MIBs Depot

SAF-IPRADIO

Registered at
1.3.6.1.4.1.7571.100.1.1.5
Namespace
saf
Source file
SAF-IPRADIO
Digest
sha256:81fca8da09634392c9d92f7743a36eaf319f1712af10d35f4621c9033492376d

Imports

FromSymbols
IF-MIBifEntry
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
SAF-IPRADIO
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
saf
OBJECT-IDENTITY
1.3.6.1.4.1.7571
tehnika
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100
microwaveRadio
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1
pointToPoint
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1
safip
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5
ipRadio
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1
ipRadioCfg
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.1
ipRadioCfgGeneral
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.1.1
product
OBJECT-TYPE
Name of the model.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.1DisplayString (SIZE(0..255))read-onlymandatory
description
OBJECT-TYPE
Description of the model.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.2DisplayString (SIZE(0..255))read-onlymandatory
hostname
OBJECT-TYPE
The name of the host.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.3DisplayString (SIZE(0..16))read-writemandatory
sysDateAndTime
OBJECT-TYPE
Current date and time set. For SET tenths of seconds ignored.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.4DateAndTimeread-writemandatory
sysTemperature
OBJECT-TYPE
Unit temperature in degrees by Celsius. NB - sw before 2009.03.18 shows in *10 degrees
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.5INTEGERread-onlymandatory
license
OBJECT-TYPE
To set license information. Read allways 'OK'.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.6DisplayString (SIZE(0..255))read-writemandatory
licenseMask
OBJECT-TYPE
Read license mask.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.7INTEGERread-onlymandatory
licenseUpdateStatus
OBJECT-TYPE
Status of last license update operation by setting license using snmp.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.8INTEGER {ok(1), error(2)}read-onlymandatory
radioTable
OBJECT-TYPE
Radio table.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10not-accessiblemandatory
radioEntry
OBJECT-TYPE
Entry containing objects in radio table.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1not-accessiblemandatory
radioIndex
OBJECT-TYPE
A unique value for each radio. Its value represents UNIT: 1 - for 'local'; 2 - for 'remote'
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.1INTEGER {local(1), remote(2)}read-onlymandatory
radioGenStatus
OBJECT-TYPE
A General status of each radio: 1 - 'OK'; 2 - 'error'
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.2INTEGERread-onlymandatory
radioSide
OBJECT-TYPE
Side for duplex communication.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.3INTEGER {high(1), low(2)}read-writemandatory
radioTxPower
OBJECT-TYPE
Tx power of radio transmitter in dBm.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.4INTEGERread-writemandatory
radioRxLevel
OBJECT-TYPE
Received signal level in dBm.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.5INTEGERread-onlymandatory
radioDuplexShift
OBJECT-TYPE
Utilized duplex shift in KHz.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.6INTEGERread-writemandatory
radioLoopback
OBJECT-TYPE
Radio loopback on/off. To set use loopback command.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.7INTEGER {on(1), off(2)}read-onlymandatory
radioTxMute
OBJECT-TYPE
Status of 'Tx mute': 1 - Tx is muted; 2 - Tx is not muted.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.8INTEGER {on(1), off(2)}read-writemandatory
radioTxFrequency
OBJECT-TYPE
Tx frequency in kHz.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.9INTEGERread-writemandatory
radioRxFrequency
OBJECT-TYPE
