SIAE-PMTXPWR-MIB
- Registered at
- 1.3.6.1.4.1.3373.1103.13
- Last updated
- 2014-10-07 00:00
- Organization
- SIAE MICROELETTRONICA spa
- Revisions
- 2014-10-07 00:00, 2014-02-03 00:00, 2013-04-16 00:00
- Namespace
- siae
- Source file
SIAE-PMTXPWR-MIB- Digest
sha256:b5c408b64c005a488811b708101b88c7ca541e4480fc04f48867b6f1e97f9eaf
Description
Performance Monitoring on Transmitted (TX) RF Power.
Contact
SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: tbd@siaemic.com
Imports
| From | Symbols |
|---|---|
| SIAE-ALARM-MIB | AlarmSeverityCode, AlarmStatus |
| SIAE-TREE-MIB | siaeMib |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SIAE-ALARM-MIB SIAE-PMTXPWR-MIB SIAE-TREE-MIB SIAE-USER-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| pmTxPwrMibVersion OBJECT-TYPE Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01. | 1.3.6.1.4.1.3373.1103.13.1 | INTEGER | read-only | current |
| pmTxPwrCounterTable OBJECT-TYPE Table with PmTxPwr records: one record for 1+0 configuration and two record for 1+1 configuration. | 1.3.6.1.4.1.3373.1103.13.2 | not-accessible | current | |
| pmTxPwrCounterRecord OBJECT-TYPE PmTxPwrCounter record. | 1.3.6.1.4.1.3373.1103.13.2.1 | not-accessible | current | |
| pmTxPwrBranchId OBJECT-TYPE This object identifies the Radio Branch | 1.3.6.1.4.1.3373.1103.13.2.1.1 | Integer32 | read-only | current |
| pmTxPwrCounterBlockId OBJECT-TYPE This object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 19 15 minutes counters N. 16 (The oldest 15 minutes counters - 4 hours before). | 1.3.6.1.4.1.3373.1103.13.2.1.2 | Integer32 | read-only | current |
| pmTxPwrCounterBlockType OBJECT-TYPE The type of the counter block. | 1.3.6.1.4.1.3373.1103.13.2.1.3 | INTEGER {daily(1), fifteenMin(2)} | read-only | current |
| pmTxPwrCounterBlockStatus OBJECT-TYPE block counter status. | 1.3.6.1.4.1.3373.1103.13.2.1.4 | INTEGER {meaningless(1), meaningfull(2), incomplete(3), dummy(4), lost(5), restarted(6)} | read-only | current |
| pmTxPwrCounterTimeStamp OBJECT-TYPE The object is the time when the performance record is closed reported as the second number since 1-Gen-1970. | 1.3.6.1.4.1.3373.1103.13.2.1.5 | Unsigned32 | read-only | current |
| pmTxPwrTlts1Counter OBJECT-TYPE Number of seconds when the Transmitted power is greater than the threshold 1. | 1.3.6.1.4.1.3373.1103.13.2.1.6 | Counter32 | read-only | current |
| pmTxPwrTlts2Counter OBJECT-TYPE Number of seconds when the Transmitted power is greater than the threshold 2 | 1.3.6.1.4.1.3373.1103.13.2.1.7 | Counter32 | read-only | current |
| pmTxPwrTlts3Counter OBJECT-TYPE Number of seconds when the Transmitted power is greater than the threshold 3 | 1.3.6.1.4.1.3373.1103.13.2.1.8 | Counter32 | read-only | current |
| pmTxPwrTlts4Counter OBJECT-TYPE Number of seconds when the Transmitted power is greater than the threshold 4 | 1.3.6.1.4.1.3373.1103.13.2.1.9 | Counter32 | read-only | current |
| pmTxPwrTMMax OBJECT-TYPE Maximum Transmitted Power Level Tide Mark. | 1.3.6.1.4.1.3373.1103.13.2.1.10 | Integer32 | read-only | current |
| pmTxPwrTMMin OBJECT-TYPE Minimum Transmitted Power Level Tide Mark. | 1.3.6.1.4.1.3373.1103.13.2.1.11 | Integer32 | read-only | current |
| pmTxPwrAverageTxLevel OBJECT-TYPE Power Transmitted Level (Average value) | 1.3.6.1.4.1.3373.1103.13.2.1.12 | Integer32 | read-only | current |
| pmTxPwrTpClassTable OBJECT-TYPE Table with PmTxPwrTpClass records: one record for 1+0 configuration and two record for 1+1 configuration. | 1.3.6.1.4.1.3373.1103.13.3 | not-accessible | current | |
| pmTxPwrTpClassRecord OBJECT-TYPE PmTxPwrTpClass record. | 1.3.6.1.4.1.3373.1103.13.3.1 | not-accessible | current | |
| pmTxPwrTpClassBranchId OBJECT-TYPE This object identifies the Radio Branch | 1.3.6.1.4.1.3373.1103.13.3.1.1 | Integer32 | read-only | current |
| pmTxPwrTpClassStartStop OBJECT-TYPE This object is used to start and to stop the Perfomance Monitoring counter evaluation. | 1.3.6.1.4.1.3373.1103.13.3.1.2 | INTEGER {start(1), stop(2)} | read-create | current |
| pmTxPwrTpClassLabel OBJECT-TYPE ASCII string used to identify the Tp class: pmTxPwrTpClassBranchId = 1 label = Radio 1 pmTxPwrTpClassBranchId = 2 label = Radio 2. | 1.3.6.1.4.1.3373.1103.13.3.1.3 | DisplayString (SIZE(0..31)) | read-only | current |
| pmTxPwrTpClassTimeStamp OBJECT-TYPE The object is the time when the performance record is closed reported as the second number since 1/1/70. | 1.3.6.1.4.1.3373.1103.13.3.1.4 | Unsigned32 | read-only | current |
| pmTxPwrTpClass15MTlts1Alarm OBJECT-TYPE 15 minutes Tlts1 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.5 | AlarmStatus | read-only | current |
