ROOMALERT11E-MIB
- Registered at
- 1.3.6.1.4.1.20916
- Namespace
- avtech
- Source file
ROOMALERT11E-MIB- Digest
sha256:5afd439b49a7eeaa329cf5b27270214754201618e3931e5112c2c311e0d53e8d
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ROOMALERT11E-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Under this module's arcs
Where the registration tree carries on below this module.
| Arc | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.20916.1 | products |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| avtech OBJECT-IDENTITY | 1.3.6.1.4.1.20916 | |||
| products OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1 | |||
| roomalert11E OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3 | |||
| sensors OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.1 | |||
| channel1 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.1.1 | |||
| sensor1_1 OBJECT-TYPE The reading for internal switch sensor 1 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.1 | INTEGER (0..1) | read-only | mandatory |
| sensor1_2 OBJECT-TYPE The reading for internal switch sensor 2 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.2 | INTEGER (0..1) | read-only | mandatory |
| sensor1_3 OBJECT-TYPE The reading for internal switch sensor 3 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.3 | INTEGER (0..1) | read-only | mandatory |
| sensor1_4 OBJECT-TYPE The reading for internal switch sensor 4 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.4 | INTEGER (0..1) | read-only | mandatory |
| sensor1_5 OBJECT-TYPE The reading for internal switch sensor 5 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.5 | INTEGER (0..1) | read-only | mandatory |
| sensor1_6 OBJECT-TYPE The reading for internal switch sensor 6 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.6 | INTEGER (0..1) | read-only | mandatory |
| sensor1_7 OBJECT-TYPE The reading for internal switch sensor 7 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.7 | INTEGER (0..1) | read-only | mandatory |
| sensor1_8 OBJECT-TYPE The reading for internal switch sensor 8 (0 = OPEN, 1 = CLOSED). | 1.3.6.1.4.1.20916.1.3.1.1.8 | INTEGER (0..1) | read-only | mandatory |
| switch_label_1 OBJECT-TYPE The label for switch sensor 1 | 1.3.6.1.4.1.20916.1.3.1.1.9 | OCTET STRING | read-only | mandatory |
| switch_label_2 OBJECT-TYPE The label for switch sensor 2 | 1.3.6.1.4.1.20916.1.3.1.1.10 | OCTET STRING | read-only | mandatory |
| switch_label_3 OBJECT-TYPE The label for switch sensor 3 | 1.3.6.1.4.1.20916.1.3.1.1.11 | OCTET STRING | read-only | mandatory |
| switch_label_4 OBJECT-TYPE The label for switch sensor 4 | 1.3.6.1.4.1.20916.1.3.1.1.12 | OCTET STRING | read-only | mandatory |
| switch_label_5 OBJECT-TYPE The label for switch sensor 5 | 1.3.6.1.4.1.20916.1.3.1.1.13 | OCTET STRING | read-only | mandatory |
| switch_label_6 OBJECT-TYPE The label for switch sensor 6 | 1.3.6.1.4.1.20916.1.3.1.1.14 | OCTET STRING | read-only | mandatory |
| switch_label_7 OBJECT-TYPE The label for switch sensor 7 | 1.3.6.1.4.1.20916.1.3.1.1.15 | OCTET STRING | read-only | mandatory |
| switch_label_8 OBJECT-TYPE The label for switch sensor 8 | 1.3.6.1.4.1.20916.1.3.1.1.16 | OCTET STRING | read-only | mandatory |
| channel2 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.1.2 | |||
| sensor2_1 OBJECT-TYPE The reading for sensor 2-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius. | 1.3.6.1.4.1.20916.1.3.1.2.1 | INTEGER (0..65535) | read-only | mandatory |
| sensor2_2 OBJECT-TYPE The reading for sensor 2-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit. | 1.3.6.1.4.1.20916.1.3.1.2.2 | INTEGER (0..65535) | read-only | mandatory |
| sensor2_3 OBJECT-TYPE The reading for sensor 2-3. If temp/humidity sensor is connected, value will be current %RH. | 1.3.6.1.4.1.20916.1.3.1.2.3 | INTEGER (0..65535) | read-only | mandatory |
| sensor2_4 OBJECT-TYPE The reading for sensor 2-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit. | 1.3.6.1.4.1.20916.1.3.1.2.4 | INTEGER (0..65535) | read-only | mandatory |
