SAF-INTEGRAX-MIB
- Registered at
- 1.3.6.1.4.1.7571.100.1.1.7.10
- Last updated
- 2020-06-26 00:00
- Organization
- SAF Tehnika
- Revisions
- 2020-06-26 00:00, 2020-05-19 00:00, 2020-05-08 00:00, 2020-01-14 00:00, 2019-11-27 00:00, 2019-06-11 00:00, 2019-04-23 00:00, 2019-03-07 00:00, 2019-03-06 00:00, 2019-02-17 00:00
- Namespace
- saf
- Source file
SAF-INTEGRAX-MIB- Digest
sha256:c374a2bb4efc0d39a79fd543b0b62d937cb3468e15880ed7c6a9259241ccf880
Description
SAF Integra-X device management base
Contact
SAF Tehnika technical support <techsupport@saftehnika.com>
Imports
| From | Symbols |
|---|---|
| IANAifType-MIB | IANAifType |
| SAF-ENTERPRISE | pointToPoint |
| SAF-INTEGRA-MIB | safIntegra |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso |
| SNMPv2-TC | DateAndTime, DisplayString, PhysAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB SAF-ENTERPRISE SAF-INTEGRA-MIB SAF-INTEGRAX-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| FixedDiv10 TEXTUAL-CONVENTION Fixed point, two decimals | current | |||
| FixedDiv20 TEXTUAL-CONVENTION Fixed point, two decimals | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| integraXtimestamp OBJECT-TYPE Last data update time | 1.3.6.1.4.1.7571.100.1.1.7.10.1 | DateAndTime | read-only | current |
| integraXradio OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.2 | |||
| integraXradioA OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1 | |||
| integraXradioAtxPower OBJECT-TYPE Output power of radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.1 | Integer32 | read-only | current |
| integraXradioAtxFrequency OBJECT-TYPE Frequency of radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.2 | Integer32 | read-only | current |
| integraXradioArxLevel OBJECT-TYPE Level of the received signal | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.3 | Integer32 | read-only | current |
| integraXradioArxLevelState OBJECT-TYPE Received signal level state | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.4 | INTEGER {ok(1), low(2), high(3), error(4)} | read-only | current |
| integraXradioAside OBJECT-TYPE Radio side: Low/High | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.5 | INTEGER {high(1), low(2), error(3)} | read-only | current |
| integraXradioAtxMute OBJECT-TYPE Status of 'Tx mute' 1 - Tx is muted, 2 - Tx is not muted. 3 - Status information unavailable | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.6 | INTEGER {on(1), off(2), error(3)} | read-only | current |
| integraXradioAtxMuteDuration OBJECT-TYPE Time remaning for Tx to be muted in seconds. To turn mute on send number of seconds between 10 and MAX. To turn mute off send 0. GET will retrieve remaining duration for mute or 0 if Tx mute is turned off. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.7 | Integer32 (0..214748364) | read-only | current |
| integraXradioAduplexShift OBJECT-TYPE Utilized duplex shift in kHz | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.8 | Integer32 | read-only | current |
| integraXradioArxFrequency OBJECT-TYPE Frequency of radio receiver | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.9 | Integer32 | read-only | current |
| integraXradioAtemperature OBJECT-TYPE Radio module temperature | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.10 | FixedDiv10 | read-only | current |
| integraXradioApll OBJECT-TYPE PLL state of local-oscillator generator | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.11 | INTEGER {error(1), ok(2)} | read-only | current |
| integraXradioArangesTable OBJECT-TYPE Network interface port status data. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.12 | not-accessible | current | |
| integraXradioArangeEntry OBJECT-TYPE An entry containing network physical port status info. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.12.1 | not-accessible | current | |
| integraXradioArangeEntryIndex OBJECT-TYPE A unique value, greater than zero, for each range entry. Starts with 1 and is equal to a number of all range parameters. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.12.1.1 | Integer32 (1..2) | read-only | current |
| integraXradioArangeDescr OBJECT-TYPE 'Minimal' and 'maximal' labels | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.12.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraXradioArangeTxPower OBJECT-TYPE Output power ranges for radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.12.1.3 | Integer32 | read-only | current |
| integraXradioArangeTxFrequency OBJECT-TYPE Frequency ranges for radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.1.12.1.4 | Integer32 | read-only | current |
| integraXradioB OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2 | |||
| integraXradioBtxPower OBJECT-TYPE Output power of radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.1 | Integer32 | read-only | current |
| integraXradioBtxFrequency OBJECT-TYPE Frequency of radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.2 | Integer32 | read-only | current |
| integraXradioBrxLevel OBJECT-TYPE Level of the received signal | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.3 | Integer32 | read-only | current |
| integraXradioBrxLevelState OBJECT-TYPE Received signal level state | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.4 | INTEGER {ok(1), low(2), high(3), error(4)} | read-only | current |
| integraXradioBside OBJECT-TYPE Radio side: Low/High | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.5 | INTEGER {high(1), low(2), error(3)} | read-only | current |
| integraXradioBtxMute OBJECT-TYPE Status of 'Tx mute' 1 - Tx is muted, 2 - Tx is not muted. 3 - Status information unavailable | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.6 | INTEGER {on(1), off(2), error(3)} | read-only | current |
| integraXradioBtxMuteDuration OBJECT-TYPE Time remaning for Tx to be muted in seconds. To turn mute on send number of seconds between 10 and MAX. To turn mute off send 0. GET will retrieve remaining duration for mute or 0 if Tx mute is turned off. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.7 | Integer32 (0..214748364) | read-only | current |
