SIAE-SENSOR-TEMP-MIB
- Registered at
- 1.3.6.1.4.1.3373.1103.77
- Last updated
- 2016-05-03 00:00
- Organization
- SIAE MICROELETTRONICA spa
- Revisions
- 2016-05-03 00:00, 2014-03-31 00:00
- Namespace
- siae
- Source file
SIAE-SENSOR-TEMP-MIB- Digest
sha256:281b715c08d6aa444186587f5d84ffaa721c5292b1924d8ee42d8b039ec500cb
Description
Management information for equipment heat.
Contact
SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: tbd@siaemic.com
Imports
| From | Symbols |
|---|---|
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus |
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SIAE-ALARM-MIB SIAE-SENSOR-TEMP-MIB SIAE-TREE-MIB SIAE-USER-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| sensorTempMibVersion OBJECT-TYPE Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. | 1.3.6.1.4.1.3373.1103.77.1 | INTEGER | read-only | current |
| sensorTempTable OBJECT-TYPE Table with sensorTemp device entries | 1.3.6.1.4.1.3373.1103.77.2 | not-accessible | current | |
| sensorTempEntry OBJECT-TYPE Temperature Sensor entry | 1.3.6.1.4.1.3373.1103.77.2.1 | not-accessible | current | |
| sensorTempIndex OBJECT-TYPE Temperature Sensor index. | 1.3.6.1.4.1.3373.1103.77.2.1.1 | Integer32 | read-only | current |
| sensorTempValue OBJECT-TYPE Value of the temperature (in Celsius). | 1.3.6.1.4.1.3373.1103.77.2.1.2 | Integer32 | read-only | current |
| sensorTempThreshold1 OBJECT-TYPE This object can not be modified. It reports the temperature threshold 1. When sensorTempValue exceeds this value sensorTempStatus1 becomes Active. When threshold has been exceed status returns stand-by only when sensorTempValue goes under sensorTempHysteresis1. | 1.3.6.1.4.1.3373.1103.77.2.1.3 | Integer32 | read-only | current |
| sensorTempThreshold2 OBJECT-TYPE This object can not be modified. It reports the temperature threshold 2. When sensorTempValue exceeds this value sensorTempStatus2 becomes Active. When threshold has been exceed status returns stand-by only when sensorTempValue goes under sensorTempHysteresis2. | 1.3.6.1.4.1.3373.1103.77.2.1.4 | Integer32 | read-only | current |
| sensorTempHysteresis1 OBJECT-TYPE This object can not be modified. It reports the temperature hysteresis 1. When sensorTempStatus1 is Active it represents the value under which returns cleared. | 1.3.6.1.4.1.3373.1103.77.2.1.5 | Integer32 | read-only | current |
| sensorTempHysteresis2 OBJECT-TYPE This object can not be modified. It reports the temperature hysteresis 2. When sensorTempStatus1 is Active it represents the value under which returns cleared. | 1.3.6.1.4.1.3373.1103.77.2.1.6 | Integer32 | read-only | current |
| sensorTempStatus1 OBJECT-TYPE This object is used to manage temperature related to sensorTempThreshold1. Values mean: cleared: sensorTempValue is lower than threshold1 active: sensorTempValue is greater than threshold1 hysteresis: sensorTempValue is between threshold1 and hysteresis1 but previuosly greater than thresold1. | 1.3.6.1.4.1.3373.1103.77.2.1.7 | INTEGER {cleared(1), alarmed(2), hysteresis(3)} | read-only | current |
| sensorTempStatus2 OBJECT-TYPE This object is used to manage temperature related to sensorTempThreshold2. Values mean: cleared: sensorTempValue is lower than threshold2 active: sensorTempValue is greater than threshold2 hysteresis: sensorTempValue is between threshold2 and hysteresis2 but previuosly greater than thresold2. | 1.3.6.1.4.1.3373.1103.77.2.1.8 | INTEGER {cleared(1), alarmed(2), hysteresis(3)} | read-only | current |
| sensorTempLabel OBJECT-TYPE A textual string containing information on sensorTemp sensor. | 1.3.6.1.4.1.3373.1103.77.2.1.9 | DisplayString (SIZE(0..32)) | read-only | current |
| sensorTempAlarmThreshold1 OBJECT-TYPE This object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus1 alarmed. | 1.3.6.1.4.1.3373.1103.77.3 | AlarmStatus | read-only | current |
| sensorTempAlarmThreshold2 OBJECT-TYPE This object is used to notiy alarm if at least one entry in the sensorTemp table has got sensorTempStatus2 alarmed. | 1.3.6.1.4.1.3373.1103.77.4 | AlarmStatus | read-only | current |
| sensorTempAlarmThreshold1Severity OBJECT-TYPE This object is used to change severity of sensorTempAlarmThreshold1. | 1.3.6.1.4.1.3373.1103.77.5 | AlarmSeverityCode | read-write | current |
| sensorTempAlarmThreshold2Severity OBJECT-TYPE This object is used to change severity of sensorTempAlarmThreshold2. | 1.3.6.1.4.1.3373.1103.77.6 | AlarmSeverityCode | read-write | current |
| sensorTempMonitorTable OBJECT-TYPE Table with sensorTempMonitor entries | 1.3.6.1.4.1.3373.1103.77.7 | not-accessible | current | |
| sensorTempMonitorEntry OBJECT-TYPE Temperature Sensor Monitor entry | 1.3.6.1.4.1.3373.1103.77.7.1 | not-accessible | current | |
| sensorTempMonitorAdminStatus OBJECT-TYPE The desired state of the temperatuure monitor. When a managed system initializes, all the temperature monitors start with sensorTempMonitorAdminStatus in the down(2) state, it's a default state also. As a result of either explicit management action or per configuration information retained by the managed system, sensorTempMonitorAdminStatus is then changed to the up(1) state (or remains in the down(2) state). | 1.3.6.1.4.1.3373.1103.77.7.1.1 | INTEGER {up(1), down(2)} | read-write | current |
| sensorTempMonitorOperStatus OBJECT-TYPE The current state of the temperatuure monitor. Usually this object report the same value of sensorTempMonitorAdminStatus. When there is some problem related to the temperature sensor, this object shown the down(2) value even if sensorTempMonitorAdminStatus is set to up(1). | 1.3.6.1.4.1.3373.1103.77.7.1.2 | INTEGER {up(1), down(2)} | read-only | current |
| sensorTempMonitorMinTemp OBJECT-TYPE The minimum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius. | 1.3.6.1.4.1.3373.1103.77.7.1.3 | Integer32 | read-only | current |
| sensorTempMonitorMaxTemp OBJECT-TYPE The maximum value of the temperature measured in the last actual 900 seconds. The value is expressed in degrees Celsius. | 1.3.6.1.4.1.3373.1103.77.7.1.4 | Integer32 | read-only | current |
| sensorTempMonitorAverageTemp OBJECT-TYPE The average value of the temperature measured in the last actual 900 seconds. The value is expressed in tenth of degrees Celsius. | 1.3.6.1.4.1.3373.1103.77.7.1.5 | Integer32 | read-only | current |
| sensorTempMonitorSystemControl OBJECT-TYPE The administrative system control status requested by management for the TEMP-MONITOR feature. The value 'start'(1) indicates that TEMP-MONITOR should be supported in the device on all temperature sensors that have this capability (Those shown in sensorTempMonitorTable). The value shutdown(2) indicates that TEMP-MONITOR should be shutdown in the device on all temperature sensors. | 1.3.6.1.4.1.3373.1103.77.8 | INTEGER {start(1), shutdown(2)} | read-write | current |