SPC200
- Registered at
- 1.3.6.1.4.1.22764.1
- Last updated
- 2004-12-17 12:30
- Organization
- Organization
- Revisions
- 2004-12-17 12:30, 2004-11-16 12:30, 2004-09-21 12:00, 2004-09-13 12:00, 2004-07-22 12:00, 2004-07-01 17:57
- Namespace
- cdata
- Source file
SPC200- Digest
sha256:7743c5721f4325455b2b075da14857baf6ef3c9a39c9c1eee67bc63307314e11
Description
Description
Contact
Contact-info
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex, interfaces |
| SNMPv2-CONF | AGENT-CAPABILITIES, MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue |
| SPIDCOM-MIB | spidcom |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC SPC200 SPIDCOM-MIB
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AdaptValue TEXTUAL-CONVENTION The adapt level integer value. | current | |||
| BandValue TEXTUAL-CONVENTION A channel is composed of 7 bands. | current | |||
| CarrierValue TEXTUAL-CONVENTION A group is composed of 8 carriers. | current | |||
| ChannelBandwidthValue TEXTUAL-CONVENTION The channel bandwidth integer value. | current | |||
| EstimationMode TEXTUAL-CONVENTION The type of Channel estimation process. Two are available: - automatic, the equipment negociates the best configuration with the remote equipment, - manual, the operator defines the configuration. | current | |||
| GroupValue TEXTUAL-CONVENTION A band is composed of 16 groups. | current | |||
| ModulationValue TEXTUAL-CONVENTION Modulation amplitude used by a group of carriers. | current | |||
| PilotValue TEXTUAL-CONVENTION The pilot carrier wave can be chosen between the carrier 1 up to carrier 128 inside a band carrier range. | current | |||
| PlcChannelType TEXTUAL-CONVENTION The different type of plc channels: rx for the current reception channel, rx last for the last reception channel, tx for the current transmission channel. | current | |||
| PlcModeType TEXTUAL-CONVENTION Type of software management action. | current | |||
| ResultValue TEXTUAL-CONVENTION Result value of input vectors. | current | |||
| SoftwareActionResultValue TEXTUAL-CONVENTION Result value of software action process. | current | |||
| SoftwareActionType TEXTUAL-CONVENTION Type of software management action. | current | |||
| SoftwareIndex TEXTUAL-CONVENTION The software index. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| plc OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1 | |||
| stats OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.1 | |||
| portStatsTable OBJECT-TYPE This table gathers all statistic data specific to SPC200 chip relative to plc connection. | 1.3.6.1.4.1.22764.1.1.1.2 | not-accessible | current | |
| portStatsEntry OBJECT-TYPE This row contains statistic data specific to SPC200 chip relative to a connection. | 1.3.6.1.4.1.22764.1.1.1.2.1 | not-accessible | current | |
| portStatsBandIndex OBJECT-TYPE The band number on which the signal, noise, ber data are collected. | 1.3.6.1.4.1.22764.1.1.1.2.1.1 | BandValue | not-accessible | current |
| portStatsGroupIndex OBJECT-TYPE The group number on which the signal, noise, ber data are collected | 1.3.6.1.4.1.22764.1.1.1.2.1.2 | GroupValue | not-accessible | current |
| portStatsCarrierIndex OBJECT-TYPE The group number on which the signal, noise, ber data are collected | 1.3.6.1.4.1.22764.1.1.1.2.1.3 | CarrierValue | not-accessible | current |
| portStatsSignal OBJECT-TYPE The DB value of the signal associated with the carrier wave entry. | 1.3.6.1.4.1.22764.1.1.1.2.1.4 | Counter32 | read-only | current |
| portStatsNoise OBJECT-TYPE The DB value of the noise associated with the carrier wave entry. | 1.3.6.1.4.1.22764.1.1.1.2.1.5 | Counter32 | read-only | current |
| portStats2Table OBJECT-TYPE This table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in a more compact way. This table has been added to deal with possible slow performances. | 1.3.6.1.4.1.22764.1.1.1.3 | not-accessible | current | |
| portStats2Entry OBJECT-TYPE This row contains statistic data specific to SPC200 chip relative to a connection. | 1.3.6.1.4.1.22764.1.1.1.3.1 | not-accessible | current | |
| portStats2Signal OBJECT-TYPE The values of the signal for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for each 128 carriers of the considered band. | 1.3.6.1.4.1.22764.1.1.1.3.1.1 | OCTET STRING | read-only | current |
| portStats2Noise OBJECT-TYPE The values of the noise for all the carrier waves. The expected format is VALUE VALUE VALUE ... VALUE. Each value is coded on two bytes. There is one value for each 128 carriers of the considered band. | 1.3.6.1.4.1.22764.1.1.1.3.1.2 | OCTET STRING | read-only | current |
| portStats2AvgBandAtt OBJECT-TYPE Average attenuation per band (dB). | 1.3.6.1.4.1.22764.1.1.1.3.1.3 | Counter32 | read-only | current |
| portStats2AvgBandSNR OBJECT-TYPE Average SNR per band (dB). | 1.3.6.1.4.1.22764.1.1.1.3.1.4 | Counter32 | read-only | current |
| portStats3Table OBJECT-TYPE This table gathers all statistic data specific to SPC200 chip relative to plc channels. This table has the same information as the portChannelStatsTable but in a more compact way. This table has been added to deal with possible slow performances. | 1.3.6.1.4.1.22764.1.1.1.4 | not-accessible | current | |
| portStats3Entry OBJECT-TYPE This row contains statistic data specific to SPC200 chip relative to a connection. | 1.3.6.1.4.1.22764.1.1.1.4.1 | not-accessible | current | |
