RS-XX9-MTX-MIB
- Registered at
- 1.3.6.1.4.1.2566.127.1.2.216.4.01.3.6.1.4.1.2566.127.1.2.216.4.11.3.6.1.4.1.2566.127.1.2.216.4.21.3.6.1.4.1.2566.149.1.216.4
- Last updated
- 2016-03-03 11:00
- Organization
- Rohde&Schwarz GmbH & Co. KG
- Revisions
- 2016-03-03 11:00, 2016-02-03 09:00, 2015-10-20 12:00, 2014-12-22 16:00, 2014-10-07 14:00, 2014-03-03 16:00, 2014-02-06 14:00, 2012-10-04 08:00
- Namespace
- rs
- Source file
RS-XX9-MTX-MIB- Digest
sha256:2f853e69d6e91ee843d9b7c615ada0da7ab0c303120a6588d89b57f693904725
Description
This MIB defines system control specific objects of XX9000 transmitting systems from Rohde & Schwarz. Use this MIB for Multi-TX or N+1 system control. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB. - RS-XX9-TC-MIB - mandatory for this MIB. - RS-XX9-SMI-MIB - mandatory for this MIB.
Contact
Rohde & Schwarz GmbH & Co. KG Broadcasting Division Muehldorfstrasse 15 81671 Munich Germany customersupport@rohde-schwarz.com
Imports
| From | Symbols |
|---|---|
| RS-XX9-COMMON-MIB | commonNotificationAlarmClass |
| RS-XX9-SMI-MIB | rsXx9MTx, rsXx9MibModule |
| RS-XX9-TC-MIB | IndexTransmitter, NotificationMask, NotificationPriority, NotificationState, SwitchOnOff, Trigger |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ENTITY-MIB IANA-ENTITY-MIB INET-ADDRESS-MIB RS-COMMON-MIB RS-XX9-COMMON-MIB RS-XX9-MTX-MIB RS-XX9-SMI-MIB RS-XX9-TC-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rsXx9MtxNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.0 | |||
| rsXx9MtxObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1 | |||
| mtxNotificationTable OBJECT-TYPE Objects from the mtxNotificationTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1 | not-accessible | current | |
| mtxNotificationEntry OBJECT-TYPE An entry in the mtxNotificationTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1.1 | not-accessible | current | |
| mtxNotificationIdx OBJECT-TYPE The notification number as below rsXx9MtxNotifications. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1.1.1 | Unsigned32 (1..6 | 100..101) | not-accessible | current |
| mtxNotificationName OBJECT-TYPE The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9MtxNotifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1.1.2 | INTEGER {mtxNp1AutomaticSummary(1), mtxNp1AutomaticReady(2), mtxNp1AutomaticRfSwitch(3), mtxNp1AutomaticInputChannel(4), mtxNp1AutomaticChangeOver(5), mtxLocal(6), mtxMultiTxSummary(100), mtxMultiTxRfSwitch(101)} | read-only | current |
| mtxNotificationMask OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1.1.3 | NotificationMask | read-write | current |
| mtxNotificationPriority OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1.1.4 | NotificationPriority | read-write | current |
| mtxNotificationState OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.1.1.5 | NotificationState | read-only | current |
| mtxSystemControl OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.2 | |||
| mtxNplus1 OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3 | |||
| nplus1AutomaticStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1 | |||
| np1AutomaticLoadedTx OBJECT-TYPE If a switchover operation has taken place, shows which program of an A transmitter the B transmitter has taken over. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1.1 | INTEGER {txA1(1), txA2(2), txA3(3), txA4(4), txA5(5), txA6(6), txA7(7), txA8(8), none(9), undefined(10)} | read-only | current |
| np1AutomaticReserveRf OBJECT-TYPE indicates a warning/fault if RF power of reserve transmitter falls below the adjusted warning/fault limit. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1.2 | NotificationState | read-only | current |
| np1AutoSwitchesTable OBJECT-TYPE Table with data about RfSwitches in an nplus1 system. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1.100 | not-accessible | current | |
| np1AutoSwitchesEntry OBJECT-TYPE An entry in the np1AutoSwitchesTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1.100.1 | not-accessible | current | |
| np1AutoSwitchIdx OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1.100.1.1 | Integer32 (1..8) | read-only | current |
