MIBs Depot

SLE-MPLS-TP-BFD-MIB

Registered at
1.3.6.1.4.1.6296.101.16.19
Last updated
2015-10-07 00:00
Organization
Dasan Networks
Revisions
2004-06-03 00:00
Namespace
dasan
Source file
SLE-MPLS-TP-BFD-MIB
Digest
sha256:0a8cac2b1e937c417a2a2088b042f151792f3a45e8f60be76c728ca6b910172b

Description

Bidirectional Forwarding Management Information Base.

Contact

Gyerok Kwon Dasan Networks Email: grkwon@dasannetworks.com Kantharaj B M Dasan Networks Email: kanth@dasannetworks.com DongChel Shin (Chris) Dasan Networks Email: dchshin@dasannetworks.com Comments about this document should be emailed directly to the Dasan support email ID at support@dasannetworks.com.

Imports

FromSymbols
DASAN-SMIsleMgmt
IANA-BFD-TC-STD-MIBIANAbfdDiagTC
SLE-TC-MIBSleControlRequestResultType, SleControlStatusType
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, mib-2
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DASAN-SMI
IANA-BFD-TC-STD-MIB
SLE-MPLS-TP-BFD-MIB
SLE-TC-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
sleMpls
OBJECT-IDENTITY
SLE MPLS.
1.3.6.1.4.1.6296.101.16current
sleMplsTpBfdCfg
OBJECT-IDENTITY
1.3.6.1.4.1.6296.101.16.19.1
sleMplsTpBfdCfgInfoTable
OBJECT-TYPE
The BFD Cfg Table describes the configuration details.
1.3.6.1.4.1.6296.101.16.19.1.1read-onlycurrent
sleMplsTpBfdCfgInfoEntry
OBJECT-TYPE
The BFD Session Entry describes BFD session.
1.3.6.1.4.1.6296.101.16.19.1.1.1read-onlycurrent
sleMplsTpBfdCfgInfoMegIndex
OBJECT-TYPE
MEG Index.
1.3.6.1.4.1.6296.101.16.19.1.1.1.1Unsigned32 (1..65535)not-accessiblecurrent
sleMplsTpBfdCfgInfoMeIndex
OBJECT-TYPE
Maintenance Entity Index.
1.3.6.1.4.1.6296.101.16.19.1.1.1.2Unsigned32 (1..65535)not-accessiblecurrent
sleMplsTpBfdCfgInfoMegName
OBJECT-TYPE
MEG Index.
1.3.6.1.4.1.6296.101.16.19.1.1.1.3OCTET STRINGread-onlycurrent
sleMplsTpBfdCfgInfoMeName
OBJECT-TYPE
Maintenance Entity Index.
1.3.6.1.4.1.6296.101.16.19.1.1.1.4OCTET STRINGread-onlycurrent
sleMplsTpBfdCfgInfoTxInterval
OBJECT-TYPE
TX Packet Interval of BFD to neighbor.
1.3.6.1.4.1.6296.101.16.19.1.1.1.5OCTET STRINGread-onlycurrent
sleMplsTpBfdCfgInfoRXInterval
OBJECT-TYPE
RX Packet Interval of BFD from neighbor.
1.3.6.1.4.1.6296.101.16.19.1.1.1.6OCTET STRINGread-onlycurrent
sleMplsTpBfdCfgControl
OBJECT-IDENTITY
1.3.6.1.4.1.6296.101.16.19.1.2
sleMplsTpBfdCfgControlRequest
OBJECT-TYPE
This object holds the possible read-write columns that can be modified in the BFD Config table. For each read-write column of BFD config table, a Set Operation control value is added in this object.
1.3.6.1.4.1.6296.101.16.19.1.2.1INTEGER {createBfdcfgEntry(1), deleteBfdCfgEntry(2), setIntervals(3)}read-writecurrent
sleMplsTpBfdCfgControlStatus
OBJECT-TYPE
This object displays the status of the configuration done.
1.3.6.1.4.1.6296.101.16.19.1.2.2SleControlStatusTyperead-onlycurrent
sleMplsTpBfdCfgControlTimer
OBJECT-TYPE
This object is based on the SLE style where a timer is configured for every control table.
1.3.6.1.4.1.6296.101.16.19.1.2.3Gauge32read-writecurrent
sleMplsTpBfdCfgControlTimestamp
OBJECT-TYPE
This object specifies the time at which the configuration is done.
1.3.6.1.4.1.6296.101.16.19.1.2.4TimeTicksread-onlycurrent
sleMplsTpBfdCfgControlReqResult
OBJECT-TYPE
The standard result of the SET operation is stored here.
1.3.6.1.4.1.6296.101.16.19.1.2.5SleControlRequestResultTyperead-onlycurrent
sleMplsTpBfdCfgControlMegName
OBJECT-TYPE
MEG Name.
