SLE-MPLS-TP-OAM-MIB
- Registered at
- 1.3.6.1.4.1.6296.101.16.17
- Last updated
- 2015-10-07 00:00
- Organization
- DASAN Networks
- Revisions
- 2013-01-08 00:00
- Namespace
- dasan
- Source file
SLE-MPLS-TP-OAM-MIB- Digest
sha256:0b75ce08e01b23813625d24b5f54840e95a6822bf99ba080175856602f2067df
Description
sleMpls
Contact
Gyerok Kwon Dasan Networks Email: grkwon@dasannetworks.com Kantharaj B M Dasan Networks Email: kanth@dasannetworks.com DongChel Shin (Chris) Dasan Networks Email: dchshin@dasannetworks.com Comments about this document should be emailed directly to the Dasan support email ID at support@dasannetworks.com.
Imports
| From | Symbols |
|---|---|
| DASAN-SMI | sleMgmt |
| IF-MIB | ifCounterDiscontinuityGroup, ifGeneralInformationGroup |
| MPLS-TC-STD-MIB | mplsStdMIB |
| SLE-TC-MIB | SleControlRequestResultType, SleControlStatusType |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, zeroDotZero |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
DASAN-SMI IANAifType-MIB IF-MIB MPLS-TC-STD-MIB SLE-MPLS-TP-OAM-MIB SLE-TC-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| sleMpls OBJECT-IDENTITY SLE MPLS. | 1.3.6.1.4.1.6296.101.16 | current | ||
| sleMplsTpOamMeg OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.17.1 | |||
| sleMplsTpOamMegInfoTable OBJECT-TYPE This table contains information about the Maintenance Entity Groups (MEG). MEG as mentioned in MPLS-TP OAM framework defines a set of one or more maintenance entities (ME). Maintenance Entities define a relationship between any two points of a transport path in an OAM domain to which maintenance and monitoring operations apply. | 1.3.6.1.4.1.6296.101.16.17.1.1 | read-only | current | |
| sleMplsTpOamMegInfoEntry OBJECT-TYPE An entry in this table represents MPLS-TP MEG. An entry can be created by a network administrator or by an SNMP agent as instructed by an MPLS-TP OAM Framework. When a new entry is created with sleMplsTpOamMegOperatorType set to ipCompatible (1), then as per [RFC6370] (MEG_ID for LSP is LSP_ID and MEG_ID for PW is PW_Path_ID), MEP_ID can be automatically formed. For co-routed bidirectional LSP, MEG_ID is A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID:: Node_ID::Tunnel_Num}::LSP_Num. For associated bidirectional LSP, MEG_ID is A1- {Global_ID::Node_ID::Tunnel_Num::LSP_Num}:: Z9- {Global_ID::Node_ID::Tunnel_Num::LSP_Num} For LSP, MEP_ID is formed using, Global_ID::Node_ID::Tunnel_Num::LSP_Num For PW, MEG_ID is formed using AGI::A1- {Global_ID::Node_ID::AC_ID}:: Z9- {Global_ID::Node_ID::AC_ID}. For PW, MEP_ID is formed using AGI::Global_ID::Node_ID::AC_ID MEP_ID is retrieved from the sleMplsTpOamMegServicePointer object based on the sleMplsTpOamMegServiceType value. ICC MEG_ID for LSP and PW is formed using the objects sleMplsTpOamMegIdIcc and sleMplsTpOamMegIdUmc. MEP_ID can be formed using MEG_ID::MEP_Index. | 1.3.6.1.4.1.6296.101.16.17.1.1.1 | read-only | current | |
| sleMplsTpOamMegInfoIndex OBJECT-TYPE Index for the conceptual row identifying a MEG within this MEG table. | 1.3.6.1.4.1.6296.101.16.17.1.1.1.1 | Unsigned32 (0..65535) | read-only | current |
| sleMplsTpOamMegInfoName OBJECT-TYPE Each Maintenance Entity Group has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each MEG. IETF : MEG Name Max. 48 characters long ITUT : MEG Name Max 5 characters(Excluding /). | 1.3.6.1.4.1.6296.101.16.17.1.1.1.2 | OCTET STRING (SIZE(1..48)) | read-only | current |
| sleMplsTpOamMegInfoOperatorType OBJECT-TYPE This object is used to set the IETF or ITUT. | 1.3.6.1.4.1.6296.101.16.17.1.1.1.3 | INTEGER {ietf(1), itut(2)} | read-only | current |
