RFC1382-MIB

Registered at
1.3.6.1.2.1.10.5
Namespace
standard
Source file
RFC1382-MIB
Digest
sha256:61920d86d84c9f6f0aafd667046cbdfadc720508802c2abfbb3c1cd75d3c9e21

Imports

FromSymbols
RFC1271-MIBEntryStatus
RFC1381-MIBIfIndexType, PositiveInteger
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, iso, transmission
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

1 module(s) in this corpus import this one.

Load order

Every file a consumer needs in order to load this module, dependencies first.

RFC1158-MIB
RFC1271-MIB
RFC1381-MIB
RFC1382-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
X121Address
type

Objects

NameOIDSyntaxAccessStatus
x25
OBJECT-IDENTITY
1.3.6.1.2.1.10.5
x25AdmnTable
OBJECT-TYPE
This table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have corresponding objects in the x25OperTable. This table contains the values as last set by the administrator. The x25OperTable contains the values actually in use by an X.25 PLE. Changing an administrative value may or may not change a current operating value. The operating value may not change until the interface is restarted. Some implementations may change the values immediately upon changing the administrative table. All implementations are required to load the values from the administrative table when initializing a PLE.
1.3.6.1.2.1.10.5.1not-accessiblemandatory
x25AdmnEntry
OBJECT-TYPE
Entries of x25AdmnTable.
1.3.6.1.2.1.10.5.1.1not-accessiblemandatory
x25AdmnIndex
OBJECT-TYPE
The ifIndex value for the X.25 Interface.
1.3.6.1.2.1.10.5.1.1.1IfIndexTyperead-onlymandatory
x25AdmnInterfaceMode
OBJECT-TYPE
Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation.
1.3.6.1.2.1.10.5.1.1.2INTEGER {dte(1), dce(2), dxe(3)}read-writemandatory
x25AdmnMaxActiveCircuits
OBJECT-TYPE
The maximum number of circuits this PLE can support; including PVCs.
1.3.6.1.2.1.10.5.1.1.3INTEGER (0..4096)read-writemandatory
x25AdmnPacketSequencing
OBJECT-TYPE
The modulus of the packet sequence number space.
1.3.6.1.2.1.10.5.1.1.4INTEGER {modulo8(1), modulo128(2)}read-writemandatory
x25AdmnRestartTimer
OBJECT-TYPE
The T20 restart timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.5PositiveIntegerread-writemandatory
x25AdmnCallTimer
OBJECT-TYPE
The T21 Call timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.6PositiveIntegerread-writemandatory
x25AdmnResetTimer
OBJECT-TYPE
The T22 Reset timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.7PositiveIntegerread-writemandatory
x25AdmnClearTimer
OBJECT-TYPE
The T23 Clear timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.8PositiveIntegerread-writemandatory
x25AdmnWindowTimer
OBJECT-TYPE
The T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use.
1.3.6.1.2.1.10.5.1.1.9PositiveIntegerread-writemandatory
x25AdmnDataRxmtTimer
OBJECT-TYPE
The T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
1.3.6.1.2.1.10.5.1.1.10PositiveIntegerread-writemandatory
x25AdmnInterruptTimer
OBJECT-TYPE
The T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use.
1.3.6.1.2.1.10.5.1.1.11PositiveIntegerread-writemandatory
x25AdmnRejectTimer
OBJECT-TYPE
The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
1.3.6.1.2.1.10.5.1.1.12PositiveIntegerread-writemandatory
x25AdmnRegistrationRequestTimer
OBJECT-TYPE
The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
1.3.6.1.2.1.10.5.1.1.13PositiveIntegerread-writemandatory
x25AdmnMinimumRecallTimer
OBJECT-TYPE
Minimum time interval between unsuccessful call attempts in milliseconds.
1.3.6.1.2.1.10.5.1.1.14PositiveIntegerread-writemandatory
x25AdmnRestartCount
OBJECT-TYPE
The R20 restart retransmission count.
1.3.6.1.2.1.10.5.1.1.15INTEGER (0..65535)read-writemandatory
x25AdmnResetCount
OBJECT-TYPE
The r22 Reset retransmission count.
1.3.6.1.2.1.10.5.1.1.16INTEGER (0..65535)read-writemandatory
x25AdmnClearCount
OBJECT-TYPE
The r23 Clear retransmission count.
1.3.6.1.2.1.10.5.1.1.17INTEGER (0..65535)read-writemandatory
x25AdmnDataRxmtCount
OBJECT-TYPE
The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use.