| integraXradioBduplexShift OBJECT-TYPE Utilized duplex shift in kHz | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.8 | Integer32 | read-only | current |
| integraXradioBrxFrequency OBJECT-TYPE Frequency of radio receiver | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.9 | Integer32 | read-only | current |
| integraXradioBtemperature OBJECT-TYPE Radio module temperature | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.10 | FixedDiv10 | read-only | current |
| integraXradioBpll OBJECT-TYPE PLL state of local-oscillator generator | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.11 | INTEGER {error(1), ok(2)} | read-only | current |
| integraXradioBrangesTable OBJECT-TYPE Network interface port status data. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.12 | not-accessible | current | |
| integraXradioBrangeEntry OBJECT-TYPE An entry containing network physical port status info. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.12.1 | not-accessible | current | |
| integraXradioBrangeEntryIndex OBJECT-TYPE A unique value, greater than zero, for each range entry. Starts with 1 and is equal to a number of all range parameters. | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.12.1.1 | Integer32 (1..2) | read-only | current |
| integraXradioBrangeDescr OBJECT-TYPE 'Minimal' and 'maximal' labels | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.12.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraXradioBrangeTxPower OBJECT-TYPE Output power ranges for radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.12.1.3 | Integer32 | read-only | current |
| integraXradioBrangeTxFrequency OBJECT-TYPE Frequency ranges for radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.10.2.2.12.1.4 | Integer32 | read-only | current |
| integraXmodem OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.3 | |||
| integraXmodemA OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1 | |||
| integraXmodemAacquireStatus OBJECT-TYPE This is the current status of modem data acquire when queried modem status. For detailed info use modemAcquireLastStatusDetails. | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.1 | INTEGER {acquireInProgress(1), acquireLocked(2), acquireFailed(3)} | read-only | current |
| integraXmodemAnormalizedMse OBJECT-TYPE Current normalized MSE value (floating point value multiplied by 10) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.2 | Integer32 | read-only | current |
| integraXmodemAfecLoad OBJECT-TYPE Decoder stress or FEC load value (floating point in textual representation) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.3 | DisplayString | read-only | current |
| integraXmodemAxpdEst OBJECT-TYPE XPD Estimated value (floating point value multiplied by 10) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.4 | Integer32 | read-only | current |
| integraXmodemAacquireLastStatusDetails OBJECT-TYPE This is the last status of successfull or unsuccessful modem data acquire | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.5 | INTEGER {acquireLocked(1), acquireSweep(4), acquireMSEerror(5), acquireBITerror(6), acquireStopped(12), acquireSMerror(13)} | read-only | current |
| integraXmodemAtemperature OBJECT-TYPE Modem DSP temperature | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.6 | FixedDiv10 | read-only | current |
| integraXmodemArxModulation OBJECT-TYPE Current (actual) Rx Modulation | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.7 | DisplayString | read-only | current |
| integraXmodemAtxModulation OBJECT-TYPE Current (actual) Tx Modulation | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.8 | DisplayString | read-only | current |
| integraXmodemArxCapacity OBJECT-TYPE Rx ethernet capacity in kilobits per second | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.9 | Integer32 | read-only | current |
| integraXmodemAtxCapacity OBJECT-TYPE Tx ethernet capacity in kilobits per second | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.10 | Integer32 | read-only | current |
| integraXmodemAacmEngine OBJECT-TYPE ACM engine status | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.11 | INTEGER {enabled(1), disabled(2), error(3)} | read-only | current |
| integraXmodemAcarrierOffset OBJECT-TYPE Modem carrier offset | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.12 | Integer32 | read-only | current |
| integraXmodemAcountTime OBJECT-TYPE Modem performance count time | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.13 | Counter64 | read-only | current |
| integraXmodemAerroredBlock OBJECT-TYPE Modem performance errored blocks | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.14 | Counter64 | read-only | current |
| integraXmodemAerroredSecond OBJECT-TYPE Modem performance errored seconds | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.15 | Counter64 | read-only | current |
| integraXmodemAseverelyErroredSecond OBJECT-TYPE Modem performance severely errored seconds | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.16 | Counter64 | read-only | current |
| integraXmodemAbackgroundBlockError OBJECT-TYPE Modem performance background block errors | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.17 | Counter64 | read-only | current |
| integraXmodemAtotalBlockNumber OBJECT-TYPE Modem performance total block number | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.18 | Counter64 | read-only | current |
| integraXmodemAerroredSecondRatio OBJECT-TYPE Modem performance errored second ratio | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.19 | DisplayString | read-only | current |
| integraXmodemAseverelyErroredSecondRatio OBJECT-TYPE Modem performance severely errored second ratio | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.20 | DisplayString | read-only | current |