| np1AutoSwitchPos OBJECT-TYPE The position of the rfSwitch. Usually, SwitchX is responsible for switching between antenna and dummyload for TransmitterX. Usually, pos1(1) means, that the transmitter is switched to antenna and pos2(2) means, that the transmitter is switched to dummyload. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.1.100.1.2 | INTEGER {unknown(0), pos1(1), pos2(2)} | read-only | current |
| nplus1AutomaticConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2 | |||
| np1AutomaticOperationMode OBJECT-TYPE Activates the n+1 automatic function. If the n+1 automatic function is on(1), a fault within an A transmitter causes a switchover and the program of the A transmitter is taken over by the standby B transmitter. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.1 | SwitchOnOff | read-write | current |
| np1AutoSwitchoverGuardTime OBJECT-TYPE Checkout time which must pass before a program transmitter with sum fault is replaced by the standby transmitter. A long Guard Time suppresses switchover operations caused by brief faults, but also reduces the availability of the program. A guard time less than two seconds might lead to an unnecessary switchover in case of a phase break of amplifiers. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.2 | Unsigned32 (1..60) | read-write | current |
| np1AutoSwitchMode OBJECT-TYPE Defines the switching behavior of the N+1 automatic function. severalTimes(1) - Following a switchover operation, the system can switch back to the A transmitter automatically when the A transmitter no longer signals a fault but the B transmitter indicates a fault. singleShot(2) - Switchover of an A transmitter to the B transmitter can occur once only. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.3 | INTEGER {severalTimes(1), singleShot(2)} | read-write | current |
| np1AutoProgramPreset OBJECT-TYPE Loads the program-specific settings of an A transmitter to the B transmitter. unknownPreset(0) can not be commanded. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.4 | INTEGER {unknownPreset(0), txA1(1), txA2(2), txA3(3), txA4(4), txA5(5), txA6(6), txA7(7), txA8(8)} | read-write | current |
| np1AutoInputPreset OBJECT-TYPE Determines the preconfigured transport stream for TX-B via the TS distributor. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.5 | INTEGER {channel1(1), channel2(2), channel3(3), channel4(4), channel5(5), channel6(6), channel7(7), channel8(8), channel9(9)} | read-write | current |
| np1AutoPriorityEnable OBJECT-TYPE Activaes the priority-controlled n+1 switchover function. If priority control is active, a further switchover of a program with higher priority can take place following the switchover of a low-priority program. In this case, the low-priority program is switched back to its defective A transmitter. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.7 | SwitchOnOff | read-write | current |
| np1AutoToLoad OBJECT-TYPE Performs a manual switchover. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.8 | IndexTransmitter | read-write | current |
| np1AutoReserveOperationMode OBJECT-TYPE Switches reserve transmitter on or off. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.9 | SwitchOnOff | read-write | current |
| np1AutoProgramTable OBJECT-TYPE Program specific configuration. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10 | not-accessible | current | |
| np1AutoProgramEntry OBJECT-TYPE An entry in the np1AutoProgramTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10.1 | not-accessible | current | |
| np1AutoProgramIdx OBJECT-TYPE Program index - coincides with TxA index. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10.1.1 | Unsigned32 (1..8) | not-accessible | current |
| np1AutoProgramOperationMode OBJECT-TYPE Switches program transmitter on or off. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10.1.2 | SwitchOnOff | read-write | current |
| np1AutoProgramPriority OBJECT-TYPE Priority of the respective program. 1 is the highest priority and 8 is the lowest priority. The specified program number corresponds to the number of the A transmitter assigned in each case. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10.1.3 | Unsigned32 (1..8) | read-write | current |
| np1AutoProgramChangeover OBJECT-TYPE Used to activate the N+1 automatic function individually for each A transmitter. This setting can be used to remove A transmitters from the N+1 automatic function. The same effect can be achieved by configuring the respective A transmitter for local operation. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10.1.4 | SwitchOnOff | read-write | current |