| portStats3AvgAtt OBJECT-TYPE Average attenuation on the link (dB). | 1.3.6.1.4.1.22764.1.1.1.4.1.1 | Counter32 | read-only | current |
| portStats3AvgSNR OBJECT-TYPE Average SNR on the link (dB). | 1.3.6.1.4.1.22764.1.1.1.4.1.2 | Counter32 | read-only | current |
| bootstats OBJECT-IDENTITY boot statistics | 1.3.6.1.4.1.22764.1.1.1.5 | current | ||
| bootstatsBoot OBJECT-TYPE Boot | 1.3.6.1.4.1.22764.1.1.1.5.1 | Counter32 | read-only | current |
| bootstatsManualReset OBJECT-TYPE Manual reset | 1.3.6.1.4.1.22764.1.1.1.5.2 | Counter32 | read-only | current |
| bootstatsFailureReset OBJECT-TYPE Failure reset | 1.3.6.1.4.1.22764.1.1.1.5.3 | Counter32 | read-only | current |
| plcObjects OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2 | |||
| plcMode OBJECT-TYPE Plc Mode | 1.3.6.1.4.1.22764.1.1.2.1 | PlcModeType | read-write | current |
| plcTopo OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.2 | |||
| plcTopoChanges OBJECT-TYPE The total number of topology changes detected by this plc bridge since the management entity was last reset or initialized. Such changes concerns only - the plcBasePortTable rows - the plcBasePortTable columns except for plcBasePortChannelEstimation | 1.3.6.1.4.1.22764.1.1.2.2.1 | Counter32 | read-only | current |
| plcBasePortTable OBJECT-TYPE This table contains the list of plc remote connection | 1.3.6.1.4.1.22764.1.1.2.2.2 | not-accessible | current | |
| plcBasePortEntry OBJECT-TYPE This row contains plc remote connection information | 1.3.6.1.4.1.22764.1.1.2.2.2.1 | not-accessible | current | |
| plcBasePortIndex OBJECT-TYPE The MAC address of the MAC layer above the plc interface of the remote PLC equipment. | 1.3.6.1.4.1.22764.1.1.2.2.2.1.1 | MacAddress | not-accessible | current |
| plcBasePortAddress OBJECT-TYPE The MAC address of the MAC layer above the plc interface of the remote PLC equipment. | 1.3.6.1.4.1.22764.1.1.2.2.2.1.2 | MacAddress | read-only | current |
| plcBasePortChannelEstimation OBJECT-TYPE Enable or disable the automatic channel estimation processus. | 1.3.6.1.4.1.22764.1.1.2.2.2.1.3 | EstimationMode | read-write | current |
| plcBasePortAttenuation OBJECT-TYPE Link attenuation (dB). | 1.3.6.1.4.1.22764.1.1.2.2.2.1.4 | Counter32 | read-only | current |
| plcChannelModulationStringTable OBJECT-TYPE This table contains string values for a quick access to the modulation amplitude configurations of all active channels. | 1.3.6.1.4.1.22764.1.1.2.2.3 | not-accessible | current | |
| plcChannelModulationStringEntry OBJECT-TYPE This row contains string values for a quick access to the modulation amplitude configuration of each active channel of the remote connection referenced by plcBasePortIndex. | 1.3.6.1.4.1.22764.1.1.2.2.3.1 | not-accessible | current | |
| plcRxChannelModulation OBJECT-TYPE The modulation amplitude values for the Rx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits. There are ( 16 groups * 7 bands ) / 2 = 66 values. | 1.3.6.1.4.1.22764.1.1.2.2.3.1.1 | OCTET STRING | read-only | current |
| plcRxLastChannelModulation OBJECT-TYPE The modulation amplitude values for the Rx Last channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits representing ModulationValue - 1. There are ( 16 groups * 7 bands ) / 2 = 66 values. | 1.3.6.1.4.1.22764.1.1.2.2.3.1.2 | OCTET STRING | read-only | current |
| plcTxChannelModulation OBJECT-TYPE The modulation amplitude values for the Tx channel of a given remote connection entry. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing two modulation values. Each modulation is coded on 4 bits. There are ( 16 groups * 7 bands ) / 2 = 66 values. | 1.3.6.1.4.1.22764.1.1.2.2.3.1.3 | OCTET STRING | read-only | current |
| plcChannelModulationTable OBJECT-TYPE This table contains the modulation amplitude configuration of all active channels. | 1.3.6.1.4.1.22764.1.1.2.2.4 | not-accessible | current | |
| plcChannelModulationEntry OBJECT-TYPE This row contains modulation amplitude configuration of the channel, referenced by the plcPortChannelIndex, of the remote connection referenced by plcBasePortIndex. | 1.3.6.1.4.1.22764.1.1.2.2.4.1 | not-accessible | current | |
| plcModBandIndex OBJECT-TYPE The band number of which the modulations are defined | 1.3.6.1.4.1.22764.1.1.2.2.4.1.1 | BandValue | not-accessible | current |
| plcModGroup1 OBJECT-TYPE The modulation amplitude of the first group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.2 | ModulationValue | read-only | current |
| plcModGroup2 OBJECT-TYPE The modulation amplitude of the second group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.3 | ModulationValue | read-only | current |
| plcModGroup3 OBJECT-TYPE The modulation amplitude of the third group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.4 | ModulationValue | read-only | current |
| plcModGroup4 OBJECT-TYPE The modulation amplitude of the fourth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.5 | ModulationValue | read-only | current |
| plcModGroup5 OBJECT-TYPE The modulation amplitude of the fifth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.6 | ModulationValue | read-only | current |
| plcModGroup6 OBJECT-TYPE The modulation amplitude of the sixth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.7 | ModulationValue | read-only | current |
| plcModGroup7 OBJECT-TYPE The modulation amplitude of the seventh group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.8 | ModulationValue | read-only | current |