Rx frequency in kHz.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.10.1.10INTEGERread-onlymandatory
aTPCTable
OBJECT-TYPE
ATPC table
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.11not-accessiblemandatory
aTPCEntry
OBJECT-TYPE
Entry containing objects in ATPC table.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.11.1not-accessiblemandatory
atpcIndex
OBJECT-TYPE
Its value represents UNIT 1 for 'local'; 2 for 'remote'.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.11.1.1INTEGER {local(1), remote(2)}read-onlymandatory
atpcEnabled
OBJECT-TYPE
ATPC status: 1 for 'on'; 2 for 'off'.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.11.1.2INTEGER {enable(1), disable(2)}read-writemandatory
atpcTxPowerCorrection
OBJECT-TYPE
ATPC Tx power correction in dBm.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.11.1.3INTEGERread-onlymandatory
modemTable
OBJECT-TYPE
CFIP modem table.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12not-accessiblemandatory
modemEntry
OBJECT-TYPE
Entry containing objects in modem table.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1not-accessiblemandatory
modemIndex
OBJECT-TYPE
Value represents UNIT: 1 for local; 2 for remote.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.1INTEGER {local(1), remote(2)}read-onlymandatory
modemGeneralStatus
OBJECT-TYPE
A General status of each modem: 1 - 'OK'; 2 - 'error'
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.2INTEGERread-onlymandatory
modemBandwith
OBJECT-TYPE
Modem bandwidth set in KHz.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.3INTEGERread-writemandatory
modemE1T1Channels
OBJECT-TYPE
Number of E1 or T1 channels set.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.4INTEGERread-writemandatory
modemModulation
OBJECT-TYPE
Modem modulation set. Modulution values are following: QPSK - 1, 8PSK - 2, 16QAM - 3, 32QAM - 4, 64QAM - 5, 128QAM - 6, 256QAM - 7. The combination of wide band and ACM calculates as (modulation + 8*is_wide + 16*is_ACM). Note: not all of listed modulations supported by hardware. Plese check manual.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.5INTEGER {qpsk(1), psk8(2), qam16(3), qam32(4), qam64(5), qam128(6), qam256(7), qpsklimited(8), wqpsk(9), wpsk8(10), wqam16(11), wqam32(12), wqam64(13), wqam128(14), wqam256(15), acmqpsk(17), acmpsk8(18), acmqam16(19), acmqam32(20), acmqam64(21), acmqam128(22), acmqam256(23), acmwqpsk(25), acmwpsk8(26), acmwqam16(27), acmwqam32(28), acmwqam64(29), acmwqam128(30), acmwqam256(31), qam4(33), qam8(34), qam4limited(40), wqam4(41), wqam8(42), acmqam4(49), acmqam8(50), acmwqam4(57), acmwqam8(58)}read-onlymandatory
modemTotalCapacity
OBJECT-TYPE
Total capacity set in Kbps.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.6INTEGERread-onlymandatory
modemEthernetCapacity
OBJECT-TYPE
Ethernet capacity set in Kbps.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.7INTEGERread-onlymandatory
modemAcqStatus
OBJECT-TYPE
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.8INTEGERread-onlymandatory
modemLastAcqError
OBJECT-TYPE
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.9INTEGER {success(1), erragc(2), errtiming(3), errfreqsweep(4), errmse(5), errbit(6), errservice(7), errblind(8), errtimeout(9), errstopped(10), errfatal(11)}read-onlymandatory
modemRadialMSE
OBJECT-TYPE
Radial mean square error value *10 in dB. Radial MSE is a method for estimating the signal to noise ratio. ACM engine uses normalized MSE, which is the inverse of SNR. It is calculated by dividing the estimated MSE level with the energy of the received constellation. Radial MSE peak value threshold is dependent on modulation used and LDPC code rate. In case of QPSK it is -8 dB (-10.5 for 'wide'), 16APSK - -13 dB (-18 for 'wide') and 32APSK - -15.5 dB (-21.5 for 'wide'). If the value trespasses this threshold, BER at the output of LDPC decoder will reach the value of 1.0e-06.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.10INTEGERread-onlymandatory
