SAF-MPMUX-MIB
- Registered at
- 1.3.6.1.4.1.7571.100.1.1.2
- Namespace
- saf
- Source file
SAF-MPMUX-MIB- Digest
sha256:e2f9a0e11ca6b6cd89651cde38987bd9b9eddc889af37c347f81de60f35eba48
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
SAF-MPMUX-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| saf OBJECT-IDENTITY | 1.3.6.1.4.1.7571 | |||
| tehnika OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100 | |||
| microwaveRadio OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1 | |||
| pointToPoint OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1 | |||
| cfm22 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2 | |||
| mpmux OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22 | |||
| terminal OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.1 | |||
| termProduct OBJECT-TYPE Textual name of the model. | 1.3.6.1.4.1.7571.100.1.1.2.22.1.1 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| termDescription OBJECT-TYPE Textual description of the model. | 1.3.6.1.4.1.7571.100.1.1.2.22.1.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| termLocation OBJECT-TYPE Textual description of location (same as PROMT>). | 1.3.6.1.4.1.7571.100.1.1.2.22.1.3 | DisplayString (SIZE(0..255)) | read-write | mandatory |
| termVersion OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.1.4 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| termOperation OBJECT-TYPE System operation. | 1.3.6.1.4.1.7571.100.1.1.2.22.1.5 | INTEGER {none(0), booting(1), ok(2), testing(3), error(4)} | read-only | mandatory |
| termIduTemperature OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.1.6 | INTEGER (-128..127) | read-only | mandatory |
| termFrameErrors OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.1.10 | INTEGER | read-only | mandatory |
| writeConfig OBJECT-TYPE Write Config | 1.3.6.1.4.1.7571.100.1.1.2.22.1.11 | INTEGER | write-only | mandatory |
| restartCPU OBJECT-TYPE Restart CPU | 1.3.6.1.4.1.7571.100.1.1.2.22.1.12 | INTEGER | write-only | mandatory |
| serialNumber OBJECT-TYPE Serial number | 1.3.6.1.4.1.7571.100.1.1.2.22.1.13 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| termRf1CablePowerStatus OBJECT-TYPE Cable status from ODU1 | 1.3.6.1.4.1.7571.100.1.1.2.22.1.14 | INTEGER {off(0), ok(1), short(2), error(3), power-off(4)} | read-only | mandatory |
| termRf2CablePowerStatus OBJECT-TYPE Cable status from ODU2 | 1.3.6.1.4.1.7571.100.1.1.2.22.1.15 | INTEGER {off(0), ok(1), short(2), error(3), power-off(4)} | read-only | mandatory |
| power3V3PS1 OBJECT-TYPE IDU power voltage +3.3V | 1.3.6.1.4.1.7571.100.1.1.2.22.1.16 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| power5VPS1 OBJECT-TYPE IDU power voltage +5V | 1.3.6.1.4.1.7571.100.1.1.2.22.1.17 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerM5VPS1 OBJECT-TYPE IDU power voltage -5V | 1.3.6.1.4.1.7571.100.1.1.2.22.1.18 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerODU1V OBJECT-TYPE ODU power voltage (V) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.19 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerODU1I OBJECT-TYPE ODU power current (A) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.20 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerODU1W OBJECT-TYPE ODU power (W) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.21 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| power3V3PS2 OBJECT-TYPE IDU power voltage +3.3V | 1.3.6.1.4.1.7571.100.1.1.2.22.1.22 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| power5VPS2 OBJECT-TYPE IDU power voltage +5V | 1.3.6.1.4.1.7571.100.1.1.2.22.1.23 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerM5VPS2 OBJECT-TYPE IDU power voltage -5V | 1.3.6.1.4.1.7571.100.1.1.2.22.1.24 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerODU2V OBJECT-TYPE ODU power voltage (V) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.25 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerODU2I OBJECT-TYPE ODU power current (A) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.26 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| powerODU2W OBJECT-TYPE ODU power (W) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.27 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| cpuUsage OBJECT-TYPE CPU usage [%] | 1.3.6.1.4.1.7571.100.1.1.2.22.1.28 | INTEGER | read-only | mandatory |
| termBFrameErr OBJECT-TYPE Background block errors | 1.3.6.1.4.1.7571.100.1.1.2.22.1.29 | Counter | read-only | mandatory |
| termStatCountTime OBJECT-TYPE Stat. count. time | 1.3.6.1.4.1.7571.100.1.1.2.22.1.30 | Gauge | read-only | mandatory |
| termErroredSecond OBJECT-TYPE Err. seconds | 1.3.6.1.4.1.7571.100.1.1.2.22.1.31 | Gauge | read-only | mandatory |
| termSeverelyErroredSecond OBJECT-TYPE Severe err. seconds | 1.3.6.1.4.1.7571.100.1.1.2.22.1.32 | Gauge | read-only | mandatory |
| termSyncLostTime OBJECT-TYPE Sync lost time | 1.3.6.1.4.1.7571.100.1.1.2.22.1.33 | Gauge | read-only | mandatory |
| termAvailableTime OBJECT-TYPE Available time | 1.3.6.1.4.1.7571.100.1.1.2.22.1.34 | Gauge | read-only | mandatory |
| termUnAvailableTime OBJECT-TYPE Unavailable time | 1.3.6.1.4.1.7571.100.1.1.2.22.1.35 | Gauge | read-only | mandatory |
| termBer OBJECT-TYPE Textual representation of BER | 1.3.6.1.4.1.7571.100.1.1.2.22.1.36 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| berAlarm OBJECT-TYPE The BER alarm | 1.3.6.1.4.1.7571.100.1.1.2.22.1.37 | INTEGER | read-only | mandatory |
