MIBs Depot

RFC1230-MIB

Registered at
1.3.6.1.3.7
Namespace
standard
Source file
RFC1230-MIB
Digest
sha256:ad6e00c008264b0096a7ccde4f591f20ae67fb61c46068332c34b19feb9eb135

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, experimental, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

RFC1230-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
MacAddress
type
OctetTime
type

Objects

NameOIDSyntaxAccessStatus
dot4
OBJECT-IDENTITY
1.3.6.1.3.7
dot4Table
OBJECT-TYPE
This table contains Token Bus interface parameters and state variables, one entry per 802.5 interface.
1.3.6.1.3.7.1not-accessiblemandatory
dot4Entry
OBJECT-TYPE
A list of Token Bus status and operational parameter values for an 802.4 interface.
1.3.6.1.3.7.1.1not-accessiblemandatory
dot4IfIndex
OBJECT-TYPE
The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
1.3.6.1.3.7.1.1.1INTEGERread-onlymandatory
dot4Options
OBJECT-TYPE
The optional parts of the 802.4 specification which are in use by this station. The options of the 802.4 specification are represented by the following values: 1 - Priority 2 - Request-With-Response The value of this object is given by the sum of the above representations for those options in use on this interface. The value zero indicates that no options are in use.
1.3.6.1.3.7.1.1.2INTEGERread-onlymandatory
dot4State
OBJECT-TYPE
The current state of the 802.4 interface. The value of other(1) is used if the state is unknown (e.g., due to an error condition).
1.3.6.1.3.7.1.1.3INTEGER {other(1), offline(2), outOfRing(3), enteringRing(4), inRing(5)}read-onlymandatory
dot4Commands
OBJECT-TYPE
Setting this object causes the station to change the state of the interface as indicated by the specified value. An initialize(5) command causes the interfaceto load its operational parameters from its initialization parameters; the value of dot4InitInRingDesired determines whether the station tries to enter the logical ring immediately. Note that the 802.4 specification suggests a station remain Offline after a 'remote Network Management' reset(4), until a 'local Network Management' initialize(5) is performed. Setting this object to a value of no-op(1) has no effect. When read, this object always has the value no-op(1).
1.3.6.1.3.7.1.1.4INTEGER {no-op(1), enterRing(2), exitRing(3), reset(4), initialize(5)}read-writemandatory
dot4MacAddrLen
OBJECT-TYPE
This object indicates the size of MAC addresses interpreted by this station.
1.3.6.1.3.7.1.1.5INTEGER {sixteenBit(1), forty-eightBit(2)}read-onlymandatory
dot4NextStation
OBJECT-TYPE
The MAC address of this station's successor in the logical ring.
1.3.6.1.3.7.1.1.6MacAddressread-onlymandatory
dot4PreviousStation
OBJECT-TYPE
The source MAC address of the last token addressed to this station.
1.3.6.1.3.7.1.1.7MacAddressread-onlymandatory
dot4SlotTime
OBJECT-TYPE
The maximum time any station need wait for an immediate MAC-level response from another station. This value must the same in all stations on the 802.4 network.
1.3.6.1.3.7.1.1.8OctetTimeread-onlymandatory
dot4LastTokenRotTime
OBJECT-TYPE
The observed token rotation time for the last token rotation, timed from token arrival to token arrival. A value of zero indicates that the token is not rotating.
1.3.6.1.3.7.1.1.9OctetTimeread-onlymandatory
dot4HiPriTokenHoldTime
OBJECT-TYPE
The maximum duration for which a station can hold the token to transmit frames of access class 6 (if the priority option is implemented), or of any access class (if the priority option is not implemented).
1.3.6.1.3.7.1.1.10OctetTimeread-onlymandatory
dot4TargetRotTimeClass4
OBJECT-TYPE
If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 4. The limit is measured from the time the station is able to start transmitting frames at this access class on one rotation, to the time it must stop transmitting frames at this access class on the next rotation. If the priority scheme is not being used, this object has the value 0.
1.3.6.1.3.7.1.1.11OctetTimeread-onlymandatory
dot4TargetRotTimeClass2
