MIBs Depot

SIP-MIB

Registered at
1.3.6.1.2.1.10.31
1.3.6.1.2.1.36
Last updated
1994-03-31 18:18
Organization
IETF Interfaces Working Group
Namespace
standard
Source file
SIP-MIB
Digest
sha256:d8b4572903c5f852f7b869e0d36c1e5ece7ca43501c5932d80d1e3da76f649f7

Description

The MIB module to describe SMDS interfaces objects.

Contact

Tracy Brown Postal: Bell Communications Research 331 Newman Springs Road P.O. Box 7020 Red Bank, NJ 07701-7020 US Tel: +1 908 758-2107 Fax: +1 908 758-4177 E-mail: tacox@mail.bellcore.com Kaj Tesink Postal: Bell Communications Research 331 Newman Springs Road P.O. Box 7020 Red Bank, NJ 07701-7020 US Tel: +1 908 758 5254 Fax: +1 908 758 4177 E-mail: kaj@cc.bellcore.com.

Imports

FromSymbols
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, mib-2, transmission
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SIP-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
IfIndex
TEXTUAL-CONVENTION
The value of this object identifies the interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in RFC 1213, for the same interface.
current
SMDSAddress
TEXTUAL-CONVENTION
The 60-bit SMDS address, preceded by 4 bits with the following values: 1100 when representing an individual address 1110 when representing a group address.
current

