PowerNet-MIB

Registered at
1.3.6.1.4.1.318
Namespace
apc
Source file
PowerNet-MIB
Digest
sha256:ffacfa38ca27398ba4a94e9cfa28bcbf6c126dd806c0630149213f99d7f865dd

Imports

FromSymbols
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

PowerNet-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AirIRG2RDType2IOState
type
AirIRSCCapacityControlType
type
AirIRSCConfigType
type
AirIRSCFanSpeedControl
type
AirIRSCFanSpeedPreference
type
AirIRmActivityState
type
AirIRmAlarmState
type
AirIRmControlState
type
AirIRmStopState
type
Rpdu2OutletPhaseLayoutType
type

Objects

NameOIDSyntaxAccessStatus
apc
OBJECT-IDENTITY
1.3.6.1.4.1.318
products
OBJECT-IDENTITY
1.3.6.1.4.1.318.1
hardware
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1
ups
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1
upsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.1
upsBasicIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.1.1
upsBasicIdentModel
OBJECT-TYPE
The UPS model name (e.g. 'APC Smart-UPS 600').
1.3.6.1.4.1.318.1.1.1.1.1.1DisplayStringread-onlymandatory
upsBasicIdentName
OBJECT-TYPE
An 8 byte ID string identifying the UPS. This object can be set by the administrator. For GVS, GPX and GVL products, this string can be up to 32 bytes.
1.3.6.1.4.1.318.1.1.1.1.1.2DisplayStringread-writemandatory
upsBasicIdentFamilyName
OBJECT-TYPE
The UPS model family name for the product.
1.3.6.1.4.1.318.1.1.1.1.1.3DisplayStringread-onlymandatory
upsBasicIdentModelType
OBJECT-TYPE
The detailed model information of the system.
1.3.6.1.4.1.318.1.1.1.1.1.4DisplayStringread-onlymandatory
upsAdvIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.1.2
upsAdvIdentFirmwareRevision
OBJECT-TYPE
The firmware revision of the UPS system's microprocessor.
1.3.6.1.4.1.318.1.1.1.1.2.1DisplayStringread-onlymandatory
upsAdvIdentDateOfManufacture
OBJECT-TYPE
The date when the UPS was manufactured in mm/dd/yy (or yyyy) format.
1.3.6.1.4.1.318.1.1.1.1.2.2DisplayStringread-onlymandatory
upsAdvIdentSerialNumber
OBJECT-TYPE
An 8-character string (12-character in case of 3 phase UPS) identifying the serial number of the UPS internal microprocessor. This number is set at the factory. NOTE: This number does NOT correspond to the serial number on the rear of the UPS.
1.3.6.1.4.1.318.1.1.1.1.2.3DisplayStringread-onlymandatory
upsAdvIdentFirmwareRevision2
OBJECT-TYPE
The firmware revision of a UPS system co-microprocessor.
1.3.6.1.4.1.318.1.1.1.1.2.4DisplayStringread-onlymandatory
upsAdvIdentSkuNumber
OBJECT-TYPE
The SKU number of a UPS system.
1.3.6.1.4.1.318.1.1.1.1.2.5DisplayStringread-onlymandatory
upsAdvIdentHardwareRevision
OBJECT-TYPE
The hardware revision of a UPS system.
1.3.6.1.4.1.318.1.1.1.1.2.6DisplayStringread-onlymandatory
upsAdvIdentUpsPhaseConfigType
OBJECT-TYPE
The type definition, based on phase configuration. 1 - Unknown 2 - 3 phase in/out 3 - 1 phase in/out 4 - 3 phase in/1 phase out
1.3.6.1.4.1.318.1.1.1.1.2.7INTEGER {unknown(1), threePhaseInOut(2), onePhaseInOut(3), threePhaseInOneOut(4)}read-onlymandatory
upsAdvEnergyStorageType
OBJECT-TYPE
The energy storage type connected to the UPS. It states battery type and battery chemistry. 1 - Unknown 2 - VRLA or wet cells 3 - NiCd batteries 4 - Lithium-ion batteries 5 - No energy storage 6 - Flywheel 7 - Ultracaps
1.3.6.1.4.1.318.1.1.1.1.2.8INTEGER {unknown(1), vrlaOrWetCells(2), niCdBatteries(3), liIonBatteries(4), noEnergyStorage(5), flywheel(6), ultracaps(7)}read-onlymandatory
upsBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.2
upsBasicBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.2.1
upsBasicBatteryStatus
OBJECT-TYPE
The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime. A batteryInFaultCondition(4)value indicates that a battery installed has an internal error condition.
1.3.6.1.4.1.318.1.1.1.2.1.1INTEGER {unknown(1), batteryNormal(2), batteryLow(3), batteryInFaultCondition(4)}read-onlymandatory
upsBasicBatteryTimeOnBattery
OBJECT-TYPE
The elapsed time since the UPS has switched to battery power.
1.3.6.1.4.1.318.1.1.1.2.1.2TimeTicksread-onlymandatory
upsBasicBatteryLastReplaceDate
OBJECT-TYPE
The date when the UPS system's batteries were last replaced in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value is originally set in the factory. When the UPS batteries are replaced, this value should be reset by the administrator. For Symmetra PX 250/500 this OID is read only and is configurable in the local display only.
1.3.6.1.4.1.318.1.1.1.2.1.3DisplayStringread-writemandatory
upsAdvBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.2.2
upsAdvBatteryCapacity
OBJECT-TYPE
The remaining battery capacity expressed in percent of full capacity.
1.3.6.1.4.1.318.1.1.1.2.2.1Gaugeread-onlymandatory
upsAdvBatteryTemperature
OBJECT-TYPE
The current internal UPS temperature expressed in Celsius. Temperatures below zero read as 0. Consider using upsHighPrecExtdBatteryTemperature instead.
1.3.6.1.4.1.318.1.1.1.2.2.2Gaugeread-onlymandatory
upsAdvBatteryRunTimeRemaining
OBJECT-TYPE
The UPS battery run time remaining before battery exhaustion.
1.3.6.1.4.1.318.1.1.1.2.2.3TimeTicksread-onlymandatory
upsAdvBatteryReplaceIndicator
OBJECT-TYPE
Indicates whether the UPS batteries need replacing.
1.3.6.1.4.1.318.1.1.1.2.2.4INTEGER {noBatteryNeedsReplacing(1), batteryNeedsReplacing(2)}read-onlymandatory
upsAdvBatteryNumOfBattPacks
OBJECT-TYPE
The number of external battery packs connected to the UPS. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.318.1.1.1.2.2.5INTEGERread-onlymandatory
upsAdvBatteryNumOfBadBattPacks
OBJECT-TYPE
The number of external battery packs connected to the UPS that are defective. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME.
1.3.6.1.4.1.318.1.1.1.2.2.6INTEGERread-onlymandatory
upsAdvBatteryNominalVoltage
OBJECT-TYPE
The nominal battery voltage in Volts.
1.3.6.1.4.1.318.1.1.1.2.2.7INTEGERread-onlymandatory
upsAdvBatteryActualVoltage
OBJECT-TYPE
The actual battery bus voltage in Volts.
1.3.6.1.4.1.318.1.1.1.2.2.8INTEGERread-onlymandatory
upsAdvBatteryCurrent
OBJECT-TYPE
The battery current in Amps.
1.3.6.1.4.1.318.1.1.1.2.2.9INTEGERread-onlymandatory
upsAdvTotalDCCurrent
OBJECT-TYPE
The total DC current in Amps.
1.3.6.1.4.1.318.1.1.1.2.2.10INTEGERread-onlymandatory
upsAdvBatteryFullCapacity
OBJECT-TYPE
The full chargeable capacity of the battery which is expressed in percentage.
1.3.6.1.4.1.318.1.1.1.2.2.11INTEGERread-onlymandatory
upsAdvBatteryActualVoltageTable
OBJECT-TYPE
A list of battery table entries. The number of battery frames present in UPS.
1.3.6.1.4.1.318.1.1.1.2.2.12not-accessiblemandatory
upsAdvBatteryActualVoltageEntry
OBJECT-TYPE
Information applicable to each of the Battery frames.
1.3.6.1.4.1.318.1.1.1.2.2.12.1not-accessiblemandatory
upsAdvBatteryActualVoltageTableIndex
OBJECT-TYPE
The Battery Frame identifier. Battery Frame index.
1.3.6.1.4.1.318.1.1.1.2.2.12.1.1INTEGERread-onlymandatory
upsAdvBatteryActualVoltagePolarity
OBJECT-TYPE
The selected Battery Voltage Polarity. 0 indicates positive polarity. 1 indicates negative polarity.
1.3.6.1.4.1.318.1.1.1.2.2.12.1.2INTEGER {positive(0), negative(1)}read-onlymandatory
upsAdvBatteryFrameActualVoltage
OBJECT-TYPE
The actual battery bus voltage in Volts.
1.3.6.1.4.1.318.1.1.1.2.2.12.1.3INTEGERread-onlymandatory
upsAdvTotalDCCurrentTable
OBJECT-TYPE
A list of Battery Frame table entries. The number of entries is given by the value of Number of Battery Frames.
1.3.6.1.4.1.318.1.1.1.2.2.13not-accessiblemandatory
upsAdvTotalDCCurrentEntry
OBJECT-TYPE
An entry containing information applicable to a particular Battery Frame.
1.3.6.1.4.1.318.1.1.1.2.2.13.1not-accessiblemandatory
upsAdvTotalDCCurrentTableIndex
OBJECT-TYPE
The Battery Frame identifier. Total DC Current Table Index.
1.3.6.1.4.1.318.1.1.1.2.2.13.1.1INTEGERread-onlymandatory
upsAdvTotalDCCurrentPolarity
OBJECT-TYPE
The selected Battery Current Polarity. 0 indicates positive polarity. 1 indicates negative polarity.
1.3.6.1.4.1.318.1.1.1.2.2.13.1.2INTEGER {positive(0), negative(1)}read-onlymandatory
upsAdvTotalFrameDCCurrent
OBJECT-TYPE
The Total DC Current of battery in Amperes.
1.3.6.1.4.1.318.1.1.1.2.2.13.1.3INTEGERread-onlymandatory
upsAdvBatteryCurrentTable
OBJECT-TYPE
A list of Battery Frame table entries. The number of entries is given by number of Battery frames present.
1.3.6.1.4.1.318.1.1.1.2.2.14not-accessiblemandatory
upsAdvBatteryCurrentEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery frame.
1.3.6.1.4.1.318.1.1.1.2.2.14.1not-accessiblemandatory
upsAdvBatteryCurrentTableIndex
OBJECT-TYPE
The Battery Frame identifier. Battery Current Table Index.
1.3.6.1.4.1.318.1.1.1.2.2.14.1.1INTEGERread-onlymandatory
upsAdvBatteryCurrentIndex
OBJECT-TYPE
The battery frame identifier.
1.3.6.1.4.1.318.1.1.1.2.2.14.1.2INTEGERread-onlymandatory
upsAdvBatteryCurrentPolarity
OBJECT-TYPE
The selected Battery current polarity. 0 indicates positive polarity. 1 indicates negative polarity
1.3.6.1.4.1.318.1.1.1.2.2.14.1.3INTEGER {positive(0), negative(1)}read-onlymandatory
upsAdvBatteryFrameCurrent
OBJECT-TYPE
The Battery current measured in Amperes
1.3.6.1.4.1.318.1.1.1.2.2.14.1.4INTEGERread-onlymandatory
upsAdvBatteryEstimatedChargeTime
OBJECT-TYPE
The estimated remaining time required to charge the UPS to a full state of charge.
1.3.6.1.4.1.318.1.1.1.2.2.15TimeTicksread-onlymandatory
upsAdvBatteryPower
OBJECT-TYPE
The measured battery power in kW.
1.3.6.1.4.1.318.1.1.1.2.2.16INTEGERread-onlymandatory
upsAdvBatteryChargerStatus
OBJECT-TYPE
The status of the battery charger. If the UPS is unable to find the state of charger, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.2.2.17INTEGER {unknown(1), ok(2), inFaultCondition(3), floatCharging(4), boostCharging(5), resting(6), notCharging(7), equalizationCharging(8), testInProgress(9), cyclicFloatCharging(10)}read-onlymandatory
upsAdvBatteryInternalSKU
OBJECT-TYPE
The SKU of the internal battery.
1.3.6.1.4.1.318.1.1.1.2.2.19DisplayStringread-onlymandatory
upsAdvBatteryExternalSKU
OBJECT-TYPE
The SKU of the external battery.
