SIAE-RADIO-SYSTEM-MIB
- Registered at
- 1.3.6.1.4.1.3373.1103.80
- Last updated
- 2016-07-14 00:00
- Organization
- SIAE MICROELETTRONICA spa
- Revisions
- 2016-07-14 00:00, 2016-02-29 00:00, 2015-09-15 00:00, 2015-06-18 00:00, 2015-03-23 00:00, 2014-11-05 00:00, 2014-09-16 00:00, 2014-04-01 00:00
- Namespace
- siae
- Source file
SIAE-RADIO-SYSTEM-MIB- Digest
sha256:6122532b0d3de2594182fa3127e90fc78762fadb50d07ff1cbd7732dc47cf75d
Description
Radio System MIB.
Contact
SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: help@siaemic.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | InterfaceIndexOrZero |
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus, alarmTrap |
| SIAE-EQUIP-MIB | equipIpSnmpAgentAddress |
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, StorageType, TEXTUAL-CONVENTION |
Imported by
1 module(s) in this corpus import this one.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB SIAE-ALARM-MIB SIAE-EQUIP-MIB SIAE-EQUIPTYPE-MIB SIAE-RADIO-SYSTEM-MIB SIAE-TREE-MIB SIAE-USER-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| BitsPerSymbol TEXTUAL-CONVENTION his TC describes a data type which identifies a RF channel spacing. | current | |||
| ChannelSpacing TEXTUAL-CONVENTION This TC describes a data type which identifies a RF channel spacing. | current | |||
| ConfigMismatchReason TEXTUAL-CONVENTION This data type is used to specify the cause of Config Mismatch Alarm, that is the mismatch between the radio link capability and the current local and remote configuration. - securityMismatch(0) Copyright violation - frequencyFailMismatch(1) Configured frequency is out of Filter-Bandwidth - frequencyAlertMismatch(2) Configured frequency across Filter-Bandwidth - ptxMismatch(3) Tx power configured incongruent with RF Tx power limits - channelSpacingAndModulationMismatch(4) Bandwidth and/or modulation configured is invalid (RF doesn't support it) - remoteConfigurationMismatch(5) Incongruence between the couple of Terminal Radio Unit (TRU) in the link: - Frequency Incongruent (Freq) - Reference Bandwidth and Modulation incongruent - Acm-Tx map in congruent with remote Acm-Rx map - acmMismatch(6) Obsolete (no longer used) - profileSetMismatch(7) The selected profile set is not supported by the TRU | current | |||
| ModulationMap TEXTUAL-CONVENTION This data type is used as the syntax of the radioBranchModulationMap and radioBranchRefModulationMap objects. | current | |||
| RadioCapability TEXTUAL-CONVENTION This data type is used as the syntax of the radioBranchKeyFeatures objects. | current | |||
| Stm1IndexOrZero TEXTUAL-CONVENTION This textual convention permits the additional value of zero to an stm1Index in stm1Table. The value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where stm-1 was unknown, or when none or all stm-1s need to be referenced. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| radioSystemMibVersion OBJECT-TYPE Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. | 1.3.6.1.4.1.3373.1103.80.1 | INTEGER | read-only | current |
| radioTable OBJECT-TYPE A list of radio interface entries. This table is useful to show the manager all the available radio interfaces on the equipment. Moreover it is a reference for Performance Monitoring (PWR and G828). | 1.3.6.1.4.1.3373.1103.80.2 | not-accessible | current | |
| radioEntry OBJECT-TYPE An entry containing management information applicable to a particular radio interface. | 1.3.6.1.4.1.3373.1103.80.2.1 | not-accessible | current | |
| radioIndex OBJECT-TYPE A unique value, greater than zero, for each radio interface. It is recommended that values are assigned contiguously starting from 1. | 1.3.6.1.4.1.3373.1103.80.2.1.1 | Integer32 | read-only | current |
| radioLabel OBJECT-TYPE A textual string containing information about the radio interface. This string should include the name of the manufacturer, the product name and the version of the interface hardware/software. | 1.3.6.1.4.1.3373.1103.80.2.1.2 | DisplayString (SIZE(0..32)) | read-only | current |
| radioType OBJECT-TYPE The type of interface. | 1.3.6.1.4.1.3373.1103.80.2.1.3 | INTEGER {other(1), analogRadio(2), digitalRadio(3), xpicRadio(4)} | read-only | current |
| radioIfIndex OBJECT-TYPE This object defines a greater than zero value to identify an interface in ifTable or a zero value if ifTable is not supported. | 1.3.6.1.4.1.3373.1103.80.2.1.4 | InterfaceIndexOrZero | read-only | current |
| radioStorageType OBJECT-TYPE The storage type of this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row. | 1.3.6.1.4.1.3373.1103.80.2.1.5 | StorageType | read-only | current |
| xpicTable OBJECT-TYPE A list of xpic radio interface entries. If a manager wants to make an xpic link, it should only add a particular xpic radio interface to an xpic link. | 1.3.6.1.4.1.3373.1103.80.3 | not-accessible | current | |
| xpicEntry OBJECT-TYPE An entry containing management information applicable to a particular xpic radio interface. | 1.3.6.1.4.1.3373.1103.80.3.1 | not-accessible | current | |
| xpicIndex OBJECT-TYPE A unique value, greater than zero, for each xpic radio interface. It is recommended that values are assigned contiguously starting from 1. | 1.3.6.1.4.1.3373.1103.80.3.1.1 | Integer32 | read-only | current |
| xpicRadioIdx OBJECT-TYPE Index of xpic radio interface, corresponding to an available xpic radio interface in radioTable. | 1.3.6.1.4.1.3373.1103.80.3.1.2 | Integer32 | read-create | current |
| xpicRowstatus OBJECT-TYPE Status of this conceptual row in xpicTable. | 1.3.6.1.4.1.3373.1103.80.3.1.3 | RowStatus | read-create | current |
| xpicChTable OBJECT-TYPE A list of xpic channel entries. This table maps each xpic radio in respective xpic radio interface. | 1.3.6.1.4.1.3373.1103.80.4 | not-accessible | current | |
| xpicChEntry OBJECT-TYPE An entry containing management information applicable to a particular xpic channel. It defines radio interface and polarization for a given xpic channel. | 1.3.6.1.4.1.3373.1103.80.4.1 | not-accessible | current | |
| xpicChPolIndex OBJECT-TYPE This object identifies the xpic radio polarization. | 1.3.6.1.4.1.3373.1103.80.4.1.1 | Integer32 (1..2) | read-only | current |
| xpicChRadioIdx OBJECT-TYPE Xpic radio interface, corresponding to a radio interface in radioTable, used to make up the given xpic radio interface. | 1.3.6.1.4.1.3373.1103.80.4.1.2 | Integer32 | read-create | current |
| xpicChRowstatus OBJECT-TYPE Status of this conceptual row in xpicChTable. | 1.3.6.1.4.1.3373.1103.80.4.1.3 | RowStatus | read-create | current |
| linkAvailableIndex OBJECT-TYPE Shows an index which is available for creation of a new link in the system. It shows the smallest available index. Any attempt to create a link with a different index results in a failure. | 1.3.6.1.4.1.3373.1103.80.5 | Integer32 | read-only | current |
| linkTable OBJECT-TYPE A list of link entries. | 1.3.6.1.4.1.3373.1103.80.6 | not-accessible | current | |
| linkEntry OBJECT-TYPE An entry containing management information applicable to a particular link. | 1.3.6.1.4.1.3373.1103.80.6.1 | not-accessible | current | |
| linkIndex OBJECT-TYPE A unique value, greater than zero, for each link. Manager must use the first available index, suggested by linkAvailableIndex. | 1.3.6.1.4.1.3373.1103.80.6.1.1 | Integer32 | read-only | current |
| linkType OBJECT-TYPE This object identifies link type. Supported link types are: single link, 1+1 Hot Standby, 1+1 Frequency Diversity, 2+0 XPIC, 2+2 XPIC Hot Standby, 2+2 XPIC Frequency Diversity and N+1. | 1.3.6.1.4.1.3373.1103.80.6.1.2 | INTEGER {radio1p0(1), radio1p1HS(2), radio1p1FD(3), radio2p0Xpic(4), radio2p2XpicHS(5), radio2p2XpicFD(6), radioNp1(7)} | read-create | current |
| linkLabel OBJECT-TYPE A textual string containing information about the link. This string should give more details about link specific parameters. | 1.3.6.1.4.1.3373.1103.80.6.1.3 | DisplayString (SIZE(0..32)) | read-create | current |
| linkIfIndex OBJECT-TYPE This object defines a greater than zero value to identify a link in ifTable or a zero value if ifTable is not supported. | 1.3.6.1.4.1.3373.1103.80.6.1.4 | InterfaceIndexOrZero | read-only | current |
| linkRowstatus OBJECT-TYPE Status of this row of linkTable. This object is used to manage the creation and deletion of conceptual rows in linkTable. To create a row in this table, a manager should set rowstatus to createAndWait(5) and choose a link type. Respective entries in linkSettingsTable, linkStatusTable and tdmSettingsTable will be created by agent.In case of protection links proper entries in linkProtectionTable will be also created. Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of rowstatus is notReady(3). When there is sufficient information to (attempt to) make the conceptual row available for use by the managed device, then the rowstatus column turns into notInService(2); manager must set rowstatus to active(1) to make the conceptual row active. The contents of linkSettingsTable and radioSettingsTable can be changed only if this object is notInService(2). | 1.3.6.1.4.1.3373.1103.80.6.1.5 | RowStatus | read-create | current |
| linkChTable OBJECT-TYPE A list of link channel entries. | 1.3.6.1.4.1.3373.1103.80.7 | not-accessible | current | |
| linkChEntry OBJECT-TYPE An entry containing management information applicable to a particular link channel. | 1.3.6.1.4.1.3373.1103.80.7.1 | not-accessible | current | |
| linkChIndex OBJECT-TYPE Link Channel Index. | 1.3.6.1.4.1.3373.1103.80.7.1.1 | Integer32 | read-only | current |
