SLE-PM-MIB
- Registered at
- 1.3.6.1.4.1.6296.101.94
- Last updated
- 2015-11-30 00:00
- Organization
- Revisions
- 2015-11-30 00:00
- Namespace
- dasan
- Source file
SLE-PM-MIB- Digest
sha256:deb948ab4564de343c3ddf230a55f60a44c5841f7251552a51bada9d75f417a0
Description
This MIB contains all needed informations about Performance Manager.
Imports
| From | Symbols |
|---|---|
| DASAN-SMI | sleMgmt |
| SLE-TC-MIB | SleControlRequestResultType, SleControlStatusType |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Counter64, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, zeroDotZero |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
DASAN-SMI SLE-PM-MIB SLE-TC-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| PmClassId TEXTUAL-CONVENTION Description. | current | |||
| PmDateTime TEXTUAL-CONVENTION TOD integer value | current | |||
| PmId TEXTUAL-CONVENTION Current PM ID | current | |||
| PmSrc TEXTUAL-CONVENTION |type|length|value|type|length|value|.... type (1-byte) : PM location type length(1-byte) : PM location value length value (length-bytes) : PM location value | current | |||
| PmTcaState TEXTUAL-CONVENTION This status explains whether TRAP status is enabled or disabled. Enable(1) : TCA State is Enabled. Hence TRAPs will be sent for this. Disable(0) : TCA State is Disabled. So TCA won't be notified to user. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| slePmNeId OBJECT-TYPE system MAC address | 1.3.6.1.4.1.6296.101.94.1 | OCTET STRING (SIZE(6)) | read-only | current |
| slePmConfigBase OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.2 | |||
| slePmConfigTable OBJECT-TYPE This table is the Performance Config table. It gets populated when system init is done. And it contains all the class performance supported for the device | 1.3.6.1.4.1.6296.101.94.2.1 | not-accessible | current | |
| slePmConfigEntry OBJECT-TYPE | 1.3.6.1.4.1.6296.101.94.2.1.1 | not-accessible | current | |
| slePmConfigSeqId OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.2.1.1.1 | INTEGER (1..65535) | read-only | current |
| slePmConfigClassId OBJECT-TYPE Class ID starts from 1 to 255 for the system. And these IDs are generated internally | 1.3.6.1.4.1.6296.101.94.2.1.1.2 | PmClassId | read-only | current |
| slePmConfigPmId OBJECT-TYPE Current PM ID | 1.3.6.1.4.1.6296.101.94.2.1.1.3 | PmId | read-only | current |
| slePmConfigSource OBJECT-TYPE |type|length|value|type|length|value|.... type (1-byte) : PM location type length(1-byte) : PM location value length value (length-bytes) : PM location value | 1.3.6.1.4.1.6296.101.94.2.1.1.4 | PmSrc | read-only | current |
| slePmConfigTcaStat OBJECT-TYPE TCA status TCA Normal (0) TCA Occur (1) | 1.3.6.1.4.1.6296.101.94.2.1.1.5 | INTEGER {tcaNormal(0), tcaOccur(1)} | read-only | current |
| slePmConfigTcaEnable OBJECT-TYPE TCA enable Confguration : enabled or disabled. Enable(1) : TCA State is Enabled. Hence TRAPs will be sent for this. Disable(0) : TCA State is Disabled. So TCA won't be notified to user. | 1.3.6.1.4.1.6296.101.94.2.1.1.6 | PmTcaState | read-only | current |
| slePmConfigTh15Min OBJECT-TYPE 15minute Performance TCA threshold configuration count | 1.3.6.1.4.1.6296.101.94.2.1.1.7 | Counter64 | read-only | current |
| slePmConfigTh1Day OBJECT-TYPE 1day Performance TCA threshold configuration count | 1.3.6.1.4.1.6296.101.94.2.1.1.8 | Counter64 | read-write | current |
| slePmConfigControl OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.2.2 | |||
| slePmConfigControlRequest OBJECT-TYPE The configuration commands, and user can configure functions via setting this entry as proper value. | 1.3.6.1.4.1.6296.101.94.2.2.1 | INTEGER {setPmConfigTcaEnable(1), setPmConfigTh15Min(2), setPmConfigTh1Day(3)} | read-write | current |
| slePmConfigControlStatus OBJECT-TYPE status of user command. User have to check this value as .busy. or .idle. before do setRequest. | 1.3.6.1.4.1.6296.101.94.2.2.2 | SleControlStatusType | read-only | current |
