MIBs Depot

READYDATAOS-MIB

Registered at
1.3.6.1.4.1.4526.22
1.3.6.1.4.1.4526.100.15
Namespace
netgear
Source file
READYDATAOS-MIB
Digest
sha256:6650ca379931d3c1959c7ea1b4bc510ba36acc8d5edb30114abbc6e4558edd89

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

READYDATAOS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
netgear
OBJECT-IDENTITY
1.3.6.1.4.1.4526
ngNasManager
OBJECT-IDENTITY
1.3.6.1.4.1.4526.22
nasMgrSoftwareVersion
OBJECT-TYPE
Version information for the ReadyDATAOS ngNasManager software.
1.3.6.1.4.1.4526.22.1DisplayString (SIZE(1..32))read-onlycurrent
diskTable
OBJECT-TYPE
A table of physical disks attached to the storage device.
1.3.6.1.4.1.4526.22.3not-accessiblemandatory
diskEntry
OBJECT-TYPE
An entry in the physical disk table.
1.3.6.1.4.1.4526.22.3.1not-accessiblemandatory
diskNumber
OBJECT-TYPE
Instance number of the disk entry.
1.3.6.1.4.1.4526.22.3.1.1INTEGERread-onlymandatory
diskID
OBJECT-TYPE
Disk ID.
1.3.6.1.4.1.4526.22.3.1.2DisplayStringread-onlymandatory
diskSlotName
OBJECT-TYPE
The slot location of the disk.
1.3.6.1.4.1.4526.22.3.1.3DisplayStringread-onlymandatory
diskSerial
OBJECT-TYPE
Disk Serial number.
1.3.6.1.4.1.4526.22.3.1.4DisplayStringread-onlymandatory
diskModel
OBJECT-TYPE
The disk drive's model name.
1.3.6.1.4.1.4526.22.3.1.5DisplayStringread-onlymandatory
ataError
OBJECT-TYPE
ATA error number for this disk from S.M.A.R.T read.
1.3.6.1.4.1.4526.22.3.1.6INTEGERread-onlymandatory
diskCapacity
OBJECT-TYPE
The capacity of the disk in bytes.
1.3.6.1.4.1.4526.22.3.1.7DisplayStringread-onlymandatory
diskInterface
OBJECT-TYPE
The disk connect interface, such as SATA, USB etc.
1.3.6.1.4.1.4526.22.3.1.8DisplayStringread-onlymandatory
diskState
OBJECT-TYPE
The current state of the Disk. Possible states: 0: Online 1: Offline
1.3.6.1.4.1.4526.22.3.1.9DisplayStringread-onlymandatory
diskTemperature
OBJECT-TYPE
temperature of this disk(in Fahrenheit unit).
1.3.6.1.4.1.4526.22.3.1.10INTEGERread-onlymandatory
fanTable
OBJECT-TYPE
1.3.6.1.4.1.4526.22.4not-accessiblecurrent
fanEntry
OBJECT-TYPE
1.3.6.1.4.1.4526.22.4.1not-accessiblecurrent
fanNumber
OBJECT-TYPE
Instance number of this fan entry.
1.3.6.1.4.1.4526.22.4.1.1INTEGER (1..10000000)read-onlymandatory
fanRPM
OBJECT-TYPE
The current speed of the fan.
1.3.6.1.4.1.4526.22.4.1.2INTEGERread-onlymandatory
fanStatus
OBJECT-TYPE
The status of Fan
1.3.6.1.4.1.4526.22.4.1.3DisplayStringread-onlymandatory
fanType
OBJECT-TYPE
What fan is used for: SYS: for system board CPU: for CPU CASE: for system case
1.3.6.1.4.1.4526.22.4.1.4DisplayStringread-onlymandatory
temperatureTable
OBJECT-TYPE
1.3.6.1.4.1.4526.22.5not-accessiblemandatory
temperatureEntry
OBJECT-TYPE
1.3.6.1.4.1.4526.22.5.1not-accessiblemandatory
temperatureNumber
OBJECT-TYPE
Instance number of this temperature probe entry.
1.3.6.1.4.1.4526.22.5.1.1INTEGERread-onlymandatory
temperatureValue
OBJECT-TYPE
The current temperature of this probe (in Fahrenheit unit).
1.3.6.1.4.1.4526.22.5.1.2INTEGERread-onlymandatory
temperatureTyoe
OBJECT-TYPE
The current temperature refer to
1.3.6.1.4.1.4526.22.5.1.3DisplayStringread-onlymandatory
temperatureMin
OBJECT-TYPE
The min temperature of this probe (in Fahrenheit unit).
1.3.6.1.4.1.4526.22.5.1.4INTEGERread-onlymandatory
temperatureMax
OBJECT-TYPE
The max temperature of this probe (in Fahrenheit unit).
1.3.6.1.4.1.4526.22.5.1.5INTEGERread-onlymandatory
volumeTable
OBJECT-TYPE
A table of active volumes on the storage device.
1.3.6.1.4.1.4526.22.7not-accessiblemandatory
volumeEntry
OBJECT-TYPE
An entry in the volume table.
1.3.6.1.4.1.4526.22.7.1not-accessiblemandatory
volumeNumber
OBJECT-TYPE
Instance number of the volume entry.
1.3.6.1.4.1.4526.22.7.1.1INTEGERread-onlymandatory
volumeName
OBJECT-TYPE
The name of the volume.
1.3.6.1.4.1.4526.22.7.1.2DisplayStringread-onlymandatory
volumeRAIDLevel
OBJECT-TYPE
The RAID level of the volume.
1.3.6.1.4.1.4526.22.7.1.3DisplayStringread-onlymandatory
volumeStatus
OBJECT-TYPE
The severity of the volume. Possible values: 1: ONLINE 2: OFFLINE 3: DEGRADED 4: FAULTED 5: REMOVED 6: UNAVAILABLE 7: UNKNOWN