| linkChRadioIdx OBJECT-TYPE Radio channel index that corresponds to an available radio interface in radioTable. | 1.3.6.1.4.1.3373.1103.80.7.1.2 | Integer32 | read-create | current |
| linkChRadioSettingsIdx OBJECT-TYPE Radio Settings Index. This object is a foreign key for a corresponding radioSettingsTable entry, which is automatically created by agent. | 1.3.6.1.4.1.3373.1103.80.7.1.3 | Integer32 | read-create | current |
| linkChRowstatus OBJECT-TYPE Status of this row of linkChTable. This object is used to manage the creation and deletion of conceptual rows in linkChTable. To create a row in this table, a manager should set rowstatus to createAndWait(5). Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of rowstatus is notReady(3). When there is sufficient information to (attempt to) make the conceptual row available for use by the managed device, then the rowstatus column turns into notInService(2); manager must set rowstatus to active(1) to make the conceptual row active. The content of radioSettingsTable can be changed only if this object is notInService(2). | 1.3.6.1.4.1.3373.1103.80.7.1.4 | RowStatus | read-create | current |
| linkSettingsTable OBJECT-TYPE Table with link settings entries. This table contains all parameters of a radio frequency link. The content of this table can be changed by a manager if linkRowStatus is notInService(2). | 1.3.6.1.4.1.3373.1103.80.8 | not-accessible | current | |
| linkSettingsEntry OBJECT-TYPE Radio link entry | 1.3.6.1.4.1.3373.1103.80.8.1 | not-accessible | current | |
| linkBandwidthAndModulation OBJECT-TYPE Link Modulation and Bandwidth (channel spacing). The value of this object value is computed by: 65536*modulation+bandwidth where bandwidth selection is: 0 = 3.5Mhz 1 = 7MHz 2 = 14MHz 3 = 28MHz 4 = 56MHz 5 = 10MHz 6 = 20MHz 7 = 30MHz 8 = 40MHz 9 = 50MHz 10 = 112Mhz 11 = 250Mhz 12 = 500Mhz 13 = 750Mhz 14 = 1Ghz 15 = 60MHz 16 = 80MHz and modulation is in bit-per-symbol: 1 = BPSK 2 = 4QAM 3 = 8PSK 4 = 16QAM 5 = 32QAM 6 = 64QAM 7 = 128QAM 8 = 256QAM 9 = 512QAM 10 = 1024QAM 11 = 2048QAM. 12 = 4096QAM. Examples: 250Mhz-4QAM (131083), 500Mhz-4QAM (131084), 250Mhz-16QAM (262155), 500Mhz-64QAM (393228). Note: 0 bit-per-symbol is not possible, so value 0 is used for BandwidthAndModulation unassigned. | 1.3.6.1.4.1.3373.1103.80.8.1.1 | Integer32 | read-create | current |
| linkAcmEngineEnable OBJECT-TYPE This object is used to enable/disable the ACM engine | 1.3.6.1.4.1.3373.1103.80.8.1.2 | INTEGER {disable(1), enable(2)} | read-create | current |
| linkTxUpperProfile OBJECT-TYPE The object (and linkTxLowerProfile object) is used to restrict the TX profile range when ACM is enabled. | 1.3.6.1.4.1.3373.1103.80.8.1.3 | INTEGER | read-create | current |
| linkTxLowerProfile OBJECT-TYPE The object (and linkTxUpperProfile object) is used to restrict the TX profile range when ACM is enabled. | 1.3.6.1.4.1.3373.1103.80.8.1.4 | INTEGER | read-create | current |
| linkId OBJECT-TYPE Link Identification (value 0..255) | 1.3.6.1.4.1.3373.1103.80.8.1.5 | INTEGER (0..255) | read-create | current |
| linkTxPwrThresh OBJECT-TYPE Threshold (value +3 , +15 dB) relative to nominal value of the TX power below wich the related alarm is set. | 1.3.6.1.4.1.3373.1103.80.8.1.6 | INTEGER (3..15) | read-create | current |
| linkRxPwrThresh OBJECT-TYPE Threshold (value -40 , -99 dBm) for RX power below wich the related alarm is set. | 1.3.6.1.4.1.3373.1103.80.8.1.7 | INTEGER (-99..-40) | read-create | current |
| linkSynchSetupProtocolEnable OBJECT-TYPE Synchronization Setup Protocol (SSP) control | 1.3.6.1.4.1.3373.1103.80.8.1.8 | INTEGER {disable(1), enable(2)} | read-create | current |
| linkProfilesSetSelection OBJECT-TYPE Selection of the working profile set between high gain (max robustness) profile set and high throughput (max capacity) profile set. The set of profiles high gain features a greater robustness against to the set of profiles high throughput. For radio systems that do not have more sets of profiles, this object becomes read only and its reading shows the only one set of profiles supported. | 1.3.6.1.4.1.3373.1103.80.8.1.9 | INTEGER {highThroughput(1), highGain(2)} | read-create | current |
| linkXpicControlProcedure OBJECT-TYPE Set by manager to enable\disable XPIC alarm control procedure. Only for XPIC configurations. | 1.3.6.1.4.1.3373.1103.80.8.1.10 | INTEGER {disable(1), enable(2)} | read-create | current |
| radioSettingsTable OBJECT-TYPE Table with radio settings entries. This table contains all parameters of a radio terminal. The content of this table can be changed only linkRowStatus is notInService(2) | 1.3.6.1.4.1.3373.1103.80.9 | not-accessible | current | |
| radioSettingsEntry OBJECT-TYPE Radio terminal entry | 1.3.6.1.4.1.3373.1103.80.9.1 | not-accessible | current | |
| radioSettingsIndex OBJECT-TYPE Radio settings index. | 1.3.6.1.4.1.3373.1103.80.9.1.1 | Integer32 | read-only | current |
| radioSettingsRowStatus OBJECT-TYPE Status of this row. | 1.3.6.1.4.1.3373.1103.80.9.1.2 | RowStatus | read-create | current |
| radioSettingsLabel OBJECT-TYPE A textual string containing information about the radio interface. | 1.3.6.1.4.1.3373.1103.80.9.1.3 | DisplayString (SIZE(0..32)) | read-only | current |
| radioTxFrequency OBJECT-TYPE Transmitted frequency in KHz. Null value means invalid frequency. | 1.3.6.1.4.1.3373.1103.80.9.1.4 | INTEGER | read-create | current |
| radioDuplexFrequency OBJECT-TYPE Value of duplex frequency in KHz. -2 means not set. | 1.3.6.1.4.1.3373.1103.80.9.1.5 | INTEGER | read-create | current |
| radioTxAttenuation OBJECT-TYPE Transmitter attenuation relative to nominal power (dBm). | 1.3.6.1.4.1.3373.1103.80.9.1.6 | INTEGER | read-create | current |
| radioAtpcManual OBJECT-TYPE Enables/disables Atpc Manual operation. | 1.3.6.1.4.1.3373.1103.80.9.1.7 | INTEGER {disable(1), enable(2)} | read-create | current |
| radioAtpcPwrHigh OBJECT-TYPE ATPC Control - Local Rx Power High (dBm range -30 to -80) -. | 1.3.6.1.4.1.3373.1103.80.9.1.8 | Integer32 | read-create | current |
| radioAtpcPwrLow OBJECT-TYPE ATPC Control - Local Rx Power Low (dBm range -30 to -80) -. | 1.3.6.1.4.1.3373.1103.80.9.1.9 | Integer32 | read-create | current |
| radioAtpcRange OBJECT-TYPE Defines the range of the ATPC regulation (expressed in dB) with respect to the current value of maximum Tx output, that is intended as the upper limit of the range. A null value means no limit: the lower limit of the range is equal to minimum Ptx. | 1.3.6.1.4.1.3373.1103.80.9.1.10 | Integer32 | read-create | current |
| radioFreqTableSelection OBJECT-TYPE RadioFrequencyTable key (channel spacing & modulation) selection. | 1.3.6.1.4.1.3373.1103.80.9.1.11 | ChannelSpacing | read-create | current |
| tdmSettingsTable OBJECT-TYPE Table with tdm settings entries. | 1.3.6.1.4.1.3373.1103.80.10 | not-accessible | current | |
| tdmSettingsEntry OBJECT-TYPE An entry containing tdm parameters for a particular link. | 1.3.6.1.4.1.3373.1103.80.10.1 | not-accessible | current | |
| tdmPolIndex OBJECT-TYPE Polarization index. | 1.3.6.1.4.1.3373.1103.80.10.1.1 | Integer32 | read-only | current |
| tdmE1Channel OBJECT-TYPE Number of E1 channels. This object is used to define the capacity of E1 tributaries assigned to a given radio link. The capacity is changed in steps of E1 (2Mbit/s). | 1.3.6.1.4.1.3373.1103.80.10.1.2 | Integer32 | read-write | current |
| tdmE1Framer OBJECT-TYPE This object is used to attach the framer to a given E1. | 1.3.6.1.4.1.3373.1103.80.10.1.3 | INTEGER {disable(1), enable(2)} | read-write | current |
| radioCapabilitiesTable OBJECT-TYPE Table with RadioCapabilities entries: there is an entry for each radioTable rows. | 1.3.6.1.4.1.3373.1103.80.11 | not-accessible | current | |
| radioCapabilitiesEntry OBJECT-TYPE RadioCapabilities entry. | 1.3.6.1.4.1.3373.1103.80.11.1 | not-accessible | current | |
| radioCapabilitiesCapability OBJECT-TYPE Bit map to describe the radio features. | 1.3.6.1.4.1.3373.1103.80.11.1.1 | RadioCapability | read-only | current |
| radioCapabilitiesTxMinFrequency OBJECT-TYPE Minimum of available channel frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.11.1.2 | Integer32 | read-only | current |
| radioCapabilitiesTxMaxFrequency OBJECT-TYPE Maximum of available channel frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.11.1.3 | Integer32 | read-only | current |
| radioCapabilitiesStepFrequency OBJECT-TYPE Minimum frequency step in KHz. | 1.3.6.1.4.1.3373.1103.80.11.1.4 | Integer32 | read-only | current |
| radioCapabilitiesMinPtxNominalValue OBJECT-TYPE Minimum nominal Ptx in dBm. | 1.3.6.1.4.1.3373.1103.80.11.1.5 | Integer32 | read-only | current |
| radioCapabilitiesMaxPtxNominalValue OBJECT-TYPE Maximum nominal Ptx in dBm. | 1.3.6.1.4.1.3373.1103.80.11.1.6 | Integer32 | read-only | current |
| radioCapabilitiesExtendedMinPwr OBJECT-TYPE Minimum extended Ptx power for fade margin. | 1.3.6.1.4.1.3373.1103.80.11.1.7 | Integer32 | read-only | current |
| radioStatusTable OBJECT-TYPE Table with RadioStatus records: one record for 1+0 configuration and two record for 1+1 configuration. | 1.3.6.1.4.1.3373.1103.80.12 | not-accessible | current | |
| radioStatusEntry OBJECT-TYPE RadioStatus record. | 1.3.6.1.4.1.3373.1103.80.12.1 | not-accessible | current | |
| radioCurrentDuplexFrequency OBJECT-TYPE Spacing between transmitted and received frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.12.1.1 | Integer32 | read-only | current |
| radioTxChannelSpacing OBJECT-TYPE Half of transmitted signal channel spacing in KHz. | 1.3.6.1.4.1.3373.1103.80.12.1.2 | Integer32 | read-only | current |
