SAF-INTEGRAW-MIB
- Registered at
- 1.3.6.1.4.1.7571.100.1.1.7.2
- Last updated
- 2016-05-11 00:00
- Organization
- SAF Tehnika
- Revisions
- 2016-05-11 00:00, 2015-09-17 00:00, 2015-09-15 00:00, 2015-08-12 00:00, 2015-07-29 00:00, 2015-05-29 00:00, 2015-05-20 00:00, 2015-04-21 00:00, 2015-04-14 00:00, 2015-03-24 00:00, 2015-02-04 00:00, 2015-01-20 00:00, 2015-01-08 00:00, 2015-01-06 00:00
- Namespace
- saf
- Source file
SAF-INTEGRAW-MIB- Digest
sha256:eef2a8250e1756a8cb64e0f259635787c40d97cf5ff72a5dd5ca1e63715c1412
Description
SAF IntegraW radio management base
Contact
SAF Tehnika technical support <techsupport>
Imports
| From | Symbols |
|---|---|
| IANAifType-MIB | IANAifType |
| SAF-ENTERPRISE | pointToPoint |
| SAF-INTEGRA-MIB | safIntegra |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso |
| SNMPv2-TC | DateAndTime, DisplayString, PhysAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB SAF-ENTERPRISE SAF-INTEGRA-MIB SAF-INTEGRAW-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| integraWtimestamp OBJECT-TYPE Last data update time | 1.3.6.1.4.1.7571.100.1.1.7.2.1 | DateAndTime | read-only | current |
| integraWradio OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.2 | |||
| integraWradioTxPower OBJECT-TYPE Output power of radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.2.2.1 | Integer32 | read-write | current |
| integraWradioTxFrequency OBJECT-TYPE Frequency of radio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.2.2.2 | Integer32 | read-write | current |
| integraWradioRxLevel OBJECT-TYPE Level of the received signal | 1.3.6.1.4.1.7571.100.1.1.7.2.2.3 | Integer32 | read-only | current |
| integraWradioSide OBJECT-TYPE Radio side: Low/High | 1.3.6.1.4.1.7571.100.1.1.7.2.2.4 | INTEGER {high(1), low(2), error(3)} | read-only | current |
| integraWradioTxMute OBJECT-TYPE Status of 'Tx mute' 1 - Tx is muted, 2 - Tx is not muted. 3 - Status information unavailable | 1.3.6.1.4.1.7571.100.1.1.7.2.2.5 | INTEGER {on(1), off(2), error(3)} | read-only | current |
| integraWradioDuplexShift OBJECT-TYPE Utilized duplex shift in kHz | 1.3.6.1.4.1.7571.100.1.1.7.2.2.6 | Integer32 | read-only | current |
| integraWradioRxFrequency OBJECT-TYPE Frequency of radio receiver | 1.3.6.1.4.1.7571.100.1.1.7.2.2.7 | Integer32 | read-only | current |
| integraWradioTemperature OBJECT-TYPE Radio module temperature *10 Celsius | 1.3.6.1.4.1.7571.100.1.1.7.2.2.8 | Integer32 | read-only | current |
| integraWradioTxMuteDuration OBJECT-TYPE Time remaning for Tx to be muted in seconds. To turn mute on send number of seconds between 10 and MAX. To turn mute off send 0. GET will retrieve remaining duration for mute or 0 if Tx mute is turned off. | 1.3.6.1.4.1.7571.100.1.1.7.2.2.9 | Integer32 (0..214748364) | read-write | current |
| integraWradioRangesTable OBJECT-TYPE Network interface port status data. | 1.3.6.1.4.1.7571.100.1.1.7.2.2.10 | not-accessible | current | |
| integraWradioRangeEntry OBJECT-TYPE An entry containing network physical port status info. | 1.3.6.1.4.1.7571.100.1.1.7.2.2.10.1 | not-accessible | current | |
| integraWradioRangeEntryIndex OBJECT-TYPE A unique value, greater than zero, for each range entry. Starts with 1 and is equal to a number of all range parameters. | 1.3.6.1.4.1.7571.100.1.1.7.2.2.10.1.1 | Integer32 (1..2) | read-only | current |
| integraWradioRangeDescr OBJECT-TYPE 'Minimal' and 'maximal' labels | 1.3.6.1.4.1.7571.100.1.1.7.2.2.10.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraWradioRangeTxPower OBJECT-TYPE Output power ranges for integraWradio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.2.2.10.1.3 | Integer32 | read-only | current |
| integraWradioRangeTxFrequency OBJECT-TYPE Frequency ranges for integraWradio transmitter | 1.3.6.1.4.1.7571.100.1.1.7.2.2.10.1.4 | Integer32 | read-only | current |
| integraWradioPLL OBJECT-TYPE PLL state of local-oscillator generator | 1.3.6.1.4.1.7571.100.1.1.7.2.2.11 | INTEGER {error(1), ok(2)} | read-only | current |
| integraWradioRxLevelState OBJECT-TYPE Received signal level state | 1.3.6.1.4.1.7571.100.1.1.7.2.2.12 | INTEGER {ok(1), low(2), high(3), error(4)} | read-only | current |
| integraWmodem OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.3 | |||
