MIBs Depot

SPC200

Registered at
1.3.6.1.4.1.22764.1
Last updated
2004-12-17 12:30
Organization
Organization
Revisions
2004-12-17 12:30, 2004-11-16 12:30, 2004-09-21 12:00, 2004-09-13 12:00, 2004-07-22 12:00, 2004-07-01 17:57
Namespace
cdata
Source file
SPC200
Digest
sha256:7743c5721f4325455b2b075da14857baf6ef3c9a39c9c1eee67bc63307314e11

Description

Description

Contact

Contact-info

Imports

FromSymbols
IF-MIBifIndex, interfaces
SNMPv2-CONFAGENT-CAPABILITIES, MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue
SPIDCOM-MIBspidcom

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
SPC200
SPIDCOM-MIB

Textual conventions

NameOIDSyntaxAccessStatus
AdaptValue
TEXTUAL-CONVENTION
The adapt level integer value.
current
BandValue
TEXTUAL-CONVENTION
A channel is composed of 7 bands.
current
CarrierValue
TEXTUAL-CONVENTION
A group is composed of 8 carriers.
current
ChannelBandwidthValue
TEXTUAL-CONVENTION
The channel bandwidth integer value.
current
EstimationMode
TEXTUAL-CONVENTION
The type of Channel estimation process. Two are available: - automatic, the equipment negociates the best configuration with the remote equipment, - manual, the operator defines the configuration.
current
GroupValue
TEXTUAL-CONVENTION
A band is composed of 16 groups.
current
ModulationValue
TEXTUAL-CONVENTION
Modulation amplitude used by a group of carriers.
current
PilotValue
TEXTUAL-CONVENTION
The pilot carrier wave can be chosen between the carrier 1 up to carrier 128 inside a band carrier range.
current
PlcChannelType
TEXTUAL-CONVENTION
The different type of plc channels: rx for the current reception channel, rx last for the last reception channel, tx for the current transmission channel.
current
PlcModeType
TEXTUAL-CONVENTION
Type of software management action.
current
ResultValue
TEXTUAL-CONVENTION
Result value of input vectors.
current
SoftwareActionResultValue
TEXTUAL-CONVENTION
Result value of software action process.
current
SoftwareActionType
TEXTUAL-CONVENTION
Type of software management action.
current
SoftwareIndex
TEXTUAL-CONVENTION
The software index.
current

