MIBs Depot

SIAE-RADIO-SYSTEM-MIB

Registered at
1.3.6.1.4.1.3373.1103.80
Last updated
2016-07-14 00:00
Organization
SIAE MICROELETTRONICA spa
Revisions
2016-07-14 00:00, 2016-02-29 00:00, 2015-09-15 00:00, 2015-06-18 00:00, 2015-03-23 00:00, 2014-11-05 00:00, 2014-09-16 00:00, 2014-04-01 00:00
Namespace
siae
Source file
SIAE-RADIO-SYSTEM-MIB
Digest
sha256:6122532b0d3de2594182fa3127e90fc78762fadb50d07ff1cbd7732dc47cf75d

Description

Radio System MIB.

Contact

SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: help@siaemic.com

Imports

FromSymbols
IF-MIBInterfaceIndexOrZero
SIAE-ALARM-MIBAlarmSeverityCode, AlarmStatus, alarmTrap
SIAE-EQUIP-MIBequipIpSnmpAgentAddress
SIAE-TREE-MIBsiaeMib
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, RowStatus, StorageType, TEXTUAL-CONVENTION

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SIAE-ALARM-MIB
SIAE-EQUIP-MIB
SIAE-EQUIPTYPE-MIB
SIAE-RADIO-SYSTEM-MIB
SIAE-TREE-MIB
SIAE-USER-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
BitsPerSymbol
TEXTUAL-CONVENTION
his TC describes a data type which identifies a RF channel spacing.
current
ChannelSpacing
TEXTUAL-CONVENTION
This TC describes a data type which identifies a RF channel spacing.
current
ConfigMismatchReason
TEXTUAL-CONVENTION
This data type is used to specify the cause of Config Mismatch Alarm, that is the mismatch between the radio link capability and the current local and remote configuration. - securityMismatch(0) Copyright violation - frequencyFailMismatch(1) Configured frequency is out of Filter-Bandwidth - frequencyAlertMismatch(2) Configured frequency across Filter-Bandwidth - ptxMismatch(3) Tx power configured incongruent with RF Tx power limits - channelSpacingAndModulationMismatch(4) Bandwidth and/or modulation configured is invalid (RF doesn't support it) - remoteConfigurationMismatch(5) Incongruence between the couple of Terminal Radio Unit (TRU) in the link: - Frequency Incongruent (Freq) - Reference Bandwidth and Modulation incongruent - Acm-Tx map in congruent with remote Acm-Rx map - acmMismatch(6) Obsolete (no longer used) - profileSetMismatch(7) The selected profile set is not supported by the TRU
current
ModulationMap
TEXTUAL-CONVENTION
This data type is used as the syntax of the radioBranchModulationMap and radioBranchRefModulationMap objects.
current
RadioCapability
TEXTUAL-CONVENTION
This data type is used as the syntax of the radioBranchKeyFeatures objects.
current
Stm1IndexOrZero
TEXTUAL-CONVENTION
This textual convention permits the additional value of zero to an stm1Index in stm1Table. The value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where stm-1 was unknown, or when none or all stm-1s need to be referenced.
current

Objects

NameOIDSyntaxAccessStatus
radioSystemMibVersion
OBJECT-TYPE
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
1.3.6.1.4.1.3373.1103.80.1INTEGERread-onlycurrent
radioTable
OBJECT-TYPE
A list of radio interface entries. This table is useful to show the manager all the available radio interfaces on the equipment. Moreover it is a reference for Performance Monitoring (PWR and G828).
1.3.6.1.4.1.3373.1103.80.2not-accessiblecurrent
radioEntry
OBJECT-TYPE
An entry containing management information applicable to a particular radio interface.
1.3.6.1.4.1.3373.1103.80.2.1not-accessiblecurrent
radioIndex
OBJECT-TYPE
A unique value, greater than zero, for each radio interface. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.3373.1103.80.2.1.1Integer32read-onlycurrent
radioLabel
OBJECT-TYPE
A textual string containing information about the radio interface. This string should include the name of the manufacturer, the product name and the version of the interface hardware/software.
1.3.6.1.4.1.3373.1103.80.2.1.2DisplayString (SIZE(0..32))read-onlycurrent
radioType
OBJECT-TYPE
The type of interface.
1.3.6.1.4.1.3373.1103.80.2.1.3INTEGER {other(1), analogRadio(2), digitalRadio(3), xpicRadio(4)}read-onlycurrent
radioIfIndex
OBJECT-TYPE
This object defines a greater than zero value to identify an interface in ifTable or a zero value if ifTable is not supported.
1.3.6.1.4.1.3373.1103.80.2.1.4InterfaceIndexOrZeroread-onlycurrent
radioStorageType
OBJECT-TYPE
The storage type of this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row.
1.3.6.1.4.1.3373.1103.80.2.1.5StorageTyperead-onlycurrent
xpicTable
OBJECT-TYPE
A list of xpic radio interface entries. If a manager wants to make an xpic link, it should only add a particular xpic radio interface to an xpic link.
1.3.6.1.4.1.3373.1103.80.3not-accessiblecurrent
xpicEntry
OBJECT-TYPE
An entry containing management information applicable to a particular xpic radio interface.
1.3.6.1.4.1.3373.1103.80.3.1not-accessiblecurrent
xpicIndex
OBJECT-TYPE
A unique value, greater than zero, for each xpic radio interface. It is recommended that values are assigned contiguously starting from 1.
1.3.6.1.4.1.3373.1103.80.3.1.1Integer32read-onlycurrent
xpicRadioIdx
OBJECT-TYPE
Index of xpic radio interface, corresponding to an available xpic radio interface in radioTable.
1.3.6.1.4.1.3373.1103.80.3.1.2Integer32read-createcurrent
xpicRowstatus
OBJECT-TYPE
Status of this conceptual row in xpicTable.
1.3.6.1.4.1.3373.1103.80.3.1.3RowStatusread-createcurrent
xpicChTable
OBJECT-TYPE
A list of xpic channel entries. This table maps each xpic radio in respective xpic radio interface.
1.3.6.1.4.1.3373.1103.80.4not-accessiblecurrent
xpicChEntry
OBJECT-TYPE
An entry containing management information applicable to a particular xpic channel. It defines radio interface and polarization for a given xpic channel.
1.3.6.1.4.1.3373.1103.80.4.1not-accessiblecurrent
xpicChPolIndex
OBJECT-TYPE
This object identifies the xpic radio polarization.
1.3.6.1.4.1.3373.1103.80.4.1.1Integer32 (1..2)read-onlycurrent
xpicChRadioIdx
OBJECT-TYPE
Xpic radio interface, corresponding to a radio interface in radioTable, used to make up the given xpic radio interface.
1.3.6.1.4.1.3373.1103.80.4.1.2Integer32read-createcurrent
xpicChRowstatus
OBJECT-TYPE
Status of this conceptual row in xpicChTable.
1.3.6.1.4.1.3373.1103.80.4.1.3RowStatusread-createcurrent
linkAvailableIndex
OBJECT-TYPE
Shows an index which is available for creation of a new link in the system. It shows the smallest available index. Any attempt to create a link with a different index results in a failure.
1.3.6.1.4.1.3373.1103.80.5Integer32read-onlycurrent
linkTable
OBJECT-TYPE
A list of link entries.
1.3.6.1.4.1.3373.1103.80.6not-accessiblecurrent
linkEntry
OBJECT-TYPE
An entry containing management information applicable to a particular link.
1.3.6.1.4.1.3373.1103.80.6.1not-accessiblecurrent
linkIndex
OBJECT-TYPE
A unique value, greater than zero, for each link. Manager must use the first available index, suggested by linkAvailableIndex.
1.3.6.1.4.1.3373.1103.80.6.1.1Integer32read-onlycurrent
linkType
OBJECT-TYPE
This object identifies link type. Supported link types are: single link, 1+1 Hot Standby, 1+1 Frequency Diversity, 2+0 XPIC, 2+2 XPIC Hot Standby, 2+2 XPIC Frequency Diversity and N+1.
1.3.6.1.4.1.3373.1103.80.6.1.2INTEGER {radio1p0(1), radio1p1HS(2), radio1p1FD(3), radio2p0Xpic(4), radio2p2XpicHS(5), radio2p2XpicFD(6), radioNp1(7)}read-createcurrent
linkLabel
OBJECT-TYPE
A textual string containing information about the link. This string should give more details about link specific parameters.
1.3.6.1.4.1.3373.1103.80.6.1.3DisplayString (SIZE(0..32))read-createcurrent
linkIfIndex
OBJECT-TYPE
This object defines a greater than zero value to identify a link in ifTable or a zero value if ifTable is not supported.
1.3.6.1.4.1.3373.1103.80.6.1.4InterfaceIndexOrZeroread-onlycurrent
linkRowstatus
OBJECT-TYPE
Status of this row of linkTable. This object is used to manage the creation and deletion of conceptual rows in linkTable. To create a row in this table, a manager should set rowstatus to createAndWait(5) and choose a link type. Respective entries in linkSettingsTable, linkStatusTable and tdmSettingsTable will be created by agent.In case of protection links proper entries in linkProtectionTable will be also created. Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of rowstatus is notReady(3). When there is sufficient information to (attempt to) make the conceptual row available for use by the managed device, then the rowstatus column turns into notInService(2); manager must set rowstatus to active(1) to make the conceptual row active. The contents of linkSettingsTable and radioSettingsTable can be changed only if this object is notInService(2).
1.3.6.1.4.1.3373.1103.80.6.1.5RowStatusread-createcurrent
linkChTable
OBJECT-TYPE
A list of link channel entries.
1.3.6.1.4.1.3373.1103.80.7not-accessiblecurrent
linkChEntry
OBJECT-TYPE
An entry containing management information applicable to a particular link channel.
1.3.6.1.4.1.3373.1103.80.7.1not-accessiblecurrent
linkChIndex
OBJECT-TYPE
Link Channel Index.
1.3.6.1.4.1.3373.1103.80.7.1.1Integer32read-onlycurrent
linkChRadioIdx
OBJECT-TYPE
Radio channel index that corresponds to an available radio interface in radioTable.
1.3.6.1.4.1.3373.1103.80.7.1.2Integer32read-createcurrent
linkChRadioSettingsIdx
OBJECT-TYPE
Radio Settings Index. This object is a foreign key for a corresponding radioSettingsTable entry, which is automatically created by agent.