modemInternalAGCgain
OBJECT-TYPE
dBm
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.11INTEGERread-onlymandatory
modemCarrierOffset
OBJECT-TYPE
Carrier frequency offset in Hz.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.12INTEGERread-onlymandatory
modemSymbolRateTx
OBJECT-TYPE
kHz
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.13INTEGERread-onlymandatory
modemSymbolRateRx
OBJECT-TYPE
kHz
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.14INTEGERread-onlymandatory
modemLDPCdecoderStress
OBJECT-TYPE
The load of LDPC (low-density parity-check code) decoder. The LDPC is monitored for the number of errors being corrected on the input of LDPC decoder. LDPC stress value thresholds @ BER 1.0e-06: - for standard settings ~4.0e-02; - for 'wide' option ~ 1.0e-03. As long as LDPC stress value is under the specified thresholds, amount of errors (and BER itself) on the output of LDPC remains at zero level.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.15DisplayString (SIZE(0..255))read-onlymandatory
modemACMengine
OBJECT-TYPE
Status of ACM engine. When 'on', value '1' is shown, when 'off' - value is '2'.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.16INTEGER {on(1), off(2)}read-onlymandatory
modemACMmodulationMin
OBJECT-TYPE
Modem modulation set. Modulution values are following: QPSK - 1, 8PSK - 2, 16QAM - 3, 32QAM - 4, 64QAM - 5, 128QAM - 6, 256QAM - 7. The combination of wide band and ACM calculates as (modulation + 8*is_wide + 16*is_ACM). Note: not all of listed modulations supported by hardware. Plese check manual.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.17INTEGER {qpsk(1), psk8(2), qam16(3), qam32(4), qam64(5), qam128(6), qam256(7), qpsklimited(8), wqpsk(9), wpsk8(10), wqam16(11), wqam32(12), wqam64(13), wqam128(14), wqam256(15), acmqpsk(17), acmpsk8(18), acmqam16(19), acmqam32(20), acmqam64(21), acmqam128(22), acmqam256(23), acmwqpsk(25), acmwpsk8(26), acmwqam16(27), acmwqam32(28), acmwqam64(29), acmwqam128(30), acmwqam256(31), qam4(33), qam8(34), qam4limited(40), wqam4(41), wqam8(42), acmqam4(49), acmqam8(50), acmwqam4(57), acmwqam8(58)}read-writemandatory
modemACMtotalCapacity
OBJECT-TYPE
Total capacity in Kbps set by ACM.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.18INTEGERread-onlymandatory
modemACMethernetCapacity
OBJECT-TYPE
Ethernet capacity in Kbps set by ACM.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.19INTEGERread-onlymandatory
modemStandard
OBJECT-TYPE
Modem operational standard ETSI or ANSI
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.20INTEGER {etsi(1), ansi(2)}read-writemandatory
modemE1T1ChannelMask
OBJECT-TYPE
E1 or T1 channel mask 0x00 - 0x0f
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.21INTEGERread-writemandatory
modemACMmodulationMax
OBJECT-TYPE
Modem modulation set. Modulution values are following: QPSK - 1, 8PSK - 2, 16QAM - 3, 32QAM - 4, 64QAM - 5, 128QAM - 6, 256QAM - 7. The combination of wide band and ACM calculates as (modulation + 8*is_wide + 16*is_ACM). Note: as PSK modulations are now physicaly deprecated, theese are replased with QAM, so for new QAM modulations there are modificatior +32. Note: not all of listed modulations supported by hardware. Plese check manual.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.22INTEGER {qpsk(1), psk8(2), qam16(3), qam32(4), qam64(5), qam128(6), qam256(7), qpsklimited(8), wqpsk(9), wpsk8(10), wqam16(11), wqam32(12), wqam64(13), wqam128(14), wqam256(15), acmqpsk(17), acmpsk8(18), acmqam16(19), acmqam32(20), acmqam64(21), acmqam128(22), acmqam256(23), acmwqpsk(25), acmwpsk8(26), acmwqam16(27), acmwqam32(28), acmwqam64(29), acmwqam128(30), acmwqam256(31), qam4(33), qam8(34), qam4limited(40), wqam4(41), wqam8(42), acmqam4(49), acmqam8(50), acmwqam4(57), acmwqam8(58)}read-writemandatory
modemRowStatus
OBJECT-TYPE