OBJECT-TYPE
If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 2. The limit is measured from the time the station is able to start transmitting frames at this access class on one rotation, to the time it must stop transmitting frames at this access class on the next rotation. If the priority scheme is not being used, this object has the value 0.
1.3.6.1.3.7.1.1.12OctetTimeread-onlymandatory
dot4TargetRotTimeClass0
OBJECT-TYPE
If the priority scheme is being used, this value specifies a limit on how long a station can transmit frames at access class 0. The limit is measured from the time the station is able to start transmitting frames at this access class on one rotation, to the time it must stop transmitting frames at this access class on the next rotation. If the priority scheme is not being used, this object has the value 0.
1.3.6.1.3.7.1.1.13OctetTimeread-onlymandatory
dot4TargetRotTimeRingMaint
OBJECT-TYPE
A value used to limit the duration of a token rotation. If the duration of a token rotation exceeds this value, the station will not open the response window to solicit for a new successor.
1.3.6.1.3.7.1.1.14OctetTimeread-onlymandatory
dot4RingMaintTimerInitValue
OBJECT-TYPE
The value to which the dot4TargetRotTimeRingMaint is set, each time the station enters the ring. A large value will cause the station to solicit successors immediately upon entry to the ring; a value of zero will cause the station to defer this solicitation for at least one token rotation.
1.3.6.1.3.7.1.1.15OctetTimeread-onlymandatory
dot4MaxInterSolicitCount
OBJECT-TYPE
The maximum number of consecutive token rotations without soliciting for a successor. If this count expires, the station opens the response window to solicit for a successor (providing the duration of the current token rotation has not exceeded dot4TargetRotTimeRingMaint). The least significant two bits of the count are determined randomly by the station on a per-use basis.
1.3.6.1.3.7.1.1.16INTEGER (16..255)read-onlymandatory
dot4MaxRetries
OBJECT-TYPE
The maximum number of retries of a Request-with-Response (RWR) frame. If the RWR option is not in use, this object has the value 0.
1.3.6.1.3.7.1.1.17INTEGER (0..7)read-onlymandatory
dot4MinPostSilencePreambLen
OBJECT-TYPE
The minimum number of octets of preamble on the first frame transmitted by this station after a period of 'transmitted' silence.
1.3.6.1.3.7.1.1.18INTEGERread-onlymandatory
dot4StandardRevision
OBJECT-TYPE
The Revision number of the 802.4 standard implemented by this station.
1.3.6.1.3.7.1.1.19INTEGER {rev2(2)}read-onlymandatory
dot4InitTable
OBJECT-TYPE
This table contains Token Bus initialization parameters, one entry per 802.4 interface.
1.3.6.1.3.7.2not-accessiblemandatory
dot4InitEntry
OBJECT-TYPE
A list of Token Bus initialization parameters for an 802.4 interface.
1.3.6.1.3.7.2.1not-accessiblemandatory
dot4InitIfIndex
OBJECT-TYPE
The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
1.3.6.1.3.7.2.1.1INTEGERread-onlymandatory
dot4InitSlotTime
OBJECT-TYPE
The value assigned to the object dot4SlotTime when the station is initialized.
1.3.6.1.3.7.2.1.2OctetTimeread-writemandatory
dot4InitMaxInterSolicitCount
OBJECT-TYPE
The value assigned to the object dot4MaxInterSolicitCount when the station is initialized.
1.3.6.1.3.7.2.1.3INTEGER (16..255)read-writemandatory
dot4InitMaxRetries
OBJECT-TYPE
The value assigned to the object dot4MaxRetries when the station is initialized.
1.3.6.1.3.7.2.1.4INTEGER (0..7)read-writemandatory
dot4InitHiPriTokenHoldTime
OBJECT-TYPE
The value assigned to the object dot4HiPriTokenHoldTime when the station is initialized.
1.3.6.1.3.7.2.1.5OctetTimeread-writemandatory
dot4InitTargetRotTimeClass4
OBJECT-TYPE
The value assigned to the object dot4TargetRotTimeClass4 when the station is initialized.
1.3.6.1.3.7.2.1.6OctetTimeread-writemandatory
dot4InitTargetRotTimeClass2
OBJECT-TYPE
The value assigned to the object dot4TargetRotTimeClass2 when the station is initialized.
1.3.6.1.3.7.2.1.7OctetTimeread-writemandatory