| sleMplsTpOamMegInfoServiceType OBJECT-TYPE Indicates the service type for which the MEG is created. If the service type indicates lsp, the service pointer in sleMplsOamMe points to the TE tunnel table entry. If the value is pseudowire service type, the service pointer in sleMplsOamMe points to the pseudowire table entry. If the value is section service type, the service pointer in sleMplsOamMe points to a section entry. | 1.3.6.1.4.1.6296.101.16.17.1.1.1.4 | INTEGER {tunnel(1), vc(2), datalink(3)} | read-only | current |
| sleMplsTpOamMegInfoMegLevel OBJECT-TYPE This variable is used to for level for ITUT. When a row in this table is in active object cannot be changed. | 1.3.6.1.4.1.6296.101.16.17.1.1.1.5 | INTEGER (0..7) | read-only | current |
| sleMplsTpOamMegInfoOperStatus OBJECT-TYPE This object specifies the operational status of the Maintenance Entity Group (MEG). This object is used to send the notification to the SNMP manager about the MEG. The value up (1) indicates that the MEG and its monitored path are operationally up. The value down (2) indicates that the MEG is operationally down. When the value of mplsOamIdMegOperStatus is up(1), all the bits of mplsOamIdMegSubOperStatus must be cleared. When the value of mplsOamIdMegOperStatus is down(2), at least one bit of mplsOamIdMegSubOperStatus must be set. | 1.3.6.1.4.1.6296.101.16.17.1.1.1.6 | INTEGER {up(1), down(2)} | read-only | current |
| sleMplsTpOamMegControl OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.17.1.2 | |||
| sleMplsTpOamMegControlRequest OBJECT-TYPE the configuration commands, and user can configure functions via setting this entry as proper value. | 1.3.6.1.4.1.6296.101.16.17.1.2.1 | INTEGER {createsleMplsTpOamMegControlEntry(1), deletesleMplsTpOamMegControlEntry(2), setsleMplsTpOamMegControlServiceType(3), setsleMplsTpOamMegControlLevel(4)} | read-write | current |
| sleMplsTpOamMegControlStatus OBJECT-TYPE status of user command. User have to check this value as .busy. or .idle. before do setRequest. | 1.3.6.1.4.1.6296.101.16.17.1.2.2 | SleControlStatusType | read-only | current |
| sleMplsTpOamMegControlTimer OBJECT-TYPE the wait-time until setRequest end. In case of short-time command, this value is 0 | 1.3.6.1.4.1.6296.101.16.17.1.2.3 | Gauge32 | read-write | current |
| sleMplsTpOamMegControlTimeStamp OBJECT-TYPE the time stamp of the last command. (don.t care) | 1.3.6.1.4.1.6296.101.16.17.1.2.4 | TimeTicks | read-only | current |
| sleMplsTpOamMegControlReqResult OBJECT-TYPE Result of the last command. | 1.3.6.1.4.1.6296.101.16.17.1.2.5 | SleControlRequestResultType | read-only | current |
| sleMplsTpOamMegControlName OBJECT-TYPE Each Maintenance Entity Group has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each MEG. | 1.3.6.1.4.1.6296.101.16.17.1.2.6 | OCTET STRING (SIZE(1..48)) | read-write | current |
| sleMplsTpOamMegControlOperatorType OBJECT-TYPE Indicates the operator type for MEG. Conceptual rows having 'iccBased' as operator type, should have valid values for the objects sleMplsTpOamMegControlIdIcc and sleMplsTpOamMegControlIdUmc while making the row status active. | 1.3.6.1.4.1.6296.101.16.17.1.2.7 | INTEGER {ietf(1), itut(2)} | read-write | current |
| sleMplsTpOamMegControlServiceType OBJECT-TYPE Indicates the service type for which the MEG is created. If the service type indicates lsp, the service pointer in sleMplsOamMe points to the TE tunnel table entry. If the value is pseudowire service type, the service pointer in sleMplsOamMe points to the pseudowire table entry. If the value is section service type, the service pointer in sleMplsOamMe points to a section entry. | 1.3.6.1.4.1.6296.101.16.17.1.2.8 | INTEGER {tunnel(1), vc(2), datalink(3)} | read-write | current |
