100-second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.6OCTET STRING (SIZE(16))read-onlycurrent
ph100B
OBJECT-TYPE
Current 100-second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.7OCTET STRING (SIZE(16))read-onlycurrent
ph1000A
OBJECT-TYPE
Current 1000-second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.8OCTET STRING (SIZE(16))read-onlycurrent
ph1000B
OBJECT-TYPE
Current 1000-second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.9OCTET STRING (SIZE(16))read-onlycurrent
ph10000A
OBJECT-TYPE
Current 10000-second phase value in nanoseconds on clock A. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.10OCTET STRING (SIZE(16))read-onlycurrent
ph10000B
OBJECT-TYPE
Current 10000-second phase value in nanoseconds on clock B. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and contains following information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.1.1.11OCTET STRING (SIZE(16))read-onlycurrent
phHisInpLoc
OBJECT-TYPE
Select input port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1 Note: the user must specify valid input port address. The valid port must be physically installed in the system. Note: In the SSU2000, the input is located at main chassis, the 'x' number is always one.
1.3.6.1.4.1.601.3.1.1.8.2DisplayString (SIZE(0..10))read-writecurrent
phHisTimeAvg
OBJECT-TYPE
Reports time (seconds) interval of phase value. t1 (4000 second time interval), t100 (1000 second time interval), t1000 (1000 second time interval), t10000 (10000 second time interval) Note: T1 data is only available for ports configured for this function, maximum of 5 ports.
1.3.6.1.4.1.601.3.1.1.8.3INTEGER {t100(100), t1000(1000), t10000(10000)}read-writecurrent
phHisClk
OBJECT-TYPE
Reports which clock is used as the reference in the phase measurement.
1.3.6.1.4.1.601.3.1.1.8.4INTEGER {clka(1), clkb(2)}read-writecurrent
phHisCnt
OBJECT-TYPE
Count of phase measurement history requested from the phase history buffer. The maximum phase history in buffer are: T100 = 7000, T1000 = 700, T10000 = 70, Default value = 10.
1.3.6.1.4.1.601.3.1.1.8.5INTEGER (1..7000)read-writecurrent
phHisTable
OBJECT-TYPE
A list of phase history entries. The number of entries is given by the value of phHisCnt. The total entries are up to 7000. Note: this table is based upon the following values: phHisInpLoc - the location of the input port phHisTimeAvg - the time (seconds) interval of phase value phHisCnt - total amount of phase history to return.
1.3.6.1.4.1.601.3.1.1.8.6not-accessiblecurrent
phHisEntry
OBJECT-TYPE
A phase entry attributes: phHisChassis Identifies which chassis is being addressed. phHisSlot Identifies which slot is being addressed. phHisPort Identifies which port is being addressed. phHisIndex Count/ID value for each phase. phHisV Phase value in nanoseconds defined in phHisTimeAvg.
1.3.6.1.4.1.601.3.1.1.8.6.1not-accessiblecurrent
phHisChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.8.6.1.1INTEGER (1)not-accessiblecurrent
phHisSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.8.6.1.2INTEGER (1..20)not-accessiblecurrent
phHisPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.8.6.1.3INTEGER (1..3)not-accessiblecurrent
phHisIndex
OBJECT-TYPE
Count/ID value for each phase. Valid range : 1 - 7000.
1.3.6.1.4.1.601.3.1.1.8.6.1.4INTEGER (1..7000)not-accessiblecurrent
phHisV
OBJECT-TYPE
Phase value in nanoseconds defined in phHisTimeAvg. The 1,999,999,999 is designated for invalid phase value. The string is in the TLV format, and containsfollowing information: DateAndTime - timestamp INTEGER - phase value
1.3.6.1.4.1.601.3.1.1.8.6.1.5OCTET STRING (SIZE(16))read-onlycurrent
freq
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.9
freqTable
OBJECT-TYPE
A list of frequency entries for each input port.
1.3.6.1.4.1.601.3.1.1.9.1not-accessiblecurrent
fqEntry
OBJECT-TYPE
Frequency entry attributes: fqChassis INTEGER, fqSlot INTEGER, fqPort INTEGER, fqA OCTET STRING, fqB
1.3.6.1.4.1.601.3.1.1.9.1.1not-accessiblecurrent
fqChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.9.1.1.1INTEGER (1)not-accessiblecurrent
fqSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.9.1.1.2INTEGER (1..20)not-accessiblecurrent
fqPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.9.1.1.3INTEGER (1..3)not-accessiblecurrent
fqA
OBJECT-TYPE
Current frequency measurement versus clock A. The 1,999,999,999 is designated for invalid frequency value. DateAndTime - timestamp INTEGER - frequency value
1.3.6.1.4.1.601.3.1.1.9.1.1.4OCTET STRING (SIZE(16))read-onlycurrent
fqB
OBJECT-TYPE
Current frequency measurement versus clock B. The 1,999,999,999 is designated for invalid frequency value. DateAndTime - timestamp INTEGER - frequency value
1.3.6.1.4.1.601.3.1.1.9.1.1.5OCTET STRING (SIZE(16))read-onlycurrent
ntp
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.10
ntpMode
OBJECT-TYPE
Current NTP mode in the system. SERVER - The system has a GPS module installed and has UTC time. CLIENT - The system has a valid Client peer entry in the NTP Table, and is synced with its associated Server. LOCAL - The sytem is running its own clock and has its own time.
1.3.6.1.4.1.601.3.1.1.10.1INTEGER {server(1), client(2), local(3)}read-onlycurrent
ntpSysPeer
OBJECT-TYPE
This is the system peer IP address.
1.3.6.1.4.1.601.3.1.1.10.2IpAddressread-onlycurrent
ntpSysPeerOffset
OBJECT-TYPE
This is the system peer offset.
1.3.6.1.4.1.601.3.1.1.10.3DisplayString (SIZE(0..32))read-onlycurrent
peerStaTable
OBJECT-TYPE
This is the peer statistics table.
1.3.6.1.4.1.601.3.1.1.10.4not-accessiblecurrent
peerStaEntry
OBJECT-TYPE
A peer statistics attributes: peerStaIndex Reports index for each peer statistics table. peerStaAddress Reports the peer IP address. peerStaHomeMode Reports the peer NTP mode. peerStaParentMode Reports the parent NTP mode. peerStaLeap Reports leap indicator state. peerStaStratum Reports peer stratum level. peerStaPrecision Reports peer precision. peerStaDelay Reports peer delay. peerStaDispersion Reports peer dispersion. peerStaOffset Reports peer offset. peerStaSentCnt Reports peer sent counter. peerStaProcessCnt Reports peer process counter. peerStaSanity Reports status of peer sanity.
1.3.6.1.4.1.601.3.1.1.10.4.1not-accessiblecurrent
peerStaIndex
OBJECT-TYPE
Reports index for each peer statistics table. This value ranges from 1 to 8.
1.3.6.1.4.1.601.3.1.1.10.4.1.1INTEGER (1..8)not-accessiblecurrent
peerStaAddress
OBJECT-TYPE
Reports the peer IP address.
1.3.6.1.4.1.601.3.1.1.10.4.1.2IpAddressread-onlycurrent
peerStaHomeMode
OBJECT-TYPE
Reports the peer NTP mode. unspect(0), active(1), passive(2), client(3), server(4), broadcast(5), control(6), private(7), bclient(8)
1.3.6.1.4.1.601.3.1.1.10.4.1.3INTEGER {unspect(0), active(1), passive(2), client(3), server(4), broadcast(5), control(6), private(7), bclient(8)}read-onlycurrent
peerStaParentMode
OBJECT-TYPE
Reports the peer parent NTP mode. unspect(0), active(1), passive(2), client(3), server(4), broadcast(5), control(6), private(7), bclient(8)
1.3.6.1.4.1.601.3.1.1.10.4.1.4INTEGER {unspect(0), active(1), passive(2), client(3), server(4), broadcast(5), control(6), private(7), bclient(8)}read-onlycurrent
peerStaLeap
OBJECT-TYPE
Reports leap indicator state. Valid values are: 0 = sync'd, no warning 1 = 1 second will be added 2 = 1 second will be subtracted 3 = not sync'd
1.3.6.1.4.1.601.3.1.1.10.4.1.5INTEGER {nowarning(0), addsec(1), delsec(2), notinsync(3)}read-onlycurrent
peerStaStratum
OBJECT-TYPE
Reports peer stratum level. If zero, it is invalid.
1.3.6.1.4.1.601.3.1.1.10.4.1.6INTEGER (0 | 1..16)read-onlycurrent
peerStaPrecision
OBJECT-TYPE
Reports peer precision.
