MIBs Depot

RS-XX9-DTMB-MIB

Registered at
1.3.6.1.4.1.2566.127.1.2.216.12.0
1.3.6.1.4.1.2566.127.1.2.216.12.1
1.3.6.1.4.1.2566.127.1.2.216.12.2
1.3.6.1.4.1.2566.149.1.216.12
Last updated
2015-06-23 11:00
Organization
Rohde&Schwarz GmbH & Co. KG
Revisions
2015-07-06 12:00, 2015-02-27 15:00, 2014-12-22 16:00, 2014-01-30 11:00, 2013-09-02 11:00, 2013-05-29 15:00
Namespace
rs
Source file
RS-XX9-DTMB-MIB
Digest
sha256:6462a1493a5a37b9c4df32b5908218ac6c051b482eef8a98cd515f710332c458

Description

This MIB defines DTMB specific objects of XX9000 transmitting systems from Rohde & Schwarz. The following MIBs are related to this: - RS-COMMON-MIB - mandatory for this MIB - RS-XX9-SMI-MIB - mandatory for this MIB - RS-XX9-TC-MIB - mandatory for this MIB - RS-XX9-COMMON-MIB - mandatory for this MIB

Contact

Rohde & Schwarz GmbH & Co. KG Broadcasting Division Muehldorfstrasse 15 81671 Munich Germany customersupport@rohde-schwarz.com

Imports

FromSymbols
RS-XX9-COMMON-MIBcommonNotificationAlarmClass
RS-XX9-SMI-MIBrsXx9Dtmb, rsXx9MibModule
RS-XX9-TC-MIBIndexAB, IndexTransmitter, NotificationMask, NotificationPriority, NotificationState, SwitchOnOff
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ENTITY-MIB
IANA-ENTITY-MIB
INET-ADDRESS-MIB
RS-COMMON-MIB
RS-XX9-COMMON-MIB
RS-XX9-DTMB-MIB
RS-XX9-SMI-MIB
RS-XX9-TC-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
UUID-TC-MIB

Textual conventions

NameOIDSyntaxAccessStatus
DtmbChannelBandwidth
TEXTUAL-CONVENTION
mhz6(5) - 6 MHz mhz7(6) - 7 MHz mhz8(7) - 8 MHz
current
DtmbCodeRate
TEXTUAL-CONVENTION
Description.
current
DtmbGuardInterval
TEXTUAL-CONVENTION
Description.
current
DtmbModulation
TEXTUAL-CONVENTION
Description.
current