| np1AutoProgramRf OBJECT-TYPE indicates a warning/fault if RF power of program transmitter falls below the adjusted warning/fault limit. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.10.1.5 | NotificationState | read-only | current |
| np1AutoReset OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.11 | Trigger | read-write | current |
| np1AutoWhenTxBLocal OBJECT-TYPE TxB and n+1 automatic control are located in the same device and share one local/remote button. By default the n+1 automatic shall be disabled when TxB is set to local operation. To test the n+1 automatic using the local display the n+1 automatic can be activated even in local operation mode. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.2.12 | INTEGER {automaticAvailable(1), automaticNotAvailable(2)} | read-write | current |
| np1AutoProgramNotificationTable OBJECT-TYPE The context information/configuration for the program status notifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3 | not-accessible | current | |
| np1AutoProgramNotificationEntry OBJECT-TYPE An entry in the np1AutoProgramNotificationTable | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1 | not-accessible | current | |
| np1AutoProgramNotificationProgramIdx OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1.1 | Unsigned32 (1..8) | read-only | current |
| np1AutoProgramNotificationIdx OBJECT-TYPE The notification number as below rsXx9nplus1AutomaticProgramNotifications. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1.2 | Unsigned32 (7) | read-only | current |
| np1AutoProgramNotificationName OBJECT-TYPE The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9MtxNotifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1.3 | INTEGER {mtxNp1AutomaticProgramRf(7)} | read-only | current |
| np1AutoProgramNotificationMask OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1.4 | NotificationMask | read-write | current |
| np1AutoProgramNotificationPriority OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1.5 | NotificationPriority | read-write | current |
| np1AutoProgramNotificationState OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.3.3.1.6 | NotificationState | read-only | current |
| mtxMultiTx OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4 | |||
| multiTxTransmitterTable OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.1 | not-accessible | current | |
| multiTxTransmitterEntry OBJECT-TYPE An entry in the multiTxTransmitterTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.1.1 | not-accessible | current | |
| multiTxTxIdx OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.1.1.1 | IndexTransmitter | not-accessible | current |
| multiTxLoadedOrAntenna OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.1.1.2 | INTEGER {unknown(1), antenna(2), load(3)} | read-write | current |
| multiTxToLoad OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.1.1.3 | Trigger | read-write | current |
| multiTxToAntenna OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.1.1.4 | Trigger | read-write | current |
| multiTxConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.2 | |||
| multiTxReset OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.4.2.1 | Trigger | read-write | current |
| mtxBackupTx OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5 | |||
| btxAutoNotificationTable OBJECT-TYPE Objects from the btxNotificationTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1 | not-accessible | current | |
| btxAutoNotificationEntry OBJECT-TYPE An entry in the btxAutoNotificationTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1 | not-accessible | current | |
| btxAutoNotificationAutomaticIdx OBJECT-TYPE enumerates over all backupTx automatics. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1.1 | INTEGER (1) | not-accessible | current |
| btxAutoNotificationIdx OBJECT-TYPE The notification number as below rsXx9MtxNotifications. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1.2 | Integer32 (200..204) | not-accessible | current |
