RS-232-MIB
- Registered at
- 1.3.6.1.2.1.10.33
- Last updated
- 1994-05-26 17:00
- Organization
- IETF Character MIB Working Group
- Namespace
- standard
- Source file
RS-232-MIB- Digest
sha256:fb0cb08bd22ffed676c6843cbc8b4880423bd2dcae183a508d6edcc7b19a4d76
Description
The MIB module for RS-232-like hardware devices.
Contact
Bob Stewart Postal: Xyplex, Inc. 295 Foster Street Littleton, MA 01460 Tel: 508-952-4816 Fax: 508-952-4887 E-mail: rlstewart@eng.xyplex.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | InterfaceIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB RS-232-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rs232Number OBJECT-TYPE The number of ports (regardless of their current state) in the RS-232-like general port table. | 1.3.6.1.2.1.10.33.1 | Integer32 | read-only | current |
| rs232PortTable OBJECT-TYPE A list of port entries. The number of entries is given by the value of rs232Number. | 1.3.6.1.2.1.10.33.2 | not-accessible | current | |
| rs232PortEntry OBJECT-TYPE Status and parameter values for a port. | 1.3.6.1.2.1.10.33.2.1 | not-accessible | current | |
| rs232PortIndex OBJECT-TYPE The value of ifIndex for the port. By convention and if possible, hardware port numbers map directly to external connectors. The value for each port must remain constant at least from one re-initialization of the network management agent to the next. | 1.3.6.1.2.1.10.33.2.1.1 | InterfaceIndex | read-only | current |
| rs232PortType OBJECT-TYPE The port's hardware type. | 1.3.6.1.2.1.10.33.2.1.2 | INTEGER {other(1), rs232(2), rs422(3), rs423(4), v35(5), x21(6)} | read-only | current |
| rs232PortInSigNumber OBJECT-TYPE The number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can detect and that are useful to observe. | 1.3.6.1.2.1.10.33.2.1.3 | Integer32 | read-only | current |
| rs232PortOutSigNumber OBJECT-TYPE The number of output signals for the port in the output signal table (rs232PortOutSigTable). The table contains entries only for those signals the software can assert and that are useful to observe. | 1.3.6.1.2.1.10.33.2.1.4 | Integer32 | read-only | current |
| rs232PortInSpeed OBJECT-TYPE The port's input speed in bits per second. Note that non-standard values, such as 9612, are probably not allowed on most implementations. | 1.3.6.1.2.1.10.33.2.1.5 | Integer32 | read-write | current |
| rs232PortOutSpeed OBJECT-TYPE The port's output speed in bits per second. Note that non-standard values, such as 9612, are probably not allowed on most implementations. | 1.3.6.1.2.1.10.33.2.1.6 | Integer32 | read-write | current |
| rs232PortInFlowType OBJECT-TYPE The port's type of input flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals. | 1.3.6.1.2.1.10.33.2.1.7 | INTEGER {none(1), ctsRts(2), dsrDtr(3)} | read-write | current |
| rs232PortOutFlowType OBJECT-TYPE The port's type of output flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals. | 1.3.6.1.2.1.10.33.2.1.8 | INTEGER {none(1), ctsRts(2), dsrDtr(3)} | read-write | current |
| rs232AsyncPortTable OBJECT-TYPE A list of asynchronous port entries. Entries need not exist for synchronous ports. | 1.3.6.1.2.1.10.33.3 | not-accessible | current | |
| rs232AsyncPortEntry OBJECT-TYPE Status and parameter values for an asynchronous port. | 1.3.6.1.2.1.10.33.3.1 | not-accessible | current | |
| rs232AsyncPortIndex OBJECT-TYPE A unique value for each port. Its value is the same as rs232PortIndex for the port. | 1.3.6.1.2.1.10.33.3.1.1 | InterfaceIndex | read-only | current |
| rs232AsyncPortBits OBJECT-TYPE The port's number of bits in a character. | 1.3.6.1.2.1.10.33.3.1.2 | INTEGER (5..8) | read-write | current |
| rs232AsyncPortStopBits OBJECT-TYPE The port's number of stop bits. | 1.3.6.1.2.1.10.33.3.1.3 | INTEGER {one(1), two(2), oneAndHalf(3), dynamic(4)} | read-write | current |
| rs232AsyncPortParity OBJECT-TYPE The port's sense of a character parity bit. | 1.3.6.1.2.1.10.33.3.1.4 | INTEGER {none(1), odd(2), even(3), mark(4), space(5)} | read-write | current |
| rs232AsyncPortAutobaud OBJECT-TYPE A control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set values for speed, parity, and character size. As a result a network management system may temporarily observe values different from what was previously set. | 1.3.6.1.2.1.10.33.3.1.5 | INTEGER {enabled(1), disabled(2)} | read-write | current |
