MIBs Depot

RFC1285-MIB

Registered at
1.3.6.1.2.1.10.15.1
1.3.6.1.2.1.10.15.2
1.3.6.1.2.1.10.15.3
1.3.6.1.2.1.10.15.4
1.3.6.1.2.1.10.15.5
1.3.6.1.2.1.10.15.6
Namespace
standard
Source file
RFC1285-MIB
Digest
sha256:124ca348a511b273b137cef607cf6acd9bcbd62cca2515de6ccfe735a446da06

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso, transmission
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

RFC1285-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
FddiMACLongAddressType
type
FddiResourceId
type
FddiSMTStationIdType
type
FddiTime
type

Objects

NameOIDSyntaxAccessStatus
fddi
OBJECT-IDENTITY
1.3.6.1.2.1.10.15
snmpFddiSMT
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.1
snmpFddiSMTNumber
OBJECT-TYPE
The number of SMT implementations (regardless of their current state) on this network management application entity. The value for this variable must remain constant at least from one re- initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.1.1INTEGER (0..65535)read-onlymandatory
snmpFddiSMTTable
OBJECT-TYPE
A list of SMT entries. The number of entries is given by the value of snmpFddiSMTNumber.
1.3.6.1.2.1.10.15.1.2not-accessiblemandatory
snmpFddiSMTEntry
OBJECT-TYPE
An SMT entry containing information common to a given SMT.
1.3.6.1.2.1.10.15.1.2.1not-accessiblemandatory
snmpFddiSMTIndex
OBJECT-TYPE
A unique value for each SMT. Its value ranges between 1 and the value of snmpFddiSMTNumber. The value for each SMT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.1.2.1.1INTEGER (1..65535)read-onlymandatory
snmpFddiSMTStationId
OBJECT-TYPE
Uniquely identifies an FDDI station.
1.3.6.1.2.1.10.15.1.2.1.2FddiSMTStationIdTyperead-onlymandatory
snmpFddiSMTOpVersionId
OBJECT-TYPE
The version that this station is using for its operation (refer to ANSI 7.1.2.2).
1.3.6.1.2.1.10.15.1.2.1.3INTEGER (1..65535)read-writemandatory
snmpFddiSMTHiVersionId
OBJECT-TYPE
The highest version of SMT that this station supports (refer to ANSI 7.1.2.2).
1.3.6.1.2.1.10.15.1.2.1.4INTEGER (1..65535)read-onlymandatory
snmpFddiSMTLoVersionId
OBJECT-TYPE
The lowest version of SMT that this station supports (refer to ANSI 7.1.2.2).
1.3.6.1.2.1.10.15.1.2.1.5INTEGER (1..65535)read-onlymandatory
snmpFddiSMTMACCt
OBJECT-TYPE
The number of MACs in the station or concentrator.
1.3.6.1.2.1.10.15.1.2.1.6INTEGER (0..255)read-onlymandatory
snmpFddiSMTNonMasterCt
OBJECT-TYPE
The number of Non Master PORTs (A, B, or S PORTs) in the station or concentrator.
1.3.6.1.2.1.10.15.1.2.1.7INTEGER (0..2)read-onlymandatory
snmpFddiSMTMasterCt
OBJECT-TYPE
The number of Master PORTs in a node. If the node is not a concentrator, the value is zero.
1.3.6.1.2.1.10.15.1.2.1.8INTEGER (0..255)read-onlymandatory
snmpFddiSMTPathsAvailable
OBJECT-TYPE
A value that indicates the PATH types available in the station. The value is a sum. This value initially takes the value zero, then for each type of PATH that this node has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 For example, a station having Primary and Local PATHs available would have a value of 5 (2**0 + 2**2).