1.3.6.1.2.1.10.5.1.1.18INTEGER (0..65535)read-writemandatory
x25AdmnRejectCount
OBJECT-TYPE
The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use.
1.3.6.1.2.1.10.5.1.1.19INTEGER (0..65535)read-writemandatory
x25AdmnRegistrationRequestCount
OBJECT-TYPE
The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use.
1.3.6.1.2.1.10.5.1.1.20INTEGER (0..65535)read-writemandatory
x25AdmnNumberPVCs
OBJECT-TYPE
The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
1.3.6.1.2.1.10.5.1.1.21INTEGER (0..4096)read-writemandatory
x25AdmnDefCallParamId
OBJECT-TYPE
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE.
1.3.6.1.2.1.10.5.1.1.22OBJECT IDENTIFIERread-writemandatory
x25AdmnLocalAddress
OBJECT-TYPE
The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
1.3.6.1.2.1.10.5.1.1.23X121Addressread-writemandatory
x25AdmnProtocolVersionSupported
OBJECT-TYPE
Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
1.3.6.1.2.1.10.5.1.1.24OBJECT IDENTIFIERread-writemandatory
x25OperTable
OBJECT-TYPE
The operation parameters in use by the X.25 PLE.
1.3.6.1.2.1.10.5.2not-accessiblemandatory
x25OperEntry
OBJECT-TYPE
Entries of x25OperTable.
1.3.6.1.2.1.10.5.2.1not-accessiblemandatory
x25OperIndex
OBJECT-TYPE
The ifIndex value for the X.25 interface.
1.3.6.1.2.1.10.5.2.1.1IfIndexTyperead-onlymandatory
x25OperInterfaceMode
OBJECT-TYPE
Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place.
1.3.6.1.2.1.10.5.2.1.2INTEGER {dte(1), dce(2), dxe(3)}read-onlymandatory
x25OperMaxActiveCircuits
OBJECT-TYPE
Maximum number of circuits this PLE can support.
1.3.6.1.2.1.10.5.2.1.3INTEGER (0..4096)read-onlymandatory
x25OperPacketSequencing
OBJECT-TYPE
The modulus of the packet sequence number space.
1.3.6.1.2.1.10.5.2.1.4INTEGER {modulo8(1), modulo128(2)}read-onlymandatory
x25OperRestartTimer
OBJECT-TYPE
The T20 restart timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.5PositiveIntegerread-onlymandatory
x25OperCallTimer
OBJECT-TYPE
The T21 Call timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.6PositiveIntegerread-onlymandatory
x25OperResetTimer
OBJECT-TYPE
The T22 Reset timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.7PositiveIntegerread-onlymandatory
x25OperClearTimer
OBJECT-TYPE
The T23 Clear timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.8PositiveIntegerread-onlymandatory
x25OperWindowTimer
OBJECT-TYPE
The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use.
1.3.6.1.2.1.10.5.2.1.9PositiveIntegerread-onlymandatory
x25OperDataRxmtTimer
OBJECT-TYPE
The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
1.3.6.1.2.1.10.5.2.1.10PositiveIntegerread-onlymandatory
x25OperInterruptTimer
OBJECT-TYPE
The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used.
1.3.6.1.2.1.10.5.2.1.11PositiveIntegerread-onlymandatory
x25OperRejectTimer
OBJECT-TYPE
The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
1.3.6.1.2.1.10.5.2.1.12PositiveIntegerread-onlymandatory
x25OperRegistrationRequestTimer
OBJECT-TYPE
The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
1.3.6.1.2.1.10.5.2.1.13PositiveIntegerread-onlymandatory
x25OperMinimumRecallTimer
OBJECT-TYPE
Minimum time interval between unsuccessful call attempts in milliseconds.
1.3.6.1.2.1.10.5.2.1.14PositiveIntegerread-onlymandatory
x25OperRestartCount
OBJECT-TYPE
The R20 restart retransmission count.
1.3.6.1.2.1.10.5.2.1.15INTEGER (0..65535)read-onlymandatory
x25OperResetCount
OBJECT-TYPE
The r22 Reset retransmission count.
1.3.6.1.2.1.10.5.2.1.16INTEGER (0..65535)read-onlymandatory
x25OperClearCount
OBJECT-TYPE
The r23 Clear retransmission count.
