RS-XX9-LIQUID-COOLING-MIB
- Registered at
- 1.3.6.1.4.1.2566.127.1.2.216.100.01.3.6.1.4.1.2566.127.1.2.216.100.11.3.6.1.4.1.2566.127.1.2.216.100.21.3.6.1.4.1.2566.149.1.216.100
- Last updated
- 2015-11-30 17:00
- Organization
- Rohde&Schwarz GmbH & Co. KG
- Revisions
- 2015-11-30 17:00, 2015-08-20 15:00, 2015-06-23 12:00, 2015-02-27 15:00, 2014-12-22 16:00, 2013-10-07 12:00, 2013-01-31 13:00, 2012-05-11 08:00, 2012-01-26 08:00
- Namespace
- rs
- Source file
RS-XX9-LIQUID-COOLING-MIB- Digest
sha256:61fd485eb8dfbbb7b72eb1716db4c6089cba2ec3c90b3d616e87ced6056cf782
Description
This MIB defines liquid cooling specific objects of XX9000 transmitting systems from Rohde & Schwarz. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB. - RS-XX9-SMI-MIB - mandatory for this MIB. - RS-XX9-TC-MIB - mandatory for this MIB. - RS-XX9-COMMON-MIB - mandatory for this MIB.
Contact
Rohde & Schwarz GmbH & Co. KG Broadcasting Division Muehldorfstrasse 15 81671 Munich Germany customersupport@rohde-schwarz.com
Imports
| From | Symbols |
|---|---|
| RS-XX9-COMMON-MIB | commonNotificationAlarmClass |
| RS-XX9-SMI-MIB | rsXx9LiquidCooling, rsXx9MibModule |
| RS-XX9-TC-MIB | NotificationMask, NotificationPriority, NotificationState, SwitchOnOff |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ENTITY-MIB IANA-ENTITY-MIB INET-ADDRESS-MIB RS-COMMON-MIB RS-XX9-COMMON-MIB RS-XX9-LIQUID-COOLING-MIB RS-XX9-SMI-MIB RS-XX9-TC-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC UUID-TC-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rsXx9LiquidCoolingNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.0 | |||
| rsXx9LiquidCoolingObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.1 | |||
| lqStatus OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1 | |||
| lqNotificationTable OBJECT-TYPE The context information/configuration for the liquid cooling status notifications. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1 | not-accessible | current | |
| lqNotificationEntry OBJECT-TYPE An entry in the lqNotificationTable. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1 | not-accessible | current | |
| lqNotificationCycleIdx OBJECT-TYPE Liquid cooling cycle index. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.1 | Unsigned32 (1..12) | not-accessible | current |
| lqNotificationIdx OBJECT-TYPE The notification number as below rsXx9LiquidCoolingNotifications. This is a helper column and therefore not-accessible. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.2 | Unsigned32 (1..5) | not-accessible | current |
| lqNotificationName OBJECT-TYPE The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9LiquidCoolingNotifications. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.3 | INTEGER {lqSummary(1), lqFilterSummary(2), lqSensorsSummary(3), lqSiteWarning(4), lqSiteFault(5)} | read-only | current |
| lqNotificationMask OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.4 | NotificationMask | read-write | current |
| lqNotificationPriority OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.5 | NotificationPriority | read-write | current |
| lqNotificationState OBJECT-TYPE See textual convention for details. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.6 | NotificationState | read-only | current |
| lqStateTable OBJECT-TYPE Liquid cooling state information. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2 | not-accessible | current | |
| lqStateEntry OBJECT-TYPE An entry in the lqStateTable. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1 | not-accessible | current | |
| lqStInletTemperature OBJECT-TYPE Temperature of the pouring in coolant. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.2 | Integer32 | read-only | current |
| lqStInletTemperatureSensor OBJECT-TYPE Indicates whether the inlet temperature sensor is working. If a fault is displayed, please check the connection between sensor and cooling interface which is located in TCE900 System Control. fault(3) - sensor fault ok(5) - sensor is working. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.3 | NotificationState | read-only | current |
| lqStInletTemperatureSumState OBJECT-TYPE Indicates whether the inlet temperature of coolant is too high. If this problem is not caused by the ambient air temperature of heat exchangers the pumps and the fans of heat exchanger should be checked and the filter should be cleaned. fault(3) - exceeds fault limit warning(4) - exceeds warning limit ok(5) - is ok | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.4 | NotificationState | read-only | current |
| lqStOutletTemperature OBJECT-TYPE Temperature of coolant before going into heat exchanger. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.5 | Integer32 | read-only | current |
| lqStOutletTemperatureSensor OBJECT-TYPE Indicates the status of the temperature sensor at the outlet of the rack. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.6 | NotificationState | read-only | current |
| lqStOutletTemperatureSumState OBJECT-TYPE Indicates whether the outlet temperature of coolant is too high. If this problem is not caused by the ambient air temperature of heat exchangers the pumps and the fans of heat exchanger should be checked and the filter should be cleaned. The display of this alarm disappears when the outlet temperature is lower than the selected warning limit. off(2) fault(3) - exceeds fault limit warning(4) - exceeds warning limit ok(5) - is ok | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.7 | NotificationState | read-only | current |