| plcModGroup8 OBJECT-TYPE The modulation amplitude of the eighth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.9 | ModulationValue | read-only | current |
| plcModGroup9 OBJECT-TYPE The modulation amplitude of the nineth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.10 | ModulationValue | read-only | current |
| plcModGroup10 OBJECT-TYPE The modulation amplitude of the tenth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.11 | ModulationValue | read-only | current |
| plcModGroup11 OBJECT-TYPE The modulation amplitude of the eleventh group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.12 | ModulationValue | read-only | current |
| plcModGroup12 OBJECT-TYPE The modulation amplitude of the twelveth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.13 | ModulationValue | read-only | current |
| plcModGroup13 OBJECT-TYPE The modulation amplitude of the thirteenth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.14 | ModulationValue | read-only | current |
| plcModGroup14 OBJECT-TYPE The modulation amplitude of the fourteenth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.15 | ModulationValue | read-only | current |
| plcModGroup15 OBJECT-TYPE The modulation amplitude of the fifteenth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.16 | ModulationValue | read-only | current |
| plcModGroup16 OBJECT-TYPE The modulation amplitude of the sixteenth group of the band entry of the channel entry for a given remote connection entry. | 1.3.6.1.4.1.22764.1.1.2.2.4.1.17 | ModulationValue | read-only | current |
| plcChannelModulationInput OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.2.5 | |||
| plcModulationInputAddr OBJECT-TYPE The MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the modulation value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.2.5.1 | MacAddress | read-write | current |
| plcModulationInputChannel OBJECT-TYPE The channel type of the remote PLC equipment for which the modulation value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.2.5.2 | PlcChannelType | read-write | current |
| plcModulationInputBand OBJECT-TYPE The band number of which the modulation value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.2.5.3 | BandValue | read-write | current |
| plcInputModulationGroup1 OBJECT-TYPE The new requested modulation amplitude of the first group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.4 | ModulationValue | read-write | current |
| plcInputModulationGroup2 OBJECT-TYPE The new requested modulation amplitude of the second group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.5 | ModulationValue | read-write | current |
| plcInputModulationGroup3 OBJECT-TYPE The new requested modulation amplitude of the third group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.6 | ModulationValue | read-write | current |
| plcInputModulationGroup4 OBJECT-TYPE The new requested modulation amplitude of the fourth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.7 | ModulationValue | read-write | current |
| plcInputModulationGroup5 OBJECT-TYPE The new requested modulation amplitude of the fifth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.8 | ModulationValue | read-write | current |
| plcInputModulationGroup6 OBJECT-TYPE The new requested modulation amplitude of the sixth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.9 | ModulationValue | read-write | current |
| plcInputModulationGroup7 OBJECT-TYPE The new requested modulation amplitude of the seventh group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.10 | ModulationValue | read-write | current |
| plcInputModulationGroup8 OBJECT-TYPE The new requested modulation amplitude of the eighth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.11 | ModulationValue | read-write | current |
| plcInputModulationGroup9 OBJECT-TYPE The new requested modulation amplitude of the nineth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.12 | ModulationValue | read-write | current |
| plcInputModulationGroup10 OBJECT-TYPE The new requested modulation amplitude of the tenth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.13 | ModulationValue | read-write | current |
| plcInputModulationGroup11 OBJECT-TYPE The new requested modulation amplitude of the eleventh group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.14 | ModulationValue | read-write | current |
| plcInputModulationGroup12 OBJECT-TYPE The new requested modulation amplitude of the twelveth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.15 | ModulationValue | read-write | current |
| plcInputModulationGroup13 OBJECT-TYPE The new requested modulation amplitude of the thirteenth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.16 | ModulationValue | read-write | current |
| plcInputModulationGroup14 OBJECT-TYPE The new requested modulation amplitude of the fourteenth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.17 | ModulationValue | read-write | current |
| plcInputModulationGroup15 OBJECT-TYPE The new requested modulation amplitude of the fifteenth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.18 | ModulationValue | read-write | current |
| plcInputModulationGroup16 OBJECT-TYPE The new requested modulation amplitude of the sixteenth group of the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.5.19 | ModulationValue | read-write | current |