1.3.6.1.4.1.601.3.1.1.10.4.1.7INTEGER (-1000..1000)read-onlycurrent
peerStaDelay
OBJECT-TYPE
Reports peer delay.
1.3.6.1.4.1.601.3.1.1.10.4.1.8DisplayString (SIZE(0..32))read-onlycurrent
peerStaDispersion
OBJECT-TYPE
Reports peer dispersion.
1.3.6.1.4.1.601.3.1.1.10.4.1.9DisplayString (SIZE(0..32))read-onlycurrent
peerStaOffset
OBJECT-TYPE
Reports peer offset.
1.3.6.1.4.1.601.3.1.1.10.4.1.10DisplayString (SIZE(0..32))read-onlycurrent
peerStaSentCnt
OBJECT-TYPE
Reports peer sent counter.
1.3.6.1.4.1.601.3.1.1.10.4.1.11Counter32read-onlycurrent
peerStaProcessCnt
OBJECT-TYPE
Reports peer process counter.
1.3.6.1.4.1.601.3.1.1.10.4.1.12Counter32read-onlycurrent
peerStaSanity
OBJECT-TYPE
Reports status of peer sanity: 1 = passed 2 = rejected
1.3.6.1.4.1.601.3.1.1.10.4.1.13YesValueread-onlycurrent
ntpTable
OBJECT-TYPE
This table provides the NTP peer statistics.
1.3.6.1.4.1.601.3.1.1.10.5not-accessiblecurrent
ntpEntry
OBJECT-TYPE
NTP peer attributes. ntpIndex Index for each NTP peer entry. ntpPeer Reports NTP peer IP address. ntpPeerType Report NTP peer mode. ntpBrdTimer Report NTP broadcast timer
1.3.6.1.4.1.601.3.1.1.10.5.1not-accessiblecurrent
ntpIndex
OBJECT-TYPE
Index for each NTP peer entry. This value ranges from 1 to 3.
1.3.6.1.4.1.601.3.1.1.10.5.1.1INTEGER (1..3)not-accessiblecurrent
ntpPeer
OBJECT-TYPE
Reports NTP peer IP address. If the ip address is zero for this entry, the whole entry has no meaning.
1.3.6.1.4.1.601.3.1.1.10.5.1.2IpAddressread-onlycurrent
ntpPeerType
OBJECT-TYPE
Report NTP peer mode. CLIENT - The IP for NTP server in client mode. BROADCAST - The subnet mask for broadcasting mode. BCLIENT - The IP for NTP server in broadcast client mode.
1.3.6.1.4.1.601.3.1.1.10.5.1.3INTEGER {client(1), broadcast(2), bclient(3)}read-onlycurrent
ntpBrdTimer
OBJECT-TYPE
Report NTP broadcast timer in notuse(0), t32 (32), t64 (64), t128 (128), t256 (256), t512 (512), t1024 (1024)
1.3.6.1.4.1.601.3.1.1.10.5.1.4INTEGER {notuse(0), t32(32), t64(64), t128(128), t256(256), t512(512), t1024(1024)}read-onlycurrent
ntpAddClient
OBJECT-TYPE
Set NTP peers to enable client mode. This field has meaning only during 'write' operations.
1.3.6.1.4.1.601.3.1.1.10.6IpAddressread-writecurrent
ntpAddBrd
OBJECT-TYPE
Set NTP servers to enable broadcast mode. This field has meaning only during 'write' operations.
1.3.6.1.4.1.601.3.1.1.10.7IpAddressread-writecurrent
ntpAddBclient
OBJECT-TYPE
Set NTP peers to enable broadcast client mode. This field has meaning only during 'write' operations.
1.3.6.1.4.1.601.3.1.1.10.8IpAddressread-writecurrent
ntpDelPeer
OBJECT-TYPE
Delete NTP servers from the peer table. This field has meaning only during 'write' operations.
1.3.6.1.4.1.601.3.1.1.10.9IpAddressread-writecurrent
ntpClr
OBJECT-TYPE
Clear all the NTP peer addresses in the unit. This field has meaning only during 'write' operations.
1.3.6.1.4.1.601.3.1.1.10.10INTEGER {clr(1)}read-writecurrent
ntpBTimer
OBJECT-TYPE
Reports/Set the broadcast timer t32 (32), t64 (64), t128 (128), t256 (256), t512 (512), t1024 (1024)
1.3.6.1.4.1.601.3.1.1.10.11INTEGER {t32(32), t64(64), t128(128), t256(256), t512(512), t1024(1024)}read-writecurrent
ntpPrefer
OBJECT-TYPE
Report/Set the SSU time-of-day source from GPS or NTP Client.
1.3.6.1.4.1.601.3.1.1.10.12INTEGER {gps(1), client(2)}read-writecurrent
time
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.11
tmCurTime
OBJECT-TYPE
Reports the current system time. Note: user can change the system time only when the system is in LOCAL mode. If the system is SERVER or NTP CLIENT, changing system time is not allowed.
1.3.6.1.4.1.601.3.1.1.11.1DateAndTimeread-writecurrent
tmLocalOffset
OBJECT-TYPE
Report/Set local time offset. Note: This allow the users to set a local time offset. The local time offset limits are (+/-)13 hours. This is primarily used in systems with GPS or NTP time-of-day references. where users' prefer system time to be set to local time.
1.3.6.1.4.1.601.3.1.1.11.2TLocalTimeOffsetread-writecurrent
pqlTable
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.12
pqlDs1Table
OBJECT-TYPE
A list of PQL entries. The total entries are 16.
1.3.6.1.4.1.601.3.1.1.12.1not-accessiblecurrent
pqlDs1Entry
OBJECT-TYPE
A PQL entry containing objects of each PQL.
1.3.6.1.4.1.601.3.1.1.12.1.1not-accessiblecurrent
pqlDs1Index
OBJECT-TYPE
A unique value for each PQL table. This value ranges from 1 to 16.
1.3.6.1.4.1.601.3.1.1.12.1.1.1INTEGER (1..16)not-accessiblecurrent
pqlDs1Ssm
OBJECT-TYPE
This DS1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry. Note: If value of this entry is 0xff, the entry is not used. This is the 8-bit value. If the 8th bit is set, this SSM value is not telcom standard. Use caution when modifying as system characteristics will be altered.
1.3.6.1.4.1.601.3.1.1.12.1.1.2TSsmread-writecurrent
pqlDs1Descr
OBJECT-TYPE
Report description for the DS1 Priority Quality Level (PQL) entry.
1.3.6.1.4.1.601.3.1.1.12.1.1.3DisplayString (SIZE(0..14))read-writecurrent
pqlE1Table
OBJECT-TYPE
A list of PQL entries. The total entries are 16.
1.3.6.1.4.1.601.3.1.1.12.2not-accessiblecurrent
pqlE1Entry
OBJECT-TYPE
A PQL entry attributes. pqlE1Index Index value for each PQL table. pqlE1Ssm Report/Set the E1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry. pqlE1Descr Report/Set description for the E1 Priority Quality Level (PQL) entry.
1.3.6.1.4.1.601.3.1.1.12.2.1not-accessiblecurrent
pqlE1Index
OBJECT-TYPE
Index value for each PQL table. This value ranges from 1 to 16.
1.3.6.1.4.1.601.3.1.1.12.2.1.1INTEGER (1..16)not-accessiblecurrent
pqlE1Ssm
OBJECT-TYPE
Report/Set the E1 Sync Status Message (SSM) value for that Priority Quality Level (PQL) entry. Note: If value of this entry is 0xff, this entry is not used. This is the 8-bits value. If the 8th bit is set, this SSM value is not telcom standard. Use caution when modifying as system characteristics will be altered.
1.3.6.1.4.1.601.3.1.1.12.2.1.2TSsmread-writecurrent
pqlE1Descr
OBJECT-TYPE
Report/Set description for the E1 Priority Quality Level (PQL) entry.
1.3.6.1.4.1.601.3.1.1.12.2.1.3DisplayString (SIZE(0..14))read-writecurrent
pqlReset
OBJECT-TYPE
Set DS1/E1 Priority Quality Level(PQL) tables into factory defaults. Note: It only has meaning for 'write' operations.
1.3.6.1.4.1.601.3.1.1.12.3INTEGER {factory(1)}read-writecurrent
ioname
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.13
ionameTable
OBJECT-TYPE
A list of input/output name entries.
1.3.6.1.4.1.601.3.1.1.13.1not-accessiblecurrent
ionEntry
OBJECT-TYPE
An io name entry attributes. ionChassis Identifies which chassis is being addressed. ionSlot Identifies which slot is being addressed. ionPort Identifies which port is being addressed. ionName Report/Set port ioname field.