Objects

NameOIDSyntaxAccessStatus
rsXx9DtmbNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.0
rsXx9DtmbObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.1
dtmbStatus
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.1.1
dtmbStatusNotificationTable
OBJECT-TYPE
The context information/configuration for the DTMB status notifications.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1not-accessiblecurrent
dtmbStatusNotificationEntry
OBJECT-TYPE
An entry in the dtmbStatusNotificationTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1not-accessiblecurrent
dtmbStatusNotificationTxIdx
OBJECT-TYPE
The transmitter index.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.1IndexTransmitternot-accessiblecurrent
dtmbStatusNotificationExcIdx
OBJECT-TYPE
This index distinguishes the exciters. Necessary if you have dual drive transmitters.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.2IndexABnot-accessiblecurrent
dtmbStatusNotificationIdx
OBJECT-TYPE
The notification number as below rsXx9DtmbNotifications. This is a helper column and therefore not accessible.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.3Unsigned32 (1..3)not-accessiblecurrent
dtmbStatusNotificationName
OBJECT-TYPE
The notification number as an enumeration. The enumeration correlates with the notifications under rsXx9DtmbNotifications.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.4INTEGER {dtmbEncoderSummary(1), dtmbManualConfiguration(2), dtmbActiveConfiguration(3), dtmbTest(4)}read-writecurrent
dtmbStatusNotificationMask
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.5NotificationMaskread-writecurrent
dtmbStatusNotificationPriority
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.6NotificationPriorityread-writecurrent
dtmbStatusNotificationState
OBJECT-TYPE
See TextualConvention for details.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.1.1.7NotificationStateread-onlycurrent
dtmbStateTable
OBJECT-TYPE
DTMB state values.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.2not-accessiblecurrent
dtmbStateEntry
OBJECT-TYPE
An entry in the dtmbStateTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.2.1not-accessiblecurrent
dtmbStTxDelayOffset
OBJECT-TYPE
Transmitting time shift compared to other transmitters in the DTMB network.
1.3.6.1.4.1.2566.127.1.2.216.12.1.1.2.1.1Integer32read-onlycurrent
dtmbSetup
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.1.2
dtmbConfigurationTable
OBJECT-TYPE
General DTMB configuration.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1not-accessiblecurrent
dtmbConfigurationEntry
OBJECT-TYPE
An entry in the dtmbConfigurationTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1.1not-accessiblecurrent
dtmbConfigurationTxIdx
OBJECT-TYPE
The transmitter index.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1.1.1IndexTransmitternot-accessiblecurrent
dtmbConfigurationExcIdx
OBJECT-TYPE
This index distinguishes the exiters. Necessary if you have dual drive transmitters.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1.1.2IndexABnot-accessiblecurrent
dtmbConfigurationTpsSource
OBJECT-TYPE
Source set for the TPS parameters (TPS = transmission parameter signaling). off(1) is an undefined setting and shall not be used. The following are possible sources: - MIP (megaframe initialization packet), - SIP (second frame initialization packet) - manually selected default settings.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1.1.3INTEGER {off(1), mip(2), manual(3), sip(4)}read-writecurrent
dtmbConfigurationInfoPacketReplacement
OBJECT-TYPE
Controls, whether the information packets (MIP or SIP) shall be contained in the outgiung datastream (off-2), or replaced by null-packets (on-3).
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1.1.4INTEGER {undefined(1), off(2), on(3)}read-writecurrent
dtmbConfigurationNetworkMode
OBJECT-TYPE
Used to activate time synchronization. MFN: The time of transmission is not controlled. SFN (MIP): The time of transmission of a symbol is the same for all the transmitters of a single-frequency network (SFN). The time of transmission signaled by the Megaframe Information Packet is used. SFN (SIP): The time of transmission of a symbol is the same for all the transmitters of a single-frequency network (SFN). The time of transmission signaled by the Session Initiation Protocol is used.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.1.1.5INTEGER {undefined(1), mfn(2), sfnMip(3), sfnSip(4)}read-writecurrent
dtmbModulationTable
OBJECT-TYPE
DTMB modulation parameters.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3not-accessiblecurrent
dtmbModulationEntry
OBJECT-TYPE
An entry in the dtmbModulationTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1not-accessiblecurrent
dtmbModulationChannelBandwidth
OBJECT-TYPE
Channel bandwidth occupied by the DTMB signal in the frequency spectrum. 6 MHz, 7 MHz or 8 MHz can be set. The choice depends on the required bandwidth of the channel to be transmitted.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.3DtmbChannelBandwidthread-writecurrent
dtmbModulationGuardInterval
OBJECT-TYPE
Padding mode for the guard interval. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.5DtmbGuardIntervalread-writecurrent
dtmbModulationConstellation
OBJECT-TYPE
Sets up the modulation mode. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.6DtmbModulationread-writecurrent
dtmbModulationCodeRate
OBJECT-TYPE
Sets the code rate. The code rate is used to set the ratio of information data to (error correction values + information data). 4/10 provides the greatest error correction and the lowest data transfer rate 8/10 provides the lowest error correction and the greatest data transfer rate. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.7DtmbCodeRateread-writecurrent
dtmbModulationTimeInterleaver
OBJECT-TYPE
Sets the mode for the time interleaver. The time interleaver distributes the payload data over many symbols in order to reduce noise sensitivity. The setting 720 symbols (s720-3) is recommended for a high error tolerance. If, on the other hand, the resulting delay is to be kept short, the setting 240 symbols (s240-2) is more suitable. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.8INTEGER {off(2), s240(3), s720(4)}read-writecurrent
