PowerNet-MIB
- Registered at
- 1.3.6.1.4.1.318
- Namespace
- apc
- Source file
PowerNet-MIB- Digest
sha256:ffacfa38ca27398ba4a94e9cfa28bcbf6c126dd806c0630149213f99d7f865dd
Imports
| From | Symbols |
|---|---|
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
PowerNet-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AirIRG2RDType2IOState type | ||||
| AirIRSCCapacityControlType type | ||||
| AirIRSCConfigType type | ||||
| AirIRSCFanSpeedControl type | ||||
| AirIRSCFanSpeedPreference type | ||||
| AirIRmActivityState type | ||||
| AirIRmAlarmState type | ||||
| AirIRmControlState type | ||||
| AirIRmStopState type | ||||
| Rpdu2OutletPhaseLayoutType type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| apc OBJECT-IDENTITY | 1.3.6.1.4.1.318 | |||
| products OBJECT-IDENTITY | 1.3.6.1.4.1.318.1 | |||
| hardware OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1 | |||
| ups OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1 | |||
| upsIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.1 | |||
| upsBasicIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.1.1 | |||
| upsBasicIdentModel OBJECT-TYPE The UPS model name (e.g. 'APC Smart-UPS 600'). | 1.3.6.1.4.1.318.1.1.1.1.1.1 | DisplayString | read-only | mandatory |
| upsBasicIdentName OBJECT-TYPE An 8 byte ID string identifying the UPS. This object can be set by the administrator. For GVS, GPX and GVL products, this string can be up to 32 bytes. | 1.3.6.1.4.1.318.1.1.1.1.1.2 | DisplayString | read-write | mandatory |
| upsBasicIdentFamilyName OBJECT-TYPE The UPS model family name for the product. | 1.3.6.1.4.1.318.1.1.1.1.1.3 | DisplayString | read-only | mandatory |
| upsBasicIdentModelType OBJECT-TYPE The detailed model information of the system. | 1.3.6.1.4.1.318.1.1.1.1.1.4 | DisplayString | read-only | mandatory |
| upsAdvIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.1.2 | |||
| upsAdvIdentFirmwareRevision OBJECT-TYPE The firmware revision of the UPS system's microprocessor. | 1.3.6.1.4.1.318.1.1.1.1.2.1 | DisplayString | read-only | mandatory |
| upsAdvIdentDateOfManufacture OBJECT-TYPE The date when the UPS was manufactured in mm/dd/yy (or yyyy) format. | 1.3.6.1.4.1.318.1.1.1.1.2.2 | DisplayString | read-only | mandatory |
| upsAdvIdentSerialNumber OBJECT-TYPE An 8-character string (12-character in case of 3 phase UPS) identifying the serial number of the UPS internal microprocessor. This number is set at the factory. NOTE: This number does NOT correspond to the serial number on the rear of the UPS. | 1.3.6.1.4.1.318.1.1.1.1.2.3 | DisplayString | read-only | mandatory |
| upsAdvIdentFirmwareRevision2 OBJECT-TYPE The firmware revision of a UPS system co-microprocessor. | 1.3.6.1.4.1.318.1.1.1.1.2.4 | DisplayString | read-only | mandatory |
| upsAdvIdentSkuNumber OBJECT-TYPE The SKU number of a UPS system. | 1.3.6.1.4.1.318.1.1.1.1.2.5 | DisplayString | read-only | mandatory |
| upsAdvIdentHardwareRevision OBJECT-TYPE The hardware revision of a UPS system. | 1.3.6.1.4.1.318.1.1.1.1.2.6 | DisplayString | read-only | mandatory |
| upsAdvIdentUpsPhaseConfigType OBJECT-TYPE The type definition, based on phase configuration. 1 - Unknown 2 - 3 phase in/out 3 - 1 phase in/out 4 - 3 phase in/1 phase out | 1.3.6.1.4.1.318.1.1.1.1.2.7 | INTEGER {unknown(1), threePhaseInOut(2), onePhaseInOut(3), threePhaseInOneOut(4)} | read-only | mandatory |
| upsAdvEnergyStorageType OBJECT-TYPE The energy storage type connected to the UPS. It states battery type and battery chemistry. 1 - Unknown 2 - VRLA or wet cells 3 - NiCd batteries 4 - Lithium-ion batteries 5 - No energy storage 6 - Flywheel 7 - Ultracaps | 1.3.6.1.4.1.318.1.1.1.1.2.8 | INTEGER {unknown(1), vrlaOrWetCells(2), niCdBatteries(3), liIonBatteries(4), noEnergyStorage(5), flywheel(6), ultracaps(7)} | read-only | mandatory |
| upsBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.2 | |||
| upsBasicBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.2.1 | |||
| upsBasicBatteryStatus OBJECT-TYPE The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime. A batteryInFaultCondition(4)value indicates that a battery installed has an internal error condition. | 1.3.6.1.4.1.318.1.1.1.2.1.1 | INTEGER {unknown(1), batteryNormal(2), batteryLow(3), batteryInFaultCondition(4)} | read-only | mandatory |
| upsBasicBatteryTimeOnBattery OBJECT-TYPE The elapsed time since the UPS has switched to battery power. | 1.3.6.1.4.1.318.1.1.1.2.1.2 | TimeTicks | read-only | mandatory |
| upsBasicBatteryLastReplaceDate OBJECT-TYPE The date when the UPS system's batteries were last replaced in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator. For Symmetra PX 250/500 this OID is read only and is configurable in the local display only. | 1.3.6.1.4.1.318.1.1.1.2.1.3 | DisplayString | read-write | mandatory |
| upsAdvBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.2.2 | |||
| upsAdvBatteryCapacity OBJECT-TYPE The remaining battery capacity expressed in percent of full capacity. | 1.3.6.1.4.1.318.1.1.1.2.2.1 | Gauge | read-only | mandatory |
| upsAdvBatteryTemperature OBJECT-TYPE The current internal UPS temperature expressed in Celsius. Temperatures below zero read as 0. Consider using upsHighPrecExtdBatteryTemperature instead. | 1.3.6.1.4.1.318.1.1.1.2.2.2 | Gauge | read-only | mandatory |
| upsAdvBatteryRunTimeRemaining OBJECT-TYPE The UPS battery run time remaining before battery exhaustion. | 1.3.6.1.4.1.318.1.1.1.2.2.3 | TimeTicks | read-only | mandatory |
| upsAdvBatteryReplaceIndicator OBJECT-TYPE Indicates whether the UPS batteries need replacing. | 1.3.6.1.4.1.318.1.1.1.2.2.4 | INTEGER {noBatteryNeedsReplacing(1), batteryNeedsReplacing(2)} | read-only | mandatory |
| upsAdvBatteryNumOfBattPacks OBJECT-TYPE The number of external battery packs connected to the UPS. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME. | 1.3.6.1.4.1.318.1.1.1.2.2.5 | INTEGER | read-only | mandatory |
| upsAdvBatteryNumOfBadBattPacks OBJECT-TYPE The number of external battery packs connected to the UPS that are defective. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME. | 1.3.6.1.4.1.318.1.1.1.2.2.6 | INTEGER | read-only | mandatory |
| upsAdvBatteryNominalVoltage OBJECT-TYPE The nominal battery voltage in Volts. | 1.3.6.1.4.1.318.1.1.1.2.2.7 | INTEGER | read-only | mandatory |
| upsAdvBatteryActualVoltage OBJECT-TYPE The actual battery bus voltage in Volts. | 1.3.6.1.4.1.318.1.1.1.2.2.8 | INTEGER | read-only | mandatory |
| upsAdvBatteryCurrent OBJECT-TYPE The battery current in Amps. | 1.3.6.1.4.1.318.1.1.1.2.2.9 | INTEGER | read-only | mandatory |
| upsAdvTotalDCCurrent OBJECT-TYPE The total DC current in Amps. | 1.3.6.1.4.1.318.1.1.1.2.2.10 | INTEGER | read-only | mandatory |
| upsAdvBatteryFullCapacity OBJECT-TYPE The full chargeable capacity of the battery which is expressed in percentage. | 1.3.6.1.4.1.318.1.1.1.2.2.11 | INTEGER | read-only | mandatory |
| upsAdvBatteryActualVoltageTable OBJECT-TYPE A list of battery table entries. The number of battery frames present in UPS. | 1.3.6.1.4.1.318.1.1.1.2.2.12 | not-accessible | mandatory | |
| upsAdvBatteryActualVoltageEntry OBJECT-TYPE Information applicable to each of the Battery frames. | 1.3.6.1.4.1.318.1.1.1.2.2.12.1 | not-accessible | mandatory | |
| upsAdvBatteryActualVoltageTableIndex OBJECT-TYPE The Battery Frame identifier. Battery Frame index. | 1.3.6.1.4.1.318.1.1.1.2.2.12.1.1 | INTEGER | read-only | mandatory |
| upsAdvBatteryActualVoltagePolarity OBJECT-TYPE The selected Battery Voltage Polarity. 0 indicates positive polarity. 1 indicates negative polarity. | 1.3.6.1.4.1.318.1.1.1.2.2.12.1.2 | INTEGER {positive(0), negative(1)} | read-only | mandatory |
| upsAdvBatteryFrameActualVoltage OBJECT-TYPE The actual battery bus voltage in Volts. | 1.3.6.1.4.1.318.1.1.1.2.2.12.1.3 | INTEGER | read-only | mandatory |
| upsAdvTotalDCCurrentTable OBJECT-TYPE A list of Battery Frame table entries. The number of entries is given by the value of Number of Battery Frames. | 1.3.6.1.4.1.318.1.1.1.2.2.13 | not-accessible | mandatory | |
| upsAdvTotalDCCurrentEntry OBJECT-TYPE An entry containing information applicable to a particular Battery Frame. | 1.3.6.1.4.1.318.1.1.1.2.2.13.1 | not-accessible | mandatory | |
| upsAdvTotalDCCurrentTableIndex OBJECT-TYPE The Battery Frame identifier. Total DC Current Table Index. | 1.3.6.1.4.1.318.1.1.1.2.2.13.1.1 | INTEGER | read-only | mandatory |
| upsAdvTotalDCCurrentPolarity OBJECT-TYPE The selected Battery Current Polarity. 0 indicates positive polarity. 1 indicates negative polarity. | 1.3.6.1.4.1.318.1.1.1.2.2.13.1.2 | INTEGER {positive(0), negative(1)} | read-only | mandatory |
| upsAdvTotalFrameDCCurrent OBJECT-TYPE The Total DC Current of battery in Amperes. | 1.3.6.1.4.1.318.1.1.1.2.2.13.1.3 | INTEGER | read-only | mandatory |
| upsAdvBatteryCurrentTable OBJECT-TYPE A list of Battery Frame table entries. The number of entries is given by number of Battery frames present. | 1.3.6.1.4.1.318.1.1.1.2.2.14 | not-accessible | mandatory | |
| upsAdvBatteryCurrentEntry OBJECT-TYPE An entry containing information applicable to a particular battery frame. | 1.3.6.1.4.1.318.1.1.1.2.2.14.1 | not-accessible | mandatory | |
| upsAdvBatteryCurrentTableIndex OBJECT-TYPE The Battery Frame identifier. Battery Current Table Index. | 1.3.6.1.4.1.318.1.1.1.2.2.14.1.1 | INTEGER | read-only | mandatory |
| upsAdvBatteryCurrentIndex OBJECT-TYPE The battery frame identifier. | 1.3.6.1.4.1.318.1.1.1.2.2.14.1.2 | INTEGER | read-only | mandatory |
| upsAdvBatteryCurrentPolarity OBJECT-TYPE The selected Battery current polarity. 0 indicates positive polarity. 1 indicates negative polarity | 1.3.6.1.4.1.318.1.1.1.2.2.14.1.3 | INTEGER {positive(0), negative(1)} | read-only | mandatory |
| upsAdvBatteryFrameCurrent OBJECT-TYPE The Battery current measured in Amperes | 1.3.6.1.4.1.318.1.1.1.2.2.14.1.4 | INTEGER | read-only | mandatory |
| upsAdvBatteryEstimatedChargeTime OBJECT-TYPE The estimated remaining time required to charge the UPS to a full state of charge. | 1.3.6.1.4.1.318.1.1.1.2.2.15 | TimeTicks | read-only | mandatory |
| upsAdvBatteryPower OBJECT-TYPE The measured battery power in kW. | 1.3.6.1.4.1.318.1.1.1.2.2.16 | INTEGER | read-only | mandatory |
| upsAdvBatteryChargerStatus OBJECT-TYPE The status of the battery charger. If the UPS is unable to find the state of charger, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.2.2.17 | INTEGER {unknown(1), ok(2), inFaultCondition(3), floatCharging(4), boostCharging(5), resting(6), notCharging(7), equalizationCharging(8), testInProgress(9), cyclicFloatCharging(10)} | read-only | mandatory |
| upsAdvBatteryInternalSKU OBJECT-TYPE The SKU of the internal battery. | 1.3.6.1.4.1.318.1.1.1.2.2.19 | DisplayString | read-only | mandatory |
| upsAdvBatteryExternalSKU OBJECT-TYPE The SKU of the external battery. | 1.3.6.1.4.1.318.1.1.1.2.2.20 | DisplayString | read-only | mandatory |
| upsAdvBatteryRecommendedReplaceDate OBJECT-TYPE The recommended replacement date for the battery based on the UPS internal battery life algorithm. | 1.3.6.1.4.1.318.1.1.1.2.2.21 | DisplayString | read-only | mandatory |
| upsAdvBatteryNominalBackupTime OBJECT-TYPE Defines the runtime of the user supplied battery in minutes, when battery is new. | 1.3.6.1.4.1.318.1.1.1.2.2.22 | INTEGER | read-only | mandatory |
| upsAdvBatteryCondition OBJECT-TYPE Health of the battries based on the battery test. | 1.3.6.1.4.1.318.1.1.1.2.2.23 | INTEGER {unknown(1), ok(2), weak(3), poor(4)} | read-only | mandatory |
| upsAdvBatteryChargingCurrentRestricted OBJECT-TYPE Indicates whether battery charging current is restricted or not. The value of yes(1) indicates that battery charging current is restricted . The value of no(2) indicates that battery charging current is not restricted. | 1.3.6.1.4.1.318.1.1.1.2.2.24 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| upsAdvBatteryTotalCapacity OBJECT-TYPE The actual available battery capacity of the system expressed in ampere hours (Ah). The value is updated continuously, for example when battery breakers are opened or closed, or when battery strings/battery blocks are added or removed. | 1.3.6.1.4.1.318.1.1.1.2.2.25 | Gauge | read-only | mandatory |
| upsAdvBatteryFuseStatus OBJECT-TYPE If battery system has one common fuse for the battery system, the status is given by this value. 1 = Fuse Open 2 = Fuse Ok 3 = Not present | 1.3.6.1.4.1.318.1.1.1.2.2.26 | INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)} | read-only | mandatory |
| upsAdvBatteryBreakerStatus OBJECT-TYPE The value indicates the aggregated status of the battery breakers in the system. disconnected(1) indicates none of the battery breakers are closed, and the battery system is disconnected closed(2) indicates at least one of the battery breakers in the system is closed notPresent(3) if not present | 1.3.6.1.4.1.318.1.1.1.2.2.27 | INTEGER {disconnected(1), closed(2), notPresent(3)} | read-only | mandatory |
| upsAdvBatteryWiringConfiguration OBJECT-TYPE The value indicates the wiring configuration, whether the battery is 2-wire or 3-wire. If it's a 3-wire battery system, the system can have 2 voltages and currents per cabinet. 1 = 2-wire (a non-split battery) 2 = 3-wire (a split battery) | 1.3.6.1.4.1.318.1.1.1.2.2.28 | INTEGER {twoWire(1), threeWire(2)} | read-only | mandatory |
| upsHighPrecBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.2.3 | |||
| upsHighPrecBatteryCapacity OBJECT-TYPE The remaining battery capacity expressed in tenths of percent of full capacity. | 1.3.6.1.4.1.318.1.1.1.2.3.1 | Gauge | read-only | mandatory |
| upsHighPrecBatteryTemperature OBJECT-TYPE The current internal UPS temperature expressed in tenths of degrees Celsius. Temperatures below zero read as 0. Consider using upsHighPrecExtdBatteryTemperature instead. | 1.3.6.1.4.1.318.1.1.1.2.3.2 | Gauge | read-only | mandatory |
| upsHighPrecBatteryNominalVoltage OBJECT-TYPE The nominal battery voltage in tenths of Volts. | 1.3.6.1.4.1.318.1.1.1.2.3.3 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryActualVoltage OBJECT-TYPE The actual battery bus voltage in tenths of Volts. | 1.3.6.1.4.1.318.1.1.1.2.3.4 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryCurrent OBJECT-TYPE The battery current in tenths of Amps. | 1.3.6.1.4.1.318.1.1.1.2.3.5 | INTEGER | read-only | mandatory |
| upsHighPrecTotalDCCurrent OBJECT-TYPE The total DC current in tenths of Amps. | 1.3.6.1.4.1.318.1.1.1.2.3.6 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryActualVoltageTable OBJECT-TYPE A list of Battery frame table entries. The number of entries is given by the number of Battery frames. | 1.3.6.1.4.1.318.1.1.1.2.3.7 | not-accessible | mandatory | |
| upsHighPrecBatteryActualVoltageEntry OBJECT-TYPE An entry containing information applicable to a particular battery frame. | 1.3.6.1.4.1.318.1.1.1.2.3.7.1 | not-accessible | mandatory | |
| upsHighPrecBatteryActualVoltageTableIndex OBJECT-TYPE The Battery Frame identifier. High Precision Actual Voltage Table Index. | 1.3.6.1.4.1.318.1.1.1.2.3.7.1.1 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryActualVoltagePolarity OBJECT-TYPE The selected Battery Voltage polarity. 0 indicates positive polarity. 1 indicates negative polarity. | 1.3.6.1.4.1.318.1.1.1.2.3.7.1.2 | INTEGER {positive(0), negative(1)} | read-only | mandatory |
| upsHighPrecBatteryVoltage OBJECT-TYPE The actual battery bus voltage expressed as tenths of Volts. | 1.3.6.1.4.1.318.1.1.1.2.3.7.1.3 | INTEGER | read-only | mandatory |
| upsHighPrecTotalDCCurrentTable OBJECT-TYPE A list of Battery Frame table entries. The number of entries is given by the number of battery frames. | 1.3.6.1.4.1.318.1.1.1.2.3.8 | not-accessible | mandatory | |
| upsHighPrecTotalDCCurrentEntry OBJECT-TYPE An entry containing information applicable to a particular battery frame. | 1.3.6.1.4.1.318.1.1.1.2.3.8.1 | not-accessible | mandatory | |
| upsHighPrecTotalDCCurrentTableIndex OBJECT-TYPE The Battery Frame identifier. High precision Total DC Current index. | 1.3.6.1.4.1.318.1.1.1.2.3.8.1.1 | INTEGER | read-only | mandatory |
| upsHighPrecTotalDCCurrentPolarity OBJECT-TYPE The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity. | 1.3.6.1.4.1.318.1.1.1.2.3.8.1.2 | INTEGER {positive(0), negative(1)} | read-only | mandatory |
| upsHighPrecTotalDCFrameCurrent OBJECT-TYPE The total DC current in tenths of Amperes. | 1.3.6.1.4.1.318.1.1.1.2.3.8.1.3 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryCurrentTable OBJECT-TYPE A list of Battery Frame table entries. The number of entries is given by the number of battery frames. | 1.3.6.1.4.1.318.1.1.1.2.3.9 | not-accessible | mandatory | |
| upsHighPrecBatteryCurrentEntry OBJECT-TYPE An entry containing information applicable to a particular battery frame. | 1.3.6.1.4.1.318.1.1.1.2.3.9.1 | not-accessible | mandatory | |
| upsHighPrecBatteryCurrentTableIndex OBJECT-TYPE The Battery frame identifier. Battery Frame index. | 1.3.6.1.4.1.318.1.1.1.2.3.9.1.1 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryCurrentIndex OBJECT-TYPE The Battery frame identifier. Battery Index for each frame. | 1.3.6.1.4.1.318.1.1.1.2.3.9.1.2 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryCurrentPolarity OBJECT-TYPE The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity. | 1.3.6.1.4.1.318.1.1.1.2.3.9.1.3 | INTEGER {positive(0), negative(1)} | read-only | mandatory |
| upsHighPrecBatteryFrameCurrent OBJECT-TYPE The Battery current in tenths of Amperes. | 1.3.6.1.4.1.318.1.1.1.2.3.9.1.4 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPacks OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.2.3.10 | |||
| upsHighPrecBatteryPackTableSize OBJECT-TYPE The number of entries in the upsHighPrecBatteryPacks. | 1.3.6.1.4.1.318.1.1.1.2.3.10.1 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPackTable OBJECT-TYPE A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2 | not-accessible | mandatory | |
| upsHighPrecBatteryPackEntry OBJECT-TYPE An entry containing information applicable to a particular battery pack. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1 | not-accessible | mandatory | |
| upsHighPrecBatteryPackIndex OBJECT-TYPE The battery pack identifier. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryCartridgeIndex OBJECT-TYPE The battery cartridge identifier. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPackFirmwareRevision OBJECT-TYPE The battery pack firmware revision. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.3 | DisplayString | read-only | mandatory |
| upsHighPrecBatteryPackSerialNumber OBJECT-TYPE The battery pack serial number. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4 | DisplayString | read-only | mandatory |
| upsHighPrecBatteryPackTemperature OBJECT-TYPE The battery pack temperature measured in 10ths of degree Celcius | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPackStatus OBJECT-TYPE The battery status for the pack only. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 GeneralError bit 9 Communication bit 10 DisconnectedFrame bit 11 FirmwareMismatch | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.6 | OCTET STRING | read-only | mandatory |
| upsHighPrecBatteryPackCartridgeHealth OBJECT-TYPE The battery cartridge health. bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement cartridge bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order replacement cartridge bit 4 Battery lifetime exceeded acknowledged, replace battery bit 5 Battery measured lifetime near end, order replacement cartridge bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7 | OCTET STRING | read-only | mandatory |
| upsHighPrecBatteryPackCartridgeReplaceDate OBJECT-TYPE The battery cartridge estimated battery replace date. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8 | DisplayString | read-only | mandatory |
| upsHighPrecBatteryPackCartridgeInstallDate OBJECT-TYPE The battery cartridge install date. | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.9 | DisplayString | read-write | mandatory |
| upsHighPrecBatteryPackCartridgeStatus OBJECT-TYPE The battery cartridge status. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 GeneralError bit 9 Communication bit 10 DisconnectedFrame bit 11 FirmwareMismatch | 1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10 | OCTET STRING | read-only | mandatory |
| upsHighPrecBatteryPackOnlyTableSize OBJECT-TYPE The number of entries in the upsHighPrecBatteryPacks. | 1.3.6.1.4.1.318.1.1.1.2.3.10.3 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPackOnlyTable OBJECT-TYPE A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4 | not-accessible | mandatory | |
| upsHighPrecBatteryPackOnlyEntry OBJECT-TYPE An entry containing information applicable to a particular battery pack. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1 | not-accessible | mandatory | |
| upsHighPrecBatteryPackOnlyIndex OBJECT-TYPE The battery pack identifier. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.1 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPackOnlyFirmwareRevision OBJECT-TYPE The battery pack firmware revision. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.2 | DisplayString | read-only | mandatory |
| upsHighPrecBatteryPackOnlySerialNumber OBJECT-TYPE The battery pack serial number. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.3 | DisplayString | read-only | mandatory |
| upsHighPrecBatteryPackOnlyTemperature OBJECT-TYPE The battery pack temperature measured in 10ths of degree Celcius | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.4 | INTEGER | read-only | mandatory |
| upsHighPrecBatteryPackOnlyStatus OBJECT-TYPE The battery status for the pack only. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 GeneralError bit 9 Communication bit 10 DisconnectedFrame bit 11 FirmwareMismatch | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.5 | OCTET STRING | read-only | mandatory |
| upsHighPrecBatteryPackOnlyHealth OBJECT-TYPE The battery pack health. bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement pack bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order replacement pack bit 4 Battery lifetime exceeded acknowledged, replace battery bit 5 Battery measured lifetime near end, order replacement pack bit 6 Battery measured lifetime near end acknowledged, order replacement pack | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.6 | OCTET STRING | read-only | mandatory |
| upsHighPrecBatteryPackOnlyReplaceDate OBJECT-TYPE The battery pack estimated battery replace date. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.7 | DisplayString | read-only | mandatory |
| upsHighPrecBatteryPackOnlyInstallDate OBJECT-TYPE The battery pack install date. | 1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.8 | DisplayString | read-write | mandatory |
| upsHighPrecBatteryHealth OBJECT-TYPE The battery health. Bit 0 Battery life okay Bit 1 Battery life near end, order battery cartridge Bit 2 Battery life exceeded, replace battery cartridge Bit 3 Battery life near end acknowledged, order battery cartridge Bit 4 Battery life exceeded acknowledged, replace battery cartridge Bit 5 Battery measured life near end, order battery cartridge Bit 6 Battery measured life near end acknowledged, order battery cartridge | 1.3.6.1.4.1.318.1.1.1.2.3.11 | OCTET STRING | read-only | mandatory |
| upsHighPrecActivePower OBJECT-TYPE Active Power of Battery in tenths of kW | 1.3.6.1.4.1.318.1.1.1.2.3.12 | INTEGER | read-only | mandatory |
| upsHighPrecExtdBatteryTemperature OBJECT-TYPE The current internal UPS temperature expressed in tenths of degrees Celsius. Can be negative. | 1.3.6.1.4.1.318.1.1.1.2.3.13 | INTEGER | read-only | mandatory |
| upsBatteryNumberOfCabinets OBJECT-TYPE The value indicates the number of battery cabinets in total, internal and external. If the UPS only has internal batteries, that number should be 1. If the UPS has external and internal, the number is 1 + number of external cabinets. | 1.3.6.1.4.1.318.1.1.1.2.4 | INTEGER | read-only | mandatory |
| upsBatteryCabinetTable OBJECT-TYPE Table of battery cabinets | 1.3.6.1.4.1.318.1.1.1.2.5 | not-accessible | optional | |
| upsBatteryCabinetEntry OBJECT-TYPE An entry containing information applicable to a particular battery cabinet. | 1.3.6.1.4.1.318.1.1.1.2.5.1 | not-accessible | optional | |
| upsBatteryCabinetIndex OBJECT-TYPE The Battery Cabinet identifier. Battery Cabinet Table Index. | 1.3.6.1.4.1.318.1.1.1.2.5.1.1 | INTEGER | read-only | optional |
| upsBatteryCabinetLocalIndex OBJECT-TYPE The identification number for the actual battery cabinet in the system. 0 corresponds to the internal batteries 1 and higher corresponds to external battery cabinets | 1.3.6.1.4.1.318.1.1.1.2.5.1.2 | INTEGER | read-only | optional |
| upsBatteryCabinetWiringConfiguration OBJECT-TYPE The value indicates the wiring configuration, whether the battery is 2-wire or 3-wire. If it's a 3-wire battery system, the system can have two voltages and currents per cabinet. 1 = 2-wire (a non-split battery) 2 = 3-wire (a split battery) | 1.3.6.1.4.1.318.1.1.1.2.5.1.3 | INTEGER {twoWire(1), threeWire(2)} | read-only | optional |
| upsBatteryCabinetVoltagePolarity1 OBJECT-TYPE The battery voltage. For a non-split battery, it is the full voltage. For a split battery, the value is the voltage for one side/half of the battery | 1.3.6.1.4.1.318.1.1.1.2.5.1.4 | INTEGER | read-only | optional |
| upsBatteryCabinetVoltagePolarity2 OBJECT-TYPE The voltage for the second side/half of the battery in a split battery system. If it is not a split battery, this reports -1 | 1.3.6.1.4.1.318.1.1.1.2.5.1.5 | INTEGER | read-only | optional |
| upsBatteryCabinetCurrentPolarity1 OBJECT-TYPE The battery current. For a non-split battery, it is the full current. For a split battery, the value is the current for one side/half of the battery | 1.3.6.1.4.1.318.1.1.1.2.5.1.6 | INTEGER | read-only | optional |
| upsBatteryCabinetCurrentPolarity2 OBJECT-TYPE The current for the second side/half of the battery in a split battery system. If it is not a split battery, this reports -1 | 1.3.6.1.4.1.318.1.1.1.2.5.1.7 | INTEGER | read-only | optional |
| upsBatteryCabinetTemperature OBJECT-TYPE The measured temperature of the battery cabinet in tenths of degrees Celcius | 1.3.6.1.4.1.318.1.1.1.2.5.1.8 | INTEGER | read-only | optional |
| upsBatteryCabinetMaxTemperature OBJECT-TYPE The highest temperature measured for the battery in the battery cabinet in tenths of degrees Celcius. If there are multiple sensors in the battery cabinet, it is the selected highest actual value of measured temperatures. If there is battery string information, it is the highest actual battery string temperature value. | 1.3.6.1.4.1.318.1.1.1.2.5.1.9 | INTEGER | read-only | optional |
| upsBatteryCabinetMinTemperature OBJECT-TYPE The lowest temperature measured for the battery in the battery cabinet in tenths of degrees Celcius. If there are multiple sensors in the battery cabinet, it is the selected lowest actual value of measured temperatures. If there is string information, it is the lowest actual battery string temperature value. | 1.3.6.1.4.1.318.1.1.1.2.5.1.10 | INTEGER | read-only | optional |
| upsBatteryCabinetAverageTemperature OBJECT-TYPE The average temperature for all the battery sensors in the battery cabinet and for the battery strings, if battery strings are present. Measured in tenths of degrees Celcius. | 1.3.6.1.4.1.318.1.1.1.2.5.1.11 | INTEGER | read-only | optional |
| upsBatteryCabinetFuse OBJECT-TYPE If the battery cabinet has a common fuse, the status is given by this value. 1 = Fuse open 2 = Fuse OK 3 = Not present | 1.3.6.1.4.1.318.1.1.1.2.5.1.12 | INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)} | read-only | optional |
| upsBatteryCabinetBreaker OBJECT-TYPE The value indicates the battery cabinet breaker status. Reports 1 if no breaker is present. 1 = No breaker 2 = Unknown 3 = Breaker open 4 = Breaker closed | 1.3.6.1.4.1.318.1.1.1.2.5.1.13 | INTEGER {noBreaker(1), unknown(2), breakerOpen(3), breakerClosed(4)} | read-only | optional |
| upsBatteryCabinetNumberOfStrings OBJECT-TYPE The number of battery strings in the battery cabinet. The value can be 0, meaning that no additional information on the battery string is available. 1 and higher means data in the table is provided. | 1.3.6.1.4.1.318.1.1.1.2.5.1.14 | INTEGER | read-only | optional |
| upsBatteryCabinetNumberOfVerticalPositions OBJECT-TYPE The number of vertical levels or shelves for battery blocks/modules. The levels are indexed from the bottom up | 1.3.6.1.4.1.318.1.1.1.2.5.1.15 | INTEGER | read-only | optional |
| upsBatteryCabinetNumberOfHorizontalPositions OBJECT-TYPE The number of horizontal positions for battery blocks/modules. The levels are indexed from left to right | 1.3.6.1.4.1.318.1.1.1.2.5.1.16 | INTEGER | read-only | optional |
| upsBatteryCabStringTable OBJECT-TYPE Table of battery strings in the complete battery solution | 1.3.6.1.4.1.318.1.1.1.2.6 | not-accessible | optional | |
| upsBatteryCabStringEntry OBJECT-TYPE An entry containing information applicable to a particular battery string in the battery cabinet. | 1.3.6.1.4.1.318.1.1.1.2.6.1 | not-accessible | optional | |
| upsBatteryCabStringIndex OBJECT-TYPE The battery cabinet string identifier. Battery cabinet string or halfstring table index. | 1.3.6.1.4.1.318.1.1.1.2.6.1.1 | INTEGER | read-only | optional |
| upsBatteryCabStringCabReference OBJECT-TYPE Reference to the global battery cabinet index where the battery string is placed. | 1.3.6.1.4.1.318.1.1.1.2.6.1.2 | INTEGER | read-only | optional |
| upsBatteryCabStringLocalIndex OBJECT-TYPE Local battery string identification index in the actual battery cabinet (E.g. String 2 in cabinet) | 1.3.6.1.4.1.318.1.1.1.2.6.1.3 | INTEGER | read-only | optional |
| upsBatteryCabStringCurrent OBJECT-TYPE The current in a battery string or battery halfstring, in tenths of Amps. | 1.3.6.1.4.1.318.1.1.1.2.6.1.4 | INTEGER | read-only | optional |
| upsBatteryCabStringAverageTemperature OBJECT-TYPE Temperature of the battery string or the average of the aggregated temperature of each battery block/module (in tenths of degrees Celcius). | 1.3.6.1.4.1.318.1.1.1.2.6.1.5 | INTEGER | read-only | optional |
| upsBatteryCabStringMaxTemperature OBJECT-TYPE The actual highest battery temperature measurement for the battery blocks/modules (in tenths of degrees Celcius). | 1.3.6.1.4.1.318.1.1.1.2.6.1.6 | INTEGER | read-only | optional |
| upsBatteryCabStringMinTemperature OBJECT-TYPE The actual lowest battery temperature measurement for the battery blocks/modules (in tenths of degrees Celcius). | 1.3.6.1.4.1.318.1.1.1.2.6.1.7 | INTEGER | read-only | optional |
| upsBatteryCabStringFuseStatus OBJECT-TYPE If the battery string has a common fuse, the status is given by this value. 1 = Fuse open 2 = Fuse OK 3 = Not present | 1.3.6.1.4.1.318.1.1.1.2.6.1.8 | INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)} | read-only | optional |
| upsBatteryCabStringNumberOfBlocks OBJECT-TYPE The number of battery blocks/modules in a battery string. Can be 0, if no data is available in the table of individual battery blocks/cartridges | 1.3.6.1.4.1.318.1.1.1.2.6.1.9 | INTEGER | read-only | optional |
| upsBatteryCabBlockTable OBJECT-TYPE Table of battery blocks/modules in the complete battery solution. | 1.3.6.1.4.1.318.1.1.1.2.7 | not-accessible | optional | |
| upsBatteryCabBlockEntry OBJECT-TYPE An entry containing information applicable to a particular battery block in the battery cabinet. | 1.3.6.1.4.1.318.1.1.1.2.7.1 | not-accessible | optional | |
| upsBatteryCabBlockIndex OBJECT-TYPE The battery cabinet block identifier. Global battery cabinet block table index. | 1.3.6.1.4.1.318.1.1.1.2.7.1.1 | INTEGER | read-only | optional |
| upsBatteryCabBlockStringReference OBJECT-TYPE Reference to the specific global battery string index | 1.3.6.1.4.1.318.1.1.1.2.7.1.2 | INTEGER | read-only | optional |
| upsBatteryCabBlockLocalIndex OBJECT-TYPE Local battery block/module identification index in the actual battery string (E.g. Battery block 3 in the battery string) | 1.3.6.1.4.1.318.1.1.1.2.7.1.3 | INTEGER | read-only | optional |
| upsBatteryCabBlockPresent OBJECT-TYPE Value indicates if battery block/module is present in the system. Typically battery modules are removable and battery blocks are static. Reports notAvailable(3) if data is not available | 1.3.6.1.4.1.318.1.1.1.2.7.1.4 | INTEGER {present(1), notPresent(2), notAvailable(3)} | read-only | optional |
| upsBatteryCabBlockType OBJECT-TYPE Text string value, showing the vendor and model of the battery in the battery block/module | 1.3.6.1.4.1.318.1.1.1.2.7.1.5 | DisplayString | read-only | optional |
| upsBatteryCabBlockTemperature OBJECT-TYPE The temperature for the battery block/module in tenths of degrees Celcius. If multiple sensors are available it is the highest temperature in the battery block/module | 1.3.6.1.4.1.318.1.1.1.2.7.1.6 | INTEGER | read-only | optional |
| upsBatteryCabBlockFuseStatus OBJECT-TYPE If the battery module has a fuse, the status is given by this value. 1 = Fuse open 2 = Fuse OK 3 = Not present | 1.3.6.1.4.1.318.1.1.1.2.7.1.7 | INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)} | read-only | optional |
| upsBatteryCabBlockVoltage OBJECT-TYPE The voltage of the battery block/module | 1.3.6.1.4.1.318.1.1.1.2.7.1.8 | INTEGER | read-only | optional |
| upsBatteryCabBlockNumberOfCells OBJECT-TYPE The number of cells in the battery block/module | 1.3.6.1.4.1.318.1.1.1.2.7.1.9 | INTEGER | read-only | optional |
| upsBatteryCabBlockVerticalPosition OBJECT-TYPE The vertical position of the battery block/module in the actual battery cabinet (E.g. 4, if it is the 4th shelf counting from the bottom) | 1.3.6.1.4.1.318.1.1.1.2.7.1.10 | INTEGER | read-only | optional |
| upsBatteryCabBlockHorizontalPosition OBJECT-TYPE The horizontal position of the battery block/module in the actual battery cabinet (E.g. 3, if it is the 3rd position counting from the left) | 1.3.6.1.4.1.318.1.1.1.2.7.1.11 | INTEGER | read-only | optional |
| upsBatteryCabBlockCellTable OBJECT-TYPE Table of battery cells in a battery block/module in the complete battery solution | 1.3.6.1.4.1.318.1.1.1.2.8 | not-accessible | optional | |
| upsBatteryCabBlockCellEntry OBJECT-TYPE An entry containing information applicable to a particular battery cell inside the battery block. | 1.3.6.1.4.1.318.1.1.1.2.8.1 | not-accessible | optional | |
| upsBatteryCabBlockCellIndex OBJECT-TYPE The battery block cell identifier. Global battery block cell table index. | 1.3.6.1.4.1.318.1.1.1.2.8.1.1 | INTEGER | read-only | optional |
| upsBatteryCabBlockCellReference OBJECT-TYPE Reference to the specific global battery block/module index. | 1.3.6.1.4.1.318.1.1.1.2.8.1.2 | INTEGER | read-only | optional |
| upsBatteryCabBlockCellLocalIndex OBJECT-TYPE Local battery block/module identification index in the actual battery block (E.g. battery cell 5 in the battery block) | 1.3.6.1.4.1.318.1.1.1.2.8.1.3 | INTEGER | read-only | optional |
| upsBatteryCabBlockCellVoltage OBJECT-TYPE The measured battery cell voltage | 1.3.6.1.4.1.318.1.1.1.2.8.1.4 | INTEGER | read-only | optional |
| upsBatteryCabBlockCellTemperature OBJECT-TYPE The temperature for the battery cell in tenths of degrees Celcius. If there is not a temperature sensor for each battery cell, then report -1 for those, which are not present. | 1.3.6.1.4.1.318.1.1.1.2.8.1.5 | INTEGER | read-only | optional |
| upsInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.3 | |||
| upsBasicInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.3.1 | |||
| upsBasicInputPhase OBJECT-TYPE The current AC input phase. | 1.3.6.1.4.1.318.1.1.1.3.1.1 | INTEGER | read-only | mandatory |
| upsAdvInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.3.2 | |||
| upsAdvInputLineVoltage OBJECT-TYPE The current utility line voltage in VAC. | 1.3.6.1.4.1.318.1.1.1.3.2.1 | Gauge | read-only | mandatory |
| upsAdvInputMaxLineVoltage OBJECT-TYPE The maximum utility line voltage in VAC over the previous 1 minute period. | 1.3.6.1.4.1.318.1.1.1.3.2.2 | Gauge | read-only | mandatory |
| upsAdvInputMinLineVoltage OBJECT-TYPE The minimum utility line voltage in VAC over the previous 1 minute period. | 1.3.6.1.4.1.318.1.1.1.3.2.3 | Gauge | read-only | mandatory |
| upsAdvInputFrequency OBJECT-TYPE The current input frequency to the UPS system in Hz. | 1.3.6.1.4.1.318.1.1.1.3.2.4 | Gauge | read-only | mandatory |
| upsAdvInputLineFailCause OBJECT-TYPE The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: - noTransfer(1) -- if there is no transfer yet. - highLineVoltage(2) -- if the transfer to battery is caused by an over voltage greater than the high transfer voltage. - brownout(3) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - blackout(4) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. - smallMomentarySag(5) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - deepMomentarySag(6) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to - smallMomentarySpike(7) -- if the line failure is caused by a rate of change of input voltage less than ten volts per cycle. - largeMomentarySpike(8) -- if the line failure is caused by a rate of change of input voltage greater than ten volts per cycle. - selfTest(9) -- if the UPS was commanded to do a self test. - rateOfVoltageChange(10) -- if the failure is due to the rate of change of the line voltage. | 1.3.6.1.4.1.318.1.1.1.3.2.5 | INTEGER {noTransfer(1), highLineVoltage(2), brownout(3), blackout(4), smallMomentarySag(5), deepMomentarySag(6), smallMomentarySpike(7), largeMomentarySpike(8), selfTest(9), rateOfVoltageChange(10)} | read-only | mandatory |
| upsAdvInputNominalFrequency OBJECT-TYPE The nominal input frequency of the UPS system in Hz. | 1.3.6.1.4.1.318.1.1.1.3.2.6 | INTEGER | read-only | mandatory |
| upsAdvInputNominalVoltage OBJECT-TYPE The nominal input voltage of the UPS system in VAC. | 1.3.6.1.4.1.318.1.1.1.3.2.7 | INTEGER | read-only | mandatory |
| upsAdvInputBypassNominalFrequency OBJECT-TYPE The nominal bypass input frequency of the UPS system in Hz. | 1.3.6.1.4.1.318.1.1.1.3.2.8 | INTEGER | read-only | mandatory |
| upsAdvInputBypassNominalVoltage OBJECT-TYPE The nominal bypass input voltage of the UPS system in VAC. | 1.3.6.1.4.1.318.1.1.1.3.2.9 | INTEGER | read-only | mandatory |
| upsAdvInputStatisticsTable OBJECT-TYPE A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs. | 1.3.6.1.4.1.318.1.1.1.3.2.10 | not-accessible | mandatory | |
| upsAdvInputStatisticsEntry OBJECT-TYPE An entry containing information applicable to a particular input. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1 | not-accessible | mandatory | |
| upsAdvInputStatisticsIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.1 | INTEGER | read-only | mandatory |
| upsAdvInputApparentPower OBJECT-TYPE The input apparent power(sum of all of the three phases) measured in kVA. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.2 | INTEGER | read-only | mandatory |
| upsAdvInputVoltageTHD OBJECT-TYPE The input voltage Total Harmonic Distortion in percent. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.3 | INTEGER | read-only | mandatory |
| upsAdvInputBypassVoltageTHD OBJECT-TYPE The bypass input voltage Total Harmonic Distortion in percent. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.4 | INTEGER | read-only | mandatory |
| upsAdvInputPeakCurrent OBJECT-TYPE The input peak current in Amperes. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.5 | INTEGER | read-only | mandatory |
| upsAdvInputBypassPeakCurrent OBJECT-TYPE The bypass input peak current in Amperes. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.6 | INTEGER | read-only | mandatory |
| upsAdvInputActivePower OBJECT-TYPE The input active power measured in kW. | 1.3.6.1.4.1.318.1.1.1.3.2.10.1.7 | INTEGER | read-only | mandatory |
| upsAdvInputTotalApparentPower OBJECT-TYPE The input total apparent power(sum of all three phases) of the UPS system in kVA. | 1.3.6.1.4.1.318.1.1.1.3.2.11 | INTEGER | read-only | mandatory |
| upsAdvInputTotalActivePower OBJECT-TYPE The input total active power(sum of all three phases) of the UPS system in kW. | 1.3.6.1.4.1.318.1.1.1.3.2.12 | INTEGER | read-only | mandatory |
| upsAdvInputBypassTotalApparentPower OBJECT-TYPE The input bypass total apparent power(sum of all three phases) of the UPS system in kVA. | 1.3.6.1.4.1.318.1.1.1.3.2.13 | INTEGER | read-only | mandatory |
| upsAdvInputBypassTotalActivePower OBJECT-TYPE The input bypass total active power(sum of all three phases) of the UPS system in kW. | 1.3.6.1.4.1.318.1.1.1.3.2.14 | INTEGER | read-only | mandatory |
| upsAdvInputEnergyUsage OBJECT-TYPE The input energy usage of the UPS in kWh. | 1.3.6.1.4.1.318.1.1.1.3.2.15 | Unsigned32 | read-only | mandatory |
| upsAdvInputDCVoltage OBJECT-TYPE The DC input voltage in Volts. | 1.3.6.1.4.1.318.1.1.1.3.2.16 | INTEGER | read-only | mandatory |
| upsAdvInputDCCurrent OBJECT-TYPE The DC input current in Amps. | 1.3.6.1.4.1.318.1.1.1.3.2.17 | INTEGER | read-only | mandatory |
| upsHighPrecInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.3.3 | |||
| upsHighPrecInputLineVoltage OBJECT-TYPE The current utility line voltage in tenths of VAC. | 1.3.6.1.4.1.318.1.1.1.3.3.1 | Gauge | read-only | mandatory |
| upsHighPrecInputMaxLineVoltage OBJECT-TYPE The maximum utility line voltage in tenths of VAC over the previous 1 minute period. | 1.3.6.1.4.1.318.1.1.1.3.3.2 | Gauge | read-only | mandatory |
| upsHighPrecInputMinLineVoltage OBJECT-TYPE The minimum utility line voltage in tenths of VAC over the previous 1 minute period. | 1.3.6.1.4.1.318.1.1.1.3.3.3 | Gauge | read-only | mandatory |
| upsHighPrecInputFrequency OBJECT-TYPE The current input frequency to the UPS system in tenths of Hz. | 1.3.6.1.4.1.318.1.1.1.3.3.4 | Gauge | read-only | mandatory |
| upsHighPrecInputEnergyUsage OBJECT-TYPE The input energy usage of the UPS in hundredths of kWh. | 1.3.6.1.4.1.318.1.1.1.3.3.5 | Unsigned32 | read-only | mandatory |
| upsHighPrecInputBypassVoltage OBJECT-TYPE The current bypass line voltage in tenths of VAC. | 1.3.6.1.4.1.318.1.1.1.3.3.6 | Unsigned32 | read-only | mandatory |
| upsHighPrecInputBypassFrequency OBJECT-TYPE The current input bypass frequency to the UPS system in tenths of Hz. | 1.3.6.1.4.1.318.1.1.1.3.3.7 | Unsigned32 | read-only | mandatory |
| upsOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.4 | |||
| upsBasicOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.4.1 | |||
| upsBasicOutputStatus OBJECT-TYPE The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1). During self-test most UPSes report onBattery(3) but some that support it will report onBatteryTest(15). To determine self-test status across all UPSes, refer to the upsBasicStateOutputState OID. | 1.3.6.1.4.1.318.1.1.1.4.1.1 | INTEGER {unknown(1), onLine(2), onBattery(3), onSmartBoost(4), timedSleeping(5), softwareBypass(6), off(7), rebooting(8), switchedBypass(9), hardwareFailureBypass(10), sleepingUntilPowerReturn(11), onSmartTrim(12), ecoMode(13), hotStandby(14), onBatteryTest(15), emergencyStaticBypass(16), staticBypassStandby(17), powerSavingMode(18), spotMode(19), eConversion(20), chargerSpotmode(21), inverterSpotmode(22), activeLoad(23), batteryDischargeSpotmode(24), inverterStandby(25), chargerOnly(26)} | read-only | mandatory |
| upsBasicOutputPhase OBJECT-TYPE The actual number of output phases in a UPS | 1.3.6.1.4.1.318.1.1.1.4.1.2 | INTEGER | read-only | mandatory |
| upsBasicSystemStatus OBJECT-TYPE Current state for the whole system (UPS and surrounding breakers). If the UPS is unable to determine the state of the system, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.4.1.3 | INTEGER {unknown(1), onLine(2), onBattery(3), onSmartBoost(4), timedSleeping(5), softwareBypass(6), off(7), rebooting(8), switchedBypass(9), hardwareFailureBypass(10), sleepingUntilPowerReturn(11), onSmartTrim(12), ecoMode(13), inverter(14), eConversion(15), staticBypassStandby(16), efficiencyBoosterMode(17)} | read-only | mandatory |
| upsBasicSystemInternalTemperature OBJECT-TYPE The actual internal temperature of the UPS system in Celsius. | 1.3.6.1.4.1.318.1.1.1.4.1.4 | INTEGER | read-only | mandatory |
| upsBasicSystemInverterStatus OBJECT-TYPE The current state of the UPS inverter. If the UPS is unable to determine the state of the inverter, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.4.1.5 | INTEGER {unknown(1), ok(2), inFaultCondition(3)} | read-only | mandatory |
| upsBasicSystemPFCStatus OBJECT-TYPE The general status of the power factor correction (AC input stage of the UPS). If the UPS is unable to determine the state of PFC, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.4.1.6 | INTEGER {unknown(1), ok(2), inFaultCondition(3)} | read-only | mandatory |
| upsBasicOutputACwiringConfiguration OBJECT-TYPE Indicates if neutral wire on output side of the UPS is used (load wired line to neutral). If the UPS is unable to determine the state of neutral, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.4.1.7 | INTEGER {unknown(1), noNeutralWiredonSystem(2), neutralUsedforSupplyingLoad(3)} | read-only | mandatory |
| upsAdvOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.4.2 | |||
| upsAdvOutputVoltage OBJECT-TYPE The output voltage of the UPS system in VAC. | 1.3.6.1.4.1.318.1.1.1.4.2.1 | Gauge | read-only | mandatory |
| upsAdvOutputFrequency OBJECT-TYPE The current output frequency of the UPS system in Hz. | 1.3.6.1.4.1.318.1.1.1.4.2.2 | Gauge | read-only | mandatory |
| upsAdvOutputLoad OBJECT-TYPE The current UPS load expressed in percent of rated capacity. | 1.3.6.1.4.1.318.1.1.1.4.2.3 | Gauge | read-only | mandatory |
| upsAdvOutputCurrent OBJECT-TYPE The current in amperes drawn by the load on the UPS. | 1.3.6.1.4.1.318.1.1.1.4.2.4 | Gauge | read-only | mandatory |
| upsAdvOutputRedundancy OBJECT-TYPE The number of power modules which can fail or be removed without causing the UPS to generate a Minimum Redundancy Lost event. | 1.3.6.1.4.1.318.1.1.1.4.2.5 | Gauge | read-only | mandatory |
| upsAdvOutputKVACapacity OBJECT-TYPE The maximum load that this UPS can support. This value is dynamic for scalable 3-phase UPSs where power modules can be added for increased capacity. The value indicates the actual available output capacity. For non-scalable 3-phase UPSs the value is fixed to the UPS rating. | 1.3.6.1.4.1.318.1.1.1.4.2.6 | INTEGER | read-only | mandatory |
| upsAdvOutputNominalFrequency OBJECT-TYPE The nominal output frequency of the UPS system in Hz. | 1.3.6.1.4.1.318.1.1.1.4.2.7 | INTEGER | read-only | mandatory |
| upsAdvOutputActivePower OBJECT-TYPE The total output active power of the UPS system in W. The total active power is the sum of phase 1, phase 2 and phase 3 power. | 1.3.6.1.4.1.318.1.1.1.4.2.8 | INTEGER | read-only | mandatory |
| upsAdvOutputApparentPower OBJECT-TYPE The total output apparent power of all phases of the UPS system in VA. | 1.3.6.1.4.1.318.1.1.1.4.2.9 | INTEGER | read-only | mandatory |
| upsAdvOutputStatisticsTable OBJECT-TYPE A list of input table entries. The number of entries is given by the value of upsPhaseNumOutputs. | 1.3.6.1.4.1.318.1.1.1.4.2.10 | not-accessible | mandatory | |
| upsAdvOutputStatisticsEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.1.4.2.10.1 | not-accessible | mandatory | |
| upsAdvOutputStatisticsIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.1.4.2.10.1.1 | INTEGER | read-only | mandatory |
| upsAdvOutputPeakCurrent OBJECT-TYPE The output peak current in Amperes. | 1.3.6.1.4.1.318.1.1.1.4.2.10.1.2 | INTEGER | read-only | mandatory |
| upsAdvOutputCurrentTHD OBJECT-TYPE The output current Total Harmonic Distortion in percent. | 1.3.6.1.4.1.318.1.1.1.4.2.10.1.3 | INTEGER | read-only | mandatory |
| upsAdvOutputCrestFactor OBJECT-TYPE The output current crest factor expressed in tenths. | 1.3.6.1.4.1.318.1.1.1.4.2.10.1.4 | INTEGER | read-only | mandatory |
| upsAdvOutputNeutralCurrent OBJECT-TYPE The neutral current in amperes. | 1.3.6.1.4.1.318.1.1.1.4.2.11 | INTEGER | read-only | mandatory |
| upsAdvOutputEnergyUsage OBJECT-TYPE The output energy usage of the UPS in kWh. | 1.3.6.1.4.1.318.1.1.1.4.2.12 | Unsigned32 | read-only | mandatory |
| upsAdvOutputSourceSynchronization OBJECT-TYPE Indicates the synchronization source for the inverter output frequency. 1. Main 2. Internal 3. External 4. On AC Bypass. 5. External / On Bypass For other values it is unknown | 1.3.6.1.4.1.318.1.1.1.4.2.13 | INTEGER | read-only | mandatory |
| upsAdvOutputInverterFrequency OBJECT-TYPE Output frequency in Hz measured at the output of inverter. | 1.3.6.1.4.1.318.1.1.1.4.2.14 | Gauge | read-only | mandatory |
| upsHighPrecOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.4.3 | |||
| upsHighPrecOutputVoltage OBJECT-TYPE The output voltage of the UPS system in tenths of VAC. | 1.3.6.1.4.1.318.1.1.1.4.3.1 | Gauge | read-only | mandatory |
| upsHighPrecOutputFrequency OBJECT-TYPE The current output frequency of the UPS system in tenths of Hz. | 1.3.6.1.4.1.318.1.1.1.4.3.2 | Gauge | read-only | mandatory |
| upsHighPrecOutputLoad OBJECT-TYPE The current UPS load expressed in tenths of percent of rated capacity. | 1.3.6.1.4.1.318.1.1.1.4.3.3 | Gauge | read-only | mandatory |
| upsHighPrecOutputCurrent OBJECT-TYPE The current in tenths of amperes drawn by the load on the UPS. | 1.3.6.1.4.1.318.1.1.1.4.3.4 | Gauge | read-only | mandatory |
| upsHighPrecOutputEfficiency OBJECT-TYPE The positive values represent efficiency of the UPS in tenths of percent. -1 If UPS supports this OID but the result is not available -2 Load is too low to report efficiency -3 Output off and efficiency is 0 -4 On battery, efficiency is not measured or calculated in this mode -5 In Bypass, efficiency is not measured or calculated in this mode -6 Battery charging, battery is charging and adversely affecting efficiency -7 Poor AC input, the main input is outside the optimum efficiency range | 1.3.6.1.4.1.318.1.1.1.4.3.5 | Integer32 | read-only | mandatory |
| upsHighPrecOutputEnergyUsage OBJECT-TYPE The output energy usage of the UPS in hundredths of kWh. | 1.3.6.1.4.1.318.1.1.1.4.3.6 | Unsigned32 | read-only | mandatory |
| upsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.5 | |||
| upsBasicConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.5.1 | |||
| upsBasicConfigNumDevices OBJECT-TYPE The number of devices that are plugged into the UPS. This value is customer configurable from the device entry table | 1.3.6.1.4.1.318.1.1.1.5.1.1 | INTEGER | read-only | mandatory |
| upsBasicConfigDeviceTable OBJECT-TYPE A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBasicConfigNumDevices. | 1.3.6.1.4.1.318.1.1.1.5.1.2 | not-accessible | mandatory | |
| upsBasicConfigDeviceEntry OBJECT-TYPE The devices plugged in to the UPS. | 1.3.6.1.4.1.318.1.1.1.5.1.2.1 | not-accessible | mandatory | |
| deviceIndex OBJECT-TYPE The index of the device that is plugged into the UPS. | 1.3.6.1.4.1.318.1.1.1.5.1.2.1.1 | INTEGER | read-only | mandatory |
| deviceName OBJECT-TYPE The name/description of the device plugged into the UPS. | 1.3.6.1.4.1.318.1.1.1.5.1.2.1.2 | DisplayString | read-write | mandatory |
| vaRating OBJECT-TYPE The volt-amp rating of the device plugged into the UPS. | 1.3.6.1.4.1.318.1.1.1.5.1.2.1.3 | INTEGER | read-write | mandatory |
| acceptThisDevice OBJECT-TYPE An entry is added if yes, the entry is deleted if no. | 1.3.6.1.4.1.318.1.1.1.5.1.2.1.4 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| upsAdvConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.5.2 | |||
| upsAdvConfigRatedOutputVoltage OBJECT-TYPE The nominal output voltage from the UPS in VAC. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.1 | INTEGER | read-write | mandatory |
| upsAdvConfigHighTransferVolt OBJECT-TYPE The maximum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.2 | INTEGER | read-write | mandatory |
| upsAdvConfigLowTransferVolt OBJECT-TYPE The minimum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.3 | INTEGER | read-write | mandatory |
| upsAdvConfigAlarm OBJECT-TYPE A flag indicating how the UPS should handle audible line fail alarms: timed(1): UPS alarm will sound after a preset timed duration starting from the line fail condition (see OID upsAdvConfigAlarmTimer for the alarm timer value) atLowBattery(2): UPS alarm will sound when the UPS has reached a Low Battery condition during a line fail never(3): Disables the UPS audible alarm mute(4): Mutes the current alarm for some UPSs only when it is in an alarm state and will return to the previously configured option when the UPS recovers from the alarm condition | 1.3.6.1.4.1.318.1.1.1.5.2.4 | INTEGER {timed(1), atLowBattery(2), never(3), mute(4)} | read-write | mandatory |
| upsAdvConfigAlarmTimer OBJECT-TYPE The time after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observed only if the value of extControlAlarm is timed(2). Allowed values are 0 or 30 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.5 | TimeTicks | read-write | mandatory |
| upsAdvConfigMinReturnCapacity OBJECT-TYPE The minimum battery capacity required before the UPS will return from a low battery shutdown condition. The capacity is measured from 0% battery capacity (or Low Battery) as a percent of full capacity (100%). In other words, the UPS will not re-energize the output until the battery has charged so that its' capacity is equal to this value. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.6 | INTEGER | read-write | mandatory |
| upsAdvConfigSensitivity OBJECT-TYPE The sensitivity of the UPS to utility line abnormalities or noises. | 1.3.6.1.4.1.318.1.1.1.5.2.7 | INTEGER {auto(1), low(2), medium(3), high(4)} | read-write | mandatory |
| upsAdvConfigLowBatteryRunTime OBJECT-TYPE The desired run time of the UPS, in seconds, once the low battery condition is reached. During this time the UPS will produce a constant warning tone which can not be disabled. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets the value as the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.8 | TimeTicks | read-write | mandatory |
| upsAdvConfigReturnDelay OBJECT-TYPE The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes out of a reboot and before the UPS wakes up from 'sleep' mode. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.9 | TimeTicks | read-write | mandatory |
| upsAdvConfigShutoffDelay OBJECT-TYPE The delay in seconds the UPS remains on after being told to turn off. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used. | 1.3.6.1.4.1.318.1.1.1.5.2.10 | TimeTicks | read-write | mandatory |
| upsAdvConfigUpsSleepTime OBJECT-TYPE The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 1/10 of an hour increments. The provided value will be rounded to the closest 1/10 of an hour with one exception: Any value entered between 1 and 540 seconds will be rounded to 360 seconds (or 6 minutes). | 1.3.6.1.4.1.318.1.1.1.5.2.11 | TimeTicks | read-write | mandatory |
| upsAdvConfigSetEEPROMDefaults OBJECT-TYPE WRITE: Resets the UPS EEPROM variables to default values. READ: returns 1 | 1.3.6.1.4.1.318.1.1.1.5.2.12 | INTEGER {noSetEEPROMDefaults(1), setEEPROMDefaults(2)} | read-write | mandatory |
| upsAdvConfigDipSwitchTable OBJECT-TYPE Current settings of UPS dip switches. | 1.3.6.1.4.1.318.1.1.1.5.2.13 | not-accessible | mandatory | |
| upsAdvConfigDipSwitchEntry OBJECT-TYPE The current setting of one dip switch. | 1.3.6.1.4.1.318.1.1.1.5.2.13.1 | not-accessible | mandatory | |
| dipSwitchIndex OBJECT-TYPE The index of a UPS dip switch. | 1.3.6.1.4.1.318.1.1.1.5.2.13.1.1 | INTEGER | read-only | mandatory |
| dipSwitchStatus OBJECT-TYPE The setting of a UPS dip switch. | 1.3.6.1.4.1.318.1.1.1.5.2.13.1.2 | INTEGER {on(1), off(2)} | read-only | mandatory |
| upsAdvConfigBattExhaustThresh OBJECT-TYPE The number of seconds prior to battery exhaustion when the UPS will switch off power to its load. | 1.3.6.1.4.1.318.1.1.1.5.2.14 | TimeTicks | read-write | mandatory |
| upsAdvConfigPassword OBJECT-TYPE The password entered at the UPS front panel to enable local configuration of the EEProm. If the password is disabled or is not supported, then the agent returns a null string. | 1.3.6.1.4.1.318.1.1.1.5.2.15 | DisplayString | read-write | mandatory |
| upsAdvConfigAllowedSetTable OBJECT-TYPE The table listing the allowed values for all discrete configurable UPS variables. | 1.3.6.1.4.1.318.1.1.1.5.2.16 | not-accessible | mandatory | |
| upsAdvConfigAllowedSetEntry OBJECT-TYPE The table entry for a configurable UPS variable. | 1.3.6.1.4.1.318.1.1.1.5.2.16.1 | not-accessible | mandatory | |
| apcUpsConfigFieldIndex OBJECT-TYPE The index to an eeprom field entry. | 1.3.6.1.4.1.318.1.1.1.5.2.16.1.1 | INTEGER | read-only | mandatory |
| apcUpsConfigFieldOID OBJECT-TYPE The OID of the current configurable value. | 1.3.6.1.4.1.318.1.1.1.5.2.16.1.2 | OBJECT IDENTIFIER | read-only | mandatory |
| apcUpsConfigFieldValueRange OBJECT-TYPE The discrete set of allowed values of a configurable register. Individual values are delimited by a comma. | 1.3.6.1.4.1.318.1.1.1.5.2.16.1.3 | DisplayString | read-only | mandatory |
| upsAdvConfigBattCabAmpHour OBJECT-TYPE Configure the amp-hour setting of the UPS battery solution. The value shows the maximum battery capacity configured for the UPS when using a third party battery solution regardless of the breaker positions. The actual available battery capacity based on breaker positions or connected/disconnected battery strings, is presented in OID upsAdvBatteryTotalCapacity | 1.3.6.1.4.1.318.1.1.1.5.2.17 | INTEGER | read-write | mandatory |
| upsAdvConfigPositionSelector OBJECT-TYPE Configure UPS position selector. If the UPS doesn't support this configuration it will report unknown (1). The positions are either rack (2) for rack mounted or tower (3) for tower unit. | 1.3.6.1.4.1.318.1.1.1.5.2.18 | INTEGER {unknown(1), rack(2), tower(3)} | read-write | mandatory |
| upsAdvConfigOutputFreqRange OBJECT-TYPE Configure the output frequency tolerance range. unknown(1) indicates the output frequency is unknown. freqRangeAUTO(2) configure the output frequency range for automatic. freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 % freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 % freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 % freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 % freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 % freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 % freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 % freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 % freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 % freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 % freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 % freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 % For a list of allowed values and conditions when variable can be set by your UPS model, see the UPS User's Manual. | 1.3.6.1.4.1.318.1.1.1.5.2.19 | INTEGER {unknown(1), freqRangeAUTO(2), freqRange60Var1(3), freqRange60Var3(4), freqRange50Var1(5), freqRange50Var3(6), freqRange60Var10(7), freqRange50Var10(8), freqRange60Var1dot0(9), freqRange50Var1dot0(10), freqRange50Pct0dot5(11), freqRange50Pct1(12), freqRange50Pct2(13), freqRange50Pct4(14), freqRange50Pct6(15), freqRange50Pct8(16), freqRange60Pct0dot5(17), freqRange60Pct1(18), freqRange60Pct2(19), freqRange60Pct4(20), freqRange60Pct6(21), freqRange60Pct8(22)} | read-write | mandatory |
| upsAdvConfigUPSFail OBJECT-TYPE Configure the UPS fail action. If UPS fails, and frequency or voltage is out of range it will either GotoBypass (2) or DropLoad (3). This OID will report unknown (1) if it is not supported feature or option. | 1.3.6.1.4.1.318.1.1.1.5.2.20 | INTEGER {unknown(1), gotoBypass(2), dropLoad(3)} | read-write | mandatory |
| upsAdvConfigAlarmRedundancy OBJECT-TYPE Configure settings of UPS alarm if the redundancy is under the current redundancy. Use 0 for never. | 1.3.6.1.4.1.318.1.1.1.5.2.21 | INTEGER | read-write | mandatory |
| upsAdvConfigAlarmLoadOver OBJECT-TYPE Configure settings of UPS alarm if the load is over the current load in kVA. Use -1 for never. | 1.3.6.1.4.1.318.1.1.1.5.2.22 | INTEGER | read-write | mandatory |
| upsAdvConfigAlarmRuntimeUnder OBJECT-TYPE Configure settings of UPS alarm if the runtime is under the current time of minutes. Use -1 for never. | 1.3.6.1.4.1.318.1.1.1.5.2.23 | INTEGER | read-write | mandatory |
| upsAdvConfigVoutReporting OBJECT-TYPE Configure the way the UPS scales its output voltage readings. unknown(1) indicates the Vout Reporting is unknown. voutAUTO(2) configure the Vout Reporting for automatic scaling. vout208(3) configure the Vout Reporting for 208 Volts. vout240(4) configure the Vout Reporting for 240 Volts. | 1.3.6.1.4.1.318.1.1.1.5.2.24 | INTEGER {unknown(1), voutAUTO(2), vout208(3), vout240(4)} | read-write | mandatory |
| upsAdvConfigNumExternalBatteries OBJECT-TYPE Configure the number of external batteries connected to the UPS. | 1.3.6.1.4.1.318.1.1.1.5.2.25 | INTEGER | read-write | mandatory |
| upsAdvConfigSimpleSignalShutdowns OBJECT-TYPE Configure Simple Signal shutdown commands from the Simple Signal port to be issued to the UPS. unknown(1) indicates the Simple Signal Shutdown setting is unknown. disabled(2) configure to disable Simple Signal Shutdowns. enabled(3) configure to enable Simple Signal Shutdowns. | 1.3.6.1.4.1.318.1.1.1.5.2.26 | INTEGER {unknown(1), disabled(2), enabled(3)} | read-write | mandatory |
| upsAdvConfigMaxShutdownTime OBJECT-TYPE The maximum amount of time for server shutdown to complete before a UPS shutdown occurs. | 1.3.6.1.4.1.318.1.1.1.5.2.27 | INTEGER | read-write | mandatory |
| upsAsiUpsControlServerRequestShutdown OBJECT-TYPE Start a server shutdown sequence: serverShutdownOff: Shutdown server and turn off UPS serverShutdownReboot: Shutdown server and turn reboot UPS. | 1.3.6.1.4.1.318.1.1.1.5.2.28 | INTEGER {serverShutdownOff(1), serverShutdownReboot(2)} | read-write | mandatory |
| upsAdvConfigMinReturnRuntime OBJECT-TYPE The minimum amount of run time in seconds required before the output will be turned on, using power calculation captured at start of last shutdown. | 1.3.6.1.4.1.318.1.1.1.5.2.29 | TimeTicks | read-write | mandatory |
| upsAdvConfigBasicSignalLowBatteryDuration OBJECT-TYPE The duration of runtime in seconds during an on-battery condition at which the UPS will signal the basic low battery shutdown condition. | 1.3.6.1.4.1.318.1.1.1.5.2.30 | TimeTicks | read-write | mandatory |
| upsAdvConfigBypassPhaseLockRequired OBJECT-TYPE Sets the condition for when bypass is an acceptable mode of operation as a requirement. | 1.3.6.1.4.1.318.1.1.1.5.2.31 | INTEGER {unknown(1), disabled(2), enabled(3)} | read-write | mandatory |
| upsAdvConfigOutputFreqSlewRate OBJECT-TYPE The rate at which the UPS will change its output frequency in response to utility frequency changes. | 1.3.6.1.4.1.318.1.1.1.5.2.32 | INTEGER {unknown(1), slewRateQuarterHzPerSec(2), slewRateHalfHzPerSec(3), slewRate1HzPerSec(4), slewRate2HzPerSec(5), slewRate4HzPerSec(6), slewRate6HzPerSec(7)} | read-write | mandatory |
| upsAdvConfigChargerLevel OBJECT-TYPE Sets the rate at which the UPS charges its batteries. | 1.3.6.1.4.1.318.1.1.1.5.2.33 | INTEGER {unknown(1), low(2), high(3)} | read-write | mandatory |
| upsAdvConfigBypassToleranceSetting OBJECT-TYPE This setting allows selecting from standard bypass tolerance configurations to suit their situation. | 1.3.6.1.4.1.318.1.1.1.5.2.34 | INTEGER {unknown(1), wide(2), medium(3), narrow(4), custom(5)} | read-write | mandatory |
| upsAdvConfigMainsSetting OBJECT-TYPE Configure the type of mains supply system. singleInput (1) indicates a single supply system. dualInput (2) indicates a dual supply system. | 1.3.6.1.4.1.318.1.1.1.5.2.35 | INTEGER {singleInput(1), dualInput(2)} | read-only | mandatory |
| upsAdvConfigACWiringSetting OBJECT-TYPE Configure the AC wiring of the system. threeWire (1) indicates 3-wire system configuration. fourWire (2) indicates 4-wire system configuration. fourWireHRG (3) indicates a 4-wire High resistive Grounding system. | 1.3.6.1.4.1.318.1.1.1.5.2.36 | INTEGER {threeWire(1), fourWire(2), fourWireHRG(3)} | read-only | mandatory |
| upsAdvConfigUpperOutputVoltTolerance OBJECT-TYPE Upper tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage. | 1.3.6.1.4.1.318.1.1.1.5.2.37 | INTEGER (0..100) | read-write | mandatory |
| upsAdvConfigLowerOutputVoltTolerance OBJECT-TYPE Lower tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage. | 1.3.6.1.4.1.318.1.1.1.5.2.38 | INTEGER (0..100) | read-write | mandatory |
| upsAdvConfigUpperBypassVoltTolerance OBJECT-TYPE Upper tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage. | 1.3.6.1.4.1.318.1.1.1.5.2.39 | INTEGER (0..100) | read-write | mandatory |
| upsAdvConfigLowerBypassVoltTolerance OBJECT-TYPE Lower tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage. | 1.3.6.1.4.1.318.1.1.1.5.2.40 | INTEGER (0..100) | read-write | mandatory |
| upsAdvConfigOutofSyncBypassTransferDelay OBJECT-TYPE Configure the time (in milliseconds), indicating the gap in output voltage if an asynchronous transfer to bypass needs to occur. | 1.3.6.1.4.1.318.1.1.1.5.2.41 | INTEGER | read-write | mandatory |
| upsAdvConfigWarningAlarmDelay OBJECT-TYPE Configure the time delay for reporting warning alarms (in seconds). | 1.3.6.1.4.1.318.1.1.1.5.2.43 | INTEGER | read-write | mandatory |
| upsAdvConfigInformationalAlarmDelay OBJECT-TYPE Configure the time delay for reporting informational alarms (in seconds). | 1.3.6.1.4.1.318.1.1.1.5.2.44 | INTEGER | read-write | mandatory |
| upsAdvConfigGreenMode OBJECT-TYPE Enable/Disable UPS green mode feature. | 1.3.6.1.4.1.318.1.1.1.5.2.45 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| upsAdvConfigLCDLocalLanguage OBJECT-TYPE Configure the language setting of the UPS LCD display information. | 1.3.6.1.4.1.318.1.1.1.5.2.46 | INTEGER {english(1), french(2), italian(3), german(4), spanish(5), portuguese(6), japanese(7)} | read-write | mandatory |
| upsAdvConfigLCDLockOut OBJECT-TYPE Enable/Disable the control function of the UPS via the LCD Display. | 1.3.6.1.4.1.318.1.1.1.5.2.47 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| upsAdvConfigChargerRate OBJECT-TYPE Change the maximum allowed UPS charge rate on select products where 100% represents the manufacturer's recommended rate. A charge/discharge rate of C/10 for a 10 Ah battery would be 1 where C is defined as the charge or discharge rate equal to the capacity of a battery divided by 1 hour. To increase the charge rate by a factor of 2 to C/5, this oid would be set to 200%. This number would not change when external packs are added or removed. Charging at too high a rate can result in boiling and/or venting of electrolyte and/or high gas pressure. | 1.3.6.1.4.1.318.1.1.1.5.2.48 | INTEGER | read-write | mandatory |
| upsAdvConfigBatterySelection OBJECT-TYPE Configure the installed battery type; VRLA is a Valve Regulated Lead Acid type battery, Vented Cell is a wet cell type (car) battery, NiCd is a Nickel-Cadmium type battery, and Li-Ion is Lithium Ion type battery. Please use the OID defined under upsIdent: upsAdvEnergyStorageType | 1.3.6.1.4.1.318.1.1.1.5.2.49 | INTEGER {vrla(1), ventedcell(2), nicd(3), li-ion(4)} | read-write | mandatory |
| upsAdvConfigBatteryHealthAlarmWarningTime OBJECT-TYPE Configure the number of days before the battery health is depleted that the battery health alarm is activated. Setting this to -1, if supported by the UPS, will suppress the battery health alarm. | 1.3.6.1.4.1.318.1.1.1.5.2.50 | INTEGER | read-write | mandatory |
| upsAdvConfigBatteryHealthAlarmSleepTime OBJECT-TYPE Configure the number of days that the UPS's battery health alarm should sleep before being activated again after being acknowledged. Setting this to -1, if supported by the UPS, displays no other alarms after the first alarm is acknowledged. | 1.3.6.1.4.1.318.1.1.1.5.2.51 | INTEGER | read-write | mandatory |
| upsAdvConfigSignalFlashVoltage OBJECT-TYPE Configure the signal flash voltage in tenths of volts. | 1.3.6.1.4.1.318.1.1.1.5.2.52 | INTEGER | read-write | mandatory |
| upsAdvConfigBatteryTemperatureCompensation OBJECT-TYPE Configure the battery temperature compensation voltage in hundreds of volts per degree C. On products which support this field, the charger voltage is reduced for each degree C rise by the value configured in this setting multiplied by the number of battery cells attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.5.2.53 | INTEGER | read-write | mandatory |
| upsAdvConfigBatteryChargerType OBJECT-TYPE This OID describes type of battery charger used: standard or extended. 1 - Internal charger, 2 - Extended (CLA), 3 - Large extension (other cases), 4 - Extra large extension (XL), 5 - Double extra large extension (XXL) For other numbers charger type is unknown | 1.3.6.1.4.1.318.1.1.1.5.2.54 | INTEGER | read-write | mandatory |
| upsAdvConfigAutomaticRestart OBJECT-TYPE Indicates whether Automatic Restart is enabled or disabled. | 1.3.6.1.4.1.318.1.1.1.5.2.55 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| upsAdvConfigDeepDischargeProtection OBJECT-TYPE Indicates whether protection against deep discharge is enabled or disabled. | 1.3.6.1.4.1.318.1.1.1.5.2.56 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| upsAdvConfigFreqBypassTransferRange OBJECT-TYPE Tolerance of bypass AC frequency to switch on bypass. The frequency must be in range of -X% to +X% around the nominal value. | 1.3.6.1.4.1.318.1.1.1.5.2.57 | INTEGER | read-write | mandatory |
| upsAdvConfigUpsPowerconverterType OBJECT-TYPE This value indicates the type of UPS in terms of output phase and redundancy. 2 - Galaxy 7000 Unitary 3:3 3 - Galaxy 7000 Redundant 3:3 4 - Galaxy 7000 Parallel SSC 3:3 6 - Galaxy 7000 SSC 3:3 10 - Galaxy 300 Unitary 3:3 11 - Galaxy 300 Unitary 3:1 12 - Galaxy 300 Redundant 3:3 13 - Galaxy 300 Redundant 3:1 14 - Galaxy 5000/5500 Unitary 15 - Galaxy 5000/5500 Parallel 16 - Galaxy 5000/5500 Unitary Frequency Converter 17 - Galaxy 5000/5500 Parallel Frequency Converter For other values UPS is unknown. | 1.3.6.1.4.1.318.1.1.1.5.2.58 | INTEGER | read-write | mandatory |
| upsAdvConfigFrequencyConverterMode OBJECT-TYPE Indicates whether the output frequency is in Auto Ranging or Frequency converter mode. In Auto Ranging mode the inverter provides output frequency in the same range as the input. In Frequency converter mode it is possible to have 50Hz input and 60 Hz output and vice versa. | 1.3.6.1.4.1.318.1.1.1.5.2.59 | INTEGER {autoRanging(1), frequencyConverter(2), unknown(3)} | read-write | mandatory |
| upsAdvConfigACQualificationTime OBJECT-TYPE The time in seconds that the voltage is required to be in the acceptable range before being declared to be acceptable. | 1.3.6.1.4.1.318.1.1.1.5.2.60 | INTEGER | read-write | mandatory |
| upsControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.6 | |||
| upsBasicControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.6.1 | |||
| upsBasicControlConserveBattery OBJECT-TYPE Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.1.1 | INTEGER {noTurnOffUps(1), turnOffUpsToConserveBattery(2)} | read-write | mandatory |
| upsAdvControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.6.2 | |||
| upsAdvControlUpsOff OBJECT-TYPE Setting this variable to turnUpsOff(2) causes the UPS to shut off. When in this state, the UPS will not provide output power regardless of the input line state. Setting this variable to turnUpsOffGracefully(3) causes the UPS to shut off after a delay period. This allows the host to shut down in a graceful manner. When in this state, the UPS will not provide output power regardless of the input line state. If this UPS is an active member of a Synchronized Control Group (SCG) the turnUpsSyncGroupOff(4) command will perform a Synchronized Turn Off of all active Group members regardless of their current AC output status. If this UPS is an active member of a Synchronized Control Group (SCG) the turnUpsSyncGroupOffAfterDelay(5) command will perform a Synchronized Turn Off After Delay of all active Group members regardless of their current AC output status. This unit's Shutdown Delay will be used to execute the Turn Off After Delay command. If this UPS is an active member of an SCG, the turnUpsSyncGroupOffGracefully(6) command will perform a Synchronized Turn Off Gracefully of all active Group members regardless of their current AC output status. This unit's Maximum Shutdown Time and Shutdown Delay will be used to execute the Turn Off Gracefully command. Setting this value to noTurnUpsOff(1) has no effect. The value noTurnUpsOff(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.1 | INTEGER {noTurnUpsOff(1), turnUpsOff(2), turnUpsOffGracefully(3), turnUpsSyncGroupOff(4), turnUpsSyncGroupOffAfterDelay(5), turnUpsSyncGroupOffGracefully(6)} | read-write | mandatory |
| upsAdvControlRebootShutdownUps OBJECT-TYPE Setting this variable to rebootShutdownUps(2) causes the UPS to shut off and turn back on (as long as good AC input power is available, otherwise the UPS will remain off until good AC input power is available). Setting this variable to rebootShutdownUpsGracefully(3) causes the UPS to shut off after a delay period and then turn back on. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG) the rebootShutdownSyncGroupUps(4) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. If this UPS is an active member of a SCG the rebootShutdownSyncGroupUpsGracefully(5) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. Setting this value to noRebootShutdownUps(1) has no effect. The value noRebootShutdownUps(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.2 | INTEGER {noRebootShutdownUps(1), rebootShutdownUps(2), rebootShutdownUpsGracefully(3), rebootShutdownSyncGroupUps(4), rebootShutdownSyncGroupUpsGracefully(5)} | read-write | mandatory |
| upsAdvControlUpsSleep OBJECT-TYPE Setting this variable to putUpsToSleep(2) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime. Setting this variable to putUpsToSleepGracefully(3) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime after a delay period. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG), the putUpsSyncGroupToSleep(4) command will perform a Synchronized Sleep of all active Group members regardless of their current AC output status. This unit's Power Synchronization Delay, Shutdown Delay, Sleep Time, and Return Delay will be used to execute the sleep command. If this UPS is an active member of a SCG the putUpsSyncGroupToSleepGracefully(5) command will perform a Synchronized Sleep Gracefully of all active Group members regardless of their current AC output status. This unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Sleep Time, and Return Delay to execute the sleep command. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. Setting this value to noPutUpsToSleep(1) has no effect. The value noPutUpsToSleep(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.3 | INTEGER {noPutUpsToSleep(1), putUpsToSleep(2), putUpsToSleepGracefully(3), putUpsSyncGroupToSleep(4), putUpsSyncGroupToSleepGracefully(5)} | read-write | mandatory |
| upsAdvControlSimulatePowerFail OBJECT-TYPE Setting this variable to simulatePowerFailure(2) causes the UPS switch to battery power. Setting this value to noSimulatePowerFailure(1) has no effect. The value noSimulatePowerFailure(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.4 | INTEGER {noSimulatePowerFailure(1), simulatePowerFailure(2)} | read-write | mandatory |
| upsAdvControlFlashAndBeep OBJECT-TYPE Setting this variable to flashAndBeep(2) causes the UPS to beep and simultaneously turn on the UPS front panel lights (Smart-UPS only). If this UPS is an active member of a Synchronized Control Group (SCG), the flashAndBeepSyncGroup(3) command will Flash and Beep all active Group members regardless of current AC output status. Setting this value to noFlashAndBeep(1) has no effect. Setting this value to flashAndBeepCont (4) commandcauses the UPS to beep and light the front panel lights until the flashAndBeepCancel (5) command is received. The value noFlashAndBeep(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.5 | INTEGER {noFlashAndBeep(1), flashAndBeep(2), flashAndBeepSyncGroup(3), flashAndBeepCont(4), flashAndBeepCancel(5)} | read-write | mandatory |
| upsAdvControlTurnOnUPS OBJECT-TYPE Setting this variable to turnOnUPS(2) causes the UPS to be turned on immediately. If this UPS is an active member of a Synchronized Control Group (SCG), the turnOnUPSSyncGroup(3) command will perform a Synchronized Turn On of all active Group members regardless of their current AC output status. Setting this value to noTurnOnUPS(1) has no effect. The value noTurnOnUPS(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.6 | INTEGER {noTurnOnUPS(1), turnOnUPS(2), turnOnUPSSyncGroup(3)} | read-write | mandatory |
| upsAdvControlBypassSwitch OBJECT-TYPE This switch puts the UPS in or out of bypass mode. | 1.3.6.1.4.1.318.1.1.1.6.2.7 | INTEGER {noBypassSwitch(1), switchToBypass(2), switchOutOfBypass(3)} | read-write | mandatory |
| upsAdvControlRebootUpsWithOrWithoutAC OBJECT-TYPE Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2) causes the UPS to turn off immediately, wait for a minimum time (typically 8 seconds), and then turn back on regardless of the AC input power on the UPS. Any supported switched outlet groups will be turned off immediately but will turn on based on their individual settings (to allow on sequencing). Setting this variable to rebootUpsDelayedWithOrWithoutAC (3) causes the UPS to turn off after a delay period, wait for a minimum time (typically 8 seconds), and then turn back on regardless of the AC input power on the UPS. Any supported switched outlet groups will be turned off and on based on their individual settings (to allow off and/or on sequencing). Setting this value to noRebootUpsWithOrWithoutAC (1) has no effect. The value noRebootUpsWithOrWithoutAC (1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.6.2.8 | INTEGER {noRebootUpsWithOrWithoutAC(1), rebootUpsImmediatelyWithOrWithoutAC(2), rebootUpsDelayedWithOrWithoutAC(3)} | read-write | mandatory |
| upsAdvControlFirmwareUpdate OBJECT-TYPE Setting this variable to firmwareUpdate(2) causes the UPS to begin a firmware update if possible. Setting this value to noFirmwareUpdate(1) will clear the previous results, if any, or otherwise has no effect. Reading this variable will return noFirmwareUpdate(1) when the UPS firmware has not been updated (or previous results have been cleared), updateInProcess(3) when the UPS firmware is being updated, updateSuccessful(4) when the UPS firmware has been successfully updated, or updateFailed(5) if the UPS firmware update failed. | 1.3.6.1.4.1.318.1.1.1.6.2.9 | INTEGER {noFirmwareUpdate(1), firmwareUpdate(2), updateInProcess(3), updateSuccessful(4), updateFailed(5)} | read-write | mandatory |
| upsTest OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.7 | |||
| upsBasicTest OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.7.1 | |||
| upsAdvTest OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.7.2 | |||
| upsAdvTestDiagnosticSchedule OBJECT-TYPE The UPS system's automatic battery test schedule. | 1.3.6.1.4.1.318.1.1.1.7.2.1 | INTEGER {unknown(1), biweekly(2), weekly(3), atTurnOn(4), never(5), fourWeeks(6), twelveWeeks(7), biweeklySinceLastTest(8), weeklySinceLastTest(9), eightWeeks(10), twentysixWeeks(11), fiftytwoWeeks(12)} | read-write | mandatory |
| upsAdvTestDiagnostics OBJECT-TYPE Setting this variable to testDiagnostics(2) causes the UPS to perform a diagnostic self test. Setting this value to noTestDiagnostics(1) has no effect. The value noTestDiagnostics(1) will always be returned when the variable is read. | 1.3.6.1.4.1.318.1.1.1.7.2.2 | INTEGER {noTestDiagnostics(1), testDiagnostics(2)} | read-write | mandatory |
| upsAdvTestDiagnosticsResults OBJECT-TYPE The results of the last UPS diagnostics test performed. | 1.3.6.1.4.1.318.1.1.1.7.2.3 | INTEGER {ok(1), failed(2), invalidTest(3), testInProgress(4)} | read-only | mandatory |
| upsAdvTestLastDiagnosticsDate OBJECT-TYPE The date the last UPS diagnostics test was performed in mm/dd/yy format. | 1.3.6.1.4.1.318.1.1.1.7.2.4 | DisplayString | read-only | mandatory |
| upsAdvTestRuntimeCalibration OBJECT-TYPE Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsAdvTestCalibrationResult. | 1.3.6.1.4.1.318.1.1.1.7.2.5 | INTEGER {noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3)} | read-write | mandatory |
| upsAdvTestCalibrationResults OBJECT-TYPE The results of the last runtime calibration. Value ok(1) means a successful runtime calibration. Value invalidCalibration(2) indicates last calibration did not take place since the battery capacity was below 100%. Value calibrationInProgress(3) means a calibration is occurring now. Value refused(4) means the test was refused, it did not take place. Value aborted(5) indicates the test started but either someone cancelled it or the system encountered an error. Value pending(6) the test will commence shortly. | 1.3.6.1.4.1.318.1.1.1.7.2.6 | INTEGER {ok(1), invalidCalibration(2), calibrationInProgress(3), refused(4), aborted(5), pending(6), unknown(7)} | read-only | mandatory |
| upsAdvTestCalibrationDate OBJECT-TYPE The date the last UPS runtime calibration was performed in mm/dd/yy format. | 1.3.6.1.4.1.318.1.1.1.7.2.7 | DisplayString | read-only | mandatory |
| upsAdvTestDiagnosticTime OBJECT-TYPE The time of the day to perform automatic battery test. Expressed in 24 hour notation - hh:mm. | 1.3.6.1.4.1.318.1.1.1.7.2.8 | DisplayString | read-write | mandatory |
| upsAdvTestDiagnosticDay OBJECT-TYPE The day of the week to perform automatic battery test. | 1.3.6.1.4.1.318.1.1.1.7.2.9 | INTEGER {monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7)} | read-write | mandatory |
| upsAdvTestBatteryInterval OBJECT-TYPE The UPS system's automatic battery test period. | 1.3.6.1.4.1.318.1.1.1.7.2.10 | DisplayString | read-write | mandatory |
| upsAdvTestCalibrationLastSuccessfulDate OBJECT-TYPE The latest date when the UPS performed a successful runtime calibration test. The format is YYYY-MM-DD | 1.3.6.1.4.1.318.1.1.1.7.2.11 | DisplayString | read-only | mandatory |
| upsAdvTestBatteryLastSuccessfulDate OBJECT-TYPE The latest date when the UPS performed a successful battery diagnostic test (battery monitoring test). The format is YYYY-MM-DD | 1.3.6.1.4.1.318.1.1.1.7.2.12 | DisplayString | read-only | mandatory |
| upsAdvTestBatteryLastDate OBJECT-TYPE The latest date when the UPS performed a battery diagnostic test (battery monitoring test), regardless of the test result. The format is YYYY-MM-DD | 1.3.6.1.4.1.318.1.1.1.7.2.13 | DisplayString | read-only | optional |
| upsAdvTestBatteryProcessStatus OBJECT-TYPE The results of the latest battery diagnostic test (battery monitoring test). ok(1) indicates a successful completion of the test. preconditionNotMeet(2) indicates that the test did not start, due to low capacity or low load. batteryTestInProgress(3) indicates that a test is in progress. refused(4) indicates that the test was refused and did not take place. aborted(5) indicates that the test started but it was either cancelled or the system encountered an error. pending(6) the test will commence shortly. | 1.3.6.1.4.1.318.1.1.1.7.2.14 | INTEGER {ok(1), preconditionNotMeet(2), batteryTestInProgress(3), refused(4), aborted(5), pending(6), unknown(7)} | read-only | mandatory |
| upsAdvTestBatteryConditionStatus OBJECT-TYPE Result of the latest successful test 1 = unknown 2 = battery OK 3 = battery capacity decreased 4 = battery defect | 1.3.6.1.4.1.318.1.1.1.7.2.15 | INTEGER {unknown(1), batteryOK(2), batteryCapacityDecreased(3), batteryDefect(4)} | read-only | mandatory |
| upsAdvTestDiagnosticsBatteryInterval OBJECT-TYPE The battery test is a diagnostic test (also referred to as battery monitoring test). The test will be performed on the day stated in upsAdvTestDiagnosticDay and at the time stated in upsAdvTestDiagnosticTime. The result can be read in upsAdvTestBatteryConditionStatus. 1 = Never 2 = Weekly 3 = biweekly 4 = Every 4 weeks 5 = Every 8 weeks 6 = Every 12 weeks 7 = Every 26 weeks 8 = Every 52 weeks | 1.3.6.1.4.1.318.1.1.1.7.2.16 | INTEGER {never(1), weekly(2), biweekly(3), every4weeks(4), every8weeks(5), every12weeks(6), every26weeks(7), every52weeks(8)} | read-only | mandatory |
| upsComm OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.8 | |||
| upsCommStatus OBJECT-TYPE The status of agent's communication with UPS. | 1.3.6.1.4.1.318.1.1.1.8.1 | INTEGER {ok(1), noComm(2)} | read-only | mandatory |
| upsPhase OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.9 | |||
| upsPhaseResetValues OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.9.1 | |||
| upsPhaseResetMaxMinValues OBJECT-TYPE Reset the maximum and minimum UPS values: upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage, upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent, upsPhaseInputMaxPower, upsPhaseInputMinPower, upsPhaseOutputMaxCurrent, upsPhaseOutputMinCurrent, upsPhaseOutputMaxLoad, upsPhaseOutputMinLoad, upsPhaseOutputMaxPercentLoad, upsPhaseOutputMinPercentLoad, upsPhaseOutputMaxPower, upsPhaseOutputMinPower, upsPhaseOutputMaxPercentPower, upsPhaseOutputMinPercentPower. | 1.3.6.1.4.1.318.1.1.1.9.1.1 | INTEGER {none(1), reset(2)} | read-write | mandatory |
| upsPhaseInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.9.2 | |||
| upsPhaseNumInputs OBJECT-TYPE The number of input feeds to this device. This variable indicates the number of rows in the input table. | 1.3.6.1.4.1.318.1.1.1.9.2.1 | INTEGER | read-only | mandatory |
| upsPhaseInputTable OBJECT-TYPE A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs. | 1.3.6.1.4.1.318.1.1.1.9.2.2 | not-accessible | mandatory | |
| upsPhaseInputEntry OBJECT-TYPE An entry containing information applicable to a particular input. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1 | not-accessible | mandatory | |
| upsPhaseInputTableIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1.1 | INTEGER | read-only | mandatory |
| upsPhaseNumInputPhases OBJECT-TYPE The number of input phases utilized in this device. The sum of all the upsPhaseNumInputPhases variable indicates the number of rows in the input phase table. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1.2 | INTEGER | read-only | mandatory |
| upsPhaseInputVoltageOrientation OBJECT-TYPE The input voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1.3 | INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)} | read-only | mandatory |
| upsPhaseInputFrequency OBJECT-TYPE The input frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1.4 | INTEGER | read-only | mandatory |
| upsPhaseInputType OBJECT-TYPE The input type. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1.5 | INTEGER {unknown(1), main(2), bypass(3)} | read-only | mandatory |
| upsPhaseInputName OBJECT-TYPE A name given to a particular input. | 1.3.6.1.4.1.318.1.1.1.9.2.2.1.6 | DisplayString | read-write | mandatory |
| upsPhaseInputPhaseTable OBJECT-TYPE A list of input table entries. The number of entries is given by the sum of the upsPhaseNumInputPhases. | 1.3.6.1.4.1.318.1.1.1.9.2.3 | not-accessible | mandatory | |
| upsPhaseInputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input phase. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1 | not-accessible | mandatory | |
| upsPhaseInputPhaseTableIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.1 | INTEGER | read-only | mandatory |
| upsPhaseInputPhaseIndex OBJECT-TYPE The input phase identifier. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.2 | INTEGER | read-only | mandatory |
| upsPhaseInputVoltage OBJECT-TYPE The input voltage in VAC, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3 | INTEGER | read-only | mandatory |
| upsPhaseInputMaxVoltage OBJECT-TYPE The maximum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.4 | INTEGER | read-only | mandatory |
| upsPhaseInputMinVoltage OBJECT-TYPE The minimum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.5 | INTEGER | read-only | mandatory |
| upsPhaseInputCurrent OBJECT-TYPE The input current in 0.1 amperes, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.6 | INTEGER | read-only | mandatory |
| upsPhaseInputMaxCurrent OBJECT-TYPE The maximum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.7 | INTEGER | read-only | mandatory |
| upsPhaseInputMinCurrent OBJECT-TYPE The minimum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.8 | INTEGER | read-only | mandatory |
| upsPhaseInputPower OBJECT-TYPE The input power in Watts, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.9 | INTEGER | read-only | mandatory |
| upsPhaseInputMaxPower OBJECT-TYPE The maximum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.10 | INTEGER | read-only | mandatory |
| upsPhaseInputMinPower OBJECT-TYPE The minimum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.11 | INTEGER | read-only | mandatory |
| upsPhaseInputApparentPower OBJECT-TYPE The input apparent power of the UPS in kVA. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.12 | INTEGER | read-only | mandatory |
| upsPhaseInputPowerFactor OBJECT-TYPE The input power factor measured in hundredth. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.13 | INTEGER | read-only | mandatory |
| upsPhaseInputVoltagePN OBJECT-TYPE The input voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.2.3.1.14 | INTEGER | read-only | mandatory |
| upsPhaseOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.9.3 | |||
| upsPhaseNumOutputs OBJECT-TYPE The number of output feeds to this device. This variable indicates the number of rows in the output table. | 1.3.6.1.4.1.318.1.1.1.9.3.1 | INTEGER | read-only | mandatory |
| upsPhaseOutputTable OBJECT-TYPE A list of output table entries. The number of entries is given by the value of upsOutputNumPhases. | 1.3.6.1.4.1.318.1.1.1.9.3.2 | not-accessible | mandatory | |
| upsPhaseOutputEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.1.9.3.2.1 | not-accessible | mandatory | |
| upsPhaseOutputTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.1.9.3.2.1.1 | INTEGER | read-only | mandatory |
| upsPhaseNumOutputPhases OBJECT-TYPE The number of output phases utilized in this device. The sum of all the upsPhaseNumOutputPhases variable indicates the number of rows in the output phase table. | 1.3.6.1.4.1.318.1.1.1.9.3.2.1.2 | INTEGER | read-only | mandatory |
| upsPhaseOutputVoltageOrientation OBJECT-TYPE The output voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1. | 1.3.6.1.4.1.318.1.1.1.9.3.2.1.3 | INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)} | read-only | mandatory |
| upsPhaseOutputFrequency OBJECT-TYPE The output frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.2.1.4 | INTEGER | read-only | mandatory |
| upsPhaseOutputPhaseTable OBJECT-TYPE A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases. | 1.3.6.1.4.1.318.1.1.1.9.3.3 | not-accessible | mandatory | |
| upsPhaseOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular output phase. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1 | not-accessible | mandatory | |
| upsPhaseOutputPhaseTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.1 | INTEGER | read-only | mandatory |
| upsPhaseOutputPhaseIndex OBJECT-TYPE The output phase identifier. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.2 | INTEGER | read-only | mandatory |
| upsPhaseOutputVoltage OBJECT-TYPE The output voltage in VAC, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.3 | INTEGER | read-only | mandatory |
| upsPhaseOutputCurrent OBJECT-TYPE The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.4 | INTEGER | read-only | mandatory |
| upsPhaseOutputMaxCurrent OBJECT-TYPE The maximum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.5 | INTEGER | read-only | mandatory |
| upsPhaseOutputMinCurrent OBJECT-TYPE The minimum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.6 | INTEGER | read-only | mandatory |
| upsPhaseOutputLoad OBJECT-TYPE The output load in VA, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.7 | INTEGER | read-only | mandatory |
| upsPhaseOutputMaxLoad OBJECT-TYPE The maximum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.8 | INTEGER | read-only | mandatory |
| upsPhaseOutputMinLoad OBJECT-TYPE The minimum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.9 | INTEGER | read-only | mandatory |
| upsPhaseOutputPercentLoad OBJECT-TYPE The percentage of the UPS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.10 | INTEGER | read-only | mandatory |
| upsPhaseOutputMaxPercentLoad OBJECT-TYPE The maximum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.11 | INTEGER | read-only | mandatory |
| upsPhaseOutputMinPercentLoad OBJECT-TYPE The minimum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.12 | INTEGER | read-only | mandatory |
| upsPhaseOutputPower OBJECT-TYPE The output power in Watts, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.13 | INTEGER | read-only | mandatory |
| upsPhaseOutputMaxPower OBJECT-TYPE The maximum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.14 | INTEGER | read-only | mandatory |
| upsPhaseOutputMinPower OBJECT-TYPE The minimum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.15 | INTEGER | read-only | mandatory |
| upsPhaseOutputPercentPower OBJECT-TYPE The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.16 | INTEGER | read-only | mandatory |
| upsPhaseOutputMaxPercentPower OBJECT-TYPE The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.17 | INTEGER | read-only | mandatory |
| upsPhaseOutputMinPercentPower OBJECT-TYPE The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.18 | INTEGER | read-only | mandatory |
| upsPhaseOutputPowerFactor OBJECT-TYPE The Output power factor of the UPS in hundredth. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.19 | INTEGER | read-only | mandatory |
| upsPhaseOutputApparentPower OBJECT-TYPE Apparent power in kVA | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.20 | INTEGER | read-only | mandatory |
| upsPhaseOutputInverterVoltage OBJECT-TYPE Output voltage in VAC measured at the output of inverter. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.21 | INTEGER | read-only | mandatory |
| upsPhaseOutputVoltagePN OBJECT-TYPE The output voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.9.3.3.1.22 | INTEGER | read-only | mandatory |
| upsSyncCtrlGroup OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.10 | |||
| upsSyncCtrlGroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.10.1 | |||
| upsSCGMembershipGroupNumber OBJECT-TYPE The SCG Membership Group number (MGN) is a 16-bit number allowing up to 65534 separate groups that can be identified and distinguished per IP subnet. Zero and 65535 are not used. The MGN is used in all communication between members of the SCG and a Network Management Card (NMC) will listen and only respond to commands sent to it using its configured SCG ID. | 1.3.6.1.4.1.318.1.1.1.10.1.1 | INTEGER | read-write | mandatory |
| upsSCGActiveMembershipStatus OBJECT-TYPE Membership in the configured SCG can be enabled and disabled. If an NMC is configured for an SCG, but has its membership disabled, all synchronized control commands received will be ignored. | 1.3.6.1.4.1.318.1.1.1.10.1.2 | INTEGER {enabledSCG(1), disabledSCG(2)} | read-write | mandatory |
| upsSCGPowerSynchronizationDelayTime OBJECT-TYPE The Power Synchronization Delay Time (PSD) setting is the maximum number of seconds an SCG Initiator will wait for all SCG members to recover utility power before completing the reboot sequence of a reboot or sleep command. If all SCG members are ready to proceed, no additional delay is introduced. | 1.3.6.1.4.1.318.1.1.1.10.1.3 | INTEGER | read-write | mandatory |
| upsSCGReturnBatteryCapacityOffset OBJECT-TYPE A reboot command uses the Initiator's Return battery Capacity (RBC) to control when the SCG completes this operation. In a Normal Control Operation (NCC) the UPS will only complete the reboot if RBC is reached. Due to normal battery charge rate variations it may be desirable for the Followers to complete the reboot if they are within some range of the Initiator's RBC when the Initiator is prepared (charged to RBC) to complete the reboot. The Return Battery Capacity Offset (RBCO) defines a percent battery capacity subtracted from an RBC above which a Follower's battery must be charged for it to complete a reboot. For example, if the Initiator's RBC is 50% and the Initiator's RBCO is 5% then a Follower's battery capacity is within range if it is greater or equal to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot command. The default RBCO is 10%. | 1.3.6.1.4.1.318.1.1.1.10.1.4 | INTEGER | read-write | mandatory |
| upsSCGMultiCastIP OBJECT-TYPE The MultiCast IP address of the SCG Group. | 1.3.6.1.4.1.318.1.1.1.10.1.5 | IpAddress | read-write | mandatory |
| upsSyncCtrlGroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.10.2 | |||
| upsSCGNumOfGroupMembers OBJECT-TYPE The number of active, communicating members in the Sync Control Group (SCG). This variable indicates the number of rows in the SCG Status Table. | 1.3.6.1.4.1.318.1.1.1.10.2.1 | INTEGER | read-only | mandatory |
| upsSCGStatusTable OBJECT-TYPE A list of SCG status table entries. The number of entries is given by the value of upsSCGNumOfGroupMembers. | 1.3.6.1.4.1.318.1.1.1.10.2.2 | not-accessible | mandatory | |
| upsSCGStatusEntry OBJECT-TYPE An entry containing information applicable to a particular SCG Member. | 1.3.6.1.4.1.318.1.1.1.10.2.2.1 | not-accessible | mandatory | |
| upsSCGStatusTableIndex OBJECT-TYPE The index of a status entry for an active, communicating SCG member. | 1.3.6.1.4.1.318.1.1.1.10.2.2.1.1 | INTEGER | read-only | mandatory |
| upsSCGMemberIP OBJECT-TYPE The IP address of an active, communicating SCG Member. | 1.3.6.1.4.1.318.1.1.1.10.2.2.1.2 | IpAddress | read-only | mandatory |
| upsSCGACInputStatus OBJECT-TYPE This OID indicates the AC Input Status of the SCG Member. acInGood(1) indicates the AC Input is within tolerance. acInBad(2) indicates the AC Input is not within tolerance. | 1.3.6.1.4.1.318.1.1.1.10.2.2.1.3 | INTEGER {acInGood(1), acInBad(2)} | read-only | mandatory |
| upsSCGACOutputStatus OBJECT-TYPE This OID indicates the AC Output Status of the SCG Member. acOutOn(1) indicates the UPS output is providing power to the load. acOutOff(2) indicates the UPS output is not providing power to the load. | 1.3.6.1.4.1.318.1.1.1.10.2.2.1.4 | INTEGER {acOutOn(1), acOutOff(2)} | read-only | mandatory |
| upsState OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.11 | |||
| upsBasicState OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.11.1 | |||
| upsBasicStateOutputState OBJECT-TYPE An ASCII string containing the 64 flags representing the current state(s) of the UPS. If the Network Card is unable to determine the state of the UPS, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 64, read from left to right. The flags are defined as follows: Flag 1: Abnormal Condition Present Flag 2: On Battery Flag 3: Low Battery Flag 4: On Line Flag 5: Replace Battery Flag 6: Serial Communication Established Flag 7: AVR Boost Active Flag 8: AVR Trim Active Flag 9: Overload Flag 10: Runtime Calibration Flag 11: Batteries Discharged Flag 12: Manual Bypass Flag 13: Software Bypass Flag 14: In Bypass due to Internal Fault Flag 15: In Bypass due to Supply Failure Flag 16: In Bypass due to Fan Failure Flag 17: Sleeping on a Timer Flag 18: Sleeping until Utility Power Returns Flag 19: On Flag 20: Rebooting Flag 21: Battery Communication Lost Flag 22: Graceful Shutdown Initiated Flag 23: Smart Boost or Smart Trim Fault Flag 24: Bad Output Voltage Flag 25: Battery Charger Failure Flag 26: High Battery Temperature Flag 27: Warning Battery Temperature Flag 28: Critical Battery Temperature Flag 29: Self Test In Progress Flag 30: Low Battery / On Battery Flag 31: Graceful Shutdown Issued by Upstream Device Flag 32: Graceful Shutdown Issued by Downstream Device Flag 33: No Batteries Attached Flag 34: Synchronized Command is in Progress Flag 35: Synchronized Sleeping Command is in Progress Flag 36: Synchronized Rebooting Command is in Progress Flag 37: Inverter DC Imbalance Flag 38: Transfer Relay Failure Flag 39: Shutdown or Unable to Transfer Flag 40: Low Battery Shutdown Flag 41: Electronic Unit Fan Failure Flag 42: Main Relay Failure Flag 43: Bypass Relay Failure Flag 44: Temporary Bypass Flag 45: High Internal Temperature Flag 46: Battery Temperature Sensor Fault Flag 47: Input Out of Range for Bypass Flag 48: DC Bus Overvoltage Flag 49: PFC Failure Flag 50: Critical Hardware Fault Flag 51: Green Mode/ECO Mode Flag 52: Hot Standby Flag 53: Emergency Power Off (EPO) Activated Flag 54: Load Alarm Violation Flag 55: Bypass Phase Fault Flag 56: UPS Internal Communication Failure Flag 57: Efficiency Booster Mode Flag 58: Off Flag 59: Standby Flag 60: Minor or Environment Alarm Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.1.1 | DisplayString | read-only | mandatory |
| upsBasicStateAlarmStatus OBJECT-TYPE The alarm status of the Power Module. noAlarms(1) indicates the device has no alarms present. infoAlarm (2) indicates the device has alarms and the highest severity of the alarms present is infomational. warningAlarm (3) indicates the device has alarms and the highest severity of the alarms present is warning. criticalAlarm (4) indicates the device has alarms and the highest severity of the alarms present is critical. | 1.3.6.1.4.1.318.1.1.1.11.1.2 | INTEGER {noAlarms(1), infoAlarm(2), warningAlarm(3), criticalAlarm(4)} | read-only | mandatory |
| upsAdvState OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.11.2 | |||
| upsAdvStateAbnormalConditions OBJECT-TYPE An ASCII string containing the 32 flags representing the current active UPS faults. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If this variable is not supported by the connected UPS, this variable is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 32, and read from left to right. The flags are defined as follows: Flag 1: Power Module Failure Flag 2: Main Intelligence Module Failure Flag 3: Redundant Intelligence Module Failure Flag 4: Battery Failure Flag 5: Load(kVA) Alarm Threshold Violation Flag 6: Redundancy Lost Flag 7: Redundancy Below Alarm Threshold Flag 8: Bypass not in Range; Either Frequency or Voltage Flag 9: Bypass Contactor Stuck in Bypass Condition Flag 10: Bypass Contactor Stuck in On-Line Condition Flag 11: In Bypass due to an Internal Fault Flag 12: In Bypass due to an Overload Flag 13: In Maintenance Bypass Flag 14: Input Circuit Braker Tripped Open Flag 15: System Level Fan Failure Flag 16: Redundant Intelligent Module in Control Flag 17: IIC Inter-Module Communication Failure Flag 18: No Working Power Modules Flag 19: Load Shutdown From Bypass; Input Frequency Flag 20: Runtime Below Alarm Threshold Flag 21: Extended Run Frame Fault Flag 22: Output Voltage out of Range Flag 23: UPS Not Synchronized Flag 24: No Batteries Installed Flag 25: Battery Voltage High Flag 26: UPS Specific Fault Detected Flag 27: Site Wiring Fault Flag 28: Backfeed Protection Relay Opened Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.2.1 | DisplayString | read-only | mandatory |
| upsAdvStateSymmetra3PhaseSpecificFaults OBJECT-TYPE An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra 3-Phase UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: External Switch Gear Failure Flag 2: External Transformer Over Temperature Flag 3: External DC Circuit Breaker Tripped Flag 4: System Power Supply Failure Flag 5: Battery Monitor Card Failure Flag 6: Battery Monitor Card Removed Flag 7: XR Communication Card Failure Flag 8: XR Communication Card Removed Flag 9: External Switch Gear Monitoring Card Failure Flag 10: External Switch Gear Monitoring Card Removed Flag 11: Internal DC Circuit Breaker Tripped Flag 12: Static Bypass Switch Failure Flag 13: System EEPROM Removed Flag 14: System EEPROM Failure Flag 15: UPS in Forced Bypass Flag 16: Static Bypass Switch Module Removed Flag 17: System Start-Up Configuration Fault Flag 18: Battery Charger Shutdown Externally Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> Flag 33: <Not Used> Flag 34: <Not Used> Flag 35: <Not Used> Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: <Not Used> Flag 47: <Not Used> Flag 48: <Not Used> Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.2.2 | DisplayString | read-only | mandatory |
| upsAdvStateDP300ESpecificFaults OBJECT-TYPE An ASCII string containing the 64 flags representing the current active UPS specific faults for the Silcon DP300E UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: Peak Current Limiter Active Flag 2: Bypass Power Supply Fault Flag 3: Delta Current Limiter Active Flag 4: Fan Fault Flag 5: High DC warning Flag 6: Inverter Voltage Error Flag 7: Parallel Synchronization Error Flag 8: Second Power Supply Fault Flag 9: Internal Power Supply Fault Flag 10: <Not Used> Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: Bypass Static Switch High Temperature Flag 15: High Battery Temperature Flag 16: Battery Weak Flag 17: <Not Used> Flag 18: System Locked in Operation Mode Flag 19: RAM1 Memory Write Error Flag 20: Memory Write Error Flag 21: Communication to VQ Bypass Lost Flag 22: Communication to VQ Output Lost Flag 23: Communication to DMU Lost Flag 24: Communication to Controller Lost Flag 25: Communication to Parallel IF Lost Flag 26: External Shutdown Accepted Flag 27: DC Capacitor Charge Error Flag 28: Communication to VQ Mains Lost Flag 29: Bypass Synchronization Error Flag 30: Charge Error Flag 31: SII Aux Input Activiated Flag 32: <Not Used> Flag 33: Blown Inverter Fuse Flag 34: Blown Rectifier Fuse Flag 35: Auxilliary 1 Fault Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: High Temperature Charger Magnetic Flag 47: <Not Used> Flag 48: Battery Monitor Warning Flag 49: Battery Monitor Alarm Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: TSM 1/2/3 Temperature Shutdown Flag 54: Charger 0/30 Temperature Warning Flag 55: Charger 0/30 Temperature Shutdown Flag 56: High Output Voltage Flag 57: SSW Temperature Over 90 Flag 58: <Not Used> Flag 59: Low Current Failure In AC Capacitors Flag 60: <Not Used> Flag 61: Advanced Battery Management Not Installed Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.2.3 | DisplayString | read-only | mandatory |
| upsAdvStateSymmetraSpecificFaults OBJECT-TYPE An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: System Fault Flag 2: Bypass Relay Fault Flag 3: Power Module Turn Off Failure Flag 4: Frame Identification Fault Flag 5: <Not Used> Flag 6: <Not Used> Flag 7: <Not Used> Flag 8: <Not Used> Flag 9: <Not Used> Flag 10: <Not Used> Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used> Flag 17: <Not Used> Flag 18: <Not Used> Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> Flag 33: <Not Used> Flag 34: <Not Used> Flag 35: <Not Used> Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: <Not Used> Flag 47: <Not Used> Flag 48: <Not Used> Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.2.4 | DisplayString | read-only | mandatory |
| upsAdvStateSmartUPSSpecificFaults OBJECT-TYPE An ASCII string containing the 64 flags representing the current active UPS specific faults for the Smart-UPS UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: EPO Switch Activated Flag 2: Static Bypass Switch Fault Flag 3: System Configuration Fault Flag 4: Power Supply Unit Fault Flag 5: Weak Battery Flag 6: High Battery Temperature Flag 7: Internal Mechanical Bypass Flag 8: Loss Of Parallel Redundancy Flag 9: Parallel Bus Communication Fault on Cable 1 Flag 10: Parallel Bus Communication Fault on Cable 2 Flag 11: Auxiliary Bus Communication Fault Flag 12: Parallel Bus Termination Fault on Cable 1 Flag 13: Parallel Bus Termination Fault on Cable 2 Flag 14: Auxiliary Bus Termination Fault Flag 15: No Master Present In The Parallel System Flag 16: Overload on a Parallel Unit Flag 17: Parallel Configuration Fault Flag 18: <Not Used> Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> Flag 33: <Not Used> Flag 34: <Not Used> Flag 35: <Not Used> Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: <Not Used> Flag 47: <Not Used> Flag 48: <Not Used> Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.2.5 | DisplayString | read-only | mandatory |
| upsAdvStateSystemMessages OBJECT-TYPE An ASCII string containing the 3 digit Decimal code representing the current active message from the System Message Register. Each code should remain active for a minimum of 15 seconds. However, in the worst case scenario, a code could be cleared after only 5 seconds. It is recommended that this object be polled at least once every 4 seconds in order to get the most accurate representation of the current UPS System Message. If the Network Card is unable to determine the value of the System Message Register, this variable is set to 'UNKNOWN'. | 1.3.6.1.4.1.318.1.1.1.11.2.6 | DisplayString | read-only | mandatory |
| upsAdvStateTotaltimeonbattery OBJECT-TYPE Total time the UPS has been in battery operation. | 1.3.6.1.4.1.318.1.1.1.11.2.7 | DisplayString | read-only | mandatory |
| upsAdvStateTotaltimeonbypass OBJECT-TYPE Total time the UPS has been in bypass operation. | 1.3.6.1.4.1.318.1.1.1.11.2.8 | DisplayString | read-only | mandatory |
| upsAdvStateTotaltimeonNormal OBJECT-TYPE Total time the UPS has been in normal operation. | 1.3.6.1.4.1.318.1.1.1.11.2.9 | DisplayString | read-only | mandatory |
| upsAdvStateNumberoftimesonbattery OBJECT-TYPE Number of times the UPS was on battery. Since the last reset of statistical data. | 1.3.6.1.4.1.318.1.1.1.11.2.10 | INTEGER | read-only | mandatory |
| upsAdvStateNumberoftimesbypass OBJECT-TYPE Number of times the UPS was in bypass. Since the last reset of statistical data. | 1.3.6.1.4.1.318.1.1.1.11.2.11 | INTEGER | read-only | mandatory |
| upsAdvStateNumberoftimesNormal OBJECT-TYPE Number of times the UPS was in normal operation. Since the last reset of statistical data. | 1.3.6.1.4.1.318.1.1.1.11.2.12 | INTEGER | read-only | mandatory |
| upsAdvStateEcomode OBJECT-TYPE Eco mode status. 1: UPS is on Eco-mode 2: UPS is not on Eco-mode. | 1.3.6.1.4.1.318.1.1.1.11.2.13 | INTEGER {upsOnEcoMode(1), upsNotOnEcoMode(2)} | read-only | mandatory |
| upsAdvStateLifeCycleManagement OBJECT-TYPE An ASCII string containing the 16 flags representing the life cycle management alerts for the device. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 16, and read from left to right. The bits are defined as follows: Flag 1: End of Warranty Soon Flag 2: Battery Check Recommended Flag 3: Service Period On Wearing Parts Expired Flag 4: Secure Start-up Recommended Flag 5: Fan Life Expired Flag 6: DC Capacitor Life Expired Flag 7: AC Capacitor Life Expired Flag 8: Supply Service Life Expired Flag 9: Ups Out Of Limits Warning Flag 10: Air Filter Life Expired Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used> | 1.3.6.1.4.1.318.1.1.1.11.2.14 | DisplayString | read-only | mandatory |
| upsOutletGroups OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.12 | |||
| upsOutletGroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.12.1 | |||
| upsOutletGroupStatusTableSize OBJECT-TYPE The number of outlet groups for the UPS. | 1.3.6.1.4.1.318.1.1.1.12.1.1 | INTEGER | read-only | mandatory |
| upsOutletGroupStatusTable OBJECT-TYPE Allows for getting status of the outlet groups. The number of entries is contained in the upsOutletGroupStatusTableSize OID. | 1.3.6.1.4.1.318.1.1.1.12.1.2 | not-accessible | mandatory | |
| upsOutletGroupStatusEntry OBJECT-TYPE The outlet group status to get. | 1.3.6.1.4.1.318.1.1.1.12.1.2.1 | not-accessible | mandatory | |
| upsOutletGroupStatusIndex OBJECT-TYPE The index to the outlet group entry. | 1.3.6.1.4.1.318.1.1.1.12.1.2.1.1 | INTEGER | read-only | mandatory |
| upsOutletGroupStatusName OBJECT-TYPE The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID. | 1.3.6.1.4.1.318.1.1.1.12.1.2.1.2 | DisplayString | read-only | mandatory |
| upsOutletGroupStatusGroupState OBJECT-TYPE Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupStatusOn (1) value will be returned. If the outlet group is off, the upsOutletGroupStatusOff (2) value will be returned. If the state of the outlet group cannot be determined, the upsOutletGroupStatusUnknown (3) value will be returned. | 1.3.6.1.4.1.318.1.1.1.12.1.2.1.3 | INTEGER {upsOutletGroupStatusOn(1), upsOutletGroupStatusOff(2), upsOutletGroupStatusUnknown(3)} | read-only | mandatory |
| upsOutletGroupStatusCommandPending OBJECT-TYPE Getting this variable will return the command pending state of the outlet group. If a command is pending on the outlet group, the upsOutletGroupCommandPending (1) value will be returned. If there is not a command pending on the outlet group, the upsOutletGroupNoCommandPending (2) will be returned. | 1.3.6.1.4.1.318.1.1.1.12.1.2.1.4 | INTEGER {upsOutletGroupCommandPending(1), upsOutletGroupNoCommandPending(2)} | read-only | mandatory |
| upsOutletGroupStatusOutletType OBJECT-TYPE Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail. | 1.3.6.1.4.1.318.1.1.1.12.1.2.1.5 | INTEGER {upsSwitchedOutletGroup(1), upsMainOutletGroup(2)} | read-only | mandatory |
| upsOutletGroupStatusGroupFullState OBJECT-TYPE An ASCII string containing the 32 flags representing the current state(s) of the outlet group. If the Network Card is unable to determine the state of the outlet group, this variable is set to 'UNKNOWN'. The flags are numbered from 1 to 32, and read from left to right. The flags are defined as follows: Flag 1: On Flag 2: Off Flag 3: Reboot in Progress Flag 4: Shutdown in Progress Flag 5: Sleep in Progress Flag 6: <Not Used> Flag 7: <Not Used> Flag 8: Pending Load Shed Flag 9: Pending On Delay Flag 10: Pending Off Delay Flag 11: Pending AC Presence Flag 12: Pending On Minimum Runtime Flag 13: Member Group Process 1 Flag 14: Member Group Process 2 Flag 15: Runtime Below Turn On Setting Flag 16: <Not Used> Flag 17: <Not Used> Flag 18: <Not Used> Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> | 1.3.6.1.4.1.318.1.1.1.12.1.2.1.6 | DisplayString | read-only | mandatory |
| upsOutletGroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.12.2 | |||
| upsOutletGroupConfigTableSize OBJECT-TYPE The number of outlet groups for the UPS. | 1.3.6.1.4.1.318.1.1.1.12.2.1 | INTEGER | read-only | mandatory |
| upsOutletGroupConfigTable OBJECT-TYPE The list of outlet groups to configure. The number of entries is defined by the upsOutletGroupConfigTableSize OID. | 1.3.6.1.4.1.318.1.1.1.12.2.2 | not-accessible | mandatory | |
| upsOutletGroupConfigEntry OBJECT-TYPE The outlet groups to configure. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1 | not-accessible | mandatory | |
| upsOutletGroupConfigIndex OBJECT-TYPE The index to the outlet group entry. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 | INTEGER | read-only | mandatory |
| upsOutletGroupConfigName OBJECT-TYPE The name of the outlet group. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 | DisplayString | read-write | mandatory |
| upsOutletGroupConfigPowerOnDelay OBJECT-TYPE The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the UPS and the outlet group. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 | INTEGER | read-write | mandatory |
| upsOutletGroupConfigPowerOffDelay OBJECT-TYPE The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the UPS and the outlet group. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 | INTEGER | read-write | mandatory |
| upsOutletGroupConfigRebootDuration OBJECT-TYPE During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turning the power off, at the start of the sequence, before initiating the power on sequence. Allowed values vary by UPS model. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 | INTEGER | read-write | mandatory |
| upsOutletGroupConfigMinReturnRuntime OBJECT-TYPE In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runtime (seconds) that is required in order to power the Outlet Group on. Allowed values vary by UPS model. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 | INTEGER | read-write | mandatory |
| upsOutletGroupConfigOutletType OBJECT-TYPE Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.7 | INTEGER {upsSwitchedOutletGroup(1), upsMainOutletGroup(2)} | read-only | mandatory |
| upsOutletGroupConfigLoadShedControlSkipOffDelay OBJECT-TYPE Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situation, where applicable. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 | INTEGER {upsOutletGroupConfigSkipOffDelay(1), upsOutletGroupConfigUseOffDelay(2)} | read-write | mandatory |
| upsOutletGroupConfigLoadShedControlAutoRestart OBJECT-TYPE Configures whether the outlet group will automatically restart after a load shedding situation, where applicable. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 | INTEGER {upsOutletGroupConfigAutoRestart(1), upsOutletGroupConfigManualRestart(2)} | read-write | mandatory |
| upsOutletGroupConfigLoadShedControlTimeOnBattery OBJECT-TYPE Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConfigLoadShedTimeOnBattery OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 | INTEGER {upsOutletGroupConfigDisableTimeOnBatteryLoadShed(1), upsOutletGroupConfigEnableTimeOnBatteryLoadShed(2)} | read-write | mandatory |
| upsOutletGroupConfigLoadShedControlRuntimeRemaining OBJECT-TYPE Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShedRuntimeRemaining OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 | INTEGER {upsOutletGroupConfigDisableRuntimeRemainingLoadShed(1), upsOutletGroupConfigEnableRuntimeRemainingLoadShed(2)} | read-write | mandatory |
| upsOutletGroupConfigLoadShedControlInOverload OBJECT-TYPE Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutletGroupConfigLoadShedControlSkipOffDelay is valid for this load shed condition. Returns -1 if not supported by this outlet group. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 | INTEGER {upsOutletGroupConfigDisableInOverloadLoadShed(1), upsOutletGroupConfigEnableInOverloadLoadShed(2)} | read-write | mandatory |
| upsOutletGroupConfigLoadShedTimeOnBattery OBJECT-TYPE When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlTimeOnBattery OID. Allowed values vary by UPS model. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 | INTEGER | read-write | mandatory |
| upsOutletGroupConfigLoadShedRuntimeRemaining OBJECT-TYPE When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlRuntimeRemaining OID. Allowed values vary by UPS model. | 1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 | INTEGER | read-write | mandatory |
| upsOutletGroupControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.12.3 | |||
| upsOutletGroupControlTableSize OBJECT-TYPE The number of outlet groups for the UPS. | 1.3.6.1.4.1.318.1.1.1.12.3.1 | INTEGER | read-only | mandatory |
| upsOutletGroupControlTable OBJECT-TYPE Allows for control of individual outlet groups. The number of entries is contained in the upsOutletGroupControlTableSize OID. | 1.3.6.1.4.1.318.1.1.1.12.3.2 | not-accessible | mandatory | |
| upsOutletGroupControlEntry OBJECT-TYPE The outlet group to control. | 1.3.6.1.4.1.318.1.1.1.12.3.2.1 | not-accessible | mandatory | |
| upsOutletGroupControlIndex OBJECT-TYPE The index to the outlet group entry. | 1.3.6.1.4.1.318.1.1.1.12.3.2.1.1 | INTEGER | read-only | mandatory |
| upsOutletGroupControlName OBJECT-TYPE The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID. | 1.3.6.1.4.1.318.1.1.1.12.3.2.1.2 | DisplayString | read-only | mandatory |
| upsOutletGroupControlCommand OBJECT-TYPE Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupImmediateOn (1) value will be returned. If the outlet group is off, the upsOutletGroupImmediateOff (2) value will be returned. If the state of the outlet group cannot be determined, the upsOutletGroupControlUnknown (8) value will be returned. Setting this variable to upsOutletGroupImmediateOn (1) will turn the outlet group on immediately. Setting this variable to upsOutletGroupImmediateOff (2) will turn the outlet group off immediately. Setting this variable to upsOutletGroupImmediateRebootWithOrWithoutAC (3) will turn the outlet group off immediately, wait the upsOutletGroupConfigRebootDuration OID time, wait the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on regardless of the AC input power on the UPS. Setting this variable to upsOutletGroupDelayedOn (4) will turn the outlet group on after the upsOutletGroupConfigPowerOnDelay OID has elapsed. Setting this variable to upsOutletGroupDelayedOff (5) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed. Setting this variable to upsOutletGroupDelayedRebootWithOrWithoutAC (6) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait the upsOutletGroupConfigRebootDuration OID time, wait the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on regardless of the AC input power on the UPS. Setting this variable to upsOutletGroupCancelPendingCommand (7) will cause any pending command to this outlet group to be canceled. Setting this variable to upsOutletGroupImmediateRebootShutdown (9) will turn the outlet group off immediately, wait for the AC power to return to normal (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet group on. Setting this variable to upsOutletGroupDelayedRebootShutdown (10) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait for the AC power to return to normal (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet group on. In systems with a main outlet group, commands to the main outlet group must be performed with caution. It may be clearer to use the ups control commands available from upsAdvControl... OIDs. If any command is made to the main outlet group that will turn it off, one of two things will happen: 1) If any switched outlet group is in a state that prevents this command from occurring on the main outlet group, the command will be rejected. Note that a switched outlet group being on without a command in progress is not a state that normally prevents the command. 2) The command will be accepted and applied to the main outlet group and all switched outlet groups that are on. There is one additional special case for systems with a main outlet group. If the main outlet group is off and a switched outlet group is commanded to turn on, the on command will be applied to both the main outlet group and that switched outlet group. | 1.3.6.1.4.1.318.1.1.1.12.3.2.1.3 | INTEGER {upsOutletGroupImmediateOn(1), upsOutletGroupImmediateOff(2), upsOutletGroupImmediateRebootWithOrWithoutAC(3), upsOutletGroupDelayedOn(4), upsOutletGroupDelayedOff(5), upsOutletGroupDelayedRebootWithOrWithoutAC(6), upsOutletGroupCancelPendingCommand(7), upsOutletGroupControlUnknown(8), upsOutletGroupImmediateRebootShutdown(9), upsOutletGroupDelayedRebootShutdown(10)} | read-write | mandatory |
| upsOutletGroupControlOutletType OBJECT-TYPE Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail. | 1.3.6.1.4.1.318.1.1.1.12.3.2.1.4 | INTEGER {upsSwitchedOutletGroup(1), upsMainOutletGroup(2)} | read-only | mandatory |
| upsDiagnostics OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13 | |||
| upsDiagnosticIM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.1 | |||
| upsDiagIMTableSize OBJECT-TYPE The number of Intelligence Modules in or attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.1.1 | INTEGER | read-only | mandatory |
| upsDiagIMTable OBJECT-TYPE Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagIMTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.1.2 | not-accessible | mandatory | |
| upsDiagIMEntry OBJECT-TYPE The diagnostics and information of an Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1 | not-accessible | mandatory | |
| upsDiagIMIndex OBJECT-TYPE The index to the Intelligence Module entry. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.1 | INTEGER | read-only | mandatory |
| upsDiagIMType OBJECT-TYPE The type of the Intelligence Module. imUnknown(1) indicates the IM type is unknown. imMIM(2) indicates the IM type is a Main Intelligence Module. imRIM(3) indicates the IM type is Redundant Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.2 | INTEGER {imUnknown(1), imMIM(2), imRIM(3)} | read-only | mandatory |
| upsDiagIMStatus OBJECT-TYPE The status of the Intelligence Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagIMFirmwareRev OBJECT-TYPE The firmware revision of the Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.4 | DisplayString | read-only | mandatory |
| upsDiagIMSlaveFirmwareRev OBJECT-TYPE The slave firmware revision of the Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.5 | DisplayString | read-only | mandatory |
| upsDiagIMHardwareRev OBJECT-TYPE The hardware revision of the Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.6 | DisplayString | read-only | mandatory |
| upsDiagIMSerialNum OBJECT-TYPE The serial number of the Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.7 | DisplayString | read-only | mandatory |
| upsDiagIMManufactureDate OBJECT-TYPE The manufacture date of the Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.8 | DisplayString | read-only | mandatory |
| upsDiagIMInControl OBJECT-TYPE The Intelligence Module state. activeInControl(1) indicates the IM is active and in control. passive(2) indicates the IM is in passive state. unknown(3) indicates the IM is in unknown state. fault(4) indicates the IM is in fault state. | 1.3.6.1.4.1.318.1.1.1.13.1.2.1.9 | INTEGER {activeInControl(1), passive(2), unknown(3), fault(4)} | read-only | mandatory |
| upsDiagnosticPowerModules OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.2 | |||
| upsDiagPMTableSize OBJECT-TYPE The maximum number of Power Modules supported by the UPS. | 1.3.6.1.4.1.318.1.1.1.13.2.1 | INTEGER | read-only | mandatory |
| upsDiagPMTable OBJECT-TYPE Allows for diagnostics of Individual Power modules. The number of entries is contained in the upsDiagPMTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.2.2 | not-accessible | mandatory | |
| upsDiagPMEntry OBJECT-TYPE The diagnostics of an Power Module. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1 | not-accessible | mandatory | |
| upsDiagPMIndex OBJECT-TYPE The index to the Power Module entry. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.1 | INTEGER | read-only | mandatory |
| upsDiagPMStatus OBJECT-TYPE The status of the Power Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.2 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagPMFirmwareRev OBJECT-TYPE The firmware revision of the Power Module. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.3 | DisplayString | read-only | mandatory |
| upsDiagPMHardwareRev OBJECT-TYPE The hardware revision of the Power Module. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.4 | DisplayString | read-only | mandatory |
| upsDiagPMSerialNum OBJECT-TYPE The serial number of the Power Module. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.5 | DisplayString | read-only | mandatory |
| upsDiagPMManufactureDate OBJECT-TYPE The manufacture date of the Power Module. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.6 | DisplayString | read-only | mandatory |
| upsDiagPMModelNum OBJECT-TYPE The model number of the Power Module. | 1.3.6.1.4.1.318.1.1.1.13.2.2.1.7 | DisplayString | read-only | mandatory |
| upsDiagPMLifetimeInfoTable OBJECT-TYPE Allows for diagnostics of individual power module's lifetime information. The number of entries is contained in the upsDiagPMTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.2.3 | not-accessible | mandatory | |
| upsDiagPMLifetimeInfoEntry OBJECT-TYPE The diagnostics of a Power Module lifetime information. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1 | not-accessible | mandatory | |
| upsDiagPMLifetimeInfoIndex OBJECT-TYPE The index to the Power Module lifetime information entry. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.1 | INTEGER | read-only | mandatory |
| upsDiagPMLifetimeStatus OBJECT-TYPE The status of the Power Module lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.2 | INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)} | read-only | mandatory |
| upsDiagPMEstmtdLifetimeRmng OBJECT-TYPE Displays the time remaining for the module before it should be replaced. Measured in months. This value is set when you originally install the module. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.3 | INTEGER | read-only | mandatory |
| upsDiagPMEstmtdLifetimeRmngPct OBJECT-TYPE Displays the percentage of the total lifetime remaining for the module before it should be replaced. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.4 | INTEGER | read-only | mandatory |
| upsDiagPMFanLifetimeStatus OBJECT-TYPE The status of the Power Module Fan lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.5 | INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)} | read-only | mandatory |
| upsDiagPMFanEstmtdLifetimeRmng OBJECT-TYPE Displays the time remaining, measured in months, before the module's fan should be replaced. It is reset by the field service engineer when a new fan is installed. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.6 | INTEGER | read-only | mandatory |
| upsDiagPMFanEstmtdLifetimeRmngPct OBJECT-TYPE Displays the percentage of the total lifetime remaining before the module's fan should be replaced. | 1.3.6.1.4.1.318.1.1.1.13.2.3.1.7 | INTEGER | read-only | mandatory |
| upsDiagPMEnclDoorFltrTableSize OBJECT-TYPE The maximum number of power module enclosures attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.2.4 | INTEGER | read-only | mandatory |
| upsDiagPMEnclDoorFltrTable OBJECT-TYPE Allows for the diagnostics of individual power module enclosure door filters. The number of entries is contained in the upsDiagPMEnclDoorFltrTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.2.5 | not-accessible | mandatory | |
| upsDiagPMEnclDoorFltrEntry OBJECT-TYPE Power module door filter diagnostics info. | 1.3.6.1.4.1.318.1.1.1.13.2.5.1 | not-accessible | mandatory | |
| upsDiagPMEnclIndex OBJECT-TYPE The index to the power module enclosure entry. Enclosure 0 indicates the Power enclosure 1. Enclosure 1 indicates the Power enclosure 2. | 1.3.6.1.4.1.318.1.1.1.13.2.5.1.1 | INTEGER | read-only | mandatory |
| upsDiagPMEnclDoorFltrLifetime OBJECT-TYPE Door filter replacement time interval, based on the installation enivironment. heavyFiltration15days (1) indicates door filter needs to be replaced within 15 days. normalFiltration30days (2) indicates door filter needs to be replaced within 30 days. lightFiltration60days (3) indicates door filter needs to be replaced within 60 days. notPresent(4) indicates that the door filter is not present. | 1.3.6.1.4.1.318.1.1.1.13.2.5.1.2 | INTEGER {heavyFiltration15days(1), normalFiltration30days(2), lightFiltration60days(3), notPresent(4)} | read-only | mandatory |
| upsDiagPMEnclDoorFltrStatus OBJECT-TYPE Indicates the current status of the door filter. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown. | 1.3.6.1.4.1.318.1.1.1.13.2.5.1.3 | INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)} | read-only | mandatory |
| upsDiagPMEnclDoorFltrEstmtdLifetimeRmng OBJECT-TYPE Displays the time remaining, measured in days, before the module door filter should be replaced. This value is set when you originally install the module. | 1.3.6.1.4.1.318.1.1.1.13.2.5.1.4 | INTEGER | read-only | mandatory |
| upsDiagPMEnclDoorFltrEstmtdLifetimeRmngPct OBJECT-TYPE Displays the percentage of the total lifetime remaining for the module door filter before it should be replaced. | 1.3.6.1.4.1.318.1.1.1.13.2.5.1.5 | INTEGER | read-only | mandatory |
| upsDiagnosticBatteries OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.3 | |||
| upsDiagBatteryTableSize OBJECT-TYPE The maximum number of batteries supported by the UPS. | 1.3.6.1.4.1.318.1.1.1.13.3.1 | INTEGER | read-only | mandatory |
| upsDiagBatteryTable OBJECT-TYPE Allows for diagnostics of individual batteries. The number of entries is contained in the upsDiagBattTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.3.2 | not-accessible | mandatory | |
| upsDiagBatteryEntry OBJECT-TYPE The diagnostics of a battery. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1 | not-accessible | mandatory | |
| upsDiagBatteryFrameIndex OBJECT-TYPE The index to the battery frame entry. Frame 0 indicates the Main frame. Extended Run (XR) frames start from index 1. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.1 | INTEGER | read-only | mandatory |
| upsDiagBatteryIndex OBJECT-TYPE The index to the battery entry. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.2 | INTEGER | read-only | mandatory |
| upsDiagBatteryStatus OBJECT-TYPE The status of the battery. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the battery status is OK. failed(4) indicates the battery status is failed. highTemperature(5) indicates the battery has a high temperature condition. replaceImmediately(6) indicates the battery must be replaced immediately. lowCapacity(7) indicates the battery has a low capacity. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.3 | INTEGER {unknown(1), notInstalled(2), ok(3), failed(4), highTemperature(5), replaceImmediately(6), lowCapacity(7)} | read-only | mandatory |
| upsDiagBatterySerialNumber OBJECT-TYPE The serial number of the battery. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.4 | DisplayString | read-only | mandatory |
| upsDiagBatteryFirmwareRev OBJECT-TYPE The firmware revision of the battery. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.5 | DisplayString | read-only | mandatory |
| upsDiagBatteryManufactureDate OBJECT-TYPE The manufacture date of the battery. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.6 | DisplayString | read-only | mandatory |
| upsDiagBatteryType OBJECT-TYPE The battery type or rating for the battery. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.7 | DisplayString | read-only | mandatory |
| upsDiagBatteryFramePresent OBJECT-TYPE The battery frame/cabinet status. 0 indicates frame/cabinet is not present. 1 indicates frame/cabinet is present. | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.8 | INTEGER {notPresent(0), present(1)} | read-only | mandatory |
| upsDiagBatteryFrameTemperature OBJECT-TYPE The battery frame/cabinet temperature in tenths of degrees celsius. If the frame/cabinet is not present, this variable is set to (-1). | 1.3.6.1.4.1.318.1.1.1.13.3.2.1.9 | INTEGER | read-only | mandatory |
| upsDiagBatteryFrameTableSize OBJECT-TYPE The maximum number of battery frames supported by the UPS. | 1.3.6.1.4.1.318.1.1.1.13.3.3 | INTEGER | read-only | mandatory |
| upsDiagBatteryFrameTable OBJECT-TYPE Allows for diagnostics of individual battery frame. The number of entries is contained in the upsDiagBatteryFrameTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.3.4 | not-accessible | mandatory | |
| upsDiagBatteryFrameEntry OBJECT-TYPE The diagnostics of a battery frame. | 1.3.6.1.4.1.318.1.1.1.13.3.4.1 | not-accessible | mandatory | |
| upsDiagBatteryFrameTableIndex OBJECT-TYPE The index to the battery frame entry. | 1.3.6.1.4.1.318.1.1.1.13.3.4.1.1 | INTEGER | read-only | mandatory |
| upsDiagBatteryModuleStatusPerFrame OBJECT-TYPE An ASCII string containing the 64 flags representing the status of battery modules. 1 indicates battery module installed, 0 indicates battery module not installed. The flags are numbered from 1 to 64, and read from left to right. The flags are defined as follows: Flag 1: Battery Module Level 1 A Flag 2: Battery Module Level 1 B Flag 3: Battery Module Level 1 C Flag 4: Battery Module Level 1 D Flag 5: Battery Module Level 1 E Flag 6: Battery Module Level 1 F Flag 7: Battery Module Level 2 A Flag 8: Battery Module Level 2 B Flag 9: Battery Module Level 2 C Flag 10: Battery Module Level 2 D Flag 11: Battery Module Level 2 E Flag 12: Battery Module Level 2 F Flag 13: Battery Module Level 3 A Flag 14: Battery Module Level 3 B Flag 15: Battery Module Level 3 C Flag 16: Battery Module Level 3 D Flag 17: Battery Module Level 3 E Flag 18: Battery Module Level 3 F Flag 19: Battery Module Level 4 A Flag 20: Battery Module Level 4 B Flag 21: Battery Module Level 4 C Flag 22: Battery Module Level 4 D Flag 23: Battery Module Level 4 E Flag 24: Battery Module Level 4 F Flag 25: Battery Module Level 7 A Flag 26: Battery Module Level 7 B Flag 27: Battery Module Level 7 C Flag 28: Battery Module Level 7 D Flag 29: Battery Module Level 7 E Flag 30: Battery Module Level 7 F Flag 31: Battery Module Level 8 A Flag 32: Battery Module Level 8 B Flag 33: Battery Module Level 8 C Flag 34: Battery Module Level 8 D Flag 35: Battery Module Level 8 E Flag 36: Battery Module Level 8 F Flag 37: Battery Module Level 9 A Flag 38: Battery Module Level 9 B Flag 39: Battery Module Level 9 C Flag 40: Battery Module Level 9 D Flag 41: Battery Module Level 9 E Flag 42: Battery Module Level 9 F Flag 43: Battery Module Level 10 A Flag 44: Battery Module Level 10 B Flag 45: Battery Module Level 10 C Flag 46: Battery Module Level 10 D Flag 47: Battery Module Level 10 E Flag 48: Battery Module Level 10 F Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> | 1.3.6.1.4.1.318.1.1.1.13.3.4.1.2 | DisplayString | read-only | mandatory |
| upsDiagBatteryPositiveVoltage OBJECT-TYPE The battery positive voltage, in Volts. | 1.3.6.1.4.1.318.1.1.1.13.3.4.1.3 | INTEGER | read-only | mandatory |
| upsDiagBatteryNegativeVoltage OBJECT-TYPE The battery negative voltage, in Volts. | 1.3.6.1.4.1.318.1.1.1.13.3.4.1.4 | INTEGER | read-only | mandatory |
| upsDiagBatteryTemperature OBJECT-TYPE The battery frame/cabinet temperature in tenths of degrees celsius. If the frame/cabinet is not present, this variable is set to (-1). | 1.3.6.1.4.1.318.1.1.1.13.3.4.1.5 | INTEGER | read-only | mandatory |
| upsDiagnosticSubsystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.4 | |||
| upsDiagSubSysFrameTableSize OBJECT-TYPE The number of frames attached to the UPS including the Main frame. | 1.3.6.1.4.1.318.1.1.1.13.4.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysFrameTable OBJECT-TYPE Allows for diagnostics of individual XR Frames. | 1.3.6.1.4.1.318.1.1.1.13.4.2 | not-accessible | mandatory | |
| upsDiagSubSysFrameEntry OBJECT-TYPE The diagnostics of an XR Frame. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1 | not-accessible | mandatory | |
| upsDiagSubSysFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysFrameType OBJECT-TYPE The type of Frame. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. frameTypeMain(3) indicates the frame type is the Main Frame. frameTypeXR(4) indicates the frame type is an XR Frame. frameTypeLXR(5) indicates the frame type is an LXR Frame. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1.2 | INTEGER {unknown(1), notInstalled(2), frameTypeMain(3), frameTypeXR(4), frameTypeLXR(5)} | read-only | mandatory |
| upsDiagSubSysFrameFirmwareRev OBJECT-TYPE The firmware revision of the frame. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1.3 | DisplayString | read-only | mandatory |
| upsDiagSubSysFrameHardwareRev OBJECT-TYPE The hardware revision of the frame. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysFrameSerialNum OBJECT-TYPE The serial number of the frame. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysFrameManufactureDate OBJECT-TYPE The manufacture date of the frame. | 1.3.6.1.4.1.318.1.1.1.13.4.2.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysIntBypSwitchTableSize OBJECT-TYPE The number of Internal Bypass switches attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.3 | INTEGER | read-only | mandatory |
| upsDiagSubSysIntBypSwitchTable OBJECT-TYPE Allows for diagnostics of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4 | not-accessible | mandatory | |
| upsDiagSubSysIntBypSwitchEntry OBJECT-TYPE The diagnostics of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1 | not-accessible | mandatory | |
| upsDiagSubSysIntBypSwitchFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysIntBypSwitchIndex OBJECT-TYPE The Internal Bypass Switch index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysIntBypSwitchStatus OBJECT-TYPE The Internal Bypass Switch status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysIntBypSwitchFirmwareRev OBJECT-TYPE The firmware revision of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysIntBypSwitchHardwareRev OBJECT-TYPE The hardware revision of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysIntBypSwitchSerialNum OBJECT-TYPE The serial number of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysIntBypSwitchManufactureDate OBJECT-TYPE The manufacture date of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysIntBypSwitchModelNum OBJECT-TYPE The model number of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.4.1.8 | DisplayString | read-only | mandatory |
| upsDiagSubSysBattMonitorTableSize OBJECT-TYPE The number of Battery Monitor Boards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.5 | INTEGER | read-only | mandatory |
| upsDiagSubSysBattMonitorTable OBJECT-TYPE Allows for diagnostics of the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6 | not-accessible | mandatory | |
| upsDiagSubSysBattMonitorEntry OBJECT-TYPE The diagnostics of the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1 | not-accessible | mandatory | |
| upsDiagSubSysBattMonitorFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysBattMonitorIndex OBJECT-TYPE The index of the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysBattMonitorStatus OBJECT-TYPE The status of the Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysBattMonitorFirmwareRev OBJECT-TYPE The firmware revision of the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysBattMonitorHardwareRev OBJECT-TYPE The hardware revision of the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysBattMonitorSerialNum OBJECT-TYPE The serial number of the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysBattMonitorManufactureDate OBJECT-TYPE The date of the manufacture for the Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.6.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearTableSize OBJECT-TYPE The number of External Switch Gears attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.7 | INTEGER | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearTable OBJECT-TYPE Allows for diagnostics of the individual External Switch Gear. | 1.3.6.1.4.1.318.1.1.1.13.4.8 | not-accessible | mandatory | |
| upsDiagSubSysExternalSwitchGearEntry OBJECT-TYPE The diagnostics of an individual External Switch Gear. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1 | not-accessible | mandatory | |
| upsDiagSubSysExternalSwitchGearFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearIndex OBJECT-TYPE The index of the External Switch Gear. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearStatus OBJECT-TYPE The status of the External Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearFirmwareRev OBJECT-TYPE The firmware revision of the External Switch Gear monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearHardwareRev OBJECT-TYPE The hardware revision of the External Switch Gear monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearSerialNum OBJECT-TYPE The serial number of the External Switch Gear monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearManufactureDate OBJECT-TYPE The date of the manufacture for the External Switch Gear monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalSwitchGearTemperature OBJECT-TYPE The temperature of the air around the External Switch Gear monitor card in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.1.13.4.8.1.8 | INTEGER | read-only | mandatory |
| upsDiagSubSysDisplayInterfaceCardTableSize OBJECT-TYPE The number of Display Interface Cards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.9 | INTEGER | read-only | mandatory |
| upsDiagSubSysDisplayInterfaceCardTable OBJECT-TYPE Allows for diagnostics of individual Display Interface Cards. | 1.3.6.1.4.1.318.1.1.1.13.4.10 | not-accessible | mandatory | |
| upsDiagSubSysDisplayInterfaceCardEntry OBJECT-TYPE The diagnostics of a Display Interface Card. | 1.3.6.1.4.1.318.1.1.1.13.4.10.1 | not-accessible | mandatory | |
| upsDiagSubSysDisplayInterfaceCardFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.10.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysDisplayInterfaceCardIndex OBJECT-TYPE The index of the Display Interface Card. | 1.3.6.1.4.1.318.1.1.1.13.4.10.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysDisplayInterfaceCardStatus OBJECT-TYPE The status of the Display Interface Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.10.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysDCCircuitBreakerTableSize OBJECT-TYPE The number of DC Circuit Breakers attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.11 | INTEGER | read-only | mandatory |
| upsDiagSubSysDCCircuitBreakerTable OBJECT-TYPE Allows for diagnostics of individual DC Circuit Breakers. | 1.3.6.1.4.1.318.1.1.1.13.4.12 | not-accessible | mandatory | |
| upsDiagSubSysDCCircuitBreakerEntry OBJECT-TYPE The diagnostics of a DC Circuit Breaker. | 1.3.6.1.4.1.318.1.1.1.13.4.12.1 | not-accessible | mandatory | |
| upsDiagSubSysDCCircuitBreakerFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.12.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysDCCircuitBreakerIndex OBJECT-TYPE The index of the DC Circuit Breaker. | 1.3.6.1.4.1.318.1.1.1.13.4.12.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysDCCircuitBreakerStatus OBJECT-TYPE The status of the DC Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed. | 1.3.6.1.4.1.318.1.1.1.13.4.12.1.3 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyTableSize OBJECT-TYPE The number of System Power Supplies attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.13 | INTEGER | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyTable OBJECT-TYPE Allows for diagnostics of individual System Power Supplies. | 1.3.6.1.4.1.318.1.1.1.13.4.14 | not-accessible | mandatory | |
| upsDiagSubSysSystemPowerSupplyEntry OBJECT-TYPE The diagnostics of a System Power Supply. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1 | not-accessible | mandatory | |
| upsDiagSubSysSystemPowerSupplyFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyIndex OBJECT-TYPE The index of a System Power Supply. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyStatus OBJECT-TYPE The status of the System Power Supply. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyFirmwareRev OBJECT-TYPE The firmware revision of the System Power Supply monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyHardwareRev OBJECT-TYPE The hardware revision of the System Power Supply monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplySerialNum OBJECT-TYPE The serial number of the System Power Supply monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysSystemPowerSupplyManufactureDate OBJECT-TYPE The date of the manufacture for the System Power Supply monitor card. | 1.3.6.1.4.1.318.1.1.1.13.4.14.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysXRCommunicationCardTableSize OBJECT-TYPE The number of XR Communication Cards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.15 | INTEGER | read-only | mandatory |
| upsDiagSubSysXRCommunicationCardTable OBJECT-TYPE Allows for diagnostics of individual XR Communication Cards. | 1.3.6.1.4.1.318.1.1.1.13.4.16 | not-accessible | mandatory | |
| upsDiagSubSysXRCommunicationCardEntry OBJECT-TYPE The diagnostics of an XR Communication Card. | 1.3.6.1.4.1.318.1.1.1.13.4.16.1 | not-accessible | mandatory | |
| upsDiagSubSysXRCommunicationCardFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.16.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysXRCommunicationCardIndex OBJECT-TYPE The index of an XR Communication Card. | 1.3.6.1.4.1.318.1.1.1.13.4.16.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysXRCommunicationCardStatus OBJECT-TYPE The status of the XR Communication Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.16.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysXRCommunicationCardFirmwareRev OBJECT-TYPE The firmware revision of the XR Communication card. | 1.3.6.1.4.1.318.1.1.1.13.4.16.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysXRCommunicationCardSerialNum OBJECT-TYPE The serial number of the XR Communication card. | 1.3.6.1.4.1.318.1.1.1.13.4.16.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalPowerFrameBoardTableSize OBJECT-TYPE The number of External Power Frame Boards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.17 | INTEGER | read-only | mandatory |
| upsDiagSubSysExternalPowerFrameBoardTable OBJECT-TYPE Allows for diagnostics of individual External Power Frame Boards. | 1.3.6.1.4.1.318.1.1.1.13.4.18 | not-accessible | mandatory | |
| upsDiagSubSysExternalPowerFrameBoardEntry OBJECT-TYPE The diagnostics of an External Power Frame Board. | 1.3.6.1.4.1.318.1.1.1.13.4.18.1 | not-accessible | mandatory | |
| upsDiagSubSysExternalPowerFrameBoardFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.18.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysExternalPowerFrameBoardIndex OBJECT-TYPE The index of an External Power Frame Board. | 1.3.6.1.4.1.318.1.1.1.13.4.18.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysExternalPowerFrameBoardStatus OBJECT-TYPE The status of the External Power Frame Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.18.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysChargerTableSize OBJECT-TYPE The number of Chargers attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.19 | INTEGER | read-only | mandatory |
| upsDiagSubSysChargerTable OBJECT-TYPE Allows for diagnostics of individual chargers. | 1.3.6.1.4.1.318.1.1.1.13.4.20 | not-accessible | mandatory | |
| upsDiagSubSysChargerEntry OBJECT-TYPE The diagnostics of a charger. | 1.3.6.1.4.1.318.1.1.1.13.4.20.1 | not-accessible | mandatory | |
| upsDiagSubSysChargerFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.20.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysChargerIndex OBJECT-TYPE The index of a charger. | 1.3.6.1.4.1.318.1.1.1.13.4.20.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysChargerStatus OBJECT-TYPE The status of the Charger. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.20.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysInverterTableSize OBJECT-TYPE The number of Inverters attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.21 | INTEGER | read-only | mandatory |
| upsDiagSubSysInverterTable OBJECT-TYPE Allows for diagnostics of individual Inverters. | 1.3.6.1.4.1.318.1.1.1.13.4.22 | not-accessible | mandatory | |
| upsDiagSubSysInverterEntry OBJECT-TYPE The diagnostics of an Inverter. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1 | not-accessible | mandatory | |
| upsDiagSubSysInverterFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysInverterIndex OBJECT-TYPE The index of an Inverter. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysInverterStatus OBJECT-TYPE The status of the Inverter. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysInverterFirmwareRev OBJECT-TYPE The firmware revision of the Inverter monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysInverterHardwareRev OBJECT-TYPE The hardware revision of the Inverter monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysInverterSerialNum OBJECT-TYPE The serial number of the Inverter monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysInverterManufactureDate OBJECT-TYPE The date of manufacture for the Inverter monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.22.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionTableSize OBJECT-TYPE The number of Power Factor Correction devices attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.23 | INTEGER | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionTable OBJECT-TYPE Allows for diagnostics of individual PowerFactorCorrections. | 1.3.6.1.4.1.318.1.1.1.13.4.24 | not-accessible | mandatory | |
| upsDiagSubSysPowerFactorCorrectionEntry OBJECT-TYPE The diagnostics of a Power Factor Correction. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1 | not-accessible | mandatory | |
| upsDiagSubSysPowerFactorCorrectionFrameIndex OBJECT-TYPE The frame index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionIndex OBJECT-TYPE The index of a Power Factor Correction. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionStatus OBJECT-TYPE The status of the Power Factor Correction. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.3 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionFirmwareRev OBJECT-TYPE The firmware revision of the Power Factor Correction monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionHardwareRev OBJECT-TYPE The hardware revision of the Power Factor Correction monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionSerialNum OBJECT-TYPE The serial number of the Power Factor Correction monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysPowerFactorCorrectionManufactureDate OBJECT-TYPE The date of the manufacture for the Power Factor Correction monitor. | 1.3.6.1.4.1.318.1.1.1.13.4.24.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysNetworkComCardTableSize OBJECT-TYPE The number of Network Communication Cards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.25 | INTEGER | read-only | mandatory |
| upsDiagSubSysNetworkComCardTable OBJECT-TYPE Allows for getting diagnostics information of an individual Network Communication Card. | 1.3.6.1.4.1.318.1.1.1.13.4.26 | not-accessible | mandatory | |
| upsDiagSubSysNetworkComCardEntry OBJECT-TYPE The diagnostics of a Network Communication Card. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1 | not-accessible | mandatory | |
| upsDiagSubSysNetworkComCardIndex OBJECT-TYPE The UPS network and display interface communication card index entry. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysNetworkComCardModelNumber OBJECT-TYPE A character string identifying the model number of the UPS network and display interface communication card. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.2 | DisplayString | read-only | mandatory |
| upsDiagSubSysNetworkComCardSerialNumber OBJECT-TYPE A character string identifying the serial number of the UPS network and display interface communication card. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.3 | DisplayString | read-only | mandatory |
| upsDiagSubSysNetworkComCardDateOfManufacture OBJECT-TYPE The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysNetworkComCardHardwareRev OBJECT-TYPE The hardware revision of the UPS network and display interface communication card. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysNetworkComCardFirmwareAppRev OBJECT-TYPE An ID string identifying the application firmware revision of the UPS network and display interface communication card. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.6 | DisplayString | read-only | mandatory |
| upsDiagSubSysNetworkComCardFirmwareAppOSRev OBJECT-TYPE An ID string identifying the application operating system firmware revision of the UPS network and display interface communication card. | 1.3.6.1.4.1.318.1.1.1.13.4.26.1.7 | DisplayString | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorTableSize OBJECT-TYPE The number of user supplied Battery Monitor Boards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.27 | INTEGER | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorTable OBJECT-TYPE Allows for diagnostics of the user supplied Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.28 | not-accessible | mandatory | |
| upsDiagSubSysUsrSuppBattMonitorEntry OBJECT-TYPE The diagnostics of the user supplied Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1 | not-accessible | mandatory | |
| upsDiagSubSysUsrSuppBattMonitorIndex OBJECT-TYPE The index of the user supplied Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorStatus OBJECT-TYPE The status of the user supplied Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1.2 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorFirmwareRev OBJECT-TYPE The firmware revision of the user supplied Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1.3 | DisplayString | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorHardwareRev OBJECT-TYPE The hardware revision of the user supplied Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorSerialNum OBJECT-TYPE The serial number of the user supplied Battery Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysUsrSuppBattMonitorTemperature OBJECT-TYPE The temperature of the air around the user supplied Battery Monitor Board in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.1.13.4.28.1.6 | INTEGER | read-only | mandatory |
| upsDiagSubSysUsrSuppBattBreakerStatus OBJECT-TYPE The status of the user supplied Battery Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed. | 1.3.6.1.4.1.318.1.1.1.13.4.29 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagSubSysPSUTableSize OBJECT-TYPE The number of Power Supply Units in the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.30 | INTEGER | read-only | mandatory |
| upsDiagSubSysPSUTable OBJECT-TYPE Allows for diagnostics of individual Power Supply Units. The number of entries is contained in the upsDiagSubSysPSUTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.4.31 | not-accessible | mandatory | |
| upsDiagSubSysPSUEntry OBJECT-TYPE The diagnostics information of a Power Supply Unit. | 1.3.6.1.4.1.318.1.1.1.13.4.31.1 | not-accessible | mandatory | |
| upsDiagSubSysPSUIndex OBJECT-TYPE The index to the Power Supply Unit entry. | 1.3.6.1.4.1.318.1.1.1.13.4.31.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysPSUStatus OBJECT-TYPE The status of the Power Supply Unit. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.31.1.2 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysIDRCTableSize OBJECT-TYPE The number of ID and Relay Controller Cards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.32 | INTEGER | read-only | mandatory |
| upsDiagSubSysIDRCTable OBJECT-TYPE Allows for diagnostics of the ID and Relay Controller Card. | 1.3.6.1.4.1.318.1.1.1.13.4.33 | not-accessible | mandatory | |
| upsDiagSubSysIDRCEntry OBJECT-TYPE The diagnostics of the ID and Relay Controller Card. | 1.3.6.1.4.1.318.1.1.1.13.4.33.1 | not-accessible | mandatory | |
| upsDiagSubSysIDRCIndex OBJECT-TYPE The index of the ID and Relay Controller Card. | 1.3.6.1.4.1.318.1.1.1.13.4.33.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysIDRCStatus OBJECT-TYPE The status of the ID and Relay Controller Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.33.1.2 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysIDRCFirmwareRev OBJECT-TYPE The firmware revision of the ID and Relay Controller Card. | 1.3.6.1.4.1.318.1.1.1.13.4.33.1.3 | DisplayString | read-only | mandatory |
| upsDiagSubSysIDRCHardwareRev OBJECT-TYPE The hardware revision of the ID and Relay Controller Card. | 1.3.6.1.4.1.318.1.1.1.13.4.33.1.4 | DisplayString | read-only | mandatory |
| upsDiagSubSysIDRCSerialNum OBJECT-TYPE The serial number of the ID and Relay Controller Card. | 1.3.6.1.4.1.318.1.1.1.13.4.33.1.5 | DisplayString | read-only | mandatory |
| upsDiagSubSysExternalConnectorStatus OBJECT-TYPE The status of the external connector board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.4.34 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagSubSysBackfeedContactorTableSize OBJECT-TYPE The number of backfeed protection contactor attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.35 | INTEGER | read-only | mandatory |
| upsDiagSubSysBackfeedContactorTable OBJECT-TYPE Backfeed protection contactor table. | 1.3.6.1.4.1.318.1.1.1.13.4.36 | not-accessible | mandatory | |
| upsDiagSubSysBackfeedContactorEntry OBJECT-TYPE A list of backfeed protection contactors. | 1.3.6.1.4.1.318.1.1.1.13.4.36.1 | not-accessible | mandatory | |
| upsDiagSubSysbackfeedContactorIndex OBJECT-TYPE The index of the backfeed protection contactor. | 1.3.6.1.4.1.318.1.1.1.13.4.36.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysbackfeedContactorName OBJECT-TYPE The name of the backfeed protection contactor. | 1.3.6.1.4.1.318.1.1.1.13.4.36.1.2 | DisplayString | read-write | mandatory |
| upsDiagSubSysbackfeedContactorType OBJECT-TYPE Indicates the backfeed protection contactor types available in the UPS system. If the UPS is unable to find any attached contactors, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.13.4.36.1.3 | INTEGER {unknown(1), normalAC(2), bypassAC(3)} | read-only | mandatory |
| upsDiagSubSysbackfeedContactorStatus OBJECT-TYPE The status of backfeed protection contactor. unknown(1) indicates the contactor status is unknown. opened (2) indicates the contactor is opened. closed (3) indicates the contactor is closed. | 1.3.6.1.4.1.318.1.1.1.13.4.36.1.4 | INTEGER {unknown(1), opened(2), closed(3)} | read-only | mandatory |
| upsDiagSubSysIntBypSwitchFanLifetimeInfoTableSize OBJECT-TYPE The number of backfeed protection contactor attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.4.37 | INTEGER | read-only | mandatory |
| upsDiagSubSysIntBypSwitchFanLifetimeInfoTable OBJECT-TYPE Allows for diagnostics of the Internal Bypass Switch life time infomation. | 1.3.6.1.4.1.318.1.1.1.13.4.38 | not-accessible | mandatory | |
| upsDiagSubSysIntBypSwitchFanLifetimeInfoEntry OBJECT-TYPE The diagnostics of the Internal Bypass Switch. | 1.3.6.1.4.1.318.1.1.1.13.4.38.1 | not-accessible | mandatory | |
| upsDiagSubSysIntBypSwitchFanLifetimeInfoIndex OBJECT-TYPE The index to the Internal Bypass Switch Fan liftime information entry | 1.3.6.1.4.1.318.1.1.1.13.4.38.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubSysIntBypSwitchFanLifetimeStatus OBJECT-TYPE The status of the Internal Bypass Switch Fan lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown. | 1.3.6.1.4.1.318.1.1.1.13.4.38.1.2 | INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)} | read-only | mandatory |
| upsDiagSubSysIntBypSwitchFanEstmtdLifetimeRmng OBJECT-TYPE Displays the time remaining for the module before it should be replaced. Measured in months. This value is set when you originally install the module. | 1.3.6.1.4.1.318.1.1.1.13.4.38.1.3 | INTEGER | read-only | mandatory |
| upsDiagSubSysIntBypSwitchFanEstmtdLifetimeRmngPct OBJECT-TYPE Displays the percentage of the total lifetime remaining for the module before it should be replaced. | 1.3.6.1.4.1.318.1.1.1.13.4.38.1.4 | INTEGER | read-only | mandatory |
| upsDiagnosticExternalDevices OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.5 | |||
| upsDiagSwitchGear OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.5.1 | |||
| upsDiagSwitchGearStatus OBJECT-TYPE The status of the Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. fail(4) indicates the device status has failed. lostComm(5) indicates the device has lost communication. overtemp(6) indicates the device has an over temperature condition. | 1.3.6.1.4.1.318.1.1.1.13.5.1.1 | INTEGER {unknown(1), notInstalled(2), ok(3), fail(4), lostComm(5), overtemp(6)} | read-only | mandatory |
| upsDiagSwitchGearInputSwitchStatus OBJECT-TYPE The status of the Switch Gear Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.1.2 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagSwitchGearOutputSwitchStatus OBJECT-TYPE The status of the Switch Gear Output Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.1.3 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagSwitchGearBypassSwitchStatus OBJECT-TYPE The status of the Switch Gear Bypass Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.1.4 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagSwitchGearBypassInputSwitchStatus OBJECT-TYPE The status of the Switch Gear Bypass Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.1.5 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagSwitchGearBreakerTableSize OBJECT-TYPE The number of switchgear breakers attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.5.1.6 | INTEGER | read-only | mandatory |
| upsDiagSwitchGearBreakerTable OBJECT-TYPE Switchgear breaker table. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7 | not-accessible | mandatory | |
| upsDiagSwitchGearBreakerEntry OBJECT-TYPE A list of switchgear breakers. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1 | not-accessible | mandatory | |
| switchgearBreakerIndex OBJECT-TYPE The index of the switchgear breaker. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.1 | INTEGER | read-only | mandatory |
| switchgearBreakerPresent OBJECT-TYPE Indicates if the switchgear breaker is present. notPresent(1) indicates that the breaker is not present. present(2) indicates that the breaker is present. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.2 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| switchgearBreakerName OBJECT-TYPE The name of the switchgear breaker. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.3 | DisplayString | read-write | mandatory |
| switchgearBreakerType OBJECT-TYPE Indicates the switchgear breaker types available in the UPS system. If the UPS is unable to find any attached breakers, this variable is set to unknown(1). If the system has multiple breakers of the same type (eg. multiple battery breakers) the status shown in OID switchgearBreakerStatus will be the aggregated status. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.4 | INTEGER {unknown(1), unitInputBreaker(2), staticSwitchInputBreaker(3), maintenanceBypassBreaker(4), unitOutputBreaker(5), systemIsolationBreaker(6), batteryBreaker(7), bypassBackFeedBreaker(8), internalMaintenanceBypassBreaker(9), redundantInternalMaintenanceBypassBreaker(10)} | read-only | mandatory |
| switchgearBreakerStatus OBJECT-TYPE The status of switchgear breaker. unknown(1) indicates the breaker status is unknown. opened (2) indicates the breaker is opened. closed (3) indicates the breaker is closed. NOTE: If there are more than one breaker of the same type, the status reflects the aggregated value. For battery breakers as example, closed would mean that at least one breaker is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.5 | INTEGER {unknown(1), opened(2), closed(3)} | read-only | mandatory |
| upsDiagSubFeedBreakerTableSize OBJECT-TYPE The number of subfeed breakers attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.5.1.8 | INTEGER | read-only | mandatory |
| upsDiagSubFeedBreakerTable OBJECT-TYPE Subfeed breaker table. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9 | not-accessible | mandatory | |
| upsDiagSubFeedBreakerEntry OBJECT-TYPE A list of subfeed breakers. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1 | not-accessible | mandatory | |
| subfeedBreakerIndex OBJECT-TYPE The index of the subfeed breakers. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.1 | INTEGER | read-only | mandatory |
| subfeedBreakerPresent OBJECT-TYPE Indicates if the subfeed breaker is present. notPresent (1) indicates that the breaker is not present. present (2) indicates that the breaker is present. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.2 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| subfeedBreakerRating OBJECT-TYPE The current rating of the installed subfeed breaker. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.3 | INTEGER | read-only | mandatory |
| subfeedBreakerUpperAcceptPowerWarning OBJECT-TYPE The maximum acceptable load before warning is issued. Expressed as percent of the subfeed breaker rating. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.4 | INTEGER (0..100) | read-write | mandatory |
| subfeedBreakerUpperAcceptPowerCritical OBJECT-TYPE The maximum load before a critical alarm occurs. Expressed as percent of the subfeed breaker rating. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.5 | INTEGER (0..125) | read-write | mandatory |
| subfeedBreakerStatus OBJECT-TYPE The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.6 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| subfeedBreakerName OBJECT-TYPE The name of the subfeed breaker. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.7 | DisplayString | read-write | mandatory |
| subfeedBreakerCurrent OBJECT-TYPE The subfeed current in tenths of Amps. | 1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.8 | INTEGER | read-only | mandatory |
| upsDiagSwitchGearInstallationLoadPct OBJECT-TYPE The actual output load expressed as a percentage of the rating of the UPS. | 1.3.6.1.4.1.318.1.1.1.13.5.1.10 | INTEGER | read-only | mandatory |
| upsDiagSubFeedPhaseTable OBJECT-TYPE A list of subfeed phase table. | 1.3.6.1.4.1.318.1.1.1.13.5.1.11 | not-accessible | mandatory | |
| upsDiagSubFeedPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular phase. | 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1 | not-accessible | mandatory | |
| upsDiagSubFeedBreakerIndex OBJECT-TYPE The subfeed breaker index. | 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.1 | INTEGER | read-only | mandatory |
| upsDiagSubFeedPhaseIndex OBJECT-TYPE The subfeed phase index. | 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.2 | INTEGER | read-only | mandatory |
| upsDiagSubFeedPhaseCurrent OBJECT-TYPE The subfeed phase current in Amps. | 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.3 | INTEGER | read-only | mandatory |
| upsDiagSubFeedPhaseCurrentAlternate OBJECT-TYPE The subfeed phase current in tenths of Amps. | 1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.4 | INTEGER | read-only | mandatory |
| upsDiagSwitchgearSerialNumber OBJECT-TYPE The serial number of the UPS I/O Cabinet. | 1.3.6.1.4.1.318.1.1.1.13.5.1.12 | DisplayString | read-only | mandatory |
| upsDiagSwitchgearAmbientTemperature OBJECT-TYPE The ambient temperature of I/O Cabinet in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.1.13.5.1.13 | INTEGER | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorTableSize OBJECT-TYPE The number of user supplied Switch Gear Monitor Boards attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.5.1.14 | INTEGER | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorTable OBJECT-TYPE Allows for diagnostics of the user supplied Switch Gear Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15 | not-accessible | mandatory | |
| upsDiagUsrSuppSwitchgearMonitorEntry OBJECT-TYPE The diagnostics of the user supplied Switch Gear Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1 | not-accessible | mandatory | |
| upsDiagUsrSuppSwitchgearMonitorIndex OBJECT-TYPE The index of the user supplied Switch Gear Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.1 | INTEGER | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorStatus OBJECT-TYPE The status of the user supplied Switch Gear Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.2 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorFirmwareRev OBJECT-TYPE The firmware revision of the user supplied Switch Gear Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.3 | DisplayString | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorHardwareRev OBJECT-TYPE The hardware revision of the user supplied Switch Gear Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.4 | DisplayString | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorSerialNum OBJECT-TYPE The serial number of the user supplied Switch Gear Monitor Board. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.5 | DisplayString | read-only | mandatory |
| upsDiagUsrSuppSwitchgearMonitorTemperature OBJECT-TYPE The temperature of the air around the user supplied Switch Gear Monitor Board in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.6 | INTEGER | read-only | mandatory |
| upsDiagMCCBBox OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.5.2 | |||
| upsDiagMCCBBoxStatus OBJECT-TYPE The status of the MCCB Box (Molded Case Circuit Breaker Box) external device. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. opened(3) indicates the circuit is opened. closed(4) indicates the circuit is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.2.1 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsDiagTransformer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.5.3 | |||