Row status - to update written data for modemBandwith, modemACMmodulationMin, modemACMmodulationMax, modemE1T1ChannelMask.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.12.1.23INTEGER {active(1), notReady(3), undo(4)}read-writemandatory
vlansEnabled
OBJECT-TYPE
unit temperature *10 degrees Celsius
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.13INTEGER {enabled(1), disabled(2), reset(3)}read-writemandatory
vlanTable
OBJECT-TYPE
Vlan table
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14not-accessiblemandatory
vlanEntry
OBJECT-TYPE
entry containing vlan objects
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1not-accessiblemandatory
vlanNumber
OBJECT-TYPE
A unique value for each vlan.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1.1INTEGERread-writemandatory
vlanPortType
OBJECT-TYPE
VLAN port type management, traffic or endpoint
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1.2INTEGER {management(1), none(2), traffic(3), endpoint(4)}read-writemandatory
vlanPortmap
OBJECT-TYPE
display port bindings bitfield 111(bin)
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1.3INTEGERread-onlymandatory
vlanFid
OBJECT-TYPE
a filtering identifier (assigned automagically)
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1.4INTEGERread-onlyoptional
vlanCfgStat
OBJECT-TYPE
enable/disable vlan # or clear row data
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1.5INTEGER {enable(1), disable(2), clear(3)}read-writemandatory
vlanRowStatus
OBJECT-TYPE
Row status (execute configuration on active) Changing any table value sets this value into state notReady. To update row status write value active(1) into this variable.
1.3.6.1.4.1.7571.100.1.1.5.1.1.1.14.1.6INTEGER {active(1), notReady(3), undo(4)}read-writemandatory
ipRadioCfgNetwork
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.1.2
localIp
OBJECT-TYPE
IPv4 Ethernet address of the local unit in a number format(XXX.XXX.XXX.XXX)
1.3.6.1.4.1.7571.100.1.1.5.1.1.2.1IpAddressread-writemandatory
localIpMask
OBJECT-TYPE
IPv4 Ethernet mask of the local unit in a number format (XXX.XXX.XXX.XXX)
1.3.6.1.4.1.7571.100.1.1.5.1.1.2.2IpAddressread-writemandatory
remoteIp
OBJECT-TYPE
IPv4 Ethernet address of the remote unit in a number format (XXX.XXX.XXX.XXX).
1.3.6.1.4.1.7571.100.1.1.5.1.1.2.3IpAddressread-writemandatory
ipRadioMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.2
writeConfig
OBJECT-TYPE
Write Config
1.3.6.1.4.1.7571.100.1.1.5.1.2.1INTEGERwrite-onlymandatory
restartcpu
OBJECT-TYPE
Restart of Mng CPU. Values: 1 - 'cold' restart; 3 - sw
1.3.6.1.4.1.7571.100.1.1.5.1.2.2INTEGERwrite-onlymandatory
loopbacks
OBJECT-TYPE
Set loopback for 1 minute. value error(1) is not writable. Status of loopbacks. Values: 1 - 'error' (not writable); 2 - 'off'; 3 - 'rf' (radio frequency loopback); N/A 2008.10.21 4 - 'if' (intermediate frequency loopback); 5 - 'modem' (modem loopback); 6 - 'far' (far end loopback); N/A 2008.10.21 7 - 'ethernet' (Ethernet loopback); N/A 2008.10.21 8 - 'e1t1-1' (E1/T1 channel 1 loopback); N/A from firmware 1.51 9 - 'e1t1-2' (E1/T1 channel 2 loopback); N/A from firmware 1.51 10 - 'e1t1-3' (E1/T1 channel 3 loopback); N/A from firmware 1.51 11 - 'e1t1-4' (E1/T1 channel 4 loopback); N/A from firmware 1.51 12 - 'multi' (E1/T1 multi - look channel tributary mask)
1.3.6.1.4.1.7571.100.1.1.5.1.2.3INTEGER {error(1), off(2), if(4), modem(5), multi(12)}read-writemandatory
loopback_tributary_mask
OBJECT-TYPE
Loopback mask for E1/T1 channels
1.3.6.1.4.1.7571.100.1.1.5.1.2.4INTEGERread-onlymandatory
ipRadioStat
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.3
ipRadioStatEth
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.3.2
ethRXTruncatedFrames
OBJECT-TYPE
Number of truncated received frames since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.1Counterread-onlymandatory
ethRXLongEvents
OBJECT-TYPE