1.3.6.1.4.1.3373.1103.80.7.1.3Integer32read-createcurrent
linkChRowstatus
OBJECT-TYPE
Status of this row of linkChTable. This object is used to manage the creation and deletion of conceptual rows in linkChTable. To create a row in this table, a manager should set rowstatus to createAndWait(5). Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of rowstatus is notReady(3). When there is sufficient information to (attempt to) make the conceptual row available for use by the managed device, then the rowstatus column turns into notInService(2); manager must set rowstatus to active(1) to make the conceptual row active. The content of radioSettingsTable can be changed only if this object is notInService(2).
1.3.6.1.4.1.3373.1103.80.7.1.4RowStatusread-createcurrent
linkSettingsTable
OBJECT-TYPE
Table with link settings entries. This table contains all parameters of a radio frequency link. The content of this table can be changed by a manager if linkRowStatus is notInService(2).
1.3.6.1.4.1.3373.1103.80.8not-accessiblecurrent
linkSettingsEntry
OBJECT-TYPE
Radio link entry
1.3.6.1.4.1.3373.1103.80.8.1not-accessiblecurrent
linkBandwidthAndModulation
OBJECT-TYPE
Link Modulation and Bandwidth (channel spacing). The value of this object value is computed by: 65536*modulation+bandwidth where bandwidth selection is: 0 = 3.5Mhz 1 = 7MHz 2 = 14MHz 3 = 28MHz 4 = 56MHz 5 = 10MHz 6 = 20MHz 7 = 30MHz 8 = 40MHz 9 = 50MHz 10 = 112Mhz 11 = 250Mhz 12 = 500Mhz 13 = 750Mhz 14 = 1Ghz 15 = 60MHz 16 = 80MHz and modulation is in bit-per-symbol: 1 = BPSK 2 = 4QAM 3 = 8PSK 4 = 16QAM 5 = 32QAM 6 = 64QAM 7 = 128QAM 8 = 256QAM 9 = 512QAM 10 = 1024QAM 11 = 2048QAM. 12 = 4096QAM. Examples: 250Mhz-4QAM (131083), 500Mhz-4QAM (131084), 250Mhz-16QAM (262155), 500Mhz-64QAM (393228). Note: 0 bit-per-symbol is not possible, so value 0 is used for BandwidthAndModulation unassigned.
1.3.6.1.4.1.3373.1103.80.8.1.1Integer32read-createcurrent
linkAcmEngineEnable
OBJECT-TYPE
This object is used to enable/disable the ACM engine
1.3.6.1.4.1.3373.1103.80.8.1.2INTEGER {disable(1), enable(2)}read-createcurrent
linkTxUpperProfile
OBJECT-TYPE
The object (and linkTxLowerProfile object) is used to restrict the TX profile range when ACM is enabled.
1.3.6.1.4.1.3373.1103.80.8.1.3INTEGERread-createcurrent
linkTxLowerProfile
OBJECT-TYPE
The object (and linkTxUpperProfile object) is used to restrict the TX profile range when ACM is enabled.
1.3.6.1.4.1.3373.1103.80.8.1.4INTEGERread-createcurrent
linkId
OBJECT-TYPE
Link Identification (value 0..255)
1.3.6.1.4.1.3373.1103.80.8.1.5INTEGER (0..255)read-createcurrent
linkTxPwrThresh
OBJECT-TYPE
Threshold (value +3 , +15 dB) relative to nominal value of the TX power below wich the related alarm is set.
1.3.6.1.4.1.3373.1103.80.8.1.6INTEGER (3..15)read-createcurrent
linkRxPwrThresh
OBJECT-TYPE
Threshold (value -40 , -99 dBm) for RX power below wich the related alarm is set.
1.3.6.1.4.1.3373.1103.80.8.1.7INTEGER (-99..-40)read-createcurrent
linkSynchSetupProtocolEnable
OBJECT-TYPE
Synchronization Setup Protocol (SSP) control
1.3.6.1.4.1.3373.1103.80.8.1.8INTEGER {disable(1), enable(2)}read-createcurrent
linkProfilesSetSelection
OBJECT-TYPE
Selection of the working profile set between high gain (max robustness) profile set and high throughput (max capacity) profile set. The set of profiles high gain features a greater robustness against to the set of profiles high throughput. For radio systems that do not have more sets of profiles, this object becomes read only and its reading shows the only one set of profiles supported.
1.3.6.1.4.1.3373.1103.80.8.1.9INTEGER {highThroughput(1), highGain(2)}read-createcurrent
linkXpicControlProcedure
OBJECT-TYPE
Set by manager to enable\disable XPIC alarm control procedure. Only for XPIC configurations.
1.3.6.1.4.1.3373.1103.80.8.1.10INTEGER {disable(1), enable(2)}read-createcurrent
radioSettingsTable
OBJECT-TYPE
Table with radio settings entries. This table contains all parameters of a radio terminal. The content of this table can be changed only linkRowStatus is notInService(2)
1.3.6.1.4.1.3373.1103.80.9not-accessiblecurrent
radioSettingsEntry
OBJECT-TYPE
Radio terminal entry
1.3.6.1.4.1.3373.1103.80.9.1not-accessiblecurrent
radioSettingsIndex
OBJECT-TYPE
Radio settings index.
1.3.6.1.4.1.3373.1103.80.9.1.1Integer32read-onlycurrent
radioSettingsRowStatus
OBJECT-TYPE
Status of this row.
1.3.6.1.4.1.3373.1103.80.9.1.2RowStatusread-createcurrent
radioSettingsLabel
OBJECT-TYPE
A textual string containing information about the radio interface.
1.3.6.1.4.1.3373.1103.80.9.1.3DisplayString (SIZE(0..32))read-onlycurrent
radioTxFrequency
OBJECT-TYPE
Transmitted frequency in KHz. Null value means invalid frequency.
1.3.6.1.4.1.3373.1103.80.9.1.4INTEGERread-createcurrent
radioDuplexFrequency
OBJECT-TYPE
Value of duplex frequency in KHz. -2 means not set.
1.3.6.1.4.1.3373.1103.80.9.1.5INTEGERread-createcurrent
radioTxAttenuation
OBJECT-TYPE
Transmitter attenuation relative to nominal power (dBm).
1.3.6.1.4.1.3373.1103.80.9.1.6INTEGERread-createcurrent
radioAtpcManual
OBJECT-TYPE
Enables/disables Atpc Manual operation.
1.3.6.1.4.1.3373.1103.80.9.1.7INTEGER {disable(1), enable(2)}read-createcurrent
radioAtpcPwrHigh
OBJECT-TYPE
ATPC Control - Local Rx Power High (dBm range -30 to -80) -.
1.3.6.1.4.1.3373.1103.80.9.1.8Integer32read-createcurrent
radioAtpcPwrLow
OBJECT-TYPE
ATPC Control - Local Rx Power Low (dBm range -30 to -80) -.
1.3.6.1.4.1.3373.1103.80.9.1.9Integer32read-createcurrent
radioAtpcRange
OBJECT-TYPE
Defines the range of the ATPC regulation (expressed in dB) with respect to the current value of maximum Tx output, that is intended as the upper limit of the range. A null value means no limit: the lower limit of the range is equal to minimum Ptx.
1.3.6.1.4.1.3373.1103.80.9.1.10Integer32read-createcurrent
radioFreqTableSelection
OBJECT-TYPE
RadioFrequencyTable key (channel spacing & modulation) selection.
1.3.6.1.4.1.3373.1103.80.9.1.11ChannelSpacingread-createcurrent
tdmSettingsTable
OBJECT-TYPE
Table with tdm settings entries.
1.3.6.1.4.1.3373.1103.80.10not-accessiblecurrent
tdmSettingsEntry
OBJECT-TYPE
An entry containing tdm parameters for a particular link.
1.3.6.1.4.1.3373.1103.80.10.1not-accessiblecurrent
tdmPolIndex
OBJECT-TYPE
Polarization index.
1.3.6.1.4.1.3373.1103.80.10.1.1Integer32read-onlycurrent
tdmE1Channel
OBJECT-TYPE
Number of E1 channels. This object is used to define the capacity of E1 tributaries assigned to a given radio link. The capacity is changed in steps of E1 (2Mbit/s).
1.3.6.1.4.1.3373.1103.80.10.1.2Integer32read-writecurrent
tdmE1Framer
OBJECT-TYPE
This object is used to attach the framer to a given E1.
1.3.6.1.4.1.3373.1103.80.10.1.3INTEGER {disable(1), enable(2)}read-writecurrent
radioCapabilitiesTable
OBJECT-TYPE
Table with RadioCapabilities entries: there is an entry for each radioTable rows.
1.3.6.1.4.1.3373.1103.80.11not-accessiblecurrent
radioCapabilitiesEntry
OBJECT-TYPE
RadioCapabilities entry.
1.3.6.1.4.1.3373.1103.80.11.1not-accessiblecurrent
radioCapabilitiesCapability
OBJECT-TYPE
Bit map to describe the radio features.
1.3.6.1.4.1.3373.1103.80.11.1.1RadioCapabilityread-onlycurrent
radioCapabilitiesTxMinFrequency
OBJECT-TYPE
Minimum of available channel frequency in KHz.
1.3.6.1.4.1.3373.1103.80.11.1.2Integer32read-onlycurrent
radioCapabilitiesTxMaxFrequency
OBJECT-TYPE
Maximum of available channel frequency in KHz.
1.3.6.1.4.1.3373.1103.80.11.1.3Integer32read-onlycurrent
radioCapabilitiesStepFrequency
OBJECT-TYPE
Minimum frequency step in KHz.
1.3.6.1.4.1.3373.1103.80.11.1.4Integer32read-onlycurrent
radioCapabilitiesMinPtxNominalValue
OBJECT-TYPE
Minimum nominal Ptx in dBm.
1.3.6.1.4.1.3373.1103.80.11.1.5Integer32read-onlycurrent
radioCapabilitiesMaxPtxNominalValue
OBJECT-TYPE
Maximum nominal Ptx in dBm.
1.3.6.1.4.1.3373.1103.80.11.1.6Integer32read-onlycurrent
radioCapabilitiesExtendedMinPwr
OBJECT-TYPE
Minimum extended Ptx power for fade margin.
1.3.6.1.4.1.3373.1103.80.11.1.7Integer32read-onlycurrent
radioStatusTable
OBJECT-TYPE
Table with RadioStatus records: one record for 1+0 configuration and two record for 1+1 configuration.