1.3.6.1.4.1.601.3.1.1.13.1.1not-accessiblecurrent
ionChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.13.1.1.1INTEGER (1..5)not-accessiblecurrent
ionSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.13.1.1.2INTEGER (1..20)not-accessiblecurrent
ionPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.13.1.1.3INTEGER (1..20)not-accessiblecurrent
ionName
OBJECT-TYPE
Report/Set port ioname field. If the name is a null string (zero length), this i/o name s cleared from the port.
1.3.6.1.4.1.601.3.1.1.13.1.1.4DisplayString (SIZE(0..20))read-writecurrent
ionameLoc
OBJECT-TYPE
The text string of the input/output port. The format is defined as xAy-z or xAy-z&&z (if specified the range of ports) where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3, if input) or (1 to 20, if output port). && is the two constant letters '&&', and is port range sepearator z is the ending port number (1 to 3, if input) or (1 to 20, if output port). For example: 1A3-1 means this port located at chassis 1, slot 3, and port 1. 2A5-2&&5 means this ports located at chassis 2, slot 5, and ports 2 thru 5. Note: the user must specify valid port address. The valid port must be physically installed in the system.
1.3.6.1.4.1.601.3.1.1.13.2DisplayString (SIZE(3..20))read-writecurrent
ionameSet
OBJECT-TYPE
Report/Set name associated input/output ports. If the name is a null string, this i/o name is cleared from the ports. Note: You must specify the i/o port range first, and then provide the i/o name.
1.3.6.1.4.1.601.3.1.1.13.3DisplayString (SIZE(0..20))read-writecurrent
comm
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.14
com232Table
OBJECT-TYPE
A list of RS232 port entries. The total entries are 3.
1.3.6.1.4.1.601.3.1.1.14.1not-accessiblecurrent
comEntry
OBJECT-TYPE
An RS232 communication entry attributes. comIndex Index for each communication table. comMode Set the specified RS232 port command parser to ICS or TL1. comEcho Enable/disable echo on the specified RS232 port. comEol Set the specified RS232 port End Of Line (EOL) terminator. comBaud Set the specified RS232 port baud rate.
1.3.6.1.4.1.601.3.1.1.14.1.1not-accessiblecurrent
comIndex
OBJECT-TYPE
Index for each communication table. This value ranges from 1 to 3.
1.3.6.1.4.1.601.3.1.1.14.1.1.1INTEGER (1..3)not-accessiblecurrent
comMode
OBJECT-TYPE
Set the specified RS232 port command parser to ICS or TL1.
1.3.6.1.4.1.601.3.1.1.14.1.1.2INTEGER {ics(1), tl1(2)}read-writecurrent
comEcho
OBJECT-TYPE
Enable/disable echo on the specified RS232 port. Note: This only affects the ICS command mode.
1.3.6.1.4.1.601.3.1.1.14.1.1.3OnValueread-writecurrent
comEol
OBJECT-TYPE
Set the specified RS232 port End Of Line (EOL) terminator. cr (1), lf (2), crlf (3)
1.3.6.1.4.1.601.3.1.1.14.1.1.4INTEGER {cr(1), lf(2), crlf(3)}read-writecurrent
comBaud
OBJECT-TYPE
Set the specified RS232 port baud rate. Valid baud rates are: baud1200 (1200), baud2400 (2400), baud4800 (4800), baud9600 (9600), baud19200 (19200)
1.3.6.1.4.1.601.3.1.1.14.1.1.5INTEGER {baud1200(1200), baud2400(2400), baud4800(4800), baud9600(9600), baud19200(19200)}read-writecurrent
comParmTable
OBJECT-TYPE
A list of communication port setting entries (such as timeout). The total entries are 5.
1.3.6.1.4.1.601.3.1.1.14.2not-accessiblecurrent
comParmEntry
OBJECT-TYPE
Communication setting entry for each logical port. comParmIndex Index for each communication parameter table. comType Specify the communication port. comTimeout Report/Set communication port session timeout (in seconds).
1.3.6.1.4.1.601.3.1.1.14.2.1not-accessiblecurrent
comParmIndex
OBJECT-TYPE
Index for each communication parameter table. This value ranges from 1 to 5.
1.3.6.1.4.1.601.3.1.1.14.2.1.1INTEGER (1..5)not-accessiblecurrent
comType
OBJECT-TYPE
Specify the communication port. Valid values are: 1 = local (RS232) 2 = com A (RS232) 3 = com B (RS232) 4 = telnet 5 = telnet TL1 port
1.3.6.1.4.1.601.3.1.1.14.2.1.2INTEGER {local(1), coma(2), comb(3), telnet(4), etl1(5)}read-onlycurrent
comTimeout
OBJECT-TYPE
Report/Set communication port session timeout (in seconds). Note: 0 = NEVER timeout.
1.3.6.1.4.1.601.3.1.1.14.2.1.3INTEGER (0 | 5..43200)read-writecurrent
comLogoff
OBJECT-TYPE
Logoff user on another logical communication port. The valid communication port are: local (1), coma (2), comb (3), telneta (4), telnetb (5), telnetc (6), telnetd (7), etl1a (8), etl1b (9), etl1c (10), etl1d (11) Note: This field only has meaning for 'write' operations.
1.3.6.1.4.1.601.3.1.1.14.3INTEGER {local(1), coma(2), comb(3), telneta(4), telnetb(5), telnetc(6), telnetd(7), etl1a(8), etl1b(9), etl1c(10), etl1d(11)}read-writecurrent
snmpman
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.15
snmpv2manTable
OBJECT-TYPE
Reports the SNMPv2 manager(s) IP address.
1.3.6.1.4.1.601.3.1.1.15.1not-accessiblecurrent
snmpv2manEntry
OBJECT-TYPE
SNMPv2 manager table attributes. snmpv2manIndex Index for each SNMPv2 manager table entry. snmpv2manIp Set the snmpv2 manager IP address.
1.3.6.1.4.1.601.3.1.1.15.1.1not-accessiblecurrent
snmpv2manIndex
OBJECT-TYPE
Index for each SNMPv2 manager table entry. This value range from 1 to 4.
1.3.6.1.4.1.601.3.1.1.15.1.1.1INTEGER (1..4)not-accessiblecurrent
snmpv2manIp
OBJECT-TYPE
Set the snmpv2 manager IP address. Write a new IP address will put this new IP into table. Write zero IP address will delete this IP address from table. Note: The above only apply to SNMPv2.
1.3.6.1.4.1.601.3.1.1.15.1.1.2IpAddressread-writecurrent
snmpmanInit
OBJECT-TYPE
Initializes the SNMP Manager Table to null IP addresses. Note: This field only has meaning when 'write' operations
1.3.6.1.4.1.601.3.1.1.15.2INTEGER {initv2(1), initv3(2)}read-writecurrent
snmpmanTrap
OBJECT-TYPE
Set the SNMP trap filter to SNMP Manager. The trap filter can be set to be 'alarm' only or all traps. 1 = alarm 2 = all If 'alarm' trap, only events with ID less than 32 (i.e. alarms) will be sent to the SNMP Manager. All other traps will be filtered out. The purpose of this command is to reduce the traffic, if desired.
1.3.6.1.4.1.601.3.1.1.15.3INTEGER {alarm(1), all(2)}read-writecurrent
snmpNotification
OBJECT-TYPE
Set SNMPv3 traps format to use. v2 (1), -- traps in v2 form, address from v2 manager table v3 (2), -- traps in v3 form, address from v2 manager table all(3) -- traps in v2/v3, address from v2/v3 table accordingly It can V2, V3, or both forms. Each v2/v3 traps sent out are viaits own manager table accordingly. Note: The above only apply to SNMPv3 load.
1.3.6.1.4.1.601.3.1.1.15.4INTEGER {v2(1), v3(2), all(3)}read-writecurrent
snmpEnable
OBJECT-TYPE
Activate/deactivate SNMPv2. Note: The above only apply to SNMPv3 load.
1.3.6.1.4.1.601.3.1.1.15.5INTEGER {v2enable(1), v2disable(2)}read-writecurrent
snmpv2userTable
OBJECT-TYPE
SNMPv2 User Table.
1.3.6.1.4.1.601.3.1.1.15.6not-accessiblecurrent
snmpv2userEntry
OBJECT-TYPE
SNMPv2 user table entry attributes. snmpv2userIndex Index for each SNMPv2 user table entry. snmpv2user Reports SNMPv2 user
1.3.6.1.4.1.601.3.1.1.15.6.1not-accessiblecurrent
snmpv2userIndex
OBJECT-TYPE
Index for each SNMPv2 user entry.