| upsDiagTransformerStatus OBJECT-TYPE The status of the External Transformer. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. fail(4) indicates the device status has failed. lostComm(5) indicates the device has lost communication. overtemp(6) indicates the device has an over temperature condition. opened(7) indicates the circuit is opened. closed(8) indicates the circuit is closed. | 1.3.6.1.4.1.318.1.1.1.13.5.3.1 | INTEGER {unknown(1), notInstalled(2), ok(3), fail(4), lostComm(5), overtemp(6), opened(7), closed(8)} | read-only | mandatory |
| upsDiagFlyWheel OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.5.4 | |||
| upsDiagFlyWheelStatus OBJECT-TYPE Indicates the status of flywheel connected to UPS. If the UPS is unable to determine the state of flywheel, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.13.5.4.1 | INTEGER {unknown(1), present(2), notPresent(3)} | read-only | mandatory |
| upsDiagnosticComBus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.6 | |||
| upsDiagComBusInternalMIMStatus OBJECT-TYPE The status of the internal MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure. | 1.3.6.1.4.1.318.1.1.1.13.6.1 | INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)} | read-only | mandatory |
| upsDiagComBusInternalRIMStatus OBJECT-TYPE The status of the internal RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure. | 1.3.6.1.4.1.318.1.1.1.13.6.2 | INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)} | read-only | mandatory |
| upsDiagComBusMIMtoRIMStatus OBJECT-TYPE The status of the MIM to RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure. | 1.3.6.1.4.1.318.1.1.1.13.6.3 | INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)} | read-only | mandatory |
| upsDiagComBusExternalMIMStatus OBJECT-TYPE The status of the external MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure. | 1.3.6.1.4.1.318.1.1.1.13.6.4 | INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)} | read-only | mandatory |
| upsDiagComBusExternalRIMStatus OBJECT-TYPE The status of the external RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure. | 1.3.6.1.4.1.318.1.1.1.13.6.5 | INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)} | read-only | mandatory |
| upsDiagnosticPowerCabinet OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.7 | |||
| upsDiagnosticPowerCabinetTableSize OBJECT-TYPE The maximum number of Power Cabinets supported by the UPS. | 1.3.6.1.4.1.318.1.1.1.13.7.1 | INTEGER | read-only | mandatory |
| upsDiagnosticPowerCabinetTable OBJECT-TYPE Allows for diagnostics of individual Power Cabinets. The number of entries is contained in the upsDiagnosticPowerCabinetTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.7.2 | not-accessible | mandatory | |
| upsDiagnosticPowerCabinetEntry OBJECT-TYPE The diagnostics of a Power Cabinet. | 1.3.6.1.4.1.318.1.1.1.13.7.2.1 | not-accessible | mandatory | |
| upsDiagnosticPowerCabinetIndex OBJECT-TYPE The index to the Power Cabinet. | 1.3.6.1.4.1.318.1.1.1.13.7.2.1.1 | INTEGER | read-only | mandatory |
| upsDiagnosticPowerCabinetAmbientTemperature OBJECT-TYPE The ambient temperature of Power Cabinet in tenths of degrees Celsius. If the Power Cabinet is not present, this variable is set to (-1). | 1.3.6.1.4.1.318.1.1.1.13.7.2.1.2 | INTEGER | read-only | mandatory |
| upsDiagnosticDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.8 | |||
| upsDiagnosticDisplayHardwareRev OBJECT-TYPE The hardware revision of the Display. | 1.3.6.1.4.1.318.1.1.1.13.8.1 | DisplayString | read-only | mandatory |
| upsDiagnosticDisplaySerialNum OBJECT-TYPE The serial number of the Display. | 1.3.6.1.4.1.318.1.1.1.13.8.2 | DisplayString | read-only | mandatory |
| upsDiagnosticDisplayFirmwareRev OBJECT-TYPE The firmware revision of the Display. | 1.3.6.1.4.1.318.1.1.1.13.8.3 | DisplayString | read-only | mandatory |
| upsDiagnosticDisplayModelNum OBJECT-TYPE The model number of the Display. | 1.3.6.1.4.1.318.1.1.1.13.8.4 | DisplayString | read-only | mandatory |
| upsDiagnosticDisplayStatus OBJECT-TYPE The System Level Controller Status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.8.5 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagnosticUnitController OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.9 | |||
| upsDiagUnitControllerTableSize OBJECT-TYPE The number of Unit Controllers in or attached to the UPS. | 1.3.6.1.4.1.318.1.1.1.13.9.1 | INTEGER | read-only | mandatory |
| upsDiagUnitControllerTable OBJECT-TYPE Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagUnitControllerTableSize OID. | 1.3.6.1.4.1.318.1.1.1.13.9.2 | not-accessible | mandatory | |
| upsDiagUnitControllerEntry OBJECT-TYPE The diagnostics and information of an Intelligence Module. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1 | not-accessible | mandatory | |
| upsDiagUnitControllerIndex OBJECT-TYPE The index to the Unit Controller entry. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1.1 | INTEGER | read-only | mandatory |
| upsDiagUnitControllerStatus OBJECT-TYPE The status of the Unit Controller. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1.2 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagUnitControllerFirmwareRev OBJECT-TYPE The firmware revision of the Unit Controller. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1.3 | DisplayString | read-only | mandatory |
| upsDiagUnitControllerHardwareRev OBJECT-TYPE The hardware revision of the Unit Controller. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1.4 | DisplayString | read-only | mandatory |
| upsDiagUnitControllerSerialNum OBJECT-TYPE The serial number of the Unit Controller. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1.5 | DisplayString | read-only | mandatory |
| upsDiagUnitControllerModelNum OBJECT-TYPE The model number of the Unit Controller. | 1.3.6.1.4.1.318.1.1.1.13.9.2.1.6 | DisplayString | read-only | mandatory |
| upsDiagnosticSLC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.10 | |||
| upsDiagnosticSLCHardwareRev OBJECT-TYPE The hardware revision of the System Level Controller. | 1.3.6.1.4.1.318.1.1.1.13.10.1 | DisplayString | read-only | mandatory |
| upsDiagnosticSLCSerialNum OBJECT-TYPE The serial number of the System Level Controller. | 1.3.6.1.4.1.318.1.1.1.13.10.2 | DisplayString | read-only | mandatory |
| upsDiagnosticSLCFirmwareRev OBJECT-TYPE The firmware revision of the System Level Controller. | 1.3.6.1.4.1.318.1.1.1.13.10.3 | DisplayString | read-only | mandatory |
| upsDiagnosticSLCModelNumber OBJECT-TYPE The Model number of the System Level Controller. | 1.3.6.1.4.1.318.1.1.1.13.10.4 | DisplayString | read-only | mandatory |
| upsDiagSLCStatus OBJECT-TYPE The System Level Controller Status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication. | 1.3.6.1.4.1.318.1.1.1.13.10.5 | INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)} | read-only | mandatory |
| upsDiagnosticTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.13.11 | |||
| upsDiagnosticTemperatureAmbientTemperature OBJECT-TYPE The ambient temperature in tenths of degrees Celsius. If not available, this variable is set to (-1999). | 1.3.6.1.4.1.318.1.1.1.13.11.1 | INTEGER | read-only | mandatory |
| upsParallelSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.14 | |||
| upsParallelSysLocalAddress OBJECT-TYPE Defines the UPS ID number in the parallel system. | 1.3.6.1.4.1.318.1.1.1.14.1 | INTEGER | read-write | mandatory |
| upsParallelSysRemoteAddress OBJECT-TYPE Defines the total number of UPSs in parallel. | 1.3.6.1.4.1.318.1.1.1.14.2 | INTEGER | read-write | mandatory |
| upsParallelSysRedundancy OBJECT-TYPE The redundancy warning level for paralleled UPS nplus0 (1) indicates that there are no redundant units. nplus1 (2) indicates that there is one redundant unit. nplus2 (3) indicates that there are two redundant units. nplus3 (4) indicates that there are three redundant units. nplus4 (5) indicates that there are four redundant unit. nplus5 (6) indicates that there are five redundant units. | 1.3.6.1.4.1.318.1.1.1.14.3 | INTEGER {nplus0(1), nplus1(2), nplus2(3), nplus3(4), nplus4(5), nplus5(6)} | read-write | mandatory |
| upsParallelInputMaximumCurrent OBJECT-TYPE Maximum input RMS current of the parallel system measured in Amperes. | 1.3.6.1.4.1.318.1.1.1.14.4 | INTEGER | read-only | mandatory |
| upsParallelTotalOutputPower OBJECT-TYPE The Total Output power of UPS in kW when UPS are configured in parallel or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.5 | INTEGER | read-only | mandatory |
| upsParallelTotalOutputApparentPower OBJECT-TYPE The Total Output Apparent power of UPS in kVA when UPS are configured in parallel or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.6 | INTEGER | read-only | mandatory |
| upsParallelInputPhaseTable OBJECT-TYPE A list of input table entries. | 1.3.6.1.4.1.318.1.1.1.14.7 | not-accessible | mandatory | |
| upsParallelInputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input phase. | 1.3.6.1.4.1.318.1.1.1.14.7.1 | not-accessible | mandatory | |
| upsParallelInputPhaseTableIndex OBJECT-TYPE The parallel unit identifier. | 1.3.6.1.4.1.318.1.1.1.14.7.1.1 | INTEGER | read-only | mandatory |
| upsParallelInputPhaseIndex OBJECT-TYPE The input phase identifier. | 1.3.6.1.4.1.318.1.1.1.14.7.1.2 | INTEGER | read-only | mandatory |
| upsParallelInputCurrent OBJECT-TYPE The input current in amperes, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.7.1.3 | INTEGER | read-only | mandatory |
| upsParallelInputActivePower OBJECT-TYPE The input power in kW, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.7.1.4 | INTEGER | read-only | mandatory |
| upsParallelInputApparentPower OBJECT-TYPE The input apparent power in kVA, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.7.1.5 | INTEGER | read-only | mandatory |
| upsParallelInputVoltage OBJECT-TYPE The input voltage of UPS in volts, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.7.1.6 | INTEGER | read-only | mandatory |
| upsParallelInputMaxVoltage OBJECT-TYPE The peak input voltage in VAC measured since the last reset, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.7.1.7 | INTEGER | read-only | mandatory |
| upsParallelInputMaxCurrent OBJECT-TYPE The peak input current in amperes measured since last reset, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.7.1.8 | INTEGER | read-only | mandatory |
| upsParallelInputTotalActivePower OBJECT-TYPE Total active input power of the parallel system in kW. | 1.3.6.1.4.1.318.1.1.1.14.7.1.9 | INTEGER | read-only | mandatory |
| upsParallelInputTotalApparentPower OBJECT-TYPE Total apparent input power of the parallel system in kVA. | 1.3.6.1.4.1.318.1.1.1.14.7.1.10 | INTEGER | read-only | mandatory |
| upsParallelOutputPhaseTable OBJECT-TYPE A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases. | 1.3.6.1.4.1.318.1.1.1.14.8 | not-accessible | mandatory | |
| upsParallelOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular output phase. | 1.3.6.1.4.1.318.1.1.1.14.8.1 | not-accessible | mandatory | |
| upsParallelOutputPhaseTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.1.14.8.1.1 | INTEGER | read-only | mandatory |
| upsParallelOutputPhaseIndex OBJECT-TYPE The output phase identifier. | 1.3.6.1.4.1.318.1.1.1.14.8.1.2 | INTEGER | read-only | mandatory |
| upsParallelOutputCurrent OBJECT-TYPE The output current in amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.8.1.3 | INTEGER | read-only | mandatory |
| upsParallelOutputLoad OBJECT-TYPE The output load in VA, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.8.1.4 | INTEGER | read-only | mandatory |
| upsParallelOutputPercentLoad OBJECT-TYPE The percentage of the UPS load capacity in VA at present redundancy being used on this output phase, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.8.1.5 | INTEGER | read-only | mandatory |
| upsParallelOutputPower OBJECT-TYPE The output power in Watts, or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.8.1.6 | INTEGER | read-only | mandatory |
| upsParallelOutputApparentPowerTable OBJECT-TYPE A list of output table entries. The number of entries is given by the value of upsOutputNumPhases. | 1.3.6.1.4.1.318.1.1.1.14.9 | not-accessible | mandatory | |
| upsParallelOutputApparentPowerEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.1.14.9.1 | not-accessible | mandatory | |
| upsParallelOutputApparentPowerTableIndex OBJECT-TYPE The UPS parallel output identifier. | 1.3.6.1.4.1.318.1.1.1.14.9.1.1 | INTEGER | read-only | mandatory |
| upsParallelOutputApparentPower OBJECT-TYPE The apparent power of each of UPS in kVA when UPS are configured in parallel. | 1.3.6.1.4.1.318.1.1.1.14.9.1.2 | INTEGER | read-only | mandatory |
| upsParallelDiagSubSysBreakerTable OBJECT-TYPE Allows for diagnostics of parallel Circuit Breakers. | 1.3.6.1.4.1.318.1.1.1.14.10 | not-accessible | mandatory | |
| upsParallelDiagSubSysBreakerEntry OBJECT-TYPE The diagnostics of Circuit Breaker. | 1.3.6.1.4.1.318.1.1.1.14.10.1 | not-accessible | mandatory | |
| upsParallelDiagSubSysBreakerFrameIndex OBJECT-TYPE The Parallel UPS index entry. | 1.3.6.1.4.1.318.1.1.1.14.10.1.1 | INTEGER | read-only | mandatory |
| upsParallelDiagSubSysBreakerIndex OBJECT-TYPE The index of the Circuit Breaker. | 1.3.6.1.4.1.318.1.1.1.14.10.1.2 | INTEGER | read-only | mandatory |
| upsParallelDiagSubSysBreakerStatus OBJECT-TYPE The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed. | 1.3.6.1.4.1.318.1.1.1.14.10.1.3 | INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)} | read-only | mandatory |
| upsParallelDiagSubSysBreakerName OBJECT-TYPE The name of Circuit Breaker. | 1.3.6.1.4.1.318.1.1.1.14.10.1.4 | DisplayString | read-only | mandatory |
| upsParallelOutputTotalPercentLoad OBJECT-TYPE The percentage of the UPS total load capacity in kVA or -1 if it's unsupported by this UPS. | 1.3.6.1.4.1.318.1.1.1.14.11 | INTEGER | read-only | mandatory |
| upsParallelOutputActivePowerTable OBJECT-TYPE A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress. | 1.3.6.1.4.1.318.1.1.1.14.12 | not-accessible | mandatory | |
| upsParallelOutputActivePowerEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.1.14.12.1 | not-accessible | mandatory | |
| upsParallelOutputActivePowerTableIndex OBJECT-TYPE The UPS parallel output identifier. | 1.3.6.1.4.1.318.1.1.1.14.12.1.1 | INTEGER | read-only | mandatory |
| upsParallelOutputActivePower OBJECT-TYPE The active power of each UPS in kW when UPSs are configured in parallel. | 1.3.6.1.4.1.318.1.1.1.14.12.1.2 | INTEGER | read-only | mandatory |
| upsParallelSysSwitchGearInstallationLoadPct OBJECT-TYPE The actual output load expressed as a percentage of the rating of the Parallel UPS system. | 1.3.6.1.4.1.318.1.1.1.14.13 | INTEGER | read-only | mandatory |
| upsParallelSysRedundancyStatus OBJECT-TYPE Displays the number of backup or redundant UPSs set up on the parallel system. nplus0 (1) no redundant units. nplus1 (2) one redundant unit. nplus2 (3) two redundant units. nplus3 (4) three redundant units. nplus4 (5) four redundant units. nplus5 (6) five redundant units. | 1.3.6.1.4.1.318.1.1.1.14.14 | INTEGER {nplus0(1), nplus1(2), nplus2(3), nplus3(4), nplus4(5), nplus5(6)} | read-only | mandatory |
| upsParallelSysName OBJECT-TYPE An ID string for the group of UPS units in the same parallel system. Some products do not allow write operations for this OID. | 1.3.6.1.4.1.318.1.1.1.14.15 | DisplayString | read-write | mandatory |
| upsParallelSysUpsTableSize OBJECT-TYPE The number of UPSs in parallel. | 1.3.6.1.4.1.318.1.1.1.14.16 | INTEGER | read-only | mandatory |
| upsParallelSysUpsTable OBJECT-TYPE A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize. | 1.3.6.1.4.1.318.1.1.1.14.17 | not-accessible | mandatory | |
| upsParallelSysUpsEntry OBJECT-TYPE An entry containing information applicable to a particular UPS in parallel. | 1.3.6.1.4.1.318.1.1.1.14.17.1 | not-accessible | mandatory | |
| upsParallelSysUpsIndex OBJECT-TYPE The index to the Parallel System UPS table entry. | 1.3.6.1.4.1.318.1.1.1.14.17.1.1 | INTEGER | read-only | mandatory |
| upsParallelSysUpsName OBJECT-TYPE The UPS id as assigned by the system. | 1.3.6.1.4.1.318.1.1.1.14.17.1.2 | DisplayString | read-only | mandatory |
| upsParallelSysUpsAlarmStatus OBJECT-TYPE The alarm status of the UPS. unknown(1) indicates the UPS status is unknown. normal(2) indicates UPS is functioning normally. informational(3) indicates informational alarm present in the UPS. warning(4) indicates warning alarm present in the UPS. critical(5) indicates critical alarm present in the UPS. | 1.3.6.1.4.1.318.1.1.1.14.17.1.3 | INTEGER {unknown(1), normal(2), informational(3), warning(4), critical(5)} | read-only | mandatory |
| upsParallelSysUpsMode OBJECT-TYPE The current operating mode of the UPS. If the UPS is unable to determine the state of the UPS, this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.1.14.17.1.4 | INTEGER {unknown(1), onLine(2), onBattery(3), onBatteryTest(4), requestedStaticBypass(5), forcedBypass(6), maintenanceBypass(7), off(8), ecoMode(9), hotStandby(10), inquiring(11)} | read-only | mandatory |
| upsParallelSysUpsSerialNumber OBJECT-TYPE The Serial number of the UPS in parallel. Equivalent to OID 1.3.6.1.4.1.318.1.1.1.1.2.3 (upsAdvIdentSerialNumber). | 1.3.6.1.4.1.318.1.1.1.14.17.1.5 | DisplayString | read-only | mandatory |
| upsParallelNumOfUpsPoweringLoad OBJECT-TYPE Number of UPS powered and protecting the load which are not defective (no battery fault, no internal fault). | 1.3.6.1.4.1.318.1.1.1.14.18 | INTEGER | read-only | mandatory |
| upsParallelMinNumOfRequiredUps OBJECT-TYPE Minimal number of UPS required to guarantee the availability of power. | 1.3.6.1.4.1.318.1.1.1.14.19 | INTEGER | read-only | mandatory |
| upsPhysicalLayout OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.15 | |||
| upsIOFrameLayoutPositionID OBJECT-TYPE Defines the position ID of UPS frame. | 1.3.6.1.4.1.318.1.1.1.15.1 | INTEGER | read-only | mandatory |
| upsBottomFeedFrameLayoutPositionID OBJECT-TYPE Defines the position ID of bottom feed frame. | 1.3.6.1.4.1.318.1.1.1.15.2 | INTEGER | read-only | mandatory |
| upsSwitchGearLayoutPositionID OBJECT-TYPE Defines the position ID of switchgear. | 1.3.6.1.4.1.318.1.1.1.15.3 | INTEGER | read-only | mandatory |
| upsBatteryFrameLayoutTableSize OBJECT-TYPE The number of battery frames. | 1.3.6.1.4.1.318.1.1.1.15.4 | INTEGER | read-only | mandatory |
| upsBatteryFrameLayoutTable OBJECT-TYPE Battery frame layout position ID table. | 1.3.6.1.4.1.318.1.1.1.15.5 | not-accessible | mandatory | |
| upsBatteryFrameLayoutEntry OBJECT-TYPE A list of layout position IDs of battery frames. | 1.3.6.1.4.1.318.1.1.1.15.5.1 | not-accessible | mandatory | |
| batteryFrameIndex OBJECT-TYPE The index of the battery frame. | 1.3.6.1.4.1.318.1.1.1.15.5.1.1 | INTEGER | read-only | mandatory |
| batteryFramePositionID OBJECT-TYPE Defines the position ID of each of the battery frames in the row. | 1.3.6.1.4.1.318.1.1.1.15.5.1.2 | INTEGER | read-only | mandatory |
| upsSideCarFrameLayoutTableSize OBJECT-TYPE The number of sidecar frames. | 1.3.6.1.4.1.318.1.1.1.15.6 | INTEGER | read-only | mandatory |
| upsSideCarFrameLayoutTable OBJECT-TYPE Sidecar frame layout position ID table. | 1.3.6.1.4.1.318.1.1.1.15.7 | not-accessible | mandatory | |
| upsSideCarFrameLayoutEntry OBJECT-TYPE A list of sidecar frame layout position IDs. | 1.3.6.1.4.1.318.1.1.1.15.7.1 | not-accessible | mandatory | |
| sideCarFrameIndex OBJECT-TYPE The index of the sidecar frame. | 1.3.6.1.4.1.318.1.1.1.15.7.1.1 | INTEGER | read-only | mandatory |
| sideCarFramePositionID OBJECT-TYPE Defines the position ID of each of the sidecar frames in the row. | 1.3.6.1.4.1.318.1.1.1.15.7.1.2 | INTEGER | read-only | mandatory |
| upsPowerFrameLayoutTableSize OBJECT-TYPE The number of power frames. | 1.3.6.1.4.1.318.1.1.1.15.8 | INTEGER | read-only | mandatory |
| upsPowerFrameLayoutTable OBJECT-TYPE Power frame layout position ID table. | 1.3.6.1.4.1.318.1.1.1.15.9 | not-accessible | mandatory | |
| upsPowerFrameLayoutEntry OBJECT-TYPE A list of power frame layout position IDs. | 1.3.6.1.4.1.318.1.1.1.15.9.1 | not-accessible | mandatory | |
| powerFrameIndex OBJECT-TYPE The index of the power frame. | 1.3.6.1.4.1.318.1.1.1.15.9.1.1 | INTEGER | read-only | mandatory |
| powerFramePositionID OBJECT-TYPE Defines the position ID of each of the power frames in the row. | 1.3.6.1.4.1.318.1.1.1.15.9.1.2 | INTEGER | read-only | mandatory |
| upsIntegratedATS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.16 | |||
| upsIntegratedATSSelectedSource OBJECT-TYPE The source which is currently selected by the ATS to supply the UPS. | 1.3.6.1.4.1.318.1.1.1.16.1 | INTEGER {noSourceSelected(1), unknown(2), sourceA(3), sourceB(4)} | read-only | mandatory |
| upsIntegratedATSPreferredSource OBJECT-TYPE The preferred source of power when both sources are OK. | 1.3.6.1.4.1.318.1.1.1.16.2 | INTEGER {upsIntegratedATSNoSourcePreference(1), upsIntegratedATSPreferSourceA(2), upsIntegratedATSPreferSourceB(3)} | read-write | mandatory |
| upsIntegratedATSUpsReturnStaggering OBJECT-TYPE This is a delay factor applied to the retransfer of this UPS with integrated ATS. When multiple UPSs are in use from a single source, each UPS can have a unique delay value, which will reduce inrush by preventing all UPSs from transferring at the same time. | 1.3.6.1.4.1.318.1.1.1.16.3 | INTEGER | read-write | mandatory |
| upsIntegratedATSSourceTableSize OBJECT-TYPE The number of input sources for this integrated ATS. | 1.3.6.1.4.1.318.1.1.1.16.4 | INTEGER | read-only | mandatory |
| upsIntegratedATSSourceTable OBJECT-TYPE Allows for getting status and settings for the ATS input sources. The number of entries is contained in the upsIntegratedATSSourceTableSize OID. | 1.3.6.1.4.1.318.1.1.1.16.5 | not-accessible | mandatory | |
| upsIntegratedATSSourceEntry OBJECT-TYPE The input source status to get. | 1.3.6.1.4.1.318.1.1.1.16.5.1 | not-accessible | mandatory | |
| upsIntegratedATSSourceIndex OBJECT-TYPE The index to the input source entry. | 1.3.6.1.4.1.318.1.1.1.16.5.1.1 | INTEGER | read-only | mandatory |
| upsIntegratedATSSourceName OBJECT-TYPE The name of the input source. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.1.16.5.1.2 | DisplayString | read-only | mandatory |
| upsIntegratedATSSourceStatus OBJECT-TYPE Getting this variable will return the input source status. | 1.3.6.1.4.1.318.1.1.1.16.5.1.3 | INTEGER {upsIntegratedATSSourceGood(1), upsIntegratedATSSourceBad(2), upsIntegratedATSSourceUnknown(3)} | read-only | mandatory |
| upsIntegratedATSLineFailDelay OBJECT-TYPE The delay between a selected input source becoming bad, and the ATS switching away from that source. This delay is used to make sure that the line has truly failed before the ATS will be switched. Specified in seconds. | 1.3.6.1.4.1.318.1.1.1.16.5.1.4 | INTEGER | read-write | mandatory |
| upsIntegratedATSLineStabilityDelay OBJECT-TYPE The delay between an unselected input source becoming good, and the ATS switching to that source. This delay is used to make sure that the line has truly returned before the ATS will be switched. Specified in seconds. | 1.3.6.1.4.1.318.1.1.1.16.5.1.5 | INTEGER | read-write | mandatory |
| upsDCOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.17 | |||
| upsDCOutputStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.17.1 | |||
| upsDCOutputStatusTableSize OBJECT-TYPE The number of DC outputs on the UPS. | 1.3.6.1.4.1.318.1.1.1.17.1.1 | INTEGER | read-only | mandatory |
| upsDCOutputStatusTable OBJECT-TYPE Provides status information on UPS DC outputs. The number of entries is contained in the upsDCOutputStatusTableSize OID. | 1.3.6.1.4.1.318.1.1.1.17.1.2 | not-accessible | mandatory | |
| upsDCOutputStatusEntry OBJECT-TYPE The DC output. | 1.3.6.1.4.1.318.1.1.1.17.1.2.1 | not-accessible | mandatory | |
| upsDCOutputStatusTableIndex OBJECT-TYPE The index to the DC output status entry. | 1.3.6.1.4.1.318.1.1.1.17.1.2.1.1 | INTEGER | read-only | mandatory |
| upsDCOutputStatusVoltageNominal OBJECT-TYPE The desired voltage for this output in tenths of VDC. When the output is on and there are no fault conditions, the actual voltage should be near the nominal. | 1.3.6.1.4.1.318.1.1.1.17.1.2.1.2 | INTEGER | read-only | mandatory |
| upsDCOutputStatusCurrentRating OBJECT-TYPE The amount of current this output is able to supply in tenths of amperes. | 1.3.6.1.4.1.318.1.1.1.17.1.2.1.3 | INTEGER | read-only | mandatory |
| upsDCOutputStatusVoltage OBJECT-TYPE The voltage measured on this output in tenths of VDC. | 1.3.6.1.4.1.318.1.1.1.17.1.2.1.4 | INTEGER | read-only | mandatory |
| upsDCOutputStatusCurrent OBJECT-TYPE The current drawn by the load measured on this output in tenths of amperes. | 1.3.6.1.4.1.318.1.1.1.17.1.2.1.5 | INTEGER | read-only | mandatory |
| upsDCOutputStatusAbnormalConditions OBJECT-TYPE An ASCII string containing flags representing active output faults. If the Network Card is unable to determine the state of the faults, this variable is set to 'UNKNOWN'. The flags are numbered 1 onward, read from left to right. The flags are defined as follows starting from 1: Flag 1: Output Overload Flag 2: Output Short Circuit Flag 3: Output Over Voltage Flag 4: <Not Used> Flag 5: Overtemperature Flag 6: Backfeed Relay Fault Flag 7: <Not Used> Flag 8: PFC Input Relay Fault Flag 9: <Not Used> Flag 10: Bypass Relay Fault Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used> Flag 17: <Not Used> Flag 18: <Not Used> Flag 19: Output Fault (over or undervoltage) Flag 20: Bus Converter Fault Flag 21: Sensor Fault Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> | 1.3.6.1.4.1.318.1.1.1.17.1.2.1.6 | DisplayString | read-only | mandatory |
| upsIntegratedUIO OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.18 | |||
| upsOutputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.18.1 | |||
| upsOutputRelayStatusTableSize OBJECT-TYPE The number of integrated output relays on the UPS. | 1.3.6.1.4.1.318.1.1.1.18.1.1 | INTEGER | read-only | mandatory |
| upsOutputRelayStatusTable OBJECT-TYPE Allows for access of individual relays. | 1.3.6.1.4.1.318.1.1.1.18.1.2 | not-accessible | mandatory | |
| upsOutputRelayStatusEntry OBJECT-TYPE The output relays to access. | 1.3.6.1.4.1.318.1.1.1.18.1.2.1 | not-accessible | mandatory | |
| upsOutputRelayIndex OBJECT-TYPE The index to the output relay entry. | 1.3.6.1.4.1.318.1.1.1.18.1.2.1.1 | INTEGER | read-only | mandatory |
| upsOutputRelayState OBJECT-TYPE Getting this variable will return the output relay state. 1 - normal state 2 - abnormal state | 1.3.6.1.4.1.318.1.1.1.18.1.2.1.2 | INTEGER {outputRelayNormalState(1), outputRelayAbnormalState(2)} | read-only | mandatory |
| upsOutputRelayDetailedStatus OBJECT-TYPE An ASCII string containing the 16 flags representing the status of the output relay. The flags are numbered from 1 to 16, and read from left to right. The bits are defined as follows: Flag 1: Cause is true which makes the output relay active if not pending a condition Flag 2: Pending delay Flag 3: Pending peak period Flag 4: <Not Used> Flag 5: <Not Used> Flag 6: <Not Used> Flag 7: <Not Used> Flag 8: <Not Used> Flag 9: <Not Used> Flag 10: <Not Used> Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used> | 1.3.6.1.4.1.318.1.1.1.18.1.2.1.3 | DisplayString | read-only | mandatory |
| upsOutputRelayConfigTableSize OBJECT-TYPE The number of integrated output relays on the UPS. | 1.3.6.1.4.1.318.1.1.1.18.1.3 | INTEGER | read-only | mandatory |
| upsOutputRelayConfigTable OBJECT-TYPE Allows for access of individual relays. | 1.3.6.1.4.1.318.1.1.1.18.1.4 | not-accessible | mandatory | |
| upsOutputRelayConfigEntry OBJECT-TYPE The output relays to access. | 1.3.6.1.4.1.318.1.1.1.18.1.4.1 | not-accessible | mandatory | |
| upsOutputRelayConfigIndex OBJECT-TYPE The index to the output relay entry. | 1.3.6.1.4.1.318.1.1.1.18.1.4.1.1 | INTEGER | read-only | mandatory |
| upsOutputRelayConfigDelay OBJECT-TYPE Output relay delay 0 - 86400 seconds. | 1.3.6.1.4.1.318.1.1.1.18.1.4.1.2 | INTEGER | read-write | mandatory |
| upsOutputRelayConfigCause OBJECT-TYPE This variable sets what causes the output relay state to change. 1 - none 2 - on battery power failure 3 - on battery power failure expect during peak period 4 - low battery while on battery 5 - alarm 6 - fault 7 - output on 8 - output off 9 - online 10 - in bypass | 1.3.6.1.4.1.318.1.1.1.18.1.4.1.3 | INTEGER {outputRelayConfigCauseNone(1), outputRelayConfigCauseOnBatPwrFail(2), outputRelayConfigCauseOnBatPwrFailExceptPeakPeriod(3), outputRelayConfigCauseLoBatWhileOnBat(4), outputRelayConfigCauseAlarm(5), outputRelayConfigCauseFault(6), outputRelayConfigCauseOutputOn(7), outputRelayConfigCauseOutputOff(8), outputRelayConfigCauseOnline(9), outputRelayConfigCauseInBypass(10)} | read-write | mandatory |
| upsOutputRelayConfigPolarity OBJECT-TYPE Configures all output relays with one setting. 1 - all relays act normally open, when logic condition is true, relays are energized 2 - all relays act normally close, when logic condition is true relays are deenergized | 1.3.6.1.4.1.318.1.1.1.18.1.5 | INTEGER {upsOutputRelayAllRelaysEnergizedWhenTrue(1), upsOutputRelayAllRelaysNotEnergizedWhenTrue(2)} | read-write | mandatory |
| upsOutputRelayConfigPeakPeriod OBJECT-TYPE An ASCII string containing the 64 flags representing the peak period setting of the UPS. Flags are numbered 1-64 starting from the left. Each flag is either a '1', representing a flag that is set, or a '0', representing a flag that is /not/ set. The peak period intervals are times that are both: - on the days of the week set by the first 7 flags AND - within the time periods set by the remaining flags. UPS output relays triggered by 'On battery except peak period' will not signal when the UPS is on battery during a peak period. The flags are defined as follows: Flag 1: Sunday Flag 2: Monday Flag 3: Tuesday Flag 4: Wednesday Flag 5: Thursday Flag 6: Friday Flag 7: Saturday Flag 8: 00:00-00:29 Flag 9: 00:30-00:59 Flag 10: 01:00-01:29 Flag 11: 01:30-01:59 Flag 12: 02:00-02:29 Flag 13: 02:30-02:59 Flag 14: 03:00-03:29 Flag 15: 03:30-03:59 Flag 16: 04:00-04:29 Flag 17: 04:30-04:59 Flag 18: 05:00-05:29 Flag 19: 05:30-05:59 Flag 20: 06:00-06:29 Flag 21: 06:30-06:59 Flag 22: 07:00-07:29 Flag 23: 07:30-07:59 Flag 24: 08:00-08:29 Flag 25: 08:30-08:59 Flag 26: 09:00-09:29 Flag 27: 09:30-09:59 Flag 28: 10:00-00:29 Flag 29: 10:30-10:59 Flag 30: 11:00-11:29 Flag 31: 11:30-11:59 Flag 32: 12:00-12:29 Flag 33: 12:30-12:59 Flag 34: 13:00-13:29 Flag 35: 13:30-13:59 Flag 36: 14:00-14:29 Flag 37: 14:30-14:59 Flag 38: 15:00-15:29 Flag 39: 15:30-15:59 Flag 40: 16:00-16:29 Flag 41: 16:30-16:59 Flag 42: 17:00-17:29 Flag 43: 17:30-17:59 Flag 44: 18:00-18:29 Flag 45: 18:30-18:59 Flag 46: 19:00-19:29 Flag 47: 19:30-19:59 Flag 48: 20:00-20:29 Flag 49: 20:30-20:59 Flag 50: 21:00-21:29 Flag 51: 21:30-21:59 Flag 52: 22:00-22:29 Flag 53: 22:30-22:59 Flag 54: 23:00-23:29 Flag 55: 23:30-23:59 Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> To set this OID you can either: - set the 64 flag bits as an ASCII string of '1's and '0's as described above. The same format is used when this OID is read. - or turn on/off an individual flags. Examples: Set for Sundays and Tuesdays from 00:00-01:29: 1010000111000000000000000000000000000000000000000000000000000000 Set Mondays to be part of the peak periods: +2 Set Tuesdays to not be part of the peak periods: -3 Include interval 23:30-23:59 in the peak period: +55 | 1.3.6.1.4.1.318.1.1.1.18.1.6 | DisplayString | read-write | mandatory |
| upsInputContacts OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.18.2 | |||
| upsInputContactStatusTableSize OBJECT-TYPE The number of integrated input contacts on the UPS. | 1.3.6.1.4.1.318.1.1.1.18.2.1 | INTEGER | read-only | mandatory |
| upsInputContactStatusTable OBJECT-TYPE Allows for access of individual contacts. | 1.3.6.1.4.1.318.1.1.1.18.2.2 | not-accessible | mandatory | |
| upsInputContactStatusEntry OBJECT-TYPE The input contacts to access. | 1.3.6.1.4.1.318.1.1.1.18.2.2.1 | not-accessible | mandatory | |
| upsInputContactIndex OBJECT-TYPE The index to the input contact entry. | 1.3.6.1.4.1.318.1.1.1.18.2.2.1.1 | INTEGER | read-only | mandatory |
| upsInputContactState OBJECT-TYPE Getting this variable will return the input contact state. 1 - normal state 2 - abnormal state | 1.3.6.1.4.1.318.1.1.1.18.2.2.1.2 | INTEGER {upsInputContactNormalState(1), upsInputContactAbnormalState(2)} | read-only | mandatory |
| upsInputContactConfigTableSize OBJECT-TYPE The number of integrated input contacts on the UPS. | 1.3.6.1.4.1.318.1.1.1.18.2.3 | INTEGER | read-only | mandatory |
| upsInputContactConfigTable OBJECT-TYPE Allows for access of individual contacts. | 1.3.6.1.4.1.318.1.1.1.18.2.4 | not-accessible | mandatory | |
| upsInputContactConfigEntry OBJECT-TYPE The input contacts to access. | 1.3.6.1.4.1.318.1.1.1.18.2.4.1 | not-accessible | mandatory | |
| upsInputContactConfigIndex OBJECT-TYPE The index to the input contact entry. | 1.3.6.1.4.1.318.1.1.1.18.2.4.1.1 | INTEGER | read-only | mandatory |
| upsInputContactConfigAction OBJECT-TYPE When the input contact changes state, this action occurs. 1 - none 2 - self test 3 - external alarm on 4 - external alarm off 5 - output off no delay 6 - output on | 1.3.6.1.4.1.318.1.1.1.18.2.4.1.2 | INTEGER {upsInputContactConfigActionNone(1), upsInputContactConfigActionSelfTest(2), upsInputContactConfigActionExternalAlarmOn(3), upsInputContactConfigActionExternalAlarmOff(4), upsInputContactConfigActionOutputOffNoDelay(5), upsInputContactConfigActionOutputOn(6)} | read-write | mandatory |
| upsInputContactConfigPolarity OBJECT-TYPE Configures all input contacts with one setting. 1 - all contacts act as normally open 2 - all contacts act as normally closed | 1.3.6.1.4.1.318.1.1.1.18.2.5 | INTEGER {upsInputContactAllContactsClosedEqualsTrue(1), upsInputContactAllContactsOpenEqualsTrue(2)} | read-write | mandatory |
| upsEnergyEfficiency OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.20 | |||
| upsECOmode OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.20.1 | |||
| upsEcoModeFreqTransferRange OBJECT-TYPE Indicates tolerance of bypass AC frequency in Hz to switch on ECO mode. | 1.3.6.1.4.1.318.1.1.1.20.1.1 | INTEGER | read-only | mandatory |
| upsEcoModeHighVoltThreshold OBJECT-TYPE Indicates high threshold on AC voltage in volts to switch on ECO mode. | 1.3.6.1.4.1.318.1.1.1.20.1.2 | INTEGER | read-only | mandatory |
| upsEcoModeLowVoltThreshold OBJECT-TYPE Indicates low threshold on AC voltage in volts to switch on ECO mode. | 1.3.6.1.4.1.318.1.1.1.20.1.3 | INTEGER | read-only | mandatory |
| upsEcoModeSetting OBJECT-TYPE Indicates whether ECO feature is avaiable to this UPS or not. | 1.3.6.1.4.1.318.1.1.1.20.1.4 | INTEGER {enabled(1), disabled(2)} | read-only | mandatory |
| upsEcoModeStatus OBJECT-TYPE Indicates whether UPS is running in ECO mode or not. | 1.3.6.1.4.1.318.1.1.1.20.1.5 | INTEGER {active(1), inactive(2)} | read-only | mandatory |
| upsEcoModeCountSinceReset OBJECT-TYPE Number of times UPS entered into ECO mode since maintenance reset. | 1.3.6.1.4.1.318.1.1.1.20.1.6 | INTEGER | read-only | mandatory |
| upsEcoModeOnlineSinceCommission OBJECT-TYPE Total runtime in online mode with ECO feature enabled once product is authorized to use (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.1.7 | INTEGER | read-only | mandatory |
| upsEcoModeOnlineSinceReset OBJECT-TYPE Total runtime in online mode with ECO feature enabled since maintenance reset (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.1.8 | INTEGER | read-only | mandatory |
| upsEcoModeTotalPercentTimeSinceReset OBJECT-TYPE Indicates percentage of runtime in ECO mode since maintenance reset. | 1.3.6.1.4.1.318.1.1.1.20.1.9 | INTEGER | read-only | mandatory |
| upsEcoModePercentTimeSinceCommission OBJECT-TYPE Indicates percentage of operation time in ECO mode once product is authorized to use. | 1.3.6.1.4.1.318.1.1.1.20.1.10 | INTEGER | read-only | mandatory |
| upsEcoModeTotalTimeSinceReset OBJECT-TYPE Total runtime of UPS in ECO mode since maintenance reset (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.1.11 | INTEGER | read-only | mandatory |
| upsEcoModeTotalTimeSinceCommission OBJECT-TYPE Total runtime in ECO mode once product is authorized to use (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.1.12 | INTEGER | read-only | mandatory |
| upsEcoModeTotalTimeInMonth OBJECT-TYPE Total runtime of UPS in ECO mode since beginning of month (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.1.13 | INTEGER | read-only | mandatory |
| upsEBMmode OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.20.2 | |||
| upsEbmModeSetting OBJECT-TYPE Indicates whether efficiency booster mode feature is avaiable to this UPS or not. | 1.3.6.1.4.1.318.1.1.1.20.2.1 | INTEGER {enabled(1), disabled(2)} | read-only | mandatory |
| upsEbmModeStatus OBJECT-TYPE Indicates whether UPS is running on EBM mode or not. | 1.3.6.1.4.1.318.1.1.1.20.2.2 | INTEGER {active(1), inactive(2)} | read-only | mandatory |
| upsEbmModeCountSinceReset OBJECT-TYPE Number of times UPS entered into efficiency booster mode since maintenance reset. | 1.3.6.1.4.1.318.1.1.1.20.2.3 | INTEGER | read-only | mandatory |
| upsEbmModeTotalTimeInMonth OBJECT-TYPE Total runtime of UPS in efficiency booster mode since beginning of month (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.2.4 | INTEGER | read-only | mandatory |
| upsEbmModeTotalTimeSinceReset OBJECT-TYPE Total runtime of UPS in efficiency booster mode since maintenance reset (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.2.5 | INTEGER | read-only | mandatory |
| upsEbmModeTotalPercentTimeSinceReset OBJECT-TYPE Indicates percentage of runtime in efficiency booster mode since maintenance reset. | 1.3.6.1.4.1.318.1.1.1.20.2.6 | INTEGER | read-only | mandatory |
| upsEbmModeOnlineSinceCommission OBJECT-TYPE Indicates runtime in online mode with EBM feature enabled once product is authorized to use (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.2.7 | INTEGER | read-only | mandatory |
| upsEbmModePercentTimeSinceCommission OBJECT-TYPE Indicates percentage of operation time in efficiency booster mode once product is authorized to use. | 1.3.6.1.4.1.318.1.1.1.20.2.8 | INTEGER | read-only | mandatory |
| upsEbmModeRuntimeSinceCommission OBJECT-TYPE Total runtime in efficiency booster mode once product is authorized to use (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.2.9 | INTEGER | read-only | mandatory |
| upsEbmModeOnlineSinceReset OBJECT-TYPE Total runtime in online mode with EBM feature enabled since maintenance reset (in minutes). | 1.3.6.1.4.1.318.1.1.1.20.2.10 | INTEGER | read-only | mandatory |
| upsEbmModeUpsCount OBJECT-TYPE Number of UPS's running in efficiency booster mode. | 1.3.6.1.4.1.318.1.1.1.20.2.11 | INTEGER | read-only | mandatory |
| upsStatistics OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.22 | |||
| upsBatteryStats OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.22.1 | |||
| upsBatteryStatsReset OBJECT-TYPE Setting this OID to reset(3) will reset the Battery Stats timer. Getting this OID will return: notSupported(1) - reset feature is not supported. noOperation(2) - indicates reset is supported, does nothing. | 1.3.6.1.4.1.318.1.1.1.22.1.1 | INTEGER {notSupported(1), noOperation(2), reset(3)} | read-write | mandatory |
| upsBatteryStatsTimeSinceReset OBJECT-TYPE Time since battery timer reset (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.1.2 | INTEGER | read-only | mandatory |
| upsBatteryStatsTimeOnBattery OBJECT-TYPE Total time for UPS in battery operation (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.1.3 | INTEGER | read-only | mandatory |
| upsOperationalStats OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.22.2 | |||
| upsOpStatsReset OBJECT-TYPE Setting this OID to reset(3) will reset the Operational Stats timer. Getting this OID will return: notSupported(1) - reset feature is not supported. noOperation(2) - indicates reset is supported, does nothing. | 1.3.6.1.4.1.318.1.1.1.22.2.1 | INTEGER {notSupported(1), noOperation(2), reset(3)} | read-write | mandatory |
| upsOpStatsTimeSinceReset OBJECT-TYPE Time since timer reset (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.2.2 | INTEGER | read-only | mandatory |
| upsOpStatsTimeInNormalOperation OBJECT-TYPE Total time for UPS in normal operation since timer reset via upsOpStatsReset (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.2.3 | INTEGER | read-only | mandatory |
| upsOpStatsTimeInBypassOperation OBJECT-TYPE Total time for UPS in bypass operation since timer reset via upsOpStatsReset (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.2.4 | INTEGER | read-only | mandatory |
| upsOpStatsTimeInECOmodeOperation OBJECT-TYPE Total time for UPS in ECO mode since timer reset via upsOpStatsReset (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.2.5 | INTEGER | read-only | mandatory |
| upsOpStatsTimeInECOnversionOperation OBJECT-TYPE Total time for UPS in ECOnversion since timer reset via upsOpStatsReset (in minutes). | 1.3.6.1.4.1.318.1.1.1.22.2.6 | INTEGER | read-only | mandatory |
| upsEnergyEfficiencyStats OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.1.22.3 | |||
| upsEnergyEfficiencyStatsReset OBJECT-TYPE Setting this OID to reset(3) will reset the Energy Efficiency Stats timer. Getting this OID will return: notSupported(1) - reset feature is not supported. noOperation(2) - indicates reset is supported, does nothing. | 1.3.6.1.4.1.318.1.1.1.22.3.1 | INTEGER {notSupported(1), noOperation(2), reset(3)} | read-write | mandatory |
| upsEnergyEfficiencyStatsOutputEnergyTimeSinceReset OBJECT-TYPE Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsOutputEnergyUsage | 1.3.6.1.4.1.318.1.1.1.22.3.2 | INTEGER | read-only | mandatory |
| upsEnergyEfficiencyStatsTimeInECOmode OBJECT-TYPE Total time (in minutes) for UPS in ECO mode since last timer reset via upsEnergyEfficiencyStatsReset | 1.3.6.1.4.1.318.1.1.1.22.3.3 | INTEGER | read-only | optional |
| upsEnergyEfficiencyStatsTimeInECOnversion OBJECT-TYPE Total time (in minutes) for UPS in ECOnversion since last timer reset via upsEnergyEfficiencyStatsReset | 1.3.6.1.4.1.318.1.1.1.22.3.4 | INTEGER | read-only | optional |
| upsEnergyEfficiencyStatsInputEnergyUsage OBJECT-TYPE The input energy usage of the UPS in kWh since timer reset. | 1.3.6.1.4.1.318.1.1.1.22.3.5 | INTEGER | read-only | mandatory |
| upsEnergyEfficiencyStatsOutputEnergyUsage OBJECT-TYPE The output energy usage of the UPS in kWh since timer reset. | 1.3.6.1.4.1.318.1.1.1.22.3.6 | INTEGER | read-only | mandatory |
| upsEnergyEfficiencyStatsInputEnergyTimeSinceReset OBJECT-TYPE Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsInputEnergyUsage | 1.3.6.1.4.1.318.1.1.1.22.3.7 | INTEGER | read-only | mandatory |
| upsEnergyEfficiencyStatsECOmodeTimeSinceReset OBJECT-TYPE Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsTimeInECOmode | 1.3.6.1.4.1.318.1.1.1.22.3.8 | INTEGER | read-only | optional |
| upsEnergyEfficiencyStatsECOnversionTimeSinceReset OBJECT-TYPE Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsTimeInECOnversion | 1.3.6.1.4.1.318.1.1.1.22.3.9 | INTEGER | read-only | optional |
| measureUps OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.2 | |||
| mUpsEnviron OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.2.1 | |||
| mUpsEnvironAmbientTemperature OBJECT-TYPE The ambient temperature in Celsius for Probe 1. | 1.3.6.1.4.1.318.1.1.2.1.1 | Gauge | read-only | mandatory |
| mUpsEnvironRelativeHumidity OBJECT-TYPE The relative humidity as a percentage for Probe 1. | 1.3.6.1.4.1.318.1.1.2.1.2 | Gauge | read-only | mandatory |
| mUpsEnvironAmbientTemperature2 OBJECT-TYPE The ambient temperature in Celsius for Probe 2. | 1.3.6.1.4.1.318.1.1.2.1.3 | Gauge | read-only | mandatory |
| mUpsEnvironRelativeHumidity2 OBJECT-TYPE The relative humidity as a percentage for Probe 2. | 1.3.6.1.4.1.318.1.1.2.1.4 | Gauge | read-only | mandatory |
| mUpsContact OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.2.2 | |||
| mUpsContactNumContacts OBJECT-TYPE The number of contacts supported by the Measure-UPS. | 1.3.6.1.4.1.318.1.1.2.2.1 | INTEGER | read-only | mandatory |
| mUpsContactTable OBJECT-TYPE A list of contacts supported by the Measure-UPS. | 1.3.6.1.4.1.318.1.1.2.2.2 | not-accessible | mandatory | |
| mUpsContactEntry OBJECT-TYPE A contact entry containing information for a given contact. | 1.3.6.1.4.1.318.1.1.2.2.2.1 | not-accessible | mandatory | |
| contactNumber OBJECT-TYPE An index identifying the contact on the Measure-UPS. | 1.3.6.1.4.1.318.1.1.2.2.2.1.1 | INTEGER | read-only | mandatory |
| normalState OBJECT-TYPE The normal operating position of the contact. If the normal operating position cannot be set then it is controlled via the dip switch on the Measure-UPS and is therefore read-only. | 1.3.6.1.4.1.318.1.1.2.2.2.1.2 | INTEGER {unknown(1), open(2), closed(3)} | read-write | mandatory |
| description OBJECT-TYPE The description of the purpose/use of the contact. | 1.3.6.1.4.1.318.1.1.2.2.2.1.3 | DisplayString | read-write | mandatory |
| monitoringStatus OBJECT-TYPE A flag indicating whether this contact is monitored, or not. | 1.3.6.1.4.1.318.1.1.2.2.2.1.4 | INTEGER {unknown(1), enabled(2), disabled(3)} | read-write | mandatory |
| currentStatus OBJECT-TYPE This value indicates the current state of the contact. If the contact is not in its normal state. This value is set to fault(2). | 1.3.6.1.4.1.318.1.1.2.2.2.1.5 | INTEGER {unknown(1), noFault(2), fault(3)} | read-only | mandatory |
| miniSNMPadapter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.3 | |||
| serialPort OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.3.1 | |||
| serialPort1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.3.1.1 | |||
| serialPort2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.3.1.2 | |||
| serialPort2Config OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.3.1.2.1 | |||
| serialPort2Mode OBJECT-TYPE Setting this variable to passthrough will enable mini's port2 behave like a UPS port. Choosing localConsole will enable the port to be used as local console. | 1.3.6.1.4.1.318.1.1.3.1.2.1.1 | INTEGER {localConsole(1), passthrough(2)} | read-write | obsolete |
| serialPort2Control OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.3.1.2.2 | |||
| setPulseOnTXD OBJECT-TYPE Setting this variable to setPulseOnTXD(2) causes adapter to generate a PULSE on TXD pin of serial port 2. The duration in the prototype implementation will be 1 second. Setting this value to noSetPulseOnTXD(1) has no effect. The value noSetPulseOnTXD(1) will always be returned when the variable is read. Setting this value to setTXDLow(3), or setTXDHigh(4) will keep TXD always low or high respectively. | 1.3.6.1.4.1.318.1.1.3.1.2.2.1 | INTEGER {noSetPulseOnTXD(1), setPulseOnTXD(2), setTXDLow(3), setTXDHigh(4)} | read-write | obsolete |
| masterswitch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.4 | |||
| sPDUIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.4.1 | |||
| sPDUIdentHardwareRev OBJECT-TYPE The hardware revision of the PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.4.1.1 | DisplayString | read-only | mandatory |
| sPDUIdentFirmwareRev OBJECT-TYPE An 8 byte ID string identifying the PDU firmware revision. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.4.1.2 | DisplayString | read-only | mandatory |
| sPDUIdentDateOfManufacture OBJECT-TYPE The date when the PDU was manufactured in mm/dd/yy format. This value is set at the factory. The year 2000 will be represented by 00. | 1.3.6.1.4.1.318.1.1.4.1.3 | DisplayString | read-only | mandatory |
| sPDUIdentModelNumber OBJECT-TYPE A 10-character string identifying the model number of the PDU internal. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.4.1.4 | DisplayString | read-only | mandatory |
| sPDUIdentSerialNumber OBJECT-TYPE A 12-character string identifying the serial number of the PDU internal microprocessor. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.4.1.5 | DisplayString | read-only | mandatory |
| sPDUMasterControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.4.2 | |||
| sPDUMasterControlSwitch OBJECT-TYPE Setting this OID to turnAllOnNow (1) will turn all outlets on immediately. Setting this OID to turnAllOnSequence (2) will turn all outlets on as defined by each outlet's sPDUOutletPowerOnTime OID value. Setting this OID to turnAllOff (3) will turn all outlets off immediately. Setting this OID to rebootAllNow (4) will reboot all outlets immediately. For MasterSwitch firmware version 1.X, setting this OID to rebootAllSequence (5) reboots all outlets, with power returned to the outlets in the sequence defined by each outlet's sPDUOutletPowerOnTime OID value. For MasterSwitch firmware version 2.X, setting this OID to rebootAllSequence (5) will cause a turnAllOffSequence to be performed. Once all outlets are off, the MasterSwitch will then delay the sPDUMasterConfigReboot OID time, and then perform a turnAllOnSequence. For MasterSwitch firmware version 2.X, setting this OID to turnAllOffSequence (7) will turn all outlets off as defined by each outlet's sPDUOutletPowerOffTime OID value. For MasterSwitch firmware version 1.X, setting this OID to turnAllOffSequence (7) will have no effect. Getting this OID will return the noCommand (6) value. | 1.3.6.1.4.1.318.1.1.4.2.1 | INTEGER {turnAllOnNow(1), turnAllOnSequence(2), turnAllOffNow(3), rebootAllNow(4), rebootAllSequence(5), noCommand(6), turnAllOffSequence(7)} | read-write | mandatory |
| sPDUMasterState OBJECT-TYPE Getting this OID will cause the status of all outlets to be returned. This OID is provided for informational purposes only. To change the outlet state, the user should use the sPDUOutletCtl OID in the sPDUOutletControlTable. The format of the data returned is a character string consisting of the word 'On' if the outlet is on or 'Off' if the outlet is off. At least one space will delimit each outlet entry in the string. If the outlet states are unknown, the character string 'Unknown' will be returned. This signifies that there is an inconsistency in the PDU. In the rare case that this should happen, the user is advised to shut down all equipment powered by the PDU and then cycle the PDU's power. This will put the PDU in a consistent state. | 1.3.6.1.4.1.318.1.1.4.2.2 | DisplayString | read-only | mandatory |
| sPDUMasterPending OBJECT-TYPE Getting this OID will cause the command pending status of all outlets to be returned. The format of the data returned is a character string consisting of the word 'Yes' if a command is pending for the outlet or 'No' if there is no command pending for the outlet. At least one space will delimit each outlet entry in the string. If the pending states are unknown, the character string 'Unknown' will be returned. This signifies that there is an inconsistency in the PDU. In the rare case that this should happen, the user is advised to shut down all equipment powered by the PDU and then cycle the PDU's power. This will put the PDU in a consistent state. | 1.3.6.1.4.1.318.1.1.4.2.3 | DisplayString | read-only | mandatory |
| sPDUMasterConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.4.3 | |||
| sPDUMasterConfigPowerOn OBJECT-TYPE The amount of delay, in seconds, between when power is provided to the PDU and when the PDU provides basic master power to the outlets. Allowed values are: -1 never apply power automatically. 0 apply power immediately. 15 apply power in 15 seconds. 30 apply power in 30 seconds. 45 apply power in 45 seconds. 60 apply power in 60 seconds (1 minute). 120 apply power in 120 seconds (2 minutes). 300 apply power in 300 seconds (5 minutes). If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.4.3.1 | INTEGER | read-write | mandatory |
| sPDUMasterConfigReboot OBJECT-TYPE During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is read-only for the MasterSwitch version 2.X and is the maximum sPDUOutletRebootDuration OID of the individual outlets. | 1.3.6.1.4.1.318.1.1.4.3.2 | INTEGER | read-write | mandatory |
| sPDUMasterConfigPDUName OBJECT-TYPE The name of the PDU. | 1.3.6.1.4.1.318.1.1.4.3.3 | DisplayString | read-write | mandatory |
| sPDUOutletControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.4.4 | |||
| sPDUOutletControlTableSize OBJECT-TYPE The number of outlets for the PDU. | 1.3.6.1.4.1.318.1.1.4.4.1 | INTEGER | read-only | mandatory |
| sPDUOutletControlTable OBJECT-TYPE Allows for control of individual outlet switches. The number of entries is contained in the sPDUOutletControlTableSize OID. | 1.3.6.1.4.1.318.1.1.4.4.2 | not-accessible | mandatory | |
| sPDUOutletControlEntry OBJECT-TYPE The outlets to control. | 1.3.6.1.4.1.318.1.1.4.4.2.1 | not-accessible | mandatory | |
| sPDUOutletControlIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.4.4.2.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletPending OBJECT-TYPE Reports whether the current outlet has a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. | 1.3.6.1.4.1.318.1.1.4.4.2.1.2 | INTEGER {commandPending(1), noCommandPending(2), commandPendingUnknown(3)} | read-only | mandatory |
| sPDUOutletCtl OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the outletOn (1) value will be returned. If the outlet is off, the outletOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to outletOn (1) will turn the outlet on. Setting this variable to outletOff (2) will turn the outlet off. Setting this variable to outletReboot (3) will reboot the outlet. Setting this variable to outletOnWithDelay (5) will turn the outlet on after the sPDUOutletPowerOnTime OID has elapsed. This option is not valid for MasterSwitch firmware version 1.X. Setting this variable to outletOffWithDelay (6) will turn the outlet off after the sPDUOutletPowerOffTime OID has elapsed. This option is not valid for MasterSwitch firmware version 1.X. Setting this variable to outletRebootWithDelay (7) will turn the outlet off after the sPDUOutletPowerOffTime OID has elapsed, wait the sPDUOutletRebootDuration OID time, then turn the outlet back on. This option is not valid for MasterSwitch firmware version 1.X. | 1.3.6.1.4.1.318.1.1.4.4.2.1.3 | INTEGER {outletOn(1), outletOff(2), outletReboot(3), outletUnknown(4), outletOnWithDelay(5), outletOffWithDelay(6), outletRebootWithDelay(7)} | read-write | mandatory |
| sPDUOutletCtlName OBJECT-TYPE The name of the outlet. Maximum size is 20 characters. This OID is provided for informational purposes only. This value is set by the sPDUOutletName OID. | 1.3.6.1.4.1.318.1.1.4.4.2.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.4.5 | |||
| sPDUOutletConfigTableSize OBJECT-TYPE The number of outlets for the PDU. | 1.3.6.1.4.1.318.1.1.4.5.1 | INTEGER | read-only | mandatory |
| sPDUOutletConfigTable OBJECT-TYPE The list of outlets to configure. The number of entries is defined by the sPDUOutletConfigTableSize OID. | 1.3.6.1.4.1.318.1.1.4.5.2 | not-accessible | mandatory | |
| sPDUOutletConfigEntry OBJECT-TYPE The outlets to control. | 1.3.6.1.4.1.318.1.1.4.5.2.1 | not-accessible | mandatory | |
| sPDUOutletConfigIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.4.5.2.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletPowerOnTime OBJECT-TYPE The amount of time (in seconds) the outlet will delay powering on when the MasterSwitch is powered on. Allowed values are: -1 never power on automatically. 0 power on with the Master Switch. 15 power on 15 seconds after the MasterSwitch has power applied. 30 power on 30 seconds after the MasterSwitch has power applied. 45 power on 45 seconds after the MasterSwitch has power applied. 60 power on 60 seconds (1 minute) after the MasterSwitch has power applied. 120 power on 120 seconds (2 minutes) after the MasterSwitch has power applied. 300 power on 300 seconds (5 minutes) after the MasterSwitch has power applied. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.4.5.2.1.2 | INTEGER | read-write | mandatory |
| sPDUOutletName OBJECT-TYPE The name of the outlet. Maximum size is 20 characters. | 1.3.6.1.4.1.318.1.1.4.5.2.1.3 | DisplayString | read-write | mandatory |
| sPDUOutletPowerOffTime OBJECT-TYPE The amount of time (in seconds) the outlet will delay powering off. Allowed values are: -1 never power off automatically. 0 power off with the MasterSwitch. 15 power off 15 seconds after being commanded. 30 power off 30 seconds after being commanded. 45 power off 45 seconds after being commanded. 60 power off 60 seconds (1 minute) after being commanded. 120 power off 120 seconds (2 minutes) after being commanded. 300 power off 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is not available for MasterSwitch firmware version 1.X. | 1.3.6.1.4.1.318.1.1.4.5.2.1.4 | INTEGER | read-write | mandatory |
| sPDUOutletRebootDuration OBJECT-TYPE During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is not available for MasterSwitch firmware version 1.X. | 1.3.6.1.4.1.318.1.1.4.5.2.1.5 | INTEGER | read-write | mandatory |
| masterswitchVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5 | |||
| sPDUIdentVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.1 | |||
| sPDUIdentVMTableSize OBJECT-TYPE The number of MasterSwitch VMs controllable by this IP address. | 1.3.6.1.4.1.318.1.1.5.1.1 | INTEGER | read-only | mandatory |
| sPDUIdentVMTable OBJECT-TYPE Allows for query of the individual MasterSwitch VMs. The number of entries is contained in the sPDUIdentVMTableSize OID. | 1.3.6.1.4.1.318.1.1.5.1.2 | not-accessible | mandatory | |
| sPDUIdentVMEntry OBJECT-TYPE The MasterSwitch VMs to query. | 1.3.6.1.4.1.318.1.1.5.1.2.1 | not-accessible | mandatory | |
| sPDUIdentVMIndex OBJECT-TYPE The index to the MasterSwitch VM entry. | 1.3.6.1.4.1.318.1.1.5.1.2.1.1 | INTEGER | read-only | mandatory |
| sPDUIdentNameVM OBJECT-TYPE A 23-character string identifying the MasterSwitch VM. | 1.3.6.1.4.1.318.1.1.5.1.2.1.2 | DisplayString | read-only | mandatory |
| sPDUIdentHardwareRevVM OBJECT-TYPE The hardware version of the MasterSwitch VM. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.5.1.2.1.3 | DisplayString | read-only | mandatory |
| sPDUIdentFirmwareRevVM OBJECT-TYPE An 6-character ID string identifying the MasterSwitch VM firmware version. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.5.1.2.1.4 | DisplayString | read-only | mandatory |
| sPDUIdentDateOfManufactureVM OBJECT-TYPE The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.5.1.2.1.5 | DisplayString | read-only | mandatory |
| sPDUIdentModelNumberVM OBJECT-TYPE A 17-character string identifying the model number of the MasterSwitch VM. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.5.1.2.1.6 | DisplayString | read-only | mandatory |
| sPDUIdentSerialNumberVM OBJECT-TYPE A 17-character string identifying the serial number of the MasterSwitch VM. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.5.1.2.1.7 | DisplayString | read-only | mandatory |
| sPDUMasterControlVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.2 | |||
| sPDUMasterControlVMTableSize OBJECT-TYPE The number of MasterSwitch VMs controllable by this IP address. | 1.3.6.1.4.1.318.1.1.5.2.1 | INTEGER | read-only | mandatory |
| sPDUMasterControlVMTable OBJECT-TYPE Allows for control of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterControlVMTableSize OID. | 1.3.6.1.4.1.318.1.1.5.2.2 | not-accessible | mandatory | |
| sPDUMasterControlVMEntry OBJECT-TYPE The MasterSwitch VMs to control. | 1.3.6.1.4.1.318.1.1.5.2.2.1 | not-accessible | mandatory | |
| sPDUMasterControlVMIndex OBJECT-TYPE The index to the MasterSwitch VM entry. | 1.3.6.1.4.1.318.1.1.5.2.2.1.1 | INTEGER | read-only | mandatory |
| sPDUMasterControlVMName OBJECT-TYPE The name of the MasterSwitch VM. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigVMName OID. | 1.3.6.1.4.1.318.1.1.5.2.2.1.2 | DisplayString | read-only | mandatory |
| sPDUMasterControlVMCommand OBJECT-TYPE Setting this OID to immediateAllOnVM (2) will turn all outlets on immediately. Setting this OID to immediateAllOffVM (3) will turn all outlets off immediately. Setting this OID to immediateAllRebootVM (4) will reboot all outlets immediately. Setting this OID to delayedAllOnVM (5) will turn all outlets on as defined by each outlet's sPDUOutletConfigVMPowerOnTime OID value. Setting this OID to delayedAllOffVM (6) will turn all outlets off as defined by each outlet's sPDUOutletConfigVMPowerOffTime OID value. Setting this OID to sequencedAllRebootVM (7) will cause a immediateAllOffVM command to be performed. The MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration OID time, and then perform a delayedAllOnVM command. Setting this OID to delayedAllRebootVM (8) will cause a delayedAllOffVM command to be performed. Each outlet will then wait its sPDUOutletConfigVMRebootDuration before returning power to the outlet. Setting this OID to delayedSequenceAllRebootVM (9) will cause a delayedAllOffVM command to be performed. Once all outlets are off, the MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration OID time, and then perform a delayedAllOnVM command. Setting this OID to cancelAllPendingCommandsVM (10) will cause all pending commands on the MasterSwitch VM to be canceled. Setting this OID to audioAlarmMute (11) will temporarily silence the audible alarm for the duration of the current overload condition. The audible alarm will be activated on subsequent overload alarms. Getting this OID will return the noCommandAllVM (1) value. | 1.3.6.1.4.1.318.1.1.5.2.2.1.3 | INTEGER {noCommandAllVM(1), immediateAllOnVM(2), immediateAllOffVM(3), immediateAllRebootVM(4), delayedAllOnVM(5), delayedAllOffVM(6), sequencedAllRebootVM(7), delayedAllRebootVM(8), delayedSequenceAllRebootVM(9), cancelAllPendingCommandsVM(10), audioAlarmMute(11)} | read-write | mandatory |
| sPDUMasterConfigVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.3 | |||
| sPDUMasterConfigVMTableSize OBJECT-TYPE The number of MasterSwitch VMs configurable by this IP address. | 1.3.6.1.4.1.318.1.1.5.3.1 | INTEGER | read-only | mandatory |
| sPDUMasterConfigVMTable OBJECT-TYPE Allows for configuration of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterConfigVMTableSize OID. | 1.3.6.1.4.1.318.1.1.5.3.2 | not-accessible | mandatory | |
| sPDUMasterConfigVMEntry OBJECT-TYPE The MasterSwitch VMs to configure. | 1.3.6.1.4.1.318.1.1.5.3.2.1 | not-accessible | mandatory | |
| sPDUMasterConfigVMIndex OBJECT-TYPE The index to the MasterSwitch VM entry. | 1.3.6.1.4.1.318.1.1.5.3.2.1.1 | INTEGER | read-only | mandatory |
| sPDUMasterConfigVMName OBJECT-TYPE The name of the MasterSwitch VM. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.5.3.2.1.2 | DisplayString | read-write | mandatory |
| sPDUMasterConfigVMColdstartDelay OBJECT-TYPE The amount of delay, in seconds, between when power is provided to the MasterSwitch VM and when the MasterSwitch VM provides basic master power to the outlets. Allowed values are: -1 never apply power automatically. 0 apply power immediately. 15 apply power in 15 seconds. 30 apply power in 30 seconds. 45 apply power in 45 seconds. 60 apply power in 60 seconds (1 minute). 120 apply power in 120 seconds (2 minutes). 300 apply power in 300 seconds (5 minutes). If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.5.3.2.1.3 | INTEGER | read-write | mandatory |
| sPDUMasterConfigVMAudioAlarmActivated OBJECT-TYPE Setting this OID to audioAlarmActiveNever (1) will disable the audio alarm on the MasterSwitch VM. Setting this OID to audioAlarmActiveOnOverload (2) will activate the audio alarm on the MasterSwitch VM when an overload condition is present. Setting this OID to audioAlarmActiveOnOverloadImminent (3) will activate the audio alarm on the MasterSwitch VM when the load on the MasterSwitch VM has surpassed the sPDUMasterConfigVMHighLoadWarningThreshold OID value. | 1.3.6.1.4.1.318.1.1.5.3.2.1.4 | INTEGER {audioAlarmActiveNever(1), audioAlarmActiveOnOverload(2), audioAlarmActiveOnOverloadImminent(3)} | read-write | mandatory |
| sPDUMasterConfigVMHighLoadWarningThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented as a percentage of full load. | 1.3.6.1.4.1.318.1.1.5.3.2.1.5 | INTEGER (0..100) | read-write | mandatory |
| sPDUMasterConfigVMLowLoadWarningThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented as a percentage of full load. | 1.3.6.1.4.1.318.1.1.5.3.2.1.6 | INTEGER (0..100) | read-write | mandatory |
| sPDUMasterConfigVMOverloadRestriction OBJECT-TYPE This OID controls the behavior of the MasterSwitch VM when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets to turn on. Setting this OID to restrictOnWarning (2) will not allow outlets to turn on if the sPDUMasterConfigVMHighLoadWarningThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets to turn on if the MasterSwitch Vm is in an overload condition. | 1.3.6.1.4.1.318.1.1.5.3.2.1.7 | INTEGER {alwaysAllowTurnON(1), restrictOnWarning(2), restrictOnOverload(3)} | read-write | mandatory |
| sPDUMasterStatusVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.4 | |||
| sPDUMasterStatusVMTableSize OBJECT-TYPE The number of MasterSwitch VMs at this IP address. | 1.3.6.1.4.1.318.1.1.5.4.1 | INTEGER | read-only | mandatory |
| sPDUMasterStatusVMTable OBJECT-TYPE Allows for gathering of status from the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterStatusVMTableSize OID. | 1.3.6.1.4.1.318.1.1.5.4.2 | not-accessible | mandatory | |
| sPDUMasterStatusVMEntry OBJECT-TYPE The MasterSwitch VMs to gather status from. | 1.3.6.1.4.1.318.1.1.5.4.2.1 | not-accessible | mandatory | |
| sPDUMasterStatusVMIndex OBJECT-TYPE The index to the MasterSwitch VM entry. | 1.3.6.1.4.1.318.1.1.5.4.2.1.1 | INTEGER | read-only | mandatory |
| sPDUMasterStatusVMName OBJECT-TYPE The name of the MasterSwitch VM. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.5.4.2.1.2 | DisplayString | read-only | mandatory |
| sPDUMasterStatusVMCommandPending OBJECT-TYPE Getting this OID will return commandPendingMasterTrueVM (1) if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2) will be returned if there are no pending commands. | 1.3.6.1.4.1.318.1.1.5.4.2.1.3 | INTEGER {commandPendingMasterTrueVM(1), commandPendingMasterFalseVM(2)} | read-only | mandatory |
| sPDUMasterStatusVMOverloadCondition OBJECT-TYPE Getting this OID will return overloadConditionTrueVM (1) if the sPDUMasterConfigVMHighLoadWarningThreshold OID is violated. overloadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarningThreshold OID is not violated. | 1.3.6.1.4.1.318.1.1.5.4.2.1.4 | INTEGER {overloadConditionTrueVM(1), overloadConditionFalseVM(2)} | read-only | mandatory |
| sPDUMasterStatusVMLowLoadCondition OBJECT-TYPE Getting this OID will return lowLoadConditionTrueVM (1) if the sPDUMasterConfigVMLowLoadWarningThreshold OID is violated. lowLoadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarningThreshold OID is not violated. | 1.3.6.1.4.1.318.1.1.5.4.2.1.5 | INTEGER {lowLoadConditionTrueVM(1), lowLoadConditionFalseVM(2)} | read-only | mandatory |
| sPDUMasterStatusVMCurrentLoad OBJECT-TYPE Getting this OID will return the total amount of power being consumed by the load. It is represented as a percentage of full load. | 1.3.6.1.4.1.318.1.1.5.4.2.1.6 | INTEGER | read-only | mandatory |
| sPDUMasterStatusVMMaxLoad OBJECT-TYPE Getting this OID will return the total amount of power that this MasterSwitch VM can provide. It is represented in Amps. | 1.3.6.1.4.1.318.1.1.5.4.2.1.7 | INTEGER | read-only | mandatory |
| sPDUMasterStatusVMOutletCount OBJECT-TYPE Getting this OID will return the number of controllable outlets for this MasterSwitch VM. | 1.3.6.1.4.1.318.1.1.5.4.2.1.8 | INTEGER | read-only | mandatory |
| sPDUMasterStatusVMRebootDuration OBJECT-TYPE Getting this OID will return the largest sPDUOutletConfigVMRebootDuration OID time for this MasterSwitch VM. | 1.3.6.1.4.1.318.1.1.5.4.2.1.9 | INTEGER | read-only | mandatory |
| sPDUOutletControlVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.5 | |||
| sPDUOutletControlVMTable OBJECT-TYPE Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.5.5.1 | not-accessible | mandatory | |
| sPDUOutletControlVMEntry OBJECT-TYPE The outlets to control. | 1.3.6.1.4.1.318.1.1.5.5.1.1 | not-accessible | mandatory | |
| sPDUOutletControlVMIndex OBJECT-TYPE The index to the MasterSwitch VM. | 1.3.6.1.4.1.318.1.1.5.5.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletControlVMName OBJECT-TYPE The name of the MasterSwitch VM. Maximum size is 23 characters. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.5.5.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletControlVMOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.5.5.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletControlVMOutletName OBJECT-TYPE The name of the outlet. Maximum size is 23 characters. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.5.5.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletControlVMOutletCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOnVM (1) value will be returned. If the outlet is off, the immediateOffVM (2) value will be returned. Setting this variable to immediateOnVM (1) will immediately turn the outlet on. Setting this variable to immediateOffVM (2) will immediately turn the outlet off. Setting this variable to immediateRebootVM (3) will immediately reboot the outlet. Setting this variable to delayedOnVM (4) will turn the outlet on after the sPDUOutletConfigVMPowerOnTime OID time has elapsed. Setting this variable to delayedOffVM (5) will turn the outlet off after the sPDUOutletConfigVMPowerOffTime OID time has elapsed. Setting this variable to delayedRebootVM (6) will cause the MasterSwitch VM to perform a delayedOffVM command, wait the sPDUOutletConfigVMRebootDuration OID time, and then perform the immediateOnVM command. Setting this variable to cancelPendingCommandVM (7) will cause any pending command to this outlet to be canceled. | 1.3.6.1.4.1.318.1.1.5.5.1.1.5 | INTEGER {immediateOnVM(1), immediateOffVM(2), immediateRebootVM(3), delayedOnVM(4), delayedOffVM(5), delayedRebootVM(6), cancelPendingCommandVM(7)} | read-write | mandatory |
| sPDUOutletConfigVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.6 | |||
| sPDUOutletConfigVMTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.5.6.1 | not-accessible | mandatory | |
| sPDUOutletConfigVMEntry OBJECT-TYPE The outlets to configure. | 1.3.6.1.4.1.318.1.1.5.6.1.1 | not-accessible | mandatory | |
| sPDUOutletConfigVMIndex OBJECT-TYPE The index to the MasterSwitch VM. | 1.3.6.1.4.1.318.1.1.5.6.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletConfigVMName OBJECT-TYPE The name of the MasterSwitch VM. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.5.6.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletConfigVMOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.5.6.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletConfigVMOutletName OBJECT-TYPE The name of the outlet. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.5.6.1.1.4 | DisplayString | read-write | mandatory |
| sPDUOutletConfigVMPowerOnTime OBJECT-TYPE The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 never power on. 0 power on immediately. 15 power on 15 seconds after being commanded. 30 power on 30 seconds after being commanded. 45 power on 45 seconds after being commanded. 60 power on 60 seconds (1 minute) after being commanded. 120 power on 120 seconds (2 minutes) after being commanded. 300 power on 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.5.6.1.1.5 | INTEGER | read-write | mandatory |
| sPDUOutletConfigVMPowerOffTime OBJECT-TYPE The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 never power off automatically. 0 power off immediately. 15 power off 15 seconds after being commanded. 30 power off 30 seconds after being commanded. 45 power off 45 seconds after being commanded. 60 power off 60 seconds (1 minute) after being commanded. 120 power off 120 seconds (2 minutes) after being commanded. 300 power off 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.5.6.1.1.6 | INTEGER | read-write | mandatory |
| sPDUOutletConfigVMRebootDuration OBJECT-TYPE During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. | 1.3.6.1.4.1.318.1.1.5.6.1.1.7 | INTEGER | read-write | mandatory |
| sPDUOutletStatusVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.5.7 | |||
| sPDUOutletStatusVMTable OBJECT-TYPE Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.5.7.1 | not-accessible | mandatory | |
| sPDUOutletStatusVMEntry OBJECT-TYPE The outlets to gather status from. | 1.3.6.1.4.1.318.1.1.5.7.1.1 | not-accessible | mandatory | |
| sPDUOutletStatusVMIndex OBJECT-TYPE The index to the MasterSwitch VM. | 1.3.6.1.4.1.318.1.1.5.7.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletStatusVMName OBJECT-TYPE The name of the MasterSwitch VM. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.5.7.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletStatusVMOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.5.7.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletStatusVMOutletName OBJECT-TYPE The name of the outlet. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.5.7.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletStatusVMOutletState OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the outletStatusOnVM (1) value will be returned. If the outlet is off, the outletStatusOffVM (2) value will be returned. | 1.3.6.1.4.1.318.1.1.5.7.1.1.5 | INTEGER {outletStatusVMOn(1), outletStatusVMOff(2)} | read-only | mandatory |
| sPDUOutletStatusVMCommandPending OBJECT-TYPE Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusVMCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusVMNoCommandPending (2) will be returned. | 1.3.6.1.4.1.318.1.1.5.7.1.1.6 | INTEGER {outletStatusVMCommandPending(1), outletStatusVMNoCommandPending(2)} | read-only | mandatory |
| masterswitchMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6 | |||
| sPDUIdentMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.1 | |||
| sPDUIdentMSPTableSize OBJECT-TYPE The number of MasterSwitch pluses controllable by this IP address. | 1.3.6.1.4.1.318.1.1.6.1.1 | INTEGER | read-only | mandatory |
| sPDUIdentMSPTable OBJECT-TYPE Allows for query of the individual MasterSwitch pluses. The number of entries is contained in the sPDUIdentMSPTableSize OID. | 1.3.6.1.4.1.318.1.1.6.1.2 | not-accessible | mandatory | |
| sPDUIdentMSPEntry OBJECT-TYPE The MasterSwitch pluses to query. | 1.3.6.1.4.1.318.1.1.6.1.2.1 | not-accessible | mandatory | |
| sPDUIdentMSPIndex OBJECT-TYPE The index to the MasterSwitch plus entry. | 1.3.6.1.4.1.318.1.1.6.1.2.1.1 | INTEGER | read-only | mandatory |
| sPDUIdentNameMSP OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.1.2.1.2 | DisplayString | read-only | mandatory |
| sPDUIdentHardwareRevMSP OBJECT-TYPE The hardware version of the MasterSwitch plus. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.6.1.2.1.3 | DisplayString | read-only | mandatory |
| sPDUIdentFirmwareRevMSP OBJECT-TYPE An 6-character ID string identifying the MasterSwitch plus firmware version. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.6.1.2.1.4 | DisplayString | read-only | mandatory |
| sPDUIdentDateOfManufactureMSP OBJECT-TYPE The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.6.1.2.1.5 | DisplayString | read-only | mandatory |
| sPDUIdentModelNumberMSP OBJECT-TYPE A 17-character string identifying the model number of the MasterSwitch plus. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.6.1.2.1.6 | DisplayString | read-only | mandatory |
| sPDUIdentSerialNumberMSP OBJECT-TYPE A 17-character string identifying the serial number of the MasterSwitch plus. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.6.1.2.1.7 | DisplayString | read-only | mandatory |
| sPDUMasterControlMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.2 | |||
| sPDUMasterControlMSPTableSize OBJECT-TYPE The number of MasterSwitch pluses controllable by this IP address. | 1.3.6.1.4.1.318.1.1.6.2.1 | INTEGER | read-only | mandatory |
| sPDUMasterControlMSPTable OBJECT-TYPE Allows for control of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterControlMSPTableSize OID. | 1.3.6.1.4.1.318.1.1.6.2.2 | not-accessible | mandatory | |
| sPDUMasterControlMSPEntry OBJECT-TYPE The MasterSwitch pluses to control. | 1.3.6.1.4.1.318.1.1.6.2.2.1 | not-accessible | mandatory | |
| sPDUMasterControlMSPIndex OBJECT-TYPE The index to the MasterSwitch plus entry. | 1.3.6.1.4.1.318.1.1.6.2.2.1.1 | INTEGER | read-only | mandatory |
| sPDUMasterControlMSPName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.2.2.1.2 | DisplayString | read-only | mandatory |
| sPDUMasterControlMSPCommand OBJECT-TYPE Setting this OID to immediateAllOnMSP (2) will turn all outlets on immediately. Setting this OID to sequencedAllOnMSP (3) will turn all outlets on as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. Setting this OID to immediateAllOffMSP (4) will turn all outlets off immediately. Setting this OID to gracefulAllRebootMSP (5) will reboot all outlets (after the device running PowerChute confirms shutdown) as defined by each outlet's sPDUOutletConfigMSPRebootDuration OID time value. Setting this OID to immediateAllRebootMSP (6) will reboot all outlets immediately. Setting this OID to gracefulAllShutdownMSP (7) will shutdown all outlets (after the device running PowerChute confirms shutdown) as defined by each outlet's sPDUOutletConfigMSPPowerOffDelay OID time value. Each outlet will then turn on after the sum of its sPDUOutletConfigMSPRestartDelay and sPDUOutletConfigMSPPowerOnDelay OID values. Setting this OID to overrideAllBatCapThreshMSP (8) will cause the outlet to ignore the Battery Capacity Threshold and proceed turning on the outlets as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. Setting this OID to cancelAllPendingCommandsMSP (9) will cause all pending commands on the MasterSwitch plus to be canceled. Setting this OID to restoreFactoryDefaultsMSP (10) will cause the settings of the MasterSwitch plus to be restored to the factory defaults. Getting this OID will return the noCommandAllMSP (1) value. | 1.3.6.1.4.1.318.1.1.6.2.2.1.3 | INTEGER {noCommandAllMSP(1), immediateAllOnMSP(2), sequencedAllOnMSP(3), immediateAllOffMSP(4), gracefulAllRebootMSP(5), immediateAllRebootMSP(6), gracefulAllShutdownMSP(7), overrideAllBatCapThreshMSP(8), cancelAllPendingCommandsMSP(9), restoreFactoryDefaultsMSP(10)} | read-write | mandatory |
| sPDUMasterConfigMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.3 | |||
| sPDUMasterConfigMSPTableSize OBJECT-TYPE The number of MasterSwitch pluses configurable by this IP address. | 1.3.6.1.4.1.318.1.1.6.3.1 | INTEGER | read-only | mandatory |
| sPDUMasterConfigMSPTable OBJECT-TYPE Allows for configuration of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterConfigMSPTableSize OID. | 1.3.6.1.4.1.318.1.1.6.3.2 | not-accessible | mandatory | |
| sPDUMasterConfigMSPEntry OBJECT-TYPE The MasterSwitch pluses to configure. | 1.3.6.1.4.1.318.1.1.6.3.2.1 | not-accessible | mandatory | |
| sPDUMasterConfigMSPIndex OBJECT-TYPE The index to the MasterSwitch plus entry. | 1.3.6.1.4.1.318.1.1.6.3.2.1.1 | INTEGER | read-only | mandatory |
| sPDUMasterConfigMSPName OBJECT-TYPE The name of the MasterSwitch plus. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.6.3.2.1.2 | DisplayString | read-write | mandatory |
| sPDUMasterConfigMSPPowerOnTimeDelay OBJECT-TYPE The amount of delay, in seconds, between when power is provided to the MasterSwitch plus and when the MasterSwitch plus provides basic master power to the outlets. Allowed values are: 0 - 9999 seconds (0 - 2hrs, 46 mins, 39 secs). 0 indicates to apply power immediately. | 1.3.6.1.4.1.318.1.1.6.3.2.1.3 | INTEGER (0..9999) | read-write | mandatory |
| sPDUMasterConfigMSPManualButton OBJECT-TYPE Setting this OID to manualButtonDisabled (1) will disable the manual button on the MasterSwitch plus. Setting this OID to manualButtonEnabled (2) will enable the manual button on the MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.3.2.1.4 | INTEGER {manualButtonDisabled(1), manualButtonEnabled(2)} | read-write | mandatory |
| sPDUMasterStatusMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.4 | |||
| sPDUMasterStatusMSPTableSize OBJECT-TYPE The number of MasterSwitch pluses at this IP address. | 1.3.6.1.4.1.318.1.1.6.4.1 | INTEGER | read-only | mandatory |
| sPDUMasterStatusMSPTable OBJECT-TYPE Allows for gathering of status from the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterStatusMSPTableSize OID. | 1.3.6.1.4.1.318.1.1.6.4.2 | not-accessible | mandatory | |
| sPDUMasterStatusMSPEntry OBJECT-TYPE The MasterSwitch pluses to gather status from. | 1.3.6.1.4.1.318.1.1.6.4.2.1 | not-accessible | mandatory | |
| sPDUMasterStatusMSPIndex OBJECT-TYPE The index to the MasterSwitch plus entry. | 1.3.6.1.4.1.318.1.1.6.4.2.1.1 | INTEGER | read-only | mandatory |
| sPDUMasterStatusMSPName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.4.2.1.2 | DisplayString | read-only | mandatory |
| sPDUMasterStatusMSPOutletCount OBJECT-TYPE Getting this OID will return the number of controllable outlets for this MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.4.2.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletControlMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.5 | |||
| sPDUOutletControlMSPTable OBJECT-TYPE Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. | 1.3.6.1.4.1.318.1.1.6.5.1 | not-accessible | mandatory | |
| sPDUOutletControlMSPEntry OBJECT-TYPE The outlets to control. | 1.3.6.1.4.1.318.1.1.6.5.1.1 | not-accessible | mandatory | |
| sPDUOutletControlMSPIndex OBJECT-TYPE The index to the MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.5.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletControlMSPName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.5.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletControlMSPOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.6.5.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletControlMSPOutletName OBJECT-TYPE The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.5.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletControlMSPOutletCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOnMSP (1) value will be returned. If the outlet is off, the immediateOffMSP (3) value will be returned. Setting this variable to immediateOnMSP (1) will immediately turn the outlet on. Setting this variable to delayedOnMSP (2) will turn the outlet on after the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. Setting this variable to immediateOffMSP (3) will immediately turn the outlet off. Setting this variable to gracefulRebootMSP (4) will cause the outlet to wait for device confirmation (if applicable) and then turn the outlet off after the sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn on after the sPDUOutletConfigMSPRebootDuration OID time has elapsed. Setting this variable to immediateRebootMSP (5) will immediately reboot the outlet. Setting this variable to gracefulshutdownMSP (6) will cause the outlet to wait for device confirmation (if applicable) and then turn the outlet off after the sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn on after the sum of the sPDUOutletConfigMSPRestartTime OID time and the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. Setting this variable to overrideBatCapThreshMSP (7) will cause the outlet to ignore the Battery Capacity Threshold and proceed waiting on the sPDUOutletConfigMSPPowerOnDelay OID time before turning the outlet on. Setting this variable to cancelPendingCommandMSP (8) will cause any pending command to this outlet to be canceled. | 1.3.6.1.4.1.318.1.1.6.5.1.1.5 | INTEGER {immediateOnMSP(1), delayedOnMSP(2), immediateOffMSP(3), gracefulRebootMSP(4), immediateRebootMSP(5), gracefulshutdownMSP(6), overrideBatCapThreshMSP(7), cancelPendingCommandMSP(8)} | read-write | mandatory |
| sPDUOutletConfigMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.6 | |||
| sPDUOutletConfigMSPall OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.6.1 | |||
| sPDUOutletConfigMSPallTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. | 1.3.6.1.4.1.318.1.1.6.6.1.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPallEntry OBJECT-TYPE The outlets to configure. | 1.3.6.1.4.1.318.1.1.6.6.1.1.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPallIndex OBJECT-TYPE The index to the MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.6.1.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPallName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.6.1.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPallOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.6.6.1.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPallOutletName OBJECT-TYPE The name of the outlet. Maximum size is 23 characters. | 1.3.6.1.4.1.318.1.1.6.6.1.1.1.4 | DisplayString | read-write | mandatory |
| sPDUOutletConfigMSPallOutletCtrlMode OBJECT-TYPE Setting this OID to modeGracefulShutdown (1) will put this outlet into the Graceful Shutdown control mode. Setting this OID to modeAnnunciator (2) will put this outlet into the Annunciator control mode. | 1.3.6.1.4.1.318.1.1.6.6.1.1.1.5 | INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)} | read-write | mandatory |
| sPDUOutletConfigMSPgs OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.6.2 | |||
| sPDUOutletConfigMSPgsTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. | 1.3.6.1.4.1.318.1.1.6.6.2.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPgsEntry OBJECT-TYPE The outlets to configure. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPgsIndex OBJECT-TYPE The index to the MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPgsName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPgsOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPgsOutletName OBJECT-TYPE The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPgsOutletCtrlMode OBJECT-TYPE The Control Mode of the outlet. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.5 | INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)} | read-only | mandatory |
| sPDUOutletConfigMSPgsDeviceConfirm OBJECT-TYPE Setting this OID to deviceConfirmNo (1) cause the outlet to NOT wait for device confirmation while performing graceful operations. Setting this OID to deviceConfirmYes (2) cause the outlet to wait for device confirmation while performing graceful operations. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.6 | INTEGER {deviceConfirmNo(1), deviceConfirmYes(2)} | read-write | mandatory |
| sPDUOutletConfigMSPgsLowBattWarning OBJECT-TYPE The amount of delay, in 6 second intervals, between when the UPS goes on battery and the power down sequence for the outlet is initiated. Allowed values are: -2 - Never initiate the power down sequence on low battery warning. -1 - Initiate power down sequence based on remaining runtime. 1 - 9999 six second intervals (6 secs - 16hrs, 39 mins, 54 secs). 0 indicates to immediately initiate power down sequence on low battery warning. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.7 | INTEGER (-2..9999) | read-write | mandatory |
| sPDUOutletConfigMSPgsLowBattMult OBJECT-TYPE Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is set to -1 (On Runtime Remaining). Allows you to set the value to stagger the shutdown sequence of the outlets. 1 provides the longest delay (the outlet to shutoff first), and 7 would provide the shortest delay (the outlet to shut off last). Allowed values are: 1 - 7. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.8 | INTEGER (1..7) | read-write | mandatory |
| sPDUOutletConfigMSPgsRestartDelay OBJECT-TYPE The amount of delay, in 6 minute intervals, between when the outlet is turned off and the outlet is turned back on when performing a Graceful Shutdown. Allowed values are: -1 - Never turn outlet back on after a Graceful shutdown. 0 - 9999 six minute intervals (0 - 999hrs, 54 mins). | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.9 | INTEGER (-1..9999) | read-write | mandatory |
| sPDUOutletConfigMSPgsPowerOnDelay OBJECT-TYPE The amount of delay, in seconds, between the UPS entering normal (on-line) state and the outlet being powered on. Allowed values are: -1 - Remain Off when the UPS enters the on-line state. 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.10 | INTEGER (-1..9999) | read-write | mandatory |
| sPDUOutletConfigMSPgsPowerOffDelay OBJECT-TYPE The amount of delay, in seconds, between when the server shuts down and the outlet is powered off. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.11 | INTEGER (0..9999) | read-write | mandatory |
| sPDUOutletConfigMSPgsBattCapThresh OBJECT-TYPE The minimum battery capacity, as a percent (0-100%), required of the UPS before an outlet will be allowed to power on. Allowed values are: 0 - 100 percent. | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.12 | INTEGER (0..100) | read-write | mandatory |
| sPDUOutletConfigMSPgsRebootDuration OBJECT-TYPE The amount of delay, in seconds, from outlet off until outlet on during a reboot. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). | 1.3.6.1.4.1.318.1.1.6.6.2.1.1.13 | INTEGER (0..9999) | read-write | mandatory |
| sPDUOutletConfigMSPannun OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.6.3 | |||
| sPDUOutletConfigMSPannunTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. | 1.3.6.1.4.1.318.1.1.6.6.3.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPannunEntry OBJECT-TYPE The outlets to configure. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPannunIndex OBJECT-TYPE The index to the MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPannunName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPannunOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPannunOutletName OBJECT-TYPE The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPannunOutletCtrlMode OBJECT-TYPE The Control Mode of the outlet. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.5 | INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)} | read-only | mandatory |
| sPDUOutletConfigMSPannunInitialState OBJECT-TYPE Setting this OID to initialStateOff (1) causes the outlet to default to off when in the non-alarmed condition. Setting this OID to initialStateOn (2) causes the outlet to default to on when in the non-alarmed condition. | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.6 | INTEGER {initialStateOff(1), initialStateOn(2)} | read-write | mandatory |
| sPDUOutletConfigMSPannunAlarmActionDly OBJECT-TYPE The amount of time, in seconds, that an enabled Measure-UPS alarm must be asserted before an alarm condition is recognized. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). | 1.3.6.1.4.1.318.1.1.6.6.3.1.1.7 | INTEGER (0..9999) | read-write | mandatory |
| sPDUOutletConfigMSPmups OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.6.4 | |||
| sPDUOutletConfigMSPmupsTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID. | 1.3.6.1.4.1.318.1.1.6.6.4.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPmupsEntry OBJECT-TYPE The outlets to configure. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1 | not-accessible | mandatory | |
| sPDUOutletConfigMSPmupsIndex OBJECT-TYPE The index to the MasterSwitch plus. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPmupsName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPmupsOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletConfigMSPmupsOutletName OBJECT-TYPE The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletConfigMSPmupsZone1 OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Zone 1 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 1 alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.5 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsZone2 OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Zone 2 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 2 alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.6 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsZone3 OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Zone 3 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 3 alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.7 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsZone4 OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Zone 4 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 4 alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.8 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP1LowHum OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 1 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low humidity alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.9 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP1HiHum OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 1 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high humidity alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.10 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP1LowTemp OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 1 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low temperature alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.11 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP1HiTemp OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 1 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high temperature alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.12 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP2LowHum OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 2 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low humidity alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.13 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP2HiHum OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 2 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high humidity alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.14 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP2LowTemp OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 2 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low temperature alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.15 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletConfigMSPmupsP2HiTemp OBJECT-TYPE Setting this OID to disableAlarm (1) disables the Probe 2 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high temperature alarm for this outlet. | 1.3.6.1.4.1.318.1.1.6.6.4.1.1.16 | INTEGER {disableAlarm(1), enableAlarm(2)} | read-write | mandatory |
| sPDUOutletStatusMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.6.7 | |||
| sPDUOutletStatusMSPTable OBJECT-TYPE Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.6.7.1 | not-accessible | mandatory | |
| sPDUOutletStatusMSPEntry OBJECT-TYPE The outlets to gather status from. | 1.3.6.1.4.1.318.1.1.6.7.1.1 | not-accessible | mandatory | |
| sPDUOutletStatusMSPIndex OBJECT-TYPE The index to the MasterSwitch MSP. | 1.3.6.1.4.1.318.1.1.6.7.1.1.1 | INTEGER | read-only | mandatory |
| sPDUOutletStatusMSPName OBJECT-TYPE The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. | 1.3.6.1.4.1.318.1.1.6.7.1.1.2 | DisplayString | read-only | mandatory |
| sPDUOutletStatusMSPOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.6.7.1.1.3 | INTEGER | read-only | mandatory |
| sPDUOutletStatusMSPOutletName OBJECT-TYPE The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.7.1.1.4 | DisplayString | read-only | mandatory |
| sPDUOutletStatusMSPOutletState OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the outletStatusMSPOn (1) value will be returned. If the outlet is off, the outletStatusMSPOff (2) value will be returned. | 1.3.6.1.4.1.318.1.1.6.7.1.1.5 | INTEGER {outletStatusMSPOn(1), outletStatusMSPOff(2)} | read-only | mandatory |
| sPDUOutletStatusMSPCommandPending OBJECT-TYPE Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusMSPCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusMSPNoCommandPending (2) will be returned. | 1.3.6.1.4.1.318.1.1.6.7.1.1.6 | INTEGER {outletStatusMSPCommandPending(1), outletStatusMSPNoCommandPending(2)} | read-only | mandatory |
| sPDUOutletStatusMSPOutletCtrlMode OBJECT-TYPE The Control Mode of the outlet. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.6.7.1.1.7 | INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)} | read-only | mandatory |
| dcDM3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7 | |||
| dm3Ident OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.1 | |||
| dm3IdentSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.1.1 | |||
| dm3IdentSysDescriptionTableSize OBJECT-TYPE The number of DC description records. | 1.3.6.1.4.1.318.1.1.7.1.1.1 | INTEGER | read-only | mandatory |
| dm3IdentSysDescriptionTable OBJECT-TYPE Allows for accessing description records of the powerplant. The number of entries is contained in the dm3IdentSysDescriptionTableSize OID. | 1.3.6.1.4.1.318.1.1.7.1.1.2 | not-accessible | mandatory | |
| dm3IdentSysDescriptionEntry OBJECT-TYPE The powerplant description record to reference. | 1.3.6.1.4.1.318.1.1.7.1.1.2.1 | not-accessible | mandatory | |
| dm3IdentSysDescriptionIndex OBJECT-TYPE The index to the DC powerplant description record. | 1.3.6.1.4.1.318.1.1.7.1.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3IdentSysDescriptionText OBJECT-TYPE A 16 character text field describing the DC power plant device. This field can be configured from the dm3ConfigSysDescriptionText OID. | 1.3.6.1.4.1.318.1.1.7.1.1.2.1.2 | DisplayString | read-only | mandatory |
| dm3IdentSysModel OBJECT-TYPE Model type of the DC power plant. | 1.3.6.1.4.1.318.1.1.7.1.1.3 | INTEGER | read-only | mandatory |
| dm3IdentSysCntrlRev OBJECT-TYPE Integer representation of the hardware revision of the Master Controller board. | 1.3.6.1.4.1.318.1.1.7.1.1.4 | INTEGER | read-only | mandatory |
| dm3IdentSysFWVersion OBJECT-TYPE Integer representation of the power plant Master Controller firmware revision. | 1.3.6.1.4.1.318.1.1.7.1.1.5 | INTEGER | read-only | mandatory |
| dm3Config OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2 | |||
| dm3ConfigSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.1 | |||
| dm3ConfigSysDescriptionTableSize OBJECT-TYPE The number of DC description records. | 1.3.6.1.4.1.318.1.1.7.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigSysDescriptionTable OBJECT-TYPE Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTableSize OID. | 1.3.6.1.4.1.318.1.1.7.2.1.2 | not-accessible | mandatory | |
| dm3ConfigSysDescriptionEntry OBJECT-TYPE The powerplant description record to reference. | 1.3.6.1.4.1.318.1.1.7.2.1.2.1 | not-accessible | mandatory | |
| dm3ConfigSysDescriptionIndex OBJECT-TYPE The index to the DC powerplant description record. | 1.3.6.1.4.1.318.1.1.7.2.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigSysDescriptionText OBJECT-TYPE 16 character text field describing the DC power plant device. | 1.3.6.1.4.1.318.1.1.7.2.1.2.1.2 | DisplayString | read-write | mandatory |
| dm3ConfigSysHighTempThresh OBJECT-TYPE Ambient high temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.1.3 | INTEGER | read-write | mandatory |
| dm3ConfigSysHighTempAlarm OBJECT-TYPE For the System High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.1.4 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigSysLowTempThresh OBJECT-TYPE Ambient low temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.1.5 | INTEGER | read-write | mandatory |
| dm3ConfigSysLowTempAlarm OBJECT-TYPE For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.1.6 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigSysHardwareTempAlarm OBJECT-TYPE For the System Hardware Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.1.7 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigSysRemoteAccess OBJECT-TYPE This OID is used to disable remote write access to the power plant. Setting this OID to accessEnabled (1) will have no affect. Setting this OID to accessDisabled (2) will disable the ability to remotely configure the DC powerplant. Once remote access is disabled, it can only be restored from the front panel of the DC power plant. | 1.3.6.1.4.1.318.1.1.7.2.1.8 | INTEGER {accessEnabled(1), accessDisabled(2)} | read-write | mandatory |
| dm3ConfigLVD OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.2 | |||
| dm3ConfigLVDTableSize OBJECT-TYPE The number of DC powerplant LVDs controllable by this IP address. | 1.3.6.1.4.1.318.1.1.7.2.2.1 | INTEGER | read-only | mandatory |
| dm3ConfigLVDTable OBJECT-TYPE Allows for accessing settings of the LVDs. The number of entries is contained in the dm3ConfigLVDTableSize OID. | 1.3.6.1.4.1.318.1.1.7.2.2.2 | not-accessible | mandatory | |
| dm3ConfigLVDEntry OBJECT-TYPE The LVD to configure. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1 | not-accessible | mandatory | |
| dm3ConfigLVDIndex OBJECT-TYPE The index to the DC powerplant LVD. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigLVDName OBJECT-TYPE The name of the LVD. The maximum value is 16 characters. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.2 | DisplayString | read-write | mandatory |
| dm3ConfigLVDEnable OBJECT-TYPE This OID is used to control and indicate if the LVD is on or off. Setting this OID to enabledYes (1) will enable (turn on) the LVD. Setting this OID to enabledNo (2) will disable (turn off) the LVD. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.3 | INTEGER {enabledYes(1), enabledNo(2)} | read-write | mandatory |
| dm3ConfigLVDTripThresh OBJECT-TYPE LVD Trip threshold. If voltage exceeds threshold, the LVD will trip. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.4 | INTEGER | read-write | mandatory |
| dm3ConfigLVDResetThresh OBJECT-TYPE LVD Reset threshold. If voltage exceeds threshold, the LVD will reset. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.5 | INTEGER | read-write | mandatory |
| dm3ConfigLVDOpenAlarm OBJECT-TYPE For the LVD Open Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.6 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigLVDHWAlarm OBJECT-TYPE For the LVD Hardware Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.2.2.1.7 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.3 | |||
| dm3ConfigBattFloatVolt OBJECT-TYPE Battery Float Voltage. This setting controls the power plant voltage. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.1 | INTEGER | read-write | mandatory |
| dm3ConfigBattMaxRecharge OBJECT-TYPE Battery Maximum Recharge Rate. This setting controls the battery max recharge rate. The value is based on C/20 for 240 AHr battery string. Values are represented in thousandths of Amps (mA). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.2 | INTEGER | read-write | mandatory |
| dm3ConfigBattDischargeThresh OBJECT-TYPE Battery discharge threshold. If battery output current exceeds threshold a battery discharge alarm will occur. Values are represented in thousandths of Amps (mA). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.3 | INTEGER | read-write | mandatory |
| dm3ConfigBattDischargeAlarm OBJECT-TYPE For the Battery Discharge Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.4 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattHighVoltThresh OBJECT-TYPE Battery high voltage threshold. If system battery voltage exceeds threshold a battery high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.5 | INTEGER | read-write | mandatory |
| dm3ConfigBattHighVoltAlarm OBJECT-TYPE For the Battery High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.6 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattLowVoltThresh OBJECT-TYPE Battery low voltage threshold. If system battery voltage is under threshold a battery low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.7 | INTEGER | read-write | mandatory |
| dm3ConfigBattLowVoltAlarm OBJECT-TYPE For the Battery Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.8 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattHighTempThresh OBJECT-TYPE Battery high temperature threshold. If system battery temperature exceeds threshold a battery high temperature alarm will occur. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.9 | INTEGER | read-write | mandatory |
| dm3ConfigBattHighTempAlarm OBJECT-TYPE For the Battery High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.10 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattLowTempThresh OBJECT-TYPE Battery low temperature threshold. If system battery temperature is under threshold a battery low temperature alarm will occur. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.11 | INTEGER | read-write | mandatory |
| dm3ConfigBattLowTempAlarm OBJECT-TYPE For the Battery Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.12 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattAmpHour OBJECT-TYPE Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.13 | INTEGER | read-write | mandatory |
| dm3ConfigCompMethod OBJECT-TYPE This OID is used to configure and get the state of the battery temperature compensation. Setting this OID to tempcompOn (1) will enable/turn on the battery temperature compensation. Setting this OID to tempcompOff (2) will disable/turn off the battery temperature compensation. | 1.3.6.1.4.1.318.1.1.7.2.3.14 | INTEGER {tempcompOn(1), tempcompOff(2)} | read-write | mandatory |
| dm3ConfigCompTempCoeff OBJECT-TYPE Compensation Temperature Coefficient. (uV/degC/cell). Units are presented in microvolts. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.15 | INTEGER | read-write | mandatory |
| dm3ConfigHighKneeTemp OBJECT-TYPE High Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.16 | INTEGER | read-write | mandatory |
| dm3ConfigLowKneeTemp OBJECT-TYPE Low Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.3.17 | INTEGER | read-write | mandatory |
| dm3ConfigBattHwCurrentAlarm OBJECT-TYPE For the Battery Current Hardware Alarm (indicating current is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.18 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigBattHwTempAlarm OBJECT-TYPE For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.3.19 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigPowerModules OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4 | |||
| dm3ConfigRectifier OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4.1 | |||
| dm3ConfigRectThresh OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4.1.1 | |||
| dm3ConfigRectHighVoltThresh OBJECT-TYPE Rectifier high voltage threshold. If rectifier voltage exceeds threshold a rectifier high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.1.1.1 | INTEGER | read-write | mandatory |
| dm3ConfigRectLowVoltThresh OBJECT-TYPE Rectifier low voltage threshold. If rectifier voltage is under threshold a rectifier low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.1.1.2 | INTEGER | read-write | mandatory |
| dm3ConfigRectFailSafe OBJECT-TYPE Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers to use in the event of communications loss with the Master Controller or Master Controller board failure. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.1.1.3 | INTEGER | read-write | mandatory |
| dm3ConfigRectFailComm OBJECT-TYPE Rectifier Communication Fail timeout. This OID represents the time interval in which there is no communication between the rectifier and the master controller at which the rectifier will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.1.1.4 | INTEGER | read-write | mandatory |
| dm3ConfigRectAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4.1.2 | |||
| dm3ConfigRectHighVoltAlarm OBJECT-TYPE For the Rectifier High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.1 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigRectLowVoltAlarm OBJECT-TYPE For the Rectifier Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.2 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigRectConfigAlarm OBJECT-TYPE This alarm is activated when a new rectifier is detected; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.3 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigRect1ofNAlarm OBJECT-TYPE This setting indicates the action if ONE rectifier of a N+1 system has failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.4 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigRect2ofNAlarm OBJECT-TYPE This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.5 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigRectDiagAlarm OBJECT-TYPE For the Rectifier Controller Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.6 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigRectImbalanceAlarm OBJECT-TYPE For the Rectifier Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.7 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigRectCurrLimitAlarm OBJECT-TYPE For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.8 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigRectStandbyAlarm OBJECT-TYPE For the Rectifier Standby Alarm (indicating output DC has been turned off); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.9 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigRectFanFailAlarm OBJECT-TYPE For the Rectifier Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.10 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigRectFailAlarm OBJECT-TYPE For the Rectifier Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.11 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigRectHwVoltAlarm OBJECT-TYPE For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.1.2.12 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigConverter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4.2 | |||
| dm3ConfigConvThresh OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4.2.1 | |||
| dm3ConfigConvHighVoltThresh OBJECT-TYPE Converter high voltage threshold. If converter voltage exceeds threshold a converter high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.1 | INTEGER | read-write | mandatory |
| dm3ConfigConvLowVoltThresh OBJECT-TYPE Converter low voltage threshold. If converter voltage exceeds threshold a converter low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.2 | INTEGER | read-write | mandatory |
| dm3ConfigConvFailSafe OBJECT-TYPE Converter Fail Safe point. This OID represents the value sent to converter controllers to use in the event of communications loss with the Master Controller or Master Controller board failure. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.3 | INTEGER | read-write | mandatory |
| dm3ConfigConvSetPoint OBJECT-TYPE Converter Set point. This OID represents the initial set point used in the voltage control loop. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.4 | INTEGER | read-write | mandatory |
| dm3ConfigConvFailMax OBJECT-TYPE Converter Fail Maximum limit. This OID represents the value sent to the converter controllers to define the maximum set point allowed. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.5 | INTEGER | read-write | mandatory |
| dm3ConfigConvFailMin OBJECT-TYPE Converter Fail Minimum limit. This OID represents the value sent to the converter controllers to define the minimum set point allowed. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.6 | INTEGER | read-write | mandatory |
| dm3ConfigConvFailComm OBJECT-TYPE Converter Communication Fail timeout. This OID represents the time interval in which there is no communication between the converter and the master controller at which the converter will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.4.2.1.7 | INTEGER | read-write | mandatory |
| dm3ConfigConvAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.4.2.2 | |||
| dm3ConfigConvHighVoltAlarm OBJECT-TYPE For the Converter High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.1 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigConvLowVoltAlarm OBJECT-TYPE For the Converter Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.2 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigConvConfigAlarm OBJECT-TYPE For the Converter Configuration Alarm (indicating a new converter has been detected); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.3 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigConv1ofNAlarm OBJECT-TYPE For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.4 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigConv2ofNAlarm OBJECT-TYPE For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.5 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigConvDiagAlarm OBJECT-TYPE For the Converter Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.6 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigConvImbalanceAlarm OBJECT-TYPE For the Converter Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.7 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigConvCurrLimitAlarm OBJECT-TYPE For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.8 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigConvStandbyAlarm OBJECT-TYPE For the Converter Standby Alarm (indicating the converter is in the Standby state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.9 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigConvFanFailAlarm OBJECT-TYPE For the Converter Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.10 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigConvFailAlarm OBJECT-TYPE For the Converter Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.11 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigConvHwVoltAlarm OBJECT-TYPE For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system. | 1.3.6.1.4.1.318.1.1.7.2.4.2.2.12 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)} | read-write | mandatory |
| dm3ConfigRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.5 | |||
| dm3ConfigOutputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.5.1 | |||
| dm3ConfigOutRlyTableSize OBJECT-TYPE The number of DC powerplant Output Relays controllable by this IP address. | 1.3.6.1.4.1.318.1.1.7.2.5.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigOutRlyTable OBJECT-TYPE Allows for accessing settings of the Output Relays. The number of entries is contained in the dm3ConfigOutRlyTableSize OID. | 1.3.6.1.4.1.318.1.1.7.2.5.1.2 | not-accessible | mandatory | |
| dm3ConfigOutRlyEntry OBJECT-TYPE The output relay to configure. | 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1 | not-accessible | mandatory | |
| dm3ConfigOutRlyIndex OBJECT-TYPE The index to the DC powerplant output relay. | 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigOutRlyName OBJECT-TYPE The name of the output relay. The maximum value is 16 characters. | 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.2 | DisplayString | read-write | mandatory |
| dm3ConfigOutRlyDelay OBJECT-TYPE Output Relay Delay. This OID represents the time delay from the initiation of an output relay action to when the output relay action does occur. If the alarm condition disappears before the end of the delay, no action will occur. Delay for Major and Minor alarms is not configurable and is always set to 0. Values are represented in hundredths of seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.3 | INTEGER | read-write | mandatory |
| dm3ConfigOutRlyAlarm OBJECT-TYPE Output Relay Alarm. This setting indicates what action to perform in the event of an output relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Relay Alarm for Major and Minor alarms is not configurable and is always set to alarmMajor and alarmMinor respectively. | 1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.4 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigInputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.5.2 | |||
| dm3ConfigInRlyTableSize OBJECT-TYPE The number of DC powerplant Input Relays controllable by this IP address. | 1.3.6.1.4.1.318.1.1.7.2.5.2.1 | INTEGER | read-only | mandatory |
| dm3ConfigInRlyTable OBJECT-TYPE Allows for accessing settings of the Input Relays. The number of entries is contained in the dm3ConfigInRlyTableSize OID. | 1.3.6.1.4.1.318.1.1.7.2.5.2.2 | not-accessible | mandatory | |
| dm3ConfigInRlyEntry OBJECT-TYPE The input relay to configure. | 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1 | not-accessible | mandatory | |
| dm3ConfigInRlyIndex OBJECT-TYPE The index to the DC powerplant input relay. | 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigInRlyName OBJECT-TYPE The name of the input relay. The maximum value is 16 characters. | 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.2 | DisplayString | read-write | mandatory |
| dm3ConfigInRlyDelay OBJECT-TYPE Input Relay Delay. This OID represents the time delay from the initiation of an input relay action to when the input relay action does occur. If the alarm condition disappears before the end of the delay, no action will occur. Values are represented in hundredths of seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively. | 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.3 | INTEGER | read-write | mandatory |
| dm3ConfigInRlyAlarm OBJECT-TYPE Input Relay Alarm. This setting indicates what action to perform in the event of an input relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.4 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigDistribution OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.6 | |||
| dm3ConfigBreakers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.6.1 | |||
| dm3ConfigBreakersTableSize OBJECT-TYPE The number of DC powerplant circuit breakers controllable by this IP address. | 1.3.6.1.4.1.318.1.1.7.2.6.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigBreakersTable OBJECT-TYPE Allows for accessing settings of the circuit breakers. The number of entries is contained in the dm3ConfigBreakersTableSize OID. | 1.3.6.1.4.1.318.1.1.7.2.6.1.2 | not-accessible | mandatory | |
| dm3ConfigBreakersEntry OBJECT-TYPE The circuit breaker to configure. | 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1 | not-accessible | mandatory | |
| dm3ConfigBreakersIndex OBJECT-TYPE The index to the DC powerplant circuit breaker. | 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigBreakersName OBJECT-TYPE The name of the circuit breaker. The maximum value is 16 characters. | 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.2 | DisplayString | read-write | mandatory |
| dm3ConfigBreakersAlarm OBJECT-TYPE Circuit Breaker Alarm. This setting indicates what action to perform in the event of a circuit breaker alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.3 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3ConfigFuses OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.2.6.2 | |||
| dm3ConfigFusesTableSize OBJECT-TYPE The number of DC powerplant Fuses controllable by this IP address. | 1.3.6.1.4.1.318.1.1.7.2.6.2.1 | INTEGER | read-only | mandatory |
| dm3ConfigFusesTable OBJECT-TYPE Allows for accessing settings of the Fuses. The number of entries is contained in the dm3ConfigFusesTableSize OID. | 1.3.6.1.4.1.318.1.1.7.2.6.2.2 | not-accessible | mandatory | |
| dm3ConfigFusesEntry OBJECT-TYPE The fuse to configure. | 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1 | not-accessible | mandatory | |
| dm3ConfigFusesIndex OBJECT-TYPE The index to the DC powerplant fuse. | 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3ConfigFusesName OBJECT-TYPE The name of the fuse. The maximum value is 16 characters. | 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.2 | DisplayString | read-write | mandatory |
| dm3ConfigFusesAlarm OBJECT-TYPE Fuses Alarm. This setting indicates what action to perform in the event of a Fuse alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. | 1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.3 | INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)} | read-write | mandatory |
| dm3Status OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3 | |||
| dm3StatusSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.1 | |||
| dm3StatusSystemTemp OBJECT-TYPE System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.7.3.1.1 | INTEGER | read-only | mandatory |
| dm3StatusSystemStart OBJECT-TYPE Time stamp at DC powerplant initialization. The time is represented as MMM,DD,YYYY,HH:MM:SS. | 1.3.6.1.4.1.318.1.1.7.3.1.2 | DisplayString | read-only | mandatory |
| dm3StatusSysRemoteAccess OBJECT-TYPE Remote Access indicator This setting indicates if configuration (write) access to the powerplant is enabled or disabled at the powerplant level. This value will be accessEnabled (1) if remote configuration is enabled, and accessDisabled (2) if remote configuration is disabled. | 1.3.6.1.4.1.318.1.1.7.3.1.3 | INTEGER {accessEnabled(1), accessDisabled(2)} | read-only | mandatory |
| dm3StatusSysSecurityLevel OBJECT-TYPE This variable shows the current active security access level of controller. This can only be changed directly from the front panel. | 1.3.6.1.4.1.318.1.1.7.3.1.4 | INTEGER | read-only | mandatory |
| dm3StatusSysTempSanity OBJECT-TYPE System temperature sanity indicator. Indicates if the system temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates temperature is reasonable, a value of saneNo (2) indicates it is not. | 1.3.6.1.4.1.318.1.1.7.3.1.5 | INTEGER {saneYES(1), saneNO(2)} | read-only | mandatory |
| dm3StatusSysAlarmState OBJECT-TYPE System Alarm State. Reflects the alarm status of the overall DC system. If a minor alarm is present, the value will be alarmMinor(1). If a major alarm is present, the value will be alarmMajor(2). If both minor and a major alarm is present, the value will be alarmBoth(3). If no alarm is present, the value will be alarmNone(4). | 1.3.6.1.4.1.318.1.1.7.3.1.6 | INTEGER {alarmMinor(1), alarmMajor(2), alarmBoth(3), alarmNone(4)} | read-only | mandatory |
| dm3StatusSysTempUnits OBJECT-TYPE The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.7.3.1.7 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| dm3StatusAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.2 | |||
| dm3StatusAlarmsTableSize OBJECT-TYPE The number of DC powerplant alarms viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.2.1 | INTEGER | read-only | mandatory |
| dm3StatusAlarmsTable OBJECT-TYPE Allows for accessing system alarms. The number of entries is contained in the dm3StatusAlarmsTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.2.2 | not-accessible | mandatory | |
| dm3StatusAlarmsEntry OBJECT-TYPE The alarm to display. | 1.3.6.1.4.1.318.1.1.7.3.2.2.1 | not-accessible | mandatory | |
| dm3StatusAlarmsIndex OBJECT-TYPE The index of the system alarm. | 1.3.6.1.4.1.318.1.1.7.3.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusAlarmsText OBJECT-TYPE The 16 character text describing the active alarm condition. | 1.3.6.1.4.1.318.1.1.7.3.2.2.1.2 | DisplayString | read-only | mandatory |
| dm3StatusBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.3 | |||
| dm3StatusBattCurrent OBJECT-TYPE Battery Current: This OID shows the battery current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.7.3.3.1 | INTEGER | read-only | mandatory |
| dm3StatusBattTemp OBJECT-TYPE Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.7.3.3.2 | INTEGER | read-only | mandatory |
| dm3StatusBattCurrentSanity OBJECT-TYPE Battery current sanity indicator. Indicates if the battery current is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates current is reasonable, a value of saneNo (2) indicates it is not. | 1.3.6.1.4.1.318.1.1.7.3.3.3 | INTEGER {saneYES(1), saneNO(2)} | read-only | mandatory |
| dm3StatusBattTempSanity OBJECT-TYPE Battery temperature sanity indicator. Indicates if the battery temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates temperature is reasonable, a value of saneNo (2) indicates it is not. | 1.3.6.1.4.1.318.1.1.7.3.3.4 | INTEGER {saneYES(1), saneNO(2)} | read-only | mandatory |
| dm3StatusOEM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.4 | |||
| dm3StatusOEMrectOffset OBJECT-TYPE This OID shows the rectifier offset value in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.7.3.4.1 | INTEGER | read-only | mandatory |
| dm3StatusOEMrectGain OBJECT-TYPE This OID shows the rectifier gain value in thousandths of Volts (mV/V). | 1.3.6.1.4.1.318.1.1.7.3.4.2 | INTEGER | read-only | mandatory |
| dm3StatusOEMconvOffset OBJECT-TYPE This OID shows the converter offset value in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.7.3.4.3 | INTEGER | read-only | mandatory |
| dm3StatusOEMconvGain OBJECT-TYPE This OID shows the converter gain value in thousandths of Volts (mV/V). | 1.3.6.1.4.1.318.1.1.7.3.4.4 | INTEGER | read-only | mandatory |
| dm3StatusOEMshuntOffset OBJECT-TYPE This OID shows the shunt offset value in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.7.3.4.5 | INTEGER | read-only | mandatory |
| dm3StatusOEMshuntGain OBJECT-TYPE This OID shows the shunt gain value in thousandths of Amps (mA/A). | 1.3.6.1.4.1.318.1.1.7.3.4.6 | INTEGER | read-only | mandatory |
| dm3StatusLVD OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.5 | |||
| dm3StatusLVDTableSize OBJECT-TYPE The number of DC powerplant LVDs viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.5.1 | INTEGER | read-only | mandatory |
| dm3StatusLVDTable OBJECT-TYPE Allows for accessing settings of the LVDs. The number of entries is contained in the dm3StatusLVDTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.5.2 | not-accessible | mandatory | |
| dm3StatusLVDEntry OBJECT-TYPE The LVD to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.5.2.1 | not-accessible | mandatory | |
| dm3StatusLVDIndex OBJECT-TYPE The index to the DC powerplant LVD. | 1.3.6.1.4.1.318.1.1.7.3.5.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusLVDName OBJECT-TYPE The name of the LVD. The maximum size is 16 characters. The name is set by using the dm3ConfigLVDName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.7.3.5.2.1.2 | DisplayString | read-only | mandatory |
| dm3StatusLVDState OBJECT-TYPE Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened. | 1.3.6.1.4.1.318.1.1.7.3.5.2.1.3 | INTEGER {statusClosed(1), statusOpened(2)} | read-only | mandatory |
| dm3StatusLVDHwFault OBJECT-TYPE Getting this OID will return statusFault (1) if the LVD is faulted. statusNofault (2) will be returned if the LVD is not faulted. | 1.3.6.1.4.1.318.1.1.7.3.5.2.1.4 | INTEGER {statusFault(1), statusNofault(2)} | read-only | mandatory |
| dm3StatusPowerModules OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.6 | |||
| dm3StatusRectifier OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.6.1 | |||
| dm3StatusRectTableSize OBJECT-TYPE The number of DC powerplant rectifiers viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.6.1.1 | INTEGER | read-only | mandatory |
| dm3StatusRectTable OBJECT-TYPE Allows for accessing settings of the rectifiers. The number of entries is contained in the dm3StatusRectTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2 | not-accessible | mandatory | |
| dm3StatusRectEntry OBJECT-TYPE The rectifier to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1 | not-accessible | mandatory | |
| dm3StatusRectIndex OBJECT-TYPE The index to the DC powerplant rectifier. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusRectID OBJECT-TYPE This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.2 | INTEGER | read-only | mandatory |
| dm3StatusRectDesc OBJECT-TYPE This OID shows the 16-character rectifier description. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.3 | DisplayString | read-only | mandatory |
| dm3StatusRectCurrent OBJECT-TYPE This OID shows the rectifier current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.4 | INTEGER | read-only | mandatory |
| dm3StatusRectCurrentLimit OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state. statusFalse (2) will be returned if the rectifier is not in the Current Limit state. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.5 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectStandby OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier is in the Standby state. statusFalse (2) will be returned if the rectifier is not in the Standby state. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.6 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectFanFail OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier Fan has failed. statusFalse (2) will be returned if the rectifier Fan has not failed. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.7 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectFail OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.8 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectDevType OBJECT-TYPE This OID shows the rectifier device type. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.9 | INTEGER | read-only | mandatory |
| dm3StatusRectPhyAddr OBJECT-TYPE This OID shows the rectifier physical address (the address on the bus). | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.10 | INTEGER | read-only | mandatory |
| dm3StatusRectCfg OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier is present after power-up or set-configuration. statusFalse (2) will be returned if the rectifier is not configured. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.11 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectPcbRev OBJECT-TYPE This OID shows the rectifier device PCB serial number. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.12 | INTEGER | read-only | mandatory |
| dm3StatusRectFwVer OBJECT-TYPE This OID shows the rectifier device firmware revision. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.13 | INTEGER | read-only | mandatory |
| dm3StatusRectPresent OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier is present. statusFalse (2) will be returned if the rectifier is not present. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.14 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectDiagPass OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed. statusFalse (2) will be returned if the rectifier diagnostics have not passed. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.15 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusRectState OBJECT-TYPE This OID shows the rectifier device state as defined by the device status register. | 1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.16 | INTEGER | read-only | mandatory |
| dm3StatusSysRectVoltSanity OBJECT-TYPE Rectifier voltage sanity indicator. Indicates if the rectifier voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates voltage is reasonable, a value of saneNo (2) indicates it is not. | 1.3.6.1.4.1.318.1.1.7.3.6.1.3 | INTEGER {saneYES(1), saneNO(2)} | read-only | mandatory |
| dm3StatusSysRectAvailable OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier is available. statusFalse (2) will be returned if the rectifier is not available. | 1.3.6.1.4.1.318.1.1.7.3.6.1.4 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusSysRectType OBJECT-TYPE This OID shows the type of rectifier the system has. There can only be a single type of rectifier in the power plant | 1.3.6.1.4.1.318.1.1.7.3.6.1.5 | INTEGER | read-only | mandatory |
| dm3StatusSysRectVoltage OBJECT-TYPE This OID shows the system level rectifier voltage in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.7.3.6.1.6 | INTEGER | read-only | mandatory |
| dm3StatusSysRectCurrent OBJECT-TYPE This OID shows the system level rectifier current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.7.3.6.1.7 | INTEGER | read-only | mandatory |
| dm3StatusConverter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.6.2 | |||
| dm3StatusConvTableSize OBJECT-TYPE The number of DC powerplant converters viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.6.2.1 | INTEGER | read-only | mandatory |
| dm3StatusConvTable OBJECT-TYPE Allows for viewing status of the converters. The number of entries is contained in the dm3StatusConvTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2 | not-accessible | mandatory | |
| dm3StatusConvEntry OBJECT-TYPE The converter to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1 | not-accessible | mandatory | |
| dm3StatusConvIndex OBJECT-TYPE The index to the DC powerplant converter. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusConvID OBJECT-TYPE This OID shows the converter ID. This enumerates the number of the converter within a group of converters. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.2 | INTEGER | read-only | mandatory |
| dm3StatusConvDesc OBJECT-TYPE This OID shows the 16 character converter description. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.3 | DisplayString | read-only | mandatory |
| dm3StatusConvCurrent OBJECT-TYPE This OID shows the converter current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.4 | INTEGER | read-only | mandatory |
| dm3StatusConvCurrentLimit OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter is in the Current Limit state. statusFalse (2) will be returned if the converter is not in the Current Limit state. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.5 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvStandby OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter is in the Standby state. statusFalse (2) will be returned if the converter is not in the Standby state. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.6 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvFanFail OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter Fan has failed. statusFalse (2) will be returned if the converter Fan has not failed. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.7 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvFail OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter has failed. statusFalse (2) will be returned if the converter has not failed. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.8 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvDevType OBJECT-TYPE This OID shows the converter device type. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.9 | INTEGER | read-only | mandatory |
| dm3StatusConvPhyAddr OBJECT-TYPE This OID shows the converter physical address (the address on the bus). | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.10 | INTEGER | read-only | mandatory |
| dm3StatusConvCfg OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter is present after power-up or set-configuration. statusFalse (2) will be returned if the converter is not configured. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.11 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvPcbRev OBJECT-TYPE This OID shows the converter device PCB serial number. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.12 | INTEGER | read-only | mandatory |
| dm3StatusConvFwVer OBJECT-TYPE This OID shows the converter device firmware version. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.13 | INTEGER | read-only | mandatory |
| dm3StatusConvPresent OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter is present. statusFalse (2) will be returned if the converter is not present. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.14 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvDiagPass OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter diagnostics have passed. statusFalse (2) will be returned if the converter diagnostics have not passed. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.15 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusConvState OBJECT-TYPE This OID shows the converter state as defined by the device status register. | 1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.16 | INTEGER | read-only | mandatory |
| dm3StatusSysConvVoltSanity OBJECT-TYPE Converter voltage sanity indicator. Indicates if the converter voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates voltage is reasonable, a value of saneNo (2) indicates it is not. | 1.3.6.1.4.1.318.1.1.7.3.6.2.3 | INTEGER {saneYES(1), saneNO(2)} | read-only | mandatory |
| dm3StatusSysConvAvailable OBJECT-TYPE Getting this OID will return statusTrue (1) if the converter is available. statusFalse (2) will be returned if the converter is not available. | 1.3.6.1.4.1.318.1.1.7.3.6.2.4 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dm3StatusSysConvType OBJECT-TYPE This OID shows the converter type. | 1.3.6.1.4.1.318.1.1.7.3.6.2.5 | INTEGER | read-only | mandatory |
| dm3StatusSysConvVoltage OBJECT-TYPE This OID shows the system level converter voltage in thousandths of volts (mV). | 1.3.6.1.4.1.318.1.1.7.3.6.2.6 | INTEGER | read-only | mandatory |
| dm3StatusSysConvCurrent OBJECT-TYPE This OID shows the system level converter current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.7.3.6.2.7 | INTEGER | read-only | mandatory |
| dm3StatusRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.7 | |||
| dm3StatusOutputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.7.1 | |||
| dm3StatusOutRlyTableSize OBJECT-TYPE The number of DC powerplant output relays viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.7.1.1 | INTEGER | read-only | mandatory |
| dm3StatusOutRlyTable OBJECT-TYPE Allows for viewing status of the output relays. The number of entries is contained in the dm3StatusOutRlyTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.7.1.2 | not-accessible | mandatory | |
| dm3StatusOutRlyEntry OBJECT-TYPE The output relay to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1 | not-accessible | mandatory | |
| dm3StatusOutRlyIndex OBJECT-TYPE The index to the DC powerplant output relay. | 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusOutRlyName OBJECT-TYPE The name of the output relay. The maximum size is 16 characters. The name is set by using the dm3ConfigOutRlyName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.2 | DisplayString | read-only | mandatory |
| dm3StatusOutRlyStatus OBJECT-TYPE Getting this OID will return statusOn (1) if the output relay is enabled/on. statusOff (2) will be returned if the output relay is disabled/off. | 1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.3 | INTEGER {statusOn(1), statusOff(2)} | read-only | mandatory |
| dm3StatusInputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.7.2 | |||
| dm3StatusInRlyTableSize OBJECT-TYPE The number of DC powerplant input relays viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.7.2.1 | INTEGER | read-only | mandatory |
| dm3StatusInRlyTable OBJECT-TYPE Allows for viewing status of the input relays. The number of entries is contained in the dm3StatusInRlyTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.7.2.2 | not-accessible | mandatory | |
| dm3StatusInRlyEntry OBJECT-TYPE The input relays to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1 | not-accessible | mandatory | |
| dm3StatusInRlyIndex OBJECT-TYPE The index to the DC powerplant input relay. | 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusInRlyName OBJECT-TYPE The name of the input relay. The maximum size is 16 characters. The name is set by using the dm3ConfigInRlyName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.2 | DisplayString | read-only | mandatory |
| dm3StatusInRlyStatus OBJECT-TYPE Getting this OID will return statusOn (1) if the input relay is enabled/on. statusOff (2) will be returned if the input relay is disabled/off. | 1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.3 | INTEGER {statusOn(1), statusOff(2)} | read-only | mandatory |
| dm3StatusDistribution OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.8 | |||
| dm3StatusBreakers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.8.1 | |||
| dm3StatusBreakersTableSize OBJECT-TYPE The number of DC powerplant circuit breakers viewable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.8.1.1 | INTEGER | read-only | mandatory |
| dm3StatusBreakersTable OBJECT-TYPE Allows for viewing status of the circuit breakers. The number of entries is contained in the dm3StatusBreakersTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.8.1.2 | not-accessible | mandatory | |
| dm3StatusBreakersEntry OBJECT-TYPE The circuit breaker to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1 | not-accessible | mandatory | |
| dm3StatusBreakersIndex OBJECT-TYPE The index to the DC powerplant circuit breaker. | 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusBreakersName OBJECT-TYPE The name of the circuit breaker. The maximum size is 16 characters. The name is set by using the dm3ConfigBreakersName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.2 | DisplayString | read-only | mandatory |
| dm3StatusBreakersStatus OBJECT-TYPE Getting this OID will return statusClosed (1) if the circuit breaker is closed. statusOpen (2) will be returned if the circuit breaker is open. | 1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.3 | INTEGER {statusClosed(1), statusOpen(2)} | read-only | mandatory |
| dm3StatusFuses OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.7.3.8.2 | |||
| dm3StatusFusesTableSize OBJECT-TYPE The number of DC powerplant fuses controllable by this IP address. | 1.3.6.1.4.1.318.1.1.7.3.8.2.1 | INTEGER | read-only | mandatory |
| dm3StatusFusesTable OBJECT-TYPE Allows for viewing status of the fuses. The number of entries is contained in the dm3StatusFusesTableSize OID. | 1.3.6.1.4.1.318.1.1.7.3.8.2.2 | not-accessible | mandatory | |
| dm3StatusFusesEntry OBJECT-TYPE The fuse to gather status from. | 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1 | not-accessible | mandatory | |
| dm3StatusFusesIndex OBJECT-TYPE The index to the DC powerplant fuse. | 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.1 | INTEGER | read-only | mandatory |
| dm3StatusFusesName OBJECT-TYPE The name of the fuse. The maximum size is 16 characters. The name is set by using the dm3ConfigFuseName OID. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.2 | DisplayString | read-only | mandatory |
| dm3StatusFusesStatus OBJECT-TYPE Getting this OID will return statusClosed (1) if the fuse is closed. statusOpen (2) will be returned if the fuse is open. | 1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.3 | INTEGER {statusClosed(1), statusOpen(2)} | read-only | mandatory |
| automaticTransferSwitch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8 | |||
| atsIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.1 | |||
| atsIdentHardwareRev OBJECT-TYPE The hardware revision of the Automatic Transfer Switch. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.8.1.1 | DisplayString | read-only | mandatory |
| atsIdentFirmwareRev OBJECT-TYPE A string identifying the Automatic Transfer Switch firmware revision. | 1.3.6.1.4.1.318.1.1.8.1.2 | DisplayString | read-only | mandatory |
| atsIdentFirmwareDate OBJECT-TYPE The date of release for this Automatic Transfer Switch firmware revision. | 1.3.6.1.4.1.318.1.1.8.1.3 | DisplayString | read-only | mandatory |
| atsIdentDateOfManufacture OBJECT-TYPE The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.8.1.4 | DisplayString | read-only | mandatory |
| atsIdentModelNumber OBJECT-TYPE A string identifying the model number of the Automatic Transfer Switch. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.8.1.5 | DisplayString | read-only | mandatory |
| atsIdentSerialNumber OBJECT-TYPE A string identifying the serial number of the Automatic Transfer Switch. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.8.1.6 | DisplayString | read-only | mandatory |
| atsIdentNominalLineVoltage OBJECT-TYPE RMS Utility Voltage measured in Volts. | 1.3.6.1.4.1.318.1.1.8.1.7 | INTEGER | read-only | mandatory |
| atsIdentNominalLineFrequency OBJECT-TYPE Utility Power Frequency measured in Hertz. | 1.3.6.1.4.1.318.1.1.8.1.8 | INTEGER | read-only | mandatory |
| atsIdentDeviceRating OBJECT-TYPE This gives the device rating in Amps | 1.3.6.1.4.1.318.1.1.8.1.9 | INTEGER | read-only | mandatory |
| atsCalibration OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.2 | |||
| atsCalibrationInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.2.1 | |||
| atsCalibrationNumInputs OBJECT-TYPE The number of inputs to this device. | 1.3.6.1.4.1.318.1.1.8.2.1.1 | INTEGER | read-only | mandatory |
| atsCalibrationNumInputPhases OBJECT-TYPE The number of phases per input for this device. | 1.3.6.1.4.1.318.1.1.8.2.1.2 | INTEGER | read-only | mandatory |
| atsCalibrationInputPhaseTable OBJECT-TYPE The number of phases per input line to this device. | 1.3.6.1.4.1.318.1.1.8.2.1.3 | not-accessible | mandatory | |
| atsCalibrationInputPhaseEntry OBJECT-TYPE An entry containing calibration information applicable to a particular input phase. | 1.3.6.1.4.1.318.1.1.8.2.1.3.1 | not-accessible | mandatory | |
| atsCalibrationInputTableIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.8.2.1.3.1.1 | INTEGER | read-only | mandatory |
| atsCalibrationInputPhaseTableIndex OBJECT-TYPE The input phase identifier. | 1.3.6.1.4.1.318.1.1.8.2.1.3.1.2 | INTEGER | read-only | mandatory |
| atsLineVoltageCalibrationFactor OBJECT-TYPE The Line Voltage Calibration factor. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.8.2.1.3.1.3 | INTEGER | read-only | mandatory |
| atsCalibrationPowerSupply OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.2.2 | |||
| atsCalibrationPowerSupplyVoltages OBJECT-TYPE The number of power supply voltages supported by this device. This variable indicates the number of rows in the atsCalibrationPowerSupplyTable. | 1.3.6.1.4.1.318.1.1.8.2.2.1 | INTEGER | read-only | mandatory |
| atsCalibrationPowerSupplyVoltageTable OBJECT-TYPE A list of Power Supply table entries. | 1.3.6.1.4.1.318.1.1.8.2.2.2 | not-accessible | mandatory | |
| atsCalibrationPowerSupplyVoltageEntry OBJECT-TYPE An entry containing information applicable to a particular Power Supply Voltage. | 1.3.6.1.4.1.318.1.1.8.2.2.2.1 | not-accessible | mandatory | |
| atsCalibrationPowerSupplyVoltageTableIndex OBJECT-TYPE The power supply voltage identifier. | 1.3.6.1.4.1.318.1.1.8.2.2.2.1.1 | INTEGER | read-only | mandatory |
| atsCalibrationPowerSupplyVoltage OBJECT-TYPE This value describes the power supply voltage of 24V Source A, 24V Source B, +12V, -12V and 5V. | 1.3.6.1.4.1.318.1.1.8.2.2.2.1.2 | INTEGER {powerSupply24V(1), powerSupply12V(2), powerSupply(3), powerSupply24VSourceB(4), powerSupplyMinus12V(5)} | read-only | mandatory |
| atsPowerSupplyVoltageCalibrationFactor OBJECT-TYPE The Line Voltage Calibration factor. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.8.2.2.2.1.3 | INTEGER | read-only | mandatory |
| ats4gCalibrationPowerSupplyVoltageTable OBJECT-TYPE A list of Power Supply table entries. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.2.3 | not-accessible | mandatory | |
| ats4gCalibrationPowerSupplyVoltageEntry OBJECT-TYPE An entry containing information applicable to a particular Power Supply Voltage. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.2.3.1 | not-accessible | mandatory | |
| ats4gCalibrationPowerSupplyVoltageTableIndex OBJECT-TYPE The power supply voltage identifier. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.2.3.1.1 | INTEGER | read-only | mandatory |
| ats4gCalibrationPowerSupplyVoltage OBJECT-TYPE This value describes the power supply voltage of 24V Source A, 24V Source B, VBoost Source A, VBoost Source B, 3.3V, 1.0V. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.2.3.1.2 | INTEGER {powerSupply24VA(1), powerSupply24VB(2), powerSupplyVBoostA(3), powerSupplyVBoostB(4), powerSupply3Dot3V(5), powerSupply1Dot0V(6)} | read-only | mandatory |
| ats4gPowerSupplyVoltageCalibrationFactor OBJECT-TYPE The Line Voltage Calibration factor. This value is set at the factory. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.2.3.1.3 | INTEGER | read-only | mandatory |
| atsCalibrationOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.2.3 | |||
| atsCalibrationNumOutputs OBJECT-TYPE The number of output lines from this device. This variable indicates the number of rows in the atsCalibrationOutputTable. | 1.3.6.1.4.1.318.1.1.8.2.3.1 | INTEGER | read-only | mandatory |
| atsCalibrationNumOutputPhases OBJECT-TYPE The number of output phases utilized in this device. | 1.3.6.1.4.1.318.1.1.8.2.3.2 | INTEGER | read-only | mandatory |
| atsCalibrationOutputTable OBJECT-TYPE A list of output table entries. | 1.3.6.1.4.1.318.1.1.8.2.3.3 | not-accessible | mandatory | |
| atsCalibrationOutputEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.8.2.3.3.1 | not-accessible | mandatory | |
| atsCalibrationOutputTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.8.2.3.3.1.1 | INTEGER | read-only | mandatory |
| atsCalibrationOutputPhasesTableIndex OBJECT-TYPE Description of each calibration factor for each output phase utilized in this device and one for neutral. | 1.3.6.1.4.1.318.1.1.8.2.3.3.1.2 | INTEGER {phase1(1), phase2(2), phase3(3), neutral(4)} | read-only | mandatory |
| atsOutputCurrentCalibrationFactor OBJECT-TYPE The output current calibration factor measured in Amps. | 1.3.6.1.4.1.318.1.1.8.2.3.3.1.3 | INTEGER | read-only | mandatory |
| ats4gCalibrationOutputTable OBJECT-TYPE A list of output table entries. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.3.4 | not-accessible | mandatory | |
| ats4gCalibrationOutputEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.8.2.3.4.1 | not-accessible | mandatory | |
| ats4gCalibrationOutputTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.8.2.3.4.1.1 | INTEGER | read-only | mandatory |
| ats4gCalibrationOutputPhasesTableIndex OBJECT-TYPE Description of each calibration factor for each output phase utilized in this device and one for neutral. Bank 1 and Bank 2 are for units with two circuit breakers. It is not applicable to AP77xx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.3.4.1.2 | INTEGER {sourceALine(1), sourneBLine(2), bank1(3), bank2(4)} | read-only | mandatory |
| ats4gOutputCurrentCalibrationFactor OBJECT-TYPE The output current calibration factor measured in Amps. It is not applicable to AP7xxx ATS units. | 1.3.6.1.4.1.318.1.1.8.2.3.4.1.3 | INTEGER | read-only | mandatory |
| atsControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.3 | |||
| atsControlResetATS OBJECT-TYPE Setting this variable will cause the Automatic Transfer Switch to perform a power-on reset. It is not applicable to AP44xx units. | 1.3.6.1.4.1.318.1.1.8.3.1 | INTEGER {none(1), reset(2)} | read-write | mandatory |
| atsControlClearAllAlarms OBJECT-TYPE Setting this variable will clear all alarms in the Automatic Transfer Switch. Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.3.2 | INTEGER {none(1), clear(2)} | read-write | mandatory |
| atsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.4 | |||
| atsConfigProductName OBJECT-TYPE A configurable character string. | 1.3.6.1.4.1.318.1.1.8.4.1 | DisplayString | read-write | mandatory |
| atsConfigPreferredSource OBJECT-TYPE This variable returns the preferred source of power when both sources are OK. | 1.3.6.1.4.1.318.1.1.8.4.2 | INTEGER {sourceA(1), sourceB(2), none(3)} | read-write | mandatory |
| atsConfigFrontPanelLockout OBJECT-TYPE Setting this variable to disableFrontPanel(1), prevents source preference configuration of the Automatic Transfer Switch via the Front Panel. Setting this variable to enableFrontPanel(2)allows, source preference configuration of the Automatic Transfer Switch via the Front Panel. | 1.3.6.1.4.1.318.1.1.8.4.3 | INTEGER {disableFrontPanel(1), enableFrontPanel(2)} | read-write | mandatory |
| atsConfigVoltageSensitivity OBJECT-TYPE This variable defines the sensitivity to changes in voltage: high(1) for best protection, low(2) for frequent small line voltage changes. | 1.3.6.1.4.1.318.1.1.8.4.4 | INTEGER {high(1), low(2)} | read-write | mandatory |
| atsConfigTransferVoltageRange OBJECT-TYPE This variable defines the range of acceptable voltage from a power source. If the voltage measured from the selected input source is not within this range, the Automatic Transfer Switch will switch over (transfer) to the alternate power source. | 1.3.6.1.4.1.318.1.1.8.4.5 | INTEGER {wide(1), medium(2), narrow(3)} | read-write | mandatory |
| atsConfigCurrentLimit OBJECT-TYPE The threshold (in Amps) at which an Over Current Alarm will be generated. This OID returns the overload threshold value of the OID atsConfigPhaseOverLoadThreshold for the 1U ATS and OID atsConfigBankOverLoadThreshold of total for the 2U ATS. Setting this OID does not have any impact on the device. | 1.3.6.1.4.1.318.1.1.8.4.6 | INTEGER (0..20) | read-write | mandatory |
| atsConfigResetValues OBJECT-TYPE Resets the ATS configuration to its default values. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.8.4.7 | INTEGER {none(1), reset(2)} | read-write | mandatory |
| atsConfigLineVRMS OBJECT-TYPE To configure the input RMS voltage. | 1.3.6.1.4.1.318.1.1.8.4.8 | INTEGER | read-write | mandatory |
| atsConfigLineVRMSNarrowLimit OBJECT-TYPE To configure the Line VRMS Narrow Limit. | 1.3.6.1.4.1.318.1.1.8.4.9 | INTEGER | read-write | mandatory |
| atsConfigLineVRMSMediumLimit OBJECT-TYPE To configure the Line VRMS Medium Limit. | 1.3.6.1.4.1.318.1.1.8.4.10 | INTEGER | read-write | mandatory |
| atsConfigLineVRMSWideLimit OBJECT-TYPE To configure the Line VRMS Wide Limit. | 1.3.6.1.4.1.318.1.1.8.4.11 | INTEGER | read-write | mandatory |
| atsConfigFrequencyDeviation OBJECT-TYPE To configure the frequency deviation. AP77xx units uses the options of 1, 2, or 3. AP44xx units uses the options of 3, 5, or 10. | 1.3.6.1.4.1.318.1.1.8.4.12 | INTEGER {one(1), two(2), three(3), five(5), ten(10)} | read-write | mandatory |
| atsConfigBankTableSize OBJECT-TYPE The size of the bank table. | 1.3.6.1.4.1.318.1.1.8.4.13 | INTEGER | read-only | mandatory |
| atsConfigBankTable OBJECT-TYPE Allows for configuration of each ATS bank. | 1.3.6.1.4.1.318.1.1.8.4.14 | not-accessible | mandatory | |
| atsConfigBankEntry OBJECT-TYPE This gives access to bank current threshold | 1.3.6.1.4.1.318.1.1.8.4.14.1 | not-accessible | mandatory | |
| atsConfigBankTableIndex OBJECT-TYPE An index to the bank table entry. | 1.3.6.1.4.1.318.1.1.8.4.14.1.1 | INTEGER | read-only | mandatory |
| atsConfigBank OBJECT-TYPE The bank number of an ATS | 1.3.6.1.4.1.318.1.1.8.4.14.1.2 | INTEGER {total(1), bank1(2), bank2(3)} | read-only | mandatory |
| atsConfigBankLowLoadThreshold OBJECT-TYPE A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps disables this warning. Maximum value must be less than the value returned by the atsConfigBankNearOverLoadThreshold OID. | 1.3.6.1.4.1.318.1.1.8.4.14.1.3 | INTEGER | read-write | mandatory |
| atsConfigBankNearOverLoadThreshold OBJECT-TYPE A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the atsConfigBankLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the atsConfigBankOverLoadThreshold OID. | 1.3.6.1.4.1.318.1.1.8.4.14.1.4 | INTEGER | read-write | mandatory |
| atsConfigBankOverLoadThreshold OBJECT-TYPE A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the atsConfigBankNearOverLoadThreshold OID. Maximum value must be less than or equal to the value returned by atsIdentDeviceRating OID. | 1.3.6.1.4.1.318.1.1.8.4.14.1.5 | INTEGER | read-write | mandatory |
| atsConfigPhaseTableSize OBJECT-TYPE The size of the phase table. | 1.3.6.1.4.1.318.1.1.8.4.15 | INTEGER | read-only | mandatory |
| atsConfigPhaseTable OBJECT-TYPE Allows for configuration of each ATS phase. | 1.3.6.1.4.1.318.1.1.8.4.16 | not-accessible | mandatory | |
| atsConfigPhaseEntry OBJECT-TYPE This gives access to phase threshold | 1.3.6.1.4.1.318.1.1.8.4.16.1 | not-accessible | mandatory | |
| atsConfigPhaseTableIndex OBJECT-TYPE The index to the phase table entry. | 1.3.6.1.4.1.318.1.1.8.4.16.1.1 | INTEGER | read-only | mandatory |
| atsConfigPhase OBJECT-TYPE The phase number of an ATS | 1.3.6.1.4.1.318.1.1.8.4.16.1.2 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| atsConfigPhaseLowLoadThreshold OBJECT-TYPE A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps disables this warning. Maximum value must be less than the value returned by the atsConfigPhaseNearOverLoadThreshold OID. | 1.3.6.1.4.1.318.1.1.8.4.16.1.3 | INTEGER | read-write | mandatory |
| atsConfigPhaseNearOverLoadThreshold OBJECT-TYPE A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the atsConfigPhaseLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the atsConfigPhaseOverLoadThreshold OID. | 1.3.6.1.4.1.318.1.1.8.4.16.1.4 | INTEGER | read-write | mandatory |
| atsConfigPhaseOverLoadThreshold OBJECT-TYPE A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the atsConfigPhaseNearOverLoadThreshold OID. Maximum value must be less than or equal to the value returned by atsIdentDeviceRating OID. | 1.3.6.1.4.1.318.1.1.8.4.16.1.5 | INTEGER | read-write | mandatory |
| atsStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.5 | |||
| atsStatusDeviceStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.5.1 | |||
| atsStatusCommStatus OBJECT-TYPE This variable returns the current communication status of the Automatic Transfer Switch. | 1.3.6.1.4.1.318.1.1.8.5.1.1 | INTEGER {atsNeverDiscovered(1), atsCommEstablished(2), atsCommLost(3)} | read-only | mandatory |
| atsStatusSelectedSource OBJECT-TYPE This variable returns the current source of power. | 1.3.6.1.4.1.318.1.1.8.5.1.2 | INTEGER {sourceA(1), sourceB(2)} | read-only | mandatory |
| atsStatusRedundancyState OBJECT-TYPE This variable returns the current redundancy state of the ATS. atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power source if the current source fails. atsFullyRedundant(2) indicates that the ATS will switch over to the alternate power source if the current source fails. | 1.3.6.1.4.1.318.1.1.8.5.1.3 | INTEGER {atsRedundancyLost(1), atsFullyRedundant(2)} | read-only | mandatory |
| atsStatusOverCurrentState OBJECT-TYPE This variable returns the output current state of the ATS. atsOverCurrent(1) indicates that the ATS has exceeded the output current threshold and will not allow a switch over to the alternate power source if the current source fails. atsCurrentOK(2) indicates that the output current is below the output current threshold. This OID returns the value of the OID atsOutputPhaseState for the 1U ATS and OID atsOutputBankState for the 2U ATS. | 1.3.6.1.4.1.318.1.1.8.5.1.4 | INTEGER {atsOverCurrent(1), atsCurrentOK(2)} | read-only | mandatory |
| atsStatus5VPowerSupply OBJECT-TYPE This variable returns the present state of the ATS 5V power supply. atsPowerSupplyFailure(1) indicates the 5V power supply has failed and that the ATS serial port Configuration Menu is not accessible . atsPowerSupplyOK(2) indicates that the ATS 5V power supply is operating within tolerance. This is only supported by AP77xx SKUs. | 1.3.6.1.4.1.318.1.1.8.5.1.5 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatus24VPowerSupply OBJECT-TYPE This variable returns the present state of the ATS 24V power supply for Source A. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the ATS is unable to switch over to the alternate power source if the current source fails. atsPowerSupplyOK(2) indicates that the ATS 24V power supply is operating within tolerance. | 1.3.6.1.4.1.318.1.1.8.5.1.6 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatus24VSourceBPowerSupply OBJECT-TYPE This variable returns the present state of the ATS 24V power supply for Source B. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the ATS is unable to switch over to the alternate power source if the current source fails. atsPowerSupplyOK(2) indicates that the ATS 24V power supply is operating within tolerance. | 1.3.6.1.4.1.318.1.1.8.5.1.7 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatusPlus12VPowerSupply OBJECT-TYPE This variable returns the present state of the ATS 12V power supply. atsPowerSupplyFailure(1) indicates the 12V power supply has failed and the ATS is unable to monitor the current sensors. atsPowerSupplyOK(2) indicates that the ATS 12V power supply is operating within tolerance. This is only supported by AP77xx SKUs. | 1.3.6.1.4.1.318.1.1.8.5.1.8 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatusMinus12VPowerSupply OBJECT-TYPE This variable returns the present state of the ATS -12V power supply. atsPowerSupplyFailure(1) indicates the -12V power supply has failed and the ATS is unable to monitor the current sensors. atsPowerSupplyOK(2) indicates that the ATS -12V power supply is operating within tolerance. This is only supported by AP77xx SKUs. | 1.3.6.1.4.1.318.1.1.8.5.1.9 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatusSwitchStatus OBJECT-TYPE This variable returns the status of the ATS. | 1.3.6.1.4.1.318.1.1.8.5.1.10 | INTEGER {fail(1), ok(2)} | read-only | mandatory |
| atsStatusFrontPanel OBJECT-TYPE This variable returns the present state of the ATS front panel. locked(1): Front panel button cannot be used to change the sources. unlocked(2): Front panel button can be used to change the sources. | 1.3.6.1.4.1.318.1.1.8.5.1.11 | INTEGER {locked(1), unlocked(2)} | read-only | mandatory |
| atsStatusSourceAStatus OBJECT-TYPE This variable returns the status of the Source A. | 1.3.6.1.4.1.318.1.1.8.5.1.12 | INTEGER {fail(1), ok(2)} | read-only | mandatory |
| atsStatusSourceBStatus OBJECT-TYPE This variable returns the status of the Source B. | 1.3.6.1.4.1.318.1.1.8.5.1.13 | INTEGER {fail(1), ok(2)} | read-only | mandatory |
| atsStatusPhaseSyncStatus OBJECT-TYPE This variable returns the status of the phase synch. | 1.3.6.1.4.1.318.1.1.8.5.1.14 | INTEGER {inSync(1), outOfSync(2)} | read-only | mandatory |
| atsStatusVoltageOutStatus OBJECT-TYPE This variable returns the output voltage status. | 1.3.6.1.4.1.318.1.1.8.5.1.15 | INTEGER {fail(1), ok(2)} | read-only | mandatory |
| atsStatusHardwareStatus OBJECT-TYPE This variable returns the status of display board hardware. | 1.3.6.1.4.1.318.1.1.8.5.1.16 | INTEGER {fail(1), ok(2)} | read-only | mandatory |
| atsStatus3dot3VPowerSupply OBJECT-TYPE This variable returns the present state of the ATS 3.3V power supply. atsPowerSupplyFailure(1) indicates the 3.3V power supply has failed. atsPowerSupplyOK(2) indicates that the ATS 3.3V power supply is operating within tolerance. This is only supported by AP44xx units. | 1.3.6.1.4.1.318.1.1.8.5.1.17 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatus1Dot0VPowerSupply OBJECT-TYPE This variable returns the present state of the ATS 1.0V power supply. atsPowerSupplyFailure(1) indicates the 1V power supply has failed. atsPowerSupplyOK(2) indicates that the ATS 1.0V power supply is operating within tolerance. This is only supported by AP44xx units. | 1.3.6.1.4.1.318.1.1.8.5.1.18 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatusVBoostSourceA OBJECT-TYPE This variable returns the present state of the ATS Source A Boost 48V voltage. atsPowerSupplyFailure(1) indicates the ATS Source A Boost 48V voltage has failed. atsPowerSupplyOK(2) indicates that the ATS Source A Boost 48V voltage is operating within tolerance. This is only supported by AP44xx units. | 1.3.6.1.4.1.318.1.1.8.5.1.19 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatusVBoostSourceB OBJECT-TYPE This variable returns the present state of the ATS Source B Boost 48V voltage. atsPowerSupplyFailure(1) indicates the ATS Source B Boost 48V voltage has failed. atsPowerSupplyOK(2) indicates that the ATS Source B Boost 48V voltage is operating within tolerance. This is only supported by AP44xx units. | 1.3.6.1.4.1.318.1.1.8.5.1.20 | INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)} | read-only | mandatory |
| atsStatusResetValues OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.5.2 | |||
| atsStatusResetMaxMinValues OBJECT-TYPE Resets the maximum and minimum ATS values: atsInputMaxVoltage, atsInputMinVoltage, atsInputMaxCurrent, atsInputMinCurrent, atsInputMaxPower, atsInputMinPower, atsOutputMaxCurrent, atsOutputMinCurrent, atsOutputMaxLoad, atsOutputMinLoad, atsOutputMaxPercentLoad, atsOutputMinPercentLoad, atsOutputMaxPower, atsOutputMinPower, atsOutputMaxPercentPower, atsOutputMinPercentPower. These variables represent the maximum and minimum ATS values since the last time they were read or reset by this OID. Values unsupported by this ATS will return (-1). | 1.3.6.1.4.1.318.1.1.8.5.2.1 | INTEGER {none(1), reset(2)} | read-write | mandatory |
| atsStatusInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.5.3 | |||
| atsNumInputs OBJECT-TYPE The number of input feeds to this device. This variable indicates the number of rows in the input table. | 1.3.6.1.4.1.318.1.1.8.5.3.1 | INTEGER | read-only | mandatory |
| atsInputTable OBJECT-TYPE A list of input table entries. The number of entries is given by the value of atsNumInputs. | 1.3.6.1.4.1.318.1.1.8.5.3.2 | not-accessible | mandatory | |
| atsInputEntry OBJECT-TYPE An entry containing information applicable to a particular input. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1 | not-accessible | mandatory | |
| atsInputTableIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1.1 | INTEGER | read-only | mandatory |
| atsNumInputPhases OBJECT-TYPE The number of input phases utilized in this device. The sum of all the atsNumInputPhases variable indicates the number of rows in the input phase table. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1.2 | INTEGER | read-only | mandatory |
| atsInputVoltageOrientation OBJECT-TYPE The input voltage orientation: 1: unknown for this Source 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1.3 | INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)} | read-only | mandatory |
| atsInputFrequency OBJECT-TYPE The input frequency in Hertz, or -1 if it's unsupported by this Source. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1.4 | INTEGER | read-only | mandatory |
| atsInputType OBJECT-TYPE The input type. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1.5 | INTEGER {unknown(1), main(2), bypass(3)} | read-only | mandatory |
| atsInputName OBJECT-TYPE A name given to a particular input. | 1.3.6.1.4.1.318.1.1.8.5.3.2.1.6 | DisplayString | read-write | mandatory |
| atsInputPhaseTable OBJECT-TYPE A list of input table entries. The number of entries is given by the sum of the atsNumInputPhases. | 1.3.6.1.4.1.318.1.1.8.5.3.3 | not-accessible | mandatory | |
| atsInputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input phase. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1 | not-accessible | mandatory | |
| atsInputPhaseTableIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.1 | INTEGER | read-only | mandatory |
| atsInputPhaseIndex OBJECT-TYPE The input phase identifier. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.2 | INTEGER | read-only | mandatory |
| atsInputVoltage OBJECT-TYPE The input voltage in VAC, or -1 if it's unsupported by this Source. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.3 | INTEGER | read-only | mandatory |
| atsInputMaxVoltage OBJECT-TYPE The maximum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.4 | INTEGER | read-only | mandatory |
| atsInputMinVoltage OBJECT-TYPE The minimum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.5 | INTEGER | read-only | mandatory |
| atsInputCurrent OBJECT-TYPE The input current in amperes, or -1 if it's unsupported by this Source. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.6 | INTEGER | read-only | mandatory |
| atsInputMaxCurrent OBJECT-TYPE The maximum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.7 | INTEGER | read-only | mandatory |
| atsInputMinCurrent OBJECT-TYPE The minimum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.8 | INTEGER | read-only | mandatory |
| atsInputPower OBJECT-TYPE The input power in Watts, or -1 if it's unsupported by this Source. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.9 | INTEGER | read-only | mandatory |
| atsInputMaxPower OBJECT-TYPE The maximum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.10 | INTEGER | read-only | mandatory |
| atsInputMinPower OBJECT-TYPE The minimum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.3.3.1.11 | INTEGER | read-only | mandatory |
| atsStatusOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.8.5.4 | |||
| atsNumOutputs OBJECT-TYPE The number of output feeds to this device. This variable indicates the number of rows in the output table. | 1.3.6.1.4.1.318.1.1.8.5.4.1 | INTEGER | read-only | mandatory |
| atsOutputTable OBJECT-TYPE A list of output table entries. The number of entries is given by the value of atsOutputNumPhases. | 1.3.6.1.4.1.318.1.1.8.5.4.2 | not-accessible | mandatory | |
| atsOutputEntry OBJECT-TYPE An entry containing information applicable to a particular output. | 1.3.6.1.4.1.318.1.1.8.5.4.2.1 | not-accessible | mandatory | |
| atsOutputTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.8.5.4.2.1.1 | INTEGER | read-only | mandatory |
| atsNumOutputPhases OBJECT-TYPE The number of output phases utilized in this device. The sum of all the atsNumOutputPhases variable indicates the number of rows in the output phase table. | 1.3.6.1.4.1.318.1.1.8.5.4.2.1.2 | INTEGER | read-only | mandatory |
| atsOutputVoltageOrientation OBJECT-TYPE The output voltage orientation: 1: unknown for this ATS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1. | 1.3.6.1.4.1.318.1.1.8.5.4.2.1.3 | INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)} | read-only | mandatory |
| atsOutputFrequency OBJECT-TYPE The output frequency in Hertz, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.2.1.4 | INTEGER | read-only | mandatory |
| atsOutputPhaseTable OBJECT-TYPE A list of output table entries. The number of entries is given by the sum of the atsNumOutputPhases. | 1.3.6.1.4.1.318.1.1.8.5.4.3 | not-accessible | mandatory | |
| atsOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular output phase. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1 | not-accessible | mandatory | |
| atsOutputPhaseTableIndex OBJECT-TYPE The output identifier. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.1 | INTEGER | read-only | mandatory |
| atsOutputPhaseIndex OBJECT-TYPE Description of each output phase utilized in this device and one for neutral. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.2 | INTEGER {phase1(1), phase2(2), phase3(3), neutral(4)} | read-only | mandatory |
| atsOutputVoltage OBJECT-TYPE The output voltage in VAC, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.3 | INTEGER | read-only | mandatory |
| atsOutputCurrent OBJECT-TYPE The output current in 0.1 amperes drawn by the load on the ATS, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.4 | INTEGER | read-only | mandatory |
| atsOutputMaxCurrent OBJECT-TYPE The maximum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.5 | INTEGER | read-only | mandatory |
| atsOutputMinCurrent OBJECT-TYPE The minimum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.6 | INTEGER | read-only | mandatory |
| atsOutputLoad OBJECT-TYPE The output load in VA, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.7 | INTEGER | read-only | mandatory |
| atsOutputMaxLoad OBJECT-TYPE The maximum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.8 | INTEGER | read-only | mandatory |
| atsOutputMinLoad OBJECT-TYPE The minimum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.9 | INTEGER | read-only | mandatory |
| atsOutputPercentLoad OBJECT-TYPE The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.10 | INTEGER | read-only | mandatory |
| atsOutputMaxPercentLoad OBJECT-TYPE The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.11 | INTEGER | read-only | mandatory |
| atsOutputMinPercentLoad OBJECT-TYPE The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.12 | INTEGER | read-only | mandatory |
| atsOutputPower OBJECT-TYPE The output apparent power in VA, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.13 | INTEGER | read-only | mandatory |
| atsOutputMaxPower OBJECT-TYPE The maximum output power in VAs measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.14 | INTEGER | read-only | mandatory |
| atsOutputMinPower OBJECT-TYPE The minimum output power in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.15 | INTEGER | read-only | mandatory |
| atsOutputPercentPower OBJECT-TYPE The percentage of the ATSpower capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.16 | INTEGER | read-only | mandatory |
| atsOutputMaxPercentPower OBJECT-TYPE The maximum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.17 | INTEGER | read-only | mandatory |
| atsOutputMinPercentPower OBJECT-TYPE The minimum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.18 | INTEGER | read-only | mandatory |
