MIBs Depot

SIAE-SYNC-MIB

Registered at
1.3.6.1.4.1.3373.1103.28
Last updated
2014-04-02 00:00
Organization
SIAE MICROELETTRONICA spa
Revisions
2014-04-02 00:00, 2014-02-17 00:00, 2014-02-03 00:00, 2013-04-16 00:00
Namespace
siae
Source file
SIAE-SYNC-MIB
Digest
sha256:5a379e08532b0116d5880e71d2c0d365e969d23a1b30d47223a26a51f36404c0

Description

Timing Source Management.

Contact

SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: tbd@siaemic.com

Imports

FromSymbols
IF-MIBInterfaceIndexOrZero, ifIndex
SIAE-ALARM-MIBAlarmSeverityCode, AlarmStatus
SIAE-TREE-MIBsiaeMib
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SIAE-ALARM-MIB
SIAE-SYNC-MIB
SIAE-TREE-MIB
SIAE-USER-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
syncMibVersion
OBJECT-TYPE
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
1.3.6.1.4.1.3373.1103.28.1INTEGERread-onlycurrent
timingGeneratorTable
OBJECT-TYPE
Table with TimingGenerator records.
1.3.6.1.4.1.3373.1103.28.2not-accessiblecurrent
timingGeneratorRecord
OBJECT-TYPE
TimingGenerator record.
1.3.6.1.4.1.3373.1103.28.2.1not-accessiblecurrent
timingGeneratorId
OBJECT-TYPE
This object is used as Index of the Timing Generator Table.
1.3.6.1.4.1.3373.1103.28.2.1.1Integer32read-onlycurrent
timingGeneratorT4vsT0
OBJECT-TYPE
This object is used to set or reset the condition T4 equal T0.
1.3.6.1.4.1.3373.1103.28.2.1.2INTEGER {t4NotEqualT0(1), t4EqualT0(2)}read-createcurrent
timingGeneratorHoldOffTime
OBJECT-TYPE
HoldOff time in milliseconds (300..1800).
1.3.6.1.4.1.3373.1103.28.2.1.3INTEGER (300..1800)read-createcurrent
timingGeneratorWtrTime
OBJECT-TYPE
Wait Time to Restore in minutes (0..12).
1.3.6.1.4.1.3373.1103.28.2.1.4INTEGER (0..12)read-createcurrent
timingGeneratorSinkLosSet
OBJECT-TYPE
Wait time (seconds) before to set Los of reference signal.
1.3.6.1.4.1.3373.1103.28.2.1.5INTEGER (0..60)read-createcurrent
timingGeneratorSinkLosReset
OBJECT-TYPE
Wait time (seconds) before to reset Los of reference signal.
1.3.6.1.4.1.3373.1103.28.2.1.6INTEGER (0..60)read-createcurrent
timingGeneratorT0SquelchAlarm
OBJECT-TYPE
T0 squelch Alarm (Probable cause = xxx) with associated severity.
1.3.6.1.4.1.3373.1103.28.2.1.7AlarmStatusread-onlycurrent
timingGeneratorT4SquelchAlarm
OBJECT-TYPE
T4 squelch Alarm (Probable cause = xxx) with associated severity.
1.3.6.1.4.1.3373.1103.28.2.1.8AlarmStatusread-onlycurrent
timingGeneratorFreeRunningStatus
OBJECT-TYPE
Free running status (Probable cause = xxx) with associated severity.
1.3.6.1.4.1.3373.1103.28.2.1.9AlarmStatusread-onlycurrent
timingGeneratorHoldoverStatus
OBJECT-TYPE
Holdover status (Probable cause = xxx) with associated severity.
1.3.6.1.4.1.3373.1103.28.2.1.10AlarmStatusread-onlycurrent
timingGeneratorActiveStatus
OBJECT-TYPE
Active status (Probable cause = xxx) with associated severity.
1.3.6.1.4.1.3373.1103.28.2.1.11INTEGER {cleared(1), activeReportableStatus(2)}read-onlycurrent
timingGeneratorT0CurrentQuality
OBJECT-TYPE
Current quality on T0.
1.3.6.1.4.1.3373.1103.28.2.1.12INTEGER {qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-onlycurrent
timingGeneratorT4CurrentQuality
OBJECT-TYPE
Current quality on T4.
1.3.6.1.4.1.3373.1103.28.2.1.13INTEGER {qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-onlycurrent
timingGeneratorT4MinimumQuality
OBJECT-TYPE
If the Quality Level of the signal used to derive T4 falls below timingGeneratorT4MinimumQuality then the output will be squelched. The value ql-DNU inhibits T4 squelch due to this minimum Quality Level. This feature is enabled by timingGeneratorT4Squelch when timingGeneratorQualityEnable is on(2).
1.3.6.1.4.1.3373.1103.28.2.1.14INTEGER {qPRC(2), qSSUT(4), qSSUL(8), qSEC(11)}read-createcurrent
timingGeneratorT0PreferredSource
OBJECT-TYPE