1.3.6.1.4.1.601.3.1.1.15.6.1.1INTEGER (1..6)not-accessiblecurrent
snmpv2user
OBJECT-TYPE
Reports SNMPv2 user entry It is the read community string of an SNMPv2 user
1.3.6.1.4.1.601.3.1.1.15.6.1.2DisplayString (SIZE(0..20))read-onlycurrent
snmpv3userTable
OBJECT-TYPE
SNMPv3 User Table.
1.3.6.1.4.1.601.3.1.1.15.7not-accessiblecurrent
snmpv3userEntry
OBJECT-TYPE
SNMPv3 user table entry attributes. snmpv3userIndex Index for each SNMPv3 user table entry. snmpv3user Reports SNMPv3 user
1.3.6.1.4.1.601.3.1.1.15.7.1not-accessiblecurrent
snmpv3userIndex
OBJECT-TYPE
Index for each SNMPv3 user table entry.
1.3.6.1.4.1.601.3.1.1.15.7.1.1INTEGER (1..6)not-accessiblecurrent
snmpv3user
OBJECT-TYPE
Reports SNMPv3 user
1.3.6.1.4.1.601.3.1.1.15.7.1.2DisplayString (SIZE(0..20))read-onlycurrent
snmpv3manTable
OBJECT-TYPE
Reports SNMPv3 manager IP address.
1.3.6.1.4.1.601.3.1.1.15.8not-accessiblecurrent
snmpv3manEntry
OBJECT-TYPE
SNMPv3 manager entry attributes. snmpv3manIndex Index for each SNMPv3 manager entry. snmpv3manIp Report/Set snmpv3 manager IP address. snmpv3manUser Report/Set the SNMPv3 user
1.3.6.1.4.1.601.3.1.1.15.8.1not-accessiblecurrent
snmpv3manIndex
OBJECT-TYPE
Index for each SNMPv3 manager entry. This value range from 1 to 4.
1.3.6.1.4.1.601.3.1.1.15.8.1.1INTEGER (1..4)not-accessiblecurrent
snmpv3manIp
OBJECT-TYPE
Report/Set snmpv3 manager IP address. Note: No action shall be taken at this time. Action shall be taken when the next field 'snmpv3manUser'is written. The above only apply to SNMPv3.
1.3.6.1.4.1.601.3.1.1.15.8.1.2IpAddressread-writecurrent
snmpv3manUser
OBJECT-TYPE
Report/Set the SNMPv3 user Note1: All user names are uppercase except the built-in user. Write username will put this user along with ip into table. Writing a null string will delete this entry from table. Any previouly written IP has no meaning (i.e. the writing the null string of username shall trigger the delete action of that entry from table. Note2: There is no modify action. User need to delete an entry and then add an new entry. Note3: The above only apply to SNMPv3.
1.3.6.1.4.1.601.3.1.1.15.8.1.3DisplayString (SIZE(0..20))read-writecurrent
sys
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.16
sysPbo
OBJECT-TYPE
The input port Phase Built-Out ode (PBO). 1 = EVENT : PBO enabled, PBO sent out, and stored in the event buffer. 2 = REPORT : PBO enabled, PBO sent out, but not stored in the event buffer. 3 = NONE : PBO enabled, but PBO event not sent out. 4 = DISABLE : PBO disabled. Note: This is a system-wide command. When the user writes this field, it will affect all DS1/E1 input modules in the system.
1.3.6.1.4.1.601.3.1.1.16.1INTEGER {event(1), report(2), none(3), disable(4)}read-writecurrent
sysResetClk
OBJECT-TYPE
Reset the specified clock. Restarts clock without maintaining current servo control values.
1.3.6.1.4.1.601.3.1.1.16.2INTEGER {clka(1), clkb(2)}read-writecurrent
sysKeepAliveTable
OBJECT-TYPE
Set system 'keep alive' mode where a trap is generated automatically on a period specified by the customer This is intended to verify the upstream support that the SSU2000 and the associated communication path is functional
1.3.6.1.4.1.601.3.1.1.16.3not-accessiblecurrent
sysAliveEntry
OBJECT-TYPE
System 'keepalive' attributes for TL1 or SNMP. sysAliveIndex Index value for each 'keepalive' table. sysAliveType Keep Alive session type: sysAliveTime Keep alive message interval.
1.3.6.1.4.1.601.3.1.1.16.3.1not-accessiblecurrent
sysAliveIndex
OBJECT-TYPE
Index value for each 'keepalive' table. This range of the value is from 1 to 2.
1.3.6.1.4.1.601.3.1.1.16.3.1.1INTEGER (1..2)not-accessiblecurrent
sysAliveType
OBJECT-TYPE
Keep Alive session type: 1 = TL1 session 2 = SNMP session
1.3.6.1.4.1.601.3.1.1.16.3.1.2INTEGER {tl1(1), snmp(2)}read-onlycurrent
sysAliveTime
OBJECT-TYPE
Keep alive message interval. Valid range = 1 - 60 (minutes). 0 = disabled (default)
1.3.6.1.4.1.601.3.1.1.16.3.1.3INTEGER (0..60)read-writecurrent
sysOpmode
OBJECT-TYPE
Set the operational mode in the SSU-2000. normal(1), -- Non-Subtending subtending(2), -- Domestic Subtending japanese(3) -- Japanese Subtending
1.3.6.1.4.1.601.3.1.1.16.4INTEGER {normal(1), subtending(2), japanese(3)}read-writecurrent
sysTl1Format
OBJECT-TYPE
Set the TL1 format in the SSU-2000. Allows the system to generate GR-831 compliant or GR-833 compliant autonomous events. All SSU-2000 TL1 sessions will generate either GR-831 or GR-833 autonomous events. Refer to TL1 Specification 12613127-001-2 for event formats
1.3.6.1.4.1.601.3.1.1.16.5INTEGER {gr831(1), gr833(2)}read-writecurrent
sysEvtLogin
OBJECT-TYPE
Set LOGIN and LOGOUT events from being stored in the event log. disable(1), -- not store login and logout in the event log enable(2) -- store login and logout in the event log
1.3.6.1.4.1.601.3.1.1.16.6INTEGER {disable(1), enable(2)}read-writecurrent
sysAco
OBJECT-TYPE
Set ACO when writing with active. It has NOP when write with inactive. When read, it returns the current state of ACO.
1.3.6.1.4.1.601.3.1.1.16.7INTEGER {active(1), inactive(2)}read-writecurrent
users
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.17
userTable
OBJECT-TYPE
Report valid user names and their associated user access level. This user list is used for connecting the ICS and TL1 command parser via RS232 or Ethernet port (telnet or TL1 port). Note: the password is not reported.
1.3.6.1.4.1.601.3.1.1.17.1not-accessiblecurrent
userEntry
OBJECT-TYPE
User table attributes: userIndex Index for each user entry. userlevel Reports user access level. username Reports user name.
1.3.6.1.4.1.601.3.1.1.17.1.1not-accessiblecurrent
userIndex
OBJECT-TYPE
Reports index for each user entry. This value ranges from 1 to 25.
1.3.6.1.4.1.601.3.1.1.17.1.1.1INTEGER (1..25)not-accessiblecurrent
userlevel
OBJECT-TYPE
Reports user access level. The user level: (1) USER - Read Only - can retrieve status information only. (2) TECHNICIAN - Read and limited set ability for fault isolating and installation setup of the unit. (3) SUPERVISORY - For configuration modifications. (4) ADMINISTRATOR - Setup or change user access.
1.3.6.1.4.1.601.3.1.1.17.1.1.2INTEGER (1..4)read-onlycurrent
username
OBJECT-TYPE
Reports user name.
1.3.6.1.4.1.601.3.1.1.17.1.1.3DisplayString (SIZE(1..10))read-onlycurrent
who
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.18
whoTable
OBJECT-TYPE
Reports which users are logged into all active communication ports (RS232, TL1, or telnet). It displays the username and the communication port.
1.3.6.1.4.1.601.3.1.1.18.1not-accessiblecurrent
whoEntry
OBJECT-TYPE
Report 'who' table attributes. whoIndex Report index of the 'who' entry. whoPort Report logical communication port. whoName Report user name.
1.3.6.1.4.1.601.3.1.1.18.1.1not-accessiblecurrent
whoIndex
OBJECT-TYPE
Report index of the 'who' entry. This value ranges from 1 to 11.