1.3.6.1.2.1.10.5.2.1.17INTEGER (0..65535)read-onlymandatory
x25OperDataRxmtCount
OBJECT-TYPE
The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use.
1.3.6.1.2.1.10.5.2.1.18INTEGER (0..65535)read-onlymandatory
x25OperRejectCount
OBJECT-TYPE
The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use.
1.3.6.1.2.1.10.5.2.1.19INTEGER (0..65535)read-onlymandatory
x25OperRegistrationRequestCount
OBJECT-TYPE
The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use.
1.3.6.1.2.1.10.5.2.1.20INTEGER (0..65535)read-onlymandatory
x25OperNumberPVCs
OBJECT-TYPE
The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
1.3.6.1.2.1.10.5.2.1.21INTEGER (0..4096)read-onlymandatory
x25OperDefCallParamId
OBJECT-TYPE
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE.
1.3.6.1.2.1.10.5.2.1.22OBJECT IDENTIFIERread-onlymandatory
x25OperLocalAddress
OBJECT-TYPE
The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
1.3.6.1.2.1.10.5.2.1.23X121Addressread-onlymandatory
x25OperDataLinkId
OBJECT-TYPE
This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE.
1.3.6.1.2.1.10.5.2.1.24OBJECT IDENTIFIERread-onlymandatory
x25OperProtocolVersionSupported
OBJECT-TYPE
Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
1.3.6.1.2.1.10.5.2.1.25OBJECT IDENTIFIERread-onlymandatory
x25StatTable
OBJECT-TYPE
Statistics information about this X.25 PLE.
1.3.6.1.2.1.10.5.3not-accessiblemandatory
x25StatEntry
OBJECT-TYPE
Entries of the x25StatTable.
1.3.6.1.2.1.10.5.3.1not-accessiblemandatory
x25StatIndex
OBJECT-TYPE
The ifIndex value for the X.25 interface.
1.3.6.1.2.1.10.5.3.1.1IfIndexTyperead-onlymandatory
x25StatInCalls
OBJECT-TYPE
The number of incoming calls received.
1.3.6.1.2.1.10.5.3.1.2Counterread-onlymandatory
x25StatInCallRefusals
OBJECT-TYPE
The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select.
1.3.6.1.2.1.10.5.3.1.3Counterread-onlymandatory
x25StatInProviderInitiatedClears
OBJECT-TYPE
The number of clear requests with a cause code other than DTE initiated.
1.3.6.1.2.1.10.5.3.1.4Counterread-onlymandatory
x25StatInRemotelyInitiatedResets
OBJECT-TYPE
The number of reset requests received with cause code DTE initiated.
1.3.6.1.2.1.10.5.3.1.5Counterread-onlymandatory
x25StatInProviderInitiatedResets
OBJECT-TYPE
The number of reset requests received with cause code other than DTE initiated.
1.3.6.1.2.1.10.5.3.1.6Counterread-onlymandatory
x25StatInRestarts
OBJECT-TYPE
The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE.
1.3.6.1.2.1.10.5.3.1.7Counterread-onlymandatory
x25StatInDataPackets
OBJECT-TYPE
The number of data packets received.
1.3.6.1.2.1.10.5.3.1.8Counterread-onlymandatory
x25StatInAccusedOfProtocolErrors
OBJECT-TYPE
The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets.
1.3.6.1.2.1.10.5.3.1.9Counterread-onlymandatory
x25StatInInterrupts
OBJECT-TYPE
The number of interrupt packets received by the PLE or over the PVC/VC.
1.3.6.1.2.1.10.5.3.1.10Counterread-onlymandatory
x25StatOutCallAttempts
OBJECT-TYPE
The number of calls attempted.
1.3.6.1.2.1.10.5.3.1.11Counterread-onlymandatory
x25StatOutCallFailures
OBJECT-TYPE
The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select.
1.3.6.1.2.1.10.5.3.1.12Counterread-onlymandatory
x25StatOutInterrupts
OBJECT-TYPE
The number of interrupt packets send by the PLE or over the PVC/VC.
1.3.6.1.2.1.10.5.3.1.13Counterread-onlymandatory
x25StatOutDataPackets
OBJECT-TYPE
The number of data packets sent by this PLE.
1.3.6.1.2.1.10.5.3.1.14Counterread-onlymandatory
x25StatOutgoingCircuits
OBJECT-TYPE
The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
1.3.6.1.2.1.10.5.3.1.15Gaugeread-onlymandatory
x25StatIncomingCircuits
OBJECT-TYPE
The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs.
