SL-DRY-CON-MIB
- Registered at
- 1.3.6.1.4.1.4515.1.7
- Last updated
- 2001-08-07 00:00
- Organization
- PacketLight Networks Ltd.
- Namespace
- packetlight
- Source file
SL-DRY-CON-MIB- Digest
sha256:6e3a51f0c65c1763d21a4ecdf39bbc4823f378ba9c06412c1d258815f242a013
Description
This MIB module describes the Dry Contacts.
Contact
Omri_Viner@PacketLight.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | InterfaceIndex, ifIndex |
| PerfHist-TC-MIB | PerfCurrentCount, PerfIntervalCount, PerfTotalCount |
| SL-NE-MIB | sitelight |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter64, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB PerfHist-TC-MIB SL-DRY-CON-MIB SL-NE-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| slDryConOut OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.7.1 | |||
| slDryConAlarmCutoff OBJECT-TYPE Setting this variable cause to Alarms Cutoff. | 1.3.6.1.4.1.4515.1.7.1.1 | INTEGER {dummy(1)} | read-write | current |
| slDryConOutTable OBJECT-TYPE The Dry Contact Out table configure the dry contact outputs. | 1.3.6.1.4.1.4515.1.7.1.2 | not-accessible | current | |
| slDryConOutEntry OBJECT-TYPE There is an entry for each Output Dry Contact | 1.3.6.1.4.1.4515.1.7.1.2.1 | not-accessible | current | |
| slDryConOutIndex OBJECT-TYPE The index of the output dry contact. | 1.3.6.1.4.1.4515.1.7.1.2.1.1 | INTEGER (1..4) | read-only | current |
| slDryConOutCommand OBJECT-TYPE Setting this object controls the output dry contact state: activate(1) - activate the output dry contact deactivate(2) - dectivate the output dry contact clear(3) - clears the output dry contact command The object value can also be read by the management. In this case the agent should return the current command to the management. The object value should not be kept in the NVRAM because it is used only for testing. The intial value should be clear(3). | 1.3.6.1.4.1.4515.1.7.1.2.1.2 | INTEGER {activate(1), deactivate(2), clear(3)} | read-write | current |
| slDryConOutActiveStatus OBJECT-TYPE The current status of the output dry contact: TRUE - means that it is currently active FLASE - means that it is not active | 1.3.6.1.4.1.4515.1.7.1.2.1.3 | TruthValue | read-only | current |
| slDryConIn OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.7.2 | |||
| slDryConLastChange OBJECT-TYPE The Sys Uptime at the last input change. | 1.3.6.1.4.1.4515.1.7.2.1 | INTEGER {dummy(1)} | read-only | current |
| slDryConInTable OBJECT-TYPE The Dry Contact In table describes the dry contacts inputs. | 1.3.6.1.4.1.4515.1.7.2.2 | not-accessible | current | |
| slDryConInEntry OBJECT-TYPE There is an entry for each Input Dry Contact | 1.3.6.1.4.1.4515.1.7.2.2.1 | not-accessible | current | |
| slDryConInIndex OBJECT-TYPE The index of the input dry contact. | 1.3.6.1.4.1.4515.1.7.2.2.1.1 | INTEGER (1..4) | read-only | current |
| slDryConInDescription OBJECT-TYPE A textual description of the input dry contact alarm. | 1.3.6.1.4.1.4515.1.7.2.2.1.2 | DisplayString (SIZE(0..40)) | read-write | current |
| slDryConInSeverity OBJECT-TYPE A severity of the input dry contact alarm. | 1.3.6.1.4.1.4515.1.7.2.2.1.3 | INTEGER {critical(1), major(2), minor(3), cleared(4), notification(5)} | read-write | current |
| slDryConInEnable OBJECT-TYPE Enable/Disable the input dry contact alarm report generation. | 1.3.6.1.4.1.4515.1.7.2.2.1.4 | INTEGER {enable(1), disable(2)} | read-write | current |
| slDryConInPolarity OBJECT-TYPE Determines the input dry contact alarm polarity. | 1.3.6.1.4.1.4515.1.7.2.2.1.5 | INTEGER {activeClose(1), activeOpen(2)} | read-write | current |
| slDryConInStatus OBJECT-TYPE Describe the current input dry contact alarm status. | 1.3.6.1.4.1.4515.1.7.2.2.1.6 | INTEGER {active(1), inactive(2)} | read-only | current |
| slDryConInAlmType OBJECT-TYPE Describe the current input dry contact alarm type. | 1.3.6.1.4.1.4515.1.7.2.2.1.7 | INTEGER {aircompr(1), aircond(2), airdryd(3), batdschrg(4), battery(5), clfan(6), cpmajor(7), cpminor(8), engine(9), engoprg(10), explgs(11), firdetr(12), fire(13), flood(14), fuse(15), gen(16), hiair(17), hihum(18), hitemp(19), hiwtr(20), intruder(21), lwbatvg(22), lwfuel(23), lwhum(24), lwpres(25), lwtemp(26), lwwtr(27), misc(28), opendr(29), pump(30), power(31), pwrX(32), rect(33), recthi(34), rectlo(35), smoke(36), toxicgas(37), ventn(38)} | read-write | current |
| slDryConTraps OBJECT-IDENTITY | 1.3.6.1.4.1.4515.1.7.3 |
Notifications
| Name | OID | Status |
|---|---|---|
| slDryConStatusChangeTrap NOTIFICATION-TYPE An slDryConStatusChangeTrap notification is sent when the the Status of an input dry contact is changed and the corresponding alarm is enabled. In order to shoten the Trap, the DisplayString that describes the alarm is not sent. To find out this string the NMS should use the index and get it from the table. | 1.3.6.1.4.1.4515.1.7.3.1 | current |