| atsOutputPhaseState OBJECT-TYPE Getting this OID will return the phase load state. normal(1) indicates that the bank is operating properly within the atsConfigPhaseLowLoadThreshold and atsConfigPhaseNearOverLoadThreshold OID values. lowload(2) indicates that the bank load has dropped below the atsConfigPhaseLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. nearoverload(3) indicates that the bank load is greater than or equal to the atsConfigPhaseNearOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. overload(4) indicates that the bank load is greater than or equal to the atsConfigPhaseOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. | 1.3.6.1.4.1.318.1.1.8.5.4.3.1.19 | INTEGER {normal(1), lowload(2), nearoverload(3), overload(4)} | read-only | mandatory |
| atsOutputBankTableSize OBJECT-TYPE The size of the bank table. | 1.3.6.1.4.1.318.1.1.8.5.4.4 | INTEGER | read-only | mandatory |
| atsOutputBankTable OBJECT-TYPE Allows for getting table entries. | 1.3.6.1.4.1.318.1.1.8.5.4.5 | not-accessible | mandatory | |
| atsOutputBankEntry OBJECT-TYPE This gives access to bank table entries | 1.3.6.1.4.1.318.1.1.8.5.4.5.1 | not-accessible | mandatory | |
| atsOutputBankTableIndex OBJECT-TYPE The index to the bank table entry. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.1 | INTEGER | read-only | mandatory |
| atsOutputPhase OBJECT-TYPE The phase number of an ATS | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.2 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| atsOutputBank OBJECT-TYPE The bank number of an ATS | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.3 | INTEGER {total(1), bank1(2), bank2(3)} | read-only | mandatory |
| atsOutputBankCurrent OBJECT-TYPE Getting this OID will return the bank current measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.4 | Gauge | read-only | mandatory |
| atsOutputBankState OBJECT-TYPE Getting this OID will return the bank load state. normal(1) indicates that the bank is operating properly within the atsConfigBankLowLoadThreshold and atsConfigBankNearOverLoadThreshold OID values. lowload(2) indicates that the bank load has dropped below the atsConfigBankLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. nearoverload(3) indicates that the bank load is greater than or equal to the atsConfigBankNearOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. overload(4) indicates that the bank load is greater than or equal to the atsConfigBankOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.5 | INTEGER {normal(1), lowload(2), nearoverload(3), overload(4)} | read-only | mandatory |
| atsOutputBankOutputVoltage OBJECT-TYPE The output voltage in VAC, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.6 | INTEGER | read-only | mandatory |
| atsOutputBankMaxCurrent OBJECT-TYPE The maximum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.7 | INTEGER | read-only | mandatory |
| atsOutputBankMinCurrent OBJECT-TYPE The minimum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.8 | INTEGER | read-only | mandatory |
| atsOutputBankLoad OBJECT-TYPE The output load, on the bank represented by OID atsOutputBank, in VA, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.9 | INTEGER | read-only | mandatory |
| atsOutputBankMaxLoad OBJECT-TYPE The maximum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.10 | INTEGER | read-only | mandatory |
| atsOutputBankMinLoad OBJECT-TYPE The minimum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.11 | INTEGER | read-only | mandatory |
| atsOutputBankPercentLoad OBJECT-TYPE The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank. Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.12 | INTEGER | read-only | mandatory |
| atsOutputBankMaxPercentLoad OBJECT-TYPE The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.13 | INTEGER | read-only | mandatory |
| atsOutputBankMinPercentLoad OBJECT-TYPE The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.14 | INTEGER | read-only | mandatory |
| atsOutputBankPower OBJECT-TYPE The output apparent power in VA on the bank represented by OID atsOutputBank or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.15 | INTEGER | read-only | mandatory |
| atsOutputBankMaxPower OBJECT-TYPE The maximum output power in VA measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.16 | INTEGER | read-only | mandatory |
| atsOutputBankMinPower OBJECT-TYPE The minimum output power in VA measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.17 | INTEGER | read-only | mandatory |
| atsOutputBankPercentPower OBJECT-TYPE The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, or -1 if it's unsupported by this ATS. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.18 | INTEGER | read-only | mandatory |
| atsOutputBankMaxPercentPower OBJECT-TYPE The maximum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.19 | INTEGER | read-only | mandatory |
| atsOutputBankMinPercentPower OBJECT-TYPE The minimum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. | 1.3.6.1.4.1.318.1.1.8.5.4.5.1.20 | INTEGER | read-only | mandatory |
| dc2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9 | |||
| dcmim2Ident OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.1 | |||
| dcmim2IdentSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.1.1 | |||
| dcmim2IdentSysFWVersion OBJECT-TYPE Integer representation of the power plant Master Controller firmware revision. | 1.3.6.1.4.1.318.1.1.9.1.1.1 | INTEGER | read-only | mandatory |
| dcmim2Control OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.2 | |||
| dcmim2ControlSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.2.1 | |||
| dcmim2ControlRunFunctBatteryTest OBJECT-TYPE Getting this OID will return the battery functional test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery functional test off. Setting this OID to battTestOn (2) will turn the battery functional test on. | 1.3.6.1.4.1.318.1.1.9.2.1.1 | INTEGER {battTestOff(1), battTestOn(2)} | read-write | mandatory |
| dcmim2ControlRunCapacityBatteryTest OBJECT-TYPE Getting this OID will return the battery capacity test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery capacity test off. Setting this OID to battTestOn (2) will turn the battery capacity test on. | 1.3.6.1.4.1.318.1.1.9.2.1.2 | INTEGER {battTestOff(1), battTestOn(2)} | read-write | mandatory |
| dcmim2Config OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.3 | |||
| dcmim2ConfigSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.3.1 | |||
| dcmim2ConfigSysHighTempTrip OBJECT-TYPE Trip level (threshold) at which System High Temp alarm condition is created. Range 28 to 100 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.9.3.1.1 | INTEGER | read-write | mandatory |
| dcmim2ConfigSysHighTempReset OBJECT-TYPE Level at which System High Temp alarm condition is reset (cleared). Range 25 to (upper temp - 3) (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.9.3.1.2 | INTEGER | read-write | mandatory |
| dcmim2ConfigSysLowTempTrip OBJECT-TYPE Trip level (threshold) at which System Low Temp alarm condition is created. Range -100 to 10 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.9.3.1.3 | INTEGER | read-write | mandatory |
| dcmim2ConfigSysLowTempReset OBJECT-TYPE Level at which System Low Temp alarm condition is reset (cleared). Range (lower temp + 3) to 13 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.9.3.1.4 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.3.2 | |||
| dcmim2ConfigBattFloatVolt OBJECT-TYPE Battery Float Voltage defined at 25 degrees Celsius. Values are represented in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.3.2.1 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattMaxRecharge OBJECT-TYPE Battery Maximum Recharge Rate. This is the maximum current used during battery charging. Values are represented in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.9.3.2.2 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattMfgCapacity OBJECT-TYPE Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr). | 1.3.6.1.4.1.318.1.1.9.3.2.3 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattType OBJECT-TYPE Type of battery in the powerplant Valid values range from 0 to 254. | 1.3.6.1.4.1.318.1.1.9.3.2.4 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattFunctTestDuration OBJECT-TYPE Duration of the battery functional test. Values are represented in thousandths of seconds (mSecs). | 1.3.6.1.4.1.318.1.1.9.3.2.5 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattFunctTestThresh OBJECT-TYPE Threshold the battery voltage of the system must remain above in order to pass the battery functional test. Values are represented in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.3.2.6 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattCapacityTestPercent OBJECT-TYPE Threshold for good battery capacity test results. Values range from 0 to 100 percent. | 1.3.6.1.4.1.318.1.1.9.3.2.7 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattCapacityTestEndThresh OBJECT-TYPE Safeguard voltage at which battery capacity test will end if there is a battery problem. Values are represented in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.3.2.8 | INTEGER | read-write | mandatory |
| dcmim2ConfigBattCapacityTestCurrent OBJECT-TYPE Constant current value used during battery capacity testing. Values are represented in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.9.3.2.9 | INTEGER | read-write | mandatory |
| dcmim2ConfigLVD OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.3.3 | |||
| dcmim2ConfigLVDTableSize OBJECT-TYPE The number of DC powerplant LVDs controllable by this IP address. | 1.3.6.1.4.1.318.1.1.9.3.3.1 | INTEGER | read-only | mandatory |
| dcmim2ConfigLVDTable OBJECT-TYPE Allows for accessing settings of the LVDs. The number of entries is contained in the dcmim2ConfigLVDTableSize OID. | 1.3.6.1.4.1.318.1.1.9.3.3.2 | not-accessible | mandatory | |
| dcmim2ConfigLVDEntry OBJECT-TYPE The LVD to configure. | 1.3.6.1.4.1.318.1.1.9.3.3.2.1 | not-accessible | mandatory | |
| dcmim2ConfigLVDIndex OBJECT-TYPE The index to the DC powerplant LVD. | 1.3.6.1.4.1.318.1.1.9.3.3.2.1.1 | INTEGER | read-only | mandatory |
| dcmim2ConfigLVDTrip OBJECT-TYPE LVD Trip threshold. System bus voltage at which LVD will trip (open) during a battery backup operation. Values are represented in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.3.3.2.1.2 | INTEGER | read-write | mandatory |
| dcmim2ConfigLVDReset OBJECT-TYPE LVD Reset threshold. System bus voltage at which LVD will reset (close) after AC power has been restored. Values are represented in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.3.3.2.1.3 | INTEGER | read-write | mandatory |
| dcmim2ConfigLVDState OBJECT-TYPE Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened. | 1.3.6.1.4.1.318.1.1.9.3.3.2.1.4 | INTEGER {statusClosed(1), statusOpened(2)} | read-only | mandatory |
| dcmim2Status OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.4 | |||
| dcmim2StatusSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.4.1 | |||
| dcmim2StatusSysRectCurrent OBJECT-TYPE System (Total Rectifier) current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.9.4.1.1 | INTEGER | read-only | mandatory |
| dcmim2StatusSysLoadCurrent OBJECT-TYPE Load current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.9.4.1.2 | INTEGER | read-only | mandatory |
| dcmim2StatusSysBusVoltage OBJECT-TYPE System bus voltage in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.4.1.3 | INTEGER | read-only | mandatory |
| dcmim2StatusSysAmbientTemp OBJECT-TYPE System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.9.4.1.4 | INTEGER | read-only | mandatory |
| dcmim2StatusSysUpTime OBJECT-TYPE Length of time since the DC Powerplant controller has been powered up. | 1.3.6.1.4.1.318.1.1.9.4.1.5 | DisplayString | read-only | mandatory |
| dcmim2StatusSysTempUnits OBJECT-TYPE The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.9.4.1.6 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| dcmim2StatusRectifier OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.4.2 | |||
| dcmim2StatusRectTableSize OBJECT-TYPE The number of DC powerplant rectifiers viewable by this IP address. | 1.3.6.1.4.1.318.1.1.9.4.2.1 | INTEGER | read-only | mandatory |
| dcmim2StatusRectTable OBJECT-TYPE Allows for accessing settings of the rectifiers. The number of entries is contained in the dcmim2StatusRectTableSize OID. | 1.3.6.1.4.1.318.1.1.9.4.2.2 | not-accessible | mandatory | |
| dcmim2StatusRectEntry OBJECT-TYPE The rectifier to gather status from. | 1.3.6.1.4.1.318.1.1.9.4.2.2.1 | not-accessible | mandatory | |
| dcmim2StatusRectIndex OBJECT-TYPE The index to the DC powerplant rectifier. | 1.3.6.1.4.1.318.1.1.9.4.2.2.1.1 | INTEGER | read-only | mandatory |
| dcmim2StatusRectDevType OBJECT-TYPE This OID shows the rectifier device type. | 1.3.6.1.4.1.318.1.1.9.4.2.2.1.2 | INTEGER | read-only | mandatory |
| dcmim2StatusRectID OBJECT-TYPE This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers. | 1.3.6.1.4.1.318.1.1.9.4.2.2.1.3 | INTEGER | read-only | mandatory |
| dcmim2StatusRectPhyAddr OBJECT-TYPE This OID shows the rectifier physical address (the address on the bus). | 1.3.6.1.4.1.318.1.1.9.4.2.2.1.4 | INTEGER | read-only | mandatory |
| dcmim2StatusRectFail OBJECT-TYPE Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed. | 1.3.6.1.4.1.318.1.1.9.4.2.2.1.5 | INTEGER {statusTrue(1), statusFalse(2)} | read-only | mandatory |
| dcmim2StatusRectCurrent OBJECT-TYPE This OID shows the individual rectifier current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.9.4.2.2.1.6 | INTEGER | read-only | mandatory |
| dcmim2StatusBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.4.3 | |||
| dcmim2StatusBattFloatVolt OBJECT-TYPE Battery Float Voltage represented in thousandths of Volts (mV). | 1.3.6.1.4.1.318.1.1.9.4.3.1 | INTEGER | read-only | mandatory |
| dcmim2StatusBattCurrent OBJECT-TYPE Battery Current: This OID shows the battery current in thousandths of Amps (mA). | 1.3.6.1.4.1.318.1.1.9.4.3.2 | INTEGER | read-only | mandatory |
| dcmim2StatusBattTemp OBJECT-TYPE Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.9.4.3.3 | INTEGER | read-only | mandatory |
| dcmim2StatusBattMfgCapacity OBJECT-TYPE Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr). | 1.3.6.1.4.1.318.1.1.9.4.3.4 | INTEGER | read-only | mandatory |
| dcmim2StatusBattTestCapacity OBJECT-TYPE Battery capacity (Amp-Hour Size) as determined by the battery capacity test. Values are represented in thousandths of Amp hours (mAHr). | 1.3.6.1.4.1.318.1.1.9.4.3.5 | INTEGER | read-only | mandatory |
| dcmim2StatusBattFunctTestResult OBJECT-TYPE Results of the last battery functional test that was run. | 1.3.6.1.4.1.318.1.1.9.4.3.6 | INTEGER {functTestNotPerformed(1), functTestInProcess(2), functTestInterrupted(3), functTestPass(4), functTestFail(5)} | read-only | mandatory |
| dcmim2StatusBattCapacityTestResult OBJECT-TYPE Results of the last battery capacity test that was run. | 1.3.6.1.4.1.318.1.1.9.4.3.7 | INTEGER {capacityTestNotPerformed(1), capacityTestInProcess(2), capacityTestInterrupted(3), capacityTestPass(4), capacityTestFail(5)} | read-only | mandatory |
| dcmim2StatusLVD OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.4.4 | |||
| dcmim2StatusLVDTableSize OBJECT-TYPE The number of DC powerplant LVDs accessible by this IP address. | 1.3.6.1.4.1.318.1.1.9.4.4.1 | INTEGER | read-only | mandatory |
| dcmim2StatusLVDTable OBJECT-TYPE Allows for accessing the LVDs. The number of entries is contained in the dcmim2StatusLVDTableSize OID. | 1.3.6.1.4.1.318.1.1.9.4.4.2 | not-accessible | mandatory | |
| dcmim2StatusLVDEntry OBJECT-TYPE The LVD to access. | 1.3.6.1.4.1.318.1.1.9.4.4.2.1 | not-accessible | mandatory | |
| dcmim2StatusLVDIndex OBJECT-TYPE The index to the DC powerplant LVD. | 1.3.6.1.4.1.318.1.1.9.4.4.2.1.1 | INTEGER | read-only | mandatory |
| dcmim2StatusLVDState OBJECT-TYPE Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened. | 1.3.6.1.4.1.318.1.1.9.4.4.2.1.2 | INTEGER {statusClosed(1), statusOpened(2)} | read-only | mandatory |
| dcmim2StatusAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.9.4.5 | |||
| dcmim2StatusAlarmsTableSize OBJECT-TYPE The number of DC powerplant alarms viewable by this IP address. | 1.3.6.1.4.1.318.1.1.9.4.5.1 | INTEGER | read-only | mandatory |
| dcmim2StatusAlarmsTable OBJECT-TYPE Allows for accessing system alarms. The number of entries is contained in the dcmim2StatusAlarmsTableSize OID. | 1.3.6.1.4.1.318.1.1.9.4.5.2 | not-accessible | mandatory | |
| dcmim2StatusAlarmsEntry OBJECT-TYPE The alarm to display. | 1.3.6.1.4.1.318.1.1.9.4.5.2.1 | not-accessible | mandatory | |
| dcmim2StatusAlarmsIndex OBJECT-TYPE The index of the system alarm. | 1.3.6.1.4.1.318.1.1.9.4.5.2.1.1 | INTEGER | read-only | mandatory |
| dcmim2StatusAlarmsText OBJECT-TYPE The 16 character text describing the active alarm condition. | 1.3.6.1.4.1.318.1.1.9.4.5.2.1.2 | DisplayString | read-only | mandatory |
| environmentalMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10 | |||
| external OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.1 | |||
| emIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.1.1 | |||
| emIdentFirmwareRevision OBJECT-TYPE The firmware revision of the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.1.1.1 | DisplayString | read-only | mandatory |
| emConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.1.2 | |||
| emConfigProbesNumProbes OBJECT-TYPE The number of temperature and humidity probes available. | 1.3.6.1.4.1.318.1.1.10.1.2.1 | INTEGER | read-only | mandatory |
| emConfigProbesTable OBJECT-TYPE A list of probes supported by the Environmental Monitor and their configurations. | 1.3.6.1.4.1.318.1.1.10.1.2.2 | not-accessible | mandatory | |
| emConfigProbesEntry OBJECT-TYPE The Environmental Monitor probe configurations. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1 | not-accessible | mandatory | |
| emConfigProbeNumber OBJECT-TYPE The index into an Environmental Monitor probe entry. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.1 | INTEGER | read-only | mandatory |
| emConfigProbeName OBJECT-TYPE A descriptive name of the probe set by the user, possibly denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.2 | DisplayString | read-write | mandatory |
| emConfigProbeHighTempThreshold OBJECT-TYPE The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.3 | INTEGER | read-write | mandatory |
| emConfigProbeLowTempThreshold OBJECT-TYPE The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.4 | INTEGER | read-write | mandatory |
| emConfigProbeTempUnits OBJECT-TYPE The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.5 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| emConfigProbeHighHumidThreshold OBJECT-TYPE The high humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.6 | INTEGER | read-write | mandatory |
| emConfigProbeLowHumidThreshold OBJECT-TYPE The low humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.7 | INTEGER | read-write | mandatory |
| emConfigProbeHighTempEnable OBJECT-TYPE The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.8 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeLowTempEnable OBJECT-TYPE The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.9 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeHighHumidEnable OBJECT-TYPE The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.10 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeLowHumidEnable OBJECT-TYPE The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.11 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeMaxTempThreshold OBJECT-TYPE The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.12 | INTEGER | read-write | mandatory |
| emConfigProbeMinTempThreshold OBJECT-TYPE The minimum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.13 | INTEGER | read-write | mandatory |
| emConfigProbeMaxHumidThreshold OBJECT-TYPE The maximun humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.14 | INTEGER | read-write | mandatory |
| emConfigProbeMinHumidThreshold OBJECT-TYPE The minimum humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.15 | INTEGER | read-write | mandatory |
| emConfigProbeMaxTempEnable OBJECT-TYPE The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.16 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeMinTempEnable OBJECT-TYPE The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.17 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeMaxHumidEnable OBJECT-TYPE The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.18 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeMinHumidEnable OBJECT-TYPE The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.19 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigProbeTempHysteresis OBJECT-TYPE The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.20 | INTEGER | read-write | mandatory |
| emConfigProbeHumidHysteresis OBJECT-TYPE The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.21 | INTEGER | read-write | mandatory |
| emConfigProbeLocation OBJECT-TYPE A string describing the location of the probe. | 1.3.6.1.4.1.318.1.1.10.1.2.2.1.22 | DisplayString | read-write | mandatory |
| emConfigContactsNumContacts OBJECT-TYPE The number of contacts supported by the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.1.2.3 | INTEGER | read-only | mandatory |
| emConfigContactsTable OBJECT-TYPE A list of contacts supported by the Environmental Monitor and their configurations. | 1.3.6.1.4.1.318.1.1.10.1.2.4 | not-accessible | mandatory | |
| emConfigContactsEntry OBJECT-TYPE The Environmental Monitor contact configurations. | 1.3.6.1.4.1.318.1.1.10.1.2.4.1 | not-accessible | mandatory | |
| emConfigContactNumber OBJECT-TYPE The index of an Environmental Monitor contact. | 1.3.6.1.4.1.318.1.1.10.1.2.4.1.1 | INTEGER | read-only | mandatory |
| emConfigContactName OBJECT-TYPE A descriptive name for an Environmental Monitor contact set by the user, possibly denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.1.2.4.1.2 | DisplayString | read-write | mandatory |
| emConfigContactEnable OBJECT-TYPE An Environmental Monitor contact alarm enable/disable. No alarm will be generated if the contact is disabled(1). An alarm will be generated if the contact is enabled(2) and the contact has been faulted. | 1.3.6.1.4.1.318.1.1.10.1.2.4.1.3 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| emConfigContactSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.1.2.4.1.4 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| emConfigContactNormalState OBJECT-TYPE The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2). | 1.3.6.1.4.1.318.1.1.10.1.2.4.1.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| emConfigContactLocation OBJECT-TYPE A descriptive label for the contact denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.1.2.4.1.6 | DisplayString | read-write | mandatory |
| emStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.1.3 | |||
| emStatusCommStatus OBJECT-TYPE The communication status between the agent and the Environmental Monitor. noComm(1), Communication has never been established. comm(2), Communication has been established. commLost(3), Communication was established, but was lost. | 1.3.6.1.4.1.318.1.1.10.1.3.1 | INTEGER {noComm(1), comm(2), commLost(3)} | read-only | mandatory |
| emStatusProbesNumProbes OBJECT-TYPE The number of available probes on the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.1.3.2 | INTEGER | read-only | mandatory |
| emStatusProbesTable OBJECT-TYPE A list of probes supported by the Environmental Monitor and their status. | 1.3.6.1.4.1.318.1.1.10.1.3.3 | not-accessible | mandatory | |
| emStatusProbesEntry OBJECT-TYPE The status of the probe. | 1.3.6.1.4.1.318.1.1.10.1.3.3.1 | not-accessible | mandatory | |
| emStatusProbeNumber OBJECT-TYPE The index of the probe. | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.1 | INTEGER | read-only | mandatory |
| emStatusProbeName OBJECT-TYPE A descriptive name for the probe set by the user, possibly denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.2 | DisplayString | read-only | mandatory |
| emStatusProbeStatus OBJECT-TYPE The connected status of the probe, either disconnected(1) or connected(2). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.3 | INTEGER {disconnected(1), connected(2)} | read-only | mandatory |
| emStatusProbeCurrentTemp OBJECT-TYPE The current temperature reading from the probe displayed in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.4 | INTEGER | read-only | mandatory |
| emStatusProbeTempUnits OBJECT-TYPE The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.5 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| emStatusProbeCurrentHumid OBJECT-TYPE The current humidity reading from the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.6 | INTEGER | read-only | mandatory |
| emStatusProbeHighTempViolation OBJECT-TYPE The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to the high temperature threshold value, the 'emConfigProbeHighTempThreshold' OID, and the value of the 'emConfigProbeHighTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeHighTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.7 | INTEGER {noViolation(1), highTempViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeLowTempViolation OBJECT-TYPE The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to the low temperature threshold value, the 'emConfigProbeLowTempThreshold' OID, and the value of the 'emConfigProbeLowTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeLowTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.8 | INTEGER {noViolation(1), lowTempViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeHighHumidViolation OBJECT-TYPE The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the high humidity threshold value, the 'emConfigProbeHighHumidThreshold' OID, and the value of the 'emConfigProbeHighHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeHighHumidEnable' OID is disabled, this OID will show disabled(3) | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.9 | INTEGER {noViolation(1), highHumidViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeLowHumidViolation OBJECT-TYPE The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the low humidity threshold value, the 'emConfigProbeLowHumidThreshold' OID, and the value of the 'emConfigProbeLowHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeLowHumidEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.10 | INTEGER {noViolation(1), lowHumidViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeMaxTempViolation OBJECT-TYPE The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to the maximun temperature threshold value, the 'emConfigProbeMaxTempThreshold' OID, and the value of the 'emConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMaxTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.11 | INTEGER {noViolation(1), maxTempViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeMinTempViolation OBJECT-TYPE The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to the minimum temperature threshold value, the 'emConfigProbeMinTempThreshold' OID, and the value of the 'emConfigProbeMinTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMinTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.12 | INTEGER {noViolation(1), minTempViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeMaxHumidViolation OBJECT-TYPE The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the maximum humidity threshold value, the 'emConfigProbeMaxHumidThreshold' OID, and the value of the 'emConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMaxHumidEnable' OID is disabled, this OID will show disabled(3) | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.13 | INTEGER {noViolation(1), maxHumidViolation(2), disabled(3)} | read-only | mandatory |
| emStatusProbeMinHumidViolation OBJECT-TYPE The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the minimum humidity threshold value, the 'emConfigProbeMinHumidThreshold' OID, and the value of the 'emConfigProbeMinHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMinHumidEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.3.1.14 | INTEGER {noViolation(1), minHumidViolation(2), disabled(3)} | read-only | mandatory |
| emStatusContactsNumContacts OBJECT-TYPE The number of contacts supported by the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.1.3.4 | INTEGER | read-only | mandatory |
| emStatusContactsTable OBJECT-TYPE A list of contacts supported by the Environmental Monitor and their status. | 1.3.6.1.4.1.318.1.1.10.1.3.5 | not-accessible | mandatory | |
| emStatusContactsEntry OBJECT-TYPE The status of the contact. | 1.3.6.1.4.1.318.1.1.10.1.3.5.1 | not-accessible | mandatory | |
| emStatusContactNumber OBJECT-TYPE The index of the Environmental Monitor contact. | 1.3.6.1.4.1.318.1.1.10.1.3.5.1.1 | INTEGER | read-only | mandatory |
| emStatusContactName OBJECT-TYPE A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.1.3.5.1.2 | DisplayString | read-only | mandatory |
| emStatusContactStatus OBJECT-TYPE The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'emConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is faulted and the 'emContactEnable' OID is enabled. If the 'emConfigContactEnable' OID is disabled, the status will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.1.3.5.1.3 | INTEGER {noFault(1), fault(2), disabled(3)} | read-only | mandatory |
| integrated OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.2 | |||
| iemIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.2.1 | |||
| iemIdentHardwareRevision OBJECT-TYPE The hardware revision of the Integrated Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.2.1.1 | DisplayString | read-only | mandatory |
| iemConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.2.2 | |||
| iemConfigProbesNumProbes OBJECT-TYPE The number of temperature and humidity probes available. | 1.3.6.1.4.1.318.1.1.10.2.2.1 | INTEGER | read-only | mandatory |
| iemConfigProbesTable OBJECT-TYPE A list of probes supported by the Environmental Monitor and their configurations. | 1.3.6.1.4.1.318.1.1.10.2.2.2 | not-accessible | mandatory | |
| iemConfigProbesEntry OBJECT-TYPE The Environmental Monitor probe configurations. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1 | not-accessible | mandatory | |
| iemConfigProbeNumber OBJECT-TYPE The index to a Environmental Monitor probe entry. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.1 | INTEGER | read-only | mandatory |
| iemConfigProbeName OBJECT-TYPE A descriptive name for the probe set by the user, possibly denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.2 | DisplayString | read-write | mandatory |
| iemConfigProbeHighTempThreshold OBJECT-TYPE The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.3 | INTEGER | read-write | mandatory |
| iemConfigProbeLowTempThreshold OBJECT-TYPE The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.4 | INTEGER | read-write | mandatory |
| iemConfigProbeTempUnits OBJECT-TYPE The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.5 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| iemConfigProbeHighHumidThreshold OBJECT-TYPE The high humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.6 | INTEGER | read-write | mandatory |
| iemConfigProbeLowHumidThreshold OBJECT-TYPE The low humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.7 | INTEGER | read-write | mandatory |
| iemConfigProbeHighTempEnable OBJECT-TYPE The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.8 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeLowTempEnable OBJECT-TYPE The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.9 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeHighHumidEnable OBJECT-TYPE The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.10 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeLowHumidEnable OBJECT-TYPE The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.11 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeMaxTempThreshold OBJECT-TYPE The maximun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.12 | INTEGER | read-write | mandatory |
| iemConfigProbeMinTempThreshold OBJECT-TYPE The minimun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.13 | INTEGER | read-write | mandatory |
| iemConfigProbeMaxHumidThreshold OBJECT-TYPE The maximum humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.14 | INTEGER | read-write | mandatory |
| iemConfigProbeMinHumidThreshold OBJECT-TYPE The minimum humidity alarm threshold for the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.15 | INTEGER | read-write | mandatory |
| iemConfigProbeMaxTempEnable OBJECT-TYPE The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.16 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeMinTempEnable OBJECT-TYPE The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.17 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeMaxHumidEnable OBJECT-TYPE The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.18 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeMinHumidEnable OBJECT-TYPE The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.19 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigProbeTempHysteresis OBJECT-TYPE The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.20 | INTEGER | read-write | mandatory |
| iemConfigProbeHumidHysteresis OBJECT-TYPE The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.21 | INTEGER | read-write | mandatory |
| iemConfigProbeLocation OBJECT-TYPE A string describing the location of the probe. | 1.3.6.1.4.1.318.1.1.10.2.2.2.1.22 | DisplayString | read-write | mandatory |
| iemConfigContactsNumContacts OBJECT-TYPE The number of contacts available on the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.2.2.3 | INTEGER | read-only | mandatory |
| iemConfigContactsTable OBJECT-TYPE A list of contacts supported by the Environmental Monitor and their configurations. | 1.3.6.1.4.1.318.1.1.10.2.2.4 | not-accessible | mandatory | |
| iemConfigContactsEntry OBJECT-TYPE The Environmental Monitor contact configurations. | 1.3.6.1.4.1.318.1.1.10.2.2.4.1 | not-accessible | mandatory | |
| iemConfigContactNumber OBJECT-TYPE The index of an Environmental Monitor contact. | 1.3.6.1.4.1.318.1.1.10.2.2.4.1.1 | INTEGER | read-only | mandatory |
| iemConfigContactName OBJECT-TYPE A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.2.2.4.1.2 | DisplayString | read-write | mandatory |
| iemConfigContactEnable OBJECT-TYPE An Environmental Monitor contact alarm enable/disable. | 1.3.6.1.4.1.318.1.1.10.2.2.4.1.3 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| iemConfigContactSeverity OBJECT-TYPE The severtity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). NOTE: informational(3) is deprecated (and no longer valid) for this OID. | 1.3.6.1.4.1.318.1.1.10.2.2.4.1.4 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| iemConfigContactNormalState OBJECT-TYPE The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2). | 1.3.6.1.4.1.318.1.1.10.2.2.4.1.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| iemConfigContactLocation OBJECT-TYPE A descriptive label for the contact denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.2.2.4.1.6 | DisplayString | read-write | mandatory |
| iemConfigConfigRelaysNumRelays OBJECT-TYPE The number of output relays supported by the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.2.2.5 | INTEGER | read-only | mandatory |
| iemConfigRelaysTable OBJECT-TYPE A list of output relays supported by the Environmental Monitor and their configurations. | 1.3.6.1.4.1.318.1.1.10.2.2.6 | not-accessible | mandatory | |
| iemConfigRelaysEntry OBJECT-TYPE The Environmental Monitor output relay configurations. | 1.3.6.1.4.1.318.1.1.10.2.2.6.1 | not-accessible | mandatory | |
| iemConfigRelayNumber OBJECT-TYPE The index of an Environmental Monitor output relay. | 1.3.6.1.4.1.318.1.1.10.2.2.6.1.1 | INTEGER | read-only | mandatory |
| iemConfigRelayName OBJECT-TYPE A descriptive name of an Environmental Monitor output relay, set by the user, describing its location or purpose. | 1.3.6.1.4.1.318.1.1.10.2.2.6.1.2 | DisplayString | read-write | mandatory |
| iemConfigRelayNormalState OBJECT-TYPE The normal state (non-fault state) of an Environmental Monitor output relay, either open(1) or closed(2). | 1.3.6.1.4.1.318.1.1.10.2.2.6.1.3 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| iemConfigRelayFaultCondition OBJECT-TYPE The fault condition used to activate the output relay. | 1.3.6.1.4.1.318.1.1.10.2.2.6.1.4 | INTEGER | read-write | mandatory |
| iemStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.2.3 | |||
| iemStatusProbesNumProbes OBJECT-TYPE The number of available probes on the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.2.3.1 | INTEGER | read-only | mandatory |
| iemStatusProbesTable OBJECT-TYPE A list of probes supported by the Environmental Monitor and their status. | 1.3.6.1.4.1.318.1.1.10.2.3.2 | not-accessible | mandatory | |
| iemStatusProbesEntry OBJECT-TYPE The status of the probe. | 1.3.6.1.4.1.318.1.1.10.2.3.2.1 | not-accessible | mandatory | |
| iemStatusProbeNumber OBJECT-TYPE The index of the probe. | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.1 | INTEGER | read-only | mandatory |
| iemStatusProbeName OBJECT-TYPE A descriptive name for the probe set by the user. | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.2 | DisplayString | read-only | mandatory |
| iemStatusProbeStatus OBJECT-TYPE The connected status of the probe, either disconnected(1) or connected(2). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.3 | INTEGER {disconnected(1), connected(2)} | read-only | mandatory |
| iemStatusProbeCurrentTemp OBJECT-TYPE The current temperature reading from the probe displayed in the units shown in the 'iemStatusProbeTempUnits' OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.4 | INTEGER | read-only | mandatory |
| iemStatusProbeTempUnits OBJECT-TYPE The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.5 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| iemStatusProbeCurrentHumid OBJECT-TYPE The current humidity reading from the probe in percent relative humidity. | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.6 | INTEGER | read-only | mandatory |
| iemStatusProbeHighTempViolation OBJECT-TYPE The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to the high temperature threshold value, the 'iemConfigProbeHighTempThreshold' OID, and the value of the 'iemConfigProbeHighTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeHighTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.7 | INTEGER {noViolation(1), highTempViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeLowTempViolation OBJECT-TYPE The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to the low temperature threshold value, the 'iemConfigProbeLowTempThreshold' OID, and the value of the 'iemPConfigrobeLowTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeLowTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.8 | INTEGER {noViolation(1), lowTempViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeHighHumidViolation OBJECT-TYPE The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the high humidity threshold value, the 'iemConfigProbeHighHumidThreshold' OID, and the value of the 'iemConfigProbeHighHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeHighHumidEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.9 | INTEGER {noViolation(1), highHumidViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeLowHumidViolation OBJECT-TYPE The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the low humidity threshold value, the 'iemConfigProbeLowHumidThreshold' OID, and the value of the 'iemConfigProbeLowHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeLowHumidEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.10 | INTEGER {noViolation(1), lowHumidViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeMaxTempViolation OBJECT-TYPE The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to the maximun temperature threshold value, the 'iemConfigProbeMaxTempThreshold' OID, and the value of the 'iemConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMaxTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.11 | INTEGER {noViolation(1), maxTempViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeMinTempViolation OBJECT-TYPE The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to the minimum temperature threshold value, the 'iemConfigProbeMinTempThreshold' OID, and the value of the 'iemConfigProbeMinTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMinTempEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.12 | INTEGER {noViolation(1), minTempViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeMaxHumidViolation OBJECT-TYPE The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the maximum humidity threshold value, the 'iemConfigProbeMaxHumidThreshold' OID, and the value of the 'iemConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMaxHumidEnable' OID is disabled, this OID will show disabled(3) | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.13 | INTEGER {noViolation(1), maxHumidViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeMinHumidViolation OBJECT-TYPE The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the minimum humidity threshold value, the 'iemConfigProbeMinHumidThreshold' OID, and the value of the 'iemConfigProbeMinHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMinHumidEnable' OID is disabled, this OID will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.14 | INTEGER {noViolation(1), minHumidViolation(2), disabled(3)} | read-only | mandatory |
| iemStatusProbeLocation OBJECT-TYPE A descriptive location for the probe set by the user. | 1.3.6.1.4.1.318.1.1.10.2.3.2.1.15 | DisplayString | read-only | mandatory |
| iemStatusContactsNumContacts OBJECT-TYPE The number of contacts supported on the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.2.3.3 | INTEGER | read-only | mandatory |
| iemStatusContactsTable OBJECT-TYPE A list of contacts supported by the Environmental Monitor and their status. | 1.3.6.1.4.1.318.1.1.10.2.3.4 | not-accessible | mandatory | |
| iemStatusContactsEntry OBJECT-TYPE The status of the contact. | 1.3.6.1.4.1.318.1.1.10.2.3.4.1 | not-accessible | mandatory | |
| iemStatusContactNumber OBJECT-TYPE The index of the Environmental Monitor contact. | 1.3.6.1.4.1.318.1.1.10.2.3.4.1.1 | INTEGER | read-only | mandatory |
| iemStatusContactName OBJECT-TYPE A descriptive name for the Environmental Monitor contact set by the user, denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.2.3.4.1.2 | DisplayString | read-only | mandatory |
| iemStatusContactStatus OBJECT-TYPE The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'iemConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is faulted and the 'iemConfigContactEnable' OID is enabled. If the 'iemConfigContactEnable' OID is disabled, the status will show disabled(3). | 1.3.6.1.4.1.318.1.1.10.2.3.4.1.3 | INTEGER {noFault(1), fault(2), disabled(3)} | read-only | mandatory |
| iemStatusRelaysNumRelays OBJECT-TYPE The number of output relays supported on the Environmental Monitor. | 1.3.6.1.4.1.318.1.1.10.2.3.6 | INTEGER | read-only | mandatory |
| iemStatusRelaysTable OBJECT-TYPE A list of output relays supported by the Environmental Monitor and their status. | 1.3.6.1.4.1.318.1.1.10.2.3.7 | not-accessible | mandatory | |
| iemStatusRelaysEntry OBJECT-TYPE The status of the relay. | 1.3.6.1.4.1.318.1.1.10.2.3.7.1 | not-accessible | mandatory | |
| iemStatusRelayNumber OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.10.2.3.7.1.1 | INTEGER | read-only | mandatory |
| iemStatusRelayName OBJECT-TYPE A descriptive name for the output relay set by the user, denoting its location or purpose. | 1.3.6.1.4.1.318.1.1.10.2.3.7.1.2 | DisplayString | read-only | mandatory |
| iemStatusRelayStatus OBJECT-TYPE The status of the output relay, either faultState(1) or normalState(2). | 1.3.6.1.4.1.318.1.1.10.2.3.7.1.3 | INTEGER {faultState(1), normalState(2)} | read-only | mandatory |
| envMgtSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3 | |||
| emsIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.1 | |||
| emsIdentEMSName OBJECT-TYPE A character string identifying the device. | 1.3.6.1.4.1.318.1.1.10.3.1.1 | DisplayString | read-only | mandatory |
| emsIdentProductNumber OBJECT-TYPE A character string identifying the model number of the device. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.10.3.1.2 | DisplayString | read-only | mandatory |
| emsIdentFirmwareRev OBJECT-TYPE The firmware revision of the device. | 1.3.6.1.4.1.318.1.1.10.3.1.3 | DisplayString | read-only | mandatory |
| emsIdentHardwareRev OBJECT-TYPE The hardware revision of the device. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.10.3.1.4 | DisplayString | read-only | mandatory |
| emsIdentDateOfManufacture OBJECT-TYPE The date when the device was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.10.3.1.5 | DisplayString | read-only | mandatory |
| emsIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the device. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.10.3.1.6 | DisplayString | read-only | mandatory |
| emsOutputRelayControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.2 | |||
| emsOutputRelayControlTable OBJECT-TYPE Allows for control of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID. | 1.3.6.1.4.1.318.1.1.10.3.2.1 | not-accessible | mandatory | |
| emsOutputRelayControlEntry OBJECT-TYPE The output relays to control. | 1.3.6.1.4.1.318.1.1.10.3.2.1.1 | not-accessible | mandatory | |
| emsOutputRelayControlOutputRelayIndex OBJECT-TYPE The index to the output relay entry. | 1.3.6.1.4.1.318.1.1.10.3.2.1.1.1 | INTEGER | read-only | mandatory |
| emsOutputRelayControlOutputRelayName OBJECT-TYPE The name of the output relay. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.10.3.2.1.1.2 | DisplayString | read-only | mandatory |
| emsOutputRelayControlOutputRelayCommand OBJECT-TYPE Getting this variable will return the output relay state. If the output relay is closed, the immediateCloseEMS (1) value will be returned. If the output relay is open, the immediateOpenEMS (2) value will be returned. Setting this variable to immediateCloseEMS (1) will immediately close the relay. Setting this variable to immediateOpenEMS (2) will immediately open the relay. | 1.3.6.1.4.1.318.1.1.10.3.2.1.1.3 | INTEGER {immediateCloseEMS(1), immediateOpenEMS(2)} | read-write | mandatory |
| emsOutletControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.3 | |||
| emsOutletControlTable OBJECT-TYPE Allows for control of individual outlet switches. The number of entries is contained in the emsStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.10.3.3.1 | not-accessible | mandatory | |
| emsOutletControlEntry OBJECT-TYPE The outlets to control. | 1.3.6.1.4.1.318.1.1.10.3.3.1.1 | not-accessible | mandatory | |
| emsOutletControlOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.10.3.3.1.1.1 | INTEGER | read-only | mandatory |
| emsOutletControlOutletName OBJECT-TYPE The name of the outlet. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.10.3.3.1.1.2 | DisplayString | read-only | mandatory |
| emsOutletControlOutletCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOnEMS (1) value will be returned. If the outlet is off, the immediateOffEMS (2) value will be returned. Setting this variable to immediateOnEMS (1) will immediately turn the outlet on. Setting this variable to immediateOffEMS (2) will immediately turn the outlet off. | 1.3.6.1.4.1.318.1.1.10.3.3.1.1.3 | INTEGER {immediateOnEMS(1), immediateOffEMS(2)} | read-write | mandatory |
| emsSensorControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.4 | |||
| emsSensorControlTable OBJECT-TYPE Allows for control/reset of individual sensors. The number of entries is contained in the emsStatusSensorCount OID. | 1.3.6.1.4.1.318.1.1.10.3.4.1 | not-accessible | mandatory | |
| emsSensorControlEntry OBJECT-TYPE The sensors to control/reset. | 1.3.6.1.4.1.318.1.1.10.3.4.1.1 | not-accessible | mandatory | |
| emsSensorControlSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.4.1.1.1 | INTEGER | read-only | mandatory |
| emsSensorControlSensorSystemName OBJECT-TYPE The system name of the sensor. This describes the hardware system intent of this sensor. | 1.3.6.1.4.1.318.1.1.10.3.4.1.1.2 | DisplayString | read-only | mandatory |
| emsSensorControlSensorUserName OBJECT-TYPE The name of the sensor as given by the system user. | 1.3.6.1.4.1.318.1.1.10.3.4.1.1.3 | DisplayString | read-only | mandatory |
| emsSensorControlSensorCommand OBJECT-TYPE Getting this variable will return noCommandEMS(1). Setting this variable to resetCommandEMS(2) will issue a reset command to the sensor. Some sensors cannot be manually reset and will not be affected by this command. | 1.3.6.1.4.1.318.1.1.10.3.4.1.1.4 | INTEGER {noCommandEMS(1), resetCommandEMS(2)} | read-write | mandatory |
| emsAlarmDeviceControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.5 | |||
| emsAlarmDeviceControlTable OBJECT-TYPE Allows for control of individual alarm devices. Note: Some alarm devices are not controllable. The number of entries is contained in the emsStatusAlarmDeviceCount OID. | 1.3.6.1.4.1.318.1.1.10.3.5.1 | not-accessible | mandatory | |
| emsAlarmDeviceControlEntry OBJECT-TYPE The alarm devices to control. | 1.3.6.1.4.1.318.1.1.10.3.5.1.1 | not-accessible | mandatory | |
| emsAlarmDeviceControlDeviceIndex OBJECT-TYPE The index to the alarm device entry. | 1.3.6.1.4.1.318.1.1.10.3.5.1.1.1 | INTEGER | read-only | mandatory |
| emsAlarmDeviceControlDeviceName OBJECT-TYPE The name of the alarm device. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.10.3.5.1.1.2 | DisplayString | read-only | mandatory |
| emsAlarmDeviceControlDeviceCommand OBJECT-TYPE Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is not installed, the alarmDeviceNotInstalledEMS (3) value will be returned. Actions resulting from setting this variable are device-dependent. Setting this variable to alarmDeviceOnEMS (1) will turn that device (ex. Beacon) on. Setting this variable to alarmDeviceOffEMS (2) will turn that device off. | 1.3.6.1.4.1.318.1.1.10.3.5.1.1.3 | INTEGER {alarmDeviceOnEMS(1), alarmDeviceOffEMS(2), alarmDeviceNotInstalledEMS(3)} | read-write | mandatory |
| emsConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.6 | |||
| emsConfigName OBJECT-TYPE The name of the device. | 1.3.6.1.4.1.318.1.1.10.3.6.1 | DisplayString | read-write | mandatory |
| emsConfigCheckLogLight OBJECT-TYPE The setting of this OID determines the level of event that will trigger the check-log light on the EMS. This is not available on the EMU2. lightDisabled (1) disables the check-log light. lightOnInformational (2) lights check-log for any event of informational severity or above. lightOnWarning (3) lights check-log for any event of warning severity or above. lightOnSevere (4) lights check-log for any event of severe severity. | 1.3.6.1.4.1.318.1.1.10.3.6.2 | INTEGER {lightDisabled(1), lightOnInformational(2), lightOnWarning(3), lightOnSevere(4)} | read-write | mandatory |
| emsProbeConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.7 | |||
| emsProbeConfigTable OBJECT-TYPE Allows for configuration of individual probes. The number of entries is contained in the emsStatusProbeCount OID. | 1.3.6.1.4.1.318.1.1.10.3.7.1 | not-accessible | mandatory | |
| emsProbeConfigEntry OBJECT-TYPE The probes to configure. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1 | not-accessible | mandatory | |
| emsProbeConfigProbeIndex OBJECT-TYPE The index to the probe entry. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.1 | INTEGER | read-only | mandatory |
| emsProbeConfigProbeName OBJECT-TYPE The name of the probe. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.2 | DisplayString | read-write | mandatory |
| emsProbeConfigProbeHighTempThresh OBJECT-TYPE Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.3 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeLowTempThresh OBJECT-TYPE Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.4 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeHighHumidityThresh OBJECT-TYPE Probe high humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.5 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeLowHumidityThresh OBJECT-TYPE Probe low humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.6 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeMaxTempThresh OBJECT-TYPE Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.7 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeMinTempThresh OBJECT-TYPE Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.8 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeDeltaTemp OBJECT-TYPE Probe delta temperature. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.9 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeMaxHumidityThresh OBJECT-TYPE Probe maximum humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.10 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeMinHumidityThresh OBJECT-TYPE Probe minimum humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.11 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeDeltaHumidity OBJECT-TYPE Probe delta humidity. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.12 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeSTIncTempVariance OBJECT-TYPE Probe short-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.13 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeSTIncTempTime OBJECT-TYPE Probe short-term increasing temperature time used for rate of change alarms. Values are represented in whole number minutes. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.14 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeSTDecTempVariance OBJECT-TYPE Probe short-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.15 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeSTDecTempTime OBJECT-TYPE Probe short-term decreasing temperature time used for rate of change alarms. Values are represented in whole number minutes. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.16 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeLTIncTempVariance OBJECT-TYPE Probe long-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.17 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeLTIncTempTime OBJECT-TYPE Probe long-term increasing temperature time used for rate of change alarms. Values are represented in whole number hours. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.18 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeLTDecTempVariance OBJECT-TYPE Probe long-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.19 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeLTDecTempTime OBJECT-TYPE Probe long-term decreasing temperature time used for rate of change alarms. Values are represented in whole number hours. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.20 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeMaxVoltThresh OBJECT-TYPE Probe maximum voltage threshold in Volts. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.21 | INTEGER | read-write | mandatory |
| emsProbeConfigProbeMinVoltThresh OBJECT-TYPE Probe minimum voltage threshold in Volts. | 1.3.6.1.4.1.318.1.1.10.3.7.1.1.22 | INTEGER | read-write | mandatory |
| emsInputContactConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.8 | |||
| emsInputContactConfigTable OBJECT-TYPE Allows for configuration of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID. | 1.3.6.1.4.1.318.1.1.10.3.8.1 | not-accessible | mandatory | |
| emsInputContactConfigEntry OBJECT-TYPE The input contacts to configure. | 1.3.6.1.4.1.318.1.1.10.3.8.1.1 | not-accessible | mandatory | |
| emsInputContactConfigInputContactIndex OBJECT-TYPE The index to the input contact entry. | 1.3.6.1.4.1.318.1.1.10.3.8.1.1.1 | INTEGER | read-only | mandatory |
| emsInputContactConfigInputContactName OBJECT-TYPE The name of the input contact. | 1.3.6.1.4.1.318.1.1.10.3.8.1.1.2 | DisplayString | read-write | mandatory |
| emsInputContactConfigInputContactNormalState OBJECT-TYPE Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the input contact | 1.3.6.1.4.1.318.1.1.10.3.8.1.1.3 | INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)} | read-write | mandatory |
| emsOutputRelayConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.9 | |||
| emsOutputRelayConfigTable OBJECT-TYPE Allows for configuration of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID. | 1.3.6.1.4.1.318.1.1.10.3.9.1 | not-accessible | mandatory | |
| emsOutputRelayConfigEntry OBJECT-TYPE The output relays to configure. | 1.3.6.1.4.1.318.1.1.10.3.9.1.1 | not-accessible | mandatory | |
| emsOutputRelayConfigOutputRelayIndex OBJECT-TYPE The index to the output relay entry. | 1.3.6.1.4.1.318.1.1.10.3.9.1.1.1 | INTEGER | read-only | mandatory |
| emsOutputRelayConfigOutputRelayName OBJECT-TYPE The name of the output relay. | 1.3.6.1.4.1.318.1.1.10.3.9.1.1.2 | DisplayString | read-write | mandatory |
| emsOutputRelayConfigOutputRelayNormalState OBJECT-TYPE Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the output relay | 1.3.6.1.4.1.318.1.1.10.3.9.1.1.3 | INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)} | read-write | mandatory |
| emsOutletConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.10 | |||
| emsOutletConfigTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the emsStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.10.3.10.1 | not-accessible | mandatory | |
| emsOutletConfigEntry OBJECT-TYPE The outlets to configure. | 1.3.6.1.4.1.318.1.1.10.3.10.1.1 | not-accessible | mandatory | |
| emsOutletConfigOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.10.3.10.1.1.1 | INTEGER | read-only | mandatory |
| emsOutletConfigOutletName OBJECT-TYPE The name of the outlet. | 1.3.6.1.4.1.318.1.1.10.3.10.1.1.2 | DisplayString | read-write | mandatory |
| emsOutletConfigOutletNormalState OBJECT-TYPE Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned. Setting this variable will change the normal state of the outlet | 1.3.6.1.4.1.318.1.1.10.3.10.1.1.3 | INTEGER {normallyOnEMS(1), normallyOffEMS(2)} | read-write | mandatory |
| emsSensorConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.11 | |||
| emsSensorConfigTable OBJECT-TYPE Allows for configuration of individual sensors. The number of entries is contained in the emsStatusSensorCount OID. | 1.3.6.1.4.1.318.1.1.10.3.11.1 | not-accessible | mandatory | |
| emsSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.3.11.1.1 | not-accessible | mandatory | |
| emsSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.11.1.1.1 | INTEGER | read-only | mandatory |
| emsSensorConfigSensorSystemName OBJECT-TYPE The system name of the sensor. This describes the hardware system intent of this sensor. | 1.3.6.1.4.1.318.1.1.10.3.11.1.1.2 | DisplayString | read-only | mandatory |
| emsSensorConfigSensorUserName OBJECT-TYPE The name of the sensor as given by the system user. | 1.3.6.1.4.1.318.1.1.10.3.11.1.1.3 | DisplayString | read-write | mandatory |
| emsSensorConfigSensorNormalState OBJECT-TYPE Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the sensor. Note: Only the AUX sensor in the EMS has a configurable Normal State | 1.3.6.1.4.1.318.1.1.10.3.11.1.1.4 | INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)} | read-write | mandatory |
| emsSensorConfigSensorAlarmDelay OBJECT-TYPE The delay (in seconds) after a sensor detects an alarm condition before the condition is reported. | 1.3.6.1.4.1.318.1.1.10.3.11.1.1.5 | INTEGER | read-write | mandatory |
| emsStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.12 | |||
| emsStatusEMSName OBJECT-TYPE A character string identifying the device. | 1.3.6.1.4.1.318.1.1.10.3.12.1 | DisplayString | read-only | mandatory |
| emsStatusCommStatus OBJECT-TYPE The communication status between the agent and the device. noComm(1), Communication has never been established. comm(2), Communication has been established. commLost(3), Communication was established, but was lost. | 1.3.6.1.4.1.318.1.1.10.3.12.2 | INTEGER {noComm(1), comm(2), commLost(3)} | read-only | mandatory |
| emsStatusProbeCount OBJECT-TYPE The total number of T/H probes (both local and remote) that is supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.3 | INTEGER | read-only | mandatory |
| emsStatusInputContactCount OBJECT-TYPE The total number of Input Contacts that is supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.4 | INTEGER | read-only | mandatory |
| emsStatusOutputRelayCount OBJECT-TYPE The total number of Output Relays that is supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.5 | INTEGER | read-only | mandatory |
| emsStatusOutletCount OBJECT-TYPE The total number of AC Outlets that is supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.6 | INTEGER | read-only | mandatory |
| emsStatusSensorCount OBJECT-TYPE The total number of Sensors that is supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.7 | INTEGER | read-only | mandatory |
| emsStatusAlinkAruDeviceCount OBJECT-TYPE The total number of remote Aru's supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.8 | INTEGER | read-only | mandatory |
| emsStatusAlinkProbeDeviceCount OBJECT-TYPE The total number of remote T/H probes supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.9 | INTEGER | read-only | mandatory |
| emsStatusAlarmDeviceCount OBJECT-TYPE The number of alarm devices supported by this device. | 1.3.6.1.4.1.318.1.1.10.3.12.10 | INTEGER | read-only | mandatory |
| emsStatusSysTempUnits OBJECT-TYPE The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.10.3.12.11 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| emsStatusCheckLogLight OBJECT-TYPE The status of the check-log light on the device. For the EMU2, this will always indicate lightOff(1). lightOff (1) indicates the light is off (no new log entries). lightOn (2) indicates the light is on (new log entries present). | 1.3.6.1.4.1.318.1.1.10.3.12.12 | INTEGER {lightOff(1), lightOn(2)} | read-only | mandatory |
| emsStatusHardwareStatus OBJECT-TYPE The status of the EMS hardware. This integer should be interpreted as a bit map, with each bit representing the presence or absence of a specific hardware error condition. 0 indicates there are no error conditions detected in the EMS hardware. 1 indicates a Current Limit error condition related to the Alink port. 2 indicates incorrect hardware is plugged into an EMS port. 3 indicates that both of these error conditions are present. | 1.3.6.1.4.1.318.1.1.10.3.12.13 | INTEGER | read-only | mandatory |
| emsProbeStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.13 | |||
| emsProbeStatusTable OBJECT-TYPE Allows for access of individual probes. The number of entries is contained in the emsStatusProbeCount OID. | 1.3.6.1.4.1.318.1.1.10.3.13.1 | not-accessible | mandatory | |
| emsProbeStatusEntry OBJECT-TYPE The probes to access. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1 | not-accessible | mandatory | |
| emsProbeStatusProbeIndex OBJECT-TYPE The index to the probe entry. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.1 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeName OBJECT-TYPE The name of the probe. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.2 | DisplayString | read-only | mandatory |
| emsProbeStatusProbeTemperature OBJECT-TYPE Probe temperature reading. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.3 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeHighTempThresh OBJECT-TYPE Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.4 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeLowTempThresh OBJECT-TYPE Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.5 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeHumidity OBJECT-TYPE Probe humidity reading. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.6 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeHighHumidityThresh OBJECT-TYPE Probe high humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.7 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeLowHumidityThresh OBJECT-TYPE Probe low humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.8 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeSerialNumber OBJECT-TYPE A label indicating the type (Local[L] or Remote[R]) and Number of the probe. For example, the first local probe would be L1 and the third remote probe would be R3. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.9 | DisplayString | read-only | mandatory |
| emsProbeStatusProbeCommStatus OBJECT-TYPE The state of communications to the probe. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no longer. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.10 | INTEGER {commsNeverDiscovered(1), commsEstablished(2), commsLost(3)} | read-only | mandatory |
| emsProbeStatusProbeAlarmStatus OBJECT-TYPE The alarm status of the probe. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Short-term increasing temperature rate exceeded. 6 0x0020 Short-term decreasing temperature rate exceeded. 7 0x0040 Long-term increasing temperature rate exceeded. 8 0x0080 Long-term decreasing temperature rate exceeded. 9 0x0100 Maximum humidity exceeded. 10 0x0200 High humidity exceeded. 11 0x0400 Low humidity exceeded. 12 0x0800 Minimum humidity exceeded. 13 0x1000 Maximum voltage exceeded. 14 0x2000 Minimum voltage exceeded. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.11 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeMaxTempThresh OBJECT-TYPE Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.12 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeMinTempThresh OBJECT-TYPE Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.13 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeMaxHumidityThresh OBJECT-TYPE Probe maximum humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.14 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeMinHumidityThresh OBJECT-TYPE Probe minimum humidity threshold. Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.15 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeVoltage OBJECT-TYPE Probe voltage reading. Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.16 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeMaxVoltThresh OBJECT-TYPE Probe maximum voltage threshold in Volts. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.17 | INTEGER | read-only | mandatory |
| emsProbeStatusProbeMinVoltThresh OBJECT-TYPE Probe minimum voltage threshold in Volts. | 1.3.6.1.4.1.318.1.1.10.3.13.1.1.18 | INTEGER | read-only | mandatory |
| emsInputContactStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.14 | |||
| emsInputContactStatusTable OBJECT-TYPE Allows for access of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID. | 1.3.6.1.4.1.318.1.1.10.3.14.1 | not-accessible | mandatory | |
| emsInputContactStatusEntry OBJECT-TYPE The input contacts to access. | 1.3.6.1.4.1.318.1.1.10.3.14.1.1 | not-accessible | mandatory | |
| emsInputContactStatusInputContactIndex OBJECT-TYPE The index to the input contact entry. | 1.3.6.1.4.1.318.1.1.10.3.14.1.1.1 | INTEGER | read-only | mandatory |
| emsInputContactStatusInputContactName OBJECT-TYPE The name of the input contact. | 1.3.6.1.4.1.318.1.1.10.3.14.1.1.2 | DisplayString | read-only | mandatory |
| emsInputContactStatusInputContactState OBJECT-TYPE Getting this variable will return the state of the input contact. If the input contact is closed, the contactClosedEMS (1) value will be returned. If the input contact state is open, the contactOpenEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.14.1.1.3 | INTEGER {contactClosedEMS(1), contactOpenEMS(2)} | read-only | mandatory |
| emsInputContactStatusInputContactNormalState OBJECT-TYPE Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.14.1.1.4 | INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)} | read-only | mandatory |
| emsOutputRelayStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.15 | |||
| emsOutputRelayStatusTable OBJECT-TYPE Allows for access of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID. | 1.3.6.1.4.1.318.1.1.10.3.15.1 | not-accessible | mandatory | |
| emsOutputRelayStatusEntry OBJECT-TYPE The output relays to access. | 1.3.6.1.4.1.318.1.1.10.3.15.1.1 | not-accessible | mandatory | |
| emsOutputRelayStatusOutputRelayIndex OBJECT-TYPE The index to the output relay entry. | 1.3.6.1.4.1.318.1.1.10.3.15.1.1.1 | INTEGER | read-only | mandatory |
| emsOutputRelayStatusOutputRelayName OBJECT-TYPE The name of the output relay. | 1.3.6.1.4.1.318.1.1.10.3.15.1.1.2 | DisplayString | read-only | mandatory |
| emsOutputRelayStatusOutputRelayState OBJECT-TYPE Getting this variable will return the state of the output relay. If the output relay is closed, the relayClosedEMS (1) value will be returned. If the output relay is open, the relayOpenEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.15.1.1.3 | INTEGER {relayClosedEMS(1), relayOpenEMS(2)} | read-only | mandatory |
| emsOutputRelayStatusOutputRelayNormalState OBJECT-TYPE Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.15.1.1.4 | INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)} | read-only | mandatory |
| emsOutletStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.16 | |||
| emsOutletStatusTable OBJECT-TYPE Allows for access of individual outlets. The number of entries is contained in the emsStatusOutletCount OID. | 1.3.6.1.4.1.318.1.1.10.3.16.1 | not-accessible | mandatory | |
| emsOutletStatusEntry OBJECT-TYPE The outlets to access. | 1.3.6.1.4.1.318.1.1.10.3.16.1.1 | not-accessible | mandatory | |
| emsOutletStatusOutletIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.10.3.16.1.1.1 | INTEGER | read-only | mandatory |
| emsOutletStatusOutletName OBJECT-TYPE The name of the outlet. | 1.3.6.1.4.1.318.1.1.10.3.16.1.1.2 | DisplayString | read-only | mandatory |
| emsOutletStatusOutletState OBJECT-TYPE Getting this variable will return the state of the outlet. If the outlet is on, the outletOnEMS (1) value will be returned. If the outlet is off, the outletOffEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.16.1.1.3 | INTEGER {outletOnEMS(1), outletOffEMS(2)} | read-only | mandatory |
| emsOutletStatusOutletNormalState OBJECT-TYPE Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.16.1.1.4 | INTEGER {normallyOnEMS(1), normallyOffEMS(2)} | read-only | mandatory |
| emsAlarmDeviceStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.17 | |||
| emsAlarmDeviceStatusTable OBJECT-TYPE Allows for access of individual alarm devices. The number of entries is contained in the emsStatusAlarmDeviceCount OID. | 1.3.6.1.4.1.318.1.1.10.3.17.1 | not-accessible | mandatory | |
| emsAlarmDeviceStatusEntry OBJECT-TYPE The alarm devices to access. | 1.3.6.1.4.1.318.1.1.10.3.17.1.1 | not-accessible | mandatory | |
| emsAlarmDeviceStatusDeviceIndex OBJECT-TYPE The index to the alarm device entry. | 1.3.6.1.4.1.318.1.1.10.3.17.1.1.1 | INTEGER | read-only | mandatory |
| emsAlarmDeviceStatusDeviceName OBJECT-TYPE The name of the alarm device. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.10.3.17.1.1.2 | DisplayString | read-only | mandatory |
| emsAlarmDeviceStatusDeviceState OBJECT-TYPE Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is not installed, the alarmDeviceNotInstalledEMS (3) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.17.1.1.3 | INTEGER {alarmDeviceOnEMS(1), alarmDeviceOffEMS(2), alarmDeviceNotInstalledEMS(3)} | read-only | mandatory |
| emsSensorStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.18 | |||
| emsSensorStatusTable OBJECT-TYPE Allows for access of individual sensors. The number of entries is contained in the emsStatusSensorCount OID. | 1.3.6.1.4.1.318.1.1.10.3.18.1 | not-accessible | mandatory | |
| emsSensorStatusEntry OBJECT-TYPE The sensors to access. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1 | not-accessible | mandatory | |
| emsSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1.1 | INTEGER | read-only | mandatory |
| emsSensorStatusSensorSystemName OBJECT-TYPE The system name of the sensor. This describes the hardware system intent of this sensor. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1.2 | DisplayString | read-only | mandatory |
| emsSensorStatusSensorName OBJECT-TYPE The name of the sensor as given by the system user. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1.3 | DisplayString | read-only | mandatory |
| emsSensorStatusSensorState OBJECT-TYPE Getting this variable will return the sensor state. If the sensor is faulted, the sensorFaultedEMS (1) value will be returned. If the sensor is not faulted, the sensorOKEMS (2) value will be returned. If the sensor is not installed, the sensorNotInstalledEMS (3) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1.4 | INTEGER {sensorFaultedEMS(1), sensorOKEMS(2), sensorNotInstalledEMS(3)} | read-only | mandatory |
| emsSensorStatusSensorNormalState OBJECT-TYPE Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1.5 | INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)} | read-only | mandatory |
| emsSensorStatusSensorAlarmDelay OBJECT-TYPE The delay (in seconds) after a sensor detects an alarm condition before the condition is reported. | 1.3.6.1.4.1.318.1.1.10.3.18.1.1.6 | INTEGER | read-only | mandatory |
| emsInputStateSensorConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.19 | |||
| emsSmokeSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.19.1 | not-accessible | mandatory | |
| emsSmokeSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.3.19.1.1 | not-accessible | mandatory | |
| emsSmokeSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.19.1.1.1 | INTEGER | read-only | mandatory |
| emsSmokeSensorConfigSensorName OBJECT-TYPE The user defined name of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.1.1.2 | DisplayString | read-write | mandatory |
| emsSmokeSensorConfigSensorLocation OBJECT-TYPE The user defined location of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.1.1.3 | DisplayString | read-write | mandatory |
| emsSmokeSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.19.1.1.4 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| emsVibrationSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.19.2 | not-accessible | mandatory | |
| emsVibrationSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.3.19.2.1 | not-accessible | mandatory | |
| emsVibrationSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.19.2.1.1 | INTEGER | read-only | mandatory |
| emsVibrationSensorConfigSensorName OBJECT-TYPE The user defined name of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.2.1.2 | DisplayString | read-write | mandatory |
| emsVibrationSensorConfigSensorLocation OBJECT-TYPE The user defined location of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.2.1.3 | DisplayString | read-write | mandatory |
| emsVibrationSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.19.2.1.4 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| emsFluidSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.19.3 | not-accessible | mandatory | |
| emsFluidSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.3.19.3.1 | not-accessible | mandatory | |
| emsFluidSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.19.3.1.1 | INTEGER | read-only | mandatory |
| emsFluidSensorConfigSensorName OBJECT-TYPE The user defined name of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.3.1.2 | DisplayString | read-write | mandatory |
| emsFluidSensorConfigSensorLocation OBJECT-TYPE The user defined location of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.3.1.3 | DisplayString | read-write | mandatory |
| emsFluidSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.19.3.1.4 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| emsDoorSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.19.4 | not-accessible | mandatory | |
| emsDoorSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.3.19.4.1 | not-accessible | mandatory | |
| emsDoorSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.19.4.1.1 | INTEGER | read-only | mandatory |
| emsDoorSensorConfigSensorName OBJECT-TYPE The user defined name of the door sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.4.1.2 | DisplayString | read-write | mandatory |
| emsDoorSensorConfigSensorLocation OBJECT-TYPE The user defined location of the door sensor. | 1.3.6.1.4.1.318.1.1.10.3.19.4.1.3 | DisplayString | read-write | mandatory |
| emsDoorSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.19.4.1.4 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| emsInputStateSensorStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.3.20 | |||
| emsSmokeSensorStatusTableSize OBJECT-TYPE The number of entries in the emsSmokeSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.3.20.1 | INTEGER | read-only | mandatory |
| emsSmokeSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.20.2 | not-accessible | mandatory | |
| emsSmokeSensorStatusEntry OBJECT-TYPE The sensor to access. | 1.3.6.1.4.1.318.1.1.10.3.20.2.1 | not-accessible | mandatory | |
| emsSmokeSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.20.2.1.1 | INTEGER | read-only | mandatory |
| emsSmokeSensorStatusSensorName OBJECT-TYPE The user defined name of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.2.1.2 | DisplayString | read-only | mandatory |
| emsSmokeSensorStatusSensorLocation OBJECT-TYPE The user defined location of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.2.1.3 | DisplayString | read-only | mandatory |
| emsSmokeSensorStatusSensorState OBJECT-TYPE The state of the smoke sensor. smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.3.20.2.1.4 | INTEGER {smokeDetected(1), noSmoke(2), unknown(3)} | read-only | mandatory |
| emsSmokeSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.20.2.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| emsSmokeSensorCommStatus OBJECT-TYPE The communication status of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.2.1.6 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| emsVibrationSensorStatusTableSize OBJECT-TYPE The number of entries in the emsVibrationSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.3.20.3 | INTEGER | read-only | mandatory |
| emsVibrationSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.20.4 | not-accessible | mandatory | |
| emsVibrationSensorStatusEntry OBJECT-TYPE The sensor to access. | 1.3.6.1.4.1.318.1.1.10.3.20.4.1 | not-accessible | mandatory | |
| emsVibrationSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.20.4.1.1 | INTEGER | read-only | mandatory |
| emsVibrationSensorStatusSensorName OBJECT-TYPE The user defined name of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.4.1.2 | DisplayString | read-only | mandatory |
| emsVibrationSensorStatusSensorLocation OBJECT-TYPE The user defined location of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.4.1.3 | DisplayString | read-only | mandatory |
| emsVibrationSensorStatusSensorState OBJECT-TYPE The state of the vibration sensor. vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.3.20.4.1.4 | INTEGER {vibrationDetected(1), noVibration(2), unknown(3)} | read-only | mandatory |
| emsVibrationSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.20.4.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| emsVibrationSensorCommStatus OBJECT-TYPE The communication status of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.4.1.6 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| emsFluidSensorStatusTableSize OBJECT-TYPE The number of entries in the emsFluidSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.3.20.5 | INTEGER | read-only | mandatory |
| emsFluidSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.20.6 | not-accessible | mandatory | |
| emsFluidSensorStatusEntry OBJECT-TYPE The sensors to access. | 1.3.6.1.4.1.318.1.1.10.3.20.6.1 | not-accessible | mandatory | |
| emsFluidSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.20.6.1.1 | INTEGER | read-only | mandatory |
| emsFluidSensorStatusSensorName OBJECT-TYPE The user defined name of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.6.1.2 | DisplayString | read-only | mandatory |
| emsFluidSensorStatusSensorLocation OBJECT-TYPE The user defined location of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.6.1.3 | DisplayString | read-only | mandatory |
| emsFluidSensorStatusSensorState OBJECT-TYPE The state of the fluid sensor. fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.3.20.6.1.4 | INTEGER {fluidDetected(1), noFluid(2), unknown(3)} | read-only | mandatory |
| emsFluidSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.20.6.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| emsFluidSensorCommStatus OBJECT-TYPE The communication status of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.6.1.6 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| emsDoorSensorStatusTableSize OBJECT-TYPE The number of entries in the emsDoorSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.3.20.7 | INTEGER | read-only | mandatory |
| emsDoorSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.3.20.8 | not-accessible | mandatory | |
| emsDoorSensorStatusEntry OBJECT-TYPE The sensor to access. | 1.3.6.1.4.1.318.1.1.10.3.20.8.1 | not-accessible | mandatory | |
| emsDoorSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.3.20.8.1.1 | INTEGER | read-only | mandatory |
| emsDoorSensorStatusSensorName OBJECT-TYPE The user defined name of the door sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.8.1.2 | DisplayString | read-only | mandatory |
| emsDoorSensorStatusSensorLocation OBJECT-TYPE The user defined location of the door sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.8.1.3 | DisplayString | read-only | mandatory |
| emsDoorSensorStatusSensorState OBJECT-TYPE The state of the door sensor. open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.3.20.8.1.4 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| emsDoorSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.3.20.8.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| emsDoorSensorCommStatus OBJECT-TYPE The communication status of the door sensor. | 1.3.6.1.4.1.318.1.1.10.3.20.8.1.6 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| modEnvMgr OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4 | |||
| memModules OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.1 | |||
| memModulesStatusTableSize OBJECT-TYPE The number of entries in the memModulesStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.1.1 | INTEGER | read-only | mandatory |
| memModulesStatusTable OBJECT-TYPE Allows for getting status information from the modules attached to the system. | 1.3.6.1.4.1.318.1.1.10.4.1.2 | not-accessible | mandatory | |
| memModulesStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1 | not-accessible | mandatory | |
| memModulesStatusModuleNumber OBJECT-TYPE The module number. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.1 | INTEGER | read-only | mandatory |
| memModulesStatusModuleName OBJECT-TYPE The module name. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.2 | DisplayString | read-only | mandatory |
| memModulesStatusModuleLocation OBJECT-TYPE The location of the module. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.3 | DisplayString | read-only | mandatory |
| memModulesStatusModelNumber OBJECT-TYPE The model number of the module. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.4 | DisplayString | read-only | mandatory |
| memModulesStatusSerialNumber OBJECT-TYPE The serial number of the module. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.5 | DisplayString | read-only | mandatory |
| memModulesStatusFirmwareRev OBJECT-TYPE The firmware revision of the module. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.6 | DisplayString | read-only | mandatory |
| memModulesStatusHardwareRev OBJECT-TYPE The hardware revision. | 1.3.6.1.4.1.318.1.1.10.4.1.2.1.7 | DisplayString | read-only | mandatory |
| memModulesConfigTableSize OBJECT-TYPE The number of entries in the memModulesConfigTable. | 1.3.6.1.4.1.318.1.1.10.4.1.3 | INTEGER | read-only | mandatory |
| memModulesConfigTable OBJECT-TYPE Allows for getting status information from the modules attached to the system. | 1.3.6.1.4.1.318.1.1.10.4.1.4 | not-accessible | mandatory | |
| memModulesConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.1.4.1 | not-accessible | mandatory | |
| memModulesConfigModuleNumber OBJECT-TYPE The module number. | 1.3.6.1.4.1.318.1.1.10.4.1.4.1.1 | INTEGER | read-only | mandatory |
| memModulesConfigModuleName OBJECT-TYPE The module name. | 1.3.6.1.4.1.318.1.1.10.4.1.4.1.2 | DisplayString | read-write | mandatory |
| memModulesConfigModuleLocation OBJECT-TYPE The location of the module. | 1.3.6.1.4.1.318.1.1.10.4.1.4.1.3 | DisplayString | read-write | mandatory |
| memSensors OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.2 | |||
| memSensorsStatusSysTempUnits OBJECT-TYPE The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.10.4.2.1 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| memSensorsStatusTableSize OBJECT-TYPE The number of entries in the memSensorsStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.2.2 | INTEGER | read-only | mandatory |
| memSensorsStatusTable OBJECT-TYPE Allows for getting sensor status information. | 1.3.6.1.4.1.318.1.1.10.4.2.3 | not-accessible | mandatory | |
| memSensorsStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1 | not-accessible | mandatory | |
| memSensorsStatusModuleNumber OBJECT-TYPE The number of the module that the sensor is attached to. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.1 | INTEGER | read-only | mandatory |
| memSensorsStatusSensorNumber OBJECT-TYPE The number of this sensor on the module. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.2 | INTEGER | read-only | mandatory |
| memSensorsStatusSensorName OBJECT-TYPE The sensor name. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.3 | DisplayString | read-only | mandatory |
| memSensorsStatusSensorLocation OBJECT-TYPE The location of the sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.4 | DisplayString | read-only | mandatory |
| memSensorsTemperature OBJECT-TYPE The sensor's current temperature reading. Units are displayed in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.5 | INTEGER | read-only | mandatory |
| memSensorsHumidity OBJECT-TYPE The current humidity reading from the sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.6 | INTEGER | read-only | mandatory |
| memSensorsCommStatus OBJECT-TYPE The communications status of the sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.7 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| memSensorsAlarmStatus OBJECT-TYPE The alarm status of the sensor. memWarning is not applicable to voltage sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.8 | INTEGER {memNormal(1), memWarning(2), memCritical(3)} | read-only | mandatory |
| memSensorsTemperatureHighPrec OBJECT-TYPE The current temperature is displayed in tenths of degrees in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.9 | INTEGER | read-only | mandatory |
| memSensorsVoltage OBJECT-TYPE The sensor's current voltage reading. Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.4.2.3.1.10 | INTEGER | read-only | mandatory |
| memSensorsConfigTableSize OBJECT-TYPE The number of entries in the memSensorsConfigTable. | 1.3.6.1.4.1.318.1.1.10.4.2.4 | INTEGER | read-only | mandatory |
| memSensorsConfigTable OBJECT-TYPE Allows for getting configuration information from sensors attached to the system. | 1.3.6.1.4.1.318.1.1.10.4.2.5 | not-accessible | mandatory | |
| memSensorsConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1 | not-accessible | mandatory | |
| memSensorsConfigModuleNumber OBJECT-TYPE The number of the module that the sensor is attached to. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.1 | INTEGER | read-only | mandatory |
| memSensorsConfigSensorNumber OBJECT-TYPE The number of this sensor on the module. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.2 | INTEGER | read-only | mandatory |
| memSensorsName OBJECT-TYPE A descriptive name for the sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.3 | DisplayString | read-write | mandatory |
| memSensorsLocation OBJECT-TYPE The location of the sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.4 | DisplayString | read-write | mandatory |
| memSensorsAlarmGeneration OBJECT-TYPE Enable or disable alarm generation on this sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.5 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| memSensorsTempMaxThresh OBJECT-TYPE The temperature at which the MEM will generate a maximum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.6 | INTEGER | read-write | mandatory |
| memSensorsTempHighThresh OBJECT-TYPE The temperature at which the MEM will generate a high temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.7 | INTEGER | read-write | mandatory |
| memSensorsTempLowThresh OBJECT-TYPE The temperature at which the MEM will generate a low temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.8 | INTEGER | read-write | mandatory |
| memSensorsTempMinThresh OBJECT-TYPE The temperature at which the MEM will generate a minimum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.9 | INTEGER | read-write | mandatory |
| memSensorsTempThreshHysteresis OBJECT-TYPE The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.10 | INTEGER | read-write | mandatory |
| memSensorsTempShortDecRateThreshValue OBJECT-TYPE The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.11 | INTEGER | read-write | mandatory |
| memSensorsTempShortDecRateThreshTime OBJECT-TYPE The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.12 | INTEGER | read-write | mandatory |
| memSensorsTempShortIncRateThreshValue OBJECT-TYPE The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.13 | INTEGER | read-write | mandatory |
| memSensorsTempShortIncRateThreshTime OBJECT-TYPE The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.14 | INTEGER | read-write | mandatory |
| memSensorsTempLongDecRateThreshValue OBJECT-TYPE The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.15 | INTEGER | read-write | mandatory |
| memSensorsTempLongDecRateThreshTime OBJECT-TYPE The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.16 | INTEGER | read-write | mandatory |
| memSensorsTempLongIncRateThreshValue OBJECT-TYPE The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.17 | INTEGER | read-write | mandatory |
| memSensorsTempLongIncRateThreshTime OBJECT-TYPE The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.18 | INTEGER | read-write | mandatory |
| memSensorsHumidityMaxThresh OBJECT-TYPE The humidity at which the maximum humidity threshold alarm will be generated. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.19 | INTEGER | read-write | mandatory |
| memSensorsHumidityHighThresh OBJECT-TYPE The humidity at which the high humidity threshold alarm will be generated. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.20 | INTEGER | read-write | mandatory |
| memSensorsHumidityLowThresh OBJECT-TYPE The humidity at which the low humidity threshold alarm will be generated. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.21 | INTEGER | read-write | mandatory |
| memSensorsHumidityMinThresh OBJECT-TYPE The humidity at which the minimum humidity threshold alarm will be generated. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.22 | INTEGER | read-write | mandatory |
| memSensorsHumidityThreshHysteresis OBJECT-TYPE The change in humidity required to cause an active humidity alarm to change to the inactive state. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.23 | INTEGER | read-write | mandatory |
| memSensorsVoltMaxThresh OBJECT-TYPE The voltage at which the MEM will generate a maximum voltage threshold violation alarm on this sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.24 | INTEGER | read-write | mandatory |
| memSensorsVoltMinThresh OBJECT-TYPE The voltage at which the MEM will generate a minimum voltage threshold violation alarm on this sensor. | 1.3.6.1.4.1.318.1.1.10.4.2.5.1.25 | INTEGER | read-write | mandatory |
| memInputs OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.3 | |||
| memInputsStatusTableSize OBJECT-TYPE The number of entries in the memInputsStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.3.1 | INTEGER | read-only | mandatory |
| memInputsStatusTable OBJECT-TYPE Allows for getting input status information. | 1.3.6.1.4.1.318.1.1.10.4.3.2 | not-accessible | mandatory | |
| memInputsStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1 | not-accessible | mandatory | |
| memInputsStatusModuleNumber OBJECT-TYPE The number of the module that the input is attached to. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.1 | INTEGER | read-only | mandatory |
| memInputsStatusInputNumber OBJECT-TYPE The number of this input on the module. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.2 | INTEGER | read-only | mandatory |
| memInputsStatusInputName OBJECT-TYPE The input name. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.3 | DisplayString | read-only | mandatory |
| memInputsStatusInputLocation OBJECT-TYPE The location of the input. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.4 | DisplayString | read-only | mandatory |
| memInputsStatusCurrentState OBJECT-TYPE The current state of the input. This OID will return inputStateNotAplicable(4) for analog input types. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.5 | INTEGER {inputClosedHighMEM(1), inputOpenLowMEM(2), inputDisabled(3), inputStateNotApplicable(4)} | read-only | mandatory |
| memInputsStatusCurrentAnalogValue OBJECT-TYPE The current analog value of the input in the units defined by the user. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.6 | DisplayString | read-only | mandatory |
| memInputsStatusAlarmStatus OBJECT-TYPE The alarm status of the input. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.7 | INTEGER {memNormal(1), memWarning(2), memCritical(3)} | read-only | mandatory |
| memInputsCommStatus OBJECT-TYPE The communications status of the input. This OID is only supported by NBRK0200. | 1.3.6.1.4.1.318.1.1.10.4.3.2.1.8 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| memInputsConfigTableSize OBJECT-TYPE The number of entries in the memInputsConfigTable. | 1.3.6.1.4.1.318.1.1.10.4.3.3 | INTEGER | read-only | mandatory |
| memInputsConfigTable OBJECT-TYPE Allows for getting input configuration information. | 1.3.6.1.4.1.318.1.1.10.4.3.4 | not-accessible | mandatory | |
| memInputsConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1 | not-accessible | mandatory | |
| memInputsConfigModuleNumber OBJECT-TYPE The number of the module that the input is attached to. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.1 | INTEGER | read-only | mandatory |
| memInputsConfigInputNumber OBJECT-TYPE The number of this input on the module. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.2 | INTEGER | read-only | mandatory |
| memInputName OBJECT-TYPE The name of the input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.3 | DisplayString | read-write | mandatory |
| memInputLocation OBJECT-TYPE The location of the input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.4 | DisplayString | read-write | mandatory |
| memInputType OBJECT-TYPE The type of input this contact will take. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.5 | INTEGER {noConnection(1), dryContact(2), digital(3), analogmAmps(4), analogVolts(5)} | read-write | mandatory |
| memInputAlarmGeneration OBJECT-TYPE Enable or disable alarm generation on this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| memInputNormalState OBJECT-TYPE Defines the normal (no alarm) state of the input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.7 | INTEGER {inputClosedHighMEM(1), inputOpenLowMEM(2), inputDisabled(3), inputStateNotApplicable(4)} | read-write | mandatory |
| memInputAbnormalSeverity OBJECT-TYPE Defines the severity of the event that is associated with the abnormal state of the input. This OID will return inputSeverityNotApplicable(4) for analog input types. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.8 | INTEGER {inputSeverityinformational(1), inputSeveritywarning(2), inputSeveritysevere(3), inputSeverityNotApplicable(4)} | read-write | mandatory |
| memInputNumberCalibrationPoints OBJECT-TYPE The number of calibration points that are required for this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.9 | INTEGER | read-write | mandatory |
| memInputAnalogCalibrationPoint1 OBJECT-TYPE The electrical value that the input sensor will measure at the first calibration point. This OID is relevant only for inputs configured as analog type (ma or V). | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.10 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint2 OBJECT-TYPE The electrical value that the input sensor will measure at the second calibration point. This OID is relevant only for inputs configured as analog type (ma or V). | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.11 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint3 OBJECT-TYPE The electrical value that the input sensor will measure at the third calibration point. This OID is relevant only for inputs configured as analog type (ma or V). | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.12 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint4 OBJECT-TYPE The electrical value that the input sensor will measure at the fourth calibration point. This OID is relevant only for inputs configured as analog type (ma or V). | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.13 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint5 OBJECT-TYPE The electrical value that the input sensor will measure at the fifth calibration point. This OID is relevant only for inputs configured as analog type (ma or V). | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.14 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint1Value OBJECT-TYPE The value of the input, in units of measure defined by the user, that corresponds to the current setting at the first calibration point. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.15 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint2Value OBJECT-TYPE The value of the input, in units of measure defined by the user, that corresponds to the current setting at the second calibration point. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.16 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint3Value OBJECT-TYPE The value of the input, in units of measure defined by the user, that corresponds to the current setting at the third calibration point. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.17 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint4Value OBJECT-TYPE The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fourth calibration point. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.18 | DisplayString | read-write | mandatory |
| memInputAnalogCalibrationPoint5Value OBJECT-TYPE The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fifth calibration point. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.19 | DisplayString | read-write | mandatory |
| memInputAnalogMeasurementUnits OBJECT-TYPE The units of measure to be used for this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.20 | DisplayString | read-write | mandatory |
| memInputAnalogMaxThresh OBJECT-TYPE The input value at which a maximum threshold violation alarm will be generated on this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.21 | DisplayString | read-write | mandatory |
| memInputAnalogHighThresh OBJECT-TYPE The input value at which a high threshold violation alarm will be generated on this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.22 | DisplayString | read-write | mandatory |
| memInputAnalogLowThresh OBJECT-TYPE The input value at which a low threshold violation alarm will be generated on this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.23 | DisplayString | read-write | mandatory |
| memInputAnalogMinThresh OBJECT-TYPE The input value at which a minimum threshold violation alarm will be generated on this input. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.24 | DisplayString | read-write | mandatory |
| memInputAnalogThreshHysteresis OBJECT-TYPE The change in value required to cause an alarm on this input to change from active to inactive. | 1.3.6.1.4.1.318.1.1.10.4.3.4.1.25 | DisplayString | read-write | mandatory |
| memOutputs OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.4 | |||
| memOutputStatusTableSize OBJECT-TYPE The number of entries in the memOutputStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.4.1 | INTEGER | read-only | mandatory |
| memOutputStatusTable OBJECT-TYPE Allows for getting output status information. | 1.3.6.1.4.1.318.1.1.10.4.4.2 | not-accessible | mandatory | |
| memOutputStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1 | not-accessible | mandatory | |
| memOutputStatusModuleNumber OBJECT-TYPE The number of the module that the output is attached to. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1.1 | INTEGER | read-only | mandatory |
| memOutputStatusOutputNumber OBJECT-TYPE The number of this output on the module. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1.2 | INTEGER | read-only | mandatory |
| memOutputStatusOutputName OBJECT-TYPE The output name. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1.3 | DisplayString | read-only | mandatory |
| memOutputStatusOutputLocation OBJECT-TYPE The location of the output. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1.4 | DisplayString | read-only | mandatory |
| memOutputStatusCurrentState OBJECT-TYPE The state of the output. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1.5 | INTEGER {memOutputClosed(1), memOutputOpen(2)} | read-only | mandatory |
| memOutputStatusAlarmState OBJECT-TYPE The alarm state of the output. | 1.3.6.1.4.1.318.1.1.10.4.4.2.1.6 | INTEGER {memOutputNormal(1), memOutputAbnormal(2)} | read-only | mandatory |
| memOutputConfigTableSize OBJECT-TYPE The number of entries in the memOutputConfigTable. | 1.3.6.1.4.1.318.1.1.10.4.4.3 | INTEGER | read-only | mandatory |
| memOutputConfigTable OBJECT-TYPE Allows for getting output configuration information. | 1.3.6.1.4.1.318.1.1.10.4.4.4 | not-accessible | mandatory | |
| memOutputConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1 | not-accessible | mandatory | |
| memOutputConfigModuleNumber OBJECT-TYPE The number of the module that the output is attached to. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1.1 | INTEGER | read-only | mandatory |
| memOutputConfigOutputNumber OBJECT-TYPE The number of this output on the module. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1.2 | INTEGER | read-only | mandatory |
| memOutputName OBJECT-TYPE The name of the output. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1.3 | DisplayString | read-write | mandatory |
| memOutputLocation OBJECT-TYPE The location of the output. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1.4 | DisplayString | read-write | mandatory |
| memOutputNormalState OBJECT-TYPE The state of the output that will not generate an alarm. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1.5 | INTEGER {memOutputClosed(1), memOutputOpen(2)} | read-write | mandatory |
| memOutputAction OBJECT-TYPE Manual control actions for the output. SNMP get command will return the state of the output, SNMP set of this OID controls the output. | 1.3.6.1.4.1.318.1.1.10.4.4.4.1.6 | INTEGER {memActionClose(1), memActionOpen(2)} | read-write | mandatory |
| memOutlets OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.5 | |||
| memOutletStatusTableSize OBJECT-TYPE The number of entries in the memOutletStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.5.1 | INTEGER | read-only | mandatory |
| memOutletStatusTable OBJECT-TYPE Allows for getting outlet status information. | 1.3.6.1.4.1.318.1.1.10.4.5.2 | not-accessible | mandatory | |
| memOutletStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1 | not-accessible | mandatory | |
| memOutletStatusModuleNumber OBJECT-TYPE The number of the module that the outlet is attached to. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1.1 | INTEGER | read-only | mandatory |
| memOutletStatusOutletNumber OBJECT-TYPE The number of this outlet on the module. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1.2 | INTEGER | read-only | mandatory |
| memOutletStatusOutletName OBJECT-TYPE The outlet name. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1.3 | DisplayString | read-only | mandatory |
| memOutletStatusOutletLocation OBJECT-TYPE The location of the outlet. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1.4 | DisplayString | read-only | mandatory |
| memOutletStatusCurrentState OBJECT-TYPE The state of the outlet. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1.5 | INTEGER {off(1), on(2)} | read-only | mandatory |
| memOutletStatusAlarmState OBJECT-TYPE The alarm state of the outlet. | 1.3.6.1.4.1.318.1.1.10.4.5.2.1.6 | INTEGER {memOutletNormal(1), memOutletAbnormal(2)} | read-only | mandatory |
| memOutletConfigTableSize OBJECT-TYPE The number of entries in the memOutletConfigTable. | 1.3.6.1.4.1.318.1.1.10.4.5.3 | INTEGER | read-only | mandatory |
| memOutletConfigTable OBJECT-TYPE Allows for getting outlet configuration information. | 1.3.6.1.4.1.318.1.1.10.4.5.4 | not-accessible | mandatory | |
| memOutletConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1 | not-accessible | mandatory | |
| memOutletConfigModuleNumber OBJECT-TYPE The number of the module that the Outlet is attached to. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1.1 | INTEGER | read-only | mandatory |
| memOutletConfigOutletNumber OBJECT-TYPE The number of this Outlet on the module. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1.2 | INTEGER | read-only | mandatory |
| memOutletName OBJECT-TYPE The name of the Outlet. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1.3 | DisplayString | read-write | mandatory |
| memOutletLocation OBJECT-TYPE The location of the Outlet. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1.4 | DisplayString | read-write | mandatory |
| memOutletNormalState OBJECT-TYPE The state of the Outlet that will not generate an alarm. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1.5 | INTEGER {off(1), on(2)} | read-write | mandatory |
| memOutletAction OBJECT-TYPE Manual control actions for the Outlet. Get displays state of outlet, set controls outlet. | 1.3.6.1.4.1.318.1.1.10.4.5.4.1.6 | INTEGER {turnOff(1), turnOn(2)} | read-write | mandatory |
| memBeacons OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.6 | |||
| memBeaconStatusTableSize OBJECT-TYPE The number of entries in the memBeaconStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.6.1 | INTEGER | read-only | mandatory |
| memBeaconStatusTable OBJECT-TYPE Allows for getting beacon status information. | 1.3.6.1.4.1.318.1.1.10.4.6.2 | not-accessible | mandatory | |
| memBeaconStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1 | not-accessible | mandatory | |
| memBeaconStatusModuleNumber OBJECT-TYPE The number of the module that the beacon is attached to. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1.1 | INTEGER | read-only | mandatory |
| memBeaconStatusBeaconNumber OBJECT-TYPE The number of this beacon on the module. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1.2 | INTEGER | read-only | mandatory |
| memBeaconStatusBeaconName OBJECT-TYPE The beacon name. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1.3 | DisplayString | read-only | mandatory |
| memBeaconStatusBeaconLocation OBJECT-TYPE The location of the beacon. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1.4 | DisplayString | read-only | mandatory |
| memBeaconStatusCurrentState OBJECT-TYPE The state of the beacon. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1.5 | INTEGER {off(1), on(2)} | read-only | mandatory |
| memBeaconStatusAlarmState OBJECT-TYPE The alarm state of the beacon. | 1.3.6.1.4.1.318.1.1.10.4.6.2.1.6 | INTEGER {memBeaconNormal(1), memBeaconAbnormal(2)} | read-only | mandatory |
| memBeaconConfigTableSize OBJECT-TYPE The number of entries in the memBeaconConfigTable. | 1.3.6.1.4.1.318.1.1.10.4.6.3 | INTEGER | read-only | mandatory |
| memBeaconConfigTable OBJECT-TYPE Allows for getting beacon configuration information. | 1.3.6.1.4.1.318.1.1.10.4.6.4 | not-accessible | mandatory | |
| memBeaconConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.10.4.6.4.1 | not-accessible | mandatory | |
| memBeaconConfigModuleNumber OBJECT-TYPE The number of the module that the beacon is attached to. | 1.3.6.1.4.1.318.1.1.10.4.6.4.1.1 | INTEGER | read-only | mandatory |
| memBeaconConfigBeaconNumber OBJECT-TYPE The number of this beacon on the module. | 1.3.6.1.4.1.318.1.1.10.4.6.4.1.2 | INTEGER | read-only | mandatory |
| memBeaconConfigName OBJECT-TYPE The name of the beacon. | 1.3.6.1.4.1.318.1.1.10.4.6.4.1.3 | DisplayString | read-write | mandatory |
| memBeaconConfigLocation OBJECT-TYPE The location of the beacon. | 1.3.6.1.4.1.318.1.1.10.4.6.4.1.4 | DisplayString | read-write | mandatory |
| memBeaconAction OBJECT-TYPE Control action (on/off) for the beacon. Setting this OID will turn the beacon on/off. Getting this OID will respond with the current state. | 1.3.6.1.4.1.318.1.1.10.4.6.4.1.5 | INTEGER {turnOff(1), turnOn(2)} | read-write | mandatory |
| memInputStateSensors OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.4.7 | |||
| memSmokeSensorStatusTableSize OBJECT-TYPE The number of entries in the memSmokeSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.7.1 | INTEGER | read-only | mandatory |
| memSmokeSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.2 | not-accessible | mandatory | |
| memSmokeSensorStatusEntry OBJECT-TYPE The sensor to access. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1 | not-accessible | mandatory | |
| memSmokeSensorStatusModuleIndex OBJECT-TYPE The index to the module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.1 | INTEGER | read-only | mandatory |
| memSmokeSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.2 | INTEGER | read-only | mandatory |
| memSmokeSensorStatusSensorName OBJECT-TYPE The user defined name of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.3 | DisplayString | read-only | mandatory |
| memSmokeSensorStatusSensorLocation OBJECT-TYPE The user defined location of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.4 | DisplayString | read-only | mandatory |
| memSmokeSensorStatusSensorState OBJECT-TYPE The state of the smoke sensor. smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.5 | INTEGER {smokeDetected(1), noSmoke(2), unknown(3)} | read-only | mandatory |
| memSmokeSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.6 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| memSmokeStatusAlarmStatus OBJECT-TYPE The alarm status of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.7 | INTEGER {memNormal(1), memWarning(2), memCritical(3)} | read-only | mandatory |
| memSmokeSensorCommStatus OBJECT-TYPE The communication status of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.2.1.8 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| memVibrationSensorStatusTableSize OBJECT-TYPE The number of entries in the memVibrationSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.7.3 | INTEGER | read-only | mandatory |
| memVibrationSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.4 | not-accessible | mandatory | |
| memVibrationSensorStatusEntry OBJECT-TYPE The sensors to access. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1 | not-accessible | mandatory | |
| memVibrationSensorStatusModuleIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.1 | INTEGER | read-only | mandatory |
| memVibrationSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.2 | INTEGER | read-only | mandatory |
| memVibrationSensorStatusSensorName OBJECT-TYPE The user defined name of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.3 | DisplayString | read-only | mandatory |
| memVibrationSensorStatusSensorLocation OBJECT-TYPE The user defined location of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.4 | DisplayString | read-only | mandatory |
| memVibrationSensorStatusSensorState OBJECT-TYPE The state of the vibration sensor. vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.5 | INTEGER {vibrationDetected(1), noVibration(2), unknown(3)} | read-only | mandatory |
| memVibrationSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.6 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| memVibrationStatusAlarmStatus OBJECT-TYPE The alarm status of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.7 | INTEGER {memNormal(1), memWarning(2), memCritical(3)} | read-only | mandatory |
| memVibrationSensorCommStatus OBJECT-TYPE The communication status of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.4.1.8 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| memFluidSensorStatusTableSize OBJECT-TYPE The number of entries in the memFluidSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.7.5 | INTEGER | read-only | mandatory |
| memFluidSensorStatusTable OBJECT-TYPE Allows for access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.6 | not-accessible | mandatory | |
| memFluidSensorStatusEntry OBJECT-TYPE The sensor to access. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1 | not-accessible | mandatory | |
| memFluidSensorStatusModuleIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.1 | INTEGER | read-only | mandatory |
| memFluidSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.2 | INTEGER | read-only | mandatory |
| memFluidSensorStatusSensorName OBJECT-TYPE The user defined name of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.3 | DisplayString | read-only | mandatory |
| memFluidSensorStatusSensorLocation OBJECT-TYPE The user defined location of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.4 | DisplayString | read-only | mandatory |
| memFluidSensorStatusSensorState OBJECT-TYPE The state of the fluid sensor. fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.5 | INTEGER {fluidDetected(1), noFluid(2), unknown(3)} | read-only | mandatory |
| memFluidSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.6 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| memFluidStatusAlarmStatus OBJECT-TYPE The alarm status of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.7 | INTEGER {memNormal(1), memWarning(2), memCritical(3)} | read-only | mandatory |
| memFluidSensorCommStatus OBJECT-TYPE The communication status of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.6.1.8 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| memDoorSensorStatusTableSize OBJECT-TYPE The number of entries in the memDoorSensorStatusTable. | 1.3.6.1.4.1.318.1.1.10.4.7.7 | INTEGER | read-only | mandatory |
| memDoorSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.8 | not-accessible | mandatory | |
| memDoorSensorStatusEntry OBJECT-TYPE The sensor to access. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1 | not-accessible | mandatory | |
| memDoorSensorStatusModuleIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.1 | INTEGER | read-only | mandatory |
| memDoorSensorStatusSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.2 | INTEGER | read-only | mandatory |
| memDoorSensorStatusSensorName OBJECT-TYPE The user defined name of the door sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.3 | DisplayString | read-only | mandatory |
| memDoorSensorStatusSensorLocation OBJECT-TYPE The user defined location of the door sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.4 | DisplayString | read-only | mandatory |
| memDoorSensorStatusSensorState OBJECT-TYPE The state of the door sensor. open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.5 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| memDoorSensorStatusSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.6 | INTEGER {critical(1), warning(2), informational(3)} | read-only | mandatory |
| memDoorStatusAlarmStatus OBJECT-TYPE The alarm status of the door sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.7 | INTEGER {memNormal(1), memWarning(2), memCritical(3)} | read-only | mandatory |
| memDoorSensorCommStatus OBJECT-TYPE The communication status of the door sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.8.1.8 | INTEGER {commOK(1), commLost(2)} | read-only | mandatory |
| memSmokeSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.9 | not-accessible | mandatory | |
| memSmokeSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.4.7.9.1 | not-accessible | mandatory | |
| memSmokeSensorConfigSensorModuleIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.9.1.1 | INTEGER | read-only | mandatory |
| memSmokeSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.9.1.2 | INTEGER | read-only | mandatory |
| memSmokeSensorConfigSensorName OBJECT-TYPE The user defined name of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.9.1.3 | DisplayString | read-write | mandatory |
| memSmokeSensorConfigSensorLocation OBJECT-TYPE The user defined location of the smoke sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.9.1.4 | DisplayString | read-write | mandatory |
| memSmokeSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.9.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| memSmokeSensorConfigAlarmGeneration OBJECT-TYPE Enable or disable alarm generation on this input. | 1.3.6.1.4.1.318.1.1.10.4.7.9.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| memVibrationSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.10 | not-accessible | mandatory | |
| memVibrationSensorConfigEntry OBJECT-TYPE The sensor to configure. | 1.3.6.1.4.1.318.1.1.10.4.7.10.1 | not-accessible | mandatory | |
| memVibrationSensorModuleConfigIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.10.1.1 | INTEGER | read-only | mandatory |
| memVibrationSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.10.1.2 | INTEGER | read-only | mandatory |
| memVibrationSensorConfigSensorName OBJECT-TYPE The user defined name of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.10.1.3 | DisplayString | read-write | mandatory |
| memVibrationSensorConfigSensorLocation OBJECT-TYPE The user defined location of the vibration sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.10.1.4 | DisplayString | read-write | mandatory |
| memVibrationSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.10.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| memVibrationSensorConfigAlarmGeneration OBJECT-TYPE Enable or disable alarm generation on this input. | 1.3.6.1.4.1.318.1.1.10.4.7.10.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| memFluidSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.11 | not-accessible | mandatory | |
| memFluidSensorConfigEntry OBJECT-TYPE The sensor to configure. | 1.3.6.1.4.1.318.1.1.10.4.7.11.1 | not-accessible | mandatory | |
| memFluidSensorModuleConfigIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.11.1.1 | INTEGER | read-only | mandatory |
| memFluidSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.11.1.2 | INTEGER | read-only | mandatory |
| memFluidSensorConfigSensorName OBJECT-TYPE The user defined name of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.11.1.3 | DisplayString | read-write | mandatory |
| memFluidSensorConfigSensorLocation OBJECT-TYPE The user defined location of the fluid sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.11.1.4 | DisplayString | read-write | mandatory |
| memFluidSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.11.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| memFluidSensorConfigAlarmGeneration OBJECT-TYPE Enable or disable alarm generation on this input. | 1.3.6.1.4.1.318.1.1.10.4.7.11.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| memDoorSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.4.7.12 | not-accessible | mandatory | |
| memDoorSensorConfigEntry OBJECT-TYPE The sensors to configure. | 1.3.6.1.4.1.318.1.1.10.4.7.12.1 | not-accessible | mandatory | |
| memDoorSensorModuleConfigIndex OBJECT-TYPE The index to the sensor module entry. | 1.3.6.1.4.1.318.1.1.10.4.7.12.1.1 | INTEGER | read-only | mandatory |
| memDoorSensorConfigSensorIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.4.7.12.1.2 | INTEGER | read-only | mandatory |
| memDoorSensorConfigSensorName OBJECT-TYPE The user defined name of the door sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.12.1.3 | DisplayString | read-write | mandatory |
| memDoorSensorConfigSensorLocation OBJECT-TYPE The user defined location of the door sensor. | 1.3.6.1.4.1.318.1.1.10.4.7.12.1.4 | DisplayString | read-write | mandatory |
| memDoorSensorConfigSensorSeverity OBJECT-TYPE The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). | 1.3.6.1.4.1.318.1.1.10.4.7.12.1.5 | INTEGER {critical(1), warning(2), informational(3)} | read-write | mandatory |
| memDoorSensorConfigAlarmGeneration OBJECT-TYPE Enable or disable alarm generation on this input. | 1.3.6.1.4.1.318.1.1.10.4.7.12.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| envWireless OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.5 | |||
| wirelessSensorStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.5.1 | |||
| wirelessSensorStatusTable OBJECT-TYPE Allows for the access of individual sensors. | 1.3.6.1.4.1.318.1.1.10.5.1.1 | not-accessible | mandatory | |
| wirelessSensorStatusEntry OBJECT-TYPE A list of wireless sensor status table entries. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1 | not-accessible | mandatory | |
| wirelessSensorStatusIndex OBJECT-TYPE The index to the sensor entry. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.1 | INTEGER | read-only | mandatory |
| wirelessSensorStatusExtAddr OBJECT-TYPE The extended address is the combination of the unique 10 byte MAC address of the sensor concatenated with its short address. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.2 | DisplayString | read-only | mandatory |
| wirelessSensorStatusName OBJECT-TYPE The name of the wireless sensor. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.3 | DisplayString | read-only | mandatory |
| wirelessSensorStatusAlarmGeneration OBJECT-TYPE Indicates whether alarm generation is enabled or disabled for the sensor. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.4 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| wirelessSensorStatusTemperature OBJECT-TYPE The current temperature are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.5 | INTEGER | read-only | mandatory |
| wirelessSensorStatusHighTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.6 | INTEGER | read-only | mandatory |
| wirelessSensorStatusLowTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.7 | INTEGER | read-only | mandatory |
| wirelessSensorStatusHumidity OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.8 | INTEGER | read-only | mandatory |
| wirelessSensorStatusHighHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.9 | INTEGER | read-only | mandatory |
| wirelessSensorStatusLowHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.10 | INTEGER | read-only | mandatory |
| wirelessSensorStatusCommStatus OBJECT-TYPE The communication status of the wireless sensor. inactive(0) indicates sensor is in the wireless network but not sending information. active(1) indicates wireless sensor is live and sending information. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.11 | INTEGER {inactive(0), active(1)} | read-only | mandatory |
| wirelessSensorStatusMaxTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.12 | INTEGER | read-only | mandatory |
| wirelessSensorStatusMinTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.13 | INTEGER | read-only | mandatory |
| wirelessSensorStatusMaxHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.14 | INTEGER | read-only | mandatory |
| wirelessSensorStatusMinHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.15 | INTEGER | read-only | mandatory |
| wirelessSensorStatusBattery OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.16 | INTEGER | read-only | mandatory |
| wirelessSensorStatusLowBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.17 | INTEGER | read-only | mandatory |
| wirelessSensorStatusMinBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.18 | INTEGER | read-only | mandatory |
| wirelessSensorStatusRssi OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.19 | INTEGER | read-only | mandatory |
| wirelessSensorStatusLowRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.20 | INTEGER | read-only | mandatory |
| wirelessSensorStatusMinRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.21 | INTEGER | read-only | mandatory |
| wirelessSensorStatusLocation OBJECT-TYPE A user-defined string identifying the location of the wireless sensor. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.22 | DisplayString | read-only | mandatory |
| wirelessSensorStatusAlarmStatus OBJECT-TYPE The alarm status of the wireless sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Maximum humidity exceeded. 6 0x0020 High humidity exceeded. 7 0x0040 Low humidity exceeded. 8 0x0080 Minimum humidity exceeded. 9 0x0100 Low battery exceeded. 10 0x0200 Minimum battery exceeded. 11 0x0400 Low signal strength exceeded. 12 0x0800 Minimum signal strength exceeded. 13 0x1000 Sensor inactive. | 1.3.6.1.4.1.318.1.1.10.5.1.1.1.23 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.5.2 | |||
| wirelessSensorPodStatusTable OBJECT-TYPE Allows for the access of individual pod sensors. | 1.3.6.1.4.1.318.1.1.10.5.2.1 | not-accessible | mandatory | |
| wirelessSensorPodStatusEntry OBJECT-TYPE The sensor pod to access. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1 | not-accessible | mandatory | |
| wirelessSensorPodStatusIndex OBJECT-TYPE The index to the pod sensor entry. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.1 | INTEGER | read-only | mandatory |
| wirelessSensorPodPortIndex OBJECT-TYPE The pod sensor port index. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.2 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusExtAddr OBJECT-TYPE The extended address is the combination of the unique 10 byte MAC address of the sensor concatenated with its short address. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.3 | DisplayString | read-only | mandatory |
| wirelessSensorPodStatusName OBJECT-TYPE The name of the sensor pod. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.4 | DisplayString | read-only | mandatory |
| wirelessSensorPodStatusAlarmGeneration OBJECT-TYPE Status of whether alarm generation is enabled or disabled. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.5 | INTEGER {disabled(0), enabled(1)} | read-only | mandatory |
| wirelessSensorPodStatusTemperature OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.6 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusHighTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.7 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusLowTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.8 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusHumidity OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.9 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusHighHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.10 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusLowHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.11 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusCommStatus OBJECT-TYPE The communication status of the wireless sensor. inactive(0) indicates pod sensor is in the wireless network but not sending information. active(1) indicates wireless sensor is live and sending information. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.12 | INTEGER {inactive(0), active(1)} | read-only | mandatory |
| wirelessSensorPodStatusMaxTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.13 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusMinTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.14 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusMaxHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.15 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusMinHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.16 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusDryContactState OBJECT-TYPE State of the dry contact. If the dry contact is closed, the drycontactClosed (1) value will be returned. If the dry contact state is open, the drycontactOpen (0) value will be returned. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.17 | INTEGER {drycontactOpen(0), drycontactClosed(1)} | read-only | mandatory |
| wirelessSensorPodStatusDryContactNormalState OBJECT-TYPE The normal state of the dry contact. If the normal state is closed, the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpen (0) value will be returned. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.18 | INTEGER {normallyOpen(0), normallyClosed(1)} | read-only | mandatory |
| wirelessSensorPodStatusBattery OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.19 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusLowBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.20 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusMinBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.21 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusRssi OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.22 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusLowRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.23 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusMinRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.24 | INTEGER | read-only | mandatory |
| wirelessSensorPodStatusLocation OBJECT-TYPE The location of the wireless sensor pod. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.25 | DisplayString | read-only | mandatory |
| wirelessSensorPodStatusAlarmStatus OBJECT-TYPE The alarm status of the wireless pod sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Maximum humidity exceeded. 6 0x0020 High humidity exceeded. 7 0x0040 Low humidity exceeded. 8 0x0080 Minimum humidity exceeded. 9 0x0100 Low battery exceeded. 10 0x0200 Minimum battery exceeded. 11 0x0400 Low signal strength exceeded. 12 0x0800 Minimum signal strength exceeded. 13 0x1000 Sensor inactive. 14 0x2000 Dry contact in Critical state. 15 0x4000 Dry contact in warning state. | 1.3.6.1.4.1.318.1.1.10.5.2.1.1.26 | INTEGER | read-only | mandatory |
| wirelessSensorConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.5.3 | |||
| wirelessSensorConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.5.3.1 | not-accessible | mandatory | |
| wirelessSensorConfigEntry OBJECT-TYPE The sensor to configure. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1 | not-accessible | mandatory | |
| wirelessSensorConfigIndex OBJECT-TYPE The index to the entry. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.1 | INTEGER | read-only | mandatory |
| wirelessSensorConfigName OBJECT-TYPE The user-defined wireless sensor ID string. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.2 | DisplayString | read-write | mandatory |
| wirelessSensorConfigAlarmGeneration OBJECT-TYPE Enable or disable alarm generation for this sensor. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.3 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| wirelessSensorConfigHighTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.4 | INTEGER | read-write | mandatory |
| wirelessSensorConfigLowTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.5 | INTEGER | read-write | mandatory |
| wirelessSensorConfigHighHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.6 | INTEGER | read-write | mandatory |
| wirelessSensorConfigLowHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.7 | INTEGER | read-write | mandatory |
| wirelessSensorConfigMaxTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.8 | INTEGER | read-write | mandatory |
| wirelessSensorConfigMinTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.9 | INTEGER | read-write | mandatory |
| wirelessSensorConfigMaxHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.10 | INTEGER | read-write | mandatory |
| wirelessSensorConfigMinHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.11 | INTEGER | read-write | mandatory |
| wirelessSensorConfigLowBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.12 | INTEGER | read-write | mandatory |
| wirelessSensorConfigMinBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.13 | INTEGER | read-write | mandatory |
| wirelessSensorConfigLowRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.14 | INTEGER | read-write | mandatory |
| wirelessSensorConfigMinRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.15 | INTEGER | read-write | mandatory |
| wirelessSensorConfigLocation OBJECT-TYPE A user-defined string identifying the location of the wireless sensor. Maximum text input is 20 characters. | 1.3.6.1.4.1.318.1.1.10.5.3.1.1.16 | DisplayString | read-write | mandatory |
| wirelessSensorPodConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.10.5.4 | |||
| wirelessSensorPodConfigTable OBJECT-TYPE Allows for the configuration of individual sensors. | 1.3.6.1.4.1.318.1.1.10.5.4.1 | not-accessible | mandatory | |
| wirelessSensorPodConfigEntry OBJECT-TYPE The sensor to configure. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1 | not-accessible | mandatory | |
| wirelessSensorPodConfigIndex OBJECT-TYPE The index to the entry. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.1 | INTEGER | read-only | mandatory |
| wirelessSensorPodConfigPortIndex OBJECT-TYPE The sensor pod port index. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.2 | INTEGER | read-only | mandatory |
| wirelessSensorPodConfigName OBJECT-TYPE The user defined name of the sensor pod. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.3 | DisplayString | read-write | mandatory |
| wirelessSensorPodConfigAlarmGeneration OBJECT-TYPE Enable or disable alarm generation for this sensor. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.4 | INTEGER {disabled(0), enabled(1)} | read-write | mandatory |
| wirelessSensorPodConfigDryContactNormalState OBJECT-TYPE The normal state of the dry contact. If the normal state is closed, the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpen (0) value will be returned. Setting this variable will change the normal state of the dry contact. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.5 | INTEGER {normallyOpen(0), normallyClosed(1)} | read-write | mandatory |
| wirelessSensorPodConfigHighTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.6 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigLowTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.7 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigHighHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.8 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigLowHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.9 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigMaxTempThresh OBJECT-TYPE Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.10 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigMinTempThresh OBJECT-TYPE Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.11 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigMaxHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.12 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigMinHumidityThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.13 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigLowBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.14 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigMinBatteryThresh OBJECT-TYPE Values are displayed in tenths of Volts DC. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.15 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigLowRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.16 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigMinRssiThresh OBJECT-TYPE Values are represented in whole number percentage. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.17 | INTEGER | read-write | mandatory |
| wirelessSensorPodConfigLocation OBJECT-TYPE A user-defined string identifying the location of the wireless pod sensor. Maximum text input is 20 characters. | 1.3.6.1.4.1.318.1.1.10.5.4.1.1.18 | DisplayString | read-write | mandatory |
| netlock OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.11 | |||
| nlIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.11.1 | |||
| nlStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.11.2 | |||
| rPDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12 | |||
| rPDUIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.1 | |||
| rPDUIdentName OBJECT-TYPE The name of the Rack PDU. The maximum string size is device dependent. | 1.3.6.1.4.1.318.1.1.12.1.1 | DisplayString | read-write | mandatory |
| rPDUIdentHardwareRev OBJECT-TYPE The hardware revision of the Rack PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.12.1.2 | DisplayString | read-only | mandatory |
| rPDUIdentFirmwareRev OBJECT-TYPE An 8-byte ID string identifying the Rack PDU firmware revision. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.12.1.3 | DisplayString | read-only | mandatory |
| rPDUIdentDateOfManufacture OBJECT-TYPE The date when the Rack PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. The year 2000 will be represented by 00. | 1.3.6.1.4.1.318.1.1.12.1.4 | DisplayString | read-only | mandatory |
| rPDUIdentModelNumber OBJECT-TYPE A 10-character string identifying the model number of the Rack PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.12.1.5 | DisplayString | read-only | mandatory |
| rPDUIdentSerialNumber OBJECT-TYPE A 12-character string identifying the serial number of the Rack PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.12.1.6 | DisplayString | read-only | mandatory |
| rPDUIdentDeviceRating OBJECT-TYPE Getting this OID will return the electrical rating of the device in Amps. | 1.3.6.1.4.1.318.1.1.12.1.7 | INTEGER | read-only | mandatory |
| rPDUIdentDeviceNumOutlets OBJECT-TYPE Getting this OID will return the number of outlets contained in the device. | 1.3.6.1.4.1.318.1.1.12.1.8 | INTEGER | read-only | mandatory |
| rPDUIdentDeviceNumPhases OBJECT-TYPE Getting this OID will return the number of phases supported by the device. | 1.3.6.1.4.1.318.1.1.12.1.9 | INTEGER | read-only | mandatory |
| rPDUIdentDeviceNumBreakers OBJECT-TYPE Getting this OID will return the number of circuit breakers supported by the device. This is the same as the number of banks of outlets. 0 will be returned if the unit has no phase breakers. | 1.3.6.1.4.1.318.1.1.12.1.10 | INTEGER | read-only | mandatory |
| rPDUIdentDeviceBreakerRating OBJECT-TYPE Getting this OID will return rating of the circuit breakers on the device in Amps if it has any. | 1.3.6.1.4.1.318.1.1.12.1.11 | INTEGER | read-only | mandatory |
| rPDUIdentDeviceOrientation OBJECT-TYPE Getting this OID will return the intended physical orientation of the device. OrientHorizonatal(1) indicates Horizontal. OrientVertical(2) indicates Vertical. | 1.3.6.1.4.1.318.1.1.12.1.12 | INTEGER {orientHorizontal(1), orientVertical(2)} | read-only | mandatory |
| rPDUIdentDeviceOutletLayout OBJECT-TYPE Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. For AP7xxx SKU's Group 1:3-1. Group 2:2-3, Group 3:1-2. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available. | 1.3.6.1.4.1.318.1.1.12.1.13 | INTEGER {seqPhaseToNeutral(1), seqPhaseToPhase(2), seqPhToNeu21PhToPh(3), seqPhToPhGrouped(4), seqPhToNGrouped(5), seqPToN1516PToPGrouped(6), seqPhToPh2xGrouped(7), seqPhToN2xGrouped(8), seqNotApplicable(9)} | read-only | mandatory |
| rPDUIdentDeviceDisplayOrientation OBJECT-TYPE Getting this OID will return the intended physical orientation of the Seven-Segment Display. Normal(1) indicates Normal. Reverse(2)indicates Upside-Down. | 1.3.6.1.4.1.318.1.1.12.1.14 | INTEGER {displayNormal(1), displayReverse(2)} | read-write | mandatory |
| rPDUIdentDeviceLinetoLineVoltage OBJECT-TYPE Getting/Setting this OID will return/set the Line to Line Voltage. This OID defaults to the nominal input line voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. The valid range is between 0V to 440V | 1.3.6.1.4.1.318.1.1.12.1.15 | INTEGER | read-write | mandatory |
| rPDUIdentDevicePowerWatts OBJECT-TYPE Getting this OID will return the Power in Watts. | 1.3.6.1.4.1.318.1.1.12.1.16 | INTEGER | read-only | mandatory |
| rPDUIdentDevicePowerFactor OBJECT-TYPE Getting/setting this OID will return/set the Power Factor in thousandths (1000 is power factor of 1). For AP8XXX SKUs, this OID is read-only Valid range is from 0 to 1000. | 1.3.6.1.4.1.318.1.1.12.1.17 | INTEGER | read-write | mandatory |
| rPDUIdentDevicePowerVA OBJECT-TYPE Getting this OID will return the Power in VA. | 1.3.6.1.4.1.318.1.1.12.1.18 | INTEGER | read-only | mandatory |
| rPDUIdentDeviceLinetoNeutralVoltage OBJECT-TYPE Getting/Setting this OID will return/set the Line to Neutral Voltage. This OID defaults to the nominal line to neutral voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID applies only to AP7823. For all other models, the OID is fixed at 0. The valid range is between 0V to 440V. | 1.3.6.1.4.1.318.1.1.12.1.19 | INTEGER | read-write | mandatory |
| rPDULoad OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.2 | |||
| rPDULoadDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.2.1 | |||
| rPDULoadDevMaxPhaseLoad OBJECT-TYPE Getting this OID will return the maximum rated power that each phase of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the unit is banked. | 1.3.6.1.4.1.318.1.1.12.2.1.1 | INTEGER | read-only | mandatory |
| rPDULoadDevNumPhases OBJECT-TYPE The number of phases available with this Rack PDU. | 1.3.6.1.4.1.318.1.1.12.2.1.2 | INTEGER | read-only | mandatory |
| rPDULoadDevMaxBankLoad OBJECT-TYPE Getting this OID will return the maximum rated power that a bank of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the device does not have any banks. | 1.3.6.1.4.1.318.1.1.12.2.1.3 | INTEGER | read-only | mandatory |
| rPDULoadDevNumBanks OBJECT-TYPE The number of banks of outlets available with this Rack PDU. A bank of outlets has a unique circuit breaker for a subset of the total number of outlets on the rPDU. 0 will be returned if the unit has no banks. | 1.3.6.1.4.1.318.1.1.12.2.1.4 | INTEGER | read-only | mandatory |
| rPDULoadDevBankTableSize OBJECT-TYPE The size of the Bank Table. | 1.3.6.1.4.1.318.1.1.12.2.1.5 | INTEGER | read-only | mandatory |
| rPDULoadDevBankTable OBJECT-TYPE Allows for getting the Bank Max Load in the Rack PDU. | 1.3.6.1.4.1.318.1.1.12.2.1.6 | not-accessible | mandatory | |
| rPDULoadDevBankEntry OBJECT-TYPE The Rack PDU Banks Access. | 1.3.6.1.4.1.318.1.1.12.2.1.6.1 | not-accessible | mandatory | |
| rPDULoadDevBankIndex OBJECT-TYPE The index to the Rack PDU bank entry. | 1.3.6.1.4.1.318.1.1.12.2.1.6.1.1 | INTEGER | read-only | mandatory |
| rPDULoadDevBankNumber OBJECT-TYPE Getting this OID will return the bank number. | 1.3.6.1.4.1.318.1.1.12.2.1.6.1.2 | INTEGER | read-only | mandatory |
| rPDULoadDevBankMaxLoad OBJECT-TYPE Getting this OID will return the maximum rated power that each bank of the Rack PDU can provide. It is represented in Amps. | 1.3.6.1.4.1.318.1.1.12.2.1.6.1.3 | INTEGER | read-only | mandatory |
| rPDULoadDevMaxOutletTableSize OBJECT-TYPE The size of the Outlet Table. | 1.3.6.1.4.1.318.1.1.12.2.1.7 | INTEGER | read-only | mandatory |
| rPDULoadDevMaxOutletTable OBJECT-TYPE Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU. | 1.3.6.1.4.1.318.1.1.12.2.1.8 | not-accessible | mandatory | |
| rPDULoadDevMaxOutletEntry OBJECT-TYPE This gives access to Max Outlet Load of an Outlet Monitored Rack PDU | 1.3.6.1.4.1.318.1.1.12.2.1.8.1 | not-accessible | mandatory | |
| rPDULoadDevOutletIndex OBJECT-TYPE The index to the Outlet Monitored Rack PDU Max Outlet Load entry. | 1.3.6.1.4.1.318.1.1.12.2.1.8.1.1 | INTEGER | read-only | mandatory |
| rPDULoadDevOutletNumber OBJECT-TYPE Getting this OID will return the Outlet number. | 1.3.6.1.4.1.318.1.1.12.2.1.8.1.2 | INTEGER | read-only | mandatory |
| rPDULoadDevMaxOutletLoad OBJECT-TYPE Getting this OID will return the maximum rated power that each Outlet of an Outlet Monitored Rack PDU can provide. It is represented in Amps. | 1.3.6.1.4.1.318.1.1.12.2.1.8.1.3 | INTEGER | read-only | mandatory |
| rPDULoadPhaseConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.2.2 | |||
| rPDULoadPhaseConfigTable OBJECT-TYPE Allows for configuration of each Rack PDU phase. The number of entries is contained in the rPDULoadDevNumPhases OID. | 1.3.6.1.4.1.318.1.1.12.2.2.1 | not-accessible | mandatory | |
| rPDULoadPhaseConfigEntry OBJECT-TYPE The Rack PDU phase to configure. | 1.3.6.1.4.1.318.1.1.12.2.2.1.1 | not-accessible | mandatory | |
| rPDULoadPhaseConfigIndex OBJECT-TYPE The index to the Rack PDU phase entry. | 1.3.6.1.4.1.318.1.1.12.2.2.1.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| rPDULoadPhaseConfigLowLoadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDULoadPhaseConfigNearOverloadThreshold OID. | 1.3.6.1.4.1.318.1.1.12.2.2.1.1.2 | INTEGER | read-write | mandatory |
| rPDULoadPhaseConfigNearOverloadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDULoadPhaseConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadPhaseConfigOverloadThreshold OID. | 1.3.6.1.4.1.318.1.1.12.2.2.1.1.3 | INTEGER | read-write | mandatory |
| rPDULoadPhaseConfigOverloadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDULoadPhaseConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxPhaseLoad OID. | 1.3.6.1.4.1.318.1.1.12.2.2.1.1.4 | INTEGER | read-write | mandatory |
| rPDULoadPhaseConfigAlarm OBJECT-TYPE Getting this OID will return the current Phase Alarm. | 1.3.6.1.4.1.318.1.1.12.2.2.1.1.5 | INTEGER {noLoadAlarm(1), underCurrentAlarm(2), nearOverCurrentAlarm(3), overCurrentAlarm(4)} | read-only | mandatory |
| rPDULoadStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.2.3 | |||
| rPDULoadStatusTable OBJECT-TYPE Allows for getting of status of each Rack PDU phase/bank. The number of entries is calculated by adding the number of phases (rPDULoadDevNumPhases OID) and the number of banks of outlets (rPDULoadDevNumBanks) Number of entries = #phases + #banks. NOTE: If a device has phase and bank information, all phase information shall precede the bank information. If a device has total information, it shall precede both the bank and the phase information. | 1.3.6.1.4.1.318.1.1.12.2.3.1 | not-accessible | mandatory | |
| rPDULoadStatusEntry OBJECT-TYPE The Rack PDU phase/bank to gather status from. | 1.3.6.1.4.1.318.1.1.12.2.3.1.1 | not-accessible | mandatory | |
| rPDULoadStatusIndex OBJECT-TYPE The index to the Rack PDU phase/bank entry. All phase information will precede any bank information | 1.3.6.1.4.1.318.1.1.12.2.3.1.1.1 | INTEGER | read-only | mandatory |
| rPDULoadStatusLoad OBJECT-TYPE Getting this OID will return the phase/bank load measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.12.2.3.1.1.2 | Gauge | read-only | mandatory |
| rPDULoadStatusLoadState OBJECT-TYPE Getting this OID will return the phase/bank load state. phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoadThreshold and rPDULoadConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the phase/bank load has dropped below the rPDULoadConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. | 1.3.6.1.4.1.318.1.1.12.2.3.1.1.3 | INTEGER {phaseLoadNormal(1), phaseLoadLow(2), phaseLoadNearOverload(3), phaseLoadOverload(4)} | read-only | mandatory |
| rPDULoadStatusPhaseNumber OBJECT-TYPE The phase number to which this record refers. | 1.3.6.1.4.1.318.1.1.12.2.3.1.1.4 | INTEGER | read-only | mandatory |
| rPDULoadStatusBankNumber OBJECT-TYPE The bank number to which this record refers. A value of 0 will be returned if any bank is not present or if it is phase related. | 1.3.6.1.4.1.318.1.1.12.2.3.1.1.5 | INTEGER | read-only | mandatory |
| rPDULoadBankConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.2.4 | |||
| rPDULoadBankConfigTable OBJECT-TYPE Allows for configuration of each Rack PDU bank. The number of entries is contained in the rPDULoadDevNumBanks OID. | 1.3.6.1.4.1.318.1.1.12.2.4.1 | not-accessible | mandatory | |
| rPDULoadBankConfigEntry OBJECT-TYPE The Rack PDU bank to configure. | 1.3.6.1.4.1.318.1.1.12.2.4.1.1 | not-accessible | mandatory | |
| rPDULoadBankConfigIndex OBJECT-TYPE The index to the Rack PDU bank entry. | 1.3.6.1.4.1.318.1.1.12.2.4.1.1.1 | INTEGER | read-only | mandatory |
| rPDULoadBankConfigLowLoadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDULoadBankConfigNearOverloadThreshold OID. | 1.3.6.1.4.1.318.1.1.12.2.4.1.1.2 | INTEGER | read-write | mandatory |
| rPDULoadBankConfigNearOverloadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDULoadBankConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadBankConfigOverloadThreshold OID. | 1.3.6.1.4.1.318.1.1.12.2.4.1.1.3 | INTEGER | read-write | mandatory |
| rPDULoadBankConfigOverloadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDULoadBankConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxBankLoad OID. | 1.3.6.1.4.1.318.1.1.12.2.4.1.1.4 | INTEGER | read-write | mandatory |
| rPDULoadBankConfigAlarm OBJECT-TYPE Getting this OID will return the current Bank Alarm. | 1.3.6.1.4.1.318.1.1.12.2.4.1.1.5 | INTEGER {noLoadAlarm(1), underCurrentAlarm(2), nearOverCurrentAlarm(3), overCurrentAlarm(4)} | read-only | mandatory |
| rPDUOutlet OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3 | |||
| rPDUOutletDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3.1 | |||
| rPDUOutletDevCommand OBJECT-TYPE Setting this OID to immediateAllOn (2) will turn all outlets on immediately. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will reboot all outlets immediately. Setting this OID to delayedAllOn (5) will turn all outlets on as defined by each outlet's rPDUOutletConfigPowerOnTime OID value. Setting this OID to delayedAllOff (6) will turn all outlets off as defined by each outlet's rPDUOutletConfigPowerOffTime OID value. Setting this OID to delayedAllReboot (7) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest rPDUOutletConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be canceled. Getting this OID will return the noCommandAll (1) value. | 1.3.6.1.4.1.318.1.1.12.3.1.1 | INTEGER {noCommandAll(1), immediateAllOn(2), immediateAllOff(3), immediateAllReboot(4), delayedAllOn(5), delayedAllOff(6), delayedAllReboot(7), cancelAllPendingCommands(8)} | read-write | mandatory |
| rPDUOutletDevColdstartDelay OBJECT-TYPE The amount of delay, in seconds, between when power is provided to the Switched Rack PDU and when the Switched Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes). | 1.3.6.1.4.1.318.1.1.12.3.1.2 | INTEGER | read-write | mandatory |
| rPDUOutletDevNumCntrlOutlets OBJECT-TYPE The number of controlled outlets on this Switched Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.1.3 | INTEGER | read-only | mandatory |
| rPDUOutletDevNumTotalOutlets OBJECT-TYPE The total number of outlets on this Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.1.4 | INTEGER | read-only | mandatory |
| rPDUOutletDevMonitoredOutlets OBJECT-TYPE The total number of monitored outlets on this Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.1.5 | INTEGER | read-only | mandatory |
| rPDUOutletPhase OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3.2 | |||
| rPDUOutletPhaseTable OBJECT-TYPE Allows for management of outlets on a per phase basis. | 1.3.6.1.4.1.318.1.1.12.3.2.1 | not-accessible | mandatory | |
| rPDUOutletPhaseEntry OBJECT-TYPE The phase to manage. | 1.3.6.1.4.1.318.1.1.12.3.2.1.1 | not-accessible | mandatory | |
| rPDUOutletPhaseIndex OBJECT-TYPE The index to the Switched Rack PDU phase entry. | 1.3.6.1.4.1.318.1.1.12.3.2.1.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| rPDUOutletPhaseOverloadRestriction OBJECT-TYPE This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigOverloadThreshold OID is exceeded. | 1.3.6.1.4.1.318.1.1.12.3.2.1.1.2 | INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3)} | read-write | mandatory |
| rPDUOutletControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3.3 | |||
| rPDUOutletControlTable OBJECT-TYPE Allows for control of the individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID. | 1.3.6.1.4.1.318.1.1.12.3.3.1 | not-accessible | mandatory | |
| rPDUOutletControlEntry OBJECT-TYPE The outlet to control. | 1.3.6.1.4.1.318.1.1.12.3.3.1.1 | not-accessible | mandatory | |
| rPDUOutletControlIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.12.3.3.1.1.1 | INTEGER | read-only | mandatory |
| rPDUOutletControlOutletName OBJECT-TYPE The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.12.3.3.1.1.2 | DisplayString | read-only | mandatory |
| rPDUOutletControlOutletPhase OBJECT-TYPE The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1. | 1.3.6.1.4.1.318.1.1.12.3.3.1.1.3 | INTEGER {phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)} | read-only | mandatory |
| rPDUOutletControlOutletCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will immediately reboot the outlet. Setting this variable to delayedOn (4) will turn the outlet on after the rPDUOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (5) will turn the outlet off after the rPDUOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched Rack PDU to perform a delayedOff command, wait the rPDUOutletConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (7) will cause any pending command to this outlet to be canceled. | 1.3.6.1.4.1.318.1.1.12.3.3.1.1.4 | INTEGER {immediateOn(1), immediateOff(2), immediateReboot(3), delayedOn(4), delayedOff(5), delayedReboot(6), cancelPendingCommand(7)} | read-write | mandatory |
| rPDUOutletControlOutletBank OBJECT-TYPE The bank associated with this outlet. | 1.3.6.1.4.1.318.1.1.12.3.3.1.1.5 | INTEGER | read-only | mandatory |
| rPDUOutletConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3.4 | |||
| rPDUOutletConfigTable OBJECT-TYPE Allows for configuration of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID. | 1.3.6.1.4.1.318.1.1.12.3.4.1 | not-accessible | mandatory | |
| rPDUOutletConfigEntry OBJECT-TYPE The outlet to configure. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1 | not-accessible | mandatory | |
| rPDUOutletConfigIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.1 | INTEGER | read-only | mandatory |
| rPDUOutletConfigOutletName OBJECT-TYPE The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.2 | DisplayString | read-write | mandatory |
| rPDUOutletConfigOutletPhase OBJECT-TYPE The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.3 | INTEGER {phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)} | read-only | mandatory |
| rPDUOutletConfigPowerOnTime OBJECT-TYPE The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 - power on immediately. 1 to 7200 - power on up to 7200 seconds after being commanded. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.4 | INTEGER | read-write | mandatory |
| rPDUOutletConfigPowerOffTime OBJECT-TYPE The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - power off immediately. 1 to 7200 - power off up to 7200 seconds after being commanded. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.5 | INTEGER | read-write | mandatory |
| rPDUOutletConfigRebootDuration OBJECT-TYPE During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute). | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.6 | INTEGER | read-write | mandatory |
| rPDUOutletConfigOutletBank OBJECT-TYPE The bank associated with this outlet. | 1.3.6.1.4.1.318.1.1.12.3.4.1.1.7 | INTEGER | read-only | mandatory |
| rPDUOutletConfigMonitoredTableSize OBJECT-TYPE The size of the Outlet Config Monitored Table | 1.3.6.1.4.1.318.1.1.12.3.4.2 | INTEGER | read-only | mandatory |
| rPDUOutletConfigMonitoredTable OBJECT-TYPE Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.4.3 | not-accessible | mandatory | |
| rPDUOutletConfigMonitoredEntry OBJECT-TYPE This gives access to Monitored Outlet entries | 1.3.6.1.4.1.318.1.1.12.3.4.3.1 | not-accessible | mandatory | |
| rPDUOutletConfigMonitoredIndex OBJECT-TYPE The index to the RACK PDU Phase entry. | 1.3.6.1.4.1.318.1.1.12.3.4.3.1.1 | INTEGER | read-only | mandatory |
| rPDUOutletConfigMonitoredName OBJECT-TYPE The name of the Monitored Outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. | 1.3.6.1.4.1.318.1.1.12.3.4.3.1.2 | DisplayString | read-write | mandatory |
| rPDUOutletConfigMonitoredNumber OBJECT-TYPE The outlet number of an Outlet Monitored RACK PDU. | 1.3.6.1.4.1.318.1.1.12.3.4.3.1.3 | INTEGER | read-only | mandatory |
| rPDUOutletConfigMonitoredLowLoadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.4.3.1.4 | INTEGER | read-write | mandatory |
| rPDUOutletConfigMonitoredNearOverloadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDUOutletConfigMonitoredLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDUOutletConfigMonitoredOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.4.3.1.5 | INTEGER | read-write | mandatory |
| rPDUOutletConfigMonitoredOverloadThreshold OBJECT-TYPE A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxOutletLoad OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU. | 1.3.6.1.4.1.318.1.1.12.3.4.3.1.6 | INTEGER | read-write | mandatory |
| rPDUOutletStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3.5 | |||
| rPDUOutletStatusTable OBJECT-TYPE Allows for getting of status of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID or rPDUOutletDevMonitoredOutlets OID. | 1.3.6.1.4.1.318.1.1.12.3.5.1 | not-accessible | mandatory | |
| rPDUOutletStatusEntry OBJECT-TYPE The outlet to gather status from. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1 | not-accessible | mandatory | |
| rPDUOutletStatusIndex OBJECT-TYPE The index to the outlet entry. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.1 | INTEGER | read-only | mandatory |
| rPDUOutletStatusOutletName OBJECT-TYPE The name of the outlet. The maximum string size is device dependent. This OID is provided for informational purposes only. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.2 | DisplayString | read-only | mandatory |
| rPDUOutletStatusOutletPhase OBJECT-TYPE The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.3 | INTEGER {phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)} | read-only | mandatory |
| rPDUOutletStatusOutletState OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusOff (2) value will be returned. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.4 | INTEGER {outletStatusOn(1), outletStatusOff(2)} | read-only | mandatory |
| rPDUOutletStatusCommandPending OBJECT-TYPE Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.5 | INTEGER {outletStatusCommandPending(1), outletStatusNoCommandPending(2)} | read-only | mandatory |
| rPDUOutletStatusOutletBank OBJECT-TYPE The bank associated with this outlet. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.6 | INTEGER | read-only | mandatory |
| rPDUOutletStatusLoad OBJECT-TYPE Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in tenths of Amps. For other models this OID is not supported. | 1.3.6.1.4.1.318.1.1.12.3.5.1.1.7 | Gauge | read-only | mandatory |
| rPDUOutletBank OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.3.6 | |||
| rPDUOutletBankTable OBJECT-TYPE Allows for management of outlets on a per bank basis. | 1.3.6.1.4.1.318.1.1.12.3.6.1 | not-accessible | mandatory | |
| rPDUOutletBankEntry OBJECT-TYPE The bank to manage. | 1.3.6.1.4.1.318.1.1.12.3.6.1.1 | not-accessible | mandatory | |
| rPDUOutletBankIndex OBJECT-TYPE The index to the Switched Rack PDU bank entry. | 1.3.6.1.4.1.318.1.1.12.3.6.1.1.1 | INTEGER | read-only | mandatory |
| rPDUOutletBankOverloadRestriction OBJECT-TYPE This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the rPDULoadBankConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the rPDULoadBankConfigOverloadThreshold OID is exceeded. | 1.3.6.1.4.1.318.1.1.12.3.6.1.1.2 | INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3)} | read-write | mandatory |
| rPDUPowerSupply OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.4 | |||
| rPDUPowerSupplyDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.4.1 | |||
| rPDUPowerSupply1Status OBJECT-TYPE Getting this OID will return powerSupply1Ok(1) if power supply 1 is functioning normally. If not functioning normally, this OID will return powerSupply1Failed(2). | 1.3.6.1.4.1.318.1.1.12.4.1.1 | INTEGER {powerSupplyOneOk(1), powerSupplyOneFailed(2)} | read-only | mandatory |
| rPDUPowerSupply2Status OBJECT-TYPE Getting this OID will return powerSupply2Ok(1) if power supply 2 is functioning normally. If not functioning normally, this OID will return powerSupply2Failed(2). Metered Rack PDUs do not have a redundant powersupply. | 1.3.6.1.4.1.318.1.1.12.4.1.2 | INTEGER {powerSupplyTwoOk(1), powerSupplyTwoFailed(2), powerSupplyTwoNotPresent(3)} | read-only | mandatory |
| rPDUPowerSupplyAlarm OBJECT-TYPE Getting this OID will return powerSupply Alarm | 1.3.6.1.4.1.318.1.1.12.4.1.3 | INTEGER {allAvailablePowerSuppliesOK(1), powerSupplyOneFailed(2), powerSupplyTwoFailed(3), powerSupplyOneandTwoFailed(4)} | read-only | mandatory |
| rPDUStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.12.5 | |||
| rPDUStatusBankTableSize OBJECT-TYPE The size of the Status Bank Table | 1.3.6.1.4.1.318.1.1.12.5.1 | INTEGER | read-only | mandatory |
| rPDUStatusBankTable OBJECT-TYPE Allows for getting of status of each Rack PDU Bank | 1.3.6.1.4.1.318.1.1.12.5.2 | not-accessible | mandatory | |
| rPDUStatusBankEntry OBJECT-TYPE This gives access to Bank entries | 1.3.6.1.4.1.318.1.1.12.5.2.1 | not-accessible | mandatory | |
| rPDUStatusBankIndex OBJECT-TYPE The index to the RACK PDU Bank entry. | 1.3.6.1.4.1.318.1.1.12.5.2.1.1 | INTEGER | read-only | mandatory |
| rPDUStatusBankNumber OBJECT-TYPE Getting this OID will return the bank number. | 1.3.6.1.4.1.318.1.1.12.5.2.1.2 | INTEGER | read-only | mandatory |
| rPDUStatusBankState OBJECT-TYPE Getting this OID will return the bank load state. bankLoadNormal(1) indicates that the bank is operating properly within the rPDULoadBankConfigLowLoadThreshold and rPDULoadBankConfigNearOverloadThreshold OID values. bankLoadLow(2) indicates that the bank load has dropped below the rPDULoadBankConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadNearOverload(3) indicates that the bank load is greater than or equal to the rPDULoadBankConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadOverload(4) indicates that the bank load is greater than or equal to the rPDULoadBankConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. | 1.3.6.1.4.1.318.1.1.12.5.2.1.3 | INTEGER {bankLoadNormal(1), bankLoadLow(2), bankLoadNearOverload(3), bankLoadOverload(4)} | read-only | mandatory |
| rPDUStatusPhaseTableSize OBJECT-TYPE The size of the Status Phase Table | 1.3.6.1.4.1.318.1.1.12.5.3 | INTEGER | read-only | mandatory |
| rPDUStatusPhaseTable OBJECT-TYPE Allows for getting of status of each Rack PDU Phase | 1.3.6.1.4.1.318.1.1.12.5.4 | not-accessible | mandatory | |
| rPDUStatusPhaseEntry OBJECT-TYPE This gives access to Phase entries | 1.3.6.1.4.1.318.1.1.12.5.4.1 | not-accessible | mandatory | |
| rPDUStatusPhaseIndex OBJECT-TYPE The index to the RACK PDU Phase entry. | 1.3.6.1.4.1.318.1.1.12.5.4.1.1 | INTEGER | read-only | mandatory |
| rPDUStatusPhaseNumber OBJECT-TYPE Getting this OID will return the phase number. | 1.3.6.1.4.1.318.1.1.12.5.4.1.2 | INTEGER | read-only | mandatory |
| rPDUStatusPhaseState OBJECT-TYPE Getting this OID will return the Phase load state. phaseLoadNormal(1) indicates that the Phase is operating properly within the rPDULoadPhaseConfigLowLoadThreshold and rPDULoadPhaseConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the Phase load has dropped below the rPDULoadPhaseConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the Phase load is greater than or equal to the rPDULoadPhaseConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the Phase load is greater than or equal to the rPDULoadPhaseConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. | 1.3.6.1.4.1.318.1.1.12.5.4.1.3 | INTEGER {phaseLoadNormal(1), phaseLoadLow(2), phaseLoadNearOverload(3), phaseLoadOverload(4)} | read-only | mandatory |
| rPDUStatusOutletTableSize OBJECT-TYPE The size of the Status Outlet Table | 1.3.6.1.4.1.318.1.1.12.5.5 | INTEGER | read-only | mandatory |
| rPDUStatusOutletTable OBJECT-TYPE Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU. | 1.3.6.1.4.1.318.1.1.12.5.6 | not-accessible | mandatory | |
| rPDUStatusOutletEntry OBJECT-TYPE This gives access to Outlet entries | 1.3.6.1.4.1.318.1.1.12.5.6.1 | not-accessible | mandatory | |
| rPDUStatusOutletIndex OBJECT-TYPE The index to the RACK PDU Outlet entry. | 1.3.6.1.4.1.318.1.1.12.5.6.1.1 | INTEGER | read-only | mandatory |
| rPDUStatusOutletNumber OBJECT-TYPE Getting this OID will return the Outlet number. | 1.3.6.1.4.1.318.1.1.12.5.6.1.2 | INTEGER | read-only | mandatory |
| rPDUStatusOutletState OBJECT-TYPE Getting this OID will return the Outlet load state. outletLoadNormal(1) indicates that the Outlet is operating properly within the rPDUOutletConfigMonitoredLowLoadThreshold and rPDUOutletConfigMonitoredNearOverloadThreshold OID values. outletLoadLow(2) indicates that the Outlet load has dropped below the rPDUOutletConfigMonitoredLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadNearOverload(3) indicates that the Outlet load is greater than or equal to the rPDUOutletConfigMonitoredNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadOverload(4) indicates that the Outlet load is greater than or equal to the rPDUOutletConfigMonitoredOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. | 1.3.6.1.4.1.318.1.1.12.5.6.1.3 | INTEGER {outletLoadNormal(1), outletLoadLow(2), outletLoadNearOverload(3), outletLoadOverload(4)} | read-only | mandatory |
| airConditioners OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13 | |||
| airFM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1 | |||
| airFMIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.1 | |||
| airFMIdentName OBJECT-TYPE A character string identifying the device. | 1.3.6.1.4.1.318.1.1.13.1.1.1 | DisplayString | read-write | mandatory |
| airFMIdentTableSize OBJECT-TYPE The number of entries in the airFMIdentTable. | 1.3.6.1.4.1.318.1.1.13.1.1.2 | INTEGER | read-only | mandatory |
| airFMIdentTable OBJECT-TYPE Allows for getting identification information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.1.3 | not-accessible | mandatory | |
| airFMIdentEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1 | not-accessible | mandatory | |
| airFMIdentModuleIndex OBJECT-TYPE The index of the module information. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1.1 | INTEGER | read-only | mandatory |
| airFMIdentModuleModelNumber OBJECT-TYPE A character string identifying the model number. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1.2 | DisplayString | read-only | mandatory |
| airFMIdentModuleDateOfMfg OBJECT-TYPE A character string identifying the manufacture date. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1.3 | DisplayString | read-only | mandatory |
| airFMIdentModuleSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1.4 | DisplayString | read-only | mandatory |
| airFMIdentModuleFirmwareRev OBJECT-TYPE A character string identifying the firmware revision. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1.5 | DisplayString | read-only | mandatory |
| airFMIdentModuleHardwareRev OBJECT-TYPE A character string identifying the hardware revision. | 1.3.6.1.4.1.318.1.1.13.1.1.3.1.6 | DisplayString | read-only | mandatory |
| airFMIdentLocation OBJECT-TYPE A character string identifying the location of the device. | 1.3.6.1.4.1.318.1.1.13.1.1.4 | DisplayString | read-write | mandatory |
| airFMIdentContact OBJECT-TYPE A character string identifying the person to contact regarding the device. | 1.3.6.1.4.1.318.1.1.13.1.1.5 | DisplayString | read-write | mandatory |
| airFMStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.2 | |||
| airFMStatusSystemOn OBJECT-TYPE The operating state of the system. This OID has been deprecated in favor of airFMGroupSysStatus. | 1.3.6.1.4.1.318.1.1.13.1.2.1 | INTEGER {statusOn(1), statusOff(2)} | read-only | mandatory |
| airFMStatusSystemAverageRetTempC OBJECT-TYPE The system average return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgReturnTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.2 | INTEGER | read-only | mandatory |
| airFMStatusSystemAverageRetTempF OBJECT-TYPE The system average return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgReturnTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.3 | INTEGER | read-only | mandatory |
| airFMStatusSystemAverageRetHum OBJECT-TYPE The system average return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgReturnHum. | 1.3.6.1.4.1.318.1.1.13.1.2.4 | INTEGER | read-only | mandatory |
| airFMStatusSystemActionTempC OBJECT-TYPE The system action air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysCtrlTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.5 | INTEGER | read-only | mandatory |
| airFMStatusSystemActionTempF OBJECT-TYPE The system action air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysCtrlTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.6 | INTEGER | read-only | mandatory |
| airFMStatusSystemActionHum OBJECT-TYPE The system action air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysCtrlHum. | 1.3.6.1.4.1.318.1.1.13.1.2.7 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteHighTempC OBJECT-TYPE The system remote high air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMaxRemoteTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.8 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteHighTempF OBJECT-TYPE The system remote high air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMaxRemoteTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.9 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteAvgTempC OBJECT-TYPE The system remote average air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgRemoteTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.10 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteAvgTempF OBJECT-TYPE The system remote average air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgRemoteTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.11 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteAvgHum OBJECT-TYPE The system remote average air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgRemoteHum. | 1.3.6.1.4.1.318.1.1.13.1.2.12 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteLowTempC OBJECT-TYPE The system remote low air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMinRemoteTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.13 | INTEGER | read-only | mandatory |
| airFMStatusSystemRemoteLowTempF OBJECT-TYPE The system remote low air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMinRemoteTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.14 | INTEGER | read-only | mandatory |
| airFMStatusSystemCoolingEnabled OBJECT-TYPE The state of the system cooling function enable. This OID has been deprecated in favor of airFMSysCoolState. | 1.3.6.1.4.1.318.1.1.13.1.2.15 | INTEGER {enabledYes(1), enabledNo(2)} | read-only | mandatory |
| airFMStatusSystemReheatingEnabled OBJECT-TYPE The state of the system reheating function enable. This OID has been deprecated in favor of airFMSysReheatState. | 1.3.6.1.4.1.318.1.1.13.1.2.16 | INTEGER {enabledYes(1), enabledNo(2)} | read-only | mandatory |
| airFMStatusSystemHumidifyEnabled OBJECT-TYPE The state of the system humidify function enable. This OID has been deprecated in favor of airFMSysHumState. | 1.3.6.1.4.1.318.1.1.13.1.2.17 | INTEGER {enabledYes(1), enabledNo(2)} | read-only | mandatory |
| airFMStatusSystemDehumidifyEnabled OBJECT-TYPE The state of the system dehumidify function enable. This OID has been deprecated in favor of airFMSysDehumState. | 1.3.6.1.4.1.318.1.1.13.1.2.18 | INTEGER {enabledYes(1), enabledNo(2)} | read-only | mandatory |