1.3.6.1.4.1.6296.101.16.19.1.2.6OCTET STRINGnot-accessiblecurrent
sleMplsTpBfdCfgControlMeName
OBJECT-TYPE
Maintenance Entity Name.
1.3.6.1.4.1.6296.101.16.19.1.2.7OCTET STRINGread-writecurrent
sleMplsTpBfdCfgControlTxInterval
OBJECT-TYPE
TX Packet Interval of BFD to neighbor.
1.3.6.1.4.1.6296.101.16.19.1.2.8OCTET STRINGread-writecurrent
sleMplsTpBfdCfgControlRXInterval
OBJECT-TYPE
RX Packet Interval of BFD from neighbor.
1.3.6.1.4.1.6296.101.16.19.1.2.9OCTET STRINGread-writecurrent
sleMplsTpBfdSession
OBJECT-IDENTITY
1.3.6.1.4.1.6296.101.16.19.2
sleMplsTpBfdSessionInfoTable
OBJECT-TYPE
The BFD Session Table describes the BFD sessions.
1.3.6.1.4.1.6296.101.16.19.2.1read-onlycurrent
sleMplsTpBfdSessionInfoEntry
OBJECT-TYPE
The BFD Session Entry describes BFD session.
1.3.6.1.4.1.6296.101.16.19.2.1.1read-onlycurrent
sleMplsTpBfdSessionInfoSessIndex
OBJECT-TYPE
This object contains an index used to represent a unique BFD session on this device.
1.3.6.1.4.1.6296.101.16.19.2.1.1.1Unsigned32 (1..65535)not-accessiblecurrent
sleMplsTpBfdSessionInfoMegName
OBJECT-TYPE
MEG Name of the BFD Session.
1.3.6.1.4.1.6296.101.16.19.2.1.1.2OCTET STRINGread-onlycurrent
sleMplsTpBfdSessionInfoMeName
OBJECT-TYPE
MEG Name of the BFD Session.
1.3.6.1.4.1.6296.101.16.19.2.1.1.3OCTET STRINGread-onlycurrent
sleMplsTpBfdSessionInfoVersionNumber
OBJECT-TYPE
The version number of the BFD protocol that this session is running in. Write access is available for this object to provide ability to set desired version for this BFD session.
1.3.6.1.4.1.6296.101.16.19.2.1.1.4Unsigned32 (0..7)read-onlycurrent
sleMplsTpBfdSessionInfoDiscriminator
OBJECT-TYPE
This object specifies the local discriminator for this BFD session, used to uniquely identify it.
1.3.6.1.4.1.6296.101.16.19.2.1.1.5Unsigned32 (1..4294967295)read-onlycurrent
sleMplsTpBfdSessionInfoRemoteDiscriminator
OBJECT-TYPE
This object specifies the session discriminator chosen by the remote system for this BFD session. The value may be zero(0) if the remote discriminator is not yet known or if the session is in the down or adminDown(1) state.
1.3.6.1.4.1.6296.101.16.19.2.1.1.6Unsigned32 (0 | 1..4294967295)read-onlycurrent
sleMplsTpBfdSessionInfoState
OBJECT-TYPE
BFD session state.
1.3.6.1.4.1.6296.101.16.19.2.1.1.7INTEGER {adminDown(0), stateDown(1), stateInit(2), stateUp(3), unknown(4)}read-onlycurrent
sleMplsTpBfdSessionInfoDiag
OBJECT-TYPE
A diagnostic code specifying the local system's reason for the last transition of the session from up(4) to some other state.
1.3.6.1.4.1.6296.101.16.19.2.1.1.8IANAbfdDiagTCread-onlycurrent
sleMplsTpBfdSessionInfoDesiredMinTxInterval
OBJECT-TYPE
This object specifies the minimum interval, in microseconds, that the local system would like to use when transmitting BFD Control packets. The value of zero(0) is reserved, and should not be used.
1.3.6.1.4.1.6296.101.16.19.2.1.1.9OCTET STRINGread-onlycurrent
sleMplsTpBfdSessionInfoReqMinRxInterval
OBJECT-TYPE
This object specifies the minimum interval, in microseconds, between received BFD Control packets the local system is capable of supporting. The value of zero(0) can be specified when the transmitting system does not want the remote system to send any periodic BFD control packets.
1.3.6.1.4.1.6296.101.16.19.2.1.1.10OCTET STRINGread-onlycurrent
sleMplsTpBfdSessionInfoDetectMult
OBJECT-TYPE
1.3.6.1.4.1.6296.101.16.19.2.1.1.11Unsigned32read-onlycurrent