1.3.6.1.4.1.4526.22.7.1.4DisplayStringread-onlymandatory
volumeSize
OBJECT-TYPE
The size of the volume in megabytes.
1.3.6.1.4.1.4526.22.7.1.5INTEGERread-onlymandatory
volumeFreeSpace
OBJECT-TYPE
Free space on the volume in megabytes.
1.3.6.1.4.1.4526.22.7.1.6INTEGERread-onlymandatory
psuTable
OBJECT-TYPE
1.3.6.1.4.1.4526.22.8not-accessiblemandatory
psuEntry
OBJECT-TYPE
1.3.6.1.4.1.4526.22.8.1read-onlymandatory
psuNumber
OBJECT-TYPE
Instance number of this power supply unit.
1.3.6.1.4.1.4526.22.8.1.1INTEGERread-onlymandatory
psuDesc
OBJECT-TYPE
The description of this PSU.
1.3.6.1.4.1.4526.22.8.1.2DisplayStringread-onlymandatory
psuStatus
OBJECT-TYPE
The current PSU status.
1.3.6.1.4.1.4526.22.8.1.3DisplayStringread-onlymandatory
aryMgrEvts
OBJECT-IDENTITY
1.3.6.1.4.1.4526.22.200
controllerNameEv
OBJECT-TYPE
Controller Name for which trap is generated.
1.3.6.1.4.1.4526.22.200.201DisplayString (SIZE(1..64))read-onlymandatory
channelNumberEv
OBJECT-TYPE
Channel Number for which trap is generated.
1.3.6.1.4.1.4526.22.200.202INTEGER (0..3)read-onlymandatory
targetIDEv
OBJECT-TYPE
SCSI ID of the device for which trap is generated.
1.3.6.1.4.1.4526.22.200.203INTEGER (0..15)read-onlymandatory
virtualDiskNameEv
OBJECT-TYPE
Virtual Disk for which trap is generated.
1.3.6.1.4.1.4526.22.200.204DisplayString (SIZE(1..64))read-onlymandatory
arrayDiskNameEv
OBJECT-TYPE
Array Disk for which trap is generated.
1.3.6.1.4.1.4526.22.200.205DisplayString (SIZE(1..64))read-onlymandatory
oldVDConfigEv
OBJECT-TYPE
Current Virtual Disk configuration for which trap is generated
1.3.6.1.4.1.4526.22.200.206DisplayString (SIZE(1..128))read-onlymandatory
newVDConfigEv
OBJECT-TYPE
New Virtual Disk configuration for which trap is generated.
1.3.6.1.4.1.4526.22.200.207DisplayString (SIZE(1..128))read-onlymandatory
enclosureNumberEv
OBJECT-TYPE
Enclosure Number for which trap is generated.
1.3.6.1.4.1.4526.22.200.208INTEGERread-onlymandatory
unitNumberEv
OBJECT-TYPE
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
1.3.6.1.4.1.4526.22.200.209INTEGERread-onlymandatory
enclosureNameEv
OBJECT-TYPE
Enclosure Name for which trap is generated.
1.3.6.1.4.1.4526.22.200.210DisplayStringread-onlymandatory
unitNameEv
OBJECT-TYPE
Unit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)
1.3.6.1.4.1.4526.22.200.211DisplayStringread-onlymandatory
timeEv
OBJECT-TYPE
Amount of time specified in the trap message.
1.3.6.1.4.1.4526.22.200.212INTEGERread-onlymandatory
volumeNameEv
OBJECT-TYPE
Volume Drive Letter for which trap is generated.
1.3.6.1.4.1.4526.22.200.213DisplayStringread-onlymandatory
nasTraps
OBJECT-IDENTITY
1.3.6.1.4.1.4526.22.300
fanFailureMesg
OBJECT-TYPE
Failure message for Fan
1.3.6.1.4.1.4526.22.400DisplayStringread-onlycurrent
tempFailureMesg
OBJECT-TYPE
Failure message for system temperature
1.3.6.1.4.1.4526.22.401DisplayStringread-onlycurrent
powerVoltageMesg
OBJECT-TYPE
Failure message for system power
1.3.6.1.4.1.4526.22.402DisplayStringread-onlycurrent
raidEventNoticeMesg
OBJECT-TYPE
RAID hotplug event message
1.3.6.1.4.1.4526.22.403DisplayStringread-onlycurrent
snapshotEventNoticeMesg
OBJECT-TYPE
Snapshot messages
1.3.6.1.4.1.4526.22.404DisplayStringread-onlycurrent
upsEventNoticeMesg
OBJECT-TYPE
UPS status message
1.3.6.1.4.1.4526.22.405DisplayStringread-onlycurrent
hotplugDiskNoticeMesg
OBJECT-TYPE
Disk hotplug event messages
1.3.6.1.4.1.4526.22.406DisplayStringread-onlycurrent
volumeNoticeMesg
OBJECT-TYPE
Disk usage warning
1.3.6.1.4.1.4526.22.407DisplayStringread-onlycurrent
diskTempWarningMesg
OBJECT-TYPE
Disk temperature warning messages
1.3.6.1.4.1.4526.22.408DisplayStringread-onlycurrent
backupNoticeMesg
OBJECT-TYPE
Backup job status messages
1.3.6.1.4.1.4526.22.409DisplayStringread-onlycurrent
diskSmartWarningMesg
OBJECT-TYPE
Disk SMART messages
1.3.6.1.4.1.4526.22.410DisplayStringread-onlycurrent
psuWarningMesg
OBJECT-TYPE
PSU status messages
1.3.6.1.4.1.4526.22.411DisplayStringread-onlycurrent
productID
OBJECT-IDENTITY
1.3.6.1.4.1.4526.100
ReadyDATAOS
OBJECT-IDENTITY
1.3.6.1.4.1.4526.100.15

