MIBs Depot

READYNAS-MIB

Registered at
1.3.6.1.4.1.4526.18
1.3.6.1.4.1.4526.100.12
Namespace
netgear
Source file
READYNAS-MIB
Digest
sha256:a25f1be646033251cae128619f7576cc076ba0a066346560f271afc9b99548d7

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

READYNAS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
netgear
OBJECT-IDENTITY
1.3.6.1.4.1.4526
nasManager
OBJECT-IDENTITY
1.3.6.1.4.1.4526.18
nasMgrSoftwareVersion
OBJECT-TYPE
Version information for the ReadyNAS NAS Manager software.
1.3.6.1.4.1.4526.18.1DisplayString (SIZE(1..32))read-onlycurrent
diskTable
OBJECT-TYPE
A table of physical disks attached to the NAS device.
1.3.6.1.4.1.4526.18.3not-accessiblemandatory
diskEntry
OBJECT-TYPE
An entry in the physical disk table.
1.3.6.1.4.1.4526.18.3.1not-accessiblemandatory
diskNumber
OBJECT-TYPE
Instance number of the disk entry.
1.3.6.1.4.1.4526.18.3.1.1INTEGERread-onlymandatory
diskChannel
OBJECT-TYPE
Channel number that the disk is connected to.
1.3.6.1.4.1.4526.18.3.1.2INTEGERread-onlymandatory
diskModel
OBJECT-TYPE
The disk drive's model name.
1.3.6.1.4.1.4526.18.3.1.3DisplayStringread-onlymandatory
diskState
OBJECT-TYPE
The current state of the Disk. Possible states: 0: Online 1: Offline
1.3.6.1.4.1.4526.18.3.1.4DisplayStringread-onlymandatory
diskTemperature
OBJECT-TYPE
temperature of this disk.
1.3.6.1.4.1.4526.18.3.1.5INTEGERread-onlymandatory
fanTable
OBJECT-TYPE
1.3.6.1.4.1.4526.18.4not-accessiblecurrent
fanEntry
OBJECT-TYPE
1.3.6.1.4.1.4526.18.4.1not-accessiblecurrent
fanNumber
OBJECT-TYPE
Instance number of this fan entry.
1.3.6.1.4.1.4526.18.4.1.1INTEGER (1..10000000)read-onlymandatory
fanRPM
OBJECT-TYPE
The current speed of the fan.
1.3.6.1.4.1.4526.18.4.1.2INTEGERread-onlymandatory
fanType
OBJECT-TYPE
What fan is used for: SYS: for system board CPU: for CPU CAS: for system case
1.3.6.1.4.1.4526.18.4.1.3DisplayStringread-onlymandatory
temperatureTable
OBJECT-TYPE
1.3.6.1.4.1.4526.18.5not-accessiblemandatory
temperatureEntry
OBJECT-TYPE
1.3.6.1.4.1.4526.18.5.1not-accessiblemandatory
temperatureNumber
OBJECT-TYPE
Instance number of this temperature probe entry.
1.3.6.1.4.1.4526.18.5.1.1INTEGERread-onlymandatory
temperatureValue
OBJECT-TYPE
The current temperature of this probe.
1.3.6.1.4.1.4526.18.5.1.2INTEGERread-onlymandatory
temperatureStatus
OBJECT-TYPE
The current temperature status.
1.3.6.1.4.1.4526.18.5.1.3DisplayStringread-onlymandatory
volumeTable
OBJECT-TYPE
A table of active volumes on the NAS device.
1.3.6.1.4.1.4526.18.7not-accessiblemandatory
volumeEntry
OBJECT-TYPE
An entry in the volume table.
1.3.6.1.4.1.4526.18.7.1not-accessiblemandatory
volumeNumber
OBJECT-TYPE
Instance number of the volume entry.
1.3.6.1.4.1.4526.18.7.1.1INTEGERread-onlymandatory
volumeName
OBJECT-TYPE
The name of the volume.
1.3.6.1.4.1.4526.18.7.1.2DisplayStringread-onlymandatory
volumeRAIDLevel
OBJECT-TYPE
The RAID level of the volume.
1.3.6.1.4.1.4526.18.7.1.3DisplayStringread-onlymandatory
volumeStatus
OBJECT-TYPE
The severity of the volume. Possible values: 1: Clean 2: Error 16: Initialized (Normal)
1.3.6.1.4.1.4526.18.7.1.4DisplayStringread-onlymandatory
volumeSize
OBJECT-TYPE
The size of the volume in megabytes.
1.3.6.1.4.1.4526.18.7.1.5INTEGERread-onlymandatory
volumeFreeSpace
OBJECT-TYPE
Free space on the volume in megabytes.
1.3.6.1.4.1.4526.18.7.1.6INTEGERread-onlymandatory
psuTable
OBJECT-TYPE
1.3.6.1.4.1.4526.18.8not-accessiblemandatory
psuEntry
OBJECT-TYPE
1.3.6.1.4.1.4526.18.8.1not-accessiblemandatory
psuNumber
OBJECT-TYPE