| remoteAlarm OBJECT-TYPE The Remote alarm | 1.3.6.1.4.1.7571.100.1.1.2.22.1.38 | INTEGER | read-only | mandatory |
| systemAlarm OBJECT-TYPE The SYSTEM alarm | 1.3.6.1.4.1.7571.100.1.1.2.22.1.39 | INTEGER | read-only | mandatory |
| inputABCD OBJECT-TYPE The Input sensor | 1.3.6.1.4.1.7571.100.1.1.2.22.1.40 | INTEGER | read-only | mandatory |
| outputABCD OBJECT-TYPE The Output relays | 1.3.6.1.4.1.7571.100.1.1.2.22.1.41 | INTEGER | read-write | mandatory |
| termBerInPwOf10 OBJECT-TYPE The Power of 10 part of termBer | 1.3.6.1.4.1.7571.100.1.1.2.22.1.42 | INTEGER | read-only | optional |
| outputMaskABCD OBJECT-TYPE The Output relay bit mask. If the correspondig bit is 0 - the output bit can be changed manualy 1 - the output bit changes automaticaly (according to sync lost, radio allarm etc.) | 1.3.6.1.4.1.7571.100.1.1.2.22.1.43 | INTEGER | read-write | mandatory |
| baseband OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.2 | |||
| bbVersion OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.2.1 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| bbOperation OBJECT-TYPE System operation. | 1.3.6.1.4.1.7571.100.1.1.2.22.2.2 | INTEGER {none(0), booting(1), ok(2), testing(3), loopback(4), illegalSpeed(5), error(6)} | read-only | mandatory |
| bbLinkCapacity OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.2.3 | INTEGER | read-only | mandatory |
| bbLinkCapacityDescription OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.2.4 | DisplayString (SIZE(0..255)) | read-write | mandatory |
| bbLoopback OBJECT-TYPE Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.2.5 | INTEGER {off(0), digital(1), analog(2)} | read-write | mandatory |
| bbSyncLostAlarm OBJECT-TYPE The SYncLostAlarm. | 1.3.6.1.4.1.7571.100.1.1.2.22.2.6 | INTEGER {none(0), on(1)} | read-only | mandatory |
| radio1 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.3 | |||
| rf1Operation OBJECT-TYPE Radio operation. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.1 | INTEGER {none(0), booting(1), ok(2), testing(3), error(4), noDataFromODU(5)} | read-only | mandatory |
| rf1Alarm OBJECT-TYPE The RadioAlarm. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.2 | INTEGER {none(0), on(1)} | read-only | mandatory |
| rf1Version OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| rf1Side OBJECT-TYPE The Side. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.4 | INTEGER {low(0), high(1)} | read-only | mandatory |
| rf1Channel OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.5 | INTEGER | read-write | mandatory |
| rf1TxFrequency OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.6 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| rf1RxFrequency OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.7 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| rf1TxPower OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.8 | INTEGER | read-write | mandatory |
| rf1RxState OBJECT-TYPE The rx State. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.9 | INTEGER {low(0), ok(1), error(2), loopback(3)} | read-only | mandatory |
| rf1RxLevel OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.10 | INTEGER | read-only | mandatory |
| rf1CableAttenuation OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.11 | INTEGER | read-only | mandatory |
| rf1TxOut OBJECT-TYPE The Tx out. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.12 | INTEGER {error(0), ok(1), off(2)} | read-only | mandatory |
| rf1TxPLL OBJECT-TYPE The txPLL. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.13 | INTEGER {error(0), ok(1)} | read-only | mandatory |
| rf1RxPLL OBJECT-TYPE The rxPLL. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.14 | INTEGER {error(0), ok(1)} | read-only | mandatory |
| rf1OduTemperature OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.15 | INTEGER | read-only | mandatory |
| rf1OduHumidity OBJECT-TYPE The ODU Humidity. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.16 | INTEGER {low(0), high(1)} | read-only | mandatory |
| rf1Loopback OBJECT-TYPE Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.17 | INTEGER {off(0), on(1)} | read-write | mandatory |
| rf1RxAlarmLevel OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.18 | INTEGER | read-write | mandatory |
| rf1txfstart OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.19 | INTEGER | read-only | optional |
| rf1duplexshift OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.20 | INTEGER | read-only | optional |
| rf1chstep OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.21 | INTEGER | read-only | optional |
| rf1chstart OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.22 | INTEGER | read-only | optional |
| rf1chend OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.23 | INTEGER | read-only | optional |
| rf1txpwmin OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.24 | INTEGER | read-only | optional |
| rf1txpwmax OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.25 | INTEGER | read-only | optional |
| rf1txpwstep OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.3.26 | INTEGER | read-only | optional |
| radio2 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.4 | |||