| pmTxPwrTpClass15MTlts2Alarm OBJECT-TYPE 15 minutes Tlts2 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.6 | AlarmStatus | read-only | current |
| pmTxPwrTpClass15MTlts3Alarm OBJECT-TYPE 15 minutes Tlts3 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.7 | AlarmStatus | read-only | current |
| pmTxPwrTpClass15MTlts4Alarm OBJECT-TYPE 15 minutes Tlts4 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.8 | AlarmStatus | read-only | current |
| pmTxPwrTpClass24HTlts1Alarm OBJECT-TYPE Daily Tlts1 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.9 | AlarmStatus | read-only | current |
| pmTxPwrTpClass24HTlts2Alarm OBJECT-TYPE Daily Tlts2 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.10 | AlarmStatus | read-only | current |
| pmTxPwrTpClass24HTlts3Alarm OBJECT-TYPE Daily Tlts3 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.11 | AlarmStatus | read-only | current |
| pmTxPwrTpClass24HTlts4Alarm OBJECT-TYPE Daily Tlts4 threshold cross alarm with associated severity. | 1.3.6.1.4.1.3373.1103.13.3.1.12 | AlarmStatus | read-only | current |
| pmTxPwrTpClassTlt1Threshold OBJECT-TYPE Received Power Level Threshold 1 (dBm value); range -100 to -20 | 1.3.6.1.4.1.3373.1103.13.3.1.13 | INTEGER (-100..-20) | read-create | current |
| pmTxPwrTpClassTlt2Threshold OBJECT-TYPE Received Power Level Threshold 2 (dBm value); range -100 to -20 | 1.3.6.1.4.1.3373.1103.13.3.1.14 | INTEGER (-100..-20) | read-create | current |
| pmTxPwrTpClassTlt3Threshold OBJECT-TYPE Received Power Level Threshold 3 (dBm value); range -100 to -20 | 1.3.6.1.4.1.3373.1103.13.3.1.15 | INTEGER (-100..-20) | read-create | current |
| pmTxPwrTpClassTlt4Threshold OBJECT-TYPE Received Power Level Threshold 4 (dBm value); range -100 to -20 | 1.3.6.1.4.1.3373.1103.13.3.1.16 | INTEGER (-100..-20) | read-create | current |
| pmTxPwrTpClass15MTlts1Threshold OBJECT-TYPE Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts1Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.17 | Integer32 | read-create | current |
| pmTxPwrTpClass15MTlts2Threshold OBJECT-TYPE Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts2Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.18 | Integer32 | read-create | current |
| pmTxPwrTpClass15MTlts3Threshold OBJECT-TYPE Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts3Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.19 | Integer32 | read-create | current |
| pmTxPwrTpClass15MTlts4Threshold OBJECT-TYPE Number of seconds within 15 minutes to set pmTxPwrTpClass15MTlts4Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.20 | Integer32 | read-create | current |
| pmTxPwrTpClass24HTlts1Threshold OBJECT-TYPE Number of seconds within a day to set pmTxPwrTpClass24HTlts1Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.21 | Integer32 | read-create | current |
| pmTxPwrTpClass24HTlts2Threshold OBJECT-TYPE Number of seconds within a day to set pmTxPwrTpClass24HTlts2Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.22 | Integer32 | read-create | current |
| pmTxPwrTpClass24HTlts3Threshold OBJECT-TYPE Number of seconds within a day to set pmTxPwrTpClass24HTlts3Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.23 | Integer32 | read-create | current |
| pmTxPwrTpClass24HTlts4Threshold OBJECT-TYPE Number of seconds within a day to set pmTxPwrTpClass24HTlts4Alarm (zero value disables the alarm). | 1.3.6.1.4.1.3373.1103.13.3.1.24 | Integer32 | read-create | current |
| pmTxPwrTpClassRowStatus OBJECT-TYPE Status of this row of pmTxPwrTpClass. | 1.3.6.1.4.1.3373.1103.13.3.1.25 | RowStatus | read-create | current |
| pmTxPwrTpMaintTable OBJECT-TYPE Table with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmTxPwrTpClassTable | 1.3.6.1.4.1.3373.1103.13.4 | not-accessible | current | |
| pmTxPwrTpMaintRecord OBJECT-TYPE PmG828 Termination Point Maintenance record. | 1.3.6.1.4.1.3373.1103.13.4.1 | not-accessible | current | |
| pmTxPwrTpMaintCounterClear OBJECT-TYPE This object is used to clear the Perfomance Monitoring counters. | 1.3.6.1.4.1.3373.1103.13.4.1.1 | INTEGER {notActive(0), clear(1)} | read-write | current |
| pmTxPwrTpMaintAlarmClear OBJECT-TYPE This object is used to clear the Perfomance Monitoring threshold cross alarms. | 1.3.6.1.4.1.3373.1103.13.4.1.2 | INTEGER {notActive(0), clear(1)} | read-write | current |
| pmTxPwrTpClass15MTltsAlarmSeverityCode OBJECT-TYPE Define the severity associated to the pmTxPwrTpClass15MTltsAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.13.5 | AlarmSeverityCode | read-write | current |
| pmTxPwrTpClass24HTltsAlarmSeverityCode OBJECT-TYPE Define the severity associated to the pmTxPwrTpClass24HTltsAlarm and enables/disables the trap generation on status change event. | 1.3.6.1.4.1.3373.1103.13.6 | AlarmSeverityCode | read-write | current |