MIBs Depot

RS-XX9-ISDBT-MIB

Registered at
1.3.6.1.4.1.2566.127.1.2.216.8.0
1.3.6.1.4.1.2566.127.1.2.216.8.1
1.3.6.1.4.1.2566.127.1.2.216.8.2
1.3.6.1.4.1.2566.149.1.216.8
Last updated
2015-06-03 15:00
Organization
Rohde&Schwarz GmbH & Co. KG
Revisions
2015-06-03 15:00, 2014-12-22 16:00, 2014-03-25 16:00, 2012-05-14 10:00
Namespace
rs
Source file
RS-XX9-ISDBT-MIB
Digest
sha256:ba1be3a0698971e22eb41b0326e06c3eb3103d9c30f756b89765dc9898048aec

Description

This MIB defines ISDB-T specific objects of XX9000 transmitting systems from Rohde & Schwarz. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB - RS-XX9-SMI-MIB - mandatory for this MIB - RS-XX9-TC-MIB - mandatory for this MIB - RS-XX9-COMMON-MIB - mandatory for this MIB

Contact

Rohde & Schwarz GmbH & Co. KG Broadcasting Division Muehldorfstrasse 15 81671 Munich Germany customersupport@rohde-schwarz.com

Imports

FromSymbols
RS-XX9-COMMON-MIBcommonNotificationAlarmClass
RS-XX9-SMI-MIBrsXx9IsdbT, rsXx9MibModule
RS-XX9-TC-MIBIndexAB, IndexTransmitter, NotificationClass, NotificationMask, NotificationPriority, NotificationState, SwitchOnOff
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
IANA-ENTITY-MIB
INET-ADDRESS-MIB
RS-COMMON-MIB
RS-XX9-COMMON-MIB
RS-XX9-ISDBT-MIB
RS-XX9-SMI-MIB
RS-XX9-TC-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
IsdbtCodeRate
TEXTUAL-CONVENTION
The coderate sets the ratio between payload and error correction information.
current
IsdbtConstellation
TEXTUAL-CONVENTION
Description.
current
IsdbtGuardInterval
TEXTUAL-CONVENTION
The Guard Interval determines the time span between signals for multicarrier modulation, in which no information is transmitted. The larger the time span is, the lower the risk of interference and the lower the data transfer rate. The values are a fraction of the symbol period. Ideally, you select a value that is larger than the channel spread.
current
IsdbtLayer
TEXTUAL-CONVENTION
Description.
current
IsdbtMode
TEXTUAL-CONVENTION
Selects the FFT size: mode1(2) - 2048 carriers mode2(3) - 4096 carriers mode3(4) - 8192 carriers
current
IsdbtNitRestampingSource
TEXTUAL-CONVENTION
Description.
current