| rf2Operation OBJECT-TYPE Radio operation. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.1 | INTEGER {none(0), booting(1), ok(2), testing(3), error(4), noDataFromODU(5)} | read-only | mandatory |
| rf2Alarm OBJECT-TYPE The RadioAlarm. -> rf1Alarm | 1.3.6.1.4.1.7571.100.1.1.2.22.4.2 | INTEGER {none(0), on(1)} | read-only | optional |
| rf2Version OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| rf2Side OBJECT-TYPE The Side. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.4 | INTEGER {low(0), high(1)} | read-only | mandatory |
| rf2Channel OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.5 | INTEGER | read-write | mandatory |
| rf2TxFrequency OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.6 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| rf2RxFrequency OBJECT-TYPE Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.7 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| rf2TxPower OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.8 | INTEGER | read-write | mandatory |
| rf2RxState OBJECT-TYPE The rx State. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.9 | INTEGER {low(0), ok(1), error(2), loopback(3)} | read-only | mandatory |
| rf2RxLevel OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.10 | INTEGER | read-only | mandatory |
| rf2CableAttenuation OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.11 | INTEGER | read-only | mandatory |
| rf2TxOut OBJECT-TYPE The Tx out. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.12 | INTEGER {error(0), ok(1), off(2)} | read-only | mandatory |
| rf2TxPLL OBJECT-TYPE The txPLL. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.13 | INTEGER {error(0), ok(1)} | read-only | mandatory |
| rf2RxPLL OBJECT-TYPE The rxPLL. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.14 | INTEGER {error(0), ok(1)} | read-only | mandatory |
| rf2OduTemperature OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.15 | INTEGER | read-only | mandatory |
| rf2OduHumidity OBJECT-TYPE The ODU Humidity. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.16 | INTEGER {low(0), high(1)} | read-only | mandatory |
| rf2Loopback OBJECT-TYPE Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.17 | INTEGER {off(0), on(1)} | read-write | mandatory |
| rf2RxAlarmLevel OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.18 | INTEGER | read-write | mandatory |
| rf2txfstart OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.19 | INTEGER | read-only | optional |
| rf2duplexshift OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.20 | INTEGER | read-only | optional |
| rf2chstep OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.21 | INTEGER | read-only | optional |
| rf2chstart OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.22 | INTEGER | read-only | optional |
| rf2chend OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.23 | INTEGER | read-only | optional |
| rf2txpwmin OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.24 | INTEGER | read-only | optional |
| rf2txpwmax OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.25 | INTEGER | read-only | optional |
| rf2txpwstep OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.4.26 | INTEGER | read-only | optional |
| switchCtrl OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.5 | |||
| activeLink OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.1 | INTEGER {unknown(0), link1(1), link2(2), error(255)} | read-write | mandatory |
| activeTx OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.2 | INTEGER {none(0), link1(1), link2(2), both(3)} | read-write | mandatory |
| preferedLink OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.3 | INTEGER {unknown(0), link1(1), link2(2), error(255)} | read-write | optional |
| forcedLink OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.4 | INTEGER {off(0), link1(1), link2(2), error(255)} | read-write | mandatory |
| switchMode OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.5 | INTEGER {unknown(0), freqDiv(1), hotStandby(2), independent(3)} | read-write | mandatory |
| odu1RxMax OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.6 | INTEGER | read-write | mandatory |
| odu2RxMax OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.7 | INTEGER | read-write | mandatory |
| odu1RxMin OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.8 | INTEGER | read-write | mandatory |
| odu2RxMin OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.9 | INTEGER | read-write | mandatory |
| rxDelta OBJECT-TYPE Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.5.10 | INTEGER | read-write | mandatory |
| rxBER OBJECT-TYPE Maximum value of allowed BER | 1.3.6.1.4.1.7571.100.1.1.2.22.5.11 | DisplayString (SIZE(0..255)) | read-write | mandatory |
| switchDelay OBJECT-TYPE Delay (s) | 1.3.6.1.4.1.7571.100.1.1.2.22.5.12 | INTEGER | read-write | mandatory |
