MIBs Depot

RAISECOM-OPTICAL-MONITOR-MIB

Registered at
1.3.6.1.4.1.8886.1.9
Last updated
2006-06-06 00:00
Organization
Raisecom, Inc.
Revisions
2006-06-06 00:00
Namespace
raisecom
Source file
RAISECOM-OPTICAL-MONITOR-MIB
Digest
sha256:414fbd8e76c731f25b29d3f1e13030fd9efadf868c94907a1a08189d70282bd5

Description

This MIB module defines objects to monitor optical characteristics on the optical interfaces in a network element.

Contact

Raise Systems Postal: Beijing, China Tel: 86-010-82884499 E-mail: chenyu@raisecom.com

Imports

FromSymbols
IF-MIBifIndex
RAISECOM-BASE-MIBraisecomAgent
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
SWITCH-TCEnableVar

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
RAISECOM-BASE-MIB
RAISECOM-OPTICAL-MONITOR-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
SWITCH-TC

Textual conventions

NameOIDSyntaxAccessStatus
OpticalPMPeriod
TEXTUAL-CONVENTION
This value indicates the time period over which performance monitoring data has been collected.
current
OpticalParameterType
TEXTUAL-CONVENTION
This value indicates the optical parameter that is being monitored. Valid values are - temperature(1) supplyVoltage(2) biasCurrent(3) txOutputPower(4) receivedPower(5)
current
OpticalParameterValue
TEXTUAL-CONVENTION
The value of the optical parameter that is being monitored. The range of values varies depending on the type of optical parameter being monitored, as identified by a corresponding object with syntax OpticalParameterType. When the optical parameter being monitored is 'temperature', the supported range is from -32768 to 32768, in units of 1/256 degrees centigrade. Example: A value of 6016 represents a temperature reading of 23.5 degrees C. When the optical parameter being monitored is 'supplyVoltage', the supported range is from 0 to 65535, in units of 1/10 millivolts. Example: A value of 55000 represents a supplyVoltage reading of 5.5 V. When the optical parameter being monitored is 'biasCurrent', the supported range is from 0 to 65535, in units of 1/500 microamperes. Example: A value of 500 represents a bias current reading of 1 microamperes. When the optical parameter being monitored is 'txOutputPower', the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm. Example: A value of 60000 represents a txOutputPower reading of 7.78 dBm. When the optical parameter being monitored is 'receivedPower', the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm. Example: A value of 60000 represents a receivedPower reading of 7.78 dBm.
current

