MIBs Depot

S5-ETH-REDUNDANT-LINKS-MIB

Registered at
1.3.6.1.4.1.45.1.6.6.1.2
1.3.6.1.4.1.45.1.6.6.1.99
Last updated
2004-11-03 00:00
Organization
Nortel Networks
Revisions
2004-11-03 00:00, 2004-07-20 00:00
Namespace
nortel
Source file
S5-ETH-REDUNDANT-LINKS-MIB
Digest
sha256:0af48219bbfd01142c0df31a08d3e36a2bfebc6867a2eaf7a87053730d2a738e

Description

5000 Ethernet Redundant Links MIB Copyright 1993-2004 Nortel Networks, Inc. All rights reserved. This Nortel Networks SNMP Management Information Base Specification (Specification) embodies Nortel Networks' confidential and proprietary intellectual property. Nortel Networks retains all title and ownership in the Specification, including any revisions. This Specification is supplied 'AS IS,' and Nortel Networks makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.

Contact

Nortel Networks

Imports

FromSymbols
S5-ETHERNET-MIBs5EnCfg
S5-TCS-MIBTimeIntervalSec
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

S5-ETH-REDUNDANT-LINKS-MIB
S5-ETHERNET-MIB
S5-ROOT-MIB
S5-TCS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC
SYNOPTICS-ROOT-MIB