1.3.6.1.4.1.601.3.1.1.18.1.1.1INTEGER (1..12)not-accessiblecurrent
whoPort
OBJECT-TYPE
Report logical communication port. local(1), -- serial local (craft) port coma(2), -- serial port A comb(3), -- serial port B telneta(4), -- telnet session A telnetb(5), -- telnet session B telnetc(6), -- telnet session C telnetd(7), -- telnet session D etl1a(8), -- TL1 session A etl1b(9), -- TL1 session B etl1c(10), -- TL1 session C etl1d(11) -- TL1 session D
1.3.6.1.4.1.601.3.1.1.18.1.1.2INTEGER {local(1), coma(2), comb(3), telneta(4), telnetb(5), telnetc(6), telnetd(7), etl1a(8), etl1b(9), etl1c(10), etl1d(11)}read-onlycurrent
whoName
OBJECT-TYPE
Report user name.
1.3.6.1.4.1.601.3.1.1.18.1.1.3DisplayString (SIZE(1..10))read-onlycurrent
ntpq
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.19
ntpqXeq
OBJECT-TYPE
Report/Set the PackeTime Module. The format is defined as xAy. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) For example: 1A6 means this PackeTime located at chassis 1, slot 6 Note: the user must specify valid PackeTime address. The valid module must be physically installed in the system. Note: Writing operation causes the system to execute the ntpq. The ntpq returned value may take 2 seconds.
1.3.6.1.4.1.601.3.1.1.19.1DisplayString (SIZE(0..10))read-writecurrent
ntpqTable
OBJECT-TYPE
PackeTime NTPQ entries.
1.3.6.1.4.1.601.3.1.1.19.3not-accessiblecurrent
ntpqEntry
OBJECT-TYPE
Report NTPQ attributes. ntpqChassis Identifies which chassis is being addressed. ntpqSlot Identifies which slot is being addressed. ntpqIndex Identifies which index is being addressed. ntpqValid Reports validity of entry. ntpqPeer Reports address of NTP peer ntpqRefid Reports NTP peer reference ID ntpqStratum Reports NTP peer stratum level ntpqPoll Reports NTP peer poll interval ntpqReach Reports NTP peer reachability ntpqDelay Reports NTP peer delay ntpqOffset Reports NTP peer offset ntpqJitter Report NTP peer jitter
1.3.6.1.4.1.601.3.1.1.19.3.1not-accessiblecurrent
ntpqChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and index number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.19.3.1.1INTEGER (1)not-accessiblecurrent
ntpqSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and index number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.19.3.1.2INTEGER (1..20)not-accessiblecurrent
ntpqIndex
OBJECT-TYPE
Identifies which index is being addressed. This chassis, slot, and index number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.19.3.1.3INTEGER (1..9)not-accessiblecurrent
ntpqValid
OBJECT-TYPE
Reports validity of entry. If this entry is not valid, all info in this entry has no meaning.
1.3.6.1.4.1.601.3.1.1.19.3.1.4ValidValueread-onlycurrent
ntpqPeer
OBJECT-TYPE
Reports address of NTP peer
1.3.6.1.4.1.601.3.1.1.19.3.1.5DisplayString (SIZE(0..20))read-onlycurrent
ntpqRefid
OBJECT-TYPE
Reports NTP system Reference
1.3.6.1.4.1.601.3.1.1.19.3.1.6DisplayString (SIZE(0..20))read-onlycurrent
ntpqStratum
OBJECT-TYPE
Reports NTP server stratum level
1.3.6.1.4.1.601.3.1.1.19.3.1.7INTEGER (0..16)read-onlycurrent
ntpqPoll
OBJECT-TYPE
Reports NTP server poll interval
1.3.6.1.4.1.601.3.1.1.19.3.1.8INTEGER (0..1024)read-onlycurrent
ntpqReach
OBJECT-TYPE
Reports NTP server reachability
1.3.6.1.4.1.601.3.1.1.19.3.1.9DisplayString (SIZE(0..20))read-onlycurrent
ntpqDelay
OBJECT-TYPE
Reports calculated root delay value to primary source
1.3.6.1.4.1.601.3.1.1.19.3.1.10DisplayString (SIZE(0..20))read-onlycurrent
ntpqOffset
OBJECT-TYPE
Reports client's calculated time offset value for the specified server
1.3.6.1.4.1.601.3.1.1.19.3.1.11DisplayString (SIZE(0..20))read-onlycurrent
ntpqJitter
OBJECT-TYPE
Report jitter value
1.3.6.1.4.1.601.3.1.1.19.3.1.12DisplayString (SIZE(0..20))read-onlycurrent
ntpqSyspeer
OBJECT-TYPE
Report syspeer is the IP address of peer selected by server as most likely to provide best timing information.
1.3.6.1.4.1.601.3.1.1.19.4DisplayString (SIZE(0..20))read-onlycurrent
ntpqSysleap
OBJECT-TYPE
Report system leap indicator The NTP server leap indicator (0, +1, -1, or NOSYNC). 2 = NOSYNC
1.3.6.1.4.1.601.3.1.1.19.5INTEGER (-1..2)read-onlycurrent
ntpqSysstratum
OBJECT-TYPE
Report system NTP server stratum level
1.3.6.1.4.1.601.3.1.1.19.6INTEGER (0..16)read-onlycurrent
ntpqSysprecision
OBJECT-TYPE
Report measurement of a number of significant bits in NTP timestamp
1.3.6.1.4.1.601.3.1.1.19.7INTEGER (-100..0)read-onlycurrent
ntpqRootdelay
OBJECT-TYPE
Report calculated root delay value to primary source
1.3.6.1.4.1.601.3.1.1.19.8DisplayString (SIZE(0..20))read-onlycurrent
ntpqRootdispersion
OBJECT-TYPE
Report NTP system Root Dispersion (max error relative to the primary reference source at the root of the synchronization subnet, in seconds)
1.3.6.1.4.1.601.3.1.1.19.9DisplayString (SIZE(0..20))read-onlycurrent
ntpqSysoffset
OBJECT-TYPE
Report clients calculated time offset value for the specified server
1.3.6.1.4.1.601.3.1.1.19.10DisplayString (SIZE(0..20))read-onlycurrent
ntpqReftime
OBJECT-TYPE
Report local reference time
1.3.6.1.4.1.601.3.1.1.19.11DisplayString (SIZE(0..60))read-onlycurrent
route
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.20
rtXeq
OBJECT-TYPE
Write access level: level 1 or above The text string of the PackeTime Module. The format is defined as xAy. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) For example: 1A6 means this PackeTime located at chassis 1, slot 6 Note1: the user must specify valid PackeTime address. The valid module must be physically installed in the system. Note2: Writing operation causes the system to execute the route table. The route table returned value may take 2 seconds.
1.3.6.1.4.1.601.3.1.1.20.1DisplayString (SIZE(0..10))read-writecurrent
routeTable
OBJECT-TYPE
PackeTime route entries.
1.3.6.1.4.1.601.3.1.1.20.3not-accessiblecurrent
rtEntry
OBJECT-TYPE
PackeTime route table attributes: rtChassis Identifies which chassis is being addressed. rtSlot Identifies which slot is being addressed. rtIndex Identifies which index is being addressed. rtValid Reports validity of entry. rtDest Reports destination network/host rtGate Reports destination gateway rtMask Reports destination network mask rtFlags Reports route flags rtMetric Reports the 'distance' to the target (router hops). rtRef Reports number of references to this route. rtUse Report number of lookups for the route. rtIface Report interface associated with this route.
1.3.6.1.4.1.601.3.1.1.20.3.1not-accessiblecurrent
rtChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis, slot, and index number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.20.3.1.1INTEGER (1)not-accessiblecurrent
rtSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis, slot, and index number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.20.3.1.2INTEGER (1..20)not-accessiblecurrent
rtIndex
OBJECT-TYPE
Identifies which index is being addressed. This chassis, slot, and index number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.20.3.1.3INTEGER (1..20)not-accessiblecurrent
rtValid
OBJECT-TYPE
Reports validity of entry. If this entry is not valid, all info in this entry has no meaning.
1.3.6.1.4.1.601.3.1.1.20.3.1.4ValidValueread-onlycurrent
rtDest
OBJECT-TYPE
Reports destination network/host or 0.0.0.0 is default.
1.3.6.1.4.1.601.3.1.1.20.3.1.5IpAddressread-onlycurrent
rtGate
OBJECT-TYPE
Reports gateway address or 0.0.0.0 if none set
1.3.6.1.4.1.601.3.1.1.20.3.1.6IpAddressread-onlycurrent
rtMask
OBJECT-TYPE
Reports netmask for the destination net; '255.255.255.255' for a host destination and '0.0.0.0' for the default route.
1.3.6.1.4.1.601.3.1.1.20.3.1.7IpAddressread-onlycurrent
rtFlags
OBJECT-TYPE
Reports route table flags U (route is up) H (target is a host) G (use gateway) R (reinstate route for dynamic routing) D (dynamically installed by daemon or redirect) M (modified from routing daemon or redirect) A (installed by addrconf) C (cache entry) ! (reject route)
1.3.6.1.4.1.601.3.1.1.20.3.1.8DisplayString (SIZE(0..6))read-onlycurrent
rtMetric
OBJECT-TYPE
Reports the 'distance' to the target (router hops).