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as preferential clock source of T0. If no preferential timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
1.3.6.1.4.1.3373.1103.28.2.1.15OBJECT IDENTIFIERread-createcurrent
timingGeneratorT4PreferredSource
OBJECT-TYPE
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as preferential clock source of T4. If no preferential timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
1.3.6.1.4.1.3373.1103.28.2.1.16OBJECT IDENTIFIERread-createcurrent
timingGeneratorRowStatus
OBJECT-TYPE
Status of this row of timingGeneratorTable.
1.3.6.1.4.1.3373.1103.28.2.1.17RowStatusread-createcurrent
timingGeneratorMaintTable
OBJECT-TYPE
Table with TimingGenerator records.
1.3.6.1.4.1.3373.1103.28.3not-accessiblecurrent
timingGeneratorMaintRecord
OBJECT-TYPE
TimingGenerator record.
1.3.6.1.4.1.3373.1103.28.3.1not-accessiblecurrent
timingGeneratorT4Squelch
OBJECT-TYPE
This object is used to enable/disable T4 squelch.
1.3.6.1.4.1.3373.1103.28.3.1.1INTEGER {disable(1), enable(2)}read-writecurrent
timingGeneratorStatusControl
OBJECT-TYPE
Clock generator operating mode control. This item is linked to a manual operation (ManOpRecord) instance.
1.3.6.1.4.1.3373.1103.28.3.1.2INTEGER {freerunning(1), holdover(2), locked(3)}read-writecurrent
timingGeneratorT0ForcedSource
OBJECT-TYPE
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as forced clock source of T0. If no forced timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
1.3.6.1.4.1.3373.1103.28.3.1.3OBJECT IDENTIFIERread-writecurrent
timingGeneratorT4ForcedSource
OBJECT-TYPE
Object identifier of the leaf timingSinkGenId of the timingSink instance selected as forced clock source of T4. If no forced timing sink is selected, the value should be set to the OBJECT IDENTIFIER { 0 0 }.
1.3.6.1.4.1.3373.1103.28.3.1.4OBJECT IDENTIFIERread-writecurrent
timingGeneratorWtrClearSource
OBJECT-TYPE
Object identifier of the leaf timingSinkGenId of the timingSink instance selected to clear WTR time. On read, this object return alvays an OBJECT IDENTIFIER {0 0}.
1.3.6.1.4.1.3373.1103.28.3.1.5OBJECT IDENTIFIERread-writecurrent
timingSinkTable
OBJECT-TYPE
Table with TimingSink records.
1.3.6.1.4.1.3373.1103.28.4not-accessiblecurrent
timingSinkRecord
OBJECT-TYPE
TimingSink record.
1.3.6.1.4.1.3373.1103.28.4.1not-accessiblecurrent
timingSinkGenId
OBJECT-TYPE
This object is used as Index of the timingGeneratorTable and defines in union with timingSinkType and timingSinkId the reference signal.
1.3.6.1.4.1.3373.1103.28.4.1.1Integer32read-onlycurrent
timingSinkId
OBJECT-TYPE
This object is used as Index of the timingSinkTable and defines in union with timingSinkType and timingSinkGenId the reference signal.
1.3.6.1.4.1.3373.1103.28.4.1.2Integer32read-onlycurrent
timingSinkType
OBJECT-TYPE
This object is used as Index of the timingSinkTable and defines if the reference signal is used to generate T0 or T4 system clock.
1.3.6.1.4.1.3373.1103.28.4.1.3INTEGER {t0(1), t4(2)}read-onlycurrent
timingSinkIfIndex
OBJECT-TYPE
The ifIndex value the agent selected for this timingSink interface.
1.3.6.1.4.1.3373.1103.28.4.1.4InterfaceIndexOrZeroread-onlycurrent
timingSinkSelector
OBJECT-TYPE
This object is used to select one of the possible clock source connected to this timingSink. Valid values are listed in timingSinkSelectorTable: only values of timingSinkSelectorId related to this instance of timinkSinkRecord are accepted. Only the values corresponding to the index timingSinkSelectorId of timinkSinkSelectorTable related to this instance of timinkSinkRecord will be accepted.
1.3.6.1.4.1.3373.1103.28.4.1.5Integer32read-createcurrent
timingSinkPriority
OBJECT-TYPE
This object is used to set the priority of the reference signal (p1 is the highest priority).