1.3.6.1.2.1.10.15.1.2.1.9INTEGER (0..7)read-onlymandatory
snmpFddiSMTConfigCapabilities
OBJECT-TYPE
A value that indicates capabilities that are present in the node. If 'holdAvailable' is present, this indicates support of the optional Hold Function (refer to ANSI SMT 9.4.3.2). If 'CF-Wrap-AB' is present, this indicates that the WRAP_AB state is forced. The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power holdAvailable 0 CF-Wrap-AB 1
1.3.6.1.2.1.10.15.1.2.1.10INTEGER (0..3)read-onlymandatory
snmpFddiSMTConfigPolicy
OBJECT-TYPE
A value that indicates the configuration policies currently enforced in the node (refer to ANSI SMT 9.4.3.2). The 'configurationHold' policy refers to the Hold flag, and should not be present only if the Hold function is supported. The 'CF-Wrap- AB' policy refers to the CF_Wrap_AB flag. The value is a sum. This value initially takes the value zero, then for each of the configuration policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power configurationHold 0 CF-Wrap-AB 1
1.3.6.1.2.1.10.15.1.2.1.11INTEGER (0..3)read-writemandatory
snmpFddiSMTConnectionPolicy
OBJECT-TYPE
A value that indicates the connection policies enforced at the station. A station sets the corresponding policy for each of the connection types that it rejects. The letter designations, X and Y, in the 'rejectX-Y' names have the following significance: X represents the PC-Type of the local PORT and Y represents a PC-Neighbor in the evaluation of Connection-Policy (PC-Type, PC- Neighbor) that is done to determine the setting of T-Val(3) in the PC-Signaling sequence (refer to ANSI Section 9.6.3). The value is a sum. This value initially takes the value zero, then for each of the connection policies currently enforced on the node, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power rejectA-A 0 rejectA-B 1 rejectA-S 2 rejectA-M 3 rejectB-A 4 rejectB-B 5 rejectB-S 6 rejectB-M 7 rejectS-A 8 rejectS-B 9 rejectS-S 10 rejectS-M 11 rejectM-A 12 rejectM-B 13 rejectM-S 14 rejectM-M 15 Implementors should note that the polarity of these bits is different in different places in an SMT system. Implementors should take appropriate care.
1.3.6.1.2.1.10.15.1.2.1.12INTEGER (0..65535)read-writemandatory
snmpFddiSMTTNotify
OBJECT-TYPE
The timer used in the Neighbor Notification protocol, reported in seconds and ranging from 2 to 30 seconds (refer to ANSI SMT 8.3.1).
1.3.6.1.2.1.10.15.1.2.1.13INTEGER (2..30)read-writemandatory
snmpFddiSMTStatusReporting
OBJECT-TYPE
Indicates whether the node implements the Status Reporting Protocol. This object is included for compatibility with products that were designed prior to the adoption of this standard.
1.3.6.1.2.1.10.15.1.2.1.14INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiSMTECMState
OBJECT-TYPE
Indicates the current state of the ECM state machine (refer to ANSI SMT 9.5.2).
1.3.6.1.2.1.10.15.1.2.1.15INTEGER {ec0(1), ec1(2), ec2(3), ec3(4), ec4(5), ec5(6), ec6(7), ec7(8)}read-onlymandatory
snmpFddiSMTCFState
OBJECT-TYPE
The attachment configuration for the station or concentrator (refer to ANSI SMT 9.7.4.3).
1.3.6.1.2.1.10.15.1.2.1.16INTEGER {cf0(1), cf1(2), cf2(3), cf3(4), cf4(5), cf5(6)}read-onlymandatory
snmpFddiSMTHoldState
OBJECT-TYPE
This value indicates the current state of the Hold function. The values are determined as follows: 'holding-prm' is set if the primary ring is operational and the Recovery Enable Flag is clear (NOT NO_Flag(primary) AND NOT RE_Flag). is set if the secondary ring is operational and the Recovery Enable Flag is clear (NOT NO_Flag(secondary) AND NOT RE_Flag). Ref 9.4.3. and 10.3.1. the primary or secondary, i.e., the Recovery Enable, RE_Flag, is set.
1.3.6.1.2.1.10.15.1.2.1.17INTEGER {not-implemented(1), not-holding(2), holding-prm(3), holding-sec(4)}read-onlymandatory
snmpFddiSMTRemoteDisconnectFlag
OBJECT-TYPE
A flag indicating that the station was remotely disconnected from the network. A station requires a Connect Action (SM_CM_CONNECT.request (Connect)) to rejoin and clear the flag (refer to ANSI 6.4.5.2).