| radioPrx OBJECT-TYPE Received power level (dBm). | 1.3.6.1.4.1.3373.1103.80.12.1.3 | Integer32 | read-only | current |
| radioPtx OBJECT-TYPE Transmitted power level (dBm). | 1.3.6.1.4.1.3373.1103.80.12.1.4 | Integer32 | read-only | current |
| radioNormalizedMse OBJECT-TYPE Normalized MSE (Mean Squared Error) is an indicator of the Signal to Noise (S/N) ratio. It's in 0.1 dB steps | 1.3.6.1.4.1.3373.1103.80.12.1.5 | Integer32 | read-only | current |
| radioRxActiveStatus OBJECT-TYPE Receiver Active status with associated Severity In 1+1 Hot Standby radio system, only one RX is active. RXs are active in other configurations of the radio system. | 1.3.6.1.4.1.3373.1103.80.12.1.6 | INTEGER {cleared(1), active(2)} | read-only | current |
| radioTxActiveStatus OBJECT-TYPE Transmitter Active status with associated Severity. In 1+1 Hot Standby radio system, only one TX is active. TXs are active in other configurations of the radio system. | 1.3.6.1.4.1.3373.1103.80.12.1.7 | INTEGER {cleared(1), active(2)} | read-only | current |
| radioCableOpenAlarm OBJECT-TYPE Cable connnecting ODU is open: alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.8 | AlarmStatus | read-only | current |
| radioCableShortAlarm OBJECT-TYPE Cable connnecting ODU is in short-circuit: alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.9 | AlarmStatus | read-only | current |
| radioInvalidFrequencyAlarm OBJECT-TYPE Invalid frequency alarm with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.10 | AlarmStatus | read-only | current |
| radioBaseBandRxAlarm OBJECT-TYPE Base Band Rx alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.11 | AlarmStatus | read-only | current |
| radioModulatorFailAlarm OBJECT-TYPE Modulator Fail Alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.12 | AlarmStatus | read-only | current |
| radioDemodulatorFailAlarm OBJECT-TYPE Demodulator Fail Alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.13 | AlarmStatus | read-only | current |
| radioRxPowerLowAlarm OBJECT-TYPE Receiver power low alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.14 | AlarmStatus | read-only | current |
| radioTxPowerLowAlarm OBJECT-TYPE Transmitter power low alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.15 | AlarmStatus | read-only | current |
| radioRemDemodulatorFailAlarm OBJECT-TYPE Remote Demodulator Fail Alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.16 | AlarmStatus | read-only | current |
| radioVcoFailAlarm OBJECT-TYPE RT VCO fail alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.17 | AlarmStatus | read-only | current |
| radioRxIFAgcAlarm OBJECT-TYPE RT Rx IF AGC fail alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.18 | AlarmStatus | read-only | current |
| radioTxIFAgcAlarm OBJECT-TYPE RT Tx IF AGC fail alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.19 | AlarmStatus | read-only | current |
| radioIduOduCommunicationAlarm OBJECT-TYPE Communication from IDU towards ODU is down | 1.3.6.1.4.1.3373.1103.80.12.1.20 | AlarmStatus | read-only | current |
| radioOduIduCommunicationAlarm OBJECT-TYPE Communication from ODU towards IDU is down | 1.3.6.1.4.1.3373.1103.80.12.1.21 | AlarmStatus | read-only | current |
| radioLocalOduAlarmSynthesis OBJECT-TYPE Local ODU alarm synthesis with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.22 | AlarmStatus | read-only | current |
| radioRemoteOduAlarmSynthesis OBJECT-TYPE Local ODU alarm synthesis alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.23 | AlarmStatus | read-only | current |
| radioConfigMismatchAlarm OBJECT-TYPE Config Mismatch alarm status with associated severity and related map. | 1.3.6.1.4.1.3373.1103.80.12.1.24 | AlarmStatus | read-only | current |
| radioConfigAlarmReason OBJECT-TYPE Bit map to describe the Config Mismatch Alarm | 1.3.6.1.4.1.3373.1103.80.12.1.25 | ConfigMismatchReason | read-only | current |
| radioRxQualityLowAlarm OBJECT-TYPE High BER Alarm status with associated severity. | 1.3.6.1.4.1.3373.1103.80.12.1.26 | AlarmStatus | read-only | current |
| radioRxQualityWarningAlarm OBJECT-TYPE The RX signal is close to cause errors on payload. | 1.3.6.1.4.1.3373.1103.80.12.1.27 | AlarmStatus | read-only | current |
| radioXpd OBJECT-TYPE Cross-Polarization Discrimination, in tenths of dB, is the difference between the received signal power of the co-polarized main beam, and it componemt received on the cross-polarized signal. This object shows an extimated value of the XPD performed by the cross-polarization interference canceller (XPIC). This means that the measure is reliable if: - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), or radio2p2XpicFD(6)) - Alarm radioDemodulatorFailAlarm is cleared. - XPD is not too high, since without cross-polar interference the canceller is not able to works well. Basically, in this condition, the extimated XPD is greater than the real one. | 1.3.6.1.4.1.3373.1103.80.12.1.28 | Integer32 | read-only | current |
| radioMaintTable OBJECT-TYPE Table with Command for maintenance of radio branch. Objects in this table is not persistent. An Instance of this table is created on creation of radioBranchEntry | 1.3.6.1.4.1.3373.1103.80.13 | not-accessible | current | |
| radioMaintEntry OBJECT-TYPE Radio branch Maintenance record. | 1.3.6.1.4.1.3373.1103.80.13.1 | not-accessible | current | |
| radioTxStatus OBJECT-TYPE Transmitter status control. The value transmitterOff(1) is related to a manual operation. The value permanentOff(3) is persistent across restart. | 1.3.6.1.4.1.3373.1103.80.13.1.1 | INTEGER {transmitterOff(1), transmitterOn(2), permanentOff(3)} | read-write | current |
| radioCarrierOnly OBJECT-TYPE Carrier only transmission control. | 1.3.6.1.4.1.3373.1103.80.13.1.2 | INTEGER {carrierOnlyOff(1), carrierOnlyOn(2)} | read-write | current |
| radioLoop OBJECT-TYPE Enables/disables the Radio Branch loops. | 1.3.6.1.4.1.3373.1103.80.13.1.3 | INTEGER {loopOff(1), rfLoop(2), iqLoop(3), baseBandLoop(4), rfLoopAtFixedMod(6), baseBandLoopEthSquelch(7), rfLoopAtFixedModEthSquelch(8), iqloopEthSquelch(9)} | read-write | current |
| radioRFLoopTestResult OBJECT-TYPE Radio branch RT loop test result. | 1.3.6.1.4.1.3373.1103.80.13.1.4 | INTEGER {testNone(0), testRunning(1), testNotPossible(2), testPassed(3), testFail(4), testInterrupted(5)} | read-only | current |
| radioRFLoopTestPercTime OBJECT-TYPE Radio branch RT loop test time percentage | 1.3.6.1.4.1.3373.1103.80.13.1.5 | INTEGER (0..100) | read-only | current |
| radioRtPsuOff OBJECT-TYPE It switches on/off the Rt power supply | 1.3.6.1.4.1.3373.1103.80.13.1.6 | INTEGER {rtPsuOff(1), rtPsuOn(2)} | read-write | current |
| radioLom OBJECT-TYPE It is used to enable the IP packet forwarding towards Radio. | 1.3.6.1.4.1.3373.1103.80.13.1.7 | INTEGER {disable(1), enable(2)} | read-write | current |
| radioXpic OBJECT-TYPE Enable of the cross polarization interference cancellation of this radio. The value disable is tied to a manual operation (ManOpRecord). This object is applicable only if thiis radio belongs to a 2+0 XPIC or 2+2 XPIC link. | 1.3.6.1.4.1.3373.1103.80.13.1.8 | INTEGER {disable(1), enable(2)} | read-write | current |
| radioFrequencyTable OBJECT-TYPE Availables channels for selected channel spacing and modulation (see leaf radioFreqTableSelection). | 1.3.6.1.4.1.3373.1103.80.14 | not-accessible | current | |
| radioFreqTabEntry OBJECT-TYPE RadioFreqTab record. | 1.3.6.1.4.1.3373.1103.80.14.1 | not-accessible | current | |
| radioFreqChannelId OBJECT-TYPE Index of the table | 1.3.6.1.4.1.3373.1103.80.14.1.1 | Integer32 | read-only | current |
| radioFreqChannelNum OBJECT-TYPE Available channel number. | 1.3.6.1.4.1.3373.1103.80.14.1.2 | Integer32 | read-only | current |
| radioFreqValue OBJECT-TYPE Frequency related to radioFreqChannelNum. | 1.3.6.1.4.1.3373.1103.80.14.1.3 | Integer32 | read-only | current |
| radioDuplexFrequencyTable OBJECT-TYPE Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. | 1.3.6.1.4.1.3373.1103.80.15 | not-accessible | current | |
| radioDuplexFreqEntry OBJECT-TYPE Duplex Frequency entry. There is an entry for each available duplex frequency. | 1.3.6.1.4.1.3373.1103.80.15.1 | not-accessible | current | |
| radioDuplexFreqId OBJECT-TYPE Index of the table. | 1.3.6.1.4.1.3373.1103.80.15.1.1 | Integer32 | read-only | current |
| radioDuplexFreqValue OBJECT-TYPE Duplex frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.15.1.2 | Integer32 | read-only | current |
| radioModulationTable OBJECT-TYPE List of modulations related to channel spacing. | 1.3.6.1.4.1.3373.1103.80.16 | not-accessible | current | |
| radioModulationEntry OBJECT-TYPE radioModulation record. | 1.3.6.1.4.1.3373.1103.80.16.1 | not-accessible | current | |
| radioChannelSpacing OBJECT-TYPE This object identifies the channel spacing. | 1.3.6.1.4.1.3373.1103.80.16.1.1 | ChannelSpacing | read-only | current |
| radioModulationMap OBJECT-TYPE List of modulations in the radioChanSpacing | 1.3.6.1.4.1.3373.1103.80.16.1.2 | ModulationMap | read-only | current |
| radioRefModulationMap OBJECT-TYPE List of modulations that can be selected as reference in the radioChanSpacingId | 1.3.6.1.4.1.3373.1103.80.16.1.3 | ModulationMap | read-only | current |
| linkStatusTable OBJECT-TYPE Table with LinkStatusEntry. | 1.3.6.1.4.1.3373.1103.80.17 | not-accessible | current | |
| linkStatusEntry OBJECT-TYPE Link status entry | 1.3.6.1.4.1.3373.1103.80.17.1 | not-accessible | current | |
