MIBs Depot

SL-EDFA-MIB

Registered at
1.3.6.1.4.1.4515.1.9
Last updated
2002-02-04 00:00
Organization
PacketLight Networks Ltd.
Namespace
packetlight
Source file
SL-EDFA-MIB
Digest
sha256:a21da7c640e7b1332ca74e636ee9ce6a5eb06daa0400e2f483c31019b23b2e79

Description

This MIB module describes the EDFA Cards

Contact

Omri_Viner@PacketLight.com

Imports

FromSymbols
IF-MIBInterfaceIndex
PerfHist-TC-MIBPerfCurrentCount, PerfIntervalCount, PerfTotalCount
SL-NE-MIBsitelight
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp, TruthValue

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
PerfHist-TC-MIB
SL-EDFA-MIB
SL-NE-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
edfaConfig
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.9.1
edfaConfigTable
OBJECT-TYPE
The EDFA configuration table.
1.3.6.1.4.1.4515.1.9.1.1not-accessiblecurrent
edfaConfigEntry
OBJECT-TYPE
An entry in the EDFA interface configuration table. The index to this table is the same as the an ifIndex.
1.3.6.1.4.1.4515.1.9.1.1.1not-accessiblecurrent
edfaIfIndex
OBJECT-TYPE
The amplifier interface index.
1.3.6.1.4.1.4515.1.9.1.1.1.1InterfaceIndexread-onlycurrent
edfaPumpTemp
OBJECT-TYPE
The pump temperture (in Kelvin).
1.3.6.1.4.1.4515.1.9.1.1.1.2Integer32read-onlycurrent
edfaRxPower
OBJECT-TYPE
The measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm).
1.3.6.1.4.1.4515.1.9.1.1.1.3INTEGERread-onlycurrent
edfaPumpAdminStatus
OBJECT-TYPE
The desired state of the laser. The restart(3) state indicates that the edfa pump should be restarted. The restart(3) is not a state, thus it is not kept in the configuration file.
1.3.6.1.4.1.4515.1.9.1.1.1.4INTEGER {up(1), down(2), restart(3)}read-writecurrent
edfaPumpOperStatus
OBJECT-TYPE
The current operational state of the laser. If edfaPumpAdminStatus is down(2) then edfaPumpOperStatus should be down(2). If edfaPumpAdminStatus is changed to up(1) then edfaPumpOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic; it should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state. The operational status is equal to restart(3) if the edfa pump is still in restart process.
1.3.6.1.4.1.4515.1.9.1.1.1.5INTEGER {up(1), down(2), restart(3), unknown(4)}read-onlycurrent
edfaStatus
OBJECT-TYPE
This variable indicates the Line Status of the Edfa module. The edfaStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. edfaNoAlarm must be set if and only if no other flag is set. The various bit positions are: 1 edfaNoAlarm No alarm present 2 edfaPumpTemperuture Pump temperatur is out-of-bound 4 edfaPumpWavelength Pump wavelength is out-of-bound 8 edfaHwFail Pump HW failure 16 edfaRvcSignalDetect Loss of input signal 32 edfaPumpPower Pump power is out-of-bound 64 edfaRcvPower Rx Power is out-of-bound 128 edfaTemprature Edfa temperature is out-of-bound 256 edfaEyeSafty Eye safety alarm (available only in eye-safety mode) 512 edafGainFlatness Gain flatness alarm 1024 edfaXmtPower Tx Power is out-of-bound 2048 edfaGain Edfa Gain is out-of-bound 4096 edfaEol Pump End Of Life
1.3.6.1.4.1.4515.1.9.1.1.1.6INTEGER (1..8191)read-onlycurrent