Objects

NameOIDSyntaxAccessStatus
sip
OBJECT-IDENTITY
1.3.6.1.2.1.10.31
sipL3Table
OBJECT-TYPE
This table contains SIP L3 parameters and state variables, one entry per SIPL3 interface.
1.3.6.1.2.1.10.31.1not-accessiblecurrent
sipL3Entry
OBJECT-TYPE
This list contains SIP L3 parameters and state variables.
1.3.6.1.2.1.10.31.1.1not-accessiblecurrent
sipL3Index
OBJECT-TYPE
The value of this object identifies the SIP L3 interface for which this entry contains management information.
1.3.6.1.2.1.10.31.1.1.1IfIndexread-onlycurrent
sipL3ReceivedIndividualDAs
OBJECT-TYPE
The total number of individually addressed SIP Level 3 PDUs received from the remote system across the SNI. The total includes only unerrored L3PDUs.
1.3.6.1.2.1.10.31.1.1.2Counter32read-onlydeprecated
sipL3ReceivedGAs
OBJECT-TYPE
The total number of group addressed SIP Level 3 PDUs received from the remote system across the SNI. The total includes only unerrored L3PDUs.
1.3.6.1.2.1.10.31.1.1.3Counter32read-onlydeprecated
sipL3UnrecognizedIndividualDAs
OBJECT-TYPE
The number of SIP Level 3 PDUs received from the remote system with invalid or unknown individual destination addresses (Destination Address Screening violations are not included). See SMDS Subscription MIB module.
1.3.6.1.2.1.10.31.1.1.4Counter32read-onlydeprecated
sipL3UnrecognizedGAs
OBJECT-TYPE
The number of SIP Level 3 PDUs received from the remote system with invalid or unknown group addresses. (Destination Address Screening violations are not included). See SMDS Subscription MIB module.
1.3.6.1.2.1.10.31.1.1.5Counter32read-onlydeprecated
sipL3SentIndividualDAs
OBJECT-TYPE
The number of individually addressed SIP Level 3 PDUs that have been sent by this system across the SNI.
1.3.6.1.2.1.10.31.1.1.6Counter32read-onlydeprecated
sipL3SentGAs
OBJECT-TYPE
The number of group addressed SIP L3PDUs that have been sent by this system across the SNI.
1.3.6.1.2.1.10.31.1.1.7Counter32read-onlydeprecated
sipL3Errors
OBJECT-TYPE
The total number of SIP Level 3 PDUs received from the remote system that were discovered to have errors (including protocol processing and bit errors but excluding addressing-related errors) and were discarded. Includes both group addressed L3PDUs and L3PDUs containing an individual destination address.
1.3.6.1.2.1.10.31.1.1.8Counter32read-onlydeprecated
sipL3InvalidSMDSAddressTypes
OBJECT-TYPE
The number of SIP Level 3 PDUs received from the remote system that had the Source or Destination Address_Type subfields, (the four most significant bits of the 64 bit address field), not equal to the value 1100 or 1110. Also, an error is considered to have occurred if the Address_Type field for a Source Address, the four most significant bits of the 64 bits, is equal to 1110 (a group address).
1.3.6.1.2.1.10.31.1.1.9Counter32read-onlydeprecated
sipL3VersionSupport
OBJECT-TYPE
A value which indicates the version(s) of SIP that this interface supports. The value is a sum. This sum initially takes the value zero. For each version, V, that this interface supports, 2 raised to (V - 1) is added to the sum. For example, a port supporting versions 1 and 2 would have a value of (2^(1-1)+2^(2-1))=3. The sipL3VersionSupport is effectively a bit mask with Version 1 equal to the least significant bit (LSB).
1.3.6.1.2.1.10.31.1.1.10Integer32read-onlycurrent
sipL2Table
OBJECT-TYPE
This table contains SIP L2PDU parameters and state variables, one entry per SIP L2 interface.
1.3.6.1.2.1.10.31.2not-accessiblecurrent
sipL2Entry
OBJECT-TYPE
This list contains SIP L2 parameters and state variables.
1.3.6.1.2.1.10.31.2.1not-accessiblecurrent
sipL2Index
OBJECT-TYPE
The value of this object identifies the SIP interface for which this entry contains management information.
1.3.6.1.2.1.10.31.2.1.1IfIndexread-onlycurrent
sipL2ReceivedCounts
OBJECT-TYPE
The number of SIP Level 2 PDUs received from the remote system across the SNI. The total includes only unerrored L2PDUs.
1.3.6.1.2.1.10.31.2.1.2Counter32read-onlycurrent
sipL2SentCounts
OBJECT-TYPE
The number of SIP Level 2 PDUs that have been sent by this system across the SNI.
1.3.6.1.2.1.10.31.2.1.3Counter32read-onlycurrent
sipL2HcsOrCRCErrors
OBJECT-TYPE
The number of received SIP Level 2 PDUs that were discovered to have either a Header Check Sequence error or a Payload CRC violation.
1.3.6.1.2.1.10.31.2.1.4Counter32read-onlycurrent
sipL2PayloadLengthErrors
OBJECT-TYPE
The number of received SIP Level 2 PDUs that had Payload Length errors that fall in the following specifications: - SSM L2_PDU payload length field value less - than 28 octets or greater than 44 octets, - BOM or COM L2_PDU payload length field not - equal to 44 octets, - EOM L2_PDU payload length field value less - than 4 octets or greater than 44 octets.