Number of frames having byte count greater than MAXIMUM FRAME SIZE parameter (1518, 1536 or 1916 bytes) since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.2Counterread-onlymandatory
ethRXVlanTagsDetected
OBJECT-TYPE
Number of VLAN Tags detected since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.3Counterread-onlymandatory
ethRXUnsupOpcodes
OBJECT-TYPE
Number of frames recognized as control frames but contained an Unknown Opcode since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.4Counterread-onlymandatory
ethRXPauseFrames
OBJECT-TYPE
Number of frames received as control frames with valid PAUSE opcodes since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.5Counterread-onlymandatory
ethRXControlFrames
OBJECT-TYPE
Number of frames received as control frames since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.6Counterread-onlymandatory
ethRXDribleNibbles
OBJECT-TYPE
Indicates that following the end of the packet additional 1 to 7 bits are received. A single nibble, named the dribble nibble, is formed but not sent to the system;
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.7Counterread-onlymandatory
ethRXBroadcasts
OBJECT-TYPE
Number of packets, which destination address contained broadcast address, since unit start or statiistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.8Counterread-onlymandatory
ethRXMulticasts
OBJECT-TYPE
Number of packets, which destination address contained multicast address since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.9Counterread-onlymandatory
ethRXDones
OBJECT-TYPE
Reception of packets successfully completed. Number of completed packets since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.10Counterread-onlymandatory
ethRXOutOfRangeErrors
OBJECT-TYPE
Number of frames where Type/Length field larger than 1518 (Type Field) bytes since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.11Counterread-onlymandatory
ethRXLengthCheckerrorsErrors
OBJECT-TYPE
Number of frames where frame length field in the packet does not match the actual data byte length and is not a Type Field since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.12Counterread-onlymandatory
ethRXCRCErrors
OBJECT-TYPE
Number of frames where frame CRC do not match the internally generated CRC since unit start or statistics reset
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.13Counterread-onlymandatory
ethRXCodeErrors
OBJECT-TYPE
Number of packets where one or more nibbles are signalled as errors during reception of the packet since unit start or statistics reset.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.14Counterread-onlymandatory
ethRXFalseCarrierErrors
OBJECT-TYPE
Indicates that following the last receive statistics vector, a false carrier was detected, noted and reported with this the next receive statistics. The false carrier is not associated with this packet. False carrier is activated on the receive channel that does not result in a packet receive attempt being made;
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.15Counterread-onlymandatory
ethRXDvEvent
OBJECT-TYPE
Number of the last receive (Rx) events seen being too short to be valid packets since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.16Counterread-onlymandatory
ethRXPrevPktDropped
OBJECT-TYPE
Indicates that since the last receive (Rx), a packet is dropped (i.e. interframe gap too small).
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.17Counterread-onlymandatory
ethRXByteCounterHi
OBJECT-TYPE
Total number of bytes received (Rx) on the wire since the last unit (re)start or purification of statistics, not counting collided bytes (bits 31:0).
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.18Counterread-onlymandatory
ethRXByteCounterLow
OBJECT-TYPE
Total number of bytes received (Rx) on the wire since the last unit (re)start or purification of statistics, not counting collided bytes (bits 62:32).