1.3.6.1.4.1.318.1.1.1.2.2.20DisplayStringread-onlymandatory
upsAdvBatteryRecommendedReplaceDate
OBJECT-TYPE
The recommended replacement date for the battery based on the UPS internal battery life algorithm.
1.3.6.1.4.1.318.1.1.1.2.2.21DisplayStringread-onlymandatory
upsAdvBatteryNominalBackupTime
OBJECT-TYPE
Defines the runtime of the user supplied battery in minutes, when battery is new.
1.3.6.1.4.1.318.1.1.1.2.2.22INTEGERread-onlymandatory
upsAdvBatteryCondition
OBJECT-TYPE
Health of the battries based on the battery test.
1.3.6.1.4.1.318.1.1.1.2.2.23INTEGER {unknown(1), ok(2), weak(3), poor(4)}read-onlymandatory
upsAdvBatteryChargingCurrentRestricted
OBJECT-TYPE
Indicates whether battery charging current is restricted or not. The value of yes(1) indicates that battery charging current is restricted . The value of no(2) indicates that battery charging current is not restricted.
1.3.6.1.4.1.318.1.1.1.2.2.24INTEGER {yes(1), no(2)}read-onlymandatory
upsAdvBatteryTotalCapacity
OBJECT-TYPE
The actual available battery capacity of the system expressed in ampere hours (Ah). The value is updated continuously, for example when battery breakers are opened or closed, or when battery strings/battery blocks are added or removed.
1.3.6.1.4.1.318.1.1.1.2.2.25Gaugeread-onlymandatory
upsAdvBatteryFuseStatus
OBJECT-TYPE
If battery system has one common fuse for the battery system, the status is given by this value. 1 = Fuse Open 2 = Fuse Ok 3 = Not present
1.3.6.1.4.1.318.1.1.1.2.2.26INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)}read-onlymandatory
upsAdvBatteryBreakerStatus
OBJECT-TYPE
The value indicates the aggregated status of the battery breakers in the system. disconnected(1) indicates none of the battery breakers are closed, and the battery system is disconnected closed(2) indicates at least one of the battery breakers in the system is closed notPresent(3) if not present
1.3.6.1.4.1.318.1.1.1.2.2.27INTEGER {disconnected(1), closed(2), notPresent(3)}read-onlymandatory
upsAdvBatteryWiringConfiguration
OBJECT-TYPE
The value indicates the wiring configuration, whether the battery is 2-wire or 3-wire. If it's a 3-wire battery system, the system can have 2 voltages and currents per cabinet. 1 = 2-wire (a non-split battery) 2 = 3-wire (a split battery)
1.3.6.1.4.1.318.1.1.1.2.2.28INTEGER {twoWire(1), threeWire(2)}read-onlymandatory
upsHighPrecBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.2.3
upsHighPrecBatteryCapacity
OBJECT-TYPE
The remaining battery capacity expressed in tenths of percent of full capacity.
1.3.6.1.4.1.318.1.1.1.2.3.1Gaugeread-onlymandatory
upsHighPrecBatteryTemperature
OBJECT-TYPE
The current internal UPS temperature expressed in tenths of degrees Celsius. Temperatures below zero read as 0. Consider using upsHighPrecExtdBatteryTemperature instead.
1.3.6.1.4.1.318.1.1.1.2.3.2Gaugeread-onlymandatory
upsHighPrecBatteryNominalVoltage
OBJECT-TYPE
The nominal battery voltage in tenths of Volts.
1.3.6.1.4.1.318.1.1.1.2.3.3INTEGERread-onlymandatory
upsHighPrecBatteryActualVoltage
OBJECT-TYPE
The actual battery bus voltage in tenths of Volts.
1.3.6.1.4.1.318.1.1.1.2.3.4INTEGERread-onlymandatory
upsHighPrecBatteryCurrent
OBJECT-TYPE
The battery current in tenths of Amps.
1.3.6.1.4.1.318.1.1.1.2.3.5INTEGERread-onlymandatory
upsHighPrecTotalDCCurrent
OBJECT-TYPE
The total DC current in tenths of Amps.
1.3.6.1.4.1.318.1.1.1.2.3.6INTEGERread-onlymandatory
upsHighPrecBatteryActualVoltageTable
OBJECT-TYPE
A list of Battery frame table entries. The number of entries is given by the number of Battery frames.
1.3.6.1.4.1.318.1.1.1.2.3.7not-accessiblemandatory
upsHighPrecBatteryActualVoltageEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery frame.
1.3.6.1.4.1.318.1.1.1.2.3.7.1not-accessiblemandatory
upsHighPrecBatteryActualVoltageTableIndex
OBJECT-TYPE
The Battery Frame identifier. High Precision Actual Voltage Table Index.
1.3.6.1.4.1.318.1.1.1.2.3.7.1.1INTEGERread-onlymandatory
upsHighPrecBatteryActualVoltagePolarity
OBJECT-TYPE
The selected Battery Voltage polarity. 0 indicates positive polarity. 1 indicates negative polarity.
1.3.6.1.4.1.318.1.1.1.2.3.7.1.2INTEGER {positive(0), negative(1)}read-onlymandatory
upsHighPrecBatteryVoltage
OBJECT-TYPE
The actual battery bus voltage expressed as tenths of Volts.
1.3.6.1.4.1.318.1.1.1.2.3.7.1.3INTEGERread-onlymandatory
upsHighPrecTotalDCCurrentTable
OBJECT-TYPE
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
1.3.6.1.4.1.318.1.1.1.2.3.8not-accessiblemandatory
upsHighPrecTotalDCCurrentEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery frame.
1.3.6.1.4.1.318.1.1.1.2.3.8.1not-accessiblemandatory
upsHighPrecTotalDCCurrentTableIndex
OBJECT-TYPE
The Battery Frame identifier. High precision Total DC Current index.
1.3.6.1.4.1.318.1.1.1.2.3.8.1.1INTEGERread-onlymandatory
upsHighPrecTotalDCCurrentPolarity
OBJECT-TYPE
The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity.
1.3.6.1.4.1.318.1.1.1.2.3.8.1.2INTEGER {positive(0), negative(1)}read-onlymandatory
upsHighPrecTotalDCFrameCurrent
OBJECT-TYPE
The total DC current in tenths of Amperes.
1.3.6.1.4.1.318.1.1.1.2.3.8.1.3INTEGERread-onlymandatory
upsHighPrecBatteryCurrentTable
OBJECT-TYPE
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
1.3.6.1.4.1.318.1.1.1.2.3.9not-accessiblemandatory
upsHighPrecBatteryCurrentEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery frame.
1.3.6.1.4.1.318.1.1.1.2.3.9.1not-accessiblemandatory
upsHighPrecBatteryCurrentTableIndex
OBJECT-TYPE
The Battery frame identifier. Battery Frame index.
1.3.6.1.4.1.318.1.1.1.2.3.9.1.1INTEGERread-onlymandatory
upsHighPrecBatteryCurrentIndex
OBJECT-TYPE
The Battery frame identifier. Battery Index for each frame.
1.3.6.1.4.1.318.1.1.1.2.3.9.1.2INTEGERread-onlymandatory
upsHighPrecBatteryCurrentPolarity
OBJECT-TYPE
The selected Battery Current polarity. 0 indicates positive polarity. 1 indicates negative polarity.
1.3.6.1.4.1.318.1.1.1.2.3.9.1.3INTEGER {positive(0), negative(1)}read-onlymandatory
upsHighPrecBatteryFrameCurrent
OBJECT-TYPE
The Battery current in tenths of Amperes.
1.3.6.1.4.1.318.1.1.1.2.3.9.1.4INTEGERread-onlymandatory
upsHighPrecBatteryPacks
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.2.3.10
upsHighPrecBatteryPackTableSize
OBJECT-TYPE
The number of entries in the upsHighPrecBatteryPacks.
1.3.6.1.4.1.318.1.1.1.2.3.10.1INTEGERread-onlymandatory
upsHighPrecBatteryPackTable
OBJECT-TYPE
A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present.
1.3.6.1.4.1.318.1.1.1.2.3.10.2not-accessiblemandatory
upsHighPrecBatteryPackEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery pack.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1not-accessiblemandatory
upsHighPrecBatteryPackIndex
OBJECT-TYPE
The battery pack identifier.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1INTEGERread-onlymandatory
upsHighPrecBatteryCartridgeIndex
OBJECT-TYPE
The battery cartridge identifier.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2INTEGERread-onlymandatory
upsHighPrecBatteryPackFirmwareRevision
OBJECT-TYPE
The battery pack firmware revision.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.3DisplayStringread-onlymandatory
upsHighPrecBatteryPackSerialNumber
OBJECT-TYPE
The battery pack serial number.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4DisplayStringread-onlymandatory
upsHighPrecBatteryPackTemperature
OBJECT-TYPE
The battery pack temperature measured in 10ths of degree Celcius
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5INTEGERread-onlymandatory
upsHighPrecBatteryPackStatus
OBJECT-TYPE
The battery status for the pack only. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 GeneralError bit 9 Communication bit 10 DisconnectedFrame bit 11 FirmwareMismatch
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.6OCTET STRINGread-onlymandatory
upsHighPrecBatteryPackCartridgeHealth
OBJECT-TYPE
The battery cartridge health. bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement cartridge bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order replacement cartridge bit 4 Battery lifetime exceeded acknowledged, replace battery bit 5 Battery measured lifetime near end, order replacement cartridge bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7OCTET STRINGread-onlymandatory
upsHighPrecBatteryPackCartridgeReplaceDate
OBJECT-TYPE
The battery cartridge estimated battery replace date.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8DisplayStringread-onlymandatory
upsHighPrecBatteryPackCartridgeInstallDate
OBJECT-TYPE
The battery cartridge install date.
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.9DisplayStringread-writemandatory
upsHighPrecBatteryPackCartridgeStatus
OBJECT-TYPE
The battery cartridge status. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 GeneralError bit 9 Communication bit 10 DisconnectedFrame bit 11 FirmwareMismatch
1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10OCTET STRINGread-onlymandatory
upsHighPrecBatteryPackOnlyTableSize
OBJECT-TYPE
The number of entries in the upsHighPrecBatteryPacks.
1.3.6.1.4.1.318.1.1.1.2.3.10.3INTEGERread-onlymandatory
upsHighPrecBatteryPackOnlyTable
OBJECT-TYPE
A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present.
1.3.6.1.4.1.318.1.1.1.2.3.10.4not-accessiblemandatory
upsHighPrecBatteryPackOnlyEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery pack.
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1not-accessiblemandatory
upsHighPrecBatteryPackOnlyIndex
OBJECT-TYPE
The battery pack identifier.
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.1INTEGERread-onlymandatory
upsHighPrecBatteryPackOnlyFirmwareRevision
OBJECT-TYPE
The battery pack firmware revision.
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.2DisplayStringread-onlymandatory
upsHighPrecBatteryPackOnlySerialNumber
OBJECT-TYPE
The battery pack serial number.
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.3DisplayStringread-onlymandatory
upsHighPrecBatteryPackOnlyTemperature
OBJECT-TYPE
The battery pack temperature measured in 10ths of degree Celcius
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.4INTEGERread-onlymandatory
upsHighPrecBatteryPackOnlyStatus
OBJECT-TYPE
The battery status for the pack only. bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 GeneralError bit 9 Communication bit 10 DisconnectedFrame bit 11 FirmwareMismatch
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.5OCTET STRINGread-onlymandatory
upsHighPrecBatteryPackOnlyHealth
OBJECT-TYPE
The battery pack health. bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement pack bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order replacement pack bit 4 Battery lifetime exceeded acknowledged, replace battery bit 5 Battery measured lifetime near end, order replacement pack bit 6 Battery measured lifetime near end acknowledged, order replacement pack
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.6OCTET STRINGread-onlymandatory
upsHighPrecBatteryPackOnlyReplaceDate
OBJECT-TYPE
The battery pack estimated battery replace date.
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.7DisplayStringread-onlymandatory
upsHighPrecBatteryPackOnlyInstallDate
OBJECT-TYPE
The battery pack install date.
1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.8DisplayStringread-writemandatory
upsHighPrecBatteryHealth
OBJECT-TYPE
The battery health. Bit 0 Battery life okay Bit 1 Battery life near end, order battery cartridge Bit 2 Battery life exceeded, replace battery cartridge Bit 3 Battery life near end acknowledged, order battery cartridge Bit 4 Battery life exceeded acknowledged, replace battery cartridge Bit 5 Battery measured life near end, order battery cartridge Bit 6 Battery measured life near end acknowledged, order battery cartridge
1.3.6.1.4.1.318.1.1.1.2.3.11OCTET STRINGread-onlymandatory
upsHighPrecActivePower
OBJECT-TYPE
Active Power of Battery in tenths of kW
1.3.6.1.4.1.318.1.1.1.2.3.12INTEGERread-onlymandatory
upsHighPrecExtdBatteryTemperature
OBJECT-TYPE
The current internal UPS temperature expressed in tenths of degrees Celsius. Can be negative.
