RAISECOM-POWERMONITOR-MIB
- Registered at
- 1.3.6.1.4.1.8886.1.24
- Last updated
- 2011-01-19 00:00
- Organization
- Raisecom, Inc.
- Namespace
- raisecom
- Source file
RAISECOM-POWERMONITOR-MIB- Digest
sha256:8a0398ef634ee3636d0893012416b85178139f006ba894088158ba04757aa3f7
Description
The initial revision of this MIB.
Contact
Raise Systems Postal: Beijing, China Tel: 86-010-82884499 E-mail: support@raisecom.com
Imports
| From | Symbols |
|---|---|
| RAISECOM-BASE-MIB | raisecomAgent |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
RAISECOM-BASE-MIB RAISECOM-POWERMONITOR-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| raisecomPowerMonitorNotification OBJECT-IDENTITY | 1.3.6.1.4.1.8886.1.24.1 | |||
| raisecomPowerMonitorMibObjects OBJECT-IDENTITY | 1.3.6.1.4.1.8886.1.24.2 | |||
| raisecomPowerMonitorStateTable OBJECT-TYPE Power monitor state table. | 1.3.6.1.4.1.8886.1.24.2.1 | not-accessible | current | |
| raisecomPowerMonitorStateEntry OBJECT-TYPE Power monitor state entry. | 1.3.6.1.4.1.8886.1.24.2.1.1 | not-accessible | current | |
| raisecomPowerIndex OBJECT-TYPE Specify the sequence number of Power. | 1.3.6.1.4.1.8886.1.24.2.1.1.1 | Unsigned32 | not-accessible | current |
| raisecomPowerSerialNumber OBJECT-TYPE specify the identical serial number of current power card,this string number will be set when device leaving factory | 1.3.6.1.4.1.8886.1.24.2.1.1.2 | OCTET STRING | read-only | current |
| raisecomPowerType OBJECT-TYPE Specify the current type of the power. ac(1) means the current power AC Input. dc(2) means the current power DC Input. | 1.3.6.1.4.1.8886.1.24.2.1.1.3 | INTEGER {ac(1), dc(2)} | read-only | current |
| raisecomPowerVoltReference OBJECT-TYPE Specify the reference of the volt value of Power. | 1.3.6.1.4.1.8886.1.24.2.1.1.4 | INTEGER | read-only | current |
| raisecomPowerVoltValue OBJECT-TYPE Specify the volt value of Power. | 1.3.6.1.4.1.8886.1.24.2.1.1.5 | INTEGER | read-only | current |
| raisecomPowerStatus OBJECT-TYPE The status of power alarm. | 1.3.6.1.4.1.8886.1.24.2.1.1.6 | INTEGER {offline(1), online(2), power-on(3)} | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| raisecomPowerVoltNormal NOTIFICATION-TYPE The trap notification occur when power-card value translating from abnormal to normal. | 1.3.6.1.4.1.8886.1.24.1.1 | current |
| raisecomPowerVoltAbnormal NOTIFICATION-TYPE The trap notification occur when power-card value translating from normal to abnormal. | 1.3.6.1.4.1.8886.1.24.1.2 | current |
| raisecomPowerStatusTrap NOTIFICATION-TYPE A raisecomPowerTrap trap is sent when a power alarm generate. | 1.3.6.1.4.1.8886.1.24.1.3 | current |
| raisecomDyingGaspTrap NOTIFICATION-TYPE Dying gasp. | 1.3.6.1.4.1.8886.1.24.1.4 | current |