| switchEnabledForRxBer OBJECT-TYPE Enable/disable swithing for Rx and BER | 1.3.6.1.4.1.7571.100.1.1.2.22.5.13 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| switchReason OBJECT-TYPE 100 - command SWITCH FORCE OFF 101 - command SWITCH FORCE 1 102 - command SWITCH FORCE 2 103 - command SWITCH ACTIVE 1 104 - command SWITCH ACTIVE 2 105 - active ODU changed from 1 to 2 because of power problems in ODU1 106 - active ODU changed from 2 to 2 because of power problems in ODU2 107 - active ODU changed from 1 to 2 because of cable problems in ODU1 108 - active ODU changed from 2 to 1 because of cable problems in ODU2 109 - active ODU changed from 1 to 2 because of SyncLoss problems when active ODU1 110 - active ODU changed from 2 to 1 because of SyncLoss problems when active ODU2 111 - active ODU changed from 1 to 2 because of RAI problems when active ODU1 112 - active ODU changed from 2 to 1 because of RAI problems when active ODU2 113 - active ODU changed from 1 to 2 because of RXLEV problems in ODU1 114 - active ODU changed from 2 to 1 because of RXLEV problems in ODU2 115 - active ODU changed from 1 to 2 because of BER problems when active ODU1 116 - active ODU changed from 2 to 1 because of BER problems when active ODU2 | 1.3.6.1.4.1.7571.100.1.1.2.22.5.14 | INTEGER | read-only | mandatory |
| modules OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6 | |||
| m1 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1 | |||
| m1Type OBJECT-TYPE The module type. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.1 | INTEGER {error(0), e1x1(30), e1(33), v35(37), bridge(43), t1x4(74), e1x4(78), eow64(100), e3(227), f1bridge(241), f2bridge(242), none(255)} | read-only | mandatory |
| m1Description OBJECT-TYPE Textual description of the module. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m1Version OBJECT-TYPE Module Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m1Speed OBJECT-TYPE Module data speed Integer variable Kbit. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.4 | INTEGER | read-write | mandatory |
| m1Operation OBJECT-TYPE Module operation statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.5 | INTEGER {none(0), booting(1), ok(2), testing(3), loopback(4), illegalSpeed(5), error(6)} | read-only | mandatory |
| m1Rx OBJECT-TYPE Module Rx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.6 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), rxAIS(4), error(5), noData(6)} | read-only | mandatory |
| m1Tx OBJECT-TYPE Module Tx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.7 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), txAIS(4), error(5), noData(6)} | read-only | mandatory |
| m1Loopback OBJECT-TYPE Module Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.8 | INTEGER {off(0), on(1), analog(2)} | read-write | mandatory |
| m1RxInput OBJECT-TYPE Module Rx Input. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.9 | INTEGER {other(0), coax(1), rj45(2), v35(3), e3(4), db25unbalanced(5), db25balanced(6)} | read-write | mandatory |
| m1TxMode OBJECT-TYPE Module Tx duplex mode. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.10 | INTEGER {other(0), halfDuplex(1), fullDuplex(2)} | read-write | mandatory |
| m1TxClockSource OBJECT-TYPE Module Tx clock source. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.11 | INTEGER {other(0), master(1), slave(2)} | read-write | mandatory |
| m1TxClockPhase OBJECT-TYPE Module Tx clock Phase. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.12 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m1DataPolarity OBJECT-TYPE Module data. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.13 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m1ChanCount OBJECT-TYPE Number of data channels | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.14 | INTEGER | read-only | mandatory |
| m1port1 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.21 | |||
| m1p1statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.21.1 | INTEGER | read-only | mandatory |
| m1p1connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.21.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m1p1flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.21.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m1p1priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.21.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m1p1loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.21.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m1port2 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.22 | |||
| m1p2statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.22.1 | INTEGER | read-only | mandatory |
| m1p2connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.22.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m1p2flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.22.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m1p2priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.22.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m1p2loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.22.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m1port3 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.23 | |||
| m1p3statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.23.1 | INTEGER | read-only | mandatory |
| m1p3connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.23.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m1p3flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.23.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m1p3priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.23.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m1p3loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.23.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m1port4 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.24 | |||
| m1p4statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.24.1 | INTEGER | read-only | mandatory |
