MIBs Depot

SIAE-PMG828-MIB

Registered at
1.3.6.1.4.1.3373.1103.11
Last updated
2014-10-07 00:00
Organization
SIAE MICROELETTRONICA spa
Revisions
2014-10-07 00:00, 2014-02-03 00:00, 2013-04-16 00:00
Namespace
siae
Source file
SIAE-PMG828-MIB
Digest
sha256:35e364db742d5ee9418b026c68aff7f7e3c585f61a8dc3e5e2bfe33be28147a6

Description

Perforfamce Monitoring according to ITU-T G.829 for Radio Link and E1 Tributaries

Contact

SIAE MICROELETTONICA s.p.a. Via Michelangelo Buonarroti, 21 20093 - Cologno Monzese Milano - ITALY Phone : +39-02-27325-1 E-mail: tbd@siaemic.com

Imports

FromSymbols
SIAE-ALARM-MIBAlarmSeverityCode, AlarmStatus
SIAE-TREE-MIBsiaeMib
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

SIAE-ALARM-MIB
SIAE-PMG828-MIB
SIAE-TREE-MIB
SIAE-USER-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
pmG828MibVersion
OBJECT-TYPE
Numerical version of this module. The string version of this MIB have the following format: XX.YY.ZZ so, for example, the value 1 should be interpreted as 00.00.01 and the value 10001 should be interpreted as 01.00.01.
1.3.6.1.4.1.3373.1103.11.1INTEGERread-onlycurrent
pmG828CounterTable
OBJECT-TYPE
Table with PmG828 records: one record for 1+0 configuration and two record for 1+1 configuration.
1.3.6.1.4.1.3373.1103.11.2not-accessiblecurrent
pmG828CounterRecord
OBJECT-TYPE
PmG828Counter record.
1.3.6.1.4.1.3373.1103.11.2.1not-accessiblecurrent
pmG828TPointId
OBJECT-TYPE
This object identifies the Termination Point.
1.3.6.1.4.1.3373.1103.11.2.1.1Integer32read-onlycurrent
pmG828CounterBlockId
OBJECT-TYPE
This object identifies the counters block and the counter type according to the following code: 1 Current Daily counters 2 Daily counters (Day before counters) 3 Current 15 minutes counters 4 15 minutes counters N. 1 (The most recent 15 minutes counters) .............................................. n 15 minutes counters N. n 20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before).
1.3.6.1.4.1.3373.1103.11.2.1.2Integer32read-onlycurrent
pmG828CounterBlockType
OBJECT-TYPE
The type of the counter block.
1.3.6.1.4.1.3373.1103.11.2.1.3INTEGER {daily(1), fifteenMin(2)}read-onlycurrent
pmG828CounterBlockStatus
OBJECT-TYPE
Status of the block counter.
1.3.6.1.4.1.3373.1103.11.2.1.4INTEGER {meaningless(1), meaningfull(2), incomplete(3), dummy(4), lost(5), restarted(6)}read-onlycurrent
pmG828CounterTimeStamp
OBJECT-TYPE
The object is the time when the performance record is closed reported as the second number since 1-Gen-1970.
1.3.6.1.4.1.3373.1103.11.2.1.5Unsigned32read-onlycurrent
pmG828BBECounter
OBJECT-TYPE
G828 BBE counter.
1.3.6.1.4.1.3373.1103.11.2.1.6Counter32read-onlycurrent
pmG828ESCounter
OBJECT-TYPE
G828 Es counter.
1.3.6.1.4.1.3373.1103.11.2.1.7Counter32read-onlycurrent
pmG828SESCounter
OBJECT-TYPE
G828 SES counter.
1.3.6.1.4.1.3373.1103.11.2.1.8Counter32read-onlycurrent
pmG828UASCounter
OBJECT-TYPE
G828 UAS counter.
1.3.6.1.4.1.3373.1103.11.2.1.9Counter32read-onlycurrent
pmG828SEPCounter
OBJECT-TYPE
G828 SEP counter.
1.3.6.1.4.1.3373.1103.11.2.1.10Counter32read-onlycurrent
pmG828TpClassTable
OBJECT-TYPE
Table with PmG828TpClass records: one record for 1+0 configuration and two record for 1+1 configuration.
1.3.6.1.4.1.3373.1103.11.3not-accessiblecurrent
pmG828TpClassRecord
OBJECT-TYPE
PmG828TpClass record.
1.3.6.1.4.1.3373.1103.11.3.1not-accessiblecurrent
pmG828TpClassId
OBJECT-TYPE
This object identifies the Termination Point.
1.3.6.1.4.1.3373.1103.11.3.1.1Integer32read-onlycurrent
pmG828TpClassStartStop
OBJECT-TYPE
This object is used to start and to stop the Perfomance Monitoring counter evaluation.
1.3.6.1.4.1.3373.1103.11.3.1.2INTEGER {start(1), stop(2)}read-createcurrent
pmG828TpClassLabel
OBJECT-TYPE
ASCII string used to identify the Tp class: for example: pmG828TpClassBranchId = 1 label = Radio 1 pmG828TpClassBranchId = 2 label = Radio 2 pmG828TpClassBranchId = 3 label = Radio(switched) pmG828TpClassBranchId = 4 label = Trib E1 line side pmG828TpClassBranchId = 5 label = Trib E1 radio side.
1.3.6.1.4.1.3373.1103.11.3.1.3DisplayString (SIZE(0..31))read-onlycurrent
pmG828TpClassTimeStamp
OBJECT-TYPE
1.3.6.1.4.1.3373.1103.11.3.1.4Unsigned32read-onlycurrent
pmG828TpClass15MEsAlarm
OBJECT-TYPE