| integraWmodemAcquireStatus OBJECT-TYPE This is the current status of modem data acquire when queried modem status. For detailed info use modemAcquireLastStatusDetails. | 1.3.6.1.4.1.7571.100.1.1.7.2.3.1 | INTEGER {acquireInProgress(1), acquireLocked(2), acquireFailed(3)} | read-only | current |
| integraWmodemMse OBJECT-TYPE Current MSE value (floating point value multiplied by 10) | 1.3.6.1.4.1.7571.100.1.1.7.2.3.2 | Integer32 | read-only | current |
| integraWmodemFecLoad OBJECT-TYPE Decoder stress or FEC load value (floating point in textual representation) | 1.3.6.1.4.1.7571.100.1.1.7.2.3.3 | DisplayString | read-only | current |
| integraWmodemSyncLoss OBJECT-TYPE Modem synchronization status | 1.3.6.1.4.1.7571.100.1.1.7.2.3.4 | INTEGER {locked(1), unlocked(2), unknown(3)} | read-only | current |
| integraWmodemBandwidth OBJECT-TYPE Signal bandwidth | 1.3.6.1.4.1.7571.100.1.1.7.2.3.6 | Integer32 | read-only | current |
| integraWmodemModulation OBJECT-TYPE Modulation (preferred) | 1.3.6.1.4.1.7571.100.1.1.7.2.3.7 | DisplayString | read-only | current |
| integraWmodemRxModulation OBJECT-TYPE Current (actual) Rx Modulation | 1.3.6.1.4.1.7571.100.1.1.7.2.3.8 | DisplayString | read-only | current |
| integraWmodemTxModulation OBJECT-TYPE Current (actual) Tx Modulation | 1.3.6.1.4.1.7571.100.1.1.7.2.3.9 | DisplayString | read-only | current |
| integraWmodemRxCapacity OBJECT-TYPE Rx ethernet capacity in kilobits per second | 1.3.6.1.4.1.7571.100.1.1.7.2.3.10 | Integer32 | read-only | current |
| integraWmodemTxCapacity OBJECT-TYPE Tx ethernet capacity in kilobits per second | 1.3.6.1.4.1.7571.100.1.1.7.2.3.11 | Integer32 | read-only | current |
| integraWmodemAcmEngine OBJECT-TYPE ACM engine status | 1.3.6.1.4.1.7571.100.1.1.7.2.3.12 | INTEGER {enabled(1), disabled(2), error(3)} | read-only | current |
| integraWmodemSignalQuality OBJECT-TYPE Modem signal quality in % | 1.3.6.1.4.1.7571.100.1.1.7.2.3.14 | Integer32 | read-only | current |
| integraWsystem OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.4 | |||
| integraWsysCPUtemperature OBJECT-TYPE System CPU temperature *10 Celsius | 1.3.6.1.4.1.7571.100.1.1.7.2.4.2 | Integer32 | read-only | current |
| integraWsysLicenseExpire OBJECT-TYPE License expires after number of seconds. In the case of -1, check licenseGenStatus status | 1.3.6.1.4.1.7571.100.1.1.7.2.4.3 | Gauge32 | read-only | current |
| integraWsysLicenseGenStatus OBJECT-TYPE License General status. | 1.3.6.1.4.1.7571.100.1.1.7.2.4.4 | INTEGER {ok(1), expired(2), unknown(3), unlimitedTime(4)} | read-only | current |
| integraWsysPSUvoltage OBJECT-TYPE Power voltage in mV | 1.3.6.1.4.1.7571.100.1.1.7.2.4.5 | Integer32 | read-only | current |
| integraWsysPSUcurrent OBJECT-TYPE Power current in mA | 1.3.6.1.4.1.7571.100.1.1.7.2.4.6 | Integer32 | read-only | current |
| integraWsysPSUpower OBJECT-TYPE Power consumption in mW | 1.3.6.1.4.1.7571.100.1.1.7.2.4.7 | Integer32 | read-only | current |
| integraWsysBoardTemperature OBJECT-TYPE System temperature *10 Celsius | 1.3.6.1.4.1.7571.100.1.1.7.2.4.8 | Integer32 | read-only | current |
| integraWsysFreeMemory OBJECT-TYPE System free memory *10 % | 1.3.6.1.4.1.7571.100.1.1.7.2.4.9 | Integer32 | read-only | current |
| integraWsysCPUidle OBJECT-TYPE System CPU idle *10 % | 1.3.6.1.4.1.7571.100.1.1.7.2.4.10 | Integer32 | read-only | current |
| integraWethernet OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.5 | |||
| integraWifStatusTable OBJECT-TYPE Network interface port status data. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1 | not-accessible | current | |
| integraWifPortEntry OBJECT-TYPE An entry containing network physical port status info. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1 | not-accessible | current | |
| integraWifPortStatIndex OBJECT-TYPE A unique value, greater than zero, for each physical network interface. It is recommended that values are assigned contiguously starting from 1. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.1 | Integer32 (1..4) | read-only | current |