1.3.6.1.4.1.318.1.1.1.2.3.13INTEGERread-onlymandatory
upsBatteryNumberOfCabinets
OBJECT-TYPE
The value indicates the number of battery cabinets in total, internal and external. If the UPS only has internal batteries, that number should be 1. If the UPS has external and internal, the number is 1 + number of external cabinets.
1.3.6.1.4.1.318.1.1.1.2.4INTEGERread-onlymandatory
upsBatteryCabinetTable
OBJECT-TYPE
Table of battery cabinets
1.3.6.1.4.1.318.1.1.1.2.5not-accessibleoptional
upsBatteryCabinetEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery cabinet.
1.3.6.1.4.1.318.1.1.1.2.5.1not-accessibleoptional
upsBatteryCabinetIndex
OBJECT-TYPE
The Battery Cabinet identifier. Battery Cabinet Table Index.
1.3.6.1.4.1.318.1.1.1.2.5.1.1INTEGERread-onlyoptional
upsBatteryCabinetLocalIndex
OBJECT-TYPE
The identification number for the actual battery cabinet in the system. 0 corresponds to the internal batteries 1 and higher corresponds to external battery cabinets
1.3.6.1.4.1.318.1.1.1.2.5.1.2INTEGERread-onlyoptional
upsBatteryCabinetWiringConfiguration
OBJECT-TYPE
The value indicates the wiring configuration, whether the battery is 2-wire or 3-wire. If it's a 3-wire battery system, the system can have two voltages and currents per cabinet. 1 = 2-wire (a non-split battery) 2 = 3-wire (a split battery)
1.3.6.1.4.1.318.1.1.1.2.5.1.3INTEGER {twoWire(1), threeWire(2)}read-onlyoptional
upsBatteryCabinetVoltagePolarity1
OBJECT-TYPE
The battery voltage. For a non-split battery, it is the full voltage. For a split battery, the value is the voltage for one side/half of the battery
1.3.6.1.4.1.318.1.1.1.2.5.1.4INTEGERread-onlyoptional
upsBatteryCabinetVoltagePolarity2
OBJECT-TYPE
The voltage for the second side/half of the battery in a split battery system. If it is not a split battery, this reports -1
1.3.6.1.4.1.318.1.1.1.2.5.1.5INTEGERread-onlyoptional
upsBatteryCabinetCurrentPolarity1
OBJECT-TYPE
The battery current. For a non-split battery, it is the full current. For a split battery, the value is the current for one side/half of the battery
1.3.6.1.4.1.318.1.1.1.2.5.1.6INTEGERread-onlyoptional
upsBatteryCabinetCurrentPolarity2
OBJECT-TYPE
The current for the second side/half of the battery in a split battery system. If it is not a split battery, this reports -1
1.3.6.1.4.1.318.1.1.1.2.5.1.7INTEGERread-onlyoptional
upsBatteryCabinetTemperature
OBJECT-TYPE
The measured temperature of the battery cabinet in tenths of degrees Celcius
1.3.6.1.4.1.318.1.1.1.2.5.1.8INTEGERread-onlyoptional
upsBatteryCabinetMaxTemperature
OBJECT-TYPE
The highest temperature measured for the battery in the battery cabinet in tenths of degrees Celcius. If there are multiple sensors in the battery cabinet, it is the selected highest actual value of measured temperatures. If there is battery string information, it is the highest actual battery string temperature value.
1.3.6.1.4.1.318.1.1.1.2.5.1.9INTEGERread-onlyoptional
upsBatteryCabinetMinTemperature
OBJECT-TYPE
The lowest temperature measured for the battery in the battery cabinet in tenths of degrees Celcius. If there are multiple sensors in the battery cabinet, it is the selected lowest actual value of measured temperatures. If there is string information, it is the lowest actual battery string temperature value.
1.3.6.1.4.1.318.1.1.1.2.5.1.10INTEGERread-onlyoptional
upsBatteryCabinetAverageTemperature
OBJECT-TYPE
The average temperature for all the battery sensors in the battery cabinet and for the battery strings, if battery strings are present. Measured in tenths of degrees Celcius.
1.3.6.1.4.1.318.1.1.1.2.5.1.11INTEGERread-onlyoptional
upsBatteryCabinetFuse
OBJECT-TYPE
If the battery cabinet has a common fuse, the status is given by this value. 1 = Fuse open 2 = Fuse OK 3 = Not present
1.3.6.1.4.1.318.1.1.1.2.5.1.12INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)}read-onlyoptional
upsBatteryCabinetBreaker
OBJECT-TYPE
The value indicates the battery cabinet breaker status. Reports 1 if no breaker is present. 1 = No breaker 2 = Unknown 3 = Breaker open 4 = Breaker closed
1.3.6.1.4.1.318.1.1.1.2.5.1.13INTEGER {noBreaker(1), unknown(2), breakerOpen(3), breakerClosed(4)}read-onlyoptional
upsBatteryCabinetNumberOfStrings
OBJECT-TYPE
The number of battery strings in the battery cabinet. The value can be 0, meaning that no additional information on the battery string is available. 1 and higher means data in the table is provided.
1.3.6.1.4.1.318.1.1.1.2.5.1.14INTEGERread-onlyoptional
upsBatteryCabinetNumberOfVerticalPositions
OBJECT-TYPE
The number of vertical levels or shelves for battery blocks/modules. The levels are indexed from the bottom up
1.3.6.1.4.1.318.1.1.1.2.5.1.15INTEGERread-onlyoptional
upsBatteryCabinetNumberOfHorizontalPositions
OBJECT-TYPE
The number of horizontal positions for battery blocks/modules. The levels are indexed from left to right
1.3.6.1.4.1.318.1.1.1.2.5.1.16INTEGERread-onlyoptional
upsBatteryCabStringTable
OBJECT-TYPE
Table of battery strings in the complete battery solution
1.3.6.1.4.1.318.1.1.1.2.6not-accessibleoptional
upsBatteryCabStringEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery string in the battery cabinet.
1.3.6.1.4.1.318.1.1.1.2.6.1not-accessibleoptional
upsBatteryCabStringIndex
OBJECT-TYPE
The battery cabinet string identifier. Battery cabinet string or halfstring table index.
1.3.6.1.4.1.318.1.1.1.2.6.1.1INTEGERread-onlyoptional
upsBatteryCabStringCabReference
OBJECT-TYPE
Reference to the global battery cabinet index where the battery string is placed.
1.3.6.1.4.1.318.1.1.1.2.6.1.2INTEGERread-onlyoptional
upsBatteryCabStringLocalIndex
OBJECT-TYPE
Local battery string identification index in the actual battery cabinet (E.g. String 2 in cabinet)
1.3.6.1.4.1.318.1.1.1.2.6.1.3INTEGERread-onlyoptional
upsBatteryCabStringCurrent
OBJECT-TYPE
The current in a battery string or battery halfstring, in tenths of Amps.
1.3.6.1.4.1.318.1.1.1.2.6.1.4INTEGERread-onlyoptional
upsBatteryCabStringAverageTemperature
OBJECT-TYPE
Temperature of the battery string or the average of the aggregated temperature of each battery block/module (in tenths of degrees Celcius).
1.3.6.1.4.1.318.1.1.1.2.6.1.5INTEGERread-onlyoptional
upsBatteryCabStringMaxTemperature
OBJECT-TYPE
The actual highest battery temperature measurement for the battery blocks/modules (in tenths of degrees Celcius).
1.3.6.1.4.1.318.1.1.1.2.6.1.6INTEGERread-onlyoptional
upsBatteryCabStringMinTemperature
OBJECT-TYPE
The actual lowest battery temperature measurement for the battery blocks/modules (in tenths of degrees Celcius).
1.3.6.1.4.1.318.1.1.1.2.6.1.7INTEGERread-onlyoptional
upsBatteryCabStringFuseStatus
OBJECT-TYPE
If the battery string has a common fuse, the status is given by this value. 1 = Fuse open 2 = Fuse OK 3 = Not present
1.3.6.1.4.1.318.1.1.1.2.6.1.8INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)}read-onlyoptional
upsBatteryCabStringNumberOfBlocks
OBJECT-TYPE
The number of battery blocks/modules in a battery string. Can be 0, if no data is available in the table of individual battery blocks/cartridges
1.3.6.1.4.1.318.1.1.1.2.6.1.9INTEGERread-onlyoptional
upsBatteryCabBlockTable
OBJECT-TYPE
Table of battery blocks/modules in the complete battery solution.
1.3.6.1.4.1.318.1.1.1.2.7not-accessibleoptional
upsBatteryCabBlockEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery block in the battery cabinet.
1.3.6.1.4.1.318.1.1.1.2.7.1not-accessibleoptional
upsBatteryCabBlockIndex
OBJECT-TYPE
The battery cabinet block identifier. Global battery cabinet block table index.
1.3.6.1.4.1.318.1.1.1.2.7.1.1INTEGERread-onlyoptional
upsBatteryCabBlockStringReference
OBJECT-TYPE
Reference to the specific global battery string index
1.3.6.1.4.1.318.1.1.1.2.7.1.2INTEGERread-onlyoptional
upsBatteryCabBlockLocalIndex
OBJECT-TYPE
Local battery block/module identification index in the actual battery string (E.g. Battery block 3 in the battery string)
1.3.6.1.4.1.318.1.1.1.2.7.1.3INTEGERread-onlyoptional
upsBatteryCabBlockPresent
OBJECT-TYPE
Value indicates if battery block/module is present in the system. Typically battery modules are removable and battery blocks are static. Reports notAvailable(3) if data is not available
1.3.6.1.4.1.318.1.1.1.2.7.1.4INTEGER {present(1), notPresent(2), notAvailable(3)}read-onlyoptional
upsBatteryCabBlockType
OBJECT-TYPE
Text string value, showing the vendor and model of the battery in the battery block/module
1.3.6.1.4.1.318.1.1.1.2.7.1.5DisplayStringread-onlyoptional
upsBatteryCabBlockTemperature
OBJECT-TYPE
The temperature for the battery block/module in tenths of degrees Celcius. If multiple sensors are available it is the highest temperature in the battery block/module
1.3.6.1.4.1.318.1.1.1.2.7.1.6INTEGERread-onlyoptional
upsBatteryCabBlockFuseStatus
OBJECT-TYPE
If the battery module has a fuse, the status is given by this value. 1 = Fuse open 2 = Fuse OK 3 = Not present
1.3.6.1.4.1.318.1.1.1.2.7.1.7INTEGER {fuseOpen(1), fuseOk(2), notPresent(3)}read-onlyoptional
upsBatteryCabBlockVoltage
OBJECT-TYPE
The voltage of the battery block/module
1.3.6.1.4.1.318.1.1.1.2.7.1.8INTEGERread-onlyoptional
upsBatteryCabBlockNumberOfCells
OBJECT-TYPE
The number of cells in the battery block/module
1.3.6.1.4.1.318.1.1.1.2.7.1.9INTEGERread-onlyoptional
upsBatteryCabBlockVerticalPosition
OBJECT-TYPE
The vertical position of the battery block/module in the actual battery cabinet (E.g. 4, if it is the 4th shelf counting from the bottom)
1.3.6.1.4.1.318.1.1.1.2.7.1.10INTEGERread-onlyoptional
upsBatteryCabBlockHorizontalPosition
OBJECT-TYPE
The horizontal position of the battery block/module in the actual battery cabinet (E.g. 3, if it is the 3rd position counting from the left)
1.3.6.1.4.1.318.1.1.1.2.7.1.11INTEGERread-onlyoptional
upsBatteryCabBlockCellTable
OBJECT-TYPE
Table of battery cells in a battery block/module in the complete battery solution
1.3.6.1.4.1.318.1.1.1.2.8not-accessibleoptional
upsBatteryCabBlockCellEntry
OBJECT-TYPE
An entry containing information applicable to a particular battery cell inside the battery block.
1.3.6.1.4.1.318.1.1.1.2.8.1not-accessibleoptional
upsBatteryCabBlockCellIndex
OBJECT-TYPE
The battery block cell identifier. Global battery block cell table index.
1.3.6.1.4.1.318.1.1.1.2.8.1.1INTEGERread-onlyoptional
upsBatteryCabBlockCellReference
OBJECT-TYPE
Reference to the specific global battery block/module index.