1.3.6.1.4.1.601.3.1.1.20.3.1.9INTEGER (0..4)read-onlycurrent
rtRef
OBJECT-TYPE
Reports number of references to this route.
1.3.6.1.4.1.601.3.1.1.20.3.1.10INTEGER (0..4)read-onlycurrent
rtUse
OBJECT-TYPE
Report number of lookups for the route.
1.3.6.1.4.1.601.3.1.1.20.3.1.11INTEGER (0..1)read-onlycurrent
rtIface
OBJECT-TYPE
Report interface associated with this route. 0 = eth0 (Maintenance Port) 1 = eth1 (Service Port A) 2 = eth2 (Service Port B) 3 = bond0 (Service Port Bonding) 10000-14094 = eth1.xxxx 20000-24094 = eth2.xxxx 30000-34094 = bond0.xxxx where xxxx is the VLAN ID.
1.3.6.1.4.1.601.3.1.1.20.3.1.12INTEGER (0..34094)read-onlycurrent
mtie
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.30
mtInpLoc
OBJECT-TYPE
Select input port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. For example: 1A3 means this input port located at chassis 1, slot 3, with all port specified.
1.3.6.1.4.1.601.3.1.1.30.1DisplayString (SIZE(3..10))read-writecurrent
mtFrTime
OBJECT-TYPE
Select starting time to measure the MTIE from. Note: the default time is defined as last 24 hours from current time. The default start-time is the current time minus 24 hours, and the default stop-time is the current time.
1.3.6.1.4.1.601.3.1.1.30.2DateAndTimeread-writecurrent
mtToTime
OBJECT-TYPE
Select the stop-time to measure the MTIE. If the 'year' field of DateAndTime is specified as zero, the default time is used. The default mtToTime is the current time.
1.3.6.1.4.1.601.3.1.1.30.3DateAndTimeread-writecurrent
mtTable
OBJECT-TYPE
Report the MTIE measurement.
1.3.6.1.4.1.601.3.1.1.30.5not-accessiblecurrent
mtEntry
OBJECT-TYPE
A mtie record attributes: mtChassis Identifies which chassis is being addressed. mtSlot Identifies which slot is being addressed. mtPort Identifies which port is being addressed. mtA MTIE record versus clock A. mtB MTIE record versus clock B.
1.3.6.1.4.1.601.3.1.1.30.5.1not-accessiblecurrent
mtChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.30.5.1.1INTEGER (1)not-accessiblecurrent
mtSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.30.5.1.2INTEGER (1..20)not-accessiblecurrent
mtPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.30.5.1.3INTEGER (1..3)not-accessiblecurrent
mtA
OBJECT-TYPE
MTIE record versus clock A. The MTIE record attributes: INTEGER - entry valid ?, 1=valid, 2=invalid DateAndTime - the staring timestamp DateAndTime - the ending timestamp INTEGER - which clock, 1=clka, 2=clkb INTEGER - 0.05 second measurement value INTEGER - 0.1 second measurement value INTEGER - 1 second measurement value INTEGER - 10 second measurement value INTEGER - 100 second measurement value INTEGER - 1000 second measurement value INTEGER - 10000 second measurement value INTEGER - 100000 second measurement value note: if a non-deterministic value is used in this field, a mtie value will be displayed as -1 (i.e. invalid value).
1.3.6.1.4.1.601.3.1.1.30.5.1.4OCTET STRING (SIZE(76))read-onlycurrent
mtB
OBJECT-TYPE
MTIE record versus clock B. The MTIE record attributes: INTEGER - entry valid ?, 1=valid, 2=invalid DateAndTime - the staring timestamp DateAndTime - the ending timestamp INTEGER - which clock, 1=clka, 2=clkb INTEGER - 0.05 second measurement value INTEGER - 0.1 second measurement value INTEGER - 1 second measurement value INTEGER - 10 second measurement value INTEGER - 100 second measurement value INTEGER - 1000 second measurement value INTEGER - 10000 second measurement value INTEGER - 100000 second measurement value note: if a non-deterministic value is used in this field, a mtie value will be displayed as -1 (i.e. invalid value).
1.3.6.1.4.1.601.3.1.1.30.5.1.5OCTET STRING (SIZE(76))read-onlycurrent
mtHisInpLoc
OBJECT-TYPE
Select the input port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. Note: the user must specify valid input port address. The valid port is single port and must be physically installed in the system. Multiple ports are not valid.
1.3.6.1.4.1.601.3.1.1.30.6DisplayString (SIZE(0..10))read-writecurrent
mtHisClk
OBJECT-TYPE
Clock reference used for reporting of MTIE History.
1.3.6.1.4.1.601.3.1.1.30.7INTEGER {clka(1), clkb(2)}read-writecurrent
mtHisCnt
OBJECT-TYPE
Number of days of MTIE History to report. The range = 1 - 100. Default value for this field = 1.
1.3.6.1.4.1.601.3.1.1.30.8INTEGER (1..100)read-writecurrent
mtHisTable
OBJECT-TYPE
A list of mtie history entries. Note: this table is based upon the following values: mtHisInpLoc - the location of the input port mtHisCnt - total number of mtie hostory want to query.
1.3.6.1.4.1.601.3.1.1.30.9not-accessiblecurrent
mtHisEntry
OBJECT-TYPE
MTIE 24-hours history attributes. mtHisChassis Identifies which chassis is being addressed. mtHisSlot Identifies which slot is being addressed. mtHisPort Identifies which port is being addressed. mtHisIndex Index for the MTIE record. mtHisV MTIE record versus selected clock.
1.3.6.1.4.1.601.3.1.1.30.9.1not-accessiblecurrent
mtHisChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.30.9.1.1INTEGER (1)not-accessiblecurrent
mtHisSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.30.9.1.2INTEGER (1..20)not-accessiblecurrent
mtHisPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.30.9.1.3INTEGER (1..3)not-accessiblecurrent
mtHisIndex
OBJECT-TYPE
Index for the MTIE record. Valid range = 1 - 100.
1.3.6.1.4.1.601.3.1.1.30.9.1.4INTEGER (1..100)not-accessiblecurrent
mtHisV
OBJECT-TYPE
MTIE record versus selected clock. The MTIE record attributes: INTEGER - entry valid ?, 1=valid, 2=invalid DateAndTime - the staring timestamp DateAndTime - the ending timestamp INTEGER - which clock, 1=clka, 2=clkb INTEGER - 0.05 second measurement value INTEGER - 0.1 second measurement value INTEGER - 1 second measurement value INTEGER - 10 second measurement value INTEGER - 100 second measurement value INTEGER - 1000 second measurement value INTEGER - 10000 second measurement value INTEGER - 100000 second measurement value note: if a non-deterministic value is used in this field, a mtie value will be displayed as -1 (i.e. invalid value).
1.3.6.1.4.1.601.3.1.1.30.9.1.5OCTET STRING (SIZE(76))read-onlycurrent
tdev
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.31
tdInpLoc
OBJECT-TYPE
Select input port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1. For example: 1A3 means this input port located at hassis 1, slot 3, with all port specified.
1.3.6.1.4.1.601.3.1.1.31.1DisplayString (SIZE(3..10))read-writecurrent
tdFrTime
OBJECT-TYPE
Select starting time to measure the TDEV from. Note: the default time is defined as last 24 hours from current time. The default start-time is the current time minus 24 hours, and the default stop-time is the current time.
1.3.6.1.4.1.601.3.1.1.31.2DateAndTimeread-writecurrent
tdToTime
OBJECT-TYPE
Select stop time to measure the TDEV from. Note: the default time is the current time.
1.3.6.1.4.1.601.3.1.1.31.3DateAndTimeread-writecurrent
tdTable
OBJECT-TYPE
Report the TDEV measurement.
1.3.6.1.4.1.601.3.1.1.31.5not-accessiblecurrent
tdEntry
OBJECT-TYPE
A mtie record attributes: tdChassis Identifies which chassis is being addressed. tdSlot Identifies which slot is being addressed. tdPort Identifies which port is being addressed. tdA TDEV record versus clock A. tdB TDEV record versus clock B.