1.3.6.1.4.1.3373.1103.80.12not-accessiblecurrent
radioStatusEntry
OBJECT-TYPE
RadioStatus record.
1.3.6.1.4.1.3373.1103.80.12.1not-accessiblecurrent
radioCurrentDuplexFrequency
OBJECT-TYPE
Spacing between transmitted and received frequency in KHz.
1.3.6.1.4.1.3373.1103.80.12.1.1Integer32read-onlycurrent
radioTxChannelSpacing
OBJECT-TYPE
Half of transmitted signal channel spacing in KHz.
1.3.6.1.4.1.3373.1103.80.12.1.2Integer32read-onlycurrent
radioPrx
OBJECT-TYPE
Received power level (dBm).
1.3.6.1.4.1.3373.1103.80.12.1.3Integer32read-onlycurrent
radioPtx
OBJECT-TYPE
Transmitted power level (dBm).
1.3.6.1.4.1.3373.1103.80.12.1.4Integer32read-onlycurrent
radioNormalizedMse
OBJECT-TYPE
Normalized MSE (Mean Squared Error) is an indicator of the Signal to Noise (S/N) ratio. It's in 0.1 dB steps
1.3.6.1.4.1.3373.1103.80.12.1.5Integer32read-onlycurrent
radioRxActiveStatus
OBJECT-TYPE
Receiver Active status with associated Severity In 1+1 Hot Standby radio system, only one RX is active. RXs are active in other configurations of the radio system.
1.3.6.1.4.1.3373.1103.80.12.1.6INTEGER {cleared(1), active(2)}read-onlycurrent
radioTxActiveStatus
OBJECT-TYPE
Transmitter Active status with associated Severity. In 1+1 Hot Standby radio system, only one TX is active. TXs are active in other configurations of the radio system.
1.3.6.1.4.1.3373.1103.80.12.1.7INTEGER {cleared(1), active(2)}read-onlycurrent
radioCableOpenAlarm
OBJECT-TYPE
Cable connnecting ODU is open: alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.8AlarmStatusread-onlycurrent
radioCableShortAlarm
OBJECT-TYPE
Cable connnecting ODU is in short-circuit: alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.9AlarmStatusread-onlycurrent
radioInvalidFrequencyAlarm
OBJECT-TYPE
Invalid frequency alarm with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.10AlarmStatusread-onlycurrent
radioBaseBandRxAlarm
OBJECT-TYPE
Base Band Rx alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.11AlarmStatusread-onlycurrent
radioModulatorFailAlarm
OBJECT-TYPE
Modulator Fail Alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.12AlarmStatusread-onlycurrent
radioDemodulatorFailAlarm
OBJECT-TYPE
Demodulator Fail Alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.13AlarmStatusread-onlycurrent
radioRxPowerLowAlarm
OBJECT-TYPE
Receiver power low alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.14AlarmStatusread-onlycurrent
radioTxPowerLowAlarm
OBJECT-TYPE
Transmitter power low alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.15AlarmStatusread-onlycurrent
radioRemDemodulatorFailAlarm
OBJECT-TYPE
Remote Demodulator Fail Alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.16AlarmStatusread-onlycurrent
radioVcoFailAlarm
OBJECT-TYPE
RT VCO fail alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.17AlarmStatusread-onlycurrent
radioRxIFAgcAlarm
OBJECT-TYPE
RT Rx IF AGC fail alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.18AlarmStatusread-onlycurrent
radioTxIFAgcAlarm
OBJECT-TYPE
RT Tx IF AGC fail alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.19AlarmStatusread-onlycurrent
radioIduOduCommunicationAlarm
OBJECT-TYPE
Communication from IDU towards ODU is down
1.3.6.1.4.1.3373.1103.80.12.1.20AlarmStatusread-onlycurrent
radioOduIduCommunicationAlarm
OBJECT-TYPE
Communication from ODU towards IDU is down
1.3.6.1.4.1.3373.1103.80.12.1.21AlarmStatusread-onlycurrent
radioLocalOduAlarmSynthesis
OBJECT-TYPE
Local ODU alarm synthesis with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.22AlarmStatusread-onlycurrent
radioRemoteOduAlarmSynthesis
OBJECT-TYPE
Local ODU alarm synthesis alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.23AlarmStatusread-onlycurrent
radioConfigMismatchAlarm
OBJECT-TYPE
Config Mismatch alarm status with associated severity and related map.
1.3.6.1.4.1.3373.1103.80.12.1.24AlarmStatusread-onlycurrent
radioConfigAlarmReason
OBJECT-TYPE
Bit map to describe the Config Mismatch Alarm
1.3.6.1.4.1.3373.1103.80.12.1.25ConfigMismatchReasonread-onlycurrent
radioRxQualityLowAlarm
OBJECT-TYPE
High BER Alarm status with associated severity.
1.3.6.1.4.1.3373.1103.80.12.1.26AlarmStatusread-onlycurrent
radioRxQualityWarningAlarm
OBJECT-TYPE
The RX signal is close to cause errors on payload.
1.3.6.1.4.1.3373.1103.80.12.1.27AlarmStatusread-onlycurrent
radioXpd
OBJECT-TYPE
Cross-Polarization Discrimination, in tenths of dB, is the difference between the received signal power of the co-polarized main beam, and it componemt received on the cross-polarized signal. This object shows an extimated value of the XPD performed by the cross-polarization interference canceller (XPIC). This means that the measure is reliable if: - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), or radio2p2XpicFD(6)) - Alarm radioDemodulatorFailAlarm is cleared. - XPD is not too high, since without cross-polar interference the canceller is not able to works well. Basically, in this condition, the extimated XPD is greater than the real one.
1.3.6.1.4.1.3373.1103.80.12.1.28Integer32read-onlycurrent
radioMaintTable
OBJECT-TYPE
Table with Command for maintenance of radio branch. Objects in this table is not persistent. An Instance of this table is created on creation of radioBranchEntry
1.3.6.1.4.1.3373.1103.80.13not-accessiblecurrent
radioMaintEntry
OBJECT-TYPE
Radio branch Maintenance record.
1.3.6.1.4.1.3373.1103.80.13.1not-accessiblecurrent
radioTxStatus
OBJECT-TYPE
Transmitter status control. The value transmitterOff(1) is related to a manual operation. The value permanentOff(3) is persistent across restart.
1.3.6.1.4.1.3373.1103.80.13.1.1INTEGER {transmitterOff(1), transmitterOn(2), permanentOff(3)}read-writecurrent
radioCarrierOnly
OBJECT-TYPE
Carrier only transmission control.
1.3.6.1.4.1.3373.1103.80.13.1.2INTEGER {carrierOnlyOff(1), carrierOnlyOn(2)}read-writecurrent
radioLoop
OBJECT-TYPE
Enables/disables the Radio Branch loops.
1.3.6.1.4.1.3373.1103.80.13.1.3INTEGER {loopOff(1), rfLoop(2), iqLoop(3), baseBandLoop(4), rfLoopAtFixedMod(6), baseBandLoopEthSquelch(7), rfLoopAtFixedModEthSquelch(8), iqloopEthSquelch(9)}read-writecurrent
radioRFLoopTestResult
OBJECT-TYPE
Radio branch RT loop test result.
1.3.6.1.4.1.3373.1103.80.13.1.4INTEGER {testNone(0), testRunning(1), testNotPossible(2), testPassed(3), testFail(4), testInterrupted(5)}read-onlycurrent
radioRFLoopTestPercTime
OBJECT-TYPE
Radio branch RT loop test time percentage
1.3.6.1.4.1.3373.1103.80.13.1.5INTEGER (0..100)read-onlycurrent
radioRtPsuOff
OBJECT-TYPE
It switches on/off the Rt power supply
1.3.6.1.4.1.3373.1103.80.13.1.6INTEGER {rtPsuOff(1), rtPsuOn(2)}read-writecurrent
radioLom
OBJECT-TYPE
It is used to enable the IP packet forwarding towards Radio.
1.3.6.1.4.1.3373.1103.80.13.1.7INTEGER {disable(1), enable(2)}read-writecurrent
radioXpic
OBJECT-TYPE
Enable of the cross polarization interference cancellation of this radio. The value disable is tied to a manual operation (ManOpRecord). This object is applicable only if thiis radio belongs to a 2+0 XPIC or 2+2 XPIC link.
1.3.6.1.4.1.3373.1103.80.13.1.8INTEGER {disable(1), enable(2)}read-writecurrent
radioFrequencyTable
OBJECT-TYPE
Availables channels for selected channel spacing and modulation (see leaf radioFreqTableSelection).
1.3.6.1.4.1.3373.1103.80.14not-accessiblecurrent
radioFreqTabEntry
OBJECT-TYPE
RadioFreqTab record.
1.3.6.1.4.1.3373.1103.80.14.1not-accessiblecurrent
radioFreqChannelId
OBJECT-TYPE
Index of the table
1.3.6.1.4.1.3373.1103.80.14.1.1Integer32read-onlycurrent
radioFreqChannelNum
OBJECT-TYPE
Available channel number.
1.3.6.1.4.1.3373.1103.80.14.1.2Integer32read-onlycurrent
radioFreqValue
OBJECT-TYPE
Frequency related to radioFreqChannelNum.
1.3.6.1.4.1.3373.1103.80.14.1.3Integer32read-onlycurrent
radioDuplexFrequencyTable
OBJECT-TYPE
Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency.
1.3.6.1.4.1.3373.1103.80.15not-accessiblecurrent
radioDuplexFreqEntry
OBJECT-TYPE
Duplex Frequency entry. There is an entry for each available duplex frequency.
1.3.6.1.4.1.3373.1103.80.15.1not-accessiblecurrent
radioDuplexFreqId
OBJECT-TYPE
Index of the table.
1.3.6.1.4.1.3373.1103.80.15.1.1Integer32read-onlycurrent
radioDuplexFreqValue
OBJECT-TYPE
Duplex frequency in KHz.
1.3.6.1.4.1.3373.1103.80.15.1.2Integer32read-onlycurrent
radioModulationTable
OBJECT-TYPE
List of modulations related to channel spacing.
1.3.6.1.4.1.3373.1103.80.16not-accessiblecurrent
radioModulationEntry
OBJECT-TYPE
radioModulation record.
1.3.6.1.4.1.3373.1103.80.16.1not-accessiblecurrent
radioChannelSpacing
OBJECT-TYPE
This object identifies the channel spacing.