| linkPolIndex OBJECT-TYPE This object identifies the radio polarization. In XPIC radio link identifies one of the polarizations. | 1.3.6.1.4.1.3373.1103.80.17.1.1 | INTEGER (1..2) | read-only | current |
| linkAcmRxProfile OBJECT-TYPE This object reports the ACM profile number in use in the radio Rx. It is the linkAcmProfileId of linkAcmTable. Label is linkAcmProfileLabel from linkAcmTable | 1.3.6.1.4.1.3373.1103.80.17.1.2 | Integer32 | read-only | current |
| linkAcmTxProfile OBJECT-TYPE This object reports the ACM profile number in use in the radio Tx. It is the linkAcmProfileId of linkAcmTable. Label is linkAcmProfileLabel from linkAcmTable | 1.3.6.1.4.1.3373.1103.80.17.1.3 | Integer32 | read-only | current |
| linkAcmRxProfileLabel OBJECT-TYPE ASCII string used to describe current acm rx profile | 1.3.6.1.4.1.3373.1103.80.17.1.4 | DisplayString (SIZE(0..32)) | read-only | current |
| linkAcmTxProfileLabel OBJECT-TYPE ASCII string used to describe current acm tx profile | 1.3.6.1.4.1.3373.1103.80.17.1.5 | DisplayString (SIZE(0..32)) | read-only | current |
| linkAcmRxModulation OBJECT-TYPE This object is the type of modulation of the Rx profile in use. | 1.3.6.1.4.1.3373.1103.80.17.1.6 | BitsPerSymbol | read-only | current |
| linkAcmTxModulation OBJECT-TYPE This object is the type of modulation of the Tx profile in use. | 1.3.6.1.4.1.3373.1103.80.17.1.7 | BitsPerSymbol | read-only | current |
| linkAcmRxCode OBJECT-TYPE This object is the type of codificator of the Rx profile in use. | 1.3.6.1.4.1.3373.1103.80.17.1.8 | INTEGER {unknown(0), normal(1), strong(2)} | read-only | current |
| linkAcmTxCode OBJECT-TYPE This object is the type of codificator of the Tx profile in use. | 1.3.6.1.4.1.3373.1103.80.17.1.9 | INTEGER {unknown(0), normal(1), strong(2)} | read-only | current |
| linkTxETHCapacity OBJECT-TYPE This object reports (in Kbits/sec) the transmitted payload capacity used by the Ethernet | 1.3.6.1.4.1.3373.1103.80.17.1.10 | Integer32 | read-only | current |
| linkRxETHCapacity OBJECT-TYPE This object reports (in Kbits/sec) the received payload capacity used by the Ethernet | 1.3.6.1.4.1.3373.1103.80.17.1.11 | Integer32 | read-only | current |
| linkTxTDMCapacity OBJECT-TYPE This object reports the capacity in kbit/sec reserved to TDM tributaries in tx ACM profile. | 1.3.6.1.4.1.3373.1103.80.17.1.12 | Integer32 | read-only | current |
| linkRxTDMCapacity OBJECT-TYPE This object reports the capacity in kbit/sec reserved to TDM tributaries in rx ACM profile. | 1.3.6.1.4.1.3373.1103.80.17.1.13 | Integer32 | read-only | current |
| linkRescueModulation OBJECT-TYPE This object is the modulation used when the remote terminal is unreachable, ie traffic on radio link is down. | 1.3.6.1.4.1.3373.1103.80.17.1.14 | BitsPerSymbol | read-only | current |
| linkReducedCapacityAlarm OBJECT-TYPE The equipment works in reduced capacity | 1.3.6.1.4.1.3373.1103.80.17.1.15 | AlarmStatus | read-only | current |
| linkLinkTelemetryFailAlarm OBJECT-TYPE Fail of link telemetry communication channel with associated Severity | 1.3.6.1.4.1.3373.1103.80.17.1.16 | AlarmStatus | read-only | current |
| linkIdMismatchAlarm OBJECT-TYPE Link Identification Alarm with associated Severity | 1.3.6.1.4.1.3373.1103.80.17.1.17 | AlarmStatus | read-only | current |
| linkRadioEocAlarm OBJECT-TYPE Fail of Radio Eoc link communication channel with associated Severity | 1.3.6.1.4.1.3373.1103.80.17.1.18 | AlarmStatus | read-only | current |
| linkSetupMismatchAlarm OBJECT-TYPE The local setup doesn't match the setup of remote terminal | 1.3.6.1.4.1.3373.1103.80.17.1.19 | AlarmStatus | read-only | current |
| linkRescueSetupAlarm OBJECT-TYPE The equipment is using the setup relative to the rescue modulation | 1.3.6.1.4.1.3373.1103.80.17.1.20 | AlarmStatus | read-only | current |
| linkXpicProcedureBlockAlarm OBJECT-TYPE Only for XPIC equipment configurations. Equipment Controller XPIC procedure Alarm control with associated Severity | 1.3.6.1.4.1.3373.1103.80.17.1.21 | AlarmStatus | read-only | current |
| linkXpicRemTxOffAlarm OBJECT-TYPE Only for XPIC equipment configurations. Remote TX OFF command with associated Severity | 1.3.6.1.4.1.3373.1103.80.17.1.22 | AlarmStatus | read-only | current |
| linkRemoteIduAlarmSynthesis OBJECT-TYPE Synthesis of the remote IDU alarms | 1.3.6.1.4.1.3373.1103.80.17.1.23 | AlarmStatus | read-only | current |
| linkNotMatchingRadiosAlarm OBJECT-TYPE Radios of the link does not have matched parameters. | 1.3.6.1.4.1.3373.1103.80.17.1.24 | AlarmStatus | read-only | current |
| linkConfigurationInProgress OBJECT-TYPE The link is being configured and the table linkSettingsTable is not available for modifying parameters. | 1.3.6.1.4.1.3373.1103.80.17.1.25 | INTEGER {cleared(1), active(2)} | read-only | current |
| linkXpd OBJECT-TYPE Cross-Polarization Discrimination, in tenths of dB, is the difference between the received signal power of the co-polarized main beam, and it componemt received on the cross-polarized signal. This object shows an extimated value of the XPD performed by the cross-polarization interference canceller (XPIC). This means that the measure is reliable if: - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), or radio2p2XpicFD(6)) - Alarm radioDemodulatorFailAlarm is cleared. - XPD is not too high, since without cross-polar interference the canceller is not able to works well. Basically, in this condition, the extimated XPD is greater than the real one. | 1.3.6.1.4.1.3373.1103.80.17.1.26 | Integer32 | read-only | deprecated |
| linkTfcTable OBJECT-TYPE Transmitter Fail Check feature. In 1+1 HS configuration, the radio terminal that doesn't receive signals on both receivers, requests the remote transmitter switch. This table was deprecated and replaced by linkTfcV2Table. It is a view of the rows of the linkTfcV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers. | 1.3.6.1.4.1.3373.1103.80.18 | not-accessible | deprecated | |
| linkTfcEntry OBJECT-TYPE Radio link TFC entry. | 1.3.6.1.4.1.3373.1103.80.18.1 | not-accessible | deprecated | |
| linkTfcAction OBJECT-TYPE reset: to clear the forced switch generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.18.1.1 | INTEGER {notActive(0), reset(1)} | read-create | deprecated |
| linkTfcControl OBJECT-TYPE It enables the Tx switch from remote equipment (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.18.1.2 | INTEGER {disable(1), enable(2)} | read-create | deprecated |
| linkTfcWatchWindow OBJECT-TYPE Watch Window (in seconds) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.18.1.3 | INTEGER (1..300) | read-create | deprecated |
| linkTfcAlarmThreshold OBJECT-TYPE Alarm Threshold (number of seconds with both remote RX in fail) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.18.1.4 | INTEGER (1..60) | read-create | deprecated |
| linkTfcAlarm OBJECT-TYPE Transmission switch alarm generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.18.1.5 | AlarmStatus | read-only | deprecated |
| linkTfcRowStatus OBJECT-TYPE Status of this conceptual row in linkTfcTable. | 1.3.6.1.4.1.3373.1103.80.18.1.6 | RowStatus | read-create | deprecated |
| linkMaintTable OBJECT-TYPE Table with commands for maintenance of radio link. Objects in this table is not persistent. An Instance of this table is created on creation of linkStatusEntry | 1.3.6.1.4.1.3373.1103.80.19 | not-accessible | current | |
| linkMaintEntry OBJECT-TYPE Radio link maintenance entry. | 1.3.6.1.4.1.3373.1103.80.19.1 | not-accessible | current | |
| linkBerStart OBJECT-TYPE Stop, Start (resetting errors and counters) the pattern. This item is linked to a manual operation (ManOpRecord) instance. | 1.3.6.1.4.1.3373.1103.80.19.1.1 | INTEGER {restart(1), stop(2)} | read-write | current |
| linkBaseBandLom OBJECT-TYPE It is used to enable the IP packet forwarding towards modems. This item is linked to a manual operation (ManOpRecord) instance. | 1.3.6.1.4.1.3373.1103.80.19.1.2 | INTEGER {disable(1), enable(2)} | read-write | current |
| linkFadeMarginMeasure OBJECT-TYPE Set by manager to start/stop fade margin measure. This item is linked to a manual operation (ManOpRecord) instance. This object is deprecated and replaced by fadeMarginMeasure. | 1.3.6.1.4.1.3373.1103.80.19.1.3 | INTEGER {disable(1), enable(2)} | read-write | deprecated |
| linkXpicControlProcedureReset OBJECT-TYPE Set by manager to reset the XPIC control procedure after a blocking action. | 1.3.6.1.4.1.3373.1103.80.19.1.4 | INTEGER {notActive(0), reset(1)} | read-write | current |
| linkBerTable OBJECT-TYPE Table with Command to estimate BER of radio equipment. Every objects in this table is not persistent. An Instance of this table is created on creation of linkStatusEntry | 1.3.6.1.4.1.3373.1103.80.20 | not-accessible | current | |
| linkBerEntry OBJECT-TYPE Radio equipment BER estimate record. | 1.3.6.1.4.1.3373.1103.80.20.1 | not-accessible | current | |
| linkBerErrorCounterH OBJECT-TYPE High 32 bit part of the 64 bit error counter. Bit 32-63. | 1.3.6.1.4.1.3373.1103.80.20.1.1 | Counter32 | read-only | current |
| linkBerErrorCounterL OBJECT-TYPE Low 32 bit part of the 64 bit error counter. Bit 0-31. | 1.3.6.1.4.1.3373.1103.80.20.1.2 | Counter32 | read-only | current |
| linkBerDataCounterH OBJECT-TYPE High 32 bit part of the 64 bit data counter. Bit 32-63. | 1.3.6.1.4.1.3373.1103.80.20.1.3 | Counter32 | read-only | current |
| linkBerDataCounterL OBJECT-TYPE Low 32 bit part of the 64 bit data counter. Bit 0-31. | 1.3.6.1.4.1.3373.1103.80.20.1.4 | Counter32 | read-only | current |
| linkBerSyncLossAlarm OBJECT-TYPE BER sync loss alarm. | 1.3.6.1.4.1.3373.1103.80.20.1.5 | AlarmStatus | read-only | current |
