MIBs Depot

RS-XX9-LIQUID-COOLING-MIB

Registered at
1.3.6.1.4.1.2566.127.1.2.216.100.0
1.3.6.1.4.1.2566.127.1.2.216.100.1
1.3.6.1.4.1.2566.127.1.2.216.100.2
1.3.6.1.4.1.2566.149.1.216.100
Last updated
2015-11-30 17:00
Organization
Rohde&Schwarz GmbH & Co. KG
Revisions
2015-11-30 17:00, 2015-08-20 15:00, 2015-06-23 12:00, 2015-02-27 15:00, 2014-12-22 16:00, 2013-10-07 12:00, 2013-01-31 13:00, 2012-05-11 08:00, 2012-01-26 08:00
Namespace
rs
Source file
RS-XX9-LIQUID-COOLING-MIB
Digest
sha256:61fd485eb8dfbbb7b72eb1716db4c6089cba2ec3c90b3d616e87ced6056cf782

Description

This MIB defines liquid cooling specific objects of XX9000 transmitting systems from Rohde & Schwarz. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB. - RS-XX9-SMI-MIB - mandatory for this MIB. - RS-XX9-TC-MIB - mandatory for this MIB. - RS-XX9-COMMON-MIB - mandatory for this MIB.

Contact

Rohde & Schwarz GmbH & Co. KG Broadcasting Division Muehldorfstrasse 15 81671 Munich Germany customersupport@rohde-schwarz.com

Imports

FromSymbols
RS-XX9-COMMON-MIBcommonNotificationAlarmClass
RS-XX9-SMI-MIBrsXx9LiquidCooling, rsXx9MibModule
RS-XX9-TC-MIBNotificationMask, NotificationPriority, NotificationState, SwitchOnOff
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
IANA-ENTITY-MIB
INET-ADDRESS-MIB
RS-COMMON-MIB
RS-XX9-COMMON-MIB
RS-XX9-LIQUID-COOLING-MIB
RS-XX9-SMI-MIB
RS-XX9-TC-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Objects