| airFMStatusModuleTableSize OBJECT-TYPE The number of entries in the airFMStatusModuleTable. | 1.3.6.1.4.1.318.1.1.13.1.2.19 | INTEGER | read-only | mandatory |
| airFMStatusModuleTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.2.20 | not-accessible | mandatory | |
| airFMStatusModuleEntry OBJECT-TYPE The module to get status from. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1 | not-accessible | mandatory | |
| airFMStatusModuleIndex OBJECT-TYPE The index of the module information. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.1 | INTEGER | read-only | mandatory |
| airFMStatusModuleOutputCapacity OBJECT-TYPE The module output capacity in kilowatts. This OID has been deprecated in favor of airFMModOutputCapacity. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.2 | INTEGER | read-only | mandatory |
| airFMStatusModuleSupplyTempC OBJECT-TYPE The module supply air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModSupplyTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.3 | INTEGER | read-only | mandatory |
| airFMStatusModuleSupplyTempF OBJECT-TYPE The module supply air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModSupplyTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.4 | INTEGER | read-only | mandatory |
| airFMStatusModuleSupplyHum OBJECT-TYPE The module supply air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModSupplyHum. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.5 | INTEGER | read-only | mandatory |
| airFMStatusModuleReturnTempC OBJECT-TYPE The module return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModReturnTempC. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.6 | INTEGER | read-only | mandatory |
| airFMStatusModuleReturnTempF OBJECT-TYPE The module return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModReturnTempF. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.7 | INTEGER | read-only | mandatory |
| airFMStatusModuleReturnHum OBJECT-TYPE The module return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModReturnHum. | 1.3.6.1.4.1.318.1.1.13.1.2.20.1.8 | INTEGER | read-only | mandatory |
| airFMGroup OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3 | |||
| airFMGroupSysStatus OBJECT-TYPE The status of this system within the group. | 1.3.6.1.4.1.318.1.1.13.1.3.1 | INTEGER {statusOnLine(1), statusIdle(2), statusLoadShare(3), statusOffLine(4), statusFailed(5), statusDisabled(6), statusUndefined(7)} | read-only | mandatory |
| airFMGroupSysRuntime OBJECT-TYPE The number of hours the system has been running. | 1.3.6.1.4.1.318.1.1.13.1.3.2 | INTEGER | read-only | mandatory |
| airFMGroupSysRole OBJECT-TYPE The role of this system within the group. | 1.3.6.1.4.1.318.1.1.13.1.3.3 | INTEGER {rolePrimary(1), roleBackup(2)} | read-only | mandatory |
| airFMGroupSysRoles OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3.4 | |||
| airFMGroupSysRolesTableSize OBJECT-TYPE The number of entries in the airFMGroupSysRolesTable. | 1.3.6.1.4.1.318.1.1.13.1.3.4.1 | INTEGER | read-only | mandatory |
| airFMGroupSysRolesTable OBJECT-TYPE Allows for getting information from each system in the group. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2 | not-accessible | mandatory | |
| airFMGroupSysRolesEntry OBJECT-TYPE The system to get status from. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1 | not-accessible | mandatory | |
| airFMGroupSysIndex OBJECT-TYPE The index of the system information. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.1 | INTEGER | read-only | mandatory |
| airFMGroupSysRoleStatus OBJECT-TYPE The present mode of the System. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.2 | INTEGER {reserved1(1), reserved2(2), onLine(3), idle(4), loadShare(5), failed(6), offLine(7)} | read-only | mandatory |
| airFMGroupSysPresentRole OBJECT-TYPE The present role of the System in a Group. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.3 | INTEGER {primary(1), backup(2)} | read-only | mandatory |
| airFMGroupSysManualRoleSetting OBJECT-TYPE The manual role setting of the System in a Group. Only applies if Role Assignment Method is set to static (Manually Assigned Roles). | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.4 | INTEGER {primary(1), backup(2)} | read-write | mandatory |
| airFMGroupSysRunHours OBJECT-TYPE The total number of hours the System has been contributing to environmental control. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.5 | INTEGER | read-only | mandatory |
| airFMGroupSysComm OBJECT-TYPE Indicates whether a system is communicating with the other Systems in the Group. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.6 | INTEGER {commLost(1), commEstablished(2)} | read-only | mandatory |
| airFMGroupSysIPAddress OBJECT-TYPE The IP Address of the System. | 1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.7 | IpAddress | read-only | mandatory |
| airFMGroupSysRoleAssignment OBJECT-TYPE The method used to assign roles (i.e. Primary, Backup) to the Systems in a Group. staticManual: Manually assign Primary or Backup to regulate run hours across the Group. dynamicAutomatic: User indicates the number of Systems that will be assigned a primary role in this Group. | 1.3.6.1.4.1.318.1.1.13.1.3.4.3 | INTEGER {staticManual(1), dynamicAutomatic(2)} | read-write | mandatory |
| airFMGroupAutoRoleNumPrimary OBJECT-TYPE The number of Systems assigned the 'primary' role in this Group. Only applies if Role Assignment Method is set to dynamic (Automatic Run Hour Balancing). | 1.3.6.1.4.1.318.1.1.13.1.3.4.4 | INTEGER {one(1), two(2), three(3), four(4)} | read-write | mandatory |
| airFMGroupCfg OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3.5 | |||
| airFMGroupCfgName OBJECT-TYPE A character string identifying the group name. | 1.3.6.1.4.1.318.1.1.13.1.3.5.1 | DisplayString | read-write | mandatory |
| airFMGroupCfgNumSystems OBJECT-TYPE The number of Systems in this Group. | 1.3.6.1.4.1.318.1.1.13.1.3.5.2 | INTEGER {one(1), two(2), three(3), four(4)} | read-write | mandatory |
| airFMGroupCfgIdleBlower OBJECT-TYPE Blower behavior for backup Systems and Systems that have entered a failure mode. | 1.3.6.1.4.1.318.1.1.13.1.3.5.3 | INTEGER {off(1), minimumSpeed(2), normalSpeed(3)} | read-write | mandatory |
| airFMGroupCfgShutdownSmoke OBJECT-TYPE If enabled, all Systems in the Group will shut down if smoke is detected. | 1.3.6.1.4.1.318.1.1.13.1.3.5.4 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupCfgShutdownFire OBJECT-TYPE If enabled, all Systems in the Group will shut down if fire is detected. | 1.3.6.1.4.1.318.1.1.13.1.3.5.5 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupCfgFailoverCommLoss OBJECT-TYPE Failover on Comm Loss enables an available backup System to run in place of a System that has lost communication with the Group. | 1.3.6.1.4.1.318.1.1.13.1.3.5.6 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupCfgDmdFightStatus OBJECT-TYPE Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to a Load Sharing Request. | 1.3.6.1.4.1.318.1.1.13.1.3.5.7 | INTEGER {off(1), on(2)} | read-only | mandatory |
| airFMGroupCfgDmdFightSetting OBJECT-TYPE Demand Fighting prevents a System from engaging reheat in a Group where any System is cooling. | 1.3.6.1.4.1.318.1.1.13.1.3.5.8 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupCfgSetpointShareStatus OBJECT-TYPE Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to Load Sharing Request. | 1.3.6.1.4.1.318.1.1.13.1.3.5.9 | INTEGER {off(1), on(2)} | read-only | mandatory |
| airFMGroupCfgSetpointShareSetting OBJECT-TYPE All Systems in the Group use the same setpoints. | 1.3.6.1.4.1.318.1.1.13.1.3.5.10 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupCfgResetFieldServiceDefaults OBJECT-TYPE Setting this OID to reset(2) will reset all Group parameters, which can only be edited by a field service engineer, to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.13.1.3.5.11 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| airFMGroupLoadShare OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3.6 | |||
| airFMGroupLoadShareCoolRequests OBJECT-TYPE Systems that are cooling may request assistance from other Systems in the Group. | 1.3.6.1.4.1.318.1.1.13.1.3.6.1 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupLoadShareCoolThreshC OBJECT-TYPE Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.1.3.6.2 | INTEGER | read-write | mandatory |
| airFMGroupLoadShareCoolThreshF OBJECT-TYPE Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.1.3.6.3 | INTEGER | read-write | mandatory |
| airFMGroupLoadShareReheatRequests OBJECT-TYPE Systems that are reheating may request assistance from other Systems in the Group. | 1.3.6.1.4.1.318.1.1.13.1.3.6.4 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupLoadShareReheatThreshC OBJECT-TYPE Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.1.3.6.5 | INTEGER | read-write | mandatory |
| airFMGroupLoadShareReheatThreshF OBJECT-TYPE Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.1.3.6.6 | INTEGER | read-write | mandatory |
| airFMGroupLoadShareHumRequests OBJECT-TYPE Systems that are humidifying may request humidification assistance from other Systems in the Group. | 1.3.6.1.4.1.318.1.1.13.1.3.6.7 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupLoadShareHumThresh OBJECT-TYPE Humidity threshold at which a System will generate a load sharing request for humidification. Measured in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.1.3.6.8 | INTEGER | read-write | mandatory |
| airFMGroupLoadShareDehumRequests OBJECT-TYPE Systems that are dehumidifying may request assistance from other Systems in the Group. | 1.3.6.1.4.1.318.1.1.13.1.3.6.9 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airFMGroupLoadShareDehumThresh OBJECT-TYPE Humidity threshold at which a System will generate a load sharing request for dehumidification. Measured in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.1.3.6.10 | INTEGER | read-write | mandatory |
| airFMGroupFailover OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3.7 | |||
| airFMGroupFailoverSys OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3.7.1 | |||
| airFMGroupFailoverSysAnyMinorAlarm OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if any minor system alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.1 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysAnyMajorAlarm OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if any major system alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.2 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysHighEnvTemp OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the high environmental temperature alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.3 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysLowEnvTemp OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the low environmental temperature alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.4 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysHighEnvHum OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the high environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.5 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysLowEnvHum OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the low environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.6 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysFireAlarm OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the fire alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.7 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysSmokeAlarm OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the smoke alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.8 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysCommLost OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the system has lost comm. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.9 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysSupplySensorFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the supply sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.10 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysReturnSensorFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the return sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.11 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysPrimarySensorFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the primary sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.12 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysSecondarySensorFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the secondary sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.13 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverSysNoSensorsAvailable OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if no sensors are available. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.1.14 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverMod OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.3.7.2 | |||
| airFMGroupFailoverModMaintRequired OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if maintenance is required on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.1 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModCoolFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if cooling has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.2 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModHumFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the humidifier has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.3 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModBlwrCntrl1Fail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if blower controller 1 has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.4 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModBlwrCntrl2Fail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if blower controller 2 has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.5 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModHighFilterDP OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if a high filter differential pressure is present on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.6 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModHighSupplyTemp OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if a high supply temperature is active on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.7 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModLowSupplyTemp OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if a low supply temperature is active on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.8 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModLossOrLowAirFlow OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if there is a loss of air flow or low air flow on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.9 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModHumReplaceCylinder OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if a humidifier needs its cylinder replaced on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.10 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModAirBlockInterlockOpen OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the air block interlock is open on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.11 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModWaterDetected OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if water is detected by a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.12 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMGroupFailoverModCondensatePumpFail OBJECT-TYPE Enabling this OID will cause the system to enter a failure state if the condensate pump has failed in a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.3.7.2.13 | INTEGER {notApplicable(1), disable(2), enable(3)} | read-write | mandatory |
| airFMSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4 | |||
| airFMSysStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.1 | |||
| airFMSysNumber OBJECT-TYPE The number of the system within the group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.1 | INTEGER {notApplicable(1), one(2), two(3), three(4), four(5)} | read-only | mandatory |
| airFMSysPresentStatus OBJECT-TYPE The present mode of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.2 | INTEGER {notApplicable(1), reserved1(2), reserved2(3), onLine(4), idle(5), loadShare(6), failed(7), offLine(8)} | read-only | mandatory |
| airFMSysPresentRole OBJECT-TYPE The present role of the System in the Group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.3 | INTEGER {notApplicable(1), primary(2), backup(3)} | read-only | mandatory |
| airFMSysRunHours OBJECT-TYPE The total number of hours the System has been contributing to environmental control. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.4 | INTEGER | read-only | mandatory |
| airFMSysCoilFluidTempC OBJECT-TYPE The temperature of the coolant at the fluid coil inlet. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.5 | INTEGER | read-only | mandatory |
| airFMSysCoilFluidTempF OBJECT-TYPE The temperature of the coolant at the fluid coil inlet. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.6 | INTEGER | read-only | mandatory |
| airFMSysHotWaterTempC OBJECT-TYPE The hot water temperature. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.7 | INTEGER | read-only | mandatory |
| airFMSysHotWaterTempF OBJECT-TYPE The hot water temperature. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.8 | INTEGER | read-only | mandatory |
| airFMSysAvgReturnTempC OBJECT-TYPE The average return temperature calculated from all present modules. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.9 | INTEGER | read-only | mandatory |
| airFMSysAvgReturnTempF OBJECT-TYPE The average return temperature calculated from all present modules. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.10 | INTEGER | read-only | mandatory |
| airFMSysAvgReturnHum OBJECT-TYPE The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.11 | INTEGER | read-only | mandatory |
| airFMSysAvgRemoteTempC OBJECT-TYPE The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.12 | INTEGER | read-only | mandatory |
| airFMSysAvgRemoteTempF OBJECT-TYPE The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.13 | INTEGER | read-only | mandatory |
| airFMSysAvgRemoteHum OBJECT-TYPE The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.14 | INTEGER | read-only | mandatory |
| airFMSysMaxRemoteTempC OBJECT-TYPE The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.15 | INTEGER | read-only | mandatory |
| airFMSysMaxRemoteTempF OBJECT-TYPE The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.16 | INTEGER | read-only | mandatory |
| airFMSysMinRemoteTempC OBJECT-TYPE The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.17 | INTEGER | read-only | mandatory |
| airFMSysMinRemoteTempF OBJECT-TYPE The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.18 | INTEGER | read-only | mandatory |
| airFMSysTempCtrlMethod OBJECT-TYPE The method of environment temperature control selected to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.19 | INTEGER {notApplicable(1), avgReturn(2), avgRemote(3), maxRemote(4)} | read-only | mandatory |
| airFMSysActualTempCtrlMethod OBJECT-TYPE The actual method of environment temperature control being used to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.20 | INTEGER {notApplicable(1), avgReturn(2), avgRemote(3), maxRemote(4)} | read-only | mandatory |
| airFMSysHumCtrlMethod OBJECT-TYPE The method of environment humidity control selected to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.21 | INTEGER {notApplicable(1), avgReturnRH(2), avgReturnDewPt(3), avgRemoteRH(4), avgRemoteDewPt(5)} | read-only | mandatory |
| airFMSysActualHumCtrlMethod OBJECT-TYPE The actual method of environment humidity control being used to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.22 | INTEGER {notApplicable(1), avgReturnRH(2), avgReturnDewPt(3), avgRemoteRH(4), avgRemoteDewPt(5)} | read-only | mandatory |
| airFMSysCtrlTempC OBJECT-TYPE The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.23 | INTEGER | read-only | mandatory |
| airFMSysCtrlTempF OBJECT-TYPE The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.24 | INTEGER | read-only | mandatory |
| airFMSysCtrlHum OBJECT-TYPE The system environmental control air humidity from the sensor denoted by airFMSysActualHumCtrl. Measured in percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.1.25 | INTEGER | read-only | mandatory |
| airFMSysDemands OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.2 | |||
| airFMSysDXCoolingDmd OBJECT-TYPE The direct expansion cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.1 | INTEGER | read-only | mandatory |
| airFMSysDXDehumDmd OBJECT-TYPE The direct expansion dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.2 | INTEGER | read-only | mandatory |
| airFMSysDXActualCoolDehum OBJECT-TYPE The direct expansion cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.3 | INTEGER | read-only | mandatory |
| airFMSysCoilFluidCoolDmd OBJECT-TYPE The fluid coil cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.4 | INTEGER | read-only | mandatory |
| airFMSysCoilFluidDehumDmd OBJECT-TYPE The fluid coil dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.5 | INTEGER | read-only | mandatory |
| airFMSysCoilFluidActualCoolDehum OBJECT-TYPE The fluid coil cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.6 | INTEGER | read-only | mandatory |
| airFMSysElectricReheatDmd OBJECT-TYPE The electric reheating output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.7 | INTEGER | read-only | mandatory |
| airFMSysActualElectricReheat OBJECT-TYPE The electric reheating output of the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.8 | INTEGER | read-only | mandatory |
| airFMSysSteamHotGasReheatDmd OBJECT-TYPE The steam, hot water, or hot gas reheating output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.9 | INTEGER {notApplicable(1), off(2), on(3)} | read-only | mandatory |
| airFMSysActualSteamHotGasReheat OBJECT-TYPE The steam, hot water, or hot gas reheating output of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.10 | INTEGER {notApplicable(1), off(2), on(3)} | read-only | mandatory |
| airFMSysSteamElectrodeHumDmd OBJECT-TYPE The steam electrode humidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.11 | INTEGER | read-only | mandatory |
| airFMSysActualSteamElectrodeHum OBJECT-TYPE The average steam electrode humidification output measured for the Modules in the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.12 | INTEGER | read-only | mandatory |
| airFMSysSteamHumDmd OBJECT-TYPE The steam humidification output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.13 | INTEGER {notApplicable(1), off(2), on(3)} | read-only | mandatory |
| airFMSysActualSteamHum OBJECT-TYPE The steam humidification output for the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.2.14 | INTEGER {notApplicable(1), off(2), on(3)} | read-only | mandatory |
| airFMSysSetup OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.3 | |||
| airFMSysNumModules OBJECT-TYPE The number of Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.1 | INTEGER {notApplicable(1), one(2), two(3), three(4)} | read-only | mandatory |
| airFMSysNumPCIOMs OBJECT-TYPE The number of Programmable Customer Input/Output Modules (PCIOMs) installed in the Main Module of this System. Each PCIOM adds four input contacts and four output relays to the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.2 | INTEGER {notApplicable(1), one(2), two(3), three(4), four(5)} | read-only | mandatory |
| airFMSysMainsVlt OBJECT-TYPE The mains voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.3 | DisplayString | read-only | mandatory |
| airFMSysUPSVlt OBJECT-TYPE The UPS voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.4 | DisplayString | read-only | mandatory |
| airFMSysCoilCfg OBJECT-TYPE The type of cooling coils installed in the Modules in this System: DX coil, DX and MultiCool (chilled water) coils, DX and Economizer coils, or only a Chilled Liquid coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.5 | INTEGER {notApplicable(1), dx(2), econ(3), multicool(4), chilledWater(5)} | read-only | mandatory |
| airFMSysRefrigType OBJECT-TYPE The type of refrigerant used by each compressor in the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.6 | INTEGER {notApplicable(1), r22(2), r407C(3)} | read-only | mandatory |
| airFMSysHeatRejection OBJECT-TYPE The method the Modules in this System use to transfer heat away from the refrigerant. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.7 | INTEGER {notApplicable(1), airCooled(2), waterCooled(3), glycolCooled(4)} | read-only | mandatory |
| airFMSysDischAirPtrn OBJECT-TYPE The discharge air pattern for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.8 | INTEGER {notApplicable(1), upFlow(2), downFlow(3), horizFlow(4)} | read-only | mandatory |
| airFMSysAirFltr OBJECT-TYPE The type of air filters (standard or high efficiency) installed in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.9 | INTEGER {notApplicable(1), standard(2), highEfficiency(3)} | read-only | mandatory |
| airFMSysFlowSwitch OBJECT-TYPE The location of the optional flow switch. None: No flow switch is installed in this System. DX: Coolant input to the heat exchanger (condenser). MultiCool: Chilled water input to the MultiCool coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.10 | INTEGER {notApplicable(1), none(2), dxEcon(3), multiCoolChillWater(4)} | read-only | mandatory |
| airFMSysCoilFluidVlvAct OBJECT-TYPE The type of valve actuator installed on the coil fluid valve. The coil fluid valve controls the flow of coolant into a fluid cooling coil, such as a MultiCool or Economizer coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.11 | INTEGER {notApplicable(1), none(2), springAnalog(3), floatingControl(4)} | read-only | mandatory |
| airFMSysCoilFluidVlvType OBJECT-TYPE The type of coil fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.12 | INTEGER {notApplicable(1), twoWay(2), threeWay(3)} | read-only | mandatory |
| airFMSysCndsrFluidVlvAct OBJECT-TYPE The type of valve actuator installed on the Condenser fluid valve. The Condenser fluid valve controls the flow of coolant into the heat exchanger (condenser) to regulate head pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.13 | INTEGER {notApplicable(1), none(2), floatingControl(3)} | read-only | mandatory |
| airFMSysCndsrFluidVlvType OBJECT-TYPE The type of Condenser fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.14 | INTEGER {notApplicable(1), twoWay(2), threeWay(3)} | read-only | mandatory |
| airFMSysHotWaterVlvAct OBJECT-TYPE The type of valve actuator installed on the hot water valve. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.3.15 | INTEGER {notApplicable(1), none(2), springAnalog(3), floatingControl(4)} | read-only | mandatory |
| airFMSysNumRemoteSensors OBJECT-TYPE The number of remote sensors detected by the system. | 1.3.6.1.4.1.318.1.1.13.1.4.3.16 | INTEGER | read-only | mandatory |
| airFMSysConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.4 | |||
| airFMSysPrimaryControlSensor OBJECT-TYPE Selects whether return or remote sensors will control the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.1 | INTEGER {notApplicable(1), return(2), remote(3)} | read-write | mandatory |
| airFMSysRemoteSensorData OBJECT-TYPE Selects whether average temperature or max temperature will be used when remote sensors are selected for control of the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.2 | INTEGER {notApplicable(1), average(2), maximum(3)} | read-write | mandatory |
| airFMSysFastStartup OBJECT-TYPE Minimizes the time for the cooling process to begin after other delay constraints have been met. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysStartupDelay OBJECT-TYPE Set the delay that begins when power is applied and ends when the System starts. This allows you to create a staged restart among your Systems after a power loss. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.4 | INTEGER | read-write | mandatory |
| airFMSysModeDelay OBJECT-TYPE Set the delay between starting the blowers and engaging the modes. It allows the sensors to read room conditions accurately and allows the controller to check for major alarms before engaging a mode. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.5 | INTEGER | read-write | mandatory |
| airFMSysCommLossShutdownDelay OBJECT-TYPE Set the delay between an Expansion Module losing communication with the Main Module and the Expansion Module shutting down. A value of -1 will keep the Expansion Module running after a communication loss. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.6 | INTEGER | read-write | mandatory |
| airFMSysResetSysFailure OBJECT-TYPE Setting this OID to reset(2) will allows the system to return from any failure condition, if the failure(s) have cleared. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.7 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMSysResetUserDflts OBJECT-TYPE Setting this OID to reset(2) will reset all system parameters that can be edited by the user to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.8 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMSysResetFldSrvcDflts OBJECT-TYPE Setting this OID to reset(2) will reset all system parameters that can only be edited by the field service engineer to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.9 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMSysResetRunHours OBJECT-TYPE Setting this OID to reset(2) will reset the system Run Hours. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.4.10 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMSysCooling OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.5 | |||
| airFMSysCompMinOnTime OBJECT-TYPE Set the minimum time the compressor continues to operate after it is started. The delay protects the compressor from damage. Caution: Reducing this delay shortens compressor life. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.1 | INTEGER | read-write | mandatory |
| airFMSysCompMinOffTime OBJECT-TYPE Set the minimum time the compressor will remain off after it ceases operation. The delay protects the compressor from damage. Caution: Reducing this delay shortens compressor life. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.2 | INTEGER | read-write | mandatory |
| airFMSysCompRotPeriod OBJECT-TYPE Set how often to perform compressor runtime balancing. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.3 | INTEGER | read-write | mandatory |
| airFMSysEconIsolVlvOpenDelay OBJECT-TYPE Set the delay between opening the Economizer Isolator output relay and engaging the compressors. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.4 | INTEGER | read-write | mandatory |
| airFMSysEconIsolVlvCloseDelay OBJECT-TYPE Set the delay between disengaging the compressor and closing the Economizer Isolator output relay. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.5 | INTEGER | read-write | mandatory |
| airFMSysCndsrFluidVlvCloseDelay OBJECT-TYPE Set the time the condenser valve remains open after the compressors disengage. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.6 | INTEGER | read-write | mandatory |
| airFMSysInterstageDelay OBJECT-TYPE The DX interstage delay allows the first compressor's cooling to take effect before engaging the second compressor. This prevents the second compressor from cycling on and off excessively. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.7 | INTEGER | read-write | mandatory |
| airFMSysCoolState OBJECT-TYPE Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysCoolEssFunction OBJECT-TYPE Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.9 | INTEGER {notApplicable(1), yes(2), no(3)} | read-write | mandatory |
| airFMSysCoolSetpointC OBJECT-TYPE The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.10 | INTEGER | read-write | mandatory |
| airFMSysCoolSetpointF OBJECT-TYPE The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.11 | INTEGER | read-write | mandatory |
| airFMSysCoolDeadbandC OBJECT-TYPE The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.12 | INTEGER | read-write | mandatory |
| airFMSysCoolDeadbandF OBJECT-TYPE The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.13 | INTEGER | read-write | mandatory |
| airFMSysCoolEconIsolFunction OBJECT-TYPE Set the Economizer Automatic Coolant Isolation valve to enabled or disabled. This valve anticipates a cooling demand and opens the coil fluid valve. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysSuctPresCompensation OBJECT-TYPE Set the Suction Pressure Compensation to enabled or disabled. This function attempts to keep the suction pressure from exceeding 95 psi. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysCoilFluidActivThreshC OBJECT-TYPE The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.16 | INTEGER | read-write | mandatory |
| airFMSysCoilFluidActivThreshF OBJECT-TYPE The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.17 | INTEGER | read-write | mandatory |
| airFMSysCoilFluidActivDeadbandC OBJECT-TYPE The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the deadband. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.18 | INTEGER | read-write | mandatory |
| airFMSysCoilFluidActivDeadbandF OBJECT-TYPE The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the deadband. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.19 | INTEGER | read-write | mandatory |
| airFMSysCoolPIDMethod OBJECT-TYPE Set the multipliers that the PID algorithm will use to calculate the cool output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.20 | INTEGER {notApplicable(1), p(2), pi(3), pid(4)} | read-write | mandatory |
| airFMSysCoolPIDGainP OBJECT-TYPE Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.21 | INTEGER | read-write | mandatory |
| airFMSysCoolPIDResetRateI OBJECT-TYPE Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.22 | INTEGER | read-write | mandatory |
| airFMSysCoolPIDDerivativeD OBJECT-TYPE Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.5.23 | INTEGER | read-write | mandatory |
| airFMSysHumidify OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.6 | |||
| airFMSysHumState OBJECT-TYPE Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.1 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysHumEssFunction OBJECT-TYPE Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.2 | INTEGER {notApplicable(1), yes(2), no(3)} | read-write | mandatory |
| airFMSysHumSetpoint OBJECT-TYPE The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH below the dehumidification setpoint. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.3 | INTEGER | read-write | mandatory |
| airFMSysHumDeadband OBJECT-TYPE The humidity range that controls output when the selected control sensor humidity is below the setpoint. At the top of this range, the humidification mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.4 | INTEGER | read-write | mandatory |
| airFMSysHumCtrlSetting OBJECT-TYPE Set the method to control the humidity in the room. The two methods are Relative Humidity (RH) or Dew Point of the selected control sensor air. The dew point method helps correct for hot spots near the selected control sensors. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.5 | INTEGER {notApplicable(1), relativeHum(2), dewPoint(3)} | read-write | mandatory |
| airFMSysActualHumCtrl OBJECT-TYPE The humidity control method the system is using. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.6 | INTEGER {notApplicable(1), relativeHum(2), dewPoint(3)} | read-only | mandatory |
| airFMSysHumSensBand OBJECT-TYPE The percentage of relative humidity below the setpoint at which the humidifier will output at 100% of capacity. Measured in percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.6.7 | INTEGER | read-write | mandatory |
| airFMSysDehumidify OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.7 | |||
| airFMSysDehumState OBJECT-TYPE Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.1 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysDehumEssFunction OBJECT-TYPE Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.2 | INTEGER {notApplicable(1), yes(2), no(3)} | read-write | mandatory |
| airFMSysDehumSetpoint OBJECT-TYPE The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH above the humidification setpoint if a humidifier is installed. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.3 | INTEGER | read-write | mandatory |
| airFMSysDehumDeadband OBJECT-TYPE The humidity range above the setpoint at which the dehumidification mode will output at 100%. The deadband does not apply to PID controlled modes. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.4 | INTEGER | read-write | mandatory |
| airFMSysDehumCapacity OBJECT-TYPE Set the dehumidification mode to use either half of the cooling coil or the full coil when dehumidifying the room. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.5 | INTEGER {notApplicable(1), half(2), full(3)} | read-write | mandatory |
| airFMSysDehumPIDMethod OBJECT-TYPE Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.6 | INTEGER {notApplicable(1), p(2), pi(3), pid(4)} | read-write | mandatory |
| airFMSysDehumPIDGainP OBJECT-TYPE Set the proportional multiplier to correct for differences between the selected control sensor actual humidity and the setpoint. Measured in %/%RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.7 | INTEGER | read-write | mandatory |
| airFMSysDehumPIDResetRateI OBJECT-TYPE Set the integral multiplier to correct for the proportional offset. Measured in %/(%RH * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.8 | INTEGER | read-write | mandatory |
| airFMSysDehumPIDDerivativeD OBJECT-TYPE Set the derivative multiplier to counteract overshoot and droop during changes in the room humidity. Measure in %/(%RH / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.7.9 | INTEGER | read-write | mandatory |
| airFMSysReheat OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.8 | |||
| airFMSysReheatState OBJECT-TYPE Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.1 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysReheatEssFunction OBJECT-TYPE Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.2 | INTEGER {notApplicable(1), yes(2), no(3)} | read-write | mandatory |
| airFMSysReheatSetpointC OBJECT-TYPE The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.3 | INTEGER | read-write | mandatory |
| airFMSysReheatSetpointF OBJECT-TYPE The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.4 | INTEGER | read-write | mandatory |
| airFMSysReheatDeadbandC OBJECT-TYPE The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.5 | INTEGER | read-write | mandatory |
| airFMSysReheatDeadbandF OBJECT-TYPE The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.6 | INTEGER | read-write | mandatory |
| airFMSysReheatPIDMethod OBJECT-TYPE Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.7 | INTEGER {notApplicable(1), p(2), pi(3), pid(4)} | read-write | mandatory |
| airFMSysReheatPIDGainP OBJECT-TYPE Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.8 | INTEGER | read-write | mandatory |
| airFMSysReheatPIDResetRateI OBJECT-TYPE Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.9 | INTEGER | read-write | mandatory |
| airFMSysReheatPIDDerivativeD OBJECT-TYPE Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.8.10 | INTEGER | read-write | mandatory |
| airFMSysThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.9 | |||
| airFMSysHighSplyTempC OBJECT-TYPE The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.1 | INTEGER | read-write | mandatory |
| airFMSysHighSplyTempF OBJECT-TYPE The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.2 | INTEGER | read-write | mandatory |
| airFMSysLowSplyTempC OBJECT-TYPE The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.3 | INTEGER | read-write | mandatory |
| airFMSysLowSplyTempF OBJECT-TYPE The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.4 | INTEGER | read-write | mandatory |
| airFMSysHighCoilFluidTempC OBJECT-TYPE The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.5 | INTEGER | read-write | mandatory |
| airFMSysHighCoilFluidTempF OBJECT-TYPE The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.6 | INTEGER | read-write | mandatory |
| airFMSysLowCoilFluidTempC OBJECT-TYPE The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.7 | INTEGER | read-write | mandatory |
| airFMSysLowCoilFluidTempF OBJECT-TYPE The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.8 | INTEGER | read-write | mandatory |
| airFMSysHighCtrlTempC OBJECT-TYPE The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.9 | INTEGER | read-write | mandatory |
| airFMSysHighCtrlTempF OBJECT-TYPE The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.10 | INTEGER | read-write | mandatory |
| airFMSysLowCtrlTempC OBJECT-TYPE The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.11 | INTEGER | read-write | mandatory |
| airFMSysLowCtrlTempF OBJECT-TYPE The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.12 | INTEGER | read-write | mandatory |
| airFMSysHighCtrlHum OBJECT-TYPE The high humidity threshold for air monitored by the System. If the humidity exceeds the threshold, an alarm will occur. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.13 | INTEGER | read-write | mandatory |
| airFMSysLowCtrlHum OBJECT-TYPE The low humidity threshold for air monitored by the System. If the humidity drops below the threshold, an alarm will occur. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.14 | INTEGER | read-write | mandatory |
| airFMSysTempAlarmDelay OBJECT-TYPE The amount of time the blower must be on before a temperature alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.15 | INTEGER | read-write | mandatory |
| airFMSysHumAlarmDelay OBJECT-TYPE The amount of time the blower must be on before a humidity alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.9.16 | INTEGER | read-write | mandatory |
| airFMSysInputs OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.10 | |||
| airFMSysInputTableSize OBJECT-TYPE The number of entries in the airFMSysInputTable. | 1.3.6.1.4.1.318.1.1.13.1.4.10.1 | INTEGER | read-only | mandatory |
| airFMSysInputTable OBJECT-TYPE Allows for getting information from each input contact. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2 | not-accessible | mandatory | |
| airFMSysInputEntry OBJECT-TYPE The input contact to obtain status from. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1 | not-accessible | mandatory | |
| airFMSysInputIndex OBJECT-TYPE The number designator of the Input Contact. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysInputName OBJECT-TYPE The configurable name for the Input Contact. Maximum text input is 13 characters. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.2 | DisplayString | read-write | mandatory |
| airFMSysInputStatus OBJECT-TYPE The state of this contact: Open or Closed. A violation will occur when this relay is not in its normal state. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.3 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airFMSysInputNormalState OBJECT-TYPE Set the normal state of this contact (the state when no alarm/event exists). | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.4 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airFMSysInputDelay OBJECT-TYPE Set the delay between this contact exiting its normal state and an alarm being triggered. Measured in seconds. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.5 | INTEGER | read-write | mandatory |
| airFMSysInputAlarmAction OBJECT-TYPE Sets the behavior for this contact when it exits its normal state. | 1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.6 | INTEGER {statusOnly(1), minor(2), major(3), remoteRunStop(4), nonessStop(5), immShutdown(6)} | read-write | mandatory |
| airFMSysOutputs OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.11 | |||
| airFMSysOutputTableSize OBJECT-TYPE The number of entries in the airFMSysOutputTable. | 1.3.6.1.4.1.318.1.1.13.1.4.11.1 | INTEGER | read-only | mandatory |
| airFMSysOutputTable OBJECT-TYPE Allows for getting information from each output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.11.2 | not-accessible | mandatory | |
| airFMSysOutputEntry OBJECT-TYPE The output relay to obtain status from. | 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1 | not-accessible | mandatory | |
| airFMSysOutputIndex OBJECT-TYPE The number designator of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysOutputStatus OBJECT-TYPE The state of this relay: Open or Closed. A violation will occur when this relay is not in its normal state. | 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.2 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airFMSysOutputNormalState OBJECT-TYPE Set the normal state of this relay (the state when no alarm/event exists). | 1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.3 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airFMSysAlarmMap OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12 | |||
| airFMSysAlarmMapSys OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12.1 | |||
| airFMSysAlarmMapSysTableSize OBJECT-TYPE The number of entries in the airFMSysAlarmMapSysTable. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapSysTable OBJECT-TYPE Allows for getting alarm map information. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2 | not-accessible | mandatory | |
| airFMSysAlarmMapSysEntry OBJECT-TYPE The system alarm map type to reference. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1 | not-accessible | mandatory | |
| airFMSysAlarmMapSysOutputIndex OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapSysAnyAlarm OBJECT-TYPE System alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.2 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSystemOn OBJECT-TYPE System alarm map setting for System On. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSystemOffline OBJECT-TYPE System alarm map setting for System Offline. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.4 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysHighEnvTemp OBJECT-TYPE System alarm map setting for High Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.5 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysLowEnvTemp OBJECT-TYPE System alarm map setting for Low Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.6 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysHighEnvHum OBJECT-TYPE System alarm map setting for High Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.7 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysLowEnvHum OBJECT-TYPE System alarm map setting for Low Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysFireDet OBJECT-TYPE System alarm map setting for Fire Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.9 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysSmokeDet OBJECT-TYPE System alarm map setting for Smoke Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.10 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysEconIsol OBJECT-TYPE System alarm map setting for Econ Isolator. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.11 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysSupplySensFail OBJECT-TYPE System alarm map setting for Supply Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.12 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysReturnSensFail OBJECT-TYPE System alarm map setting for Return Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.13 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysRemSensRemoved OBJECT-TYPE System alarm map setting for Remote Sensor Removed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysPrimSensFail OBJECT-TYPE System alarm map setting for Primary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysSecSensFail OBJECT-TYPE System alarm map setting for Secondary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.16 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapSysSecSensActive OBJECT-TYPE System alarm map setting for Secondary Sensor Active. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.17 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainMod OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12.2 | |||
| airFMSysAlarmMapMainModTableSize OBJECT-TYPE The number of entries in the airFMSysAlarmMapMainModTable. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapMainModTable OBJECT-TYPE Allows for getting alarm map information. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2 | not-accessible | mandatory | |
| airFMSysAlarmMapMainModEntry OBJECT-TYPE The main module alarm map type to reference. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1 | not-accessible | mandatory | |
| airFMSysAlarmMapMainModOutputIndex OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapMainModAnyAlarm OBJECT-TYPE Main Module alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.2 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModMaintReq OBJECT-TYPE Main Module alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModCoolFail OBJECT-TYPE Main Module alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.4 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModHighSupplyTemp OBJECT-TYPE Main Module alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.5 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModLowSupplyTemp OBJECT-TYPE Main Module alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.6 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModHumFail OBJECT-TYPE Main Module alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.7 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModHumReplCyl OBJECT-TYPE Main Module alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModCondPumpFail OBJECT-TYPE Main Module alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.9 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModBlwrCntl1Fail OBJECT-TYPE Main Module alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.10 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModBlwrCntl2Fail OBJECT-TYPE Main Module alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.11 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModHighFltrDP OBJECT-TYPE Main Module alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.12 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModLowAirFlow OBJECT-TYPE Main Module alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.13 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModAirBlckIntOpen OBJECT-TYPE Main Module alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapMainModWaterDetected OBJECT-TYPE Main Module alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12.3 | |||
| airFMSysAlarmMapExpMod1TableSize OBJECT-TYPE The number of entries in the airFMSysAlarmMapExpMod1Table. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapExpMod1Table OBJECT-TYPE Allows for getting alarm map information. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2 | not-accessible | mandatory | |
| airFMSysAlarmMapExpMod1Entry OBJECT-TYPE The expansion module 1 alarm map type to reference. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1 | not-accessible | mandatory | |
| airFMSysAlarmMapExpMod1OutputIndex OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapExpMod1AnyAlarm OBJECT-TYPE Exp Module 1 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.2 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1MaintReq OBJECT-TYPE Exp Module 1 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1CoolFail OBJECT-TYPE Exp Module 1 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.4 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1HighSupplyTemp OBJECT-TYPE Exp Module 1 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.5 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1LowSupplyTemp OBJECT-TYPE Exp Module 1 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.6 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1HumFail OBJECT-TYPE Exp Module 1 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.7 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1HumReplCyl OBJECT-TYPE Exp Module 1 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1CondPumpFail OBJECT-TYPE Exp Module 1 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.9 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1BlwrCntl1Fail OBJECT-TYPE Exp Module 1 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.10 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1BlwrCntl2Fail OBJECT-TYPE Exp Module 1 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.11 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1HighFltrDP OBJECT-TYPE Exp Module 1 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.12 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1LowAirFlow OBJECT-TYPE Exp Module 1 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.13 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1AirBlckIntOpen OBJECT-TYPE Exp Module 1 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod1WaterDetected OBJECT-TYPE Exp Module 1 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12.4 | |||
| airFMSysAlarmMapExpMod2TableSize OBJECT-TYPE The number of entries in the airFMSysAlarmMapExpMod2Table. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapExpMod2Table OBJECT-TYPE Allows for getting alarm map information. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2 | not-accessible | mandatory | |
| airFMSysAlarmMapExpMod2Entry OBJECT-TYPE The expansion module 2 alarm map type to reference. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1 | not-accessible | mandatory | |
| airFMSysAlarmMapExpMod2OutputIndex OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapExpMod2AnyAlarm OBJECT-TYPE Exp Module 2 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.2 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2MaintReq OBJECT-TYPE Exp Module 2 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2CoolFail OBJECT-TYPE Exp Module 2 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.4 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2HighSupplyTemp OBJECT-TYPE Exp Module 2 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.5 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2LowSupplyTemp OBJECT-TYPE Exp Module 2 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.6 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2HumFail OBJECT-TYPE Exp Module 2 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.7 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2HumReplCyl OBJECT-TYPE Exp Module 2 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2CondPumpFail OBJECT-TYPE Exp Module 2 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.9 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2BlwrCntl1Fail OBJECT-TYPE Exp Module 2 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.10 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2BlwrCntl2Fail OBJECT-TYPE Exp Module 2 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.11 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2HighFltrDP OBJECT-TYPE Exp Module 2 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.12 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2LowAirFlow OBJECT-TYPE Exp Module 2 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.13 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2AirBlckIntOpen OBJECT-TYPE Exp Module 2 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapExpMod2WaterDetected OBJECT-TYPE Exp Module 2 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12.5 | |||
| airFMSysAlarmMapInputTableSize OBJECT-TYPE The number of entries in the airFMSysAlarmMapInputTable. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapInputTable OBJECT-TYPE Allows for getting alarm map information. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2 | not-accessible | mandatory | |
| airFMSysAlarmMapInputEntry OBJECT-TYPE The input contact alarm map type to reference. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1 | not-accessible | mandatory | |
| airFMSysAlarmMapInputOutputIndex OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapInput1 OBJECT-TYPE Input contact 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.2 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput2 OBJECT-TYPE Input contact 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput3 OBJECT-TYPE Input contact 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.4 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput4 OBJECT-TYPE Input contact 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.5 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput5 OBJECT-TYPE Input contact 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.6 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput6 OBJECT-TYPE Input contact 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.7 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput7 OBJECT-TYPE Input contact 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput8 OBJECT-TYPE Input contact 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.9 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput9 OBJECT-TYPE Input contact 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.10 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput10 OBJECT-TYPE Input contact 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.11 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput11 OBJECT-TYPE Input contact 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.12 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput12 OBJECT-TYPE Input contact 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.13 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput13 OBJECT-TYPE Input contact 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput14 OBJECT-TYPE Input contact 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput15 OBJECT-TYPE Input contact 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.16 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapInput16 OBJECT-TYPE Input contact 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.17 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.4.12.6 | |||
| airFMSysAlarmMapOutputTableSize OBJECT-TYPE The number of entries in the airFMSysAlarmMapOutputTable. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapOutputTable OBJECT-TYPE Allows for getting alarm map information. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2 | not-accessible | mandatory | |
| airFMSysAlarmMapOutputEntry OBJECT-TYPE The input contact alarm map type to reference. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1 | not-accessible | mandatory | |
| airFMSysAlarmMapOutputIndex OBJECT-TYPE The index of the output relay. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.1 | INTEGER | read-only | mandatory |
| airFMSysAlarmMapOutput1 OBJECT-TYPE Output relay 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.2 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput2 OBJECT-TYPE Output relay 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.3 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput3 OBJECT-TYPE Output relay 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.4 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput4 OBJECT-TYPE Output relay 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.5 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput5 OBJECT-TYPE Output relay 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.6 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput6 OBJECT-TYPE Output relay 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.7 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput7 OBJECT-TYPE Output relay 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.8 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput8 OBJECT-TYPE Output relay 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.9 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput9 OBJECT-TYPE Output relay 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.10 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput10 OBJECT-TYPE Output relay 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.11 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput11 OBJECT-TYPE Output relay 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.12 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput12 OBJECT-TYPE Output relay 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.13 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput13 OBJECT-TYPE Output relay 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.14 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput14 OBJECT-TYPE Output relay 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.15 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput15 OBJECT-TYPE Output relay 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.16 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMSysAlarmMapOutput16 OBJECT-TYPE Output relay 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.17 | INTEGER {notApplicable(1), disabled(2), enabled(3)} | read-write | mandatory |
| airFMModule OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5 | |||
| airFMModIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.1 | |||
| airFMModIdentTableSize OBJECT-TYPE The number of entries in the airFMModIdentTable. | 1.3.6.1.4.1.318.1.1.13.1.5.1.1 | INTEGER | read-only | mandatory |
| airFMModIdentTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2 | not-accessible | mandatory | |
| airFMModIdentEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1 | not-accessible | mandatory | |
| airFMModIdentModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.1 | INTEGER | read-only | mandatory |
| airFMModModelNumber OBJECT-TYPE Model number of the Module. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.2 | DisplayString | read-only | mandatory |
| airFMModSerialNumber OBJECT-TYPE Unique identification number for this Module. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.3 | DisplayString | read-only | mandatory |
| airFMModManufactureDate OBJECT-TYPE Date the Module was manufactured. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.4 | DisplayString | read-only | mandatory |
| airFMModFirmwareRev OBJECT-TYPE Revision number of the firmware installed on this Module. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.5 | DisplayString | read-only | mandatory |
| airFMModHardwareRev OBJECT-TYPE Revision number of the hardware installed on this Module. | 1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.6 | DisplayString | read-only | mandatory |
| airFMModStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.2 | |||
| airFMModStatusTableSize OBJECT-TYPE The number of entries in the airFMModStatusTable. | 1.3.6.1.4.1.318.1.1.13.1.5.2.1 | INTEGER | read-only | mandatory |
| airFMModStatusTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2 | not-accessible | mandatory | |
| airFMModStatusEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1 | not-accessible | mandatory | |
| airFMModStatusModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.1 | INTEGER | read-only | mandatory |
| airFMModSupplyTempC OBJECT-TYPE The temperature measured at the supply sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.2 | INTEGER | read-only | mandatory |
| airFMModSupplyTempF OBJECT-TYPE The temperature measured at the supply sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.3 | INTEGER | read-only | mandatory |
| airFMModSupplyHum OBJECT-TYPE The humidity measured at the supply sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.4 | INTEGER | read-only | mandatory |
| airFMModReturnTempC OBJECT-TYPE The temperature measured at the return sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.5 | INTEGER | read-only | mandatory |
| airFMModReturnTempF OBJECT-TYPE The temperature measured at the return sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.6 | INTEGER | read-only | mandatory |
| airFMModReturnHum OBJECT-TYPE The humidity measured at the return sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.7 | INTEGER | read-only | mandatory |
| airFMModFilterDiffPresPa OBJECT-TYPE The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.8 | INTEGER | read-only | mandatory |
| airFMModFilterDiffPresInWC OBJECT-TYPE The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.9 | INTEGER | read-only | mandatory |
| airFMModCoilDiffPresPa OBJECT-TYPE The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.10 | INTEGER | read-only | mandatory |
| airFMModCoilDiffPresInWC OBJECT-TYPE The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.11 | INTEGER | read-only | mandatory |
| airFMModProperties OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.3 | |||
| airFMModPropTableSize OBJECT-TYPE The number of entries in the airFMModPropTable. | 1.3.6.1.4.1.318.1.1.13.1.5.3.1 | INTEGER | read-only | mandatory |
| airFMModPropTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2 | not-accessible | mandatory | |
| airFMModPropEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1 | not-accessible | mandatory | |
| airFMModPropModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1 | INTEGER | read-only | mandatory |
| airFMModOutputCapacity OBJECT-TYPE The cooling capacity (in Kilowatts) of the displayed Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.2 | INTEGER {notApplicable(1), kw45(2), kw35(3), kw40(4), kw50(5), kw80(6)} | read-only | mandatory |
| airFMModCapacityCtrl OBJECT-TYPE The method used to load and unload the compressors. Tandem compressor Modules use two stages (one compressor each). Single compressor Modules use hot gas bypass. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.3 | INTEGER {notApplicable(1), tandem(2), hotGasBypass(3)} | read-only | mandatory |
| airFMModHeaterType OBJECT-TYPE The type of reheating device installed in this Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.4 | INTEGER {notApplicable(1), none(2), electricSCR(3), steam(4), hotWaterOnOff(5), hotGasReheat(6), hotGasAndElectric(7), hotWaterProp(8)} | read-only | mandatory |
| airFMModElectricHeaterType OBJECT-TYPE The type/capacity of the electric heater, if installed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.5 | INTEGER {notApplicable(1), kw10(2), kw15(3)} | read-only | mandatory |
| airFMModHumidifierType OBJECT-TYPE The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.6 | INTEGER {notApplicable(1), none(2), steamElectrode(3), liveSteam(4)} | read-only | mandatory |
| airFMModBlwrFreqSetting OBJECT-TYPE Frequency of the blower in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.7 | INTEGER | read-only | mandatory |
| airFMModNomCoilDiffPresPa OBJECT-TYPE The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.8 | INTEGER | read-only | mandatory |
| airFMModNomCoilDiffPresInWC OBJECT-TYPE The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.9 | INTEGER | read-only | mandatory |
| airFMModCondPump OBJECT-TYPE Indicates the presence of a condensate pump in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.10 | INTEGER {notApplicable(1), notPresent(2), present(3)} | read-only | mandatory |
| airFMModFireDetector OBJECT-TYPE Indicates the presence of a fire detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.11 | INTEGER {notApplicable(1), notPresent(2), present(3)} | read-only | mandatory |
| airFMModSmokeDetector OBJECT-TYPE Indicates the presence of a smoke detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.12 | INTEGER {notApplicable(1), notPresent(2), present(3)} | read-only | mandatory |
| airFMModWaterDetector OBJECT-TYPE Indicates the presence of a water leak detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.13 | INTEGER {notApplicable(1), notPresent(2), present(3)} | read-only | mandatory |
| airFMModCooling OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.4 | |||
| airFMModCoolTableSize OBJECT-TYPE The number of entries in the airFMModCoolTable. | 1.3.6.1.4.1.318.1.1.13.1.5.4.1 | INTEGER | read-only | mandatory |
| airFMModCoolTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2 | not-accessible | mandatory | |
| airFMModCoolEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1 | not-accessible | mandatory | |
| airFMModCoolModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.1 | INTEGER | read-only | mandatory |
| airFMModComp1 OBJECT-TYPE The status of compressor 1 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.2 | INTEGER {notApplicable(1), on(2), off(3)} | read-only | mandatory |
| airFMModComp2 OBJECT-TYPE The status of compressor 2 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.3 | INTEGER {notApplicable(1), on(2), off(3)} | read-only | mandatory |
| airFMModSuctPresKPa OBJECT-TYPE The refrigerant pressure measured at the suction inlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.4 | INTEGER | read-only | mandatory |
| airFMModSuctPresPSI OBJECT-TYPE The refrigerant pressure measured at the suction inlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.5 | INTEGER | read-only | mandatory |
| airFMModDischPresKPa OBJECT-TYPE The refrigerant pressure measured at the discharge outlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.6 | INTEGER | read-only | mandatory |
| airFMModDischPresPSI OBJECT-TYPE The refrigerant pressure measured at the discharge outlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.7 | INTEGER | read-only | mandatory |
| airFMModCondFluidVlvPos OBJECT-TYPE The position of the condenser fluid valve. The valve regulates the flow of liquid coolant into the heat exchanger (condenser). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.8 | INTEGER | read-only | mandatory |
| airFMModCoilFluidVlvPos OBJECT-TYPE The position of the coil fluid valve. The valve regulates the flow of liquid coolant in the fluid cooling coil (MultiCool, Economizer, or Chilled Water). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.9 | INTEGER | read-only | mandatory |
| airFMModHumidity OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.5 | |||
| airFMModHumTableSize OBJECT-TYPE The number of entries in the airFMModHumTable. | 1.3.6.1.4.1.318.1.1.13.1.5.5.1 | INTEGER | read-only | mandatory |
| airFMModHumTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2 | not-accessible | mandatory | |
| airFMModHumEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1 | not-accessible | mandatory | |
| airFMModHumModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.1 | INTEGER | read-only | mandatory |
| airFMModHumidifier OBJECT-TYPE The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.2 | INTEGER {notApplicable(1), none(2), steamElectrode(3), liveSteam(4)} | read-only | mandatory |
| airFMModElectrodeCurrent OBJECT-TYPE The current drawn by the electrodes of the steam cylinder humidifier. Measured in tenths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.3 | INTEGER | read-only | mandatory |
| airFMModHumActualOutput OBJECT-TYPE The humidification output of an individual Module. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.4 | INTEGER | read-only | mandatory |
| airFMModWaterConductivity OBJECT-TYPE The conductivity of the water in the humidifier cylinder. Measured in microSiemens per centimeter. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.5 | INTEGER | read-only | mandatory |
| airFMModHotWaterVlvPos OBJECT-TYPE The position of the hot water valve. 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.6 | INTEGER | read-only | mandatory |
| airFMModStmElectHumMode OBJECT-TYPE Set the humidifier function mode. Off: Remove power from electrodes. Auto: Humidifier controlled by Module controller. Drain: Remove power from electrodes and drain the cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.7 | INTEGER {notApplicable(1), off(2), auto(3), drain(4)} | read-write | mandatory |
| airFMModBlower1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.6 | |||
| airFMModBlwr1TableSize OBJECT-TYPE The number of entries in the airFMModBlwr1Table. | 1.3.6.1.4.1.318.1.1.13.1.5.6.1 | INTEGER | read-only | mandatory |
| airFMModBlwr1Table OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2 | not-accessible | mandatory | |
| airFMModBlwr1Entry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1 | not-accessible | mandatory | |
| airFMModBlwr1ModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.1 | INTEGER | read-only | mandatory |
| airFMModBlwr1CtrlType OBJECT-TYPE The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.2 | INTEGER {notApplicable(1), fujiVFD(2), ecController(3), danfossVFD(4)} | read-only | mandatory |
| airFMModBlwr1CmdFreq OBJECT-TYPE The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.3 | INTEGER | read-only | mandatory |
| airFMModBlwr1ActFreq OBJECT-TYPE The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.4 | INTEGER | read-only | mandatory |
| airFMModBlwr1Poles OBJECT-TYPE The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.5 | INTEGER | read-only | mandatory |
| airFMModBlwr1RatedHorsePower OBJECT-TYPE The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.6 | INTEGER | read-only | mandatory |
| airFMModBlwr1RatedCurrent OBJECT-TYPE The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.7 | INTEGER | read-only | mandatory |
| airFMModBlwr1ActTorq OBJECT-TYPE The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.8 | INTEGER | read-only | mandatory |
| airFMModBlwr1Current OBJECT-TYPE The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.9 | INTEGER | read-only | mandatory |
| airFMModBlwr1Vlt OBJECT-TYPE The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.10 | INTEGER | read-only | mandatory |
| airFMModBlwr1DCLinkVlt OBJECT-TYPE The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.11 | INTEGER | read-only | mandatory |
| airFMModBlwr1AccTime OBJECT-TYPE The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.12 | INTEGER | read-only | mandatory |
| airFMModBlwr1DecTime OBJECT-TYPE The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.13 | INTEGER | read-only | mandatory |
| airFMModBlwr1CapLife OBJECT-TYPE The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.14 | INTEGER | read-only | mandatory |
| airFMModBlwr1CtrlCoolFanLife OBJECT-TYPE The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.15 | INTEGER | read-only | mandatory |
| airFMModBlwr1ElOvMode OBJECT-TYPE Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.16 | INTEGER {notApplicable(1), inactive(2), active(3)} | read-only | mandatory |
| airFMModBlwr1ElOvSetting OBJECT-TYPE The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.17 | INTEGER | read-only | mandatory |
| airFMModBlwr1ElOvTimeConst OBJECT-TYPE The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.18 | INTEGER | read-only | mandatory |
| airFMModBlwr1FanPower OBJECT-TYPE The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.19 | INTEGER | read-only | mandatory |
| airFMModBlwr1HeatsinkTempC OBJECT-TYPE The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.20 | INTEGER | read-only | mandatory |
| airFMModBlwr1HeatsinkTempF OBJECT-TYPE The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.21 | INTEGER | read-only | mandatory |
| airFMModBlwr1ChokeTempC OBJECT-TYPE The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.22 | INTEGER | read-only | mandatory |
| airFMModBlwr1ChokeTempF OBJECT-TYPE The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.23 | INTEGER | read-only | mandatory |
| airFMModBlwr1InverterTempC OBJECT-TYPE The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.24 | INTEGER | read-only | mandatory |
| airFMModBlwr1InverterTempF OBJECT-TYPE The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.25 | INTEGER | read-only | mandatory |
| airFMModBlower2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.7 | |||
| airFMModBlwr2TableSize OBJECT-TYPE The number of entries in the airFMModBlwr2Table. | 1.3.6.1.4.1.318.1.1.13.1.5.7.1 | INTEGER | read-only | mandatory |
| airFMModBlwr2Table OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2 | not-accessible | mandatory | |
| airFMModBlwr2Entry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1 | not-accessible | mandatory | |
| airFMModBlwr2ModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.1 | INTEGER | read-only | mandatory |
| airFMModBlwr2CtrlType OBJECT-TYPE The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.2 | INTEGER {notApplicable(1), fujiVFD(2), ecController(3), danfossVFD(4)} | read-only | mandatory |
| airFMModBlwr2CmdFreq OBJECT-TYPE The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.3 | INTEGER | read-only | mandatory |
| airFMModBlwr2ActFreq OBJECT-TYPE The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.4 | INTEGER | read-only | mandatory |
| airFMModBlwr2Poles OBJECT-TYPE The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.5 | INTEGER | read-only | mandatory |
| airFMModBlwr2RatedHorsePower OBJECT-TYPE The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.6 | INTEGER | read-only | mandatory |
| airFMModBlwr2RatedCurrent OBJECT-TYPE The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.7 | INTEGER | read-only | mandatory |
| airFMModBlwr2ActTorq OBJECT-TYPE The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.8 | INTEGER | read-only | mandatory |
| airFMModBlwr2Current OBJECT-TYPE The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.9 | INTEGER | read-only | mandatory |
| airFMModBlwr2Vlt OBJECT-TYPE The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.10 | INTEGER | read-only | mandatory |
| airFMModBlwr2DCLinkVlt OBJECT-TYPE The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.11 | INTEGER | read-only | mandatory |
| airFMModBlwr2AccTime OBJECT-TYPE The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.12 | INTEGER | read-only | mandatory |
| airFMModBlwr2DecTime OBJECT-TYPE The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.13 | INTEGER | read-only | mandatory |
| airFMModBlwr2CapLife OBJECT-TYPE The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.14 | INTEGER | read-only | mandatory |
| airFMModBlwr2CtrlCoolFanLife OBJECT-TYPE The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.15 | INTEGER | read-only | mandatory |
| airFMModBlwr2ElOvMode OBJECT-TYPE Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.16 | INTEGER {notApplicable(1), inactive(2), active(3)} | read-only | mandatory |
| airFMModBlwr2ElOvSetting OBJECT-TYPE The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.17 | INTEGER | read-only | mandatory |
| airFMModBlwr2ElOvTimeConst OBJECT-TYPE The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.18 | INTEGER | read-only | mandatory |
| airFMModBlwr2FanPower OBJECT-TYPE The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.19 | INTEGER | read-only | mandatory |
| airFMModBlwr2HeatsinkTempC OBJECT-TYPE The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.20 | INTEGER | read-only | mandatory |
| airFMModBlwr2HeatsinkTempF OBJECT-TYPE The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.21 | INTEGER | read-only | mandatory |
| airFMModBlwr2ChokeTempC OBJECT-TYPE The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.22 | INTEGER | read-only | mandatory |
| airFMModBlwr2ChokeTempF OBJECT-TYPE The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.23 | INTEGER | read-only | mandatory |
| airFMModBlwr2InverterTempC OBJECT-TYPE The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.24 | INTEGER | read-only | mandatory |
| airFMModBlwr2InverterTempF OBJECT-TYPE The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.25 | INTEGER | read-only | mandatory |
| airFMModRunHours OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.8 | |||
| airFMModRHTableSize OBJECT-TYPE The number of entries in the airFMModRHTable. | 1.3.6.1.4.1.318.1.1.13.1.5.8.1 | INTEGER | read-only | mandatory |
| airFMModRHTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2 | not-accessible | mandatory | |
| airFMModRHEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1 | not-accessible | mandatory | |
| airFMModRHModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.1 | INTEGER | read-only | mandatory |
| airFMModRHComp1 OBJECT-TYPE Compressor 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.2 | INTEGER | read-only | mandatory |
| airFMModRHComp2 OBJECT-TYPE Compressor 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.3 | INTEGER | read-only | mandatory |
| airFMModRHHeater OBJECT-TYPE Heater run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.4 | INTEGER | read-only | mandatory |
| airFMModRHHum OBJECT-TYPE Humidifier run hours A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.5 | INTEGER | read-only | mandatory |
| airFMModRHBlwr1 OBJECT-TYPE Blower 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.6 | INTEGER | read-only | mandatory |
| airFMModRHBlwr2 OBJECT-TYPE Blower 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.7 | INTEGER | read-only | mandatory |
| airFMModRHBlwrCtrl1 OBJECT-TYPE Blower Controller 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.8 | INTEGER | read-only | mandatory |
| airFMModRHBlwrCtrl2 OBJECT-TYPE Blower Controller 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.9 | INTEGER | read-only | mandatory |
| airFMModRHComp1Reset OBJECT-TYPE Reset the compressor 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.10 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModRHComp2Reset OBJECT-TYPE Reset the compressor 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.11 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModRHHeaterReset OBJECT-TYPE Reset the heater run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.12 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModRHHumReset OBJECT-TYPE Reset the humidifier run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.13 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModRHBlwr1Reset OBJECT-TYPE Reset the blower 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.14 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModRHBlwr2Reset OBJECT-TYPE Reset the blower 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.15 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntervals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.9 | |||
| airFMModServIntComp1 OBJECT-TYPE The interval at which to generate a maintenance alarm for compressor 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.1 | INTEGER | read-write | mandatory |
| airFMModServIntComp2 OBJECT-TYPE The interval at which to generate a maintenance alarm for compressor 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.2 | INTEGER | read-write | mandatory |
| airFMModServIntHeater OBJECT-TYPE The interval at which to generate a maintenance alarm for the reheat components. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.3 | INTEGER | read-write | mandatory |
| airFMModServIntHum OBJECT-TYPE The interval at which to generate a maintenance alarm for the humidifier. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.4 | INTEGER | read-write | mandatory |
| airFMModServIntBlwr1 OBJECT-TYPE The interval at which to generate a maintenance alarm for blower 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.5 | INTEGER | read-write | mandatory |
| airFMModServIntBlwr2 OBJECT-TYPE The interval at which to generate a maintenance alarm for blower 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.6 | INTEGER | read-write | mandatory |
| airFMModServIntBlwrCtrl1 OBJECT-TYPE The interval at which to generate a maintenance alarm for blower controller 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.7 | INTEGER | read-write | mandatory |
| airFMModServIntBlwrCtrl2 OBJECT-TYPE The interval at which to generate a maintenance alarm for blower controller 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.9.8 | INTEGER | read-write | mandatory |
| airFMModServIntResets OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.5.10 | |||
| airFMModServIntResetTableSize OBJECT-TYPE The number of entries in the airFMModServIntTable. | 1.3.6.1.4.1.318.1.1.13.1.5.10.1 | INTEGER | read-only | mandatory |
| airFMModServIntResetTable OBJECT-TYPE Allows for getting information from each module in the system. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2 | not-accessible | mandatory | |
| airFMModServIntResetEntry OBJECT-TYPE The module to get information from. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1 | not-accessible | mandatory | |
| airFMModServIntResetModuleIndex OBJECT-TYPE The index of the module. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1 | INTEGER | read-only | mandatory |
| airFMModServIntComp1Reset OBJECT-TYPE Reset the compressor 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.2 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntComp2Reset OBJECT-TYPE Reset the compressor 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.3 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntHeaterReset OBJECT-TYPE Reset the heater service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.4 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntHumReset OBJECT-TYPE Reset the humidifier service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.5 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntBlwr1Reset OBJECT-TYPE Reset the blower 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.6 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntBlwr2Reset OBJECT-TYPE Reset the blower 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.7 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntBlwrCtrl1Reset OBJECT-TYPE Reset the blower controller 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.8 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMModServIntBlwrCtrl2Reset OBJECT-TYPE Reset the blower controller 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. | 1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.9 | INTEGER {notApplicable(1), noOperation(2), reset(3)} | read-write | mandatory |
| airFMAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.1.6 | |||
| airFMAlarmClearActiveGroupAlarms OBJECT-TYPE Clear active group alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and return the noOperation value. | 1.3.6.1.4.1.318.1.1.13.1.6.1 | INTEGER {noOperation(1), clearAlarms(2)} | read-write | mandatory |
| airFMAlarmClearActiveSysModAlarms OBJECT-TYPE Clear active system and module alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and return the noOperation value. | 1.3.6.1.4.1.318.1.1.13.1.6.2 | INTEGER {noOperation(1), clearAlarms(2)} | read-write | mandatory |
| airFMAlarmConditionsTableSize OBJECT-TYPE The number of active alarm conditions in the airFMAlarmConditionTable. | 1.3.6.1.4.1.318.1.1.13.1.6.3 | INTEGER | read-only | mandatory |
| airFMAlarmConditionsTable OBJECT-TYPE Table of active alarm conditions for the device. | 1.3.6.1.4.1.318.1.1.13.1.6.4 | not-accessible | mandatory | |
| airFMAlarmConditionsEntry OBJECT-TYPE Alarm condition specification | 1.3.6.1.4.1.318.1.1.13.1.6.4.1 | not-accessible | mandatory | |
| airFMAlarmConditionsIndex OBJECT-TYPE Alarm condition index. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.1 | INTEGER | read-only | mandatory |
| airFMAlarmSeverity OBJECT-TYPE Severity of the alarm. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.2 | INTEGER {informational(1), warningMinor(2), criticalMajor(3)} | read-only | mandatory |
| airFMAlarmType OBJECT-TYPE Type of alarm. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.3 | INTEGER {group(1), system(2), mainMod(3), expMod1(4), expMod2(5)} | read-only | mandatory |
| airFMEventCode OBJECT-TYPE APC event code for the alarm. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.4 | INTEGER | read-only | mandatory |
| airFMAlarmDate OBJECT-TYPE Date the alarm was recorded. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.5 | DisplayString | read-only | mandatory |
| airFMAlarmTime OBJECT-TYPE Time the alarm was recorded. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.6 | DisplayString | read-only | mandatory |
| airFMAlarmDescription OBJECT-TYPE Description of the alarm. | 1.3.6.1.4.1.318.1.1.13.1.6.4.1.7 | DisplayString (SIZE(0..64)) | read-only | mandatory |
| airPA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.2 | |||
| airPAIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.2.1 | |||
| airPAIdentName OBJECT-TYPE A character string identifying the device name. | 1.3.6.1.4.1.318.1.1.13.2.1.1 | DisplayString | read-only | mandatory |
| airPAModelNumber OBJECT-TYPE A character string identifying the device model number. | 1.3.6.1.4.1.318.1.1.13.2.1.2 | DisplayString | read-only | mandatory |
| airPADateOfManufacture OBJECT-TYPE A character string identifying when the device was produced. | 1.3.6.1.4.1.318.1.1.13.2.1.3 | DisplayString | read-only | mandatory |
| airPASerialNumber OBJECT-TYPE A character string identifying the device serial number. | 1.3.6.1.4.1.318.1.1.13.2.1.4 | DisplayString | read-only | mandatory |
| airPAFirmwareRevision OBJECT-TYPE A character string identifying the device firmware revision. | 1.3.6.1.4.1.318.1.1.13.2.1.5 | DisplayString | read-only | mandatory |
| airPAHardwareRevision OBJECT-TYPE A character string identifying the device hardware revision. | 1.3.6.1.4.1.318.1.1.13.2.1.6 | DisplayString | read-only | mandatory |
| airPAStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.2.2 | |||
| airPASystemPower OBJECT-TYPE The status of the unit's system power setting. ON(1) The system power is turned on. OFF(2) The system power is turned off. | 1.3.6.1.4.1.318.1.1.13.2.2.1 | INTEGER {powerON(1), powerOFF(2)} | read-only | mandatory |
| airPAOperatingMode OBJECT-TYPE The current operating mode of the unit. OFF(1) The system is off. VENTING(2) The system's venting function is active. COOLING(3) The system's cooling function is active. | 1.3.6.1.4.1.318.1.1.13.2.2.2 | INTEGER {modeOFF(1), modeVENTING(2), modeCOOLING(3)} | read-only | mandatory |
| airPASetpointTempF OBJECT-TYPE The temperature setpoint in Fahrenheit to which the unit is controlling. | 1.3.6.1.4.1.318.1.1.13.2.2.3 | INTEGER | read-only | mandatory |
| airPASetpointTempC OBJECT-TYPE The temperature setpoint in Celsius to which the unity is controlling. | 1.3.6.1.4.1.318.1.1.13.2.2.4 | INTEGER | read-only | mandatory |
| airPABlowerSpeed OBJECT-TYPE The unit's blower speed setting. LOW(1) The blower speed is low. HIGH(2) The blower speed is high. | 1.3.6.1.4.1.318.1.1.13.2.2.5 | INTEGER {speedLOW(1), speedHIGH(2)} | read-only | mandatory |
| airPACompressor OBJECT-TYPE The unit's compressor status. ON(1) The compressor is turned on. OFF(2) The compressor is turned off. | 1.3.6.1.4.1.318.1.1.13.2.2.6 | INTEGER {statusON(1), statusOFF(2)} | read-only | mandatory |
| airPACondenserFan OBJECT-TYPE The unit's condenser fan status. ON(1) The condenser fan is turned on. OFF(2) The condenser fan is turned off. | 1.3.6.1.4.1.318.1.1.13.2.2.7 | INTEGER {statusON(1), statusOFF(2)} | read-only | mandatory |
| airPACondensatePump OBJECT-TYPE The unit's condensate pump status. ON(1) The condensate pump is turned on. OFF(2) The condensate pump is turned off. | 1.3.6.1.4.1.318.1.1.13.2.2.8 | INTEGER {statusON(1), statusOFF(2)} | read-only | mandatory |
| airPASupplyTempF OBJECT-TYPE The supply temperature in degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.2.2.9 | INTEGER | read-only | mandatory |
| airPASupplyTempC OBJECT-TYPE The supply temperature in degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.2.2.10 | INTEGER | read-only | mandatory |
| airPAReturnTempF OBJECT-TYPE The return temperature in degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.2.2.11 | INTEGER | read-only | mandatory |
| airPAReturnTempC OBJECT-TYPE The return temperature in degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.2.2.12 | INTEGER | read-only | mandatory |
| airPARemoteTempF OBJECT-TYPE The remote temperature in degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.2.2.13 | INTEGER | read-only | mandatory |
| airPARemoteTempC OBJECT-TYPE The remote temperature in degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.2.2.14 | INTEGER | read-only | mandatory |
| airPARemoteHumidity OBJECT-TYPE The remote humidity. | 1.3.6.1.4.1.318.1.1.13.2.2.15 | INTEGER | read-only | mandatory |
| airIR OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3 | |||
| airIRAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.1 | |||
| airIRAlarmConditionsTableSize OBJECT-TYPE The number of active alarm conditions in the airIRAlarmConditionTable. | 1.3.6.1.4.1.318.1.1.13.3.1.1 | INTEGER | read-only | mandatory |
| airIRAlarmConditionsTable OBJECT-TYPE Table of active alarm conditions for the device. | 1.3.6.1.4.1.318.1.1.13.3.1.2 | not-accessible | mandatory | |
| airIRAlarmConditionsEntry OBJECT-TYPE Alarm condition specification | 1.3.6.1.4.1.318.1.1.13.3.1.2.1 | not-accessible | mandatory | |
| airIRAlarmConditionsIndex OBJECT-TYPE Alarm condition index. | 1.3.6.1.4.1.318.1.1.13.3.1.2.1.1 | INTEGER | read-only | mandatory |
| airIREventCode OBJECT-TYPE Code for the alarm. | 1.3.6.1.4.1.318.1.1.13.3.1.2.1.2 | INTEGER | read-only | mandatory |
| airIRAlarmDescription OBJECT-TYPE Description of the alarm. | 1.3.6.1.4.1.318.1.1.13.3.1.2.1.3 | DisplayString (SIZE(0..64)) | read-only | mandatory |
| airIRRC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2 | |||
| airIRRCGroup OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.1 | |||
| airIRRCGroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.1.1 | |||
| airIRRCGroupStatusCoolOutput OBJECT-TYPE Group coolant output in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.1 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusCoolDemand OBJECT-TYPE Group coolant demand in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.2 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusAirFlowUS OBJECT-TYPE Group air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.3 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusAirFlowMetric OBJECT-TYPE Group air flow in liters per second. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.4 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusMaxRackInletTempUS OBJECT-TYPE Group maximum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.5 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusMaxRackInletTempMetric OBJECT-TYPE Group maximum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.6 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusMinRackInletTempUS OBJECT-TYPE Group minimum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.7 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusMinRackInletTempMetric OBJECT-TYPE Group minimum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.8 | INTEGER | read-only | mandatory |
| airIRRCGroupStatusActiveFlowControlStatus OBJECT-TYPE Status of the active flow control system. | 1.3.6.1.4.1.318.1.1.13.3.2.1.1.9 | INTEGER {under(1), okay(2), over(3), notApplicable(4)} | read-only | mandatory |
| airIRRCGroupSetpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.1.2 | |||
| airIRRCGroupSetpointsCoolUS OBJECT-TYPE Group cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.1 | INTEGER | read-write | mandatory |
| airIRRCGroupSetpointsCoolMetric OBJECT-TYPE Group cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.2 | INTEGER | read-write | mandatory |
| airIRRCGroupSetpointsSupplyAirUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.3 | INTEGER | read-write | mandatory |
| airIRRCGroupSetpointsSupplyAirMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.4 | INTEGER | read-write | mandatory |
| airIRRCGroupSetpointsFanSpeedPreference OBJECT-TYPE The preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.5 | INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)} | read-write | mandatory |
| airIRRCGroupSetpointsFanSpeedControl OBJECT-TYPE The fan speed control setting. Automatic(1) - controller manages fan speed. Manual(2) - fan speed is fixed and set by the fan speed preference. See airIRRCGroupSetpointsFanSpeedPreference. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.6 | INTEGER {automatic(1), manual(2)} | read-write | mandatory |
| airIRRCGroupSetpointsActiveFlowControlBias OBJECT-TYPE The active flow control bias setting. | 1.3.6.1.4.1.318.1.1.13.3.2.1.2.7 | INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)} | read-write | mandatory |
| airIRRCGroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.1.3 | |||
| airIRRCGroupConfigNumberofCoolingUnits OBJECT-TYPE The number of cooling units present in the group. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.1 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigConfigurationType OBJECT-TYPE The group configuration type. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.2 | INTEGER {racs(1), hacs(2), in-row(3), cacs(4)} | read-write | mandatory |
| airIRRCGroupConfigPctGlycol OBJECT-TYPE The glycol mixture in percent. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.3 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigCoolGainP OBJECT-TYPE The gain component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.4 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigCoolResetRateI OBJECT-TYPE The integral component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.5 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigCoolDerivativeD OBJECT-TYPE The derivative component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.6 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigMaxFanSpeed OBJECT-TYPE The maximum desired fan speed setting in percent. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.7 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigNumberOfActiveFlowControllers OBJECT-TYPE The number of active flow controllers present in the group. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.8 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigActiveFlowControllerLampTest OBJECT-TYPE Turns off/on the active flow controller lamp test. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.9 | INTEGER {off(1), on(2)} | read-write | mandatory |
| airIRRCGroupConfigAltitudeUS OBJECT-TYPE The group altitude of the units above sea level in feet. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.10 | INTEGER | read-write | mandatory |
| airIRRCGroupConfigAltitudeMetric OBJECT-TYPE The group altitude of the units above sea level in meters. | 1.3.6.1.4.1.318.1.1.13.3.2.1.3.11 | INTEGER | read-write | mandatory |
| airIRRCUnit OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2 | |||
| airIRRCUnitIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2.1 | |||
| airIRRCUnitIdentID OBJECT-TYPE The unit identification number. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.1 | INTEGER | read-write | mandatory |
| airIRRCUnitIdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.2 | DisplayString | read-write | mandatory |
| airIRRCUnitIdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.3 | DisplayString | read-write | mandatory |
| airIRRCUnitIdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.4 | DisplayString | read-only | mandatory |
| airIRRCUnitIdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.5 | DisplayString | read-only | mandatory |
| airIRRCUnitIdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.6 | DisplayString | read-only | mandatory |
| airIRRCUnitIdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.7 | DisplayString | read-only | mandatory |
| airIRRCUnitIdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.3.2.2.1.8 | DisplayString | read-only | mandatory |
| airIRRCUnitStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2.2 | |||
| airIRRCUnitStatusOperateMode OBJECT-TYPE The cooling unit operating mode. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.1 | INTEGER {standby(1), on(2), idle(3)} | read-only | mandatory |
| airIRRCUnitStatusCoolOutput OBJECT-TYPE The unit cooling output in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.2 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusCoolDemand OBJECT-TYPE The unit cooling demand in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.3 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusAirFlowUS OBJECT-TYPE The unit air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.4 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusAirFlowMetric OBJECT-TYPE The unit air flow in hundredths of liters per second. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.5 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusRackInletTempUS OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.6 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusRackInletTempMetric OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.7 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusSupplyAirTempUS OBJECT-TYPE The unit supply air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.8 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusSupplyAirTempMetric OBJECT-TYPE The unit supply air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.9 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusReturnAirTempUS OBJECT-TYPE The unit return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.10 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusReturnAirTempMetric OBJECT-TYPE The unit return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.11 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusContainmtDPUS OBJECT-TYPE The unit containment differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.12 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusContainmtDPMetric OBJECT-TYPE The unit containment differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.13 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusFilterDPUS OBJECT-TYPE The unit air filter differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.14 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusFilterDPMetric OBJECT-TYPE The unit air filter differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.15 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusFanSpeed OBJECT-TYPE The unit average fan speed in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.16 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusInputState OBJECT-TYPE The state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.17 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRRCUnitStatusOutputState OBJECT-TYPE The state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.18 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRRCUnitStatusActivePowerSource OBJECT-TYPE The power source that is powering the unit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.19 | INTEGER {sourceA(1), sourceB(2)} | read-only | mandatory |
| airIRRCUnitStatusFluidValvePosition OBJECT-TYPE The fluid valve position in percent open. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.20 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusFluidFlowUS OBJECT-TYPE The fluid flow in tenths of gallons per minute. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.21 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusFluidFlowMetric OBJECT-TYPE The fluid flow in hundredths of liters per second. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.22 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusEnteringFluidTemperatureUS OBJECT-TYPE The temperature of the entering fluid in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.23 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusEnteringFluidTemperatureMetric OBJECT-TYPE The temperature of the entering fluid in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.24 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusLeavingFluidTemperatureUS OBJECT-TYPE The temperature of the Leaving fluid in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.25 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusLeavingFluidTemperatureMetric OBJECT-TYPE The temperature of the Leaving fluid in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.26 | INTEGER | read-only | mandatory |
| airIRRCUnitStatusLeakSensor OBJECT-TYPE The state (no-leak/leak) of the leak sensor. | 1.3.6.1.4.1.318.1.1.13.3.2.2.2.27 | INTEGER {no-leak(1), leak(2)} | read-only | mandatory |
| airIRRCUnitRunHours OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2.3 | |||
| airIRRCUnitRunHoursAirFilter OBJECT-TYPE Unit air filter run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.1 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan1 OBJECT-TYPE Unit fan 1 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.2 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan2 OBJECT-TYPE Unit fan 2 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.3 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan3 OBJECT-TYPE Unit fan 3 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.4 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan4 OBJECT-TYPE Unit fan 4 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.5 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan5 OBJECT-TYPE Unit fan 5 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.6 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan6 OBJECT-TYPE Unit fan 6 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.7 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan7 OBJECT-TYPE Unit fan 7 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.8 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFan8 OBJECT-TYPE Unit fan 8 run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.9 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFanPowerSupplyLeft OBJECT-TYPE Unit fan left power supply run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.10 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFanPowerSupplyRight OBJECT-TYPE Unit fan right power supply run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.11 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursCondensatePump OBJECT-TYPE Unit condensate pump run hours. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.12 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFanPowerSupplyFeedALeft OBJECT-TYPE Unit fan, DC power feed A, left power supply run hours. This is only valid for a DC input unit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.13 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFanPowerSupplyFeedARight OBJECT-TYPE Unit fan, DC power feed A, right power supply run hours. This is only valid for a DC input unit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.14 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFanPowerSupplyFeedBLeft OBJECT-TYPE Unit fan, DC power feed B, left power supply run hours. This is only valid for a DC input unit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.15 | INTEGER | read-only | mandatory |
| airIRRCUnitRunHoursFanPowerSupplyFeedBRight OBJECT-TYPE Unit fan, DC power feed B, right power supply run hours. This is only valid for a DC input unit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.3.16 | INTEGER | read-only | mandatory |
| airIRRCUnitServiceIntervals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2.4 | |||
| airIRRCUnitServiceIntervalsAirFilter OBJECT-TYPE Air filter service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.2.2.4.1 | INTEGER | read-write | mandatory |
| airIRRCUnitServiceIntervalsAirFilterAlarm OBJECT-TYPE The air filter service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.2.2.4.2 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRCUnitThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2.5 | |||
| airIRRCUnitThresholdsRackInletHighTempUS OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.1 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsRackInletHighTempMetric OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.2 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsSupplyAirHighTempUS OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.3 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.4 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsReturnAirHighTempUS OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.5 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsReturnAirHighTempMetric OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.6 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsEnteringFluidHighTempUS OBJECT-TYPE Unit entering fluid high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.7 | INTEGER | read-write | mandatory |
| airIRRCUnitThresholdsEnteringFluidHighTempMetric OBJECT-TYPE Unit incoming fluid high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.2.2.5.8 | INTEGER | read-write | mandatory |
| airIRRCUnitConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.2.2.6 | |||
| airIRRCUnitConfigCoolCapacity OBJECT-TYPE The cooling capacity options setting. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.1 | INTEGER {automatic(1), maximum(2)} | read-write | mandatory |
| airIRRCUnitConfigStartupDelay OBJECT-TYPE The startup delay in seconds. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.2 | INTEGER | read-write | mandatory |
| airIRRCUnitConfigIdleOnLeakDetect OBJECT-TYPE The idle on leak options setting. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| airIRRCUnitConfigPowerSource OBJECT-TYPE The configured power source of the unit. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.4 | INTEGER {sourceA(1), sourceB(2), sourceAandB(3)} | read-write | mandatory |
| airIRRCUnitConfigInputNormalState OBJECT-TYPE The normal state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRRCUnitConfigOutputNormalState OBJECT-TYPE The normal state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.6 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRRCUnitConfigOutputSource OBJECT-TYPE The source of output relay change. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.7 | INTEGER {anyAlarm(1), criticalAlarm(2)} | read-write | mandatory |
| airIRRCUnitConfigIdleOnCoolFail OBJECT-TYPE The idle on cool fail options setting. If yes, the system will go into idle mode when a cooling failure is detected. If no, the system will not go into idle mode when a cooling failure is detected. | 1.3.6.1.4.1.318.1.1.13.3.2.2.6.8 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| airIRRP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3 | |||
| airIRRP100 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1 | |||
| airIRRP100Group OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.1 | |||
| airIRRP100GroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1 | |||
| airIRRP100GroupStatusAirFlowUS OBJECT-TYPE Group air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.1 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusAirFlowMetric OBJECT-TYPE Group air flow in liters per second. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.2 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusMaxRackInletTempUS OBJECT-TYPE Group maximum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.3 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusMaxRackInletTempMetric OBJECT-TYPE Group maximum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.4 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusMinRackInletTempUS OBJECT-TYPE Group minimum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.5 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusMinRackInletTempMetric OBJECT-TYPE Group minimum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.6 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusCoolDemand OBJECT-TYPE Group coolant demand in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.7 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusCoolOutput OBJECT-TYPE Group coolant output in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.8 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusHumidifyDemand OBJECT-TYPE The amount of humidification the group is demanding from the humidifiers in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.9 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusHumidifyOutput OBJECT-TYPE The actual amount of humidification the group is supplying in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.10 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusDehumidifyDemand OBJECT-TYPE The amount of dehumidification the group is demanding from the electric heaters in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.11 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusDehumidifyOutput OBJECT-TYPE The actual amount of dehumidification the group is supplying in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.12 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusReheatDemand OBJECT-TYPE The amount of heating the group is demanding from the electric heaters in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.13 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusReheatOutput OBJECT-TYPE The actual amount of heating the group is supplying in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.14 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusActiveFlowControlStatus OBJECT-TYPE Status of the active flow control system. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.15 | INTEGER {under(1), okay(2), over(3), notApplicable(4)} | read-only | mandatory |
| airIRRP100GroupStatusDewPointTempUS OBJECT-TYPE Group average dew point temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.16 | INTEGER | read-only | mandatory |
| airIRRP100GroupStatusDewPointTempMetric OBJECT-TYPE Group average dew point temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.17 | INTEGER | read-only | mandatory |
| airIRRP100GroupSetpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2 | |||
| airIRRP100GroupSetpointsCoolUS OBJECT-TYPE Group cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.1 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsCoolMetric OBJECT-TYPE Group cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.2 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsSupplyAirUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.3 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsSupplyAirMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.4 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsHumidify OBJECT-TYPE Group humidify setpoint in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.5 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsDehumidify OBJECT-TYPE Group dehumidify setpoint in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.6 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsDehumidifyDeadband OBJECT-TYPE Group dehumidify deadband in percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.7 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsReheatUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.8 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsReheatMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.9 | INTEGER | read-write | mandatory |
| airIRRP100GroupSetpointsFanSpeedPreference OBJECT-TYPE The preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.10 | INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)} | read-write | mandatory |
| airIRRP100GroupSetpointsFanSpeedControl OBJECT-TYPE The fan speed control setting. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.11 | INTEGER {automatic(1), manual(2)} | read-write | mandatory |
| airIRRP100GroupSetpointsActiveFlowControlBias OBJECT-TYPE The active flow control bias setting. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.12 | INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)} | read-write | mandatory |
| airIRRP100GroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3 | |||
| airIRRP100GroupConfigNumberofCoolingUnits OBJECT-TYPE The number of cooling units present in the group. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.1 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigConfigurationType OBJECT-TYPE The group configuration type. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.2 | INTEGER {racs(1), hacs(2), in-row(3), cacs(4)} | read-write | mandatory |
| airIRRP100GroupConfigCoolGainP OBJECT-TYPE The gain component of the cool PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.3 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigCoolResetRateI OBJECT-TYPE The integral component of the cool PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.4 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigCoolDerivativeD OBJECT-TYPE The derivative component of the cool PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.5 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigHumidifySensitivityBand OBJECT-TYPE The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.6 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigReheatGainP OBJECT-TYPE The gain component of the reheat PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.7 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigReheatResetRateI OBJECT-TYPE The integral component of the reheat PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.8 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigReheatDerivativeD OBJECT-TYPE The derivative component of the reheat PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.9 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigNumberofBackupUnits OBJECT-TYPE The number of backup units. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.10 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigRuntimeBalancingEnable OBJECT-TYPE Enable or disable runtime balancing feature. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.11 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRRP100GroupConfigLoadAssistEnable OBJECT-TYPE Enable or disable load assist feature. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.12 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRRP100GroupConfigFullRPBackups OBJECT-TYPE The number of full featured RPs that can be used as backup units. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.13 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigMaxFanSpeed OBJECT-TYPE The maximum desired fan speed setting in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.14 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigNumberOfActiveFlowControllers OBJECT-TYPE The number of active flow controllers present in the group. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.15 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigActiveFlowControllerLampTest OBJECT-TYPE Turns off/on the active flow controller lamp test. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.16 | INTEGER {off(1), on(2)} | read-write | mandatory |
| airIRRP100GroupConfigAltitudeUS OBJECT-TYPE The group altitude of the units above sea level in feet. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.17 | INTEGER | read-write | mandatory |
| airIRRP100GroupConfigAltitudeMetric OBJECT-TYPE The group altitude of the units above sea level in meters. | 1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.18 | INTEGER | read-write | mandatory |
| airIRRP100Unit OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2 | |||
| airIRRP100UnitIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1 | |||
| airIRRP100UnitIdentID OBJECT-TYPE The unit identification number. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.1 | INTEGER | read-write | mandatory |
| airIRRP100UnitIdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.2 | DisplayString | read-write | mandatory |
| airIRRP100UnitIdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.3 | DisplayString | read-write | mandatory |
| airIRRP100UnitIdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.4 | DisplayString | read-only | mandatory |
| airIRRP100UnitIdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.5 | DisplayString | read-only | mandatory |
| airIRRP100UnitIdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.6 | DisplayString | read-only | mandatory |
| airIRRP100UnitIdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.7 | DisplayString | read-only | mandatory |
| airIRRP100UnitIdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.8 | DisplayString | read-only | mandatory |
| airIRRP100UnitStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2 | |||
| airIRRP100UnitStatusOperateMode OBJECT-TYPE The cooling unit operating mode. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.1 | INTEGER {standby(1), on(2), idle(3), prestart(4), service(5), backup(6), assist(7)} | read-only | mandatory |
| airIRRP100UnitStatusRackInletTempUS OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.2 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusRackInletTempMetric OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.3 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusSupplyAirTempUS OBJECT-TYPE The unit supply air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.4 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusSupplyAirTempMetric OBJECT-TYPE The unit supply air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.5 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusReturnAirTempUS OBJECT-TYPE The unit return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.6 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusReturnAirTempMetric OBJECT-TYPE The unit return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.7 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusSupplyHumidity OBJECT-TYPE The relative humidity of the supply air in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusReturnHumidity OBJECT-TYPE The relative humidity of the return air in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.9 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusAirFlowUS OBJECT-TYPE The unit air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.10 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusAirFlowMetric OBJECT-TYPE The unit air flow in hundredths of liters per second. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.11 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusFanSpeed OBJECT-TYPE The unit average fan speed in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.12 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCoolDemand OBJECT-TYPE The unit cooling demand in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.13 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCoolOutput OBJECT-TYPE The unit cooling output in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.14 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusHumidifyDemand OBJECT-TYPE The amount of humidification the unit is demanding from the humidifier in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.15 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusHumidifyOutput OBJECT-TYPE The actual humidification output of the unit in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.16 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusDehumidifyDemand OBJECT-TYPE The amount of dehumidification the unit is demanding in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.17 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusDehumidifyOutput OBJECT-TYPE The actual dehumidification output of the unit in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.18 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusReheatDemand OBJECT-TYPE The amount of heating the unit is demanding from the electric heater in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.19 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusReheatOutput OBJECT-TYPE The actual heating output of the unit in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.20 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusInputState OBJECT-TYPE The state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.21 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRRP100UnitStatusOutputState OBJECT-TYPE The state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.22 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRRP100UnitStatusRackInletTemperature1US OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.23 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusRackInletTemperature1Metric OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.24 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusRackInletTemperature2US OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.25 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusRackInletTemperature2Metric OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.26 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusRackInletTemperature3US OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.27 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusRackInletTemperature3Metric OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.28 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusFilterDPUS OBJECT-TYPE The unit air filter differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.29 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusFilterDPMetric OBJECT-TYPE The unit air filter differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.30 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusContainmtDPUS OBJECT-TYPE The unit containment differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.31 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusContainmtDPMetric OBJECT-TYPE The unit containment differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.32 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusHumidifierCurrent OBJECT-TYPE The humidifier current of the unit in tenths of amperes. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.33 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusHumidifierWaterConductivity OBJECT-TYPE The water conductivity in the humidifier of the unit in microSiemens/cm. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.34 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveSpeed OBJECT-TYPE The compressor drive speed in hundredths of Hertz. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDrivePower OBJECT-TYPE The compressor drive power consumption in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.36 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveVoltage OBJECT-TYPE The compressor drive voltage consumption in tenths of volts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.37 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveCurrent OBJECT-TYPE The compressor drive voltage consumption in tenths of amperes. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.38 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveDCLinkVoltage OBJECT-TYPE The compressor drive DC link voltage in tenths of volts. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.39 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveHeatSinkTempUS OBJECT-TYPE The temperature of the compressor drive heatsink in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.40 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric OBJECT-TYPE The temperature of the compressor drive heatsink in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.41 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveControlCardTempUS OBJECT-TYPE The temperature of the compressor drive control card in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.42 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveControlCardTempMetric OBJECT-TYPE The temperature of the compressor drive control card in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.43 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveWarningStatus OBJECT-TYPE The four byte warning status of the compressor drive in hexadecimal. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.44 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusCompressorDriveAlarmStatus OBJECT-TYPE The four byte alarm status of the compressor drive in hexadecimal. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.45 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusSuctionPressureUS OBJECT-TYPE Unit suction pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.46 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusSuctionPressureMetric OBJECT-TYPE Unit suction pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.47 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusDischargePressureUS OBJECT-TYPE Unit discharge pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.48 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusDischargePressureMetric OBJECT-TYPE Unit discharge pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.49 | INTEGER | read-only | mandatory |
| airIRRP100UnitStatusLeakSensor OBJECT-TYPE The state (no-leak/leak) of the leak sensor. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.50 | INTEGER {no-leak(1), leak(2)} | read-only | mandatory |
| airIRRP100UnitRunHours OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3 | |||
| airIRRP100UnitRunHoursAirFilter OBJECT-TYPE Unit air filter run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.1 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursCondensatePump OBJECT-TYPE Unit condensate pump run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.2 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursHumidifier OBJECT-TYPE Unit fan right power supply run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.3 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursFan1 OBJECT-TYPE Unit fan 1 run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.4 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursHeater1 OBJECT-TYPE Unit heater 1 run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.5 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursFan2 OBJECT-TYPE Unit fan 2 run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.6 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursHeater2 OBJECT-TYPE Unit Heater 2 run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.7 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursCompressor OBJECT-TYPE Unit compressor run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.8 | INTEGER | read-only | mandatory |
| airIRRP100UnitRunHoursSystem OBJECT-TYPE Total system run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.9 | INTEGER | read-only | mandatory |
| airIRRP100UnitServiceIntervals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4 | |||
| airIRRP100UnitServiceIntervalAirFilter OBJECT-TYPE Air filter service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.1 | INTEGER | read-write | mandatory |
| airIRRP100UnitServiceIntervalAirFilterAlarm OBJECT-TYPE The air filter service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.2 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitServiceIntervalHumidifier OBJECT-TYPE Humidifier service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.3 | INTEGER | read-write | mandatory |
| airIRRP100UnitServiceIntervalHumidifierAlarm OBJECT-TYPE The humidifier service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.4 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitServiceIntervalHeater OBJECT-TYPE Heater service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.5 | INTEGER | read-write | mandatory |
| airIRRP100UnitServiceIntervalHeaterAlarm OBJECT-TYPE The heater service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.6 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitServiceIntervalCompressor OBJECT-TYPE Compressor service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.7 | INTEGER | read-write | mandatory |
| airIRRP100UnitServiceIntervalCompressorAlarm OBJECT-TYPE The compressor service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.8 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitServiceIntervalCondensatePump OBJECT-TYPE Condensate pump service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.9 | INTEGER | read-write | mandatory |
| airIRRP100UnitServiceIntervalCondensatePumpAlarm OBJECT-TYPE The condensate pump service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.10 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitServiceIntervalFans OBJECT-TYPE Fans service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.11 | INTEGER | read-write | mandatory |
| airIRRP100UnitServiceIntervalFansAlarm OBJECT-TYPE The fans service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.12 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5 | |||
| airIRRP100UnitThresholdsRackInletHighTempUS OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.1 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsRackInletHighTempMetric OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.2 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsSupplyAirHighTempUS OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.3 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.4 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsReturnAirHighTempUS OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.5 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsReturnAirHighTempMetric OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.6 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsSupplyHumidityHigh OBJECT-TYPE Unit supply humidity high threshold in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.7 | INTEGER | read-write | mandatory |
| airIRRP100UnitThresholdsSupplyHumidityLow OBJECT-TYPE Unit supply humidity low threshold in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.8 | INTEGER | read-write | mandatory |
| airIRRP100UnitConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6 | |||
| airIRRP100UnitConfigStartupDelay OBJECT-TYPE The startup delay in seconds. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.1 | INTEGER | read-write | mandatory |
| airIRRP100UnitConfigCoolCapacity OBJECT-TYPE The cooling capacity options setting. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.2 | INTEGER {automatic(1), maximum(2)} | read-write | mandatory |
| airIRRP100UnitConfigIdleOnLeakDetect OBJECT-TYPE The idle on leak options setting. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| airIRRP100UnitConfigInputNormalState OBJECT-TYPE The normal state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.4 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRRP100UnitConfigOutputNormalState OBJECT-TYPE The normal state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRRP100UnitConfigOutputSource OBJECT-TYPE The source of output relay change. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.6 | INTEGER {anyAlarm(1), criticalAlarm(2)} | read-write | mandatory |
| airIRRP100UnitConfigHumidifyEnable OBJECT-TYPE Enable/disable humidification. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.7 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitConfigHumidifierControl OBJECT-TYPE The humidifier drain control. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.8 | INTEGER {auto(1), drainOff(2)} | read-write | mandatory |
| airIRRP100UnitConfigDehumidifyEnable OBJECT-TYPE Enable/disable dehumidification. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.9 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitConfigReheatEnable OBJECT-TYPE Enable/disable reheat. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.10 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitConfigHeatAssistEnable OBJECT-TYPE Enable/disable heat assist. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.11 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP100UnitConfigPowerSourceConfig OBJECT-TYPE Configure the input power source: (1) single feed or (2) dual feed. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.12 | INTEGER {single(1), dual(2)} | read-write | mandatory |
| airIRRP100UnitConfigUnitRoleOverride OBJECT-TYPE When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.13 | INTEGER {automatic(1), forcedOn(2)} | read-write | mandatory |
| airIRRP100UnitConfigSecondaryPowerFeedCapability OBJECT-TYPE Available on chilled water units. When the power source config setting is set to dual, setting this value to reduced (2) will inhibit the heater and humdifier when the unit is being powered from the secondary input. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.14 | INTEGER {full(1), reduced(2)} | read-write | mandatory |
| airIRRP100UnitConfigIdleOnCoolFail OBJECT-TYPE When this OID value is (1) enable, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals. | 1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.15 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2 | |||
| airIRRP500Group OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.1 | |||
| airIRRP500GroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1 | |||
| airIRRP500GroupStatusAirFlowUS OBJECT-TYPE Group air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.1 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusAirFlowMetric OBJECT-TYPE Group air flow in liters per second. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.2 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusMaxRackInletTempUS OBJECT-TYPE Group maximum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.3 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusMaxRackInletTempMetric OBJECT-TYPE Group maximum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.4 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusMinRackInletTempUS OBJECT-TYPE Group minimum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.5 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusMinRackInletTempMetric OBJECT-TYPE Group minimum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.6 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusCoolDemand OBJECT-TYPE Group coolant demand in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.7 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusCoolOutput OBJECT-TYPE Group coolant output in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.8 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusHumidifyDemand OBJECT-TYPE The amount of humidification the group is demanding from the humidifiers in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.9 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusHumidifyOutput OBJECT-TYPE The actual amount of humidification the group is supplying in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.10 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusDehumidifyDemand OBJECT-TYPE The amount of dehumidification the group is demanding from the electric heaters in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.11 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusDehumidifyOutput OBJECT-TYPE The actual amount of dehumidification the group is supplying in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.12 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusReheatDemand OBJECT-TYPE The amount of heating the group is demanding from the electric heaters in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.13 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusReheatOutput OBJECT-TYPE The actual amount of heating the group is supplying in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.14 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusActiveFlowControlStatus OBJECT-TYPE Status of the active flow control system. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.15 | INTEGER {under(1), okay(2), over(3), notApplicable(4)} | read-only | mandatory |
| airIRRP500GroupStatusDewPointTempUS OBJECT-TYPE Group average dew point temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.16 | INTEGER | read-only | mandatory |
| airIRRP500GroupStatusDewPointTempMetric OBJECT-TYPE Group average dew point temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.17 | INTEGER | read-only | mandatory |
| airIRRP500GroupSetpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2 | |||
| airIRRP500GroupSetpointsCoolUS OBJECT-TYPE Group cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.1 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsCoolMetric OBJECT-TYPE Group cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.2 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsSupplyAirUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.3 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsSupplyAirMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.4 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsHumidify OBJECT-TYPE Group humidify setpoint in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.5 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsDehumidify OBJECT-TYPE Group dehumidify setpoint in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.6 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsDehumidifyDeadband OBJECT-TYPE Group dehumidify deadband in percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.7 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsReheatUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.8 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsReheatMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.9 | INTEGER | read-write | mandatory |
| airIRRP500GroupSetpointsFanSpeedPreference OBJECT-TYPE The preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.10 | INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)} | read-write | mandatory |
| airIRRP500GroupSetpointsFanSpeedControl OBJECT-TYPE The fan speed control setting. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.11 | INTEGER {automatic(1), manual(2)} | read-write | mandatory |
| airIRRP500GroupSetpointsActiveFlowControlBias OBJECT-TYPE The active flow control bias setting. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.12 | INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)} | read-write | mandatory |
| airIRRP500GroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3 | |||
| airIRRP500GroupConfigNumberofCoolingUnits OBJECT-TYPE The number of cooling units. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.1 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigConfigurationType OBJECT-TYPE The group configuration type. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.2 | INTEGER {racs(1), hacs(2), in-row(3), cacs(4)} | read-write | mandatory |
| airIRRP500GroupConfigPercentGlycol OBJECT-TYPE The glycol mixture in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.3 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigCoolGainP OBJECT-TYPE The gain component of the cool PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.4 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigCoolResetRateI OBJECT-TYPE The integral component of the cool PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.5 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigCoolDerivativeD OBJECT-TYPE The derivative component of the cool PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.6 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigHumidifySensitivityBand OBJECT-TYPE The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.7 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigReheatGainP OBJECT-TYPE The gain component of the reheat PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.8 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigReheatResetRateI OBJECT-TYPE The integral component of the reheat PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.9 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigReheatDerivativeD OBJECT-TYPE The derivative component of the reheat PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.10 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigMaxFanSpeed OBJECT-TYPE The maximum desired fan speed setting in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.11 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigNumberofBackupUnits OBJECT-TYPE The number of backup units. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.12 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigRuntimeBalancingEnable OBJECT-TYPE Enable or disable runtime balancing feature. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.13 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRRP500GroupConfigLoadAssistEnable OBJECT-TYPE Enable or disable load assist feature. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.14 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRRP500GroupConfigFullRPBackups OBJECT-TYPE The number of full featured RPs that can be used as backup units. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.15 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigNumberOfActiveFlowControllers OBJECT-TYPE The number of active flow controllers present in the group. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.16 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigActiveFlowControllerLampTest OBJECT-TYPE Turns off/on the active flow controller lamp test. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.17 | INTEGER {off(1), on(2)} | read-write | mandatory |
| airIRRP500GroupConfigAltitudeUS OBJECT-TYPE The group altitude of the units above sea level in feet. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.18 | INTEGER | read-write | mandatory |
| airIRRP500GroupConfigAltitudeMetric OBJECT-TYPE The group altitude of the units above sea level in meters. | 1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.19 | INTEGER | read-write | mandatory |
| airIRRP500Unit OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2 | |||
| airIRRP500UnitIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1 | |||
| airIRRP500UnitIdentID OBJECT-TYPE The unit identification number. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.1 | INTEGER | read-write | mandatory |
| airIRRP500UnitIdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.2 | DisplayString | read-write | mandatory |
| airIRRP500UnitIdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.3 | DisplayString | read-write | mandatory |
| airIRRP500UnitIdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.4 | DisplayString | read-only | mandatory |
| airIRRP500UnitIdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.5 | DisplayString | read-only | mandatory |
| airIRRP500UnitIdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.6 | DisplayString | read-only | mandatory |
| airIRRP500UnitIdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.7 | DisplayString | read-only | mandatory |
| airIRRP500UnitIdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.8 | DisplayString | read-only | mandatory |
| airIRRP500UnitStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2 | |||
| airIRRP500UnitStatusOperateMode OBJECT-TYPE The cooling unit operating mode. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.1 | INTEGER {standby(1), on(2), idle(3), prestart(4), backup(5), assist(6)} | read-only | mandatory |
| airIRRP500UnitStatusMaximumRackInletTempUS OBJECT-TYPE The maximum unit rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.2 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusMaximumRackInletTempMetric OBJECT-TYPE The maximum unit rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.3 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusSupplyAirTempUS OBJECT-TYPE The unit supply air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.4 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusSupplyAirTempMetric OBJECT-TYPE The unit supply air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.5 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusReturnAirTempUS OBJECT-TYPE The unit return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.6 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusReturnAirTempMetric OBJECT-TYPE The unit return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.7 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusSupplyHumidity OBJECT-TYPE The relative humidity of the supply air in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusReturnHumidity OBJECT-TYPE The relative humidity of the return air in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.9 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusAirFlowUS OBJECT-TYPE The unit air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.10 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusAirFlowMetric OBJECT-TYPE The unit air flow in hundredths of liters per second. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.11 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusFanSpeed OBJECT-TYPE The unit average fan speed in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.12 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusCoolDemand OBJECT-TYPE The unit cooling demand in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.13 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusCoolOutput OBJECT-TYPE The unit cooling output in tenths of kiloWatts. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.14 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusHumidifyDemand OBJECT-TYPE The amount of humidification the unit is demanding from the humidifier in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.15 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusHumidifyOutput OBJECT-TYPE The actual humidification output of the unit in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.16 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusDehumidifyDemand OBJECT-TYPE The amount of dehumidification the unit is demanding in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.17 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusDehumidifyOutput OBJECT-TYPE The actual dehumidification output of the unit in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.18 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusReheatDemand OBJECT-TYPE The amount of heating the unit is demanding from the electric heater in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.19 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusReheatOutput OBJECT-TYPE The actual heating output of the unit in percent. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.20 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusInputState OBJECT-TYPE The state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.21 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRRP500UnitStatusOutputState OBJECT-TYPE The state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.22 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRRP500UnitStatusRackInletTemperature1US OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.23 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusRackInletTemperature1Metric OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.24 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusRackInletTemperature2US OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.25 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusRackInletTemperature2Metric OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.26 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusRackInletTemperature3US OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.27 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusRackInletTemperature3Metric OBJECT-TYPE The unit rack inlet temperature sensor in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.28 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusContainmtDPUS OBJECT-TYPE The unit containment differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.29 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusContainmtDPMetric OBJECT-TYPE The unit containment differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.30 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusFilterDPUS OBJECT-TYPE The unit air filter differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.31 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusFilterDPMetric OBJECT-TYPE The unit air filter differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.32 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusHumidifierCurrent OBJECT-TYPE The humidifier current of the unit in tenths of amperes. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.33 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusHumidifierWaterConductivity OBJECT-TYPE The water conductivity in the humidifier of the unit in microSiemens/cm. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.34 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusActivePowerSource OBJECT-TYPE The power source that is powering the unit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.35 | INTEGER {sourceA(1), sourceB(2)} | read-only | mandatory |
| airIRRP500UnitStatusFluidValvePosition OBJECT-TYPE The fluid valve position in percent open. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.36 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusFluidFlowUS OBJECT-TYPE The fluid flow in tenths of gallons per minute. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.37 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusFluidFlowMetric OBJECT-TYPE The fluid flow in hundredths of liters per second. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.38 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusEnteringFluidTemperatureUS OBJECT-TYPE The temperature of the entering fluid in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.39 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusEnteringFluidTemperatureMetric OBJECT-TYPE The temperature of the entering fluid in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.40 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusLeavingFluidTemperatureUS OBJECT-TYPE The temperature of the Leaving fluid in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.41 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusLeavingFluidTemperatureMetric OBJECT-TYPE The temperature of the Leaving fluid in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.42 | INTEGER | read-only | mandatory |
| airIRRP500UnitStatusLeakSensor OBJECT-TYPE The state (no-leak/leak) of the leak sensor. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.43 | INTEGER {no-leak(1), leak(2)} | read-only | mandatory |
| airIRRP500UnitRunHours OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3 | |||
| airIRRP500UnitRunHoursAirFilter OBJECT-TYPE Unit air filter run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.1 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursCondensatePump OBJECT-TYPE Unit condensate pump run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.2 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursHumidifier OBJECT-TYPE Unit fan right power supply run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.3 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursFan1 OBJECT-TYPE Unit fan 1 run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.4 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursHeater1 OBJECT-TYPE Unit heater 1 run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.5 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursFan2 OBJECT-TYPE Unit fan 2 run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.6 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursHeater2 OBJECT-TYPE Unit Heater 2 run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.7 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursFan3 OBJECT-TYPE Unit fan 3 run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.8 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursHeater3 OBJECT-TYPE Unit heater 3 run hours in hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.9 | INTEGER | read-only | mandatory |
| airIRRP500UnitRunHoursSystem OBJECT-TYPE Total system run hours. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.10 | INTEGER | read-only | mandatory |
| airIRRP500UnitServiceIntervals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4 | |||
| airIRRP500UnitServiceIntervalAirFilter OBJECT-TYPE Air filter service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.1 | INTEGER | read-write | mandatory |
| airIRRP500UnitServiceIntervalAirFilterAlarm OBJECT-TYPE The air filter service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.2 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitServiceIntervalHumidifier OBJECT-TYPE Humidifier service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.3 | INTEGER | read-write | mandatory |
| airIRRP500UnitServiceIntervalHumidifierAlarm OBJECT-TYPE The humidifier service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.4 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitServiceIntervalHeater OBJECT-TYPE Heater service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.5 | INTEGER | read-write | mandatory |
| airIRRP500UnitServiceIntervalHeaterAlarm OBJECT-TYPE The heater service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.6 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitServiceIntervalCondensatePump OBJECT-TYPE Condensate pump service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.7 | INTEGER | read-write | mandatory |
| airIRRP500UnitServiceIntervalCondensatePumpAlarm OBJECT-TYPE The condensate pump service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.8 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitServiceIntervalFans OBJECT-TYPE Fans service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.9 | INTEGER | read-write | mandatory |
| airIRRP500UnitServiceIntervalFansAlarm OBJECT-TYPE The fans service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.10 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5 | |||
| airIRRP500UnitThresholdsRackInletHighTempUS OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.1 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsRackInletHighTempMetric OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.2 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsSupplyAirHighTempUS OBJECT-TYPE Unit supply air temperature high threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.3 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE Unit supply air high temperature high threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.4 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsReturnAirHighTempUS OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.5 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsReturnAirHighTempMetric OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.6 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsReturnHumidityHigh OBJECT-TYPE Unit return humidity high threshold in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.7 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsReturnHumidityLow OBJECT-TYPE Unit return humidity low threshold in tenths of percent relative humidity. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.8 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsEnteringFluidHighTempUS OBJECT-TYPE Entering fluid high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.9 | INTEGER | read-write | mandatory |
| airIRRP500UnitThresholdsEnteringFluidHighTempMetric OBJECT-TYPE Entering fluid high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.10 | INTEGER | read-write | mandatory |
| airIRRP500UnitConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6 | |||
| airIRRP500UnitConfigStartupDelay OBJECT-TYPE The startup delay in seconds. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.1 | INTEGER | read-write | mandatory |
| airIRRP500UnitConfigCoolCapacity OBJECT-TYPE The cooling capacity options setting. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.2 | INTEGER {automatic(1), maximum(2)} | read-write | mandatory |
| airIRRP500UnitConfigIdleOnLeakDetect OBJECT-TYPE The idle on leak options setting. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| airIRRP500UnitConfigInputNormalState OBJECT-TYPE The normal state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.4 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRRP500UnitConfigOutputNormalState OBJECT-TYPE The normal state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRRP500UnitConfigOutputSource OBJECT-TYPE The source of output relay change. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.6 | INTEGER {anyAlarm(1), criticalAlarm(2)} | read-write | mandatory |
| airIRRP500UnitConfigHumidifyEnable OBJECT-TYPE Enable/disable humidification. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.7 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitConfigHumidifierControl OBJECT-TYPE The humidifier drain control. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.8 | INTEGER {auto(1), drainOff(2)} | read-write | mandatory |
| airIRRP500UnitConfigDehumidifyEnable OBJECT-TYPE Enable/disable dehumidification. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.9 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitConfigReheatEnable OBJECT-TYPE Enable/disable reheat. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.10 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitConfigHeatAssistEnable OBJECT-TYPE Enable/disable heat assist. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.11 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRRP500UnitConfigPowerSourceConfig OBJECT-TYPE Configure the input power source: (1) single feed or (2) dual feed. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.12 | INTEGER {single(1), dual(2)} | read-write | mandatory |
| airIRRP500UnitConfigUnitRoleOverride OBJECT-TYPE When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.13 | INTEGER {automatic(1), forcedOn(2)} | read-write | mandatory |
| airIRRP500UnitConfigSecondaryPowerFeedCapability OBJECT-TYPE Available on chilled water units. When the power source config setting is set to dual, setting this value to reduced (2) will inhibit the heater and humdifier when the unit is being powered from the secondary input. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.14 | INTEGER {full(1), reduced(2)} | read-write | mandatory |
| airIRRP500UnitConfigIdleOnCoolFail OBJECT-TYPE When this OID value is (1) enable, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals. | 1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.15 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4 | |||
| airIRSCUnit OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1 | |||
| airIRSCUnitIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.1 | |||
| airIRSCUnitIdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.1 | DisplayString | read-write | mandatory |
| airIRSCUnitIdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.2 | DisplayString | read-write | mandatory |
| airIRSCUnitIdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.3 | DisplayString | read-only | mandatory |
| airIRSCUnitIdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.4 | DisplayString | read-only | mandatory |
| airIRSCUnitIdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.5 | DisplayString | read-only | mandatory |
| airIRSCUnitIdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.6 | DisplayString | read-only | mandatory |
| airIRSCUnitIdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.3.4.1.1.7 | DisplayString | read-only | mandatory |
| airIRSCUnitStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.2 | |||
| airIRSCUnitStatusOperateMode OBJECT-TYPE The cooling unit operating mode. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.1 | INTEGER {standby(1), on(2), idle(3)} | read-only | mandatory |
| airIRSCUnitStatusCoolOutput OBJECT-TYPE The unit cooling output in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.2 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusCoolDemand OBJECT-TYPE The unit cooling demand in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.3 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusAirFlowUS OBJECT-TYPE The unit air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.4 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusAirFlowMetric OBJECT-TYPE The unit air flow in liters per second. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.5 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusRackInletTempUS OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.6 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusRackInletTempMetric OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.7 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSupplyAirTempUS OBJECT-TYPE The unit supply air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.8 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSupplyAirTempMetric OBJECT-TYPE The unit supply air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.9 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusReturnAirTempUS OBJECT-TYPE The unit return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.10 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusReturnAirTempMetric OBJECT-TYPE The unit return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.11 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSuctionTempUS OBJECT-TYPE The unit suction temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.12 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSuctionTempMetric OBJECT-TYPE The unit suction temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.13 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSuperheatTempUS OBJECT-TYPE The unit superheat temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.14 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSuperheatTempMetric OBJECT-TYPE The unit superheat temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.15 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusContainmtDPUS OBJECT-TYPE The unit containment differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.16 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusContainmtDPMetric OBJECT-TYPE The unit containment differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.17 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusFilterDPUS OBJECT-TYPE The unit air filter differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.18 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusFilterDPMetric OBJECT-TYPE The unit air filter differential pressure in Pa. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.19 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSuctionPressureUS OBJECT-TYPE Unit suction pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.20 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusSuctionPressureMetric OBJECT-TYPE Unit suction pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.21 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusDischargePressureUS OBJECT-TYPE Unit discharge pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.22 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusDischargePressureMetric OBJECT-TYPE Unit discharge pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.23 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusEvaporatorFanSpeed OBJECT-TYPE The unit average evaporator fan speed in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.24 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusCondenserFanSpeed OBJECT-TYPE The unit average condenser fan speed in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.25 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusInputState OBJECT-TYPE The state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.26 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRSCUnitStatusOutputState OBJECT-TYPE The state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.27 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRSCUnitStatusCondOutletTempUS OBJECT-TYPE The unit condenser outlet air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.28 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusCondOutletTempMetric OBJECT-TYPE The unit condenser outlet air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.29 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusCondInletTempUS OBJECT-TYPE The unit condenser inlet air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.30 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusCondInletTempMetric OBJECT-TYPE The unit condenser inlet air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.31 | INTEGER | read-only | mandatory |
| airIRSCUnitStatusCompressor OBJECT-TYPE The state (off/on) of the compressor. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.32 | INTEGER {off(1), on(2)} | read-only | mandatory |
| airIRSCUnitStatusLeakSensor OBJECT-TYPE The state (no-leak/leak) of the leak sensor. | 1.3.6.1.4.1.318.1.1.13.3.4.1.2.33 | INTEGER {no-leak(1), leak(2)} | read-only | mandatory |
| airIRSCUnitRunHours OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.3 | |||
| airIRSCUnitRunHoursAirFilter OBJECT-TYPE Unit air filter run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.1 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursEvaporatorFan1 OBJECT-TYPE Unit evaporator fan 1 run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.2 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursEvaporatorFan2 OBJECT-TYPE Unit evaporator fan 2 run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.3 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursEvaporatorFan3 OBJECT-TYPE Unit evaporator fan 3 run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.4 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursCondenserFan1 OBJECT-TYPE Unit condenser fan 1 run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.5 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursCondenserFan2 OBJECT-TYPE Unit condenser fan 2 run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.6 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursCondenserFan3 OBJECT-TYPE Unit condenser fan 3 run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.7 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursFanPowerSupplyLeft OBJECT-TYPE Unit fan left power supply run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.8 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursFanPowerSupplyRight OBJECT-TYPE Unit fan right power supply run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.9 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursCondensatePump OBJECT-TYPE Unit condensate pump run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.10 | INTEGER | read-only | mandatory |
| airIRSCUnitRunHoursCompressor OBJECT-TYPE Unit compressor run hours. | 1.3.6.1.4.1.318.1.1.13.3.4.1.3.11 | INTEGER | read-only | mandatory |
| airIRSCUnitServiceIntervals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.4 | |||
| airIRSCUnitServiceIntervalsAirFilter OBJECT-TYPE Air filter service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.3.4.1.4.1 | INTEGER | read-write | mandatory |
| airIRSCUnitServiceIntervalsAirFilterAlarm OBJECT-TYPE The air filter service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.3.4.1.4.2 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRSCUnitThresholds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.5 | |||
| airIRSCUnitThresholdsRackInletHighTempUS OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.5.1 | INTEGER | read-write | mandatory |
| airIRSCUnitThresholdsRackInletHighTempMetric OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.5.2 | INTEGER | read-write | mandatory |
| airIRSCUnitThresholdsSupplyAirHighTempUS OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.5.3 | INTEGER | read-write | mandatory |
| airIRSCUnitThresholdsSupplyAirHighTempMetric OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.5.4 | INTEGER | read-write | mandatory |
| airIRSCUnitThresholdsReturnAirHighTempUS OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.5.5 | INTEGER | read-write | mandatory |
| airIRSCUnitThresholdsReturnAirHighTempMetric OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.5.6 | INTEGER | read-write | mandatory |
| airIRSCUnitSetpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.6 | |||
| airIRSCUnitSetptsCoolSetpointUS OBJECT-TYPE Unit cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.1 | INTEGER | read-write | mandatory |
| airIRSCUnitSetptsCoolSetpointMetric OBJECT-TYPE Unit cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.2 | INTEGER | read-write | mandatory |
| airIRSCUnitSetptsCoolDeadbandUS OBJECT-TYPE Unit cooling deadband in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.3 | INTEGER | read-write | mandatory |
| airIRSCUnitSetptsCoolDeadbandMetric OBJECT-TYPE Unit cooling deadband in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.4 | INTEGER | read-write | mandatory |