1.3.6.1.4.1.318.1.1.1.2.8.1.2INTEGERread-onlyoptional
upsBatteryCabBlockCellLocalIndex
OBJECT-TYPE
Local battery block/module identification index in the actual battery block (E.g. battery cell 5 in the battery block)
1.3.6.1.4.1.318.1.1.1.2.8.1.3INTEGERread-onlyoptional
upsBatteryCabBlockCellVoltage
OBJECT-TYPE
The measured battery cell voltage
1.3.6.1.4.1.318.1.1.1.2.8.1.4INTEGERread-onlyoptional
upsBatteryCabBlockCellTemperature
OBJECT-TYPE
The temperature for the battery cell in tenths of degrees Celcius. If there is not a temperature sensor for each battery cell, then report -1 for those, which are not present.
1.3.6.1.4.1.318.1.1.1.2.8.1.5INTEGERread-onlyoptional
upsInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.3
upsBasicInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.3.1
upsBasicInputPhase
OBJECT-TYPE
The current AC input phase.
1.3.6.1.4.1.318.1.1.1.3.1.1INTEGERread-onlymandatory
upsAdvInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.3.2
upsAdvInputLineVoltage
OBJECT-TYPE
The current utility line voltage in VAC.
1.3.6.1.4.1.318.1.1.1.3.2.1Gaugeread-onlymandatory
upsAdvInputMaxLineVoltage
OBJECT-TYPE
The maximum utility line voltage in VAC over the previous 1 minute period.
1.3.6.1.4.1.318.1.1.1.3.2.2Gaugeread-onlymandatory
upsAdvInputMinLineVoltage
OBJECT-TYPE
The minimum utility line voltage in VAC over the previous 1 minute period.
1.3.6.1.4.1.318.1.1.1.3.2.3Gaugeread-onlymandatory
upsAdvInputFrequency
OBJECT-TYPE
The current input frequency to the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.3.2.4Gaugeread-onlymandatory
upsAdvInputLineFailCause
OBJECT-TYPE
The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: - noTransfer(1) -- if there is no transfer yet. - highLineVoltage(2) -- if the transfer to battery is caused by an over voltage greater than the high transfer voltage. - brownout(3) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - blackout(4) -- if the duration of the outage is greater than five seconds and the line voltage is between 40% of the rated output voltage and ground. - smallMomentarySag(5) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and the low transfer voltage. - deepMomentarySag(6) -- if the duration of the outage is less than five seconds and the line voltage is between 40% of the rated output voltage and ground. The variable is set to - smallMomentarySpike(7) -- if the line failure is caused by a rate of change of input voltage less than ten volts per cycle. - largeMomentarySpike(8) -- if the line failure is caused by a rate of change of input voltage greater than ten volts per cycle. - selfTest(9) -- if the UPS was commanded to do a self test. - rateOfVoltageChange(10) -- if the failure is due to the rate of change of the line voltage.
1.3.6.1.4.1.318.1.1.1.3.2.5INTEGER {noTransfer(1), highLineVoltage(2), brownout(3), blackout(4), smallMomentarySag(5), deepMomentarySag(6), smallMomentarySpike(7), largeMomentarySpike(8), selfTest(9), rateOfVoltageChange(10)}read-onlymandatory
upsAdvInputNominalFrequency
OBJECT-TYPE
The nominal input frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.3.2.6INTEGERread-onlymandatory
upsAdvInputNominalVoltage
OBJECT-TYPE
The nominal input voltage of the UPS system in VAC.
1.3.6.1.4.1.318.1.1.1.3.2.7INTEGERread-onlymandatory
upsAdvInputBypassNominalFrequency
OBJECT-TYPE
The nominal bypass input frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.3.2.8INTEGERread-onlymandatory
upsAdvInputBypassNominalVoltage
OBJECT-TYPE
The nominal bypass input voltage of the UPS system in VAC.
1.3.6.1.4.1.318.1.1.1.3.2.9INTEGERread-onlymandatory
upsAdvInputStatisticsTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs.
1.3.6.1.4.1.318.1.1.1.3.2.10not-accessiblemandatory
upsAdvInputStatisticsEntry
OBJECT-TYPE
An entry containing information applicable to a particular input.
1.3.6.1.4.1.318.1.1.1.3.2.10.1not-accessiblemandatory
upsAdvInputStatisticsIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.1INTEGERread-onlymandatory
upsAdvInputApparentPower
OBJECT-TYPE
The input apparent power(sum of all of the three phases) measured in kVA.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.2INTEGERread-onlymandatory
upsAdvInputVoltageTHD
OBJECT-TYPE
The input voltage Total Harmonic Distortion in percent.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.3INTEGERread-onlymandatory
upsAdvInputBypassVoltageTHD
OBJECT-TYPE
The bypass input voltage Total Harmonic Distortion in percent.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.4INTEGERread-onlymandatory
upsAdvInputPeakCurrent
OBJECT-TYPE
The input peak current in Amperes.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.5INTEGERread-onlymandatory
upsAdvInputBypassPeakCurrent
OBJECT-TYPE
The bypass input peak current in Amperes.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.6INTEGERread-onlymandatory
upsAdvInputActivePower
OBJECT-TYPE
The input active power measured in kW.
1.3.6.1.4.1.318.1.1.1.3.2.10.1.7INTEGERread-onlymandatory
upsAdvInputTotalApparentPower
OBJECT-TYPE
The input total apparent power(sum of all three phases) of the UPS system in kVA.
1.3.6.1.4.1.318.1.1.1.3.2.11INTEGERread-onlymandatory
upsAdvInputTotalActivePower
OBJECT-TYPE
The input total active power(sum of all three phases) of the UPS system in kW.
1.3.6.1.4.1.318.1.1.1.3.2.12INTEGERread-onlymandatory
upsAdvInputBypassTotalApparentPower
OBJECT-TYPE
The input bypass total apparent power(sum of all three phases) of the UPS system in kVA.
1.3.6.1.4.1.318.1.1.1.3.2.13INTEGERread-onlymandatory
upsAdvInputBypassTotalActivePower
OBJECT-TYPE
The input bypass total active power(sum of all three phases) of the UPS system in kW.
1.3.6.1.4.1.318.1.1.1.3.2.14INTEGERread-onlymandatory
upsAdvInputEnergyUsage
OBJECT-TYPE
The input energy usage of the UPS in kWh.
1.3.6.1.4.1.318.1.1.1.3.2.15Unsigned32read-onlymandatory
upsAdvInputDCVoltage
OBJECT-TYPE
The DC input voltage in Volts.
1.3.6.1.4.1.318.1.1.1.3.2.16INTEGERread-onlymandatory
upsAdvInputDCCurrent
OBJECT-TYPE
The DC input current in Amps.
1.3.6.1.4.1.318.1.1.1.3.2.17INTEGERread-onlymandatory
upsHighPrecInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.3.3
upsHighPrecInputLineVoltage
OBJECT-TYPE
The current utility line voltage in tenths of VAC.
1.3.6.1.4.1.318.1.1.1.3.3.1Gaugeread-onlymandatory
upsHighPrecInputMaxLineVoltage
OBJECT-TYPE
The maximum utility line voltage in tenths of VAC over the previous 1 minute period.
1.3.6.1.4.1.318.1.1.1.3.3.2Gaugeread-onlymandatory
upsHighPrecInputMinLineVoltage
OBJECT-TYPE
The minimum utility line voltage in tenths of VAC over the previous 1 minute period.
1.3.6.1.4.1.318.1.1.1.3.3.3Gaugeread-onlymandatory
upsHighPrecInputFrequency
OBJECT-TYPE
The current input frequency to the UPS system in tenths of Hz.
1.3.6.1.4.1.318.1.1.1.3.3.4Gaugeread-onlymandatory
upsHighPrecInputEnergyUsage
OBJECT-TYPE
The input energy usage of the UPS in hundredths of kWh.
1.3.6.1.4.1.318.1.1.1.3.3.5Unsigned32read-onlymandatory
upsHighPrecInputBypassVoltage
OBJECT-TYPE
The current bypass line voltage in tenths of VAC.
1.3.6.1.4.1.318.1.1.1.3.3.6Unsigned32read-onlymandatory
upsHighPrecInputBypassFrequency
OBJECT-TYPE
The current input bypass frequency to the UPS system in tenths of Hz.
1.3.6.1.4.1.318.1.1.1.3.3.7Unsigned32read-onlymandatory
upsOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.4
upsBasicOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.4.1
upsBasicOutputStatus
OBJECT-TYPE
The current state of the UPS. If the UPS is unable to determine the state of the UPS this variable is set to unknown(1). During self-test most UPSes report onBattery(3) but some that support it will report onBatteryTest(15). To determine self-test status across all UPSes, refer to the upsBasicStateOutputState OID.
1.3.6.1.4.1.318.1.1.1.4.1.1INTEGER {unknown(1), onLine(2), onBattery(3), onSmartBoost(4), timedSleeping(5), softwareBypass(6), off(7), rebooting(8), switchedBypass(9), hardwareFailureBypass(10), sleepingUntilPowerReturn(11), onSmartTrim(12), ecoMode(13), hotStandby(14), onBatteryTest(15), emergencyStaticBypass(16), staticBypassStandby(17), powerSavingMode(18), spotMode(19), eConversion(20), chargerSpotmode(21), inverterSpotmode(22), activeLoad(23), batteryDischargeSpotmode(24), inverterStandby(25), chargerOnly(26)}read-onlymandatory
upsBasicOutputPhase
OBJECT-TYPE
The actual number of output phases in a UPS
1.3.6.1.4.1.318.1.1.1.4.1.2INTEGERread-onlymandatory
upsBasicSystemStatus
OBJECT-TYPE
Current state for the whole system (UPS and surrounding breakers). If the UPS is unable to determine the state of the system, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.4.1.3INTEGER {unknown(1), onLine(2), onBattery(3), onSmartBoost(4), timedSleeping(5), softwareBypass(6), off(7), rebooting(8), switchedBypass(9), hardwareFailureBypass(10), sleepingUntilPowerReturn(11), onSmartTrim(12), ecoMode(13), inverter(14), eConversion(15), staticBypassStandby(16), efficiencyBoosterMode(17)}read-onlymandatory
upsBasicSystemInternalTemperature
OBJECT-TYPE
The actual internal temperature of the UPS system in Celsius.
1.3.6.1.4.1.318.1.1.1.4.1.4INTEGERread-onlymandatory
upsBasicSystemInverterStatus
OBJECT-TYPE
The current state of the UPS inverter. If the UPS is unable to determine the state of the inverter, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.4.1.5INTEGER {unknown(1), ok(2), inFaultCondition(3)}read-onlymandatory
upsBasicSystemPFCStatus
OBJECT-TYPE
The general status of the power factor correction (AC input stage of the UPS). If the UPS is unable to determine the state of PFC, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.4.1.6INTEGER {unknown(1), ok(2), inFaultCondition(3)}read-onlymandatory
upsBasicOutputACwiringConfiguration
OBJECT-TYPE
Indicates if neutral wire on output side of the UPS is used (load wired line to neutral). If the UPS is unable to determine the state of neutral, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.4.1.7INTEGER {unknown(1), noNeutralWiredonSystem(2), neutralUsedforSupplyingLoad(3)}read-onlymandatory
upsAdvOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.4.2
upsAdvOutputVoltage
OBJECT-TYPE
The output voltage of the UPS system in VAC.
1.3.6.1.4.1.318.1.1.1.4.2.1Gaugeread-onlymandatory
upsAdvOutputFrequency
OBJECT-TYPE
The current output frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.4.2.2Gaugeread-onlymandatory
upsAdvOutputLoad
OBJECT-TYPE
The current UPS load expressed in percent of rated capacity.
1.3.6.1.4.1.318.1.1.1.4.2.3Gaugeread-onlymandatory
upsAdvOutputCurrent
OBJECT-TYPE
The current in amperes drawn by the load on the UPS.
1.3.6.1.4.1.318.1.1.1.4.2.4Gaugeread-onlymandatory
upsAdvOutputRedundancy
OBJECT-TYPE
The number of power modules which can fail or be removed without causing the UPS to generate a Minimum Redundancy Lost event.
1.3.6.1.4.1.318.1.1.1.4.2.5Gaugeread-onlymandatory
upsAdvOutputKVACapacity
OBJECT-TYPE
The maximum load that this UPS can support. This value is dynamic for scalable 3-phase UPSs where power modules can be added for increased capacity. The value indicates the actual available output capacity. For non-scalable 3-phase UPSs the value is fixed to the UPS rating.