Objects

NameOIDSyntaxAccessStatus
rsXx9IsdbtNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.0
rsXx9IsdbtObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.1
isdbtStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.1.1
isdbtStatusNotificationTable
OBJECT-TYPE
The context information/configuration for the ISDB-T status notifications.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1not-accessiblecurrent
isdbtStatusNotificationEntry
OBJECT-TYPE
An entry in the isdbtStatusNotificationTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1not-accessiblecurrent
isdbtStatusNotificationTxIdx
OBJECT-TYPE
The transmitter index.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.1IndexTransmitternot-accessiblecurrent
isdbtStatusNotificationExcIdx
OBJECT-TYPE
This index distinguishes the exiters. Necessary if you have dual drive transmitters.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.2IndexABnot-accessiblecurrent
isdbtStatusNotificationIdx
OBJECT-TYPE
The notification number as below rsXx9IsdbtNotifications. This is a helper column and therefore not-accessible.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.3Unsigned32 (1..6)not-accessiblecurrent
isdbtStatusNotificationName
OBJECT-TYPE
The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9IsdbtNotifications.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.4INTEGER {isdbtIIP(1), isdbtFrameCounter(2), isdbtEquipmentId(3), isdbtManualConfiguration(4), isdbtActiveConfiguration(5), isdbtTest(6)}read-writecurrent
isdbtStatusNotificationMask
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.5NotificationMaskread-writecurrent
isdbtStatusNotificationPriority
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.6NotificationPriorityread-writecurrent
isdbtStatusNotificationState
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.1.1.7NotificationStateread-onlycurrent
isdbtStateTable
OBJECT-TYPE
ISDB-T state values.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.2not-accessiblecurrent
isdbtStateEntry
OBJECT-TYPE
An entry in the isdbtStateTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.2.1not-accessiblecurrent
isdbtStTxDelayOffset
OBJECT-TYPE
Transmitting time shift compared to other transmitters in the ISDB-T network.
1.3.6.1.4.1.2566.127.1.2.216.8.1.1.2.1.1Integer32read-onlycurrent
isdbtSetup
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.1.2
isdbtConfigurationTable
OBJECT-TYPE
ISDB-T configuration.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1not-accessiblecurrent
isdbtConfigurationEntry
OBJECT-TYPE
An entry in the isdbtConfigurationTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1not-accessiblecurrent
isdbtCfgTxIdx
OBJECT-TYPE
The transmitter index.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1.1IndexTransmitternot-accessiblecurrent
isdbtCfgExcIdx
OBJECT-TYPE
This index distinguishes the exiters. Necessary if you have dual drive transmitters.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1.2IndexABnot-accessiblecurrent
isdbtCfgNetworkMode
OBJECT-TYPE
It can be switched between Single Frequency Networks and Multiple Frequency Networks.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1.3INTEGER {mfn(1), dynamicSfn(2), staticSfn(3), automatic(4)}read-writecurrent
isdbtCfgCoderSettingsSource
OBJECT-TYPE
Selects the source for the TMCC (Transmission and Multiplexing Configuration Control) input parameter for the ISDB-T coder. iip(1) - parameters are read out of the IIP in the transmission manual(2) - parameters are configured in the transmitter
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1.4INTEGER {iip(1), manual(2)}read-writecurrent
isdbtCfgIipID
OBJECT-TYPE
PID (packet ID) number for the IIP (ISDB-T information packet) in the input data stream. Requirement is that isdbtCfgCoderSettingsSource is iip(1).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1.5Unsigned32 (0..65535)read-writecurrent
isdbtCfgBandwidth
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.1.1.6INTEGER {mhz6(5), mhz7(6), mhz8(7)}read-writecurrent
isdbtLocalizationTable
OBJECT-TYPE
ISDB-T localization.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.2not-accessiblecurrent
isdbtLocalizationEntry
OBJECT-TYPE
An entry in the isdbtLocalizationTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.2.1not-accessiblecurrent
isdbtLocalizationEquipmentControl
OBJECT-TYPE
Activates or deactivates the device ID. This way transmitter-specific settings may be configured via the ISDB-T information packet present in the transport stream. Operation is possible if isdbtCfgCoderSettingsSource is iip(1).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.2.1.1SwitchOnOffread-writecurrent
isdbtLocalizationEquipmentID
OBJECT-TYPE
A unique device ID, to be able to reference special settings of the IIP (ISDB-T information packet).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.2.1.2Unsigned32 (0..65535)read-writecurrent
isdbtTmccTable
OBJECT-TYPE
TMCC (transmission and multiplexing configuration control) configuration.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.3not-accessiblecurrent
isdbtTmccEntry
OBJECT-TYPE