dtmbModulationControlFrame
OBJECT-TYPE
obsolete parameter.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.9SwitchOnOffread-writeobsolete
dtmbModulationCarrierMode
OBJECT-TYPE
configures whether the signal should be transmitted in Single Carrier Mode (previously: ADTB-T) or in Multicarrier Mode (previously: DMB-T) with 3780 single carriers.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.10INTEGER {single(2), multi(3)}read-writecurrent
dtmbModulationDualPilotTone
OBJECT-TYPE
configures whether two additional pilot signals are to be inserted into the spectrum. The pilots are at +/- half symbol rate. The setting can be changed here. This parameter is effective only if Carrier Mode= Single has been selected.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.11SwitchOnOffread-writecurrent
dtmbModulationGuardIntervalPN
OBJECT-TYPE
Sets which PN sequence (pseudo random noise sequence) is used for the guard interval. Constant (3): The PN sequence Index 0 is always used Variable (2): All PN sequences will be used.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.3.1.12INTEGER {variable(2), constant(3)}read-writecurrent
dtmbTestTable
OBJECT-TYPE
Configures the test mode of the exciter.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.4not-accessiblecurrent
dtmbTestEntry
OBJECT-TYPE
An entry in the dtmbTestTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.4.1not-accessiblecurrent
dtmbTestMode
OBJECT-TYPE
sets which test signal is to be generated. - Off (1): switches off test signal generation. - PRBS (2): Generates a pseudo-random binary sequence insted of the payload. - Single Carrier (3): Generates an unmodulated single carrier. This test signal can be used to measure the phase noise of the synthesizer. The phase noise must be measured via the RF Monitor Out connector (X61). The cable connected to RF Out (X60) must be removed. In order to protect the amplifiers, this test signal is only generated if the output of the exciter is open.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.4.1.1INTEGER {off(1), prbs(2), singleCarrier(3)}read-writecurrent
dtmbTestCarrierPower
OBJECT-TYPE
sets level of the single carrier. This parameter is effective only if Carrier Mode = Single has been selected.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.4.1.2Unsigned32 (0..255)read-writecurrent
dtmbLocalizationTable
OBJECT-TYPE
DTMB localization parameters.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.5not-accessiblecurrent
dtmbLocalizationEntry
OBJECT-TYPE
An entry in the dtmbLocalizationTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.5.1not-accessiblecurrent
dtmbLocalizationTxControl
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.5.1.1INTEGER {undefined(1), on(2), off(3)}read-writecurrent
dtmbLocalizationTxAddress
OBJECT-TYPE
Description.
1.3.6.1.4.1.2566.127.1.2.216.12.1.2.5.1.2Unsigned32 (0..65535)read-writecurrent
dtmbOutput
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.1.3
dtmbOutModulationTable
OBJECT-TYPE
Currently active DTMB modulation parameters.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1not-accessiblecurrent
dtmbOutModulationEntry
OBJECT-TYPE
An entry in the dtmbOutModulationTable.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1not-accessiblecurrent
dtmbOutModulationChannelBandwidth
OBJECT-TYPE
Channel bandwidth occupied by the DTMB signal in the frequency spectrum. 6 MHz, 7 MHz or 8 MHz can be set. The choice depends on the required bandwidth of the channel to be transmitted.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.3DtmbChannelBandwidthread-onlycurrent
dtmbOutModulationGuardInterval
OBJECT-TYPE
Padding mode for the guard interval. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.5DtmbGuardIntervalread-onlycurrent
dtmbOutModulationConstellation
OBJECT-TYPE
Shows the modulation mode. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.6DtmbModulationread-onlycurrent
dtmbOutModulationCodeRate
OBJECT-TYPE
Shows the code rate. The code rate is used to set the ratio of information data to (error correction values + information data). 4/10 provides the greatest error correction and the lowest data transfer rate 8/10 provides the lowest error correction and the greatest data transfer rate. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.7DtmbCodeRateread-onlycurrent
dtmbOutModulationTimeInterleaver
OBJECT-TYPE
Shows the mode for the time interleaver. The time interleaver distributes the payload data over many symbols in order to reduce noise sensitivity. The setting 720 symbols (s720-3) is recommended for a high error tolerance. If, on the other hand, the resulting delay is to be kept short, the setting 240 symbols (s240-2) is more suitable. The value can be changed if Manual was selected as the TPS source.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.8INTEGER {off(2), s240(3), s720(4)}read-onlycurrent
dtmbOutModulationCarrierMode
OBJECT-TYPE
Shows whether the signal should be transmitted in Single Carrier Mode (previously: ADTB-T) or in Multicarrier Mode (previously: DMB-T) with 3780 single carriers.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.10INTEGER {single(2), multi(3)}read-onlycurrent
dtmbOutModulationDualPilotTone
OBJECT-TYPE
Shows whether two additional pilot signals are to be inserted into the spectrum. The pilots are at +/- half symbol rate. This parameter is effective only if Carrier Mode= Single has been selected.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.11SwitchOnOffread-onlycurrent
dtmbOutModulationGuardIntervalPN
OBJECT-TYPE
Shows which PN sequence (pseudo random noise sequence) is used for the guard interval. Constant (3): The PN sequence Index 0 is always used Variable (2): All PN sequences will be used.
1.3.6.1.4.1.2566.127.1.2.216.12.1.3.1.1.12INTEGER {variable(2), constant(3)}read-onlycurrent
rsXx9DtmbConformance
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.2
rsXx9DtmbCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.2.1
rsXx9DtmbGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2566.127.1.2.216.12.2.2