1.3.6.1.4.1.318.1.1.1.4.2.6INTEGERread-onlymandatory
upsAdvOutputNominalFrequency
OBJECT-TYPE
The nominal output frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.4.2.7INTEGERread-onlymandatory
upsAdvOutputActivePower
OBJECT-TYPE
The total output active power of the UPS system in W. The total active power is the sum of phase 1, phase 2 and phase 3 power.
1.3.6.1.4.1.318.1.1.1.4.2.8INTEGERread-onlymandatory
upsAdvOutputApparentPower
OBJECT-TYPE
The total output apparent power of all phases of the UPS system in VA.
1.3.6.1.4.1.318.1.1.1.4.2.9INTEGERread-onlymandatory
upsAdvOutputStatisticsTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the value of upsPhaseNumOutputs.
1.3.6.1.4.1.318.1.1.1.4.2.10not-accessiblemandatory
upsAdvOutputStatisticsEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.1.4.2.10.1not-accessiblemandatory
upsAdvOutputStatisticsIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.1.4.2.10.1.1INTEGERread-onlymandatory
upsAdvOutputPeakCurrent
OBJECT-TYPE
The output peak current in Amperes.
1.3.6.1.4.1.318.1.1.1.4.2.10.1.2INTEGERread-onlymandatory
upsAdvOutputCurrentTHD
OBJECT-TYPE
The output current Total Harmonic Distortion in percent.
1.3.6.1.4.1.318.1.1.1.4.2.10.1.3INTEGERread-onlymandatory
upsAdvOutputCrestFactor
OBJECT-TYPE
The output current crest factor expressed in tenths.
1.3.6.1.4.1.318.1.1.1.4.2.10.1.4INTEGERread-onlymandatory
upsAdvOutputNeutralCurrent
OBJECT-TYPE
The neutral current in amperes.
1.3.6.1.4.1.318.1.1.1.4.2.11INTEGERread-onlymandatory
upsAdvOutputEnergyUsage
OBJECT-TYPE
The output energy usage of the UPS in kWh.
1.3.6.1.4.1.318.1.1.1.4.2.12Unsigned32read-onlymandatory
upsAdvOutputSourceSynchronization
OBJECT-TYPE
Indicates the synchronization source for the inverter output frequency. 1. Main 2. Internal 3. External 4. On AC Bypass. 5. External / On Bypass For other values it is unknown
1.3.6.1.4.1.318.1.1.1.4.2.13INTEGERread-onlymandatory
upsAdvOutputInverterFrequency
OBJECT-TYPE
Output frequency in Hz measured at the output of inverter.
1.3.6.1.4.1.318.1.1.1.4.2.14Gaugeread-onlymandatory
upsHighPrecOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.4.3
upsHighPrecOutputVoltage
OBJECT-TYPE
The output voltage of the UPS system in tenths of VAC.
1.3.6.1.4.1.318.1.1.1.4.3.1Gaugeread-onlymandatory
upsHighPrecOutputFrequency
OBJECT-TYPE
The current output frequency of the UPS system in tenths of Hz.
1.3.6.1.4.1.318.1.1.1.4.3.2Gaugeread-onlymandatory
upsHighPrecOutputLoad
OBJECT-TYPE
The current UPS load expressed in tenths of percent of rated capacity.
1.3.6.1.4.1.318.1.1.1.4.3.3Gaugeread-onlymandatory
upsHighPrecOutputCurrent
OBJECT-TYPE
The current in tenths of amperes drawn by the load on the UPS.
1.3.6.1.4.1.318.1.1.1.4.3.4Gaugeread-onlymandatory
upsHighPrecOutputEfficiency
OBJECT-TYPE
The positive values represent efficiency of the UPS in tenths of percent. -1 If UPS supports this OID but the result is not available -2 Load is too low to report efficiency -3 Output off and efficiency is 0 -4 On battery, efficiency is not measured or calculated in this mode -5 In Bypass, efficiency is not measured or calculated in this mode -6 Battery charging, battery is charging and adversely affecting efficiency -7 Poor AC input, the main input is outside the optimum efficiency range
1.3.6.1.4.1.318.1.1.1.4.3.5Integer32read-onlymandatory
upsHighPrecOutputEnergyUsage
OBJECT-TYPE
The output energy usage of the UPS in hundredths of kWh.
1.3.6.1.4.1.318.1.1.1.4.3.6Unsigned32read-onlymandatory
upsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.5
upsBasicConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.5.1
upsBasicConfigNumDevices
OBJECT-TYPE
The number of devices that are plugged into the UPS. This value is customer configurable from the device entry table
1.3.6.1.4.1.318.1.1.1.5.1.1INTEGERread-onlymandatory
upsBasicConfigDeviceTable
OBJECT-TYPE
A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBasicConfigNumDevices.
1.3.6.1.4.1.318.1.1.1.5.1.2not-accessiblemandatory
upsBasicConfigDeviceEntry
OBJECT-TYPE
The devices plugged in to the UPS.
1.3.6.1.4.1.318.1.1.1.5.1.2.1not-accessiblemandatory
deviceIndex
OBJECT-TYPE
The index of the device that is plugged into the UPS.
1.3.6.1.4.1.318.1.1.1.5.1.2.1.1INTEGERread-onlymandatory
deviceName
OBJECT-TYPE
The name/description of the device plugged into the UPS.
1.3.6.1.4.1.318.1.1.1.5.1.2.1.2DisplayStringread-writemandatory
vaRating
OBJECT-TYPE
The volt-amp rating of the device plugged into the UPS.
1.3.6.1.4.1.318.1.1.1.5.1.2.1.3INTEGERread-writemandatory
acceptThisDevice
OBJECT-TYPE
An entry is added if yes, the entry is deleted if no.
1.3.6.1.4.1.318.1.1.1.5.1.2.1.4INTEGER {yes(1), no(2)}read-writemandatory
upsAdvConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.5.2
upsAdvConfigRatedOutputVoltage
OBJECT-TYPE
The nominal output voltage from the UPS in VAC. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.1INTEGERread-writemandatory
upsAdvConfigHighTransferVolt
OBJECT-TYPE
The maximum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.2INTEGERread-writemandatory
upsAdvConfigLowTransferVolt
OBJECT-TYPE
The minimum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.3INTEGERread-writemandatory
upsAdvConfigAlarm
OBJECT-TYPE
A flag indicating how the UPS should handle audible line fail alarms: timed(1): UPS alarm will sound after a preset timed duration starting from the line fail condition (see OID upsAdvConfigAlarmTimer for the alarm timer value) atLowBattery(2): UPS alarm will sound when the UPS has reached a Low Battery condition during a line fail never(3): Disables the UPS audible alarm mute(4): Mutes the current alarm for some UPSs only when it is in an alarm state and will return to the previously configured option when the UPS recovers from the alarm condition
1.3.6.1.4.1.318.1.1.1.5.2.4INTEGER {timed(1), atLowBattery(2), never(3), mute(4)}read-writemandatory
upsAdvConfigAlarmTimer
OBJECT-TYPE
The time after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observed only if the value of extControlAlarm is timed(2). Allowed values are 0 or 30 seconds. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.5TimeTicksread-writemandatory
upsAdvConfigMinReturnCapacity
OBJECT-TYPE
The minimum battery capacity required before the UPS will return from a low battery shutdown condition. The capacity is measured from 0% battery capacity (or Low Battery) as a percent of full capacity (100%). In other words, the UPS will not re-energize the output until the battery has charged so that its' capacity is equal to this value. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.6INTEGERread-writemandatory
upsAdvConfigSensitivity
OBJECT-TYPE
The sensitivity of the UPS to utility line abnormalities or noises.
1.3.6.1.4.1.318.1.1.1.5.2.7INTEGER {auto(1), low(2), medium(3), high(4)}read-writemandatory
upsAdvConfigLowBatteryRunTime
OBJECT-TYPE
The desired run time of the UPS, in seconds, once the low battery condition is reached. During this time the UPS will produce a constant warning tone which can not be disabled. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets the value as the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.8TimeTicksread-writemandatory
upsAdvConfigReturnDelay
OBJECT-TYPE
The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes out of a reboot and before the UPS wakes up from 'sleep' mode. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.9TimeTicksread-writemandatory
upsAdvConfigShutoffDelay
OBJECT-TYPE
The delay in seconds the UPS remains on after being told to turn off. For a list of allowed values supported by your UPS model, see the UPS User's Manual. If a value other than a supported value is provided in a set request, the UPS interprets it as a the next higher acceptable value. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.
1.3.6.1.4.1.318.1.1.1.5.2.10TimeTicksread-writemandatory
upsAdvConfigUpsSleepTime
OBJECT-TYPE
The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 1/10 of an hour increments. The provided value will be rounded to the closest 1/10 of an hour with one exception: Any value entered between 1 and 540 seconds will be rounded to 360 seconds (or 6 minutes).
1.3.6.1.4.1.318.1.1.1.5.2.11TimeTicksread-writemandatory
upsAdvConfigSetEEPROMDefaults
OBJECT-TYPE
WRITE: Resets the UPS EEPROM variables to default values. READ: returns 1
1.3.6.1.4.1.318.1.1.1.5.2.12INTEGER {noSetEEPROMDefaults(1), setEEPROMDefaults(2)}read-writemandatory
upsAdvConfigDipSwitchTable
OBJECT-TYPE
Current settings of UPS dip switches.
1.3.6.1.4.1.318.1.1.1.5.2.13not-accessiblemandatory
upsAdvConfigDipSwitchEntry
OBJECT-TYPE
The current setting of one dip switch.
1.3.6.1.4.1.318.1.1.1.5.2.13.1not-accessiblemandatory
dipSwitchIndex
OBJECT-TYPE
The index of a UPS dip switch.
1.3.6.1.4.1.318.1.1.1.5.2.13.1.1INTEGERread-onlymandatory
dipSwitchStatus
OBJECT-TYPE
The setting of a UPS dip switch.
1.3.6.1.4.1.318.1.1.1.5.2.13.1.2INTEGER {on(1), off(2)}read-onlymandatory
upsAdvConfigBattExhaustThresh
OBJECT-TYPE
The number of seconds prior to battery exhaustion when the UPS will switch off power to its load.
1.3.6.1.4.1.318.1.1.1.5.2.14TimeTicksread-writemandatory
upsAdvConfigPassword
OBJECT-TYPE
The password entered at the UPS front panel to enable local configuration of the EEProm. If the password is disabled or is not supported, then the agent returns a null string.
1.3.6.1.4.1.318.1.1.1.5.2.15DisplayStringread-writemandatory
upsAdvConfigAllowedSetTable
OBJECT-TYPE
The table listing the allowed values for all discrete configurable UPS variables.
1.3.6.1.4.1.318.1.1.1.5.2.16not-accessiblemandatory
upsAdvConfigAllowedSetEntry
OBJECT-TYPE
The table entry for a configurable UPS variable.
1.3.6.1.4.1.318.1.1.1.5.2.16.1not-accessiblemandatory
apcUpsConfigFieldIndex
OBJECT-TYPE
The index to an eeprom field entry.
1.3.6.1.4.1.318.1.1.1.5.2.16.1.1INTEGERread-onlymandatory
apcUpsConfigFieldOID
OBJECT-TYPE
The OID of the current configurable value.
1.3.6.1.4.1.318.1.1.1.5.2.16.1.2OBJECT IDENTIFIERread-onlymandatory
apcUpsConfigFieldValueRange
OBJECT-TYPE
The discrete set of allowed values of a configurable register. Individual values are delimited by a comma.
1.3.6.1.4.1.318.1.1.1.5.2.16.1.3DisplayStringread-onlymandatory
upsAdvConfigBattCabAmpHour
OBJECT-TYPE
Configure the amp-hour setting of the UPS battery solution. The value shows the maximum battery capacity configured for the UPS when using a third party battery solution regardless of the breaker positions. The actual available battery capacity based on breaker positions or connected/disconnected battery strings, is presented in OID upsAdvBatteryTotalCapacity
1.3.6.1.4.1.318.1.1.1.5.2.17INTEGERread-writemandatory
upsAdvConfigPositionSelector
OBJECT-TYPE
Configure UPS position selector. If the UPS doesn't support this configuration it will report unknown (1). The positions are either rack (2) for rack mounted or tower (3) for tower unit.
1.3.6.1.4.1.318.1.1.1.5.2.18INTEGER {unknown(1), rack(2), tower(3)}read-writemandatory
upsAdvConfigOutputFreqRange
OBJECT-TYPE
Configure the output frequency tolerance range. unknown(1) indicates the output frequency is unknown. freqRangeAUTO(2) configure the output frequency range for automatic. freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 % freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 % freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 % freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 % freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 % freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 % freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 % freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 % freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 % freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 % freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 % freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 % For a list of allowed values and conditions when variable can be set by your UPS model, see the UPS User's Manual.