Objects

NameOIDSyntaxAccessStatus
plc
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1
stats
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.1
portStatsTable
OBJECT-TYPE
This table gathers all statistic data specific to SPC200 chip relative to plc connection.
1.3.6.1.4.1.22764.1.1.1.2not-accessiblecurrent
portStatsEntry
OBJECT-TYPE
This row contains statistic data specific to SPC200 chip relative to a connection.
1.3.6.1.4.1.22764.1.1.1.2.1not-accessiblecurrent
portStatsBandIndex
OBJECT-TYPE
The band number on which the signal, noise, ber data are collected.
1.3.6.1.4.1.22764.1.1.1.2.1.1BandValuenot-accessiblecurrent
portStatsGroupIndex
OBJECT-TYPE
The group number on which the signal, noise, ber data are collected
1.3.6.1.4.1.22764.1.1.1.2.1.2GroupValuenot-accessiblecurrent
portStatsCarrierIndex
OBJECT-TYPE
The group number on which the signal, noise, ber data are collected
1.3.6.1.4.1.22764.1.1.1.2.1.3CarrierValuenot-accessiblecurrent
portStatsSignal
OBJECT-TYPE
The DB value of the signal associated with the carrier wave entry.
1.3.6.1.4.1.22764.1.1.1.2.1.4Counter32read-onlycurrent
portStatsNoise
OBJECT-TYPE
The DB value of the noise associated with the carrier wave entry.
1.3.6.1.4.1.22764.1.1.1.2.1.5Counter32read-onlycurrent
portStats2Table
OBJECT-TYPE
This table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in a more compact way. This table has been added to deal with possible slow performances.
1.3.6.1.4.1.22764.1.1.1.3not-accessiblecurrent
portStats2Entry
OBJECT-TYPE
This row contains statistic data specific to SPC200 chip relative to a connection.
1.3.6.1.4.1.22764.1.1.1.3.1not-accessiblecurrent
portStats2Signal
OBJECT-TYPE
The values of the signal for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for each 128 carriers of the considered band.
1.3.6.1.4.1.22764.1.1.1.3.1.1OCTET STRINGread-onlycurrent
portStats2Noise
OBJECT-TYPE
The values of the noise for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for each 128 carriers of the considered band.
1.3.6.1.4.1.22764.1.1.1.3.1.2OCTET STRINGread-onlycurrent
portStats2AvgBandAtt
OBJECT-TYPE
Average attenuation per band (dB).
1.3.6.1.4.1.22764.1.1.1.3.1.3Counter32read-onlycurrent
portStats2AvgBandSNR
OBJECT-TYPE
Average SNR per band (dB).
1.3.6.1.4.1.22764.1.1.1.3.1.4Counter32read-onlycurrent
portStats3Table
OBJECT-TYPE
This table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in a more compact way. This table has been added to deal with possible slow performances.
1.3.6.1.4.1.22764.1.1.1.4not-accessiblecurrent
portStats3Entry
OBJECT-TYPE
This row contains statistic data specific to SPC200 chip relative to a connection.
1.3.6.1.4.1.22764.1.1.1.4.1not-accessiblecurrent
portStats3AvgAtt
OBJECT-TYPE
Average attenuation on the link (dB).
1.3.6.1.4.1.22764.1.1.1.4.1.1Counter32read-onlycurrent
portStats3AvgSNR
OBJECT-TYPE
Average SNR on the link (dB).
1.3.6.1.4.1.22764.1.1.1.4.1.2Counter32read-onlycurrent
bootstats
OBJECT-IDENTITY
boot statistics
1.3.6.1.4.1.22764.1.1.1.5current
bootstatsBoot
OBJECT-TYPE
Boot
1.3.6.1.4.1.22764.1.1.1.5.1Counter32read-onlycurrent
bootstatsManualReset
OBJECT-TYPE
Manual reset
1.3.6.1.4.1.22764.1.1.1.5.2Counter32read-onlycurrent
bootstatsFailureReset
OBJECT-TYPE
Failure reset
1.3.6.1.4.1.22764.1.1.1.5.3Counter32read-onlycurrent
plcObjects
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2
plcMode
OBJECT-TYPE
Plc Mode
1.3.6.1.4.1.22764.1.1.2.1PlcModeTyperead-writecurrent
plcTopo
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.2
plcTopoChanges
OBJECT-TYPE
The total number of topology changes detected by this plc bridge since the management entity was last reset or initialized. Such changes concerns only - the plcBasePortTable rows - the plcBasePortTable columns except for plcBasePortChannelEstimation
1.3.6.1.4.1.22764.1.1.2.2.1Counter32read-onlycurrent
plcBasePortTable
OBJECT-TYPE
This table contains the list of plc remote connection
1.3.6.1.4.1.22764.1.1.2.2.2not-accessiblecurrent
plcBasePortEntry
OBJECT-TYPE
This row contains plc remote connection information
1.3.6.1.4.1.22764.1.1.2.2.2.1not-accessiblecurrent
plcBasePortIndex
OBJECT-TYPE
The MAC address of the MAC layer above the plc interface of the remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.2.1.1MacAddressnot-accessiblecurrent
plcBasePortAddress
OBJECT-TYPE
The MAC address of the MAC layer above the plc interface of the remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.2.1.2MacAddressread-onlycurrent
plcBasePortChannelEstimation
OBJECT-TYPE
Enable or disable the automatic channel estimation processus.
1.3.6.1.4.1.22764.1.1.2.2.2.1.3EstimationModeread-writecurrent
plcBasePortAttenuation
OBJECT-TYPE
Link attenuation (dB).
1.3.6.1.4.1.22764.1.1.2.2.2.1.4Counter32read-onlycurrent
plcChannelModulationStringTable
OBJECT-TYPE
This table contains string values for a quick access to the modulation amplitude configurations of all active channels.
1.3.6.1.4.1.22764.1.1.2.2.3not-accessiblecurrent
plcChannelModulationStringEntry
OBJECT-TYPE
This row contains string values for a quick access to the modulation amplitude configuration of each active channel of the remote connection referenced by plcBasePortIndex.
1.3.6.1.4.1.22764.1.1.2.2.3.1not-accessiblecurrent
plcRxChannelModulation
OBJECT-TYPE
The modulation amplitude values for the Rx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits. There are ( 16 groups * 7 bands ) / 2 = 66 values.
1.3.6.1.4.1.22764.1.1.2.2.3.1.1OCTET STRINGread-onlycurrent
plcRxLastChannelModulation
OBJECT-TYPE
The modulation amplitude values for the Rx Last channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits representing ModulationValue - 1. There are ( 16 groups * 7 bands ) / 2 = 66 values.
1.3.6.1.4.1.22764.1.1.2.2.3.1.2OCTET STRINGread-onlycurrent
plcTxChannelModulation
OBJECT-TYPE
The modulation amplitude values for the Tx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits. There are ( 16 groups * 7 bands ) / 2 = 66 values.