| integraXmodemAbackgroundBlockErrorRatio OBJECT-TYPE Modem performance background block error ratio | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.21 | DisplayString | read-only | current |
| integraXmodemAuptime OBJECT-TYPE Modem performance : uptime | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.22 | Counter64 | read-only | current |
| integraXmodemAunavailtime OBJECT-TYPE Modem performance : unavailtime | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.23 | Counter64 | read-only | current |
| integraXmodemAfecLdpcBlockCounter OBJECT-TYPE Modem FEC load block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.24 | Counter64 | read-only | current |
| integraXmodemAfecLdpcUncorrectedBlockCounter OBJECT-TYPE Modem FEC load uncorrected block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.25 | Counter64 | read-only | current |
| integraXmodemAfecLdpcUncorrectedPercent OBJECT-TYPE Modem FEC load uncorrected percent | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.26 | Integer32 | read-only | current |
| integraXmodemAfecRsBlockCounter OBJECT-TYPE Modem FEC load RS block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.27 | Counter64 | read-only | current |
| integraXmodemAfecRsUncorrectedBlockCounter OBJECT-TYPE Modem FEC load RS uncorrected block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.28 | Counter64 | read-only | current |
| integraXmodemAmodulationACMmin OBJECT-TYPE Minimal modulation for ACM enabled profile | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.29 | DisplayString | read-only | current |
| integraXmodemAmodulationACMmax OBJECT-TYPE Maximal modulation for ACM enabled profile | 1.3.6.1.4.1.7571.100.1.1.7.10.3.1.30 | DisplayString | read-only | current |
| integraXmodemB OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2 | |||
| integraXmodemBacquireStatus OBJECT-TYPE This is the current status of modem data acquire when queried modem status. For detailed info use modemAcquireLastStatusDetails. | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.1 | INTEGER {acquireInProgress(1), acquireLocked(2), acquireFailed(3)} | read-only | current |
| integraXmodemBnormalizedMse OBJECT-TYPE Current normalized MSE value (floating point value multiplied by 10) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.2 | Integer32 | read-only | current |
| integraXmodemBfecLoad OBJECT-TYPE Decoder stress or FEC load value (floating point in textual representation) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.3 | DisplayString | read-only | current |
| integraXmodemBxpdEst OBJECT-TYPE XPD Estimated value (floating point value multiplied by 10) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.4 | Integer32 | read-only | current |
| integraXmodemBacquireLastStatusDetails OBJECT-TYPE This is the last status of successfull or unsuccessful modem data acquire | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.5 | INTEGER {acquireLocked(1), acquireSweep(4), acquireMSEerror(5), acquireBITerror(6), acquireStopped(12), acquireSMerror(13)} | read-only | current |
| integraXmodemBtemperature OBJECT-TYPE Modem DSP temperature | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.6 | FixedDiv10 | read-only | current |
| integraXmodemBrxModulation OBJECT-TYPE Current (actual) Rx Modulation | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.7 | DisplayString | read-only | current |
| integraXmodemBtxModulation OBJECT-TYPE Current (actual) Tx Modulation | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.8 | DisplayString | read-only | current |
| integraXmodemBrxCapacity OBJECT-TYPE Rx ethernet capacity in kilobits per second | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.9 | Integer32 | read-only | current |
| integraXmodemBtxCapacity OBJECT-TYPE Tx ethernet capacity in kilobits per second | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.10 | Integer32 | read-only | current |
| integraXmodemBacmEngine OBJECT-TYPE ACM engine status | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.11 | INTEGER {enabled(1), disabled(2), error(3)} | read-only | current |
| integraXmodemBcarrierOffset OBJECT-TYPE Modem carrier offset | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.12 | Integer32 | read-only | current |
| integraXmodemBcountTime OBJECT-TYPE Modem performance count time | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.13 | Counter64 | read-only | current |
| integraXmodemBerroredBlock OBJECT-TYPE Modem performance errored blocks | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.14 | Counter64 | read-only | current |
| integraXmodemBerroredSecond OBJECT-TYPE Modem performance errored seconds | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.15 | Counter64 | read-only | current |
| integraXmodemBseverelyErroredSecond OBJECT-TYPE Modem performance severely errored seconds | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.16 | Counter64 | read-only | current |
| integraXmodemBbackgroundBlockError OBJECT-TYPE Modem performance background block errors | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.17 | Counter64 | read-only | current |
| integraXmodemBtotalBlockNumber OBJECT-TYPE Modem performance total block number | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.18 | Counter64 | read-only | current |
| integraXmodemBerroredSecondRatio OBJECT-TYPE Modem performance errored second ratio | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.19 | DisplayString | read-only | current |
| integraXmodemBseverelyErroredSecondRatio OBJECT-TYPE Modem performance severely errored second ratio | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.20 | DisplayString | read-only | current |
| integraXmodemBbackgroundBlockErrorRatio OBJECT-TYPE Modem performance background block error ratio | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.21 | DisplayString | read-only | current |
| integraXmodemBuptime OBJECT-TYPE Modem performance : uptime | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.22 | Counter64 | read-only | current |