| sensor2_5 OBJECT-TYPE The reading for sensor 2-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius. | 1.3.6.1.4.1.20916.1.3.1.2.5 | INTEGER (0..65535) | read-only | mandatory |
| sensor2_6_label OBJECT-TYPE The label of this sensor | 1.3.6.1.4.1.20916.1.3.1.2.6 | OCTET STRING | read-only | mandatory |
| channel3 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.1.3 | |||
| sensor3_1 OBJECT-TYPE The reading for sensor 3-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius. | 1.3.6.1.4.1.20916.1.3.1.3.1 | INTEGER (0..65535) | read-only | mandatory |
| sensor3_2 OBJECT-TYPE The reading for sensor 3-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit. | 1.3.6.1.4.1.20916.1.3.1.3.2 | INTEGER (0..65535) | read-only | mandatory |
| sensor3_3 OBJECT-TYPE The reading for sensor 3-3. If temp/humidity sensor is connected, value will be current %RH. | 1.3.6.1.4.1.20916.1.3.1.3.3 | INTEGER (0..65535) | read-only | mandatory |
| sensor3_4 OBJECT-TYPE The reading for sensor 3-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit. | 1.3.6.1.4.1.20916.1.3.1.3.4 | INTEGER (0..65535) | read-only | mandatory |
| sensor3_5 OBJECT-TYPE The reading for sensor 3-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius. | 1.3.6.1.4.1.20916.1.3.1.3.5 | INTEGER (0..65535) | read-only | mandatory |
| sensor3_6_label OBJECT-TYPE The label of this sensor | 1.3.6.1.4.1.20916.1.3.1.3.6 | OCTET STRING | read-only | mandatory |
| channel4 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.1.4 | |||
| sensor4_1 OBJECT-TYPE The reading for sensor 4-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius. | 1.3.6.1.4.1.20916.1.3.1.4.1 | INTEGER (0..65535) | read-only | mandatory |
| sensor4_2 OBJECT-TYPE The reading for sensor 4-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit. | 1.3.6.1.4.1.20916.1.3.1.4.2 | INTEGER (0..65535) | read-only | mandatory |
| sensor4_3 OBJECT-TYPE The reading for sensor 4-3. If temp/humidity sensor is connected, value will be current %RH. | 1.3.6.1.4.1.20916.1.3.1.4.3 | INTEGER (0..65535) | read-only | mandatory |
| sensor4_4 OBJECT-TYPE The reading for sensor 4-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit. | 1.3.6.1.4.1.20916.1.3.1.4.4 | INTEGER (0..65535) | read-only | mandatory |
| sensor4_5 OBJECT-TYPE The reading for sensor 4-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius. | 1.3.6.1.4.1.20916.1.3.1.4.5 | INTEGER (0..65535) | read-only | mandatory |
| sensor4_6_label OBJECT-TYPE The label of this sensor | 1.3.6.1.4.1.20916.1.3.1.4.6 | OCTET STRING | read-only | mandatory |
| traps OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.2 | |||
| alarm1 OBJECT-TYPE Alarm for sensor channel 1. The binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary. | 1.3.6.1.4.1.20916.1.3.2.1 | INTEGER (0..255) | read-only | mandatory |
| alarm2 OBJECT-TYPE Alarm for sensor channel 2. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary. | 1.3.6.1.4.1.20916.1.3.2.2 | INTEGER (0..255) | read-only | mandatory |
| alarm3 OBJECT-TYPE Alarm for sensor channel 3. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary. | 1.3.6.1.4.1.20916.1.3.2.3 | INTEGER (0..255) | read-only | mandatory |
| alarm4 OBJECT-TYPE Alarm for sensor channel 4. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary. | 1.3.6.1.4.1.20916.1.3.2.4 | INTEGER (0..255) | read-only | mandatory |
| alarmMessage1 OBJECT-TYPE Alarm Message from sensor channel 1 (Internal) | 1.3.6.1.4.1.20916.1.3.2.5 | OCTET STRING | read-only | mandatory |
| alarmMessage2 OBJECT-TYPE Alarm Message from sensor channel 2 (External) | 1.3.6.1.4.1.20916.1.3.2.6 | OCTET STRING | read-only | mandatory |
| alarmMessage3 OBJECT-TYPE Alarm Message from sensor channel 3 (External) | 1.3.6.1.4.1.20916.1.3.2.7 | OCTET STRING | read-only | mandatory |
| alarmMessage4 OBJECT-TYPE Alarm Message from sensor channel 4 (External) | 1.3.6.1.4.1.20916.1.3.2.8 | OCTET STRING | read-only | mandatory |
| thresholds OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.3 | |||