NameOIDSyntaxAccessStatus
rsXx9LiquidCoolingNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.0
rsXx9LiquidCoolingObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.1
lqStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.1.1
lqNotificationTable
OBJECT-TYPE
The context information/configuration for the liquid cooling status notifications.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1not-accessiblecurrent
lqNotificationEntry
OBJECT-TYPE
An entry in the lqNotificationTable.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1not-accessiblecurrent
lqNotificationCycleIdx
OBJECT-TYPE
Liquid cooling cycle index.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.1Unsigned32 (1..12)not-accessiblecurrent
lqNotificationIdx
OBJECT-TYPE
The notification number as below rsXx9LiquidCoolingNotifications. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.2Unsigned32 (1..5)not-accessiblecurrent
lqNotificationName
OBJECT-TYPE
The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9LiquidCoolingNotifications.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.3INTEGER {lqSummary(1), lqFilterSummary(2), lqSensorsSummary(3), lqSiteWarning(4), lqSiteFault(5)}read-onlycurrent
lqNotificationMask
OBJECT-TYPE
See textual convention for details.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.4NotificationMaskread-writecurrent
lqNotificationPriority
OBJECT-TYPE
See textual convention for details.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.5NotificationPriorityread-writecurrent
lqNotificationState
OBJECT-TYPE
See textual convention for details.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.1.1.6NotificationStateread-onlycurrent
lqStateTable
OBJECT-TYPE
Liquid cooling state information.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2not-accessiblecurrent
lqStateEntry
OBJECT-TYPE
An entry in the lqStateTable.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1not-accessiblecurrent
lqStInletTemperature
OBJECT-TYPE
Temperature of the pouring in coolant.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.2Integer32read-onlycurrent
lqStInletTemperatureSensor
OBJECT-TYPE
Indicates whether the inlet temperature sensor is working. If a fault is displayed, please check the connection between sensor and cooling interface which is located in TCE900 System Control. fault(3) - sensor fault ok(5) - sensor is working.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.3NotificationStateread-onlycurrent
lqStInletTemperatureSumState
OBJECT-TYPE
Indicates whether the inlet temperature of coolant is too high. If this problem is not caused by the ambient air temperature of heat exchangers the pumps and the fans of heat exchanger should be checked and the filter should be cleaned. fault(3) - exceeds fault limit warning(4) - exceeds warning limit ok(5) - is ok
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.4NotificationStateread-onlycurrent
lqStOutletTemperature
OBJECT-TYPE
Temperature of coolant before going into heat exchanger.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.5Integer32read-onlycurrent
lqStOutletTemperatureSensor
OBJECT-TYPE
Indicates the status of the temperature sensor at the outlet of the rack.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.6NotificationStateread-onlycurrent
lqStOutletTemperatureSumState
OBJECT-TYPE
Indicates whether the outlet temperature of coolant is too high. If this problem is not caused by the ambient air temperature of heat exchangers the pumps and the fans of heat exchanger should be checked and the filter should be cleaned. The display of this alarm disappears when the outlet temperature is lower than the selected warning limit. off(2) fault(3) - exceeds fault limit warning(4) - exceeds warning limit ok(5) - is ok
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.7NotificationStateread-onlycurrent
lqStCoolantPressure
OBJECT-TYPE
Coolant pressure.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.8Unsigned32read-onlycurrent
lqStCoolantPressureSensor
OBJECT-TYPE
Coolant pressure sensor state.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.9NotificationStateread-onlycurrent
lqStCoolantPressureSumState
OBJECT-TYPE
Indicates whether the coolant pressure is too low. If a fault is displayed the cooling equipment should be checked for a leakage and the filter should be cleaned. Possible values: off(2) - fault(3) - sensor fault warning(4) - ok(5) -
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.10NotificationStateread-onlycurrent
lqStInletTemperatureFaultLimit
OBJECT-TYPE
If the outlet temperature sensor is defective then an inlet temperature exceeding this value will lead to an error.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.11Integer32read-onlyobsolete
lqStInletTemperatureWarningLimit
OBJECT-TYPE
If the outlet temperature sensor is defective then an inlet temperature exceeding this value will lead to a warning.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.12Integer32read-onlyobsolete
lqStCompactPumpDesiredSpeed
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.2.1.13Unsigned32 (0..100)read-onlycurrent
lqPumpStateTable
OBJECT-TYPE
pump state information
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3not-accessiblecurrent
lqPumpStateEntry
OBJECT-TYPE
An entry in the lqPumpStateTable.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1not-accessiblecurrent
lqPStPumpIdx
OBJECT-TYPE
pump index
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.2Unsigned32 (1..2)not-accessiblecurrent
lqPStCommunicationState
OBJECT-TYPE
State of communication between TCE and pump.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.3NotificationStateread-onlycurrent
lqPStSumState
OBJECT-TYPE
pump summary state
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.4NotificationStateread-onlycurrent
lqPStMotorBlocked
OBJECT-TYPE
Indicates whether the pump motor can run freely or is mechanically blocked. To rectify this fault, the pump must be disassembled and checked for foreign objects. off(2) fault(3) - blocked ok(5)
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.5NotificationStateread-onlycurrent
lqPStOperatingHours
OBJECT-TYPE
Operating hours of pump.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.6Unsigned32read-onlycurrent
lqPStType
OBJECT-TYPE
Indicates the used pump type. The displayed type is identical to the type specified on the type plate of the pump. The type 'Magna2: 40-100' should be used for transmitters with up to 6 amplifiers. The type 'Magna2: 32-120' should be used for transmitters with more than 6 amplifiers.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.7SnmpAdminStringread-onlycurrent
lqPStCurrentFlowRate
OBJECT-TYPE
current flow rate of pump
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.8Unsigned32read-onlycurrent
lqPStCurrentSpeed
OBJECT-TYPE
rotational speed of pump motor
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.3.1.9Unsigned32read-onlycurrent
lqFanStateTable
OBJECT-TYPE
fan state table
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4not-accessiblecurrent
lqFanStateEntry
OBJECT-TYPE
An entry in the lqFanStateTable.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1not-accessiblecurrent
lqFStFanIdx
OBJECT-TYPE
fan index
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.1Unsigned32 (1..4)not-accessiblecurrent
lqFStCommunicationState
OBJECT-TYPE
Indicates whether the assigned fan is correctly registered on the fan communication bus. If a fault is displayed the corresponding task to re-register the fans on its communication bus should be started. Possible values: off(2) - fault(3) - not found ok(5) - installed