| plcModulationInputProceed OBJECT-TYPE True to request a modification of all the modulations associated to a band and a channel of a remote PLC equipment. | 1.3.6.1.4.1.22764.1.1.2.2.5.20 | TruthValue | read-write | current |
| plcModulationInputResult OBJECT-TYPE Result value of the requested modulation value changes. | 1.3.6.1.4.1.22764.1.1.2.2.5.21 | ResultValue | read-only | current |
| plcPortChannelTable OBJECT-TYPE This table contains the list of plc channels | 1.3.6.1.4.1.22764.1.1.2.2.6 | not-accessible | current | |
| plcPortChannelEntry OBJECT-TYPE This row contains plc channel information | 1.3.6.1.4.1.22764.1.1.2.2.6.1 | not-accessible | current | |
| plcPortChannelIndex OBJECT-TYPE The channel number belongs to the remote connection with plc equipment associated with the plcBasePortIndex value. Only three channels are expected. Index 1 for RX channel Index 2 for RXLast channel index 3 for TX channel | 1.3.6.1.4.1.22764.1.1.2.2.6.1.1 | Unsigned32 | not-accessible | current |
| plcPortChannelType OBJECT-TYPE The channel type. | 1.3.6.1.4.1.22764.1.1.2.2.6.1.2 | PlcChannelType | read-only | current |
| plcPortChannelGain OBJECT-TYPE The gain associated with the channel. | 1.3.6.1.4.1.22764.1.1.2.2.6.1.3 | Integer32 | read-write | current |
| plcPortChannelBandwidth OBJECT-TYPE The bandwidth of the channel in Kbit/s. | 1.3.6.1.4.1.22764.1.1.2.2.6.1.4 | ChannelBandwidthValue | read-only | current |
| plcPortChannelMaxBandwidth OBJECT-TYPE The maximum bandwidth of the channel in Kbit/s. | 1.3.6.1.4.1.22764.1.1.2.2.6.1.5 | ChannelBandwidthValue | read-only | current |
| plcPortChannelSynchronizationBand OBJECT-TYPE The synchronization band used for this channel. | 1.3.6.1.4.1.22764.1.1.2.2.6.1.6 | BandValue | read-only | current |
| plcChannelPilotStringTable OBJECT-TYPE This table contains the string values representing of pilot values of all active channels. | 1.3.6.1.4.1.22764.1.1.2.2.7 | not-accessible | current | |
| plcChannelPilotStringEntry OBJECT-TYPE This row contains a quick access for pilot values , of the remote connection referenced by plcBasePortIndex. | 1.3.6.1.4.1.22764.1.1.2.2.7.1 | not-accessible | current | |
| plcRxChannelPilots OBJECT-TYPE The carrier wave numbers which support the pilot waves for the Rx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands. | 1.3.6.1.4.1.22764.1.1.2.2.7.1.1 | OCTET STRING | read-only | current |
| plcRxLastChannelPilots OBJECT-TYPE The carrier wave numbers which support the pilot waves for the Rx Last Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands. | 1.3.6.1.4.1.22764.1.1.2.2.7.1.2 | OCTET STRING | read-only | current |
| plcTxChannelPilots OBJECT-TYPE The carrier wave numbers which support the pilot waves for the Tx Channel. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands. | 1.3.6.1.4.1.22764.1.1.2.2.7.1.3 | OCTET STRING | read-only | current |
| plcChannelPilotsTable OBJECT-TYPE This tabel contains pilots configuration for each plc channel. | 1.3.6.1.4.1.22764.1.1.2.2.8 | not-accessible | current | |
| plcChannelPilotsEntry OBJECT-TYPE This row contains the pilots 1 and 2 configuration for a channel defined by the couple (plcBasePortIndex, plcPortChannelIndex) | 1.3.6.1.4.1.22764.1.1.2.2.8.1 | not-accessible | current | |
| plcChannelPilotBandIndex OBJECT-TYPE The band number on which the pilots are defined. | 1.3.6.1.4.1.22764.1.1.2.2.8.1.1 | BandValue | not-accessible | current |
| plcChannelPilot1 OBJECT-TYPE The carrier wave number which supports the first pilot wave for the channel associated with this entry. | 1.3.6.1.4.1.22764.1.1.2.2.8.1.2 | PilotValue | read-only | current |
| plcChannePilot2 OBJECT-TYPE The carrier wave number which supports the second pilot wave for the channel associated with this entry. | 1.3.6.1.4.1.22764.1.1.2.2.8.1.3 | PilotValue | read-only | current |
| plcChannelPilotsInput OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.2.9 | |||
| plcPilotsInputAddr OBJECT-TYPE The MAC address of the MAC layer above the plc interface of the remote PLC equipment for which the pilot value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.2.9.1 | MacAddress | read-write | current |
| plcPilotsInputChannel OBJECT-TYPE The channel type of the remote PLC equipment for which the pilot value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.2.9.2 | PlcChannelType | read-write | current |
| plcPilotsInputBand OBJECT-TYPE The band number of which the pilots value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.2.9.3 | BandValue | read-write | current |
| plcInputChannelPilot1 OBJECT-TYPE The carrier wave number which supports the first pilot wave for the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.9.4 | PilotValue | read-write | current |
| plcInputChannelPilot2 OBJECT-TYPE The carrier wave number which supports the second pilot wave for the considered band and channel input values. | 1.3.6.1.4.1.22764.1.1.2.2.9.5 | PilotValue | read-write | current |
| plcPilotsInputProceed OBJECT-TYPE True to request a modification of the first and second pilot associated to a band and a channel of a remote PLC equipment. | 1.3.6.1.4.1.22764.1.1.2.2.9.6 | TruthValue | read-write | current |
| plcPilotsInputResult OBJECT-TYPE Result value of the requested pilot values changes. | 1.3.6.1.4.1.22764.1.1.2.2.9.7 | ResultValue | read-only | current |
| plcNodeConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3 | |||