1.3.6.1.4.1.3373.1103.28.4.1.6INTEGER {p1(1), p2(2), p3(3), p4(4), p5(5), p6(6), p7(7), p8(8), p9(9), p10(10), p11(11), p12(12), p13(13), p14(14), p15(15), disable(16)}read-createcurrent
timingSinkLabel
OBJECT-TYPE
ASCII string used to describe the reference signal when a trap is sent.
1.3.6.1.4.1.3373.1103.28.4.1.7DisplayString (SIZE(0..31))read-onlycurrent
timingSinkLosAlarm
OBJECT-TYPE
Loss of reference signal (Probable cause = xxx) alarm with associated severity.
1.3.6.1.4.1.3373.1103.28.4.1.8AlarmStatusread-onlycurrent
timingSinkDriftAlarm
OBJECT-TYPE
Drift of reference signal (Probable cause = xxx) alarm with associated severity.
1.3.6.1.4.1.3373.1103.28.4.1.9AlarmStatusread-onlycurrent
timingSinkActiveStatus
OBJECT-TYPE
Active status (Probable cause = xxx) status for the reference signal.
1.3.6.1.4.1.3373.1103.28.4.1.10INTEGER {cleared(1), activeReportableStatus(2)}read-onlycurrent
timingSinkCurrentQuality
OBJECT-TYPE
Current quality on sink instance.
1.3.6.1.4.1.3373.1103.28.4.1.11INTEGER {qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-onlycurrent
timingSinkOverwriteTxQuality
OBJECT-TYPE
Forcing of Tx quality parameter.
1.3.6.1.4.1.3373.1103.28.4.1.12INTEGER {noOverwrite(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-createcurrent
timingSinkOverwriteRxQuality
OBJECT-TYPE
Forcing of Rx quality parameter.
1.3.6.1.4.1.3373.1103.28.4.1.13INTEGER {noOverwrite(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-createcurrent
timingSinkSentQuality
OBJECT-TYPE
Quality level written in the S1 byte of the outgoing STM-n.
1.3.6.1.4.1.3373.1103.28.4.1.14INTEGER {qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-onlycurrent
timingSinkE1Sabit
OBJECT-TYPE
Specifies the San synchronization status bit used to indicate the clock quality level. Meaningful when the Sink source is an E1
1.3.6.1.4.1.3373.1103.28.4.1.15INTEGER (4..8)read-createcurrent
timingSinkEthPortRole
OBJECT-TYPE
This item configures how to handle the role of a 1000BASE-T port when it is used as a source of timing: choosing 'static', the role is set according ethLanPhyTable settings, choosing 'dynamic', the role is set consistently with the timing direction over the 1000baseT link chosen by SSM protocol.
1.3.6.1.4.1.3373.1103.28.4.1.16INTEGER {static(1), dynamic(2)}read-createdeprecated
timingSinkRowStatus
OBJECT-TYPE
Status of this row of timingSinkTable
1.3.6.1.4.1.3373.1103.28.4.1.17RowStatusread-createcurrent
timingGeneratorManualSwitch
OBJECT-TYPE
timingGeneratorId of the forced timingGenerator instance. If no preferred timing generator is selected, the value should be set to 0.
1.3.6.1.4.1.3373.1103.28.5Integer32read-writecurrent
timingGeneratorForcedSwitch
OBJECT-TYPE
timingGeneratorId of the forced timingGenerator instance. If no forced timing generator is selected, the value should be set to 0.
1.3.6.1.4.1.3373.1103.28.6Integer32read-writecurrent
timingGeneratorT0SquelchAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the TimingGeneratorT0SquelchAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.7AlarmSeverityCoderead-writecurrent
timingGeneratorT4SquelchAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the timingGeneratorT4SquelchAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.8AlarmSeverityCoderead-writecurrent
timingGeneratorFreeRunningStatusSeverityCode
OBJECT-TYPE
Defines the severity associated to the timingGeneratorFreeRunningStatus and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.9AlarmSeverityCoderead-writecurrent
timingGeneratorHoldoverStatusSeverityCode
OBJECT-TYPE
Defines the severity associated to the timingGeneratorHoldoverStatus and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.10AlarmSeverityCoderead-writecurrent
timingGeneratorActiveStatusSeverityCode
OBJECT-TYPE
Defines the severity associated to the timingGeneratorActiveStatus and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.11INTEGER {disable(1), statusTrapEnable(2)}read-writecurrent