| rs232AsyncPortParityErrs OBJECT-TYPE Total number of characters with a parity error, input from the port since system re-initialization and while the port state was 'up' or 'test'. | 1.3.6.1.2.1.10.33.3.1.6 | Counter32 | read-only | current |
| rs232AsyncPortFramingErrs OBJECT-TYPE Total number of characters with a framing error, input from the port since system re-initialization and while the port state was 'up' or 'test'. | 1.3.6.1.2.1.10.33.3.1.7 | Counter32 | read-only | current |
| rs232AsyncPortOverrunErrs OBJECT-TYPE Total number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'. | 1.3.6.1.2.1.10.33.3.1.8 | Counter32 | read-only | current |
| rs232SyncPortTable OBJECT-TYPE A list of asynchronous port entries. Entries need not exist for synchronous ports. | 1.3.6.1.2.1.10.33.4 | not-accessible | current | |
| rs232SyncPortEntry OBJECT-TYPE Status and parameter values for a synchronous port. | 1.3.6.1.2.1.10.33.4.1 | not-accessible | current | |
| rs232SyncPortIndex OBJECT-TYPE A unique value for each port. Its value is the same as rs232PortIndex for the port. | 1.3.6.1.2.1.10.33.4.1.1 | InterfaceIndex | read-only | current |
| rs232SyncPortClockSource OBJECT-TYPE Source of the port's bit rate clock. 'split' means the tranmit clock is internal and the receive clock is external. | 1.3.6.1.2.1.10.33.4.1.2 | INTEGER {internal(1), external(2), split(3)} | read-write | current |
| rs232SyncPortFrameCheckErrs OBJECT-TYPE Total number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'. | 1.3.6.1.2.1.10.33.4.1.3 | Counter32 | read-only | current |
| rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE Total number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was not available to the transmitter in time. | 1.3.6.1.2.1.10.33.4.1.4 | Counter32 | read-only | current |
| rs232SyncPortReceiveOverrunErrs OBJECT-TYPE Total number of frames that failed to be received on the port since system re-initialization and while the port state was 'up' or 'test' because the receiver did not accept the data in time. | 1.3.6.1.2.1.10.33.4.1.5 | Counter32 | read-only | current |
| rs232SyncPortInterruptedFrames OBJECT-TYPE Total number of frames that failed to be received or transmitted on the port due to loss of modem signals since system re-initialization and while the port state was 'up' or 'test'. | 1.3.6.1.2.1.10.33.4.1.6 | Counter32 | read-only | current |
| rs232SyncPortAbortedFrames OBJECT-TYPE Number of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'. | 1.3.6.1.2.1.10.33.4.1.7 | Counter32 | read-only | current |
| rs232SyncPortRole OBJECT-TYPE The role the device is playing that is using this port. dte means the device is performing the role of data terminal equipment dce means the device is performing the role of data circuit-terminating equipment. | 1.3.6.1.2.1.10.33.4.1.8 | INTEGER {dte(1), dce(2)} | read-write | current |
| rs232SyncPortEncoding OBJECT-TYPE The bit stream encoding technique that is in effect for this port. nrz for Non-Return to Zero encoding nrzi for Non-Return to Zero Inverted encoding. | 1.3.6.1.2.1.10.33.4.1.9 | INTEGER {nrz(1), nrzi(2)} | read-write | current |
| rs232SyncPortRTSControl OBJECT-TYPE The method used to control the Request To Send (RTS) signal. controlled when the DTE is asserts RTS each time data needs to be transmitted and drops RTS at some point after data transmission begins. If rs232SyncPortRole is 'dte', the RTS is an output signal. The device will issue a RTS and wait for a CTS from the DCE before starting to transmit. If rs232SyncPortRole is 'dce', the RTS is an input signal. The device will issue a CTS only after having received RTS and waiting the rs232SyncPortRTSCTSDelay interval. constant when the DTE constantly asserts RTS. | 1.3.6.1.2.1.10.33.4.1.10 | INTEGER {controlled(1), constant(2)} | read-write | current |
| rs232SyncPortRTSCTSDelay OBJECT-TYPE The interval (in milliseconds) that the DCE must wait after it sees RTS asserted before asserting CTS. This object exists in support of older synchronous devices that cannot recognize CTS within a certain interval after it asserts RTS. | 1.3.6.1.2.1.10.33.4.1.11 | Integer32 | read-write | current |