1.3.6.1.4.1.3373.1103.80.16.1.1ChannelSpacingread-onlycurrent
radioModulationMap
OBJECT-TYPE
List of modulations in the radioChanSpacing
1.3.6.1.4.1.3373.1103.80.16.1.2ModulationMapread-onlycurrent
radioRefModulationMap
OBJECT-TYPE
List of modulations that can be selected as reference in the radioChanSpacingId
1.3.6.1.4.1.3373.1103.80.16.1.3ModulationMapread-onlycurrent
linkStatusTable
OBJECT-TYPE
Table with LinkStatusEntry.
1.3.6.1.4.1.3373.1103.80.17not-accessiblecurrent
linkStatusEntry
OBJECT-TYPE
Link status entry
1.3.6.1.4.1.3373.1103.80.17.1not-accessiblecurrent
linkPolIndex
OBJECT-TYPE
This object identifies the radio polarization. In XPIC radio link identifies one of the polarizations.
1.3.6.1.4.1.3373.1103.80.17.1.1INTEGER (1..2)read-onlycurrent
linkAcmRxProfile
OBJECT-TYPE
This object reports the ACM profile number in use in the radio Rx. It is the linkAcmProfileId of linkAcmTable. Label is linkAcmProfileLabel from linkAcmTable
1.3.6.1.4.1.3373.1103.80.17.1.2Integer32read-onlycurrent
linkAcmTxProfile
OBJECT-TYPE
This object reports the ACM profile number in use in the radio Tx. It is the linkAcmProfileId of linkAcmTable. Label is linkAcmProfileLabel from linkAcmTable
1.3.6.1.4.1.3373.1103.80.17.1.3Integer32read-onlycurrent
linkAcmRxProfileLabel
OBJECT-TYPE
ASCII string used to describe current acm rx profile
1.3.6.1.4.1.3373.1103.80.17.1.4DisplayString (SIZE(0..32))read-onlycurrent
linkAcmTxProfileLabel
OBJECT-TYPE
ASCII string used to describe current acm tx profile
1.3.6.1.4.1.3373.1103.80.17.1.5DisplayString (SIZE(0..32))read-onlycurrent
linkAcmRxModulation
OBJECT-TYPE
This object is the type of modulation of the Rx profile in use.
1.3.6.1.4.1.3373.1103.80.17.1.6BitsPerSymbolread-onlycurrent
linkAcmTxModulation
OBJECT-TYPE
This object is the type of modulation of the Tx profile in use.
1.3.6.1.4.1.3373.1103.80.17.1.7BitsPerSymbolread-onlycurrent
linkAcmRxCode
OBJECT-TYPE
This object is the type of codificator of the Rx profile in use.
1.3.6.1.4.1.3373.1103.80.17.1.8INTEGER {unknown(0), normal(1), strong(2)}read-onlycurrent
linkAcmTxCode
OBJECT-TYPE
This object is the type of codificator of the Tx profile in use.
1.3.6.1.4.1.3373.1103.80.17.1.9INTEGER {unknown(0), normal(1), strong(2)}read-onlycurrent
linkTxETHCapacity
OBJECT-TYPE
This object reports (in Kbits/sec) the transmitted payload capacity used by the Ethernet
1.3.6.1.4.1.3373.1103.80.17.1.10Integer32read-onlycurrent
linkRxETHCapacity
OBJECT-TYPE
This object reports (in Kbits/sec) the received payload capacity used by the Ethernet
1.3.6.1.4.1.3373.1103.80.17.1.11Integer32read-onlycurrent
linkTxTDMCapacity
OBJECT-TYPE
This object reports the capacity in kbit/sec reserved to TDM tributaries in tx ACM profile.
1.3.6.1.4.1.3373.1103.80.17.1.12Integer32read-onlycurrent
linkRxTDMCapacity
OBJECT-TYPE
This object reports the capacity in kbit/sec reserved to TDM tributaries in rx ACM profile.
1.3.6.1.4.1.3373.1103.80.17.1.13Integer32read-onlycurrent
linkRescueModulation
OBJECT-TYPE
This object is the modulation used when the remote terminal is unreachable, ie traffic on radio link is down.
1.3.6.1.4.1.3373.1103.80.17.1.14BitsPerSymbolread-onlycurrent
linkReducedCapacityAlarm
OBJECT-TYPE
The equipment works in reduced capacity
1.3.6.1.4.1.3373.1103.80.17.1.15AlarmStatusread-onlycurrent
linkLinkTelemetryFailAlarm
OBJECT-TYPE
Fail of link telemetry communication channel with associated Severity
1.3.6.1.4.1.3373.1103.80.17.1.16AlarmStatusread-onlycurrent
linkIdMismatchAlarm
OBJECT-TYPE
Link Identification Alarm with associated Severity
1.3.6.1.4.1.3373.1103.80.17.1.17AlarmStatusread-onlycurrent
linkRadioEocAlarm
OBJECT-TYPE
Fail of Radio Eoc link communication channel with associated Severity
1.3.6.1.4.1.3373.1103.80.17.1.18AlarmStatusread-onlycurrent
linkSetupMismatchAlarm
OBJECT-TYPE
The local setup doesn't match the setup of remote terminal
1.3.6.1.4.1.3373.1103.80.17.1.19AlarmStatusread-onlycurrent
linkRescueSetupAlarm
OBJECT-TYPE
The equipment is using the setup relative to the rescue modulation
1.3.6.1.4.1.3373.1103.80.17.1.20AlarmStatusread-onlycurrent
linkXpicProcedureBlockAlarm
OBJECT-TYPE
Only for XPIC equipment configurations. Equipment Controller XPIC procedure Alarm control with associated Severity
1.3.6.1.4.1.3373.1103.80.17.1.21AlarmStatusread-onlycurrent
linkXpicRemTxOffAlarm
OBJECT-TYPE
Only for XPIC equipment configurations. Remote TX OFF command with associated Severity
1.3.6.1.4.1.3373.1103.80.17.1.22AlarmStatusread-onlycurrent
linkRemoteIduAlarmSynthesis
OBJECT-TYPE
Synthesis of the remote IDU alarms
1.3.6.1.4.1.3373.1103.80.17.1.23AlarmStatusread-onlycurrent
linkNotMatchingRadiosAlarm
OBJECT-TYPE
Radios of the link does not have matched parameters.
1.3.6.1.4.1.3373.1103.80.17.1.24AlarmStatusread-onlycurrent
linkConfigurationInProgress
OBJECT-TYPE
The link is being configured and the table linkSettingsTable is not available for modifying parameters.
1.3.6.1.4.1.3373.1103.80.17.1.25INTEGER {cleared(1), active(2)}read-onlycurrent
linkXpd
OBJECT-TYPE
Cross-Polarization Discrimination, in tenths of dB, is the difference between the received signal power of the co-polarized main beam, and it componemt received on the cross-polarized signal. This object shows an extimated value of the XPD performed by the cross-polarization interference canceller (XPIC). This means that the measure is reliable if: - XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5), or radio2p2XpicFD(6)) - Alarm radioDemodulatorFailAlarm is cleared. - XPD is not too high, since without cross-polar interference the canceller is not able to works well. Basically, in this condition, the extimated XPD is greater than the real one.
1.3.6.1.4.1.3373.1103.80.17.1.26Integer32read-onlydeprecated
linkTfcTable
OBJECT-TYPE
Transmitter Fail Check feature. In 1+1 HS configuration, the radio terminal that doesn't receive signals on both receivers, requests the remote transmitter switch. This table was deprecated and replaced by linkTfcV2Table. It is a view of the rows of the linkTfcV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers.
1.3.6.1.4.1.3373.1103.80.18not-accessibledeprecated
linkTfcEntry
OBJECT-TYPE
Radio link TFC entry.
1.3.6.1.4.1.3373.1103.80.18.1not-accessibledeprecated
linkTfcAction
OBJECT-TYPE
reset: to clear the forced switch generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.18.1.1INTEGER {notActive(0), reset(1)}read-createdeprecated
linkTfcControl
OBJECT-TYPE
It enables the Tx switch from remote equipment (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.18.1.2INTEGER {disable(1), enable(2)}read-createdeprecated
linkTfcWatchWindow
OBJECT-TYPE
Watch Window (in seconds) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.18.1.3INTEGER (1..300)read-createdeprecated
linkTfcAlarmThreshold
OBJECT-TYPE
Alarm Threshold (number of seconds with both remote RX in fail) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.18.1.4INTEGER (1..60)read-createdeprecated
linkTfcAlarm
OBJECT-TYPE
Transmission switch alarm generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.18.1.5AlarmStatusread-onlydeprecated
linkTfcRowStatus
OBJECT-TYPE
Status of this conceptual row in linkTfcTable.
1.3.6.1.4.1.3373.1103.80.18.1.6RowStatusread-createdeprecated
linkMaintTable
OBJECT-TYPE
Table with commands for maintenance of radio link. Objects in this table is not persistent. An Instance of this table is created on creation of linkStatusEntry
1.3.6.1.4.1.3373.1103.80.19not-accessiblecurrent
linkMaintEntry
OBJECT-TYPE
Radio link maintenance entry.
1.3.6.1.4.1.3373.1103.80.19.1not-accessiblecurrent
linkBerStart
OBJECT-TYPE
Stop, Start (resetting errors and counters) the pattern. This item is linked to a manual operation (ManOpRecord) instance.
1.3.6.1.4.1.3373.1103.80.19.1.1INTEGER {restart(1), stop(2)}read-writecurrent
linkBaseBandLom
OBJECT-TYPE
It is used to enable the IP packet forwarding towards modems. This item is linked to a manual operation (ManOpRecord) instance.
1.3.6.1.4.1.3373.1103.80.19.1.2INTEGER {disable(1), enable(2)}read-writecurrent
linkFadeMarginMeasure
OBJECT-TYPE
Set by manager to start/stop fade margin measure. This item is linked to a manual operation (ManOpRecord) instance. This object is deprecated and replaced by fadeMarginMeasure.
1.3.6.1.4.1.3373.1103.80.19.1.3INTEGER {disable(1), enable(2)}read-writedeprecated
linkXpicControlProcedureReset
OBJECT-TYPE
Set by manager to reset the XPIC control procedure after a blocking action.
1.3.6.1.4.1.3373.1103.80.19.1.4INTEGER {notActive(0), reset(1)}read-writecurrent
linkBerTable
OBJECT-TYPE
Table with Command to estimate BER of radio equipment. Every objects in this table is not persistent. An Instance of this table is created on creation of linkStatusEntry
1.3.6.1.4.1.3373.1103.80.20not-accessiblecurrent
linkBerEntry
OBJECT-TYPE
Radio equipment BER estimate record.