| airIRSCUnitSetptsFanSpeedPreference OBJECT-TYPE The preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.5 | AirIRSCFanSpeedPreference | read-write | mandatory |
| airIRSCUnitSetptsSupplyAirSetpointUS OBJECT-TYPE Unit supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.6 | INTEGER | read-write | mandatory |
| airIRSCUnitSetptsSupplyAirSetpointMetric OBJECT-TYPE Unit supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.1.6.7 | INTEGER | read-write | mandatory |
| airIRSCUnitConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.1.7 | |||
| airIRSCUnitConfigConfigurationType OBJECT-TYPE The unit configuration type. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.1 | AirIRSCConfigType | read-write | mandatory |
| airIRSCUnitConfigCapacityControlType OBJECT-TYPE The unit capacity control. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.2 | AirIRSCCapacityControlType | read-write | mandatory |
| airIRSCUnitConfigStartupDelay OBJECT-TYPE The startup delay in seconds. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.3 | INTEGER | read-write | mandatory |
| airIRSCUnitConfigIdleOnLeakDetect OBJECT-TYPE The idle on leak options setting. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.4 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| airIRSCUnitConfigInputNormalState OBJECT-TYPE The normal state of the input contact. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRSCUnitConfigOutputNormalState OBJECT-TYPE The normal state of the output relay. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.6 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRSCUnitConfigOutputSource OBJECT-TYPE The source of output relay change. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.7 | INTEGER {anyAlarm(1), criticalAlarm(2)} | read-write | mandatory |
| airIRSCUnitConfigAltitudeUS OBJECT-TYPE The altitude of the unit above sea level in feet. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.8 | INTEGER | read-write | mandatory |
| airIRSCUnitConfigAltitudeMetric OBJECT-TYPE The altitude of the unit above sea level in meters. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.9 | INTEGER | read-write | mandatory |
| airIRSCUnitConfigOpControl OBJECT-TYPE The unit operational control. | 1.3.6.1.4.1.318.1.1.13.3.4.1.7.10 | INTEGER {standby(1), on(2)} | read-write | mandatory |
| airIRSCGroup OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.2 | |||
| airIRSCGroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.2.1 | |||
| airIRSCGroupStatusCoolOutput OBJECT-TYPE The group cooling output in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.1 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusCoolDemand OBJECT-TYPE The group cooling demand in tenths of kW. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.2 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusAirFlowUS OBJECT-TYPE The group air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.3 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusAirFlowMetric OBJECT-TYPE The group air flow in liters per second. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.4 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMaxRackInletTempUS OBJECT-TYPE The group maximum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.5 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMaxRackInletTempMetric OBJECT-TYPE The group maximum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.6 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMinRackInletTempUS OBJECT-TYPE The group minimum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.7 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMinRackInletTempMetric OBJECT-TYPE The group minimum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.8 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMaxReturnAirTempUS OBJECT-TYPE The group maximum return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.9 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMaxReturnAirTempMetric OBJECT-TYPE The group maximum return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.10 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMinReturnAirTempUS OBJECT-TYPE The group minimum return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.11 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusMinReturnAirTempMetric OBJECT-TYPE The group minimum return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.12 | INTEGER | read-only | mandatory |
| airIRSCGroupStatusActiveFlowControlStatus OBJECT-TYPE Status of the active flow control system. | 1.3.6.1.4.1.318.1.1.13.3.4.2.1.13 | INTEGER {under(1), okay(2), over(3), notApplicable(4)} | read-only | mandatory |
| airIRSCGroupSetpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.2.2 | |||
| airIRSCGroupSetptsCoolSetpointUS OBJECT-TYPE Group cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.1 | INTEGER | read-write | mandatory |
| airIRSCGroupSetptsCoolSetpointMetric OBJECT-TYPE Group cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.2 | INTEGER | read-write | mandatory |
| airIRSCGroupSetptsCoolDeadbandUS OBJECT-TYPE Group cooling deadband in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.3 | INTEGER | read-write | mandatory |
| airIRSCGroupSetptsCoolDeadbandMetric OBJECT-TYPE Group cooling deadband in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.4 | INTEGER | read-write | mandatory |
| airIRSCGroupSetptsFanSpeedPreference OBJECT-TYPE The group preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.5 | AirIRSCFanSpeedPreference | read-write | mandatory |
| airIRSCGroupSetptsSupplyAirSetpointUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.6 | INTEGER | read-write | mandatory |
| airIRSCGroupSetptsSupplyAirSetpointMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.7 | INTEGER | read-write | mandatory |
| airIRSCGroupSetpointsActiveFlowControlBias OBJECT-TYPE The active flow control bias setting. | 1.3.6.1.4.1.318.1.1.13.3.4.2.2.8 | INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)} | read-write | mandatory |
| airIRSCGroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.3.4.2.3 | |||
| airIRSCGroupConfigNumberofCoolingUnits OBJECT-TYPE The number of cooling units. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.1 | INTEGER | read-write | mandatory |
| airIRSCGroupConfigConfigurationType OBJECT-TYPE The group configuration type. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.2 | AirIRSCConfigType | read-write | mandatory |
| airIRSCGroupConfigCapacityControlType OBJECT-TYPE The group capacity control. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.3 | AirIRSCCapacityControlType | read-write | mandatory |
| airIRSCGroupConfigAltitudeUS OBJECT-TYPE The group altitude of the units above sea level in feet. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.4 | INTEGER | read-write | mandatory |
| airIRSCGroupConfigAltitudeMetric OBJECT-TYPE The group altitude of the units above sea level in meters. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.5 | INTEGER | read-write | mandatory |
| airIRSCGroupConfigFanSpeedControl OBJECT-TYPE The group fan speed control. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.6 | AirIRSCFanSpeedControl | read-write | mandatory |
| airIRSCGroupConfigNumberOfActiveFlowControllers OBJECT-TYPE The number of active flow controllers present in the group. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.7 | INTEGER | read-write | mandatory |
| airIRSCGroupConfigActiveFlowControllerLampTest OBJECT-TYPE Turns off/on the active flow controller lamp test. | 1.3.6.1.4.1.318.1.1.13.3.4.2.3.8 | INTEGER {off(1), on(2)} | read-write | mandatory |
| airIRGen2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4 | |||
| airIRG2Ident OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.1 | |||
| airIRG2IdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.4.1.1 | DisplayString | read-write | mandatory |
| airIRG2IdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.4.1.2 | DisplayString | read-write | mandatory |
| airIRG2IdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.4.1.3 | DisplayString | read-only | mandatory |
| airIRG2IdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.4.1.4 | DisplayString | read-only | mandatory |
| airIRG2IdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.4.1.5 | DisplayString | read-only | mandatory |
| airIRG2IdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.4.1.6 | DisplayString | read-only | mandatory |
| airIRG2IdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.4.1.7 | DisplayString | read-only | mandatory |
| airIRG2IdentUnitSysOID OBJECT-TYPE This OID contains an OID path to the device's top level unit data. | 1.3.6.1.4.1.318.1.1.13.4.1.8 | OBJECT IDENTIFIER | read-only | mandatory |
| airIRG2IdentGroupSysOID OBJECT-TYPE This OID contains an OID path to the device's top level group data. | 1.3.6.1.4.1.318.1.1.13.4.1.9 | OBJECT IDENTIFIER | read-only | mandatory |
| airIRG2Group OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.2 | |||
| airIRG2GroupStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.2.1 | |||
| airIRG2GroupStatusCoolOutput OBJECT-TYPE The group cooling output in tenths of kilowatts (kW). | 1.3.6.1.4.1.318.1.1.13.4.2.1.1 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusCoolDemand OBJECT-TYPE The group cooling demand in tenths of kilowatts (kW). | 1.3.6.1.4.1.318.1.1.13.4.2.1.2 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusAirFlowUS OBJECT-TYPE The group air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.4.2.1.3 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusAirFlowMetric OBJECT-TYPE The group air flow in hundredths of liters per second. | 1.3.6.1.4.1.318.1.1.13.4.2.1.4 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMaxRackInletTempUS OBJECT-TYPE The group maximum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.1.5 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMaxRackInletTempMetric OBJECT-TYPE The group maximum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.1.6 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMinRackInletTempUS OBJECT-TYPE The group minimum rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.1.7 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMinRackInletTempMetric OBJECT-TYPE The group minimum rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.1.8 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMaxReturnAirTempUS OBJECT-TYPE The group maximum return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.1.9 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMaxReturnAirTempMetric OBJECT-TYPE The group maximum return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.1.10 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMinReturnAirTempUS OBJECT-TYPE The group minimum return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.1.11 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusMinReturnAirTempMetric OBJECT-TYPE The group minimum return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.1.12 | INTEGER | read-only | mandatory |
| airIRG2GroupStatusActiveFlowControlStatus OBJECT-TYPE Status of the active flow control system. | 1.3.6.1.4.1.318.1.1.13.4.2.1.13 | INTEGER {under(1), okay(2), over(3), notApplicable(4)} | read-only | mandatory |
| airIRG2GroupSetpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.2.2 | |||
| airIRG2GroupSetptsCoolSetpointUS OBJECT-TYPE Group cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.2.1 | INTEGER | read-write | mandatory |
| airIRG2GroupSetptsCoolSetpointMetric OBJECT-TYPE Group cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.2.2 | INTEGER | read-write | mandatory |
| airIRG2GroupSetptsCoolDeadbandUS OBJECT-TYPE Group cooling deadband in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.2.3 | INTEGER | read-write | mandatory |
| airIRG2GroupSetptsCoolDeadbandMetric OBJECT-TYPE Group cooling deadband in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.2.4 | INTEGER | read-write | mandatory |
| airIRG2GroupSetptsFanSpeedPreference OBJECT-TYPE The group preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.4.2.2.5 | INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)} | read-write | mandatory |
| airIRG2GroupSetptsSupplyAirSetpointUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.2.2.6 | INTEGER | read-write | mandatory |
| airIRG2GroupSetptsSupplyAirSetpointMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.2.2.7 | INTEGER | read-write | mandatory |
| airIRG2GroupSetpointsActiveFlowControlBias OBJECT-TYPE The active flow control bias setting. | 1.3.6.1.4.1.318.1.1.13.4.2.2.8 | INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)} | read-write | mandatory |
| airIRG2GroupConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.2.3 | |||
| airIRG2GroupConfigNumberofCoolingUnits OBJECT-TYPE The number of cooling units. | 1.3.6.1.4.1.318.1.1.13.4.2.3.1 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigConfigurationType OBJECT-TYPE The group configuration type. | 1.3.6.1.4.1.318.1.1.13.4.2.3.2 | INTEGER {racs(1), spot(2), in-row(3), hacs(4), cacs(5)} | read-write | mandatory |
| airIRG2GroupConfigCapacityControlType OBJECT-TYPE The group capacity control. | 1.3.6.1.4.1.318.1.1.13.4.2.3.3 | INTEGER {discrete(1), proportional(2)} | read-write | mandatory |
| airIRG2GroupConfigFanSpeedControl OBJECT-TYPE The group fan speed control. | 1.3.6.1.4.1.318.1.1.13.4.2.3.4 | INTEGER {automatic(1), manual(2)} | read-write | mandatory |
| airIRG2GroupConfigCoolGainP OBJECT-TYPE The gain component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.4.2.3.5 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigCoolResetRateI OBJECT-TYPE The integral component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.4.2.3.6 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigCoolDerivativeD OBJECT-TYPE The derivative component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.4.2.3.7 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigCoolPIDReset OBJECT-TYPE Will reset the PID coefficients back to the factory defaults. | 1.3.6.1.4.1.318.1.1.13.4.2.3.8 | INTEGER {readBack(1), reset(2)} | read-write | mandatory |
| airIRG2GroupConfigNumberofBackupUnits OBJECT-TYPE The number of backup units. | 1.3.6.1.4.1.318.1.1.13.4.2.3.9 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigRuntimeBalancingEnable OBJECT-TYPE Enable or disable runtime balancing feature. | 1.3.6.1.4.1.318.1.1.13.4.2.3.10 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRG2GroupConfigLoadAssistEnable OBJECT-TYPE Enable or disable load assist feature. | 1.3.6.1.4.1.318.1.1.13.4.2.3.11 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRG2GroupConfigNumberOfActiveFlowControllers OBJECT-TYPE The number of active flow controllers present in the group. | 1.3.6.1.4.1.318.1.1.13.4.2.3.12 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigActiveFlowControllerLampTest OBJECT-TYPE Turns off/on the active flow controller lamp test. | 1.3.6.1.4.1.318.1.1.13.4.2.3.13 | INTEGER {off(1), on(2)} | read-write | mandatory |
| airIRG2GroupConfigAltitudeUS OBJECT-TYPE The group altitude of the units above sea level in feet. | 1.3.6.1.4.1.318.1.1.13.4.2.3.14 | INTEGER | read-write | mandatory |
| airIRG2GroupConfigAltitudeMetric OBJECT-TYPE The group altitude of the units above sea level in meters. | 1.3.6.1.4.1.318.1.1.13.4.2.3.15 | INTEGER | read-write | mandatory |
| airIRG2Alarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.3 | |||
| airIRG2AlarmsTableSize OBJECT-TYPE The number of active alarms in the airIRG2AlarmsTable. | 1.3.6.1.4.1.318.1.1.13.4.3.1 | INTEGER | read-only | mandatory |
| airIRG2AlarmsTable OBJECT-TYPE Table of active alarms for the device. | 1.3.6.1.4.1.318.1.1.13.4.3.2 | not-accessible | mandatory | |
| airIRG2AlarmsEntry OBJECT-TYPE Alarms specification | 1.3.6.1.4.1.318.1.1.13.4.3.2.1 | not-accessible | mandatory | |
| airIRG2AlarmsIndex OBJECT-TYPE Alarm index. | 1.3.6.1.4.1.318.1.1.13.4.3.2.1.1 | INTEGER | read-only | mandatory |
| airIRG2AlarmsEventCode OBJECT-TYPE Code for the alarm. | 1.3.6.1.4.1.318.1.1.13.4.3.2.1.2 | INTEGER | read-only | mandatory |
| airIRG2AlarmsDescription OBJECT-TYPE Description of the alarm. | 1.3.6.1.4.1.318.1.1.13.4.3.2.1.3 | DisplayString (SIZE(0..64)) | read-only | mandatory |
| airIRG2RC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.4 | |||
| airIRG2RD OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5 | |||
| airIRG2RDType1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.1 | |||
| airIRG2RDType2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2 | |||
| airIRG2RDT2Status OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2.1 | |||
| airIRG2RDT2StatusOperateMode OBJECT-TYPE The cooling unit operating mode. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.1 | INTEGER {standby(1), on(2), idle(3), reserved(4), service(5)} | read-only | mandatory |
| airIRG2RDT2StatusCoolOutput OBJECT-TYPE The unit cooling output in tenths of kilowatts (kW). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.2 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusCoolDemand OBJECT-TYPE The unit cooling demand in tenths of kilowatts (kW). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.3 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusAirFlowUS OBJECT-TYPE The unit air flow in cubic feet per minute. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.4 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusAirFlowMetric OBJECT-TYPE The unit air flow in liters per second. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.5 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusRackInletTempUS OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.6 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusRackInletTempMetric OBJECT-TYPE The unit rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.7 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSupplyAirTempUS OBJECT-TYPE The unit supply air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.8 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSupplyAirTempMetric OBJECT-TYPE The unit supply air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.9 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusReturnAirTempUS OBJECT-TYPE The unit return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.10 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusReturnAirTempMetric OBJECT-TYPE The unit return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.11 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSuctionTempUS OBJECT-TYPE The unit suction temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.12 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSuctionTempMetric OBJECT-TYPE The unit suction temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.13 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSuperheatTempUS OBJECT-TYPE The unit superheat temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.14 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSuperheatTempMetric OBJECT-TYPE The unit superheat temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.15 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusFilterDPUS OBJECT-TYPE The unit air filter differential pressure in hundredths of inches of water. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.16 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusFilterDPMetric OBJECT-TYPE The unit air filter differential pressure in pascals (Pa). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.17 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSuctionPressureUS OBJECT-TYPE Unit suction pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.18 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusSuctionPressureMetric OBJECT-TYPE Unit suction pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.19 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusDischargePressureUS OBJECT-TYPE Unit discharge pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.20 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusDischargePressureMetric OBJECT-TYPE Unit discharge pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.21 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusEvaporatorFanSpeed OBJECT-TYPE The unit average evaporator fan speed in tenths of percent. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.22 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusInputState OBJECT-TYPE The state of the input contact. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.23 | AirIRG2RDType2IOState | read-only | mandatory |
| airIRG2RDT2StatusOutputState OBJECT-TYPE The state of the output relay. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.24 | AirIRG2RDType2IOState | read-only | mandatory |
| airIRG2RDT2StatusOHEInputState OBJECT-TYPE The state of the outside heat exchanger(OHE) input contact. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.25 | AirIRG2RDType2IOState | read-only | mandatory |
| airIRG2RDT2StatusOHEOutputState OBJECT-TYPE The state of the outside heat exchanger(OHE) output relay. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.26 | AirIRG2RDType2IOState | read-only | mandatory |
| airIRG2RDT2StatusCompressor OBJECT-TYPE The state (off/on) of the compressor. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.27 | INTEGER {off(1), on(2)} | read-only | mandatory |
| airIRG2RDT2StatusFluidValvePos OBJECT-TYPE The position of the fluid valve in percent. This OID is only valid when airIRG2RDT2ConfigUnitType indicates fluidCooled(1). | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.28 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusHotGasBypassValvePos OBJECT-TYPE The position of the hot gas bypass valve in hundredths of percent. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.29 | INTEGER | read-only | mandatory |
| airIRG2RDT2StatusLeakSensor OBJECT-TYPE The state (no-leak/leak) of the leak sensor. | 1.3.6.1.4.1.318.1.1.13.4.5.2.1.30 | INTEGER {no-leak(1), leak(2)} | read-only | mandatory |
| airIRG2RDT2RunHours OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2.2 | |||
| airIRG2RDT2RunHoursAirFilter OBJECT-TYPE Unit air filter run hours. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.1 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursCondensatePump OBJECT-TYPE Unit condensate pump run hours. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.2 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursCompressor OBJECT-TYPE Unit compressor run hours. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.3 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursFanPSTableSize OBJECT-TYPE The number of entries in the run hour fan power supply table (airIRG2RDT2RunHoursFanPSTable). | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.4 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursFanPSTable OBJECT-TYPE Allows for getting run hour information from each power supply. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5 | not-accessible | mandatory | |
| airIRG2RDT2RunHoursFanPSEntry OBJECT-TYPE The run hours fan power supply table entry. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1 | not-accessible | mandatory | |
| airIRG2RDT2RunHoursFanPSIndex OBJECT-TYPE Index of run hours fan power supply table. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.1 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursFanPSHours OBJECT-TYPE Fan power supply run time in hours. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.2 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursFanPSPosition OBJECT-TYPE Position of fan power supply within the unit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.3 | INTEGER {upper(1), lower(2), left(3), right(4)} | read-only | mandatory |
| airIRG2RDT2RunHoursEvapFanTableSize OBJECT-TYPE The number of entries in the run hour evaporator fan table (airIRG2RDT2RunHoursEvapFanTable). | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.6 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursEvapFanTable OBJECT-TYPE Allows for getting information from each evaporator fan run hour in the system. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7 | not-accessible | mandatory | |
| airIRG2RDT2RunHoursEvapFanEntry OBJECT-TYPE Allows for getting information from each evaporator fan run hour in the system. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1 | not-accessible | mandatory | |
| airIRG2RDT2RunHoursEvapFanIndex OBJECT-TYPE Index of run hours evaporator fan table. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.1 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursEvapFanHours OBJECT-TYPE Evaporator fan run time in hours. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.2 | INTEGER | read-only | mandatory |
| airIRG2RDT2RunHoursUnit OBJECT-TYPE Unit run time in hours. | 1.3.6.1.4.1.318.1.1.13.4.5.2.2.8 | INTEGER | read-only | mandatory |
| airIRG2RDT2ServiceIntervals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2.3 | |||
| airIRG2RDT2ServiceIntervalsAirFilter OBJECT-TYPE Air filter service interval in weeks. | 1.3.6.1.4.1.318.1.1.13.4.5.2.3.1 | INTEGER | read-write | mandatory |
| airIRG2RDT2ServiceIntervalsAirFilterAlarm OBJECT-TYPE The air filter service interval alarm enable/disable. | 1.3.6.1.4.1.318.1.1.13.4.5.2.3.2 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRG2RDT2Thresholds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2.4 | |||
| airIRG2RDT2ThresholdsRackInletHighTempUS OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.4.1 | INTEGER | read-write | mandatory |
| airIRG2RDT2ThresholdsRackInletHighTempMetric OBJECT-TYPE Unit rack inlet air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.4.2 | INTEGER | read-write | mandatory |
| airIRG2RDT2ThresholdsSupplyAirHighTempUS OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.4.3 | INTEGER | read-write | mandatory |
| airIRG2RDT2ThresholdsSupplyAirHighTempMetric OBJECT-TYPE Unit supply air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.4.4 | INTEGER | read-write | mandatory |
| airIRG2RDT2ThresholdsReturnAirHighTempUS OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.4.5 | INTEGER | read-write | mandatory |
| airIRG2RDT2ThresholdsReturnAirHighTempMetric OBJECT-TYPE Unit return air high temperature threshold in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.4.5.2.4.6 | INTEGER | read-write | mandatory |
| airIRG2RDT2Setpoints OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2.5 | |||
| airIRG2RDT2Config OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.5.2.6 | |||
| airIRG2RDT2ConfigUnitType OBJECT-TYPE The type of the unit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.1 | INTEGER {fluidCooled(1), airCooled(2)} | read-only | mandatory |
| airIRG2RDT2ConfigStartupDelay OBJECT-TYPE The startup delay in seconds. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.2 | INTEGER | read-write | mandatory |
| airIRG2RDT2ConfigIdleOnLeakDetect OBJECT-TYPE The idle on leak options setting. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| airIRG2RDT2ConfigInputNormalState OBJECT-TYPE The normal state of the input contact. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.4 | AirIRG2RDType2IOState | read-write | mandatory |
| airIRG2RDT2ConfigOutputNormalState OBJECT-TYPE The normal state of the output relay. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.5 | AirIRG2RDType2IOState | read-write | mandatory |
| airIRG2RDT2ConfigOutputSource OBJECT-TYPE The source of output relay change. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.6 | INTEGER {anyAlarm(1), criticalAlarm(2)} | read-write | mandatory |
| airIRG2RDT2ConfigOHEInputNormalState OBJECT-TYPE The normal state of the outside heat exchanger(OHE) input relay. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.7 | AirIRG2RDType2IOState | read-write | mandatory |
| airIRG2RDT2ConfigUnitRoleOverride OBJECT-TYPE When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.8 | INTEGER {automatic(1), forcedOn(2)} | read-write | mandatory |
| airIRG2RDT2ConfigUnitIdleOnCoolFail OBJECT-TYPE When this OID value is (2) yes, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals. | 1.3.6.1.4.1.318.1.1.13.4.5.2.6.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| airIRG2SC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.6 | |||
| airIRG2RA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.4.7 | |||
| airInRoom OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5 | |||
| airIRmIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.1 | |||
| airIRmIdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.5.1.1 | DisplayString | read-write | mandatory |
| airIRmIdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.5.1.2 | DisplayString | read-write | mandatory |
| airIRmIdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.5.1.3 | DisplayString | read-only | mandatory |
| airIRmIdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.5.1.4 | DisplayString | read-only | mandatory |
| airIRmIdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.5.1.5 | DisplayString | read-only | mandatory |
| airIRmIdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.5.1.6 | DisplayString | read-only | mandatory |
| airIRmIdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.5.1.7 | DisplayString | read-only | mandatory |
| airIRmIdentSysOID OBJECT-TYPE This OID contains an OID path to the device's top level data. | 1.3.6.1.4.1.318.1.1.13.5.1.8 | OBJECT IDENTIFIER | read-only | mandatory |
| airIRmAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.2 | |||
| airIRmAlarmsTableSize OBJECT-TYPE The number of active alarms in the airIRG2AlarmsTable. | 1.3.6.1.4.1.318.1.1.13.5.2.1 | INTEGER | read-only | mandatory |
| airIRmAlarmsTable OBJECT-TYPE Table of active alarms for the device. | 1.3.6.1.4.1.318.1.1.13.5.2.2 | not-accessible | mandatory | |
| airIRmAlarmsEntry OBJECT-TYPE Alarms specification | 1.3.6.1.4.1.318.1.1.13.5.2.2.1 | not-accessible | mandatory | |
| airIRmAlarmsIndex OBJECT-TYPE Alarm index. | 1.3.6.1.4.1.318.1.1.13.5.2.2.1.1 | INTEGER | read-only | mandatory |
| airIRmAlarmsEventCode OBJECT-TYPE Code for the alarm. | 1.3.6.1.4.1.318.1.1.13.5.2.2.1.2 | INTEGER | read-only | mandatory |
| airIRmAlarmsDescription OBJECT-TYPE Description of the alarm. | 1.3.6.1.4.1.318.1.1.13.5.2.2.1.3 | DisplayString (SIZE(0..64)) | read-only | mandatory |
| airIRmPerimeter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3 | |||
| airIRmPmCommon1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.2 | |||
| airIRmPmUnitType OBJECT-TYPE Unit type (1). | 1.3.6.1.4.1.318.1.1.13.5.3.2.1 | INTEGER {mc(1), dx(2), cw(3), ch(4), ecoCool(5), msc(6), ge1(7), ge2(8), dualFluid(9), cw2(10), unknown(256)} | read-only | mandatory |
| airIRmPmSwVersion OBJECT-TYPE Software version (3). | 1.3.6.1.4.1.318.1.1.13.5.3.2.3 | DisplayString | read-only | mandatory |
| airIRmPmBusAddress OBJECT-TYPE Bus addresss of unit (5). | 1.3.6.1.4.1.318.1.1.13.5.3.2.5 | INTEGER (0..65535) | read-only | mandatory |
| airIRmPmControllerType OBJECT-TYPE Controller type (7). | 1.3.6.1.4.1.318.1.1.13.5.3.2.7 | INTEGER {unknown(1), c4000(2), c1001(3), c1002(4), c5000(5), c6000(6), c1010(7), c7000IOC(8), c7000AT(9), c7000PT(10), c5MSC(11), c7000PT2(12)} | read-only | mandatory |
| airIRmPmGeneralError OBJECT-TYPE General Error (8) | 1.3.6.1.4.1.318.1.1.13.5.3.2.8 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmErrorOnBus OBJECT-TYPE Error On Bus (9) | 1.3.6.1.4.1.318.1.1.13.5.3.2.9 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCommon2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.3 | |||
| airIRmPmPCStop OBJECT-TYPE PC-STOP (1000) | 1.3.6.1.4.1.318.1.1.13.5.3.3.1 | AirIRmStopState | read-only | mandatory |
| airIRmPmRemoteStop OBJECT-TYPE Remote Stop (1001) | 1.3.6.1.4.1.318.1.1.13.5.3.3.2 | AirIRmStopState | read-only | mandatory |
| airIRmPmLocalStop OBJECT-TYPE Local Stop (1002) | 1.3.6.1.4.1.318.1.1.13.5.3.3.3 | AirIRmStopState | read-only | mandatory |
| airIRmPmTimerStop OBJECT-TYPE Timer Stop (1003) | 1.3.6.1.4.1.318.1.1.13.5.3.3.4 | AirIRmStopState | read-only | mandatory |
| airIRmPmSeqStop OBJECT-TYPE Seq. Stop (1004) | 1.3.6.1.4.1.318.1.1.13.5.3.3.5 | AirIRmStopState | read-only | mandatory |
| airIRmPmRemoteUPS OBJECT-TYPE Remote UPS (1006) | 1.3.6.1.4.1.318.1.1.13.5.3.3.7 | INTEGER {off(1), on(2)} | read-only | mandatory |
| airIRmPmLocalUPS OBJECT-TYPE Local UPS (1007) | 1.3.6.1.4.1.318.1.1.13.5.3.3.8 | AirIRmActivityState | read-only | mandatory |
| airIRmPmCommonAlarm OBJECT-TYPE Common alarm (1010). | 1.3.6.1.4.1.318.1.1.13.5.3.3.11 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmResetAllAlarms OBJECT-TYPE Reset all alarms control (1011). | 1.3.6.1.4.1.318.1.1.13.5.3.3.12 | INTEGER {doNothing(1), reset(2)} | read-write | mandatory |
| airIRmPmUnitOnOff OBJECT-TYPE Unit running state (1013). | 1.3.6.1.4.1.318.1.1.13.5.3.3.14 | AirIRmControlState | read-only | mandatory |
| airIRmPmMaintenance OBJECT-TYPE Maintenance necessary state (1014). | 1.3.6.1.4.1.318.1.1.13.5.3.3.15 | INTEGER {notNecessary(1), necessary(2)} | read-only | mandatory |
| airIRmPmUnitTemperatureScale OBJECT-TYPE Current Unit Temperature Scale (1022). | 1.3.6.1.4.1.318.1.1.13.5.3.3.23 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| airIRmPmUnitWinterMode OBJECT-TYPE Winter or summer configuration mode (1023). | 1.3.6.1.4.1.318.1.1.13.5.3.3.24 | INTEGER {summer(1), winter(2)} | read-only | mandatory |
| airIRmPmDayNightMode OBJECT-TYPE Day or night configuration mode (1024). | 1.3.6.1.4.1.318.1.1.13.5.3.3.25 | INTEGER {day(1), night(2)} | read-only | mandatory |
| airIRmPmCommon3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4 | |||
| airIRmPmLastMaintenanceYear OBJECT-TYPE Last maintenance year (1160). | 1.3.6.1.4.1.318.1.1.13.5.3.4.1 | INTEGER | read-only | mandatory |
| airIRmPmLastMaintenanceMonth OBJECT-TYPE Last maintenance month (1161). | 1.3.6.1.4.1.318.1.1.13.5.3.4.2 | INTEGER (1..12) | read-only | mandatory |
| airIRmPmLastMaintenanceDay OBJECT-TYPE Last maintenance day (1162). | 1.3.6.1.4.1.318.1.1.13.5.3.4.3 | INTEGER (1..31) | read-only | mandatory |
| airIRmPmUnitMaintenanceInterval OBJECT-TYPE Unit maintenance interval in months (1163). | 1.3.6.1.4.1.318.1.1.13.5.3.4.4 | INTEGER (1..255) | read-only | mandatory |
| airIRmPmRuntimeUnit OBJECT-TYPE Runtime unit in hours (1164). | 1.3.6.1.4.1.318.1.1.13.5.3.4.5 | INTEGER | read-only | mandatory |
| airIRmPmStoptimeUnit OBJECT-TYPE Unit stoptime in hours (1165) | 1.3.6.1.4.1.318.1.1.13.5.3.4.6 | INTEGER | read-only | mandatory |
| airIRmPmRuntimeCooling OBJECT-TYPE Cooling runtime in hours (1166) | 1.3.6.1.4.1.318.1.1.13.5.3.4.7 | INTEGER | read-only | mandatory |
| airIRmPmRuntimeHeating OBJECT-TYPE Heating runtime in hours (1167) | 1.3.6.1.4.1.318.1.1.13.5.3.4.8 | INTEGER | read-only | mandatory |
| airIRmPmRuntimeHumidification OBJECT-TYPE Humidification runtime in hours (1168) | 1.3.6.1.4.1.318.1.1.13.5.3.4.9 | INTEGER | read-only | mandatory |
| airIRmPmRuntimeDehumidification OBJECT-TYPE Dehumidification runtime in hours (1169) | 1.3.6.1.4.1.318.1.1.13.5.3.4.10 | INTEGER | read-only | mandatory |
| airIRmPmUnitTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.11 | |||
| airIRmPmUnitTemperatureC OBJECT-TYPE Unit temperature in tenths of degrees Celsius (1170). | 1.3.6.1.4.1.318.1.1.13.5.3.4.11.1 | INTEGER | read-only | mandatory |
| airIRmPmUnitTemperatureF OBJECT-TYPE Unit temperature in tenths of degrees Fahrenheit (1170). | 1.3.6.1.4.1.318.1.1.13.5.3.4.11.2 | INTEGER | read-only | mandatory |
| airIRmPmUnitHumidity OBJECT-TYPE Unit humidity in tenths of %RH (1171). | 1.3.6.1.4.1.318.1.1.13.5.3.4.12 | INTEGER | read-only | mandatory |
| airIRmPmSetpointTemperatureDay OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.14 | |||
| airIRmPmSetpointTemperatureDayC OBJECT-TYPE Setpoint daytime temperature in tenths of degrees Celsius (1173). | 1.3.6.1.4.1.318.1.1.13.5.3.4.14.1 | INTEGER | read-write | mandatory |
| airIRmPmSetpointTemperatureDayF OBJECT-TYPE Setpoint daytime temperature in tenths of degrees Fahrenheit (1173). | 1.3.6.1.4.1.318.1.1.13.5.3.4.14.2 | INTEGER | read-write | mandatory |
| airIRmPmSetpointTemperatureNight OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.15 | |||
| airIRmPmSetpointTemperatureNightC OBJECT-TYPE Setpoint nighttime temperature in tenths of degrees Celsius (1174). | 1.3.6.1.4.1.318.1.1.13.5.3.4.15.1 | INTEGER | read-write | mandatory |
| airIRmPmSetpointTemperatureNightF OBJECT-TYPE Setpoint nighttime temperature in tenths of degrees Fahrenheit (1174). | 1.3.6.1.4.1.318.1.1.13.5.3.4.15.2 | INTEGER | read-write | mandatory |
| airIRmPmSetpointHumidity OBJECT-TYPE Setpoint humidity in tenths of %RH (1176). | 1.3.6.1.4.1.318.1.1.13.5.3.4.17 | INTEGER | read-write | mandatory |
| airIRmPmUnitControlType OBJECT-TYPE Current unit control type (1183). | 1.3.6.1.4.1.318.1.1.13.5.3.4.24 | INTEGER {room(1), supply(2), room-SupplyLimit(3), supply-RoomLimit(4)} | read-only | mandatory |
| airIRmPmWinterModeStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.29 | |||
| airIRmPmWinterModeStartTempC OBJECT-TYPE Winter mode start temperature in tenths of degrees Celsius (1188). | 1.3.6.1.4.1.318.1.1.13.5.3.4.29.1 | INTEGER | read-only | mandatory |
| airIRmPmWinterModeStartTempF OBJECT-TYPE Winter mode start temperature in tenths of degrees Fahrenheit (1188). | 1.3.6.1.4.1.318.1.1.13.5.3.4.29.2 | INTEGER | read-only | mandatory |
| airIRmPmWinterModeHysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.30 | |||
| airIRmPmWinterModeHysteresisK OBJECT-TYPE Winter mode hysteresis in tenths of Kelvins (1189) | 1.3.6.1.4.1.318.1.1.13.5.3.4.30.1 | INTEGER | read-only | mandatory |
| airIRmPmWinterModeHysteresisF OBJECT-TYPE Winter mode hysteresis in tenths of degrees Fahrenheit (1189) | 1.3.6.1.4.1.318.1.1.13.5.3.4.30.2 | INTEGER | read-only | mandatory |
| airIRmPmWaterTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.32 | |||
| airIRmPmWaterTemperatureC OBJECT-TYPE Water temperature in tenths of degrees Celsius (1191). | 1.3.6.1.4.1.318.1.1.13.5.3.4.32.1 | INTEGER | read-only | mandatory |
| airIRmPmWaterTemperatureF OBJECT-TYPE Water temperature in tenths of degrees Fahrenheit (1191). | 1.3.6.1.4.1.318.1.1.13.5.3.4.32.2 | INTEGER | read-only | mandatory |
| airIRmPmReturnAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.33 | |||
| airIRmPmReturnAirTemperatureC OBJECT-TYPE Return air temperature in tenths of degrees Celsius (1192). | 1.3.6.1.4.1.318.1.1.13.5.3.4.33.1 | INTEGER | read-only | mandatory |
| airIRmPmReturnAirTemperatureF OBJECT-TYPE Return air temperature in tenths of degrees Fahrenheit (1192). | 1.3.6.1.4.1.318.1.1.13.5.3.4.33.2 | INTEGER | read-only | mandatory |
| airIRmPmSupplyAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.34 | |||
| airIRmPmSupplyAirTemperatureC OBJECT-TYPE Supply air temperature in tenths of degrees Celsius (1193). | 1.3.6.1.4.1.318.1.1.13.5.3.4.34.1 | INTEGER | read-only | mandatory |
| airIRmPmSupplyAirTemperatureF OBJECT-TYPE Supply air temperature in tenths of degrees Fahrenheit (1193). | 1.3.6.1.4.1.318.1.1.13.5.3.4.34.2 | INTEGER | read-only | mandatory |
| airIRmPmReturnAirHumidity OBJECT-TYPE Return air humidity in tenths of %RH (1194). | 1.3.6.1.4.1.318.1.1.13.5.3.4.35 | INTEGER | read-only | mandatory |
| airIRmPmSupplyAirHumidity OBJECT-TYPE Supply air humidity in tenths of %RH (1195). | 1.3.6.1.4.1.318.1.1.13.5.3.4.36 | INTEGER | read-only | mandatory |
| airIRmPmOutsideAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.37 | |||
| airIRmPmOutsideAirTemperatureC OBJECT-TYPE Outside air temperature in tenths of degrees Celsius (1196) | 1.3.6.1.4.1.318.1.1.13.5.3.4.37.1 | INTEGER | read-only | mandatory |
| airIRmPmOutsideAirTemperatureF OBJECT-TYPE Outside air temperature in tenths of degrees Fahrenheit (1196) | 1.3.6.1.4.1.318.1.1.13.5.3.4.37.2 | INTEGER | read-only | mandatory |
| airIRmPmOutsideAirHumidity OBJECT-TYPE Outside air humidity in tenths of percent relative humidity (1197) | 1.3.6.1.4.1.318.1.1.13.5.3.4.38 | INTEGER | read-only | mandatory |
| airIRmPmCoolingPriority OBJECT-TYPE Cooling priority (1198). | 1.3.6.1.4.1.318.1.1.13.5.3.4.39 | INTEGER {ge(1), cw(2), dx(3)} | read-write | mandatory |
| airIRmPmWaterTemperature2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.4.43 | |||
| airIRmPmWaterTemperature2C OBJECT-TYPE Water temperature 2 in tenths of degrees Celsius (1202). | 1.3.6.1.4.1.318.1.1.13.5.3.4.43.1 | INTEGER | read-only | mandatory |
| airIRmPmWaterTemperature2F OBJECT-TYPE Water temperature 2 in tenths of degrees Fahrenheit (1202). | 1.3.6.1.4.1.318.1.1.13.5.3.4.43.2 | INTEGER | read-only | mandatory |
| airIRmPmRuntimeFreeCooling OBJECT-TYPE Freecooling runtime in hours (1203) | 1.3.6.1.4.1.318.1.1.13.5.3.4.44 | INTEGER | read-only | mandatory |
| airIRmPmRuntimeMixedModeFreeCooling OBJECT-TYPE Mixed mode freecooling runtime in hours (1203) | 1.3.6.1.4.1.318.1.1.13.5.3.4.45 | INTEGER | read-only | mandatory |
| airIRmPmCommon4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.5 | |||
| airIRmPmNumberOfCompressors OBJECT-TYPE Number of compressors (1761) | 1.3.6.1.4.1.318.1.1.13.5.3.5.4 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfSuctionValves OBJECT-TYPE Number of suction valves (1762) | 1.3.6.1.4.1.318.1.1.13.5.3.5.5 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfDryCoolers OBJECT-TYPE Number of drycoolers (1763) | 1.3.6.1.4.1.318.1.1.13.5.3.5.6 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfPumps OBJECT-TYPE Number of pumps (1764) | 1.3.6.1.4.1.318.1.1.13.5.3.5.7 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfElectricHeaters OBJECT-TYPE Number of electric heaters (1765) | 1.3.6.1.4.1.318.1.1.13.5.3.5.8 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfHumidifiers OBJECT-TYPE Number of humidifiers (1766) | 1.3.6.1.4.1.318.1.1.13.5.3.5.9 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfFans OBJECT-TYPE Number of fans (1767) | 1.3.6.1.4.1.318.1.1.13.5.3.5.10 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfLouvers OBJECT-TYPE Number of louvers (1768) | 1.3.6.1.4.1.318.1.1.13.5.3.5.11 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfSensors OBJECT-TYPE Number of sensors (1769) | 1.3.6.1.4.1.318.1.1.13.5.3.5.12 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfExternalAlarmInputs OBJECT-TYPE Number of external alarm inputs (1770) | 1.3.6.1.4.1.318.1.1.13.5.3.5.13 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfGECWValves OBJECT-TYPE Number of GE/CW valves (1771) | 1.3.6.1.4.1.318.1.1.13.5.3.5.14 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfHotGasReheat OBJECT-TYPE Number of hot gas reheaters (1772) | 1.3.6.1.4.1.318.1.1.13.5.3.5.15 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfPWWReheat OBJECT-TYPE Number of PWW reheaters (1773) | 1.3.6.1.4.1.318.1.1.13.5.3.5.16 | INTEGER | read-only | mandatory |
| airIRmPmNumberOfDehumidifiers OBJECT-TYPE Number of dehumidifiers (1774) | 1.3.6.1.4.1.318.1.1.13.5.3.5.17 | INTEGER | read-only | mandatory |
| airIRmPmCommon5 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6 | |||
| airIRmPmUnitEvaporationTemperature1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.1 | |||
| airIRmPmUnitEvaporationTemperature1C OBJECT-TYPE Unit evaporation temperature 1 in tenths of degrees Celsius (2232) | 1.3.6.1.4.1.318.1.1.13.5.3.6.1.1 | INTEGER | read-only | mandatory |
| airIRmPmUnitEvaporationTemperature1F OBJECT-TYPE Unit evaporation temperature 1 in tenths of degrees Fahrenheit (2232) | 1.3.6.1.4.1.318.1.1.13.5.3.6.1.2 | INTEGER | read-only | mandatory |
| airIRmPmUnitEvaporationPressure1 OBJECT-TYPE Unit evaporation pressure 1 in tenths of Bars (2233) | 1.3.6.1.4.1.318.1.1.13.5.3.6.2 | INTEGER | read-only | mandatory |
| airIRmPmUnitCondensationTemperature1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.3 | |||
| airIRmPmUnitCondensationTemperature1C OBJECT-TYPE Unit condensation temperature 1 in tenths of degrees Celsius (2234) | 1.3.6.1.4.1.318.1.1.13.5.3.6.3.1 | INTEGER | read-only | mandatory |
| airIRmPmUnitCondensationTemperature1F OBJECT-TYPE Unit condensation temperature 1 in tenths of degrees Fahrenheit (2234) | 1.3.6.1.4.1.318.1.1.13.5.3.6.3.2 | INTEGER | read-only | mandatory |
| airIRmPmUnitCondensationPressure1 OBJECT-TYPE Unit condensation pressure 1 in tenths of Bars (2235) | 1.3.6.1.4.1.318.1.1.13.5.3.6.4 | INTEGER | read-only | mandatory |
| airIRmPmMaxLimitReturnAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.8 | |||
| airIRmPmMaxLimitReturnAirTemperatureC OBJECT-TYPE Maximum limit return air temperature in tenths of degrees Celsius (2239). | 1.3.6.1.4.1.318.1.1.13.5.3.6.8.1 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitReturnAirTemperatureF OBJECT-TYPE Maximum limit return air temperature in tenths of degrees Fahrenheit (2239). | 1.3.6.1.4.1.318.1.1.13.5.3.6.8.2 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitReturnAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.9 | |||
| airIRmPmMinLimitReturnAirTemperatureC OBJECT-TYPE Minimum limit return air temperature in tenths of degrees Celsius (2240). | 1.3.6.1.4.1.318.1.1.13.5.3.6.9.1 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitReturnAirTemperatureF OBJECT-TYPE Minimum limit return air temperature in tenths of degrees Fahrenheit (2240). | 1.3.6.1.4.1.318.1.1.13.5.3.6.9.2 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitSupplyAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.10 | |||
| airIRmPmMaxLimitSupplyAirTemperatureC OBJECT-TYPE Maximum limit supply air temperature in tenths of degrees Celsius (2241). | 1.3.6.1.4.1.318.1.1.13.5.3.6.10.1 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitSupplyAirTemperatureF OBJECT-TYPE Maximum limit supply air temperature in tenths of degrees Fahrenheit (2241). | 1.3.6.1.4.1.318.1.1.13.5.3.6.10.2 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitSupplyAirTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.11 | |||
| airIRmPmMinLimitSupplyAirTemperatureC OBJECT-TYPE Minimum limit supply air temperature in tenths of degrees Celsius (2242). | 1.3.6.1.4.1.318.1.1.13.5.3.6.11.1 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitSupplyAirTemperatureF OBJECT-TYPE Minimum limit supply air temperature in tenths of degrees Fahrenheit (2242). | 1.3.6.1.4.1.318.1.1.13.5.3.6.11.2 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitWaterTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.12 | |||
| airIRmPmMaxLimitWaterTemperatureC OBJECT-TYPE Maximum limit water temperature in tenths of degrees Celsius (2243). | 1.3.6.1.4.1.318.1.1.13.5.3.6.12.1 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitWaterTemperatureF OBJECT-TYPE Maximum limit water temperature in tenths of degrees Fahrenheit (2243). | 1.3.6.1.4.1.318.1.1.13.5.3.6.12.2 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitWaterTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.13 | |||
| airIRmPmMinLimitWaterTemperatureC OBJECT-TYPE Minimum limit water temperature in tenths of degrees Celsius (2244). | 1.3.6.1.4.1.318.1.1.13.5.3.6.13.1 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitWaterTemperatureF OBJECT-TYPE Minimum limit water temperature in tenths of degrees Fahrenheit (2244). | 1.3.6.1.4.1.318.1.1.13.5.3.6.13.2 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitReturnAirHumidity OBJECT-TYPE Maximum limit return air humidity in tenths of %RH (2245). | 1.3.6.1.4.1.318.1.1.13.5.3.6.14 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitReturnAirHumidity OBJECT-TYPE Minimum limit return air humidity in tenths of %RH (2246). | 1.3.6.1.4.1.318.1.1.13.5.3.6.15 | INTEGER | read-write | mandatory |
| airIRmPmMaxLimitSupplyAirHumidity OBJECT-TYPE Maximum limit supply air humidity in tenths of %RH (2247). | 1.3.6.1.4.1.318.1.1.13.5.3.6.16 | INTEGER | read-write | mandatory |
| airIRmPmMinLimitSupplyAirHumidity OBJECT-TYPE Minimum limit supply air humidity in tenths of %RH (2248). | 1.3.6.1.4.1.318.1.1.13.5.3.6.17 | INTEGER | read-write | mandatory |
| airIRmPmLowPressureWinterDelay OBJECT-TYPE Winter mode low pressure delay in seconds (2249) | 1.3.6.1.4.1.318.1.1.13.5.3.6.18 | INTEGER | read-only | mandatory |
| airIRmPmUnitCondensationPressure2 OBJECT-TYPE Unit condensation pressure 2 in tenths of Bars (2250) | 1.3.6.1.4.1.318.1.1.13.5.3.6.19 | INTEGER | read-only | mandatory |
| airIRmPmUnitOverloadSwitch OBJECT-TYPE Unit overload switch setting in tenths of Kelvins (2251) | 1.3.6.1.4.1.318.1.1.13.5.3.6.20 | INTEGER | read-only | mandatory |
| airIRmPmUnitCondensationTemperature2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.41 | |||
| airIRmPmUnitCondensationTemperature2C OBJECT-TYPE Unit condensation temperature 2 in tenths of degrees Celsius (2272) | 1.3.6.1.4.1.318.1.1.13.5.3.6.41.1 | INTEGER | read-only | mandatory |
| airIRmPmUnitCondensationTemperature2F OBJECT-TYPE Unit condensation temperature 2 in tenths of degrees Fahrenheit (2272) | 1.3.6.1.4.1.318.1.1.13.5.3.6.41.2 | INTEGER | read-only | mandatory |
| airIRmPmUnitEvaporationPressure2 OBJECT-TYPE Unit evaporation pressure 2 in tenths of Bars (2273) | 1.3.6.1.4.1.318.1.1.13.5.3.6.42 | INTEGER | read-only | mandatory |
| airIRmPmUnitEvaporationTemperature2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.6.43 | |||
| airIRmPmUnitEvaporationTemperature2C OBJECT-TYPE Unit evaporation temperature 2 in tenths of degrees Celsius (2274) | 1.3.6.1.4.1.318.1.1.13.5.3.6.43.1 | INTEGER | read-only | mandatory |
| airIRmPmUnitEvaporationTemperature2F OBJECT-TYPE Unit evaporation temperature 2 in tenths of degrees Fahrenheit (2274) | 1.3.6.1.4.1.318.1.1.13.5.3.6.43.2 | INTEGER | read-only | mandatory |
| airIRmPmCompressor1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.7 | |||
| airIRmPmCmp1ManOperationActive OBJECT-TYPE Compressor 1 manual operation active (4401) | 1.3.6.1.4.1.318.1.1.13.5.3.7.2 | INTEGER {automatic(1), manual(2)} | read-only | mandatory |
| airIRmPmCmp1ManOperationState OBJECT-TYPE Compressor 1 manual operation state (4402) | 1.3.6.1.4.1.318.1.1.13.5.3.7.3 | AirIRmControlState | read-only | mandatory |
| airIRmPmCmp1Running OBJECT-TYPE Compressor 1 running (4403) | 1.3.6.1.4.1.318.1.1.13.5.3.7.4 | AirIRmActivityState | read-only | mandatory |
| airIRmPmCmp1StartTempSummer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.7.17 | |||
| airIRmPmCmp1StartTempSummerK OBJECT-TYPE Compressor 1 summer mode start temperature in tenths of Kelvins (4416) | 1.3.6.1.4.1.318.1.1.13.5.3.7.17.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp1StartTempSummerF OBJECT-TYPE Compressor 1 summer mode start temperature in tenths of degrees Fahrenheit (4416) | 1.3.6.1.4.1.318.1.1.13.5.3.7.17.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp1HysteresisSummer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.7.18 | |||
| airIRmPmCmp1HysteresisSummerK OBJECT-TYPE Compressor 1 summer mode hysteresis setting in tenths of Kelvins (4417) | 1.3.6.1.4.1.318.1.1.13.5.3.7.18.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp1HysteresisSummerF OBJECT-TYPE Compressor 1 summer mode hysteresis setting in tenths of Fahrenheit (4417) | 1.3.6.1.4.1.318.1.1.13.5.3.7.18.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp1StartTempWinter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.7.19 | |||
| airIRmPmCmp1StartTempWinterK OBJECT-TYPE Compressor 1 winter mode start temperature in tenths of Kelvins (4418) | 1.3.6.1.4.1.318.1.1.13.5.3.7.19.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp1StartTempWinterF OBJECT-TYPE Compressor 1 winter mode start temperature in tenths of degrees Fahrenheit (4418) | 1.3.6.1.4.1.318.1.1.13.5.3.7.19.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp1HysteresisWinter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.7.20 | |||
| airIRmPmCmp1HysteresisWinterK OBJECT-TYPE Compressor 1 Winter mode hysteresis setting in tenths of Kelvins (4419) | 1.3.6.1.4.1.318.1.1.13.5.3.7.20.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp1HysteresisWinterF OBJECT-TYPE Compressor 1 Winter mode hysteresis setting in tenths of Fahrenheit (4419) | 1.3.6.1.4.1.318.1.1.13.5.3.7.20.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp1Runtime OBJECT-TYPE Compressor 1 runtime in hours (4428) | 1.3.6.1.4.1.318.1.1.13.5.3.7.29 | INTEGER | read-only | mandatory |
| airIRmPmCompressor2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.8 | |||
| airIRmPmCmp2ManOperationActive OBJECT-TYPE Compressor 2 manual operation active (4501) | 1.3.6.1.4.1.318.1.1.13.5.3.8.2 | INTEGER {automatic(1), manual(2)} | read-only | mandatory |
| airIRmPmCmp2ManOperationState OBJECT-TYPE Compressor 2 manual operation state (4502) | 1.3.6.1.4.1.318.1.1.13.5.3.8.3 | AirIRmControlState | read-only | mandatory |
| airIRmPmCmp2Running OBJECT-TYPE Compressor 2 running (4503) | 1.3.6.1.4.1.318.1.1.13.5.3.8.4 | AirIRmActivityState | read-only | mandatory |
| airIRmPmCmp2StartTempSummer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.8.17 | |||
| airIRmPmCmp2StartTempSummerK OBJECT-TYPE Compressor 2 summer mode start temperature in tenths of Kelvins (4516) | 1.3.6.1.4.1.318.1.1.13.5.3.8.17.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp2StartTempSummerF OBJECT-TYPE Compressor 2 summer mode start temperature in tenths of degrees Fahrenheit (4516) | 1.3.6.1.4.1.318.1.1.13.5.3.8.17.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp2HysteresisSummer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.8.18 | |||
| airIRmPmCmp2HysteresisSummerK OBJECT-TYPE Compressor 2 summer mode hysteresis setting in tenths of Kelvins (4517) | 1.3.6.1.4.1.318.1.1.13.5.3.8.18.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp2HysteresisSummerF OBJECT-TYPE Compressor 2 summer mode hysteresis setting in tenths of Fahrenheit (4517) | 1.3.6.1.4.1.318.1.1.13.5.3.8.18.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp2StartTempWinter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.8.19 | |||
| airIRmPmCmp2StartTempWinterK OBJECT-TYPE Compressor 2 winter mode start temperature in tenths of Kelvins (4518) | 1.3.6.1.4.1.318.1.1.13.5.3.8.19.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp2StartTempWinterF OBJECT-TYPE Compressor 2 winter mode start temperature in tenths of degrees Fahrenheit (4518) | 1.3.6.1.4.1.318.1.1.13.5.3.8.19.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp2HysteresisWinter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.8.20 | |||
| airIRmPmCmp2HysteresisWinterK OBJECT-TYPE Compressor 2 Winter mode hysteresis setting in tenths of Kelvins (4519) | 1.3.6.1.4.1.318.1.1.13.5.3.8.20.1 | INTEGER | read-write | mandatory |
| airIRmPmCmp2HysteresisWinterF OBJECT-TYPE Compressor 2 Winter mode hysteresis setting in tenths of Fahrenheit (4519) | 1.3.6.1.4.1.318.1.1.13.5.3.8.20.2 | INTEGER | read-write | mandatory |
| airIRmPmCmp2Runtime OBJECT-TYPE Compressor 2 runtime in hours (4528) | 1.3.6.1.4.1.318.1.1.13.5.3.8.29 | INTEGER | read-only | mandatory |
| airIRmPmSuctionValve1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.9 | |||
| airIRmPmSuctionValve2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.10 | |||
| airIRmPmEheating1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.11 | |||
| airIRmPmEheating1ManOpEnable OBJECT-TYPE Electric heater #1 manual operation enable (4801) | 1.3.6.1.4.1.318.1.1.13.5.3.11.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating1Running OBJECT-TYPE Electric heater #1 running state (4803) | 1.3.6.1.4.1.318.1.1.13.5.3.11.4 | AirIRmControlState | read-only | mandatory |
| airIRmPmEheating1ManOpRunning OBJECT-TYPE Electric heater #1 running in manual operation mode (4804) | 1.3.6.1.4.1.318.1.1.13.5.3.11.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating1Type OBJECT-TYPE Electric heater #1 type (4808) | 1.3.6.1.4.1.318.1.1.13.5.3.11.9 | INTEGER {direct(1), pwm(2)} | read-only | mandatory |
| airIRmPmEheating1StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.11.10 | |||
| airIRmPmEheating1StartTemperatureK OBJECT-TYPE Electric heater #1 start temperature in tenths of Kelvins (4809) | 1.3.6.1.4.1.318.1.1.13.5.3.11.10.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating1StartTemperatureF OBJECT-TYPE Electric heater #1 start temperature in tenths of degrees Fahrenheit (4809) | 1.3.6.1.4.1.318.1.1.13.5.3.11.10.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating1Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.11.11 | |||
| airIRmPmEheating1HysteresisK OBJECT-TYPE Electric heater #1 hysteresis in tenths of Kelvins (4810) | 1.3.6.1.4.1.318.1.1.13.5.3.11.11.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating1HysteresisF OBJECT-TYPE Electric heater #1 hysteresis in tenths of degrees Fahrenheit (4810) | 1.3.6.1.4.1.318.1.1.13.5.3.11.11.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating1Runtime OBJECT-TYPE Electric heater #1 runtime in hours (4816) | 1.3.6.1.4.1.318.1.1.13.5.3.11.17 | INTEGER | read-only | mandatory |
| airIRmPmEheating2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.12 | |||
| airIRmPmEheating2ManOpEnable OBJECT-TYPE Electric heater #2 manual operation enable (4901) | 1.3.6.1.4.1.318.1.1.13.5.3.12.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating2Running OBJECT-TYPE Electric heater #2 running state (4903) | 1.3.6.1.4.1.318.1.1.13.5.3.12.4 | AirIRmControlState | read-only | mandatory |
| airIRmPmEheating2ManOpRunning OBJECT-TYPE Electric heater #2 running in manual operation mode (4904) | 1.3.6.1.4.1.318.1.1.13.5.3.12.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating2Type OBJECT-TYPE Electric heater #2 type (4908) | 1.3.6.1.4.1.318.1.1.13.5.3.12.9 | INTEGER {direct(1), pwm(2)} | read-only | mandatory |
| airIRmPmEheating2StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.12.10 | |||
| airIRmPmEheating2StartTemperatureK OBJECT-TYPE Electric heater #2 start temperature in tenths of Kelvins (4909) | 1.3.6.1.4.1.318.1.1.13.5.3.12.10.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating2StartTemperatureF OBJECT-TYPE Electric heater #2 start temperature in tenths of degrees Fahrenheit (4909) | 1.3.6.1.4.1.318.1.1.13.5.3.12.10.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating2Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.12.11 | |||
| airIRmPmEheating2HysteresisK OBJECT-TYPE Electric heater #2 hysteresis in tenths of Kelvins (4910) | 1.3.6.1.4.1.318.1.1.13.5.3.12.11.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating2HysteresisF OBJECT-TYPE Electric heater #2 hysteresis in tenths of degrees Fahrenheit (4910) | 1.3.6.1.4.1.318.1.1.13.5.3.12.11.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating2Runtime OBJECT-TYPE Electric heater #2 runtime in hours (4916) | 1.3.6.1.4.1.318.1.1.13.5.3.12.17 | INTEGER | read-only | mandatory |
| airIRmPmEheating3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.13 | |||
| airIRmPmEheating3ManOpEnable OBJECT-TYPE Electric heater #3 manual operation enable (5001) | 1.3.6.1.4.1.318.1.1.13.5.3.13.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating3Running OBJECT-TYPE Electric heater #3 running state (5003) | 1.3.6.1.4.1.318.1.1.13.5.3.13.4 | AirIRmControlState | read-only | mandatory |
| airIRmPmEheating3ManOpRunning OBJECT-TYPE Electric heater #3 running in manual operation mode (5004) | 1.3.6.1.4.1.318.1.1.13.5.3.13.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating3Type OBJECT-TYPE Electric heater #3 type (5008) | 1.3.6.1.4.1.318.1.1.13.5.3.13.9 | INTEGER {direct(1), pwm(2)} | read-only | mandatory |
| airIRmPmEheating3StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.13.10 | |||
| airIRmPmEheating3StartTemperatureK OBJECT-TYPE Electric heater #3 start temperature in tenths of Kelvins (5009) | 1.3.6.1.4.1.318.1.1.13.5.3.13.10.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating3StartTemperatureF OBJECT-TYPE Electric heater #3 start temperature in tenths of degrees Fahrenheit (5009) | 1.3.6.1.4.1.318.1.1.13.5.3.13.10.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating3Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.13.11 | |||
| airIRmPmEheating3HysteresisK OBJECT-TYPE Electric heater #3 hysteresis in tenths of Kelvins (5010) | 1.3.6.1.4.1.318.1.1.13.5.3.13.11.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating3HysteresisF OBJECT-TYPE Electric heater #3 hysteresis in tenths of degrees Fahrenheit (5010) | 1.3.6.1.4.1.318.1.1.13.5.3.13.11.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating3Runtime OBJECT-TYPE Electric heater #3 runtime in hours (5016) | 1.3.6.1.4.1.318.1.1.13.5.3.13.17 | INTEGER | read-only | mandatory |
| airIRmPmEheating4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.14 | |||
| airIRmPmEheating4ManOpEnable OBJECT-TYPE Electric heater #4 manual operation enable (5101) | 1.3.6.1.4.1.318.1.1.13.5.3.14.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating4Running OBJECT-TYPE Electric heater #4 running state (5103) | 1.3.6.1.4.1.318.1.1.13.5.3.14.4 | AirIRmControlState | read-only | mandatory |
| airIRmPmEheating4ManOpRunning OBJECT-TYPE Electric heater #4 running in manual operation mode (5104) | 1.3.6.1.4.1.318.1.1.13.5.3.14.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmEheating4Type OBJECT-TYPE Electric heater #4 type (5108) | 1.3.6.1.4.1.318.1.1.13.5.3.14.9 | INTEGER {direct(1), pwm(2)} | read-only | mandatory |
| airIRmPmEheating4StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.14.10 | |||
| airIRmPmEheating4StartTemperatureK OBJECT-TYPE Electric heater #4 start temperature in tenths of Kelvins (5109) | 1.3.6.1.4.1.318.1.1.13.5.3.14.10.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating4StartTemperatureF OBJECT-TYPE Electric heater #4 start temperature in tenths of degrees Fahrenheit (5109) | 1.3.6.1.4.1.318.1.1.13.5.3.14.10.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating4Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.14.11 | |||
| airIRmPmEheating4HysteresisK OBJECT-TYPE Electric heater #4 hysteresis in tenths of Kelvins (5110) | 1.3.6.1.4.1.318.1.1.13.5.3.14.11.1 | INTEGER | read-write | mandatory |
| airIRmPmEheating4HysteresisF OBJECT-TYPE Electric heater #4 hysteresis in tenths of degrees Fahrenheit (5110) | 1.3.6.1.4.1.318.1.1.13.5.3.14.11.2 | INTEGER | read-write | mandatory |
| airIRmPmEheating4Runtime OBJECT-TYPE Electric heater #4 runtime in hours (5116) | 1.3.6.1.4.1.318.1.1.13.5.3.14.17 | INTEGER | read-only | mandatory |
| airIRmPmGECWvalve OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.15 | |||
| airIRmPmGECWvalveManOpEnable OBJECT-TYPE GE/CW valve manual operation enable (5201) | 1.3.6.1.4.1.318.1.1.13.5.3.15.2 | INTEGER | read-only | mandatory |
| airIRmPmGECWvalveStartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.15.9 | |||
| airIRmPmGECWvalveStartTemperatureK OBJECT-TYPE GE/CW valve start temperature in tenths of Kelvins (5208) | 1.3.6.1.4.1.318.1.1.13.5.3.15.9.1 | INTEGER | read-write | mandatory |
| airIRmPmGECWvalveStartTemperatureF OBJECT-TYPE GE/CW valve start temperature in tenths of degrees Fahrenheit (5208) | 1.3.6.1.4.1.318.1.1.13.5.3.15.9.2 | INTEGER | read-write | mandatory |
| airIRmPmGECWvalveLinearRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.15.10 | |||
| airIRmPmGECWvalveLinearRangeK OBJECT-TYPE GE/CW valve linear range in tenths of Kelvins (5209) | 1.3.6.1.4.1.318.1.1.13.5.3.15.10.1 | INTEGER | read-write | mandatory |
| airIRmPmGECWvalveLinearRangeF OBJECT-TYPE GE/CW valve linear range in tenths of degrees Fahrenheit (5209) | 1.3.6.1.4.1.318.1.1.13.5.3.15.10.2 | INTEGER | read-write | mandatory |
| airIRmPmGECWvalveGEOffTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.15.12 | |||
| airIRmPmGECWvalveGEOffTempC OBJECT-TYPE GE/CW valve GE off temperature in tenths of degrees Celsius (5211) | 1.3.6.1.4.1.318.1.1.13.5.3.15.12.1 | INTEGER | read-write | mandatory |
| airIRmPmGECWvalveGEOffTempF OBJECT-TYPE GE/CW valve GE off temperature in tenths of degrees Fahrenheit (5211) | 1.3.6.1.4.1.318.1.1.13.5.3.15.12.2 | INTEGER | read-write | mandatory |
| airIRmPmGECWvalveOpeningGrade OBJECT-TYPE GE/CW valve opening grade in percent (5214) | 1.3.6.1.4.1.318.1.1.13.5.3.15.15 | INTEGER | read-only | mandatory |
| airIRmPmGECWvalveManOpOpeningGrade OBJECT-TYPE GE/CW valve manual operation opening grade in percent (5215) | 1.3.6.1.4.1.318.1.1.13.5.3.15.16 | INTEGER | read-only | mandatory |
| airIRmPmGvalve OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.16 | |||
| airIRmPmGvalveManOperationEnable OBJECT-TYPE G-valve manual operation enable (5301) | 1.3.6.1.4.1.318.1.1.13.5.3.16.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmGvalvePreOpeningTime OBJECT-TYPE G-valve pre-opening time in seconds (5310) | 1.3.6.1.4.1.318.1.1.13.5.3.16.11 | INTEGER | read-only | mandatory |
| airIRmPmGvalvePreOpeningGrade OBJECT-TYPE G-valve pre-opening grade in percent (5311) | 1.3.6.1.4.1.318.1.1.13.5.3.16.12 | INTEGER | read-only | mandatory |
| airIRmPmGvalveOpeningGrade OBJECT-TYPE G-valve opening grade in percent (5312) | 1.3.6.1.4.1.318.1.1.13.5.3.16.13 | INTEGER | read-only | mandatory |
| airIRmPmGvalveManOpOpeningGrade OBJECT-TYPE G-valve manual operation opening grade in percent (5313) | 1.3.6.1.4.1.318.1.1.13.5.3.16.14 | INTEGER | read-only | mandatory |
| airIRmPmDrycooler1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.17 | |||
| airIRmPmDrycooler1ManOpEnable OBJECT-TYPE Drycooler 1 manual operation enable setting (5401) | 1.3.6.1.4.1.318.1.1.13.5.3.17.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler1Running OBJECT-TYPE Drycooler 1 running (5402) | 1.3.6.1.4.1.318.1.1.13.5.3.17.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler1ManOpRunning OBJECT-TYPE Drycooler 1 manual operation running (5404) | 1.3.6.1.4.1.318.1.1.13.5.3.17.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler1WinterStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.17.9 | |||
| airIRmPmDrycooler1WinterStartTempC OBJECT-TYPE Drycooler 1 winter mode start temperature in tenths of degrees Celsius (5408) | 1.3.6.1.4.1.318.1.1.13.5.3.17.9.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler1WinterStartTempF OBJECT-TYPE Drycooler 1 winter mode start temperature in tenths of degrees Fahrenheit (5408) | 1.3.6.1.4.1.318.1.1.13.5.3.17.9.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler1SummerStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.17.10 | |||
| airIRmPmDrycooler1SummerStartTempC OBJECT-TYPE Drycooler 1 summer mode start temperature in tenths of degrees Celsius (5409) | 1.3.6.1.4.1.318.1.1.13.5.3.17.10.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler1SummerStartTempF OBJECT-TYPE Drycooler 1 summer mode start temperature in tenths of degrees Fahrenheit (5409) | 1.3.6.1.4.1.318.1.1.13.5.3.17.10.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler1Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.17.11 | |||
| airIRmPmDrycooler1HysteresisK OBJECT-TYPE Drycooler 1 hysteresis in tenths of Kelvins (5410) | 1.3.6.1.4.1.318.1.1.13.5.3.17.11.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler1HysteresisF OBJECT-TYPE Drycooler 1 hysteresis in tenths of degrees Fahrenheit (5410) | 1.3.6.1.4.1.318.1.1.13.5.3.17.11.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler1Runtime OBJECT-TYPE Drycooler 1 runtime in hours (5415) | 1.3.6.1.4.1.318.1.1.13.5.3.17.16 | INTEGER | read-only | mandatory |
| airIRmPmDrycooler2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.18 | |||
| airIRmPmDrycooler2ManOpEnable OBJECT-TYPE Drycooler 2 manual operation enable setting (5501) | 1.3.6.1.4.1.318.1.1.13.5.3.18.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler2Running OBJECT-TYPE Drycooler 2 running (5502) | 1.3.6.1.4.1.318.1.1.13.5.3.18.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler2ManOpRunning OBJECT-TYPE Drycooler 2 manual operation running (5504) | 1.3.6.1.4.1.318.1.1.13.5.3.18.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler2WinterStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.18.9 | |||
| airIRmPmDrycooler2WinterStartTempC OBJECT-TYPE Drycooler 2 winter mode start temperature in tenths of degrees Celsius (5508) | 1.3.6.1.4.1.318.1.1.13.5.3.18.9.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler2WinterStartTempF OBJECT-TYPE Drycooler 2 winter mode start temperature in tenths of degrees Fahrenheit (5508) | 1.3.6.1.4.1.318.1.1.13.5.3.18.9.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler2SummerStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.18.10 | |||
| airIRmPmDrycooler2SummerStartTempC OBJECT-TYPE Drycooler 2 summer mode start temperature in tenths of degrees Celsius (5509) | 1.3.6.1.4.1.318.1.1.13.5.3.18.10.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler2SummerStartTempF OBJECT-TYPE Drycooler 2 summer mode start temperature in tenths of degrees Fahrenheit (5509) | 1.3.6.1.4.1.318.1.1.13.5.3.18.10.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler2Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.18.11 | |||
| airIRmPmDrycooler2HysteresisK OBJECT-TYPE Drycooler 2 hysteresis in tenths of Kelvins (5510) | 1.3.6.1.4.1.318.1.1.13.5.3.18.11.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler2HysteresisF OBJECT-TYPE Drycooler 2 hysteresis in tenths of degrees Fahrenheit (5510) | 1.3.6.1.4.1.318.1.1.13.5.3.18.11.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler2Runtime OBJECT-TYPE Drycooler 2 runtime in hours (5515) | 1.3.6.1.4.1.318.1.1.13.5.3.18.16 | INTEGER | read-only | mandatory |
| airIRmPmDrycooler3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.19 | |||
| airIRmPmDrycooler3ManOpEnable OBJECT-TYPE Drycooler 3 manual operation enable setting (5601) | 1.3.6.1.4.1.318.1.1.13.5.3.19.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler3Running OBJECT-TYPE Drycooler 3 running (5602) | 1.3.6.1.4.1.318.1.1.13.5.3.19.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler3ManOpRunning OBJECT-TYPE Drycooler 3 manual operation running (5604) | 1.3.6.1.4.1.318.1.1.13.5.3.19.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler3WinterStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.19.9 | |||
| airIRmPmDrycooler3WinterStartTempC OBJECT-TYPE Drycooler 3 winter mode start temperature in tenths of degrees Celsius (5608) | 1.3.6.1.4.1.318.1.1.13.5.3.19.9.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler3WinterStartTempF OBJECT-TYPE Drycooler 3 winter mode start temperature in tenths of degrees Fahrenheit (5608) | 1.3.6.1.4.1.318.1.1.13.5.3.19.9.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler3SummerStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.19.10 | |||
| airIRmPmDrycooler3SummerStartTempC OBJECT-TYPE Drycooler 3 summer mode start temperature in tenths of degrees Celsius (5609) | 1.3.6.1.4.1.318.1.1.13.5.3.19.10.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler3SummerStartTempF OBJECT-TYPE Drycooler 3 summer mode start temperature in tenths of degrees Fahrenheit (5609) | 1.3.6.1.4.1.318.1.1.13.5.3.19.10.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler3Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.19.11 | |||
| airIRmPmDrycooler3HysteresisK OBJECT-TYPE Drycooler 3 hysteresis in tenths of Kelvins (5610) | 1.3.6.1.4.1.318.1.1.13.5.3.19.11.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler3HysteresisF OBJECT-TYPE Drycooler 3 hysteresis in tenths of degrees Fahrenheit (5610) | 1.3.6.1.4.1.318.1.1.13.5.3.19.11.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler3Runtime OBJECT-TYPE Drycooler 3 runtime in hours (5615) | 1.3.6.1.4.1.318.1.1.13.5.3.19.16 | INTEGER | read-only | mandatory |
| airIRmPmDrycooler4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.20 | |||
| airIRmPmDrycooler4ManOpEnable OBJECT-TYPE Drycooler 4 manual operation enable setting (5701) | 1.3.6.1.4.1.318.1.1.13.5.3.20.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler4Running OBJECT-TYPE Drycooler 4 running (5702) | 1.3.6.1.4.1.318.1.1.13.5.3.20.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler4ManOpRunning OBJECT-TYPE Drycooler 4 manual operation running (5704) | 1.3.6.1.4.1.318.1.1.13.5.3.20.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDrycooler4WinterStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.20.9 | |||
| airIRmPmDrycooler4WinterStartTempC OBJECT-TYPE Drycooler 4 winter mode start temperature in tenths of degrees Celsius (5708) | 1.3.6.1.4.1.318.1.1.13.5.3.20.9.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler4WinterStartTempF OBJECT-TYPE Drycooler 4 winter mode start temperature in tenths of degrees Fahrenheit (5708) | 1.3.6.1.4.1.318.1.1.13.5.3.20.9.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler4SummerStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.20.10 | |||
| airIRmPmDrycooler4SummerStartTempC OBJECT-TYPE Drycooler 4 summer mode start temperature in tenths of degrees Celsius (5709) | 1.3.6.1.4.1.318.1.1.13.5.3.20.10.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler4SummerStartTempF OBJECT-TYPE Drycooler 4 summer mode start temperature in tenths of degrees Fahrenheit (5709) | 1.3.6.1.4.1.318.1.1.13.5.3.20.10.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler4Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.20.11 | |||
| airIRmPmDrycooler4HysteresisK OBJECT-TYPE Drycooler 4 hysteresis in tenths of Kelvins (5710) | 1.3.6.1.4.1.318.1.1.13.5.3.20.11.1 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler4HysteresisF OBJECT-TYPE Drycooler 4 hysteresis in tenths of degrees Fahrenheit (5710) | 1.3.6.1.4.1.318.1.1.13.5.3.20.11.2 | INTEGER | read-write | mandatory |
| airIRmPmDrycooler4Runtime OBJECT-TYPE Drycooler 4 runtime in hours (5715) | 1.3.6.1.4.1.318.1.1.13.5.3.20.16 | INTEGER | read-only | mandatory |
| airIRmPmPump1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.21 | |||
| airIRmPmPump1ManOpEnable OBJECT-TYPE Pump 1 manual operation enable state (5801) | 1.3.6.1.4.1.318.1.1.13.5.3.21.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump1Running OBJECT-TYPE Pump 1 running (5802) | 1.3.6.1.4.1.318.1.1.13.5.3.21.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump1ManOpRunning OBJECT-TYPE Pump 1 manual operation running (5805) | 1.3.6.1.4.1.318.1.1.13.5.3.21.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump1StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.21.10 | |||
| airIRmPmPump1StartTemperatureK OBJECT-TYPE Pump 1 starting temperature in tenths of Kelvins (5809) | 1.3.6.1.4.1.318.1.1.13.5.3.21.10.1 | INTEGER | read-write | mandatory |
| airIRmPmPump1StartTemperatureF OBJECT-TYPE Pump 1 starting temperature in tenths of degrees Fahrenheit (5809) | 1.3.6.1.4.1.318.1.1.13.5.3.21.10.2 | INTEGER | read-write | mandatory |
| airIRmPmPump1Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.21.11 | |||
| airIRmPmPump1HysteresisK OBJECT-TYPE Pump 1 hysteresis in tenths of Kelvins (5810) | 1.3.6.1.4.1.318.1.1.13.5.3.21.11.1 | INTEGER | read-write | mandatory |
| airIRmPmPump1HysteresisF OBJECT-TYPE Pump 1 hysteresis in tenths of degrees Fahrenheit (5810) | 1.3.6.1.4.1.318.1.1.13.5.3.21.11.2 | INTEGER | read-write | mandatory |
| airIRmPmPump1LinearRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.21.12 | |||
| airIRmPmPump1LinearRangeK OBJECT-TYPE Pump 1 linear range in tenths of Kelvins (5811) | 1.3.6.1.4.1.318.1.1.13.5.3.21.12.1 | INTEGER | read-write | mandatory |
| airIRmPmPump1LinearRangeF OBJECT-TYPE Pump 1 linear range in tenths of degrees Fahrenheit (5811) | 1.3.6.1.4.1.318.1.1.13.5.3.21.12.2 | INTEGER | read-write | mandatory |
| airIRmPmPump1PressureSetpoint OBJECT-TYPE Pump 1 pressure setpoint in tenths of Bars (5812) | 1.3.6.1.4.1.318.1.1.13.5.3.21.13 | INTEGER | read-write | mandatory |
| airIRmPmPump1Runtime OBJECT-TYPE Pump 1 runtime in hours (5820) | 1.3.6.1.4.1.318.1.1.13.5.3.21.21 | INTEGER | read-only | mandatory |
| airIRmPmPump1Speed OBJECT-TYPE Pump 1 speed in percent (5821) | 1.3.6.1.4.1.318.1.1.13.5.3.21.22 | INTEGER | read-only | mandatory |
| airIRmPmPump1ControlCycle OBJECT-TYPE Pump 1 control cycle length in seconds (5827) | 1.3.6.1.4.1.318.1.1.13.5.3.21.28 | INTEGER | read-write | mandatory |
| airIRmPmPump1MaxAdjust OBJECT-TYPE Pump 1 maximum adjustment in percent (5828) | 1.3.6.1.4.1.318.1.1.13.5.3.21.29 | INTEGER | read-write | mandatory |
| airIRmPmPump1ControlFactor OBJECT-TYPE Pump 1 control factor setting (5829) | 1.3.6.1.4.1.318.1.1.13.5.3.21.30 | INTEGER | read-write | mandatory |
| airIRmPmPump2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.22 | |||
| airIRmPmPump2ManOpEnable OBJECT-TYPE Pump 2 manual operation enable state (5901) | 1.3.6.1.4.1.318.1.1.13.5.3.22.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump2Running OBJECT-TYPE Pump 2 running (5902) | 1.3.6.1.4.1.318.1.1.13.5.3.22.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump2ManOpRunning OBJECT-TYPE Pump 2 manual operation running (5905) | 1.3.6.1.4.1.318.1.1.13.5.3.22.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump2StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.22.10 | |||
| airIRmPmPump2StartTemperatureK OBJECT-TYPE Pump 2 starting temperature in tenths of Kelvins (5909) | 1.3.6.1.4.1.318.1.1.13.5.3.22.10.1 | INTEGER | read-write | mandatory |
| airIRmPmPump2StartTemperatureF OBJECT-TYPE Pump 2 starting temperature in tenths of degrees Fahrenheit (5909) | 1.3.6.1.4.1.318.1.1.13.5.3.22.10.2 | INTEGER | read-write | mandatory |
| airIRmPmPump2Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.22.11 | |||
| airIRmPmPump2HysteresisK OBJECT-TYPE Pump 2 hysteresis in tenths of Kelvins (5910) | 1.3.6.1.4.1.318.1.1.13.5.3.22.11.1 | INTEGER | read-write | mandatory |
| airIRmPmPump2HysteresisF OBJECT-TYPE Pump 2 hysteresis in tenths of degrees Fahrenheit (5910) | 1.3.6.1.4.1.318.1.1.13.5.3.22.11.2 | INTEGER | read-write | mandatory |
| airIRmPmPump2LinearRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.22.12 | |||
| airIRmPmPump2LinearRangeK OBJECT-TYPE Pump 2 linear range in tenths of Kelvins (5911) | 1.3.6.1.4.1.318.1.1.13.5.3.22.12.1 | INTEGER | read-write | mandatory |
| airIRmPmPump2LinearRangeF OBJECT-TYPE Pump 2 linear range in tenths of degrees Fahrenheit (5911) | 1.3.6.1.4.1.318.1.1.13.5.3.22.12.2 | INTEGER | read-write | mandatory |
| airIRmPmPump2PressureSetpoint OBJECT-TYPE Pump 2 pressure setpoint in tenths of Bars (5912) | 1.3.6.1.4.1.318.1.1.13.5.3.22.13 | INTEGER | read-write | mandatory |
| airIRmPmPump2Runtime OBJECT-TYPE Pump 2 runtime in hours (5920) | 1.3.6.1.4.1.318.1.1.13.5.3.22.21 | INTEGER | read-only | mandatory |
| airIRmPmPump2Speed OBJECT-TYPE Pump 2 speed in percent (5921) | 1.3.6.1.4.1.318.1.1.13.5.3.22.22 | INTEGER | read-only | mandatory |
| airIRmPmPump2ControlCycle OBJECT-TYPE Pump 2 control cycle length in seconds (5927) | 1.3.6.1.4.1.318.1.1.13.5.3.22.28 | INTEGER | read-write | mandatory |
| airIRmPmPump2MaxAdjust OBJECT-TYPE Pump 2 maximum adjustment in percent (5928) | 1.3.6.1.4.1.318.1.1.13.5.3.22.29 | INTEGER | read-write | mandatory |
| airIRmPmPump2ControlFactor OBJECT-TYPE Pump 2 control factor setting (5929) | 1.3.6.1.4.1.318.1.1.13.5.3.22.30 | INTEGER | read-write | mandatory |
| airIRmPmPump3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.23 | |||
| airIRmPmPump3ManOpEnable OBJECT-TYPE Pump 3 manual operation enable state (6001) | 1.3.6.1.4.1.318.1.1.13.5.3.23.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump3Running OBJECT-TYPE Pump 3 running (6002) | 1.3.6.1.4.1.318.1.1.13.5.3.23.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump3ManOpRunning OBJECT-TYPE Pump 3 manual operation running (6005) | 1.3.6.1.4.1.318.1.1.13.5.3.23.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump3StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.23.10 | |||
| airIRmPmPump3StartTemperatureK OBJECT-TYPE Pump 3 starting temperature in tenths of Kelvins (6009) | 1.3.6.1.4.1.318.1.1.13.5.3.23.10.1 | INTEGER | read-write | mandatory |
| airIRmPmPump3StartTemperatureF OBJECT-TYPE Pump 3 starting temperature in tenths of degrees Fahrenheit (6009) | 1.3.6.1.4.1.318.1.1.13.5.3.23.10.2 | INTEGER | read-write | mandatory |
| airIRmPmPump3Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.23.11 | |||
| airIRmPmPump3HysteresisK OBJECT-TYPE Pump 3 hysteresis in tenths of Kelvins (6010) | 1.3.6.1.4.1.318.1.1.13.5.3.23.11.1 | INTEGER | read-write | mandatory |
| airIRmPmPump3HysteresisF OBJECT-TYPE Pump 3 hysteresis in tenths of degrees Fahrenheit (6010) | 1.3.6.1.4.1.318.1.1.13.5.3.23.11.2 | INTEGER | read-write | mandatory |
| airIRmPmPump3LinearRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.23.12 | |||
| airIRmPmPump3LinearRangeK OBJECT-TYPE Pump 3 linear range in tenths of Kelvins (6011) | 1.3.6.1.4.1.318.1.1.13.5.3.23.12.1 | INTEGER | read-write | mandatory |
| airIRmPmPump3LinearRangeF OBJECT-TYPE Pump 3 linear range in tenths of degrees Fahrenheit (6011) | 1.3.6.1.4.1.318.1.1.13.5.3.23.12.2 | INTEGER | read-write | mandatory |
| airIRmPmPump3PressureSetpoint OBJECT-TYPE Pump 3 pressure setpoint in tenths of Bars (6012) | 1.3.6.1.4.1.318.1.1.13.5.3.23.13 | INTEGER | read-write | mandatory |
| airIRmPmPump3Runtime OBJECT-TYPE Pump 3 runtime in hours (6020) | 1.3.6.1.4.1.318.1.1.13.5.3.23.21 | INTEGER | read-only | mandatory |
| airIRmPmPump3Speed OBJECT-TYPE Pump 3 speed in percent (6021) | 1.3.6.1.4.1.318.1.1.13.5.3.23.22 | INTEGER | read-only | mandatory |
| airIRmPmPump3ControlCycle OBJECT-TYPE Pump 3 control cycle length in seconds (6027) | 1.3.6.1.4.1.318.1.1.13.5.3.23.28 | INTEGER | read-write | mandatory |
| airIRmPmPump3MaxAdjust OBJECT-TYPE Pump 3 maximum adjustment in percent (6028) | 1.3.6.1.4.1.318.1.1.13.5.3.23.29 | INTEGER | read-write | mandatory |
| airIRmPmPump3ControlFactor OBJECT-TYPE Pump 3 control factor setting (6029) | 1.3.6.1.4.1.318.1.1.13.5.3.23.30 | INTEGER | read-write | mandatory |
| airIRmPmPump4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.24 | |||
| airIRmPmPump4ManOpEnable OBJECT-TYPE Pump 4 manual operation enable state (6101) | 1.3.6.1.4.1.318.1.1.13.5.3.24.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump4Running OBJECT-TYPE Pump 4 running (6102) | 1.3.6.1.4.1.318.1.1.13.5.3.24.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump4ManOpRunning OBJECT-TYPE Pump 4 manual operation running (6105) | 1.3.6.1.4.1.318.1.1.13.5.3.24.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPump4StartTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.24.10 | |||
| airIRmPmPump4StartTemperatureK OBJECT-TYPE Pump 4 starting temperature in tenths of Kelvins (6109) | 1.3.6.1.4.1.318.1.1.13.5.3.24.10.1 | INTEGER | read-write | mandatory |
| airIRmPmPump4StartTemperatureF OBJECT-TYPE Pump 4 starting temperature in tenths of degrees Fahrenheit (6109) | 1.3.6.1.4.1.318.1.1.13.5.3.24.10.2 | INTEGER | read-write | mandatory |
| airIRmPmPump4Hysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.24.11 | |||
| airIRmPmPump4HysteresisK OBJECT-TYPE Pump 4 hysteresis in tenths of Kelvins (6110) | 1.3.6.1.4.1.318.1.1.13.5.3.24.11.1 | INTEGER | read-write | mandatory |
| airIRmPmPump4HysteresisF OBJECT-TYPE Pump 4 hysteresis in tenths of degrees Fahrenheit (6110) | 1.3.6.1.4.1.318.1.1.13.5.3.24.11.2 | INTEGER | read-write | mandatory |
| airIRmPmPump4LinearRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.24.12 | |||
| airIRmPmPump4LinearRangeK OBJECT-TYPE Pump 4 linear range in tenths of Kelvins (6111) | 1.3.6.1.4.1.318.1.1.13.5.3.24.12.1 | INTEGER | read-write | mandatory |
| airIRmPmPump4LinearRangeF OBJECT-TYPE Pump 4 linear range in tenths of degrees Fahrenheit (6111) | 1.3.6.1.4.1.318.1.1.13.5.3.24.12.2 | INTEGER | read-write | mandatory |
| airIRmPmPump4PressureSetpoint OBJECT-TYPE Pump 4 pressure setpoint in tenths of Bars (6112) | 1.3.6.1.4.1.318.1.1.13.5.3.24.13 | INTEGER | read-write | mandatory |
| airIRmPmPump4Runtime OBJECT-TYPE Pump 4 runtime in hours (6120) | 1.3.6.1.4.1.318.1.1.13.5.3.24.21 | INTEGER | read-only | mandatory |
| airIRmPmPump4Speed OBJECT-TYPE Pump 4 speed in percent (6121) | 1.3.6.1.4.1.318.1.1.13.5.3.24.22 | INTEGER | read-only | mandatory |
| airIRmPmPump4ControlCycle OBJECT-TYPE Pump 4 control cycle length in seconds (6127) | 1.3.6.1.4.1.318.1.1.13.5.3.24.28 | INTEGER | read-write | mandatory |
| airIRmPmPump4MaxAdjust OBJECT-TYPE Pump 4 maximum adjustment in percent (6128) | 1.3.6.1.4.1.318.1.1.13.5.3.24.29 | INTEGER | read-write | mandatory |
| airIRmPmPump4ControlFactor OBJECT-TYPE Pump 4 control factor setting (6129) | 1.3.6.1.4.1.318.1.1.13.5.3.24.30 | INTEGER | read-write | mandatory |
| airIRmPmHotgasHeating OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.25 | |||
| airIRmPmHotgasHeatRunning OBJECT-TYPE Hotgas heat running state. (6202) | 1.3.6.1.4.1.318.1.1.13.5.3.25.3 | AirIRmControlState | read-only | mandatory |
| airIRmPmPWWHeating OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.26 | |||
| airIRmPmPWWHeatingManOpEnable OBJECT-TYPE PWW-heating manual operation enable (6301) | 1.3.6.1.4.1.318.1.1.13.5.3.26.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPWWHeatingRunning OBJECT-TYPE PWW-heating running (6302) | 1.3.6.1.4.1.318.1.1.13.5.3.26.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPWWHeatingManOpRunning OBJECT-TYPE PWW-heating manual operation running (6303) | 1.3.6.1.4.1.318.1.1.13.5.3.26.4 | AirIRmActivityState | read-only | mandatory |
| airIRmPmPWWHeatingType OBJECT-TYPE PWW-heating type (6308) | 1.3.6.1.4.1.318.1.1.13.5.3.26.9 | INTEGER {direct(1), undefined(2)} | read-only | mandatory |
| airIRmPmPWWHeatingStartTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.26.10 | |||
| airIRmPmPWWHeatingStartTempK OBJECT-TYPE PWW-heating starting temperature in Kelvins (6309) | 1.3.6.1.4.1.318.1.1.13.5.3.26.10.1 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingStartTempF OBJECT-TYPE PWW-heating starting temperature in degrees Fahrenheit (6309) | 1.3.6.1.4.1.318.1.1.13.5.3.26.10.2 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingHysteresis OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.26.12 | |||
| airIRmPmPWWHeatingHysteresisK OBJECT-TYPE PWW-heating hysteresis in Kelvins (6311) | 1.3.6.1.4.1.318.1.1.13.5.3.26.12.1 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingHysteresisF OBJECT-TYPE PWW-heating hysteresis in degrees Fahrenheit (6311) | 1.3.6.1.4.1.318.1.1.13.5.3.26.12.2 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingLinearRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.26.13 | |||
| airIRmPmPWWHeatingLinearRangeK OBJECT-TYPE PWW-heating linear range in Kelvins (6312) | 1.3.6.1.4.1.318.1.1.13.5.3.26.13.1 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingLinearRangeF OBJECT-TYPE PWW-heating linear range in degrees Fahrenheit (6312) | 1.3.6.1.4.1.318.1.1.13.5.3.26.13.2 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingCurrentValue OBJECT-TYPE PWW-heating current value in percent (6315) | 1.3.6.1.4.1.318.1.1.13.5.3.26.16 | INTEGER | read-write | mandatory |
| airIRmPmPWWHeatingManOpValue OBJECT-TYPE PWW-heating manual operation value in percent (6316) | 1.3.6.1.4.1.318.1.1.13.5.3.26.17 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.27 | |||
| airIRmPmHumidifier1ManOpEnable OBJECT-TYPE Humidifier #1 manual operation enable (6401) | 1.3.6.1.4.1.318.1.1.13.5.3.27.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmHumidifier1Running OBJECT-TYPE Humidifier #1 running state (6402) | 1.3.6.1.4.1.318.1.1.13.5.3.27.3 | AirIRmControlState | read-only | mandatory |
| airIRmPmHumidifier1ManOpRunning OBJECT-TYPE Humidifier #1 manual operation running state (6404) | 1.3.6.1.4.1.318.1.1.13.5.3.27.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmHumidifier1Type OBJECT-TYPE Humidifier #1 type (6416) | 1.3.6.1.4.1.318.1.1.13.5.3.27.17 | INTEGER {direct(1), proportional(2)} | read-only | mandatory |
| airIRmPmHumidifier1StartHumidity OBJECT-TYPE Humidifier #1 start humidity in tenths of percent relative humidity (6417) | 1.3.6.1.4.1.318.1.1.13.5.3.27.18 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier1Hysteresis OBJECT-TYPE Humidifier #1 hysteresis in tenths of percent relative humidity (6419) | 1.3.6.1.4.1.318.1.1.13.5.3.27.20 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier1LinearRange OBJECT-TYPE Humidifier #1 linear range in tenths of percent relative humidity per Kelvin (6420) | 1.3.6.1.4.1.318.1.1.13.5.3.27.21 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier1Runtime OBJECT-TYPE Humidifier #1 runtime in hours (6426) | 1.3.6.1.4.1.318.1.1.13.5.3.27.27 | INTEGER | read-only | mandatory |
| airIRmPmHumidifier1CurrentValue OBJECT-TYPE Humidifier #1 current value in percent (6427) | 1.3.6.1.4.1.318.1.1.13.5.3.27.28 | INTEGER | read-only | mandatory |
| airIRmPmHumidifier1ManOpValue OBJECT-TYPE Humidifier #1 manual operation value in percent (6428) | 1.3.6.1.4.1.318.1.1.13.5.3.27.29 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.28 | |||
| airIRmPmHumidifier2ManOpEnable OBJECT-TYPE Humidifier #2 manual operation enable (6501) | 1.3.6.1.4.1.318.1.1.13.5.3.28.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmHumidifier2Running OBJECT-TYPE Humidifier #2 running state (6502) | 1.3.6.1.4.1.318.1.1.13.5.3.28.3 | AirIRmControlState | read-only | mandatory |
| airIRmPmHumidifier2ManOpRunning OBJECT-TYPE Humidifier #2 manual operation running state (6504) | 1.3.6.1.4.1.318.1.1.13.5.3.28.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmHumidifier2Type OBJECT-TYPE Humidifier #2 type (6516) | 1.3.6.1.4.1.318.1.1.13.5.3.28.17 | INTEGER {direct(1), proportional(2)} | read-only | mandatory |
| airIRmPmHumidifier2StartHumidity OBJECT-TYPE Humidifier #2 start humidity in tenths of percent relative humidity (6517) | 1.3.6.1.4.1.318.1.1.13.5.3.28.18 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier2Hysteresis OBJECT-TYPE Humidifier #2 hysteresis in tenths of percent relative humidity (6519) | 1.3.6.1.4.1.318.1.1.13.5.3.28.20 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier2LinearRange OBJECT-TYPE Humidifier #2 linear range in tenths of percent relative humidity per Kelvin (6520) | 1.3.6.1.4.1.318.1.1.13.5.3.28.21 | INTEGER | read-write | mandatory |
| airIRmPmHumidifier2Runtime OBJECT-TYPE Humidifier #2 runtime in hours (6526) | 1.3.6.1.4.1.318.1.1.13.5.3.28.27 | INTEGER | read-only | mandatory |
| airIRmPmHumidifier2CurrentValue OBJECT-TYPE Humidifier #2 current value in percent (6527) | 1.3.6.1.4.1.318.1.1.13.5.3.28.28 | INTEGER | read-only | mandatory |
| airIRmPmHumidifier2ManOpValue OBJECT-TYPE Humidifier #2 manual operation value in percent (6528) | 1.3.6.1.4.1.318.1.1.13.5.3.28.29 | INTEGER | read-write | mandatory |
| airIRmPmDehumidification OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.31 | |||
| airIRmPmDehumidificManOpEnable OBJECT-TYPE Dehumidifier manual operation enable setting (6801) | 1.3.6.1.4.1.318.1.1.13.5.3.31.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDehumidificRunning OBJECT-TYPE Dehumidifier running state (6802) | 1.3.6.1.4.1.318.1.1.13.5.3.31.3 | AirIRmControlState | read-only | mandatory |
| airIRmPmDehumidificManOpRunning OBJECT-TYPE Dehumidifier manual operation running (6804) | 1.3.6.1.4.1.318.1.1.13.5.3.31.5 | AirIRmActivityState | read-only | mandatory |
| airIRmPmDehumidificStartHumidity OBJECT-TYPE Dehumidifier start humidity in tenths of percent relative humidity (6809) | 1.3.6.1.4.1.318.1.1.13.5.3.31.10 | INTEGER | read-write | mandatory |
| airIRmPmDehumidificHysteresis OBJECT-TYPE Dehumidifier hysteresis in tenths of percent relative humidity (6811) | 1.3.6.1.4.1.318.1.1.13.5.3.31.12 | INTEGER | read-write | mandatory |
| airIRmPmDehumidificMinWaterTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.31.18 | |||
| airIRmPmDehumidificMinWaterTempC OBJECT-TYPE Dehumidifier minimum water temperature in tenths of degrees Celsius (6817) | 1.3.6.1.4.1.318.1.1.13.5.3.31.18.1 | INTEGER | read-write | mandatory |
| airIRmPmDehumidificMinWaterTempF OBJECT-TYPE Dehumidifier minimum water temperature in tenths of degrees Fahrenheit (6817) | 1.3.6.1.4.1.318.1.1.13.5.3.31.18.2 | INTEGER | read-write | mandatory |
| airIRmPmDehumidificMaxWaterTemp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.31.19 | |||
| airIRmPmDehumidificMaxWaterTempC OBJECT-TYPE Dehumidifier maximum water temperature in tenths of degrees Celsius (6818) | 1.3.6.1.4.1.318.1.1.13.5.3.31.19.1 | INTEGER | read-write | mandatory |
| airIRmPmDehumidificMaxWaterTempF OBJECT-TYPE Dehumidifier maximum water temperature in tenths of degrees Fahrenheit (6818) | 1.3.6.1.4.1.318.1.1.13.5.3.31.19.2 | INTEGER | read-write | mandatory |
| airIRmPmDehumidificRuntime OBJECT-TYPE Dehumidifier runtime in hours (6820) | 1.3.6.1.4.1.318.1.1.13.5.3.31.21 | INTEGER | read-write | mandatory |
| airIRmPmFan1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.32 | |||
| airIRmPmFan1ManOpEnable OBJECT-TYPE Fan 1 manual operation enable (6901) | 1.3.6.1.4.1.318.1.1.13.5.3.32.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan1Running OBJECT-TYPE Fan 1 running (6902) | 1.3.6.1.4.1.318.1.1.13.5.3.32.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan1ManOpRunning OBJECT-TYPE Fan 1 manual operation running (6905) | 1.3.6.1.4.1.318.1.1.13.5.3.32.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan1Type OBJECT-TYPE Fan 1 type (6908) | 1.3.6.1.4.1.318.1.1.13.5.3.32.9 | INTEGER {direct(1), proportional(2)} | read-only | mandatory |
| airIRmPmFan1Runtime OBJECT-TYPE Fan 1 runtime in hours (6931) | 1.3.6.1.4.1.318.1.1.13.5.3.32.32 | INTEGER | read-only | mandatory |
| airIRmPmFan1Speed OBJECT-TYPE Fan 1 speed in percent (6932) | 1.3.6.1.4.1.318.1.1.13.5.3.32.33 | INTEGER | read-only | mandatory |
| airIRmPmFan1ManOpSpeed OBJECT-TYPE Fan 1 manual operation speed in percent (6933) | 1.3.6.1.4.1.318.1.1.13.5.3.32.34 | INTEGER | read-only | mandatory |
| airIRmPmFan2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.33 | |||
| airIRmPmFan2ManOpEnable OBJECT-TYPE Fan 1 manual operation enable (7001) | 1.3.6.1.4.1.318.1.1.13.5.3.33.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan2Running OBJECT-TYPE Fan 1 running (7002) | 1.3.6.1.4.1.318.1.1.13.5.3.33.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan2ManOpRunning OBJECT-TYPE Fan 1 manual operation running (7005) | 1.3.6.1.4.1.318.1.1.13.5.3.33.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan2Type OBJECT-TYPE Fan 2 type (7008) | 1.3.6.1.4.1.318.1.1.13.5.3.33.9 | INTEGER {direct(1), proportional(2)} | read-only | mandatory |
| airIRmPmFan2Runtime OBJECT-TYPE Fan 1 runtime in hours (7031) | 1.3.6.1.4.1.318.1.1.13.5.3.33.32 | INTEGER | read-only | mandatory |
| airIRmPmFan2Speed OBJECT-TYPE Fan 1 speed in percent (7032) | 1.3.6.1.4.1.318.1.1.13.5.3.33.33 | INTEGER | read-only | mandatory |
| airIRmPmFan2ManOpSpeed OBJECT-TYPE Fan 1 manual operation speed in percent (7033) | 1.3.6.1.4.1.318.1.1.13.5.3.33.34 | INTEGER | read-only | mandatory |
| airIRmPmFan3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.34 | |||
| airIRmPmFan3ManOpEnable OBJECT-TYPE Fan 1 manual operation enable (7101) | 1.3.6.1.4.1.318.1.1.13.5.3.34.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan3Running OBJECT-TYPE Fan 1 running (7102) | 1.3.6.1.4.1.318.1.1.13.5.3.34.3 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan3ManOpRunning OBJECT-TYPE Fan 1 manual operation running (7105) | 1.3.6.1.4.1.318.1.1.13.5.3.34.6 | AirIRmActivityState | read-only | mandatory |
| airIRmPmFan3Type OBJECT-TYPE Fan 3 type (7108) | 1.3.6.1.4.1.318.1.1.13.5.3.34.9 | INTEGER {direct(1), proportional(2)} | read-only | mandatory |
| airIRmPmFan3Runtime OBJECT-TYPE Fan 1 runtime in hours (7131) | 1.3.6.1.4.1.318.1.1.13.5.3.34.32 | INTEGER | read-only | mandatory |
| airIRmPmFan3Speed OBJECT-TYPE Fan 1 speed in percent (7132) | 1.3.6.1.4.1.318.1.1.13.5.3.34.33 | INTEGER | read-only | mandatory |
| airIRmPmFan3ManOpSpeed OBJECT-TYPE Fan 1 manual operation speed in percent (7133) | 1.3.6.1.4.1.318.1.1.13.5.3.34.34 | INTEGER | read-only | mandatory |
| airIRmPmLouver1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.35 | |||
| airIRmPmLouver1ManOpEnable OBJECT-TYPE Louver 1 manual operation enable (7201) | 1.3.6.1.4.1.318.1.1.13.5.3.35.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmLouver1Position OBJECT-TYPE Louver 1 position (7202) | 1.3.6.1.4.1.318.1.1.13.5.3.35.3 | INTEGER {closed(1), open(2)} | read-only | mandatory |
| airIRmPmLouver1ManOpPosition OBJECT-TYPE Louver 1 manual operation position setting (7203) | 1.3.6.1.4.1.318.1.1.13.5.3.35.4 | INTEGER {closed(1), open(2)} | read-only | mandatory |
| airIRmPmLouver2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.36 | |||
| airIRmPmLouver2ManOpEnable OBJECT-TYPE Louver 2 manual operation enable (7301) | 1.3.6.1.4.1.318.1.1.13.5.3.36.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmLouver2Position OBJECT-TYPE Louver 2 position (7302) | 1.3.6.1.4.1.318.1.1.13.5.3.36.3 | INTEGER {closed(1), open(2)} | read-only | mandatory |
| airIRmPmLouver2ManOpPosition OBJECT-TYPE Louver 2 manual operation position setting (7303) | 1.3.6.1.4.1.318.1.1.13.5.3.36.4 | INTEGER {closed(1), open(2)} | read-only | mandatory |
| airIRmPmLouver3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.37 | |||
| airIRmPmLouver3ManOpEnable OBJECT-TYPE Louver 3 manual operation enable (7401) | 1.3.6.1.4.1.318.1.1.13.5.3.37.2 | AirIRmActivityState | read-only | mandatory |
| airIRmPmLouver3Position OBJECT-TYPE Louver 3 position (7402) | 1.3.6.1.4.1.318.1.1.13.5.3.37.3 | INTEGER {closed(1), open(2)} | read-only | mandatory |
| airIRmPmLouver3ManOpPosition OBJECT-TYPE Louver 3 manual operation position setting (7403) | 1.3.6.1.4.1.318.1.1.13.5.3.37.4 | INTEGER {closed(1), open(2)} | read-only | mandatory |
| airIRmPmAuxAlarm1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.38 | |||
| airIRmPmAuxAlarm2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.39 | |||
| airIRmPmAuxAlarm3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.40 | |||
| airIRmPmAuxAlarm4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.41 | |||
| airIRmPmAuxAlarm5 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.42 | |||
| airIRmPmAlarmBits OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.43 | |||
| airIRmPmFan1Failure OBJECT-TYPE Fan #1 failure (8500). | 1.3.6.1.4.1.318.1.1.13.5.3.43.1 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFan2Failure OBJECT-TYPE Fan #2 failure (8501). | 1.3.6.1.4.1.318.1.1.13.5.3.43.2 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFan3Failure OBJECT-TYPE Fan #3 failure (8502). | 1.3.6.1.4.1.318.1.1.13.5.3.43.3 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCompressor1Failure OBJECT-TYPE Compressor #1 failure (8503). | 1.3.6.1.4.1.318.1.1.13.5.3.43.4 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCompressor2Failure OBJECT-TYPE Compressor #2 failure (8504). | 1.3.6.1.4.1.318.1.1.13.5.3.43.5 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmWaterDetector OBJECT-TYPE Water detector alarm (8505). | 1.3.6.1.4.1.318.1.1.13.5.3.43.6 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmPhaseFailure OBJECT-TYPE Phase failure (8506). | 1.3.6.1.4.1.318.1.1.13.5.3.43.7 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFireSmokeDetector OBJECT-TYPE Fire/smoke detector (8507). | 1.3.6.1.4.1.318.1.1.13.5.3.43.8 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReturnAirTemperatureTooHigh OBJECT-TYPE Return air temperature too high (8508). | 1.3.6.1.4.1.318.1.1.13.5.3.43.9 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReturnAirHumidityTooHigh OBJECT-TYPE Return air humidity too high (8509). | 1.3.6.1.4.1.318.1.1.13.5.3.43.10 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSupplyAirTemperatureTooHigh OBJECT-TYPE Supply air temperature too high (8510). | 1.3.6.1.4.1.318.1.1.13.5.3.43.11 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSupplyAirHumidityTooHigh OBJECT-TYPE Supply air humidity too high (8511). | 1.3.6.1.4.1.318.1.1.13.5.3.43.12 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmWaterTemperatureTooHigh OBJECT-TYPE Water temperature too high (8512). | 1.3.6.1.4.1.318.1.1.13.5.3.43.13 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReturnAirTemperatureTooLow OBJECT-TYPE Return air temperature too low (8513). | 1.3.6.1.4.1.318.1.1.13.5.3.43.14 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReturnAirHumidityTooLow OBJECT-TYPE Return air humidity too low (8514). | 1.3.6.1.4.1.318.1.1.13.5.3.43.15 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSupplyAirTemperatureTooLow OBJECT-TYPE Supply air temperature too low (8515). | 1.3.6.1.4.1.318.1.1.13.5.3.43.16 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSupplyAirHumidityTooLow OBJECT-TYPE Supply air humidity too low (8516). | 1.3.6.1.4.1.318.1.1.13.5.3.43.17 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmWaterTemperatureTooLow OBJECT-TYPE Water temperature too low (8517). | 1.3.6.1.4.1.318.1.1.13.5.3.43.18 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor1Failure OBJECT-TYPE Sensor #1 failure (8518). | 1.3.6.1.4.1.318.1.1.13.5.3.43.19 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor2Failure OBJECT-TYPE Sensor #2 failure (8519). | 1.3.6.1.4.1.318.1.1.13.5.3.43.20 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor3Failure OBJECT-TYPE Sensor #3 failure (8520). | 1.3.6.1.4.1.318.1.1.13.5.3.43.21 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor4Failure OBJECT-TYPE Sensor #4 failure (8521). | 1.3.6.1.4.1.318.1.1.13.5.3.43.22 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor5Failure OBJECT-TYPE Sensor #5 failure (8522). | 1.3.6.1.4.1.318.1.1.13.5.3.43.23 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor6Failure OBJECT-TYPE Sensor #6 failure (8523). | 1.3.6.1.4.1.318.1.1.13.5.3.43.24 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor7Failure OBJECT-TYPE Sensor #7 failure (8524). | 1.3.6.1.4.1.318.1.1.13.5.3.43.25 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor8Failure OBJECT-TYPE Sensor #8 failure (8525). | 1.3.6.1.4.1.318.1.1.13.5.3.43.26 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor9Failure OBJECT-TYPE Sensor #9 failure (8526). | 1.3.6.1.4.1.318.1.1.13.5.3.43.27 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor10Failure OBJECT-TYPE Sensor #10 failure (8527). | 1.3.6.1.4.1.318.1.1.13.5.3.43.28 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor11Failure OBJECT-TYPE Sensor #11 failure (8528). | 1.3.6.1.4.1.318.1.1.13.5.3.43.29 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor12Failure OBJECT-TYPE Sensor #12 failure (8529). | 1.3.6.1.4.1.318.1.1.13.5.3.43.30 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor13Failure OBJECT-TYPE Sensor #13 failure (8530). | 1.3.6.1.4.1.318.1.1.13.5.3.43.31 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor14Failure OBJECT-TYPE Sensor #14 failure (8531). | 1.3.6.1.4.1.318.1.1.13.5.3.43.32 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor15Failure OBJECT-TYPE Sensor #15 failure (8532). | 1.3.6.1.4.1.318.1.1.13.5.3.43.33 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor16Failure OBJECT-TYPE Sensor #16 failure (8533). | 1.3.6.1.4.1.318.1.1.13.5.3.43.34 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor17Failure OBJECT-TYPE Sensor #17 failure (8534). | 1.3.6.1.4.1.318.1.1.13.5.3.43.35 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor18Failure OBJECT-TYPE Sensor #18 failure (8535). | 1.3.6.1.4.1.318.1.1.13.5.3.43.36 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor19Failure OBJECT-TYPE Sensor #19 failure (8536). | 1.3.6.1.4.1.318.1.1.13.5.3.43.37 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor20Failure OBJECT-TYPE Sensor #20 failure (8537). | 1.3.6.1.4.1.318.1.1.13.5.3.43.38 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor21Failure OBJECT-TYPE Sensor #21 failure (8538). | 1.3.6.1.4.1.318.1.1.13.5.3.43.39 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor1Defect OBJECT-TYPE Sensor #1 defect (8539). | 1.3.6.1.4.1.318.1.1.13.5.3.43.40 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor2Defect OBJECT-TYPE Sensor #2 defect (8540). | 1.3.6.1.4.1.318.1.1.13.5.3.43.41 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor3Defect OBJECT-TYPE Sensor #3 defect (8541). | 1.3.6.1.4.1.318.1.1.13.5.3.43.42 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor4Defect OBJECT-TYPE Sensor #4 defect (8542). | 1.3.6.1.4.1.318.1.1.13.5.3.43.43 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor5Defect OBJECT-TYPE Sensor #5 defect (8543). | 1.3.6.1.4.1.318.1.1.13.5.3.43.44 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor6Defect OBJECT-TYPE Sensor #6 defect (8544). | 1.3.6.1.4.1.318.1.1.13.5.3.43.45 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor7Defect OBJECT-TYPE Sensor #7 defect (8545). | 1.3.6.1.4.1.318.1.1.13.5.3.43.46 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor8Defect OBJECT-TYPE Sensor #8 defect (8546). | 1.3.6.1.4.1.318.1.1.13.5.3.43.47 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor9Defect OBJECT-TYPE Sensor #9 defect (8547). | 1.3.6.1.4.1.318.1.1.13.5.3.43.48 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor10Defect OBJECT-TYPE Sensor #10 defect (8548). | 1.3.6.1.4.1.318.1.1.13.5.3.43.49 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor11Defect OBJECT-TYPE Sensor #11 defect (8549). | 1.3.6.1.4.1.318.1.1.13.5.3.43.50 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor12Defect OBJECT-TYPE Sensor #12 defect (8550). | 1.3.6.1.4.1.318.1.1.13.5.3.43.51 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor13Defect OBJECT-TYPE Sensor #13 defect (8551). | 1.3.6.1.4.1.318.1.1.13.5.3.43.52 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor14Defect OBJECT-TYPE Sensor #14 defect (8552). | 1.3.6.1.4.1.318.1.1.13.5.3.43.53 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor15Defect OBJECT-TYPE Sensor #15 defect (8553). | 1.3.6.1.4.1.318.1.1.13.5.3.43.54 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor16Defect OBJECT-TYPE Sensor #16 defect (8554). | 1.3.6.1.4.1.318.1.1.13.5.3.43.55 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor17Defect OBJECT-TYPE Sensor #17 defect (8555). | 1.3.6.1.4.1.318.1.1.13.5.3.43.56 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor18Defect OBJECT-TYPE Sensor #18 defect (8556) | 1.3.6.1.4.1.318.1.1.13.5.3.43.57 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor19Defect OBJECT-TYPE Sensor #19 defect (8557). | 1.3.6.1.4.1.318.1.1.13.5.3.43.58 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor20Defect OBJECT-TYPE Sensor #20 defect (8558). | 1.3.6.1.4.1.318.1.1.13.5.3.43.59 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmSensor21Defect OBJECT-TYPE Sensor #21 defect (8559). | 1.3.6.1.4.1.318.1.1.13.5.3.43.60 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCompressor1Alarm OBJECT-TYPE Compressor #1 alarm (8560). | 1.3.6.1.4.1.318.1.1.13.5.3.43.61 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCompressor2Alarm OBJECT-TYPE Compressor #2 alarm (8561). | 1.3.6.1.4.1.318.1.1.13.5.3.43.62 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCompressor1LowPressure OBJECT-TYPE Compressor #1 low pressure (8562). | 1.3.6.1.4.1.318.1.1.13.5.3.43.63 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmCompressor2LowPressure OBJECT-TYPE Compressor #2 low pressure (8563). | 1.3.6.1.4.1.318.1.1.13.5.3.43.64 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReheat1Failure OBJECT-TYPE Reheat #1 failure (8564). | 1.3.6.1.4.1.318.1.1.13.5.3.43.65 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReheat2Failure OBJECT-TYPE Reheat #2 failure (8565). | 1.3.6.1.4.1.318.1.1.13.5.3.43.66 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReheat3Failure OBJECT-TYPE Reheat #3 failure (8566). | 1.3.6.1.4.1.318.1.1.13.5.3.43.67 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmReheat4Failure OBJECT-TYPE Reheat #4 failure (8567). | 1.3.6.1.4.1.318.1.1.13.5.3.43.68 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmDrycooler1Failure OBJECT-TYPE Drycooler #1 failure (8568). | 1.3.6.1.4.1.318.1.1.13.5.3.43.69 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmDrycooler2Failure OBJECT-TYPE Drycooler #2 failure (8569). | 1.3.6.1.4.1.318.1.1.13.5.3.43.70 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmDrycooler3Failure OBJECT-TYPE Drycooler #3 failure (8570). | 1.3.6.1.4.1.318.1.1.13.5.3.43.71 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmDrycooler4Failure OBJECT-TYPE Drycooler #4 failure (8571). | 1.3.6.1.4.1.318.1.1.13.5.3.43.72 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmPump1Failure OBJECT-TYPE Pump #1 failure (8572). | 1.3.6.1.4.1.318.1.1.13.5.3.43.73 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmPump2Failure OBJECT-TYPE Pump #2 failure (8573). | 1.3.6.1.4.1.318.1.1.13.5.3.43.74 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmPump3Failure OBJECT-TYPE Pump #3 failure (8574). | 1.3.6.1.4.1.318.1.1.13.5.3.43.75 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmPump4Failure OBJECT-TYPE Pump #4 failure (8575). | 1.3.6.1.4.1.318.1.1.13.5.3.43.76 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier1Failure OBJECT-TYPE Humidifier #1 failure (8576). | 1.3.6.1.4.1.318.1.1.13.5.3.43.77 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier2Failure OBJECT-TYPE Humidifier #2 failure (8577). | 1.3.6.1.4.1.318.1.1.13.5.3.43.78 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier3Failure OBJECT-TYPE Humidifier #3 failure (8578). | 1.3.6.1.4.1.318.1.1.13.5.3.43.79 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier1Alarm5us OBJECT-TYPE Humidifier #1 5us alarm (8579). | 1.3.6.1.4.1.318.1.1.13.5.3.43.80 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier2Alarm5us OBJECT-TYPE Humidifier #2 5us alarm (8580). | 1.3.6.1.4.1.318.1.1.13.5.3.43.81 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier3Alarm5us OBJECT-TYPE Humidifier #3 5us alarm (8581). | 1.3.6.1.4.1.318.1.1.13.5.3.43.82 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier1Alarm20us OBJECT-TYPE Humidifier #1 20us alarm (8582). | 1.3.6.1.4.1.318.1.1.13.5.3.43.83 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier2Alarm20us OBJECT-TYPE Humidifier #2 20us alarm (8583). | 1.3.6.1.4.1.318.1.1.13.5.3.43.84 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHumidifier3Alarm20us OBJECT-TYPE Humidifier #3 20us alarm (8584). | 1.3.6.1.4.1.318.1.1.13.5.3.43.85 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFan1Alarm OBJECT-TYPE Fan #1 alarm (8585). | 1.3.6.1.4.1.318.1.1.13.5.3.43.86 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFan2Alarm OBJECT-TYPE Fan #2 alarm (8586). | 1.3.6.1.4.1.318.1.1.13.5.3.43.87 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFan3Alarm OBJECT-TYPE Fan #3 alarm (8587). | 1.3.6.1.4.1.318.1.1.13.5.3.43.88 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFilter1Clogged OBJECT-TYPE Filter #1 clogged (8588). | 1.3.6.1.4.1.318.1.1.13.5.3.43.89 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFilter2Clogged OBJECT-TYPE Filter #2 clogged (8589). | 1.3.6.1.4.1.318.1.1.13.5.3.43.90 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmFilter3Clogged OBJECT-TYPE Filter #3 clogged (8590). | 1.3.6.1.4.1.318.1.1.13.5.3.43.91 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm1 OBJECT-TYPE Auxiliary #1 alarm (8591). | 1.3.6.1.4.1.318.1.1.13.5.3.43.92 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm2 OBJECT-TYPE Auxiliary #2 alarm (8592). | 1.3.6.1.4.1.318.1.1.13.5.3.43.93 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm3 OBJECT-TYPE Auxiliary #3 alarm (8593). | 1.3.6.1.4.1.318.1.1.13.5.3.43.94 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm4 OBJECT-TYPE Auxiliary #4 alarm (8594). | 1.3.6.1.4.1.318.1.1.13.5.3.43.95 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm5 OBJECT-TYPE Auxiliary #5 alarm (8595). | 1.3.6.1.4.1.318.1.1.13.5.3.43.96 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm6 OBJECT-TYPE Auxiliary #6 alarm (8596). | 1.3.6.1.4.1.318.1.1.13.5.3.43.97 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm7 OBJECT-TYPE Auxiliary #7 alarm (8597). | 1.3.6.1.4.1.318.1.1.13.5.3.43.98 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm8 OBJECT-TYPE Auxiliary #8 alarm (8598). | 1.3.6.1.4.1.318.1.1.13.5.3.43.99 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm9 OBJECT-TYPE Auxiliary #9 alarm (8599). | 1.3.6.1.4.1.318.1.1.13.5.3.43.100 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmAuxiliaryAlarm10 OBJECT-TYPE Auxiliary #10 alarm (8600). | 1.3.6.1.4.1.318.1.1.13.5.3.43.101 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmHotGasHeatingAlarm OBJECT-TYPE Hot gas heating alarm (8601). | 1.3.6.1.4.1.318.1.1.13.5.3.43.102 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmEEV1PressureSensorError OBJECT-TYPE EEV1 pressure sensor error (8602). | 1.3.6.1.4.1.318.1.1.13.5.3.43.103 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmEEV1TemperatureSensorError OBJECT-TYPE EEV1 temperature sensor error (8603). | 1.3.6.1.4.1.318.1.1.13.5.3.43.104 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmEEV1StepperMotorError OBJECT-TYPE EEV1 stepper motor error (8604). | 1.3.6.1.4.1.318.1.1.13.5.3.43.105 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmEEV2PressureSensorError OBJECT-TYPE EEV2 pressure sensor error (8605). | 1.3.6.1.4.1.318.1.1.13.5.3.43.106 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmEEV2TemperatureSensorError OBJECT-TYPE EEV2 temperature sensor error (8606). | 1.3.6.1.4.1.318.1.1.13.5.3.43.107 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmEEV2StepperMotorError OBJECT-TYPE EEV2 stepper motor error (8607). | 1.3.6.1.4.1.318.1.1.13.5.3.43.108 | AirIRmAlarmState | read-only | mandatory |
| airIRmPmMyZone OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.44 | |||
| airIRmPmMyZoneNumber OBJECT-TYPE My zone number (11700). | 1.3.6.1.4.1.318.1.1.13.5.3.44.1 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneRoomTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.44.2 | |||
| airIRmPmMyZoneRoomTemperatureC OBJECT-TYPE My zone room temperature in tenths of degrees Celsius (11701). | 1.3.6.1.4.1.318.1.1.13.5.3.44.2.1 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneRoomTemperatureF OBJECT-TYPE My zone room temperature in tenths of degrees Fahrenheit (11701). | 1.3.6.1.4.1.318.1.1.13.5.3.44.2.2 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneRoomHumidity OBJECT-TYPE My zone room humidity in tenths of %RH (11702). | 1.3.6.1.4.1.318.1.1.13.5.3.44.3 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneSupplyTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.44.4 | |||
| airIRmPmMyZoneSupplyTemperatureC OBJECT-TYPE My zone supply temperature in tenths of degrees Celsius (11703). | 1.3.6.1.4.1.318.1.1.13.5.3.44.4.1 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneSupplyTemperatureF OBJECT-TYPE My zone supply temperature in tenths of degrees Fahrenheit (11703). | 1.3.6.1.4.1.318.1.1.13.5.3.44.4.2 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneSupplyHumidity OBJECT-TYPE My zone supply humidity in tenths of %RH (11704). | 1.3.6.1.4.1.318.1.1.13.5.3.44.5 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneSequencingTime OBJECT-TYPE My zone sequencing time in minutes (11705). | 1.3.6.1.4.1.318.1.1.13.5.3.44.6 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneNumberOfErrorUnits OBJECT-TYPE Number of error units in my zone (11706). | 1.3.6.1.4.1.318.1.1.13.5.3.44.7 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneEmergencyTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.44.8 | |||
| airIRmPmMyZoneEmergencyTemperatureC OBJECT-TYPE My zone emergency temperature in tenths of degrees Celsius (11707). | 1.3.6.1.4.1.318.1.1.13.5.3.44.8.1 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneEmergencyTemperatureF OBJECT-TYPE My zone emergency temperature in tenths of degrees Fahrenheit (11707). | 1.3.6.1.4.1.318.1.1.13.5.3.44.8.2 | INTEGER | read-only | mandatory |
| airIRmPmMyZoneCWEnergySaveMode OBJECT-TYPE My zone CW energy save mode (11708). | 1.3.6.1.4.1.318.1.1.13.5.3.44.9 | AirIRmActivityState | read-only | mandatory |
| airIRmPmGlobalZoneData OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.5.3.45 | |||
| airIRmPmGlobalZoneDataEmergencyOpMode OBJECT-TYPE Emergency operation mode (11800). | 1.3.6.1.4.1.318.1.1.13.5.3.45.1 | AirIRmActivityState | read-only | mandatory |
| airIRGen3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.6 | |||
| airIRG3Ident OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.6.1 | |||
| airIRG3IdentTableSize OBJECT-TYPE The ident table size. | 1.3.6.1.4.1.318.1.1.13.6.1.1 | INTEGER | read-only | mandatory |
| airIRG3IdentTable OBJECT-TYPE Allows to get ident information of current RDU and its assigned CM's. | 1.3.6.1.4.1.318.1.1.13.6.1.2 | not-accessible | mandatory | |
| airIRG3IdentEntry OBJECT-TYPE The ident table entry. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1 | not-accessible | mandatory | |
| airIRG3IdentIndex OBJECT-TYPE Index of ident table. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.1 | INTEGER | read-only | mandatory |
| airIRG3IdentName OBJECT-TYPE A character string identifying the unit name. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.2 | DisplayString | read-write | mandatory |
| airIRG3IdentLocation OBJECT-TYPE A character string identifying the unit location. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.3 | DisplayString | read-write | mandatory |
| airIRG3IdentModelNumber OBJECT-TYPE A character string identifying the unit model number. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.4 | DisplayString | read-only | mandatory |
| airIRG3IdentSerialNumber OBJECT-TYPE A character string identifying the unit serial number. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.5 | DisplayString | read-only | mandatory |
| airIRG3IdentFirmwareRevision OBJECT-TYPE A character string identifying the unit firmware version. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.6 | DisplayString | read-only | mandatory |
| airIRG3IdentHardwareRevision OBJECT-TYPE A character string identifying the unit controller hardware revision. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.7 | DisplayString | read-only | mandatory |
| airIRG3IdentManufactureDate OBJECT-TYPE A character string identifying the unit manufacture date. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.8 | DisplayString | read-only | mandatory |
| airIRG3IdentRDUSysOID OBJECT-TYPE This OID contains an OID path to the RDU data. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.9 | OBJECT IDENTIFIER | read-only | mandatory |
| airIRG3IdentCMSysOID OBJECT-TYPE This OID contains an OID path to the cooling module data. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.10 | OBJECT IDENTIFIER | read-only | mandatory |
| airIRG3IdentGroupSysOID OBJECT-TYPE This OID contains an OID path to the group data. | 1.3.6.1.4.1.318.1.1.13.6.1.2.1.11 | OBJECT IDENTIFIER | read-only | mandatory |
| airIRG3Group OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.6.2 | |||
| airIRG3GroupTableSize OBJECT-TYPE The group table size. | 1.3.6.1.4.1.318.1.1.13.6.2.1 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusTable OBJECT-TYPE Allows to get group status information. | 1.3.6.1.4.1.318.1.1.13.6.2.2 | not-accessible | mandatory | |
| airIRG3GroupStatusEntry OBJECT-TYPE The group staus table entry. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1 | not-accessible | mandatory | |
| airIRG3GroupStatusIndex OBJECT-TYPE Index of group status table. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.1 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusCoolOutput OBJECT-TYPE The group cooling output in tenths of kilowatts (kW). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.2 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusCoolDemand OBJECT-TYPE The group cooling demand in tenths of kilowatts (kW). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.3 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAirFlowUS OBJECT-TYPE The group air flow in cubic feet per minute (CFM). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.4 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAirFlowMetric OBJECT-TYPE The group air flow in liters per second (L/s). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.5 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMaxRackInletTempUS OBJECT-TYPE The group maximum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.6 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMaxRackInletTempMetric OBJECT-TYPE The group maximum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.7 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMinRackInletTempUS OBJECT-TYPE The group minimum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.8 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMinRackInletTempMetric OBJECT-TYPE The group minimum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.9 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMaxReturnAirTempUS OBJECT-TYPE The group maximum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.10 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMaxReturnAirTempMetric OBJECT-TYPE The group maximum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.11 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMinReturnAirTempUS OBJECT-TYPE The group minimum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.12 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusMinReturnAirTempMetric OBJECT-TYPE The group minimum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.13 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgSupplyTempUS OBJECT-TYPE The group average supply air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.14 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgSupplyTempMetric OBJECT-TYPE The group average supply air temperature in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.15 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgReturnTempUS OBJECT-TYPE The group average return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.16 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgReturnTempMetric OBJECT-TYPE The group average return air temperature in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.17 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgFanSpeed OBJECT-TYPE The group average fan speed in revolutions per minute (RPM). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.18 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgAirFlowUS OBJECT-TYPE The group average air flow in cubic feet per minute (CFM). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.19 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusAvgAirFlowMetric OBJECT-TYPE The group average air flow in liters per second (L/s). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.20 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusTotalAirFlowUS OBJECT-TYPE The group total air flow in cubic feet per minute (CFM). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.21 | INTEGER | read-only | mandatory |
| airIRG3GroupStatusTotalAirFlowMetric OBJECT-TYPE The group total air flow in liters per second (L/s). Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.2.1.22 | INTEGER | read-only | mandatory |
| airIRG3GroupSetpointsTable OBJECT-TYPE Allows to access the group setpoints. | 1.3.6.1.4.1.318.1.1.13.6.2.3 | not-accessible | mandatory | |
| airIRG3GroupSetpointsEntry OBJECT-TYPE The group setpoints table entry. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1 | not-accessible | mandatory | |
| airIRG3GroupSetpointsIndex OBJECT-TYPE Index of group setpoints table. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.1 | INTEGER | read-only | mandatory |
| airIRG3GroupSetpointsCoolSetpointUS OBJECT-TYPE Group cooling setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.2 | INTEGER | read-write | mandatory |
| airIRG3GroupSetpointsCoolSetpointMetric OBJECT-TYPE Group cooling setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.3 | INTEGER | read-write | mandatory |
| airIRG3GroupSetpointsCoolDeadbandUS OBJECT-TYPE Group cooling deadband in tenths of degrees Fahrenheit. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.4 | INTEGER | read-write | mandatory |
| airIRG3GroupSetpointsCoolDeadbandMetric OBJECT-TYPE Group cooling deadband in tenths of degrees Celsius. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.5 | INTEGER | read-write | mandatory |
| airIRG3GroupSetpointsFanSpeedPreference OBJECT-TYPE The group preferred fan speed setting. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.6 | INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)} | read-write | mandatory |
| airIRG3GroupSetpointsSupplyAirSetpointUS OBJECT-TYPE Group supply air setpoint in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.7 | INTEGER | read-write | mandatory |
| airIRG3GroupSetpointsSupplyAirSetpointMetric OBJECT-TYPE Group supply air setpoint in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.8 | INTEGER | read-write | mandatory |
| airIRG3GroupSetpointsAirFlowControl OBJECT-TYPE The group air flow control. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.9 | INTEGER {automatic(1), manual(2)} | read-write | mandatory |
| airIRG3GroupSetpointsLightingOnTime OBJECT-TYPE The group lighting on time in minutes. | 1.3.6.1.4.1.318.1.1.13.6.2.3.1.10 | INTEGER | read-write | mandatory |
| airIRG3GroupConfigTable OBJECT-TYPE Allows to access group configuration table. | 1.3.6.1.4.1.318.1.1.13.6.2.4 | not-accessible | mandatory | |
| airIRG3GroupConfigEntry OBJECT-TYPE The group config table entry. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1 | not-accessible | mandatory | |
| airIRG3GroupConfigIndex OBJECT-TYPE Index of group config table. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.1 | INTEGER | read-only | mandatory |
| airIRG3GroupConfigNumberofCoolingUnits OBJECT-TYPE The number of cooling units. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.2 | INTEGER | read-write | mandatory |
| airIRG3GroupConfigConfigurationType OBJECT-TYPE The group configuration type. The spot configuration type is not supported. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.3 | INTEGER {racs(1), spot(2), in-row(3), hacs(4)} | read-write | mandatory |
| airIRG3GroupConfigCapacityControlType OBJECT-TYPE The group capacity control. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.4 | INTEGER {discrete(1), proportional(2)} | read-write | mandatory |
| airIRG3GroupConfigFanSpeedControl OBJECT-TYPE The group fan speed control. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.5 | INTEGER {automatic(1), manual(2)} | read-write | mandatory |
| airIRG3GroupConfigCoolGainP OBJECT-TYPE The gain component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.6 | INTEGER | read-write | mandatory |
| airIRG3GroupConfigCoolResetRateI OBJECT-TYPE The integral component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.7 | INTEGER | read-write | mandatory |
| airIRG3GroupConfigCoolDerivativeD OBJECT-TYPE The derivative component of the PID in hundredths. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.8 | INTEGER | read-write | mandatory |
| airIRG3GroupConfigCoolPIDReset OBJECT-TYPE Will reset the PID coefficients back to the factory defaults. Readback is not supported, returns -1. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.9 | INTEGER {readBack(1), reset(2)} | read-write | mandatory |
| airIRG3GroupConfigNumberofBackupUnits OBJECT-TYPE The number of backup units. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.10 | INTEGER | read-write | mandatory |
| airIRG3GroupConfigRuntimeBalancingEnable OBJECT-TYPE Enable or disable runtime balancing feature. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.11 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRG3GroupConfigLoadAssistEnable OBJECT-TYPE Enable or disable load assist feature. | 1.3.6.1.4.1.318.1.1.13.6.2.4.1.12 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRG3Alarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.6.3 | |||
| airIRG3AlarmsTableSize OBJECT-TYPE The number of active alarms in the airIRG3AlarmsTable. | 1.3.6.1.4.1.318.1.1.13.6.3.1 | INTEGER | read-only | mandatory |
| airIRG3AlarmsTable OBJECT-TYPE Table of active alarms for the device. | 1.3.6.1.4.1.318.1.1.13.6.3.2 | not-accessible | mandatory | |
| airIRG3AlarmsEntry OBJECT-TYPE Alarms specification | 1.3.6.1.4.1.318.1.1.13.6.3.2.1 | not-accessible | mandatory | |
| airIRG3AlarmsIndex OBJECT-TYPE Alarm index. | 1.3.6.1.4.1.318.1.1.13.6.3.2.1.1 | INTEGER | read-only | mandatory |
| airIRG3AlarmsEventCode OBJECT-TYPE Event Code for the alarm. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.3.2.1.2 | INTEGER | read-only | mandatory |
| airIRG3AlarmsDescription OBJECT-TYPE Description of the alarm. Returns (-1) if not supported. | 1.3.6.1.4.1.318.1.1.13.6.3.2.1.3 | DisplayString (SIZE(0..64)) | read-only | mandatory |
| airIRG3RDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.6.4 | |||
| airIRG3RDUTableSize OBJECT-TYPE The RDU table size. | 1.3.6.1.4.1.318.1.1.13.6.4.1 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusTable OBJECT-TYPE Allows to access RDU status table. | 1.3.6.1.4.1.318.1.1.13.6.4.2 | not-accessible | mandatory | |
| airIRG3RDUStatusEntry OBJECT-TYPE The RDU status table entry. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1 | not-accessible | mandatory | |
| airIRG3RDUStatusDeviceIndex OBJECT-TYPE Index of RDU status table. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.1 | INTEGER | read-only | mandatory |
| airIRG3RDUID OBJECT-TYPE The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.2 | DisplayString | read-only | mandatory |
| airIRG3RDUStatusOnReadyStandby OBJECT-TYPE The RDU current status. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.3 | INTEGER {standby(1), ready(2), on(3)} | read-only | mandatory |
| airIRG3RDUStatusOperatingMode OBJECT-TYPE The RDU actual operating mode. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.4 | INTEGER {standby(1), ready(2), on(3), stop(4), maintenancemode(5)} | read-only | mandatory |
| airIRG3RDUStatusLeadPump OBJECT-TYPE The RDU lead pump. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.5 | INTEGER {pump1(1), pump2(2)} | read-only | mandatory |
| airIRG3RDUStatusStartupDelay OBJECT-TYPE The RDU start up delay in seconds. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.6 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPumpChangeOverInterval OBJECT-TYPE The RDU pump change over interval in days. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.7 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusStopOnLeakDetect OBJECT-TYPE The RDU status of stop on leak detect. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.8 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| airIRG3RDUStatusPowerSource OBJECT-TYPE The RDU power source status. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.9 | INTEGER {singleFeed(1), dualFeed(2)} | read-only | mandatory |
| airIRG3RDUStatusTotalRDUOutputPower OBJECT-TYPE The RDU output power in tenths of kilowatts (kW). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.10 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusInletWaterTempUS OBJECT-TYPE The RDU inlet water temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.11 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusInletWaterTempMetric OBJECT-TYPE The RDU inlet water temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.12 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusOutletWaterTempUS OBJECT-TYPE The RDU outlet water temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.13 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusOutletWaterTempMetric OBJECT-TYPE The RDU outlet water temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.14 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserSaturationTempUS OBJECT-TYPE The RDU condenser saturation temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.15 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserSaturationTempMetric OBJECT-TYPE The RDU condenser saturation temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.16 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusDewPointTempUS OBJECT-TYPE The RDU dew point temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.17 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusDewPointTempMetric OBJECT-TYPE The RDU dew point temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.18 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPumpOutletTempUS OBJECT-TYPE The RDU pump outlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.19 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPumpOutletTempMetric OBJECT-TYPE The RDU pump outlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.20 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusSubcoolerOutletTempUS OBJECT-TYPE The RDU sub cooler outlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.21 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusSubcoolerOutletTempMetric OBJECT-TYPE The RDU sub cooler outlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.22 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserOutletTempUS OBJECT-TYPE The RDU condenser outlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.23 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserOutletTempMetric OBJECT-TYPE The RDU condenser outlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.24 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserInletTempUS OBJECT-TYPE The RDU condenser inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.25 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserInletTempMetric OBJECT-TYPE The RDU condenser inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.26 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserOutletPressureUS OBJECT-TYPE The RDU condenser outlet pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.27 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCondenserOutletPressureMetric OBJECT-TYPE The RDU condenser outlet pressure in kiloPascals (KPa). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.28 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPump1HeadPressureUS OBJECT-TYPE The RDU Pump 1 head pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.29 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPump1HeadPressureMetric OBJECT-TYPE The RDU Pump 1 head pressure in kiloPascals (KPa). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.30 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPump2HeadPressureUS OBJECT-TYPE The RDU Pump 2 head pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.31 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPump2HeadPressureMetric OBJECT-TYPE The RDU Pump 2 head pressure in kiloPascals (KPa). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.32 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPump1Speed OBJECT-TYPE The RDU Pump 1 speed in revolutions per minute (RPM). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.33 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusPump2Speed OBJECT-TYPE The RDU Pump 2 speed in revolutions per minute (RPM). | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.34 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusCWValvePosition OBJECT-TYPE The RDU CW Valve position in % open | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.35 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusReceiverLiquidLevel OBJECT-TYPE The RDU receiver liquid level in % Full | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.36 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusDCPowerSupply1Current OBJECT-TYPE The RDU DC Power Supply 1 Current in Amps | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.37 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusDCPowerSupply2Current OBJECT-TYPE The RDU DC Power Supply 2 Current in Amps | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.38 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusTotalDCPowerSupplyCurrent OBJECT-TYPE The RDU Total DC Power Supply Current in Amps | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.39 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusInputState OBJECT-TYPE The RDU Input state. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.40 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRG3RDUStatusOutputState OBJECT-TYPE The RDU Output state | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.41 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| airIRG3RDUStatusByPassValvePosition OBJECT-TYPE The RDU By Pass Valve position in % open | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.42 | INTEGER | read-only | mandatory |
| airIRG3RDUStatusRefrigerantLeakDetector OBJECT-TYPE The RDU refrigerant leak detector status. | 1.3.6.1.4.1.318.1.1.13.6.4.2.1.43 | INTEGER {suspended(1), calibrating(2), operating(3), disabled(4)} | read-only | mandatory |
| airIRG3RDURunHoursTable OBJECT-TYPE Allows to access RDU run hours table. | 1.3.6.1.4.1.318.1.1.13.6.4.3 | not-accessible | mandatory | |
| airIRG3RDURunHoursEntry OBJECT-TYPE The RDU run hours table entry. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1 | not-accessible | mandatory | |
| airIRG3RDURunHoursDeviceIndex OBJECT-TYPE Index of RDU run hours table. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1.1 | INTEGER | read-only | mandatory |
| airIRG3RDURunHoursRDUID OBJECT-TYPE The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1.2 | DisplayString | read-only | mandatory |
| airIRG3RDURunHoursPump1 OBJECT-TYPE The RDU run hours of Pump 1. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1.3 | INTEGER | read-only | mandatory |
| airIRG3RDURunHoursPump2 OBJECT-TYPE The RDU run hours of Pump 2. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1.4 | INTEGER | read-only | mandatory |
| airIRG3RDURunHoursPowerSupply1 OBJECT-TYPE The RDU run hours of power supply 1. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1.5 | INTEGER | read-only | mandatory |
| airIRG3RDURunHoursPowerSupply2 OBJECT-TYPE The RDU run hours of power supply 2. | 1.3.6.1.4.1.318.1.1.13.6.4.3.1.6 | INTEGER | read-only | mandatory |
| airIRG3RDUServiceIntervalsTable OBJECT-TYPE Allows to access RDU service intervals table. | 1.3.6.1.4.1.318.1.1.13.6.4.4 | not-accessible | mandatory | |
| airIRG3RDUServiceIntervalsEntry OBJECT-TYPE The service interval table entry. | 1.3.6.1.4.1.318.1.1.13.6.4.4.1 | not-accessible | mandatory | |
| airIRG3RDUServiceIntervalsDeviceIndex OBJECT-TYPE Index of service interval table. | 1.3.6.1.4.1.318.1.1.13.6.4.4.1.1 | INTEGER | read-only | mandatory |
| airIRG3RDUServiceIntervalsRDUID OBJECT-TYPE The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. | 1.3.6.1.4.1.318.1.1.13.6.4.4.1.2 | DisplayString | read-only | mandatory |
| airIRG3RDUServiceIntervalsAirFilterInterval OBJECT-TYPE The RDU service interval for air filter in hours. Returns -1 if not supported. | 1.3.6.1.4.1.318.1.1.13.6.4.4.1.3 | INTEGER | read-write | mandatory |
| airIRG3RDUServiceIntervalsAirFilterAlarm OBJECT-TYPE The RDU service interval air filter alarm status. Returns -1 if not supported. | 1.3.6.1.4.1.318.1.1.13.6.4.4.1.4 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| airIRG3RDUThresholdsTable OBJECT-TYPE Allows to access RDU thresholds table. | 1.3.6.1.4.1.318.1.1.13.6.4.5 | not-accessible | mandatory | |
| airIRG3RDUThresholdsEntry OBJECT-TYPE The RDU thresholds table entry. | 1.3.6.1.4.1.318.1.1.13.6.4.5.1 | not-accessible | mandatory | |
| airIRG3RDUThresholdsDeviceIndex OBJECT-TYPE Index of RDU thresholds table. | 1.3.6.1.4.1.318.1.1.13.6.4.5.1.1 | INTEGER | read-only | mandatory |
| airIRG3RDUThresholdsRDUID OBJECT-TYPE The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. | 1.3.6.1.4.1.318.1.1.13.6.4.5.1.2 | DisplayString | read-only | mandatory |
| airIRG3RDUThresholdsEnteringFluidTempHighUS OBJECT-TYPE The RDU threshold for entering fluid temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.4.5.1.3 | INTEGER | read-write | mandatory |
| airIRG3RDUThresholdsEnteringFluidTempHighMetric OBJECT-TYPE The RDU threshold for entering fluid temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.4.5.1.4 | INTEGER | read-write | mandatory |
| airIRG3RDUSetpointsTable OBJECT-TYPE Allows to access RDU set points table. | 1.3.6.1.4.1.318.1.1.13.6.4.6 | not-accessible | mandatory | |
| airIRG3RDUSetpointsEntry OBJECT-TYPE The RDU set points table entry. | 1.3.6.1.4.1.318.1.1.13.6.4.6.1 | not-accessible | mandatory | |
| airIRG3RDUSetpointsDeviceIndex OBJECT-TYPE Index of RDU set points table. | 1.3.6.1.4.1.318.1.1.13.6.4.6.1.1 | INTEGER | read-only | mandatory |
| airIRG3RDUConfigTable OBJECT-TYPE Allows to access RDU configuration table. | 1.3.6.1.4.1.318.1.1.13.6.4.7 | not-accessible | mandatory | |
| airIRG3RDUConfigEntry OBJECT-TYPE The RDU configuration table entry. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1 | not-accessible | mandatory | |
| airIRG3RDUConfigDeviceIndex OBJECT-TYPE Index of RDU configuration table. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.1 | INTEGER | read-only | mandatory |
| airIRG3RDUConfigRDUID OBJECT-TYPE The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.2 | DisplayString | read-only | mandatory |
| airIRG3RDUConfigStopOnLeakDetect OBJECT-TYPE The RDU stop on leak detect set. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| airIRG3RDUConfigStartupDelay OBJECT-TYPE The RDU start up delay in seconds. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.4 | INTEGER | read-write | mandatory |
| airIRG3RDUConfigPumpChangeOverInterval OBJECT-TYPE The RDU pump change over interval in days. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.5 | INTEGER | read-write | mandatory |
| airIRG3RDUConfigPowerSource OBJECT-TYPE The RDU power source. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.6 | INTEGER {singleFeed(1), dualFeed(2)} | read-write | mandatory |
| airIRG3RDUConfigOutputSource OBJECT-TYPE The RDU output source. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.7 | INTEGER {anyalarm(1), onlycriticalalarms(2)} | read-write | mandatory |
| airIRG3RDUConfigInputNormalState OBJECT-TYPE The RDU Input Normal State. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.8 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRG3RDUConfigOutputNormalState OBJECT-TYPE The RDU Output Normal State. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.9 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| airIRG3RDUConfigByPassValveEnabled OBJECT-TYPE The RDU By Pass Valve Enabled State. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.10 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| airIRG3RDUConfigRefrigerantLeakDetectorEnabled OBJECT-TYPE The RDU Refrigerant Leak Detector Enabled State. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.11 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| airIRG3RDUConfigCalibrateRefrigerantLeakDetector OBJECT-TYPE This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only. The read returns -1. Only 'yes' is supported. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.12 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| airIRG3RDUConfigOnReadyStandby OBJECT-TYPE This parameter allows to configure RDU on/standby parameter. Ready is currently not supported. If unsupported returns -1. | 1.3.6.1.4.1.318.1.1.13.6.4.7.1.13 | INTEGER {standby(1), ready(2), on(3)} | read-write | mandatory |
| airIRG3CM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.13.6.5 | |||
| airIRG3CMTableSize OBJECT-TYPE The cooling module table size. | 1.3.6.1.4.1.318.1.1.13.6.5.1 | INTEGER | read-only | mandatory |
| airIRG3CMStatusTable OBJECT-TYPE Allows to access CM status table. | 1.3.6.1.4.1.318.1.1.13.6.5.2 | not-accessible | mandatory | |
| airIRG3CMStatusEntry OBJECT-TYPE The CM status table entry. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1 | not-accessible | mandatory | |
| airIRG3CMStatusDeviceIndex OBJECT-TYPE Index of CM status table. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.1 | INTEGER | read-only | mandatory |
| airIRG3CMStatusCMID OBJECT-TYPE The CM ID (RDU Number - Group Number - CM Unit Number). | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.2 | DisplayString | read-only | mandatory |
| airIRG3CMStatusOperatingMode OBJECT-TYPE The current operating mode of the CM. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.3 | INTEGER {standBy(1), on(2), idle(3)} | read-only | mandatory |
| airIRG3CMStatusUnitType OBJECT-TYPE The current CM unit type. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.4 | INTEGER {unconfigured(1), oa(2), ra(3)} | read-only | mandatory |
| airIRG3CMStatusRackInletTempUS OBJECT-TYPE The CM rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.5 | INTEGER | read-only | mandatory |
| airIRG3CMStatusRackInletTempMetric OBJECT-TYPE The CM rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.6 | INTEGER | read-only | mandatory |
| airIRG3CMStatusReturnAirTempUS OBJECT-TYPE The CM return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.7 | INTEGER | read-only | mandatory |
| airIRG3CMStatusReturnAirTempMetric OBJECT-TYPE The CM return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.8 | INTEGER | read-only | mandatory |
| airIRG3CMStatusLiquidTempUS OBJECT-TYPE The CM liquid temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.9 | INTEGER | read-only | mandatory |
| airIRG3CMStatusLiquidTempMetric OBJECT-TYPE The CM liquid temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.10 | INTEGER | read-only | mandatory |
| airIRG3CMStatusVaporTempUS OBJECT-TYPE The CM vapor temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.11 | INTEGER | read-only | mandatory |
| airIRG3CMStatusVaporTempMetric OBJECT-TYPE The CM vapor temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.12 | INTEGER | read-only | mandatory |
| airIRG3CMStatusEvaporatorTempUS OBJECT-TYPE The CM saturation temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.13 | INTEGER | read-only | mandatory |
| airIRG3CMStatusEvaporatorTempMetric OBJECT-TYPE The CM saturation temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.14 | INTEGER | read-only | mandatory |
| airIRG3CMStatusLiquidInletPressureUS OBJECT-TYPE The CM Liquid Inlet pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.15 | INTEGER | read-only | mandatory |
| airIRG3CMStatusLiquidInletPressureMetric OBJECT-TYPE The CM Liquid Inlet pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.16 | INTEGER | read-only | mandatory |
| airIRG3CMStatusVaporOutletPressureUS OBJECT-TYPE The CM Vapor Outlet pressure in pounds per square inch (PSI). | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.17 | INTEGER | read-only | mandatory |
| airIRG3CMStatusVaporOutletPressureMetric OBJECT-TYPE The CM Vapor Outlet pressure in kiloPascals (kPa). | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.18 | INTEGER | read-only | mandatory |
| airIRG3CMStatusExpansionValvePosition OBJECT-TYPE The CM expansion valve position in % open | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.19 | INTEGER | read-only | mandatory |
| airIRG3CMStatusEPRValvePosition OBJECT-TYPE The CM Evaporator Pressure Regulator Valve Position in tenths of percent open | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.20 | INTEGER | read-only | mandatory |
| airIRG3CMStatusLocalDisplayOnOffEnabled OBJECT-TYPE The status of the on/off control on the CM local display. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.21 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| airIRG3CMStatusAverageFanSpeed OBJECT-TYPE The CM Average Fan Speed. | 1.3.6.1.4.1.318.1.1.13.6.5.2.1.22 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursTable OBJECT-TYPE Allows to access CM run hours table. | 1.3.6.1.4.1.318.1.1.13.6.5.3 | not-accessible | mandatory | |
| airIRG3CMRunHoursEntry OBJECT-TYPE The CM run hours table entry. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1 | not-accessible | mandatory | |
| airIRG3CMRunHoursDeviceIndex OBJECT-TYPE Index of CM run hours table. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.1 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursCMID OBJECT-TYPE The CM ID (RDU Number - Group Number - CM Unit Number). | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.2 | DisplayString | read-only | mandatory |
| airIRG3CMRunHoursFan1 OBJECT-TYPE The CM run hours for Fan1. Returns (-1) if not appilcable. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.3 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursFan2 OBJECT-TYPE The CM run hours for Fan2. Returns (-1) if not appilcable. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.4 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursFan3 OBJECT-TYPE The CM run hours for Fan3. Returns (-1) if not appilcable. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.5 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursFan4 OBJECT-TYPE The CM run hours for Fan4. Returns (-1) if not appilcable. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.6 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursFan5 OBJECT-TYPE The CM run hours for Fan5. Returns (-1) if not appilcable. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.7 | INTEGER | read-only | mandatory |
| airIRG3CMRunHoursAirFilter OBJECT-TYPE The CM run hours for air filter. | 1.3.6.1.4.1.318.1.1.13.6.5.3.1.8 | INTEGER | read-only | mandatory |
| airIRG3CMServiceIntervalsTable OBJECT-TYPE Allows to access CM service intervals table. | 1.3.6.1.4.1.318.1.1.13.6.5.4 | not-accessible | mandatory | |
| airIRG3CMServiceIntervalsEntry OBJECT-TYPE The CM service interval table entry. | 1.3.6.1.4.1.318.1.1.13.6.5.4.1 | not-accessible | mandatory | |
| airIRG3CMServiceIntervalsDeviceIndex OBJECT-TYPE Index of CM service intervals table. | 1.3.6.1.4.1.318.1.1.13.6.5.4.1.1 | INTEGER | read-only | mandatory |
| airIRG3CMServiceIntervalsCMID OBJECT-TYPE The CM ID (RDU Number - Group Number - CM Unit Number). | 1.3.6.1.4.1.318.1.1.13.6.5.4.1.2 | DisplayString | read-only | mandatory |
| airIRG3CMServiceIntervalsAirFilterInterval OBJECT-TYPE The CM service interval for air filter in weeks. Supported only for RA. Returns -1 if not supported. | 1.3.6.1.4.1.318.1.1.13.6.5.4.1.3 | INTEGER | read-write | mandatory |
| airIRG3CMServiceIntervalsAirFilterAlarm OBJECT-TYPE The CM service interval air filter alarm status. Supported only for RA. Returns -1 if not supported. | 1.3.6.1.4.1.318.1.1.13.6.5.4.1.4 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| airIRG3CMThresholdsTable OBJECT-TYPE Allows to access CM thresholds table. | 1.3.6.1.4.1.318.1.1.13.6.5.5 | not-accessible | mandatory | |
| airIRG3CMThresholdsEntry OBJECT-TYPE The CM thresholds table entry. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1 | not-accessible | mandatory | |
| airIRG3CMThresholdsDeviceIndex OBJECT-TYPE Index for CM thresholds table. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.1 | INTEGER | read-only | mandatory |
| airIRG3CMThresholdsCMID OBJECT-TYPE The CM ID (RDU Number - Group Number - CM Unit Number). | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.2 | DisplayString | read-only | mandatory |
| airIRG3CMThresholdsRackInletTempHighUS OBJECT-TYPE The CM high threshold for rack inlet temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.3 | INTEGER | read-write | mandatory |
| airIRG3CMThresholdsRackInletTempHighMetric OBJECT-TYPE The CM high threshold for rack inlet temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.4 | INTEGER | read-write | mandatory |
| airIRG3CMThresholdsSupplyAirTempHighUS OBJECT-TYPE The CM high threshold for supply air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.5 | INTEGER | read-write | mandatory |
| airIRG3CMThresholdsSupplyAirTempHighMetric OBJECT-TYPE The CM high threshold for supply air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.6 | INTEGER | read-write | mandatory |
| airIRG3CMThresholdsReturnAirTempHighUS OBJECT-TYPE The CM high threshold for return air temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.7 | INTEGER | read-write | mandatory |
| airIRG3CMThresholdsReturnAirTempHighMetric OBJECT-TYPE The CM high threshold for return air temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.13.6.5.5.1.8 | INTEGER | read-write | mandatory |
| airIRG3CMSetpointsTable OBJECT-TYPE Allows to access CM set points table. | 1.3.6.1.4.1.318.1.1.13.6.5.6 | not-accessible | mandatory | |
| airIRG3CMSetpointsEntry OBJECT-TYPE The CM set points table entry. | 1.3.6.1.4.1.318.1.1.13.6.5.6.1 | not-accessible | mandatory | |
| airIRG3CMSetpointsDeviceIndex OBJECT-TYPE Index of CM set points table. | 1.3.6.1.4.1.318.1.1.13.6.5.6.1.1 | INTEGER | read-only | mandatory |
| airIRG3CMConfigTable OBJECT-TYPE Allows to access CM configuration table. | 1.3.6.1.4.1.318.1.1.13.6.5.7 | not-accessible | mandatory | |
| airIRG3CMConfigEntry OBJECT-TYPE The CM configuration table entry. | 1.3.6.1.4.1.318.1.1.13.6.5.7.1 | not-accessible | mandatory | |
| airIRG3CMConfigDeviceIndex OBJECT-TYPE Index of CM configuration table. | 1.3.6.1.4.1.318.1.1.13.6.5.7.1.1 | INTEGER | read-only | mandatory |
| airIRG3CMConfigCMID OBJECT-TYPE The CM ID (RDU Number - Group Number - CM Unit Number). | 1.3.6.1.4.1.318.1.1.13.6.5.7.1.2 | DisplayString | read-only | mandatory |
| airIRG3CMConfigStopOnCoolFail OBJECT-TYPE Enable/Disable Stop On cool fail. When enabled, stops the unit if it detects that it is blowing warm air into the cold aisle. | 1.3.6.1.4.1.318.1.1.13.6.5.7.1.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| airIRG3CMConfigStartupDelay OBJECT-TYPE The CM start up delay in seconds. | 1.3.6.1.4.1.318.1.1.13.6.5.7.1.4 | INTEGER | read-write | mandatory |
| airIRG3CMConfigRemoteOnStandby OBJECT-TYPE The CM configuration for operating mode. | 1.3.6.1.4.1.318.1.1.13.6.5.7.1.5 | INTEGER {standBy(1), on(2)} | read-write | mandatory |
| airIRG3CMConfigPowerSource OBJECT-TYPE The CM power source. | 1.3.6.1.4.1.318.1.1.13.6.5.7.1.6 | INTEGER {singleFeed(1), dualFeed(2)} | read-write | mandatory |
| rARU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14 | |||
| rARUIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14.1 | |||
| rARUIdentTable OBJECT-TYPE Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID. | 1.3.6.1.4.1.318.1.1.14.1.1 | not-accessible | mandatory | |
| rARUIdentEntry OBJECT-TYPE The device to query. | 1.3.6.1.4.1.318.1.1.14.1.1.1 | not-accessible | mandatory | |
| rARUIdentAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.1.1.1.1 | INTEGER | read-only | mandatory |
| rARUIdentName OBJECT-TYPE A character string identifying the device. | 1.3.6.1.4.1.318.1.1.14.1.1.1.2 | DisplayString | read-only | mandatory |
| rARUConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14.2 | |||
| rARUConfigTable OBJECT-TYPE Allows for configuration of the individual ARU devices accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID. | 1.3.6.1.4.1.318.1.1.14.2.1 | not-accessible | mandatory | |
| rARUConfigEntry OBJECT-TYPE The ARUs to configure. | 1.3.6.1.4.1.318.1.1.14.2.1.1 | not-accessible | mandatory | |
| rARUConfigAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.2.1.1.1 | INTEGER | read-only | mandatory |
| rARUConfigAruName OBJECT-TYPE The name of the ARU. | 1.3.6.1.4.1.318.1.1.14.2.1.1.2 | DisplayString | read-write | mandatory |
| rARUConfigAruRemoteSetpoint OBJECT-TYPE This OID defines the desired base airflow of the ARU, and sets the speed of the ARU fans when the temperature override is inactive. Values specified in cfm (cubic feet per minute) can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour). Values (1) through (9) are for support of legacy (1st generation) ARUs. Writing these values to a 2nd generation ARU will result in the following: A value greater than (9) will be ignored by a 1st generation ARU. aruOff (1) - Ignored aru85F-29C (2) - 1200 cfm aru90F-32C (3) - 800 cfm aru95F-35C (4) - 500 cfm aru100F-38C (5) - 400 cfm aru7kW (6) - 1200 cfm aru5kW (7) - 800 cfm aru3kW (8) - 500 cfm aru2kW (9) - 400 cfm NOTE: -1 will be returned if the ARU is not communicating. | 1.3.6.1.4.1.318.1.1.14.2.1.1.3 | INTEGER {aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW-1200cfm(6), aru5kW-800cfm(7), aru3kW-500cfm(8), aru2kW-300cfm(9), aru400cfm(10), aru600cfm(11), aru700cfm(12), aru900cfm(13), aru1000cfm(14), aru1400cfm(15), aru1600cfm(16), aru1800cfm(17), aru2000cfm(18)} | read-write | mandatory |
| rARUConfigAruTempOvrdEnableDisable OBJECT-TYPE This OID is used to enable/disable the remote temperature override setting of the ARU. If this OID is set to 1, the remote setting for temperature override is disabled. If this OID is set to 2, the remote setting for temperature override is enabled. | 1.3.6.1.4.1.318.1.1.14.2.1.1.4 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| rARUConfigAruTempOvrdSetpoint OBJECT-TYPE This OID is the Temperature Override setpoint of the ARU. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees using the units specified in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.14.2.1.1.5 | INTEGER | read-write | mandatory |
| rARUConfigAruMasterControl OBJECT-TYPE This is the master on/off control for the ARU. | 1.3.6.1.4.1.318.1.1.14.2.1.1.6 | INTEGER {aruOn(1), aruOff(2)} | read-write | mandatory |
| rARUStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14.3 | |||
| rARUStatusAruDeviceCount OBJECT-TYPE The total number of ARUs accessible from this IP. | 1.3.6.1.4.1.318.1.1.14.3.1 | INTEGER | read-only | mandatory |
| rARUStatusSysTempUnits OBJECT-TYPE The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. | 1.3.6.1.4.1.318.1.1.14.3.2 | INTEGER {celsius(1), fahrenheit(2)} | read-only | mandatory |
| rARUStatusTable OBJECT-TYPE Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID. | 1.3.6.1.4.1.318.1.1.14.3.3 | not-accessible | mandatory | |
| rARUStatusEntry OBJECT-TYPE The ARUs to access. | 1.3.6.1.4.1.318.1.1.14.3.3.1 | not-accessible | mandatory | |
| rARUStatusAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.3.3.1.1 | INTEGER | read-only | mandatory |
| rARUStatusAruName OBJECT-TYPE The name of the ARU. | 1.3.6.1.4.1.318.1.1.14.3.3.1.2 | DisplayString | read-only | mandatory |
| rARUStatusAruRemoteSetpoint OBJECT-TYPE This OID defines the desired base airflow of the ARU, or the speed of the ARU fans when the temperature override is inactive. See also the rARUConfigAruRemoteSetpoint OID. NOTE: -1 will be returned if the ARU is not communicating. | 1.3.6.1.4.1.318.1.1.14.3.3.1.3 | INTEGER {aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW-1200cfm(6), aru5kW-800cfm(7), aru3kW-500cfm(8), aru2kW-300cfm(9), aru400cfm(10), aru600cfm(11), aru700cfm(12), aru900cfm(13), aru1000cfm(14), aru1400cfm(15), aru1600cfm(16), aru1800cfm(17), aru2000cfm(18)} | read-only | mandatory |
| rARUStatusAruManualSetpoint OBJECT-TYPE Manual operating setpoint of the ARU, which is set on the panel of the ARU. If the ARU doesn't have a manual , the OID will always return a value of aruRem (10). NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees or kW. If the manual setpoint is set to Remote, or if the ARU doesn't have a manual switch, this OID will return aruRem. | 1.3.6.1.4.1.318.1.1.14.3.3.1.4 | INTEGER {aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW(6), aru5kW(7), aru3kW(8), aru2kW(9), aruRem(10)} | read-only | mandatory |
| rARUStatusAruTemp1 OBJECT-TYPE ARU temperature probe #1 reading. The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.14.3.3.1.5 | INTEGER | read-only | mandatory |
| rARUStatusAruTemp2 OBJECT-TYPE ARU temperature probe #2 reading. The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.14.3.3.1.6 | INTEGER | read-only | mandatory |
| rARUStatusAruTemp3 OBJECT-TYPE ARU temperature probe #3 reading. The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.14.3.3.1.7 | INTEGER | read-only | mandatory |
| rARUStatusAruTempOvrdEnableDisable OBJECT-TYPE This OID indicates whether the ARU remote temperature override is enabled or disabled. If this OID is a 1, the remote setting for temperature override is disabled. If this OID is a 2, the remote setting for temperature override is enabled. | 1.3.6.1.4.1.318.1.1.14.3.3.1.8 | INTEGER {disabled(1), enabled(2)} | read-only | mandatory |
| rARUStatusAruTempOvrdSetpoint OBJECT-TYPE ARU remote temperature override setpoint setting. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit). | 1.3.6.1.4.1.318.1.1.14.3.3.1.9 | INTEGER | read-only | mandatory |
| rARUStatusAruAlarmState OBJECT-TYPE An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 8, read from left to right. The flags are defined as follows: Flag 1: Fan Fail 1 Flag 2: Fan Fail 2 Flag 3: Fan Fail 3 Flag 4: Smoke (if ARU is equipped with smoke detector) Flag 5: High Temp (Out of Thermal Control) Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint) Flag 7: Fan Fail 4 (Gen 2 ARU only) Flag 8: Reserved | 1.3.6.1.4.1.318.1.1.14.3.3.1.10 | DisplayString | read-only | mandatory |
| rARUStatusAruCommStatus OBJECT-TYPE The state of communications to the device. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no device. | 1.3.6.1.4.1.318.1.1.14.3.3.1.11 | INTEGER {commsNeverDiscovered(1), commsEstablished(2), commsLost(3)} | read-only | mandatory |
| rARUStatusAruTempOvrdStatus OBJECT-TYPE Specifies whether the ARU is increasing airflow because exhaust air temperature has exceeded the setting specified in the rARUConfigAruTempOvrdSetpoint OID. | 1.3.6.1.4.1.318.1.1.14.3.3.1.12 | INTEGER {inactive(1), active(2)} | read-only | mandatory |
| rARUStatusAruMasterControl OBJECT-TYPE This is the master on/off control for the ARU. | 1.3.6.1.4.1.318.1.1.14.3.3.1.13 | INTEGER {aruOn(1), aruOff(2)} | read-only | mandatory |
| rARUStatusAruTotalAirflow OBJECT-TYPE The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour). | 1.3.6.1.4.1.318.1.1.14.3.3.1.14 | INTEGER | read-only | mandatory |
| rARUFanStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14.4 | |||
| rARUFanStatusTable OBJECT-TYPE Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID. | 1.3.6.1.4.1.318.1.1.14.4.1 | not-accessible | mandatory | |
| rARUFanStatusEntry OBJECT-TYPE The device to query. | 1.3.6.1.4.1.318.1.1.14.4.1.1 | not-accessible | mandatory | |
| rARUFanStatusAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.4.1.1.1 | INTEGER | read-only | mandatory |
| rARUFanStatusNominalFanSpeed OBJECT-TYPE The nominal rotational speed (RPM) of the fans when they are operating at the 100% level. | 1.3.6.1.4.1.318.1.1.14.4.1.1.2 | INTEGER | read-only | mandatory |
| rARUFanStatusSelectedFanLevel OBJECT-TYPE The currently selected ARU speed level, specified in percent of full capacity. | 1.3.6.1.4.1.318.1.1.14.4.1.1.3 | INTEGER | read-only | mandatory |
| rARUFanStatusReplacementThreshold OBJECT-TYPE Threshold above which a run hour alarm will exist, indicating that it might be time to proactively replace a fan. | 1.3.6.1.4.1.318.1.1.14.4.1.1.4 | INTEGER {disabled(1), khr20(2), khr25(3), khr30(4), khr35(5), khr40(6), khr50(7)} | read-write | mandatory |
| rARUFanStatusFanIndex OBJECT-TYPE The index to an individual fan table entry. | 1.3.6.1.4.1.318.1.1.14.4.1.1.5 | INTEGER | read-only | mandatory |
| rARUFanStatusFanOperatingStatus OBJECT-TYPE The current operating state of the fan. | 1.3.6.1.4.1.318.1.1.14.4.1.1.6 | INTEGER {unknown(1), off(2), onOk(3), onDegraded(4), offFailed(5)} | read-only | mandatory |
| rARUFanStatusFanRpmSpeed OBJECT-TYPE The current rotational speed of the fan, specified in rotations per minute (RPM). | 1.3.6.1.4.1.318.1.1.14.4.1.1.7 | INTEGER | read-only | mandatory |
| rARUFanStatusFanFlowRate OBJECT-TYPE The flow rate provided by the fan, based on its measured rotational speed. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour). | 1.3.6.1.4.1.318.1.1.14.4.1.1.8 | INTEGER | read-only | mandatory |
| rARUFanStatusFanInServiceDate OBJECT-TYPE The installation/replacement date of the fan. | 1.3.6.1.4.1.318.1.1.14.4.1.1.9 | DisplayString | read-write | mandatory |
| rARUFanStatusFanRunhourCounter OBJECT-TYPE The total time for which the fan has been running. Specified in 10ths of hours. | 1.3.6.1.4.1.318.1.1.14.4.1.1.10 | INTEGER | read-only | mandatory |
| rARUFanStatusFanRunhourReset OBJECT-TYPE Writing yes to this This OID will reset a fan's total run hour counter, which is shown in the rARUFanStatusFanRunhourCounter OID. | 1.3.6.1.4.1.318.1.1.14.4.1.1.11 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| rARUPower OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14.5 | |||
| rARUPowerStatusTable OBJECT-TYPE Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID. | 1.3.6.1.4.1.318.1.1.14.5.1 | not-accessible | mandatory | |
| rARUPowerStatusEntry OBJECT-TYPE The device to query. | 1.3.6.1.4.1.318.1.1.14.5.1.1 | not-accessible | mandatory | |
| rARUPowerStatusAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.5.1.1.1 | INTEGER | read-only | mandatory |
| rARUPowerStatusPrimaryAcPresent OBJECT-TYPE Indicates whether or not line voltage is present on AC input 1. | 1.3.6.1.4.1.318.1.1.14.5.1.1.2 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| rARUPowerStatusAuxiliaryAcPresent OBJECT-TYPE Indicates whether or not line voltage is present on AC input 2. | 1.3.6.1.4.1.318.1.1.14.5.1.1.3 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| rARUPowerStatusRedundantAcConfig OBJECT-TYPE Indicates whether or not a dual cord is in use. When this setting is set to dualCord (2), aruRedundantPowerLostAlarm traps will be generated when either primary or auxiliary input voltage is not present. When this setting is set to singleCord (1), aruRedundantPowerLostAlarm traps will not be generated. | 1.3.6.1.4.1.318.1.1.14.5.1.1.4 | INTEGER {singleCord(1), dualCord(2)} | read-write | mandatory |
| rARUSensors OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.14.6 | |||
| rARUSensorsStatusTableSize OBJECT-TYPE The number of entries in the rARUSensorsStatusTable. | 1.3.6.1.4.1.318.1.1.14.6.1 | INTEGER | read-only | mandatory |
| rARUSensorsStatusTable OBJECT-TYPE Allows for getting environmental sensor status information. | 1.3.6.1.4.1.318.1.1.14.6.2 | not-accessible | mandatory | |
| rARUSensorsStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.14.6.2.1 | not-accessible | mandatory | |
| rARUSensorsStatusAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.6.2.1.1 | INTEGER | read-only | mandatory |
| rARUSensorsStatusSensorNumber OBJECT-TYPE The number of the sensor on the device. | 1.3.6.1.4.1.318.1.1.14.6.2.1.2 | INTEGER | read-only | mandatory |
| rARUSensorsTemperature OBJECT-TYPE The sensor's current temperature reading. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.2.1.3 | INTEGER | read-only | mandatory |
| rARUSensorsConfigTableSize OBJECT-TYPE The number of entries in the rARUSensorsConfigTable. | 1.3.6.1.4.1.318.1.1.14.6.3 | INTEGER | read-only | mandatory |
| rARUSensorsConfigTable OBJECT-TYPE Allows for getting configuration information from environmental sensors attached to the device. | 1.3.6.1.4.1.318.1.1.14.6.4 | not-accessible | mandatory | |
| rARUSensorsConfigEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.14.6.4.1 | not-accessible | mandatory | |
| rARUSensorsConfigAruIndex OBJECT-TYPE The index to the ARU entry. | 1.3.6.1.4.1.318.1.1.14.6.4.1.1 | INTEGER | read-only | mandatory |
| rARUSensorsConfigSensorNumber OBJECT-TYPE The number of the sensor on the device. | 1.3.6.1.4.1.318.1.1.14.6.4.1.2 | INTEGER | read-only | mandatory |
| rARUSensorsName OBJECT-TYPE A descriptive name for the sensor. | 1.3.6.1.4.1.318.1.1.14.6.4.1.3 | DisplayString | read-write | mandatory |
| rARUSensorsLocation OBJECT-TYPE The location of the sensor. | 1.3.6.1.4.1.318.1.1.14.6.4.1.4 | DisplayString | read-write | mandatory |
| rARUSensorsTempMaxThresh OBJECT-TYPE The temperature at which a maximum temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.5 | INTEGER | read-write | mandatory |
| rARUSensorsTempHighThresh OBJECT-TYPE The temperature at which a high temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.6 | INTEGER | read-write | mandatory |
| rARUSensorsTempLowThresh OBJECT-TYPE The temperature at which a low temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.7 | INTEGER | read-write | mandatory |
| rARUSensorsTempMinThresh OBJECT-TYPE The temperature at which a min temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.8 | INTEGER | read-write | mandatory |
| rARUSensorsTempThreshHysteresis OBJECT-TYPE The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.9 | INTEGER | read-write | mandatory |
| rARUSensorsTempShortDecRateThreshValue OBJECT-TYPE The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.10 | INTEGER | read-write | mandatory |
| rARUSensorsTempShortDecRateThreshTime OBJECT-TYPE The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value. | 1.3.6.1.4.1.318.1.1.14.6.4.1.11 | INTEGER | read-write | mandatory |
| rARUSensorsTempShortIncRateThreshValue OBJECT-TYPE The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.12 | INTEGER | read-write | mandatory |
| rARUSensorsTempShortIncRateThreshTime OBJECT-TYPE The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value. | 1.3.6.1.4.1.318.1.1.14.6.4.1.13 | INTEGER | read-write | mandatory |
| rARUSensorsTempLongDecRateThreshValue OBJECT-TYPE The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.14 | INTEGER | read-write | mandatory |
| rARUSensorsTempLongDecRateThreshTime OBJECT-TYPE The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value. | 1.3.6.1.4.1.318.1.1.14.6.4.1.15 | INTEGER | read-write | mandatory |
| rARUSensorsTempLongIncRateThreshValue OBJECT-TYPE The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. | 1.3.6.1.4.1.318.1.1.14.6.4.1.16 | INTEGER | read-write | mandatory |
| rARUSensorsTempLongIncRateThreshTime OBJECT-TYPE The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value. | 1.3.6.1.4.1.318.1.1.14.6.4.1.17 | INTEGER | read-write | mandatory |
| xPDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15 | |||
| xPDUIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.1 | |||
| xPDUIdentProductName OBJECT-TYPE The name of the PDU. | 1.3.6.1.4.1.318.1.1.15.1.1 | DisplayString | read-write | mandatory |
| xPDUIdentHardwareRev OBJECT-TYPE The hardware revision of the PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.15.1.2 | DisplayString | read-only | mandatory |
| xPDUIdentFirmwareAppRev OBJECT-TYPE An ID string identifying the application firmware revision of the PDU. | 1.3.6.1.4.1.318.1.1.15.1.3 | DisplayString | read-only | mandatory |
| xPDUIdentFirmwareAppOSRev OBJECT-TYPE An ID string identifying the application operating system firmware revision of the PDU. | 1.3.6.1.4.1.318.1.1.15.1.4 | DisplayString | read-only | mandatory |
| xPDUIdentFirmwareControllerRev OBJECT-TYPE An ID string identifying the PDU controller firmware revision. | 1.3.6.1.4.1.318.1.1.15.1.5 | DisplayString | read-only | mandatory |
| xPDUIdentDateOfManufacture OBJECT-TYPE The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.15.1.6 | DisplayString | read-only | mandatory |
| xPDUIdentModelNumber OBJECT-TYPE A character string identifying the model number of the PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.15.1.7 | DisplayString | read-only | mandatory |
| xPDUIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.15.1.8 | DisplayString | read-only | mandatory |
| xPDUDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.2 | |||
| xPDUDeviceNominalMainInputVoltage OBJECT-TYPE The nominal main input voltage to the PDU. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. | 1.3.6.1.4.1.318.1.1.15.2.1 | INTEGER | read-only | mandatory |
| xPDUDeviceServiceType OBJECT-TYPE The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye). | 1.3.6.1.4.1.318.1.1.15.2.2 | INTEGER {threeWire(1), fourWire(2)} | read-only | mandatory |
| xPDUDeviceNominalOutputVoltage OBJECT-TYPE The nominal line-to-neutral output voltage to the load measured in Volts. | 1.3.6.1.4.1.318.1.1.15.2.3 | INTEGER | read-only | mandatory |
| xPDUDeviceMainInputBreakerRating OBJECT-TYPE The rating of the main input breaker measured in Amps. | 1.3.6.1.4.1.318.1.1.15.2.4 | INTEGER | read-only | mandatory |
| xPDUDevicePanelBreakerRating OBJECT-TYPE The rating of the panel breaker measured in Amps. | 1.3.6.1.4.1.318.1.1.15.2.5 | INTEGER | read-only | mandatory |