| integraXmodemBunavailtime OBJECT-TYPE Modem performance : unavailtime | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.23 | Counter64 | read-only | current |
| integraXmodemBfecLdpcBlockCounter OBJECT-TYPE Modem FEC load block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.24 | Counter64 | read-only | current |
| integraXmodemBfecLdpcUncorrectedBlockCounter OBJECT-TYPE Modem FEC load uncorrected block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.25 | Counter64 | read-only | current |
| integraXmodemBfecLdpcUncorrectedPercent OBJECT-TYPE Modem FEC load uncorrected percent | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.26 | Integer32 | read-only | current |
| integraXmodemBfecRsBlockCounter OBJECT-TYPE Modem FEC load RS block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.27 | Counter64 | read-only | current |
| integraXmodemBfecRsUncorrectedBlockCounter OBJECT-TYPE Modem FEC load RS uncorrected block counter | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.28 | Counter64 | read-only | current |
| integraXmodemBmodulationACMmin OBJECT-TYPE Minimal modulation for ACM enabled profile | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.29 | DisplayString | read-only | current |
| integraXmodemBmodulationACMmax OBJECT-TYPE Maximal modulation for ACM enabled profile | 1.3.6.1.4.1.7571.100.1.1.7.10.3.2.30 | DisplayString | read-only | current |
| integraXmodemBandwidth OBJECT-TYPE Signal bandwidth | 1.3.6.1.4.1.7571.100.1.1.7.10.3.3 | Integer32 | read-only | current |
| integraXmodemModulation OBJECT-TYPE Modulation (preferred) | 1.3.6.1.4.1.7571.100.1.1.7.10.3.4 | DisplayString | read-only | current |
| integraXsystem OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.4 | |||
| integraXsysCPUtemperature OBJECT-TYPE System CPU temperature | 1.3.6.1.4.1.7571.100.1.1.7.10.4.2 | FixedDiv10 | read-only | current |
| integraXsysLicenseExpire OBJECT-TYPE License expires after number of seconds. In the case of -1, check licenseGenStatus status | 1.3.6.1.4.1.7571.100.1.1.7.10.4.3 | Gauge32 | read-only | current |
| integraXsysLicenseGenStatus OBJECT-TYPE License General status. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.4 | INTEGER {ok(1), expired(2), unknown(3), unlimitedTime(4)} | read-only | current |
| integraXsysPSUvoltage OBJECT-TYPE Power voltage in mV | 1.3.6.1.4.1.7571.100.1.1.7.10.4.5 | Integer32 | read-only | current |
| integraXsysPSUcurrent OBJECT-TYPE Power current in mA | 1.3.6.1.4.1.7571.100.1.1.7.10.4.6 | Integer32 | read-only | current |
| integraXsysPSUpower OBJECT-TYPE Power consumption in mW | 1.3.6.1.4.1.7571.100.1.1.7.10.4.7 | Integer32 | read-only | current |
| integraXsysBoardTemperature OBJECT-TYPE System temperature | 1.3.6.1.4.1.7571.100.1.1.7.10.4.8 | FixedDiv10 | read-only | current |
| integraXsysFreeMemory OBJECT-TYPE System free memory | 1.3.6.1.4.1.7571.100.1.1.7.10.4.9 | FixedDiv10 | read-only | current |
| integraXsysCPUidle OBJECT-TYPE System CPU idle | 1.3.6.1.4.1.7571.100.1.1.7.10.4.10 | FixedDiv10 | read-only | current |
| integraXsysDeviceType OBJECT-TYPE Device type name | 1.3.6.1.4.1.7571.100.1.1.7.10.4.11 | DisplayString | read-only | current |
| integraXsysDeviceSerial OBJECT-TYPE Device serial number | 1.3.6.1.4.1.7571.100.1.1.7.10.4.12 | DisplayString | read-only | current |
| integraXsysDeviceProductModel OBJECT-TYPE Device product model code | 1.3.6.1.4.1.7571.100.1.1.7.10.4.13 | DisplayString | read-only | current |
| integraXsysFanError OBJECT-TYPE Device fan 1 and fan 2 error status | 1.3.6.1.4.1.7571.100.1.1.7.10.4.14 | Bits {no(0), fan1(1), fan2(2), unknown(3)} | read-only | current |
| integraXsysSw1v0core OBJECT-TYPE SW_1V0_CORE | 1.3.6.1.4.1.7571.100.1.1.7.10.4.15 | FixedDiv20 | read-only | current |
| integraXsysSw1v0avdd OBJECT-TYPE SW_1V0_AVDD | 1.3.6.1.4.1.7571.100.1.1.7.10.4.16 | FixedDiv20 | read-only | current |
| integraXsysSw1v2a OBJECT-TYPE SW_1V2A | 1.3.6.1.4.1.7571.100.1.1.7.10.4.17 | FixedDiv20 | read-only | current |
| integraXsysSw1v5ddr OBJECT-TYPE SW_1V5_DDR | 1.3.6.1.4.1.7571.100.1.1.7.10.4.18 | FixedDiv20 | read-only | current |
| integraXsysSw1v8 OBJECT-TYPE SW_1V8 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.19 | FixedDiv20 | read-only | current |
| integraXsysSw2v5 OBJECT-TYPE SW_2V5 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.20 | FixedDiv20 | read-only | current |
| integraXsysSw3v3 OBJECT-TYPE SW_3V3 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.21 | FixedDiv20 | read-only | current |
| integraXsysVttrefPs OBJECT-TYPE VTTVREF_PS | 1.3.6.1.4.1.7571.100.1.1.7.10.4.22 | FixedDiv20 | read-only | current |
| integraXsysVttddrPs OBJECT-TYPE VTTDDR_PS | 1.3.6.1.4.1.7571.100.1.1.7.10.4.23 | FixedDiv20 | read-only | current |
| integraXsysZq1v0 OBJECT-TYPE ZQ_1V0 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.24 | FixedDiv20 | read-only | current |
| integraXsysZq1v5 OBJECT-TYPE ZQ_1V5 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.25 | FixedDiv20 | read-only | current |
| integraXsysZq1v8 OBJECT-TYPE ZQ_1V8 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.26 | FixedDiv20 | read-only | current |
| integraXsysZq2v5 OBJECT-TYPE ZQ_2V5 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.27 | FixedDiv20 | read-only | current |
| integraXsysZq3v3 OBJECT-TYPE ZQ_3V3 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.28 | FixedDiv20 | read-only | current |
| integraXsys5v0d OBJECT-TYPE 5V0D | 1.3.6.1.4.1.7571.100.1.1.7.10.4.29 | FixedDiv20 | read-only | current |
| integraXsysSw1v2 OBJECT-TYPE SW_1V2 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.30 | FixedDiv20 | read-only | current |
| integraXsysMdmVddcAvs OBJECT-TYPE MDM_VDDC_AVS | 1.3.6.1.4.1.7571.100.1.1.7.10.4.31 | FixedDiv20 | read-only | current |
| integraXsysMdm3v3 OBJECT-TYPE MDM_3V3 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.32 | FixedDiv20 | read-only | current |