| slePmConfigControlTimer OBJECT-TYPE the wait-time until setRequest end. In case of short-time command, this value is 0 | 1.3.6.1.4.1.6296.101.94.2.2.3 | Gauge32 | read-write | current |
| slePmConfigControlTimeStamp OBJECT-TYPE the time stamp of the last command. (don.t care) | 1.3.6.1.4.1.6296.101.94.2.2.4 | TimeTicks | read-only | current |
| slePmConfigControlReqResult OBJECT-TYPE Result of the last command. | 1.3.6.1.4.1.6296.101.94.2.2.5 | SleControlRequestResultType | read-only | current |
| slePmConfigControlSeqId OBJECT-TYPE PM Manager Class ID | 1.3.6.1.4.1.6296.101.94.2.2.6 | Integer32 | read-write | current |
| slePmConfigControlTcaEnable OBJECT-TYPE TCA enable Confguration : enabled or disabled. Enable(1) : TCA State is Enabled. Hence TRAPs will be sent for this. Disable(0) : TCA State is Disabled. So TCA won't be notified to user. | 1.3.6.1.4.1.6296.101.94.2.2.7 | PmTcaState | read-write | current |
| slePmConfigControlTh15Min OBJECT-TYPE 15minute Performance TCA threshold configuration count | 1.3.6.1.4.1.6296.101.94.2.2.8 | Counter64 | read-write | current |
| slePmConfigControlTh1Day OBJECT-TYPE 1day Performance TCA threshold configuration count | 1.3.6.1.4.1.6296.101.94.2.2.9 | Counter64 | read-write | current |
| slePmConfigNotification OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.2.3 | |||
| slePmCurrentBase OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.3 | |||
| slePmCurrentTable OBJECT-TYPE This table contains the current PM count. | 1.3.6.1.4.1.6296.101.94.3.1 | not-accessible | current | |
| slePmCurrentEntry OBJECT-TYPE | 1.3.6.1.4.1.6296.101.94.3.1.1 | not-accessible | current | |
| slePmCurrentSeqId OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.3.1.1.1 | INTEGER (1..65535) | read-only | current |
| slePmCurrentClassId OBJECT-TYPE Current Class ID | 1.3.6.1.4.1.6296.101.94.3.1.1.2 | PmClassId | read-only | current |
| slePmCurrentPmId OBJECT-TYPE Current PM ID | 1.3.6.1.4.1.6296.101.94.3.1.1.3 | PmId | read-only | current |
| slePmCurrentSource OBJECT-TYPE |type|length|value|type|length|value|.... type (1-byte) : PM location type length(1-byte) : PM location value length value (length-bytes) : PM location value | 1.3.6.1.4.1.6296.101.94.3.1.1.4 | PmSrc | read-only | current |
| slePmCurrentTerm OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.3.1.1.5 | INTEGER {min15(1), day1(2)} | read-write | current |
| slePmCurrentPmCount OBJECT-TYPE Current Performance count | 1.3.6.1.4.1.6296.101.94.3.1.1.6 | Counter64 | read-only | current |
| slePmCurrentAccSecond OBJECT-TYPE Current Performance data accumulation seconds(count) | 1.3.6.1.4.1.6296.101.94.3.1.1.7 | Counter32 | read-only | current |
| slePmCurrentTcaStat OBJECT-TYPE TCA status TCA Normal (0) TCA Occur (1) | 1.3.6.1.4.1.6296.101.94.3.1.1.8 | INTEGER {tcaNormal(0), tcaOccur(1)} | read-only | current |
| slePmCurrentTcaTime OBJECT-TYPE Current PM Time and Date | 1.3.6.1.4.1.6296.101.94.3.1.1.9 | TimeTicks | read-only | current |
| slePmCurrentControl OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.3.2 | |||
| slePmCurrentControlRequest OBJECT-TYPE The configuration commands, and user can configure functions via setting this entry as proper value. clearCurrentPm(1): Clears the current Performance count (both 15min and 1day) PM history(accumulation) count is not cleared clearCurrentTca(2): Clears the current Performance TCA flag (both 15min and 1day) | 1.3.6.1.4.1.6296.101.94.3.2.1 | INTEGER {clearCurrentPm(1), clearCurrentTca(2)} | read-write | current |
| slePmCurrentControlStatus OBJECT-TYPE status of user command. User have to check this value as .busy. or .idle. before do setRequest. | 1.3.6.1.4.1.6296.101.94.3.2.2 | SleControlStatusType | read-only | current |
| slePmCurrentControlTimer OBJECT-TYPE the wait-time until setRequest end. In case of short-time command, this value is 0 | 1.3.6.1.4.1.6296.101.94.3.2.3 | Gauge32 | read-write | current |