1.3.6.1.2.1.10.5.3.1.16Gaugeread-onlymandatory
x25StatTwowayCircuits
OBJECT-TYPE
The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
1.3.6.1.2.1.10.5.3.1.17Gaugeread-onlymandatory
x25StatRestartTimeouts
OBJECT-TYPE
The number of times the T20 restart timer expired.
1.3.6.1.2.1.10.5.3.1.18Counterread-onlymandatory
x25StatCallTimeouts
OBJECT-TYPE
The number of times the T21 call timer expired.
1.3.6.1.2.1.10.5.3.1.19Counterread-onlymandatory
x25StatResetTimeouts
OBJECT-TYPE
The number of times the T22 reset timer expired.
1.3.6.1.2.1.10.5.3.1.20Counterread-onlymandatory
x25StatClearTimeouts
OBJECT-TYPE
The number of times the T23 clear timer expired.
1.3.6.1.2.1.10.5.3.1.21Counterread-onlymandatory
x25StatDataRxmtTimeouts
OBJECT-TYPE
The number of times the T25 data timer expired.
1.3.6.1.2.1.10.5.3.1.22Counterread-onlymandatory
x25StatInterruptTimeouts
OBJECT-TYPE
The number of times the T26 interrupt timer expired.
1.3.6.1.2.1.10.5.3.1.23Counterread-onlymandatory
x25StatRetryCountExceededs
OBJECT-TYPE
The number of times a retry counter was exhausted.
1.3.6.1.2.1.10.5.3.1.24Counterread-onlymandatory
x25StatClearCountExceededs
OBJECT-TYPE
The number of times the R23 clear count was exceeded.
1.3.6.1.2.1.10.5.3.1.25Counterread-onlymandatory
x25ChannelTable
OBJECT-TYPE
These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE.
1.3.6.1.2.1.10.5.4not-accessiblemandatory
x25ChannelEntry
OBJECT-TYPE
Entries of x25ChannelTable.
1.3.6.1.2.1.10.5.4.1not-accessiblemandatory
x25ChannelIndex
OBJECT-TYPE
The ifIndex value for the X.25 Interface.
1.3.6.1.2.1.10.5.4.1.1IfIndexTyperead-onlymandatory
x25ChannelLIC
OBJECT-TYPE
Lowest Incoming channel.
1.3.6.1.2.1.10.5.4.1.2INTEGER (0..4095)read-writemandatory
x25ChannelHIC
OBJECT-TYPE
Highest Incoming channel. A value of zero indicates no channels in this range.
1.3.6.1.2.1.10.5.4.1.3INTEGER (0..4095)read-writemandatory
x25ChannelLTC
OBJECT-TYPE
Lowest Two-way channel.
1.3.6.1.2.1.10.5.4.1.4INTEGER (0..4095)read-writemandatory
x25ChannelHTC
OBJECT-TYPE
Highest Two-way channel. A value of zero indicates no channels in this range.
1.3.6.1.2.1.10.5.4.1.5INTEGER (0..4095)read-writemandatory
x25ChannelLOC
OBJECT-TYPE
Lowest outgoing channel.
1.3.6.1.2.1.10.5.4.1.6INTEGER (0..4095)read-writemandatory
x25ChannelHOC
OBJECT-TYPE
Highest outgoing channel. A value of zero indicates no channels in this range.
1.3.6.1.2.1.10.5.4.1.7INTEGER (0..4095)read-writemandatory
x25CircuitTable
OBJECT-TYPE
These objects contain general information about a specific circuit of an X.25 PLE.
1.3.6.1.2.1.10.5.5not-accessiblemandatory
x25CircuitEntry
OBJECT-TYPE
Entries of x25CircuitTable.
1.3.6.1.2.1.10.5.5.1not-accessiblemandatory
x25CircuitIndex
OBJECT-TYPE
The ifIndex value for the X.25 Interface.
1.3.6.1.2.1.10.5.5.1.1IfIndexTyperead-onlymandatory
x25CircuitChannel
OBJECT-TYPE
The channel number for this circuit.