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.19Counterread-onlymandatory
ethTXVlanTags
OBJECT-TYPE
Number of VLAN tagged Tx packets since the last unit (re)start or purification of statistics. 32-bit counter.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.21Counterread-onlymandatory
ethTXBackpresEvents
OBJECT-TYPE
Number of times Tx carrier-sense-method backpressure was previously applied since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.22Counterread-onlymandatory
ethTXPauseFrames
OBJECT-TYPE
Number of frames transmitted (Tx) as control frames with valid PAUSE opcodes since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.23Counterread-onlymandatory
ethTXControlFrames
OBJECT-TYPE
Number of frames transmitted (Tx) as control frames since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.24Counterread-onlymandatory
ethTXWireByteCounterHi
OBJECT-TYPE
Total number of bytes transmitted (Tx) on the wire since the last unit (re)start or purification of statistics, including all bytes from collided attempts (bits 31:0).
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.25Counterread-onlymandatory
ethTXWireByteCounterLow
OBJECT-TYPE
Total number of bytes transmitted (Tx) on the wire since the last unit (re)start or purification of statistics, including all bytes from collided attempts (bits 62:32).
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.26Counterread-onlymandatory
ethTXUnderruns
OBJECT-TYPE
Number of underruns occured during frame transmission (Tx) since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.28Counterread-onlymandatory
ethTXGiants
OBJECT-TYPE
Number of Tx frames having byte count greater than the MAXIMUM FRAME SIZE parameter (1516, 1536 or 1916 bytes) since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.29Counterread-onlymandatory
ethTXLateCollisions
OBJECT-TYPE
Number of Tx collisions occurred beyond the collision window (512 bit times) since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.30Counterread-onlymandatory
ethTXMaxCollisions
OBJECT-TYPE
Number of Tx packets aborted after number of collisions exceeded the RETRANSMISSION MAXIMUM parameter since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.31Counterread-onlymandatory
ethTXExcessiveDefers
OBJECT-TYPE
Number of Tx packets deferred in excess of 6,071 nibble times in 100 Mbps mode, or 24,287 bit-times in 10 Mbps mode since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.32Counterread-onlymandatory
ethTXNonExcessiveDefers
OBJECT-TYPE
Number of Tx packets deferred for at least one attempt, but less than an excessive defer since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.33Counterread-onlymandatory
ethTXBroadcasts
OBJECT-TYPE
Number of Tx packets since the last unit (re)start or purification of statistics, which destination address contained broadcast address.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.34Counterread-onlymandatory
ethTXMulticasts
OBJECT-TYPE
Number of Tx packets since the last unit (re)start or purification of statistics, which destination address contained multicast address.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.35Counterread-onlymandatory
ethTXDones
OBJECT-TYPE
Number of packets successfully transmitted (Tx) since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.36Counterread-onlymandatory
ethTXLengthCheckErrors
OBJECT-TYPE
Number of Tx frames since the last unit (re)start or purification of statistics, where length field in the packet does not match the actual data byte length and is not a Type Field
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.38Counterread-onlymandatory
ethTXCRCErrors
OBJECT-TYPE
Number of Tx frames since the last unit (re)start or purification of statistics, where CRC does not match the internally generated CRC.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.39Counterread-onlymandatory
ethTXCollisions
OBJECT-TYPE
Number of collisions the current packet incurred during transmission (Tx) attempts. Note: Bits 19 through 16 are the collision count on any successfully transmitted packet and as such will not show the possible maximum count of 16 collisions.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.40Counterread-onlymandatory
ethTXByteCounterHi
OBJECT-TYPE