| m1p4connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.24.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m1p4flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.24.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m1p4priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.24.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m1p4loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.1.24.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m2 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2 | |||
| m2Type OBJECT-TYPE The module type. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.1 | INTEGER {error(0), e1x1(30), e1(33), v35(37), bridge(43), t1x4(74), e1x4(78), eow64(100), e3(227), f1bridge(241), f2bridge(242), none(255)} | read-only | mandatory |
| m2Description OBJECT-TYPE Textual description of the module. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m2Version OBJECT-TYPE Module Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m2Speed OBJECT-TYPE Module data speed Integer variable Kbit. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.4 | INTEGER | read-write | mandatory |
| m2Operation OBJECT-TYPE Module operation statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.5 | INTEGER {none(0), booting(1), ok(2), testing(3), loopback(4), illegalSpeed(5), error(6)} | read-only | mandatory |
| m2Rx OBJECT-TYPE Module Rx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.6 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), rxAIS(4), error(5), noData(6)} | read-only | mandatory |
| m2Tx OBJECT-TYPE Module Tx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.7 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), txAIS(4), error(5), noData(6)} | read-only | mandatory |
| m2Loopback OBJECT-TYPE Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.8 | INTEGER {off(0), on(1), analog(2)} | read-write | mandatory |
| m2RxInput OBJECT-TYPE Module Rx Input. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.9 | INTEGER {other(0), coax(1), rj45(2), v35(3), e3(4), db25unbalanced(5), db25balanced(6)} | read-write | mandatory |
| m2TxMode OBJECT-TYPE Module Tx duplex mode. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.10 | INTEGER {other(0), halfDuplex(1), fullDuplex(2)} | read-write | mandatory |
| m2TxClockSource OBJECT-TYPE Module Tx clock source. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.11 | INTEGER {other(0), master(1), slave(2)} | read-write | mandatory |
| m2TxClockPhase OBJECT-TYPE Module Tx clock Phase. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.12 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m2DataPolarity OBJECT-TYPE Module data. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.13 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m2ChanCount OBJECT-TYPE Number of data channels | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.14 | INTEGER | read-only | mandatory |
| m2port1 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.21 | |||
| m2p1statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.21.1 | INTEGER | read-only | mandatory |
| m2p1connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.21.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m2p1flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.21.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m2p1priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.21.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m2p1loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.21.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m2port2 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.22 | |||
| m2p2statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.22.1 | INTEGER | read-only | mandatory |
| m2p2connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.22.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m2p2flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.22.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m2p2priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.22.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m2p2loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.22.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m2port3 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.23 | |||
| m2p3statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.23.1 | INTEGER | read-only | mandatory |
| m2p3connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.23.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m2p3flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.23.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m2p3priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.23.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m2p3loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.23.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m2port4 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.24 | |||
| m2p4statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.24.1 | INTEGER | read-only | mandatory |
| m2p4connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.24.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m2p4flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.24.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m2p4priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.24.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m2p4loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.2.24.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m3 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3 | |||