| plcNodeNotches OBJECT-TYPE The values of the notches for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is an octet representing the 8 notches of each group. There is one value for each 7 * 16 bands. | 1.3.6.1.4.1.22764.1.1.2.3.1 | OCTET STRING | read-only | current |
| plcNodeNotchesTable OBJECT-TYPE This table contains Notches configuration for the SPC200 chip. | 1.3.6.1.4.1.22764.1.1.2.3.2 | not-accessible | current | |
| plcNodeNotchesEntry OBJECT-TYPE This row contains Notches configuration for a group. The group is defined by the couple (plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex). | 1.3.6.1.4.1.22764.1.1.2.3.2.1 | not-accessible | current | |
| plcNodeNotchesBandIndex OBJECT-TYPE The band number on which the notches are defined. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.1 | BandValue | not-accessible | current |
| plcNodeNotchesGroupIndex OBJECT-TYPE The group number on which the notches are defined. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.2 | GroupValue | not-accessible | current |
| plcNodeNotchesCarrier1 OBJECT-TYPE Tell if the first carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.3 | TruthValue | read-only | current |
| plcNodeNotchesCarrier2 OBJECT-TYPE Tell if the second carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.4 | TruthValue | read-only | current |
| plcNodeNotchesCarrier3 OBJECT-TYPE Tell if the third carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.5 | TruthValue | read-only | current |
| plcNodeNotchesCarrier4 OBJECT-TYPE Tell if the fourth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.6 | TruthValue | read-only | current |
| plcNodeNotchesCarrier5 OBJECT-TYPE Tell if the fifth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.7 | TruthValue | read-only | current |
| plcNodeNotchesCarrier6 OBJECT-TYPE Tell if the sixth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.8 | TruthValue | read-only | current |
| plcNodeNotchesCarrier7 OBJECT-TYPE Tell if the seventh carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.9 | TruthValue | read-only | current |
| plcNodeNotchesCarrier8 OBJECT-TYPE Tell if the eighth carrier of the group entry of the band entry is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.2.1.10 | TruthValue | read-only | current |
| plcNodeNotchesInput OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.3 | |||
| plcNodeNotchesInputBand OBJECT-TYPE The band number on which the notches value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.3.3.1 | BandValue | read-write | current |
| plcNodeNotchesInputGroup OBJECT-TYPE The group number on which the notches value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.3.3.2 | GroupValue | read-write | current |
| plcNodeNotchesInputCarrier1 OBJECT-TYPE The first carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.3 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier2 OBJECT-TYPE The second carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.4 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier3 OBJECT-TYPE The third carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.5 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier4 OBJECT-TYPE The fourth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.6 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier5 OBJECT-TYPE The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.7 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier6 OBJECT-TYPE The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.8 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier7 OBJECT-TYPE The seventh carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.9 | TruthValue | read-write | current |
| plcNodeNotchesInputCarrier8 OBJECT-TYPE The eighth carrier of the considered group and band is a notch carrier. The true value means the current carrier is a notch. | 1.3.6.1.4.1.22764.1.1.2.3.3.10 | TruthValue | read-write | current |
| plcNodeNotchesInputProceed OBJECT-TYPE True to request a modification of the carrier notches associated to the considered group and band. | 1.3.6.1.4.1.22764.1.1.2.3.3.11 | TruthValue | read-write | current |
| plcNodeNotchesInputResult OBJECT-TYPE Result value of the requested node carrier notches value changes. | 1.3.6.1.4.1.22764.1.1.2.3.3.12 | ResultValue | read-only | current |
| plcNodePilots OBJECT-TYPE The values of the pilot for all the node bands. The expected format is VALUE VALUE VALUE ... VALUE. Each value is a pair of octets representing the pilot values. There is one pair (pilot1 pilot2) for each of the 7 bands. | 1.3.6.1.4.1.22764.1.1.2.3.4 | OCTET STRING | read-only | current |
| plcNodePilotsTable OBJECT-TYPE This table contains pilot values used by default on all channels. | 1.3.6.1.4.1.22764.1.1.2.3.5 | not-accessible | current | |
| plcNodePilotsEntry OBJECT-TYPE This row contains pilot values used by default on a band. The band is defined by the index plcNodePilotsBandIndex. | 1.3.6.1.4.1.22764.1.1.2.3.5.1 | not-accessible | current | |
| plcNodePilotsBandIndex OBJECT-TYPE The band number on which the pilot values are defined. | 1.3.6.1.4.1.22764.1.1.2.3.5.1.1 | BandValue | not-accessible | current |
| plcNodePilot1 OBJECT-TYPE The default carrier wave number which supports the first pilot wave. | 1.3.6.1.4.1.22764.1.1.2.3.5.1.2 | PilotValue | read-only | current |
| plcNodePilot2 OBJECT-TYPE The default carrier wave number which supports the second pilot wave. | 1.3.6.1.4.1.22764.1.1.2.3.5.1.3 | PilotValue | read-only | current |