An entry in the isdbtTmccTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.3.1not-accessiblecurrent
isdbtTmccNext
OBJECT-TYPE
Transmission and Multiplexing Configuration Control: off(1) - all TMCC NEXT is set to unused. active(2) - the TMCC NEXT contains the active coder setup. automatic(3) - the TMCC NEXT follows the IIP TMCC NEXT signalisation if available and used for coder source, otherwise the active coder setup is used.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.3.1.1INTEGER {off(1), active(2), automatic(3)}read-writecurrent
isdbtTmccMode
OBJECT-TYPE
see textual convention
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.3.1.2IsdbtModeread-writecurrent
isdbtTmccGuardInterval
OBJECT-TYPE
see textual convention
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.3.1.3IsdbtGuardIntervalread-writecurrent
isdbtTmccPartialReception
OBJECT-TYPE
If layer A for mobile reception is to be used (1-segment receiver), set 'Partial Reception' to on(1). In this case, segment 0 is arranged in the band center. The value can be entered manually and is used for TMCC NEXT (transmission and multiplexing configuration control NEXT) if isdbtTmccNext is set to active(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.3.1.4SwitchOnOffread-writecurrent
isdbtTmccLayerTable
OBJECT-TYPE
TMCC layer configuration.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4not-accessiblecurrent
isdbtTmccLayerEntry
OBJECT-TYPE
An entry in the isdbtTmccLayerTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4.1not-accessiblecurrent
isdbtTmccLayerIdx
OBJECT-TYPE
TMCC layer index.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4.1.3IsdbtLayernot-accessiblecurrent
isdbtTmccLayerSegments
OBJECT-TYPE
Number of segments used for the layer concerned. The allocation of segments to the layers is subject to conditions: 0 - layer is deactivated. For layer A, 0 is not permitted. For layer B, 0 is possible only if layer C also has 0 segments. The sum of all the segments from all the active layers must always be 13. The segments can be distributed over 1, 2 or 3 layers. An allocation of 1 single segment is possible only for layer A. This is only allowed if isdbtTmccPartialReception is on(1). The remaining 12 segments can be distributed over layers B and C according to the above rules.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4.1.4Unsigned32 (0..13)read-writecurrent
isdbtTmccLayerConstellation
OBJECT-TYPE
Configure the modulation format with this parameter. qpsk(3) - is very fail-safe, but has only a small data rate. qam64(5) - can transmit very large data rates if you expect faults on the transmission link. qam16(4) - is a compromise between the two other setting values. The value can be entered manually and is used for TMCC NEXT (transmission and multiplexing configuration control NEXT) if isdbtTmccNext is set to active(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4.1.5IsdbtConstellationread-writecurrent
isdbtTmccLayerCodeRate
OBJECT-TYPE
see textual convention.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4.1.6IsdbtCodeRateread-writecurrent
isdbtTmccLayerTimeInterleaver
OBJECT-TYPE
To reduce the susceptibility to faults when there is noise, the time interleaver mixes the user data in a data block. 0, 1, 2, 4, 8, and 16 can be selected as conversion length. 0 means that no conversion take place, 16 corresponds to the highest degree of conversion. This offers the greatest protection, but also the greatest latency. The value can be entered manually and is used for TMCC NEXT (transmission and multiplexing configuration control NEXT) if isdbtTmccNext is set to active(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.4.1.7Unsigned32 (0..2 | 4 | 8 | 16)read-writecurrent
isdbtTestTable
OBJECT-TYPE
Configures the test mode of the exciter.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.5not-accessiblecurrent
isdbtTestEntry
OBJECT-TYPE
An entry in the isdbtTestTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.5.1not-accessiblecurrent
isdbtTestGeneration
OBJECT-TYPE
Switches test signal generation on or off.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.5.1.1SwitchOnOffread-writeobsolete
isdbtTestMode
OBJECT-TYPE
off(1) - no test mode testMode0(4) - For activating a test sequence with three layers, ISDB-T mode 1 and guard interval 1/4. Layer A: 1 segment, DQPSK, code rate 1/2, time interleaver: 0 Layer B: 7 segments, 16QAM, code rate 7/8, time interleaver: 0 Layer C: 5 segments, 64QAM, code rate 2/3, time interleaver: 0 testMode1(5) - For activating a test sequence with one layer, ISDB-T mode 1 and guard interval 1/4. Layer A: 13 segments, QPSK, code rate 1/2, time interleaver: 0
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.5.1.2INTEGER {off(1), testMode0(4), testMode1(5)}read-writecurrent
isdbtNitRestampingTable
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6not-accessiblecurrent
isdbtNitRestampingEntry
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1not-accessiblecurrent
isdbtNitNetworkIdSource
OBJECT-TYPE
This allows to enable the localization of the network id using a manual setup.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.1IsdbtNitRestampingSourceread-writecurrent