1.3.6.1.4.1.22764.1.1.2.2.3.1.3OCTET STRINGread-onlycurrent
plcChannelModulationTable
OBJECT-TYPE
This table contains the modulation amplitude configuration of all active channels.
1.3.6.1.4.1.22764.1.1.2.2.4not-accessiblecurrent
plcChannelModulationEntry
OBJECT-TYPE
This row contains modulation amplitude configuration of the channel, referenced by the plcPortChannelIndex, of the remote connection referenced by plcBasePortIndex.
1.3.6.1.4.1.22764.1.1.2.2.4.1not-accessiblecurrent
plcModBandIndex
OBJECT-TYPE
The band number of which the modulations are defined
1.3.6.1.4.1.22764.1.1.2.2.4.1.1BandValuenot-accessiblecurrent
plcModGroup1
OBJECT-TYPE
The modulation amplitude of the first group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.2ModulationValueread-onlycurrent
plcModGroup2
OBJECT-TYPE
The modulation amplitude of the second group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.3ModulationValueread-onlycurrent
plcModGroup3
OBJECT-TYPE
The modulation amplitude of the third group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.4ModulationValueread-onlycurrent
plcModGroup4
OBJECT-TYPE
The modulation amplitude of the fourth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.5ModulationValueread-onlycurrent
plcModGroup5
OBJECT-TYPE
The modulation amplitude of the fifth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.6ModulationValueread-onlycurrent
plcModGroup6
OBJECT-TYPE
The modulation amplitude of the sixth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.7ModulationValueread-onlycurrent
plcModGroup7
OBJECT-TYPE
The modulation amplitude of the seventh group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.8ModulationValueread-onlycurrent
plcModGroup8
OBJECT-TYPE
The modulation amplitude of the eighth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.9ModulationValueread-onlycurrent
plcModGroup9
OBJECT-TYPE
The modulation amplitude of the nineth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.10ModulationValueread-onlycurrent
plcModGroup10
OBJECT-TYPE
The modulation amplitude of the tenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.11ModulationValueread-onlycurrent
plcModGroup11
OBJECT-TYPE
The modulation amplitude of the eleventh group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.12ModulationValueread-onlycurrent
plcModGroup12
OBJECT-TYPE
The modulation amplitude of the twelveth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.13ModulationValueread-onlycurrent
plcModGroup13
OBJECT-TYPE
The modulation amplitude of the thirteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.14ModulationValueread-onlycurrent
plcModGroup14
OBJECT-TYPE
The modulation amplitude of the fourteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.15ModulationValueread-onlycurrent
plcModGroup15
OBJECT-TYPE
The modulation amplitude of the fifteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.16ModulationValueread-onlycurrent
plcModGroup16
OBJECT-TYPE
The modulation amplitude of the sixteenth group of the band entry of the channel entry for a given remote connection entry.
1.3.6.1.4.1.22764.1.1.2.2.4.1.17ModulationValueread-onlycurrent
plcChannelModulationInput
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.2.5
plcModulationInputAddr
OBJECT-TYPE
The MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the modulation value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.5.1MacAddressread-writecurrent
plcModulationInputChannel
OBJECT-TYPE
The channel type of the remote PLC equipment for which the modulation value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.5.2PlcChannelTyperead-writecurrent
plcModulationInputBand
OBJECT-TYPE
The band number of which the modulation value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.5.3BandValueread-writecurrent
plcInputModulationGroup1
OBJECT-TYPE
The new requested modulation amplitude of the first group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.4ModulationValueread-writecurrent
plcInputModulationGroup2
OBJECT-TYPE
The new requested modulation amplitude of the second group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.5ModulationValueread-writecurrent
plcInputModulationGroup3
OBJECT-TYPE
The new requested modulation amplitude of the third group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.6ModulationValueread-writecurrent
plcInputModulationGroup4
OBJECT-TYPE
The new requested modulation amplitude of the fourth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.7ModulationValueread-writecurrent
plcInputModulationGroup5
OBJECT-TYPE
The new requested modulation amplitude of the fifth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.8ModulationValueread-writecurrent
plcInputModulationGroup6
OBJECT-TYPE
The new requested modulation amplitude of the sixth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.9ModulationValueread-writecurrent
plcInputModulationGroup7
OBJECT-TYPE
The new requested modulation amplitude of the seventh group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.10ModulationValueread-writecurrent
plcInputModulationGroup8
OBJECT-TYPE
The new requested modulation amplitude of the eighth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.11ModulationValueread-writecurrent
plcInputModulationGroup9
OBJECT-TYPE
The new requested modulation amplitude of the nineth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.12ModulationValueread-writecurrent
plcInputModulationGroup10
OBJECT-TYPE
The new requested modulation amplitude of the tenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.13ModulationValueread-writecurrent
plcInputModulationGroup11
OBJECT-TYPE
The new requested modulation amplitude of the eleventh group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.14ModulationValueread-writecurrent
plcInputModulationGroup12
OBJECT-TYPE
The new requested modulation amplitude of the twelveth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.15ModulationValueread-writecurrent
plcInputModulationGroup13
OBJECT-TYPE