Objects

NameOIDSyntaxAccessStatus
raisecomOpticalMonitorMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.1
raisecomOpticalMonGroup
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.1.1
raisecomOpticalMonTable
OBJECT-TYPE
This table provides objects to monitor optical parameters in a network element.
1.3.6.1.4.1.8886.1.9.1.1.1not-accessiblecurrent
raisecomOpticalMonEntry
OBJECT-TYPE
An entry in the raisecomOpticalMonTable provides objects to monitor an optical parameter at an optical interface.
1.3.6.1.4.1.8886.1.9.1.1.1.1not-accessiblecurrent
raisecomOpticalMonParameterType
OBJECT-TYPE
This object specifies the optical parameter that is being monitored in this entry.
1.3.6.1.4.1.8886.1.9.1.1.1.1.1OpticalParameterTypenot-accessiblecurrent
raisecomOpticalParameterValue
OBJECT-TYPE
This object gives the value measured for the particular optical parameter specified by the raisecomOpticalMonParameterType object.
1.3.6.1.4.1.8886.1.9.1.1.1.1.2OpticalParameterValueread-onlycurrent
raisecomOpticalParamHighAlarmThresh
OBJECT-TYPE
This object gives the high alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by raisecomOpticalParameterValue goes from below the value of this object to above the value of this object, or if the initial value of raisecomOpticalParameterValue exceeds the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object.
1.3.6.1.4.1.8886.1.9.1.1.1.1.3OpticalParameterValueread-onlycurrent
raisecomOpticalParamHighWarningThresh
OBJECT-TYPE
This object is used to set a high warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by raisecomOpticalParameterValue goes from below the value of this object to above the value of this object, or if the initial value of raisecomOpticalParameterValue exceeds the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object.
1.3.6.1.4.1.8886.1.9.1.1.1.1.4OpticalParameterValueread-onlycurrent
raisecomOpticalParamLowAlarmThresh
OBJECT-TYPE
This object is used to set a low alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by raisecomOpticalParameterValue goes from above the value of this object to below the value of this object, or if the initial value of raisecomOpticalParameterValue is lower than the value of this object. This alarm will be indicated in the raisecomOpticalParamAlarmStatus object ..
1.3.6.1.4.1.8886.1.9.1.1.1.1.5OpticalParameterValueread-onlycurrent
raisecomOpticalParamLowWarningThresh
OBJECT-TYPE
This object is used to set a low warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by raisecomOpticalParameterValue goes from above the value of this object to below the value of this object, or if the initial value of raisecomOpticalParameterValue object is lower than the value of this object. For network elements in the status indications, this threshold violation will be indicated in the raisecomOpticalParamAlarmStatus object .
1.3.6.1.4.1.8886.1.9.1.1.1.1.6OpticalParameterValueread-onlycurrent
raisecomOpticalParamAlarmStatus
OBJECT-TYPE
This object is used to indicate the current status of the thresholds for the monitored optical parameter on the interface. If a threshold is currently being exceeded on the interface, the object will be set. Otherwise, the object will be set to 0.
1.3.6.1.4.1.8886.1.9.1.1.1.1.7INTEGER {none(0), high-alarm-threshold(1), high-warning-threshold(2), low-alarm-threshold(3), low-warning-threshold(4)}read-onlycurrent
raisecomOpticalParamAlarmLastValue
OBJECT-TYPE
This object indicates the optical parameter value at the last time a threshold related to a particular optical parameter was exceeded on the interface. If no threshold value is currently being exceeded, then the value '-1000000' is returned.
1.3.6.1.4.1.8886.1.9.1.1.1.1.8OpticalParameterValueread-onlycurrent
raisecomOpticalParamAlarmLastChange
OBJECT-TYPE
This object specifies the value of sysUpTime at the last time a threshold related to a particular optical parameter was exceeded on the interface.
1.3.6.1.4.1.8886.1.9.1.1.1.1.9TimeTicksread-onlycurrent
raisecomOpticalMon15MinValidIntervals
OBJECT-TYPE
This object gives the number of previous 15 minute intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be n (where n is the maximum number of 15 minute intervals supported at this interface), unless the measurement was (re-)started within the last (nx15) minutes, in which case the value will be the number of previous 15 minute intervals for which the agent has some data.
1.3.6.1.4.1.8886.1.9.1.1.1.1.10Unsigned32 (0..96)read-onlycurrent
raisecomOpticalMon24HrValidIntervals
OBJECT-TYPE
This object gives the number of previous 24 hour intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be 0 if the measurement was (re-)started within the last 24 hours, or 1 otherwise.
1.3.6.1.4.1.8886.1.9.1.1.1.1.11Unsigned32 (0..1)read-onlycurrent
raisecomOpticalMonValidStatus
OBJECT-TYPE
This object indicates the parameter row is valid or not.
1.3.6.1.4.1.8886.1.9.1.1.1.1.12INTEGER {valid(1), invalid(2)}read-onlycurrent
raisecomOpticalNotifyEnable
OBJECT-TYPE
This object specifies the generation of raisecomOpticalMonParameterStatus notifications.
1.3.6.1.4.1.8886.1.9.1.1.2EnableVarread-writecurrent
raisecomOpticalDigitalDiagnoticEnable
OBJECT-TYPE
Enable or disable digitaldiagnotic on the switch.
1.3.6.1.4.1.8886.1.9.1.1.3EnableVarread-writecurrent
raisecomOpticalPMGroup
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.1.2
raisecomOpticalPMCurrentTable
OBJECT-TYPE
This table contains performance monitoring data for the various optical parameters, collected over the current 15 minute or the current 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.1not-accessiblecurrent