1.3.6.1.2.1.10.15.1.2.1.18INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiSMTStationAction
OBJECT-TYPE
This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: Other: Results in a badValue error. Connect: Generates an SM_CM_Connect.request(connect) signal to CMT indicating that the ECM State machine is to begin a connection sequence. The fddiSMTRemoteDisconnectFlag is cleared on the setting of this variable to 1. See ANSI Ref 9.3.1.1. Disconnect: Generates an SM_CM_Connect.request(disconnect) signal to ECM and sets the fddiSMTRemoteDisconnectFlag. See ANSI Ref 9.3.1.1. Path-Test: Initiates a station path test. The Path_Test variable (See ANSI Ref. 9.4.1) is set to Testing. The results of this action are not specified in this standard. Self-Test: Initiates a station self test. The results of this action are not specified in this standard. Attempts to set this object to all other values results in a badValue error. Agents may elect to return a badValue error on attempts to set this variable to path-Test(4) or self-Test(5).
1.3.6.1.2.1.10.15.1.2.1.19INTEGER {other(1), connect(2), disconnect(3), path-Test(4), self-Test(5)}read-writemandatory
snmpFddiMAC
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.2
snmpFddiMACNumber
OBJECT-TYPE
The total number of MAC implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.2.1INTEGER (0..65535)read-onlymandatory
snmpFddiMACTable
OBJECT-TYPE
A list of MAC entries. The number of entries is given by the value of snmpFddiMACNumber.
1.3.6.1.2.1.10.15.2.2not-accessiblemandatory
snmpFddiMACEntry
OBJECT-TYPE
A MAC entry containing information common to a given MAC.
1.3.6.1.2.1.10.15.2.2.1not-accessiblemandatory
snmpFddiMACSMTIndex
OBJECT-TYPE
The value of the SMT index associated with this MAC.
1.3.6.1.2.1.10.15.2.2.1.1INTEGER (1..65535)read-onlymandatory
snmpFddiMACIndex
OBJECT-TYPE
A unique value for each MAC on the managed entity. The MAC identified by a particular value of this index is that identified by the same value of an ifIndex object instance. That is, if a MAC is associated with the interface whose value of ifIndex in the Internet-Standard MIB is equal to 5, then the value of snmpFddiMACIndex shall also equal 5. The value for each MAC must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.2.2.1.2INTEGER (1..65535)read-onlymandatory
snmpFddiMACFrameStatusCapabilities
OBJECT-TYPE
A value that indicates the MAC's bridge and end- station capabilities for operating in a bridged FDDI network. The value is a sum. This value initially takes the value zero, then for each capability present, 2 raised to a power is added to the sum. The powers are according to the following table: Capability Power FSC-Type0 0 -- MAC repeats A/C indicators as received on -- copying with the intent to forward. FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding. FSC-Type2 2 -- MAC resets C and sets A on C set and -- A reset if the frame is not copied and the -- frame was addressed to this MAC FSC-Type0-programmable 8 -- Type0 capability is programmable FSC-Type1-programmable 9 -- Type1 capability is programmable FSC-Type2-programmable 10 -- Type2 capability is programmable
1.3.6.1.2.1.10.15.2.2.1.3INTEGER (0..1799)read-onlymandatory
snmpFddiMACTMaxGreatestLowerBound
OBJECT-TYPE
The greatest lower bound of T_Max supported for this MAC.
1.3.6.1.2.1.10.15.2.2.1.4FddiTimeread-writemandatory
snmpFddiMACTVXGreatestLowerBound
OBJECT-TYPE
The greatest lower bound of TVX supported for this MAC.
1.3.6.1.2.1.10.15.2.2.1.5FddiTimeread-onlymandatory
snmpFddiMACPathsAvailable
OBJECT-TYPE
A value that indicates the PATH types available for this MAC. The value is a sum. This value initially takes the value zero, then for each type of PATH that this MAC has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2
1.3.6.1.2.1.10.15.2.2.1.6INTEGER (0..7)read-onlymandatory
snmpFddiMACCurrentPath
OBJECT-TYPE
Indicates the association of the MAC with a station PATH.
1.3.6.1.2.1.10.15.2.2.1.7INTEGER {unknown(1), primary(2), secondary(4), local(8), isolated(16)}read-onlymandatory
snmpFddiMACUpstreamNbr
OBJECT-TYPE
The MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown.
1.3.6.1.2.1.10.15.2.2.1.8FddiMACLongAddressTyperead-onlymandatory
snmpFddiMACOldUpstreamNbr
OBJECT-TYPE
The previous value of the MAC's upstream neighbor's long individual MAC address. It may be determined by the Neighbor Information Frame protocol (refer to ANSI SMT 7.2.1). The value shall be reported as '00 00 00 00 00 00' if it is unknown.