| xPDUDeviceTransformerPresent OBJECT-TYPE Indicates whether or not a transformer is installed in the PDU. | 1.3.6.1.4.1.318.1.1.15.2.6 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceLoadTieBreakerPresent OBJECT-TYPE Indicates whether or not a load tie breaker is installed in the PDU. | 1.3.6.1.4.1.318.1.1.15.2.7 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceLoadTestPortPresent OBJECT-TYPE Indicates whether or not a load test port is installed in the PDU. | 1.3.6.1.4.1.318.1.1.15.2.8 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceFusesPresent OBJECT-TYPE Indicates whether or not the UPS feed from the PDU includes fuses. | 1.3.6.1.4.1.318.1.1.15.2.9 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceFansPresent OBJECT-TYPE Indicates whether or not cooling fans are installed in the PDU. | 1.3.6.1.4.1.318.1.1.15.2.10 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceBypassInputPresent OBJECT-TYPE Indicates whether or not the PDU is equipped with a second feed for the UPS's bypass input. | 1.3.6.1.4.1.318.1.1.15.2.11 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceCrossTieOutputPresent OBJECT-TYPE Indicates whether or not the PDU is equipped with a cross-tie output. | 1.3.6.1.4.1.318.1.1.15.2.12 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceEarthGroundMonitorPresent OBJECT-TYPE Indicates whether or not the PDU can provide ground current measurements. | 1.3.6.1.4.1.318.1.1.15.2.13 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| xPDUDeviceInfraStruXureType OBJECT-TYPE Indicates the configuration of this PDU system. Type-B PDU is in a distributed UPS system and has bypass capabilities. Type-C PDU receives power from a larger central UPS. | 1.3.6.1.4.1.318.1.1.15.2.14 | INTEGER {typeB(1), typeC(2)} | read-only | mandatory |
| xPDUACMonitoringPoint OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.3 | |||
| xPDUMainInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.3.1 | |||
| xPDUMainInputOverVoltThreshold OBJECT-TYPE Threshold above which an input over voltage condition will be generated. Specified as percent deviation from nominal. | 1.3.6.1.4.1.318.1.1.15.3.1.1 | INTEGER (0..30) | read-write | mandatory |
| xPDUMainInputUnderVoltThreshold OBJECT-TYPE Threshold below which an input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.15.3.1.2 | INTEGER (0..30) | read-write | mandatory |
| xPDUMainInputVoltageTableSize OBJECT-TYPE The number of Main input voltage entries. | 1.3.6.1.4.1.318.1.1.15.3.1.3 | INTEGER | read-only | mandatory |
| xPDUMainInputVoltagePhaseTable OBJECT-TYPE A list of input voltage table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUMainInputVoltageTableSize OID. | 1.3.6.1.4.1.318.1.1.15.3.1.4 | not-accessible | mandatory | |
| xPDUMainInputVoltagePhaseEntry OBJECT-TYPE An entry containing information applicable to a particular main input voltage phase. | 1.3.6.1.4.1.318.1.1.15.3.1.4.1 | not-accessible | mandatory | |
| xPDUMainInputVoltagePhaseIndex OBJECT-TYPE Description of each input phase entry in the table. | 1.3.6.1.4.1.318.1.1.15.3.1.4.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xPDUMainInputVoltageLtoL OBJECT-TYPE Line-to-line PDU input voltage when an isolation transformer is present, or -1 if no transformer present in this PDU. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.15.3.1.4.1.2 | INTEGER | read-only | mandatory |
| xPDUMainInputVoltageLtoN OBJECT-TYPE Line-to-neutral PDU input voltage when an isolation transformer is not present, or -1 if a transformer is present in this PDU. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.15.3.1.4.1.3 | INTEGER | read-only | mandatory |
| xPDUBypassInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.3.2 | |||
| xPDUBypassInputOverVoltThreshold OBJECT-TYPE Threshold above which a bypass input over voltage condition will be generated. Specified as percent deviation from nominal. | 1.3.6.1.4.1.318.1.1.15.3.2.1 | INTEGER (0..30) | read-write | mandatory |
| xPDUBypassInputUnderVoltThreshold OBJECT-TYPE Threshold below which an bypass input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.15.3.2.2 | INTEGER (0..30) | read-write | mandatory |
| xPDUBypassInputVoltagePhaseTableSize OBJECT-TYPE The number of bypass input voltage entries. | 1.3.6.1.4.1.318.1.1.15.3.2.3 | INTEGER | read-only | mandatory |
| xPDUBypassInputVoltagePhaseTable OBJECT-TYPE A list of output table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUBypassInputVoltagePhaseTableSize OID. | 1.3.6.1.4.1.318.1.1.15.3.2.4 | not-accessible | mandatory | |
| xPDUBypassInputVoltagePhaseEntry OBJECT-TYPE An entry containing information applicable to a particular bypass input voltage phase. | 1.3.6.1.4.1.318.1.1.15.3.2.4.1 | not-accessible | mandatory | |
| xPDUBypassInputVoltagePhaseIndex OBJECT-TYPE Index of each bypass input phase entry in the table. | 1.3.6.1.4.1.318.1.1.15.3.2.4.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xPDUBypassInputVoltageLtoL OBJECT-TYPE Line-to-line bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.15.3.2.4.1.2 | INTEGER | read-only | mandatory |
| xPDUBypassInputVoltageLtoN OBJECT-TYPE Line-to-neutral bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.15.3.2.4.1.3 | INTEGER | read-only | mandatory |
| xPDUUPSInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.3.3 | |||
| xPDUUPSInputVoltagePhaseTableSize OBJECT-TYPE The number of UPS input voltage entries. | 1.3.6.1.4.1.318.1.1.15.3.3.1 | INTEGER | read-only | mandatory |
| xPDUUPSInputVoltagePhaseTable OBJECT-TYPE A list of UPS input table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUUPSInputVoltagePhaseTableSize OID. | 1.3.6.1.4.1.318.1.1.15.3.3.2 | not-accessible | mandatory | |
| xPDUUPSInputVoltagePhaseEntry OBJECT-TYPE An entry containing information applicable to a particular UPS input voltage phase. | 1.3.6.1.4.1.318.1.1.15.3.3.2.1 | not-accessible | mandatory | |
| xPDUUPSInputVoltagePhaseIndex OBJECT-TYPE Description of each UPS input phase entry in the table. | 1.3.6.1.4.1.318.1.1.15.3.3.2.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xPDUUPSInputVoltageLtoNPresent OBJECT-TYPE Indicates whether or not voltage is present at the UPS feed. | 1.3.6.1.4.1.318.1.1.15.3.3.2.1.2 | INTEGER {notPresent(1), present(2), unknown(3)} | read-only | mandatory |
| xPDUSystemOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.3.4 | |||
| xPDUSystemOutputFrequency OBJECT-TYPE The system output frequency in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.15.3.4.1 | INTEGER | read-only | mandatory |
| xPDUSystemOutputNeutralCurrent OBJECT-TYPE Shows the neutral current measured at the system output in tenths of Amps. | 1.3.6.1.4.1.318.1.1.15.3.4.2 | INTEGER | read-only | mandatory |
| xPDUSystemOutputTotalPower OBJECT-TYPE Shows the total system output power in tenths of kW. | 1.3.6.1.4.1.318.1.1.15.3.4.3 | INTEGER | read-only | mandatory |
| xPDUSystemOutputTotalApparentPower OBJECT-TYPE Shows the total system output power in tenths of kVA. | 1.3.6.1.4.1.318.1.1.15.3.4.4 | INTEGER | read-only | mandatory |
| xPDUSystemOutputTotalPowerFactor OBJECT-TYPE Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00). Measured in hundredths. | 1.3.6.1.4.1.318.1.1.15.3.4.5 | INTEGER | read-only | mandatory |
| xPDUSystemOutputFrequencyTolerance OBJECT-TYPE Shows the circuit panel output frequency tolerance in Hertz. | 1.3.6.1.4.1.318.1.1.15.3.4.6 | INTEGER {freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10)} | read-write | mandatory |
| xPDUSystemOutputMaxKWPower OBJECT-TYPE Defines 100% load in kW. Purpose is to set to match UPS capabilities. | 1.3.6.1.4.1.318.1.1.15.3.4.7 | INTEGER | read-write | mandatory |
| xPDUSystemOutputOverVoltThreshold OBJECT-TYPE Threshold above which an output over voltage condition will be generated. Specified as percent deviation from nominal. | 1.3.6.1.4.1.318.1.1.15.3.4.8 | INTEGER (0..30) | read-write | mandatory |
| xPDUSystemOutputUnderVoltThreshold OBJECT-TYPE Threshold below which an output under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.15.3.4.9 | INTEGER (0..30) | read-write | mandatory |
| xPDUSystemOutputOverCurrentThreshold OBJECT-TYPE Threshold above which an over current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.15.3.4.10 | INTEGER (0..110) | read-write | mandatory |
| xPDUSystemOutputOverCurrentNeutralThreshold OBJECT-TYPE Threshold above which an Over current neutral condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.15.3.4.11 | INTEGER (0..110) | read-write | mandatory |
| xPDUSystemOutputUnderCurrentThreshold OBJECT-TYPE Threshold below which an under current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.15.3.4.12 | INTEGER (0..100) | read-write | mandatory |
| xPDUSystemOutputTableSize OBJECT-TYPE The number of System Output phase entries. | 1.3.6.1.4.1.318.1.1.15.3.4.13 | INTEGER | read-only | mandatory |
| xPDUSystemOutputPhaseTable OBJECT-TYPE A list of system output table entries. The number of entries is contained in the xPDUSystemOutputTableSize OID. | 1.3.6.1.4.1.318.1.1.15.3.4.14 | not-accessible | mandatory | |
| xPDUSystemOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular system output phase. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1 | not-accessible | mandatory | |
| xPDUSystemOutputPhaseIndex OBJECT-TYPE Description of each output phase entry in the table. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xPDUSystemOutputVoltageLtoL OBJECT-TYPE Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.2 | INTEGER | read-only | mandatory |
| xPDUSystemOutputVoltageLtoN OBJECT-TYPE Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.3 | INTEGER | read-only | mandatory |
| xPDUSystemOutputPhaseCurrent OBJECT-TYPE System load current per phase. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.4 | INTEGER | read-only | mandatory |
| xPDUSystemOutputPower OBJECT-TYPE System output power per phase. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.5 | INTEGER | read-only | mandatory |
| xPDUSystemOutputApparentPower OBJECT-TYPE System output power per phase. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.6 | INTEGER | read-only | mandatory |
| xPDUSystemOutputPowerFactor OBJECT-TYPE Indicates the Power Factor of the system output per phase. A value of 100 representing a unity Power Factor (1.00). Measured in hundredths. | 1.3.6.1.4.1.318.1.1.15.3.4.14.1.7 | INTEGER | read-only | mandatory |
| xPDUGroundMonitorPoint OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.3.5 | |||
| xPDUGroundCurrent OBJECT-TYPE Shows the current measured in the earth ground conductor. Measured in tenths of Amps, or -1 if not available. | 1.3.6.1.4.1.318.1.1.15.3.5.1 | INTEGER | read-only | mandatory |
| xPDUGroundCurrentThreshold OBJECT-TYPE Threshold above which a ground current over current condition will be generated. Specified in tenths of Amps. | 1.3.6.1.4.1.318.1.1.15.3.5.2 | INTEGER (0..50) | read-write | mandatory |
| xPDUCircuitBreakers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.4 | |||
| xPDUSystemBreakers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.4.1 | |||
| xPDUSystemBreakerTableSize OBJECT-TYPE The number of system breaker entries. | 1.3.6.1.4.1.318.1.1.15.4.1.1 | INTEGER | read-only | mandatory |
| xPDUSystemBreakerTable OBJECT-TYPE A list of system breaker entries. The number of entries is contained in the xPDUSystemBreakerTableSize OID. | 1.3.6.1.4.1.318.1.1.15.4.1.2 | not-accessible | mandatory | |
| xPDUSystemBreakerEntry OBJECT-TYPE An entry containing information applicable to a particular system breaker. | 1.3.6.1.4.1.318.1.1.15.4.1.2.1 | not-accessible | mandatory | |
| xPDUSystemBreakerTableIndex OBJECT-TYPE Index of system breaker entries in the table. | 1.3.6.1.4.1.318.1.1.15.4.1.2.1.1 | INTEGER | read-only | mandatory |
| xPDUSystemBreakerDescription OBJECT-TYPE A brief description of the system breakers. | 1.3.6.1.4.1.318.1.1.15.4.1.2.1.2 | DisplayString (SIZE(0..79)) | read-only | mandatory |
| xPDUSystemBreakerPosition OBJECT-TYPE Indicates whether this breaker is open(1) or closed(2). | 1.3.6.1.4.1.318.1.1.15.4.1.2.1.3 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| xPDUBranchBreakers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.4.2 | |||
| xPDUNumOfBranchBreakers OBJECT-TYPE The number of branch breakers (panel positions) in the Panel. returns 42 for a 1-panel or 84 for a 2-panel system. | 1.3.6.1.4.1.318.1.1.15.4.2.1 | INTEGER | read-only | mandatory |
| xPDUBranchBreakerTableSize OBJECT-TYPE The number of branch breaker entries determined by the xPDUNumOfBranchBreakers OID. | 1.3.6.1.4.1.318.1.1.15.4.2.2 | INTEGER | read-only | mandatory |
| xPDUBranchBreakerTable OBJECT-TYPE A list of branch breaker table entries. The number of entries is given by the value of xPDUBranchBreakerTableSize The number of entries is contained in the xPDUBranchBreakerTableSize OID. | 1.3.6.1.4.1.318.1.1.15.4.2.3 | not-accessible | mandatory | |
| xPDUBranchBreakerEntry OBJECT-TYPE An entry containing information applicable to a particular branch breaker (panel position). | 1.3.6.1.4.1.318.1.1.15.4.2.3.1 | not-accessible | mandatory | |
| xPDUBranchBreakerTableIndex OBJECT-TYPE Index of branch breaker entries in the table. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.1 | INTEGER | read-only | mandatory |
| xPDUBranchBreakerRating OBJECT-TYPE Indicates current rating of this breaker. 0=Breaker is not present. 1=Earth leakage connection. 2=Neutral connection. A value greater than 2 indicates breaker current rating in Amps. A value above 60 Amp will signify a remote feed. The xPDUBranchBreakerRDPFeed OID will indicate which breakers are configured as a remote drop. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.2 | INTEGER | read-write | mandatory |
| xPDUBranchBreakerRDPFeed OBJECT-TYPE Indicates that a breaker position is feeding a remote distribution panel. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.3 | INTEGER {remoteDistribution(1), noRemoteDistribution(2)} | read-only | mandatory |
| xPDUBranchBreakerTieIndicator OBJECT-TYPE Indicates whether or not the breaker in this position is logically associated with the breaker immediately below it. This setting is used grouping the breakers feeding a multi-pole branch circuit. Note: When setting an entry's branch breaker tie indicator to breakerTied, all the positions that are tied to this breaker will take on the rating and thresholds for this entry of the table. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.4 | INTEGER {breakerUnTied(1), breakerTied(2)} | read-write | mandatory |
| xPDUBranchBreakerCurrent OBJECT-TYPE Indicates the branch current in tenths of Amps or -1 when not available. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.5 | INTEGER | read-only | mandatory |
| xPDUBranchBreakerOverCurrentThreshold OBJECT-TYPE Threshold above which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.6 | INTEGER (0..100) | read-write | mandatory |
| xPDUBranchBreakerUnderCurrentThreshold OBJECT-TYPE Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.7 | INTEGER (0..100) | read-write | mandatory |
| xPDUBranchBreakerMaxCurrentThreshold OBJECT-TYPE Threshold above which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.8 | INTEGER (0..100) | read-write | mandatory |
| xPDUBranchBreakerMinCurrentThreshold OBJECT-TYPE Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.9 | INTEGER (0..100) | read-write | mandatory |
| xPDUBranchBreakerName OBJECT-TYPE The description of the purpose/use of the breaker. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.10 | DisplayString | read-write | mandatory |
| xPDUBranchBreakerLocation OBJECT-TYPE The description of the location of the breaker. | 1.3.6.1.4.1.318.1.1.15.4.2.3.1.11 | DisplayString | read-write | mandatory |
| xPDUInputContacts OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.5 | |||
| xPDUInputContactNumContacts OBJECT-TYPE The number of contacts supported by the PDU. | 1.3.6.1.4.1.318.1.1.15.5.1 | INTEGER | read-only | mandatory |
| xPDUInputContactTableSize OBJECT-TYPE The number of input contact entries. | 1.3.6.1.4.1.318.1.1.15.5.2 | INTEGER | read-only | mandatory |
| xPDUInputContactTable OBJECT-TYPE A list of contacts supported by the PDU. The number of entries is contained in the xPDUInputContactTableSize OID. | 1.3.6.1.4.1.318.1.1.15.5.3 | not-accessible | mandatory | |
| xPDUInputContactEntry OBJECT-TYPE A contact entry containing information for a given contact. | 1.3.6.1.4.1.318.1.1.15.5.3.1 | not-accessible | mandatory | |
| xPDUInputContactNumber OBJECT-TYPE An index identifying the contact on the PDU. | 1.3.6.1.4.1.318.1.1.15.5.3.1.1 | INTEGER | read-only | mandatory |
| xPDUInputContactName OBJECT-TYPE The description of the purpose/use of the contact. | 1.3.6.1.4.1.318.1.1.15.5.3.1.2 | DisplayString | read-write | mandatory |
| xPDUInputContactNormalState OBJECT-TYPE The normal operating position of the contact. | 1.3.6.1.4.1.318.1.1.15.5.3.1.3 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| xPDUInputContactCurrentState OBJECT-TYPE This value indicates the current state of the contact. | 1.3.6.1.4.1.318.1.1.15.5.3.1.4 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| xPDUOutputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.6 | |||
| xPDUOutputRelaysNumRelays OBJECT-TYPE The number of output relays supported by the PDU. | 1.3.6.1.4.1.318.1.1.15.6.1 | INTEGER | read-only | mandatory |
| xPDUOutputRelaysTableSize OBJECT-TYPE The number of output relay entries. | 1.3.6.1.4.1.318.1.1.15.6.2 | INTEGER | read-only | mandatory |
| xPDUOutputRelayTable OBJECT-TYPE A list of output relays supported by the PDU. The number of entries is contained in the xPDUOutputRelayTableSize OID. | 1.3.6.1.4.1.318.1.1.15.6.3 | not-accessible | mandatory | |
| xPDUOutputRelayEntry OBJECT-TYPE A output relay entry containing information for a given contact. | 1.3.6.1.4.1.318.1.1.15.6.3.1 | not-accessible | mandatory | |
| xPDUOutputRelayNumber OBJECT-TYPE An index identifying the output relay on the PDU. | 1.3.6.1.4.1.318.1.1.15.6.3.1.1 | INTEGER | read-only | mandatory |
| xPDUOutputRelayName OBJECT-TYPE The description of the purpose/use of the output relay. | 1.3.6.1.4.1.318.1.1.15.6.3.1.2 | DisplayString | read-write | mandatory |
| xPDUOutputRelayNormalState OBJECT-TYPE The normal operating position of the output relay. | 1.3.6.1.4.1.318.1.1.15.6.3.1.3 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| xPDUOutputRelayCurrentState OBJECT-TYPE This value indicates the current state of the output relay. | 1.3.6.1.4.1.318.1.1.15.6.3.1.4 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| xPDUMiscGroup OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.15.7 | |||
| xPDUEPOMode OBJECT-TYPE Indicates whether the EPO System is armed(1) or disarmed(2). | 1.3.6.1.4.1.318.1.1.15.7.1 | INTEGER {armed(1), disarmed(2), unknown(3)} | read-only | mandatory |
| xPDUTransformTempStatus OBJECT-TYPE Indicates if the PDU's isolation transformer is over temperature. | 1.3.6.1.4.1.318.1.1.15.7.2 | INTEGER {normal(1), overtemp(2), noTransformerPresent(3), unknown(4)} | read-only | mandatory |
| xPDUCoolingFanStatus OBJECT-TYPE Indicates if one or more of the PDU's cooling fans have failed. | 1.3.6.1.4.1.318.1.1.15.7.3 | INTEGER {normal(1), failed(2), noCoolingFansPresent(3), unknown(4)} | read-only | mandatory |
| battMan OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16 | |||
| battManIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.1 | |||
| battManIdentProductName OBJECT-TYPE The name of the battery manager. | 1.3.6.1.4.1.318.1.1.16.1.1 | DisplayString | read-write | mandatory |
| battManIdentHardwareRev OBJECT-TYPE The battery manager network interface hardware revision. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.16.1.2 | DisplayString | read-only | mandatory |
| battManIdentFirmwareRev OBJECT-TYPE The battery manager network interface firmware revision. This value is set at the factory and can change with firmware update. | 1.3.6.1.4.1.318.1.1.16.1.3 | DisplayString | read-only | mandatory |
| battManIdentDateOfManufacture OBJECT-TYPE The date the battery manager was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.16.1.4 | DisplayString | read-only | mandatory |
| battManIdentModelNumber OBJECT-TYPE The battery manager model number character string. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.16.1.5 | DisplayString | read-only | mandatory |
| battManIdentSerialNumber OBJECT-TYPE The battery manager serial number character string. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.16.1.6 | DisplayString | read-only | mandatory |
| battManSystemCalib OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.2 | |||
| battManOhmicValueCorrectionFactor OBJECT-TYPE The system ohmic value correction factor in percent. | 1.3.6.1.4.1.318.1.1.16.2.1 | INTEGER | read-write | mandatory |
| battManUnitCalib OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.3 | |||
| battManUnitCalibTableSize OBJECT-TYPE The number of entries in the battManUnitCalibTable. | 1.3.6.1.4.1.318.1.1.16.3.1 | INTEGER | read-only | mandatory |
| battManUnitCalibTable OBJECT-TYPE Allows for getting calibration information from each unit in the system. | 1.3.6.1.4.1.318.1.1.16.3.2 | not-accessible | mandatory | |
| battManUnitCalibEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.16.3.2.1 | not-accessible | mandatory | |
| battManUnitCalibIndex OBJECT-TYPE Index of unit calibration entries in the table. | 1.3.6.1.4.1.318.1.1.16.3.2.1.1 | INTEGER | read-only | mandatory |
| battManUnitSerialNumber OBJECT-TYPE The serial number of the unit. | 1.3.6.1.4.1.318.1.1.16.3.2.1.2 | DisplayString | read-only | mandatory |
| battManBatteryVoltageZeroCalib OBJECT-TYPE The unit battery voltage zero calibration in millivolts. | 1.3.6.1.4.1.318.1.1.16.3.2.1.3 | INTEGER | read-write | mandatory |
| battManBatteryVoltageSpanCalib OBJECT-TYPE The unit battery voltage span calibration in hundredths of percent. | 1.3.6.1.4.1.318.1.1.16.3.2.1.4 | INTEGER | read-write | mandatory |
| battManStringCalib OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.4 | |||
| battManStringCalibTableSize OBJECT-TYPE The number of entries in the battManStringCalibTable. | 1.3.6.1.4.1.318.1.1.16.4.1 | INTEGER | read-only | mandatory |
| battManStringCalibTable OBJECT-TYPE Allows for getting calibration information from each string in the system. | 1.3.6.1.4.1.318.1.1.16.4.2 | not-accessible | mandatory | |
| battManStringCalibEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.4.2.1 | not-accessible | mandatory | |
| battManStringCalibIndex OBJECT-TYPE Index of string calibration entries in the table. | 1.3.6.1.4.1.318.1.1.16.4.2.1.1 | INTEGER | read-only | mandatory |
| battManDCCurrentZeroCalib OBJECT-TYPE The string DC current zero calibration in tenths of amps. | 1.3.6.1.4.1.318.1.1.16.4.2.1.2 | INTEGER | read-write | mandatory |
| battManACCurrentZeroCalib OBJECT-TYPE The string AC current zero calibration in tenths of amps. | 1.3.6.1.4.1.318.1.1.16.4.2.1.3 | INTEGER | read-write | mandatory |
| battManProbeRange OBJECT-TYPE The string probe range in amps. | 1.3.6.1.4.1.318.1.1.16.4.2.1.4 | INTEGER {amps1000(1), amps500(2), amps100(3), amps200(4), amps2000(5)} | read-write | mandatory |
| battManBatteryCalib OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.5 | |||
| battManString1BatteryCalibTableSize OBJECT-TYPE The number of entries in the battManString1BatteryCalibTable. | 1.3.6.1.4.1.318.1.1.16.5.1 | INTEGER | read-only | mandatory |
| battManString1BatteryCalibTable OBJECT-TYPE Allows for getting calibration information from each battery in String 1. | 1.3.6.1.4.1.318.1.1.16.5.2 | not-accessible | mandatory | |
| battManString1BatteryCalibEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.5.2.1 | not-accessible | mandatory | |
| battManString1BatteryCalibIndex OBJECT-TYPE Index of battery calibration entries in the table. | 1.3.6.1.4.1.318.1.1.16.5.2.1.1 | INTEGER | read-only | mandatory |
| battManString1BatteryInterTierOhmicValue OBJECT-TYPE The battery inter-tier ohmic value in ohms. This corresponds to the ohmic value for the positive terminal of the battery. | 1.3.6.1.4.1.318.1.1.16.5.2.1.2 | INTEGER | read-write | mandatory |
| battManString2BatteryCalibTableSize OBJECT-TYPE The number of entries in the battManString2BatteryCalibTable. | 1.3.6.1.4.1.318.1.1.16.5.3 | INTEGER | read-only | mandatory |
| battManString2BatteryCalibTable OBJECT-TYPE Allows for getting calibration information from each battery in String 2. | 1.3.6.1.4.1.318.1.1.16.5.4 | not-accessible | mandatory | |
| battManString2BatteryCalibEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.5.4.1 | not-accessible | mandatory | |
| battManString2BatteryCalibIndex OBJECT-TYPE Index of battery calibration entries in the table. | 1.3.6.1.4.1.318.1.1.16.5.4.1.1 | INTEGER | read-only | mandatory |
| battManString2BatteryInterTierOhmicValue OBJECT-TYPE The battery inter-tier ohmic value in ohms. | 1.3.6.1.4.1.318.1.1.16.5.4.1.2 | INTEGER | read-write | mandatory |
| battManConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.6 | |||
| battManConfigApplication OBJECT-TYPE This OID has been deprecated. | 1.3.6.1.4.1.318.1.1.16.6.1 | INTEGER {silcon(1), other(2)} | read-write | deprecated |
| battManConfigBatteryChemistry OBJECT-TYPE The battery chemistry of the monitored batteries: LeadAcid(1) Lead Acid or Nickel-Cadmium(2) Nickel-Cadmium. | 1.3.6.1.4.1.318.1.1.16.6.2 | INTEGER {leadAcid(1), nickel-Cadmium(2)} | read-write | mandatory |
| battManConfigBatteryAHCapacity OBJECT-TYPE The amp hour capacity of the monitored batteries 5-4000 AH. | 1.3.6.1.4.1.318.1.1.16.6.3 | INTEGER | read-write | mandatory |
| battManConfigNumberofStrings OBJECT-TYPE The number of strings in the battery manager system. | 1.3.6.1.4.1.318.1.1.16.6.4 | INTEGER | read-write | mandatory |
| battManConfigBatteriesperString OBJECT-TYPE The number of batteries per string. | 1.3.6.1.4.1.318.1.1.16.6.5 | INTEGER | read-write | mandatory |
| battManConfigCellsperBattery OBJECT-TYPE The number of cells per battery (1, 2, 4 or 6 for lead-acid, 1 or 2 for NiCd. | 1.3.6.1.4.1.318.1.1.16.6.6 | INTEGER {oneCell(1), twoCells(2), fourCells(4), sixCells(6)} | read-write | mandatory |
| battManConfigMinCellVoltage OBJECT-TYPE The minimum battery cell voltage alarm limit in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.6.7 | INTEGER | read-write | mandatory |
| battManConfigMaxCellVoltage OBJECT-TYPE The maximum battery cell voltage alarm limit in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.6.8 | INTEGER | read-write | mandatory |
| battManConfigMaxPilotTempF OBJECT-TYPE The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.16.6.9 | INTEGER | read-write | mandatory |
| battManConfigMaxPilotTempC OBJECT-TYPE The maximum pilot battery temperature alarm limit in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.16.6.10 | INTEGER | read-write | mandatory |
| battManConfigMaxAmbientTempF OBJECT-TYPE The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.16.6.11 | INTEGER | read-write | mandatory |
| battManConfigMaxAmbientTempC OBJECT-TYPE The maximum ambient temperature alarm limit in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.16.6.12 | INTEGER | read-write | mandatory |
| battManConfigMinAmbientTempF OBJECT-TYPE The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.16.6.13 | INTEGER | read-write | mandatory |
| battManConfigMinAmbientTempC OBJECT-TYPE The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.16.6.14 | INTEGER | read-write | mandatory |
| battManConfigMaxRippleCurrent OBJECT-TYPE The maximum ripple current alarm limit for the monitored battery strings in percent of AH capacity. | 1.3.6.1.4.1.318.1.1.16.6.15 | INTEGER | read-write | mandatory |
| battManConfigMaxCurrentAcceptanceDeviation OBJECT-TYPE The maximum current acceptance deviation alarm limit in percent. | 1.3.6.1.4.1.318.1.1.16.6.16 | INTEGER | read-write | mandatory |
| battManConfigMonitorWireLength OBJECT-TYPE The monitor wire length: fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet. | 1.3.6.1.4.1.318.1.1.16.6.17 | INTEGER {fiftyFeetOrLess(1), moreThanFiftyFeet(2)} | read-write | mandatory |
| battManConfigDischargeVoltageAlarmLevel OBJECT-TYPE The discharge voltage alarm level in percent. | 1.3.6.1.4.1.318.1.1.16.6.18 | INTEGER | read-write | mandatory |
| battManConfigAutoAnnunciatorReset OBJECT-TYPE The annunciator output signal reset method: disabled(1) means the annunciator signal output will be reset when the reset button is pressed. enabled(2) means the annunciator will stop signaling when all alarm conditions clear. | 1.3.6.1.4.1.318.1.1.16.6.19 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| battManConfigSuspendCellVoltage OBJECT-TYPE This is used along with the number of cells per battery and the number of batteries per string to determine if a battery string has violated the low voltage limit. If so, the Battery Management System will enter suspend mode. Measured in millivolts DC | 1.3.6.1.4.1.318.1.1.16.6.20 | INTEGER | read-write | mandatory |
| battManConfigOhmicTestWaitTime OBJECT-TYPE The amount of time in seconds after a discharge event before data will be collected for the ohmic value calculation. | 1.3.6.1.4.1.318.1.1.16.6.21 | INTEGER | read-write | mandatory |
| battManConfigNumberOfBoosts OBJECT-TYPE The number of consecutive times the Battery Management System applies a charge to each battery during a boost cycle. Batteries with a Rated Battery AH Capacity less than or equal to 120 AH will always have a value of one for Number of Boosts. | 1.3.6.1.4.1.318.1.1.16.6.22 | INTEGER | read-write | mandatory |
| battManAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.7 | |||
| battManAlarmManagementController OBJECT-TYPE The Management Controller Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. | 1.3.6.1.4.1.318.1.1.16.7.1 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManAlarmBatteries OBJECT-TYPE The Batteries Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. | 1.3.6.1.4.1.318.1.1.16.7.2 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManAlarmCharger OBJECT-TYPE The Charger Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. | 1.3.6.1.4.1.318.1.1.16.7.3 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManAlarmEnvironment OBJECT-TYPE The Environment Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists. | 1.3.6.1.4.1.318.1.1.16.7.4 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.8 | |||
| battManSystemAmbientTempC OBJECT-TYPE The system ambient temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.16.8.1 | INTEGER | read-only | mandatory |
| battManSystemAmbientTempF OBJECT-TYPE The system ambient temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.16.8.2 | INTEGER | read-only | mandatory |
| battManSystemPilotTempC OBJECT-TYPE The system pilot temperature in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.16.8.3 | INTEGER | read-only | mandatory |
| battManSystemPilotTempF OBJECT-TYPE The system pilot temperature in tenths of degrees Fahrenheit. | 1.3.6.1.4.1.318.1.1.16.8.4 | INTEGER | read-only | mandatory |
| battManSystemAmbientHighTempAlarm OBJECT-TYPE When set to alarm(2), indicates that the system has a high temperature alarm. | 1.3.6.1.4.1.318.1.1.16.8.5 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemAmbientLowTempAlarm OBJECT-TYPE When set to alarm(2), indicates that the system has a low temperature alarm. | 1.3.6.1.4.1.318.1.1.16.8.6 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemPilotBatteryHighTempAlarm OBJECT-TYPE When set to alarm(2), indicates that the system has a pilot battery high temperature alarm. | 1.3.6.1.4.1.318.1.1.16.8.7 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemPilotProbeDisconnected OBJECT-TYPE When set to alarm(2), indicates that the system pilot probe is disconnected. | 1.3.6.1.4.1.318.1.1.16.8.8 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemAmbientProbeDisconnected OBJECT-TYPE When set to alarm(2), indicates that the system ambient probe is disconnected. | 1.3.6.1.4.1.318.1.1.16.8.9 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemConfigurationInvalid OBJECT-TYPE When set to alarm(2), indicates that the system is not configured correctly. | 1.3.6.1.4.1.318.1.1.16.8.10 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManSystemSuspendVoltage OBJECT-TYPE When set to alarm(2), indicates that the system has suspended voltage scans. | 1.3.6.1.4.1.318.1.1.16.8.11 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManStringStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.9 | |||
| battManStringTableSize OBJECT-TYPE The number of entries in the battManStringTable. | 1.3.6.1.4.1.318.1.1.16.9.1 | INTEGER | read-only | mandatory |
| battManStringTable OBJECT-TYPE Allows for getting information from each string in the system. | 1.3.6.1.4.1.318.1.1.16.9.2 | not-accessible | mandatory | |
| battManStringEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.9.2.1 | not-accessible | mandatory | |
| battManStringIndex OBJECT-TYPE Index of string entries in the table. | 1.3.6.1.4.1.318.1.1.16.9.2.1.1 | INTEGER | read-only | mandatory |
| battManStringCurrent OBJECT-TYPE The string current in tenths of amps. | 1.3.6.1.4.1.318.1.1.16.9.2.1.2 | INTEGER | read-only | mandatory |
| battManStringRippleCurrent OBJECT-TYPE The string ripple current in tenths of amps. | 1.3.6.1.4.1.318.1.1.16.9.2.1.3 | INTEGER | read-only | mandatory |
| battManStringChargerHighVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates that the string charger has a high voltage alarm. | 1.3.6.1.4.1.318.1.1.16.9.2.1.4 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManStringChargerLowVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates that the string charger has a low voltage alarm. | 1.3.6.1.4.1.318.1.1.16.9.2.1.5 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManStringCurrentProbeDisconnected OBJECT-TYPE When set to alarm(2), indicates that the string charger probe is disconnected. | 1.3.6.1.4.1.318.1.1.16.9.2.1.6 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManStringOnBattery OBJECT-TYPE When set to alarm(2), indicates that the string is in the on-battery state. | 1.3.6.1.4.1.318.1.1.16.9.2.1.7 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManStringHighRippleCurrent OBJECT-TYPE When set to alarm(2), indicates that the string has a high ripple current. | 1.3.6.1.4.1.318.1.1.16.9.2.1.8 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManStringVoltage OBJECT-TYPE The sum of the voltages for all of the batteries on a string in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.9.2.1.9 | INTEGER | read-only | mandatory |
| battManStringDischargeLess5Seconds OBJECT-TYPE The number of recorded discharges lasting less than 5 seconds. | 1.3.6.1.4.1.318.1.1.16.9.2.1.10 | INTEGER | read-only | mandatory |
| battManStringDischarge5to10Seconds OBJECT-TYPE The number of recorded discharges lasting between 5 and 10 seconds. | 1.3.6.1.4.1.318.1.1.16.9.2.1.11 | INTEGER | read-only | mandatory |
| battManStringDischarge10to60Seconds OBJECT-TYPE The number of recorded discharges lasting between 10 and 60 seconds. | 1.3.6.1.4.1.318.1.1.16.9.2.1.12 | INTEGER | read-only | mandatory |
| battManStringDischargeMore60Seconds OBJECT-TYPE The number of recorded discharges lasting more than 60 seconds (1 minute). | 1.3.6.1.4.1.318.1.1.16.9.2.1.13 | INTEGER | read-only | mandatory |
| battManBatteryStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.10 | |||
| battManString1BatteryTableSize OBJECT-TYPE The number of entries in the battManString1BatteryTable. | 1.3.6.1.4.1.318.1.1.16.10.1 | INTEGER | read-only | mandatory |
| battManString1BatteryTable OBJECT-TYPE Allows for getting information from each string in the system. | 1.3.6.1.4.1.318.1.1.16.10.2 | not-accessible | mandatory | |
| battManString1BatteryEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.10.2.1 | not-accessible | mandatory | |
| battManString1BatteryIndex OBJECT-TYPE Index of string entries in the table. | 1.3.6.1.4.1.318.1.1.16.10.2.1.1 | INTEGER | read-only | mandatory |
| battManString1BatteryVoltage OBJECT-TYPE The battery voltage in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.10.2.1.2 | INTEGER | read-only | mandatory |
| battManString1BatteryLowestVoltage OBJECT-TYPE The lowest battery discharge voltage during the last power event in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.10.2.1.3 | INTEGER | read-only | mandatory |
| battManString1BatteryCellShorted OBJECT-TYPE When set to alarm(2), indicates that a battery cell is shorted. | 1.3.6.1.4.1.318.1.1.16.10.2.1.4 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryOpenFuseOrConnection OBJECT-TYPE When set to alarm(2), indicates that a fuse or connection is open. | 1.3.6.1.4.1.318.1.1.16.10.2.1.5 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryLowCapacity OBJECT-TYPE When set to alarm(2), indicates a battery has low capacity. | 1.3.6.1.4.1.318.1.1.16.10.2.1.6 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryHighOhmicValue OBJECT-TYPE When set to alarm(2), indicates a battery has a high ohmic value. | 1.3.6.1.4.1.318.1.1.16.10.2.1.7 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryThermalRunaway OBJECT-TYPE When set to alarm(2), indicates a battery has a thermal runaway condition. | 1.3.6.1.4.1.318.1.1.16.10.2.1.8 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryDryout OBJECT-TYPE When set to alarm(2), indicates a battery has a dryout condition. | 1.3.6.1.4.1.318.1.1.16.10.2.1.9 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryUserHighVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the user level high voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.2.1.10 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryUserLowVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the user level low voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.2.1.11 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryChemHighVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.2.1.12 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryChemLowVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.2.1.13 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString1BatteryOpenCell OBJECT-TYPE When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal. | 1.3.6.1.4.1.318.1.1.16.10.2.1.14 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryTableSize OBJECT-TYPE The number of entries in the battManString2BatteryTable. | 1.3.6.1.4.1.318.1.1.16.10.3 | INTEGER | read-only | mandatory |
| battManString2BatteryTable OBJECT-TYPE Allows for getting information from each string in the system. | 1.3.6.1.4.1.318.1.1.16.10.4 | not-accessible | mandatory | |
| battManString2BatteryEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.10.4.1 | not-accessible | mandatory | |
| battManString2BatteryIndex OBJECT-TYPE Index of string entries in the table. | 1.3.6.1.4.1.318.1.1.16.10.4.1.1 | INTEGER | read-only | mandatory |
| battManString2BatteryVoltage OBJECT-TYPE The battery voltage in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.10.4.1.2 | INTEGER | read-only | mandatory |
| battManString2BatteryLowestVoltage OBJECT-TYPE The lowest battery discharge voltage during the last power event in millivolts DC. | 1.3.6.1.4.1.318.1.1.16.10.4.1.3 | INTEGER | read-only | mandatory |
| battManString2BatteryCellShorted OBJECT-TYPE When set to alarm(2), indicates that a battery cell is shorted. | 1.3.6.1.4.1.318.1.1.16.10.4.1.4 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryOpenFuseOrConnection OBJECT-TYPE When set to alarm(2), indicates that a fuse or connection is open. | 1.3.6.1.4.1.318.1.1.16.10.4.1.5 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryLowCapacity OBJECT-TYPE When set to alarm(2), indicates a battery has low capacity. | 1.3.6.1.4.1.318.1.1.16.10.4.1.6 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryHighOhmicValue OBJECT-TYPE When set to alarm(2), indicates a battery has a high ohmic value. | 1.3.6.1.4.1.318.1.1.16.10.4.1.7 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryThermalRunaway OBJECT-TYPE When set to alarm(2), indicates a battery has a thermal runaway condition. | 1.3.6.1.4.1.318.1.1.16.10.4.1.8 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryDryout OBJECT-TYPE When set to alarm(2), indicates a battery has a dryout condition. | 1.3.6.1.4.1.318.1.1.16.10.4.1.9 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryUserHighVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the user level high voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.4.1.10 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryUserLowVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the user level low voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.4.1.11 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryChemHighVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.4.1.12 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryChemLowVoltageAlarm OBJECT-TYPE When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit. | 1.3.6.1.4.1.318.1.1.16.10.4.1.13 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManString2BatteryOpenCell OBJECT-TYPE When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal. | 1.3.6.1.4.1.318.1.1.16.10.4.1.14 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManInputContactStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.11 | |||
| battManInputContactTableSize OBJECT-TYPE The number of entries in the battManInputContactTable. | 1.3.6.1.4.1.318.1.1.16.11.1 | INTEGER | read-only | mandatory |
| battManInputContactTable OBJECT-TYPE Allows for getting information from each contact in the system. | 1.3.6.1.4.1.318.1.1.16.11.2 | not-accessible | mandatory | |
| battManInputContactEntry OBJECT-TYPE The contact to get data from. | 1.3.6.1.4.1.318.1.1.16.11.2.1 | not-accessible | mandatory | |
| battManInputContactIndex OBJECT-TYPE Index of contact entries in the table. | 1.3.6.1.4.1.318.1.1.16.11.2.1.1 | INTEGER | read-only | mandatory |
| battManInputContactName OBJECT-TYPE The name of the input contact. | 1.3.6.1.4.1.318.1.1.16.11.2.1.2 | DisplayString | read-write | mandatory |
| battManInputContactAlarmState OBJECT-TYPE When set to alarm(2), indicates that the alarm condition is active for this contact. | 1.3.6.1.4.1.318.1.1.16.11.2.1.3 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManInputContactState OBJECT-TYPE When set to open(1), the input contact is in the open state. When set to closed(2), the input contact is in the closed state. | 1.3.6.1.4.1.318.1.1.16.11.2.1.4 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| battManInputContactNormalState OBJECT-TYPE When set to open(1), the input contact is normally open. When set to closed(2), the input contact is normally closed. | 1.3.6.1.4.1.318.1.1.16.11.2.1.5 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| battManInputContactAlarmDelay OBJECT-TYPE The input contact alarm delay time in seconds. | 1.3.6.1.4.1.318.1.1.16.11.2.1.6 | INTEGER | read-write | mandatory |
| battManControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.12 | |||
| battManRemoteAnnunciatorReset OBJECT-TYPE Setting this OID to reset(2) will reset the user interface annunciator. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.16.12.1 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| battManResetChargeCurrentDeviationBenchmark OBJECT-TYPE Setting this OID to reset(2) will reset the charge current deviation benchmark. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.16.12.2 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| battManResetLowestDischargeVoltages OBJECT-TYPE Setting this OID to reset(2) will reset the lowest discharge voltages. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.16.12.3 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| battManResetDischargeCounters OBJECT-TYPE Setting this OID to reset(2) will reset all discharge event counters. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.16.12.4 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| battManTestResults OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.13 | |||
| battManString1OhmicValueLastDischargeInfo OBJECT-TYPE Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded. | 1.3.6.1.4.1.318.1.1.16.13.1 | DisplayString | read-only | mandatory |
| battManString1OhmicValueTableSize OBJECT-TYPE The number of entries in the battManString1OhmicValueTable. | 1.3.6.1.4.1.318.1.1.16.13.2 | INTEGER | read-only | mandatory |
| battManString1OhmicValueTable OBJECT-TYPE Allows for getting ohmic value information from each battery in String 1. | 1.3.6.1.4.1.318.1.1.16.13.3 | not-accessible | mandatory | |
| battManString1OhmicValueEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.3.1 | not-accessible | mandatory | |
| battManString1OhmicValueIndex OBJECT-TYPE The battery number. | 1.3.6.1.4.1.318.1.1.16.13.3.1.1 | INTEGER | read-only | mandatory |
| battManString1OhmicValueData OBJECT-TYPE The battery inter-tier ohmic value in tenths of milli-Ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors. | 1.3.6.1.4.1.318.1.1.16.13.3.1.2 | INTEGER | read-only | mandatory |
| battManString1ResponseTestChangeTableSize OBJECT-TYPE The number of entries in the battManString1ResponseTestChangeTable. | 1.3.6.1.4.1.318.1.1.16.13.4 | INTEGER | read-only | mandatory |
| battManString1ResponseTestChangeTable OBJECT-TYPE Allows for getting response test change information from each battery in String 1. | 1.3.6.1.4.1.318.1.1.16.13.5 | not-accessible | mandatory | |
| battManString1ResponseTestChangeEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.5.1 | not-accessible | mandatory | |
| battManString1ResponseTestChangeIndex OBJECT-TYPE Index of the entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.5.1.1 | INTEGER | read-only | mandatory |
| battManString1ResponseTestChangeData OBJECT-TYPE The battery response test change in percent. | 1.3.6.1.4.1.318.1.1.16.13.5.1.2 | INTEGER | read-only | mandatory |
| battManString2OhmicValueLastDischargeInfo OBJECT-TYPE Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded. | 1.3.6.1.4.1.318.1.1.16.13.6 | DisplayString | read-only | mandatory |
| battManString2OhmicValueTableSize OBJECT-TYPE The number of entries in the battManString2OhmicValueTable. | 1.3.6.1.4.1.318.1.1.16.13.7 | INTEGER | read-only | mandatory |
| battManString2OhmicValueTable OBJECT-TYPE Allows for getting ohmic value information from each battery in String 2. | 1.3.6.1.4.1.318.1.1.16.13.8 | not-accessible | mandatory | |
| battManString2OhmicValueEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.8.1 | not-accessible | mandatory | |
| battManString2OhmicValueIndex OBJECT-TYPE Index of battery calibration entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.8.1.1 | INTEGER | read-only | mandatory |
| battManString2OhmicValueData OBJECT-TYPE The battery inter-tier ohmic value in ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors. | 1.3.6.1.4.1.318.1.1.16.13.8.1.2 | INTEGER | read-only | mandatory |
| battManString2ResponseTestChangeTableSize OBJECT-TYPE The number of entries in the battManString2ResponseTestChangeTable. | 1.3.6.1.4.1.318.1.1.16.13.9 | INTEGER | read-only | mandatory |
| battManString2ResponseTestChangeTable OBJECT-TYPE Allows for getting response test change information from each battery in String 2. | 1.3.6.1.4.1.318.1.1.16.13.10 | not-accessible | mandatory | |
| battManString2ResponseTestChangeEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.10.1 | not-accessible | mandatory | |
| battManString2ResponseTestChangeIndex OBJECT-TYPE Index of the entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.10.1.1 | INTEGER | read-only | mandatory |
| battManString2ResponseTestChangeData OBJECT-TYPE The battery response test change in percent. | 1.3.6.1.4.1.318.1.1.16.13.10.1.2 | INTEGER | read-only | mandatory |
| battManString1ResponseTestCurrentTableSize OBJECT-TYPE The number of entries in the battManString1ResponseTestCurrentTable. | 1.3.6.1.4.1.318.1.1.16.13.11 | INTEGER | read-only | mandatory |
| battManString1ResponseTestCurrentTable OBJECT-TYPE Allows for getting response test current information from each battery in String 1. | 1.3.6.1.4.1.318.1.1.16.13.12 | not-accessible | mandatory | |
| battManString1ResponseTestCurrentEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.12.1 | not-accessible | mandatory | |
| battManString1ResponseTestCurrentIndex OBJECT-TYPE Index of the entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.12.1.1 | INTEGER | read-only | mandatory |
| battManString1ResponseTestCurrentData OBJECT-TYPE The battery response test current in milliamps. | 1.3.6.1.4.1.318.1.1.16.13.12.1.2 | INTEGER | read-only | mandatory |
| battManString2ResponseTestCurrentTableSize OBJECT-TYPE The number of entries in the battManString2ResponseTestCurrentTable. | 1.3.6.1.4.1.318.1.1.16.13.13 | INTEGER | read-only | mandatory |
| battManString2ResponseTestCurrentTable OBJECT-TYPE Allows for getting response test current information from each battery in String 2. | 1.3.6.1.4.1.318.1.1.16.13.14 | not-accessible | mandatory | |
| battManString2ResponseTestCurrentEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.14.1 | not-accessible | mandatory | |
| battManString2ResponseTestCurrentIndex OBJECT-TYPE Index of the entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.14.1.1 | INTEGER | read-only | mandatory |
| battManString2ResponseTestCurrentData OBJECT-TYPE The battery response test current in milliamps. | 1.3.6.1.4.1.318.1.1.16.13.14.1.2 | INTEGER | read-only | mandatory |
| battManString1ResponseTestCurrentBenchmarkTableSize OBJECT-TYPE The number of entries in the battManString1ResponseTestCurrentBenchmarkTable. | 1.3.6.1.4.1.318.1.1.16.13.15 | INTEGER | read-only | mandatory |
| battManString1ResponseTestCurrentBenchmarkTable OBJECT-TYPE Allows for getting response test current benchmark information from each battery in String 1. | 1.3.6.1.4.1.318.1.1.16.13.16 | not-accessible | mandatory | |
| battManString1ResponseTestCurrentBenchmarkEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.16.1 | not-accessible | mandatory | |
| battManString1ResponseTestCurrentBenchmarkIndex OBJECT-TYPE Index of the entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.16.1.1 | INTEGER | read-only | mandatory |
| battManString1ResponseTestCurrentBenchmarkData OBJECT-TYPE The battery response test current benchmark in milliamps. | 1.3.6.1.4.1.318.1.1.16.13.16.1.2 | INTEGER | read-only | mandatory |
| battManString2ResponseTestCurrentBenchmarkTableSize OBJECT-TYPE The number of entries in the battManString2ResponseTestCurrentBenchmarkTable. | 1.3.6.1.4.1.318.1.1.16.13.17 | INTEGER | read-only | mandatory |
| battManString2ResponseTestCurrentBenchmarkTable OBJECT-TYPE Allows for getting response test current benchmark information from each battery in String 2. | 1.3.6.1.4.1.318.1.1.16.13.18 | not-accessible | mandatory | |
| battManString2ResponseTestCurrentBenchmarkEntry OBJECT-TYPE The string to get data from. | 1.3.6.1.4.1.318.1.1.16.13.18.1 | not-accessible | mandatory | |
| battManString2ResponseTestCurrentBenchmarkIndex OBJECT-TYPE Index of the entries in the table. | 1.3.6.1.4.1.318.1.1.16.13.18.1.1 | INTEGER | read-only | mandatory |
| battManString2ResponseTestCurrentBenchmarkData OBJECT-TYPE The battery response test current benchmark in milliamps. | 1.3.6.1.4.1.318.1.1.16.13.18.1.2 | INTEGER | read-only | mandatory |
| battManUnitStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.16.14 | |||
| battManUnitStatusTableSize OBJECT-TYPE The number of entries in the battManUnitStatusTable. | 1.3.6.1.4.1.318.1.1.16.14.1 | INTEGER | read-only | mandatory |
| battManUnitStatusTable OBJECT-TYPE Allows for getting status information from each unit in the system. | 1.3.6.1.4.1.318.1.1.16.14.2 | not-accessible | mandatory | |
| battManUnitStatusEntry OBJECT-TYPE The unit to get data from. | 1.3.6.1.4.1.318.1.1.16.14.2.1 | not-accessible | mandatory | |
| battManUnitStatusIndex OBJECT-TYPE Index of unit status entries in the table. | 1.3.6.1.4.1.318.1.1.16.14.2.1.1 | INTEGER | read-only | mandatory |
| battManUnitStatusSerialNumber OBJECT-TYPE The battery manager unit serial number character string. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.16.14.2.1.2 | DisplayString | read-only | mandatory |
| battManUnitHardwareRev OBJECT-TYPE The battery manager unit hardware revision. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.16.14.2.1.3 | INTEGER | read-only | mandatory |
| battManUnitFirmwareRev OBJECT-TYPE The battery manager unit firmware revision. This value is set at the factory and can change with firmware update. | 1.3.6.1.4.1.318.1.1.16.14.2.1.4 | INTEGER | read-only | mandatory |
| battManUnitCommLoss OBJECT-TYPE When set to alarm(2), indicates the system has lost communication with the unit. | 1.3.6.1.4.1.318.1.1.16.14.2.1.5 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| battManUnitRelayStuck OBJECT-TYPE When set to alarm(2), indicates the unit monitor relay is stuck. | 1.3.6.1.4.1.318.1.1.16.14.2.1.6 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| xATS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17 | |||
| xATSIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.1 | |||
| xATSIdentProductName OBJECT-TYPE The name of the transfer switch unit. | 1.3.6.1.4.1.318.1.1.17.1.1 | DisplayString | read-write | mandatory |
| xATSIdentHardwareRev OBJECT-TYPE The hardware revision of the transfer switch. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.17.1.2 | DisplayString | read-only | mandatory |
| xATSIdentFirmwareAppRev OBJECT-TYPE An ID string identifying the application firmware revision of the transfer switch. | 1.3.6.1.4.1.318.1.1.17.1.3 | DisplayString | read-only | mandatory |
| xATSIdentFirmwareAppOSRev OBJECT-TYPE An ID string identifying the application operating system firmware revision of the transfer switch. | 1.3.6.1.4.1.318.1.1.17.1.4 | DisplayString | read-only | mandatory |
| xATSIdentFirmwareControllerRev OBJECT-TYPE An ID string identifying the transfer switch controller firmware revision. | 1.3.6.1.4.1.318.1.1.17.1.5 | DisplayString | read-only | mandatory |
| xATSIdentDateOfManufacture OBJECT-TYPE The date when the transfer switch was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.17.1.6 | DisplayString | read-only | mandatory |
| xATSIdentModelNumber OBJECT-TYPE A character string identifying the model number of the transfer switch. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.17.1.7 | DisplayString | read-only | mandatory |
| xATSIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the transfer switch. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.17.1.8 | DisplayString | read-only | mandatory |
| xATSDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.2 | |||
| xATSDeviceServiceType OBJECT-TYPE The type of utility input to the transfer switch. Either 3 wires (delta), or 4 wires (wye). | 1.3.6.1.4.1.318.1.1.17.2.1 | INTEGER {threeWire(1), fourWire(2)} | read-only | mandatory |
| xATSDeviceNominalVoltage OBJECT-TYPE The nominal line-to-neutral system voltage. Measured in Volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.2.2 | INTEGER | read-only | mandatory |
| xATSDeviceNominalFrequency OBJECT-TYPE The nominal system frequency. Measured in tenths of Hertz. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.2.3 | INTEGER | read-only | mandatory |
| xATSDeviceTransferSwitchRating OBJECT-TYPE The rating of the transfer switch. Measured in Amps. | 1.3.6.1.4.1.318.1.1.17.2.4 | INTEGER | read-only | mandatory |
| xATSDeviceDCBackUpPresent OBJECT-TYPE Indicates if a DC backup is present or not. | 1.3.6.1.4.1.318.1.1.17.2.5 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| xATSSwitch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.3 | |||
| xATSSwitchStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.3.1 | |||
| xATSSwitchStatusSelectedSource OBJECT-TYPE The source which is currently selected, i.e. supplying power to the load. | 1.3.6.1.4.1.318.1.1.17.3.1.1 | INTEGER {none(1), source1(2), source2(3), fault(4), unknown(5)} | read-only | mandatory |
| xATSSwitchStatusOperationalMode OBJECT-TYPE The current operating mode of the transfer switch. When the ATS is in automatic mode, generator starting and ATS transferring is all done automatically as needed based on the state of source 1. Automatic operation is halted when the ATS is in either of the notInAuto modes. A mode of notInAuto indicates that the automatic operation switch is in the disabled position, as indicated by the xATSSwitchStatusAutomaticOperationSwitch OID. The notInAutoAbnormal condition indicates that an abnormal condition has caused the transfer switch to halt automatic operation. In this case, traps can indicate the exact problem. In the case of notInAutoAbnormal, refer to the operation manual for details on how debug the condition and restore automatic operation. | 1.3.6.1.4.1.318.1.1.17.3.1.2 | INTEGER {automatic(1), notInAutoAbnormal(2), notInAuto(3), unknown(4)} | read-only | mandatory |
| xATSSwitchStatusAutomaticOperationSwitch OBJECT-TYPE The position of the automatic operation switch on the front of the transfer switch. | 1.3.6.1.4.1.318.1.1.17.3.1.3 | INTEGER {disabled(1), enabled(2), unknown(3)} | read-only | mandatory |
| xATSSwitchStatusEngineStartSignal OBJECT-TYPE The position of the Start/Stop contact which signals the generator engine to start/run. When the ATS is in automatic mode, generator starting/stopping is under ATS control. | 1.3.6.1.4.1.318.1.1.17.3.1.4 | INTEGER {run(1), stop(2), unknown(3)} | read-only | mandatory |
| xATSSwitchSettings OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.3.2 | |||
| xATSSwitchSettingsLowVoltageTransferPoint OBJECT-TYPE The lowest acceptable voltage condition at source 1. When any phase of source 1 is lower than this voltage, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.3.2.1 | INTEGER | read-write | mandatory |
| xATSSwitchSettingsHighVoltageTransferPoint OBJECT-TYPE The highest acceptable voltage condition at source 1. When any phase of source 1 is greater than this voltage, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.3.2.2 | INTEGER | read-write | mandatory |
| xATSSwitchSettingsMaxFrequencyDeviation OBJECT-TYPE The maximum acceptable frequency deviation condition from nominal at source 1. When source 1 frequency is outside the specified range, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in tenths of Hertz above or below nominal. A value of zero indicates that frequency is ignored when determining source quality. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.3.2.3 | INTEGER | read-write | mandatory |
| xATSSwitchSettingsMinPhaseBalance OBJECT-TYPE The minimum required phase balance at source 1. When the percentage difference between the minimum and maximum phase voltage measurements at source 1 is greater than this value, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified as a percentage. A value of zero indicates that phase balance is ignored when determining source quality. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.3.2.4 | INTEGER | read-write | mandatory |
| xATSSwitchSettingsNominalRotation OBJECT-TYPE The nominal phase rotation (or phase sequence) required by the load. For certain types of equipment, such as rotating machinery, phase rotation is critical for proper operation as it determines the direction which motors will rotate (clockwise or counterclockwise). Source quality will be seen as bad if the rotation measured at that ATS input does not match this setting. If this setting is set to any, phase rotation is ignored. | 1.3.6.1.4.1.318.1.1.17.3.2.5 | INTEGER {abc(1), cba(2), any(3), unknown(4)} | read-write | mandatory |
| xATSSwitchSettingsAllowClosedTransfer OBJECT-TYPE This setting enables seamless (closed) transfers between sources. When possible, both source 1 and source 2 are closed to the output for a brief time. If closed transfer is not possible within the amount of time specified by the xATSSwitchSettingsMaxSyncTime OID, an open transfer will be executed. | 1.3.6.1.4.1.318.1.1.17.3.2.6 | INTEGER {yes(1), no(2), unknown(3)} | read-write | mandatory |
| xATSSwitchSettingsMaxSyncTime OBJECT-TYPE When attempting/seeking to perform a closed transfer, this setting defines the maximum time allowed before the transfer switch will give up and perform an open transfer. Specified in seconds. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.3.2.7 | INTEGER | read-write | mandatory |
| xATSSwitchSettingsNeutralTransferTime OBJECT-TYPE This setting defines how long both source 1 and source 2 will be disconnected from the output, during an open transfer. Specified in seconds. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.3.2.8 | INTEGER | read-write | mandatory |
| xATSSwitchSettingsClearLatchedAlarms OBJECT-TYPE Clears any latched alarm conditions. | 1.3.6.1.4.1.318.1.1.17.3.2.9 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| xATSSwitchSettingsSetToFactoryDefaults OBJECT-TYPE Sets all transfer switch settings to factory default values. | 1.3.6.1.4.1.318.1.1.17.3.2.10 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| xATSSwitchTimers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.3.3 | |||
| xATSSwitchTimersTableSize OBJECT-TYPE The number of transfer switch timer entries. | 1.3.6.1.4.1.318.1.1.17.3.3.1 | INTEGER | read-only | mandatory |
| xATSSwitchTimersTable OBJECT-TYPE A list of timers supported by ATS. The number of entries is contained in the xATSSwitchTimersTableSize OID. | 1.3.6.1.4.1.318.1.1.17.3.3.2 | not-accessible | mandatory | |
| xATSSwitchTimersEntry OBJECT-TYPE An entry containing information about an individual ATS timer. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1 | not-accessible | mandatory | |
| xATSSwitchTimersIndex OBJECT-TYPE Index of timer entries in the table. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1.1 | INTEGER | read-only | mandatory |
| xATSSwitchTimersName OBJECT-TYPE Name of the individual timer.Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1.2 | DisplayString | read-only | mandatory |
| xATSSwitchTimersAbort OBJECT-TYPE This aborts the individual timer. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| xATSSwitchTimersStatus OBJECT-TYPE The status of the individual timer. Designates whether this timer entry is currently running or inactive. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1.4 | INTEGER {inactive(1), active(2)} | read-only | mandatory |
| xATSSwitchTimersRemainingTime OBJECT-TYPE The time remaining for this timer entry. Specified in seconds. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1.5 | INTEGER | read-only | mandatory |
| xATSSwitchTimersDelaySetting OBJECT-TYPE The delay settings associated with this timer entry. When this timer entry is active, the timer value must exceed this setting before the ATS behavior associated with this timer is executed. Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers. | 1.3.6.1.4.1.318.1.1.17.3.3.2.1.6 | INTEGER | read-write | mandatory |
| xATSSwitchBlockMap OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.3.4 | |||
| xATSSwitchBlockMapTableSize OBJECT-TYPE The number of blocking map entries, or how many ATS actions can be blocked. | 1.3.6.1.4.1.318.1.1.17.3.4.1 | INTEGER | read-only | mandatory |
| xATSSwitchBlockMapTable OBJECT-TYPE A list of blocking maps supported by the ATS. The number of entries is contained in the xATSSwitchBlockMapTableSize OID. | 1.3.6.1.4.1.318.1.1.17.3.4.2 | not-accessible | mandatory | |
| xATSSwitchBlockMapEntry OBJECT-TYPE An entry containing information about a specific ATS blocking map. | 1.3.6.1.4.1.318.1.1.17.3.4.2.1 | not-accessible | mandatory | |
| xATSSwitchBlockMapIndex OBJECT-TYPE Index of blocking map entries in the table. | 1.3.6.1.4.1.318.1.1.17.3.4.2.1.1 | INTEGER | read-only | mandatory |
| xATSSwitchBlockMapName OBJECT-TYPE A string describing the ATS action to be blocked. | 1.3.6.1.4.1.318.1.1.17.3.4.2.1.2 | DisplayString | read-only | mandatory |
| xATSSwitchBlockMapStatus OBJECT-TYPE Represents the status of this blocking map entry, in bit-mapped format. A non-zero value indicates that this entry's ATS action is currently being blocked. The bit(s) set indicate which input(s) are causing the blocking (bit0, bit1, etc). bit 0 - Contact 1 bit 1 - Contact 2 bit 2 - Contact 3 bit 3 - Contact 4. | 1.3.6.1.4.1.318.1.1.17.3.4.2.1.3 | INTEGER | read-only | mandatory |
| xATSSwitchBlockMapSetting OBJECT-TYPE This setting designates the inputs that block the ATS action The mapping is specified as a bit-field, where each bit set indicates the input that blocks the ATS action associated with the entry. bit 0 - Contact 1 bit 1 - Contact 2 bit 2 - Contact 3 bit 3 - Contact 4. | 1.3.6.1.4.1.318.1.1.17.3.4.2.1.4 | INTEGER | read-write | mandatory |
| xATSSwitchStatistics OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.3.5 | |||
| xATSSwitchStatisticsTableSize OBJECT-TYPE The number of transfer switch statistics entries. | 1.3.6.1.4.1.318.1.1.17.3.5.1 | INTEGER | read-only | mandatory |
| xATSSwitchStatisticsTable OBJECT-TYPE A list of statistics supported by ATS. The number of entries is contained in the xATSSwitchStatisticsTableSize OID. | 1.3.6.1.4.1.318.1.1.17.3.5.2 | not-accessible | mandatory | |
| xATSSwitchStatisticsEntry OBJECT-TYPE An entry containing information about an individual ATS statistic. | 1.3.6.1.4.1.318.1.1.17.3.5.2.1 | not-accessible | mandatory | |
| xATSSwitchStatisticsIndex OBJECT-TYPE Index of ATS statistics entries in the table. | 1.3.6.1.4.1.318.1.1.17.3.5.2.1.1 | INTEGER | read-only | mandatory |
| xATSSwitchStatisticsName OBJECT-TYPE This is the name of the ATS statistic associated with this entry. | 1.3.6.1.4.1.318.1.1.17.3.5.2.1.2 | DisplayString | read-only | mandatory |
| xATSSwitchStatisticsValue OBJECT-TYPE This is the value of the ATS statistic associated with this entry. | 1.3.6.1.4.1.318.1.1.17.3.5.2.1.3 | DisplayString | read-only | mandatory |
| xATSSwitchStatisticsReset OBJECT-TYPE This will reset the individual ATS statistic associated with this entry. | 1.3.6.1.4.1.318.1.1.17.3.5.2.1.4 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| xATSACMonitoringPoint OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.4 | |||
| xATSSource1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.4.1 | |||
| xATSSource1Name OBJECT-TYPE String used to identify source 1. | 1.3.6.1.4.1.318.1.1.17.4.1.1 | DisplayString | read-write | mandatory |
| xATSSource1Position OBJECT-TYPE The current position of the switch at source 1. | 1.3.6.1.4.1.318.1.1.17.4.1.2 | INTEGER {open(1), closed(2), tripped(3), unknown(4)} | read-only | mandatory |
| xATSSource1Frequency OBJECT-TYPE The frequency at source 1 in tenths of Hertz. -1 if unavailable. | 1.3.6.1.4.1.318.1.1.17.4.1.3 | INTEGER | read-only | mandatory |
| xATSSource1Quality OBJECT-TYPE The current line quality of source 1. | 1.3.6.1.4.1.318.1.1.17.4.1.4 | INTEGER {sourceGood(1), lowVoltage(2), highVoltage(3), phaseImbalance(4), freqOutOfRange(5), badRotation(6), unknown(7)} | read-only | mandatory |
| xATSSource1Rotation OBJECT-TYPE The phase rotation measured at the source 1 input of the ATS. The sequence is a reference to the order in which the three phases pass the zero-crossing boundary in time. | 1.3.6.1.4.1.318.1.1.17.4.1.5 | INTEGER {abc(1), cba(2), unknown(3)} | read-only | mandatory |
| xATSSource1TableSize OBJECT-TYPE The number of input voltage entries at the source 1 input of the ATS. | 1.3.6.1.4.1.318.1.1.17.4.1.6 | INTEGER | read-only | mandatory |
| xATSSource1PhaseTable OBJECT-TYPE A list of voltage table entries for source 1. The number of entries are the phase entries. The number of entries is contained in the xATSSource1TableSize OID. | 1.3.6.1.4.1.318.1.1.17.4.1.7 | not-accessible | mandatory | |
| xATSSource1PhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input voltage phase at the source 1 input of the ATS. | 1.3.6.1.4.1.318.1.1.17.4.1.7.1 | not-accessible | mandatory | |
| xATSSource1Index OBJECT-TYPE Description of each phase utilized at source 1. | 1.3.6.1.4.1.318.1.1.17.4.1.7.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xATSSource1VoltageLtoL OBJECT-TYPE Source 1 line-to-line input voltage. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.17.4.1.7.1.2 | INTEGER | read-only | mandatory |
| xATSSource1VoltageLtoN OBJECT-TYPE Source 1 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type. | 1.3.6.1.4.1.318.1.1.17.4.1.7.1.3 | INTEGER | read-only | mandatory |
| xATSSource2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.4.2 | |||
| xATSSource2Name OBJECT-TYPE String used to identify source 2. | 1.3.6.1.4.1.318.1.1.17.4.2.1 | DisplayString | read-write | mandatory |
| xATSSource2Position OBJECT-TYPE The current position of the switch at source 2. | 1.3.6.1.4.1.318.1.1.17.4.2.2 | INTEGER {open(1), closed(2), tripped(3), unknown(4)} | read-only | mandatory |
| xATSSource2Frequency OBJECT-TYPE The frequency at source 2 in tenths of Hertz. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.4.2.3 | INTEGER | read-only | mandatory |
| xATSSource2Quality OBJECT-TYPE The current line quality of source 2. | 1.3.6.1.4.1.318.1.1.17.4.2.4 | INTEGER {sourceGood(1), lowVoltage(2), highVoltage(3), phaseImbalance(4), freqOutOfRange(5), badRotation(6), unknown(7)} | read-only | mandatory |
| xATSSource2Rotation OBJECT-TYPE The phase rotation measured at the source 2 input of the ATS. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.4.2.5 | INTEGER {abc(1), cba(2), unknown(3)} | read-only | mandatory |
| xATSSource2TableSize OBJECT-TYPE The number of input voltage entries at the source 2 input of the ATS. | 1.3.6.1.4.1.318.1.1.17.4.2.6 | INTEGER | read-only | mandatory |
| xATSSource2PhaseTable OBJECT-TYPE A list of voltage table entries for the source 2. The number of entries are the phase entries. The number of entries is contained in the xATSSource2TableSize OID. | 1.3.6.1.4.1.318.1.1.17.4.2.7 | not-accessible | mandatory | |
| xATSSource2PhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input voltage phase at the source 2 input of the ATS. | 1.3.6.1.4.1.318.1.1.17.4.2.7.1 | not-accessible | mandatory | |
| xATSSource2Index OBJECT-TYPE Description of each phase utilized at the source 2. | 1.3.6.1.4.1.318.1.1.17.4.2.7.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xATSSource2VoltageLtoL OBJECT-TYPE Source 2 line-to-line input voltage. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.17.4.2.7.1.2 | INTEGER | read-only | mandatory |
| xATSSource2VoltageLtoN OBJECT-TYPE Source 2 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type. | 1.3.6.1.4.1.318.1.1.17.4.2.7.1.3 | INTEGER | read-only | mandatory |
| xATSSystemOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.4.3 | |||
| xATSSystemOutputFrequency OBJECT-TYPE The system output frequency in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.17.4.3.1 | INTEGER | read-only | mandatory |
| xATSSystemOutputTotalPower OBJECT-TYPE Shows the total system output power in tenths of kW. | 1.3.6.1.4.1.318.1.1.17.4.3.2 | INTEGER | read-only | mandatory |
| xATSSystemOutputTotalApparentPower OBJECT-TYPE Shows the total system output power in tenths of kVA. | 1.3.6.1.4.1.318.1.1.17.4.3.3 | INTEGER | read-only | mandatory |
| xATSSystemOutputTotalPowerFactor OBJECT-TYPE Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00) Specified in hundredths. | 1.3.6.1.4.1.318.1.1.17.4.3.4 | INTEGER | read-only | mandatory |
| xATSSystemOutputFrequencyTolerance OBJECT-TYPE Shows the panel output frequency tolerance in +/- Hertz. | 1.3.6.1.4.1.318.1.1.17.4.3.5 | INTEGER {freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10)} | read-write | mandatory |
| xATSSystemOutputOverVoltThreshold OBJECT-TYPE Threshold above which an output over voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.17.4.3.6 | INTEGER | read-write | mandatory |
| xATSSystemOutputUnderVoltThreshold OBJECT-TYPE Threshold below which an output under voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.17.4.3.7 | INTEGER | read-write | mandatory |
| xATSSystemOutputOverCurrentThreshold OBJECT-TYPE Threshold above which an over current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.17.4.3.8 | INTEGER (0..100) | read-write | mandatory |
| xATSSystemOutputUnderCurrentThreshold OBJECT-TYPE Threshold below which an under current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.17.4.3.9 | INTEGER (0..100) | read-write | mandatory |
| xATSSystemOutputAlarmDelayThreshold OBJECT-TYPE Delay the generation of an output alarm. Specified in seconds. | 1.3.6.1.4.1.318.1.1.17.4.3.10 | INTEGER | read-write | mandatory |
| xATSSystemOutputTableSize OBJECT-TYPE The number of system output phase entries. | 1.3.6.1.4.1.318.1.1.17.4.3.11 | INTEGER | read-only | mandatory |
| xATSSystemOutputPhaseTable OBJECT-TYPE A list of system output table entries. The number of entries is contained in the xATSSystemOutputTableSize OID. | 1.3.6.1.4.1.318.1.1.17.4.3.12 | not-accessible | mandatory | |
| xATSSystemOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular system output phase. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1 | not-accessible | mandatory | |
| xATSSystemOutputPhaseIndex OBJECT-TYPE Description of each system output phase utilized in this device. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xATSSystemOutputVoltageLtoL OBJECT-TYPE Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.2 | INTEGER | read-only | mandatory |
| xATSSystemOutputVoltageLtoN OBJECT-TYPE Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts. -1 for a 3-wire service type or if not available. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.3 | INTEGER | read-only | mandatory |
| xATSSystemOutputPhaseCurrent OBJECT-TYPE System load current per phase. Measured in Amps. -1 if not available. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.4 | INTEGER | read-only | mandatory |
| xATSSystemOutputPower OBJECT-TYPE System output power per phase. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.5 | INTEGER | read-only | mandatory |
| xATSSystemOutputApparentPower OBJECT-TYPE system output power per phase. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.6 | INTEGER | read-only | mandatory |
| xATSSystemOutputPowerFactor OBJECT-TYPE indicates the power factor of the system output per phase. A value of 100 representing a unity power factor (1.00). Measured in hundredths. | 1.3.6.1.4.1.318.1.1.17.4.3.12.1.7 | INTEGER | read-only | mandatory |
| xATSTesting OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.5 | |||
| xATSTestingStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.5.1 | |||
| xATSTestingStatusSelectTestProcess OBJECT-TYPE Type of tests that can be selected when no test has been scheduled. engineStartTest and systemLoadTest may be selected when no tests are running. Tests that are selected may be canceled manually. | 1.3.6.1.4.1.318.1.1.17.5.1.1 | INTEGER {engineStartTest(1), systemLoadTest(2), generatorHoldTest(3), cancelTest(4)} | read-write | mandatory |
| xATSTestingStatusTestStatus OBJECT-TYPE The present system test status/state. | 1.3.6.1.4.1.318.1.1.17.5.1.2 | INTEGER {noTestInProcess(1), testPending(2), startingEngine(3), engineWarmingUp(4), awaitingTransferToS2(5), testingWithLoad(6), awaitingRetransferToS1(7), testingWithoutLoad(8), stoppingEngine(9), holdingOnGenerator(10)} | read-only | mandatory |
| xATSTestingStatusProfileWarmupTime OBJECT-TYPE The amount of time that the generator will warm up during a test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value engineWarmingUp. Specified in seconds. | 1.3.6.1.4.1.318.1.1.17.5.1.3 | INTEGER | read-write | mandatory |
| xATSTestingStatusProfileLoadedTime OBJECT-TYPE The amount of time that ATS will apply the system load to the generator during a system load test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value testingWithLoad. Specified in minutes. | 1.3.6.1.4.1.318.1.1.17.5.1.4 | INTEGER | read-write | mandatory |
| xATSTestingStatusProfileUnloadedTime OBJECT-TYPE The amount of time that the generator will run following the warm up portion of a start test, or the loaded portion of a load test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value testingWithoutLoad. Specified in seconds. | 1.3.6.1.4.1.318.1.1.17.5.1.5 | INTEGER | read-write | mandatory |
| xATSTestingResults OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.5.2 | |||
| xATSTestingResultsLastDateOfTest OBJECT-TYPE Date of the last test that was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the dd/mm/yyyy format, or 'none' if not available. | 1.3.6.1.4.1.318.1.1.17.5.2.1 | DisplayString | read-only | mandatory |
| xATSTestingResultsLastResult OBJECT-TYPE The result of the last ATS/generator system test. | 1.3.6.1.4.1.318.1.1.17.5.2.2 | INTEGER {noResultsAvailable(1), startTestPassed(2), loadTestPassed(3), startSignalFailure(4), failedGenNotInAuto(5), failedGenEmerStop(6), failedGenShutdown(7), failedGenDidNotStart(8), failedS2NeverGood(9), genFailedDuringWarmup(10), failureOnXferToS1(11), genFailedLoaded(12), failureOnRexferToS2(13), failedOnCooldown(14), genFailedToStop(15), failedAtsInternalFault(16), failedAtsNotInAuto(17), canceledManualTest(18), canceledScheduledTest(19)} | read-only | mandatory |
| xATSTestingResultsTestLastTestTime OBJECT-TYPE Time of day at which the last test was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the hh:mm:ss format, or 'none' if not available. | 1.3.6.1.4.1.318.1.1.17.5.2.3 | DisplayString | read-only | mandatory |
| xATSTestingResultsLastCrankDuration OBJECT-TYPE The time spent cranking the generator before it started during the last test. Specified in seconds, or -1 if not available. | 1.3.6.1.4.1.318.1.1.17.5.2.4 | INTEGER | read-only | mandatory |
| xATSTestingResultsLastWarmupDuration OBJECT-TYPE The time spent in the engineWarmingUp state during the last system test. Specified in seconds, or -1 if not available. | 1.3.6.1.4.1.318.1.1.17.5.2.5 | INTEGER | read-only | mandatory |
| xATSTestingResultsLastLoadedDuration OBJECT-TYPE The time spent in the testingWithLoad state during the last system test. Specified in seconds, or -1 if not available. | 1.3.6.1.4.1.318.1.1.17.5.2.6 | INTEGER | read-only | mandatory |
| xATSTestingResultsLastUnloadedDuration OBJECT-TYPE The time spent in the testingWithoutLoad state during the last system test. Specified in seconds, or -1 if not available. | 1.3.6.1.4.1.318.1.1.17.5.2.7 | INTEGER | read-only | mandatory |
| xATSTestingSchedule OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.5.3 | |||
| xATSTestingScheduleFrequency OBJECT-TYPE The frequency of running scheduled tests. | 1.3.6.1.4.1.318.1.1.17.5.3.1 | INTEGER {never(1), daily(2), weekly(3), monthly(4)} | read-write | mandatory |
| xATSTestingScheduleTestDay OBJECT-TYPE The desired day for the scheduled test. This object applies only when the xATSTestingScheduleFrequency OID is set to weekly or monthly. For weekly test frequency, the string is the day the test will be run. For monthly test frequency, the string indicates the day, and the instance within the month. For example, for monthly frequency: 2nd Sunday, 3rd Monday, 4th Tuesday, for weekly frequency: Sunday, Monday, Tuesday. | 1.3.6.1.4.1.318.1.1.17.5.3.2 | DisplayString | read-write | mandatory |
| xATSTestingScheduleTestTime OBJECT-TYPE The time of day that the scheduled test will occur. Specified in the format hh:mm. | 1.3.6.1.4.1.318.1.1.17.5.3.3 | DisplayString | read-write | mandatory |
| xATSTestingScheduleTestWithLoadInterval OBJECT-TYPE This setting specifies which system tests should include applying the load to the generator. The applyLoadMonthlyDetailed entry in the list will apply load once, for each month represented in the xATSTestingScheduleTestWithLoadSelectMonth OID. | 1.3.6.1.4.1.318.1.1.17.5.3.4 | INTEGER {applyLoadEveryTest(1), neverApplyLoad(2), applyLoadMonthly(3), applyLoadMonthlyDetailed(4)} | read-write | mandatory |
| xATSTestingScheduleTestWithLoadSelectMonth OBJECT-TYPE The detailed selection for testing with load on a month-by-month basis. This object is applicable when the xATSTestingScheduleTestWithLoadInterval is set to applyLoadMonthlyDetailed. Otherwise this selection will be ignored. Format for this string is a comma-separated entry of months. For example: Jan,Mar,Dec. The string will return 'No Months Scheduled' if no months have been selected. | 1.3.6.1.4.1.318.1.1.17.5.3.5 | DisplayString | read-write | mandatory |
| xATSTestingScheduleNextTestDate OBJECT-TYPE The date of the next scheduled test, in the format dd-mmm-yyyy. | 1.3.6.1.4.1.318.1.1.17.5.3.6 | DisplayString | read-only | mandatory |
| xATSTestingSimulatePowerFail OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.5.4 | |||
| xATSTestingSimulatePowerFailTest OBJECT-TYPE This object executes a simulated power failure for the duration indicated. Simulation can be aborted by selecting cancelSimulation. | 1.3.6.1.4.1.318.1.1.17.5.4.1 | INTEGER {cancelSimulation(1), fiveSecondsSimulation(2), tenSecondsSimulation(3), thirtySecondsSimulation(4), oneMinuteSimulation(5), threeMinutesSimulation(6), fiveMinutesSimulation(7), tenMinutesSimulation(8)} | read-write | mandatory |
| xATSTestingSimulatePowerFailTimeRemaining OBJECT-TYPE Indicates the time remaining in seconds, for a simulated power failure. a value of zero indicates that simulated power failure is not active. | 1.3.6.1.4.1.318.1.1.17.5.4.2 | INTEGER | read-only | mandatory |
| xATSInputContacts OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.6 | |||
| xATSInputContactNumContacts OBJECT-TYPE The number of contacts supported by the ATS. | 1.3.6.1.4.1.318.1.1.17.6.1 | INTEGER | read-only | mandatory |
| xATSInputContactTableSize OBJECT-TYPE The number of input contact entries. | 1.3.6.1.4.1.318.1.1.17.6.2 | INTEGER | read-only | mandatory |
| xATSInputContactTable OBJECT-TYPE A list of contacts supported by the ATS. The number of entries is contained in the xATSInputContactTableSize OID. | 1.3.6.1.4.1.318.1.1.17.6.3 | not-accessible | mandatory | |
| xATSInputContactEntry OBJECT-TYPE A contact entry containing information for a given contact. | 1.3.6.1.4.1.318.1.1.17.6.3.1 | not-accessible | mandatory | |
| xATSInputContactNumber OBJECT-TYPE An index identifying the contact on the ATS. | 1.3.6.1.4.1.318.1.1.17.6.3.1.1 | INTEGER | read-only | mandatory |
| xATSInputContactName OBJECT-TYPE The description of the purpose/use of the contact. | 1.3.6.1.4.1.318.1.1.17.6.3.1.2 | DisplayString | read-write | mandatory |
| xATSInputContactNormalState OBJECT-TYPE The normal operating position of the contact. | 1.3.6.1.4.1.318.1.1.17.6.3.1.3 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| xATSInputContactCurrentState OBJECT-TYPE This value indicates the current state of the contact. | 1.3.6.1.4.1.318.1.1.17.6.3.1.4 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| xATSOutputRelays OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.7 | |||
| xATSOutputRelayNumRelays OBJECT-TYPE The number of output relays supported by the ATS. | 1.3.6.1.4.1.318.1.1.17.7.1 | INTEGER | read-only | mandatory |
| xATSOutputRelayTableSize OBJECT-TYPE The number of output relay entries. | 1.3.6.1.4.1.318.1.1.17.7.2 | INTEGER | read-only | mandatory |
| xATSOutputRelayTable OBJECT-TYPE A list of output relays supported by the ATS. The number of entries is contained in the xATSOutputRelayTableSize OID. | 1.3.6.1.4.1.318.1.1.17.7.3 | not-accessible | mandatory | |
| xATSOutputRelayEntry OBJECT-TYPE A output relay entry containing information for a given contact. | 1.3.6.1.4.1.318.1.1.17.7.3.1 | not-accessible | mandatory | |
| xATSOutputRelayNumber OBJECT-TYPE An index identifying the output relay on the ATS. | 1.3.6.1.4.1.318.1.1.17.7.3.1.1 | INTEGER | read-only | mandatory |
| xATSOutputRelayName OBJECT-TYPE The description of the purpose/use of the output relay. | 1.3.6.1.4.1.318.1.1.17.7.3.1.2 | DisplayString | read-write | mandatory |
| xATSOutputRelayNormalState OBJECT-TYPE The normal operating position of the output relay. | 1.3.6.1.4.1.318.1.1.17.7.3.1.3 | INTEGER {open(1), closed(2)} | read-write | mandatory |
| xATSOutputRelayCurrentState OBJECT-TYPE This value indicates the current state of the output relay. | 1.3.6.1.4.1.318.1.1.17.7.3.1.4 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| xATSMisc OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.17.8 | |||
| generator OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18 | |||
| xATSGenerator OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1 | |||
| xATSGeneratorIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.1 | |||
| xATSGeneratorIdentModelNumber OBJECT-TYPE A character string identifying the model number of the generator. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.18.1.1.1 | DisplayString | read-only | mandatory |
| xATSGeneratorIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the generator. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.18.1.1.2 | DisplayString | read-only | mandatory |
| xATSGeneratorIdentDateofManufacture OBJECT-TYPE A character string identifying when the generator was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.18.1.1.3 | DisplayString | read-only | mandatory |
| xATSGeneratorIdentVoltageConfiguration OBJECT-TYPE The voltage for which the generator's alternator is designed. Specified in Volts line-to-line. | 1.3.6.1.4.1.318.1.1.18.1.1.4 | INTEGER | read-only | mandatory |
| xATSGeneratorIdentMaxPowerRating OBJECT-TYPE The max power rating of the generator. Specified in kW. | 1.3.6.1.4.1.318.1.1.18.1.1.5 | INTEGER | read-only | mandatory |
| xATSGeneratorIdentAlternatorFrequency OBJECT-TYPE The frequency for which the generator's alternator is designed. Specified in Hertz. | 1.3.6.1.4.1.318.1.1.18.1.1.6 | INTEGER | read-only | mandatory |
| xATSGeneratorStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.2 | |||
| xATSGeneratorStatusGeneratorName OBJECT-TYPE The name or label for the generator connected to the source 2 of the ATS. | 1.3.6.1.4.1.318.1.1.18.1.2.1 | DisplayString | read-write | mandatory |
| xATSGeneratorStatusOperational OBJECT-TYPE The operational status of the generator. unavailable when unrecognized status is received. | 1.3.6.1.4.1.318.1.1.18.1.2.2 | INTEGER {nocomm(1), off(2), ready(3), starting(4), idle(5), running(6), normalStop(7), emergencyStop(8), notInAuto(9), shutdown(10), unknown(11)} | read-only | mandatory |
| xATSGeneratorStatusModeSwitchPosition OBJECT-TYPE The position of the generator's auto-mode switch. In automatic mode, the generator is started and stopped via the remote start contact, which has state indicated in the xATSGeneratorStatusRemoteStart OID. In manual mode generator start/stop control is via local command only. Off prevents the generator from running. | 1.3.6.1.4.1.318.1.1.18.1.2.3 | INTEGER {off(1), manual(2), automatic(3), unknown(4)} | read-only | mandatory |
| xATSGeneratorStatusRemoteStart OBJECT-TYPE The status of the generator's remote start contact, which is provided as an output from the transfer switch to start/stop the generator when in automatic mode. | 1.3.6.1.4.1.318.1.1.18.1.2.4 | INTEGER {stop(1), run(2), unknown(3)} | read-only | mandatory |
| xATSGeneratorAdvStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.3 | |||
| xATSGeneratorAdvStatusBatteryVoltage OBJECT-TYPE The voltage of the generator's starting battery. Measured in tenths of VDC, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.3.1 | INTEGER | read-only | mandatory |
| xATSGeneratorAdvStatusOilPressure OBJECT-TYPE The generator's engine oil pressure. Measured in tenths of Psi or kPa, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.3.2 | INTEGER | read-only | mandatory |
| xATSGeneratorAdvStatusCoolantTemperature OBJECT-TYPE Current coolant temperature in the generator. Measured in degrees Celsius or Fahrenheit, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.3.3 | INTEGER | read-only | mandatory |
| xATSGeneratorAdvStatusEngineRPM OBJECT-TYPE Current engine speed of the generator. Measured in RPM, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.3.4 | INTEGER | read-only | mandatory |
| xATSGeneratorAdvStatusOilLevel OBJECT-TYPE Indicates adequate oil level in the generator. | 1.3.6.1.4.1.318.1.1.18.1.3.5 | INTEGER {ok(1), low(2), unknown(3)} | read-only | mandatory |
| xATSGeneratorAdvStatusCoolantLevel OBJECT-TYPE Indicates adequate coolant level in the generator. | 1.3.6.1.4.1.318.1.1.18.1.3.6 | INTEGER {ok(1), low(2), unknown(3)} | read-only | mandatory |
| xATSGeneratorOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.4 | |||
| xATSGeneratorOutputFrequency OBJECT-TYPE The output frequency of the generator. Measured in tenths of Hertz, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.1 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputTotalPower OBJECT-TYPE The total output power of the generator. Measured in tenths of tenths of kW, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.2 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputTotalApparentPower OBJECT-TYPE The total output power of the generator. Measured in tenths of kVA, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.3 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputTotalPowerFactor OBJECT-TYPE Indicates the total load power factor of the generator. A value of 100 representing a unity power factor (1.00), or -1 when if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.4 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputTableSize OBJECT-TYPE The number of generator output phase entries. | 1.3.6.1.4.1.318.1.1.18.1.4.5 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputPhaseTable OBJECT-TYPE A list of generator output table entries. The number of entries is contained in the xATSGeneratorOutputTableSize OID. | 1.3.6.1.4.1.318.1.1.18.1.4.6 | not-accessible | mandatory | |
| xATSGeneratorOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular generator output phase. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1 | not-accessible | mandatory | |
| xATSGeneratorOutputPhaseIndex OBJECT-TYPE Description of each generator output phase utilized in this device. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| xATSGeneratorOutputVoltageLtoL OBJECT-TYPE Line-to-line generator output voltage. Measured in Volts, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.2 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputVoltageLtoN OBJECT-TYPE Line-to-neutral generator output voltage. Measured in volts, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.3 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputPhaseCurrent OBJECT-TYPE Generator load current per phase. Measured in Amps, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.4 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputPower OBJECT-TYPE Generator output power per phase. Measured in tenths of kW, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.5 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputApparentPower OBJECT-TYPE Generator output power per phase. Measured in tenths of kVA, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.6 | INTEGER | read-only | mandatory |
| xATSGeneratorOutputPowerFactor OBJECT-TYPE Indicates the load power factor of the generator output per phase. A value of 100 representing a unity power factor (1.00), or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.4.6.1.7 | INTEGER | read-only | mandatory |
| xATSGeneratorSettings OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.5 | |||
| xATSGeneratorSettingsVoltageAdjust OBJECT-TYPE The voltage adjust of the generator. Specified in volts line-to-line, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.5.1 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsFrequencyAdjust OBJECT-TYPE The frequency adjust of the generator. Specified in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.18.1.5.2 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsStartDelay OBJECT-TYPE The delay, in seconds, after the remote run signal is activated before the generator's engine will be cranked to start, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.5.3 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsStopDelay OBJECT-TYPE The delay, in seconds, before the generator will stop after the remote run signal is deactivated, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.5.4 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsCrankCycleEnable OBJECT-TYPE When Crank Cycle is enabled, the engine will be cranked up to the time specified by the xATSGeneratorSettingsCrankTime OID. If the generator's engine does not start, there will be a pause as specified by the xATSGeneratorSettingsCrankRestTime OID before the engine will be cranked again. This cycle is repeated as specified by the xATSGeneratorSettingsNumberCrank OID. When crank cycle is disabled, the generator's engine will be cranked continuously until it starts. | 1.3.6.1.4.1.318.1.1.18.1.5.5 | INTEGER {disabled(1), enabled(2), unknown(3)} | read-only | mandatory |
| xATSGeneratorSettingsCrankTime OBJECT-TYPE The duration of engine cranking, in seconds, when starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.5.6 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsCrankRestTime OBJECT-TYPE The pause duration, in seconds, following an unsuccessful attempt to start the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.5.7 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsNumberCrank OBJECT-TYPE The number of failed crank attempts before giving up on starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.5.8 | INTEGER | read-only | mandatory |
| xATSGeneratorSettingsMetricUnit OBJECT-TYPE Specifies the use of metric units in generator related OIDs, as well as on all other interfaces including the generator's local interface. | 1.3.6.1.4.1.318.1.1.18.1.5.9 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| xATSGeneratorService OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.6 | |||
| xATSGeneratorServiceTotalRunHoursLifetime OBJECT-TYPE Total time that the generator engine has been run, over the life of the generator. Measured in hours. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.6.1 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceEngineStartsLifetime OBJECT-TYPE Number of engine starts over the life of the generator. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.6.2 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceTotalkWhLifetime OBJECT-TYPE Total kWh of operation over the life of the generator. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.6.3 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceTotalRunHoursSinceMaintenance OBJECT-TYPE Total time that the generator engine has been run, since last service maintenance. Measured in tenths of hours. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.6.4 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceEngineStartsSinceMaintenance OBJECT-TYPE Number of engine starts since last service maintenance. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.6.5 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceTotalkWhMaintenance OBJECT-TYPE Total kWh of operation since last service maintenance. -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.6.6 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceResetRecord OBJECT-TYPE Resets the engine start counter, engine run-hours, and kWh values that have accumulated in the generator since last maintenance. Also, the last service date will be reset to the current system date, and any service alarms will be cleared. | 1.3.6.1.4.1.318.1.1.18.1.6.7 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| xATSGeneratorServiceRecordResetDate OBJECT-TYPE Date at which the generator's service record was reset, in dd-mmm-yyyy format. | 1.3.6.1.4.1.318.1.1.18.1.6.8 | DisplayString | read-only | mandatory |
| xATSGeneratorServiceNextServiceDate OBJECT-TYPE Date at which the next generator service is due in dd-mmm-yyyy format. Based on the xATSGeneratorServiceCalendarIntervalThreshold OID or '' if the calendar-based threshold is set to off. | 1.3.6.1.4.1.318.1.1.18.1.6.9 | DisplayString | read-only | mandatory |
| xATSGeneratorServiceRunHoursUntilServiceDate OBJECT-TYPE Run hours until the next generator service is due, in hours. Based on the xATSGeneratorServiceRunHoursThreshold OID or -1 if the run hour-based threshold is set to off. | 1.3.6.1.4.1.318.1.1.18.1.6.10 | INTEGER | read-only | mandatory |
| xATSGeneratorServiceRunHoursThreshold OBJECT-TYPE Run hour-based service interval. When the run-hours since service surpasses this threshold, generator service is due. | 1.3.6.1.4.1.318.1.1.18.1.6.11 | INTEGER {disabled(1), runThreshold100Hours(2), runThreshold150Hours(3), runThreshold200Hours(4), runThreshold250Hours(5), runThreshold300Hours(6), runThreshold400Hours(7), runThreshold500Hours(8)} | read-write | mandatory |
| xATSGeneratorServiceCalendarIntervalThreshold OBJECT-TYPE Calendar-based service interval. When the next service date, as indicated by the xATSGeneratorServiceNextServiceDate OID is in the past, generator is due for service. | 1.3.6.1.4.1.318.1.1.18.1.6.12 | INTEGER {disabled(1), interval1month(2), interval2month(3), interval3month(4), interval6month(5), intervalyearly(6)} | read-write | mandatory |
| xATSGeneratorFuelSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.18.1.7 | |||
| xATSGeneratorFuelSystemType OBJECT-TYPE The type of fuel used by the generator. | 1.3.6.1.4.1.318.1.1.18.1.7.1 | INTEGER {diesel(1), propane(2), naturalGas(3), unknown(4)} | read-only | mandatory |
| xATSGeneratorFuelSystemTankSize OBJECT-TYPE Size of the generator's fuel tank. Specified in gallons or liters, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.7.2 | INTEGER | read-only | mandatory |
| xATSGeneratorFuelSystemFuelLevel OBJECT-TYPE Fuel remaining in the generator tank. Measured in percent of tank fill, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.7.3 | INTEGER | read-only | mandatory |
| xATSGeneratorFuelSystemRuntimePower OBJECT-TYPE The power value used in the runtime remaining calculation. Measured in tenths of kW, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.7.4 | INTEGER | read-only | mandatory |
| xATSGeneratorFuelSystemEstimatedRunTime OBJECT-TYPE An estimate of available runtime for the generator, based on available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID and kW load as specified in the xATSGeneratorFuelSystemRuntimePower OID. Measured in tenths of hours, or -1 if not available. | 1.3.6.1.4.1.318.1.1.18.1.7.5 | INTEGER | read-only | mandatory |
| xATSGeneratorFuelSystemLowRunTimeThreshold OBJECT-TYPE Threshold below which a low runtime alarm will exist. | 1.3.6.1.4.1.318.1.1.18.1.7.6 | INTEGER {disabled(1), oneHour(2), twoHours(3), threeHours(4), fourHours(5), fiveHours(6), sixHours(7), twelveHours(8), oneDay(9), twoDays(10), threeDays(11), fourDays(12), fiveDays(13), sixDays(14), sevenDays(15)} | read-write | mandatory |
| xATSGeneratorFuelSystemVeryLowRunTimeThreshold OBJECT-TYPE Threshold below which a very low runtime alarm will exist. | 1.3.6.1.4.1.318.1.1.18.1.7.7 | INTEGER {disabled(1), oneHour(2), twoHours(3), threeHours(4), fourHours(5), fiveHours(6), sixHours(7), twelveHours(8), oneDay(9), twoDays(10), threeDays(11), fourDays(12), fiveDays(13), sixDays(14), sevenDays(15)} | read-write | mandatory |
| xATSGeneratorFuelSystemLowFuelLevelThreshold OBJECT-TYPE Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill. | 1.3.6.1.4.1.318.1.1.18.1.7.8 | INTEGER (0..100) | read-write | mandatory |
| xATSGeneratorFuelSystemVeryLowFuelLevelThreshold OBJECT-TYPE Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill. | 1.3.6.1.4.1.318.1.1.18.1.7.9 | INTEGER (0..100) | read-write | mandatory |
| consolePortServer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19 | |||
| cpsAP930x OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1 | |||
| cpsAP930xSys OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.1 | |||
| apCPSpname OBJECT-TYPE The product's name. | 1.3.6.1.4.1.318.1.1.19.1.1.1 | DisplayString | read-only | mandatory |
| apCPSversion OBJECT-TYPE The firmware's version. | 1.3.6.1.4.1.318.1.1.19.1.1.2 | DisplayString | read-only | mandatory |
| apCPSPower OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.1.3 | |||
| apCPSPwNum OBJECT-TYPE The number of the power supplies. | 1.3.6.1.4.1.318.1.1.19.1.1.3.1 | Integer32 | read-only | mandatory |
| apCPSPw1 OBJECT-TYPE State of the first power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF. | 1.3.6.1.4.1.318.1.1.19.1.1.3.2 | INTEGER | read-only | mandatory |
| apCPSPw2 OBJECT-TYPE State of the second power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF. | 1.3.6.1.4.1.318.1.1.19.1.1.3.3 | INTEGER | read-only | mandatory |
| apCPSPcmcia OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.1.4 | |||
| apCPSNPcmcia OBJECT-TYPE Number of PCMCIA cards available. | 1.3.6.1.4.1.318.1.1.19.1.1.4.1 | Integer32 | read-only | mandatory |
| cpsCardIdentTable OBJECT-TYPE A table of PCMCIA card identifications. | 1.3.6.1.4.1.318.1.1.19.1.1.4.2 | not-accessible | mandatory | |
| cpsCardIdentEntry OBJECT-TYPE Identification information for a PCMCIA card. | 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1 | not-accessible | mandatory | |
| cpsCardIdentIndex OBJECT-TYPE Number to identify the socket Card. | 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.1 | Integer32 | read-only | mandatory |
| cpsCardIdentProd OBJECT-TYPE Product identification string. | 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.2 | DisplayString | read-only | mandatory |
| cpsCardIdentMan OBJECT-TYPE Manufacturer ID code. | 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.3 | DisplayString | read-only | mandatory |
| cpsCardIdentFunc OBJECT-TYPE Function ID code. | 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.4 | DisplayString | read-only | mandatory |
| cpsCardIdentPCI OBJECT-TYPE PCI ID | 1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.5 | DisplayString | read-only | mandatory |
| cpsCardConfTable OBJECT-TYPE A table of socket configuration information. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3 | not-accessible | mandatory | |
| cpsCardConfEntry OBJECT-TYPE Configuration information for a socket. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1 | not-accessible | mandatory | |
| cpsCardConfIndex OBJECT-TYPE Number to identify the socket PCMCIA. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.1 | Integer32 | read-only | mandatory |
| cpsCardConfPower OBJECT-TYPE Power Settings. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.2 | DisplayString | read-only | mandatory |
| cpsCardConfType OBJECT-TYPE Interface Type. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.3 | DisplayString | read-only | mandatory |
| cpsCardConfInter OBJECT-TYPE Interrupt number. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.4 | DisplayString | read-only | mandatory |
| cpsCardConfFunc OBJECT-TYPE Function. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.5 | DisplayString | read-only | mandatory |
| cpsCardConfCardv OBJECT-TYPE Card values. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.6 | DisplayString | read-only | mandatory |
| cpsCardConfPort1 OBJECT-TYPE I/O Port 1. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.7 | DisplayString | read-only | mandatory |
| cpsCardConfPort2 OBJECT-TYPE I/O Port 2. | 1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.8 | DisplayString | read-only | mandatory |
| cpsCardStatusTable OBJECT-TYPE A table of current socket status information. | 1.3.6.1.4.1.318.1.1.19.1.1.4.4 | not-accessible | mandatory | |
| cpsCardStatusEntry OBJECT-TYPE Current status information for a socket. | 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1 | not-accessible | mandatory | |
| cpsCardStatusIndex OBJECT-TYPE Number to identify the socket PCMCIA. | 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.1 | Integer32 (0..2) | read-only | mandatory |
| cpsCardStatusCard OBJECT-TYPE Current Card State. | 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.2 | DisplayString | read-only | mandatory |
| cpsCardStatusFunc OBJECT-TYPE Current Function. | 1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.3 | DisplayString | read-only | mandatory |
| apCPSFlashSize OBJECT-TYPE Total amount of flash memory in Mbytes. | 1.3.6.1.4.1.318.1.1.19.1.1.5 | Integer32 | read-only | mandatory |
| apCPSRAMSize OBJECT-TYPE Total amount of RAM in Mbytes. | 1.3.6.1.4.1.318.1.1.19.1.1.6 | Integer32 | read-only | mandatory |
| apCPSCPUfreq OBJECT-TYPE CPU clock in MHz. | 1.3.6.1.4.1.318.1.1.19.1.1.7 | Integer32 | read-only | mandatory |
| apCPSDevId OBJECT-TYPE The product's identifier. | 1.3.6.1.4.1.318.1.1.19.1.1.8 | DisplayString | read-only | mandatory |
| cpsAP930xConf OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2 | |||
| cpsHostName OBJECT-TYPE The Host Name. | 1.3.6.1.4.1.318.1.1.19.1.2.1 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsConsoleBanner OBJECT-TYPE The console banner. | 1.3.6.1.4.1.318.1.1.19.1.2.2 | DisplayString (SIZE(0..255)) | read-write | mandatory |
| cpsMotd OBJECT-TYPE The motd message. | 1.3.6.1.4.1.318.1.1.19.1.2.3 | DisplayString (SIZE(0..255)) | read-write | mandatory |
| cpsEthItf OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2.4 | |||
| cpsEthDhcpc OBJECT-TYPE 0 will indicate DHCP inactive, 1 will indicate DHCP active, 2 will indicate DHCP active and the last parameter is saved. | 1.3.6.1.4.1.318.1.1.19.1.2.4.1 | INTEGER | read-write | mandatory |
| cpsEthIPaddr OBJECT-TYPE This is the IP address of the Ethernet Interface. | 1.3.6.1.4.1.318.1.1.19.1.2.4.2 | IpAddress | read-write | mandatory |
| cpsEthIPmask OBJECT-TYPE The mask for the Ethernet network. | 1.3.6.1.4.1.318.1.1.19.1.2.4.3 | IpAddress | read-write | mandatory |
| cpsEthMTU OBJECT-TYPE The Maximum Transmission Unit size, which determines whether packets should be broken up. | 1.3.6.1.4.1.318.1.1.19.1.2.4.4 | Integer32 | read-write | mandatory |
| cpsEthIPaddr2 OBJECT-TYPE The Ethernet secondary IP address. | 1.3.6.1.4.1.318.1.1.19.1.2.4.5 | IpAddress | read-write | mandatory |
| cpsEthIPmask2 OBJECT-TYPE The Ethernet secondary IP mask. | 1.3.6.1.4.1.318.1.1.19.1.2.4.6 | IpAddress | read-write | mandatory |
| cpsNameService OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2.5 | |||
| cpsResolverOrder OBJECT-TYPE Specifies how host lookups are to be performed. Valid values : empty, 'hosts', 'bind', 'hosts, bind', 'bind, hosts' | 1.3.6.1.4.1.318.1.1.19.1.2.5.1 | DisplayString (SIZE(0..15)) | read-write | mandatory |
| cpsMultipleIP OBJECT-TYPE Valid values are ON or OFF. If set to ON, the resolve library will return all valid addresses for a host that appears in the /etc/hosts file, instead of only the first. | 1.3.6.1.4.1.318.1.1.19.1.2.5.2 | DisplayString (SIZE(0..3)) | read-write | mandatory |
| cpsDNSserv OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2.5.3 | |||
| cpsDNSpriserv OBJECT-TYPE Internet Address (in dot notation) of primary name server that the resolver should query. | 1.3.6.1.4.1.318.1.1.19.1.2.5.3.1 | IpAddress | read-write | mandatory |
| cpsDNSsecserv OBJECT-TYPE Internet Address (in dot notation) of secondary name server that the resolver should query. | 1.3.6.1.4.1.318.1.1.19.1.2.5.3.2 | IpAddress | read-write | mandatory |
| cpsDNSdomain OBJECT-TYPE Local domain name. | 1.3.6.1.4.1.318.1.1.19.1.2.5.3.3 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortConf OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2.6 | |||
| cpsSerialGlobal OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2.6.1 | |||
| cpsSerialInclude OBJECT-TYPE File used in centralized management. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.1 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialNFS OBJECT-TYPE Remote Network File System where data buffering will be written instead of the default directory '/var/run/DB'. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.2 | DisplayString (SIZE(0..50)) | read-write | mandatory |
| cpsSerialLockDir OBJECT-TYPE The lock directory. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.3 | DisplayString (SIZE(0..50)) | read-write | mandatory |
| cpsSerialRlogin OBJECT-TYPE Location of the rlogin binary that accepts the -i flag. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.4 | DisplayString (SIZE(0..50)) | read-write | mandatory |
| cpsSerialPppd OBJECT-TYPE Location of the pppd binary. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.5 | DisplayString (SIZE(0..50)) | read-write | mandatory |
| cpsSerialTelnet OBJECT-TYPE Location of the telnet application. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.6 | DisplayString (SIZE(0..50)) | read-write | mandatory |
| cpsSerialSsh OBJECT-TYPE Location of the ssh application. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.7 | DisplayString (SIZE(0..50)) | read-write | mandatory |
| cpsSerialLocalLogins OBJECT-TYPE This parameter is only necessary when authentication is being performed for a port. This is useful if the Radius authentication server is down. 0 indicates OFF, 1 indicates ON. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.8 | INTEGER | read-write | mandatory |
| cpsSerialFacility OBJECT-TYPE This value (0-7) is the Local facility sent to the syslog daemon. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.9 | Integer32 | read-write | mandatory |
| cpsSerialDBFacility OBJECT-TYPE This value (0-7) is the Local facility sent to the syslog daemon. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.10 | Integer32 | read-write | mandatory |
| cpsSerialGroupTable OBJECT-TYPE | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11 | not-accessible | mandatory | |
| cpsSerialGroupEntry OBJECT-TYPE | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1 | not-accessible | mandatory | |
| cpsSerialGroupIndex OBJECT-TYPE Number to identify the group. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.1 | INTEGER | read-only | mandatory |
| cpsSerialGroupName OBJECT-TYPE The group name. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.2 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| cpsSerialGroupUsers OBJECT-TYPE The user's names. | 1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.3 | DisplayString (SIZE(0..80)) | read-write | mandatory |
| cpsSerialSpec OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.2.6.2 | |||
| cpsSerialPortTable OBJECT-TYPE This is the specific configuration per serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1 | not-accessible | mandatory | |
| cpsSerialPortEntry OBJECT-TYPE One particular serial port configuration. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1 | not-accessible | mandatory | |
| cpsSerialPortNumber OBJECT-TYPE Number to identify the serial port. Value 0 is ALL. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.1 | INTEGER | read-only | mandatory |
| cpsSerialPortTty OBJECT-TYPE The device name for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.2 | DisplayString (SIZE(0..25)) | read-write | mandatory |
| cpsSerialPortName OBJECT-TYPE Alias name given to the server connected to the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.3 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortSpeed OBJECT-TYPE The speed of the serial port. Supported values are: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400, and 460800 | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.4 | Integer32 | read-write | mandatory |
| cpsSerialPortDataSize OBJECT-TYPE The data size for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.5 | Integer32 (4..8) | read-write | mandatory |
| cpsSerialPortStopBits OBJECT-TYPE The number of stop bits for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.6 | Integer32 (0..2) | read-write | mandatory |
| cpsSerialPortParity OBJECT-TYPE The parity for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.7 | DisplayString (SIZE(0..5)) | read-write | mandatory |
| cpsSerialPortFlowCtrl OBJECT-TYPE The flow control for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.8 | DisplayString (SIZE(0..5)) | read-write | mandatory |
| cpsSerialPortDTRdelay OBJECT-TYPE This specifies how long (in milliseconds) a DTR signal will be turned off before it is turned on again. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.9 | Integer32 | read-write | mandatory |
| cpsSerialPortDCDCtrl OBJECT-TYPE DCD signal controls the connection request. 0 will indicate nocontrol, 1 will indicate control. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.10 | INTEGER | read-write | mandatory |
| cpsSerialPortLogUtmp OBJECT-TYPE Update the login records in /var/run/utmp file. 0 will indicate inactive, 1 will indicate active. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.11 | INTEGER | read-write | mandatory |
| cpsSerialPortLogWtmp OBJECT-TYPE Update the login records in /var/run/wtmp file. 0 will indicate inactive, 1 will indicate active. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.12 | INTEGER | read-write | mandatory |
| cpsSerialPortLogform OBJECT-TYPE This is the format to write the login record. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.13 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortAuthtype OBJECT-TYPE Authentication type. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.14 | DisplayString (SIZE(0..25)) | read-write | mandatory |
| cpsSerialPortAuthSrv1 OBJECT-TYPE IP address of the primary authentication server. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.15 | IpAddress | read-write | mandatory |
| cpsSerialPortAccSrv1 OBJECT-TYPE IP address of the primary accounting server. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.16 | IpAddress | read-write | mandatory |
| cpsSerialPortAuthTmo OBJECT-TYPE This is the timeout (in seconds) for the authentication query to be answered. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.17 | Integer32 | read-write | mandatory |
| cpsSerialPortAuthRetr OBJECT-TYPE This defines the number of times each server is tried before another is contacted. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.18 | Integer32 | read-write | mandatory |
| cpsSerialPortAuthSrv2 OBJECT-TYPE IP address of the secondary authentication server. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.19 | IpAddress | read-write | mandatory |
| cpsSerialPortAccSrv2 OBJECT-TYPE IP address of the secondary accounting server. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.20 | IpAddress | read-write | mandatory |
| cpsSerialPortAuthSecret OBJECT-TYPE This is the shared secret with authentication servers. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.21 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortAuthRadP OBJECT-TYPE Radius state. 0 will indicate inactive, 1 will indicate active. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.22 | INTEGER | read-write | mandatory |
| cpsSerialPortAuthAcc OBJECT-TYPE Access restriction. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.23 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortProtocol OBJECT-TYPE Defines the serial port's protocol. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.24 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortRemoteIP OBJECT-TYPE This is the default IP address of the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.25 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| cpsSerialPortSocketPort OBJECT-TYPE This defines an alternative labeling system for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.26 | DisplayString (SIZE(0..10)) | read-write | mandatory |
| cpsSerialPortRemHost OBJECT-TYPE The IP address of the host to which the serial port will connect. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.27 | IpAddress | read-write | mandatory |
| cpsSerialPortBanner OBJECT-TYPE This defines the banner. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.28 | DisplayString (SIZE(0..250)) | read-write | mandatory |
| cpsSerialPortPrompt OBJECT-TYPE This defines the login prompt to the serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.29 | DisplayString (SIZE(0..250)) | read-write | mandatory |
| cpsSerialPortTermType OBJECT-TYPE This defines the terminal type. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.30 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| cpsSerialPortAutomUsr OBJECT-TYPE This defines the automatic user. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.31 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortNetMask OBJECT-TYPE The network mask used in dial in connection. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.32 | IpAddress | read-write | mandatory |
| cpsSerialPortPppMtu OBJECT-TYPE The PPP MTU - dial in connection. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.33 | Integer32 | read-write | mandatory |
| cpsSerialPortPppMru OBJECT-TYPE The PPP MRU - dial in connection. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.34 | Integer32 | read-write | mandatory |
| cpsSerialPortPppOptions OBJECT-TYPE The PPP options when the PPP session is autodetected. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.35 | DisplayString | read-write | mandatory |
| cpsSerialPortPppFoption OBJECT-TYPE The PPP forced options when the user has already been authenticated. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.36 | DisplayString | read-write | mandatory |
| cpsSerialPortModemChat OBJECT-TYPE The initchat send to modem connected. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.37 | DisplayString | read-write | mandatory |
| cpsSerialPortSttyCmd OBJECT-TYPE The tty settings after socket connection is established. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.38 | DisplayString (SIZE(0..180)) | read-write | mandatory |
| cpsSerialPortSockTx OBJECT-TYPE Defines the delay (in milliseconds) before transmission to the Ethernet of data received through a serial port. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.39 | Integer32 | read-write | mandatory |
| cpsSerialPortSockPoll OBJECT-TYPE Keep-alive timer (milliseconds) for the TCP connection. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.40 | Integer32 | read-write | mandatory |
| cpsSerialPortSockIdle OBJECT-TYPE The idle timeout in seconds. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.41 | Integer32 | read-write | mandatory |
| cpsSerialPortDBsize OBJECT-TYPE Maximum size of the data buffering file. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.42 | Integer32 | read-write | mandatory |
| cpsSerialPortDBtime OBJECT-TYPE Timestamp in data buffering. 0 will indicate inactive, 1 will indicate active. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.43 | INTEGER | read-write | mandatory |
| cpsSerialPortDBmode OBJECT-TYPE Data buffering mode : circ or line. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.44 | DisplayString (SIZE(0..5)) | read-write | mandatory |
| cpsSerialPortDBsyslog OBJECT-TYPE Size of the data buffer sent to syslog. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.45 | Integer32 | read-write | mandatory |
| cpsSerialPortDBmenu OBJECT-TYPE Menu type for data buffering. 0 will indicate display Menu, 1 will indicate inactive, 2 will indicate DB, 3 will indicate Parc. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.46 | INTEGER | read-write | mandatory |
| cpsSerialPortDBalarm OBJECT-TYPE Alarm generation status. 0 will indicate inactive, 1 will indicate active. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.47 | INTEGER | read-write | mandatory |
| cpsSerialPortSSHbreak OBJECT-TYPE Break sequence - ssh session. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.48 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| cpsSerialPortSniffSess OBJECT-TYPE Sniff session type. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.49 | DisplayString (SIZE(0..5)) | read-write | mandatory |
| cpsSerialPortSniffAdm OBJECT-TYPE List of admin users allowed to sniff session. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.50 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortSniffEsc OBJECT-TYPE Escape sequence used in sniff session. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.51 | DisplayString (SIZE(0..6)) | read-write | mandatory |
| cpsSerialPortSniffMsess OBJECT-TYPE | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.52 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| cpsSerialPortTelnetMode OBJECT-TYPE Mode negotiated by client telnet with the server. 0 will indicate text, 1 will indicate binary. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.53 | INTEGER | read-write | mandatory |
| cpsSerialPortSysBufSess OBJECT-TYPE Syslog Buffering at all times. 0 will indicate yes, 1 will indicate no. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.54 | INTEGER | read-write | mandatory |
| cpsSerialPortLFSuppress OBJECT-TYPE LF suppression in socket_server session. 0 will indicate inactive, 1 will indicate active. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.55 | INTEGER | read-write | mandatory |
| cpsSerialPortAutoInput OBJECT-TYPE Input string used for auto answer. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.56 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortAutoOutput OBJECT-TYPE Output string used for auto answer. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.57 | DisplayString (SIZE(0..40)) | read-write | mandatory |
| cpsSerialPortBreakInterval OBJECT-TYPE The break interval in milliseconds. | 1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.58 | Integer32 | read-write | mandatory |
| cpsAP930xInfo OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.3 | |||
| cpsInfoSerialPortTable OBJECT-TYPE This is the information of the specific serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1 | not-accessible | mandatory | |
| cpsInfoSerialPortEntry OBJECT-TYPE One particular serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1 | not-accessible | mandatory | |
| cpsInfoSerialPortNumber OBJECT-TYPE Number to identify the serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.1 | INTEGER | read-only | mandatory |
| cpsInfoSerialPortTty OBJECT-TYPE The device name for the serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.2 | DisplayString | read-only | mandatory |
| cpsInfoSerialPortName OBJECT-TYPE Alias name given to the server connected to the serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.3 | DisplayString | read-only | mandatory |
| cpsInfoSerialPortSpeed OBJECT-TYPE The speed for serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.4 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortTxBytes OBJECT-TYPE The number of transmitted bytes by the serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.5 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortRXBytes OBJECT-TYPE The number of received bytes by the serial port. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.6 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortErrFrame OBJECT-TYPE The number of frame errors. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.7 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortErrParity OBJECT-TYPE The number of parity errors. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.8 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortErrBreaks OBJECT-TYPE The number of breaks errors. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.9 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortErrOverrun OBJECT-TYPE The number of overrun errors. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.10 | Integer32 | read-only | mandatory |
| cpsInfoSerialPortSigDTR OBJECT-TYPE The state of the DTR signal. 0 will indicate down, 1 will indicate up. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.11 | INTEGER | read-only | mandatory |
| cpsInfoSerialPortSigCD OBJECT-TYPE The state of the DCD signal. 0 will indicate down, 1 will indicate up. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.12 | INTEGER | read-only | mandatory |
| cpsInfoSerialPortSigDSR OBJECT-TYPE The state of the DSR signal. 0 will indicate down, 1 will indicate up. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.13 | INTEGER | read-only | mandatory |
| cpsInfoSerialPortSigRTS OBJECT-TYPE The state of the RTS signal. 0 will indicate down, 1 will indicate up. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.14 | INTEGER | read-only | mandatory |
| cpsInfoSerialPortSigCTS OBJECT-TYPE The state of the CTS signal. 0 will indicate down, 1 will indicate up. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.15 | INTEGER | read-only | mandatory |
| cpsInfoSerialPortSigRI OBJECT-TYPE The state of the RI signal. 0 will indicate down, 1 will indicate up. | 1.3.6.1.4.1.318.1.1.19.1.3.1.1.16 | INTEGER | read-only | mandatory |
| cpsAP930xAdm OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.19.1.4 | |||
| apCPSSave OBJECT-TYPE Exec saveconf command. 0 will indicate don't save, 1 will indicate save. | 1.3.6.1.4.1.318.1.1.19.1.4.1 | INTEGER | read-write | mandatory |
| apCPSSerialHUP OBJECT-TYPE Exec signal_ras hup command. 0 will indicate no restart, 1 will indicate restart. | 1.3.6.1.4.1.318.1.1.19.1.4.2 | INTEGER | read-write | mandatory |
| accessControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20 | |||
| accessPX OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1 | |||
| accessPXIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.1 | |||
| accessPXIdentAlarmStatus OBJECT-TYPE Access PX alarm status 1 = Normal 2 = Warning 3 = Critical. | 1.3.6.1.4.1.318.1.1.20.1.1.1 | INTEGER | read-only | mandatory |
| accessPXIdentProductNumber OBJECT-TYPE The product number of the Access PX. | 1.3.6.1.4.1.318.1.1.20.1.1.2 | DisplayString | read-only | mandatory |
| accessPXIdentHardwareRev OBJECT-TYPE The hardware revision number of the Access PX. | 1.3.6.1.4.1.318.1.1.20.1.1.3 | DisplayString | read-only | mandatory |
| accessPXIdentDateOfManufacture OBJECT-TYPE The date of manufacture of the Access PX. | 1.3.6.1.4.1.318.1.1.20.1.1.4 | DisplayString | read-only | mandatory |
| accessPXIdentSerialNumber OBJECT-TYPE The serial number of the Access PX. | 1.3.6.1.4.1.318.1.1.20.1.1.5 | DisplayString | read-only | mandatory |
| accessPXConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.2 | |||
| accessPXConfigCardReaderEnableDisableAction OBJECT-TYPE Action to disable/enable the card reader. | 1.3.6.1.4.1.318.1.1.20.1.2.1 | INTEGER {disabled(1), enable(2)} | read-write | mandatory |
| accessPXConfigAutoRelockTime OBJECT-TYPE Time (10 - 60) in seconds when the door will automatically relock after it has been unlocked and the handle has not been opened. | 1.3.6.1.4.1.318.1.1.20.1.2.2 | INTEGER | read-write | mandatory |
| accessPXConfigCardFormat OBJECT-TYPE Indicates and controls the various card format. | 1.3.6.1.4.1.318.1.1.20.1.2.3 | INTEGER {hidStd26(1), hid37Bit(2), hid37BitWithFacility(3), hidCorp1000(4), mifareclassic4b(5), mifareclassic7b(6), mifaredesfire(7), mifareplus(8), iCLASS8b(9)} | read-write | mandatory |
| accessPXConfigFront OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.3 | |||
| accessPXConfigFrontDoorLockControl OBJECT-TYPE Control action (unlock, lock) for the front door. Setting this OID will unlock or lock the front door. Getting this OID will respond with the current state of the front door lock which could be 1 = unlocked, 2 = locked, 3 = not installed, 4 = disconnected. | 1.3.6.1.4.1.318.1.1.20.1.3.1 | INTEGER {unlock(1), lock(2), notInstalledReadOnly(3), disconnectedReadOnly(4)} | read-write | mandatory |
| accessPXConfigFrontDoorMaxOpenTime OBJECT-TYPE Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition. | 1.3.6.1.4.1.318.1.1.20.1.3.2 | INTEGER | read-write | mandatory |
| accessPXStatusFront OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.4 | |||
| accessPXStatusFrontDoorLock OBJECT-TYPE Present state of the front door lock: unlocked, locked, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.4.1 | INTEGER {unlocked(1), locked(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| accessPXStatusFrontDoor OBJECT-TYPE Present state of the front door: open, closed, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.4.2 | INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| accessPXStatusFrontDoorHandle OBJECT-TYPE Present state of the front door handle: open, closed, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.4.3 | INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| accessPXStatusFrontDoorMaxOpenTime OBJECT-TYPE Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition. | 1.3.6.1.4.1.318.1.1.20.1.4.4 | INTEGER | read-only | mandatory |
| accessPXStatusFrontDoorAlarmStatus OBJECT-TYPE Front door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Front door not installed. | 1.3.6.1.4.1.318.1.1.20.1.4.5 | INTEGER | read-only | mandatory |
| accessPXConfigRear OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.5 | |||
| accessPXConfigRearDoorLockControl OBJECT-TYPE Control action (unlock, lock) for the rear door. Setting this OID will unlock or lock the rear door. Getting this OID will respond with the current state of the rear door lock which could be 1 = unlocked, 2 = locked, 3 = not installed, 4 = disconnected. | 1.3.6.1.4.1.318.1.1.20.1.5.1 | INTEGER {unlock(1), lock(2), notInstalledReadOnly(3), disconnectedReadOnly(4)} | read-write | mandatory |
| accessPXConfigRearDoorMaxOpenTime OBJECT-TYPE Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition. | 1.3.6.1.4.1.318.1.1.20.1.5.2 | INTEGER | read-write | mandatory |
| accessPXStatusRear OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.6 | |||
| accessPXStatusRearDoorLock OBJECT-TYPE Present state of the rear door lock: unlocked, locked, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.6.1 | INTEGER {unlocked(1), locked(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| accessPXStatusRearDoor OBJECT-TYPE Present state of the rear door: open, closed, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.6.2 | INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| accessPXStatusRearDoorHandle OBJECT-TYPE Present state of the rear door handle: open, closed, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.6.3 | INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| accessPXStatusRearDoorMaxOpenTime OBJECT-TYPE Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition. | 1.3.6.1.4.1.318.1.1.20.1.6.4 | INTEGER | read-only | mandatory |
| accessPXStatusRearDoorAlarmStatus OBJECT-TYPE Rear door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Rear door not installed. | 1.3.6.1.4.1.318.1.1.20.1.6.5 | INTEGER | read-only | mandatory |
| accessPXConfigBeacon OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.7 | |||
| accessPXConfigBeaconName OBJECT-TYPE A descriptive name for the Beacon. | 1.3.6.1.4.1.318.1.1.20.1.7.1 | DisplayString | read-write | mandatory |
| accessPXConfigBeaconLocation OBJECT-TYPE A descriptive name for the location of the Beacon. | 1.3.6.1.4.1.318.1.1.20.1.7.2 | DisplayString | read-write | mandatory |
| accessPXConfigBeaconAction OBJECT-TYPE Control action (turnOff, turnOn) for the beacon. Setting this OID will turn the beacon off or on. Getting this OID will respond with the current state which could be 1 = off, 2 = on, 3 = not installed, 4 = disconnected. | 1.3.6.1.4.1.318.1.1.20.1.7.3 | INTEGER {turnOff(1), turnOn(2), notInstalledReadOnly(3), disconnectedReadOnly(4)} | read-write | mandatory |
| accessPXStatusBeacon OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.20.1.8 | |||
| accessPXStatusBeaconName OBJECT-TYPE The name of the beacon. | 1.3.6.1.4.1.318.1.1.20.1.8.1 | DisplayString | read-only | mandatory |
| accessPXStatusBeaconLocation OBJECT-TYPE The name of the location of the beacon. | 1.3.6.1.4.1.318.1.1.20.1.8.2 | DisplayString | read-only | mandatory |
| accessPXStatusBeaconCurrentState OBJECT-TYPE The current state of the beacon: off, on, not installed, or disconnected. | 1.3.6.1.4.1.318.1.1.20.1.8.3 | INTEGER {off(1), on(2), notInstalled(3), disconnected(4)} | read-only | mandatory |
| apcLocalDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.21 | |||
| apcLocalDisplayIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.21.1 | |||
| apcLocalDisplayIdentDisplayType OBJECT-TYPE Numeric value used to identify the type of display in use. | 1.3.6.1.4.1.318.1.1.21.1.1 | INTEGER {noDisplayFound(1), powerviewRM(2), powerviewWW(3)} | read-only | mandatory |
| apcLocalDisplayIdentModelNumber OBJECT-TYPE The model number of the local display. | 1.3.6.1.4.1.318.1.1.21.1.2 | DisplayString | read-only | mandatory |
| apcLocalDisplayIdentFirmwareRev OBJECT-TYPE The firmware revision number of the local display. | 1.3.6.1.4.1.318.1.1.21.1.3 | DisplayString | read-only | mandatory |
| apcLocalDisplayIdentOptions OBJECT-TYPE A display-specific string identifying options in the local display. | 1.3.6.1.4.1.318.1.1.21.1.4 | DisplayString | read-only | mandatory |
| apcLocalDisplayIdentDateOfManufacture OBJECT-TYPE The date of manufacture of the local display, if available. | 1.3.6.1.4.1.318.1.1.21.1.5 | DisplayString | read-only | mandatory |
| apcLocalDisplayIdentSerialNumber OBJECT-TYPE The serial number of the local display, if available. | 1.3.6.1.4.1.318.1.1.21.1.6 | DisplayString | read-only | mandatory |
| apcLocalDisplayConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.21.2 | |||
| apcLocalDisplayConfigAlarmBeeper OBJECT-TYPE The alarm beeper setting for the local display. When enabled, the alarm beeper will begin to sound whenever there a new alarm becomes active. The alarm beeper will continue to periodically sound until a key is pressed on the display. | 1.3.6.1.4.1.318.1.1.21.2.1 | INTEGER {beeperDisabled(1), beeperEnabled(2)} | read-write | mandatory |
| apcLocalDisplayConfigBeeperVolume OBJECT-TYPE The volume setting of the beeper on the local display. | 1.3.6.1.4.1.318.1.1.21.2.2 | INTEGER {beeperDisabled(1), beeperLow(2), beeperMedium(3), beeperHigh(4)} | read-write | mandatory |
| apcLocalDisplayConfigCheckLogIndicator OBJECT-TYPE The minimum level event severity level required to illuminate the check log light on the local display. notPresent (1) indicates that the display does not have a check log light. | 1.3.6.1.4.1.318.1.1.21.2.3 | INTEGER {checklogNotPresent(1), checklogDisabled(2), checklogInformational(3), checklogWarning(4), checklogCritical(5)} | read-write | mandatory |
| apcLocalDisplayConfigKeyClick OBJECT-TYPE The key click setting of the local display. | 1.3.6.1.4.1.318.1.1.21.2.4 | INTEGER {keyclickDisabled(1), keyclickEnabled(2)} | read-write | mandatory |
| apcLocalDisplayConfigContrast OBJECT-TYPE The contrast level of the local display. | 1.3.6.1.4.1.318.1.1.21.2.5 | INTEGER {contrast1(1), contrast2(2), contrast3(3), contrast4(4), contrast5(5), contrast6(6), contrast7(7), contrast8(8)} | read-write | mandatory |
| isxModularDistribution OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22 | |||
| isxModularDistInfo OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.1 | |||
| isxModularDistInfoTableSize OBJECT-TYPE The number of entries in the isxModularDistInfoTable. | 1.3.6.1.4.1.318.1.1.22.1.1 | INTEGER | read-only | mandatory |
| isxModularDistInfoTable OBJECT-TYPE Allows for getting information about the modular distribution metering equipment. | 1.3.6.1.4.1.318.1.1.22.1.2 | not-accessible | mandatory | |
| isxModularDistInfoEntry OBJECT-TYPE An entry containing information about an individual metering segment. | 1.3.6.1.4.1.318.1.1.22.1.2.1 | not-accessible | mandatory | |
| isxModularDistInfoSegmentIndex OBJECT-TYPE The index of the metering segment. | 1.3.6.1.4.1.318.1.1.22.1.2.1.1 | INTEGER | read-only | mandatory |
| isxModularDistInfoMeterModelNumber OBJECT-TYPE The model number of the metering board for this segment. | 1.3.6.1.4.1.318.1.1.22.1.2.1.2 | DisplayString | read-only | mandatory |
| isxModularDistInfoMeterSerialNumber OBJECT-TYPE The serial number of the metering board for this segment. | 1.3.6.1.4.1.318.1.1.22.1.2.1.3 | DisplayString | read-only | mandatory |
| isxModularDistInfoMeterDateOfManufacture OBJECT-TYPE The date of manufacture for the metering board for this segment, in the format mm/dd/yyyy. | 1.3.6.1.4.1.318.1.1.22.1.2.1.4 | DisplayString | read-only | mandatory |
| isxModularDistInfoMeterFirmwareRev OBJECT-TYPE The firmware revision number of the metering board for this segment. | 1.3.6.1.4.1.318.1.1.22.1.2.1.5 | DisplayString | read-only | mandatory |
| isxModularDistInfoMeterHardwareRev OBJECT-TYPE The hardware revision number of the metering board for this segment. | 1.3.6.1.4.1.318.1.1.22.1.2.1.6 | DisplayString | read-only | mandatory |
| isxModularDistModules OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.2 | |||
| isxModularDistModuleInfoTableSize OBJECT-TYPE The number of entries in the isxModularDistModuleInfoTable. | 1.3.6.1.4.1.318.1.1.22.2.1 | INTEGER | read-only | mandatory |
| isxModularDistModuleInfoTable OBJECT-TYPE Allows for getting basic information about the distribution modules installed in the system. | 1.3.6.1.4.1.318.1.1.22.2.2 | not-accessible | mandatory | |
| isxModularDistModuleInfoEntry OBJECT-TYPE An entry containing information about a specific distribution module. | 1.3.6.1.4.1.318.1.1.22.2.2.1 | not-accessible | mandatory | |
| isxModularDistModuleInfoModIndex OBJECT-TYPE The number of the distribution module. | 1.3.6.1.4.1.318.1.1.22.2.2.1.1 | INTEGER | read-only | mandatory |
| isxModularDistModuleInfoAlarmStatus OBJECT-TYPE The status of this module. This reflects the indicator lamp(s) on the front of the module. A value of notPresent indicates that the module is not installed. A value of unknown indicates that there is no communication with the metering segment for this module. | 1.3.6.1.4.1.318.1.1.22.2.2.1.2 | INTEGER {normal(1), warning(2), critical(3), notPresent(4), unknown(5)} | read-only | mandatory |
| isxModularDistModuleInfoModelNumber OBJECT-TYPE The model number of the distribution module. | 1.3.6.1.4.1.318.1.1.22.2.2.1.3 | DisplayString | read-only | mandatory |
| isxModularDistModuleInfoSerialNumber OBJECT-TYPE The serial number of the distribution module. | 1.3.6.1.4.1.318.1.1.22.2.2.1.4 | DisplayString | read-only | mandatory |
| isxModularDistModuleInfoDateOfManufacture OBJECT-TYPE The date that the distribution module was manufactured. | 1.3.6.1.4.1.318.1.1.22.2.2.1.5 | DisplayString | read-only | mandatory |
| isxModularDistModuleInfoNumCables OBJECT-TYPE The number of cables provided by this distribution module. | 1.3.6.1.4.1.318.1.1.22.2.2.1.6 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerTableSize OBJECT-TYPE The number of entries in the isxModularDistModuleBreakerTable. | 1.3.6.1.4.1.318.1.1.22.2.3 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerTable OBJECT-TYPE Allows for getting operational information about the distribution modules. | 1.3.6.1.4.1.318.1.1.22.2.4 | not-accessible | mandatory | |
| isxModularDistModuleBreakerEntry OBJECT-TYPE An entry containing information about a specific distribution modules and circuit breakers. | 1.3.6.1.4.1.318.1.1.22.2.4.1 | not-accessible | mandatory | |
| isxModularDistModuleBreakerModIndex OBJECT-TYPE The distribution module number. | 1.3.6.1.4.1.318.1.1.22.2.4.1.1 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerPhaseIndex OBJECT-TYPE The index to an individual breaker in the distribution module. The index also corresponds to the system phase to which the breaker is attached. | 1.3.6.1.4.1.318.1.1.22.2.4.1.2 | INTEGER {phaseL1(1), phaseL2(2), phaseL3(3)} | read-only | mandatory |
| isxModularDistModuleBreakerAlarmStatus OBJECT-TYPE This is a bit map representing the active alarms for this breaker: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) b4 - Breaker is open (critical) If a bit is set, the corresponding alarm is active. | 1.3.6.1.4.1.318.1.1.22.2.4.1.3 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerRating OBJECT-TYPE The current rating of the breaker. | 1.3.6.1.4.1.318.1.1.22.2.4.1.4 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerPhysicalGroup OBJECT-TYPE Numeric value used to indicate that a breaker is a part of a multi-pole breaker. Breakers within a distribution module, with equivalent physical group numbers, may have their handles physically tied together. A value of 1 indicates breakers that are physically tied together as part of a multi-pole breaker. A value of 0 indicates a single-handle breaker that is not physically tied to another breaker. | 1.3.6.1.4.1.318.1.1.22.2.4.1.5 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerCableNum OBJECT-TYPE Numeric value used to indicate the distribution cable to which this breaker is connected. These distribution cables are described in the table isxModularDistModuleOutputTable, and indexed by the OID isxModularDistModuleOutputCordIndex. | 1.3.6.1.4.1.318.1.1.22.2.4.1.6 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerPosition OBJECT-TYPE The physical status of this breaker pole, either closed or open (including tripped). | 1.3.6.1.4.1.318.1.1.22.2.4.1.7 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| isxModularDistModuleBreakerPositionAlarms OBJECT-TYPE Enable or disable breaker position alarms for this circuit breaker. | 1.3.6.1.4.1.318.1.1.22.2.4.1.8 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistModuleBreakerCurrent OBJECT-TYPE The current flowing though this breaker. Measured in tenths of amps. | 1.3.6.1.4.1.318.1.1.22.2.4.1.9 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerPercent OBJECT-TYPE The loading on this breaker as a percentage of the breaker's current rating. Expressed in tenths of percent. | 1.3.6.1.4.1.318.1.1.22.2.4.1.10 | INTEGER | read-only | mandatory |
| isxModularDistModuleBreakerPower OBJECT-TYPE The power being supplied through this breaker. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.22.2.4.1.11 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputsTableSize OBJECT-TYPE The number of entries in the isxModularDistModuleOutputTable. | 1.3.6.1.4.1.318.1.1.22.2.5 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputTable OBJECT-TYPE Allows for getting and setting information related to the load equipment being fed by the distribution modules in the ISX Modular Distribution System. | 1.3.6.1.4.1.318.1.1.22.2.6 | not-accessible | mandatory | |
| isxModularDistModuleOutputEntry OBJECT-TYPE An entry containing information about a specific distribution module and its output distribution cables. | 1.3.6.1.4.1.318.1.1.22.2.6.1 | not-accessible | mandatory | |
| isxModularDistModuleOutputModIndex OBJECT-TYPE The number of the distribution module supplying power to the load equipment. | 1.3.6.1.4.1.318.1.1.22.2.6.1.1 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputNumCables OBJECT-TYPE The number of distribution cables provided by this module. | 1.3.6.1.4.1.318.1.1.22.2.6.1.2 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputCordIndex OBJECT-TYPE The index of an individual distribution cable supplied by this module. | 1.3.6.1.4.1.318.1.1.22.2.6.1.3 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputName OBJECT-TYPE A string describing the load equipment being supplied by this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.4 | DisplayString | read-write | mandatory |
| isxModularDistModuleOutputLocation OBJECT-TYPE A string describing the location of equipment being supplied by distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.5 | DisplayString | read-write | mandatory |
| isxModularDistModuleOutputStatus OBJECT-TYPE This reflects the worse case severity for alarms associated with this distribution cable. A value of notPresent indicates that the cable does not exist for this module. A value of unknown indicates that the there is no communication with the metering segment for this distribution cable's module. | 1.3.6.1.4.1.318.1.1.22.2.6.1.6 | INTEGER {normal(1), warning(2), critical(3), notPresent(4), unknown(6)} | read-only | mandatory |
| isxModularDistModuleOutputAlarmGeneration OBJECT-TYPE Enable or disable all alarm generation related to this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.7 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistModuleOutputBreakerMap OBJECT-TYPE This is a bit map representing the breaker poles within the module that are associated with this distribution cable. The following 3 bits are used to indicate the indices of the breakers feeding the cable: b0 - Module breaker L1 b1 - Module breaker L2 b2 - Module breaker L3 If a bit is set, the breaker is used to feed this distribution cable. These breakers are described in the table isxModularDistModuleBreakerTable, and indexed by the OID isxModularDistModuleBreakerPhaseIndex. | 1.3.6.1.4.1.318.1.1.22.2.6.1.8 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputThresholdMin OBJECT-TYPE When the current drops below this value a critical alarm will exist. | 1.3.6.1.4.1.318.1.1.22.2.6.1.9 | INTEGER | read-write | mandatory |
| isxModularDistModuleOutputThresholdLow OBJECT-TYPE When the current drops below this value a warning alarm will exist. | 1.3.6.1.4.1.318.1.1.22.2.6.1.10 | INTEGER | read-write | mandatory |
| isxModularDistModuleOutputThresholdHigh OBJECT-TYPE When the current exceeds this value a warning alarm will exist. | 1.3.6.1.4.1.318.1.1.22.2.6.1.11 | INTEGER | read-write | mandatory |
| isxModularDistModuleOutputThresholdMax OBJECT-TYPE When the current exceeds this value a critical alarm will exist. | 1.3.6.1.4.1.318.1.1.22.2.6.1.12 | INTEGER | read-write | mandatory |
| isxModularDistModuleOutputAlarmMinEnable OBJECT-TYPE Enable or disable minimum current alarm generation for this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.13 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistModuleOutputAlarmLowEnable OBJECT-TYPE Enable or disable low current alarm generation for this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.14 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistModuleOutputAlarmHighEnable OBJECT-TYPE Enable or disable high current alarm generation for this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.15 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistModuleOutputAlarmMaxEnable OBJECT-TYPE Enable or disable maximum current alarm generation for this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.16 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistModuleOutputCableLength OBJECT-TYPE The length of this distribution cable. Specified in tenths of meters. | 1.3.6.1.4.1.318.1.1.22.2.6.1.17 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputConnectorType OBJECT-TYPE A string describing the connector on the end of this distribution cable. | 1.3.6.1.4.1.318.1.1.22.2.6.1.18 | DisplayString | read-only | mandatory |
| isxModularDistModuleOutputAvailableVoltages OBJECT-TYPE This is a bit map representing the voltages that are available at the connector. 6 bits are used to indicate the following: b0 - L1 b1 - L2 b2 - L3 b3 - L1-2 b4 - L2-3 b5 - L3-1 | 1.3.6.1.4.1.318.1.1.22.2.6.1.19 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputTotalPower OBJECT-TYPE The total power being consumed by the load equipment supplied by this distribution cable. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.22.2.6.1.20 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputKwhUsage OBJECT-TYPE The total energy consumed by the load equipment fed by this distribution cable. This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate OID, and may be cleared using the isxModularDistModuleOutputKwhReset OID. Measured in tenths of kWh. | 1.3.6.1.4.1.318.1.1.22.2.6.1.21 | INTEGER | read-only | mandatory |
| isxModularDistModuleOutputKwhReset OBJECT-TYPE Writing yes to this OID will reset the total kWh usage shown in the isxModularDistModuleOutputKwhUsage OID. | 1.3.6.1.4.1.318.1.1.22.2.6.1.22 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| isxModularDistModuleOutputKwhResetDate OBJECT-TYPE The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000. | 1.3.6.1.4.1.318.1.1.22.2.6.1.23 | DisplayString | read-only | mandatory |
| isxModularDistSubFeeds OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.3 | |||
| isxModularDistSubFeedInfoTableSize OBJECT-TYPE The number of entries in the isxModularDistSubFeedInfoTable. | 1.3.6.1.4.1.318.1.1.22.3.1 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedInfoTable OBJECT-TYPE Allows for getting information about distribution subfeed breakers. | 1.3.6.1.4.1.318.1.1.22.3.2 | not-accessible | mandatory | |
| isxModularDistSubFeedInfoEntry OBJECT-TYPE An entry containing information about a specific distribution subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1 | not-accessible | mandatory | |
| isxModularDistSubFeedInfoSubIndex OBJECT-TYPE The index of an individual subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.1 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedInfoName OBJECT-TYPE A string describing the load equipment being supplied by this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.2 | DisplayString | read-write | mandatory |
| isxModularDistSubFeedInfoLocation OBJECT-TYPE A string describing the location of the equipment being supplied by this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.3 | DisplayString | read-write | mandatory |
| isxModularDistSubFeedInfoBreakerRating OBJECT-TYPE The current rating of this subfeed breaker. | 1.3.6.1.4.1.318.1.1.22.3.2.1.4 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedInfoBreakerPosition OBJECT-TYPE The operational status of this breaker, either closed or open (including tripped). | 1.3.6.1.4.1.318.1.1.22.3.2.1.5 | INTEGER {open(1), closed(2)} | read-only | mandatory |
| isxModularDistSubFeedInfoAlarmStatus OBJECT-TYPE The worst case alarm status for this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.6 | INTEGER {normal(1), warning(2), critical(3)} | read-only | mandatory |
| isxModularDistSubFeedInfoAlarmGeneration OBJECT-TYPE Enable or disable all alarm generation related to this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.7 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoThresholdMin OBJECT-TYPE When the current drops below this value a critical alarm will exist. | 1.3.6.1.4.1.318.1.1.22.3.2.1.8 | INTEGER | read-write | mandatory |
| isxModularDistSubFeedInfoThresholdLow OBJECT-TYPE When the current drops below this value a warning alarm will exist. | 1.3.6.1.4.1.318.1.1.22.3.2.1.9 | INTEGER | read-write | mandatory |
| isxModularDistSubFeedInfoThresholdHigh OBJECT-TYPE When the current exceeds this value a warning alarm will exist. | 1.3.6.1.4.1.318.1.1.22.3.2.1.10 | INTEGER | read-write | mandatory |
| isxModularDistSubFeedInfoThresholdMax OBJECT-TYPE When the current exceeds this value a critical alarm will exist. | 1.3.6.1.4.1.318.1.1.22.3.2.1.11 | INTEGER | read-write | mandatory |
| isxModularDistSubFeedInfoAlarmMinEnable OBJECT-TYPE Enable or disable minimum current alarm generation for this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.12 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoAlarmLowEnable OBJECT-TYPE Enable or disable low current alarm generation for this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.13 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoAlarmHighEnable OBJECT-TYPE Enable or disable high current alarm generation for this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.14 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoAlarmMaxEnable OBJECT-TYPE Enable or disable maximum current alarm generation for this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.15 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoBreakerAlarmEnable OBJECT-TYPE Enable or disable breaker position alarms for this subfeed. | 1.3.6.1.4.1.318.1.1.22.3.2.1.16 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoTotalPower OBJECT-TYPE The total power being supplied by this subfeed. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.22.3.2.1.17 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedInfoKwhUsage OBJECT-TYPE The total energy consumed by the load equipment fed by this subfeed. This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate OID, and may be cleared using the isxModularDistSubFeedInfoKwhReset OID. Measured in tenths of kWh. | 1.3.6.1.4.1.318.1.1.22.3.2.1.18 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedInfoKwhReset OBJECT-TYPE Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSubFeedInfoKwhUsage OID. | 1.3.6.1.4.1.318.1.1.22.3.2.1.19 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| isxModularDistSubFeedInfoKwhResetDate OBJECT-TYPE The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000. | 1.3.6.1.4.1.318.1.1.22.3.2.1.20 | DisplayString | read-only | mandatory |
| isxModularDistSubFeedLoadingTableSize OBJECT-TYPE The number of entries in the isxModularDistSubFeedLoadingTable. | 1.3.6.1.4.1.318.1.1.22.3.3 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedLoadingTable OBJECT-TYPE Allows for getting subfeed phase loading information. | 1.3.6.1.4.1.318.1.1.22.3.4 | not-accessible | mandatory | |
| isxModularDistSubFeedLoadingEntry OBJECT-TYPE An entry containing data for an individual subfeed. | 1.3.6.1.4.1.318.1.1.22.3.4.1 | not-accessible | mandatory | |
| isxModularDistSubFeedLoadingSubIndex OBJECT-TYPE The index of an individual subfeed. | 1.3.6.1.4.1.318.1.1.22.3.4.1.1 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedLoadingPhaseIndex OBJECT-TYPE Description of each input phase entry in the table. | 1.3.6.1.4.1.318.1.1.22.3.4.1.2 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| isxModularDistSubFeedLoadingAlarmStatus OBJECT-TYPE This is a bit map representing the active alarms for this subfeed: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) b4 - Breaker is open (critical) If a bit is set, the corresponding alarm is active. | 1.3.6.1.4.1.318.1.1.22.3.4.1.3 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedLoadingCurrent OBJECT-TYPE The current flowing though this subfeed phase. Measured in tenths of amps. | 1.3.6.1.4.1.318.1.1.22.3.4.1.4 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedLoadingPercent OBJECT-TYPE The loading on this subfeed phase as a percentage of the subfeed's current rating. Expressed in tenths of percent. | 1.3.6.1.4.1.318.1.1.22.3.4.1.5 | INTEGER | read-only | mandatory |
| isxModularDistSubFeedLoadingPower OBJECT-TYPE The power being supplied by this subfeed phase. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.22.3.4.1.6 | INTEGER | read-only | mandatory |
| isxModularDistTotals OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.4 | |||
| isxModularDistSysVoltage OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.4.1 | |||
| isxModularDistSysOutputVoltageNominalLineToNeutral OBJECT-TYPE The nominal line-to-neutral voltage available at the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.1.1 | INTEGER | read-only | mandatory |
| isxModularDistSysOutputVoltageNominalLineToLine OBJECT-TYPE The nominal line-to-line voltage available at the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.1.2 | INTEGER | read-only | mandatory |
| isxModularDistSysOutputNominalFrequency OBJECT-TYPE The nominal system output frequency. Measured in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.22.4.1.3 | INTEGER | read-only | mandatory |
| isxModularDistSysOutputFrequency OBJECT-TYPE The system output frequency in tenths of Hertz. -1 if not available. | 1.3.6.1.4.1.318.1.1.22.4.1.4 | INTEGER | read-only | mandatory |
| isxModularDistSysOutputVoltageMonitoring OBJECT-TYPE Indicates whether or not output voltage alarm generation is present. | 1.3.6.1.4.1.318.1.1.22.4.1.5 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| isxModularDistSysOutputVoltageThresholdMin OBJECT-TYPE When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. This value is returned as a positive number which represents a negative percentage. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.1.6 | INTEGER | read-write | mandatory |
| isxModularDistSysOutputVoltageThresholdLow OBJECT-TYPE When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. This value is returned as a positive number which represents a negative percentage. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.1.7 | INTEGER | read-write | mandatory |
| isxModularDistSysOutputVoltageThresholdHigh OBJECT-TYPE When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.1.8 | INTEGER | read-write | mandatory |
| isxModularDistSysOutputVoltageThresholdMax OBJECT-TYPE When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.1.9 | INTEGER | read-write | mandatory |
| isxModularDistSysOutputVoltageAlarmMinEnable OBJECT-TYPE Enable or disable minimum voltage alarm generation for the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.1.10 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysOutputVoltageAlarmLowEnable OBJECT-TYPE Enable or disable low voltage alarm generation for the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.1.11 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysOutputVoltageAlarmHighEnable OBJECT-TYPE Enable or disable high voltage alarm generation for the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.1.12 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysOutputVoltageAlarmMaxEnable OBJECT-TYPE Enable or disable maximum voltage alarm generation for the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.1.13 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysOutputVoltageFrequencyTolerance OBJECT-TYPE The circuit panel output frequency tolerance in Hertz. When the system output frequency deviates from the nominal by more than this range, a critical alarm will be generated. | 1.3.6.1.4.1.318.1.1.22.4.1.14 | INTEGER {freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10), freqToleranceNotAvailable(11)} | read-write | mandatory |
| isxModularDistSysVoltageTable OBJECT-TYPE Allows for getting the system output voltage information. | 1.3.6.1.4.1.318.1.1.22.4.1.15 | not-accessible | mandatory | |
| isxModularDistSysVoltageEntry OBJECT-TYPE An entry containing data for an individual system output phase. | 1.3.6.1.4.1.318.1.1.22.4.1.15.1 | not-accessible | mandatory | |
| isxModularDistSysVoltagePhaseIndex OBJECT-TYPE Description of each phase entry in the table. | 1.3.6.1.4.1.318.1.1.22.4.1.15.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| isxModularDistSysVoltageAlarmStatus OBJECT-TYPE This is a bit map representing the active alarms for this output phase: b0 - Minimum voltage threshold exceeded (critical) b1 - Low voltage threshold exceeded (warning) b2 - High voltage threshold exceeded (warning) b3 - Maximum voltage threshold exceeded (critical) If a bit is set, the corresponding alarm is active. | 1.3.6.1.4.1.318.1.1.22.4.1.15.1.2 | INTEGER | read-only | mandatory |
| isxModularDistSysVoltageLtoN OBJECT-TYPE Line-to-neutral system output voltage available at the distribution panel. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.22.4.1.15.1.3 | INTEGER | read-only | mandatory |
| isxModularDistSysVoltageLtoL OBJECT-TYPE Line-to-line system output voltage available at the distribution panel. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.22.4.1.15.1.4 | INTEGER | read-only | mandatory |
| isxModularDistSysCurrent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.4.2 | |||
| isxModularDistSysCurrentRating OBJECT-TYPE The 100 percent current rating of the distribution panel. | 1.3.6.1.4.1.318.1.1.22.4.2.1 | INTEGER | read-only | mandatory |
| isxModularDistSysCurrentMonitoring OBJECT-TYPE Indicates whether or not total output current measurements and alarm generation are present. | 1.3.6.1.4.1.318.1.1.22.4.2.2 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| isxModularDistSysCurrentThresholdMin OBJECT-TYPE When total system current in any phase drops below this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.2.3 | INTEGER | read-write | mandatory |
| isxModularDistSysCurrentThresholdLow OBJECT-TYPE When total system current in any phase drops below this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.2.4 | INTEGER | read-write | mandatory |
| isxModularDistSysCurrentThresholdHigh OBJECT-TYPE When total system current in any phase exceeds this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.2.5 | INTEGER | read-write | mandatory |
| isxModularDistSysCurrentThresholdMax OBJECT-TYPE When total system current in any phase exceeds this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device. | 1.3.6.1.4.1.318.1.1.22.4.2.6 | INTEGER | read-write | mandatory |
| isxModularDistSysCurrentAlarmMinEnable OBJECT-TYPE Enable or disable minimum total output current alarm generation. | 1.3.6.1.4.1.318.1.1.22.4.2.7 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysCurrentAlarmLowEnable OBJECT-TYPE Enable or disable low total output current alarm generation. | 1.3.6.1.4.1.318.1.1.22.4.2.8 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysCurrentAlarmHighEnable OBJECT-TYPE Enable or disable high total output current alarm generation. | 1.3.6.1.4.1.318.1.1.22.4.2.9 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysCurrentAlarmMaxEnable OBJECT-TYPE Enable or disable maximum total output current alarm generation. | 1.3.6.1.4.1.318.1.1.22.4.2.10 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| isxModularDistSysCurrentTable OBJECT-TYPE Allows for getting the total system phase current information. | 1.3.6.1.4.1.318.1.1.22.4.2.11 | not-accessible | mandatory | |
| isxModularDistSysCurrentEntry OBJECT-TYPE An entry containing data for an individual system output phase. | 1.3.6.1.4.1.318.1.1.22.4.2.11.1 | not-accessible | mandatory | |
| isxModularDistSysCurrentPhaseIndex OBJECT-TYPE Description of each phase entry in the table. | 1.3.6.1.4.1.318.1.1.22.4.2.11.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| isxModularDistSysCurrentAlarmStatus OBJECT-TYPE This is a bit map representing the active alarms for this output phase: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) If a bit is set, the corresponding alarm is active. | 1.3.6.1.4.1.318.1.1.22.4.2.11.1.2 | INTEGER | read-only | mandatory |
| isxModularDistSysCurrentAmps OBJECT-TYPE The current flowing though this system output phase. Measured in tenths of amps. | 1.3.6.1.4.1.318.1.1.22.4.2.11.1.3 | INTEGER | read-only | mandatory |
| isxModularDistSysCurrentPercent OBJECT-TYPE The loading on this system output phase as a percentage of the panel current rating. Expressed in tenths of percent. | 1.3.6.1.4.1.318.1.1.22.4.2.11.1.4 | INTEGER | read-only | mandatory |
| isxModularDistSysPower OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.22.4.3 | |||
| isxModularDistSysPowerTotal OBJECT-TYPE The total system power being supplied. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.22.4.3.1 | INTEGER | read-only | mandatory |
| isxModularDistSysPowerKwhUsage OBJECT-TYPE The total system energy consumed by the load equipment. This is the total since the date specified in the isxModularDistSysOutputKwhResetDate OID, and may be cleared using the isxModularDistSysOutputKwhReset OID. Measured in tenths of kWh. | 1.3.6.1.4.1.318.1.1.22.4.3.2 | INTEGER | read-only | mandatory |
| isxModularDistSysPowerKwhReset OBJECT-TYPE Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSysPowerKwhUsage OID. | 1.3.6.1.4.1.318.1.1.22.4.3.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| isxModularDistSysPowerKwhResetDate OBJECT-TYPE The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000. | 1.3.6.1.4.1.318.1.1.22.4.3.4 | DisplayString | read-only | mandatory |
| isxModularDistSysPowerTable OBJECT-TYPE Allows for getting the total system phase power loading information. | 1.3.6.1.4.1.318.1.1.22.4.3.5 | not-accessible | mandatory | |
| isxModularDistSysPowerEntry OBJECT-TYPE An entry containing data for an individual system output phase. | 1.3.6.1.4.1.318.1.1.22.4.3.5.1 | not-accessible | mandatory | |
| isxModularDistSysPowerPhaseIndex OBJECT-TYPE Description of each phase entry in the table. | 1.3.6.1.4.1.318.1.1.22.4.3.5.1.1 | INTEGER {phase1(1), phase2(2), phase3(3)} | read-only | mandatory |
| isxModularDistSysPowerKw OBJECT-TYPE The power being supplied by this system output phase. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.22.4.3.5.1.2 | INTEGER | read-only | mandatory |
| isxModularDistSysPowerKwhPhaseUsage OBJECT-TYPE The energy consumed by the load equipment on this system output phase. This is the total since the date specified in the isxModularDistSysPowerKwhResetDate OID, and may be cleared using the isxModularDistSysPowerKwhReset OID. Measured in tenths of kWh. | 1.3.6.1.4.1.318.1.1.22.4.3.5.1.3 | INTEGER | read-only | mandatory |
| isxModularPdu OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.23 | |||
| isxModularPduIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.23.1 | |||
| isxModularPduIdentModelNumber OBJECT-TYPE A character string identifying the model number of the PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.23.1.1 | DisplayString | read-only | mandatory |
| isxModularPduIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the PDU. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.23.1.2 | DisplayString | read-only | mandatory |
| isxModularPduIdentDateOfManufacture OBJECT-TYPE The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.23.1.3 | DisplayString | read-only | mandatory |
| isxModularPduIdentMonitorCardSerialNumber OBJECT-TYPE A character string identifying the serial number of the PDU monitor card. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.23.1.4 | DisplayString | read-only | mandatory |
| isxModularPduIdentMonitorCardHardwareRev OBJECT-TYPE The hardware revision of the PDU monitor card. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.23.1.5 | DisplayString | read-only | mandatory |
| isxModularPduIdentMonitorCardFirmwareAppRev OBJECT-TYPE An ID string identifying the application firmware revision of the PDU monitor card. | 1.3.6.1.4.1.318.1.1.23.1.6 | DisplayString | read-only | mandatory |
| isxModularPduIdentMonitorCardFirmwareAppOSRev OBJECT-TYPE An ID string identifying the application operating system firmware revision of the PDU monitor card. | 1.3.6.1.4.1.318.1.1.23.1.7 | DisplayString | read-only | mandatory |
| isxModularPduDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.23.2 | |||
| isxModularPduDeviceTransformerPresent OBJECT-TYPE Indicates the type of transformer present in this PDU. | 1.3.6.1.4.1.318.1.1.23.2.1 | INTEGER {notPresent(1), isoXfmrPresent(2), autoXfmrPresent(3)} | read-only | mandatory |
| isxModularPduDeviceServiceType OBJECT-TYPE The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye). | 1.3.6.1.4.1.318.1.1.23.2.2 | INTEGER {threeWire(1), fourWire(2)} | read-only | mandatory |
| isxModularPduDeviceFansPresent OBJECT-TYPE Indicates whether or not cooling fans are installed in the PDU. | 1.3.6.1.4.1.318.1.1.23.2.3 | INTEGER {notPresent(1), present(2)} | read-only | mandatory |
| isxModularPduDeviceNominalMainInputVoltage OBJECT-TYPE The nominal main input voltage to the system. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. -1 if main input voltage is not being measured. | 1.3.6.1.4.1.318.1.1.23.2.4 | INTEGER | read-only | mandatory |
| isxModularPduStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.23.3 | |||
| isxModularPduAlarmStatus OBJECT-TYPE The overall status (worst case) of this PDU. | 1.3.6.1.4.1.318.1.1.23.3.1 | INTEGER {normal(1), warning(2), critical(3)} | read-only | mandatory |
| isxModularPduTransformerTempStatus OBJECT-TYPE Indicates if the PDU isolation transformer is over temperature. | 1.3.6.1.4.1.318.1.1.23.3.2 | INTEGER {normal(1), overtemp(2), noTransformerPresent(3), unknown(4)} | read-only | mandatory |
| isxModularPduFanStatus OBJECT-TYPE Indicates if one or more of the PDU's cooling fans have failed. | 1.3.6.1.4.1.318.1.1.23.3.3 | INTEGER {normal(1), failed(2), noCoolingFansPresent(3), unknown(4)} | read-only | mandatory |
| universalInputOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.25 | |||
| uioSensor OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.25.1 | |||
| uioSensorStatusTableSize OBJECT-TYPE The number of entries in the uioSensorStatusTable. | 1.3.6.1.4.1.318.1.1.25.1.1 | INTEGER | read-only | mandatory |
| uioSensorStatusTable OBJECT-TYPE Allows for getting sensor status information. | 1.3.6.1.4.1.318.1.1.25.1.2 | not-accessible | mandatory | |
| uioSensorStatusEntry OBJECT-TYPE The unit from which to get data. | 1.3.6.1.4.1.318.1.1.25.1.2.1 | not-accessible | mandatory | |
| uioSensorStatusPortID OBJECT-TYPE The ID of the port to which the sensor is attached. | 1.3.6.1.4.1.318.1.1.25.1.2.1.1 | INTEGER | read-only | mandatory |
| uioSensorStatusSensorID OBJECT-TYPE The ID of the sensor. | 1.3.6.1.4.1.318.1.1.25.1.2.1.2 | INTEGER | read-only | mandatory |
| uioSensorStatusSensorName OBJECT-TYPE The sensor name. | 1.3.6.1.4.1.318.1.1.25.1.2.1.3 | DisplayString | read-only | mandatory |
| uioSensorStatusSensorLocation OBJECT-TYPE The location of the sensor. | 1.3.6.1.4.1.318.1.1.25.1.2.1.4 | DisplayString | read-only | mandatory |
| uioSensorStatusTemperatureDegF OBJECT-TYPE The sensor's current temperature reading in degrees Fahrenheit. -1 indicates an invalid reading due to lost communications. | 1.3.6.1.4.1.318.1.1.25.1.2.1.5 | INTEGER | read-only | mandatory |
| uioSensorStatusTemperatureDegC OBJECT-TYPE The sensor's current temperature reading in degrees Celsius. -1 indicates an invalid reading due to lost communications. | 1.3.6.1.4.1.318.1.1.25.1.2.1.6 | INTEGER | read-only | mandatory |
| uioSensorStatusHumidity OBJECT-TYPE The sensor's current humidity reading in percent relative humidity. -1 indicates an invalid reading due to either a sensor that doesn't read humidity or lost communications. | 1.3.6.1.4.1.318.1.1.25.1.2.1.7 | INTEGER | read-only | mandatory |
| uioSensorStatusViolationStatus OBJECT-TYPE The violation status of the sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Short-term increasing temperature rate exceeded (Not used). 6 0x0020 Short-term decreasing temperature rate exceeded (Not used). 7 0x0040 Long-term increasing temperature rate exceeded (Not used). 8 0x0080 Long-term decreasing temperature rate exceeded (Not used). 9 0x0100 Maximum humidity exceeded. 10 0x0200 High humidity exceeded. 11 0x0400 Low humidity exceeded. 12 0x0800 Minimum humidity exceeded. | 1.3.6.1.4.1.318.1.1.25.1.2.1.8 | INTEGER | read-only | mandatory |
| uioSensorStatusAlarmStatus OBJECT-TYPE The alarm status of the sensor. | 1.3.6.1.4.1.318.1.1.25.1.2.1.9 | INTEGER {uioNormal(1), uioWarning(2), uioCritical(3), sensorStatusNotApplicable(4)} | read-only | mandatory |
| uioSensorStatusCommStatus OBJECT-TYPE The communications status of the sensor. | 1.3.6.1.4.1.318.1.1.25.1.2.1.10 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| uioSensorConfigTableSize OBJECT-TYPE The number of entries in the uioSensorConfigTable. | 1.3.6.1.4.1.318.1.1.25.1.3 | INTEGER | read-only | mandatory |
| uioSensorConfigTable OBJECT-TYPE Allows for configuring the sensor. | 1.3.6.1.4.1.318.1.1.25.1.4 | not-accessible | mandatory | |
| uioSensorConfigEntry OBJECT-TYPE The sensor from which to get configuration. | 1.3.6.1.4.1.318.1.1.25.1.4.1 | not-accessible | mandatory | |
| uioSensorConfigPortID OBJECT-TYPE The ID of the port to which the sensor is attached. | 1.3.6.1.4.1.318.1.1.25.1.4.1.1 | INTEGER | read-only | mandatory |
| uioSensorConfigSensorID OBJECT-TYPE The ID of the sensor. | 1.3.6.1.4.1.318.1.1.25.1.4.1.2 | INTEGER | read-only | mandatory |
| uioSensorConfigSensorName OBJECT-TYPE The sensor name. | 1.3.6.1.4.1.318.1.1.25.1.4.1.3 | DisplayString | read-write | mandatory |
| uioSensorConfigSensorLocation OBJECT-TYPE The location of the sensor. | 1.3.6.1.4.1.318.1.1.25.1.4.1.4 | DisplayString | read-write | mandatory |
| uioSensorConfigMinTemperatureThreshold OBJECT-TYPE The minimum (critical) temperature alarm threshold for the probe in degrees C. Must be lower than the low threshold to ensure proper sensor alarm behavior. | 1.3.6.1.4.1.318.1.1.25.1.4.1.5 | INTEGER | read-write | mandatory |
| uioSensorConfigLowTemperatureThreshold OBJECT-TYPE The low (warning) temperature alarm threshold for the probe in degrees C. Must be higher than the minimum threshold and lower than the high threshold to ensure proper sensor alarm behavior. | 1.3.6.1.4.1.318.1.1.25.1.4.1.6 | INTEGER | read-write | mandatory |
| uioSensorConfigHighTemperatureThreshold OBJECT-TYPE The high (warning) temperature alarm threshold for the probe in degrees C. Must be lower than the maximum threshold and higher than the low threshold to ensure proper sensor alarm behavior. | 1.3.6.1.4.1.318.1.1.25.1.4.1.7 | INTEGER | read-write | mandatory |
| uioSensorConfigMaxTemperatureThreshold OBJECT-TYPE The maximum (critical) temperature alarm threshold for the probe in degrees C. Must be higher than the high threshold to ensure proper sensor alarm behavior. | 1.3.6.1.4.1.318.1.1.25.1.4.1.8 | INTEGER | read-write | mandatory |
| uioSensorConfigTemperatureHysteresis OBJECT-TYPE The number of degrees C beyond the temperature thresholds at which an active temperature alarm will be cleared. This value applies to all temperature thresholds. | 1.3.6.1.4.1.318.1.1.25.1.4.1.9 | INTEGER | read-write | mandatory |