| m3Type OBJECT-TYPE The module type. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.1 | INTEGER {error(0), e1x1(30), e1(33), v35(37), bridge(43), t1x4(74), e1x4(78), eow64(100), e3(227), f1bridge(241), f2bridge(242), none(255)} | read-only | mandatory |
| m3Description OBJECT-TYPE Textual description of the module. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m3Version OBJECT-TYPE Module Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m3Speed OBJECT-TYPE Module data speed Integer variable Kbit. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.4 | INTEGER | read-write | mandatory |
| m3Operation OBJECT-TYPE Module operation statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.5 | INTEGER {none(0), booting(1), ok(2), testing(3), loopback(4), illegalSpeed(5), error(6)} | read-only | mandatory |
| m3Rx OBJECT-TYPE Module Rx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.6 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), rxAIS(4), error(5), noData(6)} | read-only | mandatory |
| m3Tx OBJECT-TYPE Module Tx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.7 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), txAIS(4), error(5), noData(6)} | read-only | mandatory |
| m3Loopback OBJECT-TYPE Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.8 | INTEGER {off(0), on(1), analog(2)} | read-write | mandatory |
| m3RxInput OBJECT-TYPE Module Rx Input. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.9 | INTEGER {other(0), coax(1), rj45(2), v35(3), e3(4), db25unbalanced(5), db25balanced(6)} | read-write | mandatory |
| m3TxMode OBJECT-TYPE Module Tx duplex mode. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.10 | INTEGER {other(0), halfDuplex(1), fullDuplex(2)} | read-write | mandatory |
| m3TxClockSource OBJECT-TYPE Module Tx clock source. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.11 | INTEGER {other(0), master(1), slave(2)} | read-write | mandatory |
| m3TxClockPhase OBJECT-TYPE Module Tx clock Phase. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.12 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m3DataPolarity OBJECT-TYPE Module data. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.13 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m3ChanCount OBJECT-TYPE Number of data channels | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.14 | INTEGER | read-only | mandatory |
| m3port1 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.21 | |||
| m3p1statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.21.1 | INTEGER | read-only | mandatory |
| m3p1connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.21.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m3p1flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.21.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m3p1priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.21.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m3p1loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.21.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m3port2 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.22 | |||
| m3p2statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.22.1 | INTEGER | read-only | mandatory |
| m3p2connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.22.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m3p2flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.22.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m3p2priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.22.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m3p2loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.22.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m3port3 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.23 | |||
| m3p3statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.23.1 | INTEGER | read-only | mandatory |
| m3p3connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.23.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m3p3flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.23.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m3p3priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.23.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m3p3loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.23.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m3port4 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.24 | |||
| m3p4statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.24.1 | INTEGER | read-only | mandatory |
| m3p4connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.24.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m3p4flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.24.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m3p4priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.24.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m3p4loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.3.24.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m4 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4 | |||
