READYDATAOS-MIB
- Registered at
- 1.3.6.1.4.1.4526.221.3.6.1.4.1.4526.100.15
- Namespace
- netgear
- Source file
READYDATAOS-MIB- Digest
sha256:6650ca379931d3c1959c7ea1b4bc510ba36acc8d5edb30114abbc6e4558edd89
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
READYDATAOS-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| netgear OBJECT-IDENTITY | 1.3.6.1.4.1.4526 | |||
| ngNasManager OBJECT-IDENTITY | 1.3.6.1.4.1.4526.22 | |||
| nasMgrSoftwareVersion OBJECT-TYPE Version information for the ReadyDATAOS ngNasManager software. | 1.3.6.1.4.1.4526.22.1 | DisplayString (SIZE(1..32)) | read-only | current |
| diskTable OBJECT-TYPE A table of physical disks attached to the storage device. | 1.3.6.1.4.1.4526.22.3 | not-accessible | mandatory | |
| diskEntry OBJECT-TYPE An entry in the physical disk table. | 1.3.6.1.4.1.4526.22.3.1 | not-accessible | mandatory | |
| diskNumber OBJECT-TYPE Instance number of the disk entry. | 1.3.6.1.4.1.4526.22.3.1.1 | INTEGER | read-only | mandatory |
| diskID OBJECT-TYPE Disk ID. | 1.3.6.1.4.1.4526.22.3.1.2 | DisplayString | read-only | mandatory |
| diskSlotName OBJECT-TYPE The slot location of the disk. | 1.3.6.1.4.1.4526.22.3.1.3 | DisplayString | read-only | mandatory |
| diskSerial OBJECT-TYPE Disk Serial number. | 1.3.6.1.4.1.4526.22.3.1.4 | DisplayString | read-only | mandatory |
| diskModel OBJECT-TYPE The disk drive's model name. | 1.3.6.1.4.1.4526.22.3.1.5 | DisplayString | read-only | mandatory |
| ataError OBJECT-TYPE ATA error number for this disk from S.M.A.R.T read. | 1.3.6.1.4.1.4526.22.3.1.6 | INTEGER | read-only | mandatory |
| diskCapacity OBJECT-TYPE The capacity of the disk in bytes. | 1.3.6.1.4.1.4526.22.3.1.7 | DisplayString | read-only | mandatory |
| diskInterface OBJECT-TYPE The disk connect interface, such as SATA, USB etc. | 1.3.6.1.4.1.4526.22.3.1.8 | DisplayString | read-only | mandatory |
| diskState OBJECT-TYPE The current state of the Disk. Possible states: 0: Online 1: Offline | 1.3.6.1.4.1.4526.22.3.1.9 | DisplayString | read-only | mandatory |
| diskTemperature OBJECT-TYPE temperature of this disk(in Fahrenheit unit). | 1.3.6.1.4.1.4526.22.3.1.10 | INTEGER | read-only | mandatory |
| fanTable OBJECT-TYPE | 1.3.6.1.4.1.4526.22.4 | not-accessible | current | |
| fanEntry OBJECT-TYPE | 1.3.6.1.4.1.4526.22.4.1 | not-accessible | current | |
| fanNumber OBJECT-TYPE Instance number of this fan entry. | 1.3.6.1.4.1.4526.22.4.1.1 | INTEGER (1..10000000) | read-only | mandatory |
| fanRPM OBJECT-TYPE The current speed of the fan. | 1.3.6.1.4.1.4526.22.4.1.2 | INTEGER | read-only | mandatory |
| fanStatus OBJECT-TYPE The status of Fan | 1.3.6.1.4.1.4526.22.4.1.3 | DisplayString | read-only | mandatory |
| fanType OBJECT-TYPE What fan is used for: SYS: for system board CPU: for CPU CASE: for system case | 1.3.6.1.4.1.4526.22.4.1.4 | DisplayString | read-only | mandatory |
| temperatureTable OBJECT-TYPE | 1.3.6.1.4.1.4526.22.5 | not-accessible | mandatory | |
| temperatureEntry OBJECT-TYPE | 1.3.6.1.4.1.4526.22.5.1 | not-accessible | mandatory | |
| temperatureNumber OBJECT-TYPE Instance number of this temperature probe entry. | 1.3.6.1.4.1.4526.22.5.1.1 | INTEGER | read-only | mandatory |
| temperatureValue OBJECT-TYPE The current temperature of this probe (in Fahrenheit unit). | 1.3.6.1.4.1.4526.22.5.1.2 | INTEGER | read-only | mandatory |
| temperatureTyoe OBJECT-TYPE The current temperature refer to | 1.3.6.1.4.1.4526.22.5.1.3 | DisplayString | read-only | mandatory |