1.3.6.1.2.1.10.15.2.2.1.9FddiMACLongAddressTyperead-onlymandatory
snmpFddiMACDupAddrTest
OBJECT-TYPE
The Duplicate Address Test flag, Dup_Addr_Test (refer to ANSI 8.3.1).
1.3.6.1.2.1.10.15.2.2.1.10INTEGER {none(1), pass(2), fail(3)}read-onlymandatory
snmpFddiMACPathsRequested
OBJECT-TYPE
A value that indicates PATH(s) desired for this MAC. The value is a sum which represents the individual PATHs that are desired. This value initially takes the value zero, then for each type of PATH that this node is, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 Isolated 3 The precedence order is primary, secondary, local, and then isolated if multiple PATHs are desired are set.
1.3.6.1.2.1.10.15.2.2.1.11INTEGERread-writemandatory
snmpFddiMACDownstreamPORTType
OBJECT-TYPE
Indicates the PC-Type of the first port that is downstream of this MAC (the exit port).
1.3.6.1.2.1.10.15.2.2.1.12INTEGER {a(1), b(2), s(3), m(4), unknown(5)}read-onlymandatory
snmpFddiMACSMTAddress
OBJECT-TYPE
The 48 bit individual address of the MAC used for SMT frames.
1.3.6.1.2.1.10.15.2.2.1.13FddiMACLongAddressTyperead-onlymandatory
snmpFddiMACTReq
OBJECT-TYPE
The value of T-Req (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2).
1.3.6.1.2.1.10.15.2.2.1.14FddiTimeread-writemandatory
snmpFddiMACTNeg
OBJECT-TYPE
The value of T-Neg (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2).
1.3.6.1.2.1.10.15.2.2.1.15FddiTimeread-onlymandatory
snmpFddiMACTMax
OBJECT-TYPE
The value of T-Max (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2).
1.3.6.1.2.1.10.15.2.2.1.16FddiTimeread-onlymandatory
snmpFddiMACTvxValue
OBJECT-TYPE
The value of TvxValue (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2).
1.3.6.1.2.1.10.15.2.2.1.17FddiTimeread-onlymandatory
snmpFddiMACTMin
OBJECT-TYPE
The value of T-Min (refer to ANSI MAC 2.2.1 and ANSI MAC 7.3.5.2).
1.3.6.1.2.1.10.15.2.2.1.18FddiTimeread-onlymandatory
snmpFddiMACCurrentFrameStatus
OBJECT-TYPE
A value that indicates the MAC's operational frame status setting functionality. The value is a sum. This value initially takes the value zero, then for each functionality present, 2 raised to a power is added to the sum. The powers are according to the following table: Functionality Power FSC-Type0 0 -- MAC repeats A/C indicators as received FSC-Type1 1 -- MAC sets C but not A on copying for -- forwarding FSC-Type2 2 -- MAC resets C and sets A on C set and A -- reset if frame is not copied
1.3.6.1.2.1.10.15.2.2.1.19INTEGER (0..7)read-writemandatory
snmpFddiMACFrameCts
OBJECT-TYPE
Frame_Ct (refer to ANSI MAC 2.2.1).
1.3.6.1.2.1.10.15.2.2.1.20Counterread-onlymandatory
snmpFddiMACErrorCts
OBJECT-TYPE
Error_Ct (refer to ANSI MAC 2.2.1).
1.3.6.1.2.1.10.15.2.2.1.21Counterread-onlymandatory
snmpFddiMACLostCts
OBJECT-TYPE
Lost_Ct (refer to ANSI MAC 2.2.1).
1.3.6.1.2.1.10.15.2.2.1.22Counterread-onlymandatory
snmpFddiMACFrameErrorThreshold
OBJECT-TYPE
A threshold for determining when a MAC Condition report should be generated. The condition is true when the ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16. exceeds the threshold. It is used to determine when a station has an unacceptable frame error threshold. The sampling algorithm is implementation dependent. Any attempt to set this variable to a value of less than one shall result in a badValue error. Those who are familiar with the SNMP management framework will recognize that thresholds are not in keeping with the SNMP philosophy. However, this variable is supported by underlying SMT implementations already and maintaining this threshold should not pose an undue additional burden on SNMP agent implementors.
1.3.6.1.2.1.10.15.2.2.1.23INTEGER (1..65535)read-onlymandatory
snmpFddiMACFrameErrorRatio
OBJECT-TYPE
This attribute is the actual ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16.