| integraXsysMdm1v0aPm OBJECT-TYPE MDM_1V0A_PM | 1.3.6.1.4.1.7571.100.1.1.7.10.4.33 | FixedDiv20 | read-only | current |
| integraXsysMdm1v0a OBJECT-TYPE MDM_1V0A | 1.3.6.1.4.1.7571.100.1.1.7.10.4.34 | FixedDiv20 | read-only | current |
| integraXsysMdm1v8a OBJECT-TYPE MDM_1V8A | 1.3.6.1.4.1.7571.100.1.1.7.10.4.35 | FixedDiv20 | read-only | current |
| integraXsysMdmDAC02v5a OBJECT-TYPE MDM_DAC0_2V5A | 1.3.6.1.4.1.7571.100.1.1.7.10.4.36 | FixedDiv20 | read-only | current |
| integraXsysMdmDAC12v5 OBJECT-TYPE MDM_DAC1_2V5A | 1.3.6.1.4.1.7571.100.1.1.7.10.4.37 | FixedDiv20 | read-only | current |
| integraXsysMdmDAC22v5 OBJECT-TYPE MDM_DAC2_2V5A | 1.3.6.1.4.1.7571.100.1.1.7.10.4.38 | FixedDiv20 | read-only | current |
| integraXsysMdm1v8io OBJECT-TYPE MDM_1V8_IO | 1.3.6.1.4.1.7571.100.1.1.7.10.4.39 | FixedDiv20 | read-only | current |
| integraXsysMdm3v3io OBJECT-TYPE MDM_3V3_IO | 1.3.6.1.4.1.7571.100.1.1.7.10.4.40 | FixedDiv20 | read-only | current |
| integraXsys3v3Radio OBJECT-TYPE 3V3_RADIO | 1.3.6.1.4.1.7571.100.1.1.7.10.4.41 | FixedDiv20 | read-only | current |
| integraXsysMdm4v0 OBJECT-TYPE MDM_4V0 | 1.3.6.1.4.1.7571.100.1.1.7.10.4.42 | FixedDiv20 | read-only | current |
| integraXsys5v0nRadio OBJECT-TYPE 5V0N_RADIO | 1.3.6.1.4.1.7571.100.1.1.7.10.4.43 | FixedDiv20 | read-only | current |
| integraXsysCoreVddSns OBJECT-TYPE CORE_VDD_SNS | 1.3.6.1.4.1.7571.100.1.1.7.10.4.44 | FixedDiv20 | read-only | current |
| integraXsys40v0RadioSns OBJECT-TYPE 40V0_RADIO_SNS | 1.3.6.1.4.1.7571.100.1.1.7.10.4.45 | FixedDiv20 | read-only | current |
| integraXsysServices OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46 | |||
| integraXsysServicesReboot OBJECT-TYPE This object can only be set to 1. It initiates system reboot immediately. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.1 | INTEGER {reboot(1)} | read-write | current |
| integraXsysServicesFtpSwitch OBJECT-TYPE Status and on/off switch for the FTP server | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.2 | INTEGER {disabled(1), enabled(2), unknown(3)} | read-write | current |
| integraXsysServicesFwCurrInfo OBJECT-TYPE Currently running FW info. Same output as in RFC1213-MIB::sysDescr. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.3 | DisplayString (SIZE(0..255)) | read-only | current |
| integraXsysServicesFwAvailView OBJECT-TYPE List FW available for installation (uploaded). | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.4 | DisplayString | read-only | current |
| integraXsysServicesFwRemove OBJECT-TYPE Remove available (uploaded) FW version. View FW versions in integraXsysServicesFwAvailView. Send number corresponding to info in integraXsysServicesFwAvailView. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.5 | INTEGER {candfw1(1), candfw2(2), candfw3(3), candfw4(4), candfw5(5)} | read-write | current |
| integraXsysServicesFwRemoveAll OBJECT-TYPE Remove all available (uploaded) FW versions. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.6 | INTEGER {removeAllCandfw(1)} | read-write | current |
| integraXsysServicesFwUpload OBJECT-TYPE Upload FW (make available for installation). You need to upload a firmware to FTP ftp://anonymous@DEVICE_IP:/firmware/ first! You must have only 1 firmware in firmware folder for this option to work! This option only starts upload on the device and doesn't return success status for it. Usually you should wait some time while the device completes upload. SNMP won't response to quieries while upload is in progress. You may check integraXsysServicesFwAvailView to see if your FW is ready for install. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.7 | INTEGER {upload(1)} | read-write | current |
| integraXsysServicesFwInst OBJECT-TYPE Install FW version. You need check integraXsysServicesFwAvailView to see FW versions ready for install. This option only starts installation on the device and doesn't return success status for it. Usually you should wait some time while the device completes installation. SNMP won't response to quieries while upload is in progress. If FW installation was successful, integraXsysServicesFwSwitchNext will show different FW bank value for the next boot. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.8 | INTEGER {candfw1(1), candfw2(2), candfw3(3), candfw4(4), candfw5(5)} | read-write | current |
| integraXsysServicesFwSwitchRunning OBJECT-TYPE FW running bank info. Use integraXsysServicesFwSwitchNext to view and switch FW bank for the next boot. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.9 | INTEGER {fw1(1), fw2(2)} | read-only | current |
| integraXsysServicesFwSwitchNext OBJECT-TYPE FW next boot bank info. Set request can change FW bank for the next boot. View running FW bank number in integraXsysServicesFwSwitchRunning. | 1.3.6.1.4.1.7571.100.1.1.7.10.4.46.10 | INTEGER {fw1(1), fw2(2)} | read-write | current |
| integraXethernet OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.5 | |||
| integraXifStatusTable OBJECT-TYPE Network interface port status data. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1 | not-accessible | current | |
| integraXifPortEntry OBJECT-TYPE An entry containing network physical port status info. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1 | not-accessible | current | |
| integraXifPortStatIndex OBJECT-TYPE A unique value, greater than zero, for each physical network interface. It is recommended that values are assigned contiguously starting from 1. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.1 | Integer32 (1..4) | read-only | current |
| integraXifPortStatDescr OBJECT-TYPE Physical network interface description. LAN1 is electrical, LAN2 and LAN3 are SFP and WAN is radio port. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraXifPortType OBJECT-TYPE The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.3 | IANAifType | read-only | current |
| integraXifPortMtu OBJECT-TYPE Maximum transmission unit value in bytes. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.4 | Integer32 | read-only | current |