| uioSensorConfigMinTemperatureEnable OBJECT-TYPE The minimum temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.10 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigLowTemperatureEnable OBJECT-TYPE The low temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.11 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigHighTemperatureEnable OBJECT-TYPE The high temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.12 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigMaxTemperatureEnable OBJECT-TYPE The maximum temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.13 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigMinHumidityThreshold OBJECT-TYPE The minimum (critical) humidity alarm threshold for the probe in percent relative humidity. Must be lower than the low threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity. | 1.3.6.1.4.1.318.1.1.25.1.4.1.14 | INTEGER | read-write | mandatory |
| uioSensorConfigLowHumidityThreshold OBJECT-TYPE The low (warning) humidity alarm threshold for the probe in percent relative humidity. Must be higher than the minimum threshold and lower than the high threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity. | 1.3.6.1.4.1.318.1.1.25.1.4.1.15 | INTEGER | read-write | mandatory |
| uioSensorConfigHighHumidityThreshold OBJECT-TYPE The high (warning) humidity alarm threshold for the probe in percent relative humidity. Must be lower than the maximum threshold and higher than the low threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity. | 1.3.6.1.4.1.318.1.1.25.1.4.1.16 | INTEGER | read-write | mandatory |
| uioSensorConfigMaxHumidityThreshold OBJECT-TYPE The maximum (critical) humidity alarm threshold for the probe in percent relative humidity. Must be higher than the high threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity. | 1.3.6.1.4.1.318.1.1.25.1.4.1.17 | INTEGER | read-write | mandatory |
| uioSensorConfigHumidityHysteresis OBJECT-TYPE The number of percent relative humidity beyond the humidity thresholds at which an active humidity alarm will be cleared. This value applies to all humidity thresholds. -1 if the sensor doesn't read humidity. | 1.3.6.1.4.1.318.1.1.25.1.4.1.18 | INTEGER | read-write | mandatory |
| uioSensorConfigMinHumidityEnable OBJECT-TYPE The minimum humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.19 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigLowHumidityEnable OBJECT-TYPE The low humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.20 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigHighHumidityEnable OBJECT-TYPE The high humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.21 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioSensorConfigMaxHumidityEnable OBJECT-TYPE The maximum humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled | 1.3.6.1.4.1.318.1.1.25.1.4.1.22 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| uioInputContact OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.25.2 | |||
| uioInputContactStatusTableSize OBJECT-TYPE The number of entries in the uioInputContactStatusTable. | 1.3.6.1.4.1.318.1.1.25.2.1 | INTEGER | read-only | mandatory |
| uioInputContactStatusTable OBJECT-TYPE Allows for getting input contact status information. | 1.3.6.1.4.1.318.1.1.25.2.2 | not-accessible | mandatory | |
| uioInputContactStatusEntry OBJECT-TYPE The input contact from which to get data. | 1.3.6.1.4.1.318.1.1.25.2.2.1 | not-accessible | mandatory | |
| uioInputContactStatusPortID OBJECT-TYPE The ID of the port to which the input contact is attached. | 1.3.6.1.4.1.318.1.1.25.2.2.1.1 | INTEGER | read-only | mandatory |
| uioInputContactStatusContactID OBJECT-TYPE The ID of the input contact on the module. | 1.3.6.1.4.1.318.1.1.25.2.2.1.2 | INTEGER | read-only | mandatory |
| uioInputContactStatusContactName OBJECT-TYPE The input contact name. | 1.3.6.1.4.1.318.1.1.25.2.2.1.3 | DisplayString | read-only | mandatory |
| uioInputContactStatusContactLocation OBJECT-TYPE The location of the input contact. | 1.3.6.1.4.1.318.1.1.25.2.2.1.4 | DisplayString | read-only | mandatory |
| uioInputContactStatusCurrentState OBJECT-TYPE The current state of the input contact. | 1.3.6.1.4.1.318.1.1.25.2.2.1.5 | INTEGER {uioInputClosed(1), uioInputOpen(2), uioInputDisabled(3), inputStateNotApplicable(4)} | read-only | mandatory |
| uioInputContactStatusAlarmStatus OBJECT-TYPE The alarm status of the input contact. | 1.3.6.1.4.1.318.1.1.25.2.2.1.6 | INTEGER {uioNormal(1), uioWarning(2), uioCritical(3), inputStatusNotApplicable(4)} | read-only | mandatory |
| uioInputContactStatusCommStatus OBJECT-TYPE The communications status of the input contact. | 1.3.6.1.4.1.318.1.1.25.2.2.1.7 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| uioInputContactConfigTableSize OBJECT-TYPE The number of entries in the uioInputContactConfigTable. | 1.3.6.1.4.1.318.1.1.25.2.3 | INTEGER | read-only | mandatory |
| uioInputContactConfigTable OBJECT-TYPE Allows for configuring the input contacts. | 1.3.6.1.4.1.318.1.1.25.2.4 | not-accessible | mandatory | |
| uioInputContactConfigEntry OBJECT-TYPE The input contact from which to get configuration. | 1.3.6.1.4.1.318.1.1.25.2.4.1 | not-accessible | mandatory | |
| uioInputContactConfigPortID OBJECT-TYPE The ID of the port to which the input contact is attached. | 1.3.6.1.4.1.318.1.1.25.2.4.1.1 | INTEGER | read-only | mandatory |
| uioInputContactConfigContactID OBJECT-TYPE The ID of the input contact on the module. | 1.3.6.1.4.1.318.1.1.25.2.4.1.2 | INTEGER | read-only | mandatory |
| uioInputContactConfigContactName OBJECT-TYPE The input contact name. | 1.3.6.1.4.1.318.1.1.25.2.4.1.3 | DisplayString | read-write | mandatory |
| uioInputContactConfigContactLocation OBJECT-TYPE The location of the input contact. | 1.3.6.1.4.1.318.1.1.25.2.4.1.4 | DisplayString | read-write | mandatory |
| uioInputContactConfigEnable OBJECT-TYPE Enable or disable this input contact. 1 - disabled 2 - enabled | 1.3.6.1.4.1.318.1.1.25.2.4.1.5 | INTEGER {uioInputContactDisabled(1), uioInputContactEnabled(2)} | read-write | mandatory |
| uioInputContactConfigNormalState OBJECT-TYPE The normal (non-alarm) state of the input contact. 1 - normally open 2 - normally closed | 1.3.6.1.4.1.318.1.1.25.2.4.1.6 | INTEGER {uioInputNormallyOpen(1), uioInputNormallyClosed(2)} | read-write | mandatory |
| uioInputContactConfigSeverity OBJECT-TYPE The severity of the alarm that this input contact will generate in the abnormal state. 1 - critical severity 2 - warning severity | 1.3.6.1.4.1.318.1.1.25.2.4.1.7 | INTEGER {uioInputCriticalSeverity(1), uioInputWarningSeverity(2)} | read-write | mandatory |
| uioOutputRelay OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.25.3 | |||
| uioOutputRelayStatusTableSize OBJECT-TYPE The number of entries in the uioOutputRelayStatusTable. | 1.3.6.1.4.1.318.1.1.25.3.1 | INTEGER | read-only | mandatory |
| uioOutputRelayStatusTable OBJECT-TYPE Allows for getting output relay status information. | 1.3.6.1.4.1.318.1.1.25.3.2 | not-accessible | mandatory | |
| uioOutputRelayStatusEntry OBJECT-TYPE The unit from which to get data. | 1.3.6.1.4.1.318.1.1.25.3.2.1 | not-accessible | mandatory | |
| uioOutputRelayStatusPortID OBJECT-TYPE The ID of the port to which the output relay is attached. | 1.3.6.1.4.1.318.1.1.25.3.2.1.1 | INTEGER | read-only | mandatory |
| uioOutputRelayStatusRelayID OBJECT-TYPE The ID of the output relay on the module. | 1.3.6.1.4.1.318.1.1.25.3.2.1.2 | INTEGER | read-only | mandatory |
| uioOutputRelayStatusRelayName OBJECT-TYPE The output relay name. | 1.3.6.1.4.1.318.1.1.25.3.2.1.3 | DisplayString | read-only | mandatory |
| uioOutputRelayStatusRelayLocation OBJECT-TYPE The location of the output relay. | 1.3.6.1.4.1.318.1.1.25.3.2.1.4 | DisplayString | read-only | mandatory |
| uioOutputRelayStatusCurrentState OBJECT-TYPE The current state of the output relay. | 1.3.6.1.4.1.318.1.1.25.3.2.1.5 | INTEGER {uioOutputClosed(1), uioOutputOpen(2), outputStateNotApplicable(3)} | read-only | mandatory |
| uioOutputRelayStatusAlarmStatus OBJECT-TYPE The alarm status of the output relay. | 1.3.6.1.4.1.318.1.1.25.3.2.1.6 | INTEGER {uioNormal(1), uioWarning(2), uioCritical(3), inputStatusNotApplicable(4)} | read-only | mandatory |
| uioOutputRelayStatusCommStatus OBJECT-TYPE The communications status of the output relay. | 1.3.6.1.4.1.318.1.1.25.3.2.1.7 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| uioOutputRelayConfigTableSize OBJECT-TYPE The number of entries in the uioOutputRelayConfigTable. | 1.3.6.1.4.1.318.1.1.25.3.3 | INTEGER | read-only | mandatory |
| uioOutputRelayConfigTable OBJECT-TYPE Allows for configuring the output relay. | 1.3.6.1.4.1.318.1.1.25.3.4 | not-accessible | mandatory | |
| uioOutputRelayConfigEntry OBJECT-TYPE The unit from which to get configuration. | 1.3.6.1.4.1.318.1.1.25.3.4.1 | not-accessible | mandatory | |
| uioOutputRelayConfigPortID OBJECT-TYPE The ID of the port to which the output relay is attached. | 1.3.6.1.4.1.318.1.1.25.3.4.1.1 | INTEGER | read-only | mandatory |
| uioOutputRelayConfigRelayID OBJECT-TYPE The ID of the output relay on the module. | 1.3.6.1.4.1.318.1.1.25.3.4.1.2 | INTEGER | read-only | mandatory |
| uioOutputRelayConfigRelayName OBJECT-TYPE The output relay name. | 1.3.6.1.4.1.318.1.1.25.3.4.1.3 | DisplayString | read-write | mandatory |
| uioOutputRelayConfigRelayLocation OBJECT-TYPE The location of the output relay. | 1.3.6.1.4.1.318.1.1.25.3.4.1.4 | DisplayString | read-write | mandatory |
| uioOutputRelayConfigNormalState OBJECT-TYPE The normal state of the output relay. 1 - normally open 2 - normally closed | 1.3.6.1.4.1.318.1.1.25.3.4.1.5 | INTEGER {uioOutputNormallyOpen(1), uioOutputNormallyClosed(2)} | read-write | mandatory |
| uioOutputRelayConfigControlState OBJECT-TYPE Close or open the output relay for testing purposes. Always returns 1 when read. 1 - close output relay 2 - open output relay | 1.3.6.1.4.1.318.1.1.25.3.4.1.6 | INTEGER {uioOutputClose(1), uioOutputOpen(2)} | read-write | mandatory |
| uioOutputRelayConfigDelay OBJECT-TYPE The time a selected alarm condition must exist before the output relay is activated. Valid values are whole seconds from 0 to 65535. | 1.3.6.1.4.1.318.1.1.25.3.4.1.7 | TimeTicks | read-write | mandatory |
| uioOutputRelayConfigHold OBJECT-TYPE The minimum time the output relay remains activated after the alarm occurs. Valid values are whole seconds from 0 to 65535. | 1.3.6.1.4.1.318.1.1.25.3.4.1.8 | TimeTicks | read-write | mandatory |
| rPDU2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26 | |||
| rPDU2IdentTableSize OBJECT-TYPE The total number of Rack PDUs | 1.3.6.1.4.1.318.1.1.26.1 | INTEGER | read-only | mandatory |
| rPDU2IdentTable OBJECT-TYPE A table of Rack PDU identification data | 1.3.6.1.4.1.318.1.1.26.2 | not-accessible | mandatory | |
| rPDU2IdentEntry OBJECT-TYPE Identification data from Rack PDU being queried | 1.3.6.1.4.1.318.1.1.26.2.1 | not-accessible | mandatory | |
| rPDU2IdentIndex OBJECT-TYPE The index to the Rack PDU identification table entry | 1.3.6.1.4.1.318.1.1.26.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2IdentModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2IdentName OBJECT-TYPE A user-defined string identifying the Rack PDU | 1.3.6.1.4.1.318.1.1.26.2.1.3 | DisplayString | read-only | mandatory |
| rPDU2IdentLocation OBJECT-TYPE A user-defined string identifying the location of the Rack PDU | 1.3.6.1.4.1.318.1.1.26.2.1.4 | DisplayString | read-only | mandatory |
| rPDU2IdentHardwareRev OBJECT-TYPE The Rack PDU hardware version | 1.3.6.1.4.1.318.1.1.26.2.1.5 | DisplayString | read-only | mandatory |
| rPDU2IdentFirmwareRev OBJECT-TYPE The Rack PDU firmware version | 1.3.6.1.4.1.318.1.1.26.2.1.6 | DisplayString | read-only | mandatory |
| rPDU2IdentDateOfManufacture OBJECT-TYPE The date the Rack PDU was manufactured in mm/dd/yyyy format | 1.3.6.1.4.1.318.1.1.26.2.1.7 | DisplayString | read-only | mandatory |
| rPDU2IdentModelNumber OBJECT-TYPE The Rack PDU model number | 1.3.6.1.4.1.318.1.1.26.2.1.8 | DisplayString | read-only | mandatory |
| rPDU2IdentSerialNumber OBJECT-TYPE The Rack PDU serial number | 1.3.6.1.4.1.318.1.1.26.2.1.9 | DisplayString | read-only | mandatory |
| rPDU2IdentContact OBJECT-TYPE A user-defined string identifying the person to contact regarding the Rack PDU | 1.3.6.1.4.1.318.1.1.26.2.1.10 | DisplayString | read-only | mandatory |
| rPDU2IdentBootMonitorRev OBJECT-TYPE The Rack PDU Boot Monitor version | 1.3.6.1.4.1.318.1.1.26.2.1.11 | DisplayString | read-only | mandatory |
| rPDU2IdentLongDescription OBJECT-TYPE The Rack PDU Long Description name | 1.3.6.1.4.1.318.1.1.26.2.1.12 | DisplayString | read-only | mandatory |
| rPDU2IdentNMCSerialNumber OBJECT-TYPE The Rack PDU Network Management Card (NMC) serial number | 1.3.6.1.4.1.318.1.1.26.2.1.13 | DisplayString | read-only | mandatory |
| rPDU2IndentAppBuildDate OBJECT-TYPE The Rack PDU Application build date | 1.3.6.1.4.1.318.1.1.26.2.1.14 | DisplayString | read-only | mandatory |
| rPDU2IndentAOSBuildDate OBJECT-TYPE The Rack PDU AOS build date | 1.3.6.1.4.1.318.1.1.26.2.1.15 | DisplayString | read-only | mandatory |
| rPDU2IndentBootMonBuildDate OBJECT-TYPE The Rack PDU Boot Monitor build date | 1.3.6.1.4.1.318.1.1.26.2.1.16 | DisplayString | read-only | mandatory |
| rPDU2DeviceTableSize OBJECT-TYPE The total number of Rack PDUs | 1.3.6.1.4.1.318.1.1.26.3 | INTEGER | read-only | mandatory |
| rPDU2Device OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.4 | |||
| rPDU2DeviceConfigTable OBJECT-TYPE A table of Rack PDU configuration data | 1.3.6.1.4.1.318.1.1.26.4.1 | not-accessible | mandatory | |
| rPDU2DeviceConfigEntry OBJECT-TYPE Configuration data from Rack PDU being queried | 1.3.6.1.4.1.318.1.1.26.4.1.1 | not-accessible | mandatory | |
| rPDU2DeviceConfigIndex OBJECT-TYPE The index to the Rack PDU table entry | 1.3.6.1.4.1.318.1.1.26.4.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2DeviceConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.4.1.1.2 | INTEGER | read-write | mandatory |
| rPDU2DeviceConfigName OBJECT-TYPE A user-defined string identifying the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.1.1.3 | DisplayString | read-write | mandatory |
| rPDU2DeviceConfigLocation OBJECT-TYPE A user-defined string identifying the location of the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.1.1.4 | DisplayString | read-write | mandatory |
| rPDU2DeviceConfigDisplayOrientation OBJECT-TYPE Indicates the intended physical orientation of the display. displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation | 1.3.6.1.4.1.318.1.1.26.4.1.1.5 | INTEGER {displayNormal(1), displayReverse(2)} | read-write | mandatory |
| rPDU2DeviceConfigColdstartDelay OBJECT-TYPE The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes). | 1.3.6.1.4.1.318.1.1.26.4.1.1.6 | INTEGER | read-write | mandatory |
| rPDU2DeviceConfigLowLoadPowerThreshold OBJECT-TYPE User-defined low power draw alarm threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.1.1.7 | INTEGER | read-write | mandatory |
| rPDU2DeviceConfigNearOverloadPowerThreshold OBJECT-TYPE User-defined near power overload threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.1.1.8 | INTEGER | read-write | mandatory |
| rPDU2DeviceConfigOverloadPowerThreshold OBJECT-TYPE User-defined power overload threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.1.1.9 | INTEGER | read-write | mandatory |
| rPDU2DeviceConfigDevicePeakPowerReset OBJECT-TYPE Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of not supported (3). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.318.1.1.26.4.1.1.10 | INTEGER {noOperation(1), reset(2), notSupported(3)} | read-write | mandatory |
| rPDU2DeviceConfigDeviceEnergyReset OBJECT-TYPE Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.318.1.1.26.4.1.1.11 | INTEGER {noOperation(1), reset(2), notSupported(3)} | read-write | mandatory |
| rPDU2DeviceConfigOutletsEnergyReset OBJECT-TYPE Setting this OID to reset (2) will cause the all outlet energy meter values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.318.1.1.26.4.1.1.12 | INTEGER {noOperation(1), reset(2), notSupported(3)} | read-write | mandatory |
| rPDU2DeviceConfigOutletsPeakLoadReset OBJECT-TYPE Setting this OID to reset (2) will cause the all outlet peak load values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.318.1.1.26.4.1.1.13 | INTEGER {noOperation(1), reset(2), notSupported(3)} | read-write | mandatory |
| rPDU2DeviceConfigContact OBJECT-TYPE A user-defined string identifying the person to contact regarding the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.1.1.14 | DisplayString | read-write | mandatory |
| rPDU2DevicePropertiesTable OBJECT-TYPE A table of Rack PDU properties | 1.3.6.1.4.1.318.1.1.26.4.2 | not-accessible | mandatory | |
| rPDU2DevicePropertiesEntry OBJECT-TYPE Properties of the Rack PDU being queried | 1.3.6.1.4.1.318.1.1.26.4.2.1 | not-accessible | mandatory | |
| rPDU2DevicePropertiesIndex OBJECT-TYPE The index to the Rack PDU properties table entry | 1.3.6.1.4.1.318.1.1.26.4.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.4.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesName OBJECT-TYPE A user-defined string identifying the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.3 | DisplayString | read-only | mandatory |
| rPDU2DevicePropertiesNumOutlets OBJECT-TYPE The number of outlets on the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.4 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesNumSwitchedOutlets OBJECT-TYPE The number of switched outlets on the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.5 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesNumMeteredOutlets OBJECT-TYPE The number of metered outlets on the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.6 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesNumPhases OBJECT-TYPE The number of phases present in the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.7 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesNumMeteredBanks OBJECT-TYPE The number of metered banks present in the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.8 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesMaxCurrentRating OBJECT-TYPE The maximum current rating, measured in Amps, for the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.9 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesOrientation OBJECT-TYPE Rack PDU orientation | 1.3.6.1.4.1.318.1.1.26.4.2.1.10 | INTEGER {horizontal(1), vertical(2), verticalISXv2(3), verticalISXv3(4)} | read-only | mandatory |
| rPDU2DevicePropertiesOutletLayout OBJECT-TYPE Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... or for single phase SKUs, all outlets 1-N seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces for AP88XX SKUs. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available. seqPhToNPhToPhPhToN(10) indicates outlet layout as follows: Group 1:1-N, Group 2:1-2, Group 3:2-N. | 1.3.6.1.4.1.318.1.1.26.4.2.1.11 | INTEGER {seqPhaseToNeutral(1), seqPhaseToPhase(2), seqPhToNeu21PhToPh(3), seqPhToPhGrouped(4), seqPhToNGrouped(5), seqPToN1516PToPGrouped(6), seqPhToPh2xGrouped(7), seqPhToN2xGrouped(8), seqNotApplicable(9), seqPhToNPhToPhPhToN(10)} | read-only | mandatory |
| rPDU2DevicePropertiesMaxPhaseCurrentRating OBJECT-TYPE The maximum current rating, measured in Amps, for the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.12 | INTEGER | read-only | mandatory |
| rPDU2DevicePropertiesDevicePowerRating OBJECT-TYPE The maximum power rating, measured in Watts, for the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.2.1.13 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusTable OBJECT-TYPE A table of Rack PDU status information | 1.3.6.1.4.1.318.1.1.26.4.3 | not-accessible | mandatory | |
| rPDU2DeviceStatusEntry OBJECT-TYPE Status information from the Rack PDU being queried | 1.3.6.1.4.1.318.1.1.26.4.3.1 | not-accessible | mandatory | |
| rPDU2DeviceStatusIndex OBJECT-TYPE The index to the Rack PDU status table entry | 1.3.6.1.4.1.318.1.1.26.4.3.1.1 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.4.3.1.2 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusName OBJECT-TYPE A user-defined string identifying the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.3.1.3 | DisplayString | read-only | mandatory |
| rPDU2DeviceStatusLoadState OBJECT-TYPE Indicates the present load status of the Rack PDU. Models that do not support this feature will respond to this OID with a value of notsupported (5). | 1.3.6.1.4.1.318.1.1.26.4.3.1.4 | INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4), notsupported(5)} | read-only | mandatory |
| rPDU2DeviceStatusPower OBJECT-TYPE The power consumption of the Rack PDU load in hundredths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.3.1.5 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusPeakPower OBJECT-TYPE The peak power consumption of the Rack PDU load in hundredths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.3.1.6 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusPeakPowerTimestamp OBJECT-TYPE Indicates the date and time that peak power consumption occurred. Models that do not support this feature will respond to this OID with string 'notsupported'. | 1.3.6.1.4.1.318.1.1.26.4.3.1.7 | DisplayString | read-only | mandatory |
| rPDU2DeviceStatusPeakPowerStartTime OBJECT-TYPE Indicates the date and time of the last device peak power reset. Models that do not support this feature will respond to this OID with string 'notsupported'. | 1.3.6.1.4.1.318.1.1.26.4.3.1.8 | DisplayString | read-only | mandatory |
| rPDU2DeviceStatusEnergy OBJECT-TYPE A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.3.1.9 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusEnergyStartTime OBJECT-TYPE Indicates the date and time of the last device energy meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. | 1.3.6.1.4.1.318.1.1.26.4.3.1.10 | DisplayString | read-only | mandatory |
| rPDU2DeviceStatusCommandPending OBJECT-TYPE Indicates whether or not the device is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cycled to clear this condition. | 1.3.6.1.4.1.318.1.1.26.4.3.1.11 | INTEGER {commandPending(1), noCommandPending(2), commandPendingUnknown(3)} | read-only | mandatory |
| rPDU2DeviceStatusPowerSupplyAlarm OBJECT-TYPE Indicates a power supply alarm is active when value equals alarm (2) | 1.3.6.1.4.1.318.1.1.26.4.3.1.12 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| rPDU2DeviceStatusPowerSupply1Status OBJECT-TYPE Indicates whether or not an alarm is active in Power Supply 1 | 1.3.6.1.4.1.318.1.1.26.4.3.1.13 | INTEGER {normal(1), alarm(2), notInstalled(3)} | read-only | mandatory |
| rPDU2DeviceStatusPowerSupply2Status OBJECT-TYPE Indicates whether or not an alarm is active in Power Supply 2 | 1.3.6.1.4.1.318.1.1.26.4.3.1.14 | INTEGER {normal(1), alarm(2), notInstalled(3)} | read-only | mandatory |
| rPDU2DeviceStatusOutletsEnergyStartTime OBJECT-TYPE Indicates the date and time of the last outlets energy meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. | 1.3.6.1.4.1.318.1.1.26.4.3.1.15 | DisplayString | read-only | mandatory |
| rPDU2DeviceStatusApparentPower OBJECT-TYPE The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA). Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.3.1.16 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusPowerFactor OBJECT-TYPE The power factor of the Rack PDU load in hundredths. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.4.3.1.17 | INTEGER | read-only | mandatory |
| rPDU2DeviceStatusNPSType OBJECT-TYPE The device NPS status: notNPS (1) indicates the Rack PDU is not in an NPS group. host (2) indicates the Rack PDU has been designated as a host in an NPS group. Only one Rack PDU in an NPS group is allowed to be the host. guest (3) indicates the Rack PDU has been designated as a guest in an NPS group. | 1.3.6.1.4.1.318.1.1.26.4.3.1.18 | INTEGER {notNPS(1), host(2), guest(3)} | read-only | mandatory |
| rPDU2DeviceControlTable OBJECT-TYPE A table of Rack PDU control data | 1.3.6.1.4.1.318.1.1.26.4.4 | not-accessible | mandatory | |
| rPDU2DeviceControlEntry OBJECT-TYPE Control data from Rack PDU being queried | 1.3.6.1.4.1.318.1.1.26.4.4.1 | not-accessible | mandatory | |
| rPDU2DeviceControlIndex OBJECT-TYPE The index to the Rack PDU control table entry | 1.3.6.1.4.1.318.1.1.26.4.4.1.1 | INTEGER | read-only | mandatory |
| rPDU2DeviceControlModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.4.4.1.2 | INTEGER | read-only | mandatory |
| rPDU2DeviceControlName OBJECT-TYPE A user-defined string identifying the Rack PDU | 1.3.6.1.4.1.318.1.1.26.4.4.1.3 | DisplayString | read-only | mandatory |
| rPDU2DeviceControlCommand OBJECT-TYPE Setting this OID to immediateAllOn (1) will turn all outlets on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime OID value. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will cause an immediateAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateAllOn command. Setting this OID to delayedAllReboot (5) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to noCommandAll (6) will have no effect. Setting this OID to delayedAllOff (7) will turn all outlets off as defined by each outlet's rPDU2OutletSwitchedConfigPowerOffTime OID value. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be cancelled. Getting this OID will return the noCommandAll (6) value. | 1.3.6.1.4.1.318.1.1.26.4.4.1.4 | INTEGER {immediateAllOn(1), delayedAllOn(2), immediateAllOff(3), immediateAllReboot(4), delayedAllReboot(5), noCommandAll(6), delayedAllOff(7), cancelAllPendingCommands(8)} | read-write | mandatory |
| rPDU2PhaseTableSize OBJECT-TYPE The number of connected Rack PDU phases | 1.3.6.1.4.1.318.1.1.26.5 | INTEGER | read-only | mandatory |
| rPDU2Phase OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.6 | |||
| rPDU2PhaseConfigTable OBJECT-TYPE A table of Rack PDU phase configuration data | 1.3.6.1.4.1.318.1.1.26.6.1 | not-accessible | mandatory | |
| rPDU2PhaseConfigEntry OBJECT-TYPE Configuration data from currently queried Rack PDU phase | 1.3.6.1.4.1.318.1.1.26.6.1.1 | not-accessible | mandatory | |
| rPDU2PhaseConfigIndex OBJECT-TYPE The index to the Rack PDU phase configuration table entry | 1.3.6.1.4.1.318.1.1.26.6.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2PhaseConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.6.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2PhaseConfigNumber OBJECT-TYPE The numeric phase ID | 1.3.6.1.4.1.318.1.1.26.6.1.1.3 | INTEGER | read-only | mandatory |
| rPDU2PhaseConfigOverloadRestriction OBJECT-TYPE This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigOverloadThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.318.1.1.26.6.1.1.4 | INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3), notSupported(4)} | read-write | mandatory |
| rPDU2PhaseConfigLowLoadCurrentThreshold OBJECT-TYPE User-defined low load phase current threshold in Amps | 1.3.6.1.4.1.318.1.1.26.6.1.1.5 | INTEGER | read-write | mandatory |
| rPDU2PhaseConfigNearOverloadCurrentThreshold OBJECT-TYPE User-defined near phase overload warning threshold in Amps | 1.3.6.1.4.1.318.1.1.26.6.1.1.6 | INTEGER | read-write | mandatory |
| rPDU2PhaseConfigOverloadCurrentThreshold OBJECT-TYPE User-defined phase overload current threshold in Amps | 1.3.6.1.4.1.318.1.1.26.6.1.1.7 | INTEGER | read-write | mandatory |
| rPDU2PhaseConfigPhasePeakCurrentReset OBJECT-TYPE Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.26.6.1.1.8 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| rPDU2PhasePropertiesTable OBJECT-TYPE A table of Rack PDU phase properties | 1.3.6.1.4.1.318.1.1.26.6.2 | not-accessible | mandatory | |
| rPDU2PhasePropertiesEntry OBJECT-TYPE Properties of the currently queried Rack PDU phase | 1.3.6.1.4.1.318.1.1.26.6.2.1 | not-accessible | mandatory | |
| rPDU2PhasePropertiesIndex OBJECT-TYPE The index to the Rack PDU phase properties table entry | 1.3.6.1.4.1.318.1.1.26.6.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2PhasePropertiesModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.6.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2PhasePropertiesNumber OBJECT-TYPE The numeric phase ID | 1.3.6.1.4.1.318.1.1.26.6.2.1.3 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusTable OBJECT-TYPE A table of Rack PDU phase status data | 1.3.6.1.4.1.318.1.1.26.6.3 | not-accessible | mandatory | |
| rPDU2PhaseStatusEntry OBJECT-TYPE Status data from currently queried Rack PDU phase | 1.3.6.1.4.1.318.1.1.26.6.3.1 | not-accessible | mandatory | |
| rPDU2PhaseStatusIndex OBJECT-TYPE The index to the Rack PDU phase status table entry | 1.3.6.1.4.1.318.1.1.26.6.3.1.1 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.6.3.1.2 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusNumber OBJECT-TYPE The numeric phase ID | 1.3.6.1.4.1.318.1.1.26.6.3.1.3 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusLoadState OBJECT-TYPE Indicates the present load status of the Rack PDU phase being queried | 1.3.6.1.4.1.318.1.1.26.6.3.1.4 | INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4)} | read-only | mandatory |
| rPDU2PhaseStatusCurrent OBJECT-TYPE Indicates the current draw, in tenths of Amps, of the load on the Rack PDU phase being queried | 1.3.6.1.4.1.318.1.1.26.6.3.1.5 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusVoltage OBJECT-TYPE Indicates the Voltage, in Volts, of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.6.3.1.6 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusPower OBJECT-TYPE Indicates the load power, in hundredths of kilowatts (kW), consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.6.3.1.7 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusApparentPower OBJECT-TYPE Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA), consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.6.3.1.8 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusPowerFactor OBJECT-TYPE Indicates the load power factor, in hundredths, of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.26.6.3.1.9 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusPeakCurrent OBJECT-TYPE The peak current of the Rack PDU phase load in tenths of Amps | 1.3.6.1.4.1.318.1.1.26.6.3.1.10 | INTEGER | read-only | mandatory |
| rPDU2PhaseStatusPeakCurrentTimestamp OBJECT-TYPE Indicates the date and time that the peak current occurred | 1.3.6.1.4.1.318.1.1.26.6.3.1.11 | DisplayString | read-only | mandatory |
| rPDU2PhaseStatusPeakCurrentStartTime OBJECT-TYPE Indicates the date and time of the last phase peak current reset | 1.3.6.1.4.1.318.1.1.26.6.3.1.12 | DisplayString | read-only | mandatory |
| rPDU2BankTableSize OBJECT-TYPE The number of connected Rack PDU banks | 1.3.6.1.4.1.318.1.1.26.7 | INTEGER | read-only | mandatory |
| rPDU2Bank OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.8 | |||
| rPDU2BankConfigTable OBJECT-TYPE A table of Rack PDU bank configuration data | 1.3.6.1.4.1.318.1.1.26.8.1 | not-accessible | mandatory | |
| rPDU2BankConfigEntry OBJECT-TYPE Configuration data from currently queried Rack PDU bank | 1.3.6.1.4.1.318.1.1.26.8.1.1 | not-accessible | mandatory | |
| rPDU2BankConfigIndex OBJECT-TYPE The index to the Rack PDU bank configuration table entry | 1.3.6.1.4.1.318.1.1.26.8.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2BankConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.8.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2BankConfigNumber OBJECT-TYPE The numeric bank ID | 1.3.6.1.4.1.318.1.1.26.8.1.1.3 | INTEGER | read-only | mandatory |
| rPDU2BankConfigOverloadRestriction OBJECT-TYPE This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the rPDU2BankConfigNearOverloadCurrentThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the rPDU2BankConfigOverloadCurrentThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.318.1.1.26.8.1.1.4 | INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3), notSupported(4)} | read-write | mandatory |
| rPDU2BankConfigLowLoadCurrentThreshold OBJECT-TYPE User-defined low load bank current threshold in Amps | 1.3.6.1.4.1.318.1.1.26.8.1.1.5 | INTEGER | read-write | mandatory |
| rPDU2BankConfigNearOverloadCurrentThreshold OBJECT-TYPE User-defined near bank overload current warning threshold in Amps | 1.3.6.1.4.1.318.1.1.26.8.1.1.6 | INTEGER | read-write | mandatory |
| rPDU2BankConfigOverloadCurrentThreshold OBJECT-TYPE User-defined bank overload current threshold in Amps | 1.3.6.1.4.1.318.1.1.26.8.1.1.7 | INTEGER | read-write | mandatory |
| rPDU2BankConfigBankPeakCurrentReset OBJECT-TYPE Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.26.8.1.1.8 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| rPDU2BankPropertiesTable OBJECT-TYPE A table of Rack PDU bank properties | 1.3.6.1.4.1.318.1.1.26.8.2 | not-accessible | mandatory | |
| rPDU2BankPropertiesEntry OBJECT-TYPE Properties of the currently queried Rack PDU bank | 1.3.6.1.4.1.318.1.1.26.8.2.1 | not-accessible | mandatory | |
| rPDU2BankPropertiesIndex OBJECT-TYPE The index to the Rack PDU bank properties table entry | 1.3.6.1.4.1.318.1.1.26.8.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2BankPropertiesModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.8.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2BankPropertiesNumber OBJECT-TYPE The numeric bank ID | 1.3.6.1.4.1.318.1.1.26.8.2.1.3 | INTEGER | read-only | mandatory |
| rPDU2BankPropertiesPhaseLayout OBJECT-TYPE This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that bank outlets are wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that bank outlets are wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that bank outlets are wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that bank outlets are wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that bank outlets are wired from Phase 3 to Phase 1. | 1.3.6.1.4.1.318.1.1.26.8.2.1.4 | Rpdu2OutletPhaseLayoutType | read-only | mandatory |
| rPDU2BankPropertiesBreakerRating OBJECT-TYPE If bank circuit breakers are present on the device, this OID will return the rating of the breaker in Amps. | 1.3.6.1.4.1.318.1.1.26.8.2.1.5 | INTEGER | read-only | mandatory |
| rPDU2BankStatusTable OBJECT-TYPE A table of Rack PDU bank status data | 1.3.6.1.4.1.318.1.1.26.8.3 | not-accessible | mandatory | |
| rPDU2BankStatusEntry OBJECT-TYPE Status data from currently queried Rack PDU bank | 1.3.6.1.4.1.318.1.1.26.8.3.1 | not-accessible | mandatory | |
| rPDU2BankStatusIndex OBJECT-TYPE The index to the Rack PDU bank status table entry | 1.3.6.1.4.1.318.1.1.26.8.3.1.1 | INTEGER | read-only | mandatory |
| rPDU2BankStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.8.3.1.2 | INTEGER | read-only | mandatory |
| rPDU2BankStatusNumber OBJECT-TYPE The numeric bank ID | 1.3.6.1.4.1.318.1.1.26.8.3.1.3 | INTEGER | read-only | mandatory |
| rPDU2BankStatusLoadState OBJECT-TYPE Indicates the present load status of the Rack PDU bank being queried | 1.3.6.1.4.1.318.1.1.26.8.3.1.4 | INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4)} | read-only | mandatory |
| rPDU2BankStatusCurrent OBJECT-TYPE Indicates the current draw, in tenths of Amps, of the load on the Rack PDU bank being queried | 1.3.6.1.4.1.318.1.1.26.8.3.1.5 | INTEGER | read-only | mandatory |
| rPDU2BankStatusPeakCurrent OBJECT-TYPE The peak current of the Rack PDU bank load in tenths of Amps | 1.3.6.1.4.1.318.1.1.26.8.3.1.6 | INTEGER | read-only | mandatory |
| rPDU2BankStatusPeakCurrentTimestamp OBJECT-TYPE Indicates the date and time the bank peak current occurred | 1.3.6.1.4.1.318.1.1.26.8.3.1.7 | DisplayString | read-only | mandatory |
| rPDU2BankStatusPeakCurrentStartTime OBJECT-TYPE Indicates the date and time of the last bank peak current reset | 1.3.6.1.4.1.318.1.1.26.8.3.1.8 | DisplayString | read-only | mandatory |
| rPDU2Outlet OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.9 | |||
| rPDU2OutletSwitchedTableSize OBJECT-TYPE The number of switched outlets on connected Rack PDUs | 1.3.6.1.4.1.318.1.1.26.9.1 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitched OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.9.2 | |||
| rPDU2OutletSwitchedConfigTable OBJECT-TYPE A table of Rack PDU switched outlet configuration data | 1.3.6.1.4.1.318.1.1.26.9.2.1 | not-accessible | mandatory | |
| rPDU2OutletSwitchedConfigEntry OBJECT-TYPE Configuration data from currently queried Rack PDU switched outlet | 1.3.6.1.4.1.318.1.1.26.9.2.1.1 | not-accessible | mandatory | |
| rPDU2OutletSwitchedConfigIndex OBJECT-TYPE The index to the Rack PDU switched outlet configuration table entry | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedConfigName OBJECT-TYPE The user-defined switched outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.3 | DisplayString | read-write | mandatory |
| rPDU2OutletSwitchedConfigNumber OBJECT-TYPE The numeric switched outlet ID | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedConfigPowerOnTime OBJECT-TYPE The amount of delay, in seconds, between when power is provided to the Rack PDU and when this switched outlet starts providing power. Range -1...300 where -1 = Never power on, 0 = immediate power on, and 1-300 = seconds to delay. | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.5 | INTEGER | read-write | mandatory |
| rPDU2OutletSwitchedConfigPowerOffTime OBJECT-TYPE The amount of time, in seconds, this outlet will delay powering off. Range -1...360 where -1 = Never power off, 0 = immediate power off, and 1-360 = seconds to delay. | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.6 | INTEGER | read-write | mandatory |
| rPDU2OutletSwitchedConfigRebootDuration OBJECT-TYPE After turning power off during a reboot sequence, the amount of time to wait before turning power to this outlet back on. Range 5-60 seconds delay. | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.7 | INTEGER | read-write | mandatory |
| rPDU2OutletSwitchedConfigExternalLink OBJECT-TYPE User-defined external device web link. Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications, drivers, etc. | 1.3.6.1.4.1.318.1.1.26.9.2.1.1.8 | DisplayString | read-write | mandatory |
| rPDU2OutletSwitchedPropertiesTable OBJECT-TYPE A table of Rack PDU switched outlet properties | 1.3.6.1.4.1.318.1.1.26.9.2.2 | not-accessible | mandatory | |
| rPDU2OutletSwitchedPropertiesEntry OBJECT-TYPE Properties of the currently queried Rack PDU switched outlet | 1.3.6.1.4.1.318.1.1.26.9.2.2.1 | not-accessible | mandatory | |
| rPDU2OutletSwitchedPropertiesIndex OBJECT-TYPE The index to the Rack PDU switched outlet properties table entry | 1.3.6.1.4.1.318.1.1.26.9.2.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedPropertiesModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.2.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedPropertiesName OBJECT-TYPE The user-defined switched outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.2.2.1.3 | DisplayString | read-only | mandatory |
| rPDU2OutletSwitchedPropertiesNumber OBJECT-TYPE The numeric switched outlet ID | 1.3.6.1.4.1.318.1.1.26.9.2.2.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedPropertiesPhaseLayout OBJECT-TYPE This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1. | 1.3.6.1.4.1.318.1.1.26.9.2.2.1.5 | Rpdu2OutletPhaseLayoutType | read-only | mandatory |
| rPDU2OutletSwitchedPropertiesBank OBJECT-TYPE The numeric bank ID | 1.3.6.1.4.1.318.1.1.26.9.2.2.1.6 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedStatusTable OBJECT-TYPE A table of Rack PDU switched outlet status information | 1.3.6.1.4.1.318.1.1.26.9.2.3 | not-accessible | mandatory | |
| rPDU2OutletSwitchedStatusEntry OBJECT-TYPE Status information for currently queried Rack PDU switched outlet | 1.3.6.1.4.1.318.1.1.26.9.2.3.1 | not-accessible | mandatory | |
| rPDU2OutletSwitchedStatusIndex OBJECT-TYPE The index to the Rack PDU switched outlet status information table entry | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedStatusName OBJECT-TYPE The user-defined switched outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.3 | DisplayString | read-only | mandatory |
| rPDU2OutletSwitchedStatusNumber OBJECT-TYPE The numeric switched outlet ID | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedStatusState OBJECT-TYPE Indicates the present switch state of the Rack PDU switched outlet being queried | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.5 | INTEGER {off(1), on(2)} | read-only | mandatory |
| rPDU2OutletSwitchedStatusCommandPending OBJECT-TYPE Indicates whether or not the device is processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cycled to clear this condition. | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.6 | INTEGER {commandPending(1), noCommandPending(2), commandPendingUnknown(3)} | read-only | mandatory |
| rPDU2OutletSwitchedStatusExternalLink OBJECT-TYPE Each RPDU outlet can have its own external web URL link. This can be configured in the rPDU2OutletSwitchedConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web browser. | 1.3.6.1.4.1.318.1.1.26.9.2.3.1.7 | DisplayString | read-only | mandatory |
| rPDU2OutletSwitchedControlTable OBJECT-TYPE A table of Rack PDU switched outlet control data | 1.3.6.1.4.1.318.1.1.26.9.2.4 | not-accessible | mandatory | |
| rPDU2OutletSwitchedControlEntry OBJECT-TYPE Control data for currently queried Rack PDU switched outlet | 1.3.6.1.4.1.318.1.1.26.9.2.4.1 | not-accessible | mandatory | |
| rPDU2OutletSwitchedControlIndex OBJECT-TYPE The index to the Rack PDU switched outlet control data table entry | 1.3.6.1.4.1.318.1.1.26.9.2.4.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedControlModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.2.4.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedControlName OBJECT-TYPE The user-defined switched outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.2.4.1.3 | DisplayString | read-only | mandatory |
| rPDU2OutletSwitchedControlNumber OBJECT-TYPE The numeric switched outlet ID | 1.3.6.1.4.1.318.1.1.26.9.2.4.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletSwitchedControlCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will cause the Switched Rack PDU to perform an immediateOff command, wait the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateOn command. Setting this variable to delayedOn (5) will turn the outlet on after the rPDU2OutletSwitchedConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (6) will turn the outlet off after the rPDU2OutletSwitchedConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (7) will cause the Switched Rack PDU to perform a delayedOff command, wait the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (8) will cause any pending command to this outlet to be cancelled. | 1.3.6.1.4.1.318.1.1.26.9.2.4.1.5 | INTEGER {immediateOn(1), immediateOff(2), immediateReboot(3), outletUnknown(4), delayedOn(5), delayedOff(6), delayedReboot(7), cancelPendingCommand(8)} | read-write | mandatory |
| rPDU2OutletMeteredTableSize OBJECT-TYPE The number of metered outlets on connect Rack PDUs | 1.3.6.1.4.1.318.1.1.26.9.3 | INTEGER | read-only | mandatory |
| rPDU2OutletMetered OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.9.4 | |||
| rPDU2OutletMeteredConfigTable OBJECT-TYPE A table of Rack PDU metered outlet configuration data | 1.3.6.1.4.1.318.1.1.26.9.4.1 | not-accessible | mandatory | |
| rPDU2OutletMeteredConfigEntry OBJECT-TYPE Configuration data from currently queried Rack PDU metered outlet | 1.3.6.1.4.1.318.1.1.26.9.4.1.1 | not-accessible | mandatory | |
| rPDU2OutletMeteredConfigIndex OBJECT-TYPE The index to the Rack PDU metered outlet configuration table entry | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredConfigName OBJECT-TYPE The user-defined metered outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.3 | DisplayString | read-write | mandatory |
| rPDU2OutletMeteredConfigNumber OBJECT-TYPE The numeric switched outlet ID | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredConfigLowLoadCurrentThreshold OBJECT-TYPE User-defined low load outlet current threshold in Watts | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.5 | INTEGER | read-write | mandatory |
| rPDU2OutletMeteredConfigNearOverloadCurrentThreshold OBJECT-TYPE User-defined near outlet overload warning threshold in Watts | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.6 | INTEGER | read-write | mandatory |
| rPDU2OutletMeteredConfigOverloadCurrentThreshold OBJECT-TYPE User-defined outlet overload current threshold in Watts | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.7 | INTEGER | read-write | mandatory |
| rPDU2OutletMeteredConfigExternalLink OBJECT-TYPE User-defined external device web link. Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications, drivers, etc. | 1.3.6.1.4.1.318.1.1.26.9.4.1.1.8 | DisplayString | read-write | mandatory |
| rPDU2OutletMeteredPropertiesTable OBJECT-TYPE A table of Rack PDU metered outlet properties | 1.3.6.1.4.1.318.1.1.26.9.4.2 | not-accessible | mandatory | |
| rPDU2OutletMeteredPropertiesEntry OBJECT-TYPE Properties of currently queried Rack PDU metered outlet | 1.3.6.1.4.1.318.1.1.26.9.4.2.1 | not-accessible | mandatory | |
| rPDU2OutletMeteredPropertiesIndex OBJECT-TYPE The index to the Rack PDU metered properties table entry | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredPropertiesModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredPropertiesName OBJECT-TYPE The user-defined metered outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.3 | DisplayString | read-only | mandatory |
| rPDU2OutletMeteredPropertiesNumber OBJECT-TYPE The numeric metered outlet ID | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredPropertiesLayout OBJECT-TYPE This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1. | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.5 | Rpdu2OutletPhaseLayoutType | read-only | mandatory |
| rPDU2OutletMeteredPropertiesPowerRating OBJECT-TYPE Maximum power rating of Rack PDU metered outlet | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.6 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredPropertiesBank OBJECT-TYPE This outlet's numeric bank ID | 1.3.6.1.4.1.318.1.1.26.9.4.2.1.7 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusTable OBJECT-TYPE A table of Rack PDU metered outlet status data | 1.3.6.1.4.1.318.1.1.26.9.4.3 | not-accessible | mandatory | |
| rPDU2OutletMeteredStatusEntry OBJECT-TYPE Status data from currently queried Rack PDU metered outlet | 1.3.6.1.4.1.318.1.1.26.9.4.3.1 | not-accessible | mandatory | |
| rPDU2OutletMeteredStatusIndex OBJECT-TYPE The index to the Rack PDU metered status table entry | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.1 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.2 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusName OBJECT-TYPE The user-defined metered outlet ID string | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.3 | DisplayString | read-only | mandatory |
| rPDU2OutletMeteredStatusNumber OBJECT-TYPE The numeric metered outlet ID | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.4 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusState OBJECT-TYPE Indicates the present load status of the Rack PDU metered outlet being queried | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.5 | INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4)} | read-only | mandatory |
| rPDU2OutletMeteredStatusCurrent OBJECT-TYPE Indicates the current draw, in tenths of Amps, of the load on the Rack PDU outlet being queried | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.6 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusPower OBJECT-TYPE Indicates the power draw of the load on the Rack PDU outlet being queried | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.7 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusPeakPower OBJECT-TYPE Indicates the peak power load draw on the Rack PDU outlet being queried | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.8 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusPeakPowerTimestamp OBJECT-TYPE Indicates the date and time that this metered outlet's peak power consumption occurred | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.9 | DisplayString | read-only | mandatory |
| rPDU2OutletMeteredStatusPeakPowerStartTime OBJECT-TYPE Indicates the start date and time that this metered outlet began recording peak power observations | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.10 | DisplayString | read-only | mandatory |
| rPDU2OutletMeteredStatusEnergy OBJECT-TYPE A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.11 | INTEGER | read-only | mandatory |
| rPDU2OutletMeteredStatusReceptacleType OBJECT-TYPE Indicates receptacle type for the outlet. | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.12 | DisplayString | read-only | mandatory |
| rPDU2OutletMeteredStatusExternalLink OBJECT-TYPE Each RPDU outlet can have its own external web URL link. This can be configured in the rPDU2OutletMeteredConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web browser. | 1.3.6.1.4.1.318.1.1.26.9.4.3.1.13 | DisplayString | read-only | mandatory |
| rPDU2Sensor OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.10 | |||
| rPDU2SensorTempHumidityTableSize OBJECT-TYPE The number of connected temperature-humidity sensors | 1.3.6.1.4.1.318.1.1.26.10.1 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidity OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.10.2 | |||
| rPDU2SensorTempHumidityConfigTable OBJECT-TYPE A table of temperature-humidity sensor configuration data | 1.3.6.1.4.1.318.1.1.26.10.2.1 | not-accessible | mandatory | |
| rPDU2SensorTempHumidityConfigEntry OBJECT-TYPE Configuration data from temperature-humidity sensor being queried | 1.3.6.1.4.1.318.1.1.26.10.2.1.1 | not-accessible | mandatory | |
| rPDU2SensorTempHumidityConfigIndex OBJECT-TYPE The index to the temperature-humidity sensor configuration data table entry | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityConfigName OBJECT-TYPE The user-defined temperature-humidity sensor ID string | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.3 | DisplayString | read-write | mandatory |
| rPDU2SensorTempHumidityConfigNumber OBJECT-TYPE The temperature-humidity sensor numeric ID | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.4 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityConfigTemperatureAlarmEnable OBJECT-TYPE Setting this OID enables or disables generation of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.5 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| rPDU2SensorTempHumidityConfigHumidityAlarmEnable OBJECT-TYPE Setting this OID enables or disables generation of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempMaxThreshF OBJECT-TYPE Sensor maximum temperature alarm threshold in Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshF will result in an error. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.7 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempHighThreshF OBJECT-TYPE Sensor high temperature warning alarm threshold in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshF will result in an error. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.8 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempHysteresisF OBJECT-TYPE Sensor temperature hysteresis setting in Fahrenheit | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.9 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempMaxThreshC OBJECT-TYPE Sensor maximum temperature alarm threshold in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshC will result in an error. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.10 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempHighThreshC OBJECT-TYPE Sensor high temperature warning alarm threshold in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshC will result in an error. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.11 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempHysteresisC OBJECT-TYPE Sensor temperature hysteresis setting in Celsius | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.12 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigHumidityLowThresh OBJECT-TYPE Sensor low humidity warning alarm threshold in percent relative humidity. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigHumidityMinThresh will result in an error. Must be between 15% and 90% | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.13 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigHumidityMinThresh OBJECT-TYPE Sensor minimum humidity alarm threshold in percent relative humidity. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigHumidityLowThresh will result in an error. Must be between 15% and 90% | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.14 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigHumidityHysteresis OBJECT-TYPE Sensor humidity hysteresis setting in percent relative humidity | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.15 | INTEGER | read-write | mandatory |
| rPDU2SensorTempHumidityConfigTempPeakReset OBJECT-TYPE Setting this OID to reset (2) will cause the existing peak temperature to be replaced by the present temperature reading. Getting this OID will do nothing and return the noOperation(1) value. | 1.3.6.1.4.1.318.1.1.26.10.2.1.1.16 | INTEGER {noOperation(1), reset(2)} | read-write | mandatory |
| rPDU2SensorTempHumidityStatusTable OBJECT-TYPE A table of temperature-humidity sensor status data | 1.3.6.1.4.1.318.1.1.26.10.2.2 | not-accessible | mandatory | |
| rPDU2SensorTempHumidityStatusEntry OBJECT-TYPE Status information from temperature-humidity sensor being queried | 1.3.6.1.4.1.318.1.1.26.10.2.2.1 | not-accessible | mandatory | |
| rPDU2SensorTempHumidityStatusIndex OBJECT-TYPE The index to the temperature-humidity status data table entry | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusName OBJECT-TYPE The user-defined temperature-humidity sensor ID string | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.3 | DisplayString | read-only | mandatory |
| rPDU2SensorTempHumidityStatusNumber OBJECT-TYPE The temperature-humidity sensor numeric ID | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.4 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusType OBJECT-TYPE The type of the sensor | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.5 | INTEGER {temperatureOnly(1), temperatureHumidity(2), commsLost(3), notInstalled(4)} | read-only | mandatory |
| rPDU2SensorTempHumidityStatusCommStatus OBJECT-TYPE The communications status of the sensor | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.6 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempF OBJECT-TYPE Sensor temperature reading in tenths of degrees Fahrenheit | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.7 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempC OBJECT-TYPE Sensor temperature reading in tenths of degrees Celsius | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.8 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempStatus OBJECT-TYPE This OID reports the current state of the temperature probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured temperature lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured temperature lies below the low threshold. A normal (4) response indicates that the probe is present and its measured temperature lies within all temperature thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a temperature above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a temperature above the max threshold. | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.9 | INTEGER {notPresent(1), belowMin(2), belowLow(3), normal(4), aboveHigh(5), aboveMax(6)} | read-only | mandatory |
| rPDU2SensorTempHumidityStatusRelativeHumidity OBJECT-TYPE Sensor humidity reading in percent relative humidity | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.10 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusHumidityStatus OBJECT-TYPE This OID reports the current state of the humidity probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidity lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured humidity lies below the low threshold. A normal (4) response indicates that the probe is present and its measured humidity lies within all humidity thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a humidity above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a humidity above the max threshold. | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.11 | INTEGER {notPresent(1), belowMin(2), belowLow(3), normal(4), aboveHigh(5), aboveMax(6)} | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempPeakF OBJECT-TYPE Sensor peak temperature in tenths of degrees Fahrenheit | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.12 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempPeakC OBJECT-TYPE Sensor peak temperature in tenths of degrees Celsius | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.13 | INTEGER | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempPeakTimestamp OBJECT-TYPE Indicates the date and time that the peak temperature occurred | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.14 | DisplayString | read-only | mandatory |
| rPDU2SensorTempHumidityStatusTempPeakStartTime OBJECT-TYPE Indicates the date and time of the last temperature peak reset | 1.3.6.1.4.1.318.1.1.26.10.2.2.1.15 | DisplayString | read-only | mandatory |
| rPDU2SensorDiscreteTableSize OBJECT-TYPE The number of connected discrete sensors | 1.3.6.1.4.1.318.1.1.26.10.3 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscrete OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.10.4 | |||
| rPDU2SensorDiscreteConfigTable OBJECT-TYPE A table of discrete sensor configuration data | 1.3.6.1.4.1.318.1.1.26.10.4.1 | not-accessible | mandatory | |
| rPDU2SensorDiscreteConfigEntry OBJECT-TYPE Configuration data from discreste sensor being queried | 1.3.6.1.4.1.318.1.1.26.10.4.1.1 | not-accessible | mandatory | |
| rPDU2SensorDiscreteConfigIndex OBJECT-TYPE The index to the discrete sensor configuration data table entry | 1.3.6.1.4.1.318.1.1.26.10.4.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscreteConfigModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.10.4.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscreteConfigName OBJECT-TYPE The user-defined discrete sensor ID string | 1.3.6.1.4.1.318.1.1.26.10.4.1.1.3 | DisplayString | read-write | mandatory |
| rPDU2SensorDiscreteConfigNumber OBJECT-TYPE The discrete sensor numeric ID | 1.3.6.1.4.1.318.1.1.26.10.4.1.1.4 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscreteConfigNormalState OBJECT-TYPE Indicates the normal state of the discrete input contact | 1.3.6.1.4.1.318.1.1.26.10.4.1.1.5 | INTEGER {normallyOpen(1), normallyClosed(2)} | read-write | mandatory |
| rPDU2SensorDiscreteConfigAbnormalSeverity OBJECT-TYPE Indicates the severity of alarm triggered by abnormal discrete input contact state | 1.3.6.1.4.1.318.1.1.26.10.4.1.1.6 | INTEGER {informational(1), warning(2), critical(3)} | read-write | mandatory |
| rPDU2SensorDiscreteStatusTable OBJECT-TYPE A table of discrete sensor status data | 1.3.6.1.4.1.318.1.1.26.10.4.2 | not-accessible | mandatory | |
| rPDU2SensorDiscreteStatusEntry OBJECT-TYPE Status information from discrete sensor being queried | 1.3.6.1.4.1.318.1.1.26.10.4.2.1 | not-accessible | mandatory | |
| rPDU2SensorDiscreteStatusIndex OBJECT-TYPE The index to the discrete sensor status data table entry | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.1 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscreteStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.2 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscreteStatusName OBJECT-TYPE The user-defined discrete sensor ID string | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.3 | DisplayString | read-only | mandatory |
| rPDU2SensorDiscreteStatusNumber OBJECT-TYPE The discrete sensor numeric ID | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.4 | INTEGER | read-only | mandatory |
| rPDU2SensorDiscreteStatusType OBJECT-TYPE The type of discrete sensor currently being queried | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.5 | INTEGER {notConnected(1), doorContactSensor(2), smokeSensor(3), motionDetector(4), vibrationSensor(5), dryContactSensor(6), spotLeakSensor(7)} | read-only | mandatory |
| rPDU2SensorDiscreteStatusCommStatus OBJECT-TYPE The communications status of the sensor | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.6 | INTEGER {notInstalled(1), commsOK(2), commsLost(3)} | read-only | mandatory |
| rPDU2SensorDiscreteStatusCurrentState OBJECT-TYPE The current open/close state of the discrete sensor | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.7 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| rPDU2SensorDiscreteStatusAlarmState OBJECT-TYPE Indicates alarm status of discrete sensor input | 1.3.6.1.4.1.318.1.1.26.10.4.2.1.8 | INTEGER {normal(1), alarm(2)} | read-only | mandatory |
| rPDU2Group OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.11 | |||
| rPDU2GroupNumberOfDevices OBJECT-TYPE Getting this OID will return the number of Rack PDU devices contributing to the Network Port Sharing (NPS) group power and energy values. Queries to guest units in an NPS group are not applicable and will return 0. | 1.3.6.1.4.1.318.1.1.26.11.1 | INTEGER | read-only | mandatory |
| rPDU2GroupTotalPower OBJECT-TYPE Getting this OID will return the total power consumption of the Rack PDU Network Port Sharing (NPS) group devices in hundredths of kilowatts. Queries to guest units in an NPS group are not applicable and will return 0. | 1.3.6.1.4.1.318.1.1.26.11.2 | INTEGER | read-only | mandatory |
| rPDU2GroupTotalEnergy OBJECT-TYPE Getting this OID will return the total energy consumption of the Rack PDU Network Port Sharing (NPS) group devices in tenths of kilowatt-hours. To reset the energy meters for each of the Rack PDU devices that contribute to this value, see the rPDU2GroupEnergyReset OID. To view the start time for each of the Rack PDU device energy meters that contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID. Queries to guest units in an NPS group are not applicable and will return 0. | 1.3.6.1.4.1.318.1.1.26.11.3 | INTEGER | read-only | mandatory |
| rPDU2GroupEnergyReset OBJECT-TYPE Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU Network Port Sharing (NPS) group to be reset to zero. Each device in the Rack PDU group will also have its corresponding rPDU2DeviceStatusEnergyStartTime OID value updated. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature, as well as guest units in an NPS group, will respond to this OID with a value of notSupported (3). Attempts to set this OID in these units will fail. | 1.3.6.1.4.1.318.1.1.26.11.4 | INTEGER {noOperation(1), reset(2), notSupported(3)} | read-write | mandatory |
| rPDU2PhaseToPhaseStatusTableSize OBJECT-TYPE The number of connected Rack PDU banks | 1.3.6.1.4.1.318.1.1.26.12 | INTEGER | read-only | mandatory |
| rPDU2PhaseToPhase OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.26.13 | |||
| rPDU2PhaseToPhaseStatusTable OBJECT-TYPE A table of Rack PDU phase to phase status data. This table is only applicable to SKUs that have phase to phase outputs. | 1.3.6.1.4.1.318.1.1.26.13.1 | not-accessible | mandatory | |
| rPDU2PhaseToPhaseStatusEntry OBJECT-TYPE Status data from currently queried Rack PDU phase to phase outputs | 1.3.6.1.4.1.318.1.1.26.13.1.1 | not-accessible | mandatory | |
| rPDU2PhaseToPhaseStatusIndex OBJECT-TYPE The index to the Rack PDU phase to phase status table entry | 1.3.6.1.4.1.318.1.1.26.13.1.1.1 | INTEGER | read-only | mandatory |
| rPDU2PhaseToPhaseStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.26.13.1.1.2 | INTEGER | read-only | mandatory |
| rPDU2PhaseToPhaseStatusVoltage1to2 OBJECT-TYPE Indicates the Voltage, in Volts, of the Rack PDU phase 1 to phase 2 output being queried | 1.3.6.1.4.1.318.1.1.26.13.1.1.3 | INTEGER | read-only | mandatory |
| rPDU2PhaseToPhaseStatusVoltage2to3 OBJECT-TYPE Indicates the Voltage, in Volts, of the Rack PDU phase 2 to phase 3 output being queried | 1.3.6.1.4.1.318.1.1.26.13.1.1.4 | INTEGER | read-only | mandatory |
| rPDU2PhaseToPhaseStatusVoltage3to1 OBJECT-TYPE Indicates the Voltage, in Volts, of the Rack PDU phase 3 to phase 2 output being queried | 1.3.6.1.4.1.318.1.1.26.13.1.1.5 | INTEGER | read-only | mandatory |
| cooling OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27 | |||
| coolingUnit OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1 | |||
| coolingUnitTableSize OBJECT-TYPE The number of cooling units accessible via this agent. | 1.3.6.1.4.1.318.1.1.27.1.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitTable OBJECT-TYPE A table of cooling unit level data. | 1.3.6.1.4.1.318.1.1.27.1.2 | not-accessible | mandatory | |
| coolingUnitEntry OBJECT-TYPE An element of coolingUnitTable. | 1.3.6.1.4.1.318.1.1.27.1.2.1 | not-accessible | mandatory | |
| coolingUnitTableIndex OBJECT-TYPE The unit reference identifier for this table and all other table entries subordinate to coolingUnits. | 1.3.6.1.4.1.318.1.1.27.1.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitAbout OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.3 | |||
| coolingUnitAboutTableSize OBJECT-TYPE The potential number of entries available in coolingUnitAboutTable. | 1.3.6.1.4.1.318.1.1.27.1.3.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitAboutTable OBJECT-TYPE A table of unit reference information. | 1.3.6.1.4.1.318.1.1.27.1.3.2 | not-accessible | mandatory | |
| coolingUnitAboutEntry OBJECT-TYPE An element of coolingUnitAboutTable. | 1.3.6.1.4.1.318.1.1.27.1.3.2.1 | not-accessible | mandatory | |
| coolingUnitAboutTableIndex OBJECT-TYPE The static reference identifier for each table entry. | 1.3.6.1.4.1.318.1.1.27.1.3.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitAboutDescription OBJECT-TYPE A text description of the information presented in coolingUnitAboutValue. | 1.3.6.1.4.1.318.1.1.27.1.3.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitAboutValue OBJECT-TYPE The actual value of the current table entry. | 1.3.6.1.4.1.318.1.1.27.1.3.2.1.3 | DisplayString | read-only | mandatory |
| coolingUnitStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.4 | |||
| coolingUnitStatusAnalog OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.4.1 | |||
| coolingUnitStatusAnalogTableSize OBJECT-TYPE The potential number of entries available in coolingUnitStatusAnalogTable. | 1.3.6.1.4.1.318.1.1.27.1.4.1.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitStatusAnalogTable OBJECT-TYPE A table of analog unit status data. | 1.3.6.1.4.1.318.1.1.27.1.4.1.2 | not-accessible | mandatory | |
| coolingUnitStatusAnalogEntry OBJECT-TYPE An element of coolingUnitStatusAnalogTable. | 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1 | not-accessible | mandatory | |
| coolingUnitStatusAnalogTableIndex OBJECT-TYPE The static reference identifier for each table entry. | 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitStatusAnalogDescription OBJECT-TYPE A text description of the information presented in coolingUnitStatusAnalogValue. | 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitStatusAnalogValue OBJECT-TYPE The scaled value of the current table entry (multiplied by coolingUnitStatusAnalogScale for integer presentation). | 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.3 | INTEGER | read-only | mandatory |
| coolingUnitStatusAnalogUnits OBJECT-TYPE The unit of measure by which coolingUnitStatusAnalogValue is expressed. | 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.4 | DisplayString | read-only | mandatory |
| coolingUnitStatusAnalogScale OBJECT-TYPE The factor by which coolingUnitStatusAnalogValue is expressed. | 1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.5 | INTEGER | read-only | mandatory |
| coolingUnitStatusDiscrete OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.4.2 | |||
| coolingUnitStatusDiscreteTableSize OBJECT-TYPE The potential number of entries available in coolingUnitStatusDiscreteTable. | 1.3.6.1.4.1.318.1.1.27.1.4.2.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitStatusDiscreteTable OBJECT-TYPE A table of discrete unit status data. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2 | not-accessible | mandatory | |
| coolingUnitStatusDiscreteEntry OBJECT-TYPE An element of coolingUnitStatusDiscreteTable. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1 | not-accessible | mandatory | |
| coolingUnitStatusDiscreteTableIndex OBJECT-TYPE The static reference identifier for each table entry. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitStatusDiscreteDescription OBJECT-TYPE A text description of the information presented in this table's 'value' OIDs. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitStatusDiscreteValueAsString OBJECT-TYPE The actual value of the current table entry expressed as a string. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.3 | DisplayString | read-only | mandatory |
| coolingUnitStatusDiscreteValueAsInteger OBJECT-TYPE The actual value of the current table entry expressed as an integer value. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.4 | INTEGER | read-only | mandatory |
| coolingUnitStatusDiscreteIntegerReferenceKey OBJECT-TYPE A complete listing of all possible coolingUnitStatusDiscreteValueAsInteger values paired with their identifying strings. | 1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.5 | DisplayString | read-only | mandatory |
| coolingUnitConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.5 | |||
| coolingUnitConfigurationAnalog OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.5.1 | |||
| coolingUnitConfigurationAnalogTableSize OBJECT-TYPE The potential number of entries available in coolingUnitConfigurationAnalogTable. | 1.3.6.1.4.1.318.1.1.27.1.5.1.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitConfigurationAnalogTable OBJECT-TYPE A table of analog unit configuration data. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2 | not-accessible | mandatory | |
| coolingUnitConfigurationAnalogEntry OBJECT-TYPE An element of coolingUnitConfigurationAnalogTable. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1 | not-accessible | mandatory | |
| coolingUnitConfigurationAnalogTableIndex OBJECT-TYPE The static reference identifier for each table entry. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitConfigurationAnalogDescription OBJECT-TYPE A text description of the information presented in coolingUnitConfigurationAnalogValue. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitConfigurationAnalogValue OBJECT-TYPE The scaled value of the current table entry (multiplied by coolingUnitConfigurationAnalogScale for integer presentation). | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.3 | INTEGER | read-write | mandatory |
| coolingUnitConfigurationAnalogUnits OBJECT-TYPE The unit of measure by which coolingUnitConfigurationAnalogValue is expressed. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.4 | DisplayString | read-only | mandatory |
| coolingUnitConfigurationAnalogScale OBJECT-TYPE The factor by which coolingUnitConfigurationAnalogValue is expressed. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.5 | INTEGER | read-only | mandatory |
| coolingUnitConfigurationAnalogAccess OBJECT-TYPE A description of available access to coolingUnitConfigurationAnalogValue via SNMP client. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.6 | INTEGER {readOnly(1), readWrite(2)} | read-only | mandatory |
| coolingUnitConfigurationAnalogMinimum OBJECT-TYPE The minimum possible value of coolingUnitConfigurationAnalogValue. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.7 | INTEGER | read-only | mandatory |
| coolingUnitConfigurationAnalogMaximum OBJECT-TYPE The maximum possible value of coolingUnitConfigurationAnalogValue. | 1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.8 | INTEGER | read-only | mandatory |
| coolingUnitConfigurationDiscrete OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.5.2 | |||
| coolingUnitConfigurationDiscreteTableSize OBJECT-TYPE The potential number of entries available in coolingUnitConfigurationDiscreteTable. | 1.3.6.1.4.1.318.1.1.27.1.5.2.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitConfigurationDiscreteTable OBJECT-TYPE A table of discrete unit configuration data. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2 | not-accessible | mandatory | |
| coolingUnitConfigurationDiscreteEntry OBJECT-TYPE An element of coolingUnitConfigurationDiscreteTable. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1 | not-accessible | mandatory | |
| coolingUnitConfigurationDiscreteTableIndex OBJECT-TYPE The static reference identifier for each table entry. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitConfigurationDiscreteDescription OBJECT-TYPE A text description of the information presented in this table's 'value' OIDs. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitConfigurationDiscreteValueAsString OBJECT-TYPE The actual value of the current table entry expressed as a string. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.3 | DisplayString | read-only | mandatory |
| coolingUnitConfigurationDiscreteValueAsInteger OBJECT-TYPE The actual value of the current table entry expressed as an integer value. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.4 | INTEGER | read-write | mandatory |
| coolingUnitConfigurationDiscreteIntegerReferenceKey OBJECT-TYPE A complete listing of all possible coolingUnitConfigurationDiscreteValueAsInteger values paired with their identifying strings. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.5 | DisplayString | read-only | mandatory |
| coolingUnitConfigurationDiscreteAccess OBJECT-TYPE A description of available access to coolingUnitConfigurationDiscreteValueAsInteger via SNMP client. | 1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.6 | INTEGER {readOnly(1), readWrite(2)} | read-only | mandatory |
| coolingUnitConfigurationString OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.5.3 | |||
| coolingUnitConfigurationStringTableSize OBJECT-TYPE The potential number of entries available in coolingUnitConfigurationStringTable. | 1.3.6.1.4.1.318.1.1.27.1.5.3.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitConfigurationStringTable OBJECT-TYPE A table of unit configuration strings. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2 | not-accessible | mandatory | |
| coolingUnitConfigurationStringEntry OBJECT-TYPE An element of coolingUnitConfigurationStringTable. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1 | not-accessible | mandatory | |
| coolingUnitConfigurationStringTableIndex OBJECT-TYPE The static reference identifier for each table entry. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitConfigurationStringDescription OBJECT-TYPE A text description of the information presented in coolingUnitConfigurationStringValue. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitConfigurationStringValue OBJECT-TYPE The actual value of the current table entry. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.3 | DisplayString | read-write | mandatory |
| coolingUnitConfigurationStringMaxLength OBJECT-TYPE The maximum string length supported by coolingUnitConfigurationStringValue. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.4 | INTEGER | read-only | mandatory |
| coolingUnitConfigurationStringAccess OBJECT-TYPE A description of available access to coolingUnitConfigurationStringValue via SNMP client. | 1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.5 | INTEGER {readOnly(1), readWrite(2)} | read-only | mandatory |
| coolingUnitExtended OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.6 | |||
| coolingUnitExtendedAnalog OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.6.1 | |||
| coolingUnitExtendedAnalogTableSize OBJECT-TYPE The potential number of entries available in coolingUnitExtendedAnalogTable. | 1.3.6.1.4.1.318.1.1.27.1.6.1.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitExtendedAnalogTable OBJECT-TYPE A table of secondary analog data for the cooling unit or one of its components. | 1.3.6.1.4.1.318.1.1.27.1.6.1.2 | not-accessible | mandatory | |
| coolingUnitExtendedAnalogEntry OBJECT-TYPE An element of coolingUnitExtendedAnalogTable. | 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1 | not-accessible | mandatory | |
| coolingUnitExtendedAnalogTableIndex OBJECT-TYPE The static reference identifier for each table entry. This identifier may reference different table entries in different unit models. | 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitExtendedAnalogDescription OBJECT-TYPE A text description of the information presented in coolingUnitExtendedAnalogValue. | 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitExtendedAnalogValue OBJECT-TYPE The scaled value of the current table entry (multiplied by coolingUnitExtendedAnalogScale for integer presentation). | 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.3 | INTEGER | read-only | mandatory |
| coolingUnitExtendedAnalogUnits OBJECT-TYPE The unit of measure by which coolingUnitExtendedAnalogValue is expressed. | 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.4 | DisplayString | read-only | mandatory |
| coolingUnitExtendedAnalogScale OBJECT-TYPE The factor by which coolingUnitExtendedAnalogValue is expressed. | 1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.5 | INTEGER | read-only | mandatory |
| coolingUnitExtendedDiscrete OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.6.2 | |||
| coolingUnitExtendedDiscreteTableSize OBJECT-TYPE The potential number of entries available in coolingUnitExtendedDiscreteTable. | 1.3.6.1.4.1.318.1.1.27.1.6.2.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitExtendedDiscreteTable OBJECT-TYPE A table of secondary discrete cooling unit data. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2 | not-accessible | mandatory | |
| coolingUnitExtendedDiscreteEntry OBJECT-TYPE An element of coolingUnitExtendedDiscreteTable. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1 | not-accessible | mandatory | |
| coolingUnitExtendedDiscreteTableIndex OBJECT-TYPE The static reference identifier for each table entry. This identifier may reference different table entries in different unit models. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitExtendedDiscreteDescription OBJECT-TYPE A text description of the information presented in this table's 'value' OIDs. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitExtendedDiscreteValueAsString OBJECT-TYPE The actual value of the current table entry expressed as a string. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.3 | DisplayString | read-only | mandatory |
| coolingUnitExtendedDiscreteValueAsInteger OBJECT-TYPE The actual value of the current table entry expressed as an integer value. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.4 | INTEGER | read-only | mandatory |
| coolingUnitExtendedDiscreteIntegerReferenceKey OBJECT-TYPE A complete listing of all possible coolingUnitExtendedDiscreteValueAsInteger values paired with their identifying strings. | 1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.5 | DisplayString | read-only | mandatory |
| coolingUnitExtendedString OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.27.1.6.3 | |||
| coolingUnitExtendedStringTableSize OBJECT-TYPE The potential number of entries available in coolingUnitExtendedStringTable. | 1.3.6.1.4.1.318.1.1.27.1.6.3.1 | INTEGER (0..2147483647) | read-only | mandatory |
| coolingUnitExtendedStringTable OBJECT-TYPE A table of secondary unit reference data. | 1.3.6.1.4.1.318.1.1.27.1.6.3.2 | not-accessible | mandatory | |
| coolingUnitExtendedStringEntry OBJECT-TYPE An element of coolingUnitExtendedStringTable. | 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1 | not-accessible | mandatory | |
| coolingUnitExtendedStringTableIndex OBJECT-TYPE The static reference identifier for each table entry. This identifier may reference different table entries in different unit models. | 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.1 | INTEGER (1..2147483647) | not-accessible | mandatory |
| coolingUnitExtendedStringDescription OBJECT-TYPE A text description of the information presented in coolingUnitExtendedStringValue. | 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.2 | DisplayString | read-only | mandatory |
| coolingUnitExtendedStringValue OBJECT-TYPE The actual value of the current table entry. | 1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.3 | DisplayString | read-only | mandatory |
| powerManagementModule OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28 | |||
| pmmIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.1 | |||
| pmmIdentModelNumber OBJECT-TYPE A character string identifying the model number of the PMM. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.28.1.1 | DisplayString | read-only | mandatory |
| pmmIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the PMM. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.28.1.2 | DisplayString | read-only | mandatory |
| pmmIdentDateOfManufacture OBJECT-TYPE The date when the PMM was manufactured in mm/dd/yyyy format. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.28.1.3 | DisplayString | read-only | mandatory |
| pmmIdentHMISerialNumber OBJECT-TYPE A character string identifying the serial number of the HMI. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.28.1.4 | DisplayString | read-only | mandatory |
| pmmIdentHMIHardwareRev OBJECT-TYPE The hardware revision of the HMI. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.28.1.5 | DisplayString | read-only | mandatory |
| pmmIdentHMIFirmwareAppRev OBJECT-TYPE An ID string identifying the application firmware revision of the HMI. | 1.3.6.1.4.1.318.1.1.28.1.6 | DisplayString | read-only | mandatory |
| pmmIdentHMIFirmwareAppOSRev OBJECT-TYPE An ID string identifying the application operating system firmware revision of the HMI. | 1.3.6.1.4.1.318.1.1.28.1.7 | DisplayString | read-only | mandatory |
| pmmDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.2 | |||
| pmmDeviceNominalInputVoltage OBJECT-TYPE The nominal input voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. | 1.3.6.1.4.1.318.1.1.28.2.1 | INTEGER | read-only | mandatory |
| pmmDeviceServiceType OBJECT-TYPE The type of utility input to the PMM. Either 3 wires (delta), or 4 wires (wye). | 1.3.6.1.4.1.318.1.1.28.2.2 | INTEGER {threeWire(1), fourWire(2)} | read-only | mandatory |
| pmmDeviceNominalOutputVoltage OBJECT-TYPE The nominal line-to-neutral output voltage to the load measured in Volts. | 1.3.6.1.4.1.318.1.1.28.2.3 | INTEGER | read-only | mandatory |
| pmmMonitoring OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.3 | |||
| pmmInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.3.1 | |||
| pmmInputMeterTableSize OBJECT-TYPE The number of input meters attached to the system. | 1.3.6.1.4.1.318.1.1.28.3.1.1 | INTEGER | read-only | mandatory |
| pmmInputTable OBJECT-TYPE A list of input meter entries. | 1.3.6.1.4.1.318.1.1.28.3.1.2 | not-accessible | mandatory | |
| pmmInputEntry OBJECT-TYPE An entry containing information applicable to a particular input meter. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1 | not-accessible | mandatory | |
| pmmInputMeterIndex OBJECT-TYPE The input meter identifier. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.1 | INTEGER | read-only | mandatory |
| pmmInputFrequency OBJECT-TYPE The input frequency in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.2 | INTEGER | read-only | mandatory |
| pmmInputTotalActivePower OBJECT-TYPE Shows the total input active power in tenths of kW. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.3 | INTEGER | read-only | mandatory |
| pmmInputTotalApparentPower OBJECT-TYPE Shows the total input apparent power in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.4 | INTEGER | read-only | mandatory |
| pmmInputTotalPowerFactor OBJECT-TYPE Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.5 | INTEGER | read-only | mandatory |
| pmmInputActiveEnergyDelivered OBJECT-TYPE Shows the input active energy delivered in tenths of kWh. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.6 | Integer32 | read-only | mandatory |
| pmmInputActiveEnergyReceived OBJECT-TYPE Shows the input active energy received in tenths of kWh. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.7 | Integer32 | read-only | mandatory |
| pmmInputApparentEnergyDelivered OBJECT-TYPE Shows the input apparent energy delivered in tenths of kVAh. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.8 | Integer32 | read-only | mandatory |
| pmmInputApparentEnergyReceived OBJECT-TYPE Shows the input apparent energy received in tenths of kVAh. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.9 | Integer32 | read-only | mandatory |
| pmmInputFrequencyDeviation OBJECT-TYPE Shows the input frequency deviation in Hertz. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.10 | INTEGER {freqDeviationOff(1), freqDeviationPointTwo(2), freqDeviationPointFive(3), freqDeviationOne(4), freqDeviationOnePointFive(5), freqDeviationTwo(6), freqDeviationThree(7), freqDeviationFour(8), freqDeviationFive(9), freqDeviationNine(10)} | read-write | mandatory |
| pmmInputPowerFactorDeviation OBJECT-TYPE Shows the input power factor deviation. Specified in tenths. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.11 | INTEGER (0..100) | read-write | mandatory |
| pmmInputMinVoltThreshold OBJECT-TYPE Threshold below which an input minimum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.12 | INTEGER (0..100) | read-write | mandatory |
| pmmInputLowVoltThreshold OBJECT-TYPE Threshold below which an input low voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.13 | INTEGER (0..100) | read-write | mandatory |
| pmmInputHighVoltThreshold OBJECT-TYPE Threshold above which an input high voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.14 | INTEGER (0..120) | read-write | mandatory |
| pmmInputMaxVoltThreshold OBJECT-TYPE Threshold above which an input maximum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.15 | INTEGER (0..120) | read-write | mandatory |
| pmmInputMinCurrentThreshold OBJECT-TYPE Threshold below which an input minimum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.16 | INTEGER (0..100) | read-write | mandatory |
| pmmInputLowCurrentThreshold OBJECT-TYPE Threshold below which an input low current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.17 | INTEGER (0..100) | read-write | mandatory |
| pmmInputHighCurrentThreshold OBJECT-TYPE Threshold above which an input high current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.18 | INTEGER (0..110) | read-write | mandatory |
| pmmInputMaxCurrentThreshold OBJECT-TYPE Threshold above which an input maximum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.19 | INTEGER (0..100) | read-write | mandatory |
| pmmInputMinApparentPowerThreshold OBJECT-TYPE Threshold below which an input minimum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.20 | INTEGER (0..100) | read-write | mandatory |
| pmmInputMaxApparentPowerThreshold OBJECT-TYPE Threshold above which an input maximum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.21 | INTEGER (0..110) | read-write | mandatory |
| pmmInputOverActivePowerThreshold OBJECT-TYPE Threshold above which an input over active power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.22 | INTEGER (0..100) | read-write | mandatory |
| pmmInputBreakerState OBJECT-TYPE This value indicates the current state of input breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.23 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| pmmInputBreakerOpenAlarm OBJECT-TYPE Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.24 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-write | mandatory |
| pmmInputAverageCurrent OBJECT-TYPE Input Average current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.25 | INTEGER | read-only | mandatory |
| pmmInputNeturalCurrent OBJECT-TYPE Input Netural current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.26 | INTEGER | read-only | mandatory |
| pmmInputMaxInstantaneousNeutralCurrent OBJECT-TYPE Input maximum instantaneous neutral current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.27 | INTEGER | read-only | mandatory |
| pmmInputAverageCurrentTHD OBJECT-TYPE Input average harmonic distortions. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.28 | INTEGER | read-only | mandatory |
| pmmInputAverageVoltageLtoL OBJECT-TYPE Input Average Line to Line voltage. Measured in tenths of Volts. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.29 | INTEGER | read-only | mandatory |
| pmmInputAverageVoltageLtoN OBJECT-TYPE Input Average Line to Neutral voltage. Measured in tenths of Volts. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.30 | INTEGER | read-only | mandatory |
| pmmInputLoad OBJECT-TYPE Total load of input breaker in percentage. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.31 | INTEGER | read-only | mandatory |
| pmmInputMeterFirmwareVersion OBJECT-TYPE Shows the input meter firmware revision. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.32 | INTEGER | read-only | mandatory |
| pmmInputMeterSerialNumber OBJECT-TYPE Shows the input meter serial number. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.33 | DisplayString | read-only | mandatory |
| pmmInputEnergyUsageAccumulatedTotal OBJECT-TYPE Shows the total accumulated input energy usage in kwh. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.34 | INTEGER | read-only | mandatory |
| pmmInputPhaseLoss OBJECT-TYPE Threshold below which an input phase loss condition will be generated. Specified as a percent deviation from phase to neutral nominal voltage. A value of zero indicates that the threshold is disabled. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.35 | INTEGER | read-only | mandatory |
| pmmInputBreakerCTSize OBJECT-TYPE Shows the input breaker CT size. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.36 | INTEGER | read-only | mandatory |
| pmmInputBreakerRating OBJECT-TYPE Shows the input breaker rating in Amps(A). Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.37 | INTEGER | read-only | mandatory |
| pmmInputKWHResetDate OBJECT-TYPE The date that the kWh usage was reset, in the format mm/dd/yyyy. | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.38 | DisplayString | read-only | mandatory |
| pmmInputAlarmGeneration OBJECT-TYPE Alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.39 | INTEGER | read-only | mandatory |
| pmmInputVoltageMaximumAlarm OBJECT-TYPE Voltage maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.40 | INTEGER | read-only | mandatory |
| pmmInputVoltageHighAlarm OBJECT-TYPE Voltage high alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.41 | INTEGER | read-only | mandatory |
| pmmInputVoltageLowAlarm OBJECT-TYPE Voltage low alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.42 | INTEGER | read-only | mandatory |
| pmmInputVoltageMinimumAlarm OBJECT-TYPE Voltage minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.43 | INTEGER | read-only | mandatory |
| pmmInputCurrentMaximumAlarm OBJECT-TYPE Current maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.44 | INTEGER | read-only | mandatory |
| pmmInputCurrentHighAlarm OBJECT-TYPE Current high alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.45 | INTEGER | read-only | mandatory |
| pmmInputCurrentLowAlarm OBJECT-TYPE Current low alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.46 | INTEGER | read-only | mandatory |
| pmmInputCurrentMinimumAlarm OBJECT-TYPE Current minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.47 | INTEGER | read-only | mandatory |
| pmmInputApparentPowerMaximumAlarm OBJECT-TYPE Apparent Power maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.48 | INTEGER | read-only | mandatory |
| pmmInputApparentPowerMinimumAlarm OBJECT-TYPE Apparent Power minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.49 | INTEGER | read-only | mandatory |
| pmmInputKWOverAlarm OBJECT-TYPE Over active power alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.50 | INTEGER | read-only | mandatory |
| pmmInputPhaseLossAlarm OBJECT-TYPE Phase loss alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.51 | INTEGER | read-only | mandatory |
| pmmInputPowerFactorTotalAlarm OBJECT-TYPE Total power factor alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.52 | INTEGER | read-only | mandatory |
| pmmInputFrequencyDeviationAlarm OBJECT-TYPE Frequency deviation alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.1.2.1.53 | INTEGER | read-only | mandatory |
| pmmInputPhaseTable OBJECT-TYPE A list of input table entries. The number of entries is given by the value of pmmInputMeterTableSize OID. | 1.3.6.1.4.1.318.1.1.28.3.1.3 | not-accessible | mandatory | |
| pmmInputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input phase. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1 | not-accessible | mandatory | |
| pmmInputMeterNum OBJECT-TYPE The input meter identifier. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.1 | INTEGER | read-only | mandatory |
| pmmInputPhase OBJECT-TYPE Input phase index. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.2 | INTEGER | read-only | mandatory |
| pmmInputVoltageLtoL OBJECT-TYPE Line-to-line input voltage available. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.3 | INTEGER | read-only | mandatory |
| pmmInputVoltageLtoN OBJECT-TYPE Line-to-neutral input voltage available. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.4 | INTEGER | read-only | mandatory |
| pmmInputPhaseCurrent OBJECT-TYPE Input current per phase. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.5 | INTEGER | read-only | mandatory |
| pmmInputActivePower OBJECT-TYPE Input power per phase. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.6 | INTEGER | read-only | mandatory |
| pmmInputApparentPower OBJECT-TYPE Input power per phase. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.7 | INTEGER | read-only | mandatory |
| pmmInputPowerFactor OBJECT-TYPE Indicates the power factor of the input per phase. A value of 100 representing a unity power factor (1.00). Specified in hundredths. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.8 | INTEGER | read-only | mandatory |
| pmmInputMaxInstantaneousCurrent OBJECT-TYPE Input maximum phase instantaneous current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.9 | INTEGER | read-only | mandatory |
| pmmInputPhaseAngle OBJECT-TYPE Current phase Angle. Measured in tenths of decimal | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.10 | INTEGER | read-only | mandatory |
| pmmInputTHDLtoL OBJECT-TYPE Input harmonic distortions line to line. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.11 | INTEGER | read-only | mandatory |
| pmmInputTHDLtoN OBJECT-TYPE Input harmonic distortions line to netural. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.12 | INTEGER | read-only | mandatory |
| pmmInputCurrentTHD OBJECT-TYPE Input harmonic distortions. Returns -1 if unsupported or failed. Specified in tenths. | 1.3.6.1.4.1.318.1.1.28.3.1.3.1.13 | INTEGER | read-only | mandatory |
| pmmOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.3.2 | |||
| pmmOutputMeterTableSize OBJECT-TYPE The number of output meters attached to the system. | 1.3.6.1.4.1.318.1.1.28.3.2.1 | INTEGER | read-only | mandatory |
| pmmOutputTable OBJECT-TYPE A list of output meter entries. | 1.3.6.1.4.1.318.1.1.28.3.2.2 | not-accessible | mandatory | |
| pmmOutputEntry OBJECT-TYPE An entry containing information applicable to a particular output meter. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1 | not-accessible | mandatory | |
| pmmOutputMeterIndex OBJECT-TYPE The output meter identifier. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.1 | INTEGER | read-only | mandatory |
| pmmOutputFrequency OBJECT-TYPE The output frequency in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.2 | INTEGER | read-only | mandatory |
| pmmOutputTotalActivePower OBJECT-TYPE Shows the total output active power in tenths of kW. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.3 | INTEGER | read-only | mandatory |
| pmmOutputTotalApparentPower OBJECT-TYPE Shows the total output apparent power in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.4 | INTEGER | read-only | mandatory |
| pmmOutputTotalPowerFactor OBJECT-TYPE Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.5 | INTEGER | read-only | mandatory |
| pmmOutputActiveEnergyDelivered OBJECT-TYPE Shows the output active energy delivered in tenths of kWh. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.6 | Integer32 | read-only | mandatory |
| pmmOutputActiveEnergyReceived OBJECT-TYPE Shows the output active energy received in tenths of kWh. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.7 | Integer32 | read-only | mandatory |
| pmmOutputApparentEnergyDelivered OBJECT-TYPE Shows the output apparent energy delivered in tenths of kVAh. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.8 | Integer32 | read-only | mandatory |
| pmmOutputApparentEnergyReceived OBJECT-TYPE Shows the output apparent energy received in tenths of kVAh. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.9 | Integer32 | read-only | mandatory |
| pmmOutputFrequencyDeviation OBJECT-TYPE Shows the output frequency deviation in Hertz. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.10 | INTEGER {freqDeviationOff(1), freqDeviationPointTwo(2), freqDeviationPointFive(3), freqDeviationOne(4), freqDeviationOnePointFive(5), freqDeviationTwo(6), freqDeviationThree(7), freqDeviationFour(8), freqDeviationFive(9), freqDeviationNine(10)} | read-write | mandatory |
| pmmOutputPowerFactorDeviation OBJECT-TYPE Shows the output power factor deviation. Specified in tenths. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.11 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputMinVoltThreshold OBJECT-TYPE Threshold below which an output minimum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.12 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputLowVoltThreshold OBJECT-TYPE Threshold below which an output low voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.13 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputHighVoltThreshold OBJECT-TYPE Threshold above which an output high voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.14 | INTEGER (0..120) | read-write | mandatory |
| pmmOutputMaxVoltThreshold OBJECT-TYPE Threshold above which an output maximum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.15 | INTEGER (0..120) | read-write | mandatory |
| pmmOutputMinCurrentThreshold OBJECT-TYPE Threshold below which an output minimum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.16 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputLowCurrentThreshold OBJECT-TYPE Threshold below which an output low current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.17 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputHighCurrentThreshold OBJECT-TYPE Threshold above which an output high current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.18 | INTEGER (0..110) | read-write | mandatory |
| pmmOutputMaxCurrentThreshold OBJECT-TYPE Threshold above which an output maximum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.19 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputMinApparentPowerThreshold OBJECT-TYPE Threshold below which an output minimum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.20 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputMaxApparentPowerThreshold OBJECT-TYPE Threshold above which an output maximum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.21 | INTEGER (0..110) | read-write | mandatory |
| pmmOutputOverActivePowerThreshold OBJECT-TYPE Threshold above which an output over active power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.22 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputPhaseLossThreshold OBJECT-TYPE Threshold below which an output phase loss condition will be generated. Specified as a percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.23 | INTEGER (0..100) | read-write | mandatory |
| pmmOutputBreakerState OBJECT-TYPE This value indicates the current state of output breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.24 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| pmmOutputBreakerOpenAlarm OBJECT-TYPE Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.2.2.1.25 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-write | mandatory |
| pmmOutputPhaseTable OBJECT-TYPE A list of output table entries. The number of entries is given by the value of pmmOutputMeterTableSize OID. | 1.3.6.1.4.1.318.1.1.28.3.2.3 | not-accessible | mandatory | |
| pmmOutputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular output phase. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1 | not-accessible | mandatory | |
| pmmOutputMeterNum OBJECT-TYPE The output meter identifier. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.1 | INTEGER | read-only | mandatory |
| pmmOutputPhase OBJECT-TYPE Output phase index. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.2 | INTEGER | read-only | mandatory |
| pmmOutputVoltageLtoL OBJECT-TYPE Line-to-line output voltage available. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.3 | INTEGER | read-only | mandatory |
| pmmOutputVoltageLtoN OBJECT-TYPE Line-to-neutral output voltage available. Measured in tenths of Volts. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.4 | INTEGER | read-only | mandatory |
| pmmOutputPhaseCurrent OBJECT-TYPE Load current per phase. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.5 | INTEGER | read-only | mandatory |
| pmmOutputActivePower OBJECT-TYPE Output power per phase. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.6 | INTEGER | read-only | mandatory |
| pmmOutputApparentPower OBJECT-TYPE Output power per phase. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.7 | INTEGER | read-only | mandatory |
| pmmOutputPowerFactor OBJECT-TYPE Indicates the power factor of the output per phase. A value of 100 representing a unity power factor (1.00). Specified in hundredths. | 1.3.6.1.4.1.318.1.1.28.3.2.3.1.8 | INTEGER | read-only | mandatory |
| pmmBranch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.3.3 | |||
| pmmnumofBranchMeters OBJECT-TYPE The number of branch meters attached to the system. | 1.3.6.1.4.1.318.1.1.28.3.3.1 | INTEGER | read-only | mandatory |
| pmmBranchBreakerTableSize OBJECT-TYPE The number of branch breaker entries. | 1.3.6.1.4.1.318.1.1.28.3.3.2 | INTEGER | read-only | mandatory |
| pmmBranchBreakerTable OBJECT-TYPE A list of branch breaker table entries. The number of entries is contained in the pmmBranchBreakerTableSize OID. | 1.3.6.1.4.1.318.1.1.28.3.3.3 | not-accessible | mandatory | |
| pmmBranchBreakerEntry OBJECT-TYPE An entry containing information applicable to a particular branch breaker (panel/circuit position). | 1.3.6.1.4.1.318.1.1.28.3.3.3.1 | not-accessible | mandatory | |
| pmmBranchCircuitMeterIndex OBJECT-TYPE Index of branch circuit meter in the table. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.1 | INTEGER | read-only | mandatory |
| pmmBranchCircuitIndex OBJECT-TYPE The branch circuit index. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.2 | INTEGER | read-only | mandatory |
| pmmBranchCircuitNumberOfPoles OBJECT-TYPE The number of poles. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.3 | INTEGER | read-only | mandatory |
| pmmBranchCircuitPhase OBJECT-TYPE The phase associated with branch circuit. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.4 | DisplayString | read-only | mandatory |
| pmmBranchCircuitBreakerIdentifier OBJECT-TYPE The branch circuit identifier. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.5 | DisplayString | read-only | mandatory |
| pmmBranchCircuitLoadIdentifier OBJECT-TYPE Identifies the name or location of the branch circuit load. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.6 | DisplayString | read-only | mandatory |
| pmmBranchCircuitCurrent OBJECT-TYPE The branch circuit current Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.7 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBreakerRating OBJECT-TYPE The rating of the branch circuit breaker in Amps. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.8 | INTEGER | read-only | mandatory |
| pmmBranchCircuitTotalActivePower OBJECT-TYPE Branch circuit total power. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.9 | INTEGER | read-only | mandatory |
| pmmBranchCircuitTotalApparentPower OBJECT-TYPE Branch circuit total apparent power. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.10 | INTEGER | read-only | mandatory |
| pmmBranchCircuitEnergyUsage OBJECT-TYPE Indicates the accumulated energy usage in tenths of kWh. Displayed as 0 when not available or no energy used. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.11 | Gauge | read-only | mandatory |
| pmmBranchCircuitEnergyUsageResetDate OBJECT-TYPE The date that the kWh usage was reset, in the format mm/dd/yyyy. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.12 | DisplayString | read-only | mandatory |
| pmmBranchCircuitTotalPowerFactor OBJECT-TYPE Indicates the total power factor of the branch circuit output. A value of 100 representing a unity power factor (1.00) Specified in hundredths. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.13 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBreakerState OBJECT-TYPE This value indicates the current state of branch circuit breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.14 | INTEGER {open(1), closed(2), unknown(3)} | read-only | mandatory |
| pmmBranchCircuitMinCurrentThreshold OBJECT-TYPE Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.15 | INTEGER (0..100) | read-write | mandatory |
| pmmBranchCircuitLowCurrentThreshold OBJECT-TYPE Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.16 | INTEGER (0..100) | read-write | mandatory |
| pmmBranchCircuitHighCurrentThreshold OBJECT-TYPE Threshold above which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.17 | INTEGER (0..100) | read-write | mandatory |
| pmmBranchCircuitMaxCurrentThreshold OBJECT-TYPE Threshold above which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.18 | INTEGER (0..100) | read-write | mandatory |
| pmmBranchCircuitMinApparentPowerThreshold OBJECT-TYPE Threshold below which a branch circuit minimum apparent power condition will be generated. Specified as a percent of the branch breaker apparent power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.19 | INTEGER (0..100) | read-write | mandatory |
| pmmBranchCircuitMaxApparentPowerThreshold OBJECT-TYPE Threshold above which a branch circuit maximum apparent power condition will be generated. Specified as a percent of the branch breaker apparent power rating. A value of zero indicates that the threshold is disabled. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.20 | INTEGER (0..100) | read-write | mandatory |
| pmmBranchCircuitAlaramGeneration OBJECT-TYPE Alarm generation status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.21 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-only | mandatory |
| pmmBranchCircuitBreakerOpenAlarm OBJECT-TYPE Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.22 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-write | mandatory |
| pmmBranchCircuitBreakerAverageCurrent OBJECT-TYPE Branch breaker current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.23 | INTEGER | read-only | mandatory |
| pmmBranchCircuitMaxInstantaneousCurrentPhase OBJECT-TYPE Branch circuit maximum instantaneous current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.24 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBreakerMaxInstantaneousAverageCurrent OBJECT-TYPE Branch breaker maximum instantaneous current. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.25 | INTEGER | read-only | mandatory |
| pmmBranchCircuitAngle OBJECT-TYPE Branch circuit phase angle. Measured in tenths of Decimal. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.26 | INTEGER | read-only | mandatory |
| pmmBranchCircuitActivePower OBJECT-TYPE Branch circuit Active power. Measured in tenths of kW. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.27 | INTEGER | read-only | mandatory |
| pmmBranchCircuitApparentPower OBJECT-TYPE Branch circuit apparent power. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.28 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBreakerEnergyTotalUsage OBJECT-TYPE Indicates the circuit Breaker total accumulated energy usage in tenths of kWh. Displayed as 0 when not available or no energy used. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.29 | Gauge | read-only | mandatory |
| pmmBranchCircuitPowerFactor OBJECT-TYPE Indicates the power factor of the branch circuit. A value of 100 representing a unity power factor (1.00) Specified in hundredths. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.30 | INTEGER | read-only | mandatory |
| pmmBranchCircuitTHD OBJECT-TYPE Branch circuit harmonic distortion. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.31 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBreakerTHD OBJECT-TYPE Branch Breaker harmonic distortion. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.32 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBreakerLoad OBJECT-TYPE Total load on the Breaker. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.33 | INTEGER | read-only | mandatory |
| pmmBranchCircuitBranchNumber OBJECT-TYPE The branch number. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.34 | INTEGER | read-only | mandatory |
| pmmBranchCircuitChannelCTSize OBJECT-TYPE The branch CT Size. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.35 | INTEGER | read-only | mandatory |
| pmmBranchcircuitCurrentMaxAlarm OBJECT-TYPE Current maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.36 | INTEGER | read-only | mandatory |
| pmmBranchcircuitCurrentHighAlarm OBJECT-TYPE Current high alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.37 | INTEGER | read-only | mandatory |
| pmmBranchcircuitCurrentLowAlarm OBJECT-TYPE Current low alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.38 | INTEGER | read-only | mandatory |
| pmmBranchcircuitCurrentMinAlarm OBJECT-TYPE Current minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.39 | INTEGER | read-only | mandatory |
| pmmBranchcircuitApparentPowerMaxAlarm OBJECT-TYPE Apparent power maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.40 | INTEGER | read-only | mandatory |
| pmmBranchcircuitApparentPowerMinAlarm OBJECT-TYPE Apparent power minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown | 1.3.6.1.4.1.318.1.1.28.3.3.3.1.41 | INTEGER | read-only | mandatory |
| pmmSiteConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.28.3.4 | |||
| pmmSiteConfigTableSize OBJECT-TYPE The number of site configuration set supported by system. | 1.3.6.1.4.1.318.1.1.28.3.4.1 | INTEGER | read-only | mandatory |
| pmmSiteConfigTable OBJECT-TYPE A list of PMM site configurable entries. | 1.3.6.1.4.1.318.1.1.28.3.4.2 | not-accessible | mandatory | |
| pmmSiteConfigEntry OBJECT-TYPE An entry containing information applicable to a particular site configuration. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1 | not-accessible | mandatory | |
| pmmSiteConfigIndex OBJECT-TYPE PMM site configuration identifier. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.1 | INTEGER | read-only | mandatory |
| pmmSiteConfigNominalPtoPVoltage OBJECT-TYPE The nominal input phase to phase voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.2 | INTEGER | read-only | mandatory |
| pmmSiteConfigNominalPtoNVoltage OBJECT-TYPE The nominal input phase to neutral voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.3 | INTEGER | read-only | mandatory |
| pmmSiteConfigNominalCurrent OBJECT-TYPE The nominal input current to the PMM. Measured in tenths of Amps. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.4 | INTEGER | read-only | mandatory |
| pmmSiteConfigNominalFrequency OBJECT-TYPE The nominal input frequency to the PMM. Measured in tenths of Hertz. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.5 | INTEGER | read-only | mandatory |
| pmmSiteConfigNominalApparentPower OBJECT-TYPE The nominal input apparent power to the PMM. Measured in tenths of kVA. | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.6 | INTEGER | read-only | mandatory |
| pmmSiteConfigServiceType OBJECT-TYPE The type of utility input to the PMM. Either 3 wires (delta), or 4 wires (wye). | 1.3.6.1.4.1.318.1.1.28.3.4.2.1.7 | INTEGER {threeWire(1), fourWire(2)} | read-only | mandatory |
| pmmSiteConfigNumberofPanel OBJECT-TYPE The number of panels present. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.4.3 | INTEGER | read-only | mandatory |
| pmmSiteConfigNumberofChannel OBJECT-TYPE The number of channels present. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.4.4 | INTEGER | read-only | mandatory |
| pmmSiteConfigNumberofsources OBJECT-TYPE The number of input sources present. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.4.5 | INTEGER | read-only | mandatory |
| pmmSiteConfigProductModelNumber OBJECT-TYPE A character string identifying the model number of the RPP. This value is set at the factory. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.4.6 | DisplayString | read-only | mandatory |
| pmmSiteConfigProductSerialNumber OBJECT-TYPE A character string identifying the serial number of the RPP. This value is set at the factory. Returns -1 if unsupported or failed. | 1.3.6.1.4.1.318.1.1.28.3.4.7 | DisplayString | read-only | mandatory |
| charger OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.29 | |||
| chargerIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.29.1 | |||
| chargerIdentModel OBJECT-TYPE A character string identifying the model name of the Charger. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.29.1.1 | DisplayString | read-only | mandatory |
| chargerBasicIdentName OBJECT-TYPE An 8 byte ID string identifying the Charger. This object can be set by the administrator. | 1.3.6.1.4.1.318.1.1.29.1.2 | DisplayString | read-write | mandatory |
| chargerIdentSerialNumber OBJECT-TYPE A character string identifying the serial number of the Charger. This value is set at the factory. | 1.3.6.1.4.1.318.1.1.29.1.3 | DisplayString | read-only | mandatory |
| chargerIdentModelType OBJECT-TYPE The detailed model information of the Charger. | 1.3.6.1.4.1.318.1.1.29.1.4 | DisplayString | read-only | mandatory |
| chargerInput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.29.2 | |||
| chargerInputPhaseTable OBJECT-TYPE A list of input table entries. The number of entries is given by the sum of the Charger input phases. | 1.3.6.1.4.1.318.1.1.29.2.1 | not-accessible | mandatory | |
| chargerInputPhaseEntry OBJECT-TYPE An entry containing information applicable to a particular input phase. | 1.3.6.1.4.1.318.1.1.29.2.1.1 | not-accessible | mandatory | |
| chargerInputPhaseTableIndex OBJECT-TYPE The input identifier. | 1.3.6.1.4.1.318.1.1.29.2.1.1.1 | INTEGER | read-only | mandatory |
| chargerInputPhaseVoltage OBJECT-TYPE The input voltage in VAC, or -1 if it's unsupported by this Charger. | 1.3.6.1.4.1.318.1.1.29.2.1.1.2 | INTEGER | read-only | mandatory |
| chargerInputPhaseMinVoltage OBJECT-TYPE The lowest input voltage to the Charger during the previous minute of operation, or -1 if it's unsupported by this Charger. | 1.3.6.1.4.1.318.1.1.29.2.1.1.3 | INTEGER | read-only | mandatory |
| chargerInputPhaseMaxVoltage OBJECT-TYPE The highest input voltage to the Charger during the previous minute of operation, or -1 if it's unsupported by this Charger. | 1.3.6.1.4.1.318.1.1.29.2.1.1.4 | INTEGER | read-only | mandatory |
| chargerInputPhaseCurrent OBJECT-TYPE The input current in 0.1 amperes, or -1 if it's unsupported by this Charger. | 1.3.6.1.4.1.318.1.1.29.2.1.1.5 | INTEGER | read-only | mandatory |
| chargerOutput OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.29.3 | |||
| chargerOutputStatus OBJECT-TYPE The current state of the Charger. If the Charger is unable to determine the state of the Charger this variable is set to unknown(1). | 1.3.6.1.4.1.318.1.1.29.3.1 | INTEGER {unknown(1), initialising(2), standby(3), onBattery(4), floatCharging(5), boostCharging(6), initialCharging(7)} | read-only | mandatory |
| chargerOutputVauxVoltage OBJECT-TYPE The Load output voltage, measured in VDC. | 1.3.6.1.4.1.318.1.1.29.3.2 | Gauge | read-only | mandatory |
| chargerOutputTotalCurrent OBJECT-TYPE The current in amperes drawn by the load on the Charger. | 1.3.6.1.4.1.318.1.1.29.3.3 | Gauge | read-only | mandatory |
| chargerOutputLoad OBJECT-TYPE The current Charger load expressed in percent of the total rated current of the charger. | 1.3.6.1.4.1.318.1.1.29.3.4 | Gauge | read-only | mandatory |
| ePDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.30 | |||
| ePDUDeviceStatusTableSize OBJECT-TYPE The total number of Easy PDUs | 1.3.6.1.4.1.318.1.1.30.1 | INTEGER | read-only | mandatory |
| ePDUDevice OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.30.2 | |||
| ePDUDeviceStatusTable OBJECT-TYPE A table of Easy PDU status information | 1.3.6.1.4.1.318.1.1.30.2.1 | not-accessible | mandatory | |
| ePDUDeviceStatusEntry OBJECT-TYPE Status information from the Easy PDU being queried | 1.3.6.1.4.1.318.1.1.30.2.1.1 | not-accessible | mandatory | |
| ePDUDeviceStatusIndex OBJECT-TYPE The index to the Easy PDU status table entry | 1.3.6.1.4.1.318.1.1.30.2.1.1.1 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusModule OBJECT-TYPE The user-defined Rack PDU numeric ID | 1.3.6.1.4.1.318.1.1.30.2.1.1.2 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusVersion OBJECT-TYPE The Easy PDU firmware and hardware version | 1.3.6.1.4.1.318.1.1.30.2.1.1.3 | DisplayString | read-only | mandatory |
| ePDUDeviceStatusModelNumber OBJECT-TYPE The Easy PDU model number | 1.3.6.1.4.1.318.1.1.30.2.1.1.4 | DisplayString | read-only | mandatory |
| ePDUDeviceStatusSerialNumber OBJECT-TYPE The Easy PDU serial number | 1.3.6.1.4.1.318.1.1.30.2.1.1.5 | DisplayString | read-only | mandatory |
| ePDUDeviceStatusNumPhases OBJECT-TYPE The number of phases present in the Easy PDU | 1.3.6.1.4.1.318.1.1.30.2.1.1.6 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusActivePower OBJECT-TYPE Indicates the PDU Active Power. Units:1 Watt. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.2.1.1.7 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusReactivePower OBJECT-TYPE Indicates the PDU Reactive Power. Units:1 Var. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.2.1.1.8 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusApparentPower OBJECT-TYPE Indicates the PDU Apparent Power. Units:1 VA. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.2.1.1.9 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusPowerFactor OBJECT-TYPE Indicates the PDU Power Factor. Units:0.1%. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.2.1.1.10 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusEnergy OBJECT-TYPE Indicates the PDU Energy. Units:1 Wh. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.2.1.1.11 | INTEGER | read-only | mandatory |
| ePDUDeviceStatusFrequency OBJECT-TYPE Indicates the PDU Frequency. Units:0.001 Hz. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.2.1.1.12 | INTEGER | read-only | mandatory |
| ePDUDeviceControlTable OBJECT-TYPE A table of Easy PDU control data | 1.3.6.1.4.1.318.1.1.30.2.2 | not-accessible | mandatory | |
| ePDUDeviceControlEntry OBJECT-TYPE Control data from Easy PDU being queried | 1.3.6.1.4.1.318.1.1.30.2.2.1 | not-accessible | mandatory | |
| ePDUDeviceControlIndex OBJECT-TYPE The index to the Easy PDU control table entry | 1.3.6.1.4.1.318.1.1.30.2.2.1.1 | INTEGER | read-only | mandatory |
| ePDUDeviceControlModule OBJECT-TYPE The user-defined Easy PDU numeric ID | 1.3.6.1.4.1.318.1.1.30.2.2.1.2 | INTEGER | read-only | mandatory |
| ePDUDeviceControlReboot OBJECT-TYPE Setting this OID to reboot (1) will cause the device reboot immediately. Getting this OID in models that support this feature will do nothing and return the noOperation(0) value. | 1.3.6.1.4.1.318.1.1.30.2.2.1.3 | INTEGER {noOperation(0), reboot(1)} | read-write | mandatory |
| ePDUDeviceControlEngeryReset OBJECT-TYPE Setting this OID to reboot (1) will cause the device reboot immediately. Getting this OID in models that support this feature will do nothing and return the noOperation(0) value. | 1.3.6.1.4.1.318.1.1.30.2.2.1.4 | INTEGER {noOperation(0), reset(1)} | read-write | mandatory |
| ePDUDeviceControlBeepAlarm OBJECT-TYPE User-defined Beep alarm, 1 for turn off Beep, 2 for turn on Beep. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.2.2.1.5 | INTEGER {off(1), on(2)} | read-write | mandatory |
| ePDUPhaseTableSize OBJECT-TYPE The number of connected Easy PDU phases | 1.3.6.1.4.1.318.1.1.30.3 | INTEGER | read-only | mandatory |
| ePDUPhase OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.30.4 | |||
| ePDUPhaseConfigTable OBJECT-TYPE A table of Easy PDU phase configuration data | 1.3.6.1.4.1.318.1.1.30.4.1 | not-accessible | mandatory | |
| ePDUPhaseConfigEntry OBJECT-TYPE Configuration data from currently queried Easy PDU phase | 1.3.6.1.4.1.318.1.1.30.4.1.1 | not-accessible | mandatory | |
| ePDUPhaseConfigIndex OBJECT-TYPE The index to the Easy PDU phase configuration table entry | 1.3.6.1.4.1.318.1.1.30.4.1.1.1 | INTEGER | read-only | mandatory |
| ePDUPhaseConfigModule OBJECT-TYPE The user-defined Easy PDU numeric ID | 1.3.6.1.4.1.318.1.1.30.4.1.1.2 | INTEGER | read-only | mandatory |
| ePDUPhaseConfigNumber OBJECT-TYPE The numeric phase ID | 1.3.6.1.4.1.318.1.1.30.4.1.1.3 | INTEGER | read-only | mandatory |
| ePDUPhaseConfigOverVoltageThreshold OBJECT-TYPE User-defined Phase Over Voltage alarm threshold. Units:0.1 V. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.4.1.1.4 | INTEGER | read-write | mandatory |
| ePDUPhaseConfigLowVoltageThreshold OBJECT-TYPE User-defined Phase Low Voltage alarm threshold. Units:0.1 V. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.4.1.1.5 | INTEGER | read-write | mandatory |
| ePDUPhaseConfigOverCurrentThreshold OBJECT-TYPE User-defined Phase Over Current alarm threshold. Units:0.01 A. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.4.1.1.6 | INTEGER | read-write | mandatory |
| ePDUPhaseConfigLowCurrentThreshold OBJECT-TYPE User-defined Phase Low Current alarm threshold. Units:0.01 A. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.4.1.1.7 | INTEGER | read-write | mandatory |
| ePDUPhaseStatusTable OBJECT-TYPE A table of Rack PDU phase status data | 1.3.6.1.4.1.318.1.1.30.4.2 | not-accessible | mandatory | |
| ePDUPhaseStatusEntry OBJECT-TYPE Status data from currently queried Easy PDU phase | 1.3.6.1.4.1.318.1.1.30.4.2.1 | not-accessible | mandatory | |
| ePDUPhaseStatusIndex OBJECT-TYPE The index to the Easy PDU phase configuration table entry | 1.3.6.1.4.1.318.1.1.30.4.2.1.1 | INTEGER (1..12) | read-only | mandatory |
| ePDUPhaseStatusModule OBJECT-TYPE The user-defined Easy PDU numeric ID | 1.3.6.1.4.1.318.1.1.30.4.2.1.2 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusNumber OBJECT-TYPE The numeric phase ID | 1.3.6.1.4.1.318.1.1.30.4.2.1.3 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusVoltage OBJECT-TYPE Indicates the Phase Voltage. Units:0.1 V | 1.3.6.1.4.1.318.1.1.30.4.2.1.4 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusCurrent OBJECT-TYPE Indicates the Phase Current. Units:0.01 A | 1.3.6.1.4.1.318.1.1.30.4.2.1.5 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusActivePower OBJECT-TYPE Indicates the Phase Active Power. Units:1 Watt | 1.3.6.1.4.1.318.1.1.30.4.2.1.6 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusReactivePower OBJECT-TYPE Indicates the Phase Reactive Power. Units:1 Var. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.4.2.1.7 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusApparentPower OBJECT-TYPE Indicates the Phase Apparent Power. Units:1 VA. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.4.2.1.8 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusPowerFactor OBJECT-TYPE Indicates the Phase Power Factor. Units:0.1% | 1.3.6.1.4.1.318.1.1.30.4.2.1.9 | INTEGER | read-only | mandatory |
| ePDUPhaseStatusEnergy OBJECT-TYPE Indicates the Phase Energy. Units:1 Wh | 1.3.6.1.4.1.318.1.1.30.4.2.1.10 | INTEGER | read-only | mandatory |
| ePDUOutletTableSize OBJECT-TYPE The number of switched outlets on connected Easy PDUs. | 1.3.6.1.4.1.318.1.1.30.5 | INTEGER | read-only | mandatory |
| ePDUOutlet OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.30.6 | |||
| ePDUOutletStatusTable OBJECT-TYPE The number of switched outlets on connected Rack PDUs | 1.3.6.1.4.1.318.1.1.30.6.1 | not-accessible | mandatory | |
| ePDUOutletStatusEntry OBJECT-TYPE Switched Outlet status from currently queried Easy PDU switched outlet | 1.3.6.1.4.1.318.1.1.30.6.1.1 | not-accessible | mandatory | |
| ePDUOutletStatusIndex OBJECT-TYPE The index to the Easy PDU switched outlet status information table entry. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.1.1.1 | INTEGER (1..128) | read-only | mandatory |
| ePDUOutletStatusModule OBJECT-TYPE The user-defined Easy PDU numeric ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.1.1.2 | INTEGER | read-only | mandatory |
| ePDUOutletStatusNumber OBJECT-TYPE The numeric switched outlet ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.1.1.3 | INTEGER | read-only | mandatory |
| ePDUOutletStatusState OBJECT-TYPE Indicates the present switch state of the Easy PDU switched outlet being queried. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.1.1.4 | INTEGER {off(1), on(2)} | read-only | mandatory |
| ePDUOutletControlTable OBJECT-TYPE A table of Easy PDU switched outlet control data | 1.3.6.1.4.1.318.1.1.30.6.2 | not-accessible | mandatory | |
| ePDUOutletControlEntry OBJECT-TYPE Control data for currently queried Easy PDU switched outlet | 1.3.6.1.4.1.318.1.1.30.6.2.1 | not-accessible | mandatory | |
| ePDUOutletControlIndex OBJECT-TYPE The index to the Easy PDU switched outlet configuration table entry. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.2.1.1 | INTEGER (1..128) | read-only | mandatory |
| ePDUOutletControlModule OBJECT-TYPE The user-defined Easy PDU numeric ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.2.1.2 | INTEGER | read-only | mandatory |
| ePDUOutletControlNumber OBJECT-TYPE The numeric switched outlet ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). | 1.3.6.1.4.1.318.1.1.30.6.2.1.3 | INTEGER | read-only | mandatory |
| ePDUOutletControlCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (3) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. | 1.3.6.1.4.1.318.1.1.30.6.2.1.4 | INTEGER {immediateOn(1), immediateOff(2), outletUnknown(3)} | read-write | mandatory |
| ePDUSensorTableSize OBJECT-TYPE The number of connected temperature-humidity sensors | 1.3.6.1.4.1.318.1.1.30.7 | INTEGER | read-only | mandatory |
| ePDUSensor OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.1.30.8 | |||
| ePDUSensorConfigTable OBJECT-TYPE A table of temperature-humidity sensor configuration data | 1.3.6.1.4.1.318.1.1.30.8.1 | not-accessible | mandatory | |
| ePDUSensorConfigEntry OBJECT-TYPE Configuration data from temperature-humidity sensor being queried | 1.3.6.1.4.1.318.1.1.30.8.1.1 | not-accessible | mandatory | |
| ePDUSensorConfigIndex OBJECT-TYPE The index to the temperature-humidity sensor configuration data table entry | 1.3.6.1.4.1.318.1.1.30.8.1.1.1 | INTEGER | read-only | mandatory |
| ePDUSensorConfigModule OBJECT-TYPE The user-defined Easy PDU numeric ID | 1.3.6.1.4.1.318.1.1.30.8.1.1.2 | INTEGER | read-only | mandatory |
| ePDUSensorConfigTempMaxThreshold OBJECT-TYPE User-defined Max Temperature alarm threshold. Units: 0.1 degrees Celsius. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.8.1.1.3 | INTEGER | read-write | mandatory |
| ePDUSensorConfigTempMinThreshold OBJECT-TYPE User-defined Min Temperature alarm threshold. Units: 0.1 degrees Celsius. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.8.1.1.4 | INTEGER | read-write | mandatory |
| ePDUSensorConfigHumidityMaxThreshold OBJECT-TYPE User-defined Max Humidity alarm threshold. Units: 0.1% relative humidity. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.8.1.1.5 | INTEGER | read-write | mandatory |
| ePDUSensorConfigHumidityMinThreshold OBJECT-TYPE User-defined Min Humidity alarm threshold. Units: 0.1% relative humidity. Models that do not support this feature will respond to this OID with a value of -1. | 1.3.6.1.4.1.318.1.1.30.8.1.1.6 | INTEGER | read-write | mandatory |
| ePDUSensorStatusTable OBJECT-TYPE A table of temperature-humidity sensor status data | 1.3.6.1.4.1.318.1.1.30.8.2 | not-accessible | mandatory | |
| ePDUSensorStatusEntry OBJECT-TYPE Status information from temperature-humidity sensor being queried | 1.3.6.1.4.1.318.1.1.30.8.2.1 | not-accessible | mandatory | |
| ePDUSensorStatusIndex OBJECT-TYPE The index to the temperature-humidity status data table entry | 1.3.6.1.4.1.318.1.1.30.8.2.1.1 | INTEGER (1..4) | read-only | mandatory |
| ePDUSensorStatusModule OBJECT-TYPE The user-defined Easy PDU numeric ID | 1.3.6.1.4.1.318.1.1.30.8.2.1.2 | INTEGER | read-only | mandatory |
| ePDUSensorStatusTemperature OBJECT-TYPE Sensor temperature reading in tenths of degrees Celsius. | 1.3.6.1.4.1.318.1.1.30.8.2.1.3 | INTEGER | read-only | mandatory |
| ePDUSensorStatusHumidity OBJECT-TYPE Sensor humidity reading in 0.1 percent relative humidity. | 1.3.6.1.4.1.318.1.1.30.8.2.1.4 | INTEGER | read-only | mandatory |
| software OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2 | |||
| powerNetSubAgent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.1 | |||
| powerNetSoftwareSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.1.1 | |||
| powerNetSoftwareSystemDescription OBJECT-TYPE A brief description of the PowerNet sub-agent. | 1.3.6.1.4.1.318.1.2.1.1.1 | DisplayString (SIZE(0..79)) | read-only | mandatory |
| powerNetSoftwareOid OBJECT-TYPE The object identifier of the PowerNet sub-agent. | 1.3.6.1.4.1.318.1.2.1.1.2 | OBJECT IDENTIFIER | read-only | mandatory |
| powerNetSoftwareSystemUpTime OBJECT-TYPE The time that the sub-agent has been running. | 1.3.6.1.4.1.318.1.2.1.1.3 | TimeTicks | read-only | mandatory |
| powerNetSoftwareConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.1.2 | |||
| powerNetSoftwareTableSize OBJECT-TYPE The number of software modules supporting the UPS. | 1.3.6.1.4.1.318.1.2.1.2.1 | INTEGER | read-only | mandatory |
| powerNetSoftwareTable OBJECT-TYPE A list of the software monitoring the UPS. | 1.3.6.1.4.1.318.1.2.1.2.2 | not-accessible | mandatory | |
| powerNetSoftwareEntry OBJECT-TYPE An entry containing information on a software module. | 1.3.6.1.4.1.318.1.2.1.2.2.1 | not-accessible | mandatory | |
| moduleNumber OBJECT-TYPE The index into the Software Entry Table | 1.3.6.1.4.1.318.1.2.1.2.2.1.1 | INTEGER | read-only | mandatory |
| moduleName OBJECT-TYPE The name of the software module. | 1.3.6.1.4.1.318.1.2.1.2.2.1.2 | DisplayString (SIZE(0..79)) | read-only | mandatory |
| moduleVersion OBJECT-TYPE The version of the software module. | 1.3.6.1.4.1.318.1.2.1.2.2.1.3 | DisplayString (SIZE(0..8)) | read-only | mandatory |
| moduleDate OBJECT-TYPE The date of the software module represented as mm-dd-yy. | 1.3.6.1.4.1.318.1.2.1.2.2.1.4 | DisplayString (SIZE(0..9)) | read-only | mandatory |
| struxureWareOperations OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.2 | |||
| struxureWareOperationsStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.2.1 | |||
| serverStatus OBJECT-TYPE The status of the StruxureWare Operations server: 1: The status of the application server is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Restart the StruxureWare DC Operation server. If the server was part of a cluster, see the StruxureWare DC Operation User Assistance about rejoining the cluster. If the problem persists, contact Technical Support. 3: No problem. 4: High availability is lost. The StruxureWare DC Operation Application server is running but one or more nodes are not available. If the StruxureWare DC Operation server is part of a cluster, ensure all nodes are running and there is a network connection between the nodes. If the problem persists, contact Technical Support. 5: Wait for the StruxureWare DC Operation Application server to initialize. If the problem persists, contact Technical Support. 6: Wait for the StruxureWare DC Operation Application server to finish starting. If the problem persists, contact Technical Support. 7: This node is running in Disaster Recovery mode. 8: The JBoss postoffice is currently inconsistent. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support. 9: The JBoss is missing jgroups. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support. | 1.3.6.1.4.1.318.1.2.2.1.1 | INTEGER {unknown(1), stopped(2), running(3), running-missing(4), initializing(5), starting(6), disaster-recovery(7), postoffice-inconsistent(8), missing-jgroups(9)} | read-only | mandatory |
| databaseStatus OBJECT-TYPE The status of the StruxureWare Operations database: 1: The status of the database is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Restart the StruxureWare DC Operation server. If the server was part of a cluster, see the StruxureWare DC Operation User Assistance about rejoining the cluster. If the problem persists, contact Technical Support. 3: No problem. 4: High availability is lost. The database is detached from the cluster and does not receive updates. See the StruxureWare DC Operation User Assistance about reattaching the database node to the StruxureWare DC Operation cluster. If the problem persists, contact Technical Support. 5: The database is catching up with the cluster. Wait for the StruxureWare DC Operation database to retrieve all updates from the master node. If the problem persists, contact Technical Support. 6: The database is attaching to the cluster. Wait for the StruxureWare Operation database to attach to the cluster. If the problem persists, contact Technical Support. 7: The database is the master in a cluster. 8: The database is the primary slave in the cluster. All changes on master are synchronously replicated to this node. 9: The database is a secondary slave in the cluster. All changes on master are asynchronously replicated to this node. 10: The database does not replicate its changes to other nodes. | 1.3.6.1.4.1.318.1.2.2.1.2 | INTEGER {unknown(1), stopped(2), running(3), detached(4), catching-up(5), attaching(6), running-master(7), running-primary-slave(8), running-slave(9), running-alone(10)} | read-only | mandatory |
| loadBalancerStatus OBJECT-TYPE The status of the StruxureWare Operations load balancer: 1: Load Balancer status is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Load Balancer stopped. Restart the StruxureWare DC Operation server. If the problem persists, contact Technical Support. 3: Normal status 4: High availability is lost. The StruxureWare DC Operation Load Balancer is running but one or more nodes are not available. If the StruxureWare DC Operation server is part of a cluster, ensure all nodes are running and there is a network connection between the nodes. If the problem persists, contact Technical Support. | 1.3.6.1.4.1.318.1.2.2.1.3 | INTEGER {unknown(1), stopped(2), running(3), running-missing(4)} | read-only | mandatory |
| essentialServicesStatus OBJECT-TYPE The status of the StruxureWare Operations essential services: 1: Unknown status. Check Webmin and if the problem persists, contact Technical Support. 2: Essential services are not running on the StruxureWare DC Operation server. Reboot the node and monitor the status page in Webmin. If the problem persists, contact Technical Support. 3: Normal status 4: The time difference between the StruxureWare DC Operation slave and the master node is too big. Correct the time on the slave to match the time on the master. Consider using an NTP server. If the problem persists, contact Technical Support. 5: The last backup that was attempted on the StruxureWare DC Operation server has failed. Make certain that the system can write to the location specified as backup location. This is particularly relevant for network attached storage. If the problem persists, contact Technical Support. | 1.3.6.1.4.1.318.1.2.2.1.4 | INTEGER {unknown(1), stopped(2), running(3), time-sync-problems(4), backup-problems(5)} | read-only | mandatory |
| etlStatus OBJECT-TYPE The status of the StruxureWare Operations ETL services: 1: Unknown status. Check the network configuration and the server network settings. If the problem persists, contact Technical Support (http://www.apc.com/go/direct/index.cfm?tag=support). 2: Normal status, 3: ETL Transformations have failed and are subsequently stopped. Investigate the cause of the failure. If the problem persists, contact Technical Support (http://www.apc.com/go/direct/index.cfm?tag=support). 4: ETL Transformations are currently paused. 5: ETL Transformations are currently stopped. | 1.3.6.1.4.1.318.1.2.2.1.5 | INTEGER {unknown(1), running(2), failed(3), paused(4), stopped(5)} | read-only | mandatory |
| powerChuteNetworkShutdown OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3 | |||
| pcnsIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.1 | |||
| pcnshostname OBJECT-TYPE The hostname of the PCNS instance. | 1.3.6.1.4.1.318.1.2.3.1.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsVersion OBJECT-TYPE The version of PCNS installed. x.x.x | 1.3.6.1.4.1.318.1.2.3.1.2 | DisplayString (SIZE(0..9)) | read-only | mandatory |
| pcnsOS OBJECT-TYPE The version of OS PCNS is Installed on. | 1.3.6.1.4.1.318.1.2.3.1.3 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsJavaVersion OBJECT-TYPE The version of Java PCNS is running on. | 1.3.6.1.4.1.318.1.2.3.1.4 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsNetworking OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.2 | |||
| pcnsUIProtocol OBJECT-TYPE Web Protocol used to connect to the PCNS UI. | 1.3.6.1.4.1.318.1.2.3.2.1 | INTEGER {http(1), https(2)} | read-only | mandatory |
| pcnsHttpPort OBJECT-TYPE Port used for PCNS http UI. | 1.3.6.1.4.1.318.1.2.3.2.2 | INTEGER (0..65535) | read-only | mandatory |
| pcnsHttpsPort OBJECT-TYPE Port used for PCNS https UI. | 1.3.6.1.4.1.318.1.2.3.2.3 | INTEGER (0..65535) | read-only | mandatory |
| pcnsNetworkConfig OBJECT-TYPE Configuration of the TCP Network. | 1.3.6.1.4.1.318.1.2.3.2.4 | INTEGER {ipV4(1), ipV6(2)} | read-only | mandatory |
| pcnsVirtualInstall OBJECT-TYPE Virtualization technology in use by PCNS. | 1.3.6.1.4.1.318.1.2.3.2.5 | INTEGER {none(1), hyper-V(2), vmWare(3), nutanixAHV(4), nutanixESXi(5), simpliVity(6), hyperFlex(7)} | read-only | mandatory |
| pcnsNMC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.3 | |||
| pcnsMode OBJECT-TYPE Configuration mode of the UPS(s) which PCNS is monitoring. | 1.3.6.1.4.1.318.1.2.3.3.1 | INTEGER {single(1), redundant(2), parallel(3), advanced(4)} | read-only | mandatory |
| pcnsNMCPort OBJECT-TYPE Port used to connect to all of the Network Management Card(s). | 1.3.6.1.4.1.318.1.2.3.3.2 | INTEGER (0..65535) | read-only | mandatory |
| pcnsNMCProtocol OBJECT-TYPE Web Protocol used to connect to all of the Network Management Card(s). | 1.3.6.1.4.1.318.1.2.3.3.3 | INTEGER {http(1), https(2)} | read-only | mandatory |
| pcnsNmcTable OBJECT-TYPE The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown. | 1.3.6.1.4.1.318.1.2.3.3.4 | not-accessible | mandatory | |
| pcnsNmcEntry OBJECT-TYPE Details of the NMC. | 1.3.6.1.4.1.318.1.2.3.3.4.1 | not-accessible | mandatory | |
| pcnsNmcIndex OBJECT-TYPE Index of the NMC within PCNS setup. | 1.3.6.1.4.1.318.1.2.3.3.4.1.1 | Gauge | read-only | mandatory |
| pcnsNmcAddr OBJECT-TYPE The IP address of the NMC. | 1.3.6.1.4.1.318.1.2.3.3.4.1.2 | IpAddress | read-only | mandatory |
| pcnsNmcOutlet OBJECT-TYPE The Outlet Group which PCNS is enrolled with on the NMC. | 1.3.6.1.4.1.318.1.2.3.3.4.1.3 | Gauge | read-only | mandatory |
| pcnsEvents OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4 | |||
| pcnsPowerFailed OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.1 | |||
| pcnsPowerFailedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.1.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsPowerFailedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.1.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsPowerFailedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.1.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsPowerFailedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.1.4 | DisplayString | read-write | mandatory |
| pcnsPowerFailedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.1.5 | INTEGER | read-write | mandatory |
| pcnsPowerFailedEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.1.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsPowerFailedShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.1.7 | INTEGER | read-write | mandatory |
| pcnsPowerRestored OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.2 | |||
| pcnsPowerRestoredDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.2.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsPowerRestoredEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.2.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsPowerRestoredEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.2.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsPowerRestoredCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.2.4 | DisplayString | read-write | mandatory |
| pcnsPowerRestoredCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.2.5 | INTEGER | read-write | mandatory |
| pcnsOverload OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.3 | |||
| pcnsOverloadDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.3.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsOverloadEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.3.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsOverloadEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.3.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsOverloadCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.3.4 | DisplayString | read-write | mandatory |
| pcnsOverloadCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.3.5 | INTEGER | read-write | mandatory |
| pcnsOverloadEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.3.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsOverloadShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.3.7 | INTEGER | read-write | mandatory |
| pcnsOverloadSolved OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.4 | |||
| pcnsOverloadSolvedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.4.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsOverloadSolvedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.4.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsOverloadSolvedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.4.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsOverloadSolvedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.4.4 | DisplayString | read-write | mandatory |
| pcnsOverloadSolvedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.4.5 | INTEGER | read-write | mandatory |
| pcnsRunTimeExceeded OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.5 | |||
| pcnsRunTimeExceededDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.5.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsRunTimeExceededEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.5.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeExceededEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.5.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeExceededCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.5.4 | DisplayString | read-write | mandatory |
| pcnsRunTimeExceededCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.5.5 | INTEGER | read-write | mandatory |
| pcnsRunTimeExceededEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.5.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeExceededShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.5.7 | INTEGER | read-write | mandatory |
| pcnsRunTimeWithinRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.6 | |||
| pcnsRunTimeWithinRangeDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.6.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsRunTimeWithinRangeEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.6.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeWithinRangeEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.6.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeWithinRangeCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.6.4 | DisplayString | read-write | mandatory |
| pcnsRunTimeWithinRangeCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.6.5 | INTEGER | read-write | mandatory |
| pcnsRunTimeBelowThreshold OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.7 | |||
| pcnsRunTimeBelowThresholdDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.7.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnspcnsRunTimeBelowThresholdEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.7.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeBelowThresholdEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.7.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeBelowThresholdCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.7.4 | DisplayString | read-write | mandatory |
| pcnsRunTimeBelowThresholdEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.7.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeBelowThresholdCommandFileThreshold OBJECT-TYPE If the Runtime Remaining falls below this (seconds), the command file will run. | 1.3.6.1.4.1.318.1.2.3.4.7.8 | INTEGER | read-write | mandatory |
| pcnsRunTimeBelowThresholdShutdownThreshold OBJECT-TYPE If the Runtime Remaining falls below this (seconds), the shutdown will begin. | 1.3.6.1.4.1.318.1.2.3.4.7.9 | INTEGER | read-write | mandatory |
| pcnsRunTimeAboveThreshold OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.8 | |||
| pcnsRunTimeAboveThresholdDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.8.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsRunTimeAboveThresholdEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.8.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeAboveThresholdEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.8.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRunTimeAboveThresholdCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.8.4 | DisplayString | read-write | mandatory |
| pcnsRunTimeAboveThresholdCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.8.5 | INTEGER | read-write | mandatory |
| pcnsBatteryDischarged OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.10 | |||
| pcnsBatteryDischargedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.10.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBatteryDischargedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.10.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBatteryDischargedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.10.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBatteryDischargedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.10.4 | DisplayString | read-write | mandatory |
| pcnsBatteryDischargedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.10.5 | INTEGER | read-write | mandatory |
| pcnsBatteryDischargedEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.10.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBatteryDischargedShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.10.7 | INTEGER | read-write | mandatory |
| pcnsBatteryChargeInRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.11 | |||
| pcnsBatteryChargeInRangeDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.11.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBatteryChargeInRangeEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.11.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBatteryChargeInRangeEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.11.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBatteryChargeInRangeCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.11.4 | DisplayString | read-write | mandatory |
| pcnsBatteryChargeInRangeCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.11.5 | INTEGER | read-write | mandatory |
| pcnsFaultBypassEnabled OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.12 | |||
| pcnsFaultBypassEnabledDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.12.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsFaultBypassEnabledEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.12.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsFaultBypassEnabledEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.12.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsFaultBypassEnabledCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.12.4 | DisplayString | read-write | mandatory |
| pcnsFaultBypassEnabledCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.12.5 | INTEGER | read-write | mandatory |
| pcnsFaultBypassEnabledEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.12.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsFaultBypassEnabledShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.12.7 | INTEGER | read-write | mandatory |
| pcnsBypassEnabled OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.13 | |||
| pcnsBypassEnabledDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.13.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBypassEnabledEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.13.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassEnabledEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.13.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassEnabledCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.13.4 | DisplayString | read-write | mandatory |
| pcnsBypassEnabledCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.13.5 | INTEGER | read-write | mandatory |
| pcnsBypassEnabledEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.13.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassEnabledShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.13.7 | INTEGER | read-write | mandatory |
| pcnsBypassManualEnabled OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.14 | |||
| pcnsBypassManualEnabledDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.14.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBypassManualEnabledEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.14.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassManualEnabledEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.14.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassManualEnabledCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.14.4 | DisplayString | read-write | mandatory |
| pcnsBypassManualEnabledCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.14.5 | INTEGER | read-write | mandatory |
| pcnsBypassManualEnabledEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.14.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassManualEnabledShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.14.7 | INTEGER | read-write | mandatory |
| pcnsBypassDisabled OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.15 | |||
| pcnsBypassDisabledDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.15.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBypassDisabledEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.15.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassDisabledEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.15.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassDisabledCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.15.4 | DisplayString | read-write | mandatory |
| pcnsBypassDisabledCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.15.5 | INTEGER | read-write | mandatory |
| pcnsBypassContactorFailed OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.16 | |||
| pcnsBypassContactorFailedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.16.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBypassContactorFailedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.16.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassContactorFailedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.16.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassContactorFailedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.16.4 | DisplayString | read-write | mandatory |
| pcnsBypassContactorFailedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.16.5 | INTEGER | read-write | mandatory |
| pcnsBypassContactorFailedEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.16.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassContactorFailedShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.16.7 | INTEGER | read-write | mandatory |
| pcnsBypassContactorOk OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.17 | |||
| pcnsBypassContactorOkDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.17.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsBypassContactorOkEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.17.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassContactorOkEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.17.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsBypassContactorOkCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.17.4 | DisplayString | read-write | mandatory |
| pcnsBypassContactorOkCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.17.5 | INTEGER | read-write | mandatory |
| pcnsCommunicationLostOnBattery OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.18 | |||
| pcnsCommunicationLostOnBatteryDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.18.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsCommunicationLostOnBatteryEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.18.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationLostOnBatteryEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.18.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationLostOnBatteryCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.18.4 | DisplayString | read-write | mandatory |
| pcnsCommunicationLostOnBatteryCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.18.5 | INTEGER | read-write | mandatory |
| pcnsCommunicationLostOnBatteryEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.18.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationLostOnBatteryShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.18.7 | INTEGER | read-write | mandatory |
| pcnsCommunicationLost OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.19 | |||
| pcnsCommunicationLostDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.19.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsCommunicationLostEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.19.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationLostEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.19.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationLostCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.19.4 | DisplayString | read-write | mandatory |
| pcnsCommunicationLostCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.19.5 | INTEGER | read-write | mandatory |
| pcnsCommunicationLostEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.19.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationLostShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.19.7 | INTEGER | read-write | mandatory |
| pcnsNetCommunicationLost OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.20 | |||
| pcnsNetCommunicationLostDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.20.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsNetCommunicationLostEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.20.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsNetCommunicationLostEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.20.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsNetCommunicationLostCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.20.4 | DisplayString | read-write | mandatory |
| pcnsNetCommunicationLostCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.20.5 | INTEGER | read-write | mandatory |
| pcnsNetCommunicationLostEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.20.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsNetCommunicationLostShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.20.7 | INTEGER | read-write | mandatory |
| pcnsCommunicationEstablished OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.21 | |||
| pcnsCommunicationEstablishedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.21.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsCommunicationEstablishedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.21.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationEstablishedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.21.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsCommunicationEstablishedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.21.4 | DisplayString | read-write | mandatory |
| pcnsCommunicationEstablishedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.21.5 | INTEGER | read-write | mandatory |
| pcnsMinRedundancyLost OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.22 | |||
| pcnsMinRedundancyLostDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.22.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsMinRedundancyLostEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.22.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinRedundancyLostEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.22.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinRedundancyLostCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.22.4 | DisplayString | read-write | mandatory |
| pcnsMinRedundancyLostCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.22.5 | INTEGER | read-write | mandatory |
| pcnsMinRedundancyLostEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.22.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinRedundancyLostShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.22.7 | INTEGER | read-write | mandatory |
| pcnsMinRedundancyRegained OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.23 | |||
| pcnsMinRedundancyRegainedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.23.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsMinRedundancyRegainedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.23.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinRedundancyRegainedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.23.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinRedundancyRegainedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.23.4 | DisplayString | read-write | mandatory |
| pcnsMinRedundancyRegainedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.23.5 | INTEGER | read-write | mandatory |
| pcnsParallelRedundancyLost OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.24 | |||
| pcnsParallelRedundancyLostDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.24.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsParallelRedundancyLostEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.24.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsParallelRedundancyLostEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.24.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsParallelRedundancyLostCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.24.4 | DisplayString | read-write | mandatory |
| pcnsParallelRedundancyLostCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.24.5 | INTEGER | read-write | mandatory |
| pcnsParallelRedundancyLostEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.24.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsParallelRedundancyLostShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.24.7 | INTEGER | read-write | mandatory |
| pcnsParallelRedundancyRegained OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.25 | |||
| pcnsParallelRedundancyRegainedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.25.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsParallelRedundancyRegainedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.25.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsParallelRedundancyRegainedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.25.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsParallelRedundancyRegainedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.25.4 | DisplayString | read-write | mandatory |
| pcnsParallelRedundancyRegainedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.25.5 | INTEGER | read-write | mandatory |
| pcnsMaxInternalTempExceeded OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.26 | |||
| pcnsMaxInternalTempExceededDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.26.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsMaxInternalTempExceededEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.26.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMaxInternalTempExceededEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.26.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMaxInternalTempExceededCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.26.4 | DisplayString | read-write | mandatory |
| pcnsMaxInternalTempExceededCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.26.5 | INTEGER | read-write | mandatory |
| pcnsMaxInternalTempExceededEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.26.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMaxInternalTempExceededShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.26.7 | INTEGER | read-write | mandatory |
| pcnsMaxInternalTempInRange OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.27 | |||
| pcnsMaxInternalTempInRangeDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.27.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsMaxInternalTempInRangeEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.27.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMaxInternalTempInRangeEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.27.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMaxInternalTempInRangeCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.27.4 | DisplayString | read-write | mandatory |
| pcnsMaxInternalTempInRangeCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.27.5 | INTEGER | read-write | mandatory |
| pcnsMinLoadCapabilityLost OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.28 | |||
| pcnsMinLoadCapabilityLostDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.28.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsMinLoadCapabilityLostEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.28.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinLoadCapabilityLostEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.28.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinLoadCapabilityLostCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.28.4 | DisplayString | read-write | mandatory |
| pcnsMinLoadCapabilityLostCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.28.5 | INTEGER | read-write | mandatory |
| pcnsMinLoadCapabilityLostEnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.28.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinLoadCapabilityLostShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.28.7 | INTEGER | read-write | mandatory |
| pcnsMinLoadCapabilityRegained OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.29 | |||
| pcnsMinLoadCapabilityRegainedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.29.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsMinLoadCapabilityRegainedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.29.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinLoadCapabilityRegainedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.29.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsMinLoadCapabilityRegainedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.29.4 | DisplayString | read-write | mandatory |
| pcnsMinLoadCapabilityRegainedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.29.5 | INTEGER | read-write | mandatory |
| pcnsEnvironmentCommunicationEstablished OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.30 | |||
| pcnsEnvironmentCommunicationEstablishedDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.30.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsEnvironmentCommunicationEstablishedEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.30.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsEnvironmentCommunicationEstablishedEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.30.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsEnvironmentCommunicationEstablishedCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.30.4 | DisplayString | read-write | mandatory |
| pcnsEnvironmentCommunicationEstablishedCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.30.5 | INTEGER | read-write | mandatory |
| pcnsEnvironmentCommunicationLost OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.31 | |||
| pcnsEnvironmentCommunicationLostDesc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.31.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsEnvironmentCommunicationLostEnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.31.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsEnvironmentCommunicationLostEnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.31.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsEnvironmentCommunicationLostCommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.31.4 | DisplayString | read-write | mandatory |
| pcnsEnvironmentCommunicationLostCommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.31.5 | INTEGER | read-write | mandatory |
| pcnsTempInRangeProbe1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.32 | |||
| pcnsTempInRangeProbe1Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.32.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsTempInRangeProbe1EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.32.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempInRangeProbe1EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.32.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempInRangeProbe1CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.32.4 | DisplayString | read-write | mandatory |
| pcnsTempInRangeProbe1CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.32.5 | INTEGER | read-write | mandatory |
| pcnsTempOutOfRangeProbe1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.33 | |||
| pcnsTempOutOfRangeProbe1Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.33.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsTempOutOfRangeProbe1EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.33.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempOutOfRangeProbe1EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.33.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempOutOfRangeProbe1CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.33.4 | DisplayString | read-write | mandatory |
| pcnsTempOutOfRangeProbe1CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.33.5 | INTEGER | read-write | mandatory |
| pcnsTempOutOfRangeProbe1EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.33.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempOutOfRangeProbe1ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.33.7 | INTEGER | read-write | mandatory |
| pcnsHumidityInRangeProbe1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.34 | |||
| pcnsHumidityInRangeProbe1Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.34.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsHumidityInRangeProbe1EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.34.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityInRangeProbe1EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.34.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityInRangeProbe1CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.34.4 | DisplayString | read-write | mandatory |
| pcnsHumidityInRangeProbe1CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.34.5 | INTEGER | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.35 | |||
| pcnsHumidityOutOfRangeProbe1Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.35.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsHumidityOutOfRangeProbe1EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.35.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe1EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.35.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe1CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.35.4 | DisplayString | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe1CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.35.5 | INTEGER | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe1EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.35.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe1ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.35.7 | INTEGER | read-write | mandatory |
| pcnsTempInRangeProbe2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.36 | |||
| pcnsTempInRangeProbe2Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.36.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsTempInRangeProbe2EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.36.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempInRangeProbe2EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.36.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempInRangeProbe2CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.36.4 | DisplayString | read-write | mandatory |
| pcnsTempInRangeProbe2CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.36.5 | INTEGER | read-write | mandatory |
| pcnsTempOutOfRangeProbe2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.37 | |||
| pcnsTempOutOfRangeProbe2Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.37.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsTempOutOfRangeProbe2EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.37.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempOutOfRangeProbe2EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.37.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempOutOfRangeProbe2CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.37.4 | DisplayString | read-write | mandatory |
| pcnsTempOutOfRangeProbe2CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.37.5 | INTEGER | read-write | mandatory |
| pcnsTempOutOfRangeProbe2EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.37.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTempOutOfRangeProbe2ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.37.7 | INTEGER | read-write | mandatory |
| pcnsHumidityInRangeProbe2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.38 | |||
| pcnsHumidityInRangeProbe2Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.38.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsHumidityInRangeProbe2EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.38.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityInRangeProbe2EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.38.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityInRangeProbe2CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.38.4 | DisplayString | read-write | mandatory |
| pcnsHumidityInRangeProbe2CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.38.5 | INTEGER | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.39 | |||