1.3.6.1.2.1.10.5.5.1.2INTEGER (0..4095)read-onlymandatory
x25CircuitStatus
OBJECT-TYPE
This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start clearing the circuit. An instance with the value PVC can only be set to startPvcResetting or invalid and that action resets the PVC or deletes the circuit respectively. The values startClear or startPvcResetting will never be returned by an agent. An attempt to set the status of an existing instance to a value other than one of these values will result in an error. A non-existing instance can be set to PVC to create a PVC if the implementation supports dynamic creation of PVCs. Some implementations may only allow creation and deletion of PVCs if the interface is down. Since the instance identifier will supply the PLE index and the channel number, setting this object alone supplies sufficient information to create the instance. All the DEFVAL clauses for the other objects of this table are appropriate for creating a PVC; PLEs creating entries for placed or accepted calls will use values appropriate for the call rather than the value of the DEFVAL clause. Two managers trying to create the same PVC can determine from the return code which manager succeeded and which failed (the failing manager fails because it can not set a value of PVC for an existing object). An entry in the closed or invalid state may be deleted or reused at the agent's convence. If the entry is kept in the closed state, the values of the parameters associated with the entry must be correct. Closed implies the values in the circuit table are correct. The value of invalid indicates the other values in the table are invalid. Many agents may never return a value of invalid because they dynamically allocate and free unused table entries. An agent for a statically configured systems can return invalid to indicate the entry has not yet been used so the counters contain no information.
1.3.6.1.2.1.10.5.5.1.3INTEGER {invalid(1), closed(2), calling(3), open(4), clearing(5), pvc(6), pvcResetting(7), startClear(8), startPvcResetting(9), other(10)}read-writemandatory
x25CircuitEstablishTime
OBJECT-TYPE
The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data.
1.3.6.1.2.1.10.5.5.1.4TimeTicksread-onlymandatory
x25CircuitDirection
OBJECT-TYPE
The direction of the call that established this circuit.
1.3.6.1.2.1.10.5.5.1.5INTEGER {incoming(1), outgoing(2), pvc(3)}read-writemandatory
x25CircuitInOctets
OBJECT-TYPE
The number of octets of user data delivered to upper layer.
1.3.6.1.2.1.10.5.5.1.6Counterread-onlymandatory
x25CircuitInPdus
OBJECT-TYPE
The number of PDUs received for this circuit.
1.3.6.1.2.1.10.5.5.1.7Counterread-onlymandatory
x25CircuitInRemotelyInitiatedResets
OBJECT-TYPE
The number of Resets received for this circuit with cause code of DTE initiated.
1.3.6.1.2.1.10.5.5.1.8Counterread-onlymandatory
x25CircuitInProviderInitiatedResets
OBJECT-TYPE
The number of Resets received for this circuit with cause code other than DTE initiated.
1.3.6.1.2.1.10.5.5.1.9Counterread-onlymandatory
x25CircuitInInterrupts
OBJECT-TYPE
The number of interrupt packets received for this circuit.
1.3.6.1.2.1.10.5.5.1.10Counterread-onlymandatory
x25CircuitOutOctets
OBJECT-TYPE
The number of octets of user data sent for this circuit.
1.3.6.1.2.1.10.5.5.1.11Counterread-onlymandatory
x25CircuitOutPdus
OBJECT-TYPE
The number of PDUs sent for this circuit.
1.3.6.1.2.1.10.5.5.1.12Counterread-onlymandatory
x25CircuitOutInterrupts
OBJECT-TYPE
The number of interrupt packets sent on this circuit.
1.3.6.1.2.1.10.5.5.1.13Counterread-onlymandatory
x25CircuitDataRetransmissionTimeouts
OBJECT-TYPE
The number of times the T25 data retransmission timer expired for this circuit.
1.3.6.1.2.1.10.5.5.1.14Counterread-onlymandatory
x25CircuitResetTimeouts
OBJECT-TYPE
The number of times the T22 reset timer expired for this circuit.
1.3.6.1.2.1.10.5.5.1.15Counterread-onlymandatory
x25CircuitInterruptTimeouts
OBJECT-TYPE
The number of times the T26 Interrupt timer expired for this circuit.
1.3.6.1.2.1.10.5.5.1.16Counterread-onlymandatory
x25CircuitCallParamId
OBJECT-TYPE
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters.
1.3.6.1.2.1.10.5.5.1.17OBJECT IDENTIFIERread-writemandatory
x25CircuitCalledDteAddress
OBJECT-TYPE
For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs.
1.3.6.1.2.1.10.5.5.1.18X121Addressread-writemandatory
x25CircuitCallingDteAddress
OBJECT-TYPE
For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs.
1.3.6.1.2.1.10.5.5.1.19X121Addressread-writemandatory
x25CircuitOriginallyCalledAddress
OBJECT-TYPE
For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address from the call request packet. This will be zero length for PVCs.