Objects

NameOIDSyntaxAccessStatus
s5EnRedun
OBJECT-IDENTITY
1.3.6.1.4.1.45.1.6.6.1.2
s5EnRedPortTable
OBJECT-TYPE
A table with redundancy status and control for each redundancy-capable port in the chassis. The number of entries is determined by the number of redundancy-capable ports in the chassis. The ports appearing in this table can be divided into two categories: Those with remote fault signaling capability and those without. The latter kind depends on the port link status to provide the required redundancy. Ports that are not capable of supporting redundancy do not have an entry in this table.
1.3.6.1.4.1.45.1.6.6.1.2.1not-accessiblecurrent
s5EnRedPortEntry
OBJECT-TYPE
A row in the table of redundancy status and control for each redundancy-capable port in the chassis. Entries in the table cannot be created or deleted via SNMP.
1.3.6.1.4.1.45.1.6.6.1.2.1.1not-accessiblecurrent
s5EnRedPortBrdIndx
OBJECT-TYPE
The index of the slot containing the board on which the port is located.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.1INTEGER (1..255)read-onlycurrent
s5EnRedPortPortIndx
OBJECT-TYPE
The index of the port on the board.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.2INTEGER (1..255)read-onlycurrent
s5EnRedPortCapability
OBJECT-TYPE
The redundancy capability of the port: hwRedOnly(1).....hardware redundancy only. swRedOnly(2).....software redundacy only. hwAndSwRed(3)....both hardware and software redundancy. A value of hwRedOnly(1) or hwAndSwRed(3) means that the port is capable of being configured into a hardware-redundant pair. In this case, the identity of the potential redundant companion is given by the objects s5EnRedPortCompanionBrdNum and s5EnRedPortCompanionPortNum. A value of swRedOnly(2) or hwAndSwRed(3) means that the port is capable of being configured into a software-redundant pair.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.3INTEGER {hwRedOnly(1), swRedOnly(2), hwAndSwRed(3)}read-onlycurrent
s5EnRedPortRedundMode
OBJECT-TYPE
The redundancy mode of the port. The values when written change the redundancy mode, and when read report the redundancy mode: standalone(1)..the port is not in any redundant pair. hwActive(2)....the port is the active companion in a hardware-redundant pair. hwStandby(3)...the port is the standby companion in a hardware-redundant pair. swActive(4)....the port is the active companion in a software-redundant pair. swStandby(5)...the port is the standby companion in a software-redundant pair. The values that can be written, which change the redundancy mode, are: standalone(1)...causes the redundant pair to be broken up. hwActive(2).....if the previous value was hwStandby(3), this value will cause the port to become the active port in the hardware-redundant pair, resulting in a switchover. hwStandby(3)....if the previous value was hwActive(2), this value will cause the port to become the standby port in the hardware-redundant pair, resulting in a switchover. swActive(4).....if the previous value was swStandby(5), this value will cause the port to become the active port in the software-redundant pair, resulting in a switchover. swStandby(5)....if the previous value was swActive(4), this value will cause the port to become the standby port in the software-redundant pair, resulting in a switchover. To create a hardware-redundant pair, change this object to hwActive(2) or hwStandby(3). To create a software-redundant pair, change this object to swActive(4) or swStandby(5). The same SNMP SET PDU must also write to objects s5EnRedPortCompanionBrdNum and s5EnRedPortCompanionPortNum.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.4INTEGER {standAlone(1), hwActive(2), hwStandby(3), swActive(4), swStandby(5)}read-writecurrent
s5EnRedPortOperStatus
OBJECT-TYPE
The redundancy status of the port. The values are: other(1).............none of the following. ok(2)...................no fault localFault(3)....the local port has sensed a fault condition. remoteFault(4)...the remote port has sensed a fault condition and has signaled the local port accordingly. Either a localFault(3) or remoteFault(4) condition should cause a healthy redundant port pair to switchover. If the port does not belong to a redundant pair, a value of other(1) is returned. Note: If the redundant link consists of ports without remote fault capability, the value remoteFault(4) will not be reported and the value localFault(3) implies that link is off.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.5INTEGER {other(1), ok(2), localFault(3), remoteFault(4)}read-onlycurrent
s5EnRedPortRemoteOperStatus
OBJECT-TYPE
This object reflects the real time status of the received data from the remote port. The values are: snpxFLRemFltCpblPortUp(1)....10BASE-FL signaling, plus capable of SynOptics proprietary remote fault signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). snpxFLFBRemFltCpblPortUp(2)..10BASE-FL signaling, plus capable of SynOptics proprietary remote fault signaling and 10BASE-FB signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). tenBaseTFLPortUp(3)...........regular idle 10BASE-T or 10BASE-FL signaling, and is incapable of remote fault signaling. tenBaseFBPortUp(4)...........10BASE-FB synchronous signaling. A remote fault on such a port is indicated by tenBaseFBPortFault(6). snpxRemFltCpblPortFault(5)...SynOptics proprietary remote fault signaling. tenBaseFBPortFault(6)........10BASE-FB remote fault signaling. unknown(7)...................none of the above. A value of snpxFLRemFltCpblPortUp(1) indicates that the remote port is using 10BASE-FL signaling, and is capable of SynOptics proprietary idle and remote fault signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). A value of snpxFLFBRemFltCpblPortUp(2) indicates that the remote port is using 10BASE-FL signaling, and is capable of SynOptics proprietary idle and remote fault signaling, and is also capable of synchronous signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). A value of tenBaseFLPortUp(3) indicates that the remote port uses regular idle 10BASE-FL signaling, and is incapable of remote fault signaling. A value of tenBaseFBPortUp(4) indicates that the remote port uses 10BASE-FB synchronous signaling. A remote fault on such a port is indicated by tenBaseFBPortFault(6).
1.3.6.1.4.1.45.1.6.6.1.2.1.1.6INTEGER {snpxFLRemFltCpblPortUp(1), snpxFLFBRemFltCpblPortUp(2), tenBaseTFLPortUp(3), tenBaseFBPortUp(4), snpxRemFltCpblPortFault(5), tenBaseFBPortFault(6), unknown(7)}read-onlycurrent
s5EnRedPortRemFltSelectMode
OBJECT-TYPE
This mode specifies the set of local fault events which will cause a switchover. The values are: synoptics(1)..The SynOptics Tx Remote Fault events consist of auto-partition and NM (network management) partition events in addition to the standard events. standard(2)...The standard events are link-off for all ports, and low light, jabber, Rx invalid idle, Tx dark, and Tx remote fault (for diagnostics) for ports with transmit remote fault capability.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.7INTEGER {synoptics(1), standard(2)}read-writecurrent
s5EnRedPortTxMode
OBJECT-TYPE
The Transmit Fiber Mode, which determines the port transmit idle. The values are: autoCfg(1)...The port will auto configure based upon the received idle. fl(2)........The port is configured in FL mode. fb(3)........The port is configured in FB mode. other(4).....None of the above. The port is not a fiber port. The value other(4) is read-only.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.8INTEGER {autoCfg(1), fl(2), fb(3), other(4)}read-writecurrent
s5EnRedPortFaults
OBJECT-TYPE
A count of local or remote faults on this port. This counter increments on a transition between the fault and no-fault states.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.9Counter32read-onlycurrent
s5EnRedPortModeChanges
OBJECT-TYPE
A count of the number of times this port has transitioned from standby mode to non-standby mode (includes active mode and standalone mode), or vice versa.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.10Counter32read-onlycurrent
s5EnRedPortCompanionBrdNum
OBJECT-TYPE
The index of the slot containing the board of the other port in the redundant pair. If the port (whose slot-port identity is given by the instance) is hardware-redundant capable, this object has the value of the slot number of the (potential) redundant companion, even if the port is in standalone mode. This allows the network manager to determine the identity of the potential companion, which is fixed by the hardware of the board. Changing this object is permitted only when creating a software-redundant pair.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.11INTEGER (1..255)read-writecurrent
s5EnRedPortCompanionPortNum
OBJECT-TYPE
The index of the other port in the redundant pair. If the port (whose slot-port identity is given by the instance) is hardware-redundant capable, this object has the value of the port number of the (potential) redundant companion, even if the port is in standalone mode. This allows the network manager to determine the identity of the potential companion, which is fixed by the hardware of the board. Changing this object is permitted only when creating a software-redundant pair.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.12INTEGER (1..255)read-writecurrent
s5EnRedPortSwitchoverStatus
OBJECT-TYPE
The switchover status of the port (and its companion). The following values can be written: timedSwitchover(2)...cause a timed switchover (see value of s5EnRedPortSwitchoverTime) The following values reflect the switchover status of the redundant port pair: other(1)..............not undergoing switchover timedSwitchover(2)....port is undergoing timed switchover (see value of s5EnRedPortSwitchoverTime). On GETs with switchover status of timedSwitchover(2), if the time remaining before the completion of the switchover and reversal is available, it will be reported in object s5EnRedPortSwitchoverTime as a positive value If not available, the value of s5EnRedSwitchoverTime will be zero. When changing a port to timedSwitchover(2), the SET request must also contain the value for object s5EnRedSwitchoverTime.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.13INTEGER {other(1), timedSwitchover(2)}read-writecurrent
s5EnRedPortSwitchoverTime
OBJECT-TYPE
The length of time between switching over a redundant port pair and switching back, when a timed switchover is done to the port. This object can only be written in the same request that sets s5EnRedPortSwitchoverStatus to timedSwitchover(2). Afterwards, it indicates the amount of time left before the timed switchover is completed, at which time another switchover occurs and s5EnRedSwitchoverStatus is changed to other(1). This object has the value of zero if the port is not undergoing a timed switchover, or if the amount of time is not available.
1.3.6.1.4.1.45.1.6.6.1.2.1.1.14TimeIntervalSec (0..65535)read-writecurrent
s5EnRedLastChg
OBJECT-TYPE
The value of sysUpTime when the last change in the redundant ports table was observed by the agent.
1.3.6.1.4.1.45.1.6.6.1.2.2TimeTicksread-onlycurrent