1.3.6.1.2.1.10.31.2.1.5Counter32read-onlycurrent
sipL2SequenceNumberErrors
OBJECT-TYPE
The number of received SIP Level 2 PDUs that had a sequence number within the L2PDU not equal to the expected sequence number of the SMDS SS receive process.
1.3.6.1.2.1.10.31.2.1.6Counter32read-onlycurrent
sipL2MidCurrentlyActiveErrors
OBJECT-TYPE
The number of received SIP Level 2 PDUs that are BOMs for which an active receive process is already started.
1.3.6.1.2.1.10.31.2.1.7Counter32read-onlycurrent
sipL2BomOrSSMsMIDErrors
OBJECT-TYPE
The number of received SIP Level 2 PDUs that are SSMs with a MID not equal to zero or are BOMs with MIDs equal to zero.
1.3.6.1.2.1.10.31.2.1.8Counter32read-onlycurrent
sipL2EomsMIDErrors
OBJECT-TYPE
The number of received SIP Level 2 PDUs that are EOMs for which there is no active receive process for the MID (i.e., the receipt of an EOM which does not correspond to a BOM) OR the EOM has a MID equal to zero.
1.3.6.1.2.1.10.31.2.1.9Counter32read-onlycurrent
sipPLCP
OBJECT-IDENTITY
1.3.6.1.2.1.10.31.3
sipDS1PLCPTable
OBJECT-TYPE
This table contains SIP DS1 PLCP parameters and state variables, one entry per SIP port.
1.3.6.1.2.1.10.31.3.1not-accessiblecurrent
sipDS1PLCPEntry
OBJECT-TYPE
This list contains SIP DS1 PLCP parameters and state variables.
1.3.6.1.2.1.10.31.3.1.1not-accessiblecurrent
sipDS1PLCPIndex
OBJECT-TYPE
The value of this object identifies the interface for which this entry contains management information.
1.3.6.1.2.1.10.31.3.1.1.1IfIndexread-onlycurrent
sipDS1PLCPSEFSs
OBJECT-TYPE
A DS1 Severely Errored Framing Second (SEFS) is a count of one-second intervals containing one or more SEF events. A Severely Errored Framing (SEF) event is declared when an error in the A1 octet and an error in the A2 octet of a framing octet pair (i.e., errors in both framing octets), or two consecutive invalid and/or nonsequential Path Overhead Identifier octets are detected.
1.3.6.1.2.1.10.31.3.1.1.2Counter32read-onlycurrent
sipDS1PLCPAlarmState
OBJECT-TYPE
This variable indicates if there is an alarm present for the DS1 PLCP. The value receivedFarEndAlarm means that the DS1 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS1 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarm means that there are no alarms present. See TR-TSV-000773 for a description of alarm states.
1.3.6.1.2.1.10.31.3.1.1.3INTEGER {noAlarm(1), receivedFarEndAlarm(2), incomingLOF(3)}read-onlycurrent
sipDS1PLCPUASs
OBJECT-TYPE
The counter associated with the number of Unavailable Seconds, as defined by TR-TSV-000773, encountered by the PLCP.
1.3.6.1.2.1.10.31.3.1.1.4Counter32read-onlycurrent
sipDS3PLCPTable
OBJECT-TYPE
This table contains SIP DS3 PLCP parameters and state variables, one entry per SIP port.
1.3.6.1.2.1.10.31.3.2not-accessiblecurrent
sipDS3PLCPEntry
OBJECT-TYPE
This list contains SIP DS3 PLCP parameters and state variables.
1.3.6.1.2.1.10.31.3.2.1not-accessiblecurrent
sipDS3PLCPIndex
OBJECT-TYPE
The value of this object identifies the interface for which this entry contains management information.
1.3.6.1.2.1.10.31.3.2.1.1IfIndexread-onlycurrent
sipDS3PLCPSEFSs
OBJECT-TYPE
A DS3 Severely Errored Framing Second (SEFS) is a count of one-second intervals containing one or more SEF events. A Severely Errored Framing (SEF) event is declared when an error in the A1 octet and an error in the A2 octet of a framing octet pair (i.e., errors in both framing octets), or two consecutive invalid and/or nonsequential Path Overhead Identifier octets are detected.
1.3.6.1.2.1.10.31.3.2.1.2Counter32read-onlycurrent
sipDS3PLCPAlarmState
OBJECT-TYPE
This variable indicates if there is an alarm present for the DS3 PLCP. The value receivedFarEndAlarm means that the DS3 PLCP has received an incoming Yellow Signal, the value incomingLOF means that the DS3 PLCP has declared a loss of frame (LOF) failure condition, and the value noAlarm means that there are no alarms present. See TR-TSV-000773 for a description of alarm states.
1.3.6.1.2.1.10.31.3.2.1.3INTEGER {noAlarm(1), receivedFarEndAlarm(2), incomingLOF(3)}read-onlycurrent
sipDS3PLCPUASs
OBJECT-TYPE
The counter associated with the number of Unavailable Seconds, as defined by TR-TSV-000773, encountered by the PLCP.
1.3.6.1.2.1.10.31.3.2.1.4Counter32read-onlycurrent
smdsApplications
OBJECT-IDENTITY
1.3.6.1.2.1.10.31.4
ipOverSMDS
OBJECT-IDENTITY
1.3.6.1.2.1.10.31.4.1
ipOverSMDSTable
OBJECT-TYPE
The table of addressing information relevant to this entity's IP addresses.
1.3.6.1.2.1.10.31.4.1.1not-accessiblecurrent
ipOverSMDSEntry
OBJECT-TYPE
The addressing information for one of this entity's IP addresses.