dot4InitTargetRotTimeClass0
OBJECT-TYPE
The value assigned to the object dot4TargetRotTimeClass0 when the station is initialized.
1.3.6.1.3.7.2.1.8OctetTimeread-writemandatory
dot4InitTargetRotTimeRingMaint
OBJECT-TYPE
The value assigned to the object dot4TargetRotTimeRingMaint when the station is initialized.
1.3.6.1.3.7.2.1.9OctetTimeread-writemandatory
dot4InitRingMaintTimerInitValue
OBJECT-TYPE
The value assigned to the object dot4RingMaintTimerInitValue when the station is initialized.
1.3.6.1.3.7.2.1.10OctetTimeread-writemandatory
dot4InitMinPostSilencePreambLen
OBJECT-TYPE
The value assigned to the object dot4MinPostSilencePreambLen when the station is initialized.
1.3.6.1.3.7.2.1.11INTEGERread-writemandatory
dot4InitInRingDesired
OBJECT-TYPE
This object determines whether the station will attempt to enter the logical ring immediately after initialization.
1.3.6.1.3.7.2.1.12INTEGER {inRing(1), outOfRing(2)}read-writemandatory
dot4StatsTable
OBJECT-TYPE
A table containing Token Bus statistics. All the statistics are defined using the syntax Counter as 32 bit wrap around counters. Thus, if an interface's hardware chip set maintains these statistics in 16-bit counters, then the agent must read the hardware's counters frequently enough to prevent loss of significance, in order to maintain a 32-bit counter in software.
1.3.6.1.3.7.3not-accessiblemandatory
dot4StatsEntry
OBJECT-TYPE
An entry containing the 802.4 statistics for a particular interface.
1.3.6.1.3.7.3.1not-accessiblemandatory
dot4StatsIfIndex
OBJECT-TYPE
The value of this object identifies the 802.4 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
1.3.6.1.3.7.3.1.1INTEGERread-onlymandatory
dot4StatsTokenPasses
OBJECT-TYPE
The number of times this station has passed the token.
1.3.6.1.3.7.3.1.2Counterread-onlyoptional
dot4StatsTokenHeards
OBJECT-TYPE
The number of tokens heard by this station.
1.3.6.1.3.7.3.1.3Counterread-onlyoptional
dot4StatsNoSuccessors
OBJECT-TYPE
The number of times the station could not find a successor while believing itself not the only station in the ring. This can signify a faulty transmitter condition in this station.
1.3.6.1.3.7.3.1.4Counterread-onlymandatory
dot4StatsWhoFollows
OBJECT-TYPE
The number of times the station has had to look for a new next station.
1.3.6.1.3.7.3.1.5Counterread-onlymandatory
dot4StatsTokenPassFails
OBJECT-TYPE
The number of times the station failed in passing the token to the next station.
1.3.6.1.3.7.3.1.6Counterread-onlymandatory
dot4StatsNonSilences
OBJECT-TYPE
The number of occurrences of non-silence followed by silence in which a start delimiter was not detected.
1.3.6.1.3.7.3.1.7Counterread-onlymandatory
dot4StatsFcsErrors
OBJECT-TYPE
The number of frames received with an incorrect FCS and the E-bit reset.
1.3.6.1.3.7.3.1.8Counterread-onlymandatory
dot4StatsEbitErrors
OBJECT-TYPE
The number of frames the station received with the E-bit set in the end delimiter.
1.3.6.1.3.7.3.1.9Counterread-onlymandatory
dot4StatsFrameFrags
OBJECT-TYPE
The number of occurrences of receiving a start delimiter followed by another start delimiter, an invalid symbol sequence or silence, without an intervening end delimiter.
1.3.6.1.3.7.3.1.10Counterread-onlymandatory
dot4StatsFrameTooLongs
OBJECT-TYPE
The number of frames that were received that were larger than the media's MTU.
1.3.6.1.3.7.3.1.11Counterread-onlymandatory
dot4StatsOverRuns
OBJECT-TYPE
The number of times a FIFO overrun was detected in the station.
1.3.6.1.3.7.3.1.12Counterread-onlymandatory
dot4StatsDupAddresses
OBJECT-TYPE
The number of times this station detected another station using the same MAC address.
1.3.6.1.3.7.3.1.13Counterread-onlymandatory
dot4Errors
OBJECT-IDENTITY
1.3.6.1.3.7.4
dot4ModemInitFailed
OBJECT-IDENTITY
1.3.6.1.3.7.4.1
dot4Tests
OBJECT-IDENTITY
1.3.6.1.3.7.5
testFifoPath
OBJECT-IDENTITY
1.3.6.1.3.7.5.1
testExternalLoopback
OBJECT-IDENTITY
1.3.6.1.3.7.5.2
dot4ChipSets
OBJECT-IDENTITY
1.3.6.1.3.7.6
chipSetMc68824
OBJECT-IDENTITY
1.3.6.1.3.7.6.1