1.3.6.1.2.1.10.15.2.2.1.24INTEGER (1..65535)read-onlymandatory
snmpFddiMACRMTState
OBJECT-TYPE
Indicates the current state of the Ring Management state machine (refer to ANSI Section 10).
1.3.6.1.2.1.10.15.2.2.1.25INTEGER {rm0(1), rm1(2), rm2(3), rm3(4), rm4(5), rm5(6), rm6(7), rm7(8)}read-onlymandatory
snmpFddiMACDaFlag
OBJECT-TYPE
The RMT flag Duplicate Address Flag, DA_Flag (refer to ANSI 10.3.1.2).
1.3.6.1.2.1.10.15.2.2.1.26INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiMACUnaDaFlag
OBJECT-TYPE
A flag set when the upstream neighbor reports a duplicate address condition. Reset when the condition clears.
1.3.6.1.2.1.10.15.2.2.1.27INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiMACFrameCondition
OBJECT-TYPE
Indicates the MAC Condition is active when set. Cleared when the condition clears and on power up.
1.3.6.1.2.1.10.15.2.2.1.28INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiMACChipSet
OBJECT-TYPE
This object identifies the hardware chip(s) which is (are) principally responsible for the implementation of the MAC function. A few OBJECT IDENTIFIERS are identified elsewhere in this memo. For those The assignment of additional OBJECT IDENTIFIERs to various types of hardware chip sets is managed by the IANA. For example, vendors whose chip sets are not defined in this memo may request a number from the Internet Assigned Numbers Authority (IANA) which indicates the assignment of a enterprise specific subtree which, among other things, may be used to allocate OBJECT IDENTIFIER assignments for that enterprise's chip sets. Similarly, in the absence of an appropriately assigned OBJECT IDENTIFIER in this memo or in an enterprise specific subtree of a chip vendor, a board or system vendor can request a number for a subtree from the IANA and make an appropriate assignment. It is desired that, whenever possible, the same OBJECT IDENTIFIER be used for all chips of a given type. Consequently, the assignment made in this memo for a chip, if any, should be used in preference to any other assignment and the assignment made by the chip manufacturer, if any, should be used in preference to assignments made by users of those chips. If the hardware chip set is unknown, the object identifier unknownChipSet OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownChipSet is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value.
1.3.6.1.2.1.10.15.2.2.1.29OBJECT IDENTIFIERread-onlymandatory
snmpFddiMACAction
OBJECT-TYPE
This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: Other: Results in a badValue error. enableLLCService: enables MAC service to higher layers. disableLLCService: disables MAC service to higher layers. connectMAC: connect this MAC in station. disconnectMAC: disconnect this MAC in station. Attempts to set this object to all other values results in a badValue error.
1.3.6.1.2.1.10.15.2.2.1.30INTEGER {other(1), enableLLCService(2), disableLLCService(3), connectMAC(4), disconnectMAC(5)}read-writemandatory
snmpFddiPATH
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.3
snmpFddiPORT
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.4
snmpFddiPORTNumber
OBJECT-TYPE
The total number of PORT implementations (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.4.1INTEGER (0..65535)read-onlymandatory
snmpFddiPORTTable
OBJECT-TYPE
A list of PORT entries. The number of entries is given by the value of snmpFddiPORTNumber.
1.3.6.1.2.1.10.15.4.2not-accessiblemandatory
snmpFddiPORTEntry
OBJECT-TYPE
A PORT entry containing information common to a given PORT.
1.3.6.1.2.1.10.15.4.2.1not-accessiblemandatory
snmpFddiPORTSMTIndex
OBJECT-TYPE
The value of the SMT index associated with this PORT.
1.3.6.1.2.1.10.15.4.2.1.1INTEGER (1..65535)read-onlymandatory
snmpFddiPORTIndex
OBJECT-TYPE
A unique value for each PORT within a given SMT. Its value ranges between 1 and the sum of the values of snmpFddiSMTNonMasterCt { snmpFddiSMTEntry 6 } and snmpFddiSMTMasterCt { snmpFddiSMTEntry 7 } on the given SMT. The value for each PORT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.4.2.1.2INTEGER (1..65535)read-onlymandatory
snmpFddiPORTPCType
OBJECT-TYPE
PC_Type (refer to ANSI SMT 9.2.2 and ANSI SMT 9.6.3.2).