1.3.6.1.4.1.318.1.1.1.5.2.19INTEGER {unknown(1), freqRangeAUTO(2), freqRange60Var1(3), freqRange60Var3(4), freqRange50Var1(5), freqRange50Var3(6), freqRange60Var10(7), freqRange50Var10(8), freqRange60Var1dot0(9), freqRange50Var1dot0(10), freqRange50Pct0dot5(11), freqRange50Pct1(12), freqRange50Pct2(13), freqRange50Pct4(14), freqRange50Pct6(15), freqRange50Pct8(16), freqRange60Pct0dot5(17), freqRange60Pct1(18), freqRange60Pct2(19), freqRange60Pct4(20), freqRange60Pct6(21), freqRange60Pct8(22)}read-writemandatory
upsAdvConfigUPSFail
OBJECT-TYPE
Configure the UPS fail action. If UPS fails, and frequency or voltage is out of range it will either GotoBypass (2) or DropLoad (3). This OID will report unknown (1) if it is not supported feature or option.
1.3.6.1.4.1.318.1.1.1.5.2.20INTEGER {unknown(1), gotoBypass(2), dropLoad(3)}read-writemandatory
upsAdvConfigAlarmRedundancy
OBJECT-TYPE
Configure settings of UPS alarm if the redundancy is under the current redundancy. Use 0 for never.
1.3.6.1.4.1.318.1.1.1.5.2.21INTEGERread-writemandatory
upsAdvConfigAlarmLoadOver
OBJECT-TYPE
Configure settings of UPS alarm if the load is over the current load in kVA. Use -1 for never.
1.3.6.1.4.1.318.1.1.1.5.2.22INTEGERread-writemandatory
upsAdvConfigAlarmRuntimeUnder
OBJECT-TYPE
Configure settings of UPS alarm if the runtime is under the current time of minutes. Use -1 for never.
1.3.6.1.4.1.318.1.1.1.5.2.23INTEGERread-writemandatory
upsAdvConfigVoutReporting
OBJECT-TYPE
Configure the way the UPS scales its output voltage readings. unknown(1) indicates the Vout Reporting is unknown. voutAUTO(2) configure the Vout Reporting for automatic scaling. vout208(3) configure the Vout Reporting for 208 Volts. vout240(4) configure the Vout Reporting for 240 Volts.
1.3.6.1.4.1.318.1.1.1.5.2.24INTEGER {unknown(1), voutAUTO(2), vout208(3), vout240(4)}read-writemandatory
upsAdvConfigNumExternalBatteries
OBJECT-TYPE
Configure the number of external batteries connected to the UPS.
1.3.6.1.4.1.318.1.1.1.5.2.25INTEGERread-writemandatory
upsAdvConfigSimpleSignalShutdowns
OBJECT-TYPE
Configure Simple Signal shutdown commands from the Simple Signal port to be issued to the UPS. unknown(1) indicates the Simple Signal Shutdown setting is unknown. disabled(2) configure to disable Simple Signal Shutdowns. enabled(3) configure to enable Simple Signal Shutdowns.
1.3.6.1.4.1.318.1.1.1.5.2.26INTEGER {unknown(1), disabled(2), enabled(3)}read-writemandatory
upsAdvConfigMaxShutdownTime
OBJECT-TYPE
The maximum amount of time for server shutdown to complete before a UPS shutdown occurs.
1.3.6.1.4.1.318.1.1.1.5.2.27INTEGERread-writemandatory
upsAsiUpsControlServerRequestShutdown
OBJECT-TYPE
Start a server shutdown sequence: serverShutdownOff: Shutdown server and turn off UPS serverShutdownReboot: Shutdown server and turn reboot UPS.
1.3.6.1.4.1.318.1.1.1.5.2.28INTEGER {serverShutdownOff(1), serverShutdownReboot(2)}read-writemandatory
upsAdvConfigMinReturnRuntime
OBJECT-TYPE
The minimum amount of run time in seconds required before the output will be turned on, using power calculation captured at start of last shutdown.
1.3.6.1.4.1.318.1.1.1.5.2.29TimeTicksread-writemandatory
upsAdvConfigBasicSignalLowBatteryDuration
OBJECT-TYPE
The duration of runtime in seconds during an on-battery condition at which the UPS will signal the basic low battery shutdown condition.
1.3.6.1.4.1.318.1.1.1.5.2.30TimeTicksread-writemandatory
upsAdvConfigBypassPhaseLockRequired
OBJECT-TYPE
Sets the condition for when bypass is an acceptable mode of operation as a requirement.
1.3.6.1.4.1.318.1.1.1.5.2.31INTEGER {unknown(1), disabled(2), enabled(3)}read-writemandatory
upsAdvConfigOutputFreqSlewRate
OBJECT-TYPE
The rate at which the UPS will change its output frequency in response to utility frequency changes.
1.3.6.1.4.1.318.1.1.1.5.2.32INTEGER {unknown(1), slewRateQuarterHzPerSec(2), slewRateHalfHzPerSec(3), slewRate1HzPerSec(4), slewRate2HzPerSec(5), slewRate4HzPerSec(6), slewRate6HzPerSec(7)}read-writemandatory
upsAdvConfigChargerLevel
OBJECT-TYPE
Sets the rate at which the UPS charges its batteries.
1.3.6.1.4.1.318.1.1.1.5.2.33INTEGER {unknown(1), low(2), high(3)}read-writemandatory
upsAdvConfigBypassToleranceSetting
OBJECT-TYPE
This setting allows selecting from standard bypass tolerance configurations to suit their situation.
1.3.6.1.4.1.318.1.1.1.5.2.34INTEGER {unknown(1), wide(2), medium(3), narrow(4), custom(5)}read-writemandatory
upsAdvConfigMainsSetting
OBJECT-TYPE
Configure the type of mains supply system. singleInput (1) indicates a single supply system. dualInput (2) indicates a dual supply system.
1.3.6.1.4.1.318.1.1.1.5.2.35INTEGER {singleInput(1), dualInput(2)}read-onlymandatory
upsAdvConfigACWiringSetting
OBJECT-TYPE
Configure the AC wiring of the system. threeWire (1) indicates 3-wire system configuration. fourWire (2) indicates 4-wire system configuration. fourWireHRG (3) indicates a 4-wire High resistive Grounding system.
1.3.6.1.4.1.318.1.1.1.5.2.36INTEGER {threeWire(1), fourWire(2), fourWireHRG(3)}read-onlymandatory
upsAdvConfigUpperOutputVoltTolerance
OBJECT-TYPE
Upper tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage.
1.3.6.1.4.1.318.1.1.1.5.2.37INTEGER (0..100)read-writemandatory
upsAdvConfigLowerOutputVoltTolerance
OBJECT-TYPE
Lower tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage.
1.3.6.1.4.1.318.1.1.1.5.2.38INTEGER (0..100)read-writemandatory
upsAdvConfigUpperBypassVoltTolerance
OBJECT-TYPE
Upper tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage.
1.3.6.1.4.1.318.1.1.1.5.2.39INTEGER (0..100)read-writemandatory
upsAdvConfigLowerBypassVoltTolerance
OBJECT-TYPE
Lower tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage.
1.3.6.1.4.1.318.1.1.1.5.2.40INTEGER (0..100)read-writemandatory
upsAdvConfigOutofSyncBypassTransferDelay
OBJECT-TYPE
Configure the time (in milliseconds), indicating the gap in output voltage if an asynchronous transfer to bypass needs to occur.
1.3.6.1.4.1.318.1.1.1.5.2.41INTEGERread-writemandatory
upsAdvConfigWarningAlarmDelay
OBJECT-TYPE
Configure the time delay for reporting warning alarms (in seconds).
1.3.6.1.4.1.318.1.1.1.5.2.43INTEGERread-writemandatory
upsAdvConfigInformationalAlarmDelay
OBJECT-TYPE
Configure the time delay for reporting informational alarms (in seconds).
1.3.6.1.4.1.318.1.1.1.5.2.44INTEGERread-writemandatory
upsAdvConfigGreenMode
OBJECT-TYPE
Enable/Disable UPS green mode feature.
1.3.6.1.4.1.318.1.1.1.5.2.45INTEGER {disable(1), enable(2)}read-writemandatory
upsAdvConfigLCDLocalLanguage
OBJECT-TYPE
Configure the language setting of the UPS LCD display information.
1.3.6.1.4.1.318.1.1.1.5.2.46INTEGER {english(1), french(2), italian(3), german(4), spanish(5), portuguese(6), japanese(7)}read-writemandatory
upsAdvConfigLCDLockOut
OBJECT-TYPE
Enable/Disable the control function of the UPS via the LCD Display.
1.3.6.1.4.1.318.1.1.1.5.2.47INTEGER {disable(1), enable(2)}read-writemandatory
upsAdvConfigChargerRate
OBJECT-TYPE
Change the maximum allowed UPS charge rate on select products where 100% represents the manufacturer's recommended rate. A charge/discharge rate of C/10 for a 10 Ah battery would be 1 where C is defined as the charge or discharge rate equal to the capacity of a battery divided by 1 hour. To increase the charge rate by a factor of 2 to C/5, this oid would be set to 200%. This number would not change when external packs are added or removed. Charging at too high a rate can result in boiling and/or venting of electrolyte and/or high gas pressure.
1.3.6.1.4.1.318.1.1.1.5.2.48INTEGERread-writemandatory
upsAdvConfigBatterySelection
OBJECT-TYPE
Configure the installed battery type; VRLA is a Valve Regulated Lead Acid type battery, Vented Cell is a wet cell type (car) battery, NiCd is a Nickel-Cadmium type battery, and Li-Ion is Lithium Ion type battery. Please use the OID defined under upsIdent: upsAdvEnergyStorageType
1.3.6.1.4.1.318.1.1.1.5.2.49INTEGER {vrla(1), ventedcell(2), nicd(3), li-ion(4)}read-writemandatory
upsAdvConfigBatteryHealthAlarmWarningTime
OBJECT-TYPE
Configure the number of days before the battery health is depleted that the battery health alarm is activated. Setting this to -1, if supported by the UPS, will suppress the battery health alarm.
1.3.6.1.4.1.318.1.1.1.5.2.50INTEGERread-writemandatory
upsAdvConfigBatteryHealthAlarmSleepTime
OBJECT-TYPE
Configure the number of days that the UPS's battery health alarm should sleep before being activated again after being acknowledged. Setting this to -1, if supported by the UPS, displays no other alarms after the first alarm is acknowledged.
1.3.6.1.4.1.318.1.1.1.5.2.51INTEGERread-writemandatory
upsAdvConfigSignalFlashVoltage
OBJECT-TYPE
Configure the signal flash voltage in tenths of volts.
1.3.6.1.4.1.318.1.1.1.5.2.52INTEGERread-writemandatory
upsAdvConfigBatteryTemperatureCompensation
OBJECT-TYPE
Configure the battery temperature compensation voltage in hundreds of volts per degree C. On products which support this field, the charger voltage is reduced for each degree C rise by the value configured in this setting multiplied by the number of battery cells attached to the UPS.
1.3.6.1.4.1.318.1.1.1.5.2.53INTEGERread-writemandatory
upsAdvConfigBatteryChargerType
OBJECT-TYPE
This OID describes type of battery charger used: standard or extended. 1 - Internal charger, 2 - Extended (CLA), 3 - Large extension (other cases), 4 - Extra large extension (XL), 5 - Double extra large extension (XXL) For other numbers charger type is unknown
1.3.6.1.4.1.318.1.1.1.5.2.54INTEGERread-writemandatory
upsAdvConfigAutomaticRestart
OBJECT-TYPE
Indicates whether Automatic Restart is enabled or disabled.
1.3.6.1.4.1.318.1.1.1.5.2.55INTEGER {enabled(1), disabled(2)}read-writemandatory
upsAdvConfigDeepDischargeProtection
OBJECT-TYPE
Indicates whether protection against deep discharge is enabled or disabled.
1.3.6.1.4.1.318.1.1.1.5.2.56INTEGER {enabled(1), disabled(2)}read-writemandatory
upsAdvConfigFreqBypassTransferRange
OBJECT-TYPE
Tolerance of bypass AC frequency to switch on bypass. The frequency must be in range of -X% to +X% around the nominal value.