| plcNodePilotsInput OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.6 | |||
| plcNodePilotsInputBand OBJECT-TYPE The band number on which the pilot values changes are requested. | 1.3.6.1.4.1.22764.1.1.2.3.6.1 | BandValue | read-write | current |
| plcInputNodePilot1 OBJECT-TYPE The default carrier wave number which supports the first pilot wave of the considered band. | 1.3.6.1.4.1.22764.1.1.2.3.6.2 | PilotValue | read-write | current |
| plcInputNodePilot2 OBJECT-TYPE The default carrier wave number which supports the second pilot wave of the considered band. | 1.3.6.1.4.1.22764.1.1.2.3.6.3 | PilotValue | read-write | current |
| plcNodePilotsInputProceed OBJECT-TYPE True to request a modification of the pilot values associated to the considered band. | 1.3.6.1.4.1.22764.1.1.2.3.6.4 | TruthValue | read-write | current |
| plcNodePilotsInputResult OBJECT-TYPE Result value of the requested node pilot values changes. | 1.3.6.1.4.1.22764.1.1.2.3.6.5 | ResultValue | read-only | current |
| plcNodeAdaptsStringTable OBJECT-TYPE This table contains string values for a quick access to the adapt configurations of all the carriers. | 1.3.6.1.4.1.22764.1.1.2.3.7 | not-accessible | current | |
| plcNodeAdaptsStringEntry OBJECT-TYPE This row contains string values for a quick access to the adapt configuration of each carrier of a band. | 1.3.6.1.4.1.22764.1.1.2.3.7.1 | not-accessible | current | |
| plcNodeAdaptsStringBandIndex OBJECT-TYPE The band number on which the adapt values are defined. | 1.3.6.1.4.1.22764.1.1.2.3.7.1.1 | BandValue | not-accessible | current |
| plcNodeAdaptsStringBand OBJECT-TYPE The adapt values of the 128 carriers of a band. The expected format is VALUE VALUE VALUE ... VALUE. Each value is two octets representing one adapt carrier level. There are ( 16 groups * 8 carriers) = 128 values. | 1.3.6.1.4.1.22764.1.1.2.3.7.1.2 | OCTET STRING | read-only | current |
| plcNodeAdaptsTable OBJECT-TYPE This table contains adapt level configuration for each carrier of the node. | 1.3.6.1.4.1.22764.1.1.2.3.8 | not-accessible | current | |
| plcNodeAdaptsEntry OBJECT-TYPE This row contains adapt level values for a group of carriers. The group is defined by the couple (plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex). | 1.3.6.1.4.1.22764.1.1.2.3.8.1 | not-accessible | current | |
| plcNodeAdaptsBandIndex OBJECT-TYPE The band number on which the adapt values are defined. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.1 | BandValue | not-accessible | current |
| plcNodeAdaptsGroupIndex OBJECT-TYPE The group number on which the adapt values are defined. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.2 | GroupValue | not-accessible | current |
| plcNodeAdaptsCarrier1 OBJECT-TYPE The adapt level of the first carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.3 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier2 OBJECT-TYPE The adapt level of the second carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.4 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier3 OBJECT-TYPE The adapt level of the third carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.5 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier4 OBJECT-TYPE The adapt level of the fourth carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.6 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier5 OBJECT-TYPE The adapt level of the fifth carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.7 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier6 OBJECT-TYPE The adapt level of the sixth carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.8 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier7 OBJECT-TYPE The adapt level of the seventh carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.9 | AdaptValue | read-only | current |
| plcNodeAdaptsCarrier8 OBJECT-TYPE The adapt level of the eighth carrier of the group. | 1.3.6.1.4.1.22764.1.1.2.3.8.1.10 | AdaptValue | read-only | current |
| plcNodeAdaptsInput OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.9 | |||
| plcNodeAdaptsInputBand OBJECT-TYPE The band number on which the adapt level value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.3.9.1 | BandValue | read-write | current |
| plcNodeAdaptsInputGroup OBJECT-TYPE The group number on which the adapt level value changes are requested. | 1.3.6.1.4.1.22764.1.1.2.3.9.2 | GroupValue | read-write | current |
| plcNodeAdaptsInputCarrier1 OBJECT-TYPE The adapt level of the first carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.3 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier2 OBJECT-TYPE The adapt level of the second carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.4 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier3 OBJECT-TYPE The adapt level of the third carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.5 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier4 OBJECT-TYPE The adapt level of the fourth carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.6 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier5 OBJECT-TYPE The adapt level of the fifth carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.7 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier6 OBJECT-TYPE The adapt level of the sixth carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.8 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier7 OBJECT-TYPE The adapt level of the seventh carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.9 | AdaptValue | read-write | current |