1.3.6.1.2.1.10.15.4.2.1.3INTEGER {a(1), b(2), s(3), m(4)}read-onlymandatory
snmpFddiPORTPCNeighbor
OBJECT-TYPE
The type (PC_Neighbor) of the remote PORT that is determined in PC_Signaling in R_Val (1,2) (refer to ANSI SMT 9.6.3.2).
1.3.6.1.2.1.10.15.4.2.1.4INTEGER {a(1), b(2), s(3), m(4), unknown(5)}read-onlymandatory
snmpFddiPORTConnectionPolicies
OBJECT-TYPE
A value that indicates the node's PORT policies. Pc-MAC-LCT, Pc-MAC-Loop, and Pc-MAC-Placement indicate how the respective PC Signaling Capability flags should be set (refer to ANSI SMT 9.4.3.2). The value is a sum. This value initially takes the value zero, then for each PORT policy, 2 raised to a power is added to the sum. The powers are according to the following table: Policy Power Pc-MAC-LCT 0 Pc-MAC-Loop 1 Pc-MAC-Placement 2
1.3.6.1.2.1.10.15.4.2.1.5INTEGER (0..7)read-writemandatory
snmpFddiPORTRemoteMACIndicated
OBJECT-TYPE
The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R_Val (9) (refer to ANSI SMT 9.6.3.2).
1.3.6.1.2.1.10.15.4.2.1.6INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiPORTCEState
OBJECT-TYPE
Indicates the current state of PORT's Configuration Element (CE) (refer to ANSI 9.7.5). Note that this value represents the Current Path information for this PORT.
1.3.6.1.2.1.10.15.4.2.1.7INTEGER {ce0(1), ce1(2), ce2(3), ce3(4), ce4(5)}read-onlymandatory
snmpFddiPORTPathsRequested
OBJECT-TYPE
A value that indicates the desired association(s) of the port with a station PATH. The 'Primary' Path is the default. The value of 'Secondary' is only meaningful for S (slave) or M (master) PORT PC-Types. This value effects the setting of the CF_Insert_S, and CF_Insert_L flags (refer to ANSI Section 9.4.3). If the 'Primary' PATH is present, then the Primary PATH (the default PATH) is selected. If the 'Secondary' PATH is present and the 'Primary' PATH is not present, then the CF_Insert_S flag is set. If the 'Local' PATH is sent and neither the 'Primary' or 'Secondary' PATHs are sent, then the CF_Insert_L flag is set. The value is a sum. This value initially takes the value zero, then for each type of PATH desired, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2 Isolated 3
1.3.6.1.2.1.10.15.4.2.1.8INTEGER (0..15)read-writemandatory
snmpFddiPORTMACPlacement
OBJECT-TYPE
Indicates the upstream MAC, if any, that is associated with the PORT. The value shall be zero if there is no MAC associated with the PORT. Otherwise, the value shall be equal to the value of snmpFddiMACIndex associated with the MAC.
1.3.6.1.2.1.10.15.4.2.1.9FddiResourceIdread-onlymandatory
snmpFddiPORTAvailablePaths
OBJECT-TYPE
A value that indicates the PATH types available for M and S PORTs. The value is a sum. This value initially takes the value zero, then for each type of PATH that this port has available, 2 raised to a power is added to the sum. The powers are according to the following table: Path Power Primary 0 Secondary 1 Local 2
1.3.6.1.2.1.10.15.4.2.1.10INTEGER (0..7)read-onlymandatory
snmpFddiPORTMACLoopTime
OBJECT-TYPE
Time for the optional MAC Local Loop, T_Next(9), which is greater-than or equal-to 200 milliseconds (refer to ANSI SMT 9.4.4.2.3).
1.3.6.1.2.1.10.15.4.2.1.11FddiTimeread-writemandatory
snmpFddiPORTTBMax
OBJECT-TYPE
TB_Max (refer to ANSI SMT 9.4.4.2.1).
1.3.6.1.2.1.10.15.4.2.1.12FddiTimeread-writemandatory
snmpFddiPORTBSFlag
OBJECT-TYPE
The Break State, BS_Flag (refer to ANSI SMT 9.4.3.4).
1.3.6.1.2.1.10.15.4.2.1.13INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiPORTLCTFailCts
OBJECT-TYPE
The count of the consecutive times the link confidence test (LCT) has failed during connection management (refer to ANSI 9.4.1).