| integraWifPortStatDescr OBJECT-TYPE Physical network interface description. LAN1 is electrical, LAN2 and LAN3 are SFP and WAN is radio port. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraWifPortType OBJECT-TYPE The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.3 | IANAifType | read-only | current |
| integraWifPortMtu OBJECT-TYPE Maximum transmission unit value in bytes. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.4 | Integer32 | read-only | current |
| integraWifPortSpeed OBJECT-TYPE Link speed in bits per second. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.5 | Gauge32 | read-only | current |
| integraWifPortPhysAddress OBJECT-TYPE The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.6 | PhysAddress | read-only | current |
| integraWifPortAdminStatus OBJECT-TYPE Desired state of network interfaces. Interfaces can be enabled(1), disabled(2), unknown(3) (no info received). | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.7 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | current |
| integraWifPortOperStatus OBJECT-TYPE Actual state of interfaces. Link can be up(1), down(2) or in unknown(3) state. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.8 | INTEGER {up(1), down(2), unknown(3)} | read-only | current |
| integraWifPortLastChange OBJECT-TYPE This parameter value is always 0 at the moment. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.9 | TimeTicks | read-only | current |
| integraWifPortAutoneg OBJECT-TYPE Auto-negotiation status. Unknown means no info was received. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.10 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | current |
| integraWifPortDuplex OBJECT-TYPE Duplex status for the interface. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.11 | INTEGER {full(1), half(2), unknown(3)} | read-only | current |
| integraWifPortSyncEthActive OBJECT-TYPE Synchronous Ethernet status. Can be active(1) or inactive(0). | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.12 | INTEGER {off(0), on(1)} | read-only | current |
| integraWifPortSyncEthPrio OBJECT-TYPE Synchronous Ethernet priority. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.13 | Integer32 | read-only | current |
| integraWifPortFlowControl OBJECT-TYPE Flow control status. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.1.1.14 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | current |
| integraWifStatisticsTable OBJECT-TYPE Network interface port statistics data. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2 | not-accessible | current | |
| integraWifPortStcEntry OBJECT-TYPE An entry containing network physical port statistics counter data. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1 | not-accessible | current | |
| integraWifPortStcIndex OBJECT-TYPE A unique value, greater than zero, for each physical network interface. It is recommended that values are assigned contiguously starting from 1. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.1 | Integer32 (1..5) | read-only | current |
| integraWifPortStcDescr OBJECT-TYPE Physical network interface description. LAN1 is electrical, LAN2 and LAN3 are SFP, WAN is radio port and MNG is internal management interface. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| integraWifTimePassed OBJECT-TYPE Statistics collection time. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.3 | TimeTicks | read-only | current |
| integraWrxDetected OBJECT-TYPE Detected ingoing packets counter. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.4 | Counter64 | read-only | current |
| integraWrxDropped OBJECT-TYPE Dropped ingoing packets counter. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.5 | Counter64 | read-only | current |
| integraWtxDetected OBJECT-TYPE Detected outgoing packets counter. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.6 | Counter64 | read-only | current |
| integraWtxDropped OBJECT-TYPE Dropped outgoing packets counter. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.7 | Counter64 | read-only | current |
| integraWrxBytes OBJECT-TYPE Ingoing bytes counter. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.8 | Counter64 | read-only | current |
| integraWtxBytes OBJECT-TYPE Outgoing bytes counter. | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.9 | Counter64 | read-only | current |