| btxAutoNotificationName OBJECT-TYPE The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9MtxNotifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1.3 | INTEGER {mtxBackupTxSummary(200), mtxBackupTxReady(201), mtxBackupTxLink(202), mtxBackupTxRfSwitch(203), mtxBackupTxSwitchedOver(204)} | read-only | current |
| btxAutoNotificationMask OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1.4 | NotificationMask | read-write | current |
| btxAutoNotificationPriority OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1.5 | NotificationPriority | read-write | current |
| btxAutoNotificationState OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.1.1.6 | NotificationState | read-only | current |
| btxAutoStatusTable OBJECT-TYPE The status of a backupTx automatic. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.2 | not-accessible | current | |
| btxAutoStatusEntry OBJECT-TYPE An entry in the btxAutoStatusTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.2.1 | not-accessible | current | |
| btxAutoStActiveTx OBJECT-TYPE Indicates which transmitter is connected to the antenna via the rf-switch. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.2.1.1 | INTEGER {undefined(1), txA(2), txB(3)} | read-only | current |
| btxAutoConfigurationTable OBJECT-TYPE The configuration of a backupTx automatic. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3 | not-accessible | current | |
| btxAutoConfigurationEntry OBJECT-TYPE An entry in the btxAutoConfigurationTable. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3.1 | not-accessible | current | |
| btxAutoCfgReset OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3.1.1 | Trigger | read-write | current |
| btxAutoCfgOperationMode OBJECT-TYPE Indicates if the Backup Tx automatic is enabled. If the automatic is enabled, a switchover to a reserve transmitter occurs after a configurable guard time, as soon as the preselected transmitter signals a fault. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3.1.2 | SwitchOnOff | read-write | current |
| btxAutoCfgMode OBJECT-TYPE Indicates how the automatic behaves, when the reserve transmitter signals a fault. - multipleShot(1) after a switch over to the reserve transmitter has happened, a switch over to the preselected transmitter happens, if the preselected transmitter signales no fault. A manual operator action is not necessary. - singleShot(2): after a switch over to the reserve transmitter has happened, the reserve transmit stays active even if the reserve transmitter signals a fault and the preselected transmitter could work without faults. A manual operator action is necessary to re-enable the automatic. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3.1.3 | INTEGER {multipleShot(1), singleShot(2)} | read-write | current |
| btxAutoCfgGuardTime OBJECT-TYPE Indicates how long no a switchover shall be delayed after detecting a fault. By increasing the guard time, switch overs caused by short temporary faults can be avoided. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3.1.4 | Unsigned32 (0..60) | read-write | current |
| btxAutoCfgPreselectTx OBJECT-TYPE Indicates, which transmitter should be primarily used to transmit a program. | 1.3.6.1.4.1.2566.127.1.2.216.4.1.5.3.1.5 | INTEGER {txA(2), txB(3)} | read-write | current |
| rsXx9MtxConformance OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.2 | |||
| rsXx9MtxCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.2.1 | |||
| rsXx9MtxGroups OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| mtxNp1AutomaticSummary NOTIFICATION-TYPE N+1 automatic summary state. Possible values: off(2) fault(3) warning(4) ok(5) Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.4.0.1 | current |
| mtxNp1AutomaticReady NOTIFICATION-TYPE Indicates whether the n+1 automatic is ready. It shows not ready if a changeover occurs and no higher priorized programs are available. Possible values: off(2) - not ready ok(5) - ready Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.4.0.2 | current |
| mtxNp1AutomaticRfSwitch NOTIFICATION-TYPE Indicates a fault if in the event of a switchover one of the RF switches could not be turned correctly or if one of the jumpers has not been positioned correctly on the patch panel (if used). Possible values: off(2) - RF switch ok fault(3) - RF switch faulty Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.4.0.3 | current |