| temperatureMin OBJECT-TYPE The min temperature of this probe (in Fahrenheit unit). | 1.3.6.1.4.1.4526.22.5.1.4 | INTEGER | read-only | mandatory |
| temperatureMax OBJECT-TYPE The max temperature of this probe (in Fahrenheit unit). | 1.3.6.1.4.1.4526.22.5.1.5 | INTEGER | read-only | mandatory |
| volumeTable OBJECT-TYPE A table of active volumes on the storage device. | 1.3.6.1.4.1.4526.22.7 | not-accessible | mandatory | |
| volumeEntry OBJECT-TYPE An entry in the volume table. | 1.3.6.1.4.1.4526.22.7.1 | not-accessible | mandatory | |
| volumeNumber OBJECT-TYPE Instance number of the volume entry. | 1.3.6.1.4.1.4526.22.7.1.1 | INTEGER | read-only | mandatory |
| volumeName OBJECT-TYPE The name of the volume. | 1.3.6.1.4.1.4526.22.7.1.2 | DisplayString | read-only | mandatory |
| volumeRAIDLevel OBJECT-TYPE The RAID level of the volume. | 1.3.6.1.4.1.4526.22.7.1.3 | DisplayString | read-only | mandatory |
| volumeStatus OBJECT-TYPE The severity of the volume. Possible values: 1: ONLINE 2: OFFLINE 3: DEGRADED 4: FAULTED 5: REMOVED 6: UNAVAILABLE 7: UNKNOWN | 1.3.6.1.4.1.4526.22.7.1.4 | DisplayString | read-only | mandatory |
| volumeSize OBJECT-TYPE The size of the volume in megabytes. | 1.3.6.1.4.1.4526.22.7.1.5 | INTEGER | read-only | mandatory |
| volumeFreeSpace OBJECT-TYPE Free space on the volume in megabytes. | 1.3.6.1.4.1.4526.22.7.1.6 | INTEGER | read-only | mandatory |
| psuTable OBJECT-TYPE | 1.3.6.1.4.1.4526.22.8 | not-accessible | mandatory | |
| psuEntry OBJECT-TYPE | 1.3.6.1.4.1.4526.22.8.1 | read-only | mandatory | |
| psuNumber OBJECT-TYPE Instance number of this power supply unit. | 1.3.6.1.4.1.4526.22.8.1.1 | INTEGER | read-only | mandatory |
| psuDesc OBJECT-TYPE The description of this PSU. | 1.3.6.1.4.1.4526.22.8.1.2 | DisplayString | read-only | mandatory |
| psuStatus OBJECT-TYPE The current PSU status. | 1.3.6.1.4.1.4526.22.8.1.3 | DisplayString | read-only | mandatory |
| aryMgrEvts OBJECT-IDENTITY | 1.3.6.1.4.1.4526.22.200 | |||
| controllerNameEv OBJECT-TYPE Controller Name for which trap is generated. | 1.3.6.1.4.1.4526.22.200.201 | DisplayString (SIZE(1..64)) | read-only | mandatory |
| channelNumberEv OBJECT-TYPE Channel Number for which trap is generated. | 1.3.6.1.4.1.4526.22.200.202 | INTEGER (0..3) | read-only | mandatory |
| targetIDEv OBJECT-TYPE SCSI ID of the device for which trap is generated. | 1.3.6.1.4.1.4526.22.200.203 | INTEGER (0..15) | read-only | mandatory |
| virtualDiskNameEv OBJECT-TYPE Virtual Disk for which trap is generated. | 1.3.6.1.4.1.4526.22.200.204 | DisplayString (SIZE(1..64)) | read-only | mandatory |
| arrayDiskNameEv OBJECT-TYPE Array Disk for which trap is generated. | 1.3.6.1.4.1.4526.22.200.205 | DisplayString (SIZE(1..64)) | read-only | mandatory |
| oldVDConfigEv OBJECT-TYPE Current Virtual Disk configuration for which trap is generated | 1.3.6.1.4.1.4526.22.200.206 | DisplayString (SIZE(1..128)) | read-only | mandatory |
| newVDConfigEv OBJECT-TYPE New Virtual Disk configuration for which trap is generated. | 1.3.6.1.4.1.4526.22.200.207 | DisplayString (SIZE(1..128)) | read-only | mandatory |
| enclosureNumberEv OBJECT-TYPE Enclosure Number for which trap is generated. | 1.3.6.1.4.1.4526.22.200.208 | INTEGER | read-only | mandatory |
| unitNumberEv OBJECT-TYPE Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe) | 1.3.6.1.4.1.4526.22.200.209 | INTEGER | read-only | mandatory |