| pcnsHumidityOutOfRangeProbe2Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.39.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsHumidityOutOfRangeProbe2EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.39.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe2EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.39.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe2CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.39.4 | DisplayString | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe2CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.39.5 | INTEGER | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe2EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.39.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsHumidityOutOfRangeProbe2ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.39.7 | INTEGER | read-write | mandatory |
| pcnsContactFault1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.40 | |||
| pcnsContactFault1Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.40.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactFault1EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.40.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault1EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.40.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault1CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.40.4 | DisplayString | read-write | mandatory |
| pcnsContactFault1CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.40.5 | INTEGER | read-write | mandatory |
| pcnsContactFault1EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.40.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault1ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.40.7 | INTEGER | read-write | mandatory |
| pcnsContactFault2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.41 | |||
| pcnsContactFault2Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.41.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactFault2EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.41.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault2EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.41.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault2CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.41.4 | DisplayString | read-write | mandatory |
| pcnsContactFault2CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.41.5 | INTEGER | read-write | mandatory |
| pcnsContactFault2EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.41.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault2ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.41.7 | INTEGER | read-write | mandatory |
| pcnsContactFault3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.42 | |||
| pcnsContactFault3Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.42.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactFault3EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.42.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault3EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.42.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault3CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.42.4 | DisplayString | read-write | mandatory |
| pcnsContactFault3CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.42.5 | INTEGER | read-write | mandatory |
| pcnsContactFault3EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.42.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault3ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.42.7 | INTEGER | read-write | mandatory |
| pcnsContactFault4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.43 | |||
| pcnsContactFault4Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.43.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactFault4EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.43.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault4EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.43.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault4CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.43.4 | DisplayString | read-write | mandatory |
| pcnsContactFault4CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.43.5 | INTEGER | read-write | mandatory |
| pcnsContactFault4EnableShutdown OBJECT-TYPE Perform a graceful shutdown of the server when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.43.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactFault4ShutdownDelay OBJECT-TYPE How long to wait after event occurs before performing a graceful shutdown of the server (seconds). | 1.3.6.1.4.1.318.1.2.3.4.43.7 | INTEGER | read-write | mandatory |
| pcnsContactNormal1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.44 | |||
| pcnsContactNormal1Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.44.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactNormal1EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.44.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal1EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.44.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal1CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.44.4 | DisplayString | read-write | mandatory |
| pcnsContactNormal1CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.44.5 | INTEGER | read-write | mandatory |
| pcnsContactNormal2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.45 | |||
| pcnsContactNormal2Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.45.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactNormal2EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.45.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal2EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.45.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal2CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.45.4 | DisplayString | read-write | mandatory |
| pcnsContactNormal2CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.45.5 | INTEGER | read-write | mandatory |
| pcnsContactNormal3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.46 | |||
| pcnsContactNormal3Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.46.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactNormal3EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.46.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal3EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.46.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal3CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.46.4 | DisplayString | read-write | mandatory |
| pcnsContactNormal3CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.46.5 | INTEGER | read-write | mandatory |
| pcnsContactNormal4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.4.47 | |||
| pcnsContactNormal4Desc OBJECT-TYPE The Description of the event. | 1.3.6.1.4.1.318.1.2.3.4.47.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcnsContactNormal4EnableLogging OBJECT-TYPE Log occurrences of this event in PCNS log. | 1.3.6.1.4.1.318.1.2.3.4.47.2 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal4EnableCommandFile OBJECT-TYPE Execute a command file when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.47.3 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsContactNormal4CommandFilePath OBJECT-TYPE Path of command file to execute when this event occurs. | 1.3.6.1.4.1.318.1.2.3.4.47.4 | DisplayString | read-write | mandatory |
| pcnsContactNormal4CommandFileDelay OBJECT-TYPE How long to wait after event occurs before executing command file (seconds). | 1.3.6.1.4.1.318.1.2.3.4.47.5 | INTEGER | read-write | mandatory |
| pcnsShutdown OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.5 | |||
| pcnsShutdownCommandFileEnabled OBJECT-TYPE Run a shutdown command file before performing graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.1 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsShutdownCommandFileDelay OBJECT-TYPE How long in seconds to wait before running a shutdown command file before graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.2 | INTEGER | read-write | mandatory |
| pcnsShutdownCommandFile OBJECT-TYPE Full name of the shutdown command file to run before graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.3 | DisplayString | read-write | mandatory |
| pcnsShutdownCommandFileDuration OBJECT-TYPE How long in seconds shutdown command file takes to run. | 1.3.6.1.4.1.318.1.2.3.5.4 | INTEGER | read-write | mandatory |
| pcnsTurnOffUps OBJECT-TYPE Turn off the UPS when performing a graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.5 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsTurnOffSOG OBJECT-TYPE Turn off the Outlet Group on the UPS when performing a graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.6 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsRuntimeRemainingThreshold OBJECT-TYPE This defines a threshold for runtime remaining. When the UPS is running on battery power and the runtime remaining on the UPS drops below the threshold, PowerChute will trigger a shutdown sequence. | 1.3.6.1.4.1.318.1.2.3.5.7 | INTEGER | read-write | mandatory |
| pcnsRuntimeRemainingCmdFileThreshold OBJECT-TYPE This defines a threshold for runtime remaining. When runtime remaining drops below this threshold, PowerChute will execute the command file. | 1.3.6.1.4.1.318.1.2.3.5.8 | INTEGER | read-write | mandatory |
| pcnsAdvancedShutdownTable OBJECT-TYPE The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown. | 1.3.6.1.4.1.318.1.2.3.5.9 | not-accessible | mandatory | |
| pcnsAdvancedShutdownEntry OBJECT-TYPE Details of the NMC. | 1.3.6.1.4.1.318.1.2.3.5.9.1 | not-accessible | mandatory | |
| pcnsAdvancedGroupNo OBJECT-TYPE Index of the Advanced Shutdown Group. | 1.3.6.1.4.1.318.1.2.3.5.9.1.1 | Gauge | read-only | mandatory |
| pcnsAdvancedGroupName OBJECT-TYPE Name of the Advanced Shutdown Group. | 1.3.6.1.4.1.318.1.2.3.5.9.1.2 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| pcnsAdvancedGroupNMC OBJECT-TYPE List of NMCs in the Advanced Shutdown Group. | 1.3.6.1.4.1.318.1.2.3.5.9.1.3 | DisplayString | read-only | mandatory |
| pcnsAdvancedShutdownUPSRequiredForLoad OBJECT-TYPE Number of UPS's required to power load. | 1.3.6.1.4.1.318.1.2.3.5.9.1.4 | INTEGER | read-write | mandatory |
| pcnsAdvancedShutdownCommandFileEnabled OBJECT-TYPE Run a shutdown command file before performing graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.9.1.5 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsAdvancedShutdownCommandFile OBJECT-TYPE Full name of the shutdown command file to run before graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.9.1.6 | DisplayString | read-write | mandatory |
| pcnsAdvancedShutdownCommandFileDuration OBJECT-TYPE How long in seconds shutdown command file takes to run. | 1.3.6.1.4.1.318.1.2.3.5.9.1.7 | INTEGER | read-write | mandatory |
| pcnsAdvancedShutdownPowerchuteServer OBJECT-TYPE Shut down PowerChute Server. | 1.3.6.1.4.1.318.1.2.3.5.9.1.8 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsAdvancedShutdownOnLostRedundancy OBJECT-TYPE Shut down if Redundancy lost. | 1.3.6.1.4.1.318.1.2.3.5.9.1.9 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsAdvancedTurnOffUps OBJECT-TYPE Turn off the UPS when performing a graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.9.1.10 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsAdvancedTurnOffSOG OBJECT-TYPE Turn off the Outlet Group on the UPS when performing a graceful shutdown. | 1.3.6.1.4.1.318.1.2.3.5.9.1.11 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| pcnsAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.3.6 | |||
| pcnsCriticalFlag OBJECT-TYPE PowerChute Network Shutdown has begun a safe shutdown of the host. | 1.3.6.1.4.1.318.1.2.3.6.1 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcnsCriticalCause OBJECT-TYPE The reason PowerChute Network Shutdown has begun a safe shutdown. | 1.3.6.1.4.1.318.1.2.3.6.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| pcnsNetComsLostFlag OBJECT-TYPE PowerChute cannot communicate with NMC. | 1.3.6.1.4.1.318.1.2.3.6.3 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcnsNMCComsLostFlag OBJECT-TYPE NMC cannot communicate with UPS. | 1.3.6.1.4.1.318.1.2.3.6.4 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcnsUpdateAvailableFlag OBJECT-TYPE PowerChute has detected that a newer version is available. | 1.3.6.1.4.1.318.1.2.3.6.5 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcnsUpdateDesc OBJECT-TYPE Details of the newer version of PowerChute. | 1.3.6.1.4.1.318.1.2.3.6.6 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| pcnsLoggingLevel OBJECT-TYPE Override the Root Logging level for PCNS. Possible Values: CLEAR, DEBUG | 1.3.6.1.4.1.318.1.2.3.7 | DisplayString (SIZE(0..6)) | read-write | mandatory |
| powerChuteBusinessEdition OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.4 | |||
| pcbeIdent OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.4.1 | |||
| pcbeHostname OBJECT-TYPE The hostname of the PCBE instance. | 1.3.6.1.4.1.318.1.2.4.1.1 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcbeVersion OBJECT-TYPE The version of PCBE installed. x.x.x | 1.3.6.1.4.1.318.1.2.4.1.2 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcbeOS OBJECT-TYPE The version of OS PCBE is installed on. | 1.3.6.1.4.1.318.1.2.4.1.3 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcbeJavaVersion OBJECT-TYPE The version of Java PCBE is running on. | 1.3.6.1.4.1.318.1.2.4.1.4 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| pcbeUIProtocol OBJECT-TYPE Web Protocol used to connect to the PCBE UI. | 1.3.6.1.4.1.318.1.2.4.1.5 | INTEGER {http(1), https(2)} | read-only | mandatory |
| pcbeHttpPort OBJECT-TYPE Port used for PCBE http UI. | 1.3.6.1.4.1.318.1.2.4.1.6 | INTEGER (0..65535) | read-only | mandatory |
| pcbeHttpsPort OBJECT-TYPE Port used for PCBE https UI. | 1.3.6.1.4.1.318.1.2.4.1.7 | INTEGER (0..65535) | read-only | mandatory |
| pcbeAlarms OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.2.4.6 | |||
| pcbeCriticalFlag OBJECT-TYPE PowerChute Business Edition has begun a safe shutdown of the host. | 1.3.6.1.4.1.318.1.2.4.6.1 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcbeCriticalCause OBJECT-TYPE The reason PowerChute Business Edition has begun a safe shutdown. | 1.3.6.1.4.1.318.1.2.4.6.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| pcbeComsLostFlag OBJECT-TYPE If active (1), PowerChute cannot communicate with UPS | 1.3.6.1.4.1.318.1.2.4.6.3 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcbeUpdateAvailableFlag OBJECT-TYPE PowerChute has detected that a newer version is available. | 1.3.6.1.4.1.318.1.2.4.6.5 | INTEGER {active(1), clear(2)} | read-only | mandatory |
| pcbeUpdateDesc OBJECT-TYPE Details of the newer version of PowerChute. | 1.3.6.1.4.1.318.1.2.4.6.6 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| system OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3 | |||
| backUPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.1 | |||
| smartUPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2 | |||
| smartUPS250 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.1 | |||
| smartUPS400 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.2 | |||
| smartUPS600 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.3 | |||
| smartUPS900 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.4 | |||
| smartUPS1250 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.5 | |||
| smartUPS2000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.6 | |||
| smartUPS450 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.7 | |||
| smartUPS700 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.8 | |||
| smartUPS1000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.9 | |||
| smartUPS1400 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.10 | |||
| smartUPS2200 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.11 | |||
| smartUPS3000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.12 | |||
| smartUPS5000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.13 | |||
| smartUPS7500 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.14 | |||
| smartUPS10000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.15 | |||
| smartUPS1500 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.16 | |||
| smartUPS3000DSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.17 | |||
| smartUPS5000DSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.18 | |||
| smartUPS8000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.2.19 | |||
| matrixUPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.3 | |||
| matrixUPS3000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.3.1 | |||
| matrixUPS5000 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.3.2 | |||
| masterSwitch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4 | |||
| masterSwitchV1 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.1 | |||
| masterSwitchV2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.2 | |||
| masterSwitchVM OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.3 | |||
| masterSwitchMSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.4 | |||
| masterSwitchrPDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.5 | |||
| masterSwitchrPDU2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.6 | |||
| masterSwitchsPDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.7 | |||
| masterSwitchrPDUB OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.8 | |||
| masterSwitchePDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.4.9 | |||
| symmetraUPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.5 | |||
| symmetraUPS4kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.5.1 | |||
| symmetraUPS8kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.5.2 | |||
| symmetraUPS12kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.5.3 | |||
| symmetraUPS16kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.5.4 | |||
| dp100E OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.6 | |||
| dp300E OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.7 | |||
| monitors OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.8 | |||
| environmental OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.8.1 | |||
| environmentalMgtSystem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.8.2 | |||
| emu2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.8.3 | |||
| mem OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.8.4 | |||
| redundantSwitch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.9 | |||
| dcPower OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.10 | |||
| dm3 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.10.1 | |||
| dcmim2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.10.2 | |||
| automaticXferSwitch OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.11 | |||
| netLock OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.12 | |||
| symmetra3PhaseUPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.13 | |||
| symmetra3PhaseUPS40kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.13.1 | |||
| symmetra3PhaseUPS60kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.13.2 | |||
| symmetra3PhaseUPS80kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.13.3 | |||
| symmetra3PhaseUPS20kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.13.4 | |||
| networkAir OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14 | |||
| airFMSeries OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.1 | |||
| rackAirRemovalUnit OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.2 | |||
| airPASeries OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.3 | |||
| airIRSC100Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.4 | |||
| airIRRC100Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.5 | |||
| airIRRP100Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.6 | |||
| airIRRP500Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.7 | |||
| airIRRD100Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.8 | |||
| airInRoomPerimeter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.9 | |||
| airACRC300Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.10 | |||
| airLESeries OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.11 | |||
| airIRRDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.12 | |||
| airEcoBreeze OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.13 | |||
| airLELSeries OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.14 | |||
| airACRC600Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.15 | |||
| airACRD600Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.16 | |||
| airEconomizer OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.17 | |||
| airTSAChillers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.18 | |||
| airLEG2Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.19 | |||
| airAmico OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.20 | |||
| airUniflarSP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.21 | |||
| airTrimChiller OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.22 | |||
| airACRD300Series OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.14.23 | |||
| infraStruXurePDU OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.15 | |||
| ais5000UPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16 | |||
| ais5000UPS10kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.1 | |||
| ais5000UPS20kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.2 | |||
| ais5000UPS30kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.3 | |||
| ais5000UPS40kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.4 | |||
| ais5000UPS60kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.5 | |||
| ais5000UPS80kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.6 | |||
| ais5000UPS100kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.16.7 | |||
| smartUPS3Phase OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.17 | |||
| smartUPS3Phase10kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.17.1 | |||
| smartUPS3Phase15kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.17.2 | |||
| smartUPS3Phase20kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.17.3 | |||
| smartUPS3Phase30kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.17.4 | |||
| smartUPS3Phase40kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.17.5 | |||
| battManager OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.18 | |||
| infraStruXureATS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.19 | |||
| conPortServ OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.20 | |||
| conPortServAP930x OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.20.1 | |||
| gutor OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21 | |||
| gutorPEW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.1 | |||
| gutorPDW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.2 | |||
| gutorWEW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.3 | |||
| gutorWDW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.4 | |||
| gutorSDC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.5 | |||
| gutorPXP OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.6 | |||
| gutorPXC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.21.7 | |||
| accControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.22 | |||
| accPX OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.22.1 | |||
| symmetraPX OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23 | |||
| symmetraPx48kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23.1 | |||
| symmetraPx160kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23.2 | |||
| symmetraPx250kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23.3 | |||
| symmetraPx500kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23.4 | |||
| symmetraPx100kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23.5 | |||
| symmetraPxDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.23.6 | |||
| isxModDistribution OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.24 | |||
| isx24ModuleHalfRackPdu OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.24.1 | |||
| isx6ModuleRackPdu OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.24.2 | |||
| isxServers OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.25 | |||
| isxcBasic OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.25.1 | |||
| isxcStandard OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.25.2 | |||
| isxcEnterprise OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.25.3 | |||
| isxcVirtual OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.25.4 | |||
| smartUPS2 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.27 | |||
| galaxy OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28 | |||
| galaxy7000UPS200kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.1 | |||
| galaxy7000UPS250kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.2 | |||
| galaxy7000UPS300kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.3 | |||
| galaxy7000UPS400kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.4 | |||
| galaxy7000UPS500kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.5 | |||
| galaxy7000SSC800kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.6 | |||
| galaxy7000SSC1200kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.7 | |||
| galaxy7000SSC2000kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.8 | |||
| galaxy300UPS10kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.9 | |||
| galaxy300UPS15kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.10 | |||
| galaxy300UPS20kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.11 | |||
| galaxy300UPS30kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.12 | |||
| galaxy300UPS40kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.13 | |||
| galaxy300UPS10kVA31 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.14 | |||
| galaxy300UPS15kVA31 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.15 | |||
| galaxy300UPS20kVA31 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.16 | |||
| galaxy300UPS30kVA31 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.17 | |||
| galaxy5000UPS20KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.18 | |||
| galaxy5000UPS30KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.19 | |||
| galaxy5000UPS40KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.20 | |||
| galaxy5000UPS50KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.21 | |||
| galaxy5000UPS60KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.22 | |||
| galaxy5000UPS80KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.23 | |||
| galaxy5000UPS100KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.24 | |||
| galaxy5000UPS120KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.25 | |||
| galaxy5000UPS130KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.26 | |||
| galaxy5500UPS20KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.27 | |||
| galaxy5500UPS30KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.28 | |||
| galaxy5500UPS40KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.29 | |||
| galaxy5500UPS50KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.30 | |||
| galaxy5500UPS60KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.31 | |||
| galaxy5500UPS80KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.32 | |||
| galaxy5500UPS100KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.33 | |||
| galaxy5500UPS120KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.34 | |||
| galaxy5500UPS130KVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.35 | |||
| galaxyVMUPS50kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.36 | |||
| galaxyVMUPS60kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.37 | |||
| galaxyVMUPS80kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.38 | |||
| galaxyVMUPS90kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.39 | |||
| galaxyVMUPS100kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.40 | |||
| galaxyVMUPS110kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.41 | |||
| galaxyVMUPS120kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.42 | |||
| galaxyVMUPS130kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.43 | |||
| galaxyVMUPS160kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.44 | |||
| galaxyVMUPS180kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.45 | |||
| galaxyVMUPS200kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.46 | |||
| galaxyVMUPS225kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.47 | |||
| galaxy9000UPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.48 | |||
| galaxy9000SSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.49 | |||
| galaxy9000UPSWithSSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.50 | |||
| galaxy9000FreqConverter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.51 | |||
| galaxyVXUPS625kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.56 | |||
| galaxyVXUPS750kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.57 | |||
| galaxyVXUPS1000kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.58 | |||
| galaxyVXUPS1250kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.59 | |||
| galaxyVXUPS1500kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.60 | |||
| galaxy300UPS60kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.61 | |||
| galaxy300UPS80kVA33 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.62 | |||
| galaxyVXUPS500kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.63 | |||
| galaxyVXUPS250kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.64 | |||
| galaxyVXUPS400kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.65 | |||
| galaxyVSUPS100kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.66 | |||
| galaxy7000UPS160kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.67 | |||
| galaxyVXUPS300kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.68 | |||
| galaxyVXUPS1100kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.69 | |||
| galaxyVSUPS10kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.70 | |||
| galaxyVSUPS15kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.71 | |||
| galaxyVSUPS20kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.72 | |||
| galaxyVSUPS25kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.73 | |||
| galaxyVSUPS30kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.74 | |||
| galaxyVSUPS40kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.75 | |||
| galaxyVSUPS50kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.76 | |||
| galaxyVSUPS60kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.77 | |||
| galaxyVSUPS75kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.78 | |||
| galaxyVSUPS80kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.79 | |||
| galaxyVSUPS120kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.80 | |||
| galaxyVSUPS150kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.81 | |||
| galaxyVXUPS800kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.82 | |||
| galaxyPXUPS60kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.83 | |||
| galaxyPXUPS80kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.84 | |||
| galaxyPXUPS100kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.85 | |||
| galaxyVLUPS500kW OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.28.86 | |||
| eps OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30 | |||
| eps6000UPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.1 | |||
| eps6000SSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.2 | |||
| eps6000UPSWithSSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.3 | |||
| eps6000FreqConverter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.4 | |||
| eps7000UPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.5 | |||
| eps7000SSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.6 | |||
| eps7000UPSWithSSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.7 | |||
| eps7000FreqConverter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.8 | |||
| eps8000UPS OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.9 | |||
| eps8000SSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.10 | |||
| eps8000UPSWithSSC OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.11 | |||
| eps8000FreqConverter OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.30.12 | |||
| pcns OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.31 | |||
| pcns4 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.31.1 | |||
| pcbe OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.33 | |||
| pcbe9 OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.33.1 | |||
| pmm OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.34 | |||
| pmm400kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.34.1 | |||
| pmm500kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.34.2 | |||
| rpp OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.35 | |||
| rpp400kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.35.1 | |||
| rpp250kVA OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.3.35.2 | |||
| experimental OBJECT-IDENTITY | 1.3.6.1.4.1.318.1.4 | |||
| apcmgmt OBJECT-IDENTITY | 1.3.6.1.4.1.318.2 | |||
| mconfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.1 | |||
| mconfigNumTrapReceivers OBJECT-TYPE The number of managers to send traps to. | 1.3.6.1.4.1.318.2.1.1 | INTEGER | read-only | mandatory |
| mconfigTrapReceiverTable OBJECT-TYPE A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers. | 1.3.6.1.4.1.318.2.1.2 | not-accessible | mandatory | |
| mconfigTrapReceiverEntry OBJECT-TYPE The managers to send traps to. | 1.3.6.1.4.1.318.2.1.2.1 | not-accessible | mandatory | |
| trapIndex OBJECT-TYPE The index to a trap receiver entry. | 1.3.6.1.4.1.318.2.1.2.1.1 | INTEGER | read-only | mandatory |
| receiverAddr OBJECT-TYPE The IP address of the manager to send a trap to. | 1.3.6.1.4.1.318.2.1.2.1.2 | IpAddress | read-write | mandatory |
| communityString OBJECT-TYPE The community name to use in the trap when sent to the manager. | 1.3.6.1.4.1.318.2.1.2.1.3 | DisplayString | read-write | mandatory |
| severity OBJECT-TYPE The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager. | 1.3.6.1.4.1.318.2.1.2.1.4 | INTEGER {information(1), warning(2), severe(3)} | read-only | obsolete |
| acceptThisReceiver OBJECT-TYPE The value of yes(1) indicates that trap generation for this manager is enabled. The value of no(2) indicates that trap generation for this manager is disabled | 1.3.6.1.4.1.318.2.1.2.1.5 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| receiveTrapType OBJECT-TYPE Type of trap. | 1.3.6.1.4.1.318.2.1.2.1.6 | INTEGER {powernet(1), ietf(2), both(3)} | read-only | obsolete |
| mconfigBOOTPEnabled OBJECT-TYPE The value of yes(1) indicates the PowerNet Adapter is configured to obtain its IP configuration parameters from a BOOTP server. The value of no(2) indicates adapter will assume IP configuration parameters values saved in adapter's eeprom, which was originally configured at local console. | 1.3.6.1.4.1.318.2.1.3 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| mconfigTFTPServerIP OBJECT-TYPE The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address is provided by BOOTP server and not allowed to be modified; otherwise, this IP address can be modified. Before using TFTP to load new code image, the image file should be placed in proper directory of the specified TFTP server. This OID is only supported by APC Network Management Cards. | 1.3.6.1.4.1.318.2.1.4 | IpAddress | read-write | mandatory |
| newCodeAuthentViaTFTP OBJECT-TYPE Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will start to load the remote image file, for authentication only, instead of saving the code into flash memory. Only if a validNewAgentCodeImage (1) is found will the agent reboot the PowerNet adapter and invoke the loader to load and save new code into the flash memory. Otherwise, the current agent code will continue to run. This OID shows the result of the above authentication process. validNewAgentCodeImage (1) means the code image on TFTP server is a valid APC agent code and is different version from the current agent. Once agent identifies this, loader will start to update flash memory with the new agent code. sameAgentCodeImage (2) means the code image on TFTP server is exactly the same as the currently running agent. Currently running agent will not invoke loader to load the same again. invalidAgentCodeImage (3) means the code image on TFTP server is NOT a valid APC agent code. Thus, current agent will not load it into the flash memory. The value of this OID will be associated with TRAP codeImageAuthentDone. This OID is only supported by APC Network Management Cards. | 1.3.6.1.4.1.318.2.1.5 | INTEGER {unknown(1), validNewAgentCodeImage(2), sameAgentCodeImage(3), invalidAgentCodeImage(4)} | read-only | mandatory |
| mconfigClock OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.1.6 | |||
| mconfigClockDate OBJECT-TYPE The current date in the mm/dd/yyyy format. Example: 01/01/2000. | 1.3.6.1.4.1.318.2.1.6.1 | DisplayString | read-write | mandatory |
| mconfigClockTime OBJECT-TYPE The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am. | 1.3.6.1.4.1.318.2.1.6.2 | DisplayString | read-write | mandatory |
| mcontrol OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.2 | |||
| mcontrolRestartAgent OBJECT-TYPE Setting this OID to restartCurrentAgent (1) will restart the same SNMP agent code currently saved in flash memory. Setting this OID to loadAndExecuteNewAgent (3) will enable adapter to load a new agent code into the flash memory and start to execute this new agent code. Bootp/tftp is the default protocol. loadAndExecuteNewAgent is only supported by APC Network Management Cards. Setting this OID to restartWithoutAgent (4) will restart the system and not start the agent. The subsequent time the system restarts the agent will also automatically restart. Setting this OID to resetNetworkAndRestart (5) will set the Boot Mode, IP Address, Subnet Mask, and Default Gateway to defaults, expire any existing DHCP lease and then restart the system. Setting this OID to resetNetworkLeaveModeAndRestart (6) will leave the Boot Mode at the current setting, set the IP Address, Subnet Mask, and Default Gateway to defaults, expire any existing DHCP lease and then restart the system. | 1.3.6.1.4.1.318.2.2.1 | INTEGER {restartCurrentAgent(1), continueCurrentAgent(2), loadAndExecuteNewAgent(3), restartWithoutAgent(4), resetNetworkAndRestart(5), resetNetworkLeaveModeAndRestart(6)} | read-write | mandatory |
| mtrapargs OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.3 | |||
| mtrapargsInteger OBJECT-TYPE This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.1 | INTEGER | read-only | mandatory |
| mtrapargsIpAddress OBJECT-TYPE This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0. | 1.3.6.1.4.1.318.2.3.2 | IpAddress | read-only | mandatory |
| mtrapargsString OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.3 | SnmpAdminString | read-only | mandatory |
| mtrapargsGauge OBJECT-TYPE This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.4 | Gauge | read-only | mandatory |
| mtrapargsTimeTicks OBJECT-TYPE This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.5 | TimeTicks | read-only | mandatory |
| mtrapargsInteger02 OBJECT-TYPE This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.6 | INTEGER | read-only | mandatory |
| mtrapargsInteger03 OBJECT-TYPE This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.7 | INTEGER | read-only | mandatory |
| mtrapargsIpAddress02 OBJECT-TYPE This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0. | 1.3.6.1.4.1.318.2.3.8 | IpAddress | read-only | mandatory |
| mtrapargsIpAddress03 OBJECT-TYPE This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0. | 1.3.6.1.4.1.318.2.3.9 | IpAddress | read-only | mandatory |
| mtrapargsString02 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.10 | SnmpAdminString | read-only | mandatory |
| mtrapargsString03 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.11 | SnmpAdminString | read-only | mandatory |
| mtrapargsGauge02 OBJECT-TYPE This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.12 | Gauge | read-only | mandatory |
| mtrapargsGauge03 OBJECT-TYPE This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.13 | Gauge | read-only | mandatory |
| mtrapargsTimeTicks02 OBJECT-TYPE This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.14 | TimeTicks | read-only | mandatory |
| mtrapargsTimeTicks03 OBJECT-TYPE This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.15 | TimeTicks | read-only | mandatory |
| mtrapargsString04 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.16 | DisplayString | read-only | mandatory |
| mtrapargsString05 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.17 | DisplayString | read-only | mandatory |
| mtrapargsInteger04 OBJECT-TYPE This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.18 | INTEGER | read-only | mandatory |
| mtrapargsInteger05 OBJECT-TYPE This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0. | 1.3.6.1.4.1.318.2.3.19 | INTEGER | read-only | mandatory |
| mtrapargsString06 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.20 | DisplayString | read-only | mandatory |
| mtrapargsString07 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.21 | DisplayString | read-only | mandatory |
| mtrapargsString08 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.22 | DisplayString | read-only | mandatory |
| mtrapargsOctetString OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.23 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString02 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.24 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString03 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.25 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString04 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.26 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString05 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.27 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString06 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.28 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString07 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.29 | OCTET STRING | read-only | mandatory |
| mtrapargsOctetString08 OBJECT-TYPE This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string. | 1.3.6.1.4.1.318.2.3.30 | OCTET STRING | read-only | mandatory |
| mfiletransfer OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4 | |||
| mfiletransferStatus OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4.1 | |||
| mfiletransferStatusLastTransferResult OBJECT-TYPE This OID has been deprecated. Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer a file transfer of mfiletransferConfigSettingsFilename will be attempted from either a TFTP or FTP server. This OID shows the last attempted file transfer result. lastFileTransferResultSuccessful (1) means the file transfer was successful. lastFileTransferResultNotAvailable (2) means that there have been no previous file transfers. lastFileTransferResultFailureUnknown (3) means that the last file transfer failed for an unknown reason. lastFileTransferResultFailureServerInaccessible (4) means that the TFTP or FTP server could not be found on the network. lastFileTransferResultFailureServerAccessDenied (5) means that the TFTP or FTP server denied access. lastFileTransferResultFailureFileNotFound (6) means that the file could not be located. lastFileTransferResultFailureFileTypeUnknown (7) means the file was examined, but the contents were unknown. lastFileTransferResultFailureFileCorrupt (8) means the transferred file was corrupt. | 1.3.6.1.4.1.318.2.4.1.1 | INTEGER {lastFileTransferResultSuccessful(1), lastFileTransferResultNotAvailable(2), lastFileTransferResultFailureUnknown(3), lastFileTransferResultFailureServerInaccessible(4), lastFileTransferResultFailureServerAccessDenied(5), lastFileTransferResultFailureFileNotFound(6), lastFileTransferResultFailureFileTypeUnknown(7), lastFileTransferResultFailureFileCorrupted(8)} | read-only | deprecated |
| mfiletransferConfig OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4.2 | |||
| mfiletransferConfigSettings OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4.2.1 | |||
| mfiletransferConfigSettingsFilename OBJECT-TYPE This OID has been deprecated. The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID. If the file to transfer exists in the default server directory then the path may be omitted. | 1.3.6.1.4.1.318.2.4.2.1.1 | DisplayString | read-write | deprecated |
| mfiletransferConfigTFTP OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4.2.2 | |||
| mfiletransferConfigTFTPServerAddress OBJECT-TYPE This OID has been deprecated. The IP Address in dotted decimal notation of the TFTP server involved in the file transfer. | 1.3.6.1.4.1.318.2.4.2.2.1 | DisplayString | read-write | deprecated |
| mfiletransferConfigFTP OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4.2.3 | |||
| mfiletransferConfigFTPServerAddress OBJECT-TYPE This OID has been deprecated. The IP Address in dotted decimal notation of the FTP server involved in the file transfer. | 1.3.6.1.4.1.318.2.4.2.3.1 | DisplayString | read-write | deprecated |
| mfiletransferConfigFTPServerUser OBJECT-TYPE This OID has been deprecated. The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress. | 1.3.6.1.4.1.318.2.4.2.3.2 | DisplayString | read-write | deprecated |
| mfiletransferConfigFTPServerPassword OBJECT-TYPE This OID has been deprecated. The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress. | 1.3.6.1.4.1.318.2.4.2.3.3 | DisplayString | read-write | deprecated |
| mfiletransferControl OBJECT-IDENTITY | 1.3.6.1.4.1.318.2.4.3 | |||
| mfiletransferControlInitiateFileTransfer OBJECT-TYPE This OID has been deprecated. Setting this OID to doNotInitiateFileTransfer (1) will do nothing. Setting this OID to initiateFileTransferDownloadViaTFTP (2) will attempt to transfer the file named in mfiletransferConfigSettingsFilename from the TFTP Server identified in mfiletransferConfigTFTPAddress. Setting this OID to initiateFileTransferDownloadViaFTP (3) will attempt to transfer the file named in mfiletransferConfigSettingsFilename from the FTP Server identified in mfiletransferConfigFTPAddress using mfiletransferConfigFTPUser and mfiletransferConfigFTPPassword for the FTP Server login process. | 1.3.6.1.4.1.318.2.4.3.1 | INTEGER {doNotInitiateFileTransfer(1), initiateFileTransferDownloadViaTFTP(2), initiateFileTransferDownloadViaFTP(3)} | read-write | deprecated |
Notifications
| Name | OID | Status |
|---|---|---|
| communicationLost NOTIFICATION-TYPE SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress. | 1.3.6.1.4.1.318.0.1 | |
| upsOverload NOTIFICATION-TYPE SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity. | 1.3.6.1.4.1.318.0.2 | |
| upsDiagnosticsFailed NOTIFICATION-TYPE SEVERE: The UPS failed its internal diagnostic self-test. | 1.3.6.1.4.1.318.0.3 | |
| upsDischarged NOTIFICATION-TYPE SEVERE: The UPS batteries are discharged; if utility power fails an immediate low battery condition will exist. Sufficient runtime for necessary action cannot be guaranteed. | 1.3.6.1.4.1.318.0.4 | |
| upsOnBattery NOTIFICATION-TYPE WARNING: The UPS has switched to battery backup power. | 1.3.6.1.4.1.318.0.5 | |
| smartBoostOn NOTIFICATION-TYPE WARNING: The UPS has enabled SmartBoost(TM). | 1.3.6.1.4.1.318.0.6 | |
| lowBattery NOTIFICATION-TYPE SEVERE: The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load. | 1.3.6.1.4.1.318.0.7 | |
| communicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communication with the UPS has been established. | 1.3.6.1.4.1.318.0.8 | |
| powerRestored NOTIFICATION-TYPE INFORMATIONAL: Utility power has been restored. | 1.3.6.1.4.1.318.0.9 | |
| upsDiagnosticsPassed NOTIFICATION-TYPE INFORMATIONAL: The UPS passed its internal self-test. | 1.3.6.1.4.1.318.0.10 | |
| returnFromLowBattery NOTIFICATION-TYPE INFORMATIONAL: The UPS has returned from a low battery condition. | 1.3.6.1.4.1.318.0.11 | |
| upsTurnedOff NOTIFICATION-TYPE WARNING: The UPS has been turned 'off' by the management station. | 1.3.6.1.4.1.318.0.12 | |
| upsSleeping NOTIFICATION-TYPE WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off. | 1.3.6.1.4.1.318.0.13 | |
| upsWokeUp NOTIFICATION-TYPE INFORMATION: The UPS has returned from 'sleep' mode. Power to the load has been restored. | 1.3.6.1.4.1.318.0.14 | |
| upsRebootStarted NOTIFICATION-TYPE WARNING: The UPS has started its reboot sequence. The UPS will reboot itself at this time. | 1.3.6.1.4.1.318.0.15 | |
| upsDipSwitchChanged NOTIFICATION-TYPE WARNING: The dip switch settings on the UPS have been changed, possibly altering UPS performance. | 1.3.6.1.4.1.318.0.16 | |
| upsBatteryNeedsReplacement NOTIFICATION-TYPE SEVERE: The batteries of the UPS need immediate replacement. | 1.3.6.1.4.1.318.0.17 | |
| contactFault NOTIFICATION-TYPE SEVERE: One of the contacts on the Environmental Monitor has changed from its default position. The first variable is the contact number that is faulted. | 1.3.6.1.4.1.318.0.18 | |
| contactFaultResolved NOTIFICATION-TYPE INFORMATIONAL: A fault on one of the Environmental Monitor contacts has been resolved. The first variable is the contact number that has been resolved. | 1.3.6.1.4.1.318.0.19 | |
| hardwareFailureBypass NOTIFICATION-TYPE SEVERE: UPS on bypass due to internal fault | 1.3.6.1.4.1.318.0.20 | |
| softwareBypass NOTIFICATION-TYPE WARNING: UPS on bypass - user set via software or panel | 1.3.6.1.4.1.318.0.21 | |
| switchedBypass NOTIFICATION-TYPE WARNING: UPS on bypass - initiated by user | 1.3.6.1.4.1.318.0.22 | |
| returnFromBypass NOTIFICATION-TYPE INFORMATIONAL: UPS has returned from bypass | 1.3.6.1.4.1.318.0.23 | |
| bypassPowerSupplyFailure NOTIFICATION-TYPE SEVERE: Base module bypass power supply needs repair | 1.3.6.1.4.1.318.0.24 | |
| baseFanFailure NOTIFICATION-TYPE SEVERE: Base module fan needs repair | 1.3.6.1.4.1.318.0.25 | |
| batteryPackCommLost NOTIFICATION-TYPE SEVERE: Check installation of external battery packs signal cable | 1.3.6.1.4.1.318.0.26 | |
| batteryPackCommEstablished NOTIFICATION-TYPE INFORMATIONAL: UPS is communicating with the external battery packs. | 1.3.6.1.4.1.318.0.27 | |
| calibrationStart NOTIFICATION-TYPE INFORMATIONAL: A battery calibration test has been initiated on the UPS. | 1.3.6.1.4.1.318.0.28 | |
| restartAgent NOTIFICATION-TYPE INFORMATIONAL: Agent restarting as commanded by manager. | 1.3.6.1.4.1.318.0.29 | |
| upsTurnedOn NOTIFICATION-TYPE INFORMATIONAL: A UPS is turned on. | 1.3.6.1.4.1.318.0.30 | |
| smartAvrReducing NOTIFICATION-TYPE WARNING: The UPS is reducing the line voltage via SmartTrim(TM). | 1.3.6.1.4.1.318.0.31 | |
| codeAuthenticationDone NOTIFICATION-TYPE INFORMATIONAL: Authentication on agent code image is done. | 1.3.6.1.4.1.318.0.32 | |
| upsOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The overload condition has been cleared. | 1.3.6.1.4.1.318.0.33 | |
| smartBoostOff NOTIFICATION-TYPE INFORMATIONAL: The UPS has returned from SmartBoost(TM). | 1.3.6.1.4.1.318.0.34 | |
| smartAvrReducingOff NOTIFICATION-TYPE INFORMATIONAL: The UPS has returned from SmartTrim(TM). | 1.3.6.1.4.1.318.0.35 | |
| upsBatteryReplaced NOTIFICATION-TYPE INFORMATIONAL: A bad battery fault has been cleared. | 1.3.6.1.4.1.318.0.36 | |
| calibrationEnd NOTIFICATION-TYPE INFORMATIONAL: The UPS has finished calibrating. | 1.3.6.1.4.1.318.0.37 | |
| dischargeCleared NOTIFICATION-TYPE INFORMATIONAL: A UPS discharge condition has been cleared. | 1.3.6.1.4.1.318.0.38 | |
| gracefulShutdown NOTIFICATION-TYPE INFORMATIONAL: A graceful shutdown has been initiated. | 1.3.6.1.4.1.318.0.39 | |
| outletOn NOTIFICATION-TYPE WARNING: The specified PDU outlet has turned on. If sPDUOutletControlIndex equals zero, then all outlets have turned on. | 1.3.6.1.4.1.318.0.41 | |
| outletOff NOTIFICATION-TYPE WARNING: The specified PDU outlet has turned off. If sPDUOutletControlIndex equals zero, then all outlets have turned off. | 1.3.6.1.4.1.318.0.42 | |
| outletReboot NOTIFICATION-TYPE WARNING: The specified PDU outlet has rebooted. If sPDUOutletControlIndex equals zero, then all outlets have rebooted. | 1.3.6.1.4.1.318.0.43 | |
| configChangeSNMP NOTIFICATION-TYPE WARNING: The SNMP configuration has been changed. | 1.3.6.1.4.1.318.0.44 | |
| configChangeOutlet NOTIFICATION-TYPE WARNING: The specified PDU outlet has changed configuration. If sPDUOutletConfigIndex equals zero, then the Master outlet has changed configuration. | 1.3.6.1.4.1.318.0.45 | |
| accessViolationConsole NOTIFICATION-TYPE WARNING: Someone has attempted to login via the console with the incorrect password. | 1.3.6.1.4.1.318.0.46 | |
| accessViolationHTTP NOTIFICATION-TYPE WARNING: Someone has attempted to login via HTTP with the incorrect password. | 1.3.6.1.4.1.318.0.47 | |
| passwordChange NOTIFICATION-TYPE WARNING: The password for the device has been changed. | 1.3.6.1.4.1.318.0.48 | |
| badVoltage NOTIFICATION-TYPE WARNING: The output voltage is not within acceptable range. | 1.3.6.1.4.1.318.0.49 | |
| badVoltageCleared NOTIFICATION-TYPE INFORMATIONAL: The output voltage has returned to an acceptable level. | 1.3.6.1.4.1.318.0.50 | |
| chargerFailure NOTIFICATION-TYPE WARNING: The battery charger has failed. | 1.3.6.1.4.1.318.0.51 | |
| chargerFailureCleared NOTIFICATION-TYPE INFORMATIONAL: The battery charger failure condition has been cleared. | 1.3.6.1.4.1.318.0.52 | |
| batteryOverTemperature NOTIFICATION-TYPE WARNING: The battery temperature threshold has been violated. | 1.3.6.1.4.1.318.0.53 | |
| batteryOverTemperatureCleared NOTIFICATION-TYPE INFORMATIONAL: The battery over temperature has been cleared. | 1.3.6.1.4.1.318.0.54 | |
| smartRelayFault NOTIFICATION-TYPE WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault. | 1.3.6.1.4.1.318.0.55 | |
| smartRelayFaultCleared NOTIFICATION-TYPE INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared. | 1.3.6.1.4.1.318.0.56 | |
| humidityThresholdViolation1 NOTIFICATION-TYPE SEVERE: Probe 1 humidity threshold violated. The first variable is the current humidity. | 1.3.6.1.4.1.318.0.57 | |
| humidityThresholdViolationCleared1 NOTIFICATION-TYPE INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1. | 1.3.6.1.4.1.318.0.58 | |
| temperatureThresholdViolation1 NOTIFICATION-TYPE SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1. The first variable is the current temperature. | 1.3.6.1.4.1.318.0.59 | |
| temperatureThresholdViolationCleared1 NOTIFICATION-TYPE INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1. | 1.3.6.1.4.1.318.0.60 | |
| humidityThresholdViolation2 NOTIFICATION-TYPE SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2. The first variable is the current humidity. | 1.3.6.1.4.1.318.0.61 | |
| humidityThresholdViolationCleared2 NOTIFICATION-TYPE INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2. | 1.3.6.1.4.1.318.0.62 | |
| temperatureThresholdViolation2 NOTIFICATION-TYPE SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2. The first variable is the current temperature. | 1.3.6.1.4.1.318.0.63 | |
| temperatureThresholdViolationCleared2 NOTIFICATION-TYPE INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2. | 1.3.6.1.4.1.318.0.64 | |
| mupsCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communication with the Environmental Monitor has been established. | 1.3.6.1.4.1.318.0.65 | |
| mupsCommunicationLost NOTIFICATION-TYPE SEVERE: Communication to the Environmental Monitor has been lost. Steps to reestablish communication are in progress. | 1.3.6.1.4.1.318.0.66 | |
| batteryIncrease NOTIFICATION-TYPE INFORMATIONAL: The number of batteries has increased. | 1.3.6.1.4.1.318.0.67 | |
| batteryDecrease NOTIFICATION-TYPE INFORMATIONAL: The number of batteries has decreased. | 1.3.6.1.4.1.318.0.68 | |
| powerModuleIncrease NOTIFICATION-TYPE INFORMATIONAL: The number of power modules has increased. | 1.3.6.1.4.1.318.0.69 | |
| powerModuleDecrease NOTIFICATION-TYPE INFORMATIONAL: The number of power modules has decreased. | 1.3.6.1.4.1.318.0.70 | |
| intelligenceModuleInserted NOTIFICATION-TYPE INFORMATIONAL: An intelligence module has been inserted. | 1.3.6.1.4.1.318.0.71 | |
| intelligenceModuleRemoved NOTIFICATION-TYPE INFORMATIONAL: An intelligence module has been removed. | 1.3.6.1.4.1.318.0.72 | |
| rintelligenceModuleInserted NOTIFICATION-TYPE INFORMATIONAL: A redundant intelligence module has been inserted. | 1.3.6.1.4.1.318.0.73 | |
| rintelligenceModuleRemoved NOTIFICATION-TYPE INFORMATIONAL: A redundant intelligence module has been removed. | 1.3.6.1.4.1.318.0.74 | |
| extBatteryFrameIncease NOTIFICATION-TYPE INFORMATIONAL: An external battery frame has been added. | 1.3.6.1.4.1.318.0.75 | |
| extBatteryFrameDecrease NOTIFICATION-TYPE INFORMATIONAL: An external battery frame has been removed. | 1.3.6.1.4.1.318.0.76 | |
| abnormalCondition NOTIFICATION-TYPE SEVERE: An abnormal condition has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.77 | |
| abnormalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: An abnormal condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.78 | |
| deviceStatusChange NOTIFICATION-TYPE INFORMATIONAL: The status of the device being monitored has changed. | 1.3.6.1.4.1.318.0.79 | |
| noBatteries NOTIFICATION-TYPE WARNING: The UPS has no batteries attached. | 1.3.6.1.4.1.318.0.80 | |
| noBatteriesCleared NOTIFICATION-TYPE INFORMATIONAL: The UPS's batteries have been attached. | 1.3.6.1.4.1.318.0.81 | |
| userAdded NOTIFICATION-TYPE INFORMATIONAL: A new user has been added. | 1.3.6.1.4.1.318.0.82 | |
| userDeleted NOTIFICATION-TYPE INFORMATIONAL: A user has been deleted. | 1.3.6.1.4.1.318.0.83 | |
| userModified NOTIFICATION-TYPE INFORMATIONAL: A user has been modified. | 1.3.6.1.4.1.318.0.84 | |
| msvmCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communications with the MasterSwitch VM has been established. | 1.3.6.1.4.1.318.0.85 | |
| msvmCommunicationLost NOTIFICATION-TYPE SEVERE: Communications with the MasterSwitch VM has been lost. | 1.3.6.1.4.1.318.0.86 | |
| msvmOverload NOTIFICATION-TYPE SEVERE: The MasterSwitch VM in an overload condition. | 1.3.6.1.4.1.318.0.87 | |
| msvmOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared. | 1.3.6.1.4.1.318.0.88 | |
| msvmOutletOn NOTIFICATION-TYPE INFORMATIONAL: An outlet on the MasterSwitch VM has turned on. | 1.3.6.1.4.1.318.0.89 | |
| msvmOutletOff NOTIFICATION-TYPE INFORMATIONAL: An outlet on the MasterSwitch VM has turned off. | 1.3.6.1.4.1.318.0.90 | |
| msvmDeviceConfigChange NOTIFICATION-TYPE INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM. | 1.3.6.1.4.1.318.0.91 | |
| msvmOutletConfigChange NOTIFICATION-TYPE INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM. | 1.3.6.1.4.1.318.0.92 | |
| msvmLowLoad NOTIFICATION-TYPE INFORMATIONAL: The MasterSwitch VM has violated the low load threshold. | 1.3.6.1.4.1.318.0.93 | |
| msvmLowLoadCleared NOTIFICATION-TYPE INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared. | 1.3.6.1.4.1.318.0.94 | |
| msvmNearOverload NOTIFICATION-TYPE SEVERE: The MasterSwitch VM is approaching an overload condition. | 1.3.6.1.4.1.318.0.95 | |
| msvmNearOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared. | 1.3.6.1.4.1.318.0.96 | |
| msvmPowerSupplyStatusChange NOTIFICATION-TYPE WARNING: The power supply status of the MasterSwitch VM has changed. | 1.3.6.1.4.1.318.0.97 | |
| mspCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communications with the MasterSwitch plus has been established. | 1.3.6.1.4.1.318.0.98 | |
| mspCommunicationLost NOTIFICATION-TYPE SEVERE: Communications with the MasterSwitch plus has been lost. | 1.3.6.1.4.1.318.0.99 | |
| mspOutletOn NOTIFICATION-TYPE INFORMATIONAL: An outlet on the MasterSwitch plus has turned on. | 1.3.6.1.4.1.318.0.100 | |
| mspOutletOff NOTIFICATION-TYPE INFORMATIONAL: An outlet on the MasterSwitch plus has turned off. | 1.3.6.1.4.1.318.0.101 | |
| mspDeviceConfigChange NOTIFICATION-TYPE INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus. | 1.3.6.1.4.1.318.0.102 | |
| mspOutletConfigChange NOTIFICATION-TYPE INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus. | 1.3.6.1.4.1.318.0.103 | |
| rsSourceSwitched NOTIFICATION-TYPE INFORMATIONAL: The Redundant Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the 32-character name of the current source. The third variable is an integer representing the transfer cause: 0=No Transfers Recorded, 1=Due to user action or preferred switching, 3=Due to line notch or spike, 5=Due to low line voltage, 7=Transfer due to high line voltage, 9=Transfer due to frequency out of range. The fourth variable is a character string listing the transfer cause. | 1.3.6.1.4.1.318.0.104 | |
| rsLostRedundancy NOTIFICATION-TYPE SEVERE: The Redundant Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second variable is the 32-character name of the source which is no longer available. | 1.3.6.1.4.1.318.0.105 | |
| rsRedundancyRestored NOTIFICATION-TYPE INFORMATIONAL: Redundancy has been restored to the Redundant Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=B. The second variable is the 32-character name of the source which has been restored. | 1.3.6.1.4.1.318.0.106 | |
| rsConfigChange NOTIFICATION-TYPE INFORMATIONAL: A configuration change has been made on a Redundant Switch. | 1.3.6.1.4.1.318.0.107 | |
| rsCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communications with the Redundant Switch has been established. | 1.3.6.1.4.1.318.0.108 | |
| rsCommunicationLost NOTIFICATION-TYPE SEVERE: Communications with the Redundant Switch has been lost. | 1.3.6.1.4.1.318.0.109 | |
| dcCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communications with the DC power plant has been established. | 1.3.6.1.4.1.318.0.110 | |
| dcCommunicationLost NOTIFICATION-TYPE SEVERE: Communications with the DC power plant has been lost. | 1.3.6.1.4.1.318.0.111 | |
| dcPINChanged NOTIFICATION-TYPE INFORMATIONAL: The active PIN on the DC controller has been changed. | 1.3.6.1.4.1.318.0.112 | |
| dcMajorAlarm NOTIFICATION-TYPE SEVERE: A Major alarm is active in the DC power plant. | 1.3.6.1.4.1.318.0.113 | |
| dcMajorAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Major alarm is no longer active in the DC power plant. | 1.3.6.1.4.1.318.0.114 | |
| dcMinorAlarm NOTIFICATION-TYPE WARNING: A Minor alarm is active in the DC power plant. | 1.3.6.1.4.1.318.0.115 | |
| dcMinorAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Minor alarm is no longer active in the DC power plant. | 1.3.6.1.4.1.318.0.116 | |
| dcOutputRelayOn NOTIFICATION-TYPE WARNING: An output relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the output relay number that has gone on. The second variable is the 16-character name of the output relay. | 1.3.6.1.4.1.318.0.117 | |
| dcOutputRelayOff NOTIFICATION-TYPE INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the output relay number that has gone off. The second variable is the 16-character name of the output relay. | 1.3.6.1.4.1.318.0.118 | |
| dcInputRelayOn NOTIFICATION-TYPE WARNING: An input relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the input relay number that has gone on. The second variable is the 16-character name of the input relay. | 1.3.6.1.4.1.318.0.119 | |
| dcInputRelayOff NOTIFICATION-TYPE INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the input relay number that has gone off. The second variable is the 16-character name of the input relay. | 1.3.6.1.4.1.318.0.120 | |
| logicPowerSuppliesIncreased NOTIFICATION-TYPE INFORMATIONAL: The number of system power supplies has increased. | 1.3.6.1.4.1.318.0.121 | |
| logicPowerSuppliesDecreased NOTIFICATION-TYPE INFORMATIONAL: The number of system power supplies has decreased. | 1.3.6.1.4.1.318.0.122 | |
| externalSwitchGearClosed NOTIFICATION-TYPE INFORMATIONAL: External Switch Gear closed. | 1.3.6.1.4.1.318.0.123 | |
| externalSwitchGearOpened NOTIFICATION-TYPE INFORMATIONAL: External Switch Gear opened. | 1.3.6.1.4.1.318.0.124 | |
| generalDeviceEvent NOTIFICATION-TYPE INFORMATIONAL: APC Device event. | 1.3.6.1.4.1.318.0.125 | |
| atsSourceSwitched NOTIFICATION-TYPE INFORMATIONAL: The Automatic Transfer Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the 32-character name of the current source. | 1.3.6.1.4.1.318.0.126 | |
| atsLostRedundancy NOTIFICATION-TYPE SEVERE: The Automatic Transfer Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second variable is the 32-character name of the source which is no longer available. | 1.3.6.1.4.1.318.0.127 | |
| atsRedundancyRestored NOTIFICATION-TYPE INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=B. The second variable is the 32-character name of the source which has been restored. | 1.3.6.1.4.1.318.0.128 | |
| atsConfigChange NOTIFICATION-TYPE INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch. The first variable is an integer representing the configuration setting which changed: 0=Transfer Voltage Range, 1=Sensitivity, 2=Preferred Source 3=Front Panel Lockout, 4=Current Limit, 5=Reset XA Processor, 6=Reset to defaults, 7=Product Name, 8=Nominal Voltage, 9=Nominal Line Frequency, 10=Narrow VRMS, 11=Medium VRMS, 12=Wide VRMS,13=Frequency Deviation, 14=ColdStart ATS, 15=Events Count Cleared, 16=Phase or Bank Threshold. | 1.3.6.1.4.1.318.0.129 | |
| atsCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communications with the Automatic Transfer Switch has been established. | 1.3.6.1.4.1.318.0.130 | |
| atsCommunicationLost NOTIFICATION-TYPE SEVERE: Communications with the Automatic Transfer Switch has been lost. | 1.3.6.1.4.1.318.0.131 | |
| atsOverCurrent NOTIFICATION-TYPE SEVERE: Output Current has exceeded threshold. This is same as atsOverload Trap for phase or total in case banked units | 1.3.6.1.4.1.318.0.132 | |
| atsOverCurrentCleared NOTIFICATION-TYPE INFORMATIONAL: Output Current has returned below threshold.This is same as atsOverloadCleared Trap for phase or total in case banked units | 1.3.6.1.4.1.318.0.133 | |
| atsPowerSupplyFailure NOTIFICATION-TYPE SEVERE: The Automatic Transfer Switch Power Supply has failed. The first variable is an integer representing the Power Supply which has failed: 0 = Source A 24V, 1 = 12V, 2 = 5V, 3 = Source B 24V. | 1.3.6.1.4.1.318.0.134 | |
| atsPowerSupplyFailureCleared NOTIFICATION-TYPE INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared. The first variable is an integer representing the Power Supply which has cleared: 0 = Source A 24V, 1 = 12V, 2 = 5V, 3 = Source B 24V. | 1.3.6.1.4.1.318.0.135 | |
| dcMainsFailAlarm NOTIFICATION-TYPE WARNING: A Mains Fail alarm is active in the DC power plant. | 1.3.6.1.4.1.318.0.136 | |
| dcMainsFailAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant. | 1.3.6.1.4.1.318.0.137 | |
| dcFanFailAlarm NOTIFICATION-TYPE WARNING: A Fan Fail alarm is active in the DC power plant. | 1.3.6.1.4.1.318.0.138 | |
| dcFanFailAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant. | 1.3.6.1.4.1.318.0.139 | |
| dcRectifierOvertempAlarm NOTIFICATION-TYPE WARNING: Rect. Overtemp alarm is active in the power plant. | 1.3.6.1.4.1.318.0.140 | |
| dcRectifierOvertempAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant. | 1.3.6.1.4.1.318.0.141 | |
| dcCurrentLimitAlarm NOTIFICATION-TYPE WARNING: A Current Limit alarm is active in the power plant. | 1.3.6.1.4.1.318.0.142 | |
| dcCurrentLimitAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Current Limit alarm is no longer active in the power plant. | 1.3.6.1.4.1.318.0.143 | |
| dcRectifierFailAlarm NOTIFICATION-TYPE WARNING: A Rect. Fail alarm is active in the power plant. | 1.3.6.1.4.1.318.0.144 | |
| dcRectifierFailAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant. | 1.3.6.1.4.1.318.0.145 | |
| dcMultRectFailAlarm NOTIFICATION-TYPE WARNING: Multiple Rect. Fail alarm is active in the powerplant. | 1.3.6.1.4.1.318.0.146 | |
| dcMultRectFailAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Multiple Rect Fail alarm is no longer active in the powerplant. | 1.3.6.1.4.1.318.0.147 | |
| dcBatteryBreakerAlarm NOTIFICATION-TYPE WARNING: Batt. Breaker alarm is active in the power plant. | 1.3.6.1.4.1.318.0.148 | |
| dcBatteryBreakerAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant. | 1.3.6.1.4.1.318.0.149 | |
| dcRectifierOVPAlarm NOTIFICATION-TYPE WARNING: A Rect. OVP alarm is active in the power plant. | 1.3.6.1.4.1.318.0.150 | |
| dcRectifierOVPAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant. | 1.3.6.1.4.1.318.0.151 | |
| dcLVDImminentAlarm NOTIFICATION-TYPE WARNING: A LVD Imminent alarm is active in the powerplant. | 1.3.6.1.4.1.318.0.152 | |
| dcLVDImminentAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant. | 1.3.6.1.4.1.318.0.153 | |
| dcFuseCBAlarm NOTIFICATION-TYPE WARNING: A Fuse/CB alarm is active in the DC power plant. | 1.3.6.1.4.1.318.0.154 | |
| dcFuseCBAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant. | 1.3.6.1.4.1.318.0.155 | |
| dcBatteryTestFail NOTIFICATION-TYPE WARNING: A Battery Test failed in the DC power plant. | 1.3.6.1.4.1.318.0.156 | |
| dcTemperatureAlarm NOTIFICATION-TYPE WARNING: A Temperature is active in the power plant. | 1.3.6.1.4.1.318.0.157 | |
| dcTemperatureAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Temperature alarm is no longer active in the power plant. | 1.3.6.1.4.1.318.0.158 | |
| dcHumidityAlarm NOTIFICATION-TYPE WARNING: A Humidity alarm is active in the DC power plant. | 1.3.6.1.4.1.318.0.159 | |
| dcHumidityAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant. | 1.3.6.1.4.1.318.0.160 | |
| dcBBCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Power plant bridging board communications established. | 1.3.6.1.4.1.318.0.161 | |
| dcBBCommunicationLost NOTIFICATION-TYPE SEVERE: Power plant bridging board communications lost. | 1.3.6.1.4.1.318.0.162 | |
| iemHighTempThresholdViolation NOTIFICATION-TYPE SEVERE: High temperature threshold violated on Integrated Environmental Monitor probe. The first variable is the current temperature. The second variable is the temperature scale. The third variable is the probe number. The fourth variable is the probe name. | 1.3.6.1.4.1.318.0.163 | |
| iemHighTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High temperature threshold violated on Integrated Environmental Monitor probe has been cleared. The first variable is the probe number. The second variable is the probe name. | 1.3.6.1.4.1.318.0.164 | |
| iemLowTempThresholdViolation NOTIFICATION-TYPE SEVERE: Low temperature threshold violated on integrated probe. The first variable is the current temperature. The second variable is the temperature scale. The third variable is the probe number. The fourth variable is the probe name. | 1.3.6.1.4.1.318.0.165 | |
| iemLowTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low temperature threshold violated on integrated probe has been cleared. The first variable is the probe number. The second variable is the probe name. | 1.3.6.1.4.1.318.0.166 | |
| iemHighHumidThresholdViolation NOTIFICATION-TYPE SEVERE: High humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third variable is the probe name. | 1.3.6.1.4.1.318.0.167 | |
| iemHighHumidThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name. | 1.3.6.1.4.1.318.0.168 | |
| iemLowHumidThresholdViolation NOTIFICATION-TYPE SEVERE: Low humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third variable is the probe name. | 1.3.6.1.4.1.318.0.169 | |
| iemLowHumidThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name. | 1.3.6.1.4.1.318.0.170 | |
| iemProbeDisconnected NOTIFICATION-TYPE WARNING: The temperature/humidity probe on the Integrated Environmental Monitor has been disconnected. This trap is generated when a probe that has been in communication with the Environmental Monitor has been disconnected or can no longer communicate. | 1.3.6.1.4.1.318.0.171 | |
| iemProbeConnected NOTIFICATION-TYPE INFORMATIONAL: The temperature/humidity probe on the Integrated Environmental Monitor has been connected. This trap is generated when the Environmental Monitor establishes communication with a probe that had previously not been connected. | 1.3.6.1.4.1.318.0.172 | |
| iemContactFault NOTIFICATION-TYPE SEVERE: There is a contact fault on the Integrated Environmental Monitor. The first argument is the number of the contact. The second argument is the name of the contact. | 1.3.6.1.4.1.318.0.173 | |
| iemContactFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The contact fault on the Integrated Environmental Monitor has been cleared. The first argument is the number of the contact. The second argument is the name of the contact. | 1.3.6.1.4.1.318.0.174 | |
| iemRelayFault NOTIFICATION-TYPE SEVERE: The output relay on the Integrated Environmental Monitor has switched to the fault state. The first argument is the number of the output relay. The second argument is the name of the output relay. The third argument is the event that caused the fault. | 1.3.6.1.4.1.318.0.175 | |
| iemRelayFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The fault condition on the output relay on the Integrated Environmental Monitor has cleared. The first argument is the number of the output relay. The second argument is the name of the output relay. | 1.3.6.1.4.1.318.0.176 | |
| bmBatManCommEstab NOTIFICATION-TYPE INFORMATIONAL: Serial Communications Established with Battery Manager. | 1.3.6.1.4.1.318.0.177 | |
| bmBatManCommLost NOTIFICATION-TYPE SEVERE: Serial Communications Lost with Battery Manager. | 1.3.6.1.4.1.318.0.178 | |
| bmBatManKneeAlarm NOTIFICATION-TYPE SEVERE: Battery Voltage Knee Threshold Alarm Detected. | 1.3.6.1.4.1.318.0.179 | |
| bmBatManKneeAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared. | 1.3.6.1.4.1.318.0.180 | |
| bmBatManChargerAlarm NOTIFICATION-TYPE WARNING: Charger Alarm Detected. | 1.3.6.1.4.1.318.0.181 | |
| bmBatManChargerAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Charger Alarm Cleared. | 1.3.6.1.4.1.318.0.182 | |
| bmBatManBatteryAlarm NOTIFICATION-TYPE WARNING: Battery Alarm Detected. | 1.3.6.1.4.1.318.0.183 | |
| bmBatManBatteryAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Battery Alarm Cleared. | 1.3.6.1.4.1.318.0.184 | |
| bmBatManEnvironmentAlarm NOTIFICATION-TYPE WARNING: Environment Alarm Detected. | 1.3.6.1.4.1.318.0.185 | |
| bmBatManEnvironmentAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Environment Alarm Cleared. | 1.3.6.1.4.1.318.0.186 | |
| bmBatManMaintenanceAlarm NOTIFICATION-TYPE INFORMATIONAL: Maintenance Alarm Detected. | 1.3.6.1.4.1.318.0.187 | |
| bmBatManMaintenanceAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Maintenance Alarm Cleared. | 1.3.6.1.4.1.318.0.188 | |
| pduCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.189 | |
| pduCommunicationLost NOTIFICATION-TYPE SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.190 | |
| pduUtilityLineUndervoltage NOTIFICATION-TYPE SEVERE: Utility Line Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.191 | |
| pduUtilityLineUndervoltageCleared NOTIFICATION-TYPE INFORMATIONAL: Utility Line Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.192 | |
| pduUtilityLineOvervoltage NOTIFICATION-TYPE SEVERE: Utility Line Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.193 | |
| pduUtilityLineOvervoltageCleared NOTIFICATION-TYPE INFORMATIONAL: Utility Line Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.194 | |
| pduGroundOvercurrent NOTIFICATION-TYPE SEVERE: Ground Overcurrent. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.195 | |
| pduGroundOvercurrentCleared NOTIFICATION-TYPE INFORMATIONAL: Ground Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.196 | |
| pduCircuitPanelInputUndervoltage NOTIFICATION-TYPE SEVERE: Circuit Panel Input Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.197 | |
| pduCircuitPanelInputUndervoltageCleared NOTIFICATION-TYPE INFORMATIONAL: Circuit Panel Input Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.198 | |
| pduCircuitPanelInputOvervoltage NOTIFICATION-TYPE SEVERE: Circuit Panel Input Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.199 | |
| pduCircuitPanelInputOvervoltageCleared NOTIFICATION-TYPE INFORMATIONAL: Circuit Panel Input Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.200 | |
| pduCircuitPanelInputUndercurrent NOTIFICATION-TYPE SEVERE: Circuit Panel Input Undercurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.201 | |
| pduCircuitPanelInputUndercurrentCleared NOTIFICATION-TYPE INFORMATIONAL: Circuit Panel Input Undercurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.202 | |
| pduCircuitPanelInputOvercurrent NOTIFICATION-TYPE SEVERE: Circuit Panel Input Overcurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.203 | |
| pduCircuitPanelInputOvercurrentCleared NOTIFICATION-TYPE INFORMATIONAL: Circuit Panel Input Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.204 | |
| pduCircuitPanelFrequencyOutOfRange NOTIFICATION-TYPE SEVERE: Circuit Panel Input Frequency Out Of Range. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.205 | |
| pduCircuitPanelFrequencyOutofRangeCleared NOTIFICATION-TYPE INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.206 | |
| pduCircuitPanelNeutralOvercurrent NOTIFICATION-TYPE SEVERE: Circuit Panel Input Neutral Overcurrent. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.207 | |
| pduCircuitPanelNeutralOvercurrentCleared NOTIFICATION-TYPE INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.208 | |
| pduSystemOff NOTIFICATION-TYPE SEVERE: PDU System Off. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.209 | |
| pduOnBatteryMode NOTIFICATION-TYPE SEVERE: PDU is in On Battery Mode. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.210 | |
| pduMaintenanceBypassMode NOTIFICATION-TYPE INFORMATIONAL: PDU is in Maintenance Bypass Mode. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.211 | |
| pduAtypicalBypassMode NOTIFICATION-TYPE WARNING: PDU is in Atypical Bypass Mode. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.212 | |
| pduNoPanelFeedMode NOTIFICATION-TYPE SEVERE: PDU is in No Panel Feed Mode. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.213 | |
| pduUpsOperationMode NOTIFICATION-TYPE INFORMATIONAL: PDU is in Ups Operation Mode. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.214 | |
| pduForcedBypassMode NOTIFICATION-TYPE WARNING: PDU is in Forced Bypass Mode. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.215 | |
| pduInputTransformerOverTemperature NOTIFICATION-TYPE SEVERE: Input Transformer Over Temperature. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.216 | |
| pduInputTransformerOverTemperatureCleared NOTIFICATION-TYPE INFORMATIONAL: Input Transformer Over Temperature Cleared. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.217 | |
| pduUPSInputVoltageLost NOTIFICATION-TYPE SEVERE: UPS Input Voltage phase-N Lost. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.218 | |
| pduUPSInputVoltageRestored NOTIFICATION-TYPE INFORMATIONAL: UPS Input Voltage phase-N Restored. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.219 | |
| pduContactFault NOTIFICATION-TYPE SEVERE: A contact closure in the PDU is in an abnormal position. The first argument is the serial number. The second argument is the device name. The third argument is the number of the contact. | 1.3.6.1.4.1.318.0.220 | |
| pduContactFaultCleared NOTIFICATION-TYPE INFORMATIONAL: A contact closure in the PDU is in a normal position. The first argument is the serial number. The second argument is the device name. The third argument is the number of the contact. | 1.3.6.1.4.1.318.0.221 | |
| rPDUBankPhaseLowLoad NOTIFICATION-TYPE WARNING: A bank or phase on the Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data). | 1.3.6.1.4.1.318.0.222 | |
| rPDUBankPhaseLowLoadCleared NOTIFICATION-TYPE INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data). | 1.3.6.1.4.1.318.0.223 | |
| rPDUBankPhaseNearOverload NOTIFICATION-TYPE WARNING: A bank or phase of the Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data). | 1.3.6.1.4.1.318.0.224 | |
| rPDUBankPhaseNearOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data). | 1.3.6.1.4.1.318.0.225 | |
| rPDUBankPhaseOverload NOTIFICATION-TYPE SEVERE: A bank or phase of the Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data). | 1.3.6.1.4.1.318.0.226 | |
| rPDUBankPhaseOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data). | 1.3.6.1.4.1.318.0.227 | |
| aruDeviceConfigChange NOTIFICATION-TYPE INFORMATIONAL: Remote ARU Device Configuration change. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.228 | |
| rmPDUCommunicationLost NOTIFICATION-TYPE SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.229 | |
| emsCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.230 | |
| emsCommunicationLost NOTIFICATION-TYPE SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.231 | |
| emsProbeConnected NOTIFICATION-TYPE INFORMATIONAL: A probe has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name. | 1.3.6.1.4.1.318.0.232 | |
| emsProbeDisconnected NOTIFICATION-TYPE SEVERE: A probe has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name. | 1.3.6.1.4.1.318.0.233 | |
| emsSensorConnected NOTIFICATION-TYPE INFORMATIONAL: A sensor has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name. | 1.3.6.1.4.1.318.0.234 | |
| emsSensorDisconnected NOTIFICATION-TYPE SEVERE: A sensor has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name. | 1.3.6.1.4.1.318.0.235 | |
| emsSensorFault NOTIFICATION-TYPE SEVERE: A EMS sensor is in the fault condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name. | 1.3.6.1.4.1.318.0.236 | |
| emsSensorFaultCleared NOTIFICATION-TYPE INFORMATIONAL: A EMS sensor fault condition has cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name. | 1.3.6.1.4.1.318.0.237 | |
| emsBeaconConnected NOTIFICATION-TYPE INFORMATIONAL: A beacon has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.238 | |
| emsBeaconDisconnected NOTIFICATION-TYPE SEVERE: A beacon has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.239 | |
| emsBeaconOn NOTIFICATION-TYPE INFORMATIONAL: A EMS beacon has gone on. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.240 | |
| emsBeaconOff NOTIFICATION-TYPE INFORMATIONAL: A EMS beacon has gone off. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.241 | |
| emsMajorAlarm NOTIFICATION-TYPE SEVERE: A Major Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | 1.3.6.1.4.1.318.0.242 | |
| emsMajorAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Major Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | 1.3.6.1.4.1.318.0.243 | |
| emsMinorAlarm NOTIFICATION-TYPE SEVERE: A Minor Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | 1.3.6.1.4.1.318.0.244 | |
| emsMinorAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | 1.3.6.1.4.1.318.0.245 | |
| emsOutletStateAbnormal NOTIFICATION-TYPE WARNING: An outlet on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the outlet number. The fourth argument is the outlet name. The fifth argument is the current outlet state (1=ON, 2=OFF). The sixth argument is the configured normal outlet state (1=ON, 2=OFF). | 1.3.6.1.4.1.318.0.246 | |
| emsOutletStateNormal NOTIFICATION-TYPE INFORMATIONAL: An outlet on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the outlet number. The fourth argument is the outlet name. The fifth argument is the current outlet state (1=ON, 2=OFF). The sixth argument is the configured normal outlet state (1=ON, 2=OFF). | 1.3.6.1.4.1.318.0.247 | |
| emsInputContactStateAbnormal NOTIFICATION-TYPE WARNING: An input contact on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.248 | |
| emsInputContactStateNormal NOTIFICATION-TYPE INFORMATIONAL: An input contact on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.249 | |
| emsOutputRelayStateAbnormal NOTIFICATION-TYPE WARNING: An output relay on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the output relay number. The fourth argument is the output relay name. The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.250 | |
| emsOutputRelayStateNormal NOTIFICATION-TYPE INFORMATIONAL: An output relay on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the output relay number. The fourth argument is the output relay name. The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.251 | |
| emsDeviceConfigChange NOTIFICATION-TYPE INFORMATIONAL: A device configuration change has been made on the EMS. The first argument is the EMS serial number. The second argument is the EMS name. | 1.3.6.1.4.1.318.0.252 | |
| envHighTempThresholdViolation NOTIFICATION-TYPE SEVERE: High temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.253 | |
| envHighTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.254 | |
| envLowTempThresholdViolation NOTIFICATION-TYPE SEVERE: Low temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.255 | |
| envLowTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.256 | |
| envHighHumidityThresholdViolation NOTIFICATION-TYPE SEVERE: High humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.257 | |
| envHighHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.258 | |
| envLowHumidityThresholdViolation NOTIFICATION-TYPE SEVERE: Low humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.259 | |
| envLowHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.260 | |
| rPDUCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Communication with a Rack PDU has been established. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.266 | |
| rPDUCommunicationLost NOTIFICATION-TYPE SEVERE: Communication with a Rack PDU has been lost. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.267 | |
| rPDUOutletOn NOTIFICATION-TYPE INFORMATIONAL: An outlet on a Switched Rack PDU has turned on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | 1.3.6.1.4.1.318.0.268 | |
| rPDUOutletOff NOTIFICATION-TYPE INFORMATIONAL: An outlet on a Switched Rack PDU has turned off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | 1.3.6.1.4.1.318.0.269 | |
| rPDUDeviceConfigChange NOTIFICATION-TYPE INFORMATIONAL: A device configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.270 | |
| rPDUOutletConfigChange NOTIFICATION-TYPE INFORMATIONAL: An outlet configuration change has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | 1.3.6.1.4.1.318.0.271 | |
| rPDULowLoad NOTIFICATION-TYPE WARNING: A Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.272 | |
| rPDULowLoadCleared NOTIFICATION-TYPE INFORMATIONAL: The low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.273 | |
| rPDUNearOverload NOTIFICATION-TYPE WARNING: A Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.274 | |
| rPDUNearOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.275 | |
| rPDUOverload NOTIFICATION-TYPE SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.276 | |
| rPDUOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | 1.3.6.1.4.1.318.0.277 | |
| rPDUPowerSupply1Fail NOTIFICATION-TYPE SEVERE: Power Supply 1 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.278 | |
| rPDUPowerSupply1Ok NOTIFICATION-TYPE INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.279 | |
| rPDUPowerSupply2Fail NOTIFICATION-TYPE SEVERE: Power Supply 2 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.280 | |
| rPDUPowerSupply2Ok NOTIFICATION-TYPE INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name. | 1.3.6.1.4.1.318.0.281 | |
| rPDUPhaseConfigChange NOTIFICATION-TYPE INFORMATIONAL: A phase configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the phase index number. | 1.3.6.1.4.1.318.0.282 | |
| rPDUCancelPendingCommand NOTIFICATION-TYPE INFORMATIONAL: A cancel pending command has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number (0 indicates all outlets). The fourth argument is the outlet name (or device name if all outlets). | 1.3.6.1.4.1.318.0.283 | |
| aruAlinkCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Remote ARU Communication Established. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.284 | |
| aruAlinkCommunicationLost NOTIFICATION-TYPE SEVERE: Remote ARU Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.285 | |
| aruFanFail NOTIFICATION-TYPE SEVERE: Remote ARU Fan Fail. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.286 | |
| aruFanFailCleared NOTIFICATION-TYPE INFORMATIONAL: Remote ARU Fan Fail Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.287 | |
| aruSmokeAlarm NOTIFICATION-TYPE SEVERE: Remote ARU Smoke Alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.288 | |
| aruSmokeAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Remote ARU Smoke Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.289 | |
| aruHighTemperatureAlarm NOTIFICATION-TYPE WARNING: ARU Exhaust temperature has exceeded the override threshold and the ARU has increased fan speed to maintain a safe environment in the rack. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.290 | |
| aruHighTemperatureAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: ARU temperature override state has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.291 | |
| aruExhaustTemperatureAlarm NOTIFICATION-TYPE SEVERE: ARU Extreme Exhaust Temperature Alarm. The ARU is unable to control the temperature within the rack The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.292 | |
| aruExhaustTemperatureAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.293 | |
| envAlinkCommunicationEstablished NOTIFICATION-TYPE INFORMATIONAL: Remote Probe Communication Established. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name. | 1.3.6.1.4.1.318.0.294 | |
| envAlinkCommunicationLost NOTIFICATION-TYPE SEVERE: Remote Probe Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name. | 1.3.6.1.4.1.318.0.295 | |
| emsAlinkPowerOverload NOTIFICATION-TYPE SEVERE: Alink Power Overload. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.296 | |
| emsAlinkPowerOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: Alink Power Overload Cleared. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.297 | |
| upsOutletGroupTurnedOn NOTIFICATION-TYPE INFORMATIONAL: The specified Outlet Group turned on. | 1.3.6.1.4.1.318.0.298 | |
| upsOutletGroupTurnedOff NOTIFICATION-TYPE WARNING: The specified Outlet Group turned off. | 1.3.6.1.4.1.318.0.299 | |
| smwCriticalCondition NOTIFICATION-TYPE SEVERE: A Symmetra MW UPS critical condition has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.300 | |
| smwCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.301 | |
| smwWarningCondition NOTIFICATION-TYPE WARNING: A Symmetra MW UPS warning condition has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.302 | |
| smwWarningConditionCleared NOTIFICATION-TYPE WARNING: A Symmetra MW UPS warning condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.303 | |
| smwInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: A Symmetra MW UPS informational condition has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.304 | |
| smwInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.305 | |
| airCriticalCondition NOTIFICATION-TYPE SEVERE: An Air critical condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.306 | |
| airCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: An Air critical condition was cleared. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.307 | |
| airWarningCondition NOTIFICATION-TYPE WARNING: An Air warning condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.308 | |
| airWarningConditionCleared NOTIFICATION-TYPE WARNING: An Air warning condition was cleared. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.309 | |
| airInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: An Air informational condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.310 | |
| airInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: An Air informational condition was cleared. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.311 | |
| xPDUInputVoltageLowAlarm NOTIFICATION-TYPE SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.312 | |
| xPDUInputVoltageLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.313 | |
| xPDUInputVoltageHighAlarm NOTIFICATION-TYPE SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated. | 1.3.6.1.4.1.318.0.314 | |
| xPDUInputVoltageHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.315 | |
| xPDUBypassVoltageLowAlarm NOTIFICATION-TYPE SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.316 | |
| xPDUBypassVoltageLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.317 | |
| xPDUBypassVoltageHighAlarm NOTIFICATION-TYPE SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated. | 1.3.6.1.4.1.318.0.318 | |
| xPDUBypassVoltageHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.319 | |
| xPDUOutputVoltageLowAlarm NOTIFICATION-TYPE SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.320 | |
| xPDUOutputVoltageLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.321 | |
| xPDUOutputVoltageHighAlarm NOTIFICATION-TYPE SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated. | 1.3.6.1.4.1.318.0.322 | |
| xPDUOutputVoltageHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.323 | |
| xPDUOutputCurrentLowAlarm NOTIFICATION-TYPE SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.324 | |
| xPDUOutputCurrentLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.325 | |
| xPDUOutputCurrentHighAlarm NOTIFICATION-TYPE SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated. | 1.3.6.1.4.1.318.0.326 | |
| xPDUOutputCurrentHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The three-phase output current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.327 | |
| xPDUOutputFrequencyAlarm NOTIFICATION-TYPE SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the frequency deviation from the nominal in tenths of Hertz. | 1.3.6.1.4.1.318.0.328 | |
| xPDUOutputFrequencyAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.329 | |
| xPDUSystemGroundCurrentAlarm NOTIFICATION-TYPE SEVERE: The earth ground current of the device is over the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated. | 1.3.6.1.4.1.318.0.330 | |
| xPDUSystemGroundCurrentAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The earth ground current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.331 | |
| xPDUInputContactStateAbnormal NOTIFICATION-TYPE SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED). | 1.3.6.1.4.1.318.0.332 | |
| xPDUInputContactStateNormal NOTIFICATION-TYPE INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED). | 1.3.6.1.4.1.318.0.333 | |
| xPDUOutputNeutralCurrentHighAlarm NOTIFICATION-TYPE WARNING: The three-phase neutral current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated. | 1.3.6.1.4.1.318.0.334 | |
| xPDUOutputNeutralCurrentHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The output neutral current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.335 | |
| xPDUCoolingFanAlarm NOTIFICATION-TYPE SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.336 | |
| xPDUCoolingFanAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The device's cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.337 | |
| xPDUTransformerTempAlarm NOTIFICATION-TYPE SEVERE: The device's isolation transformer is over temperature. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.338 | |
| xPDUTransformerTempAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The device's isolation transformer is no longer over temperature. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.339 | |
| xPDUBranchCurrentLowAlarm NOTIFICATION-TYPE WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.340 | |
| xPDUBranchCurrentLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.341 | |
| xPDUBranchCurrentHighAlarm NOTIFICATION-TYPE WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated. | 1.3.6.1.4.1.318.0.342 | |
| xPDUBranchCurrentHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.343 | |
| xPDUInternalCommError NOTIFICATION-TYPE SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.344 | |
| emsHardwareStateAbnormal NOTIFICATION-TYPE SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being connected to the EMS ports or Alink Current limit detection. | 1.3.6.1.4.1.318.0.345 | |
| emsHardwareStateNormal NOTIFICATION-TYPE INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number. | 1.3.6.1.4.1.318.0.346 | |
| ceSevereCondition NOTIFICATION-TYPE SEVERE: A Custom Event severe condition was detected. The first variable is the custom event text message. The second variable is the custom event number. | 1.3.6.1.4.1.318.0.347 | |
| ceSevereConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Custom Event severe condition was cleared. The first variable is the custom event text message. The second variable is the custom event number. | 1.3.6.1.4.1.318.0.348 | |
| ceWarningCondition NOTIFICATION-TYPE WARNING: A Custom Event warning condition was detected. The first variable is the custom event text message. The second variable is the custom event number. | 1.3.6.1.4.1.318.0.349 | |
| ceWarningConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Custom Event warning condition was cleared. The first variable is the custom event text message. The second variable is the custom event number. | 1.3.6.1.4.1.318.0.350 | |
| ceInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: A Custom Event informational condition was detected. The first variable is the custom event text message. The second variable is the custom event number. | 1.3.6.1.4.1.318.0.351 | |
| ceInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Custom Event informational condition was cleared. The first variable is the custom event text message. The second variable is the custom event number. | 1.3.6.1.4.1.318.0.352 | |
| upsInternalOverTemperature NOTIFICATION-TYPE WARNING: The internal over temperature condition exists. | 1.3.6.1.4.1.318.0.353 | |
| upsInternalOverTemperatureCleared NOTIFICATION-TYPE INFORMATIONAL: The internal over temperature condition cleared. | 1.3.6.1.4.1.318.0.354 | |
| upsMpuReset NOTIFICATION-TYPE INFORMATIONAL: The MPU has been reset. | 1.3.6.1.4.1.318.0.355 | |
| upsOutputSwitchClosed NOTIFICATION-TYPE INFORMATIONAL: The Output Switch is closed. | 1.3.6.1.4.1.318.0.356 | |
| upsOutputSwitchOpened NOTIFICATION-TYPE INFORMATIONAL: The Output Switch is open. | 1.3.6.1.4.1.318.0.357 | |
| upsCalibrationStackChanged NOTIFICATION-TYPE INFORMATIONAL: A calibration value in the stack was changed. | 1.3.6.1.4.1.318.0.358 | |
| envMaxTempThresholdViolation NOTIFICATION-TYPE SEVERE: Max temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.359 | |
| envMaxTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Max temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.360 | |
| envMinTempThresholdViolation NOTIFICATION-TYPE SEVERE: Min temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.361 | |
| envMinTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Min temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.362 | |
| envMaxHumidityThresholdViolation NOTIFICATION-TYPE SEVERE: Max humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.363 | |
| envMaxHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Max humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.364 | |
| envMinHumidityThresholdViolation NOTIFICATION-TYPE SEVERE: Min humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.365 | |
| envMinHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Min humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name. | 1.3.6.1.4.1.318.0.366 | |
| envSTIncTempRateViolation NOTIFICATION-TYPE SEVERE: Short-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.367 | |
| envSTIncTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Short-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.368 | |
| envSTDecTempRateViolation NOTIFICATION-TYPE SEVERE: Short-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.369 | |
| envSTDecTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.370 | |
| envLTIncTempRateViolation NOTIFICATION-TYPE SEVERE: Long-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.371 | |
| envLTIncTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Long-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.372 | |
| envLTDecTempRateViolation NOTIFICATION-TYPE SEVERE: Long-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.373 | |
| envLTDecTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name. | 1.3.6.1.4.1.318.0.374 | |
| bmsCriticalCondition NOTIFICATION-TYPE SEVERE: A Battery Management System critical condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.375 | |
| bmsCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Battery Management System critical condition was cleared. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.376 | |
| bmsWarningCondition NOTIFICATION-TYPE WARNING: A Battery Management System warning condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.377 | |
| bmsWarningConditionCleared NOTIFICATION-TYPE WARNING: A Battery Management System warning condition was cleared. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.378 | |
| bmsInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: A Battery Management System informational condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.379 | |
| bmsInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A Battery Management System informational condition was cleared. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.380 | |
| xATSOutputVoltageLowAlarm NOTIFICATION-TYPE SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.381 | |
| xATSOutputVoltageLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.382 | |
| xATSOutputVoltageHighAlarm NOTIFICATION-TYPE SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm is generated. | 1.3.6.1.4.1.318.0.383 | |
| xATSOutputVoltageHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. | 1.3.6.1.4.1.318.0.384 | |
| xATSOutputCurrentLowAlarm NOTIFICATION-TYPE SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. The fifth argument is the threshold, in Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.385 | |
| xATSOutputCurrentLowAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The three-phase load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. | 1.3.6.1.4.1.318.0.386 | |
| xATSOutputCurrentHighAlarm NOTIFICATION-TYPE SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. The fifth argument is the threshold, in Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.387 | |
| xATSOutputCurrentHighAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. | 1.3.6.1.4.1.318.0.388 | |
| xATSOutputFrequencyAlarm NOTIFICATION-TYPE SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the frequency deviation from the nominal in tenths of Hertz. The fourth argument is the frequency deviation threshold in tenths of Hertz, from which the alarm was generated. | 1.3.6.1.4.1.318.0.389 | |
| xATSOutputFrequencyAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.390 | |
| xATSInternalCommError NOTIFICATION-TYPE SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.391 | |
| xATSInternalCommErrorCleared NOTIFICATION-TYPE INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.392 | |
| xATSDataCommMismatchError NOTIFICATION-TYPE SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controller and the Network Management interface. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.393 | |
| xATSDataCommMismatchErrorCleared NOTIFICATION-TYPE INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.394 | |
| xATSGenCommLost NOTIFICATION-TYPE WARNING: The XATS cannot communicate with the generator. This will make unavailable all the xATSGenerator OIDs. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.395 | |
| xATSGenCommEstablished NOTIFICATION-TYPE INFORMATIONAL: The XATS has established communication with the generator. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.396 | |
| xATSNeutralPosition NOTIFICATION-TYPE WARNING: XATS has transferred to neutral position. In this position neither Source 1 nor Source 2 is selected, and the XATS will have no output voltage. The first argument is the host device serial number. The second argument is the host device name. The third argument is the mode in which the switch is operating (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual). | 1.3.6.1.4.1.318.0.397 | |
| xATSSwitchTransferEvent NOTIFICATION-TYPE INFORMATIONAL: XATS has transferred from one source to the other. The first argument is the host device serial number. The second argument is the host device name. The third argument is the mode in which the switch is operating. (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual). The fourth argument is the input source selected (1=Source 1, 2=Source 2). The fifth argument is type of transfer that took place. (1=Closed, 2=Open, 3=Unknown) | 1.3.6.1.4.1.318.0.398 | |
| xATSInternalATSFault NOTIFICATION-TYPE SEVERE: An internal XATS fault has been detected. The XATS may have forced itself to not-in-auto mode (abnormal condition), as indicated by the xATSSwitchStatusAutoSwitchOperationalMode OID. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the detected fault. 1=Cannot Close S1 2=Cannot Close S2 3=Cannot Open S1 4=Cannot Open S2 5=Cannot Trip Open S1 6=Cannot Trip Open S2 7=Start Contact Failure 8=Voltage Sensing Failure | 1.3.6.1.4.1.318.0.399 | |
| xATSInternalATSFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The detected internal XATS fault has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the detected fault. 1=Cannot Close S1 2=Cannot Close S2 3=Cannot Open S1 4=Cannot Open S2 5=Cannot Trip Open S1 6=Cannot Trip Open S2 7=Start Contact Failure 8=Voltage Sensing Failure | 1.3.6.1.4.1.318.0.400 | |
| xATSEngineStartAsserted NOTIFICATION-TYPE INFORMATIONAL: The XATS has asserted the Engine Start contact. This should result in the generator producing output voltage. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the reason that the start signal was asserted 1=Unknown, 2=S1 Low Voltage, 3=S1 High Voltage, 4=S1 Line Imbalance, 5=S1 Freq Range, 6=S1 Bad Rotation. | 1.3.6.1.4.1.318.0.401 | |
| xATSEngineStopAsserted NOTIFICATION-TYPE INFORMATIONAL: The XATS has de-asserted the Engine Start contact. This should result in the generator shutting down, and producing no output voltage. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.402 | |
| xATSStartFailure NOTIFICATION-TYPE SEVERE: The generator failed to start. After assertion of the Engine Start signal, the quality of Source 2 was not seen as good. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the line quality at S2 1=Unknown, 2=S2 Low Voltage, 3=S2 High Voltage, 4=S2 Line Imbalance, 4=S2 Freq Range, 5=S2 Bad Rotation. | 1.3.6.1.4.1.318.0.403 | |
| xATSStopFailure NOTIFICATION-TYPE WARNING: The generator failed to stop. After de-assertion of the Engine Start signal, the quality of Source 2 continued to be seen as good. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.404 | |
| xATSNotInAutomaticMode NOTIFICATION-TYPE SEVERE: Automatic Transfer Switch is not in automatic mode. The first argument is the host device serial number. The second argument is the host device name. The xATSSwitchStatusAutoSwitchStatus OID and the xATSSwitchStatusAutoSwitchOperationalMode OID can provide more information about the state of the XATS. | 1.3.6.1.4.1.318.0.405 | |
| xATSNotInAutomaticModeCleared NOTIFICATION-TYPE INFORMATIONAL: Automatic Transfer Switch is in automatic mode. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.406 | |
| xATSEpoTripped NOTIFICATION-TYPE SEVERE: The device's Emergency Power Off (EPO) circuit is tripped. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.407 | |
| xATSEpoReset NOTIFICATION-TYPE INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been reset to the armed position. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.408 | |
| xATSEpoTestMode NOTIFICATION-TYPE WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.409 | |
| xATSEpoArmed NOTIFICATION-TYPE INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.410 | |
| xATSTestInitiated NOTIFICATION-TYPE INFORMATIONAL: A scheduled test has been initiated. The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of test initiated (1=scheduled, 2=manual). | 1.3.6.1.4.1.318.0.411 | |
| xATSTestCanceled NOTIFICATION-TYPE INFORMATIONAL: The scheduled test has been canceled The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of test initiated (1=scheduled, 2=manual). | 1.3.6.1.4.1.318.0.412 | |
| xATSTestFailed NOTIFICATION-TYPE SEVERE: The initiated test has failed. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.413 | |
| xATSTestPassed NOTIFICATION-TYPE INFORMATIONAL: The initiated test has passed switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.414 | |
| xATSInputContactStateAbnormal NOTIFICATION-TYPE SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED). | 1.3.6.1.4.1.318.0.415 | |
| xATSInputContactStateNormal NOTIFICATION-TYPE INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED). | 1.3.6.1.4.1.318.0.416 | |
| xATSRemoteStartContactMismatch NOTIFICATION-TYPE SEVERE: The state of the generator's Remote Start input and the ATS's Engine Start output do not match. This indicates something wrong in the Engine Start wiring, which must be corrected. This condition will prevent the generator from being started when needed. (See also: xATSGeneratorStatusRemoteStart and xATSSwitchStatusEngineStartSignal OIDs) The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.417 | |
| xATSRemoteStartContactMismatchCleared NOTIFICATION-TYPE INFORMATIONAL: Mismatch in the state of the generator's Remote Start input and the ATS's Engine Start output as been resolved. This indicates something wrong in the Engine Start wiring, which must be corrected. This condition will prevent the generator from being started when needed. (See also: xATSGeneratorStatusRemoteStart and xATSSwitchStatusEngineStartSignal OIDs) The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.418 | |
| xATSDoorOpenAlarm NOTIFICATION-TYPE WARNING: The XATS exterior panel door is open. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.419 | |
| xATSDoorOpenAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The external door to the device is closed. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.420 | |
| xATSDCBackupAlarm NOTIFICATION-TYPE WARNING: The XATS's DC backup has been lost. The XATS will lose power on Source 1 failure, causing the Engine Start signal to be asserted. The XATS will then restart from Source 2. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.421 | |
| xATSDCBackupAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: DC backup alarm has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.422 | |
| xATSGeneratorLowCoolantLevelAlarm NOTIFICATION-TYPE SEVERE: Low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.423 | |
| xATSGeneratorLowCoolantLevelAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The detected low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.424 | |
| xATSGeneratorVeryLowCoolantLevelAlarm NOTIFICATION-TYPE SEVERE: Very low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.425 | |
| xATSGeneratorVeryLowCoolantLevelAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The detected Very low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.426 | |
| xATSGeneratorHighCoolantTempAlarm NOTIFICATION-TYPE SEVERE: High coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.427 | |
| xATSGeneratorHighCoolantTempAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The detected high coolant temperature has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.428 | |
| xATSGeneratorVeryHighCoolantTempAlarm NOTIFICATION-TYPE SEVERE: Very high coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.429 | |
| xATSGeneratorVeryHighCoolantTempAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.430 | |
| xATSGeneratorLowCoolantTempAlarm NOTIFICATION-TYPE WARNING: Low coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.431 | |
| xATSGeneratorLowCoolantTempAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The low coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.432 | |
| xATSGeneratorLowOilLevelAlarm NOTIFICATION-TYPE SEVERE: Low oil level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.433 | |
| xATSGeneratorLowOilLevelAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Low oil level alarm has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.434 | |
| xATSGeneratorLowBatteryVoltDuringCrankAlarm NOTIFICATION-TYPE SEVERE: The generator's battery voltage has been detected as low while cranking the engine. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.435 | |
| xATSGeneratorLowBatteryVoltDuringCrankAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The generator's low battery voltage while cranking condition has been cleared. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.436 | |
| xATSGeneratorVeryLowBatteryVoltDuringCrankAlarm NOTIFICATION-TYPE SEVERE: The generator's battery voltage has been detected as very low while cranking the engine. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.437 | |
| xATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The generator's high battery voltage while cranking condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.438 | |
| xATSGeneratorEStop NOTIFICATION-TYPE SEVERE: The generator's emergency stop input has been activated. After the emergency stop signal has been removed, the E-Stop condition must be cleared before the generator can be started again. E-Stop conditions can only be cleared via the generator front panel. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE). | 1.3.6.1.4.1.318.0.439 | |
| xATSGeneratorEStopCleared NOTIFICATION-TYPE INFORMATIONAL: The generator's emergency stop condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE). | 1.3.6.1.4.1.318.0.440 | |
| xATSGeneratorHighBatteryVolt NOTIFICATION-TYPE WARNING: The generator's battery voltage has been detected as high. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.441 | |
| xATSGeneratorHighBatteryVoltCleared NOTIFICATION-TYPE INFORMATIONAL: The detected high battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.442 | |
| xATSGeneratorLowBatteryVolt NOTIFICATION-TYPE SEVERE: The generator's battery voltage has been detected as low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.443 | |
| xATSGeneratorLowBatteryVoltCleared NOTIFICATION-TYPE INFORMATIONAL: The detected low battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.444 | |
| xATSGeneratorControlSwitchNotAuto NOTIFICATION-TYPE SEVERE: The control switch on the generator is not in auto position. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.445 | |
| xATSGeneratorControlSwitchNotAutoCleared NOTIFICATION-TYPE INFORMATIONAL: The control switch on the generator is in auto position. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.446 | |
| xATSGeneratorLowOilPressure NOTIFICATION-TYPE SEVERE: The generator's oil pressure has been detected as low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.447 | |
| xATSGeneratorLowOilPressureCleared NOTIFICATION-TYPE INFORMATIONAL: The detected low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.448 | |
| xATSGeneratorVeryLowOilPressure NOTIFICATION-TYPE SEVERE: The generator's oil pressure has been detected as very low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.449 | |
| xATSGeneratorVeryLowOilPressureCleared NOTIFICATION-TYPE INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.450 | |
| xATSGeneratorOverload NOTIFICATION-TYPE SEVERE: The generator is overloaded. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.451 | |
| xATSGeneratorOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The generator is running within loading limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.452 | |
| xATSGeneratorLowACVEvent NOTIFICATION-TYPE SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.453 | |
| xATSGeneratorLowACVEventCleared NOTIFICATION-TYPE INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.454 | |
| xATSGeneratorHighACVEvent NOTIFICATION-TYPE SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.455 | |
| xATSGeneratorHighACVEventCleared NOTIFICATION-TYPE INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.456 | |
| xATSGeneratorOverspeed NOTIFICATION-TYPE SEVERE: The generator is running over the acceptable RPM. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.457 | |
| xATSGeneratorOverspeedCleared NOTIFICATION-TYPE INFORMATIONAL: The generator overspeed shutdown has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.458 | |
| xATSGeneratorEngineCold NOTIFICATION-TYPE SEVERE: The generator engine is cold, may not start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.459 | |
| xATSGeneratorEngineColdCleared NOTIFICATION-TYPE INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.460 | |
| xATSGeneratorOutputBreakerOpen NOTIFICATION-TYPE SEVERE: The generators output breaker has been detected as open. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.461 | |
| xATSGeneratorOutputBreakerOpenCleared NOTIFICATION-TYPE INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.462 | |
| xATSGeneratorLowFuelLevelAlarm NOTIFICATION-TYPE WARNING: The tank fuel level is below the limits specified in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured fuel level in percent of full. | 1.3.6.1.4.1.318.0.463 | |
| xATSGeneratorLowFuelLevelAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The tank fuel level is back above the specified limit. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.464 | |
| xATSGeneratorVeryLowFuelLevelAlarm NOTIFICATION-TYPE SEVERE: The tank fuel level is below the low threshold limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured tank fuel level in percent of full. | 1.3.6.1.4.1.318.0.465 | |
| xATSGeneratorVeryLowFuelLevelAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The detected low tank level has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.466 | |
| xATSGeneratorLowRunTimeAlarm NOTIFICATION-TYPE WARNING: The estimated runtime is below the limits specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the estimated runtime in hours. | 1.3.6.1.4.1.318.0.467 | |
| xATSGeneratorLowRunTimeAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.468 | |
| xATSGeneratorVeryLowRunTimeAlarm NOTIFICATION-TYPE SEVERE: The estimated runtime is below the limits specified in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID. The first argument is the host device serial number. The second argument is the host device name. The third argument is the estimated runtime in hours. | 1.3.6.1.4.1.318.0.469 | |
| xATSGeneratorVeryLowRunTimeAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.470 | |
| xATSGeneratorServiceDueAlarm NOTIFICATION-TYPE WARNING: The generator is due for scheduled service. Generation of this alarm is based on calendar days since and/or actual generator run-hours since last service. This alarm is cleared using the xATSGeneratorServiceResetRecord OID. (See also: xATSGeneratorServiceCalendarIntervalThreshold and xATSGeneratorServiceRunHoursThreshold OIDs) The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.471 | |
| xATSGeneratorServiceDueAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The generator's service registers have been reset. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.472 | |
| xATSGeneratorShutdown NOTIFICATION-TYPE SEVERE: The generator is shutdown. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.473 | |
| xATSGeneratorShutdownCleared NOTIFICATION-TYPE INFORMATIONAL: The generator shutdown alarm is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.474 | |
| xATSGeneratorBatteryCharger NOTIFICATION-TYPE SEVERE: The generator battery charger is nonfunctional. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.475 | |
| xATSGeneratorBatteryChargerCleared NOTIFICATION-TYPE INFORMATIONAL: Fault in the generator battery charger is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.476 | |
| xATSGeneratorGenericEvent NOTIFICATION-TYPE WARNING: Any generic generator event. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.477 | |
| xATSGeneratorGenericEventCleared NOTIFICATION-TYPE INFORMATIONAL: Generated generic generator event is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.478 | |
| xPDUInternalCommErrorCleared NOTIFICATION-TYPE INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.479 | |
| xPDUSystemStateAlarm NOTIFICATION-TYPE SEVERE: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead to system unavailability. it may signify a temporary condition, when the breakers are placed in an atypical manner as the user transitions to (UPS OPERATION or MAINTENANCE BYPASS) The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass. | 1.3.6.1.4.1.318.0.480 | |
| xPDUSystemStateAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration that is a non-alarm state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass. | 1.3.6.1.4.1.318.0.481 | |
| xPDUEpoTestMode NOTIFICATION-TYPE WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.482 | |
| xPDUEpoArmed NOTIFICATION-TYPE INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.483 | |
| xPDUFuseBlownAlarm NOTIFICATION-TYPE SEVERE: One or more fuses in this PDU have been detected as open. These fuses are in the feed to the UPS associated with this PDU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.484 | |
| xPDUFuseBlownAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A previous check fuse alarm in this PDU has cleared. These fuses are in the feed to the UPS associated with this PDU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.485 | |
| xPDUBreakerPositionAlarm NOTIFICATION-TYPE SEVERE: A PDU breaker is in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). note: The OUTPUT breaker position alarm is applicable only for PDUs with no system bypass. The fourth argument is the breaker position (1=OPEN, 2=CLOSED). | 1.3.6.1.4.1.318.0.486 | |
| xPDUBreakerPositionAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). note: The OUTPUT breaker position alarm cleared is applicable only for PDUs with no system bypass. | 1.3.6.1.4.1.318.0.487 | |
| xPDUBreakerChangeEvent NOTIFICATION-TYPE INFORMATIONAL: A system breaker or switch within the device has changed state. They are generated when any of the Q1, Q2 or Q3 breakers have changed states. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker that has changed (1=UPS FEED (Q1), 2=UPS OUTPUT(Q2), 3=MAINTENANCE BYPASS (Q3). The fourth argument is the state of the breaker that has changed (1=OPEN, 2=CLOSED). The fifth argument is a 8-bit field representing the state of all breakers in the system, when any of one of the Q1, Q2 or Q3 breakers have changed state. The bit map is represented in the following manner (b7, b6 ... b0) b0 - UPS FEED (Q1) b1 - MAINTENANCE BYPASS (Q3) b2 - UPS OUTPUT (Q2) b3 - MAIN INPUT b4 - BYPASS INPUT b5 - CROSS-TIE OUTPUT Example: value of 60 (0x3C) indicates that the CROSS_TIE, BYPASS and MAIN INPUT, and Q2 breakers are CLOSED and Q3, Q1 breakers are OPEN. | 1.3.6.1.4.1.318.0.488 | |
| xPDUDataCommMismatchError NOTIFICATION-TYPE SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controller and the Network Management interface. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.489 | |
| xPDUDataCommMismatchErrorCleared NOTIFICATION-TYPE INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.490 | |
| xPDUSystemInMaintenanceBypassMode NOTIFICATION-TYPE WARNING: The PDU state has changed to maintenance bypass mode. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.491 | |
| xPDUSystemInUPSOperationalMode NOTIFICATION-TYPE INFORMATIONAL: The PDU state has changed to UPS operational mode. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.492 | |
| xATSGeneratorFuelTankRuptureAlarm NOTIFICATION-TYPE WARNING: Detected a rupture in the inner wall of the generator fuel tank. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.493 | |
| xATSGeneratorFuelTankRuptureAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The rupture in the inner wall of the generator is not detected. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.494 | |
| xATSGeneratorGroundFaultAlarm NOTIFICATION-TYPE SEVERE: Generator ground fault alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.495 | |
| xATSGeneratorGroundFaultAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Generator ground fault alarm cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. | 1.3.6.1.4.1.318.0.496 | |
| xATSOutputLoadPoweredByGeneratorAlarm NOTIFICATION-TYPE WARNING: The system load on the output of the ATS is being powered by source 2 (generator). The first argument is the host device serial number. The second argument is the host device name. The third argument indicates if the load is powered by the generator, when 'load testing' the generator (1 = LIVE, 2 = TEST). | 1.3.6.1.4.1.318.0.497 | |
| xATSOutputLoadPoweredByGeneratorAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The system load on the output of the ATS is no longer being powered by source 2 (generator). The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.498 | |
| xAPCControllerFirmwareUpdateTransferStart NOTIFICATION-TYPE INFORMATIONAL: Start controller firmware transfer in the device. The first argument is the host device serial number. The second argument is the host model name that initiated the transfer. The third argument is the name of the file that is transferred. The fourth argument is the updated revision of the file, if available The fifth argument is the reason for the update, if available (1=User request, 2=Automatic upgrade by NMC, 3=Unknown). | 1.3.6.1.4.1.318.0.499 | |
| xAPCControllerFirmwareUpdateTransferComplete NOTIFICATION-TYPE INFORMATIONAL: Transfer of controller firmware was completed in the device. The first argument is the host device serial number. The second argument is the host device model name that completed the transfer. The third argument is the name of the file that was transferred. The fourth argument is the revision of the file that was transferred, if available. | 1.3.6.1.4.1.318.0.500 | |
| xAPCControllerFirmwareUpdateTransferFailed NOTIFICATION-TYPE SEVERE: Transfer of controller firmware failed. The first argument is the host device serial number. The second argument is the host device model name that failed to transfer. The third argument is the name of the file that failed the transfer, if available. The fourth argument is the reason for failure. | 1.3.6.1.4.1.318.0.501 | |
| upsPfcInputRelayFailure NOTIFICATION-TYPE WARNING: The PFC (Power Factor Correction) input relay failure exists. | 1.3.6.1.4.1.318.0.502 | |
| upsPfcInputRelayFailureCleared NOTIFICATION-TYPE INFORMATIONAL: The PFC (Power Factor Correction) input relay failure cleared. | 1.3.6.1.4.1.318.0.503 | |
| upsInverterOverTemperature NOTIFICATION-TYPE WARNING: The inverter over temperature condition exists. | 1.3.6.1.4.1.318.0.504 | |
| upsInverterOverTemperatureCleared NOTIFICATION-TYPE INFORMATIONAL: The inverter over temperature condition cleared. | 1.3.6.1.4.1.318.0.505 | |
| upsBatteryOverVoltage NOTIFICATION-TYPE WARNING: The battery over voltage condition exists. | 1.3.6.1.4.1.318.0.506 | |
| upsBatteryOverVoltageCleared NOTIFICATION-TYPE INFORMATIONAL: The battery over voltage condition cleared. | 1.3.6.1.4.1.318.0.507 | |
| upsEepromFault NOTIFICATION-TYPE WARNING: The EEPROM fault exists. | 1.3.6.1.4.1.318.0.508 | |
| upsEepromFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The EEPROM fault cleared. | 1.3.6.1.4.1.318.0.509 | |
| aruFanRuntimeAlarm NOTIFICATION-TYPE WARNING: The total running hours for a fan has exceeded the run hour threshold. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU. | 1.3.6.1.4.1.318.0.510 | |
| aruFanRuntimeAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The total running hours for a fan is no longer above the fan runhour threshold. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU. | 1.3.6.1.4.1.318.0.511 | |
| aruFanPoorPerformanceAlarm NOTIFICATION-TYPE WARNING: Poor fan performance has been detected in the ARU, indicating that the fan may be close to failing. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU. | 1.3.6.1.4.1.318.0.512 | |
| aruFanPoorPerformanceAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Fan performance is no longer degraded. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU. | 1.3.6.1.4.1.318.0.513 | |
| aruRedundantPowerLostAlarm NOTIFICATION-TYPE WARNING: One of the redundant line cords on the ARU is no longer receiving AC power. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.514 | |
| aruRedundantPowerLostAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: Line-cord redundancy has been restored to the ARU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. | 1.3.6.1.4.1.318.0.515 | |
| apcDeviceConfigChange NOTIFICATION-TYPE INFORMATIONAL: A device configuration change has been made on the device. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.516 | |
| apcEnvSensorConnected NOTIFICATION-TYPE INFORMATIONAL: A sensor has been connected to the host device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.517 | |
| apcEnvSensorDisconnected NOTIFICATION-TYPE SEVERE: A sensor has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.518 | |
| apcEnvMaxTempThresholdViolation NOTIFICATION-TYPE SEVERE: Max temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.519 | |
| apcEnvMaxTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Max temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.520 | |
| apcEnvHighTempThresholdViolation NOTIFICATION-TYPE WARNING: High temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.521 | |
| apcEnvHighTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.522 | |
| apcEnvLowTempThresholdViolation NOTIFICATION-TYPE WARNING: Low temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.523 | |
| apcEnvLowTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.524 | |
| apcEnvMinTempThresholdViolation NOTIFICATION-TYPE SEVERE: Min temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.525 | |
| apcEnvMinTempThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Min temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The sixth argument is the sensor number. The seventh argument is the sensor name. | 1.3.6.1.4.1.318.0.526 | |
| apcEnvSTIncTempRateViolation NOTIFICATION-TYPE SEVERE: Short-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.527 | |
| apcEnvSTIncTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Short-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.528 | |
| apcEnvSTDecTempRateViolation NOTIFICATION-TYPE SEVERE: Short-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.529 | |
| apcEnvSTDecTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Short-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.530 | |
| apcEnvLTIncTempRateViolation NOTIFICATION-TYPE SEVERE: Long-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.531 | |
| apcEnvLTIncTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Long-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.532 | |
| apcEnvLTDecTempRateViolation NOTIFICATION-TYPE SEVERE: Long-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.533 | |
| apcEnvLTDecTempRateViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Long-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.534 | |
| apcEnvMaxHumidityThresholdViolation NOTIFICATION-TYPE SEVERE: Max humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.535 | |
| apcEnvMaxHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Max humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.536 | |
| apcEnvHighHumidityThresholdViolation NOTIFICATION-TYPE WARNING: High humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.537 | |
| apcEnvHighHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.538 | |
| apcEnvLowHumidityThresholdViolation NOTIFICATION-TYPE WARNING: Low humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.539 | |
| apcEnvLowHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.540 | |
| apcEnvMinHumidityThresholdViolation NOTIFICATION-TYPE SEVERE: Min humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.541 | |
| apcEnvMinHumidityThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Min humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name. | 1.3.6.1.4.1.318.0.542 | |
| apcBeaconConnected NOTIFICATION-TYPE INFORMATIONAL: A beacon has been connected to the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.543 | |
| apcBeaconDisconnected NOTIFICATION-TYPE SEVERE: A beacon has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.544 | |
| apcBeaconOn NOTIFICATION-TYPE INFORMATIONAL: A beacon has gone on (activated). The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.545 | |
| apcBeaconOff NOTIFICATION-TYPE INFORMATIONAL: A beacon has gone off (deactivated). The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.546 | |
| apcOutletStateAbnormal NOTIFICATION-TYPE WARNING: An outlet on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the outlet number. The fifth argument is the outlet name. The sixth argument is the current outlet state (1=ON, 2=OFF). The seventh argument is the configured normal outlet state (1=ON, 2=OFF). | 1.3.6.1.4.1.318.0.547 | |
| apcOutletStateNormal NOTIFICATION-TYPE INFORMATIONAL: An outlet on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the outlet number. The fifth argument is the outlet name. The sixth argument is the current outlet state (1=ON, 2=OFF). The seventh argument is the configured normal outlet state (1=ON, 2=OFF). | 1.3.6.1.4.1.318.0.548 | |
| apcOutputRelayStateAbnormal NOTIFICATION-TYPE WARNING: An output relay on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the output relay number. The fifth argument is the output relay name. The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.549 | |
| apcOutputRelayStateNormal NOTIFICATION-TYPE INFORMATIONAL: An output relay on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the output relay number. The fifth argument is the output relay name. The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.550 | |
| apcHardwareStateAbnormal NOTIFICATION-TYPE SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being connected to device ports or Alink Current limit detection. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is a hardware specific state code. | 1.3.6.1.4.1.318.0.551 | |
| apcHardwareStateNormal NOTIFICATION-TYPE INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.552 | |
| apcCriticalDiscreteInputContactStateAbnormal NOTIFICATION-TYPE SEVERE: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.553 | |
| apcCriticalDiscreteInputContactStateNormal NOTIFICATION-TYPE INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.554 | |
| apcWarningDiscreteInputContactStateAbnormal NOTIFICATION-TYPE WARNING: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.555 | |
| apcWarningDiscreteInputContactStateNormal NOTIFICATION-TYPE INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.556 | |
| apcInformationalDiscreteInputContactStateAbnormal NOTIFICATION-TYPE INFORMATIONAL: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.557 | |
| apcInformationalDiscreteInputContactStateNormal NOTIFICATION-TYPE INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN). | 1.3.6.1.4.1.318.0.558 | |
| apcAnalogInputMaxThresholdViolation NOTIFICATION-TYPE SEVERE: Maximum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.559 | |
| apcAnalogInputMaxThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Maximum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.560 | |
| apcAnalogInputHighThresholdViolation NOTIFICATION-TYPE WARNING: High threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.561 | |
| apcAnalogInputHighThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: High threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.562 | |
| apcAnalogInputLowThresholdViolation NOTIFICATION-TYPE WARNING: Low threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.563 | |
| apcAnalogInputLowThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Low threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.564 | |
| apcAnalogInputMinThresholdViolation NOTIFICATION-TYPE SEVERE: Minimum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.565 | |
| apcAnalogInputMinThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: Minimum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name. | 1.3.6.1.4.1.318.0.566 | |
| apcDeviceClearLostComms NOTIFICATION-TYPE INFORMATIONAL: Lost communications reset command has been issued. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.567 | |
| apcDeviceConnected NOTIFICATION-TYPE INFORMATIONAL: A device has been connected to the host. The first argument is the host serial number. The second argument is the host name. The third argument is the device number. The fourth argument is the device name. | 1.3.6.1.4.1.318.0.568 | |
| apcDeviceDisconnected NOTIFICATION-TYPE SEVERE: A device has been disconnected from the host. The first argument is the host serial number. The second argument is the host name. The third argument is the device number. The fourth argument is the device name. | 1.3.6.1.4.1.318.0.569 | |
| apcUnregisteredUserAccessDenied NOTIFICATION-TYPE INFORMATIONAL: An unregistered user has tried to access the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argumant is the door identifier. The fifth argument is the unregistered user's RFID. | 1.3.6.1.4.1.318.0.570 | |
| apcRegisteredUserAccessDenied NOTIFICATION-TYPE INFORMATIONAL: A registered user has been denied access to the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argumant is the door identifier. The fifth argument is the user name. | 1.3.6.1.4.1.318.0.571 | |
| apcRegisteredUserConfigChange NOTIFICATION-TYPE INFORMATIONAL: Registered user configuration change. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name. | 1.3.6.1.4.1.318.0.572 | |
| apcDoorUnlocked NOTIFICATION-TYPE INFORMATIONAL: A door has been unlocked. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier. The fifth argument is the door access user. The sixth argument is the door access type. | 1.3.6.1.4.1.318.0.573 | |
| apcDoorLocked NOTIFICATION-TYPE INFORMATIONAL: A door has been locked. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier. The fifth argument is the door access user. The sixth argument is the door access type. | 1.3.6.1.4.1.318.0.574 | |
| apcHandleOpened NOTIFICATION-TYPE INFORMATIONAL: A door handle has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.575 | |
| apcHandleClosed NOTIFICATION-TYPE INFORMATIONAL: A door handle has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.576 | |
| apcDoorOpened NOTIFICATION-TYPE INFORMATIONAL: A door has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.577 | |
| apcDoorClosed NOTIFICATION-TYPE INFORMATIONAL: A door has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.578 | |
| apcKeyOverrideUnlocked NOTIFICATION-TYPE SEVERE: Key override unlock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.580 | |
| apcKeyOverrideLocked NOTIFICATION-TYPE INFORMATIONAL: Key override lock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.581 | |
| apcForcedEntry NOTIFICATION-TYPE SEVERE: A forced entry condition has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.582 | |
| apcForcedEntryCleared NOTIFICATION-TYPE INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.583 | |
| apcRelockTimeout NOTIFICATION-TYPE SEVERE: A relock timout has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.584 | |
| apcRelockTimeoutCleared NOTIFICATION-TYPE INFORMATIONAL: A relock timout has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.585 | |
| apcDoorSenseDisconnected NOTIFICATION-TYPE SEVERE: A door sensor was disconnected. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.586 | |
| apcDoorSenseConnected NOTIFICATION-TYPE INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.587 | |
| apcDoorLostComms NOTIFICATION-TYPE SEVERE: Communications have been lost with the door. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.588 | |
| apcDoorEstablishedComms NOTIFICATION-TYPE INFORMATIONAL: Communications have been established with the door. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.589 | |
| apcRegisteredUserAccessChange NOTIFICATION-TYPE INFORMATIONAL: Registered user access changed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name. | 1.3.6.1.4.1.318.0.590 | |
| apcUnregisteredUserStatusChange NOTIFICATION-TYPE INFORMATIONAL: Unregistered user status changed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name. | 1.3.6.1.4.1.318.0.591 | |
| apcDeviceClearUserConfigs NOTIFICATION-TYPE INFORMATIONAL: User configurations reset command has been issued. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number. | 1.3.6.1.4.1.318.0.592 | |
| upsBatteryTempSensorFault NOTIFICATION-TYPE WARNING: The battery temperature sensor fault exists. | 1.3.6.1.4.1.318.0.600 | |
| upsBatteryTempSensorFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The battery temperature sensor fault cleared. | 1.3.6.1.4.1.318.0.601 | |
| upsBatterySoftBusStartFault NOTIFICATION-TYPE WARNING: A battery bus soft start fault exists. | 1.3.6.1.4.1.318.0.602 | |
| upsBatterySoftBusStartFaultCleared NOTIFICATION-TYPE INFORMATIONAL: A battery bus soft start fault exists cleared. | 1.3.6.1.4.1.318.0.603 | |
| apcOutputShortCircuit NOTIFICATION-TYPE WARNING: An output short circuit condition exists. | 1.3.6.1.4.1.318.0.604 | |
| apcOutputShortCircuitCleared NOTIFICATION-TYPE INFORMATIONAL: An output short circuit condition cleared. | 1.3.6.1.4.1.318.0.605 | |
| apcOutputRelayFault NOTIFICATION-TYPE WARNING: An output relay (or its driver) fault exists. | 1.3.6.1.4.1.318.0.606 | |
| apcOutputRelayFaultCleared NOTIFICATION-TYPE INFORMATIONAL: An output relay (or its driver) fault cleared. | 1.3.6.1.4.1.318.0.607 | |
| upsPfcFault NOTIFICATION-TYPE WARNING: A PFC fault exists. | 1.3.6.1.4.1.318.0.608 | |
| upsPfcFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The PFC fault cleared. | 1.3.6.1.4.1.318.0.609 | |
| apcDcBusOverVoltage NOTIFICATION-TYPE WARNING: The DC bus voltage is too high. | 1.3.6.1.4.1.318.0.610 | |
| apcDcBusOverVoltageCleared NOTIFICATION-TYPE INFORMATIONAL: The DC bus voltage is too high cleared. | 1.3.6.1.4.1.318.0.611 | |
| upsInverterFault NOTIFICATION-TYPE WARNING: The inverter fault exists. | 1.3.6.1.4.1.318.0.612 | |
| upsInverterFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The inverter fault cleared. | 1.3.6.1.4.1.318.0.613 | |
| apcAdConverterFault NOTIFICATION-TYPE WARNING: The A/D converter fault exists. | 1.3.6.1.4.1.318.0.614 | |
| apcAdConverterFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The A/D converter fault cleared. | 1.3.6.1.4.1.318.0.615 | |
| apcLogicPowerSupplyFault NOTIFICATION-TYPE WARNING: A logic power supply fault exists. | 1.3.6.1.4.1.318.0.616 | |
| apcLogicPowerSupplyFaultCleared NOTIFICATION-TYPE INFORMATIONAL: A logic power supply fault cleared. | 1.3.6.1.4.1.318.0.617 | |
| apcTransformerDCImbalanceFault NOTIFICATION-TYPE WARNING: The DC component of the transformer's current is too high. | 1.3.6.1.4.1.318.0.618 | |
| apcTransformerDCImbalanceFaultCleared NOTIFICATION-TYPE WARNING: The DC component of the transformer's current is normal. | 1.3.6.1.4.1.318.0.619 | |
| upsBackfeedRelayFault NOTIFICATION-TYPE WARNING: The backfeed relay (or its driver) has a fault. | 1.3.6.1.4.1.318.0.620 | |
| upsBackfeedRelayFaultCleared NOTIFICATION-TYPE WARNING: The backfeed relay (or its driver) has a fault cleared. | 1.3.6.1.4.1.318.0.621 | |
| upsBypassRelayFault NOTIFICATION-TYPE WARNING: A bypass relay (or its driver) has a fault. | 1.3.6.1.4.1.318.0.622 | |
| upsBypassRelayFaultCleared NOTIFICATION-TYPE WARNING: A bypass relay (or its driver) has a fault cleared. | 1.3.6.1.4.1.318.0.623 | |
| xPDUBranchCurrentMinAlarm NOTIFICATION-TYPE SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.626 | |
| xPDUBranchCurrentMinAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.627 | |
| xPDUBranchCurrentMaxAlarm NOTIFICATION-TYPE SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated. | 1.3.6.1.4.1.318.0.628 | |
| xPDUBranchCurrentMaxAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. | 1.3.6.1.4.1.318.0.629 | |
| rPDUOutletLowLoad NOTIFICATION-TYPE WARNING: A Rack PDU has violated the outlet low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. | 1.3.6.1.4.1.318.0.630 | |
| rPDUOutletLowLoadCleared NOTIFICATION-TYPE INFORMATIONAL: The outlet low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. | 1.3.6.1.4.1.318.0.631 | |
| rPDUOutletNearOverload NOTIFICATION-TYPE WARNING: A Rack PDU is near an outlet overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. | 1.3.6.1.4.1.318.0.632 | |
| rPDUOutletNearOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The outlet near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. | 1.3.6.1.4.1.318.0.633 | |
| rPDUOutletOverload NOTIFICATION-TYPE SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. | 1.3.6.1.4.1.318.0.634 | |
| rPDUOutletOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The outlet overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. | 1.3.6.1.4.1.318.0.635 | |
| apcTestTrap NOTIFICATION-TYPE INFORMATIONAL: Trap used to test SNMP trap functionality. The first argument is a place holder for test variables. | 1.3.6.1.4.1.318.0.636 | |
| baseFanFailureCleared NOTIFICATION-TYPE INFORMATIONAL: Base module fan has been repaired | 1.3.6.1.4.1.318.0.637 | |
| atsLowLoad NOTIFICATION-TYPE WARNING: ATS has violated the bank or phase low load threshold. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist. | 1.3.6.1.4.1.318.0.638 | |
| atsLowLoadCleared NOTIFICATION-TYPE INFORMATIONAL: The bank or phase low load condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist. | 1.3.6.1.4.1.318.0.639 | |
| atsNearOverload NOTIFICATION-TYPE WARNING: ATS has violated the bank or phase near overload threshold. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist. | 1.3.6.1.4.1.318.0.640 | |
| atsNearOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The bank or phase near overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist. | 1.3.6.1.4.1.318.0.641 | |
| atsOverload NOTIFICATION-TYPE SEVERE: ATS is in an overload condition. The first argument is the serial number. The second argument is the product name. The third argument is the phase number. The fourth argument is the bank number. -1 is returned if bank does not exist. | 1.3.6.1.4.1.318.0.642 | |
| atsOverloadCleared NOTIFICATION-TYPE INFORMATIONAL: The bank or phase overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number. The fourth argument is the bank number. -1 is returned if bank does not exist. | 1.3.6.1.4.1.318.0.643 | |
| atsRMSOverVoltage NOTIFICATION-TYPE SEVERE: Overvoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.644 | |
| atsRMSOverVoltageCleared NOTIFICATION-TYPE INFORMATIONAL: Overvoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.645 | |
| atsRMSUnderVoltage NOTIFICATION-TYPE SEVERE: Undervoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.646 | |
| atsRMSUnderVoltageCleared NOTIFICATION-TYPE INFORMATIONAL: Undervoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.647 | |
| atsRMSOverFrequency NOTIFICATION-TYPE SEVERE: OverFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.648 | |
| atsRMSOverFrequencyCleared NOTIFICATION-TYPE INFORMATIONAL: OverFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.649 | |
| atsRMSUnderFrequency NOTIFICATION-TYPE SEVERE: UnderFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.650 | |
| atsRMSUnderFrequencyCleared NOTIFICATION-TYPE INFORMATIONAL: UnderFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.651 | |
| isxModularDistributionCommLost NOTIFICATION-TYPE SEVERE: Communication with a metering segment of the modular distribution system has been lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the segment number. The fourth argument describes the modules served by this metering segment. | 1.3.6.1.4.1.318.0.652 | |
| isxModularDistributionCommEstablished NOTIFICATION-TYPE INFORMATIONAL: Communication with a metering segment of the modular distribution system has been restored. The first argument is the host device serial number. The second argument is the host device name. The third argument is the segment number. The fourth argument describes the modules served by this metering segment. | 1.3.6.1.4.1.318.0.653 | |
| isxModularDistributionModuleInserted NOTIFICATION-TYPE INFORMATIONAL: A distribution module has been inserted into the system. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module location number. | 1.3.6.1.4.1.318.0.654 | |
| isxModularDistributionModuleRemoved NOTIFICATION-TYPE INFORMATIONAL: A distribution module has been removed from the system. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module location number. | 1.3.6.1.4.1.318.0.655 | |
| isxModularBreakerOpenAlarm NOTIFICATION-TYPE SEVERE: A distribution module breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the module breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). The fifth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.656 | |
| isxModularBreakerOpenAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: An alarm caused by a distribution breaker being open has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). The fifth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.657 | |
| isxModularMinCurrentThresholdViolation NOTIFICATION-TYPE SEVERE: The current in a distribution module is below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.658 | |
| isxModularMinCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution module is no longer below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.659 | |
| isxModularLowCurrentThresholdViolation NOTIFICATION-TYPE WARNING: The current in a distribution module is below the low/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.660 | |
| isxModularLowCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution module is no longer below the low/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.661 | |
| isxModularHighCurrentThresholdViolation NOTIFICATION-TYPE WARNING: The current in a distribution module is above the high/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.662 | |
| isxModularHighCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution module is no longer above the high/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.663 | |
| isxModularMaxCurrentThresholdViolation NOTIFICATION-TYPE SEVERE: The current in a distribution module is above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.664 | |
| isxModularMaxCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution module is no longer above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker. | 1.3.6.1.4.1.318.0.665 | |
| isxModularSubfeedBreakerOpenAlarm NOTIFICATION-TYPE SEVERE: A distribution subfeed breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.666 | |
| isxModularSubfeedBreakerOpenAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: An alarm caused by a distribution subfeed breaker being open has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.667 | |
| isxModularSubfeedMinCurrentThresholdViolation NOTIFICATION-TYPE SEVERE: The current in a distribution subfeed is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.668 | |
| isxModularSubfeedMinCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution subfeed is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.669 | |
| isxModularSubfeedLowCurrentThresholdViolation NOTIFICATION-TYPE WARNING: The current in a distribution subfeed is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.670 | |
| isxModularSubfeedLowCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution subfeed is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.671 | |
| isxModularSubfeedHighCurrentThresholdViolation NOTIFICATION-TYPE WARNING: The current in a distribution subfeed is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.672 | |
| isxModularSubfeedHighCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution subfeed is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.673 | |
| isxModularSubfeedMaxCurrentThresholdViolation NOTIFICATION-TYPE SEVERE: The current in a distribution subfeed is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.674 | |
| isxModularSubfeedMaxCurrentThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The current in a distribution subfeed is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed. | 1.3.6.1.4.1.318.0.675 | |
| isxModularTotalOutputCurrentMinThresholdViolation NOTIFICATION-TYPE SEVERE: The total output current of the distribution is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.676 | |
| isxModularTotalOutputCurrentMinThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The total output current of the distribution is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.677 | |
| isxModularTotalOutputCurrentLowThresholdViolation NOTIFICATION-TYPE WARNING: The total output current of the distribution is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.678 | |
| isxModularTotalOutputCurrentLowThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The total output current of the distribution is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.679 | |
| isxModularTotalOutputCurrentHighThresholdViolation NOTIFICATION-TYPE WARNING: The total output current of the distribution is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.680 | |
| isxModularTotalOutputCurrentHighThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The total output current of the distribution is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.681 | |
| isxModularTotalOutputCurrentMaxThresholdViolation NOTIFICATION-TYPE SEVERE: The total output current of the distribution is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated. | 1.3.6.1.4.1.318.0.682 | |
| isxModularTotalOutputCurrentMaxThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The total output current of the distribution is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.683 | |
| isxModularOutputVoltageMinThresholdViolation NOTIFICATION-TYPE SEVERE: The distribution output voltage is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.684 | |
| isxModularOutputVoltageMinThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The distribution output voltage is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.685 | |
| isxModularOutputVoltageLowThresholdViolation NOTIFICATION-TYPE WARNING: The distribution output voltage is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.686 | |
| isxModularOutputVoltageLowThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The distribution output voltage is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.687 | |
| isxModularOutputVoltageHighThresholdViolation NOTIFICATION-TYPE WARNING: The distribution output voltage is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.688 | |
| isxModularOutputVoltageHighThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The distribution output voltage is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.689 | |
| isxModularOutputVoltageMaxThresholdViolation NOTIFICATION-TYPE SEVERE: The distribution output voltage is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated. | 1.3.6.1.4.1.318.0.690 | |
| isxModularOutputVoltageMaxThresholdViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The distribution output voltage is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). | 1.3.6.1.4.1.318.0.691 | |
| apcDoorClosedImproperly NOTIFICATION-TYPE SEVERE: A door has been closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.692 | |
| apcDoorClosedImproperlyCleared NOTIFICATION-TYPE INFORMATIONAL: A door is no longer closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.693 | |
| apcUserScheduleViolation NOTIFICATION-TYPE SEVERE: A user has had a door opened past the scheduled access period. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.694 | |
| apcUserScheduleViolationCleared NOTIFICATION-TYPE INFORMATIONAL: User schedule violation has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear). | 1.3.6.1.4.1.318.0.695 | |
| isxModularOutputFrequencyThresholdViolation NOTIFICATION-TYPE SEVERE: The distribution output frequency is outside of the operating range specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the threshold, in tenths of Hertz, from which the alarm was generated. | 1.3.6.1.4.1.318.0.696 | |
| isxModularOutputFrequencyViolationCleared NOTIFICATION-TYPE INFORMATIONAL: The distribution output frequency is no longer out of range. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.697 | |
| atsSourceStatusFail NOTIFICATION-TYPE SEVERE: ATS Source failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.698 | |
| atsSourceStatusOk NOTIFICATION-TYPE INFORMATIONAL: ATS Source OK. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B. | 1.3.6.1.4.1.318.0.699 | |
| atsHardwareStatusFail NOTIFICATION-TYPE SEVERE: ATS display board hardware failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the failed hardware: 0= Phase LEDs/Push-button hardware failure 1= Seven-segment display hardware failure. | 1.3.6.1.4.1.318.0.700 | |
| atsHardwareStatusOk NOTIFICATION-TYPE INFORMATIONAL: ATS display board hardware ok. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the hardware: 0= Phase LEDs/Push-button hardware failure 1= Seven-segment display hardware failure. | 1.3.6.1.4.1.318.0.701 | |
| atsControllerRestart NOTIFICATION-TYPE INFORMATIONAL: ATS Controller restarted. | 1.3.6.1.4.1.318.0.702 | |
| inputWarningError NOTIFICATION-TYPE WARNING: Input warning error has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.703 | |
| inputOK NOTIFICATION-TYPE INFORMATIONAL: Input warning error has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.704 | |
| bypassWarningError NOTIFICATION-TYPE WARNING: Bypass warning error has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.705 | |
| bypassOK NOTIFICATION-TYPE INFORMATIONAL: Bypass warning error has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.706 | |
| communicationWarningError NOTIFICATION-TYPE WARNING: Communication warning error has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.707 | |
| communicationOK NOTIFICATION-TYPE INFORMATIONAL: Communication warning error has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.708 | |
| powerModuleSevereError NOTIFICATION-TYPE SEVERE: Power module severe error has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.709 | |
| powerModuleOK NOTIFICATION-TYPE INFORMATIONAL: Power module severe error has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.710 | |
| outputVoltageWaveformError NOTIFICATION-TYPE SEVERE: Output voltage waveform error has been detected. | 1.3.6.1.4.1.318.0.711 | |
| outputVoltageWaveformOK NOTIFICATION-TYPE INFORMATIONAL: Output voltage waveform is OK. | 1.3.6.1.4.1.318.0.712 | |
| bypassStaticSwitchOverload NOTIFICATION-TYPE SEVERE: Overload on bypass static switch has been detected. | 1.3.6.1.4.1.318.0.713 | |
| noOverloadOnBypassStaticSwitch NOTIFICATION-TYPE INFORMATIONAL: Overload on static bypass switch no longer present. | 1.3.6.1.4.1.318.0.714 | |
| batteryVoltageCollapse NOTIFICATION-TYPE SEVERE: Battery voltage collapse has been detected. | 1.3.6.1.4.1.318.0.715 | |
| batteryVoltageOK NOTIFICATION-TYPE INFORMATIONAL: Battery voltage OK. | 1.3.6.1.4.1.318.0.716 | |
| overloadOnInstallation NOTIFICATION-TYPE SEVERE: Overload on installation has been detected. | 1.3.6.1.4.1.318.0.717 | |
| noOverloadOnInstallation NOTIFICATION-TYPE INFORMATIONAL: Overload on installation no longer present. | 1.3.6.1.4.1.318.0.718 | |
| bypassStaticSwitchError NOTIFICATION-TYPE SEVERE: Bypass static switch error, module has critical error. | 1.3.6.1.4.1.318.0.719 | |
| bypassStaticSwitchOK NOTIFICATION-TYPE INFORMATIONAL: Bypass static switch OK. | 1.3.6.1.4.1.318.0.720 | |
| forcedBypassSwitchActivated NOTIFICATION-TYPE SEVERE: Forced bypass switch has been activated. | 1.3.6.1.4.1.318.0.721 | |
| forcedBypassSwitchReleased NOTIFICATION-TYPE INFORMATIONAL: Forced bypass switch has been released. | 1.3.6.1.4.1.318.0.722 | |
| epoActivated NOTIFICATION-TYPE SEVERE: Emergency Power Off (EPO) switch has been activated. | 1.3.6.1.4.1.318.0.723 | |
| xATSS1BadPhaseRotation NOTIFICATION-TYPE SEVERE: The device's source 1 phase rotation is bad. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.724 | |
| xATSS1BadPhaseRotationCleared NOTIFICATION-TYPE INFORMATIONAL: The device's source 1 phase rotation is back to normal. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.725 | |
| xATSS1BadPhaseBalance NOTIFICATION-TYPE SEVERE: The device's source 1 phase balance is out of bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the minimum phase balance as a percentage. | 1.3.6.1.4.1.318.0.726 | |
| xATSS1BadPhaseBalanceCleared NOTIFICATION-TYPE INFORMATIONAL: The device's source 1 phase balance is back to normal. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.727 | |
| isxModularTransformerOverheating NOTIFICATION-TYPE SEVERE: The distribution transformer temperature is too hot. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.728 | |
| isxModularTransformerOverheatingCleared NOTIFICATION-TYPE INFORMATIONAL: The distribution transformer temperature has returned to normal. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.729 | |
| apcInternalCommunicationFault NOTIFICATION-TYPE SEVERE: An internal UPS communication fault exists. | 1.3.6.1.4.1.318.0.730 | |
| apcInternalCommunicationFaultCleared NOTIFICATION-TYPE INFORMATIONAL: An internal UPS communication fault no longer exists. | 1.3.6.1.4.1.318.0.731 | |
| upsOutletGroupCommand NOTIFICATION-TYPE WARNING: The specified Outlet Group command has been issued. | 1.3.6.1.4.1.318.0.732 | |
| onbatterycommunicationLost NOTIFICATION-TYPE SEVERE: Communication to the UPS when the UPS is on Battery. Steps to reestablish communication are in progress. | 1.3.6.1.4.1.318.0.733 | |
| upsCriticalCondition NOTIFICATION-TYPE SEVERE: A UPS critical condition was detected. The first variable is the error condition text message. The second variable is the error number. | 1.3.6.1.4.1.318.0.734 | |
| upsCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A UPS critical condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.735 | |
| upsWarningCondition NOTIFICATION-TYPE WARNING: A UPS warning condition has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.736 | |
| upsWarningConditionCleared NOTIFICATION-TYPE WARNING: A UPS warning condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.737 | |
| upsInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: A UPS informational condition has been detected. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.738 | |
| upsInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A UPS informational condition has been cleared. The first variable is the fault condition. | 1.3.6.1.4.1.318.0.739 | |
| isxcInformationalAlarm NOTIFICATION-TYPE INFORMATIONAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.740 | |
| isxcInformationalAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.741 | |
| isxcWarningAlarm NOTIFICATION-TYPE WARNING: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.742 | |
| isxcWarningAlarmCleared NOTIFICATION-TYPE WARNING: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.743 | |
| isxcErrorAlarm NOTIFICATION-TYPE ERROR: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.744 | |
| isxcErrorAlarmCleared NOTIFICATION-TYPE ERROR: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.745 | |
| isxcCriticalAlarm NOTIFICATION-TYPE CRITICAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.746 | |
| isxcCriticalAlarmCleared NOTIFICATION-TYPE CRITICAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.747 | |
| isxcFailureAlarm NOTIFICATION-TYPE FAILURE: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.748 | |
| isxcFailureAlarmCleared NOTIFICATION-TYPE FAILURE: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string. | 1.3.6.1.4.1.318.0.749 | |
| rpduCriticalCondition NOTIFICATION-TYPE SEVERE: A RPDU critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message. | 1.3.6.1.4.1.318.0.750 | |
| rpduCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A RPDU critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message. | 1.3.6.1.4.1.318.0.751 | |
| rpduWarningCondition NOTIFICATION-TYPE WARNING: A RPDU warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message. | 1.3.6.1.4.1.318.0.752 | |
| rpduWarningConditionCleared NOTIFICATION-TYPE WARNING: A RPDU warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message. | 1.3.6.1.4.1.318.0.753 | |
| rpduInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: A RPDU informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message. | 1.3.6.1.4.1.318.0.754 | |
| rpduInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A RPDU informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message. | 1.3.6.1.4.1.318.0.755 | |
| isxModularCoolingFanAlarm NOTIFICATION-TYPE SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.756 | |
| isxModularCoolingFanAlarmCleared NOTIFICATION-TYPE INFORMATIONAL: The device's internal cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host device name. | 1.3.6.1.4.1.318.0.757 | |
| upsFirmwareUpdateStarted NOTIFICATION-TYPE WARNING: Updating UPS firmware. | 1.3.6.1.4.1.318.0.758 | |
| upsFirmwareUpdateFinished NOTIFICATION-TYPE INFORMATIONAL: Finished updating UPS firmware. | 1.3.6.1.4.1.318.0.759 | |
| upsFirmwareUpdateSucceeded NOTIFICATION-TYPE INFORMATIONAL: UPS firmware update succeeded. | 1.3.6.1.4.1.318.0.760 | |
| upsFirmwareUpdateFailed NOTIFICATION-TYPE WARNING: UPS firmware update failed. | 1.3.6.1.4.1.318.0.761 | |
| upsHasNoValidFirmware NOTIFICATION-TYPE SEVERE: UPS has no valid firmware. | 1.3.6.1.4.1.318.0.762 | |
| upsHasNoValidFirmwareCleared NOTIFICATION-TYPE INFORMATIONAL: UPS now has a valid firmware. | 1.3.6.1.4.1.318.0.763 | |
| upsLocalDisplayButtonFault NOTIFICATION-TYPE WARNING: A local display button fault exists. | 1.3.6.1.4.1.318.0.767 | |
| upsLocalDisplayButtonFaultCleared NOTIFICATION-TYPE INFORMATIONAL: A local display button fault no longer exists. | 1.3.6.1.4.1.318.0.768 | |
| upsNeedsFactorySetupFault NOTIFICATION-TYPE SEVERE: UPS needs factory setup. | 1.3.6.1.4.1.318.0.769 | |
| upsNeedsFactorySetupFaultCleared NOTIFICATION-TYPE INFORMATIONAL: UPS no longer needs factory setup. | 1.3.6.1.4.1.318.0.770 | |
| upsEPOActive NOTIFICATION-TYPE SEVERE: Emergency Power Off (EPO) active. | 1.3.6.1.4.1.318.0.771 | |
| upsEPOActiveCleared NOTIFICATION-TYPE INFORMATIONAL: Emergency Power Off (EPO) now inactive. | 1.3.6.1.4.1.318.0.772 | |
| upsFirmwareMismatch NOTIFICATION-TYPE SEVERE: A firmware mismatch error exists. | 1.3.6.1.4.1.318.0.773 | |
| upsFirmwareMismatchCleared NOTIFICATION-TYPE INFORMATIONAL: A firmware mismatch error no longer exists. | 1.3.6.1.4.1.318.0.774 | |
| upsOscillatorFailed NOTIFICATION-TYPE SEVERE: An oscillator error exists. | 1.3.6.1.4.1.318.0.775 | |
| upsOscillatorFailedCleared NOTIFICATION-TYPE INFORMATIONAL: An oscillator error no longer exists. | 1.3.6.1.4.1.318.0.776 | |
| upsOnBatteryDueToFault NOTIFICATION-TYPE SEVERE: The UPS is on battery due to an error. Symmetra UPSes: Intelligence module has reported being in self-test for too long. When this happens, the UPS is not usually in self-test, but the batteries are draining slowly. If left uncorrected, the batteries will become depleted and the UPS will not be able to turn on. If UPS has at least N+1 redundancy, check power modules one by one to determine which keeps the UPS in self-test. Once identified, replace the module. | 1.3.6.1.4.1.318.0.777 | |
| upsOnBatteryDueToFaultCleared NOTIFICATION-TYPE INFORMATIONAL: The UPS is no longer on battery due to an error. | 1.3.6.1.4.1.318.0.778 | |
| pcnsCriticalEventActive NOTIFICATION-TYPE SEVERE: PowerChute Network Shutdown has begun a safe shutdown of the host. | 1.3.6.1.4.1.318.0.779 | |
| pcnsCriticalEventResolved NOTIFICATION-TYPE INFORMATIONAL: PowerChute Network Shutdown critical event resolved. Safe shutdown will continue. | 1.3.6.1.4.1.318.0.780 | |
| pcnsNetworkComsLost NOTIFICATION-TYPE SEVERE: PowerChute cannot communicate with NMC | 1.3.6.1.4.1.318.0.781 | |
| pcnsNetworkComsLostResolved NOTIFICATION-TYPE INFORMATIONAL: PowerChute can communicate with NMC again. | 1.3.6.1.4.1.318.0.782 | |
| pcnsNMCComsLost NOTIFICATION-TYPE SEVERE: NMC cannot communicate with UPS. | 1.3.6.1.4.1.318.0.783 | |
| pcnsNMCComsLostResolved NOTIFICATION-TYPE INFORMATIONAL: NMC can communicate with UPS again. | 1.3.6.1.4.1.318.0.784 | |
| pcnsTest NOTIFICATION-TYPE INFORMATIONAL: PowerChute has sent a test trap. | 1.3.6.1.4.1.318.0.785 | |
| pcnsUpdateAvailable NOTIFICATION-TYPE INFORMATIONAL: PowerChute has detected that a newer version is available. | 1.3.6.1.4.1.318.0.786 | |
| temporaryBypass NOTIFICATION-TYPE WARNING: UPS on temporary bypass | 1.3.6.1.4.1.318.0.787 | |
| pcbeCriticalEventActive NOTIFICATION-TYPE SEVERE: PowerChute Business Edition has begun a safe shutdown of the host. | 1.3.6.1.4.1.318.0.790 | |
| pcbeCriticalEventResolved NOTIFICATION-TYPE INFORMATIONAL: PowerChute Business Edition critical event resolved. Safe shutdown will continue. | 1.3.6.1.4.1.318.0.791 | |
| pcbeComsLost NOTIFICATION-TYPE SEVERE: PowerChute cannot communicate with UPS | 1.3.6.1.4.1.318.0.792 | |
| pcbeComsLostResolved NOTIFICATION-TYPE INFORMATIONAL: PowerChute can communicate with UPS again. | 1.3.6.1.4.1.318.0.793 | |
| pcbeTest NOTIFICATION-TYPE INFORMATIONAL: PowerChute has sent a test trap. | 1.3.6.1.4.1.318.0.794 | |
| pcbeUpdateAvailable NOTIFICATION-TYPE INFORMATIONAL: PowerChute has detected that a newer version is available. | 1.3.6.1.4.1.318.0.795 | |
| pmmCriticalCondition NOTIFICATION-TYPE SEVERE: A PMM critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message. | 1.3.6.1.4.1.318.0.796 | |
| pmmCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A PMM critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message. | 1.3.6.1.4.1.318.0.797 | |
| pmmWarningCondition NOTIFICATION-TYPE WARNING: A PMM warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message. | 1.3.6.1.4.1.318.0.798 | |
| pmmWarningConditionCleared NOTIFICATION-TYPE WARNING: A PMM warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message. | 1.3.6.1.4.1.318.0.799 | |
| pmmInformationalCondition NOTIFICATION-TYPE INFORMATIONAL: A PMM informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message. | 1.3.6.1.4.1.318.0.800 | |
| pmmInformationalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A PMM informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message. | 1.3.6.1.4.1.318.0.801 | |
| upsInputContactOutputRelayFault NOTIFICATION-TYPE SEVERE: A fault exists in the UPS input contact / output relay hardware. | 1.3.6.1.4.1.318.0.802 | |
| upsInputContactOutputRelayFaultCleared NOTIFICATION-TYPE INFORMATIONAL: Fault no longer exists in the UPS input contact / output relay hardware. | 1.3.6.1.4.1.318.0.803 | |
| upsAirFilterWarning NOTIFICATION-TYPE WARNING: Air filter requires service. | 1.3.6.1.4.1.318.0.804 | |
| upsAirFilterWarningCleared NOTIFICATION-TYPE INFORMATIONAL: Air filter no longer requires service. | 1.3.6.1.4.1.318.0.805 | |
| upsBatteryPackIncompatible NOTIFICATION-TYPE SEVERE: Incompatible battery pack. | 1.3.6.1.4.1.318.0.806 | |
| upsBatteryPackIncompatibleCleared NOTIFICATION-TYPE INFORMATIONAL: Incompatible battery pack no longer present. | 1.3.6.1.4.1.318.0.807 | |
| upsInputContactAbnormal NOTIFICATION-TYPE WARNING: UPS input contact is in the abnormal state. | 1.3.6.1.4.1.318.0.808 | |
| upsInputContactAbnormalCleared NOTIFICATION-TYPE INFORMATIONAL: UPS input contact has returned to its normal state. | 1.3.6.1.4.1.318.0.809 | |
| upsOutputRelayAbnormal NOTIFICATION-TYPE WARNING: A UPS output relay has switched to the abnormal state. | 1.3.6.1.4.1.318.0.810 | |
| upsOutputRelayAbnormalCleared NOTIFICATION-TYPE INFORMATIONAL: A UPS output relay has returned to its normal state. | 1.3.6.1.4.1.318.0.811 | |
| ePDUCriticalCondition NOTIFICATION-TYPE SEVERE: A EPDU critical condition has been detected. | 1.3.6.1.4.1.318.0.812 | |
| ePDUCriticalConditionCleared NOTIFICATION-TYPE INFORMATIONAL: A EPDU critical condition has been cleared. | 1.3.6.1.4.1.318.0.813 | |
| ePDUWarningCondition NOTIFICATION-TYPE SEVERE: A Easy PDU warning condition has been detected. | 1.3.6.1.4.1.318.0.814 | |
| ePDUWarningConditionCleared NOTIFICATION-TYPE SEVERE: A Easy PDU warning condition has been cleared. | 1.3.6.1.4.1.318.0.815 |