| channels OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.3.1 | |||
| channels1 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.3.1.1 | |||
| threshold1_1 OBJECT-TYPE Threshold 1 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.1 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_2 OBJECT-TYPE Threshold 2 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.2 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_3 OBJECT-TYPE Threshold 3 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.3 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_4 OBJECT-TYPE Threshold 4 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.4 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_5 OBJECT-TYPE Threshold 5 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.5 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_6 OBJECT-TYPE Threshold 6 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.6 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_7 OBJECT-TYPE Threshold 7 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.7 | INTEGER (0..65535) | read-only | mandatory |
| threshold1_8 OBJECT-TYPE Threshold 8 defined for Channel 1 | 1.3.6.1.4.1.20916.1.3.3.1.1.8 | INTEGER (0..65535) | read-only | mandatory |
| channels2 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.3.1.2 | |||
| threshold2_1 OBJECT-TYPE Threshold 1 defined for Channel 2 | 1.3.6.1.4.1.20916.1.3.3.1.2.1 | INTEGER (0..65535) | read-only | mandatory |
| threshold2_2 OBJECT-TYPE Threshold 2 defined for Channel 2 | 1.3.6.1.4.1.20916.1.3.3.1.2.2 | INTEGER (0..65535) | read-only | mandatory |
| threshold2_3 OBJECT-TYPE Threshold 3 defined for Channel 2 | 1.3.6.1.4.1.20916.1.3.3.1.2.3 | INTEGER (0..65535) | read-only | mandatory |
| threshold2_4 OBJECT-TYPE Threshold 4 defined for Channel 2 | 1.3.6.1.4.1.20916.1.3.3.1.2.4 | INTEGER (0..65535) | read-only | mandatory |
| channels3 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.3.1.3 | |||
| threshold3_1 OBJECT-TYPE Threshold 1 defined for Channel 3 | 1.3.6.1.4.1.20916.1.3.3.1.3.1 | INTEGER (0..65535) | read-only | mandatory |
| threshold3_2 OBJECT-TYPE Threshold 2 defined for Channel 3 | 1.3.6.1.4.1.20916.1.3.3.1.3.2 | INTEGER (0..65535) | read-only | mandatory |
| threshold3_3 OBJECT-TYPE Threshold 3 defined for Channel 3 | 1.3.6.1.4.1.20916.1.3.3.1.3.3 | INTEGER (0..65535) | read-only | mandatory |
| threshold3_4 OBJECT-TYPE Threshold 4 defined for Channel 3 | 1.3.6.1.4.1.20916.1.3.3.1.3.4 | INTEGER (0..65535) | read-only | mandatory |
| channels4 OBJECT-IDENTITY | 1.3.6.1.4.1.20916.1.3.3.1.4 | |||
| threshold4_1 OBJECT-TYPE Threshold 1 defined for Channel 4 | 1.3.6.1.4.1.20916.1.3.3.1.4.1 | INTEGER (0..65535) | read-only | mandatory |
| threshold4_2 OBJECT-TYPE Threshold 2 defined for Channel 4 | 1.3.6.1.4.1.20916.1.3.3.1.4.2 | INTEGER (0..65535) | read-only | mandatory |
| threshold4_3 OBJECT-TYPE Threshold 3 defined for Channel 4 | 1.3.6.1.4.1.20916.1.3.3.1.4.3 | INTEGER (0..65535) | read-only | mandatory |
| threshold4_4 OBJECT-TYPE Threshold 4 defined for Channel 4 | 1.3.6.1.4.1.20916.1.3.3.1.4.4 | INTEGER (0..65535) | read-only | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| tempAlarm1_11e NOTIFICATION-TYPE A tempAlarm1 trap signifies that the current temperature on external sensor 1 is outside the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.1 | |
| room_alert_11E_SNMP_trap NOTIFICATION-TYPE A Room Alert 11E SNMP Trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmMessage variable. | 1.3.6.1.4.1.20916.1.3.0.2 | |
| tempAlarm2_11e NOTIFICATION-TYPE A tempAlarm2 trap signifies that the current temperature on external sensor 2 is outside the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.3 | |
| tempClear2_11e NOTIFICATION-TYPE A tempClear2 trap signifies that the current temperature on external sensor 2 has returned to a normal condition and is within the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.4 | |