1.3.6.1.2.1.10.5.5.1.20X121Addressread-writemandatory
x25CircuitDescr
OBJECT-TYPE
A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using the circuit. Alternative the agent may return the name of the configuration entry that caused a bridge to establish the circuit. A zero length value indicates the agent doesn't have any additional information.
1.3.6.1.2.1.10.5.5.1.21DisplayString (SIZE(0..255))read-writemandatory
x25ClearedCircuitEntriesRequested
OBJECT-TYPE
The requested number of entries for the agent to keep in the x25ClearedCircuit table.
1.3.6.1.2.1.10.5.6PositiveIntegerread-writemandatory
x25ClearedCircuitEntriesGranted
OBJECT-TYPE
The actual number of entries the agent will keep in the x25ClearedCircuit Table.
1.3.6.1.2.1.10.5.7PositiveIntegerread-onlymandatory
x25ClearedCircuitTable
OBJECT-TYPE
A table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet contains a clearing cause other than DTE Originated or a Diagnostic code field other than Higher Layer Initiated disconnection-normal. An agent may optionally make entries for normal closes (to record closing facilities or other information). Agents will delete the oldest entry in the table when adding a new entry would exceed agent resources. Agents are required to keep the last entry put in the table and may keep more entries. The object x25OperClearEntriesGranted returns the maximum number of entries kept in the table.
1.3.6.1.2.1.10.5.8not-accessiblemandatory
x25ClearedCircuitEntry
OBJECT-TYPE
Information about a cleared circuit.
1.3.6.1.2.1.10.5.8.1not-accessiblemandatory
x25ClearedCircuitIndex
OBJECT-TYPE
An index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each new entry added to the table. Upon reaching one, the index will reset to 2147483647. Because the index starts at 2147483647 and decreases, a manager may do a getnext on entry zero and obtain the most recent entry. When the index has the value of 1, the next entry will delete all entries in the table and that entry will be numbered 2147483647.
1.3.6.1.2.1.10.5.8.1.1PositiveIntegerread-onlymandatory
x25ClearedCircuitPleIndex
OBJECT-TYPE
The value of ifIndex for the PLE which cleared the circuit that created the entry.
1.3.6.1.2.1.10.5.8.1.2IfIndexTyperead-onlymandatory
x25ClearedCircuitTimeEstablished
OBJECT-TYPE
The value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit.
1.3.6.1.2.1.10.5.8.1.3TimeTicksread-onlymandatory
x25ClearedCircuitTimeCleared
OBJECT-TYPE
The value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely initiated clears, this will be the time when the clear indication was received.
1.3.6.1.2.1.10.5.8.1.4TimeTicksread-onlymandatory
x25ClearedCircuitChannel
OBJECT-TYPE
The channel number for the circuit that was cleared.
1.3.6.1.2.1.10.5.8.1.5INTEGER (0..4095)read-onlymandatory
x25ClearedCircuitClearingCause
OBJECT-TYPE
The Clearing Cause from the clear request or clear indication packet that cleared the circuit.
1.3.6.1.2.1.10.5.8.1.6INTEGER (0..255)read-onlymandatory
x25ClearedCircuitDiagnosticCode
OBJECT-TYPE
The Diagnostic Code from the clear request or clear indication packet that cleared the circuit.
1.3.6.1.2.1.10.5.8.1.7INTEGER (0..255)read-onlymandatory
x25ClearedCircuitInPdus
OBJECT-TYPE
The number of PDUs received on the circuit.
1.3.6.1.2.1.10.5.8.1.8Counterread-onlymandatory
x25ClearedCircuitOutPdus
OBJECT-TYPE
The number of PDUs transmitted on the circuit.
1.3.6.1.2.1.10.5.8.1.9Counterread-onlymandatory
x25ClearedCircuitCalledAddress
OBJECT-TYPE
The called address from the cleared circuit.
1.3.6.1.2.1.10.5.8.1.10X121Addressread-onlymandatory
x25ClearedCircuitCallingAddress
OBJECT-TYPE
The calling address from the cleared circuit.
1.3.6.1.2.1.10.5.8.1.11X121Addressread-onlymandatory
x25ClearedCircuitClearFacilities
OBJECT-TYPE
The facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present.