The new requested modulation amplitude of the thirteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.16ModulationValueread-writecurrent
plcInputModulationGroup14
OBJECT-TYPE
The new requested modulation amplitude of the fourteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.17ModulationValueread-writecurrent
plcInputModulationGroup15
OBJECT-TYPE
The new requested modulation amplitude of the fifteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.18ModulationValueread-writecurrent
plcInputModulationGroup16
OBJECT-TYPE
The new requested modulation amplitude of the sixteenth group of the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.5.19ModulationValueread-writecurrent
plcModulationInputProceed
OBJECT-TYPE
True to request a modification of all the modulations associated to a band and a channel of a remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.5.20TruthValueread-writecurrent
plcModulationInputResult
OBJECT-TYPE
Result value of the requested modulation value changes.
1.3.6.1.4.1.22764.1.1.2.2.5.21ResultValueread-onlycurrent
plcPortChannelTable
OBJECT-TYPE
This table contains the list of plc channels
1.3.6.1.4.1.22764.1.1.2.2.6not-accessiblecurrent
plcPortChannelEntry
OBJECT-TYPE
This row contains plc channel information
1.3.6.1.4.1.22764.1.1.2.2.6.1not-accessiblecurrent
plcPortChannelIndex
OBJECT-TYPE
The channel number belongs to the remote connection with plc equipment associated with the plcBasePortIndex value. Only three channels are expected. Index 1 for RX channel Index 2 for RXLast channel index 3 for TX channel
1.3.6.1.4.1.22764.1.1.2.2.6.1.1Unsigned32not-accessiblecurrent
plcPortChannelType
OBJECT-TYPE
The channel type.
1.3.6.1.4.1.22764.1.1.2.2.6.1.2PlcChannelTyperead-onlycurrent
plcPortChannelGain
OBJECT-TYPE
The gain associated with the channel.
1.3.6.1.4.1.22764.1.1.2.2.6.1.3Integer32read-writecurrent
plcPortChannelBandwidth
OBJECT-TYPE
The bandwidth of the channel in Kbit/s.
1.3.6.1.4.1.22764.1.1.2.2.6.1.4ChannelBandwidthValueread-onlycurrent
plcPortChannelMaxBandwidth
OBJECT-TYPE
The maximum bandwidth of the channel in Kbit/s.
1.3.6.1.4.1.22764.1.1.2.2.6.1.5ChannelBandwidthValueread-onlycurrent
plcPortChannelSynchronizationBand
OBJECT-TYPE
The synchronization band used for this channel.
1.3.6.1.4.1.22764.1.1.2.2.6.1.6BandValueread-onlycurrent
plcChannelPilotStringTable
OBJECT-TYPE
This table contains the string values representing of pilot values of all active channels.
1.3.6.1.4.1.22764.1.1.2.2.7not-accessiblecurrent
plcChannelPilotStringEntry
OBJECT-TYPE
This row contains a quick access for pilot values , of the remote connection referenced by plcBasePortIndex.
1.3.6.1.4.1.22764.1.1.2.2.7.1not-accessiblecurrent
plcRxChannelPilots
OBJECT-TYPE
The carrier wave numbers which support the pilot waves for the Rx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
1.3.6.1.4.1.22764.1.1.2.2.7.1.1OCTET STRINGread-onlycurrent
plcRxLastChannelPilots
OBJECT-TYPE
The carrier wave numbers which support the pilot waves for the Rx Last Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
1.3.6.1.4.1.22764.1.1.2.2.7.1.2OCTET STRINGread-onlycurrent
plcTxChannelPilots
OBJECT-TYPE
The carrier wave numbers which support the pilot waves for the Tx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
1.3.6.1.4.1.22764.1.1.2.2.7.1.3OCTET STRINGread-onlycurrent
plcChannelPilotsTable
OBJECT-TYPE
This tabel contains pilots configuration for each plc channel.
1.3.6.1.4.1.22764.1.1.2.2.8not-accessiblecurrent
plcChannelPilotsEntry
OBJECT-TYPE
This row contains the pilots 1 and 2 configuration for a channel defined by the couple (plcBasePortIndex, plcPortChannelIndex)
1.3.6.1.4.1.22764.1.1.2.2.8.1not-accessiblecurrent
plcChannelPilotBandIndex
OBJECT-TYPE
The band number on which the pilots are defined.
1.3.6.1.4.1.22764.1.1.2.2.8.1.1BandValuenot-accessiblecurrent
plcChannelPilot1
OBJECT-TYPE
The carrier wave number which supports the first pilot wave for the channel associated with this entry.
1.3.6.1.4.1.22764.1.1.2.2.8.1.2PilotValueread-onlycurrent
plcChannePilot2
OBJECT-TYPE
The carrier wave number which supports the second pilot wave for the channel associated with this entry.
1.3.6.1.4.1.22764.1.1.2.2.8.1.3PilotValueread-onlycurrent
plcChannelPilotsInput
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.2.9
plcPilotsInputAddr
OBJECT-TYPE
The MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the pilot value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.9.1MacAddressread-writecurrent
plcPilotsInputChannel
OBJECT-TYPE
The channel type of the remote PLC equipment for which the pilot value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.9.2PlcChannelTyperead-writecurrent
plcPilotsInputBand
OBJECT-TYPE
The band number of which the pilots value changes are requested.
1.3.6.1.4.1.22764.1.1.2.2.9.3BandValueread-writecurrent
plcInputChannelPilot1
OBJECT-TYPE
The carrier wave number which supports the first pilot wave for the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.9.4PilotValueread-writecurrent
plcInputChannelPilot2
OBJECT-TYPE
The carrier wave number which supports the second pilot wave for the considered band and channel input values.
1.3.6.1.4.1.22764.1.1.2.2.9.5PilotValueread-writecurrent
plcPilotsInputProceed
OBJECT-TYPE
True to request a modification of the first and second pilot associated to a band and a channel of a remote PLC equipment.
1.3.6.1.4.1.22764.1.1.2.2.9.6TruthValueread-writecurrent
plcPilotsInputResult
OBJECT-TYPE
Result value of the requested pilot values changes.
1.3.6.1.4.1.22764.1.1.2.2.9.7ResultValueread-onlycurrent
plcNodeConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3
plcNodeNotches
OBJECT-TYPE
The values of the notches for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing the 8 notches of each group. There is one value for each 7 * 16 bands.
1.3.6.1.4.1.22764.1.1.2.3.1OCTET STRINGread-onlycurrent
plcNodeNotchesTable
OBJECT-TYPE
This table contains Notches configuration for the SPC200 chip.
1.3.6.1.4.1.22764.1.1.2.3.2not-accessiblecurrent