| plcNodeAdaptsInputCarrier8 OBJECT-TYPE The adapt level of the eighth carrier of the considered group of the chosen band. | 1.3.6.1.4.1.22764.1.1.2.3.9.10 | AdaptValue | read-write | current |
| plcNodeAdaptsInputProceed OBJECT-TYPE True to request a modification of the carrier adapt level associated to the considered group and band. | 1.3.6.1.4.1.22764.1.1.2.3.9.11 | TruthValue | read-write | current |
| plcNodeAdaptsInputResult OBJECT-TYPE Result value of the requested node adapt level value changes. | 1.3.6.1.4.1.22764.1.1.2.3.9.12 | ResultValue | read-only | current |
| plcNodeNetConfigTable OBJECT-TYPE This table contains ip and mac addresses of the node. | 1.3.6.1.4.1.22764.1.1.2.3.10 | not-accessible | current | |
| plcNodeNetConfigEntry OBJECT-TYPE This row contains ip and mac address used by an interface. | 1.3.6.1.4.1.22764.1.1.2.3.10.1 | not-accessible | current | |
| plcNodeIpAddr OBJECT-TYPE The IP address of the IP layer above the interface. | 1.3.6.1.4.1.22764.1.1.2.3.10.1.1 | IpAddress | read-write | current |
| plcNodeNetMask OBJECT-TYPE The IP Subnet mask of the IP layer above the interface. | 1.3.6.1.4.1.22764.1.1.2.3.10.1.2 | IpAddress | read-write | current |
| plcNodeMacAddr OBJECT-TYPE The MAC address of the MAC layer above the interface. | 1.3.6.1.4.1.22764.1.1.2.3.10.1.3 | MacAddress | read-write | current |
| plcNodeGateway OBJECT-TYPE The Gateway address of the IP layer above the interface. | 1.3.6.1.4.1.22764.1.1.2.3.10.1.4 | IpAddress | read-write | current |
| plcNodeActions OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.11 | |||
| plcNodeActionsCommit OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.11.1 | |||
| plcNodeActionsCommitProceed OBJECT-TYPE True to request the commit of the configuration changes into the flash memory | 1.3.6.1.4.1.22764.1.1.2.3.11.1.1 | TruthValue | read-write | current |
| plcNodeActionsCommitResult OBJECT-TYPE Result value of the requested flash commit operation. | 1.3.6.1.4.1.22764.1.1.2.3.11.1.2 | ResultValue | read-only | current |
| plcNodeActionsReset OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.11.2 | |||
| plcNodeActionsResetProceed OBJECT-TYPE True to request the reset of the node. This operation will terminate the communication between the manager and the node | 1.3.6.1.4.1.22764.1.1.2.3.11.2.1 | TruthValue | read-write | current |
| plcNodeActionsCarrier OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.3.11.3 | |||
| plcNodeActionsCarrierFlatProceed OBJECT-TYPE True to request the equipment to flat the signal | 1.3.6.1.4.1.22764.1.1.2.3.11.3.1 | TruthValue | read-write | current |
| plcSNAnalyser OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.4 | |||
| plcSNAnalyserEnable OBJECT-TYPE true if the modem should turn to spectrum analyser mode. In this mode the modem enters a receive only mode, and captures periodic samples of the signal on the powerline. The spectrum analyser mode shall be disabled for normal powerline modem operation. | 1.3.6.1.4.1.22764.1.1.2.4.1 | INTEGER {true(1), false(2)} | read-write | current |
| plcSNAnalyserTable OBJECT-TYPE This table gathers all statistic data specific to SPC200 chip relative to plc analyser. | 1.3.6.1.4.1.22764.1.1.2.4.2 | not-accessible | current | |
| plcSNAnalyserEntry OBJECT-TYPE This row contains statistic data specific to SPC200 chip relative to a band. | 1.3.6.1.4.1.22764.1.1.2.4.2.1 | not-accessible | current | |
| plcSNAnalyserMinSignal OBJECT-TYPE Minimum signal measured over several samples for the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113 | 1.3.6.1.4.1.22764.1.1.2.4.2.1.1 | OCTET STRING | read-only | current |
| plcSNAnalyserMaxSignal OBJECT-TYPE Maximum signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113 | 1.3.6.1.4.1.22764.1.1.2.4.2.1.2 | OCTET STRING | read-only | current |
| plcSNAnalyserAvgSignal OBJECT-TYPE Average signal measured on several samples for the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113 | 1.3.6.1.4.1.22764.1.1.2.4.2.1.3 | OCTET STRING | read-only | current |
| plcSNAnalyserLastSignal OBJECT-TYPE Signal measured for last sample on the associated carrier wave entry. The value is expressed in Glomer© which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer©) - 113 | 1.3.6.1.4.1.22764.1.1.2.4.2.1.4 | OCTET STRING | read-only | current |
| plcSNAnalyserFFTDiv OBJECT-TYPE FFT division factor on the associated band. | 1.3.6.1.4.1.22764.1.1.2.4.2.1.5 | Counter32 | read-only | current |
| plcSNAnalyserAGC OBJECT-TYPE Gain factor in dB, as used by the Automatic Gain Control last sample | 1.3.6.1.4.1.22764.1.1.2.4.3 | Integer32 (0..255) | read-only | current |
| plcAGCAnalyser OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.5 | |||
| plcAGCAnalyserEnable OBJECT-TYPE | 1.3.6.1.4.1.22764.1.1.2.5.1 | INTEGER {true(1), false(2)} | read-write | current |
| plcAGCAnalyserSamplesPart1 OBJECT-TYPE | 1.3.6.1.4.1.22764.1.1.2.5.2 | OCTET STRING | read-only | current |
| plcAGCAnalyserSamplesPart2 OBJECT-TYPE | 1.3.6.1.4.1.22764.1.1.2.5.3 | OCTET STRING | read-only | current |
| plcBssId OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.6 | |||
| plcMasterBssId OBJECT-TYPE The value of the master Bss Id | 1.3.6.1.4.1.22764.1.1.2.6.1 | INTEGER (0..99) | read-write | current |