| mtxNp1AutomaticInputChannel NOTIFICATION-TYPE Indicates whether the TS distributor has directed the correct transport stream to the input of transmitter B. Possible values: off(2) - input to TxB is ok fault(3) - TS distributor fails to deliver input to TxB Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.4.0.4 | current |
| mtxNp1AutomaticChangeOver NOTIFICATION-TYPE Possible values: off(2) - warning(4) - a changeover to TxB occured Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.4.0.5 | current |
| mtxLocal NOTIFICATION-TYPE local/remote state of system control. Possible values: off(2) - remote ok(5) - local Notification class: info | 1.3.6.1.4.1.2566.127.1.2.216.4.0.6 | current |
| mtxNp1AutomaticProgramRf NOTIFICATION-TYPE indicates a warning/fault if RF power of program transmitter falls below the adjusted warning/fault limit. | 1.3.6.1.4.1.2566.127.1.2.216.4.0.7 | current |
| mtxMultiTxSummary NOTIFICATION-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.0.100 | current |
| mtxMultiTxRfSwitch NOTIFICATION-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.4.0.101 | current |
| mtxBackupTxSummary NOTIFICATION-TYPE Indicates the overall state of the automatic Possible values: off(2) - the automatic is switched off fault(3) - the automatic cannot operate, e.g. the rf-switch is not connected warning(4) - the automatic signals a warning, e.g. the automatic has switched over ok(5) - the automatic is on and operational | 1.3.6.1.4.1.2566.127.1.2.216.4.0.200 | current |
| mtxBackupTxReady NOTIFICATION-TYPE Indicates whether the automatic is able to switch to the inactive transmitter in case of a fault of the active one. Possible values: off(2) - not ready ok(5) - ready | 1.3.6.1.4.1.2566.127.1.2.216.4.0.201 | current |
| mtxBackupTxLink NOTIFICATION-TYPE Indicates, if an ethernet-connection between txA and txB exists. If the connection fails and the automatic is enabled, the reserve transmitter is switched to the antenna. Possible values: warning(4) - ok(5) - | 1.3.6.1.4.1.2566.127.1.2.216.4.0.202 | current |
| mtxBackupTxRfSwitch NOTIFICATION-TYPE Indicates if the rf-switch is ready. Possible values: undefined(1) - no electrical connection between automatic and rf-switch fault(3) - ok(5) - | 1.3.6.1.4.1.2566.127.1.2.216.4.0.203 | current |
| mtxBackupTxSwitchedOver NOTIFICATION-TYPE Indicates if the current switch position defers from the preselected switch position. possible values: off(2) - switch position is the same as the preselected switch position warning(4) - switch position defers from the preselected switch position. | 1.3.6.1.4.1.2566.127.1.2.216.4.0.204 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| mtxSystemControlCompliance MODULE-COMPLIANCE The compliance statement for XX9000 MTX control. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.1.1 | current |
| mtxNplus1Compliance MODULE-COMPLIANCE The compliance statement for XX9000 N+1 control. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.1.2 | current |
| mtxObjsNotificationTable OBJECT-GROUP common objects for systems. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.1 | current |
| mtxObjsNplus1 OBJECT-GROUP All N+1 objects. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.2 | current |
| mtxNotifyNplus1 NOTIFICATION-GROUP All N+1 notifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.3 | current |
| mtxNotifySystemControl NOTIFICATION-GROUP All MTX notifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.4 | current |
| mtxObsMultiTx OBJECT-GROUP multiTx objects. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.100 | current |
| mtxObjsMultiTxDummyLoads OBJECT-GROUP multiTx with dummyLoads objects. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.101 | current |
| mtxObjsMultiTxDummyLoadSwitches OBJECT-GROUP objects for switches of multiTx with dummyloads. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.102 | current |
| mtxNotifyMultiTx NOTIFICATION-GROUP multiTx notifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.150 | current |
| mtxNotifyMultiTxSwitches NOTIFICATION-GROUP switches of multiTx notifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.151 | current |
| mtxObjsBackupTx OBJECT-GROUP backupTx objects. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.152 | current |
| mtxNotifyBackupTx NOTIFICATION-GROUP backupTx notifications. | 1.3.6.1.4.1.2566.127.1.2.216.4.2.2.153 | current |