Notifications

NameOIDStatus
dtmbEncoderSummary
NOTIFICATION-TYPE
Encoder summary state. Possible values: off(2) fault(3) warning(4) ok(5) Notification class: fault
1.3.6.1.4.1.2566.127.1.2.216.12.0.1current
dtmbManualConfiguration
NOTIFICATION-TYPE
Indicates whether the configured DTMB configuration is consistent and valid over all three layers. If an error is displayed, check whether the sum of all segments over the three layers is exactly 13. Possible values: off(2) - warning(4) - not valid ok(5) - valid Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.12.0.2current
dtmbActiveConfiguration
NOTIFICATION-TYPE
Indicates whether the active DTMB configuration is consistent and valid over all three layers. If an error is displayed, check whether the sum of all segments over the three layers is exactly 13. Possible values: off(2) - warning(4) - not valid ok(5) - valid Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.12.0.3current
dtmbTest
NOTIFICATION-TYPE
One of the test signals is activated. If a test signal is activated, decoding of the transmitted signal by the transmitter will not be possible. Possible values: off(2) - no test signal generation warning(4) - test signal generation is activated Notification class: warning
1.3.6.1.4.1.2566.127.1.2.216.12.0.4current

Conformance

NameOIDStatus
dtmbBasicCompliance
MODULE-COMPLIANCE
The compliance statement for XX9000 DTMB encoding.
1.3.6.1.4.1.2566.127.1.2.216.12.2.1.1current
dtmbObjBasic
OBJECT-GROUP
Basic DTMB objects group.
1.3.6.1.4.1.2566.127.1.2.216.12.2.2.1current
dtmbNotifyBasic
NOTIFICATION-GROUP
General DTMB notifications.
1.3.6.1.4.1.2566.127.1.2.216.12.2.2.2current
dtmbObjBasicObsolete
OBJECT-GROUP
absoleted DTMB objects group.
1.3.6.1.4.1.2566.127.1.2.216.12.2.2.3obsolete