edfaVoa
OBJECT-TYPE
The computed VOA output attenuation specified in 0.1 dB units. From 0.0 to +15.0 dB.
1.3.6.1.4.1.4515.1.9.1.1.1.7INTEGERread-onlycurrent
edfaAutomaticMode
OBJECT-TYPE
Defines the Edfa automatic mode. If equals TRUE, the Edfa control mode should selected automaticaly. Otherwise it should be selected manualy.
1.3.6.1.4.1.4515.1.9.1.1.1.8TruthValueread-writecurrent
edfaAdminControlMode
OBJECT-TYPE
Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.
1.3.6.1.4.1.4515.1.9.1.1.1.9INTEGER {apc(1), agc(2)}read-writecurrent
edfaOperControlMode
OBJECT-TYPE
The current Edfa control mode. Initialy the Edfa starts in APC mode. The AGC mode is used only when selected manualy or after transient input power change.
1.3.6.1.4.1.4515.1.9.1.1.1.10INTEGER {apc(1), agc(2)}read-onlycurrent
edfaAdminGain
OBJECT-TYPE
The required Edfa Gain value given in 0.1 dB units. This value may be configured only when the edfa automatic mode is FALSE and the edfa control mode is Agc.
1.3.6.1.4.1.4515.1.9.1.1.1.11INTEGERread-writecurrent
edfaOperGain
OBJECT-TYPE
The actual Edfa Gain value given in 0.1 dB units. Value range starts with 0.0 dbm
1.3.6.1.4.1.4515.1.9.1.1.1.12INTEGERread-onlycurrent
edfaAdminOutputPower
OBJECT-TYPE
The required Edfa output power value given in 0.1 dBm units. The range starts with -30.0 dBm. This value may be configured only when the edfa control mode is Apc.
1.3.6.1.4.1.4515.1.9.1.1.1.13INTEGERread-writecurrent
edfaOperOutputPower
OBJECT-TYPE
The actual Edfa output power value specified in 0.1 dBm units. Valid valuse are in the range of 0.0 dBm upto +15.0 dBm.
1.3.6.1.4.1.4515.1.9.1.1.1.14INTEGERread-onlycurrent
edfaChannelsNumber
OBJECT-TYPE
The number of optical channels on this signal.
1.3.6.1.4.1.4515.1.9.1.1.1.15INTEGERread-onlycurrent
edfaTotalChannelsNumber
OBJECT-TYPE
The total number of optical channels on this fiber.
1.3.6.1.4.1.4515.1.9.1.1.1.16INTEGERread-onlycurrent
edfaEyeSafetyMode
OBJECT-TYPE
When in Eye-Safety mode the edfa reduces the laser power budget down to safe level upon detection of an output fiber cut.
1.3.6.1.4.1.4515.1.9.1.1.1.17TruthValueread-writecurrent
edfaShutDownLipEnable
OBJECT-TYPE
EDFA shout-down on LIP (Loss of signal) - enable/disable.
1.3.6.1.4.1.4515.1.9.1.1.1.18TruthValueread-writecurrent
edfaAutoPowerUpLipEnable
OBJECT-TYPE
EDFA automatic power up (after signal returns) - enable/disable.
1.3.6.1.4.1.4515.1.9.1.1.1.19TruthValueread-writecurrent
edfaMaxGain
OBJECT-TYPE
The EDFA max gain is determined by the result of the VER command. Legal values: gainUnknown(1) gain14dbm(2) - Booster/Inline, (-2)-14dBm output power, gain (-5)-22dB gain17dbm(3) - Booster/Inline, (-2)-17dBm output power, gain (-5)-22dB gain20dbm(4) - Booster/Inline, (-2)-20dBm output power, gain (-5)-22dB gain23dbm(5) - Booster/Inline, 5-23dBm output power, gain (-5)-22dB, 16 channels gain18dbmPreAmp8Ch(6) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChRed(7) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChBlue(8)- Preamp (-18)-0dBm output power, fixed gain 18dB gain23dbmGain10(9) - Booster/Inline, 23dBm output power with fixed gain of 10dB, 32 channels