1.3.6.1.2.1.10.5.8.1.12OCTET STRING (SIZE(0..109))read-onlymandatory
x25CallParmTable
OBJECT-TYPE
These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any circuit. Other tables reference entries in this table. Entries in this table can be used for default PLE parameters, for parameters to use to place/answer a call, for the parameters currently in use for a circuit, or parameters that were used by a circuit. The number of references to a given set of parameters can be found in the x25CallParmRefCount object sharing the same instance identifier with the parameters. The value of this reference count also affects the access of the objects in this table. An object in this table with the same instance identifier as the instance identifier of an x25CallParmRefCount must be consider associated with that reference count. An object with an associated reference count of zero can be written (if its ACCESS clause allows it). An object with an associated reference count greater than zero can not be written (regardless of the ACCESS clause). This ensures that a set of call parameters being referenced from another table can not be modified or changed in a ways inappropriate for continued use by that table.
1.3.6.1.2.1.10.5.9not-accessiblemandatory
x25CallParmEntry
OBJECT-TYPE
Entries of x25CallParmTable.
1.3.6.1.2.1.10.5.9.1not-accessiblemandatory
x25CallParmIndex
OBJECT-TYPE
A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this table. Because of this, changes to parameters must be accomplished by creating a new entry in this table and then changing the referencing table to identify the new entry. Note that an agent will only use the values in this table when another table is changed to reference those values. The number of other tables that reference an index object in this table can be found in x25CallParmRefCount. The value of the reference count will affect the writability of the objects as explained above. Entries in this table which have a reference count of zero maybe deleted at the convence of the agent. Care should be taken by the agent to give the NMS sufficient time to create a reference to newly created entries. Should a Management Station not find a free index with which to create a new entry, it may feel free to delete entries with a reference count of zero. However in doing so the Management Station much realize it may impact other Management Stations.
1.3.6.1.2.1.10.5.9.1.1PositiveIntegerread-onlymandatory
x25CallParmStatus
OBJECT-TYPE
The status of this call parameter entry. See RFC 1271 for details of usage.
1.3.6.1.2.1.10.5.9.1.2EntryStatusread-writemandatory
x25CallParmRefCount
OBJECT-TYPE
The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such objects are the x25AdmnDefCallParamId, x25OperDataLinkId, or x25AdmnDefCallParamId objects defined above.
1.3.6.1.2.1.10.5.9.1.3PositiveIntegerread-onlymandatory
x25CallParmInPacketSize
OBJECT-TYPE
The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128.
1.3.6.1.2.1.10.5.9.1.4INTEGER (0..4096)read-writemandatory
x25CallParmOutPacketSize
OBJECT-TYPE
The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128.
1.3.6.1.2.1.10.5.9.1.5INTEGER (0..4096)read-writemandatory
x25CallParmInWindowSize
OBJECT-TYPE
The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
1.3.6.1.2.1.10.5.9.1.6INTEGER (0..127)read-writemandatory
x25CallParmOutWindowSize
OBJECT-TYPE
The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
1.3.6.1.2.1.10.5.9.1.7INTEGER (0..127)read-writemandatory
x25CallParmAcceptReverseCharging
OBJECT-TYPE
An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value of default for a PLE default means refuse.
1.3.6.1.2.1.10.5.9.1.8INTEGER {default(1), accept(2), refuse(3), neverAccept(4)}read-writemandatory
x25CallParmProposeReverseCharging
OBJECT-TYPE
An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local.
1.3.6.1.2.1.10.5.9.1.9INTEGER {default(1), reverse(2), local(3)}read-writemandatory
x25CallParmFastSelect
OBJECT-TYPE
Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast select or restricted fast response.
1.3.6.1.2.1.10.5.9.1.10INTEGER {default(1), notSpecified(2), fastSelect(3), restrictedFastResponse(4), noFastSelect(5), noRestrictedFastResponse(6)}read-writemandatory
x25CallParmInThruPutClasSize
OBJECT-TYPE
The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class.
1.3.6.1.2.1.10.5.9.1.11INTEGER {tcReserved1(1), tcReserved2(2), tc75(3), tc150(4), tc300(5), tc600(6), tc1200(7), tc2400(8), tc4800(9), tc9600(10), tc19200(11), tc48000(12), tc64000(13), tcReserved14(14), tcReserved15(15), tcReserved0(16), tcNone(17), tcDefault(18)}read-writemandatory
x25CallParmOutThruPutClasSize
OBJECT-TYPE
The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class.