1.3.6.1.4.1.3373.1103.80.20.1not-accessiblecurrent
linkBerErrorCounterH
OBJECT-TYPE
High 32 bit part of the 64 bit error counter. Bit 32-63.
1.3.6.1.4.1.3373.1103.80.20.1.1Counter32read-onlycurrent
linkBerErrorCounterL
OBJECT-TYPE
Low 32 bit part of the 64 bit error counter. Bit 0-31.
1.3.6.1.4.1.3373.1103.80.20.1.2Counter32read-onlycurrent
linkBerDataCounterH
OBJECT-TYPE
High 32 bit part of the 64 bit data counter. Bit 32-63.
1.3.6.1.4.1.3373.1103.80.20.1.3Counter32read-onlycurrent
linkBerDataCounterL
OBJECT-TYPE
Low 32 bit part of the 64 bit data counter. Bit 0-31.
1.3.6.1.4.1.3373.1103.80.20.1.4Counter32read-onlycurrent
linkBerSyncLossAlarm
OBJECT-TYPE
BER sync loss alarm.
1.3.6.1.4.1.3373.1103.80.20.1.5AlarmStatusread-onlycurrent
linkBerSyncLossAlarmCounter
OBJECT-TYPE
BER sync loss events counter.
1.3.6.1.4.1.3373.1103.80.20.1.6Integer32read-onlycurrent
linkBerElapsedTime
OBJECT-TYPE
BER measure elapsed time.
1.3.6.1.4.1.3373.1103.80.20.1.7Integer32read-onlycurrent
linkAcmTable
OBJECT-TYPE
Table with link records.
1.3.6.1.4.1.3373.1103.80.21not-accessiblecurrent
linkAcmEntry
OBJECT-TYPE
ACM entries.
1.3.6.1.4.1.3373.1103.80.21.1not-accessiblecurrent
linkAcmProfileId
OBJECT-TYPE
This object identifies the profile number for the radio selected by the object linkAcmId.
1.3.6.1.4.1.3373.1103.80.21.1.1Integer32read-onlycurrent
linkAcmProfileModulation
OBJECT-TYPE
This object is the modulation of the profile.
1.3.6.1.4.1.3373.1103.80.21.1.2BitsPerSymbolread-onlycurrent
linkAcmProfileCode
OBJECT-TYPE
This object is the type of codificator of the profile.
1.3.6.1.4.1.3373.1103.80.21.1.3INTEGER {normal(1), strong(2)}read-onlycurrent
linkAcmProfileCapacity
OBJECT-TYPE
This object is used to contain total capacity of profile (in kbits/sec).
1.3.6.1.4.1.3373.1103.80.21.1.4Integer32read-onlycurrent
linkAcmProfileLabel
OBJECT-TYPE
ASCII string used to assign a name to profile.
1.3.6.1.4.1.3373.1103.80.21.1.5DisplayString (SIZE(0..32))read-writecurrent
linkAcmProfileEnable
OBJECT-TYPE
The object is used to contain if the use of this profile is enabled or disabled
1.3.6.1.4.1.3373.1103.80.21.1.6INTEGER {disable(1), enable(2)}read-onlycurrent
linkAcmMaxTDMCapacity
OBJECT-TYPE
This object reports the maximum capacity that can be assigned to the TDM traffic. The capacity is specified in number of E1 (2Mbit/s). This object has been superseded by linkE1vsSTM1CapacityTable.
1.3.6.1.4.1.3373.1103.80.21.1.7Integer32read-onlydeprecated
linkAcmPowerScaling
OBJECT-TYPE
This object contains the difference (in eighth of dB) between the TX power at this profile modulation and the TX power at the reference modulation. The power scaling value is achieved from the table linkPtxProfileTable. This object is deprecated: see combinedRadioPowerScalingTable.
1.3.6.1.4.1.3373.1103.80.21.1.8Integer32read-onlydeprecated
linkAcmDownshiftThreshold
OBJECT-TYPE
The object is used to contain the downshift threshold in dB/10.
1.3.6.1.4.1.3373.1103.80.21.1.9Integer32read-onlycurrent
linkAcmUpshiftThreshold
OBJECT-TYPE
The object is used to contain the upshift threshold in dB/10.
1.3.6.1.4.1.3373.1103.80.21.1.10Integer32read-onlycurrent
linkAcmActiveProfile
OBJECT-TYPE
This object is used to contain the active status of this profile. The value of the object is related to linkAcmRxProfile and linkAcmTxProfile of the LinkStatusEntry.
1.3.6.1.4.1.3373.1103.80.21.1.11INTEGER {cleared(1), activeRx(2), activeTx(3), activeBoth(4)}read-onlycurrent
linkAcmTDMCapacity
OBJECT-TYPE
This object reports current TDM capacity (in kbits/sec) of the profile.
1.3.6.1.4.1.3373.1103.80.21.1.12Integer32read-onlycurrent
linkAcmETHCapacity
OBJECT-TYPE
This object reports current ETH capacity (in Kbits/sec) of the profile.
1.3.6.1.4.1.3373.1103.80.21.1.13Integer32read-onlycurrent
linkAcmAtpcRxPowerScaling
OBJECT-TYPE
This object contains the difference (in eighth of dB) between the ATPC RX level thresholds at this profile modulation and the ATPC RX level thresholds at the upper modulation. This object is deprecated: see combinedRadioPowerScalingTable.
1.3.6.1.4.1.3373.1103.80.21.1.14Integer32read-onlydeprecated
linkAcmPowerRange
OBJECT-TYPE
This object contains (in dB) the current value of ATPC range. This object is deprecated: see combinedRadioPowerScalingTable.
1.3.6.1.4.1.3373.1103.80.21.1.15Integer32read-onlydeprecated
linkProTable
OBJECT-TYPE
A list of protection link entries. This table was deprecated and replaced by linkProV2Table. It is a view of the rows of the linkProV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers
1.3.6.1.4.1.3373.1103.80.22not-accessibledeprecated
linkProEntry
OBJECT-TYPE
An entry containing management information applicable to a protected link.
1.3.6.1.4.1.3373.1103.80.22.1not-accessibledeprecated
linkProProtectionTxChIdx
OBJECT-TYPE
This object identifies the tx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set.
1.3.6.1.4.1.3373.1103.80.22.1.1Integer32read-createdeprecated
linkProProtectionRxChIdx
OBJECT-TYPE
This object identifies the rx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set.
1.3.6.1.4.1.3373.1103.80.22.1.2Integer32read-createdeprecated
linkProTxWtrTime
OBJECT-TYPE
It defines the Wait Time (in minutes) to Restore in transmission when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set.
1.3.6.1.4.1.3373.1103.80.22.1.3INTEGER (0..12)read-createdeprecated
linkProRxWtrTime
OBJECT-TYPE
It defines the Wait Time (in minutes) to Restore in reception when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set.
1.3.6.1.4.1.3373.1103.80.22.1.4INTEGER (0..12)read-createdeprecated
linkProTxSwitchedChIdx
OBJECT-TYPE
This object reports the index of tx channel switched to protection. This object is applicable only for N+1 protection schema.
1.3.6.1.4.1.3373.1103.80.22.1.5Integer32read-onlydeprecated
linkProRxSwitchedChIdx
OBJECT-TYPE
This object reports the index of rx channel switched to protection. This object is applicable only for N+1 protection schema.
1.3.6.1.4.1.3373.1103.80.22.1.6Integer32read-onlydeprecated
linkProTxRevertive
OBJECT-TYPE
It defines if tx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive.
1.3.6.1.4.1.3373.1103.80.22.1.7INTEGER {disable(1), enable(2)}read-createdeprecated
linkProRxRevertive
OBJECT-TYPE
It defines if rx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive.
1.3.6.1.4.1.3373.1103.80.22.1.8INTEGER {disable(1), enable(2)}read-createdeprecated
linkProExtraTraffic
OBJECT-TYPE
This object enables or disables the transfer of extra traffic on the protection channel in a N+1 link. This object must be set to disabled in case of architectures different for N+1.
1.3.6.1.4.1.3373.1103.80.22.1.9INTEGER {disable(1), enable(2)}read-createdeprecated
linkProRowStatus
OBJECT-TYPE
Status of this conceptual row in linkProTable.
1.3.6.1.4.1.3373.1103.80.22.1.10RowStatusread-createdeprecated
linkProMaintTable
OBJECT-TYPE
A list of maintenance commands for protected links. A row in this table is added on creation of a row in linkProTable. This table was deprecated and replaced by linkProMaintV2Table. It is a view of the rows of the linkProMaintV2Table with the same linkIndex and linkPolIndex equal to 1, in order to ensure compatibility with old SNMP managers
1.3.6.1.4.1.3373.1103.80.23not-accessibledeprecated
linkProMaintEntry
OBJECT-TYPE
An entry containing maintenance commands applicable to a protected link.
1.3.6.1.4.1.3373.1103.80.23.1not-accessibledeprecated
linkProMaintTxLockout
OBJECT-TYPE
Command to enable/disable tx lockout. This object is applicable only in case of N+1 protections.
1.3.6.1.4.1.3373.1103.80.23.1.1INTEGER {disable(1), enable(2)}read-writedeprecated
linkProMaintRxLockout
OBJECT-TYPE
Command to enable/disable rx lockout. This object is applicable only in case of N+1 protections.
1.3.6.1.4.1.3373.1103.80.23.1.2INTEGER {disable(1), enable(2)}read-writedeprecated
linkProMaintTxForced
OBJECT-TYPE
Command to force switch to a given transmission channel. Zero value means no switch.
1.3.6.1.4.1.3373.1103.80.23.1.3Integer32read-writedeprecated
linkProMaintRxForced
OBJECT-TYPE
Command to force switch to a given receiving channel. Zero value means no switch.
1.3.6.1.4.1.3373.1103.80.23.1.4Integer32read-writedeprecated
linkProMaintTxWtrReset
OBJECT-TYPE
Clear wait time to restore making the revertive path immediately available.
1.3.6.1.4.1.3373.1103.80.23.1.5INTEGER {notActive(1), on(2)}read-writedeprecated
linkProMaintRxWtrReset
OBJECT-TYPE
Clear wait time to restore making the revertive path immediately available.