| sleMplsTpOamMegControlLevel OBJECT-TYPE This variable is used to for level for ITUT. When a row in this table is in active object cannot be changed. | 1.3.6.1.4.1.6296.101.16.17.1.2.9 | INTEGER (0..7) | read-write | current |
| sleMplsTpOamMaintananceEntity OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.17.2 | |||
| sleMplsTpOamMaintanceEntityInfoTable OBJECT-TYPE This table contains MPLS-TP maintenance entity information. ME is some portion of a transport path that requires management bounded by two points (called MEPs), and the relationship between those points to which maintenance and monitoring operations apply. This table is generic enough to handle MEPs and MIPs information within a MEG. | 1.3.6.1.4.1.6296.101.16.17.2.1 | read-only | current | |
| sleMplsTpOamMaintanceEntityInfoEntry OBJECT-TYPE An entry in this table represents MPLS-TP maintenance entity. This entry represents the ME if the source and sink MEPs are defined. A ME is a p2p entity. One ME has two such MEPs. A MEG is a group of one or more MEs. One MEG can have two or more MEPs. For P2P LSP, one MEG has one ME and this ME is associated two MEPs (source and sink MEPs) within a MEG. Each sleMplsOamMeIndex value denotes the ME within a MEG. In case of unidirectional point-to-point transport paths, a single unidirectional Maintenance Entity is defined to monitor it and sleMplsOamMeServicePointer points to unidirectional point-to-point path. In case of associated bidirectional point-to-point transport paths, two independent unidirectional Maintenance Entities are defined to independently monitor each direction and each sleMplsOamMeServicePointer MIB object points to unique unidirectional transport path. This has implications for transactions that terminate at or query a MIP, as a return path from MIP to source MEP does not necessarily exist within the MEG. In case of co-routed bidirectional point-to-point transport paths, a single bidirectional Maintenance Entity is defined to monitor both directions congruently and sleMplsOamMeServicePointer MIB object points to co-routed bidirectional point-to-point transport path. In case of unidirectional point-to-multipoint transport paths, a single unidirectional Maintenance entity for each leaf is defined to monitor the transport path from the root to that leaf and each leaf has different transport path information in sleMplsOamMeServicePointer MIB object. | 1.3.6.1.4.1.6296.101.16.17.2.1.1 | read-only | current | |
| sleMplsTpOamMaintanceEntityInfoMeIndex OBJECT-TYPE Uniquely identifies a maintenance entity index within a MEG. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.1 | Unsigned32 (0..65535) | read-only | current |
| sleMplsTpOamMaintanceEntityInfoMpIndex OBJECT-TYPE Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.2 | Unsigned32 (1..8191) | not-accessible | current |
| sleMplsOamMaintenanceEntityInfoMeName OBJECT-TYPE This object denotes the ME name, each Maintenance Entity has unique name within MEG. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.3 | SnmpAdminString (SIZE(1..48)) | read-only | current |
| sleMplsTpOamMaintanceEntityInfoMpType OBJECT-TYPE Indicates the maintenance point type within the MEG. The object should have the value mep (1), only in the Ingress or Egress nodes of the transport path. The object can have the value mip (2), in the intermediate nodes and possibly in the end nodes of the transport path. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.4 | INTEGER {mep(1), mip(2)} | read-only | current |