| linkBerSyncLossAlarmCounter OBJECT-TYPE BER sync loss events counter. | 1.3.6.1.4.1.3373.1103.80.20.1.6 | Integer32 | read-only | current |
| linkBerElapsedTime OBJECT-TYPE BER measure elapsed time. | 1.3.6.1.4.1.3373.1103.80.20.1.7 | Integer32 | read-only | current |
| linkAcmTable OBJECT-TYPE Table with link records. | 1.3.6.1.4.1.3373.1103.80.21 | not-accessible | current | |
| linkAcmEntry OBJECT-TYPE ACM entries. | 1.3.6.1.4.1.3373.1103.80.21.1 | not-accessible | current | |
| linkAcmProfileId OBJECT-TYPE This object identifies the profile number for the radio selected by the object linkAcmId. | 1.3.6.1.4.1.3373.1103.80.21.1.1 | Integer32 | read-only | current |
| linkAcmProfileModulation OBJECT-TYPE This object is the modulation of the profile. | 1.3.6.1.4.1.3373.1103.80.21.1.2 | BitsPerSymbol | read-only | current |
| linkAcmProfileCode OBJECT-TYPE This object is the type of codificator of the profile. | 1.3.6.1.4.1.3373.1103.80.21.1.3 | INTEGER {normal(1), strong(2)} | read-only | current |
| linkAcmProfileCapacity OBJECT-TYPE This object is used to contain total capacity of profile (in kbits/sec). | 1.3.6.1.4.1.3373.1103.80.21.1.4 | Integer32 | read-only | current |
| linkAcmProfileLabel OBJECT-TYPE ASCII string used to assign a name to profile. | 1.3.6.1.4.1.3373.1103.80.21.1.5 | DisplayString (SIZE(0..32)) | read-write | current |
| linkAcmProfileEnable OBJECT-TYPE The object is used to contain if the use of this profile is enabled or disabled | 1.3.6.1.4.1.3373.1103.80.21.1.6 | INTEGER {disable(1), enable(2)} | read-only | current |
| linkAcmMaxTDMCapacity OBJECT-TYPE This object reports the maximum capacity that can be assigned to the TDM traffic. The capacity is specified in number of E1 (2Mbit/s). This object has been superseded by linkE1vsSTM1CapacityTable. | 1.3.6.1.4.1.3373.1103.80.21.1.7 | Integer32 | read-only | deprecated |
| linkAcmPowerScaling OBJECT-TYPE This object contains the difference (in eighth of dB) between the TX power at this profile modulation and the TX power at the reference modulation. The power scaling value is achieved from the table linkPtxProfileTable. This object is deprecated: see combinedRadioPowerScalingTable. | 1.3.6.1.4.1.3373.1103.80.21.1.8 | Integer32 | read-only | deprecated |
| linkAcmDownshiftThreshold OBJECT-TYPE The object is used to contain the downshift threshold in dB/10. | 1.3.6.1.4.1.3373.1103.80.21.1.9 | Integer32 | read-only | current |
| linkAcmUpshiftThreshold OBJECT-TYPE The object is used to contain the upshift threshold in dB/10. | 1.3.6.1.4.1.3373.1103.80.21.1.10 | Integer32 | read-only | current |
| linkAcmActiveProfile OBJECT-TYPE This object is used to contain the active status of this profile. The value of the object is related to linkAcmRxProfile and linkAcmTxProfile of the LinkStatusEntry. | 1.3.6.1.4.1.3373.1103.80.21.1.11 | INTEGER {cleared(1), activeRx(2), activeTx(3), activeBoth(4)} | read-only | current |
| linkAcmTDMCapacity OBJECT-TYPE This object reports current TDM capacity (in kbits/sec) of the profile. | 1.3.6.1.4.1.3373.1103.80.21.1.12 | Integer32 | read-only | current |
| linkAcmETHCapacity OBJECT-TYPE This object reports current ETH capacity (in Kbits/sec) of the profile. | 1.3.6.1.4.1.3373.1103.80.21.1.13 | Integer32 | read-only | current |
| linkAcmAtpcRxPowerScaling OBJECT-TYPE This object contains the difference (in eighth of dB) between the ATPC RX level thresholds at this profile modulation and the ATPC RX level thresholds at the upper modulation. This object is deprecated: see combinedRadioPowerScalingTable. | 1.3.6.1.4.1.3373.1103.80.21.1.14 | Integer32 | read-only | deprecated |
| linkAcmPowerRange OBJECT-TYPE This object contains (in dB) the current value of ATPC range. This object is deprecated: see combinedRadioPowerScalingTable. | 1.3.6.1.4.1.3373.1103.80.21.1.15 | Integer32 | read-only | deprecated |
| linkProTable OBJECT-TYPE A list of protection link entries. This table was deprecated and replaced by linkProV2Table. It is a view of the rows of the linkProV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers | 1.3.6.1.4.1.3373.1103.80.22 | not-accessible | deprecated | |
| linkProEntry OBJECT-TYPE An entry containing management information applicable to a protected link. | 1.3.6.1.4.1.3373.1103.80.22.1 | not-accessible | deprecated | |
| linkProProtectionTxChIdx OBJECT-TYPE This object identifies the tx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. | 1.3.6.1.4.1.3373.1103.80.22.1.1 | Integer32 | read-create | deprecated |
| linkProProtectionRxChIdx OBJECT-TYPE This object identifies the rx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. | 1.3.6.1.4.1.3373.1103.80.22.1.2 | Integer32 | read-create | deprecated |
| linkProTxWtrTime OBJECT-TYPE It defines the Wait Time (in minutes) to Restore in transmission when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. | 1.3.6.1.4.1.3373.1103.80.22.1.3 | INTEGER (0..12) | read-create | deprecated |
| linkProRxWtrTime OBJECT-TYPE It defines the Wait Time (in minutes) to Restore in reception when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. | 1.3.6.1.4.1.3373.1103.80.22.1.4 | INTEGER (0..12) | read-create | deprecated |
| linkProTxSwitchedChIdx OBJECT-TYPE This object reports the index of tx channel switched to protection. This object is applicable only for N+1 protection schema. | 1.3.6.1.4.1.3373.1103.80.22.1.5 | Integer32 | read-only | deprecated |
| linkProRxSwitchedChIdx OBJECT-TYPE This object reports the index of rx channel switched to protection. This object is applicable only for N+1 protection schema. | 1.3.6.1.4.1.3373.1103.80.22.1.6 | Integer32 | read-only | deprecated |
| linkProTxRevertive OBJECT-TYPE It defines if tx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. | 1.3.6.1.4.1.3373.1103.80.22.1.7 | INTEGER {disable(1), enable(2)} | read-create | deprecated |
| linkProRxRevertive OBJECT-TYPE It defines if rx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. | 1.3.6.1.4.1.3373.1103.80.22.1.8 | INTEGER {disable(1), enable(2)} | read-create | deprecated |
| linkProExtraTraffic OBJECT-TYPE This object enables or disables the transfer of extra traffic on the protection channel in a N+1 link. This object must be set to disabled in case of architectures different for N+1. | 1.3.6.1.4.1.3373.1103.80.22.1.9 | INTEGER {disable(1), enable(2)} | read-create | deprecated |
| linkProRowStatus OBJECT-TYPE Status of this conceptual row in linkProTable. | 1.3.6.1.4.1.3373.1103.80.22.1.10 | RowStatus | read-create | deprecated |
| linkProMaintTable OBJECT-TYPE A list of maintenance commands for protected links. A row in this table is added on creation of a row in linkProTable. This table was deprecated and replaced by linkProMaintV2Table. It is a view of the rows of the linkProMaintV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers | 1.3.6.1.4.1.3373.1103.80.23 | not-accessible | deprecated | |
| linkProMaintEntry OBJECT-TYPE An entry containing maintenance commands applicable to a protected link. | 1.3.6.1.4.1.3373.1103.80.23.1 | not-accessible | deprecated | |
| linkProMaintTxLockout OBJECT-TYPE Command to enable/disable tx lockout. This object is applicable only in case of N+1 protections. | 1.3.6.1.4.1.3373.1103.80.23.1.1 | INTEGER {disable(1), enable(2)} | read-write | deprecated |
| linkProMaintRxLockout OBJECT-TYPE Command to enable/disable rx lockout. This object is applicable only in case of N+1 protections. | 1.3.6.1.4.1.3373.1103.80.23.1.2 | INTEGER {disable(1), enable(2)} | read-write | deprecated |
| linkProMaintTxForced OBJECT-TYPE Command to force switch to a given transmission channel. Zero value means no switch. | 1.3.6.1.4.1.3373.1103.80.23.1.3 | Integer32 | read-write | deprecated |
| linkProMaintRxForced OBJECT-TYPE Command to force switch to a given receiving channel. Zero value means no switch. | 1.3.6.1.4.1.3373.1103.80.23.1.4 | Integer32 | read-write | deprecated |
| linkProMaintTxWtrReset OBJECT-TYPE Clear wait time to restore making the revertive path immediately available. | 1.3.6.1.4.1.3373.1103.80.23.1.5 | INTEGER {notActive(1), on(2)} | read-write | deprecated |
| linkProMaintRxWtrReset OBJECT-TYPE Clear wait time to restore making the revertive path immediately available. | 1.3.6.1.4.1.3373.1103.80.23.1.6 | INTEGER {notActive(1), on(2)} | read-write | deprecated |
| linkCapabilitiesTable OBJECT-TYPE Table with RadioCapabilities entries: there is an entry for each linkTable row. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the capabilities of each channel. As such, this table is declared deprecated and replaced by combinedRadioCapabilitiesTable. | 1.3.6.1.4.1.3373.1103.80.24 | not-accessible | deprecated | |
| linkCapabilitiesEntry OBJECT-TYPE LinkCapabilities entry. | 1.3.6.1.4.1.3373.1103.80.24.1 | not-accessible | deprecated | |
| linkCapabilitiesCapability OBJECT-TYPE Bit map to describe the radio features. | 1.3.6.1.4.1.3373.1103.80.24.1.1 | RadioCapability | read-only | deprecated |
| linkCapabilitiesTxMinFrequency OBJECT-TYPE Minimum of available channel frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.24.1.2 | Integer32 | read-only | deprecated |
| linkCapabilitiesTxMaxFrequency OBJECT-TYPE Maximum of available channel frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.24.1.3 | Integer32 | read-only | deprecated |
| linkCapabilitiesStepFrequency OBJECT-TYPE Minimum frequency step in KHz. | 1.3.6.1.4.1.3373.1103.80.24.1.4 | Integer32 | read-only | deprecated |