raisecomOpticalPMCurrentEntry
OBJECT-TYPE
An entry in the raisecomOpticalPMCurrentTable. It contains performance monitoring data for a monitored optical parameter at an interface, collected over the current 15 minute or the current 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.1.1not-accessiblecurrent
raisecomOpticalPMCurrentPeriod
OBJECT-TYPE
This object indicates whether the optical parameter values given in this entry are collected over the current 15 minute or the current 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.1.1.1OpticalPMPeriodnot-accessiblecurrent
raisecomOpticalPMCurrentParamType
OBJECT-TYPE
This object specifies the optical parameter that is being monitored, in this entry.
1.3.6.1.4.1.8886.1.9.1.2.1.1.2OpticalParameterTypenot-accessiblecurrent
raisecomOpticalPMCurrentMaxParam
OBJECT-TYPE
This object gives the maximum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.1.1.3OpticalParameterValueread-onlycurrent
raisecomOpticalPMCurrentMinParam
OBJECT-TYPE
This object gives the minimum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.1.1.4OpticalParameterValueread-onlycurrent
raisecomOpticalPMCurrentMeanParam
OBJECT-TYPE
This object gives the average value of the monitored optical parameter, in the current 15 minute or the current 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.1.1.5OpticalParameterValueread-onlycurrent
raisecomOpticalPMIntervalTable
OBJECT-TYPE
This table stores performance monitoring data for the various optical parameters, collected over previous intervals. This table can have entries for one complete 24 hour interval and up to 96 complete 15 minute intervals. A system is required to store at least 4 completed 15 minute intervals. The number of valid 15 minute intervals in this table is indicated by the cOpticalMon15MinValidIntervals object and the number of valid 24 hour intervals is indicated by the cOpticalMon24HrValidIntervals object.
1.3.6.1.4.1.8886.1.9.1.2.2not-accessiblecurrent
raisecomOpticalPMIntervalEntry
OBJECT-TYPE
An entry in the raisecomOpticalPMIntervalTable. It contains performance monitoring data for an optical parameter, collected over a previous interval.
1.3.6.1.4.1.8886.1.9.1.2.2.1not-accessiblecurrent
raisecomOpticalPMIntervalPeriod
OBJECT-TYPE
This object indicates whether the optical parameter values, given in this entry, are collected over a period of 15 minutes or 24 hours.
1.3.6.1.4.1.8886.1.9.1.2.2.1.1OpticalPMPeriodnot-accessiblecurrent
raisecomOpticalPMIntervalNumber
OBJECT-TYPE
A number between 1 and 96, which identifies the interval for which the set of optical parameter values is available. The interval identified by 1 is the most recently completed 15 minute or 24 hour interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
1.3.6.1.4.1.8886.1.9.1.2.2.1.2Integer32 (1..96)not-accessiblecurrent
raisecomOpticalPMIntervalParamType
OBJECT-TYPE
This object specifies the optical parameter that is being monitored, in this entry.
1.3.6.1.4.1.8886.1.9.1.2.2.1.3OpticalParameterTypenot-accessiblecurrent
raisecomOpticalPMIntervalMaxParam
OBJECT-TYPE
This object gives the maximum value measured for the optical parameter, in a particular 15 minute or 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.2.1.4OpticalParameterValueread-onlycurrent
raisecomOpticalPMIntervalMinParam
OBJECT-TYPE
This object gives the minimum value measured for the optical parameter, in a particular 15 minute or 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.2.1.5OpticalParameterValueread-onlycurrent
raisecomOpticalPMIntervalMeanParam
OBJECT-TYPE
This object gives the average value of the measured optical parameter, in a particular 15 minute or 24 hour interval.
1.3.6.1.4.1.8886.1.9.1.2.2.1.6OpticalParameterValueread-onlycurrent
raisecomTranceiverInfoTable
OBJECT-TYPE
Trancetver information Table.
1.3.6.1.4.1.8886.1.9.1.4not-accessiblecurrent
raisecomTranceiverInfoEntry
OBJECT-TYPE
An entry in the raisecomSfpAccessA0Table.
1.3.6.1.4.1.8886.1.9.1.4.1not-accessiblecurrent
raisecomTranceiverType
OBJECT-TYPE
Type of the interface, such as 1000_BASE_SX_SFP
1.3.6.1.4.1.8886.1.9.1.4.1.1OCTET STRINGread-onlycurrent
raisecomTranceiverConnectorType
OBJECT-TYPE
ConnectorType of the interface, such as SC/LC
1.3.6.1.4.1.8886.1.9.1.4.1.2OCTET STRINGread-onlycurrent
raisecomTranceiverWavelength
OBJECT-TYPE
Wavelength of the interface, measured in nm.
1.3.6.1.4.1.8886.1.9.1.4.1.3Integer32read-onlycurrent
raisecomTranceiverVendorName
OBJECT-TYPE
Vendor name of the interface.
1.3.6.1.4.1.8886.1.9.1.4.1.4OCTET STRINGread-onlycurrent
raisecomTranceiverVendorPN
OBJECT-TYPE
Vendor part number of the interface.
1.3.6.1.4.1.8886.1.9.1.4.1.5OCTET STRINGread-onlycurrent
raisecomTranceiverVendorSN
OBJECT-TYPE
Vendor serial number of the interface.
1.3.6.1.4.1.8886.1.9.1.4.1.6OCTET STRINGread-onlycurrent
raisecomTransceiverFiberType
OBJECT-TYPE
Types of the fiber, single_mode, multi_mode, none.
1.3.6.1.4.1.8886.1.9.1.4.1.7INTEGER {single-mode(1), multi-mode(2), none(3)}read-onlycurrent
raisecomTransceiverTransferDistance
OBJECT-TYPE
The max distance which the interface could transmit, measured in meter.
1.3.6.1.4.1.8886.1.9.1.4.1.8Integer32read-onlycurrent
raisecomOpticalMonitorMIBNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.2
raisecomOpticalMonitorMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.3
raisecomOpticalMonitorMIBCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.3.1
raisecomOpticalMonitorMIBGroups
OBJECT-IDENTITY
1.3.6.1.4.1.8886.1.9.3.2