| enclosureNameEv OBJECT-TYPE Enclosure Name for which trap is generated. | 1.3.6.1.4.1.4526.22.200.210 | DisplayString | read-only | mandatory |
| unitNameEv OBJECT-TYPE Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe) | 1.3.6.1.4.1.4526.22.200.211 | DisplayString | read-only | mandatory |
| timeEv OBJECT-TYPE Amount of time specified in the trap message. | 1.3.6.1.4.1.4526.22.200.212 | INTEGER | read-only | mandatory |
| volumeNameEv OBJECT-TYPE Volume Drive Letter for which trap is generated. | 1.3.6.1.4.1.4526.22.200.213 | DisplayString | read-only | mandatory |
| nasTraps OBJECT-IDENTITY | 1.3.6.1.4.1.4526.22.300 | |||
| fanFailureMesg OBJECT-TYPE Failure message for Fan | 1.3.6.1.4.1.4526.22.400 | DisplayString | read-only | current |
| tempFailureMesg OBJECT-TYPE Failure message for system temperature | 1.3.6.1.4.1.4526.22.401 | DisplayString | read-only | current |
| powerVoltageMesg OBJECT-TYPE Failure message for system power | 1.3.6.1.4.1.4526.22.402 | DisplayString | read-only | current |
| raidEventNoticeMesg OBJECT-TYPE RAID hotplug event message | 1.3.6.1.4.1.4526.22.403 | DisplayString | read-only | current |
| snapshotEventNoticeMesg OBJECT-TYPE Snapshot messages | 1.3.6.1.4.1.4526.22.404 | DisplayString | read-only | current |
| upsEventNoticeMesg OBJECT-TYPE UPS status message | 1.3.6.1.4.1.4526.22.405 | DisplayString | read-only | current |
| hotplugDiskNoticeMesg OBJECT-TYPE Disk hotplug event messages | 1.3.6.1.4.1.4526.22.406 | DisplayString | read-only | current |
| volumeNoticeMesg OBJECT-TYPE Disk usage warning | 1.3.6.1.4.1.4526.22.407 | DisplayString | read-only | current |
| diskTempWarningMesg OBJECT-TYPE Disk temperature warning messages | 1.3.6.1.4.1.4526.22.408 | DisplayString | read-only | current |
| backupNoticeMesg OBJECT-TYPE Backup job status messages | 1.3.6.1.4.1.4526.22.409 | DisplayString | read-only | current |
| diskSmartWarningMesg OBJECT-TYPE Disk SMART messages | 1.3.6.1.4.1.4526.22.410 | DisplayString | read-only | current |
| psuWarningMesg OBJECT-TYPE PSU status messages | 1.3.6.1.4.1.4526.22.411 | DisplayString | read-only | current |
| productID OBJECT-IDENTITY | 1.3.6.1.4.1.4526.100 | |||
| ReadyDATAOS OBJECT-IDENTITY | 1.3.6.1.4.1.4526.100.15 |
Notifications
| Name | OID | Status |
|---|---|---|
| fanFailure NOTIFICATION-TYPE Fan failure, fan speed is %s. | 1.3.6.1.4.1.4526.22.300.0.10 | |
| tempFailure NOTIFICATION-TYPE Temperature sensor reports out of normal range. | 1.3.6.1.4.1.4526.22.300.0.20 | |
| powerVoltage NOTIFICATION-TYPE System power is out of spec, please check system status! | 1.3.6.1.4.1.4526.22.300.0.30 | |
| raidEventNotice NOTIFICATION-TYPE RAID event detected! | 1.3.6.1.4.1.4526.22.300.0.40 | |
| snapshotEventNotice NOTIFICATION-TYPE Snapshot event detected! | 1.3.6.1.4.1.4526.22.300.0.50 | |
| hotplugDiskNotice NOTIFICATION-TYPE Hotplug disk event detected! | 1.3.6.1.4.1.4526.22.300.0.60 | |
| upsEventNotice NOTIFICATION-TYPE UPS status. | 1.3.6.1.4.1.4526.22.300.0.70 | |
| volumeNotice NOTIFICATION-TYPE Volume is approaching capacity. | 1.3.6.1.4.1.4526.22.300.0.80 | |
| diskTempWarning NOTIFICATION-TYPE Disk temperature warning. | 1.3.6.1.4.1.4526.22.300.0.90 | |
| backupNotice NOTIFICATION-TYPE Backup job status. | 1.3.6.1.4.1.4526.22.300.0.100 | |
| diskSmartWarning NOTIFICATION-TYPE Disk SMART warning. | 1.3.6.1.4.1.4526.22.300.0.110 | |
| psuWarning NOTIFICATION-TYPE Power supply unit warning. | 1.3.6.1.4.1.4526.22.300.0.120 |