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.2NotificationStateread-onlycurrent
lqFStSumState
OBJECT-TYPE
fan summary state
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.3NotificationStateread-onlycurrent
lqFStMotorBlocked
OBJECT-TYPE
Shows whether the fan motor is mechanical blocked.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.4NotificationStateread-onlycurrent
lqFStOperatingHours
OBJECT-TYPE
fan operating hours
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.5Unsigned32read-onlycurrent
lqFStSupplyFailure
OBJECT-TYPE
Shows whether the fan is disconnected from power supply.
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.6NotificationStateread-onlycurrent
lqFStCurrentSpeed
OBJECT-TYPE
rotational speed of fan motor
1.3.6.1.4.1.2566.127.1.2.216.100.1.1.4.1.7Unsigned32read-onlycurrent
lqConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.1.2
lqConfigTable
OBJECT-TYPE
Liquid cooling configuration.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1not-accessiblecurrent
lqConfigEntry
OBJECT-TYPE
An entry in the lqConfigTable table.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1not-accessiblecurrent
lqCfgCycleIdx
OBJECT-TYPE
Liquid cooling cycle index.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.1Unsigned32 (1..12)not-accessiblecurrent
lqCfgType
OBJECT-TYPE
coolingRS(1) - XX9 cooling system coolingSite(2) - already existing site cooling coolingRSsmall(3) - small XX9 cooling system cooling8000(4) - legacy XX8000 cooling system
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.2INTEGER {coolingRS(1), coolingSite(2), coolingRSsmall(3), cooling8000(4)}read-writecurrent
lqCfgHeatExchangersPerRack
OBJECT-TYPE
Number of heat exchangers per rack.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.3Unsigned32 (1..2)read-writecurrent
lqCfgFansPerHeatExchanger
OBJECT-TYPE
Number of fans per heat exchanger.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.4Unsigned32 (1..2)read-writecurrent
lqCfgCoolantSetPointTemperature
OBJECT-TYPE
The nominal value of the coolant temperature for fan control.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.5Integer32 (20..65)read-writecurrent
lqCfgCoolantTemperatureFaultLimit
OBJECT-TYPE
A coolant temperature exceeding this value will lead to an error.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.6Integer32 (50..65)read-writecurrent
lqCfgCoolantTemperatureWarningLimit
OBJECT-TYPE
A coolant temperature exceeding this value will lead to a warning.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.7Integer32 (40..65)read-writecurrent
lqCfgCoolantPressureFaultLimit
OBJECT-TYPE
A coolant pressure equal or below this value will lead to an error.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.8Unsigned32 (0..40)read-writecurrent
lqCfgCoolantPressureWarningLimit
OBJECT-TYPE
A coolant pressure equal or below this value will lead to a warning.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.9Unsigned32 (0..40)read-writecurrent
lqCfgFanMaxSpeed
OBJECT-TYPE
You can diminish the fan speed for noise reduction. But this may lead to an unwanted increase of coolant temperature.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.10Unsigned32 (50..100)read-writecurrent
lqCfgPumpsExtraFlowRate
OBJECT-TYPE
If the cooling system is used for further components the flow rate can be increased in two steps.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.11Unsigned32 (0..2)read-writecurrent
lqCfgAntiFreeze
OBJECT-TYPE
Used to define whether or not the fans at the heat exchanger are to switch off if the temperature drops well below the specified temperature. off(2): The fans switch off. This setting is recommended in order to reduce the energy consumption of the cooling system. on(1): The fans continue to run even at low outside temperatures. This setting is recommended if the risk of fan seizure due to freezing is to be reduced. Note: Even if antifreeze mode is active, the condensation protection function of the transmitter will still switch off the fans at an inlet temperature below approx. +10 deg C. The fans are designed in such a way that they are not damaged if they seize up due to freezing.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.12SwitchOnOffread-writecurrent
lqCfgAutoOn
OBJECT-TYPE
If set to alwaysOn(1), the cooling system is switched on irrespective of whether or not the transmitter is on. This setting should only be used when putting the system into operation. If the switch is set to autoOn(2), the cooling system is switched on/off when the transmitter is switched on/off.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.1.1.13INTEGER {alwaysOn(1), autoOn(2)}read-writecurrent
compactCoolingConfigTable
OBJECT-TYPE
Compact liquid cooling configuration.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2not-accessiblecurrent
compactCoolingConfigEntry
OBJECT-TYPE
An entry in the compactCoolingConfigTable table.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1not-accessiblecurrent
compactCfgCycleIdx
OBJECT-TYPE
Integrated small cooling cycle index.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.1Unsigned32 (1)not-accessiblecurrent
compactCfgHeatExchangers
OBJECT-TYPE
Number of heat exchangers.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.2Unsigned32 (1..2)read-writecurrent
compactCfgFans
OBJECT-TYPE
Number of fans per heat exchanger.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.3Unsigned32 (0..2)read-writecurrent
compactCfgCoolantTemperatureFaultLimit
OBJECT-TYPE
A coolant temperature exceeding this value will lead to an error.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.4Integer32 (50..65)read-writecurrent
compactCfgCoolantTemperatureWarningLimit
OBJECT-TYPE
A coolant temperature exceeding this value will lead to a warning.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.5Integer32 (40..65)read-writecurrent
compactCfgCoolantPressureFaultLimit
OBJECT-TYPE
A coolant pressure equal or below this value will lead to an error.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.6Unsigned32 (0..40)read-writecurrent
compactCfgCoolantPressureWarningLimit
OBJECT-TYPE
A coolant pressure equal or below this value will lead to a warning.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.7Unsigned32 (0..40)read-writecurrent
compactCfgPumpsExtraFlowRate
OBJECT-TYPE
If the cooling system is used for further components the flow rate can be increased in two steps.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.8Unsigned32 (0..2)read-writecurrent
compactCfgAutoOn
OBJECT-TYPE
If set to alwaysOn(1), the cooling system is switched on irrespective of whether or not the transmitter is on. This setting should only be used when putting the system into operation. If the switch is set to autoOn(2), the cooling system is switched on/off when the transmitter is switched on/off.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.9INTEGER {alwaysOn(1), autoOn(2)}read-writecurrent
compactCfgServiceMode
OBJECT-TYPE
Reduces cooling faults to warnings temporariliy. To keep the transmitter on air when changing a pump the service mode should be activated. The service mode deactivates itself after 5 hours or after a reboot of the system control unit.
1.3.6.1.4.1.2566.127.1.2.216.100.1.2.2.1.10SwitchOnOffread-writecurrent
rsXx9LiquidCoolingConformance
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.2
rsXx9LqCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.2.1
rsXx9LqGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.100.2.2