| sleMplsOamMaintenanceEntityInfoServiceTunnelName OBJECT-TYPE This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.5 | OCTET STRING | read-only | current |
| sleMplsOamMaintenanceEntityInfoServiceVcId OBJECT-TYPE This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.6 | Unsigned32 | read-only | current |
| sleMplsOamMaintenanceEntityInfoServiceDatalink OBJECT-TYPE This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.7 | OCTET STRING | read-only | current |
| sleMplsTpOamMaintanceEntityInfoCcInterval OBJECT-TYPE This variable is used to keep the continuty check interval for ITUT. When a row in this table is in active object cannot be changed. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.8 | Unsigned32 (1..7) | read-only | current |
| sleMplsTpOamMaintanceEntityInfoRemoteMpId OBJECT-TYPE This variable is used for setting the remote mep id | 1.3.6.1.4.1.6296.101.16.17.2.1.1.9 | Unsigned32 (1..8191) | read-only | current |
| sleMplsTpOamMaintanceEntityInfoRemoteCc OBJECT-TYPE Global uniqueness is assured by concatenating the ICC with a Country Code (CC). The Country Code (alpha-2) is a string of two alphabetic characters represented with upper case letters (i.e., A-Z). This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.10 | OCTET STRING (SIZE(0..2)) | read-create | current |
| sleMplsTpOamMaintanceEntityInfoRemoteIcc OBJECT-TYPE Unique code assigned to Network Operator or Service Provider maintained by ITU-T. The ITU Carrier Code used to form MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.11 | OCTET STRING (SIZE(0..6)) | read-only | current |
| sleMplsTpOamMaintanceEntityInfoRemoteMeg OBJECT-TYPE Unique code assigned by Network Operator or Service Provider and is appended to mplsOamIdMegIdIcc to form the MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned. | 1.3.6.1.4.1.6296.101.16.17.2.1.1.12 | OCTET STRING (SIZE(0..6)) | read-only | current |
| sleMplsTpOamMaintanceEntityInfoRemoteMpdirection OBJECT-TYPE Indicates the maintenance point type within the MEG. This object is used to display the forward and reverse remote mep of Transist router . | 1.3.6.1.4.1.6296.101.16.17.2.1.1.13 | INTEGER {forward(1), reverse(2)} | read-only | current |
| sleMplsTpOamMaintanceEntityControl OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.17.2.2 | |||
| sleMplsTpOamMaintanceEntityRequest OBJECT-TYPE the configuration commands, and user can configure functions via setting this entry as proper value. | 1.3.6.1.4.1.6296.101.16.17.2.2.1 | INTEGER {createsleMplsTpOamMaintanceEntityControlEntry(1), deletesleMplsTpOamMaintanceEntityControlEntry(2), setsleMplsTpOamMaintanceEntityControlServiceValue(3), setSleMplsTpOamMepControlCCInterval(4), unsetSleMplsTpOamMepControlCCInterval(5), setsleMplsTpOamMaintanceEntityControlRmepId(6), unsetsleMplsTpOamMaintanceEntityControlRmepId(7)} | read-write | current |
| sleMplsTpOamMaintanceEntityControlStatus OBJECT-TYPE status of user command. User have to check this value as .busy. or .idle. before do setRequest. | 1.3.6.1.4.1.6296.101.16.17.2.2.2 | SleControlStatusType | read-only | current |
| sleMplsTpOamMaintanceEntityControlTimer OBJECT-TYPE the wait-time until setRequest end. In case of short-time command, this value is 0 | 1.3.6.1.4.1.6296.101.16.17.2.2.3 | Gauge32 | read-write | current |
| sleMplsTpOamMaintanceEntityControlTimeStamp OBJECT-TYPE the time stamp of the last command. (don.t care) | 1.3.6.1.4.1.6296.101.16.17.2.2.4 | TimeTicks | read-only | current |
| sleMplsTpOamMaintanceEntityControlReqResult OBJECT-TYPE Result of the last command. | 1.3.6.1.4.1.6296.101.16.17.2.2.5 | SleControlRequestResultType | read-only | current |