plcNodeNotchesEntry
OBJECT-TYPE
This row contains Notches configuration for a group. The group is defined by the couple (plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex).
1.3.6.1.4.1.22764.1.1.2.3.2.1not-accessiblecurrent
plcNodeNotchesBandIndex
OBJECT-TYPE
The band number on which the notches are defined.
1.3.6.1.4.1.22764.1.1.2.3.2.1.1BandValuenot-accessiblecurrent
plcNodeNotchesGroupIndex
OBJECT-TYPE
The group number on which the notches are defined.
1.3.6.1.4.1.22764.1.1.2.3.2.1.2GroupValuenot-accessiblecurrent
plcNodeNotchesCarrier1
OBJECT-TYPE
Tell if the first carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.3TruthValueread-onlycurrent
plcNodeNotchesCarrier2
OBJECT-TYPE
Tell if the second carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.4TruthValueread-onlycurrent
plcNodeNotchesCarrier3
OBJECT-TYPE
Tell if the third carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.5TruthValueread-onlycurrent
plcNodeNotchesCarrier4
OBJECT-TYPE
Tell if the fourth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.6TruthValueread-onlycurrent
plcNodeNotchesCarrier5
OBJECT-TYPE
Tell if the fifth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.7TruthValueread-onlycurrent
plcNodeNotchesCarrier6
OBJECT-TYPE
Tell if the sixth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.8TruthValueread-onlycurrent
plcNodeNotchesCarrier7
OBJECT-TYPE
Tell if the seventh carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.9TruthValueread-onlycurrent
plcNodeNotchesCarrier8
OBJECT-TYPE
Tell if the eighth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.2.1.10TruthValueread-onlycurrent
plcNodeNotchesInput
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.3
plcNodeNotchesInputBand
OBJECT-TYPE
The band number on which the notches value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.3.1BandValueread-writecurrent
plcNodeNotchesInputGroup
OBJECT-TYPE
The group number on which the notches value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.3.2GroupValueread-writecurrent
plcNodeNotchesInputCarrier1
OBJECT-TYPE
The first carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.3TruthValueread-writecurrent
plcNodeNotchesInputCarrier2
OBJECT-TYPE
The second carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.4TruthValueread-writecurrent
plcNodeNotchesInputCarrier3
OBJECT-TYPE
The third carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.5TruthValueread-writecurrent
plcNodeNotchesInputCarrier4
OBJECT-TYPE
The fourth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.6TruthValueread-writecurrent
plcNodeNotchesInputCarrier5
OBJECT-TYPE
The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.7TruthValueread-writecurrent
plcNodeNotchesInputCarrier6
OBJECT-TYPE
The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.8TruthValueread-writecurrent
plcNodeNotchesInputCarrier7
OBJECT-TYPE
The seventh carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.9TruthValueread-writecurrent
plcNodeNotchesInputCarrier8
OBJECT-TYPE
The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch.
1.3.6.1.4.1.22764.1.1.2.3.3.10TruthValueread-writecurrent
plcNodeNotchesInputProceed
OBJECT-TYPE
True to request a modification of the carrier notches associated to the considered group and band.
1.3.6.1.4.1.22764.1.1.2.3.3.11TruthValueread-writecurrent
plcNodeNotchesInputResult
OBJECT-TYPE
Result value of the requested node carrier notches value changes.
1.3.6.1.4.1.22764.1.1.2.3.3.12ResultValueread-onlycurrent
plcNodePilots
OBJECT-TYPE
The values of the pilot for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands.
1.3.6.1.4.1.22764.1.1.2.3.4OCTET STRINGread-onlycurrent
plcNodePilotsTable
OBJECT-TYPE
This table contains pilot values used by default on all channels.
1.3.6.1.4.1.22764.1.1.2.3.5not-accessiblecurrent
plcNodePilotsEntry
OBJECT-TYPE
This row contains pilot values used by default on a band. The band is defined by the index plcNodePilotsBandIndex.
1.3.6.1.4.1.22764.1.1.2.3.5.1not-accessiblecurrent
plcNodePilotsBandIndex
OBJECT-TYPE
The band number on which the pilot values are defined.
1.3.6.1.4.1.22764.1.1.2.3.5.1.1BandValuenot-accessiblecurrent
plcNodePilot1
OBJECT-TYPE
The default carrier wave number which supports the first pilot wave.
1.3.6.1.4.1.22764.1.1.2.3.5.1.2PilotValueread-onlycurrent
plcNodePilot2
OBJECT-TYPE
The default carrier wave number which supports the second pilot wave.
1.3.6.1.4.1.22764.1.1.2.3.5.1.3PilotValueread-onlycurrent
plcNodePilotsInput
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.6
plcNodePilotsInputBand
OBJECT-TYPE
The band number on which the pilot values changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.6.1BandValueread-writecurrent
plcInputNodePilot1
OBJECT-TYPE
The default carrier wave number which supports the first pilot wave of the considered band.
1.3.6.1.4.1.22764.1.1.2.3.6.2PilotValueread-writecurrent
plcInputNodePilot2
OBJECT-TYPE
The default carrier wave number which supports the second pilot wave of the considered band.
1.3.6.1.4.1.22764.1.1.2.3.6.3PilotValueread-writecurrent
plcNodePilotsInputProceed
OBJECT-TYPE
True to request a modification of the pilot values associated to the considered band.
1.3.6.1.4.1.22764.1.1.2.3.6.4TruthValueread-writecurrent
plcNodePilotsInputResult
OBJECT-TYPE
Result value of the requested node pilot values changes.
1.3.6.1.4.1.22764.1.1.2.3.6.5ResultValueread-onlycurrent
plcNodeAdaptsStringTable
OBJECT-TYPE
This table contains string values for a quick access to the adapt configurations of all the carriers.
1.3.6.1.4.1.22764.1.1.2.3.7not-accessiblecurrent
plcNodeAdaptsStringEntry
OBJECT-TYPE
This row contains string values for a quick access to the adapt configuration of each carrier of a band.
1.3.6.1.4.1.22764.1.1.2.3.7.1not-accessiblecurrent
plcNodeAdaptsStringBandIndex
OBJECT-TYPE
The band number on which the adapt values are defined.
1.3.6.1.4.1.22764.1.1.2.3.7.1.1BandValuenot-accessiblecurrent
plcNodeAdaptsStringBand
OBJECT-TYPE