| lqStCoolantPressure OBJECT-TYPE Coolant pressure. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.8 | Unsigned32 | read-only | current |
| lqStCoolantPressureSensor OBJECT-TYPE Coolant pressure sensor state. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.9 | NotificationState | read-only | current |
| lqStCoolantPressureSumState OBJECT-TYPE Indicates whether the coolant pressure is too low. If a fault is displayed the cooling equipment should be checked for a leakage and the filter should be cleaned. Possible values: off(2) - fault(3) - sensor fault warning(4) - ok(5) - | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.10 | NotificationState | read-only | current |
| lqStInletTemperatureFaultLimit OBJECT-TYPE If the outlet temperature sensor is defective then an inlet temperature exceeding this value will lead to an error. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.11 | Integer32 | read-only | obsolete |
| lqStInletTemperatureWarningLimit OBJECT-TYPE If the outlet temperature sensor is defective then an inlet temperature exceeding this value will lead to a warning. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.12 | Integer32 | read-only | obsolete |
| lqStCompactPumpDesiredSpeed OBJECT-TYPE Description. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.13 | Unsigned32 (0..100) | read-only | current |
| lqPumpStateTable OBJECT-TYPE pump state information | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3 | not-accessible | current | |
| lqPumpStateEntry OBJECT-TYPE An entry in the lqPumpStateTable. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1 | not-accessible | current | |
| lqPStPumpIdx OBJECT-TYPE pump index | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.2 | Unsigned32 (1..2) | not-accessible | current |
| lqPStCommunicationState OBJECT-TYPE State of communication between TCE and pump. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.3 | NotificationState | read-only | current |
| lqPStSumState OBJECT-TYPE pump summary state | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.4 | NotificationState | read-only | current |
| lqPStMotorBlocked OBJECT-TYPE Indicates whether the pump motor can run freely or is mechanically blocked. To rectify this fault, the pump must be disassembled and checked for foreign objects. off(2) fault(3) - blocked ok(5) | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.5 | NotificationState | read-only | current |
| lqPStOperatingHours OBJECT-TYPE Operating hours of pump. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.6 | Unsigned32 | read-only | current |
| lqPStType OBJECT-TYPE Indicates the used pump type. The displayed type is identical to the type specified on the type plate of the pump. The type 'Magna2: 40-100' should be used for transmitters with up to 6 amplifiers. The type 'Magna2: 32-120' should be used for transmitters with more than 6 amplifiers. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.7 | SnmpAdminString | read-only | current |
| lqPStCurrentFlowRate OBJECT-TYPE current flow rate of pump | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.8 | Unsigned32 | read-only | current |
| lqPStCurrentSpeed OBJECT-TYPE rotational speed of pump motor | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.9 | Unsigned32 | read-only | current |
| lqFanStateTable OBJECT-TYPE fan state table | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4 | not-accessible | current | |
| lqFanStateEntry OBJECT-TYPE An entry in the lqFanStateTable. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1 | not-accessible | current | |
| lqFStFanIdx OBJECT-TYPE fan index | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.1 | Unsigned32 (1..4) | not-accessible | current |
| lqFStCommunicationState OBJECT-TYPE Indicates whether the assigned fan is correctly registered on the fan communication bus. If a fault is displayed the corresponding task to re-register the fans on its communication bus should be started. Possible values: off(2) - fault(3) - not found ok(5) - installed | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.2 | NotificationState | read-only | current |
| lqFStSumState OBJECT-TYPE fan summary state | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.3 | NotificationState | read-only | current |
| lqFStMotorBlocked OBJECT-TYPE Shows whether the fan motor is mechanical blocked. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.4 | NotificationState | read-only | current |
| lqFStOperatingHours OBJECT-TYPE fan operating hours | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.5 | Unsigned32 | read-only | current |
| lqFStSupplyFailure OBJECT-TYPE Shows whether the fan is disconnected from power supply. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.6 | NotificationState | read-only | current |
| lqFStCurrentSpeed OBJECT-TYPE rotational speed of fan motor | 1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.7 | Unsigned32 | read-only | current |
| lqConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2 | |||