Total count of bytes transmitted (Tx) on the wire not including collided bytes (bits 31:0) since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.41Counterread-onlymandatory
ethTXByteCounterLow
OBJECT-TYPE
Total count of bytes transmitted (Tx) on the wire not including collided bytes (bits 62:32) since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.42Counterread-onlymandatory
ethGFPFCSErrors
OBJECT-TYPE
Number of generic framing procedure (GFP) frames with CRC errors received by the de-encapsulation block since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.44Counterread-onlymandatory
ethGFPCHECErrors
OBJECT-TYPE
Number of generic framing procedure (GFP) frames with CHEC errors received by the de-encapsulation block since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.45Counterread-onlymandatory
ethGFPDropedFrames
OBJECT-TYPE
Number of generic framing procedure (GFP) frames that were dropped in the de-encapsulation block since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.46Counterread-onlymandatory
ethGFPDelineationErrors
OBJECT-TYPE
Number of 'lost of synchronization' events since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.47Counterread-onlymandatory
ethQOSRXQ1Frames
OBJECT-TYPE
Number of frames received on Q1 since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.48Counterread-onlymandatory
ethQOSRXQ1Dropped
OBJECT-TYPE
Number of frames dropped on Q1 since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.49Counterread-onlymandatory
ethQOSRXQ2Frames
OBJECT-TYPE
Number of frames received on Q2 since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.50Counterread-onlymandatory
ethQOSRXQ2Dropped
OBJECT-TYPE
Number of frames dropped on Q2 since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.51Counterread-onlymandatory
ethQOSTXFrames
OBJECT-TYPE
Number of frames passed through TX FIFO since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.52Counterread-onlymandatory
ethQOSTXDropped
OBJECT-TYPE
Number of frames dropped in TX FIFO since the last unit (re)start or purification of statistics.
1.3.6.1.4.1.7571.100.1.1.5.1.3.2.53Counterread-onlymandatory
e1t1StatTable
OBJECT-TYPE
E1 (T1) status Table.
1.3.6.1.4.1.7571.100.1.1.5.1.3.3not-accessiblemandatory
e1t1StatEntry
OBJECT-TYPE
Entry containing objects in E1 (T1) table
1.3.6.1.4.1.7571.100.1.1.5.1.3.3.1not-accessiblemandatory
e1t1LOS
OBJECT-TYPE
if signal loss present
1.3.6.1.4.1.7571.100.1.1.5.1.3.3.1.1INTEGER {on(1), off(2)}read-onlymandatory
e1t1AIS
OBJECT-TYPE
if AIS present
1.3.6.1.4.1.7571.100.1.1.5.1.3.3.1.2INTEGER {on(1), off(2)}read-onlymandatory
e1t1ChannelNr
OBJECT-TYPE
e1 channel number (it is not associated with interface number - ifEntry)
1.3.6.1.4.1.7571.100.1.1.5.1.3.3.1.3INTEGERread-onlymandatory
modemStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.7571.100.1.1.5.1.3.4
modemCountTime
OBJECT-TYPE
Count time in seconds
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.1Counterread-onlymandatory
modemErroredBlock
OBJECT-TYPE
Errored block
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.2Counterread-onlymandatory
modemErroredSecond
OBJECT-TYPE
Errored second
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.3Counterread-onlymandatory
modemSeverelyErroredSecond
OBJECT-TYPE
Severely errored second
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.4Counterread-onlymandatory
modemBackgroundBlockErrror
OBJECT-TYPE
Background Block Error
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.5Counterread-onlymandatory
modemTotalBlockNumber
OBJECT-TYPE
Total Block Number
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.6Counterread-onlymandatory
modemErroredSecondRatio
OBJECT-TYPE
Errored Second Ratio
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.7DisplayStringread-onlymandatory
modemSeverelyErroredSecondRatio
OBJECT-TYPE
Severely Errored Second Ratio
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.8DisplayStringread-onlymandatory
modemBackgroundBlockErrorRatio
OBJECT-TYPE
Background Block Error Ratio
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.9DisplayStringread-onlymandatory
modemUptime
OBJECT-TYPE
Uptime (s)
1.3.6.1.4.1.7571.100.1.1.5.1.3.4.10Counterread-onlymandatory
modemUnavailtime
OBJECT-TYPE
Unavailtime (s)