isdbtNitManualNetworkId
OBJECT-TYPE
This is a label to identify the network. Localization is done within each NIT. Only valid, if isdbtNitNetworkIdSource is set to manual(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.2Unsigned32 (0..65535)read-writecurrent
isdbtNitTransportStreamIdSource
OBJECT-TYPE
This allows to enable the localization of the transport stream id using a manual setup.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.3IsdbtNitRestampingSourceread-writecurrent
isdbtNitTransportManualStreamId
OBJECT-TYPE
This is a label to identify the transport stream from any other multiplex within the delivery system. Localization is done within each NIT, PAT, SDT, EIT, RST, PCAT and LDT. Only valid, if isdbtNitTransportStreamIdSource is set to manual(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.4Unsigned32 (0..65535)read-writecurrent
isdbtNitAreaCodeSource
OBJECT-TYPE
This allows to enable the localization of the area code using a manual setup.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.5IsdbtNitRestampingSourceread-writecurrent
isdbtNitManualAreaCode
OBJECT-TYPE
This is the service area code from terrestrial delivery system descriptor. Localization is done within each NIT. Only valid, if isdbtNitAreaCodeSource is set to manual(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.6Unsigned32 (0..4095)read-writecurrent
isdbtNitFrequencySource
OBJECT-TYPE
This allows to enable the localization of the frequency using a manual setup.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.7IsdbtNitRestampingSourceread-writecurrent
isdbtNitManualFrequency
OBJECT-TYPE
This is the first frequency within the list of frequencies from terrestrial delivery system descriptor. Localization is done within each NIT. Only valid, if isdbtNitFrequencySource is set to manual(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.8Unsigned32 (0..65535)read-writecurrent
isdbtNitVirtualChannelSource
OBJECT-TYPE
This allows to enable the localization of the virtual channel using a manual setup.
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.9IsdbtNitRestampingSourceread-writecurrent
isdbtNitManualVirtualChannel
OBJECT-TYPE
This indicates the recommended remote control key number to which the TS shall be assigned. This is also known as 'virtual channel'. Localization is done within each NIT. Only valid, if isdbtNitVirtualChannelSource is set to manual(2).
1.3.6.1.4.1.2566.127.1.2.216.8.1.2.6.1.10Unsigned32 (0..255)read-writecurrent
isdbtOutput
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.1.3
isdbtOutTmccTable
OBJECT-TYPE
TMCC (transmission and multiplexing configuration control) current values.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.3not-accessiblecurrent
isdbtOutTmccEntry
OBJECT-TYPE
An entry in the isdbtOutTmccTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.3.1not-accessiblecurrent
isdbtOutTmccMode
OBJECT-TYPE
see textual convention
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.3.1.2IsdbtModeread-onlycurrent
isdbtOutTmccGuardInterval
OBJECT-TYPE
see textual convention
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.3.1.3IsdbtGuardIntervalread-onlycurrent
isdbtOutTmccPartialReception
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.3.1.4TruthValueread-onlycurrent
isdbtOutTmccLayerTable
OBJECT-TYPE
TMCC layer current values.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.4not-accessiblecurrent
isdbtOutTmccLayerEntry
OBJECT-TYPE
An entry in the isdbtOutTmccLayerTable.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.4.1not-accessiblecurrent
isdbtOutTmccLayerSegments
OBJECT-TYPE
Number of segments manually set for layer.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.4.1.4Unsigned32read-onlycurrent
isdbtOutTmccLayerConstellation
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.4.1.5IsdbtConstellationread-onlycurrent
isdbtOutTmccLayerCodeRate
OBJECT-TYPE
see textual convention.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.4.1.6IsdbtCodeRateread-onlycurrent
isdbtOutTmccLayerTimeInterleaver
OBJECT-TYPE
Time interleaver used in layer. Value 0 means no interleaving.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.4.1.7Unsigned32read-onlycurrent
isdbtOutStatusTable
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.5not-accessiblecurrent
isdbtOutStatusEntry
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.5.1not-accessiblecurrent
isdbtOutStatusEwbsActFlag
OBJECT-TYPE
Indicates the status of the transmitted EWBS-Flag (EWBS=Emergency Warning Broadcast System). notAvailable(1): 'Switch On' information can not be detected in IIP (ISDB-T Information Packet). flagOff(2): IIP contains 'Switch On' = Off. flagOn(3): IIP contains 'Switch On' = On.
1.3.6.1.4.1.2566.127.1.2.216.8.1.3.5.1.1INTEGER {notAvailable(1), flagOff(2), flagOn(3)}read-onlycurrent
rsXx9IsdbtConformance
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.2
rsXx9IsdbtCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.2.1
rsXx9IsdbtGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.8.2.2