Notifications

NameOIDStatus
raisecomOpticalMonParameterStatus
NOTIFICATION-TYPE
This notification is sent when any threshold related to an optical parameter is exceeded on an interface. This notification may be suppressed under the following conditions: - depending on the value of the raisecomOpticalNotifyEnable object.
1.3.6.1.4.1.8886.1.9.2.1current

Conformance

NameOIDStatus
raisecomOpticalMonitorMIBCompliance
MODULE-COMPLIANCE
The compliance statement for network elements that monitor optical characteristics and thresholds on the optical interfaces in a network element.
1.3.6.1.4.1.8886.1.9.3.1.1current
raisecomOpticalMIBMonGroup
OBJECT-GROUP
A mandatory object that provides monitoring of optical characteristics.
1.3.6.1.4.1.8886.1.9.3.2.1current
raisecomOpticalMIBThresholdGroup
OBJECT-GROUP
A collection of objects that support thresholds on optical parameters and provide status information when the thresholds are exceeded .
1.3.6.1.4.1.8886.1.9.3.2.2current
raisecomOpticalMIBPMGroup
OBJECT-GROUP
A collection of objects that provide optical performance monitoring data for 15 minute and 24 hour intervals.
1.3.6.1.4.1.8886.1.9.3.2.3current
raisecomOpticalMIBNotifyEnableGroup
OBJECT-GROUP
An object to control the generation of notifications.
1.3.6.1.4.1.8886.1.9.3.2.4current
raisecomOpticalMIBNotifGroup
NOTIFICATION-GROUP
A notification generated when a threshold on an optical parameter is exceeded or cleared.
1.3.6.1.4.1.8886.1.9.3.2.5current