| lqConfigTable OBJECT-TYPE Liquid cooling configuration. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1 | not-accessible | current | |
| lqConfigEntry OBJECT-TYPE An entry in the lqConfigTable table. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1 | not-accessible | current | |
| lqCfgCycleIdx OBJECT-TYPE Liquid cooling cycle index. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.1 | Unsigned32 (1..12) | not-accessible | current |
| lqCfgType OBJECT-TYPE coolingRS(1) - XX9 cooling system coolingSite(2) - already existing site cooling coolingRSsmall(3) - small XX9 cooling system cooling8000(4) - legacy XX8000 cooling system | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.2 | INTEGER {coolingRS(1), coolingSite(2), coolingRSsmall(3), cooling8000(4)} | read-write | current |
| lqCfgHeatExchangersPerRack OBJECT-TYPE Number of heat exchangers per rack. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.3 | Unsigned32 (1..2) | read-write | current |
| lqCfgFansPerHeatExchanger OBJECT-TYPE Number of fans per heat exchanger. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.4 | Unsigned32 (1..2) | read-write | current |
| lqCfgCoolantSetPointTemperature OBJECT-TYPE The nominal value of the coolant temperature for fan control. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.5 | Integer32 (20..65) | read-write | current |
| lqCfgCoolantTemperatureFaultLimit OBJECT-TYPE A coolant temperature exceeding this value will lead to an error. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.6 | Integer32 (50..65) | read-write | current |
| lqCfgCoolantTemperatureWarningLimit OBJECT-TYPE A coolant temperature exceeding this value will lead to a warning. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.7 | Integer32 (40..65) | read-write | current |
| lqCfgCoolantPressureFaultLimit OBJECT-TYPE A coolant pressure equal or below this value will lead to an error. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.8 | Unsigned32 (0..40) | read-write | current |
| lqCfgCoolantPressureWarningLimit OBJECT-TYPE A coolant pressure equal or below this value will lead to a warning. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.9 | Unsigned32 (0..40) | read-write | current |
| lqCfgFanMaxSpeed OBJECT-TYPE You can diminish the fan speed for noise reduction. But this may lead to an unwanted increase of coolant temperature. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.10 | Unsigned32 (50..100) | read-write | current |
| lqCfgPumpsExtraFlowRate OBJECT-TYPE If the cooling system is used for further components the flow rate can be increased in two steps. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.11 | Unsigned32 (0..2) | read-write | current |
| lqCfgAntiFreeze OBJECT-TYPE Used to define whether or not the fans at the heat exchanger are to switch off if the temperature drops well below the specified temperature. off(2): The fans switch off. This setting is recommended in order to reduce the energy consumption of the cooling system. on(1): The fans continue to run even at low outside temperatures. This setting is recommended if the risk of fan seizure due to freezing is to be reduced. Note: Even if antifreeze mode is active, the condensation protection function of the transmitter will still switch off the fans at an inlet temperature below approx. +10 deg C. The fans are designed in such a way that they are not damaged if they seize up due to freezing. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.12 | SwitchOnOff | read-write | current |
| lqCfgAutoOn OBJECT-TYPE If set to alwaysOn(1), the cooling system is switched on irrespective of whether or not the transmitter is on. This setting should only be used when putting the system into operation. If the switch is set to autoOn(2), the cooling system is switched on/off when the transmitter is switched on/off. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.13 | INTEGER {alwaysOn(1), autoOn(2)} | read-write | current |
| compactCoolingConfigTable OBJECT-TYPE Compact liquid cooling configuration. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2 | not-accessible | current | |
| compactCoolingConfigEntry OBJECT-TYPE An entry in the compactCoolingConfigTable table. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1 | not-accessible | current | |
| compactCfgCycleIdx OBJECT-TYPE Integrated small cooling cycle index. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.1 | Unsigned32 (1) | not-accessible | current |
| compactCfgHeatExchangers OBJECT-TYPE Number of heat exchangers. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.2 | Unsigned32 (1..2) | read-write | current |
| compactCfgFans OBJECT-TYPE Number of fans per heat exchanger. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.3 | Unsigned32 (0..2) | read-write | current |
| compactCfgCoolantTemperatureFaultLimit OBJECT-TYPE A coolant temperature exceeding this value will lead to an error. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.4 | Integer32 (50..65) | read-write | current |
| compactCfgCoolantTemperatureWarningLimit OBJECT-TYPE A coolant temperature exceeding this value will lead to a warning. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.5 | Integer32 (40..65) | read-write | current |