15 minutes ES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.5AlarmStatusread-onlycurrent
pmG828TpClass15MSesAlarm
OBJECT-TYPE
15 minutes SES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.6AlarmStatusread-onlycurrent
pmG828TpClass15MSepAlarm
OBJECT-TYPE
15 minutes SEP threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.7AlarmStatusread-onlycurrent
pmG828TpClass24HEsAlarm
OBJECT-TYPE
Daily ES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.8AlarmStatusread-onlycurrent
pmG828TpClass24HSesAlarm
OBJECT-TYPE
Daily SES threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.9AlarmStatusread-onlycurrent
pmG828TpClass24HSepAlarm
OBJECT-TYPE
Daily SEP threshold cross alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.10AlarmStatusread-onlycurrent
pmG828TpClassUasAlarm
OBJECT-TYPE
UAS alarm with associated severity.
1.3.6.1.4.1.3373.1103.11.3.1.11AlarmStatusread-onlycurrent
pmG828TpClass15MEsThreshold
OBJECT-TYPE
Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.12Integer32read-createcurrent
pmG828TpClass15MSesThreshold
OBJECT-TYPE
Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.13Integer32read-createcurrent
pmG828TpClass15MSepThreshold
OBJECT-TYPE
Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.14Integer32read-createcurrent
pmG828TpClass24HEsThreshold
OBJECT-TYPE
Number of ES within one day to set pmG828TpClass24HEsAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.15Integer32read-createcurrent
pmG828TpClass24HSesThreshold
OBJECT-TYPE
Number of SES within one day to set pmG828TpClass24HSesAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.16Integer32read-createcurrent
pmG828TpClass24HSepThreshold
OBJECT-TYPE
Number of SEP within one day to set pmG828TpClass24HSepAlarm (zero value disables the alarm).
1.3.6.1.4.1.3373.1103.11.3.1.17Integer32read-createcurrent
pmG828TpClassRowStatus
OBJECT-TYPE
Status of this row of pmRxPwrTpClass.
1.3.6.1.4.1.3373.1103.11.3.1.18RowStatusread-createcurrent
pmG828TpMaintTable
OBJECT-TYPE
Table with Command for maintenance of Termination Point. Objects in this table is not persistent. An Instance of this table is created on creation of pmG828TpClassTable
1.3.6.1.4.1.3373.1103.11.4not-accessiblecurrent
pmG828TpMaintRecord
OBJECT-TYPE
PmG828 Termination Point Maintenance record.
1.3.6.1.4.1.3373.1103.11.4.1not-accessiblecurrent
pmG828TpMaintCounterClear
OBJECT-TYPE
This object is used to clear the Perfomance Monitoring counters.
1.3.6.1.4.1.3373.1103.11.4.1.1INTEGER {notActive(0), clear(1)}read-writecurrent
pmG828TpMaintAlarmClear
OBJECT-TYPE
This object is used to clear the Perfomance Monitoring threshold cross alarms.
1.3.6.1.4.1.3373.1103.11.4.1.2INTEGER {notActive(0), clear(1)}read-writecurrent
pmG828NSesSetUAS
OBJECT-TYPE
Number of SES (according G.828) to set UAS.
1.3.6.1.4.1.3373.1103.11.5Integer32read-writecurrent
pmG828NSesResetUAS
OBJECT-TYPE
Number of seconds whitout errors (according G.828) to reset UAS.
1.3.6.1.4.1.3373.1103.11.6Integer32read-writecurrent
pmG828TpClass15MEsAlarmSeverityCode
OBJECT-TYPE
Defines the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.7AlarmSeverityCoderead-writecurrent
pmG828TpClass15MSesAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.8AlarmSeverityCoderead-writecurrent
pmG828TpClass24HEsAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the pmG828TpClass15MEsAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.9AlarmSeverityCoderead-writecurrent
pmG828TpClass24HSesAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the pmG828TpClass15MSesAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.10AlarmSeverityCoderead-writecurrent
pmG828TpClassUASAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the pmG828TpClassUASAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.11AlarmSeverityCoderead-writecurrent
pmG828TpClass15MSepAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the pmG828TpClass15MSepAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.12AlarmSeverityCoderead-writecurrent
pmG828TpClass24HSepAlarmSeverityCode
OBJECT-TYPE
Define the severity associated to the pmG828TpClass24HSepAlarm and enables/disables the trap generation on status change event.
1.3.6.1.4.1.3373.1103.11.13AlarmSeverityCoderead-writecurrent