| slePmCurrentControlTimeStamp OBJECT-TYPE the time stamp of the last command. (don.t care) | 1.3.6.1.4.1.6296.101.94.3.2.4 | TimeTicks | read-only | current |
| slePmCurrentControlReqResult OBJECT-TYPE Result of the last command. | 1.3.6.1.4.1.6296.101.94.3.2.5 | SleControlRequestResultType | read-only | current |
| slePmCurrentNotification OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.3.3 | |||
| slePMHistoryBase OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.4 | |||
| slePmHistoryTable OBJECT-TYPE This Table is used to for keeping the PM History | 1.3.6.1.4.1.6296.101.94.4.1 | not-accessible | current | |
| slePmHistoryEntry OBJECT-TYPE | 1.3.6.1.4.1.6296.101.94.4.1.1 | not-accessible | current | |
| slePmHistorySeqId OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.4.1.1.1 | INTEGER (1..65535) | read-only | current |
| slePmHistoryClassId OBJECT-TYPE History Class ID. | 1.3.6.1.4.1.6296.101.94.4.1.1.2 | PmClassId | read-only | current |
| slePmHistoryPmId OBJECT-TYPE History PM Id | 1.3.6.1.4.1.6296.101.94.4.1.1.3 | PmId | read-only | current |
| slePmHistoryPmSource OBJECT-TYPE |type|length|value|type|length|value|.... type (1-byte) : PM location type length(1-byte) : PM location value length value (length-bytes) : PM location value | 1.3.6.1.4.1.6296.101.94.4.1.1.4 | PmSrc | read-only | current |
| slePmHistoryTerm OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.4.1.1.5 | INTEGER {min15(1), day1(2)} | read-only | current |
| slePmHistoryIndex OBJECT-TYPE History Index: 15min : 1 ~ 96, 1-day : 1 ~ 7 | 1.3.6.1.4.1.6296.101.94.4.1.1.6 | INTEGER (1..31) | read-only | current |
| slePmHistoryPmCount OBJECT-TYPE History Performance count | 1.3.6.1.4.1.6296.101.94.4.1.1.7 | Counter64 | read-only | current |
| slePmHistoryAccCount OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.4.1.1.8 | Counter32 | read-write | current |
| slePmHistoryStartTime OBJECT-TYPE Description. | 1.3.6.1.4.1.6296.101.94.4.1.1.9 | TimeTicks | read-only | current |
| slePmHistoryControl OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.4.2 | |||
| slePmHistoryControlRequest OBJECT-TYPE The configuration commands, and user can configure functions via setting this entry as proper value. clearPmHistory : clears all the PM History Table | 1.3.6.1.4.1.6296.101.94.4.2.1 | INTEGER {clearPmHistory(1)} | read-write | current |
| slePmHistoryControlStatus OBJECT-TYPE status of user command. User have to check this value as .busy. or .idle. before do setRequest. | 1.3.6.1.4.1.6296.101.94.4.2.2 | SleControlStatusType | read-only | current |
| slePmHistoryControlTimer OBJECT-TYPE the wait-time until setRequest end. In case of short-time command, this value is 0 | 1.3.6.1.4.1.6296.101.94.4.2.3 | Gauge32 | read-write | current |
| slePmHistoryControlTimeStamp OBJECT-TYPE the time stamp of the last command. (don.t care) | 1.3.6.1.4.1.6296.101.94.4.2.4 | TimeTicks | read-only | current |
| slePmHistoryControlReqResult OBJECT-TYPE Result of the last command. | 1.3.6.1.4.1.6296.101.94.4.2.5 | SleControlRequestResultType | read-only | current |
| slePmHistoryNotification OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.94.4.3 |
Notifications
| Name | OID | Status |
|---|---|---|
| slePmConfigTcaEnableChanged NOTIFICATION-TYPE Notification for Tca Enable change | 1.3.6.1.4.1.6296.101.94.2.3.1 | current |
| slePmConfigTh15MinChanged NOTIFICATION-TYPE Notification for 15minute theshold change | 1.3.6.1.4.1.6296.101.94.2.3.2 | current |
| slePmConfigTh1DayChanged NOTIFICATION-TYPE Notification for 1day theshold change | 1.3.6.1.4.1.6296.101.94.2.3.3 | current |
| slePmCurrentPmCleared NOTIFICATION-TYPE Notification for current PM clear | 1.3.6.1.4.1.6296.101.94.3.3.1 | current |
| slePmHistoryPmCleared NOTIFICATION-TYPE Notification for PM History cleared | 1.3.6.1.4.1.6296.101.94.4.3.1 | current |