timingGeneratorQualityEnable
OBJECT-TYPE
Quality policy enable
1.3.6.1.4.1.3373.1103.28.12INTEGER {off(1), on(2)}read-writecurrent
timingSinkLosAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the TimingSinkLosAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.13AlarmSeverityCoderead-writecurrent
timingSinkDriftAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the TimingSinkDriftAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.14AlarmSeverityCoderead-writecurrent
timingSinkActiveStatusSeverityCode
OBJECT-TYPE
Defines the severity associated to the timingSinkActiveStatus and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.28.15INTEGER {disable(1), statusTrapEnable(2)}read-writecurrent
timingSinkSelectorTable
OBJECT-TYPE
Table with TimingSinkSelector records.
1.3.6.1.4.1.3373.1103.28.16not-accessiblecurrent
timingSinkSelectorRecord
OBJECT-TYPE
TimingSinkSelector entry. Several instances of this entry can be create for each instance of timingSinkTable. Each entry represents a possible source selected by a multiplexer outside the SETS for a specific timingSink. Only the values corresponding to the index timingSinkSelectorId can be set to timingSinkSelector.
1.3.6.1.4.1.3373.1103.28.16.1not-accessiblecurrent
timingSinkSelectorId
OBJECT-TYPE
This object is used as Index of the timingSinkSelectorTable and defines in union with timingSinkGenId, timingSinkType and timingSinkId the selected source by a multiplexer outside the SETS.
1.3.6.1.4.1.3373.1103.28.16.1.1Integer32read-onlycurrent
timingSinkSelectorLabel
OBJECT-TYPE
ASCII string used to describe the selectable timing source.
1.3.6.1.4.1.3373.1103.28.16.1.2DisplayString (SIZE(0..31))read-onlycurrent
esmcTable
OBJECT-TYPE
Table with TimingSinkSelector records.
1.3.6.1.4.1.3373.1103.28.17not-accessiblecurrent
esmcRecord
OBJECT-TYPE
esmcTable entry. Every entries describes an ESMC channel of a TE interface.
1.3.6.1.4.1.3373.1103.28.17.1not-accessiblecurrent
esmcSsmEnable
OBJECT-TYPE
This object enables SSM messaging on this ifIndex.
1.3.6.1.4.1.3373.1103.28.17.1.1INTEGER {disable(1), enable(2)}read-createcurrent
esmcQlRx
OBJECT-TYPE
This object show quality received on ESMC-PDU this interface.
1.3.6.1.4.1.3373.1103.28.17.1.2INTEGER {qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-onlycurrent
esmcQlTx
OBJECT-TYPE
This object show quality transmitted in ESMC-PDU on this interface.
1.3.6.1.4.1.3373.1103.28.17.1.3INTEGER {qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15)}read-onlycurrent
esmcPktsRx
OBJECT-TYPE
This object contains the total number of received ESMC-PDU packets on this interface.
1.3.6.1.4.1.3373.1103.28.17.1.4Counter32read-onlycurrent
esmcPktsTx
OBJECT-TYPE
This object contains the total number of transmitted ESMC-PDU packets on this interface.
1.3.6.1.4.1.3373.1103.28.17.1.5Counter32read-onlycurrent
esmcPktsRxDropped
OBJECT-TYPE
This object contains the total number of dropped ESMC-PDU packets on this interface.
1.3.6.1.4.1.3373.1103.28.17.1.6Counter32read-onlycurrent
esmcPktsRxErrored
OBJECT-TYPE
This object contains the total number of dropped ESMC-PDU packets whose processing(decoding) resulted into error.
1.3.6.1.4.1.3373.1103.28.17.1.7Counter32read-onlycurrent
esmc1000BaseTRole
OBJECT-TYPE
This object allows to input the clock generator role of a 1000BaseT interface. This objects is applicable when the quality management is disabled (timingGeneratorQualityEnable set to off(1)) and to all interfaces not connected to any timingSink when the quality management is enabled.
1.3.6.1.4.1.3373.1103.28.17.1.8INTEGER {slave(1), master(2), auto(3)}read-createcurrent
esmcRowStatus
OBJECT-TYPE
Status of this row of esmcTable.
1.3.6.1.4.1.3373.1103.28.17.1.9RowStatusread-createcurrent