1.3.6.1.4.1.318.1.1.1.5.2.57INTEGERread-writemandatory
upsAdvConfigUpsPowerconverterType
OBJECT-TYPE
This value indicates the type of UPS in terms of output phase and redundancy. 2 - Galaxy 7000 Unitary 3:3 3 - Galaxy 7000 Redundant 3:3 4 - Galaxy 7000 Parallel SSC 3:3 6 - Galaxy 7000 SSC 3:3 10 - Galaxy 300 Unitary 3:3 11 - Galaxy 300 Unitary 3:1 12 - Galaxy 300 Redundant 3:3 13 - Galaxy 300 Redundant 3:1 14 - Galaxy 5000/5500 Unitary 15 - Galaxy 5000/5500 Parallel 16 - Galaxy 5000/5500 Unitary Frequency Converter 17 - Galaxy 5000/5500 Parallel Frequency Converter For other values UPS is unknown.
1.3.6.1.4.1.318.1.1.1.5.2.58INTEGERread-writemandatory
upsAdvConfigFrequencyConverterMode
OBJECT-TYPE
Indicates whether the output frequency is in Auto Ranging or Frequency converter mode. In Auto Ranging mode the inverter provides output frequency in the same range as the input. In Frequency converter mode it is possible to have 50Hz input and 60 Hz output and vice versa.
1.3.6.1.4.1.318.1.1.1.5.2.59INTEGER {autoRanging(1), frequencyConverter(2), unknown(3)}read-writemandatory
upsAdvConfigACQualificationTime
OBJECT-TYPE
The time in seconds that the voltage is required to be in the acceptable range before being declared to be acceptable.
1.3.6.1.4.1.318.1.1.1.5.2.60INTEGERread-writemandatory
upsControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.6
upsBasicControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.6.1
upsBasicControlConserveBattery
OBJECT-TYPE
Setting this variable to turnUpsOffToConserveBattery(2) causes a UPS on battery to be put into 'sleep' mode. The UPS will turn back on when utility power is restored. Attempting to turn off a UPS that is not on battery will result in a badValue error. Setting this value to noTurnOffUps(1) has no effect. The value noTurnOffUps(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.1.1INTEGER {noTurnOffUps(1), turnOffUpsToConserveBattery(2)}read-writemandatory
upsAdvControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.6.2
upsAdvControlUpsOff
OBJECT-TYPE
Setting this variable to turnUpsOff(2) causes the UPS to shut off. When in this state, the UPS will not provide output power regardless of the input line state. Setting this variable to turnUpsOffGracefully(3) causes the UPS to shut off after a delay period. This allows the host to shut down in a graceful manner. When in this state, the UPS will not provide output power regardless of the input line state. If this UPS is an active member of a Synchronized Control Group (SCG) the turnUpsSyncGroupOff(4) command will perform a Synchronized Turn Off of all active Group members regardless of their current AC output status. If this UPS is an active member of a Synchronized Control Group (SCG) the turnUpsSyncGroupOffAfterDelay(5) command will perform a Synchronized Turn Off After Delay of all active Group members regardless of their current AC output status. This unit's Shutdown Delay will be used to execute the Turn Off After Delay command. If this UPS is an active member of an SCG, the turnUpsSyncGroupOffGracefully(6) command will perform a Synchronized Turn Off Gracefully of all active Group members regardless of their current AC output status. This unit's Maximum Shutdown Time and Shutdown Delay will be used to execute the Turn Off Gracefully command. Setting this value to noTurnUpsOff(1) has no effect. The value noTurnUpsOff(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.1INTEGER {noTurnUpsOff(1), turnUpsOff(2), turnUpsOffGracefully(3), turnUpsSyncGroupOff(4), turnUpsSyncGroupOffAfterDelay(5), turnUpsSyncGroupOffGracefully(6)}read-writemandatory
upsAdvControlRebootShutdownUps
OBJECT-TYPE
Setting this variable to rebootShutdownUps(2) causes the UPS to shut off and turn back on (as long as good AC input power is available, otherwise the UPS will remain off until good AC input power is available). Setting this variable to rebootShutdownUpsGracefully(3) causes the UPS to shut off after a delay period and then turn back on. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG) the rebootShutdownSyncGroupUps(4) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. If this UPS is an active member of a SCG the rebootShutdownSyncGroupUpsGracefully(5) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. Setting this value to noRebootShutdownUps(1) has no effect. The value noRebootShutdownUps(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.2INTEGER {noRebootShutdownUps(1), rebootShutdownUps(2), rebootShutdownUpsGracefully(3), rebootShutdownSyncGroupUps(4), rebootShutdownSyncGroupUpsGracefully(5)}read-writemandatory
upsAdvControlUpsSleep
OBJECT-TYPE
Setting this variable to putUpsToSleep(2) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime. Setting this variable to putUpsToSleepGracefully(3) causes the UPS to go to sleep for the time specified by upsAdvConfigUpsSleepTime after a delay period. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG), the putUpsSyncGroupToSleep(4) command will perform a Synchronized Sleep of all active Group members regardless of their current AC output status. This unit's Power Synchronization Delay, Shutdown Delay, Sleep Time, and Return Delay will be used to execute the sleep command. If this UPS is an active member of a SCG the putUpsSyncGroupToSleepGracefully(5) command will perform a Synchronized Sleep Gracefully of all active Group members regardless of their current AC output status. This unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Sleep Time, and Return Delay to execute the sleep command. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. Setting this value to noPutUpsToSleep(1) has no effect. The value noPutUpsToSleep(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.3INTEGER {noPutUpsToSleep(1), putUpsToSleep(2), putUpsToSleepGracefully(3), putUpsSyncGroupToSleep(4), putUpsSyncGroupToSleepGracefully(5)}read-writemandatory
upsAdvControlSimulatePowerFail
OBJECT-TYPE
Setting this variable to simulatePowerFailure(2) causes the UPS switch to battery power. Setting this value to noSimulatePowerFailure(1) has no effect. The value noSimulatePowerFailure(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.4INTEGER {noSimulatePowerFailure(1), simulatePowerFailure(2)}read-writemandatory
upsAdvControlFlashAndBeep
OBJECT-TYPE
Setting this variable to flashAndBeep(2) causes the UPS to beep and simultaneously turn on the UPS front panel lights (Smart-UPS only). If this UPS is an active member of a Synchronized Control Group (SCG), the flashAndBeepSyncGroup(3) command will Flash and Beep all active Group members regardless of current AC output status. Setting this value to noFlashAndBeep(1) has no effect. Setting this value to flashAndBeepCont (4) commandcauses the UPS to beep and light the front panel lights until the flashAndBeepCancel (5) command is received. The value noFlashAndBeep(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.5INTEGER {noFlashAndBeep(1), flashAndBeep(2), flashAndBeepSyncGroup(3), flashAndBeepCont(4), flashAndBeepCancel(5)}read-writemandatory
upsAdvControlTurnOnUPS
OBJECT-TYPE
Setting this variable to turnOnUPS(2) causes the UPS to be turned on immediately. If this UPS is an active member of a Synchronized Control Group (SCG), the turnOnUPSSyncGroup(3) command will perform a Synchronized Turn On of all active Group members regardless of their current AC output status. Setting this value to noTurnOnUPS(1) has no effect. The value noTurnOnUPS(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.6INTEGER {noTurnOnUPS(1), turnOnUPS(2), turnOnUPSSyncGroup(3)}read-writemandatory
upsAdvControlBypassSwitch
OBJECT-TYPE
This switch puts the UPS in or out of bypass mode.
1.3.6.1.4.1.318.1.1.1.6.2.7INTEGER {noBypassSwitch(1), switchToBypass(2), switchOutOfBypass(3)}read-writemandatory
upsAdvControlRebootUpsWithOrWithoutAC
OBJECT-TYPE
Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2) causes the UPS to turn off immediately, wait for a minimum time (typically 8 seconds), and then turn back on regardless of the AC input power on the UPS. Any supported switched outlet groups will be turned off immediately but will turn on based on their individual settings (to allow on sequencing). Setting this variable to rebootUpsDelayedWithOrWithoutAC (3) causes the UPS to turn off after a delay period, wait for a minimum time (typically 8 seconds), and then turn back on regardless of the AC input power on the UPS. Any supported switched outlet groups will be turned off and on based on their individual settings (to allow off and/or on sequencing). Setting this value to noRebootUpsWithOrWithoutAC (1) has no effect. The value noRebootUpsWithOrWithoutAC (1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.6.2.8INTEGER {noRebootUpsWithOrWithoutAC(1), rebootUpsImmediatelyWithOrWithoutAC(2), rebootUpsDelayedWithOrWithoutAC(3)}read-writemandatory
upsAdvControlFirmwareUpdate
OBJECT-TYPE
Setting this variable to firmwareUpdate(2) causes the UPS to begin a firmware update if possible. Setting this value to noFirmwareUpdate(1) will clear the previous results, if any, or otherwise has no effect. Reading this variable will return noFirmwareUpdate(1) when the UPS firmware has not been updated (or previous results have been cleared), updateInProcess(3) when the UPS firmware is being updated, updateSuccessful(4) when the UPS firmware has been successfully updated, or updateFailed(5) if the UPS firmware update failed.
1.3.6.1.4.1.318.1.1.1.6.2.9INTEGER {noFirmwareUpdate(1), firmwareUpdate(2), updateInProcess(3), updateSuccessful(4), updateFailed(5)}read-writemandatory
upsTest
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.7
upsBasicTest
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.7.1
upsAdvTest
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.7.2
upsAdvTestDiagnosticSchedule
OBJECT-TYPE
The UPS system's automatic battery test schedule.
1.3.6.1.4.1.318.1.1.1.7.2.1INTEGER {unknown(1), biweekly(2), weekly(3), atTurnOn(4), never(5), fourWeeks(6), twelveWeeks(7), biweeklySinceLastTest(8), weeklySinceLastTest(9), eightWeeks(10), twentysixWeeks(11), fiftytwoWeeks(12)}read-writemandatory
upsAdvTestDiagnostics
OBJECT-TYPE
Setting this variable to testDiagnostics(2) causes the UPS to perform a diagnostic self test. Setting this value to noTestDiagnostics(1) has no effect. The value noTestDiagnostics(1) will always be returned when the variable is read.
1.3.6.1.4.1.318.1.1.1.7.2.2INTEGER {noTestDiagnostics(1), testDiagnostics(2)}read-writemandatory
upsAdvTestDiagnosticsResults
OBJECT-TYPE
The results of the last UPS diagnostics test performed.
1.3.6.1.4.1.318.1.1.1.7.2.3INTEGER {ok(1), failed(2), invalidTest(3), testInProgress(4)}read-onlymandatory
upsAdvTestLastDiagnosticsDate
OBJECT-TYPE
The date the last UPS diagnostics test was performed in mm/dd/yy format.
1.3.6.1.4.1.318.1.1.1.7.2.4DisplayStringread-onlymandatory
upsAdvTestRuntimeCalibration
OBJECT-TYPE
Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsAdvTestCalibrationResult.
1.3.6.1.4.1.318.1.1.1.7.2.5INTEGER {noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3)}read-writemandatory
upsAdvTestCalibrationResults
OBJECT-TYPE
The results of the last runtime calibration. Value ok(1) means a successful runtime calibration. Value invalidCalibration(2) indicates last calibration did not take place since the battery capacity was below 100%. Value calibrationInProgress(3) means a calibration is occurring now. Value refused(4) means the test was refused, it did not take place. Value aborted(5) indicates the test started but either someone cancelled it or the system encountered an error. Value pending(6) the test will commence shortly.
1.3.6.1.4.1.318.1.1.1.7.2.6INTEGER {ok(1), invalidCalibration(2), calibrationInProgress(3), refused(4), aborted(5), pending(6), unknown(7)}read-onlymandatory
upsAdvTestCalibrationDate
OBJECT-TYPE
The date the last UPS runtime calibration was performed in mm/dd/yy format.
1.3.6.1.4.1.318.1.1.1.7.2.7DisplayStringread-onlymandatory
upsAdvTestDiagnosticTime
OBJECT-TYPE
The time of the day to perform automatic battery test. Expressed in 24 hour notation - hh:mm.
1.3.6.1.4.1.318.1.1.1.7.2.8DisplayStringread-writemandatory
upsAdvTestDiagnosticDay
OBJECT-TYPE
The day of the week to perform automatic battery test.
1.3.6.1.4.1.318.1.1.1.7.2.9INTEGER {monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7)}read-writemandatory
upsAdvTestBatteryInterval
OBJECT-TYPE
The UPS system's automatic battery test period.