| integraXifPortHighSpeed OBJECT-TYPE Link speed in 1 000 000 * bits per second. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.5 | Gauge32 | read-only | current |
| integraXifPortPhysAddress OBJECT-TYPE The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.6 | PhysAddress | read-only | current |
| integraXifPortAdminStatus OBJECT-TYPE Desired state of network interfaces. Interfaces can be enabled(1), disabled(2), unknown(3) (no info received). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.7 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | current |
| integraXifPortOperStatus OBJECT-TYPE Actual state of interfaces. Link can be up(1), down(2) or in unknown(3) state. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.8 | INTEGER {up(1), down(2), unknown(3)} | read-only | current |
| integraXifPortLastChange OBJECT-TYPE This parameter value is always 0 at the moment. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.9 | TimeTicks | read-only | current |
| integraXifPortAutoneg OBJECT-TYPE Auto-negotiation status. Unknown means no info was received. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.10 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | current |
| integraXifPortDuplex OBJECT-TYPE Duplex status for the interface. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.11 | INTEGER {full(1), half(2), unknown(3)} | read-only | current |
| integraXifPortSyncEthActive OBJECT-TYPE Synchronous Ethernet status. Can be active(1) or inactive(0). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.12 | INTEGER {off(0), on(1)} | read-only | current |
| integraXifPortSyncEthPrio OBJECT-TYPE Synchronous Ethernet priority. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.13 | Integer32 | read-only | current |
| integraXifPortFlowControl OBJECT-TYPE Flow control status. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.1.1.14 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | current |
| integraXifStatisticsTable OBJECT-TYPE Network interface port statistics data. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2 | not-accessible | current | |
| integraXifPortStcEntry OBJECT-TYPE An entry containing network physical port statistics counter data. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1 | not-accessible | current | |
| integraXifPortStcIndex OBJECT-TYPE A unique value, greater than zero, for each physical network interface. It is recommended that values are assigned contiguously starting from 1. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.1 | Integer32 (1..5) | read-only | current |
| integraXifPortStcDescr OBJECT-TYPE Physical network interface description. LAN1 is electrical, LAN2 and LAN3 are SFP, WAN is radio port and MNG is internal management interface. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraXifTimePassed OBJECT-TYPE Statistics collection time. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.3 | TimeTicks | read-only | current |
| integraXifIngressPackets OBJECT-TYPE Packets that ingress on the port. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.4 | Counter64 | read-only | current |
| integraXifIngressBytes OBJECT-TYPE Bytes that ingress on the port. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.5 | Counter64 | read-only | current |
| integraXifEgressPackets OBJECT-TYPE Packets that egress on the port. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.6 | Counter64 | read-only | current |
| integraXifEgressBytes OBJECT-TYPE Bytes that egress on the port. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.7 | Counter64 | read-only | current |
| integraXifEtherStatsMulticastPkts OBJECT-TYPE The total number of good packets (both received and transmitted) that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.8 | Counter64 | read-only | current |
| integraXifEtherStatsBroadcastPkts OBJECT-TYPE The total number of good packets (both received and transmitted) that were directed to the broadcast address. Note that this does not include multicast packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.9 | Counter64 | read-only | current |
| integraXifEtherStatsPkts64Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were 64 octets in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.10 | Counter64 | read-only | current |
| integraXifEtherStatsPkts65to127Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.11 | Counter64 | read-only | current |
| integraXifEtherStatsPkts128to255Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.12 | Counter64 | read-only | current |
| integraXifEtherStatsPkts256to511Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.13 | Counter64 | read-only | current |
| integraXifEtherStatsPkts512to1023Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.14 | Counter64 | read-only | current |
| integraXifEtherStatsPkts1024to1518Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.15 | Counter64 | read-only | current |
| integraXifEtherStatsOversizePkts OBJECT-TYPE The number of packets (both received and transmitted) that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.16 | Counter64 | read-only | current |
| integraXifEtherRxOversizePkts OBJECT-TYPE The number of packets received that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.17 | Counter64 | read-only | current |
| integraXifEtherTxOversizePkts OBJECT-TYPE The number of packets transmitted that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.18 | Counter64 | read-only | current |
| integraXifEtherStatsOctets OBJECT-TYPE Total number of octets of data (including those in bad packets) both received and transmitted. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.19 | Counter64 | read-only | current |
| integraXifEtherStatsPkts OBJECT-TYPE Total number of packets (including bad packets) both received and transmitted. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.20 | Counter64 | read-only | current |