1.3.6.1.2.1.10.15.4.2.1.14Counterread-onlymandatory
snmpFddiPORTLerEstimate
OBJECT-TYPE
A long term average link error rate. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate.
1.3.6.1.2.1.10.15.4.2.1.15INTEGER (4..15)read-onlymandatory
snmpFddiPORTLemRejectCts
OBJECT-TYPE
A link error monitoring count of the times that a link has been rejected.
1.3.6.1.2.1.10.15.4.2.1.16Counterread-onlymandatory
snmpFddiPORTLemCts
OBJECT-TYPE
The aggregate link error monitor error count, set to zero only on station power_up.
1.3.6.1.2.1.10.15.4.2.1.17Counterread-onlymandatory
snmpFddiPORTLerCutoff
OBJECT-TYPE
The link error rate estimate at which a link connection will be broken. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent.
1.3.6.1.2.1.10.15.4.2.1.18INTEGER (4..15)read-writemandatory
snmpFddiPORTLerAlarm
OBJECT-TYPE
The link error rate estimate at which a link connection will generate an alarm. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate.
1.3.6.1.2.1.10.15.4.2.1.19INTEGER (4..15)read-writemandatory
snmpFddiPORTConnectState
OBJECT-TYPE
An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4 (Next) || PC5 (Signal) || PC6 (Join) || PC7 (Verify)) && (PC_Withhold = None) standby: (NOT PC_Withhold == None) active: (PC2:Trace || PC8:Active)
1.3.6.1.2.1.10.15.4.2.1.20INTEGER {disabled(1), connecting(2), standby(3), active(4)}read-onlymandatory
snmpFddiPORTPCMState
OBJECT-TYPE
(refer to SMT 9.6.2).
1.3.6.1.2.1.10.15.4.2.1.21INTEGER {pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)}read-onlymandatory
snmpFddiPORTPCWithhold
OBJECT-TYPE
PC_Withhold, (refer to ANSI SMT 9.4.1).
1.3.6.1.2.1.10.15.4.2.1.22INTEGER {none(1), m-m(2), other(3)}read-onlymandatory
snmpFddiPORTLerCondition
OBJECT-TYPE
This variable is set to true whenever LerEstimate is less than or equal to LerAlarm.
1.3.6.1.2.1.10.15.4.2.1.23INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiPORTChipSet
OBJECT-TYPE
This object identifies the hardware chip(s) which is (are) principally responsible for the implementation of the PORT (PHY) function. A few OBJECT IDENTIFIERS are identified elsewhere in this memo. For those The assignment of additional OBJECT IDENTIFIERs to various types of hardware chip sets is managed by the IANA. For example, vendors whose chip sets are not defined in this memo may request a number from the Internet Assigned Numbers Authority (IANA) which indicates the assignment of a enterprise specific subtree which, among other things, may be used to allocate OBJECT IDENTIFIER assignments for that enterprise's chip sets. Similarly, in the absence of an appropriately assigned OBJECT IDENTIFIER in this memo or in an enterprise specific subtree of a chip vendor, a board or system vendor can request a number for a subtree from the IANA and make an appropriate assignment. It is desired that, whenever possible, the same OBJECT IDENTIFIER be used for all chips of a given type. Consequently, the assignment made in this memo for a chip, if any, should be used in preference to any other assignment and the assignment made by the chip manufacturer, if any, should be used in preference to assignments made by users of those chips. If the hardware chip set is unknown, the object identifier unknownChipSet OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownChipSet is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value.
1.3.6.1.2.1.10.15.4.2.1.24OBJECT IDENTIFIERread-onlymandatory
snmpFddiPORTAction
OBJECT-TYPE
This object, when read, always returns a value of other(1). The behavior of setting this variable to each of the acceptable values is as follows: Other: Results in a badValue error. maintPORT: Signal PC_Maint enablePORT: Signal PC_Enable disablePORT: Signal PC_Disable startPORT: Signal PC_Start stopPORT: Signal PC_Stop Signals cause an SM_CM_CONTROL.request service to be generated with a control_action of `Signal' and the `variable' parameter set with the appropriate value (i.e., PC_Maint, PC_Enable, PC_Disable, PC_Start, PC_Stop). Ref. ANSI SMT Section 9.3.2. Attempts to set this object to all other values results in a badValue error.