| linkCapabilitiesMinPtxNominalValue OBJECT-TYPE Minimum nominal Ptx in dBm. | 1.3.6.1.4.1.3373.1103.80.24.1.5 | Integer32 | read-only | deprecated |
| linkCapabilitiesMaxPtxNominalValue OBJECT-TYPE Maximum nominal Ptx in dBm. | 1.3.6.1.4.1.3373.1103.80.24.1.6 | Integer32 | read-only | deprecated |
| linkCapabilitiesExtendedMinPwr OBJECT-TYPE Minimum extended Ptx power for fade margin. | 1.3.6.1.4.1.3373.1103.80.24.1.7 | Integer32 | read-only | deprecated |
| linkFrequencyTable OBJECT-TYPE Availables channels for selected channel spacing and modulation In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the allowable frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioFrequencyTable. | 1.3.6.1.4.1.3373.1103.80.25 | not-accessible | deprecated | |
| linkFreqTabEntry OBJECT-TYPE LinkFreqTab record. | 1.3.6.1.4.1.3373.1103.80.25.1 | not-accessible | deprecated | |
| linkFreqChannelId OBJECT-TYPE Index of the table | 1.3.6.1.4.1.3373.1103.80.25.1.1 | Integer32 | read-only | deprecated |
| linkFreqChannelNum OBJECT-TYPE Available channel number. | 1.3.6.1.4.1.3373.1103.80.25.1.2 | Integer32 | read-only | deprecated |
| linkFreqValue OBJECT-TYPE Frequency related to linkFreqChannelNum. | 1.3.6.1.4.1.3373.1103.80.25.1.3 | Integer32 | read-only | deprecated |
| linkDuplexFrequencyTable OBJECT-TYPE Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the allowable duplex frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioDuplexFrequencyTable. | 1.3.6.1.4.1.3373.1103.80.26 | not-accessible | deprecated | |
| linkDuplexFreqEntry OBJECT-TYPE Duplex Frequency entry. For each available duplex frequency | 1.3.6.1.4.1.3373.1103.80.26.1 | not-accessible | deprecated | |
| linkDuplexFreqId OBJECT-TYPE Index of the table. | 1.3.6.1.4.1.3373.1103.80.26.1.1 | Integer32 | read-only | deprecated |
| linkDuplexFreqValue OBJECT-TYPE Duplex frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.26.1.2 | Integer32 | read-only | deprecated |
| linkModulationTable OBJECT-TYPE List of modulation related to channel spacing. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. | 1.3.6.1.4.1.3373.1103.80.27 | not-accessible | current | |
| linkModulationEntry OBJECT-TYPE linkModulation record. | 1.3.6.1.4.1.3373.1103.80.27.1 | not-accessible | current | |
| linkChannelSpacing OBJECT-TYPE This object identifies the channel spacing. | 1.3.6.1.4.1.3373.1103.80.27.1.1 | ChannelSpacing | read-only | current |
| linkModulationMap OBJECT-TYPE List of modulation in the linkChanSpacing | 1.3.6.1.4.1.3373.1103.80.27.1.2 | ModulationMap | read-only | current |
| linkRefModulationMap OBJECT-TYPE List of modulations that can be selected as reference in the linkChanSpacingId | 1.3.6.1.4.1.3373.1103.80.27.1.3 | ModulationMap | read-only | current |
| combinedRadioCapabilitiesTable OBJECT-TYPE Table with RadioCapabilities entries: there is an entry for each radioSettingTable row. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios belonging to the link. In 1+1 FD radio link, managers have to know the allowable duplex frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioCapabilitiesTable. | 1.3.6.1.4.1.3373.1103.80.28 | not-accessible | current | |
| combinedRadioCapabilitiesEntry OBJECT-TYPE combinedRadioCapabilities entry. | 1.3.6.1.4.1.3373.1103.80.28.1 | not-accessible | current | |
| combinedRadioCapabilitiesCapability OBJECT-TYPE Bit map to describe the radio features. | 1.3.6.1.4.1.3373.1103.80.28.1.1 | RadioCapability | read-only | current |
| combinedRadioCapabilitiesTxMinFrequency OBJECT-TYPE Minimum of available channel frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.28.1.2 | Integer32 | read-only | current |
| combinedRadioCapabilitiesTxMaxFrequency OBJECT-TYPE Maximum of available channel frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.28.1.3 | Integer32 | read-only | current |
| combinedRadioCapabilitiesStepFrequency OBJECT-TYPE Minimum frequency step in KHz. | 1.3.6.1.4.1.3373.1103.80.28.1.4 | Integer32 | read-only | current |
| combinedRadioCapabilitiesMinPtxNominalValue OBJECT-TYPE Minimum nominal Ptx in dBm. | 1.3.6.1.4.1.3373.1103.80.28.1.5 | Integer32 | read-only | current |
| combinedRadioCapabilitiesMaxPtxNominalValue OBJECT-TYPE Maximum nominal Ptx in dBm. | 1.3.6.1.4.1.3373.1103.80.28.1.6 | Integer32 | read-only | current |
| combinedRadioCapabilitiesExtendedMinPwr OBJECT-TYPE Minimum extended Ptx power for fade margin. | 1.3.6.1.4.1.3373.1103.80.28.1.7 | Integer32 | read-only | current |
| combinedRadioFrequencyTable OBJECT-TYPE Availables channels for selected channel spacing and modulation In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. | 1.3.6.1.4.1.3373.1103.80.29 | not-accessible | current | |
| combinedRadioFreqTabEntry OBJECT-TYPE combinedRadioFreqTab record. | 1.3.6.1.4.1.3373.1103.80.29.1 | not-accessible | current | |
| combinedRadioFreqChannelId OBJECT-TYPE Index of the table | 1.3.6.1.4.1.3373.1103.80.29.1.1 | Integer32 | read-only | current |
| combinedRadioFreqChannelNum OBJECT-TYPE Available channel number. | 1.3.6.1.4.1.3373.1103.80.29.1.2 | Integer32 | read-only | current |
| combinedRadioFreqValue OBJECT-TYPE Frequency related to combinedRadioFreqChannelNum. | 1.3.6.1.4.1.3373.1103.80.29.1.3 | Integer32 | read-only | current |
| combinedRadioDuplexFrequencyTable OBJECT-TYPE Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. | 1.3.6.1.4.1.3373.1103.80.30 | not-accessible | current | |
| combinedRadioDuplexFreqEntry OBJECT-TYPE Duplex Frequency entry. There is an entry for each available duplex frequency. | 1.3.6.1.4.1.3373.1103.80.30.1 | not-accessible | current | |
| combinedRadioDuplexFreqId OBJECT-TYPE Index of the table. | 1.3.6.1.4.1.3373.1103.80.30.1.1 | Integer32 | read-only | current |
| combinedRadioDuplexFreqValue OBJECT-TYPE Duplex frequency in KHz. | 1.3.6.1.4.1.3373.1103.80.30.1.2 | Integer32 | read-only | current |
| combinedRadioPowerScalingTable OBJECT-TYPE List of modulation related to channel spacing. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. | 1.3.6.1.4.1.3373.1103.80.31 | not-accessible | current | |
| combinedRadioPowerScalingEntry OBJECT-TYPE radioPowerScaling record. | 1.3.6.1.4.1.3373.1103.80.31.1 | not-accessible | current | |
| combinedRadioPowerScaling OBJECT-TYPE This object contains the difference (in eighth of dB) between the TX power at this profile modulation and the TX power at the reference modulation. The power scaling value is achieved from the table linkPtxProfileTable. | 1.3.6.1.4.1.3373.1103.80.31.1.1 | Integer32 | read-only | current |
| combinedRadioAtpcRxPowerScaling OBJECT-TYPE This object contains the difference (in eighth of dB) between the ATPC RX level thresholds at this profile modulation and the ATPC RX level thresholds at the upper modulation. | 1.3.6.1.4.1.3373.1103.80.31.1.2 | Integer32 | read-only | current |
| combinedRadioPowerRange OBJECT-TYPE This object contains (in dB) the current value of ATPC range. | 1.3.6.1.4.1.3373.1103.80.31.1.3 | Integer32 | read-only | current |
| stm1BulkMappingTable OBJECT-TYPE Table with entries containing stm-1 bulk transport parameters for a particular link. For each link are present as many rows as the STM-1 that the link can carry in bulk mode. | 1.3.6.1.4.1.3373.1103.80.32 | not-accessible | current | |
| stm1BulkMappingEntry OBJECT-TYPE An row in stm1BulkSettingsTable. | 1.3.6.1.4.1.3373.1103.80.32.1 | not-accessible | current | |
| stm1BulkPolIndex OBJECT-TYPE Polarization index. | 1.3.6.1.4.1.3373.1103.80.32.1.1 | Integer32 | read-only | current |
| stm1BulkChanIndex OBJECT-TYPE STM-1 channel index. The range of this object is from 1 to N, where N is the number of STM-1 that a link can carry in bulk mode. | 1.3.6.1.4.1.3373.1103.80.32.1.2 | Integer32 | read-only | current |
| stm1BulkChannel OBJECT-TYPE Index of the stm-1 in stm1Table. The SNMP agent will accept only index of a STM-1 present in stm1Table with stm1Structure set to opaque(4). | 1.3.6.1.4.1.3373.1103.80.32.1.3 | Stm1IndexOrZero | read-write | current |
| linkE1vsSTM1CapacityTable OBJECT-TYPE Table with entries containing the E1 cpacity according to the tributaries STM-1 configured to be carried in bulk mode. | 1.3.6.1.4.1.3373.1103.80.33 | not-accessible | current | |
| linkE1vsSTM1CapacityEntry OBJECT-TYPE An row in linkE1vsSTM1CapacityTable. | 1.3.6.1.4.1.3373.1103.80.33.1 | not-accessible | current | |
| linkE1vsSTM1CapacityStm1 OBJECT-TYPE Number of tributaries STM-1 configured to be transported in bulk mode. | 1.3.6.1.4.1.3373.1103.80.33.1.1 | Integer32 | not-accessible | current |
| linkE1vsSTM1CapacityE1 OBJECT-TYPE Number of E1 that can be carried by this profile according to the the tributaries STM-1 carried in bulk mode. | 1.3.6.1.4.1.3373.1103.80.33.1.2 | Integer32 | read-only | current |
| linkTfcV2Table OBJECT-TYPE Transmitter Fail Check feature. In 1+1 HS configuration, the radio terminal that doesn't receive signals on both receivers, requests the remote transmitter switch. | 1.3.6.1.4.1.3373.1103.80.34 | not-accessible | current | |
| linkTfcV2Entry OBJECT-TYPE Radio link TFC entry. | 1.3.6.1.4.1.3373.1103.80.34.1 | not-accessible | current | |
| linkTfcV2Action OBJECT-TYPE reset: to clear the forced switch generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.34.1.1 | INTEGER {notActive(0), reset(1)} | read-create | current |
| linkTfcV2Control OBJECT-TYPE It enables the Tx switch from remote equipment (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.34.1.2 | INTEGER {disable(1), enable(2)} | read-create | current |