Instance number of this power supply unit.
1.3.6.1.4.1.4526.18.8.1.1INTEGERread-onlymandatory
psuDesc
OBJECT-TYPE
The description of this PSU.
1.3.6.1.4.1.4526.18.8.1.2DisplayStringread-onlymandatory
psuStatus
OBJECT-TYPE
The current PSU status.
1.3.6.1.4.1.4526.18.8.1.3DisplayStringread-onlymandatory
aryMgrEvts
OBJECT-IDENTITY
1.3.6.1.4.1.4526.18.200
controllerNameEv
OBJECT-TYPE
Controller Name for which trap is generated.
1.3.6.1.4.1.4526.18.200.201DisplayString (SIZE(1..64))read-onlymandatory
channelNumberEv
OBJECT-TYPE
Channel Number for which trap is generated.
1.3.6.1.4.1.4526.18.200.202INTEGER (0..3)read-onlymandatory
targetIDEv
OBJECT-TYPE
SCSI ID of the device for which trap is generated.
1.3.6.1.4.1.4526.18.200.203INTEGER (0..15)read-onlymandatory
virtualDiskNameEv
OBJECT-TYPE
Virtual Disk for which trap is generated.
1.3.6.1.4.1.4526.18.200.204DisplayString (SIZE(1..64))read-onlymandatory
arrayDiskNameEv
OBJECT-TYPE
Array Disk for which trap is generated.
1.3.6.1.4.1.4526.18.200.205DisplayString (SIZE(1..64))read-onlymandatory
oldVDConfigEv
OBJECT-TYPE
Current Virtual Disk configuration for which trap is generated
1.3.6.1.4.1.4526.18.200.206DisplayString (SIZE(1..128))read-onlymandatory
newVDConfigEv
OBJECT-TYPE
New Virtual Disk configuration for which trap is generated.
1.3.6.1.4.1.4526.18.200.207DisplayString (SIZE(1..128))read-onlymandatory
enclosureNumberEv
OBJECT-TYPE
Enclosure Number for which trap is generated.
1.3.6.1.4.1.4526.18.200.208INTEGERread-onlymandatory
unitNumberEv
OBJECT-TYPE
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
1.3.6.1.4.1.4526.18.200.209INTEGERread-onlymandatory
enclosureNameEv
OBJECT-TYPE
Enclosure Name for which trap is generated.
1.3.6.1.4.1.4526.18.200.210DisplayStringread-onlymandatory
unitNameEv
OBJECT-TYPE
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
1.3.6.1.4.1.4526.18.200.211DisplayStringread-onlymandatory
timeEv
OBJECT-TYPE
Amount of time specified in the trap message.
1.3.6.1.4.1.4526.18.200.212INTEGERread-onlymandatory
volumeNameEv
OBJECT-TYPE
Volume Drive Letter for which trap is generated.
1.3.6.1.4.1.4526.18.200.213DisplayStringread-onlymandatory
nasTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4526.18.300
fanFailureMesg
OBJECT-TYPE
Failure message for Fan
1.3.6.1.4.1.4526.18.400DisplayStringread-onlycurrent
tempFailureMesg
OBJECT-TYPE
Failure message for system temperature
1.3.6.1.4.1.4526.18.401DisplayStringread-onlycurrent
powerFailureMesg
OBJECT-TYPE
Failure message for system power
1.3.6.1.4.1.4526.18.402DisplayStringread-onlycurrent
raidMesg
OBJECT-TYPE
RAID hotplug event message
1.3.6.1.4.1.4526.18.403DisplayStringread-onlycurrent
snapshotMesg
OBJECT-TYPE
Snapshot messages
1.3.6.1.4.1.4526.18.404DisplayStringread-onlycurrent
upsMesg
OBJECT-TYPE
UPS status message
1.3.6.1.4.1.4526.18.405DisplayStringread-onlycurrent
sataMesg
OBJECT-TYPE
SATA hotplug event messages
1.3.6.1.4.1.4526.18.406DisplayStringread-onlycurrent
volumeMesg
OBJECT-TYPE
Disk usage warning
1.3.6.1.4.1.4526.18.407DisplayStringread-onlycurrent
diskTempWarningMesg
OBJECT-TYPE
Disk temperature warning messages
1.3.6.1.4.1.4526.18.408DisplayStringread-onlycurrent
backupMesg
OBJECT-TYPE
Backup job status messages
1.3.6.1.4.1.4526.18.409DisplayStringread-onlycurrent
smartMesg
OBJECT-TYPE
Disk SMART messages
1.3.6.1.4.1.4526.18.410DisplayStringread-onlycurrent
psuMesg
OBJECT-TYPE
PSU status messages
1.3.6.1.4.1.4526.18.411DisplayStringread-onlycurrent
productID
OBJECT-IDENTITY
1.3.6.1.4.1.4526.100
readyNAS
OBJECT-IDENTITY
1.3.6.1.4.1.4526.100.12