1.3.6.1.4.1.3373.1103.80.23.1.6INTEGER {notActive(1), on(2)}read-writedeprecated
linkCapabilitiesTable
OBJECT-TYPE
Table with RadioCapabilities entries: there is an entry for each linkTable row. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the capabilities of each channel. As such, this table is declared deprecated and replaced by combinedRadioCapabilitiesTable.
1.3.6.1.4.1.3373.1103.80.24not-accessibledeprecated
linkCapabilitiesEntry
OBJECT-TYPE
LinkCapabilities entry.
1.3.6.1.4.1.3373.1103.80.24.1not-accessibledeprecated
linkCapabilitiesCapability
OBJECT-TYPE
Bit map to describe the radio features.
1.3.6.1.4.1.3373.1103.80.24.1.1RadioCapabilityread-onlydeprecated
linkCapabilitiesTxMinFrequency
OBJECT-TYPE
Minimum of available channel frequency in KHz.
1.3.6.1.4.1.3373.1103.80.24.1.2Integer32read-onlydeprecated
linkCapabilitiesTxMaxFrequency
OBJECT-TYPE
Maximum of available channel frequency in KHz.
1.3.6.1.4.1.3373.1103.80.24.1.3Integer32read-onlydeprecated
linkCapabilitiesStepFrequency
OBJECT-TYPE
Minimum frequency step in KHz.
1.3.6.1.4.1.3373.1103.80.24.1.4Integer32read-onlydeprecated
linkCapabilitiesMinPtxNominalValue
OBJECT-TYPE
Minimum nominal Ptx in dBm.
1.3.6.1.4.1.3373.1103.80.24.1.5Integer32read-onlydeprecated
linkCapabilitiesMaxPtxNominalValue
OBJECT-TYPE
Maximum nominal Ptx in dBm.
1.3.6.1.4.1.3373.1103.80.24.1.6Integer32read-onlydeprecated
linkCapabilitiesExtendedMinPwr
OBJECT-TYPE
Minimum extended Ptx power for fade margin.
1.3.6.1.4.1.3373.1103.80.24.1.7Integer32read-onlydeprecated
linkFrequencyTable
OBJECT-TYPE
Availables channels for selected channel spacing and modulation In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the allowable frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioFrequencyTable.
1.3.6.1.4.1.3373.1103.80.25not-accessibledeprecated
linkFreqTabEntry
OBJECT-TYPE
LinkFreqTab record.
1.3.6.1.4.1.3373.1103.80.25.1not-accessibledeprecated
linkFreqChannelId
OBJECT-TYPE
Index of the table
1.3.6.1.4.1.3373.1103.80.25.1.1Integer32read-onlydeprecated
linkFreqChannelNum
OBJECT-TYPE
Available channel number.
1.3.6.1.4.1.3373.1103.80.25.1.2Integer32read-onlydeprecated
linkFreqValue
OBJECT-TYPE
Frequency related to linkFreqChannelNum.
1.3.6.1.4.1.3373.1103.80.25.1.3Integer32read-onlydeprecated
linkDuplexFrequencyTable
OBJECT-TYPE
Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios. In 1+1 FD radio link, managers have to know the allowable duplex frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioDuplexFrequencyTable.
1.3.6.1.4.1.3373.1103.80.26not-accessibledeprecated
linkDuplexFreqEntry
OBJECT-TYPE
Duplex Frequency entry. For each available duplex frequency
1.3.6.1.4.1.3373.1103.80.26.1not-accessibledeprecated
linkDuplexFreqId
OBJECT-TYPE
Index of the table.
1.3.6.1.4.1.3373.1103.80.26.1.1Integer32read-onlydeprecated
linkDuplexFreqValue
OBJECT-TYPE
Duplex frequency in KHz.
1.3.6.1.4.1.3373.1103.80.26.1.2Integer32read-onlydeprecated
linkModulationTable
OBJECT-TYPE
List of modulation related to channel spacing. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios.
1.3.6.1.4.1.3373.1103.80.27not-accessiblecurrent
linkModulationEntry
OBJECT-TYPE
linkModulation record.
1.3.6.1.4.1.3373.1103.80.27.1not-accessiblecurrent
linkChannelSpacing
OBJECT-TYPE
This object identifies the channel spacing.
1.3.6.1.4.1.3373.1103.80.27.1.1ChannelSpacingread-onlycurrent
linkModulationMap
OBJECT-TYPE
List of modulation in the linkChanSpacing
1.3.6.1.4.1.3373.1103.80.27.1.2ModulationMapread-onlycurrent
linkRefModulationMap
OBJECT-TYPE
List of modulations that can be selected as reference in the linkChanSpacingId
1.3.6.1.4.1.3373.1103.80.27.1.3ModulationMapread-onlycurrent
combinedRadioCapabilitiesTable
OBJECT-TYPE
Table with RadioCapabilities entries: there is an entry for each radioSettingTable row. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios belonging to the link. In 1+1 FD radio link, managers have to know the allowable duplex frequencies of each channel. As such, this table is declared deprecated and replaced by combinedRadioCapabilitiesTable.
1.3.6.1.4.1.3373.1103.80.28not-accessiblecurrent
combinedRadioCapabilitiesEntry
OBJECT-TYPE
combinedRadioCapabilities entry.
1.3.6.1.4.1.3373.1103.80.28.1not-accessiblecurrent
combinedRadioCapabilitiesCapability
OBJECT-TYPE
Bit map to describe the radio features.
1.3.6.1.4.1.3373.1103.80.28.1.1RadioCapabilityread-onlycurrent
combinedRadioCapabilitiesTxMinFrequency
OBJECT-TYPE
Minimum of available channel frequency in KHz.
1.3.6.1.4.1.3373.1103.80.28.1.2Integer32read-onlycurrent
combinedRadioCapabilitiesTxMaxFrequency
OBJECT-TYPE
Maximum of available channel frequency in KHz.
1.3.6.1.4.1.3373.1103.80.28.1.3Integer32read-onlycurrent
combinedRadioCapabilitiesStepFrequency
OBJECT-TYPE
Minimum frequency step in KHz.
1.3.6.1.4.1.3373.1103.80.28.1.4Integer32read-onlycurrent
combinedRadioCapabilitiesMinPtxNominalValue
OBJECT-TYPE
Minimum nominal Ptx in dBm.
1.3.6.1.4.1.3373.1103.80.28.1.5Integer32read-onlycurrent
combinedRadioCapabilitiesMaxPtxNominalValue
OBJECT-TYPE
Maximum nominal Ptx in dBm.
1.3.6.1.4.1.3373.1103.80.28.1.6Integer32read-onlycurrent
combinedRadioCapabilitiesExtendedMinPwr
OBJECT-TYPE
Minimum extended Ptx power for fade margin.
1.3.6.1.4.1.3373.1103.80.28.1.7Integer32read-onlycurrent
combinedRadioFrequencyTable
OBJECT-TYPE
Availables channels for selected channel spacing and modulation In 1+1 HS and XPIC radio links, this table contains only values supported by both radios.
1.3.6.1.4.1.3373.1103.80.29not-accessiblecurrent
combinedRadioFreqTabEntry
OBJECT-TYPE
combinedRadioFreqTab record.
1.3.6.1.4.1.3373.1103.80.29.1not-accessiblecurrent
combinedRadioFreqChannelId
OBJECT-TYPE
Index of the table
1.3.6.1.4.1.3373.1103.80.29.1.1Integer32read-onlycurrent
combinedRadioFreqChannelNum
OBJECT-TYPE
Available channel number.
1.3.6.1.4.1.3373.1103.80.29.1.2Integer32read-onlycurrent
combinedRadioFreqValue
OBJECT-TYPE
Frequency related to combinedRadioFreqChannelNum.
1.3.6.1.4.1.3373.1103.80.29.1.3Integer32read-onlycurrent
combinedRadioDuplexFrequencyTable
OBJECT-TYPE
Table with available duplex frequencies. Duplex frequency is the absolute value of difference between RX and TX frequency. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios.
1.3.6.1.4.1.3373.1103.80.30not-accessiblecurrent
combinedRadioDuplexFreqEntry
OBJECT-TYPE
Duplex Frequency entry. There is an entry for each available duplex frequency.
1.3.6.1.4.1.3373.1103.80.30.1not-accessiblecurrent
combinedRadioDuplexFreqId
OBJECT-TYPE
Index of the table.
1.3.6.1.4.1.3373.1103.80.30.1.1Integer32read-onlycurrent
combinedRadioDuplexFreqValue
OBJECT-TYPE
Duplex frequency in KHz.
1.3.6.1.4.1.3373.1103.80.30.1.2Integer32read-onlycurrent
combinedRadioPowerScalingTable
OBJECT-TYPE
List of modulation related to channel spacing. In 1+1 HS and XPIC radio links, this table contains only values supported by both radios.
1.3.6.1.4.1.3373.1103.80.31not-accessiblecurrent
combinedRadioPowerScalingEntry
OBJECT-TYPE
radioPowerScaling record.
1.3.6.1.4.1.3373.1103.80.31.1not-accessiblecurrent
combinedRadioPowerScaling
OBJECT-TYPE
This object contains the difference (in eighth of dB) between the TX power at this profile modulation and the TX power at the reference modulation. The power scaling value is achieved from the table linkPtxProfileTable.
1.3.6.1.4.1.3373.1103.80.31.1.1Integer32read-onlycurrent
combinedRadioAtpcRxPowerScaling
OBJECT-TYPE
This object contains the difference (in eighth of dB) between the ATPC RX level thresholds at this profile modulation and the ATPC RX level thresholds at the upper modulation.
1.3.6.1.4.1.3373.1103.80.31.1.2Integer32read-onlycurrent
combinedRadioPowerRange
OBJECT-TYPE
This object contains (in dB) the current value of ATPC range.
1.3.6.1.4.1.3373.1103.80.31.1.3Integer32read-onlycurrent
stm1BulkMappingTable
OBJECT-TYPE
Table with entries containing stm-1 bulk transport parameters for a particular link. For each link are present as many rows as the STM-1 that the link can carry in bulk mode.
1.3.6.1.4.1.3373.1103.80.32not-accessiblecurrent
stm1BulkMappingEntry
OBJECT-TYPE
An row in stm1BulkSettingsTable.
1.3.6.1.4.1.3373.1103.80.32.1not-accessiblecurrent
stm1BulkPolIndex
OBJECT-TYPE
Polarization index.
1.3.6.1.4.1.3373.1103.80.32.1.1Integer32read-onlycurrent
stm1BulkChanIndex
OBJECT-TYPE
STM-1 channel index. The range of this object is from 1 to N, where N is the number of STM-1 that a link can carry in bulk mode.