| linkTfcV2WatchWindow OBJECT-TYPE Watch Window (in seconds) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.34.1.3 | INTEGER (1..300) | read-create | current |
| linkTfcV2AlarmThreshold OBJECT-TYPE Alarm Threshold (number of seconds with both remote RX in fail) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.34.1.4 | INTEGER (1..60) | read-create | current |
| linkTfcV2Alarm OBJECT-TYPE Transmission switch alarm generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system). | 1.3.6.1.4.1.3373.1103.80.34.1.5 | AlarmStatus | read-only | current |
| linkTfcV2RowStatus OBJECT-TYPE Status of this conceptual row in linkTfcV2Table. | 1.3.6.1.4.1.3373.1103.80.34.1.6 | RowStatus | read-create | current |
| linkProV2Table OBJECT-TYPE A list of protection link entries. | 1.3.6.1.4.1.3373.1103.80.35 | not-accessible | current | |
| linkProV2Entry OBJECT-TYPE An entry containing management information applicable to a protected link. | 1.3.6.1.4.1.3373.1103.80.35.1 | not-accessible | current | |
| linkProV2ProtectionTxChIdx OBJECT-TYPE This object identifies the tx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. | 1.3.6.1.4.1.3373.1103.80.35.1.1 | Integer32 | read-create | current |
| linkProV2ProtectionRxChIdx OBJECT-TYPE This object identifies the rx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set. | 1.3.6.1.4.1.3373.1103.80.35.1.2 | Integer32 | read-create | current |
| linkProV2TxWtrTime OBJECT-TYPE It defines the Wait Time (in minutes) to Restore in transmission when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. | 1.3.6.1.4.1.3373.1103.80.35.1.3 | INTEGER (0..12) | read-create | current |
| linkProV2RxWtrTime OBJECT-TYPE It defines the Wait Time (in minutes) to Restore in reception when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set. | 1.3.6.1.4.1.3373.1103.80.35.1.4 | INTEGER (0..12) | read-create | current |
| linkProV2TxSwitchedChIdx OBJECT-TYPE This object reports the index of tx channel switched to protection. This object is applicable only for N+1 protection schema. | 1.3.6.1.4.1.3373.1103.80.35.1.5 | Integer32 | read-only | current |
| linkProV2RxSwitchedChIdx OBJECT-TYPE This object reports the index of rx channel switched to protection. This object is applicable only for N+1 protection schema. | 1.3.6.1.4.1.3373.1103.80.35.1.6 | Integer32 | read-only | current |
| linkProV2TxRevertive OBJECT-TYPE It defines if tx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. | 1.3.6.1.4.1.3373.1103.80.35.1.7 | INTEGER {disable(1), enable(2)} | read-create | current |
| linkProV2RxRevertive OBJECT-TYPE It defines if rx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive. | 1.3.6.1.4.1.3373.1103.80.35.1.8 | INTEGER {disable(1), enable(2)} | read-create | current |
| linkProV2ExtraTraffic OBJECT-TYPE This object enables or disables the transfer of extra traffic on the protection channel in a N+1 link. This object must be set to disabled in case of architectures different for N+1. | 1.3.6.1.4.1.3373.1103.80.35.1.9 | INTEGER {disable(1), enable(2)} | read-create | current |
| linkProV2RowStatus OBJECT-TYPE Status of this conceptual row in linkProV2Table. | 1.3.6.1.4.1.3373.1103.80.35.1.10 | RowStatus | read-create | current |
| linkProMaintV2Table OBJECT-TYPE A list of maintenance commands for protected links. A row in this table is added on creation of a row in linkProV2Table. | 1.3.6.1.4.1.3373.1103.80.36 | not-accessible | current | |
| linkProMaintV2Entry OBJECT-TYPE An entry containing maintenance commands applicable to a protected link. | 1.3.6.1.4.1.3373.1103.80.36.1 | not-accessible | current | |
| linkProMaintV2TxLockout OBJECT-TYPE Command to enable/disable tx lockout. This object is applicable only in case of N+1 protections. | 1.3.6.1.4.1.3373.1103.80.36.1.1 | INTEGER {disable(1), enable(2)} | read-write | current |
| linkProMaintV2RxLockout OBJECT-TYPE Command to enable/disable rx lockout. This object is applicable only in case of N+1 protections. | 1.3.6.1.4.1.3373.1103.80.36.1.2 | INTEGER {disable(1), enable(2)} | read-write | current |
| linkProMaintV2TxForced OBJECT-TYPE Command to force switch to a given transmission channel. Zero value means no switch. | 1.3.6.1.4.1.3373.1103.80.36.1.3 | Integer32 | read-write | current |
| linkProMaintV2RxForced OBJECT-TYPE Command to force switch to a given receiving channel. Zero value means no switch. | 1.3.6.1.4.1.3373.1103.80.36.1.4 | Integer32 | read-write | current |
| linkProMaintV2TxWtrReset OBJECT-TYPE Clear wait time to restore making the revertive path immediately available. | 1.3.6.1.4.1.3373.1103.80.36.1.5 | INTEGER {notActive(1), on(2)} | read-write | current |
| linkProMaintV2RxWtrReset OBJECT-TYPE Clear wait time to restore making the revertive path immediately available. | 1.3.6.1.4.1.3373.1103.80.36.1.6 | INTEGER {notActive(1), on(2)} | read-write | current |
| sspTable OBJECT-TYPE A list of operative and administrative set of parameters. This table holds three row for every link (and its polarizations) configured in the NE: 1) administative parameters of local NE 2) operative parameters of local NE 3) administative parameters of remote NE | 1.3.6.1.4.1.3373.1103.80.37 | not-accessible | current | |
| sspEntry OBJECT-TYPE An entry containing SSP relevant parameters. | 1.3.6.1.4.1.3373.1103.80.37.1 | not-accessible | current | |
| sspParameterType OBJECT-TYPE This object identifies what parameters are for. | 1.3.6.1.4.1.3373.1103.80.37.1.1 | INTEGER {localAdminStatus(1), localOperStatus(2), remoteAdminStatus(3)} | not-accessible | current |
| sspLinkBandwidth OBJECT-TYPE Link Bandwidth (channel spacing). | 1.3.6.1.4.1.3373.1103.80.37.1.2 | INTEGER {sspBw3p5Mhz(0), sspBw7MHz(1), sspBw14MHz(2), sspBw28MHz(3), sspBw56MHz(4), sspBw10MHz(5), sspBw20MHz(6), sspBw30MHz(7), sspBw40MHz(8), sspBw50MHz(9), sspBw112Mhz(10), sspBw250Mhz(11), sspBw500Mhz(12), sspBw750Mhz(13), sspBw1Ghz(14), sspBw60MHz(15), sspBw80MHz(16)} | read-only | current |
| sspLinkModulation OBJECT-TYPE Link reference modulation. | 1.3.6.1.4.1.3373.1103.80.37.1.3 | INTEGER {sspModBPSK(1), sspMod4QAM(2), sspMod8PSK(3), sspMod16QAM(4), sspMod32QAM(5), sspMod64QAM(6), sspMod128QAM(7), sspMod256QAM(8), sspMod512QAM(9), sspMod1024QAM(10), sspMod2048QAM(11), sspMod4096QAM(12)} | read-only | current |
| sspLinkAcmEngineEnable OBJECT-TYPE This object is used to enable/disable the ACM engine. | 1.3.6.1.4.1.3373.1103.80.37.1.4 | INTEGER {disable(1), enable(2)} | read-only | current |
| sspLinkTxUpperProfile OBJECT-TYPE The object (and linkTxLowerProfile object) is used to restrict the TX profile range when ACM is enabled. | 1.3.6.1.4.1.3373.1103.80.37.1.5 | INTEGER | read-only | current |
| sspLinkTxLowerProfile OBJECT-TYPE The object (and linkTxUpperProfile object) is used to restrict the TX profile range when ACM is enabled. | 1.3.6.1.4.1.3373.1103.80.37.1.6 | INTEGER | read-only | current |
| sspLinkSynchSetupProtocolEnable OBJECT-TYPE Synchronization Setup Protocol (SSP) control. | 1.3.6.1.4.1.3373.1103.80.37.1.7 | INTEGER {disable(1), enable(2)} | read-only | current |
| sspLinkProfilesSetSelection OBJECT-TYPE Selection of the working profile set between high gain (max robustness) profile set and high throughput (max capacity) profile set. The set of profiles high gain features a greater robustness against to the set of profiles high throughput. For radio systems that do not have more sets of profiles, this object becomes read only and its reading shows the only one set of profiles supported. | 1.3.6.1.4.1.3373.1103.80.37.1.8 | INTEGER {highThroughput(1), highGain(2)} | read-only | current |
| sspTdmE1Channel OBJECT-TYPE Number of E1 channels. This object is used to define the capacity of E1 tributaries assigned to a given radio link. The capacity is changed in steps of E1 (2Mbit/s). | 1.3.6.1.4.1.3373.1103.80.37.1.9 | Integer32 | read-only | current |
| sspTdmStm1Channel OBJECT-TYPE Number of STM-1 channels transported in bulk mode. | 1.3.6.1.4.1.3373.1103.80.37.1.10 | Integer32 | read-only | current |
| radioLoopCapabilityTable OBJECT-TYPE This table shows which group a radio loop belongs to. Radios with the same group number (identifier) close loop simultaneously. | 1.3.6.1.4.1.3373.1103.80.38 | not-accessible | current | |
| radioLoopCapabilityEntry OBJECT-TYPE An entry containing a group identifier for each radio loop type. | 1.3.6.1.4.1.3373.1103.80.38.1 | not-accessible | current | |
| radioLoopRfGroup OBJECT-TYPE The group to which the radio RF loop belong to. | 1.3.6.1.4.1.3373.1103.80.38.1.1 | Integer32 | read-only | current |
| radioLoopIqGroup OBJECT-TYPE The group to which the radio IQ loop belong to. | 1.3.6.1.4.1.3373.1103.80.38.1.2 | Integer32 | read-only | current |
| radioLoopBaseBandGroup OBJECT-TYPE The group to which the radio base loop belong to. | 1.3.6.1.4.1.3373.1103.80.38.1.3 | Integer32 | read-only | current |
| radioRxBerThresholdTable OBJECT-TYPE This table shows the nominal and measured values of RX power at a bit error rate (BER) equal to 10e-6. | 1.3.6.1.4.1.3373.1103.80.39 | not-accessible | current | |
| radioRxBerThresholdEntry OBJECT-TYPE An entry containing the RX power thresholds. | 1.3.6.1.4.1.3373.1103.80.39.1 | not-accessible | current | |
| radioRxBerThresholdStatus OBJECT-TYPE This object shows whether the following objects are significant. | 1.3.6.1.4.1.3373.1103.80.39.1.1 | INTEGER {nonValid(1), valid(2)} | read-only | current |
| radioNominalRxBerThreshold OBJECT-TYPE The nominal value of RX power @ BER equal to 10e-6 | 1.3.6.1.4.1.3373.1103.80.39.1.2 | Integer32 | read-only | current |