| sleMplsTpOamMaintanceEntityControlMegName OBJECT-TYPE Uniquely identifies a maintenance entity index within a MEG. | 1.3.6.1.4.1.6296.101.16.17.2.2.6 | OCTET STRING | read-write | current |
| sleMplsTpOamMaintanceEntityControlMeName OBJECT-TYPE This object denotes the ME name, each Maintenance Entity has unique name within MEG. | 1.3.6.1.4.1.6296.101.16.17.2.2.7 | OCTET STRING (SIZE(1..48)) | read-write | current |
| sleMplsTpOamMaintanceEntityControlMepId OBJECT-TYPE Uniquely identifies a maintenance entity index within a MEP . | 1.3.6.1.4.1.6296.101.16.17.2.2.8 | Unsigned32 (1..8191) | read-write | current |
| sleMplsTpOamMaintanceEntityControlMpType OBJECT-TYPE Indicates the maintenance point type within the MEG. The object should have the value mep (1), only in the Ingress or Egress nodes of the transport path. The object can have the value mip (2), in the intermediate nodes and possibly in the end nodes of the transport path. | 1.3.6.1.4.1.6296.101.16.17.2.2.9 | INTEGER {mep(1), mip(2)} | read-write | current |
| sleMplsTpOamMaintanceEntityControlServiceValue OBJECT-TYPE This variable represents a pointer to the MPLS-TP transport path. This value may point at an entry in the sleMplsTunnelEntry if sleMplsOamMeControlgServiceType is configured as lsp (1) or at an entry in the pwEntry if sleMplsOamMeControlgServiceType is configured as pseudowire (2). Note: This service pointer object, is placed in ME table instead of MEG table, since it will be useful in case of point-to-multipoint, where each ME will point to different branches of a P2MP tree. | 1.3.6.1.4.1.6296.101.16.17.2.2.10 | OCTET STRING | read-write | current |
| sleMplsTpOamMaintanceEntityControlCcInterval OBJECT-TYPE This variable is used to keep the continuty check interval for ITUT. When a row in this table is in active object cannot be changed. | 1.3.6.1.4.1.6296.101.16.17.2.2.11 | Unsigned32 (1..7) | read-write | current |
| sleMplsTpOamMaintanceEntityControlRemoteMpId OBJECT-TYPE This variable is used for setting the remote mep id | 1.3.6.1.4.1.6296.101.16.17.2.2.12 | Unsigned32 (1..8191) | read-only | current |
| sleMplsTpOamMaintanceEntityControlRemoteCc OBJECT-TYPE Global uniqueness is assured by concatenating the ICC with a Country Code (CC). The Country Code (alpha-2) is a string of two alphabetic characters represented with upper case letters (i.e., A-Z). This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned. | 1.3.6.1.4.1.6296.101.16.17.2.2.13 | OCTET STRING (SIZE(0..2)) | read-write | current |
| sleMplsTpOamMaintanceEntityControlRemoteIcc OBJECT-TYPE Unique code assigned to Network Operator or Service Provider maintained by ITU-T. The ITU Carrier Code used to form MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned. | 1.3.6.1.4.1.6296.101.16.17.2.2.14 | OCTET STRING (SIZE(0..6)) | read-write | current |
| sleMplsTpOamMaintanceEntityControlRemoteMeg OBJECT-TYPE Unique code assigned by Network Operator or Service Provider and is appended to mplsOamIdMegIdIcc to form the MEGID. This object MUST contain a non-null ICC value if the MplsOamIdMegOperatorType value is iccBased(2), otherwise a null ICC value with octet size 0 should be assigned. | 1.3.6.1.4.1.6296.101.16.17.2.2.15 | OCTET STRING (SIZE(0..7)) | read-write | current |
| sleMplsTpOamMaintanceEntityControlRemoteMpDirection OBJECT-TYPE Indicates the direction of the MEP. This object should be configured if sleMplsOamMeControlMpType is configured as mep (1). | 1.3.6.1.4.1.6296.101.16.17.2.2.16 | INTEGER {fwd(1), rev(2)} | read-write | current |