Notifications

NameOIDStatus
isdbtIIP
NOTIFICATION-TYPE
Shows whether ISDB-T information packets (IIP) with the appropriate ID are present in the transport stream Possible values: off(2) - isdbtCfgCoderSettingsSource is manual(2) fault(3) - the input data does not contain a IIP warning(4) - no SFN info ok(5) - IIP found Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.8.0.1current
isdbtFrameCounter
NOTIFICATION-TYPE
Shows the correctness of TSPs. Possible values: off(2) warning(4) - incorrect or missing TSP detected ok(5) Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.8.0.2current
isdbtEquipmentId
NOTIFICATION-TYPE
Shows the existence of SFN information matching the selected equipment ID. Possible values: off(2) - isdbtLocalizationEquipmentControl is off(2) or isdbtCfgCoderSettingsSource is manual(2) warning(4) - no matching SFN information ok(5) Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.8.0.3current
isdbtManualConfiguration
NOTIFICATION-TYPE
Indicates whether the configured ISDB-T configuration is consistent and valid over all three layers. If an error is displayed, check whether the sum of all segments over the three layers is exactly 13. Possible values: off(2) - warning(4) - not valid ok(5) - valid Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.8.0.4current
isdbtActiveConfiguration
NOTIFICATION-TYPE
Indicates whether the active ISDB-T configuration is consistent and valid over all three layers. If an error is displayed, check whether the sum of all segments over the three layers is exactly 13. Possible values: off(2) - warning(4) - not valid ok(5) - valid Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.8.0.5current
isdbtTest
NOTIFICATION-TYPE
Possible values: off(2) - no test signal generation warning(4) - test signal generation is activated Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.8.0.6current

Conformance

NameOIDStatus
isdbtBasicCompliance
MODULE-COMPLIANCE
The compliance statement for XX9000 ISDB-T exciters.
1.3.6.1.4.1.2566.127.1.2.216.8.2.1.1current
isdbtObjBasic
OBJECT-GROUP
Basic objects group.
1.3.6.1.4.1.2566.127.1.2.216.8.2.2.1current
isdbtNotifyBasic
NOTIFICATION-GROUP
Basic notifications group.
1.3.6.1.4.1.2566.127.1.2.216.8.2.2.2current
isdbtObjObsoleted
OBJECT-GROUP
Description.
1.3.6.1.4.1.2566.127.1.2.216.8.2.2.3obsolete