| integraWrx64Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.10 | Counter64 | read-only | current |
| integraWrx65to127Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.11 | Counter64 | read-only | current |
| integraWrx128to255Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.12 | Counter64 | read-only | current |
| integraWrx256to511Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.13 | Counter64 | read-only | current |
| integraWrx512to1023Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.14 | Counter64 | read-only | current |
| integraWrx1024toMaxFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.15 | Counter64 | read-only | current |
| integraWrxUsizeFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.16 | Counter64 | read-only | current |
| integraWrxOsizeFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.17 | Counter64 | read-only | current |
| integraWtx64Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.18 | Counter64 | read-only | current |
| integraWtx65to127Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.19 | Counter64 | read-only | current |
| integraWtx128to255Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.20 | Counter64 | read-only | current |
| integraWtx256to511Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.21 | Counter64 | read-only | current |
| integraWtx512to1023Frames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.22 | Counter64 | read-only | current |
| integraWtx1024toMaxFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.23 | Counter64 | read-only | current |
| integraWtxUsizeFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.24 | Counter64 | read-only | current |
| integraWtxOsizeFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.25 | Counter64 | read-only | current |
| integraWrxGoodFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.26 | Counter64 | read-only | current |
| integraWrxErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.27 | Counter64 | read-only | current |
| integraWrxFifoErr OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.28 | Counter64 | read-only | current |
| integraWrxCRCErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.29 | Counter64 | read-only | current |
| integraWrxBcastFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.30 | Counter64 | read-only | current |
| integraWrxMcastFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.31 | Counter64 | read-only | current |
| integraWrxCntrlFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.32 | Counter64 | read-only | current |
| integraWrxLenErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.33 | Counter64 | read-only | current |
| integraWrxVlanFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.34 | Counter64 | read-only | current |
| integraWrxPauseFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.35 | Counter64 | read-only | current |
| integraWrxOpErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.36 | Counter64 | read-only | current |
| integraWrxFrameErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.37 | Counter64 | read-only | current |
| integraWtxGoodFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.38 | Counter64 | read-only | current |
| integraWtxErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.39 | Counter64 | read-only | current |
| integraWtxFifoErr OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.40 | Counter64 | read-only | current |
| integraWtxBcastFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.41 | Counter64 | read-only | current |
| integraWtxMcastFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.42 | Counter64 | read-only | current |
| integraWtxUrunErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.43 | Counter64 | read-only | current |
| integraWtxCntrlFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.44 | Counter64 | read-only | current |
| integraWtxVlanFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.45 | Counter64 | read-only | current |
| integraWtxPauseFrames OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.46 | Counter64 | read-only | current |
| integraWtxSingleCollisions OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.47 | Counter64 | read-only | current |