1.3.6.1.4.1.3373.1103.80.32.1.2Integer32read-onlycurrent
stm1BulkChannel
OBJECT-TYPE
Index of the stm-1 in stm1Table. The SNMP agent will accept only index of a STM-1 present in stm1Table with stm1Structure set to opaque(4).
1.3.6.1.4.1.3373.1103.80.32.1.3Stm1IndexOrZeroread-writecurrent
linkE1vsSTM1CapacityTable
OBJECT-TYPE
Table with entries containing the E1 cpacity according to the tributaries STM-1 configured to be carried in bulk mode.
1.3.6.1.4.1.3373.1103.80.33not-accessiblecurrent
linkE1vsSTM1CapacityEntry
OBJECT-TYPE
An row in linkE1vsSTM1CapacityTable.
1.3.6.1.4.1.3373.1103.80.33.1not-accessiblecurrent
linkE1vsSTM1CapacityStm1
OBJECT-TYPE
Number of tributaries STM-1 configured to be transported in bulk mode.
1.3.6.1.4.1.3373.1103.80.33.1.1Integer32not-accessiblecurrent
linkE1vsSTM1CapacityE1
OBJECT-TYPE
Number of E1 that can be carried by this profile according to the the tributaries STM-1 carried in bulk mode.
1.3.6.1.4.1.3373.1103.80.33.1.2Integer32read-onlycurrent
linkTfcV2Table
OBJECT-TYPE
Transmitter Fail Check feature. In 1+1 HS configuration, the radio terminal that doesn't receive signals on both receivers, requests the remote transmitter switch.
1.3.6.1.4.1.3373.1103.80.34not-accessiblecurrent
linkTfcV2Entry
OBJECT-TYPE
Radio link TFC entry.
1.3.6.1.4.1.3373.1103.80.34.1not-accessiblecurrent
linkTfcV2Action
OBJECT-TYPE
reset: to clear the forced switch generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.34.1.1INTEGER {notActive(0), reset(1)}read-createcurrent
linkTfcV2Control
OBJECT-TYPE
It enables the Tx switch from remote equipment (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.34.1.2INTEGER {disable(1), enable(2)}read-createcurrent
linkTfcV2WatchWindow
OBJECT-TYPE
Watch Window (in seconds) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.34.1.3INTEGER (1..300)read-createcurrent
linkTfcV2AlarmThreshold
OBJECT-TYPE
Alarm Threshold (number of seconds with both remote RX in fail) related to Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.34.1.4INTEGER (1..60)read-createcurrent
linkTfcV2Alarm
OBJECT-TYPE
Transmission switch alarm generated by Trasmission Fail Check algorithm (only if 1+1 configuration and ISO system).
1.3.6.1.4.1.3373.1103.80.34.1.5AlarmStatusread-onlycurrent
linkTfcV2RowStatus
OBJECT-TYPE
Status of this conceptual row in linkTfcV2Table.
1.3.6.1.4.1.3373.1103.80.34.1.6RowStatusread-createcurrent
linkProV2Table
OBJECT-TYPE
A list of protection link entries.
1.3.6.1.4.1.3373.1103.80.35not-accessiblecurrent
linkProV2Entry
OBJECT-TYPE
An entry containing management information applicable to a protected link.
1.3.6.1.4.1.3373.1103.80.35.1not-accessiblecurrent
linkProV2ProtectionTxChIdx
OBJECT-TYPE
This object identifies the tx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set.
1.3.6.1.4.1.3373.1103.80.35.1.1Integer32read-createcurrent
linkProV2ProtectionRxChIdx
OBJECT-TYPE
This object identifies the rx protection channel of a protected link. This object is not applicable in case of not-revertive protection. For N+1 links a value different from zero must be set.
1.3.6.1.4.1.3373.1103.80.35.1.2Integer32read-createcurrent
linkProV2TxWtrTime
OBJECT-TYPE
It defines the Wait Time (in minutes) to Restore in transmission when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set.
1.3.6.1.4.1.3373.1103.80.35.1.3INTEGER (0..12)read-createcurrent
linkProV2RxWtrTime
OBJECT-TYPE
It defines the Wait Time (in minutes) to Restore in reception when revertive protection is enabled. Zero value means no switch. If switch is not supported or protection is not revertive, a value different from zero cannot be set.
1.3.6.1.4.1.3373.1103.80.35.1.4INTEGER (0..12)read-createcurrent
linkProV2TxSwitchedChIdx
OBJECT-TYPE
This object reports the index of tx channel switched to protection. This object is applicable only for N+1 protection schema.
1.3.6.1.4.1.3373.1103.80.35.1.5Integer32read-onlycurrent
linkProV2RxSwitchedChIdx
OBJECT-TYPE
This object reports the index of rx channel switched to protection. This object is applicable only for N+1 protection schema.
1.3.6.1.4.1.3373.1103.80.35.1.6Integer32read-onlycurrent
linkProV2TxRevertive
OBJECT-TYPE
It defines if tx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive.
1.3.6.1.4.1.3373.1103.80.35.1.7INTEGER {disable(1), enable(2)}read-createcurrent
linkProV2RxRevertive
OBJECT-TYPE
It defines if rx protection is revertive or not revertive. In case of N+1 protection, protection is always revertive.
1.3.6.1.4.1.3373.1103.80.35.1.8INTEGER {disable(1), enable(2)}read-createcurrent
linkProV2ExtraTraffic
OBJECT-TYPE
This object enables or disables the transfer of extra traffic on the protection channel in a N+1 link. This object must be set to disabled in case of architectures different for N+1.
1.3.6.1.4.1.3373.1103.80.35.1.9INTEGER {disable(1), enable(2)}read-createcurrent
linkProV2RowStatus
OBJECT-TYPE
Status of this conceptual row in linkProV2Table.
1.3.6.1.4.1.3373.1103.80.35.1.10RowStatusread-createcurrent
linkProMaintV2Table
OBJECT-TYPE
A list of maintenance commands for protected links. A row in this table is added on creation of a row in linkProV2Table.
1.3.6.1.4.1.3373.1103.80.36not-accessiblecurrent
linkProMaintV2Entry
OBJECT-TYPE
An entry containing maintenance commands applicable to a protected link.
1.3.6.1.4.1.3373.1103.80.36.1not-accessiblecurrent
linkProMaintV2TxLockout
OBJECT-TYPE
Command to enable/disable tx lockout. This object is applicable only in case of N+1 protections.
1.3.6.1.4.1.3373.1103.80.36.1.1INTEGER {disable(1), enable(2)}read-writecurrent
linkProMaintV2RxLockout
OBJECT-TYPE
Command to enable/disable rx lockout. This object is applicable only in case of N+1 protections.
1.3.6.1.4.1.3373.1103.80.36.1.2INTEGER {disable(1), enable(2)}read-writecurrent
linkProMaintV2TxForced
OBJECT-TYPE
Command to force switch to a given transmission channel. Zero value means no switch.
1.3.6.1.4.1.3373.1103.80.36.1.3Integer32read-writecurrent
linkProMaintV2RxForced
OBJECT-TYPE
Command to force switch to a given receiving channel. Zero value means no switch.
1.3.6.1.4.1.3373.1103.80.36.1.4Integer32read-writecurrent
linkProMaintV2TxWtrReset
OBJECT-TYPE
Clear wait time to restore making the revertive path immediately available.
1.3.6.1.4.1.3373.1103.80.36.1.5INTEGER {notActive(1), on(2)}read-writecurrent
linkProMaintV2RxWtrReset
OBJECT-TYPE
Clear wait time to restore making the revertive path immediately available.
1.3.6.1.4.1.3373.1103.80.36.1.6INTEGER {notActive(1), on(2)}read-writecurrent
sspTable
OBJECT-TYPE
A list of operative and administrative set of parameters. This table holds three row for every link (and its polarizations) configured in the NE: 1) administative parameters of local NE 2) operative parameters of local NE 3) administative parameters of remote NE
1.3.6.1.4.1.3373.1103.80.37not-accessiblecurrent
sspEntry
OBJECT-TYPE
An entry containing SSP relevant parameters.
1.3.6.1.4.1.3373.1103.80.37.1not-accessiblecurrent
sspParameterType
OBJECT-TYPE
This object identifies what parameters are for.
1.3.6.1.4.1.3373.1103.80.37.1.1INTEGER {localAdminStatus(1), localOperStatus(2), remoteAdminStatus(3)}not-accessiblecurrent
sspLinkBandwidth
OBJECT-TYPE
Link Bandwidth (channel spacing).
1.3.6.1.4.1.3373.1103.80.37.1.2INTEGER {sspBw3p5Mhz(0), sspBw7MHz(1), sspBw14MHz(2), sspBw28MHz(3), sspBw56MHz(4), sspBw10MHz(5), sspBw20MHz(6), sspBw30MHz(7), sspBw40MHz(8), sspBw50MHz(9), sspBw112Mhz(10), sspBw250Mhz(11), sspBw500Mhz(12), sspBw750Mhz(13), sspBw1Ghz(14), sspBw60MHz(15), sspBw80MHz(16)}read-onlycurrent
sspLinkModulation
OBJECT-TYPE
Link reference modulation.
1.3.6.1.4.1.3373.1103.80.37.1.3INTEGER {sspModBPSK(1), sspMod4QAM(2), sspMod8PSK(3), sspMod16QAM(4), sspMod32QAM(5), sspMod64QAM(6), sspMod128QAM(7), sspMod256QAM(8), sspMod512QAM(9), sspMod1024QAM(10), sspMod2048QAM(11), sspMod4096QAM(12)}read-onlycurrent
sspLinkAcmEngineEnable
OBJECT-TYPE
This object is used to enable/disable the ACM engine.
1.3.6.1.4.1.3373.1103.80.37.1.4INTEGER {disable(1), enable(2)}read-onlycurrent
sspLinkTxUpperProfile
OBJECT-TYPE
The object (and linkTxLowerProfile object) is used to restrict the TX profile range when ACM is enabled.
1.3.6.1.4.1.3373.1103.80.37.1.5INTEGERread-onlycurrent
sspLinkTxLowerProfile
OBJECT-TYPE
The object (and linkTxUpperProfile object) is used to restrict the TX profile range when ACM is enabled.
1.3.6.1.4.1.3373.1103.80.37.1.6INTEGERread-onlycurrent
sspLinkSynchSetupProtocolEnable
OBJECT-TYPE
Synchronization Setup Protocol (SSP) control.