1.3.6.1.2.1.10.31.4.1.1.1not-accessiblecurrent
ipOverSMDSIndex
OBJECT-TYPE
The value of this object identifies the interface for which this entry contains management information.
1.3.6.1.2.1.10.31.4.1.1.1.1IfIndexread-onlycurrent
ipOverSMDSAddress
OBJECT-TYPE
The IP address to which this entry's addressing information pertains.
1.3.6.1.2.1.10.31.4.1.1.1.2IpAddressread-onlycurrent
ipOverSMDSHA
OBJECT-TYPE
The SMDS Individual address of the IP station.
1.3.6.1.2.1.10.31.4.1.1.1.3SMDSAddressread-onlycurrent
ipOverSMDSLISGA
OBJECT-TYPE
The SMDS Group Address that has been configured to identify the SMDS Subscriber-Network Interfaces (SNIs) of all members of the Logical IP Subnetwork (LIS) connected to the network supporting SMDS.
1.3.6.1.2.1.10.31.4.1.1.1.4SMDSAddressread-onlycurrent
ipOverSMDSARPReq
OBJECT-TYPE
The SMDS address (individual or group) to which ARP Requests are to be sent.
1.3.6.1.2.1.10.31.4.1.1.1.5SMDSAddressread-onlycurrent
smdsCarrierSelection
OBJECT-IDENTITY
1.3.6.1.2.1.10.31.5
sipErrorLog
OBJECT-IDENTITY
1.3.6.1.2.1.10.31.6
sipL3PDUErrorTable
OBJECT-TYPE
A table that contains the latest occurrence of the following syntactical SIP L3PDU errors: - Destination Address Field Format Error, The following pertains to the 60 least significant bits of the 64 bit address field. The 60 bits contained in the address subfield can be used to represent addresses up to 15 decimal digits. Each decimal digit shall be encoded into four bits using Binary Coded Decimal (BCD), with the most significant digit occurring left-most. If not all 15 digits are required, then the remainder of this field shall be padded on the right with bits set to one. An error is considered to have occurred: a). if the first four bits of the address subfield are not BCD, OR b). if the first four bits of the address subfield are populated with the country code value 0001, AND the 40 bits which follow are not Binary Coded Decimal (BCD) encoded values of the 10 digit addresses, OR the remaining 16 least significant bits are not populated with 1's, OR c). if the address subfield is not correct according to another numbering plan which is dependent upon the carrier assigning the numbers and offering SMDS. - Source Address Field Format Error, The description of this parameter is the same as the description of the Destination Address Field Format Error. - Invalid BAsize Field Value, An error is considered to have occurred when the BAsize field of an SIP L3PDU contains a value less that 32, greater than 9220 octets without the CRC32 field present, greater than 9224 octets with the CRC32 field present, or not equal to a multiple of 4 octets, - Invalid Header Extension Length Field Value, An error is considered to have occurred when the Header Extension Length field value is not equal 3. - Invalid Header Extension - Element Length, An error is considered to have occurred when the Header Extension - Element Length is greater than 12. - Invalid Header Extension - Version Element Position, Length, or Value, An error is considered to have occurred when a Version element with Length=3, Type=0, and Value=1 does not appear first within the Header Extension, or an element Type=0 appears somewhere other than within the first three octets in the Header Extension. - Invalid Header Extension - Carrier Selection Element Position, Length, Value or Format, An error is considered to have occurred when a Carrier Selection element does not appear second within the Header Extension, if the Element Type does not equal 1, the Element Length does not equal 4, 6, or 8, the Element Value field is not four BCD encoded decimal digits used in specifying the Carrier Identification Code (CIC), or the identified CIC code is invalid. - Header Extension PAD Error An error is considered to have occurred when the Header Extension PAD is 9 octets in length, or if the Header Extension PAD is greater than zero octets in length and the Header Extension PAD does not follow all Header Extension elements or does not begin with at least one octet of all zeros. - BEtag Mismatch Error, An error is considered to have occurred when the Beginning-End Tags in the SIP L3PDU header and trailer are not equal. - BAsize Field not equal to Length Field Error, An error is considered to have occurred when the value of the BAsize Field does not equal the value of the Length Field. - Incorrect Length Error, and An error is considered to have occurred when the the Length field value is not equal to the portion of the SIP L3PDU which extends from the Destination Address field up to and including the CRC32 field (if present) or up to and including the PAD field (if the CRC32 field is not present). As an optional check, an error is considered to have occurred when the length of a partially received SIP L3PDU exceeds the BAsize value. - MRI Timeout Error. An error is considered to have occurred when the elapsed time between receipt of BOM and corresponding EOM exceeds the value of the MRI (Message Receive Interval) for a particular transport signal format. An entry is indexed by interface number and error type, and contains Source Address, Destination Address and a timestamp. All these errors are counted in the sipL3Errors counter. When sipL3PDUErrorTimeStamp is equal to zero, the SipL3PDUErrorEntry does not contain any valid information.