1.3.6.1.4.1.601.3.1.1.31.5.1not-accessiblecurrent
tdChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.31.5.1.1INTEGER (1)not-accessiblecurrent
tdSlot
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.31.5.1.2INTEGER (1..20)not-accessiblecurrent
tdPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.31.5.1.3INTEGER (1..3)not-accessiblecurrent
tdA
OBJECT-TYPE
TDEV record versus clock A: TDEV record attributes: INTEGER - entry valid ?, 1=valid, 2=invalid DateAndTime - the staring timestamp DateAndTime - the ending timestamp INTEGER - which clock, 1=clka, 2=clkb INTEGER - 0.1 second measurement value INTEGER - 0.3 second measurement value INTEGER - 0.6 second measurement value INTEGER - 1 second measurement value INTEGER - 3 second measurement value INTEGER - 6 second measurement value INTEGER - 10 second measurement value INTEGER - 30 second measurement value INTEGER - 60 second measurement value INTEGER - 100 second measurement value INTEGER - 300 second measurement value INTEGER - 600 second measurement value INTEGER - 1000 second measurement value INTEGER - 3000 second measurement value INTEGER - 6000 second measurement value INTEGER - 10000 second measurement value Note: The value are for the time period, the value provided are multpled by 100 times, to avoid floating number representaion.
1.3.6.1.4.1.601.3.1.1.31.5.1.4OCTET STRING (SIZE(124))read-onlycurrent
tdB
OBJECT-TYPE
TDEV record versus clock B: TDEV record attributes: INTEGER - entry valid ?, 1=valid, 2=invalid DateAndTime - the staring timestamp DateAndTime - the ending timestamp INTEGER - which clock, 1=clka, 2=clkb INTEGER - 0.1 second measurement value INTEGER - 0.3 second measurement value INTEGER - 0.6 second measurement value INTEGER - 1 second measurement value INTEGER - 3 second measurement value INTEGER - 6 second measurement value INTEGER - 10 second measurement value INTEGER - 30 second measurement value INTEGER - 60 second measurement value INTEGER - 100 second measurement value INTEGER - 300 second measurement value INTEGER - 600 second measurement value INTEGER - 1000 second measurement value INTEGER - 3000 second measurement value INTEGER - 6000 second measurement value INTEGER - 10000 second measurement value Note: The value are for the time period, the value provided are multpled by 100 times, to avoid floating number representaion.
1.3.6.1.4.1.601.3.1.1.31.5.1.5OCTET STRING (SIZE(124))read-onlycurrent
tdHisInpLoc
OBJECT-TYPE
Selected input port. The format is defined as xAy-z. where x is the chassis number: in this case is 1, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 3 to 11) - is the constant letter '-', and is slot/port sepearator z is the port number (1 to 3). For example: 1A3-1 means this input port located at chassis 1, slot 3, and port 1 Note: the user must specify valid input port address. The valid port is single port and must be physically installed in the system. Multiple ports are not valid.
1.3.6.1.4.1.601.3.1.1.31.6DisplayString (SIZE(0..10))read-writecurrent
tdHisClk
OBJECT-TYPE
Report/Set which clock is used to make the TDEV measurement.
1.3.6.1.4.1.601.3.1.1.31.7INTEGER {clka(1), clkb(2)}read-writecurrent
tdHisCnt
OBJECT-TYPE
Report/Set the number of days of TDEV History to report. The range = 1 - 100. Default value for this field = 1.
1.3.6.1.4.1.601.3.1.1.31.8INTEGER (1..100)read-writecurrent
tdHisTable
OBJECT-TYPE
A list of tdev history entries. Note: this table is based upon the following values: tdHisInpLoc - the location of the input port tdHisCnt - total number of tdev hostory want to query.
1.3.6.1.4.1.601.3.1.1.31.9not-accessiblecurrent
tdHisEntry
OBJECT-TYPE
TDEV 24-hours history attributes. tdHisChassis Identifies which chassis is being addressed. tdHisSlot Identifies which slot is being addressed. tdHisPort Identifies which port is being addressed. tdHisIndex Index for the TDEV record. tdHisV TDEV record versus selected clock.
1.3.6.1.4.1.601.3.1.1.31.9.1not-accessiblecurrent
tdHisChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.31.9.1.1INTEGER (1)not-accessiblecurrent
tdHisSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.31.9.1.2INTEGER (1..20)not-accessiblecurrent
tdHisPort
OBJECT-TYPE
Identifies which port is being addressed. This chassis number, slot, and port number uniquely identify each inventory entry.
1.3.6.1.4.1.601.3.1.1.31.9.1.3INTEGER (1..3)not-accessiblecurrent
tdHisIndex
OBJECT-TYPE
Index value for the TDEV history record. Valid range = 1 - 100.
1.3.6.1.4.1.601.3.1.1.31.9.1.4INTEGER (1..100)not-accessiblecurrent
tdHisV
OBJECT-TYPE
TDEV record versus selected clock. The TDEV record attributes: INTEGER - entry valid ?, 1=valid, 2=invalid DateAndTime - the staring timestamp DateAndTime - the ending timestamp INTEGER - which clock, 1=clka, 2=clkb INTEGER - 0.1 second measurement value INTEGER - 0.3 second measurement value INTEGER - 0.6 second measurement value INTEGER - 1 second measurement value INTEGER - 3 second measurement value INTEGER - 6 second measurement value INTEGER - 10 second measurement value INTEGER - 30 second measurement value INTEGER - 60 second measurement value INTEGER - 100 second measurement value INTEGER - 300 second measurement value INTEGER - 600 second measurement value INTEGER - 1000 second measurement value INTEGER - 3000 second measurement value INTEGER - 6000 second measurement value INTEGER - 10000 second measurement value Note: The value are for the time period, the value provided are multpled by 100 times, to avoid floating number representaion.
1.3.6.1.4.1.601.3.1.1.31.9.1.5OCTET STRING (SIZE(124))read-onlycurrent
ptpclient
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.36
ptpclientTable
OBJECT-TYPE
Reports PackeTime PTP client list entries. Usage: you need to specify a PTP blade address in ptpclientParmLoc, and then execute the command ptpclientCmdXeq first. The PTP client list will be saved. This ptpclientTable will display all the PTP client list contents of this saved information.
1.3.6.1.4.1.601.3.1.1.36.1not-accessiblecurrent
ptpclientEntry
OBJECT-TYPE
Reports PackeTime PTP client list containing each PTP client status value. ptpclientChassis Identifies which chassis is being addressed. ptpclientSlot Identifies which slot is being addressed. ptpclientData Reports the contents of the Client data TLV:
1.3.6.1.4.1.601.3.1.1.36.1.1not-accessiblecurrent
ptpclientChassis
OBJECT-TYPE
Identifies which chassis is being addressed. This chassis and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.36.1.1.1INTEGER (1..5)not-accessiblecurrent
ptpclientSlot
OBJECT-TYPE
Identifies which slot is being addressed. This chassis and slot number uniquely identify each entry.
1.3.6.1.4.1.601.3.1.1.36.1.1.2INTEGER (1..20)not-accessiblecurrent
ptpclientData
OBJECT-TYPE
Reports the contents of the Client data TLV: INTEGER - mode, 0:dynamic, 1:static INTEGER - ip address OCTET - clock id INTEGER - VLAN ID, if 0xffff, then there is no vlan INTEGER - VLAN Priority INTEGER - Sync Limit (signed value), if 99, the disable INTEGER - Announce Limit (signed value), if 99, the disable INTEGER - Delay Limit (signed value), if 99, the disable
1.3.6.1.4.1.601.3.1.1.36.1.1.3OCTET STRING (SIZE(40))read-onlycurrent
ptpclientParmLoc
OBJECT-TYPE
Set the ports VLAN address. where x is the chassis number: in this case is 1-5, A is the constant letter 'A', and is chassis/slot sepearator. y is the slot number: (range is 1 to 14) For example: 1A6 means this port located at chassis 1, slot 6 Note: the user must specify valid PTP address. The valid port must be physically installed in the system.
1.3.6.1.4.1.601.3.1.1.36.2DisplayString (SIZE(0..10))read-writecurrent
ptpclientCmdXeq
OBJECT-TYPE
Reports the current client list in the module. The max number of client is 400
1.3.6.1.4.1.601.3.1.1.36.3YesValueread-writecurrent
mTrapReq
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.50
tprTag
OBJECT-TYPE
This command is to ask the agent to resend a lost trap. The lost trap is specified by its trap tag number. The trap tag number is a 32-bit positive integer. It will rollover to one, when it reaches the maximum number 2147483647. If the tag number is beyond the agent's abilities to handle, it will respond with an error. Otherwise, the requested trap will be sent to the manager. Note: When resending a trap, the 'tpEvt' field of trap is set to 2 (RE-SEND). In the normal trap, the'tpEvt' field of trap is set to 1 (AUTONOMOUS).
1.3.6.1.4.1.601.3.1.1.50.1INTEGER (1..2147483647)read-writecurrent
mTrapObjs
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.51
tpTag
OBJECT-TYPE
The trap counter which increments for each trap.