| compactCfgCoolantPressureFaultLimit OBJECT-TYPE A coolant pressure equal or below this value will lead to an error. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.6 | Unsigned32 (0..40) | read-write | current |
| compactCfgCoolantPressureWarningLimit OBJECT-TYPE A coolant pressure equal or below this value will lead to a warning. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.7 | Unsigned32 (0..40) | read-write | current |
| compactCfgPumpsExtraFlowRate OBJECT-TYPE If the cooling system is used for further components the flow rate can be increased in two steps. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.8 | Unsigned32 (0..2) | read-write | current |
| compactCfgAutoOn OBJECT-TYPE If set to alwaysOn(1), the cooling system is switched on irrespective of whether or not the transmitter is on. This setting should only be used when putting the system into operation. If the switch is set to autoOn(2), the cooling system is switched on/off when the transmitter is switched on/off. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.9 | INTEGER {alwaysOn(1), autoOn(2)} | read-write | current |
| compactCfgServiceMode OBJECT-TYPE Reduces cooling faults to warnings temporariliy. To keep the transmitter on air when changing a pump the service mode should be activated. The service mode deactivates itself after 5 hours or after a reboot of the system control unit. | 1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.10 | SwitchOnOff | read-write | current |
| rsXx9LiquidCoolingConformance OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.2 | |||
| rsXx9LqCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.2.1 | |||
| rsXx9LqGroups OBJECT-IDENTITY | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| lqSummary NOTIFICATION-TYPE The cooling, assigned to this transmitter, reports a failure. To get more information check the system logbook and the shared system cooling. Possible values: off(2) - fault(3) - warning(4) - ok(5) - Notification class: fault | 1.3.6.1.4.1.2566.127.1.2.216.100.0.1 | current |
| lqFilterSummary NOTIFICATION-TYPE Indicates a polluted filter in cooling cycle. Please clean the filter located to the pump unit. Possible values: off(2) - warning(4) - liquid filter is polluted ok(5) - liquid filter is clean Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.100.0.2 | current |
| lqSensorsSummary NOTIFICATION-TYPE Liquid cooling sensors (inlet temperature, outlet temperature, pressure) summary state. Possible values: off(2) - fault(3) - pressure sensor fault warning(4) - temperature sensor warning ok(5) - Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.100.0.3 | current |
| lqSiteWarning NOTIFICATION-TYPE Warnings from the site cooling system. Applicable only if the appropriate signals from the site cooling system are supplied via terminal x8000 of the mains distribution board (MDB). Possible values: off(2) - warning(4) - ok(5) - Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.100.0.4 | current |
| lqSiteFault NOTIFICATION-TYPE Faults from the site cooling system. Applicable only if the appropriate signals from the site cooling system are supplied via terminal x8000 of the mains distribution board (MDB). Possible values: off(2) - fault(3) - ok(5) - Notification class: warning | 1.3.6.1.4.1.2566.127.1.2.216.100.0.5 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| lqRsCompliance MODULE-COMPLIANCE The compliance statement for the XX9000 liquid cooling system if lqCfgType is coolingRS(1). | 1.3.6.1.4.1.2566.127.1.2.216.100.2.1.1 | current |
| lqSiteCompliance MODULE-COMPLIANCE The compliance statement for the XX9000 liquid cooling system if lqCfgType is coolingSite(2). | 1.3.6.1.4.1.2566.127.1.2.216.100.2.1.2 | current |
| lqRsSmallCompliance MODULE-COMPLIANCE The compliance statement for the XX9000 liquid cooling system if lqCfgType is coolingRSsmall(3). | 1.3.6.1.4.1.2566.127.1.2.216.100.2.1.3 | current |
| lqCompactCompliance MODULE-COMPLIANCE The compliance statement for the XX9000 compact liquid cooling system. ISCooling has a maximum number of 2 Fans. | 1.3.6.1.4.1.2566.127.1.2.216.100.2.1.4 | current |
| rsXx9LqObjCommon OBJECT-GROUP common (non ISC) liquid cooling objects | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.1 | current |
| rsXx9LqObjRS OBJECT-GROUP Additional R&S liquid cooling objects | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.2 | current |
| rsXx9LqObjSmall OBJECT-GROUP Additional objects for small liquid cooling. | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.3 | current |
| rsXx9LqNotifyCommon NOTIFICATION-GROUP common liquid cooling notifications | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.4 | current |
| rsXx9LqNotifyRS NOTIFICATION-GROUP Additional R&S liquid cooling notifications | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.5 | current |
| rsXx9LqNotifySite NOTIFICATION-GROUP Additional site liquid cooling notifications | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.6 | current |
| rsXx9LqObjsObsoleted OBJECT-GROUP Obsoleted objects. | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.7 | obsolete |
| rsXx9CompactCoolingObjs OBJECT-GROUP Compact liquid cooling objects. | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.100 | current |
| rsXx9CompactCoolingNotify NOTIFICATION-GROUP Compact liquid cooling notifications. | 1.3.6.1.4.1.2566.127.1.2.216.100.2.2.200 | current |