| m4Type OBJECT-TYPE The module type. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.1 | INTEGER {error(0), e1x1(30), e1(33), v35(37), bridge(43), t1x4(74), e1x4(78), eow64(100), e3(227), f1bridge(241), f2bridge(242), none(255)} | read-only | mandatory |
| m4Description OBJECT-TYPE Textual description of the module. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m4Version OBJECT-TYPE Module Textual version. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| m4Speed OBJECT-TYPE Module data speed Integer variable Kbit. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.4 | INTEGER | read-write | mandatory |
| m4Operation OBJECT-TYPE Module operation statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.5 | INTEGER {none(0), booting(1), ok(2), testing(3), loopback(4), illegalSpeed(5), error(6)} | read-only | mandatory |
| m4Rx OBJECT-TYPE Module Rx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.6 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), rxAIS(4), error(5), noData(6)} | read-only | mandatory |
| m4Tx OBJECT-TYPE Module Tx statuss. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.7 | INTEGER {none(0), ok(1), noSignal(2), noLink(3), txAIS(4), error(5), noData(6)} | read-only | mandatory |
| m4Loopback OBJECT-TYPE Loopback Integer variable. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.8 | INTEGER {off(0), on(1), analog(2)} | read-write | mandatory |
| m4RxInput OBJECT-TYPE Module Rx Input. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.9 | INTEGER {other(0), coax(1), rj45(2), v35(3), e3(4), db25unbalanced(5), db25balanced(6)} | read-write | mandatory |
| m4TxMode OBJECT-TYPE Module Tx duplex mode. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.10 | INTEGER {other(0), halfDuplex(1), fullDuplex(2)} | read-write | mandatory |
| m4TxClockSource OBJECT-TYPE Module Tx clock source. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.11 | INTEGER {other(0), master(1), slave(2)} | read-write | mandatory |
| m4TxClockPhase OBJECT-TYPE Module Tx clock Phase. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.12 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m4DataPolarity OBJECT-TYPE Module data. | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.13 | INTEGER {other(0), normal(1), inverse(2)} | read-write | mandatory |
| m4ChanCount OBJECT-TYPE Number of data channels | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.14 | INTEGER | read-only | mandatory |
| m4port1 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.21 | |||
| m4p1statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.21.1 | INTEGER | read-only | mandatory |
| m4p1connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.21.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m4p1flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.21.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m4p1priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.21.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m4p1loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.21.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m4port2 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.22 | |||
| m4p2statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.22.1 | INTEGER | read-only | mandatory |
| m4p2connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.22.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m4p2flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.22.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m4p2priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.22.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m4p2loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.22.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m4port3 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.23 | |||
| m4p3statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.23.1 | INTEGER | read-only | mandatory |
| m4p3connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.23.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m4p3flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.23.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m4p3priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.23.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m4p3loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.23.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
| m4port4 OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.24 | |||
| m4p4statbin OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.24.1 | INTEGER | read-only | mandatory |
| m4p4connection OBJECT-TYPE Note: ds1 means E1 or T1 | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.24.2 | INTEGER {none(0), auto(1), eth10fdx(2), eth10hdx(3), eth100fdx(4), eth100hdx(5), ds1(6)} | read-write | mandatory |
| m4p4flowcntrl OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.24.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| m4p4priority OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.24.4 | INTEGER {low(0), high(1)} | read-write | mandatory |
| m4p4loopback OBJECT-TYPE loopback | 1.3.6.1.4.1.7571.100.1.1.2.22.6.4.24.5 | INTEGER {off(0), analog(1), remote(2), digital(4), remoteANDdigital(6)} | read-write | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| alarmTrap NOTIFICATION-TYPE SAF management Alarm trap. | 1.3.6.1.4.1.7571.100.1.1.2.22.0.0 | |
| alinkTrap NOTIFICATION-TYPE SAF Active Link trap. | 1.3.6.1.4.1.7571.100.1.1.2.22.0.1 |