| radioMeasuredRxBerThreshold OBJECT-TYPE The measured value of RX power @ BER equal to 10e-6. | 1.3.6.1.4.1.3373.1103.80.39.1.3 | Integer32 | read-only | current |
| radioRemDemodulatorFailAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioRemDemodulatorFailAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.50 | AlarmSeverityCode | read-write | current |
| radioRxActiveStatusTrapNotification OBJECT-TYPE Enable/disables (statusTrapEnable or statusTrapDisable) the trap generation on status change event for radioRxActivestatus | 1.3.6.1.4.1.3373.1103.80.51 | INTEGER {trapDisable(1), trapEnable(2)} | read-write | current |
| radioTxActiveStatusTrapNotification OBJECT-TYPE Define the severity associated to the radioTxActivestatus and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.52 | INTEGER {trapDisable(1), trapEnable(2)} | read-write | current |
| radioCableOpenAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioCableOpen and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.53 | AlarmSeverityCode | read-write | current |
| radioCableShortAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioCableShort and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.54 | AlarmSeverityCode | read-write | current |
| radioInvalidFrequencyAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioInvalidFrequencyAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.55 | AlarmSeverityCode | read-write | current |
| radioBaseBandRxAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioBaseBandRxAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.56 | AlarmSeverityCode | read-write | current |
| radioModulatorFailAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioModulatorFailAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.57 | AlarmSeverityCode | read-write | current |
| radioDemodulatorFailAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioDemodulatorFailAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.58 | AlarmSeverityCode | read-write | current |
| radioRxPowerLowAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioRxPowerLowAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.59 | AlarmSeverityCode | read-write | current |
| radioTxPowerLowAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioTxPowerLowAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.60 | AlarmSeverityCode | read-write | current |
| radioVcoFailAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioVcoFailAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.61 | AlarmSeverityCode | read-write | current |
| radioRxIFAgcAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioRxIFAgcAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.62 | AlarmSeverityCode | read-write | current |
| radioTxIFAgcAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioTxIFAgcAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.63 | AlarmSeverityCode | read-write | current |
| radioIduOduCommunicationAlarmSeverityCode OBJECT-TYPE Define the severity associated to the radioIduOduCommunicationAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.64 | AlarmSeverityCode | read-write | current |
| radioOduIduCommunicationAlarmSeverityCode OBJECT-TYPE Define the severity associated to the radioOduIduCommunicationAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.65 | AlarmSeverityCode | read-write | current |
| radioLocalOduAlarmSynthesisSeverityCode OBJECT-TYPE Define the severity associated to the radioLocalOduAlarmSynthesis and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.66 | AlarmSeverityCode | read-write | current |
| radioRemoteOduAlarmSynthesisSeverityCode OBJECT-TYPE Define the severity associated to the radioRemoteOduAlarmSynthesis and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.67 | AlarmSeverityCode | read-write | current |
| radioConfigMismatchAlarmSeverityCode OBJECT-TYPE Defines the severity associated to the radioConfigMismatchAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.68 | AlarmSeverityCode | read-write | current |
| radioPrxHysteresisValue OBJECT-TYPE Defines the delta value associated to the radioPrx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed. | 1.3.6.1.4.1.3373.1103.80.69 | Integer32 | read-write | current |
| radioPtxHysteresisValue OBJECT-TYPE Defines the delta value associated to the radioPtx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed. | 1.3.6.1.4.1.3373.1103.80.70 | Integer32 | read-write | current |
| radioPrxHysteresisValueTrapNotification OBJECT-TYPE Enables/disables the Rx change trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.71 | INTEGER {trapDisable(1), trapEnable(2)} | read-write | current |
| radioPtxHysteresisValueTrapNotification OBJECT-TYPE Enables/disables the Tx change trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.72 | INTEGER {trapDisable(1), trapEnable(2)} | read-write | current |
| radioRxQualityLowAlarmSeverityCode OBJECT-TYPE Define the severity associated to the radioRxQualityLowAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.73 | AlarmSeverityCode | read-write | current |
| radioRxQualityWarningAlarmSeverityCode OBJECT-TYPE Define the severity associated to the radioRxQualityWarningAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.74 | AlarmSeverityCode | read-write | current |
| linkReducedCapacityAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkReducedCapacityAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.75 | AlarmSeverityCode | read-write | current |
| linkLinkTelemetryFailAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkLinkTelemetryFailAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.76 | AlarmSeverityCode | read-write | current |
| linkIdMismatchAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkIdMismatchAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.77 | AlarmSeverityCode | read-write | current |
| linkRadioEocAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkRadioEocAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.78 | AlarmSeverityCode | read-write | current |
| linkSetupMismatchAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkSetupMismatchAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.79 | AlarmSeverityCode | read-write | current |
| linkRescueSetupAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkRescueSetupAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.80 | AlarmSeverityCode | read-write | current |
| linkXpicProcedureBlockAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkXpicProcedureBlockAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.81 | AlarmSeverityCode | read-write | current |
| linkXpicRemTxOffAlarmAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkXpicRemTxOffAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.82 | AlarmSeverityCode | read-write | current |
| linkLocalIduAlarmSynthesis OBJECT-TYPE Synthesis of the local IDU alarms | 1.3.6.1.4.1.3373.1103.80.83 | AlarmStatus | read-only | current |
| linkLocalIduAlarmSynthesisSeverityCode OBJECT-TYPE Define the severity associated to the linkLocalIduAlarmSynthesis and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.84 | AlarmSeverityCode | read-write | current |
| linkRemoteIduAlarmSynthesisSeverityCode OBJECT-TYPE Define the severity associated to the linkLocalIduAlarmSynthesis and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.85 | AlarmSeverityCode | read-write | current |
| linkTfcAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkTfcV2Alarm (linkTfcAlarm) and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.86 | AlarmSeverityCode | read-write | current |
| linkBerSyncLossAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkBerSyncLossAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.87 | AlarmSeverityCode | read-write | current |
| linkNotMatchingRadiosAlarmSeverityCode OBJECT-TYPE Define the severity associated to the linkNotMatchingRadiosAlarm and enable/disable the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.80.88 | AlarmSeverityCode | read-write | current |
| channelSpacingSelection OBJECT-TYPE his object selects which channel spacings the radio link has to support: - etsi: Compliant with European Telecommunication Standards Institute - fcc: Compliant with Federal Communications Commission | 1.3.6.1.4.1.3373.1103.80.89 | Bits {etsi(0), fcc(1)} | read-write | current |
| fadeMarginMeasure OBJECT-TYPE Set by manager to start/stop fade margin measure. This item is linked to a manual operation (ManOpRecord) instance. | 1.3.6.1.4.1.3373.1103.80.90 | INTEGER {disable(1), enable(2)} | read-write | current |
| linkConfigurationInProgressTrapNotification OBJECT-TYPE Enable/disables (statusTrapEnable or statusTrapDisable) the trap generation on status change event for linkConfigurationInProgress | 1.3.6.1.4.1.3373.1103.80.91 | INTEGER {trapDisable(1), trapEnable(2)} | read-write | current |
Notifications
| Name | OID | Status |
|---|---|---|
| radioPrxChange NOTIFICATION-TYPE This event is generated when radioPrx is changed, in modulus, more than radioPtxHysteresisValue from last TRAP. The data passed with the event are: 1) equipIpSnmpAgentAddress - agent IP address 2) radioIndex - branch index 3) radioName - user assinged name 4) radioPrx - PRX value | 1.3.6.1.4.1.3373.1103.0.8001 | current |
| radioPtxChange NOTIFICATION-TYPE This event is generated when radioPtx is changed, in modulus, more than radioPtxHysteresisValue from last TRAP. The data passed with the event are: 1) equipIpSnmpAgentAddress - agent IP address 2) radioIndex - branch index 3) radioName - user assigned name 4) radioPtx - PTX value | 1.3.6.1.4.1.3373.1103.0.8002 | current |