1.3.6.1.4.1.3373.1103.80.37.1.7INTEGER {disable(1), enable(2)}read-onlycurrent
sspLinkProfilesSetSelection
OBJECT-TYPE
Selection of the working profile set between high gain (max robustness) profile set and high throughput (max capacity) profile set. The set of profiles high gain features a greater robustness against to the set of profiles high throughput. For radio systems that do not have more sets of profiles, this object becomes read only and its reading shows the only one set of profiles supported.
1.3.6.1.4.1.3373.1103.80.37.1.8INTEGER {highThroughput(1), highGain(2)}read-onlycurrent
sspTdmE1Channel
OBJECT-TYPE
Number of E1 channels. This object is used to define the capacity of E1 tributaries assigned to a given radio link. The capacity is changed in steps of E1 (2Mbit/s).
1.3.6.1.4.1.3373.1103.80.37.1.9Integer32read-onlycurrent
sspTdmStm1Channel
OBJECT-TYPE
Number of STM-1 channels transported in bulk mode.
1.3.6.1.4.1.3373.1103.80.37.1.10Integer32read-onlycurrent
radioLoopCapabilityTable
OBJECT-TYPE
This table shows which group a radio loop belongs to. Radios with the same group number (identifier) close loop simultaneously.
1.3.6.1.4.1.3373.1103.80.38not-accessiblecurrent
radioLoopCapabilityEntry
OBJECT-TYPE
An entry containing a group identifier for each radio loop type.
1.3.6.1.4.1.3373.1103.80.38.1not-accessiblecurrent
radioLoopRfGroup
OBJECT-TYPE
The group to which the radio RF loop belong to.
1.3.6.1.4.1.3373.1103.80.38.1.1Integer32read-onlycurrent
radioLoopIqGroup
OBJECT-TYPE
The group to which the radio IQ loop belong to.
1.3.6.1.4.1.3373.1103.80.38.1.2Integer32read-onlycurrent
radioLoopBaseBandGroup
OBJECT-TYPE
The group to which the radio base loop belong to.
1.3.6.1.4.1.3373.1103.80.38.1.3Integer32read-onlycurrent
radioRxBerThresholdTable
OBJECT-TYPE
This table shows the nominal and measured values of RX power at a bit error rate (BER) equal to 10e-6.
1.3.6.1.4.1.3373.1103.80.39not-accessiblecurrent
radioRxBerThresholdEntry
OBJECT-TYPE
An entry containing the RX power thresholds.
1.3.6.1.4.1.3373.1103.80.39.1not-accessiblecurrent
radioRxBerThresholdStatus
OBJECT-TYPE
This object shows whether the following objects are significant.
1.3.6.1.4.1.3373.1103.80.39.1.1INTEGER {nonValid(1), valid(2)}read-onlycurrent
radioNominalRxBerThreshold
OBJECT-TYPE
The nominal value of RX power @ BER equal to 10e-6
1.3.6.1.4.1.3373.1103.80.39.1.2Integer32read-onlycurrent
radioMeasuredRxBerThreshold
OBJECT-TYPE
The measured value of RX power @ BER equal to 10e-6.
1.3.6.1.4.1.3373.1103.80.39.1.3Integer32read-onlycurrent
radioRemDemodulatorFailAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioRemDemodulatorFailAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.50AlarmSeverityCoderead-writecurrent
radioRxActiveStatusTrapNotification
OBJECT-TYPE
Enable/disables (statusTrapEnable or statusTrapDisable) the trap generation on status change event for radioRxActivestatus
1.3.6.1.4.1.3373.1103.80.51INTEGER {trapDisable(1), trapEnable(2)}read-writecurrent
radioTxActiveStatusTrapNotification
OBJECT-TYPE
Define the severity associated to the radioTxActivestatus and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.52INTEGER {trapDisable(1), trapEnable(2)}read-writecurrent
radioCableOpenAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioCableOpen and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.53AlarmSeverityCoderead-writecurrent
radioCableShortAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioCableShort and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.54AlarmSeverityCoderead-writecurrent
radioInvalidFrequencyAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioInvalidFrequencyAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.55AlarmSeverityCoderead-writecurrent
radioBaseBandRxAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioBaseBandRxAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.56AlarmSeverityCoderead-writecurrent
radioModulatorFailAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioModulatorFailAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.57AlarmSeverityCoderead-writecurrent
radioDemodulatorFailAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioDemodulatorFailAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.58AlarmSeverityCoderead-writecurrent
radioRxPowerLowAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioRxPowerLowAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.59AlarmSeverityCoderead-writecurrent
radioTxPowerLowAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioTxPowerLowAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.60AlarmSeverityCoderead-writecurrent
radioVcoFailAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioVcoFailAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.61AlarmSeverityCoderead-writecurrent
radioRxIFAgcAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioRxIFAgcAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.62AlarmSeverityCoderead-writecurrent
radioTxIFAgcAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioTxIFAgcAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.63AlarmSeverityCoderead-writecurrent
radioIduOduCommunicationAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the radioIduOduCommunicationAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.64AlarmSeverityCoderead-writecurrent
radioOduIduCommunicationAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the radioOduIduCommunicationAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.65AlarmSeverityCoderead-writecurrent
radioLocalOduAlarmSynthesisSeverityCode
OBJECT-TYPE
Define the severity associated to the radioLocalOduAlarmSynthesis and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.66AlarmSeverityCoderead-writecurrent
radioRemoteOduAlarmSynthesisSeverityCode
OBJECT-TYPE
Define the severity associated to the radioRemoteOduAlarmSynthesis and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.67AlarmSeverityCoderead-writecurrent
radioConfigMismatchAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the radioConfigMismatchAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.68AlarmSeverityCoderead-writecurrent
radioPrxHysteresisValue
OBJECT-TYPE
Defines the delta value associated to the radioPrx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed.
1.3.6.1.4.1.3373.1103.80.69Integer32read-writecurrent
radioPtxHysteresisValue
OBJECT-TYPE
Defines the delta value associated to the radioPtx before having a new trap generation (radioPtxChange TRAP). The zero value is not allowed.
1.3.6.1.4.1.3373.1103.80.70Integer32read-writecurrent
radioPrxHysteresisValueTrapNotification
OBJECT-TYPE
Enables/disables the Rx change trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.71INTEGER {trapDisable(1), trapEnable(2)}read-writecurrent
radioPtxHysteresisValueTrapNotification
OBJECT-TYPE
Enables/disables the Tx change trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.72INTEGER {trapDisable(1), trapEnable(2)}read-writecurrent
radioRxQualityLowAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the radioRxQualityLowAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.73AlarmSeverityCoderead-writecurrent
radioRxQualityWarningAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the radioRxQualityWarningAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.74AlarmSeverityCoderead-writecurrent
linkReducedCapacityAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkReducedCapacityAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.75AlarmSeverityCoderead-writecurrent
linkLinkTelemetryFailAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkLinkTelemetryFailAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.76AlarmSeverityCoderead-writecurrent
linkIdMismatchAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkIdMismatchAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.77AlarmSeverityCoderead-writecurrent
linkRadioEocAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkRadioEocAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.78AlarmSeverityCoderead-writecurrent
linkSetupMismatchAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkSetupMismatchAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.79AlarmSeverityCoderead-writecurrent
linkRescueSetupAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkRescueSetupAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.80AlarmSeverityCoderead-writecurrent
linkXpicProcedureBlockAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkXpicProcedureBlockAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.81AlarmSeverityCoderead-writecurrent
linkXpicRemTxOffAlarmAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkXpicRemTxOffAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.82AlarmSeverityCoderead-writecurrent
linkLocalIduAlarmSynthesis
OBJECT-TYPE
Synthesis of the local IDU alarms
1.3.6.1.4.1.3373.1103.80.83AlarmStatusread-onlycurrent
linkLocalIduAlarmSynthesisSeverityCode
OBJECT-TYPE
Define the severity associated to the linkLocalIduAlarmSynthesis and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.84AlarmSeverityCoderead-writecurrent
linkRemoteIduAlarmSynthesisSeverityCode
OBJECT-TYPE
Define the severity associated to the linkLocalIduAlarmSynthesis and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.85AlarmSeverityCoderead-writecurrent
linkTfcAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkTfcV2Alarm (linkTfcAlarm) and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.86AlarmSeverityCoderead-writecurrent
linkBerSyncLossAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkBerSyncLossAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.87AlarmSeverityCoderead-writecurrent
linkNotMatchingRadiosAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the linkNotMatchingRadiosAlarm and enable/disable the trap generation on status change event.
1.3.6.1.4.1.3373.1103.80.88AlarmSeverityCoderead-writecurrent
channelSpacingSelection
OBJECT-TYPE
his object selects which channel spacings the radio link has to support: - etsi: Compliant with European Telecommunication Standards Institute - fcc: Compliant with Federal Communications Commission
1.3.6.1.4.1.3373.1103.80.89Bits {etsi(0), fcc(1)}read-writecurrent
fadeMarginMeasure
OBJECT-TYPE
Set by manager to start/stop fade margin measure. This item is linked to a manual operation (ManOpRecord) instance.
1.3.6.1.4.1.3373.1103.80.90INTEGER {disable(1), enable(2)}read-writecurrent
linkConfigurationInProgressTrapNotification
OBJECT-TYPE
Enable/disables (statusTrapEnable or statusTrapDisable) the trap generation on status change event for linkConfigurationInProgress
1.3.6.1.4.1.3373.1103.80.91INTEGER {trapDisable(1), trapEnable(2)}read-writecurrent

Notifications

NameOIDStatus
radioPrxChange
NOTIFICATION-TYPE
This event is generated when radioPrx is changed, in modulus, more than radioPtxHysteresisValue from last TRAP. The data passed with the event are: 1) equipIpSnmpAgentAddress - agent IP address 2) radioIndex - branch index 3) radioName - user assinged name 4) radioPrx - PRX value
1.3.6.1.4.1.3373.1103.0.8001current
radioPtxChange
NOTIFICATION-TYPE
This event is generated when radioPtx is changed, in modulus, more than radioPtxHysteresisValue from last TRAP. The data passed with the event are: 1) equipIpSnmpAgentAddress - agent IP address 2) radioIndex - branch index 3) radioName - user assigned name 4) radioPtx - PTX value
1.3.6.1.4.1.3373.1103.0.8002current