| sleMplsTpOamFm OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.17.3 | |||
| sleMplsTpOamFmInfoTable OBJECT-TYPE | 1.3.6.1.4.1.6296.101.16.17.3.1 | read-only | current | |
| sleMplsTpOamFmInfoEntry OBJECT-TYPE An entry in this table represents MPLS-TP maintenance entity. | 1.3.6.1.4.1.6296.101.16.17.3.1.1 | read-only | current | |
| sleMplsTpOamFmInfoMeIndex OBJECT-TYPE Uniquely identifies a maintenance entity index within a MEG. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.1 | Unsigned32 (0..65535) | read-only | current |
| sleMplsTpOamFmInfoMpIndex OBJECT-TYPE Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.2 | Unsigned32 (1..8191) | not-accessible | current |
| sleMplsTpOamFmInfoFaultManagement OBJECT-TYPE Fault Managment for IETF shows enable or disable | 1.3.6.1.4.1.6296.101.16.17.3.1.1.3 | INTEGER {enable(1), disable(2)} | read-only | current |
| sleMplsTpOamFmInfoRefreshTime OBJECT-TYPE This Object is used in IETF-based Fault Management RefreshTimer. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.4 | Unsigned32 (1..20) | read-only | current |
| sleMplsTpOamFmInfoLockInstruct OBJECT-TYPE Lock instruct for IETF shows enable or disable | 1.3.6.1.4.1.6296.101.16.17.3.1.1.5 | INTEGER {enable(1), disable(2)} | read-only | current |
| sleMplsTpOamFmInfoLockInstructRefreshTime OBJECT-TYPE This Object is used in IETF-based lock RefreshTimer. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.6 | Unsigned32 (1..20) | read-only | current |
| sleMplsTpOamFmInfoAlarmIndication OBJECT-TYPE Alarm indication for ITUT shows enable or disable. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.7 | INTEGER {enable(1), disable(2)} | read-only | current |
| sleMplsTpOamFmInfoAlarmIndicationInterval OBJECT-TYPE This is object to display the itut alarm indication interval value. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.8 | INTEGER {oneSecond(1), sixtySeconds(2)} | read-only | current |
| sleMplsTpOamFmInfoAlarmIndicationLevel OBJECT-TYPE This object to display the Itut alarm indication Level value. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.9 | INTEGER (0..7) | read-only | current |
| sleMplsTpOamFmInfoLock OBJECT-TYPE This Object is used in ITUT-based lock. This object will enable/disable the lock | 1.3.6.1.4.1.6296.101.16.17.3.1.1.10 | INTEGER {enable(1), disable(2)} | read-only | current |
| sleMplsTpOamFmInfoLockInterval OBJECT-TYPE This object is used to display the ITUT based Lock Interval. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.11 | INTEGER {oneSecond(1), sixtySeconds(2)} | read-only | current |
| sleMplsTpOamFmInfoLockLevel OBJECT-TYPE This object is used to Display the ITUT based Lock Level. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.12 | INTEGER (0..7) | read-only | current |
| sleMplsTpOamFmInfoLoopBack OBJECT-TYPE This Object is used in IETF-based loop back. This will show enable/disable loop back . | 1.3.6.1.4.1.6296.101.16.17.3.1.1.13 | INTEGER {enable(1), disable(2)} | read-only | current |
| sleMplsTpOamFmInfoLoopBackStatus OBJECT-TYPE This object to display the Status of IETF Based LoopBackStatus. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.14 | INTEGER {up(1), down(2)} | read-only | current |
| sleMplsTpOamFmInfoLockInstructStatus OBJECT-TYPE This object to display the Status of IETF Based LockInstruct. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.15 | INTEGER {up(1), down(2)} | read-only | current |
| sleMplsTpOamFmInfoFaultManagementStatus OBJECT-TYPE This object to display the Status of IETF Based FaultManagement. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.16 | INTEGER {up(1), down(2)} | read-only | current |