1.3.6.1.2.1.10.15.4.2.1.25INTEGER {other(1), maintPORT(2), enablePORT(3), disablePORT(4), startPORT(5), stopPORT(6)}read-writemandatory
snmpFddiATTACHMENT
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.5
snmpFddiATTACHMENTNumber
OBJECT-TYPE
The total number of attachments (across all SMTs) on this network management application entity. The value for this variable must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.5.1INTEGER (0..65535)read-onlymandatory
snmpFddiATTACHMENTTable
OBJECT-TYPE
A list of ATTACHMENT entries. The number of entries is given by the value of snmpFddiATTACHMENTNumber.
1.3.6.1.2.1.10.15.5.2not-accessiblemandatory
snmpFddiATTACHMENTEntry
OBJECT-TYPE
An ATTACHMENT entry containing information common to a given set of ATTACHMENTs. The ATTACHMENT Resource represents a PORT or a pair of PORTs plus the optional associated optical bypass that are managed as a functional unit. Because of its relationship to the PORT Objects, there is a natural association of ATTACHMENT Resource Indices to the PORT Indices. The resource index for the ATTACHMENT is equal to the associated PORT index for 'single-attachment' and 'concentrator' type snmpFddiATTACHMENTClasses. For 'dual-attachment' Classes, the ATTACHMENT Index is the PORT Index of the A PORT of the A/B PORT Pair that represents the ATTACHMENT.
1.3.6.1.2.1.10.15.5.2.1not-accessiblemandatory
snmpFddiATTACHMENTSMTIndex
OBJECT-TYPE
The value of the SMT index associated with this ATTACHMENT.
1.3.6.1.2.1.10.15.5.2.1.1INTEGER (1..65535)read-onlymandatory
snmpFddiATTACHMENTIndex
OBJECT-TYPE
A unique value for each ATTACHMENT on a given SMT. Its value ranges between 1 and the sum of the values of snmpFddiSMTNonMasterCt { snmpFddiSMTEntry 6 } and snmpFddiSMTMasterCt { snmpFddiSMTEntry 7 } on the given SMT. The value for each ATTACHMENT must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
1.3.6.1.2.1.10.15.5.2.1.2INTEGER (1..65535)read-onlymandatory
snmpFddiATTACHMENTClass
OBJECT-TYPE
The Attachment class. This represents a PORT or a pair of PORTs plus the associated optional optical bypass that are managed as a functional unit. The PORT associations are the following: single-attachment - S PORTs dual-attachment - A/B PORT Pairs concentrator - M PORTs
1.3.6.1.2.1.10.15.5.2.1.3INTEGER {single-attachment(1), dual-attachment(2), concentrator(3)}read-onlymandatory
snmpFddiATTACHMENTOpticalBypassPresent
OBJECT-TYPE
The value of this value is false for 'single- attachment' and { snmpFddiATTACHMENT 11 }. Correct operation of CMT for single-attachment and concentrator attachments requires that a bypass function must not loopback the network side of the MIC, but only the node side.
1.3.6.1.2.1.10.15.5.2.1.4INTEGER {true(1), false(2)}read-onlymandatory
snmpFddiATTACHMENTIMaxExpiration
OBJECT-TYPE
I_Max (refer to ANSI SMT 9.4.4.2.1). It is recognized that some currently deployed systems do not implement an optical bypass. Systems which do not implement optical bypass should return a value of 0.
1.3.6.1.2.1.10.15.5.2.1.5FddiTimeread-onlymandatory
snmpFddiATTACHMENTInsertedStatus
OBJECT-TYPE
Indicates whether the attachment is currently inserted in the node.
1.3.6.1.2.1.10.15.5.2.1.6INTEGER {true(1), false(2), unimplemented(3)}read-onlymandatory
snmpFddiATTACHMENTInsertPolicy
OBJECT-TYPE
Indicates the Insert Policy for this Attachment. Insert: True (1), Don't Insert: False (2), Unimplemented (3)
1.3.6.1.2.1.10.15.5.2.1.7INTEGER {true(1), false(2), unimplemented(3)}read-writemandatory
snmpFddiChipSets
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.6
snmpFddiPHYChipSets
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.6.1
snmpFddiMACChipSets
OBJECT-IDENTITY
1.3.6.1.2.1.10.15.6.2
snmpFddiPHYMACChipSets
OBJECT-IDENTITY