Notifications

NameOIDStatus
fanFailure
NOTIFICATION-TYPE
Fan failure, fan speed is %s.
1.3.6.1.4.1.4526.18.300.0.10
tempFailure
NOTIFICATION-TYPE
Temperature sensor reports out of normal range.
1.3.6.1.4.1.4526.18.300.0.20
powerVoltage
NOTIFICATION-TYPE
System power is out of spec, please check system status!
1.3.6.1.4.1.4526.18.300.0.30
raidEventNotice
NOTIFICATION-TYPE
RAID event detected!
1.3.6.1.4.1.4526.18.300.0.40
snapshotEventNotice
NOTIFICATION-TYPE
Snapshot event detected!
1.3.6.1.4.1.4526.18.300.0.50
hotplugDiskNotice
NOTIFICATION-TYPE
Hotplug disk event detected!
1.3.6.1.4.1.4526.18.300.0.60
upsEventNotice
NOTIFICATION-TYPE
UPS status.
1.3.6.1.4.1.4526.18.300.0.70
volumeNotice
NOTIFICATION-TYPE
Volume is approaching capacity.
1.3.6.1.4.1.4526.18.300.0.80
diskTempWarning
NOTIFICATION-TYPE
Disk temperature warning.
1.3.6.1.4.1.4526.18.300.0.90
backupNotice
NOTIFICATION-TYPE
Backup job status.
1.3.6.1.4.1.4526.18.300.0.100
diskSmartWarning
NOTIFICATION-TYPE
Disk SMART warning.
1.3.6.1.4.1.4526.18.300.0.110
psuWarning
NOTIFICATION-TYPE
Power supply unit warning.
1.3.6.1.4.1.4526.18.300.0.120