| tempAlarm3_11e NOTIFICATION-TYPE A tempAlarm3 trap signifies that the current temperature on external sensor 3 is outside the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.5 | |
| tempClear3_11e NOTIFICATION-TYPE A tempClear3 trap signifies that the current temperature on external sensor 3 has returned to a normal condition and is within the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.6 | |
| humidityAlarm1_11e NOTIFICATION-TYPE A humidityAlarm1 trap signifies that the current humidity on external sensor 1 is outside the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.7 | |
| humidityClear1_11e NOTIFICATION-TYPE A humidityClear1 trap signifies that the current humidity on external sensor 1 has returned to a normal condition and is within the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.8 | |
| humidityAlarm2_11e NOTIFICATION-TYPE A humidityAlarm2 trap signifies that the current humidity on external sensor 2 is outside the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.9 | |
| humidityClear2_11e NOTIFICATION-TYPE A humidityClear2 trap signifies that the current humidity on external sensor 2 has returned to a normal condition and is within the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.10 | |
| humidityAlarm3_11e NOTIFICATION-TYPE A humidityAlarm3 trap signifies that the current humidity on external sensor 3 is outside the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.11 | |
| humidityClear3_11e NOTIFICATION-TYPE A humidityClear3 trap signifies that the current humidity on external sensor 3 has returned to a normal condition and is within the defined high or low threshold. | 1.3.6.1.4.1.20916.1.3.0.12 | |
| switchAlarm1_11e NOTIFICATION-TYPE A switchAlarm1 trap signifies that switch sensor 1 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.13 | |
| switchClear1_11e NOTIFICATION-TYPE A switchClear1 trap signifies that the switch sensor 1 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.14 | |
| switchAlarm2_11e NOTIFICATION-TYPE A switchAlarm2 trap signifies that switch sensor 2 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.15 | |
| switchClear2_11e NOTIFICATION-TYPE A switchClear2 trap signifies that the switch sensor 2 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.16 | |
| switchAlarm3_11e NOTIFICATION-TYPE A switchAlarm1 trap signifies that switch sensor 1 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.17 | |
| switchClear3_11e NOTIFICATION-TYPE A switchClear3 trap signifies that the switch sensor 3 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.18 | |
| switchAlarm4_11e NOTIFICATION-TYPE A switchAlarm4 trap signifies that switch sensor 4 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.19 | |
| switchClear4_11e NOTIFICATION-TYPE A switchClear4 trap signifies that the switch sensor 4 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.20 | |
| switchAlarm5_11e NOTIFICATION-TYPE A switchAlarm5 trap signifies that switch sensor 5 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.21 | |
| switchClear5_11e NOTIFICATION-TYPE A switchClear5 trap signifies that the switch sensor 5 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.22 | |
| switchAlarm6_11e NOTIFICATION-TYPE A switchAlarm6 trap signifies that switch sensor 6 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.23 | |
| switchClear6_11e NOTIFICATION-TYPE A switchClear6 trap signifies that the switch sensor 6 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.24 | |
| switchAlarm7_11e NOTIFICATION-TYPE A switchAlarm7 trap signifies that switch sensor 7 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.25 | |
| switchClear7_11e NOTIFICATION-TYPE A switchClear7 trap signifies that the switch sensor 7 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.26 | |
| switchAlarm8_11e NOTIFICATION-TYPE A switchAlarm8 trap signifies that switch sensor 8 is in an alarm state. | 1.3.6.1.4.1.20916.1.3.0.27 | |
| switchClear8_11e NOTIFICATION-TYPE A switchClear8 trap signifies that the switch sensor 8 has returned to a normal state. | 1.3.6.1.4.1.20916.1.3.0.28 |