1.3.6.1.4.1.4515.1.9.1.1.1.20INTEGERread-onlycurrent
edfaGainInFrom
OBJECT-TYPE
Lower input gain range of the edfa in units of 0.1 db.
1.3.6.1.4.1.4515.1.9.1.1.1.21INTEGERread-onlycurrent
edfaGainInTo
OBJECT-TYPE
Upper input gain range of the edfa in units of 0.1 db.
1.3.6.1.4.1.4515.1.9.1.1.1.22INTEGERread-onlycurrent
edfaGainOutFrom
OBJECT-TYPE
Lower output gain range of the edfa in units of 0.1 db.
1.3.6.1.4.1.4515.1.9.1.1.1.23INTEGERread-onlycurrent
edfaGainOutTo
OBJECT-TYPE
Upper output gain range of the edfa in units of 0.1 db.
1.3.6.1.4.1.4515.1.9.1.1.1.24INTEGERread-onlycurrent
edfaPowerInFrom
OBJECT-TYPE
Lower input power range of the edfa in units of 0.1 dbm.
1.3.6.1.4.1.4515.1.9.1.1.1.25INTEGERread-onlycurrent
edfaPowerInTo
OBJECT-TYPE
Upper input power range of the edfa in units of 0.1 dbm.
1.3.6.1.4.1.4515.1.9.1.1.1.26INTEGERread-onlycurrent
edfaPowerOutFrom
OBJECT-TYPE
Lower output power range of the edfa in units of 0.1 dbm.
1.3.6.1.4.1.4515.1.9.1.1.1.27INTEGERread-onlycurrent
edfaPowerOutTo
OBJECT-TYPE
Upper output power range of the edfa in units of 0.1 dbm.
1.3.6.1.4.1.4515.1.9.1.1.1.28INTEGERread-onlycurrent
edfaFromChannel
OBJECT-TYPE
The first channel number supported by the edfa; 0 to ignore.
1.3.6.1.4.1.4515.1.9.1.1.1.29INTEGERread-onlycurrent
edfaToChannel
OBJECT-TYPE
The last channel number supported by the edfa; 0 to ignore.
1.3.6.1.4.1.4515.1.9.1.1.1.30INTEGERread-onlycurrent
edfaOscChannel
OBJECT-TYPE
The wavelenght of the optical supervisory channel e.g. 1510, 1490.
1.3.6.1.4.1.4515.1.9.1.1.1.31INTEGERread-onlycurrent
edfaRedBlueType
OBJECT-TYPE
The type of the edaf.
1.3.6.1.4.1.4515.1.9.1.1.1.32INTEGER {red(1), blue(2), none(3)}read-onlycurrent
edfaRole
OBJECT-TYPE
The role of the edaf.
1.3.6.1.4.1.4515.1.9.1.1.1.33INTEGER {booster(1), boosterInline(2), preamp(3), inline(4), raman(5), other(6)}read-onlycurrent
edfaFreeDescription
OBJECT-TYPE
A free text with additional edfa information.
1.3.6.1.4.1.4515.1.9.1.1.1.34DisplayStringread-onlycurrent
edfaConfigSafetyThreshold
OBJECT-TYPE
The Eye Safety threshold level specified in dBm units. The value given in 0.1 dBm units. The range starts with -50.0 dBm.
1.3.6.1.4.1.4515.1.9.1.1.1.35INTEGERread-writecurrent
edfaTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.9.2
edfaTraps0
OBJECT-IDENTITY
1.3.6.1.4.1.4515.1.9.2.0

Notifications

NameOIDStatus
edfaStatusChange0
NOTIFICATION-TYPE
A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls. It is defined to support browsers that don't recognize RFC 2576.
1.3.6.1.4.1.4515.1.9.2.0.1current
edfaControlModeChange0
NOTIFICATION-TYPE
A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode. It is defined to support browsers that don't recognize RFC 2576.
1.3.6.1.4.1.4515.1.9.2.0.2current
edfaStatusChange
NOTIFICATION-TYPE
A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls.
1.3.6.1.4.1.4515.1.9.2.1current
edfaControlModeChange
NOTIFICATION-TYPE
A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode.
1.3.6.1.4.1.4515.1.9.2.2current