| integraXifEtherStatsTXNoErrors OBJECT-TYPE Number of packets that were transmitted without errors. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.21 | Counter64 | read-only | current |
| integraXifEtherStatsRXNoErrors OBJECT-TYPE Number of packets that were received without errors. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.22 | Counter64 | read-only | current |
| integraXifEtherStatsPkts1519to1522Octets OBJECT-TYPE The total number of packets (including bad packets) (both received and transmitted) that were between 1519 and 1522 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.23 | Counter64 | read-only | current |
| integraXifIfInOctets OBJECT-TYPE Total number of octets of data (including those in bad packets) that were received. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.24 | Counter64 | read-only | current |
| integraXifIfOutOctets OBJECT-TYPE Total number of octets of data (including those in bad packets) that were transmitted. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.25 | Counter64 | read-only | current |
| integraXifDot1dTpPortInFrames OBJECT-TYPE The number of frames that have been received by this port from its segment. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.26 | Counter64 | read-only | current |
| integraXifDot1dTpPortOutFrames OBJECT-TYPE The number of frames that have been transmitted by this port to its segment. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.27 | Counter64 | read-only | current |
| integraXifReceivedPkts64Octets OBJECT-TYPE Total number of received packets that were 64 octets in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.28 | Counter64 | read-only | current |
| integraXifTransmittedPkts64Octets OBJECT-TYPE Total number of transmitted packets that were 64 octets in length (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.29 | Counter64 | read-only | current |
| integraXifReceivedPkts65to127Octets OBJECT-TYPE Total number of received packets that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.30 | Counter64 | read-only | current |
| integraXifTransmittedPkts65to127Octets OBJECT-TYPE Total number of transmitted packets that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.31 | Counter64 | read-only | current |
| integraXifReceivedPkts128to255Octets OBJECT-TYPE Total number of received packets that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.32 | Counter64 | read-only | current |
| integraXifTransmittedPkts128to255Octets OBJECT-TYPE Total number of transmitted packets that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.33 | Counter64 | read-only | current |
| integraXifReceivedPkts256to511Octets OBJECT-TYPE Total number of received packets that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.34 | Counter64 | read-only | current |
| integraXifTransmittedPkts256to511Octets OBJECT-TYPE Total number of transmitted packets that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.35 | Counter64 | read-only | current |
| integraXifReceivedPkts512to1023Octets OBJECT-TYPE Total number of received packets that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.36 | Counter64 | read-only | current |
| integraXifTransmittedPkts512to1023Octets OBJECT-TYPE Total number of transmitted packets that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.37 | Counter64 | read-only | current |
| integraXifReceivedPkts1024to1518Octets OBJECT-TYPE Total number of received packets that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.38 | Counter64 | read-only | current |
| integraXifTransmittedPkts1024to1518Octets OBJECT-TYPE Total number of transmitted packets that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.39 | Counter64 | read-only | current |
| integraXifIfInBroadcastPkts OBJECT-TYPE The total number of received good packets that were directed to the broadcast address. Note that this does not include multicast packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.40 | Counter64 | read-only | current |
| integraXifIfOutBroadcastPkts OBJECT-TYPE The total number of transmitted good packets that were directed to the broadcast address. Note that this does not include multicast packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.41 | Counter64 | read-only | current |
| integraXifIfInMulticastPkts OBJECT-TYPE The total number of received good packets that were directed to a multicast address. Note that this number does not include broadcast packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.42 | Counter64 | read-only | current |
| integraXifIfOutMulticastPkts OBJECT-TYPE The total number of transmitted good packets that were directed to a multicast address. Note that this number does not include broadcast packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.43 | Counter64 | read-only | current |
| integraXifDot3InPauseFrames OBJECT-TYPE A count of MAC Control frames received on this interface with an opcode indicating the PAUSE operation. This counter does not increment when the interface is operating in half-duplex mode. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.44 | Counter64 | read-only | current |
| integraXifDot3OutPauseFrames OBJECT-TYPE A count of MAC Control frames transmitted on this interface with an opcode indicating the PAUSE operation. This counter does not increment when the interface is operating in half-duplex mode. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.45 | Counter64 | read-only | current |
| integraXifEtherStatsUndersizePkts OBJECT-TYPE The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.46 | Counter64 | read-only | current |
| integraXifEtherStatsFragments OBJECT-TYPE The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that it is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.47 | Counter64 | read-only | current |
| integraXifEtherStatsCRCAlignErrors OBJECT-TYPE The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.48 | Counter64 | read-only | current |