| plcSlaveBssId OBJECT-TYPE The value of the slave Bss Id | 1.3.6.1.4.1.22764.1.1.2.6.2 | INTEGER (0..99) | read-write | current |
| plcSpy OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.2.7 | |||
| plcSpyIsDynamic OBJECT-TYPE True to set the spy dynamic mode | 1.3.6.1.4.1.22764.1.1.2.7.1 | TruthValue | read-write | current |
| plcStaticSpySynchBandNb OBJECT-TYPE The synchronization band number used for static spy mode | 1.3.6.1.4.1.22764.1.1.2.7.2 | BandValue | read-write | current |
| softwareMgnt OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.3 | |||
| currentSoftwareVersion OBJECT-TYPE The name of the current software release. | 1.3.6.1.4.1.22764.1.1.3.1 | DisplayString (SIZE(0..255)) | read-only | current |
| currentSoftwareBoardVersion OBJECT-TYPE The name of the current software board release. | 1.3.6.1.4.1.22764.1.1.3.2 | DisplayString (SIZE(0..255)) | read-only | current |
| currentSoftwareAFEVersion OBJECT-TYPE The name of the current software Analog Front End release. | 1.3.6.1.4.1.22764.1.1.3.3 | DisplayString (SIZE(0..255)) | read-only | current |
| softwareTable OBJECT-TYPE This table contains the current and reserve softwares of the node. | 1.3.6.1.4.1.22764.1.1.3.4 | not-accessible | current | |
| softwareEntry OBJECT-TYPE This row contains software information. | 1.3.6.1.4.1.22764.1.1.3.4.1 | not-accessible | current | |
| softwareIndex OBJECT-TYPE The index number of the software. | 1.3.6.1.4.1.22764.1.1.3.4.1.1 | SoftwareIndex | not-accessible | current |
| softwareVersion OBJECT-TYPE The name of the software release. | 1.3.6.1.4.1.22764.1.1.3.4.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| softwareUpload OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.3.5 | |||
| softwareUploadTFTPServerIP OBJECT-TYPE The IP address of the TFTP serveur | 1.3.6.1.4.1.22764.1.1.3.5.1 | IpAddress | read-write | current |
| softwareUploadLogin OBJECT-TYPE The user login on the TFTP server | 1.3.6.1.4.1.22764.1.1.3.5.2 | DisplayString (SIZE(0..16)) | read-write | current |
| softwareUploadPassword OBJECT-TYPE The user password on the TFTP server. Warning: This field is displayed using 6 * characters | 1.3.6.1.4.1.22764.1.1.3.5.3 | DisplayString (SIZE(0..16)) | read-write | current |
| softwareUploadFileName OBJECT-TYPE The software file name to upload | 1.3.6.1.4.1.22764.1.1.3.5.4 | DisplayString (SIZE(0..255)) | read-write | current |
| softwareUploadProceed OBJECT-TYPE True to request the uploading to start | 1.3.6.1.4.1.22764.1.1.3.5.5 | TruthValue | read-write | current |
| softwareUploadResult OBJECT-TYPE Result value of the requested uploading | 1.3.6.1.4.1.22764.1.1.3.5.6 | SoftwareActionResultValue | read-only | current |
| softwareUploadTFTPServerPort OBJECT-TYPE The service port of the TFTP server | 1.3.6.1.4.1.22764.1.1.3.5.7 | Integer32 (0..65535) | read-write | current |
| softwareAction OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.3.6 | |||
| softwareActionIndex OBJECT-TYPE The index of the reserve software | 1.3.6.1.4.1.22764.1.1.3.6.1 | SoftwareIndex | read-write | current |
| softwareActionType OBJECT-TYPE Type of the software action software: switch, remove | 1.3.6.1.4.1.22764.1.1.3.6.2 | SoftwareActionType | read-write | current |
| softwareActionProceed OBJECT-TYPE True to request the switch between the current and the reserver software to start | 1.3.6.1.4.1.22764.1.1.3.6.3 | TruthValue | read-write | current |
| softwareActionResult OBJECT-TYPE Result value of the requested action | 1.3.6.1.4.1.22764.1.1.3.6.4 | SoftwareActionResultValue | read-only | current |
| plcConformance OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.4 | |||
| plcCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.4.1 | |||
| plcGroups OBJECT-IDENTITY | 1.3.6.1.4.1.22764.1.1.4.2 | |||
| ipExt OBJECT-IDENTITY Extended ip needed for SPiDCOM functionalities | 1.3.6.1.4.1.22764.1.4 | current | ||
| ipDynamic OBJECT-TYPE True if Ip address is set dynamically | 1.3.6.1.4.1.22764.1.4.1 | TruthValue | read-write | current |
Conformance
| Name | OID | Status |
|---|---|---|
| plcCompliance MODULE-COMPLIANCE The compliance statement for SPC200 chip. | 1.3.6.1.4.1.22764.1.1.4.1.1 | current |
| nodeGroup OBJECT-GROUP A collection of objects providing node configuration information. | 1.3.6.1.4.1.22764.1.1.4.2.1 | current |
| inputNodeGroup OBJECT-GROUP A collection of objects used to request node configuration information changes. | 1.3.6.1.4.1.22764.1.1.4.2.2 | current |
| topologyGroup OBJECT-GROUP A collection of objects providing topology configuration. | 1.3.6.1.4.1.22764.1.1.4.2.3 | current |
| inputTopologyGroup OBJECT-GROUP A collection of objects used to request topology configuration changes. | 1.3.6.1.4.1.22764.1.1.4.2.4 | current |
| statisticGroup OBJECT-GROUP A collection of objects providing statistic data on node and plc link performances. | 1.3.6.1.4.1.22764.1.1.4.2.5 | current |
| softwareGroup OBJECT-GROUP A collection of objects providing software management | 1.3.6.1.4.1.22764.1.1.4.2.6 | current |
| analyserGroup OBJECT-GROUP A collection of objects providing spectrum analyser data | 1.3.6.1.4.1.22764.1.1.4.2.7 | current |
| agentCapabilities AGENT-CAPABILITIES The SPC200 chip SNMP agent capabilities | 1.3.6.1.4.1.22764.1.1.4.3 | current |
| ipExtGroup OBJECT-GROUP The fields needed by the SPiDCOM functionalities | 1.3.6.1.4.1.22764.1.4.2 | current |