| sleMplsTpOamFmInfoCcCvStatus OBJECT-TYPE This object to display the Status of IETF Based CC-CV. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.17 | INTEGER {enabled(1), disabled(2)} | read-only | current |
| sleMplsTpOamFmInfoStatus OBJECT-TYPE This object is used to display the IETF Status 1- path not Associated. 2- path associated with another me. 3- path down 4- received AIS Message. 5- received LKR FM Message. 6- Bfd Detected Loc. 7- Server Layer Down. 8- Invalid Me. | 1.3.6.1.4.1.6296.101.16.17.3.1.1.18 | INTEGER {pathNotAssociated(1), pathAssociateWithAnotherMe(2), pathDown(3), receivedAisFmMessage(4), receviedLkrFmMessage(5), bfdDetecLoc(6), serverLayerDown(7), invalidMe(8)} | read-only | current |
| sleMplsTpOamFmControlTable OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.17.3.2 | |||
| sleMplsTpOamFmControlRequest OBJECT-TYPE the configuration commands, and user can configure functions via setting this entry as proper value. | 1.3.6.1.4.1.6296.101.16.17.3.2.1 | INTEGER {setSleMplsTpOamFmControlInit(1), unsetSleMplsTpOamFmControlInit(2), setSleMplsTpOamItutAis(3), unsetSleMplsTpOamItutAis(4), setSleMplsTpOamItutLockInterval(5), unsetSleMplsTpOamItutLockInterval(6)} | read-write | current |
| sleMplsTpOamFmControlStatus OBJECT-TYPE status of user command. User have to check this value as .busy. or .idle. before do setRequest. | 1.3.6.1.4.1.6296.101.16.17.3.2.2 | SleControlStatusType | read-only | current |
| sleMplsTpOamFmControlTimer OBJECT-TYPE the wait-time until setRequest end. In case of short-time command, this value is 0 | 1.3.6.1.4.1.6296.101.16.17.3.2.3 | Gauge32 | read-write | current |
| sleMplsTpOamFmControlTimeStamp OBJECT-TYPE the time stamp of the last command. (don.t care) | 1.3.6.1.4.1.6296.101.16.17.3.2.4 | TimeTicks | read-only | current |
| sleMplsTpOamFmControlReqResult OBJECT-TYPE Result of the last command. | 1.3.6.1.4.1.6296.101.16.17.3.2.5 | SleControlRequestResultType | read-only | current |
| sleMplsTpOamFmControlMegName OBJECT-TYPE Uniquely identifies a maintenance entity index within a MEG. | 1.3.6.1.4.1.6296.101.16.17.3.2.6 | OCTET STRING | read-write | current |
| sleMplsTpOamFmControlMeName OBJECT-TYPE Uniquely identifies a maintenance entity index within a ME. | 1.3.6.1.4.1.6296.101.16.17.3.2.7 | OCTET STRING | read-write | current |
| sleMplsTpOamFmControlMepId OBJECT-TYPE Uniquely identifies a maintenance entity index within a MEP. | 1.3.6.1.4.1.6296.101.16.17.3.2.8 | Unsigned32 (1..8191) | read-write | current |
| sleMplsTpOamFmInit OBJECT-TYPE This variable is used for setting the fault Measurments for IETF/ITUT based upon gloable configuration 1) Fault measurment is for IETF 2) Lock-Instruct is for IETF 3) LoopBack to configure for IETF | 1.3.6.1.4.1.6296.101.16.17.3.2.9 | INTEGER {faultMeasurment(1), lockInstruct(2), loopBack(3)} | read-write | current |
| sleMplsTpOamFmControlRefreshTime OBJECT-TYPE This varible is used to set the Refresh Time for IETF of 2 objects ie., Fault managment and Lock Instruct 1) Fault managment range (1-20) 2) Lock-Instruct range (1-255) | 1.3.6.1.4.1.6296.101.16.17.3.2.10 | Unsigned32 (1..255) | read-write | current |
| sleMplsTpOamFmControlInterval OBJECT-TYPE This variable is used to set the interval for 2 alarm-inidaction and lock objects of ITUT | 1.3.6.1.4.1.6296.101.16.17.3.2.11 | INTEGER {oneOne(1), sixtyOne(2)} | read-write | current |
| sleMplsTpOamFmControlLevel OBJECT-TYPE This varible is used to set the level for Alarm indication and lock objects of ITUT | 1.3.6.1.4.1.6296.101.16.17.3.2.12 | INTEGER (0..7) | read-write | current |