The adapt values of the 128 carriers of a band. The expected format is VALUE VALUE VALUE ... VALUE. Each value is two octets representing one adapt carrier level. There are ( 16 groups * 8 carriers) = 128 values.
1.3.6.1.4.1.22764.1.1.2.3.7.1.2OCTET STRINGread-onlycurrent
plcNodeAdaptsTable
OBJECT-TYPE
This table contains adapt level configuration for each carrier of the node.
1.3.6.1.4.1.22764.1.1.2.3.8not-accessiblecurrent
plcNodeAdaptsEntry
OBJECT-TYPE
This row contains adapt level values for a group of carriers. The group is defined by the couple (plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex).
1.3.6.1.4.1.22764.1.1.2.3.8.1not-accessiblecurrent
plcNodeAdaptsBandIndex
OBJECT-TYPE
The band number on which the adapt values are defined.
1.3.6.1.4.1.22764.1.1.2.3.8.1.1BandValuenot-accessiblecurrent
plcNodeAdaptsGroupIndex
OBJECT-TYPE
The group number on which the adapt values are defined.
1.3.6.1.4.1.22764.1.1.2.3.8.1.2GroupValuenot-accessiblecurrent
plcNodeAdaptsCarrier1
OBJECT-TYPE
The adapt level of the first carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.3AdaptValueread-onlycurrent
plcNodeAdaptsCarrier2
OBJECT-TYPE
The adapt level of the second carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.4AdaptValueread-onlycurrent
plcNodeAdaptsCarrier3
OBJECT-TYPE
The adapt level of the third carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.5AdaptValueread-onlycurrent
plcNodeAdaptsCarrier4
OBJECT-TYPE
The adapt level of the fourth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.6AdaptValueread-onlycurrent
plcNodeAdaptsCarrier5
OBJECT-TYPE
The adapt level of the fifth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.7AdaptValueread-onlycurrent
plcNodeAdaptsCarrier6
OBJECT-TYPE
The adapt level of the sixth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.8AdaptValueread-onlycurrent
plcNodeAdaptsCarrier7
OBJECT-TYPE
The adapt level of the seventh carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.9AdaptValueread-onlycurrent
plcNodeAdaptsCarrier8
OBJECT-TYPE
The adapt level of the eighth carrier of the group.
1.3.6.1.4.1.22764.1.1.2.3.8.1.10AdaptValueread-onlycurrent
plcNodeAdaptsInput
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.9
plcNodeAdaptsInputBand
OBJECT-TYPE
The band number on which the adapt level value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.9.1BandValueread-writecurrent
plcNodeAdaptsInputGroup
OBJECT-TYPE
The group number on which the adapt level value changes are requested.
1.3.6.1.4.1.22764.1.1.2.3.9.2GroupValueread-writecurrent
plcNodeAdaptsInputCarrier1
OBJECT-TYPE
The adapt level of the first carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.3AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier2
OBJECT-TYPE
The adapt level of the second carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.4AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier3
OBJECT-TYPE
The adapt level of the third carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.5AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier4
OBJECT-TYPE
The adapt level of the fourth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.6AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier5
OBJECT-TYPE
The adapt level of the fifth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.7AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier6
OBJECT-TYPE
The adapt level of the sixth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.8AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier7
OBJECT-TYPE
The adapt level of the seventh carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.9AdaptValueread-writecurrent
plcNodeAdaptsInputCarrier8
OBJECT-TYPE
The adapt level of the eighth carrier of the considered group of the chosen band.
1.3.6.1.4.1.22764.1.1.2.3.9.10AdaptValueread-writecurrent
plcNodeAdaptsInputProceed
OBJECT-TYPE
True to request a modification of the carrier adapt level associated to the considered group and band.
1.3.6.1.4.1.22764.1.1.2.3.9.11TruthValueread-writecurrent
plcNodeAdaptsInputResult
OBJECT-TYPE
Result value of the requested node adapt level value changes.
1.3.6.1.4.1.22764.1.1.2.3.9.12ResultValueread-onlycurrent
plcNodeNetConfigTable
OBJECT-TYPE
This table contains ip and mac addresses of the node.
1.3.6.1.4.1.22764.1.1.2.3.10not-accessiblecurrent
plcNodeNetConfigEntry
OBJECT-TYPE
This row contains ip and mac address used by an interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1not-accessiblecurrent
plcNodeIpAddr
OBJECT-TYPE
The IP address of the IP layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.1IpAddressread-writecurrent
plcNodeNetMask
OBJECT-TYPE
The IP Subnet mask of the IP layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.2IpAddressread-writecurrent
plcNodeMacAddr
OBJECT-TYPE
The MAC address of the MAC layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.3MacAddressread-writecurrent
plcNodeGateway
OBJECT-TYPE
The Gateway address of the IP layer above the interface.
1.3.6.1.4.1.22764.1.1.2.3.10.1.4IpAddressread-writecurrent
plcNodeActions
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.11
plcNodeActionsCommit
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.11.1
plcNodeActionsCommitProceed
OBJECT-TYPE
True to request the commit of the configuration changes into the flash memory
1.3.6.1.4.1.22764.1.1.2.3.11.1.1TruthValueread-writecurrent
plcNodeActionsCommitResult
OBJECT-TYPE
Result value of the requested flash commit operation.
1.3.6.1.4.1.22764.1.1.2.3.11.1.2ResultValueread-onlycurrent
plcNodeActionsReset
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.11.2
plcNodeActionsResetProceed
OBJECT-TYPE
True to request the reset of the node. This operation will terminate the communication between the manager and the node
1.3.6.1.4.1.22764.1.1.2.3.11.2.1TruthValueread-writecurrent
plcNodeActionsCarrier
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.3.11.3
plcNodeActionsCarrierFlatProceed
OBJECT-TYPE
True to request the equipment to flat the signal