| integraWtxMultiCollisions OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.48 | Counter64 | read-only | current |
| integraWtxDeferred OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.49 | Counter64 | read-only | current |
| integraWtxLateCollisions OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.50 | Counter64 | read-only | current |
| integraWtxExcessCollisions OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.51 | Counter64 | read-only | current |
| integraWtxExcessDeferral OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.52 | Counter64 | read-only | current |
| integraWtxAlignErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.53 | Counter64 | read-only | current |
| integraWtxCarrierErrors OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.54 | Counter64 | read-only | current |
| integraWtxCollisions OBJECT-TYPE | 1.3.6.1.4.1.7571.100.1.1.7.2.5.2.1.55 | Counter64 | read-only | current |
| integraWexecuteConfig OBJECT-TYPE This object can only be set to 1. It initiates new running configuration applying using values, that have been set before. Setting it when no new changes are available will do nothing and return an error. GET will return 0 if there were no errors, while executing configuration or will return a bitmask, that shows which SET requests have failed. Those failed requests will be shown bit wise from LSB as follows: BIT0 radioTxMuteDuration BIT1 radioTxFrequency BIT2 radioTxPower | 1.3.6.1.4.1.7571.100.1.1.7.2.6 | INTEGER {execute(1)} | read-write | current |
| integraWneedStore OBJECT-TYPE This object shows if there is unsaved, but executed (running) configuration. Unsaved changes will be lost after device reboot. Unsaved entities are shown bit wise, starting from LSB as follows: BIT0 Aggregation BIT1 Event log BIT2 Modem BIT3 Network BIT4 Performance BIT5 Radio BIT6 SNMP BIT7 Synchronous Ethernet BIT8 System | 1.3.6.1.4.1.7571.100.1.1.7.2.7 | INTEGER {no(0)} | read-only | current |
| integraWstoreConfig OBJECT-TYPE This object can only be set to 1. It initiates saving of running configuration. It will only work if there are unsaved, but executed (running) changes (configuration). Setting it when no new running configuration is available will do nothing and return an error. | 1.3.6.1.4.1.7571.100.1.1.7.2.8 | INTEGER {store(1)} | read-write | current |
| integraWnetCfg OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.9 | |||
| integraWnetCfgIPaddress OBJECT-TYPE Local IP address | 1.3.6.1.4.1.7571.100.1.1.7.2.9.1 | IpAddress | read-write | current |
| integraWnetCfgIPmask OBJECT-TYPE Local IP mask | 1.3.6.1.4.1.7571.100.1.1.7.2.9.2 | IpAddress | read-write | current |
| integraWnetCfgIPgateway OBJECT-TYPE IP gateway Send '0' or '255.255.255.255' to clear. | 1.3.6.1.4.1.7571.100.1.1.7.2.9.3 | IpAddress | read-write | current |
| integraWnetCfgRemoteIPaddress OBJECT-TYPE Remote IP address | 1.3.6.1.4.1.7571.100.1.1.7.2.9.4 | IpAddress | read-only | current |
| integraWConformance OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.10 | |||
| integraWCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.10.1 | |||
| integraWGroups OBJECT-IDENTITY | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| integraWCompliance MODULE-COMPLIANCE The compliance statement for SNMP engine which implements the SAF Tehnika Integra-W device. | 1.3.6.1.4.1.7571.100.1.1.7.2.10.1.1 | current |
| integraWMiscGroup OBJECT-GROUP misc data | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2.1 | current |
| integraWRadioGroup OBJECT-GROUP Radio group. | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2.2 | current |
| integraWModemGroup OBJECT-GROUP Modem group. | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2.3 | current |
| integraWSystemGroup OBJECT-GROUP System group. | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2.4 | current |
| integraWEthernetGeneralGroup OBJECT-GROUP A collection to objects, providing info applicable to all network interfaces. | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2.5 | current |
| integraWEthernetMiiPortGroup OBJECT-GROUP A collection of objects, providing info applicable only to MII group interfaces. | 1.3.6.1.4.1.7571.100.1.1.7.2.10.2.6 | current |