1.3.6.1.2.1.10.31.6.1not-accessiblecurrent
sipL3PDUErrorEntry
OBJECT-TYPE
An entry in the service disagreement table.
1.3.6.1.2.1.10.31.6.1.1not-accessiblecurrent
sipL3PDUErrorIndex
OBJECT-TYPE
The value of this object identifies the interface for which this entry contains management information.
1.3.6.1.2.1.10.31.6.1.1.1IfIndexread-onlycurrent
sipL3PDUErrorType
OBJECT-TYPE
The type of error.
1.3.6.1.2.1.10.31.6.1.1.2INTEGER {erroredDAFieldFormat(1), erroredSAFieldFormat(2), invalidBAsizeFieldValue(3), invalidHdrExtLength(4), invalidHdrExtElementLength(5), invalidHdrExtVersionElementPositionLenthOrValue(6), invalidHdrExtCarSelectElementPositionLenghtValueOrFormat(7), hePADError(8), beTagMismatch(9), baSizeFieldNotEqualToLengthField(10), incorrectLength(11), mriTimeout(12)}read-onlycurrent
sipL3PDUErrorSA
OBJECT-TYPE
A rejected SMDS source address.
1.3.6.1.2.1.10.31.6.1.1.3SMDSAddressread-onlycurrent
sipL3PDUErrorDA
OBJECT-TYPE
A rejected SMDS destination address.
1.3.6.1.2.1.10.31.6.1.1.4SMDSAddressread-onlycurrent
sipL3PDUErrorTimeStamp
OBJECT-TYPE
The timestamp for the service disagreement. The timestamp contains the value of sysUpTime at the latest occurrence of this type of service disagreement. See textual description under sipL3PDUErrorTable for boundary conditions.
1.3.6.1.2.1.10.31.6.1.1.5TimeStampread-onlycurrent
sipMIBObjects
OBJECT-IDENTITY
1.3.6.1.2.1.36.1
sipDxiTable
OBJECT-TYPE
The DXI table.
1.3.6.1.2.1.36.1.1not-accessiblecurrent
sipDxiEntry
OBJECT-TYPE
An entry in the DXI table.
1.3.6.1.2.1.36.1.1.1not-accessiblecurrent
sipDxiCrc
OBJECT-TYPE
The value of this object indicates the type of Frame Checksum used by DXI. Current choices include CCITT CRC16 or CRC32.
1.3.6.1.2.1.36.1.1.1.1INTEGER {crc16(1), crc32(2)}read-onlycurrent
sipDxiOutDiscards
OBJECT-TYPE
The number of outbound frames discarded because of congestion.
1.3.6.1.2.1.36.1.1.1.2Counter32read-onlycurrent
sipDxiInErrors
OBJECT-TYPE
The number of inbound frames discarded because of errors such as frame checksum (CRC) violations, non-integral number of octets, address and control field violations, and frame size errors.
1.3.6.1.2.1.36.1.1.1.3Counter32read-onlycurrent
sipDxiInAborts
OBJECT-TYPE
The number of inbound frames discarded because of an abort bit sequence (1111111) received before closing flag.
1.3.6.1.2.1.36.1.1.1.4Counter32read-onlycurrent
sipDxiInTestFrames
OBJECT-TYPE
The number of unerrored, inbound Test frames received (generally as part of Heart Beat Poll procedure).
1.3.6.1.2.1.36.1.1.1.5Counter32read-onlycurrent
sipDxiOutTestFrames
OBJECT-TYPE
The number of unerrored, outbound Test frames sent (generally as part of Heart Beat Poll procedure).
1.3.6.1.2.1.36.1.1.1.6Counter32read-onlycurrent
sipDxiHbpNoAcks
OBJECT-TYPE
The number of Heart Beat Poll (HBP) No Ack timeouts.
1.3.6.1.2.1.36.1.1.1.7Counter32read-onlycurrent
smdsConformance
OBJECT-IDENTITY
1.3.6.1.2.1.36.2
smdsGroups
OBJECT-IDENTITY
1.3.6.1.2.1.36.2.1
smdsCompliances
OBJECT-IDENTITY
1.3.6.1.2.1.36.2.2

Conformance

NameOIDStatus
sipLevel3Stuff
OBJECT-GROUP
A collection of objects providing information applicable to all SMDS interfaces.
1.3.6.1.2.1.36.2.1.1current
sipLevel2Stuff
OBJECT-GROUP
A collection of objects providing information specific to interfaces using the SIP Level 2.
1.3.6.1.2.1.36.2.1.2current
sipDS1PLCPStuff
OBJECT-GROUP
A collection of objects providing information specific to interfaces using the DS1 PLCP.
1.3.6.1.2.1.36.2.1.3current
sipDS3PLCPStuff
OBJECT-GROUP
A collection of objects providing information specific to interfaces using the DS3 PLCP.
1.3.6.1.2.1.36.2.1.4current
sipIPApplicationsStuff
OBJECT-GROUP
A collection of objects providing information for running IP over SMDS.
1.3.6.1.2.1.36.2.1.5current
sipDxiStuff
OBJECT-GROUP
A collection of objects providing information specific to interfaces using the DXI protocol.
1.3.6.1.2.1.36.2.1.6current
smdsCompliance
MODULE-COMPLIANCE
The compliance statement for SMDS interfaces.
1.3.6.1.2.1.36.2.2.1current