| integraXifEtherStatsJabbers OBJECT-TYPE The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Note that this definition of jabber is different than the definition in IEEE-802.3 section 8.2.1.5 (10BASE5) and section 10.3.1.4 (10BASE2). These documents define jabber as the condition where any packet exceeds 20 ms. The allowed range to detect jabber is between 20 ms and 150 ms. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.49 | Counter64 | read-only | current |
| integraXifIngressBPS OBJECT-TYPE Ingoing data transfer rate in bytes per second. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.50 | Integer32 | read-only | current |
| integraXifIngressPPS OBJECT-TYPE Ingoing data transfer rate in packets per second. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.51 | Integer32 | read-only | current |
| integraXifEgressBPS OBJECT-TYPE Outgoing data transfer rate in bytes per second. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.52 | Integer32 | read-only | current |
| integraXifEgressPPS OBJECT-TYPE Outgoing data transfer rate in packets per second. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.53 | Integer32 | read-only | current |
| integraXifAllCoSQoutPackets OBJECT-TYPE All CoSQ outgoing packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.54 | Counter64 | read-only | current |
| integraXifAllCoSQoutBytes OBJECT-TYPE All CoSQ outgoing bytes. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.55 | Counter64 | read-only | current |
| integraXifAllCoSQdroppedPackets OBJECT-TYPE All CoSQ dropped packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.56 | Counter64 | read-only | current |
| integraXifAllCoSQdroppedBytes OBJECT-TYPE All CoSQ dropped bytes. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.57 | Counter64 | read-only | current |
| integraXifProcessedRxPackets OBJECT-TYPE Processed received packets. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.58 | Counter64 | read-only | current |
| integraXifProcessedRxBytes OBJECT-TYPE Processed received bytes. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.2.1.59 | Counter64 | read-only | current |
| integraXifLspPortAdminState OBJECT-TYPE LSP port status. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.3 | INTEGER {disabled(1), lsp(2), backup(3), unknown(4)} | read-only | current |
| integraXifLspPortList OBJECT-TYPE LSP port status. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.4 | Bits {none(0), lan1(1), lan2(2), lan3(3)} | read-only | current |
| integraXifLspPortStatus OBJECT-TYPE LSP port status. | 1.3.6.1.4.1.7571.100.1.1.7.10.5.5 | INTEGER {lspPortOK(1), lspPortDownBlockedByLSP(2), backupNoLink(3), backupLinkActive(4), backupLinkReady(5), unknown(6)} | read-only | current |
| integraXexecuteConfig OBJECT-TYPE This object can only be set to 1. It initiates new running configuration applying using values, that have been set before. Setting it when no new changes are available will do nothing and return an error. GET will return 0 if there were no errors, while executing configuration or will return a bitmask, that shows which SET requests have failed. Those failed requests will be shown bit wise from LSB as follows: BIT0 radioTxMuteDuration BIT1 radioTxFrequency BIT2 radioTxPower | 1.3.6.1.4.1.7571.100.1.1.7.10.6 | INTEGER {execute(1)} | read-write | current |
| integraXneedStore OBJECT-TYPE This object shows if there is unsaved, but executed (running) configuration. Unsaved changes will be lost after device reboot. Unsaved entities are shown bit wise, starting from LSB as follows: BIT0 Aggregation BIT1 Event log BIT2 Modem BIT3 Network BIT4 Performance BIT5 Radio BIT6 SNMP BIT7 Synchronous Ethernet BIT8 System | 1.3.6.1.4.1.7571.100.1.1.7.10.7 | INTEGER {no(0)} | read-only | current |
| integraXstoreConfig OBJECT-TYPE This object can only be set to 1. It initiates saving of running configuration. It will only work if there are unsaved, but executed (running) changes (configuration). Setting it when no new running configuration is available will do nothing and return an error. | 1.3.6.1.4.1.7571.100.1.1.7.10.8 | INTEGER {store(1)} | read-write | current |
| integraXnetCfg OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.9 | |||
| integraXnetCfgIPaddress OBJECT-TYPE Local IP address | 1.3.6.1.4.1.7571.100.1.1.7.10.9.1 | DisplayString | read-write | current |
| integraXnetCfgIPmask OBJECT-TYPE Local IP mask | 1.3.6.1.4.1.7571.100.1.1.7.10.9.2 | DisplayString | read-write | current |
| integraXnetCfgIPgateway OBJECT-TYPE IP gateway Send '0' or '255.255.255.255' to clear. | 1.3.6.1.4.1.7571.100.1.1.7.10.9.3 | DisplayString | read-write | current |
| integraXnetCfgRemoteIPaddress OBJECT-TYPE Remote IP address | 1.3.6.1.4.1.7571.100.1.1.7.10.9.4 | DisplayString | read-only | current |
| integraXConformance OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.10 | |||
| integraXCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.10.1 | |||
| integraXGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| integraXCompliance MODULE-COMPLIANCE The compliance statement for SNMP engine which implements the SAF Tehnika Integra-X device. | 1.3.6.1.4.1.7571.100.1.1.7.10.10.1.1 | current |
| integraXMiscGroup OBJECT-GROUP misc data | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2.1 | current |
| integraXRadioGroup OBJECT-GROUP Radio group. | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2.2 | current |
| integraXModemGroup OBJECT-GROUP Modem group. | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2.3 | current |
| integraXSystemGroup OBJECT-GROUP System group. | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2.4 | current |
| integraXEthernetGeneralGroup OBJECT-GROUP A collection to objects, providing info applicable to all network interfaces. | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2.5 | current |
| integraXEthernetMiiPortGroup OBJECT-GROUP A collection of objects, providing info applicable only to MII group interfaces. | 1.3.6.1.4.1.7571.100.1.1.7.10.10.2.6 | current |