1.3.6.1.4.1.601.3.1.1.51.1INTEGER (1..2147483647)read-onlycurrent
tpEvt
OBJECT-TYPE
Indication of whether trap is an autonomous event or resend by user request.
1.3.6.1.4.1.601.3.1.1.51.2INTEGER {autonomous(1), resend(2)}read-onlycurrent
tpId
OBJECT-TYPE
The trap ID number.
1.3.6.1.4.1.601.3.1.1.51.3INTEGER (0..255)read-onlycurrent
tpMCode
OBJECT-TYPE
The trap module hex code (16-bits).
1.3.6.1.4.1.601.3.1.1.51.4TModuleCoderead-onlycurrent
tpTimestamp
OBJECT-TYPE
This DateAndTime string contains the event timestamp.
1.3.6.1.4.1.601.3.1.1.51.5DateAndTimeread-onlycurrent
tpChassis
OBJECT-TYPE
The trap chassis number. In SSU2000, there are some modules have to inserted in the main chassis: COMM, CLOCK, INPUT, GPS modules.
1.3.6.1.4.1.601.3.1.1.51.6INTEGER (1..5)read-onlycurrent
tpSlot
OBJECT-TYPE
The trap slot number. In SSU2000, there are some modules have to inserted in the fixed locations: COMM - 1A2 CLOCK - 1A1 or 1A17 (physical slot address) GPS - 1A3 or 1A5.
1.3.6.1.4.1.601.3.1.1.51.7INTEGER (1..20)read-onlycurrent
tpPort
OBJECT-TYPE
The trap port number. If value 0, it means (DON'T CARE) whole module. In SSU2000, most of the DS1/E1 input module alarms specify the port number (1-3). The remaining modules specify the port number as either '0' or '1'.
1.3.6.1.4.1.601.3.1.1.51.8INTEGER (0..20)read-onlycurrent
tpAlmCode
OBJECT-TYPE
The trap alarm code. Relationship between tpAlmCode and tpNtfCode. For example: If for the set MINOR alarm, the tpAlmCode is MINOR and the tpNtfCode is MINOR. If the MINIR alarm is cleared, the tpAlmCode is MINOR and the tpNtfCode is CLEAR. For all events: The tpAlmCode and tpNtfCode are REPORT.
1.3.6.1.4.1.601.3.1.1.51.9INTEGER {minor(1), major(2), critical(3), ignore(4), report(5)}read-onlycurrent
tpNtfCode
OBJECT-TYPE
The trap alarm notification code. Relationship between tpAlmCode and tpNtfCode. For example for alarms: If for the set MINOR alarm, the tpAlmCode is MINOR and the tpNtfCode is MINOR. If the MINOR alarm is cleared, the tpAlmCode is MINOR and the tpNtfCode is CLEAR. For all events: The tpAlmCode and tpNtfCode are REPORT.
1.3.6.1.4.1.601.3.1.1.51.10INTEGER {minor(1), major(2), critical(3), report(5), clear(6)}read-onlycurrent
tpElevated
OBJECT-TYPE
This alarm if elevated.
1.3.6.1.4.1.601.3.1.1.51.11INTEGER {yes(1), no(2)}read-onlycurrent
tpDescr
OBJECT-TYPE
The text string description of the event.
1.3.6.1.4.1.601.3.1.1.51.12DisplayString (SIZE(0..255))read-onlycurrent
mTraps
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.52
ssuTraps
OBJECT-IDENTITY
The SSU2000 traps
1.3.6.1.4.1.601.3.1.1.52.0current
sInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.601.3.1.1.60
sifNtpNumber
OBJECT-TYPE
0 = if no NTP resource present 1 = if NTP presentt
1.3.6.1.4.1.601.3.1.1.60.1INTEGER (0..1)read-onlycurrent
sifSnmpv2Number
OBJECT-TYPE
0 = if no SNMPv2 resource present (note: it is load resource, not enable/disable) 1 = if SNMPv2 present
1.3.6.1.4.1.601.3.1.1.60.2INTEGER (0..1)read-onlycurrent
sifSnmpv3Number
OBJECT-TYPE
0 = if no SNMPv3 resource present (note: it is load resource, not enable/disable) 1 = if SNMPv3 present
1.3.6.1.4.1.601.3.1.1.60.3INTEGER (0..1)read-onlycurrent
sifClkNumber
OBJECT-TYPE
0 = if no Clock Module present x = number of Clock Modules present
1.3.6.1.4.1.601.3.1.1.60.10INTEGER (0..2)read-onlycurrent
sifGpsNumber
OBJECT-TYPE
0 = if no GPS Module present x = number of GPS Modules present
1.3.6.1.4.1.601.3.1.1.60.11INTEGER (0..2)read-onlycurrent
sifInpDs1Number
OBJECT-TYPE
0 = if no DS1 Input Module present x = number of DS1 Input Modules present
1.3.6.1.4.1.601.3.1.1.60.12INTEGER (0..10)read-onlycurrent
sifInpE1Number
OBJECT-TYPE
0 = if no E1 Input Module present x = number of E1 Input Modules present
1.3.6.1.4.1.601.3.1.1.60.13INTEGER (0..10)read-onlycurrent
sifInpCcNumber
OBJECT-TYPE
0 = if no ANSI CC Input Module present x = number of ANSI CC Input Modules present
1.3.6.1.4.1.601.3.1.1.60.14INTEGER (0..10)read-onlycurrent
sifOutDs1Number
OBJECT-TYPE
0 = if no DS1 Output Module present x = number of DS1 Output Modules present
1.3.6.1.4.1.601.3.1.1.60.15INTEGER (0..100)read-onlycurrent
sifOutE1Number
OBJECT-TYPE
0 = if no E1 Output Module present x = number of E1 Output Modules present
1.3.6.1.4.1.601.3.1.1.60.16INTEGER (0..100)read-onlycurrent
sifOut2048Number
OBJECT-TYPE
0 = if no 2048 Output Module present x = number of 2048 Output Modules present
1.3.6.1.4.1.601.3.1.1.60.17INTEGER (0..100)read-onlycurrent
sifOutCcNumber
OBJECT-TYPE
0 = if no ANSI CC Output Module present x = number of ANSI CC Output Modules present
1.3.6.1.4.1.601.3.1.1.60.18INTEGER (0..100)read-onlycurrent
sifOutE12048Number
OBJECT-TYPE
0 = if no E1/2048KHZ Output Module present x = number of E1/2048KHZ Output Modules present
1.3.6.1.4.1.601.3.1.1.60.19INTEGER (0..100)read-onlycurrent
sifOut422Number
OBJECT-TYPE
0 = if no RS422 Output Module present x = number of RS422 Output Modules present
1.3.6.1.4.1.601.3.1.1.60.20INTEGER (0..100)read-onlycurrent
sifLrmDs1Number
OBJECT-TYPE
0 = if no DS1 LRM Module present x = number of DS1 LRM Modules present
1.3.6.1.4.1.601.3.1.1.60.21INTEGER (0..100)read-onlycurrent
sifOutJsineNumber
OBJECT-TYPE
0 = if no Japanese Sine (J/SW) Output Module present x = number of Sine (J/SW) Output Modules present
1.3.6.1.4.1.601.3.1.1.60.22INTEGER (0..100)read-onlycurrent
sifInpJsineNumber
OBJECT-TYPE
0 = if no Japanese Sine (J/SW) Input Module present x = number of Sine (J/SW) Input Modules present
1.3.6.1.4.1.601.3.1.1.60.23INTEGER (0..10)read-onlycurrent
sifOutJccNumber
OBJECT-TYPE
0 = if no Japanese CC (J/CC) Output Module present x = number of Japanese CC (J/CC) Output Modules present
1.3.6.1.4.1.601.3.1.1.60.24INTEGER (0..100)read-onlycurrent
sifInpJccNumber
OBJECT-TYPE
0 = if no Japanese CC (J/CC) Input Module present x = number of Japanese CC (J/CC) Input Modules present
1.3.6.1.4.1.601.3.1.1.60.25INTEGER (0..10)read-onlycurrent
sifLrmE1Number
OBJECT-TYPE
0 = if no E1 LRM Module present x = number of E1 LRM Modules present
1.3.6.1.4.1.601.3.1.1.60.26INTEGER (0..100)read-onlycurrent

Notifications

NameOIDStatus
ssuEvent
NOTIFICATION-TYPE
SSU2000 trap object which specifies trap tag number, trap id number, module hex code, timestamp, chassis number, slot number, port number, alarm code, alarm notification code, and the text string description.
1.3.6.1.4.1.601.3.1.1.52.0.1current