SLE-MPLS-TP-NODE-MIB
- Registered at
- 1.3.6.1.4.1.6296.101.16.13
- Last updated
- 2015-10-07 00:00
- Organization
- Multiprotocol Label Switching (MPLS) Working Group
- Revisions
- 2012-07-15 00:00
- Namespace
- dasan
- Source file
SLE-MPLS-TP-NODE-MIB- Digest
sha256:4a3520c0d52022c68b7b9abb46b8cb9d98d60c6c0e5130e2198c4e1543ad3ac7
Description
Copyright (c) 2012 IETF Trust and the persons identified as the document authors. All rights reserved. This MIB module contains generic object definitions for MPLS Traffic Engineering in transport networks.
Contact
Gyerok Kwon Dasan Networks Email: grkwon@dasannetworks.com Kantharaj B M Dasan Networks Email: kanth@dasannetworks.com DongChel Shin (Chris) Dasan Networks Email: dchshin@dasannetworks.com Comments about this document should be emailed directly to the Dasan support email ID at support@dasannetworks.com.
Imports
| From | Symbols |
|---|---|
| DASAN-SMI | sleMgmt |
| MPLS-TC-EXT-STD-MIB | MplsCcId, MplsIccId |
| MPLS-TE-STD-MIB | mplsTunnelEgressLSRId, mplsTunnelIndex, mplsTunnelIngressLSRId, mplsTunnelInstance |
| SLE-TC-MIB | SleControlRequestResultType, SleControlStatusType |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, zeroDotZero |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
DASAN-SMI DIFFSERV-DSCP-TC DIFFSERV-MIB IANAifType-MIB IF-MIB INET-ADDRESS-MIB INTEGRATED-SERVICES-MIB MPLS-TC-EXT-STD-MIB MPLS-TC-STD-MIB MPLS-TE-STD-MIB SLE-MPLS-TP-NODE-MIB SLE-TC-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6296.101.16.13.2 | sleMplsTpProIf | SLE-MPLS-TP-PRO-IF-MIB |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| sleMpls OBJECT-IDENTITY SLE MPLS. | 1.3.6.1.4.1.6296.101.16 | current | ||
| sleMplsTpNodeCfg OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.13.1 | |||
| sleMplsTpNodeCfgInfo OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.13.1.1 | |||
| sleMplsTpNodeCfgInfoGlobalId OBJECT-TYPE This object indicates the Global Operator Identifier. this object value should be zero when sleMplsTpNodeConfigInfoCcId and sleMplsTpNodeConfigInfoICcId is configured with non-null value. | 1.3.6.1.4.1.6296.101.16.13.1.1.1 | Unsigned32 (1..4294967295) | read-only | current |
| sleMplsTpNodeCfgInfoItutCc OBJECT-TYPE This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value. | 1.3.6.1.4.1.6296.101.16.13.1.1.2 | MplsCcId | read-only | current |
| sleMplsTpNodeCfgInfoItutIcc OBJECT-TYPE This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value. | 1.3.6.1.4.1.6296.101.16.13.1.1.3 | MplsIccId | read-only | current |
| sleMplsTpNodeCfgInfoNodeId OBJECT-TYPE This object indicates the Node_ID within the operator. | 1.3.6.1.4.1.6296.101.16.13.1.1.4 | IpAddress | read-only | current |
| sleMplsTpNodeCfgInfoNodeType OBJECT-TYPE This object value should be zero when sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value . | 1.3.6.1.4.1.6296.101.16.13.1.1.5 | INTEGER {ietf(1), itut(2)} | read-only | current |
| sleMplsTpNodeCfgControl OBJECT-IDENTITY | 1.3.6.1.4.1.6296.101.16.13.1.2 | |||
| sleMplsTpNodeCfgControlRequest OBJECT-TYPE This object holds the possible read-write columns that can be modified in the TunnelExtNodeConfigTable table. For each read-write column of TunnelExtNodeConfigTable table, a Set Operation control value is added in this object. | 1.3.6.1.4.1.6296.101.16.13.1.2.1 | INTEGER {setMplsTpNode(1), unsetMplsTpNode(2)} | read-write | current |
| sleMplsTpNodeCfgControlStatus OBJECT-TYPE This object displays the status of the configuration done. | 1.3.6.1.4.1.6296.101.16.13.1.2.2 | SleControlStatusType | read-only | current |
| sleMplsTpNodeCfgControlTimer OBJECT-TYPE This object is based on the SLE style where a timer is configured for every control table. | 1.3.6.1.4.1.6296.101.16.13.1.2.3 | Gauge32 | read-write | current |
| sleMplsTpNodeCfgControlTimestamp OBJECT-TYPE This object specifies the time at which the configuration is done. | 1.3.6.1.4.1.6296.101.16.13.1.2.4 | TimeTicks | read-only | current |
| sleMplsTpNodeCfgControlReqResult OBJECT-TYPE The standard result of the SET operation is stored here. | 1.3.6.1.4.1.6296.101.16.13.1.2.5 | SleControlRequestResultType | read-only | current |
| sleMplsTpNodeCfgControlGlobalId OBJECT-TYPE This object indicates the Global Operator Identifier. This object value should be zero when sleMplsTpNodeConfigControlIccId and sleMplsTpNodeConfigControlccId is configured with non-null value. | 1.3.6.1.4.1.6296.101.16.13.1.2.6 | Unsigned32 (1..4294967295) | read-write | current |
| sleMplsTpNodeCfgControlItutCc OBJECT-TYPE This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigControlGlobalId are assigned with non-zero value. | 1.3.6.1.4.1.6296.101.16.13.1.2.7 | MplsCcId | read-write | current |
| sleMplsTpNodeCfgControlItutIcc OBJECT-TYPE This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when sleMplsTpNodeConfigControlGlobalId are assigned with non-zero value. | 1.3.6.1.4.1.6296.101.16.13.1.2.8 | MplsIccId | read-write | current |
| sleMplsTpNodeCfgControlNodeId OBJECT-TYPE This object indicates the Node_ID within the operator. | 1.3.6.1.4.1.6296.101.16.13.1.2.9 | IpAddress | read-write | current |
| sleMplsTpNodeCfgControlNodeType OBJECT-TYPE This object allows the operator or service provider to configure a unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID or Egress ID. This object value should be zero when msleMplsTpNodeConfigControlGlobalId are assigned with non-zero value. | 1.3.6.1.4.1.6296.101.16.13.1.2.10 | INTEGER {ietf(1), itut(2)} | read-write | current |