Notifications

NameOIDStatus
lqSummary
NOTIFICATION-TYPE
The cooling, assigned to this transmitter, reports a failure. To get more information check the system logbook and the shared system cooling. Possible values: off(2) - fault(3) - warning(4) - ok(5) - Notification class: fault
1.3.6.1.4.1.2566.127.1.2.216.100.0.1current
lqFilterSummary
NOTIFICATION-TYPE
Indicates a polluted filter in cooling cycle. Please clean the filter located to the pump unit. Possible values: off(2) - warning(4) - liquid filter is polluted ok(5) - liquid filter is clean Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.100.0.2current
lqSensorsSummary
NOTIFICATION-TYPE
Liquid cooling sensors (inlet temperature, outlet temperature, pressure) summary state. Possible values: off(2) - fault(3) - pressure sensor fault warning(4) - temperature sensor warning ok(5) - Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.100.0.3current
lqSiteWarning
NOTIFICATION-TYPE
Warnings from the site cooling system. Applicable only if the appropriate signals from the site cooling system are supplied via terminal x8000 of the mains distribution board (MDB). Possible values: off(2) - warning(4) - ok(5) - Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.100.0.4current
lqSiteFault
NOTIFICATION-TYPE
Faults from the site cooling system. Applicable only if the appropriate signals from the site cooling system are supplied via terminal x8000 of the mains distribution board (MDB). Possible values: off(2) - fault(3) - ok(5) - Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.100.0.5current

Conformance

NameOIDStatus
lqRsCompliance
MODULE-COMPLIANCE
The compliance statement for the XX9000 liquid cooling system if lqCfgType is coolingRS(1).
1.3.6.1.4.1.2566.127.1.2.216.100.2.1.1current
lqSiteCompliance
MODULE-COMPLIANCE
The compliance statement for the XX9000 liquid cooling system if lqCfgType is coolingSite(2).
1.3.6.1.4.1.2566.127.1.2.216.100.2.1.2current
lqRsSmallCompliance
MODULE-COMPLIANCE
The compliance statement for the XX9000 liquid cooling system if lqCfgType is coolingRSsmall(3).
1.3.6.1.4.1.2566.127.1.2.216.100.2.1.3current
lqCompactCompliance
MODULE-COMPLIANCE
The compliance statement for the XX9000 compact liquid cooling system. ISCooling has a maximum number of 2 Fans.
1.3.6.1.4.1.2566.127.1.2.216.100.2.1.4current
rsXx9LqObjCommon
OBJECT-GROUP
common (non ISC) liquid cooling objects
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.1current
rsXx9LqObjRS
OBJECT-GROUP
Additional R&S liquid cooling objects
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.2current
rsXx9LqObjSmall
OBJECT-GROUP
Additional objects for small liquid cooling.
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.3current
rsXx9LqNotifyCommon
NOTIFICATION-GROUP
common liquid cooling notifications
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.4current
rsXx9LqNotifyRS
NOTIFICATION-GROUP
Additional R&S liquid cooling notifications
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.5current
rsXx9LqNotifySite
NOTIFICATION-GROUP
Additional site liquid cooling notifications
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.6current
rsXx9LqObjsObsoleted
OBJECT-GROUP
Obsoleted objects.
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.7obsolete
rsXx9CompactCoolingObjs
OBJECT-GROUP
Compact liquid cooling objects.
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.100current
rsXx9CompactCoolingNotify
NOTIFICATION-GROUP
Compact liquid cooling notifications.
1.3.6.1.4.1.2566.127.1.2.216.100.2.2.200current