1.3.6.1.4.1.22764.1.1.2.3.11.3.1TruthValueread-writecurrent
plcSNAnalyser
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.4
plcSNAnalyserEnable
OBJECT-TYPE
true if the modem should turn to spectrum analyser mode. In this mode the modem enters a receive only mode, and captures periodic samples of the signal on the powerline. The spectrum analyser mode shall be disabled for normal powerline modem operation.
1.3.6.1.4.1.22764.1.1.2.4.1INTEGER {true(1), false(2)}read-writecurrent
plcSNAnalyserTable
OBJECT-TYPE
This table gathers all statistic data specific to SPC200 chip relative to plc analyser.
1.3.6.1.4.1.22764.1.1.2.4.2not-accessiblecurrent
plcSNAnalyserEntry
OBJECT-TYPE
This row contains statistic data specific to SPC200 chip relative to a band.
1.3.6.1.4.1.22764.1.1.2.4.2.1not-accessiblecurrent
plcSNAnalyserMinSignal
OBJECT-TYPE
Minimum signal measured over several samples for the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113
1.3.6.1.4.1.22764.1.1.2.4.2.1.1OCTET STRINGread-onlycurrent
plcSNAnalyserMaxSignal
OBJECT-TYPE
Maximum signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113
1.3.6.1.4.1.22764.1.1.2.4.2.1.2OCTET STRINGread-onlycurrent
plcSNAnalyserAvgSignal
OBJECT-TYPE
Average signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113
1.3.6.1.4.1.22764.1.1.2.4.2.1.3OCTET STRINGread-onlycurrent
plcSNAnalyserLastSignal
OBJECT-TYPE
Signal measured for last sample on the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113
1.3.6.1.4.1.22764.1.1.2.4.2.1.4OCTET STRINGread-onlycurrent
plcSNAnalyserFFTDiv
OBJECT-TYPE
FFT division factor on the associated band.
1.3.6.1.4.1.22764.1.1.2.4.2.1.5Counter32read-onlycurrent
plcSNAnalyserAGC
OBJECT-TYPE
Gain factor in dB, as used by the Automatic Gain Control last sample
1.3.6.1.4.1.22764.1.1.2.4.3Integer32 (0..255)read-onlycurrent
plcAGCAnalyser
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.5
plcAGCAnalyserEnable
OBJECT-TYPE
1.3.6.1.4.1.22764.1.1.2.5.1INTEGER {true(1), false(2)}read-writecurrent
plcAGCAnalyserSamplesPart1
OBJECT-TYPE
1.3.6.1.4.1.22764.1.1.2.5.2OCTET STRINGread-onlycurrent
plcAGCAnalyserSamplesPart2
OBJECT-TYPE
1.3.6.1.4.1.22764.1.1.2.5.3OCTET STRINGread-onlycurrent
plcBssId
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.6
plcMasterBssId
OBJECT-TYPE
The value of the master Bss Id
1.3.6.1.4.1.22764.1.1.2.6.1INTEGER (0..99)read-writecurrent
plcSlaveBssId
OBJECT-TYPE
The value of the slave Bss Id
1.3.6.1.4.1.22764.1.1.2.6.2INTEGER (0..99)read-writecurrent
plcSpy
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.2.7
plcSpyIsDynamic
OBJECT-TYPE
True to set the spy dynamic mode
1.3.6.1.4.1.22764.1.1.2.7.1TruthValueread-writecurrent
plcStaticSpySynchBandNb
OBJECT-TYPE
The synchronization band number used for static spy mode
1.3.6.1.4.1.22764.1.1.2.7.2BandValueread-writecurrent
softwareMgnt
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.3
currentSoftwareVersion
OBJECT-TYPE
The name of the current software release.
1.3.6.1.4.1.22764.1.1.3.1DisplayString (SIZE(0..255))read-onlycurrent
currentSoftwareBoardVersion
OBJECT-TYPE
The name of the current software board release.
1.3.6.1.4.1.22764.1.1.3.2DisplayString (SIZE(0..255))read-onlycurrent
currentSoftwareAFEVersion
OBJECT-TYPE
The name of the current software Analog Front End release.
1.3.6.1.4.1.22764.1.1.3.3DisplayString (SIZE(0..255))read-onlycurrent
softwareTable
OBJECT-TYPE
This table contains the current and reserve softwares of the node.
1.3.6.1.4.1.22764.1.1.3.4not-accessiblecurrent
softwareEntry
OBJECT-TYPE
This row contains software information.
1.3.6.1.4.1.22764.1.1.3.4.1not-accessiblecurrent
softwareIndex
OBJECT-TYPE
The index number of the software.
1.3.6.1.4.1.22764.1.1.3.4.1.1SoftwareIndexnot-accessiblecurrent
softwareVersion
OBJECT-TYPE
The name of the software release.
1.3.6.1.4.1.22764.1.1.3.4.1.2DisplayString (SIZE(0..255))read-onlycurrent
softwareUpload
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.3.5
softwareUploadTFTPServerIP
OBJECT-TYPE
The IP address of the TFTP serveur
1.3.6.1.4.1.22764.1.1.3.5.1IpAddressread-writecurrent
softwareUploadLogin
OBJECT-TYPE
The user login on the TFTP server
1.3.6.1.4.1.22764.1.1.3.5.2DisplayString (SIZE(0..16))read-writecurrent
softwareUploadPassword
OBJECT-TYPE
The user password on the TFTP server. Warning: This field is displayed using 6 * characters
1.3.6.1.4.1.22764.1.1.3.5.3DisplayString (SIZE(0..16))read-writecurrent
softwareUploadFileName
OBJECT-TYPE
The software file name to upload
1.3.6.1.4.1.22764.1.1.3.5.4DisplayString (SIZE(0..255))read-writecurrent
softwareUploadProceed
OBJECT-TYPE
True to request the uploading to start
1.3.6.1.4.1.22764.1.1.3.5.5TruthValueread-writecurrent
softwareUploadResult
OBJECT-TYPE
Result value of the requested uploading
1.3.6.1.4.1.22764.1.1.3.5.6SoftwareActionResultValueread-onlycurrent
softwareUploadTFTPServerPort
OBJECT-TYPE
The service port of the TFTP server
1.3.6.1.4.1.22764.1.1.3.5.7Integer32 (0..65535)read-writecurrent
softwareAction
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.3.6
softwareActionIndex
OBJECT-TYPE
The index of the reserve software
1.3.6.1.4.1.22764.1.1.3.6.1SoftwareIndexread-writecurrent
softwareActionType
OBJECT-TYPE
Type of the software action software: switch, remove
1.3.6.1.4.1.22764.1.1.3.6.2SoftwareActionTyperead-writecurrent
softwareActionProceed
OBJECT-TYPE
True to request the switch between the current and the reserver software to start
1.3.6.1.4.1.22764.1.1.3.6.3TruthValueread-writecurrent
softwareActionResult
OBJECT-TYPE
Result value of the requested action
1.3.6.1.4.1.22764.1.1.3.6.4SoftwareActionResultValueread-onlycurrent
plcConformance
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.4
plcCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.4.1
plcGroups
OBJECT-IDENTITY
1.3.6.1.4.1.22764.1.1.4.2
ipExt
OBJECT-IDENTITY
Extended ip needed for SPiDCOM functionalities
1.3.6.1.4.1.22764.1.4current
ipDynamic
OBJECT-TYPE
True if Ip address is set dynamically
1.3.6.1.4.1.22764.1.4.1TruthValueread-writecurrent