| rs232SyncPortMode OBJECT-TYPE The mode of operation of the port with respect to the direction and simultaneity of data transfer. fdx when frames on the data link can be transmitted and received at the same time hdx when frames can either be received from the data link or transmitted onto the data link but not at the same time. simplex-receive when frames can only be received on this data link. simplex-send when frames can only be sent on this data link. | 1.3.6.1.2.1.10.33.4.1.12 | INTEGER {fdx(1), hdx(2), simplex-receive(3), simplex-send(4)} | read-write | current |
| rs232SyncPortIdlePattern OBJECT-TYPE The bit pattern used to indicate an idle line. | 1.3.6.1.2.1.10.33.4.1.13 | INTEGER {mark(1), space(2)} | read-write | current |
| rs232SyncPortMinFlags OBJECT-TYPE The minimum number of flag patterns this port needs in order to recognize the end of one frame and the start of the next. Plausible values are 1 and 2. | 1.3.6.1.2.1.10.33.4.1.14 | Integer32 | read-write | current |
| rs232InSigTable OBJECT-TYPE A list of port input control signal entries implemented and visible to the software on the port, and useful to monitor. | 1.3.6.1.2.1.10.33.5 | not-accessible | current | |
| rs232InSigEntry OBJECT-TYPE Input control signal status for a hardware port. | 1.3.6.1.2.1.10.33.5.1 | not-accessible | current | |
| rs232InSigPortIndex OBJECT-TYPE The value of rs232PortIndex for the port to which this entry belongs. | 1.3.6.1.2.1.10.33.5.1.1 | InterfaceIndex | read-only | current |
| rs232InSigName OBJECT-TYPE Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector | 1.3.6.1.2.1.10.33.5.1.2 | INTEGER {rts(1), cts(2), dsr(3), dtr(4), ri(5), dcd(6), sq(7), srs(8), srts(9), scts(10), sdcd(11)} | read-only | current |
| rs232InSigState OBJECT-TYPE The current signal state. | 1.3.6.1.2.1.10.33.5.1.3 | INTEGER {none(1), on(2), off(3)} | read-only | current |
| rs232InSigChanges OBJECT-TYPE The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'. | 1.3.6.1.2.1.10.33.5.1.4 | Counter32 | read-only | current |
| rs232OutSigTable OBJECT-TYPE A list of port output control signal entries implemented and visible to the software on the port, and useful to monitor. | 1.3.6.1.2.1.10.33.6 | not-accessible | current | |
| rs232OutSigEntry OBJECT-TYPE Output control signal status for a hardware port. | 1.3.6.1.2.1.10.33.6.1 | not-accessible | current | |
| rs232OutSigPortIndex OBJECT-TYPE The value of rs232PortIndex for the port to which this entry belongs. | 1.3.6.1.2.1.10.33.6.1.1 | InterfaceIndex | read-only | current |
| rs232OutSigName OBJECT-TYPE Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector | 1.3.6.1.2.1.10.33.6.1.2 | INTEGER {rts(1), cts(2), dsr(3), dtr(4), ri(5), dcd(6), sq(7), srs(8), srts(9), scts(10), sdcd(11)} | read-only | current |
| rs232OutSigState OBJECT-TYPE The current signal state. | 1.3.6.1.2.1.10.33.6.1.3 | INTEGER {none(1), on(2), off(3)} | read-only | current |
| rs232OutSigChanges OBJECT-TYPE The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'. | 1.3.6.1.2.1.10.33.6.1.4 | Counter32 | read-only | current |
| rs232Conformance OBJECT-IDENTITY | 1.3.6.1.2.1.10.33.7 | |||
| rs232Groups OBJECT-IDENTITY | 1.3.6.1.2.1.10.33.7.1 | |||
| rs232Compliances OBJECT-IDENTITY | 1.3.6.1.2.1.10.33.7.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| rs232Group OBJECT-GROUP A collection of objects providing information applicable to all RS-232-like interfaces. | 1.3.6.1.2.1.10.33.7.1.1 | current |
| rs232AsyncGroup OBJECT-GROUP A collection of objects providing information applicable to asynchronous RS-232-like interfaces. | 1.3.6.1.2.1.10.33.7.1.2 | current |
| rs232SyncGroup OBJECT-GROUP A collection of objects providing information applicable to synchronous RS-232-like interfaces. | 1.3.6.1.2.1.10.33.7.1.3 | current |
| rs232SyncSDLCGroup OBJECT-GROUP A collection of objects providing information applicable to synchronous RS-232-like interfaces running SDLC. | 1.3.6.1.2.1.10.33.7.1.4 | current |
| rs232Compliance MODULE-COMPLIANCE The compliance statement for SNMPv2 entities which have RS-232-like hardware interfaces. | 1.3.6.1.2.1.10.33.7.2.1 | current |