1.3.6.1.2.1.10.5.9.1.12INTEGER {tcReserved1(1), tcReserved2(2), tc75(3), tc150(4), tc300(5), tc600(6), tc1200(7), tc2400(8), tc4800(9), tc9600(10), tc19200(11), tc48000(12), tc64000(13), tcReserved14(14), tcReserved15(15), tcReserved0(16), tcNone(17), tcDefault(18)}read-writemandatory
x25CallParmCug
OBJECT-TYPE
The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE default, (the PLE default parameter may not reference an entry of DEF.)
1.3.6.1.2.1.10.5.9.1.13DisplayString (SIZE(0..4))read-writemandatory
x25CallParmCugoa
OBJECT-TYPE
The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters may not reference an entry of DEF). A zero length string indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.14DisplayString (SIZE(0..4))read-writemandatory
x25CallParmBcug
OBJECT-TYPE
The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an entry of DEF). A zero length string indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.15DisplayString (SIZE(0..3))read-writemandatory
x25CallParmNui
OBJECT-TYPE
The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default parameters entry.
1.3.6.1.2.1.10.5.9.1.16OCTET STRING (SIZE(0..108))read-writemandatory
x25CallParmChargingInfo
OBJECT-TYPE
The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility.
1.3.6.1.2.1.10.5.9.1.17INTEGER {default(1), noFacility(2), noChargingInfo(3), chargingInfo(4)}read-writemandatory
x25CallParmRpoa
OBJECT-TYPE
The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may not contain DEF). A zero length string indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.18DisplayString (SIZE(0..108))read-writemandatory
x25CallParmTrnstDly
OBJECT-TYPE
The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be used to indicate the value in use by a circuit.
1.3.6.1.2.1.10.5.9.1.19INTEGER (0..65537)read-writemandatory
x25CallParmCallingExt
OBJECT-TYPE
The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.20DisplayString (SIZE(0..40))read-writemandatory
x25CallParmCalledExt
OBJECT-TYPE
The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.21DisplayString (SIZE(0..40))read-writemandatory
x25CallParmInMinThuPutCls
OBJECT-TYPE
The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.22INTEGER (0..17)read-writemandatory
x25CallParmOutMinThuPutCls
OBJECT-TYPE
The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.23INTEGER (0..17)read-writemandatory
x25CallParmEndTrnsDly
OBJECT-TYPE
The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested.
1.3.6.1.2.1.10.5.9.1.24OCTET STRING (SIZE(0..6))read-writemandatory
x25CallParmPriority
OBJECT-TYPE
The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length.
1.3.6.1.2.1.10.5.9.1.25OCTET STRING (SIZE(0..6))read-writemandatory
x25CallParmProtection
OBJECT-TYPE
A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contained in this string. An string containing the 3 characters DEF for a circuit means use the PLE default (the entry for the PLE default parameters may not use the value DEF). A zero length string mean no facility requested.
1.3.6.1.2.1.10.5.9.1.26DisplayString (SIZE(0..108))read-writemandatory
x25CallParmExptData
OBJECT-TYPE
The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default.
1.3.6.1.2.1.10.5.9.1.27INTEGER {default(1), noExpeditedData(2), expeditedData(3)}read-writemandatory
x25CallParmUserData
OBJECT-TYPE
The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent.
1.3.6.1.2.1.10.5.9.1.28OCTET STRING (SIZE(0..128))read-writemandatory
x25CallParmCallingNetworkFacilities
OBJECT-TYPE
The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities.
1.3.6.1.2.1.10.5.9.1.29OCTET STRING (SIZE(0..108))read-writemandatory
x25CallParmCalledNetworkFacilities
OBJECT-TYPE
The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities.
1.3.6.1.2.1.10.5.9.1.30OCTET STRING (SIZE(0..108))read-writemandatory
x25ProtocolVersion
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10
x25protocolCcittV1976
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10.1
x25protocolCcittV1980
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10.2
x25protocolCcittV1984
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10.3
x25protocolCcittV1988
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10.4
x25protocolIso8208V1987
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10.5
x25protocolIso8208V1989
OBJECT-IDENTITY
1.3.6.1.2.1.10.5.10.6

Notifications

NameOIDStatus
x25Restart
NOTIFICATION-TYPE
This trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should send a linkUp trap. Sending this trap means the agent does not send a linkDown and linkUp trap.
1.3.6.1.2.1.10.5.0.1
x25Reset
NOTIFICATION-TYPE
If the PLE sends or receives a reset, the agent should send an x25Reset trap.
1.3.6.1.2.1.10.5.0.2