Conformance

NameOIDStatus
plcCompliance
MODULE-COMPLIANCE
The compliance statement for SPC200 chip.
1.3.6.1.4.1.22764.1.1.4.1.1current
nodeGroup
OBJECT-GROUP
A collection of objects providing node configuration information.
1.3.6.1.4.1.22764.1.1.4.2.1current
inputNodeGroup
OBJECT-GROUP
A collection of objects used to request node configuration information changes.
1.3.6.1.4.1.22764.1.1.4.2.2current
topologyGroup
OBJECT-GROUP
A collection of objects providing topology configuration.
1.3.6.1.4.1.22764.1.1.4.2.3current
inputTopologyGroup
OBJECT-GROUP
A collection of objects used to request topology configuration changes.
1.3.6.1.4.1.22764.1.1.4.2.4current
statisticGroup
OBJECT-GROUP
A collection of objects providing statistic data on node and plc link performances.
1.3.6.1.4.1.22764.1.1.4.2.5current
softwareGroup
OBJECT-GROUP
A collection of objects providing software management
1.3.6.1.4.1.22764.1.1.4.2.6current
analyserGroup
OBJECT-GROUP
A collection of objects providing spectrum analyser data
1.3.6.1.4.1.22764.1.1.4.2.7current
agentCapabilities
AGENT-CAPABILITIES
The SPC200 chip SNMP agent capabilities
1.3.6.1.4.1.22764.1.1.4.3current
ipExtGroup
OBJECT-GROUP
The fields needed by the SPiDCOM functionalities
1.3.6.1.4.1.22764.1.4.2current