Notifications

NameOIDStatus
fanFailure
NOTIFICATION-TYPE
Fan failure, fan speed is %s.
1.3.6.1.4.1.4526.22.300.0.10
tempFailure
NOTIFICATION-TYPE
Temperature sensor reports out of normal range.
1.3.6.1.4.1.4526.22.300.0.20
powerVoltage
NOTIFICATION-TYPE
System power is out of spec, please check system status!
1.3.6.1.4.1.4526.22.300.0.30
raidEventNotice
NOTIFICATION-TYPE
RAID event detected!
1.3.6.1.4.1.4526.22.300.0.40
snapshotEventNotice
NOTIFICATION-TYPE
Snapshot event detected!
1.3.6.1.4.1.4526.22.300.0.50
hotplugDiskNotice
NOTIFICATION-TYPE
Hotplug disk event detected!
1.3.6.1.4.1.4526.22.300.0.60
upsEventNotice
NOTIFICATION-TYPE
UPS status.
1.3.6.1.4.1.4526.22.300.0.70
volumeNotice
NOTIFICATION-TYPE
Volume is approaching capacity.
1.3.6.1.4.1.4526.22.300.0.80
diskTempWarning
NOTIFICATION-TYPE
Disk temperature warning.
1.3.6.1.4.1.4526.22.300.0.90
backupNotice
NOTIFICATION-TYPE
Backup job status.
1.3.6.1.4.1.4526.22.300.0.100
diskSmartWarning
NOTIFICATION-TYPE
Disk SMART warning.
1.3.6.1.4.1.4526.22.300.0.110
psuWarning
NOTIFICATION-TYPE
Power supply unit warning.
1.3.6.1.4.1.4526.22.300.0.120