1.3.6.1.4.1.318.1.1.1.7.2.10DisplayStringread-writemandatory
upsAdvTestCalibrationLastSuccessfulDate
OBJECT-TYPE
The latest date when the UPS performed a successful runtime calibration test. The format is YYYY-MM-DD
1.3.6.1.4.1.318.1.1.1.7.2.11DisplayStringread-onlymandatory
upsAdvTestBatteryLastSuccessfulDate
OBJECT-TYPE
The latest date when the UPS performed a successful battery diagnostic test (battery monitoring test). The format is YYYY-MM-DD
1.3.6.1.4.1.318.1.1.1.7.2.12DisplayStringread-onlymandatory
upsAdvTestBatteryLastDate
OBJECT-TYPE
The latest date when the UPS performed a battery diagnostic test (battery monitoring test), regardless of the test result. The format is YYYY-MM-DD
1.3.6.1.4.1.318.1.1.1.7.2.13DisplayStringread-onlyoptional
upsAdvTestBatteryProcessStatus
OBJECT-TYPE
The results of the latest battery diagnostic test (battery monitoring test). ok(1) indicates a successful completion of the test. preconditionNotMeet(2) indicates that the test did not start, due to low capacity or low load. batteryTestInProgress(3) indicates that a test is in progress. refused(4) indicates that the test was refused and did not take place. aborted(5) indicates that the test started but it was either cancelled or the system encountered an error. pending(6) the test will commence shortly.
1.3.6.1.4.1.318.1.1.1.7.2.14INTEGER {ok(1), preconditionNotMeet(2), batteryTestInProgress(3), refused(4), aborted(5), pending(6), unknown(7)}read-onlymandatory
upsAdvTestBatteryConditionStatus
OBJECT-TYPE
Result of the latest successful test 1 = unknown 2 = battery OK 3 = battery capacity decreased 4 = battery defect
1.3.6.1.4.1.318.1.1.1.7.2.15INTEGER {unknown(1), batteryOK(2), batteryCapacityDecreased(3), batteryDefect(4)}read-onlymandatory
upsAdvTestDiagnosticsBatteryInterval
OBJECT-TYPE
The battery test is a diagnostic test (also referred to as battery monitoring test). The test will be performed on the day stated in upsAdvTestDiagnosticDay and at the time stated in upsAdvTestDiagnosticTime. The result can be read in upsAdvTestBatteryConditionStatus. 1 = Never 2 = Weekly 3 = biweekly 4 = Every 4 weeks 5 = Every 8 weeks 6 = Every 12 weeks 7 = Every 26 weeks 8 = Every 52 weeks
1.3.6.1.4.1.318.1.1.1.7.2.16INTEGER {never(1), weekly(2), biweekly(3), every4weeks(4), every8weeks(5), every12weeks(6), every26weeks(7), every52weeks(8)}read-onlymandatory
upsComm
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.8
upsCommStatus
OBJECT-TYPE
The status of agent's communication with UPS.
1.3.6.1.4.1.318.1.1.1.8.1INTEGER {ok(1), noComm(2)}read-onlymandatory
upsPhase
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.9
upsPhaseResetValues
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.9.1
upsPhaseResetMaxMinValues
OBJECT-TYPE
Reset the maximum and minimum UPS values: upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage, upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent, upsPhaseInputMaxPower, upsPhaseInputMinPower, upsPhaseOutputMaxCurrent, upsPhaseOutputMinCurrent, upsPhaseOutputMaxLoad, upsPhaseOutputMinLoad, upsPhaseOutputMaxPercentLoad, upsPhaseOutputMinPercentLoad, upsPhaseOutputMaxPower, upsPhaseOutputMinPower, upsPhaseOutputMaxPercentPower, upsPhaseOutputMinPercentPower.
1.3.6.1.4.1.318.1.1.1.9.1.1INTEGER {none(1), reset(2)}read-writemandatory
upsPhaseInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.9.2
upsPhaseNumInputs
OBJECT-TYPE
The number of input feeds to this device. This variable indicates the number of rows in the input table.
1.3.6.1.4.1.318.1.1.1.9.2.1INTEGERread-onlymandatory
upsPhaseInputTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs.
1.3.6.1.4.1.318.1.1.1.9.2.2not-accessiblemandatory
upsPhaseInputEntry
OBJECT-TYPE
An entry containing information applicable to a particular input.
1.3.6.1.4.1.318.1.1.1.9.2.2.1not-accessiblemandatory
upsPhaseInputTableIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.1.9.2.2.1.1INTEGERread-onlymandatory
upsPhaseNumInputPhases
OBJECT-TYPE
The number of input phases utilized in this device. The sum of all the upsPhaseNumInputPhases variable indicates the number of rows in the input phase table.
1.3.6.1.4.1.318.1.1.1.9.2.2.1.2INTEGERread-onlymandatory
upsPhaseInputVoltageOrientation
OBJECT-TYPE
The input voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
1.3.6.1.4.1.318.1.1.1.9.2.2.1.3INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)}read-onlymandatory
upsPhaseInputFrequency
OBJECT-TYPE
The input frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.2.2.1.4INTEGERread-onlymandatory
upsPhaseInputType
OBJECT-TYPE
The input type.
1.3.6.1.4.1.318.1.1.1.9.2.2.1.5INTEGER {unknown(1), main(2), bypass(3)}read-onlymandatory
upsPhaseInputName
OBJECT-TYPE
A name given to a particular input.
1.3.6.1.4.1.318.1.1.1.9.2.2.1.6DisplayStringread-writemandatory
upsPhaseInputPhaseTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the sum of the upsPhaseNumInputPhases.
1.3.6.1.4.1.318.1.1.1.9.2.3not-accessiblemandatory
upsPhaseInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase.
1.3.6.1.4.1.318.1.1.1.9.2.3.1not-accessiblemandatory
upsPhaseInputPhaseTableIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.1INTEGERread-onlymandatory
upsPhaseInputPhaseIndex
OBJECT-TYPE
The input phase identifier.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.2INTEGERread-onlymandatory
upsPhaseInputVoltage
OBJECT-TYPE
The input voltage in VAC, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.3INTEGERread-onlymandatory
upsPhaseInputMaxVoltage
OBJECT-TYPE
The maximum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.4INTEGERread-onlymandatory
upsPhaseInputMinVoltage
OBJECT-TYPE
The minimum input voltage in VAC measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.5INTEGERread-onlymandatory
upsPhaseInputCurrent
OBJECT-TYPE
The input current in 0.1 amperes, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.6INTEGERread-onlymandatory
upsPhaseInputMaxCurrent
OBJECT-TYPE
The maximum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.7INTEGERread-onlymandatory
upsPhaseInputMinCurrent
OBJECT-TYPE
The minimum input current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.8INTEGERread-onlymandatory
upsPhaseInputPower
OBJECT-TYPE
The input power in Watts, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.9INTEGERread-onlymandatory
upsPhaseInputMaxPower
OBJECT-TYPE
The maximum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.10INTEGERread-onlymandatory
upsPhaseInputMinPower
OBJECT-TYPE
The minimum input power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.11INTEGERread-onlymandatory
upsPhaseInputApparentPower
OBJECT-TYPE
The input apparent power of the UPS in kVA.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.12INTEGERread-onlymandatory
upsPhaseInputPowerFactor
OBJECT-TYPE
The input power factor measured in hundredth.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.13INTEGERread-onlymandatory
upsPhaseInputVoltagePN
OBJECT-TYPE
The input voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.2.3.1.14INTEGERread-onlymandatory
upsPhaseOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.9.3
upsPhaseNumOutputs
OBJECT-TYPE
The number of output feeds to this device. This variable indicates the number of rows in the output table.
1.3.6.1.4.1.318.1.1.1.9.3.1INTEGERread-onlymandatory
upsPhaseOutputTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the value of upsOutputNumPhases.
1.3.6.1.4.1.318.1.1.1.9.3.2not-accessiblemandatory
upsPhaseOutputEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.1.9.3.2.1not-accessiblemandatory
upsPhaseOutputTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.1.9.3.2.1.1INTEGERread-onlymandatory
upsPhaseNumOutputPhases
OBJECT-TYPE
The number of output phases utilized in this device. The sum of all the upsPhaseNumOutputPhases variable indicates the number of rows in the output phase table.
1.3.6.1.4.1.318.1.1.1.9.3.2.1.2INTEGERread-onlymandatory
upsPhaseOutputVoltageOrientation
OBJECT-TYPE
The output voltage orientation: 1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
1.3.6.1.4.1.318.1.1.1.9.3.2.1.3INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)}read-onlymandatory
upsPhaseOutputFrequency
OBJECT-TYPE
The output frequency in 0.1 Hertz, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.2.1.4INTEGERread-onlymandatory
upsPhaseOutputPhaseTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases.
1.3.6.1.4.1.318.1.1.1.9.3.3not-accessiblemandatory
upsPhaseOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular output phase.
1.3.6.1.4.1.318.1.1.1.9.3.3.1not-accessiblemandatory
upsPhaseOutputPhaseTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.1INTEGERread-onlymandatory
upsPhaseOutputPhaseIndex
OBJECT-TYPE
The output phase identifier.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.2INTEGERread-onlymandatory
upsPhaseOutputVoltage
OBJECT-TYPE
The output voltage in VAC, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.3INTEGERread-onlymandatory
upsPhaseOutputCurrent
OBJECT-TYPE
The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.4INTEGERread-onlymandatory
upsPhaseOutputMaxCurrent
OBJECT-TYPE
The maximum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.5INTEGERread-onlymandatory
upsPhaseOutputMinCurrent
OBJECT-TYPE
The minimum output current in 0.1 amperes measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.6INTEGERread-onlymandatory
upsPhaseOutputLoad
OBJECT-TYPE
The output load in VA, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.7INTEGERread-onlymandatory
upsPhaseOutputMaxLoad
OBJECT-TYPE
The maximum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.8INTEGERread-onlymandatory
upsPhaseOutputMinLoad
OBJECT-TYPE
The minimum output load in VA measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.9INTEGERread-onlymandatory
upsPhaseOutputPercentLoad
OBJECT-TYPE
The percentage of the UPS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.10INTEGERread-onlymandatory
upsPhaseOutputMaxPercentLoad
OBJECT-TYPE
The maximum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.11INTEGERread-onlymandatory
upsPhaseOutputMinPercentLoad
OBJECT-TYPE
The minimum percentage of the UPS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.12INTEGERread-onlymandatory
upsPhaseOutputPower
OBJECT-TYPE
The output power in Watts, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.13INTEGERread-onlymandatory
upsPhaseOutputMaxPower
OBJECT-TYPE
The maximum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.14INTEGERread-onlymandatory
upsPhaseOutputMinPower
OBJECT-TYPE
The minimum output power in Watts measured since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.15INTEGERread-onlymandatory
upsPhaseOutputPercentPower
OBJECT-TYPE
The percentage of the UPS power capacity in Watts at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.16INTEGERread-onlymandatory
upsPhaseOutputMaxPercentPower
OBJECT-TYPE
The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.17INTEGERread-onlymandatory
upsPhaseOutputMinPercentPower
OBJECT-TYPE
The maximum percentage of the UPS power capacity in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.18INTEGERread-onlymandatory
upsPhaseOutputPowerFactor
OBJECT-TYPE
The Output power factor of the UPS in hundredth.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.19INTEGERread-onlymandatory
upsPhaseOutputApparentPower
OBJECT-TYPE
Apparent power in kVA
1.3.6.1.4.1.318.1.1.1.9.3.3.1.20INTEGERread-onlymandatory
upsPhaseOutputInverterVoltage
OBJECT-TYPE
Output voltage in VAC measured at the output of inverter.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.21INTEGERread-onlymandatory
upsPhaseOutputVoltagePN
OBJECT-TYPE
The output voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.9.3.3.1.22INTEGERread-onlymandatory
upsSyncCtrlGroup
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.10
upsSyncCtrlGroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.10.1
upsSCGMembershipGroupNumber
OBJECT-TYPE
The SCG Membership Group number (MGN) is a 16-bit number allowing up to 65534 separate groups that can be identified and distinguished per IP subnet. Zero and 65535 are not used. The MGN is used in all communication between members of the SCG and a Network Management Card (NMC) will listen and only respond to commands sent to it using its configured SCG ID.
1.3.6.1.4.1.318.1.1.1.10.1.1INTEGERread-writemandatory
upsSCGActiveMembershipStatus
OBJECT-TYPE
Membership in the configured SCG can be enabled and disabled. If an NMC is configured for an SCG, but has its membership disabled, all synchronized control commands received will be ignored.
1.3.6.1.4.1.318.1.1.1.10.1.2INTEGER {enabledSCG(1), disabledSCG(2)}read-writemandatory
upsSCGPowerSynchronizationDelayTime
OBJECT-TYPE
The Power Synchronization Delay Time (PSD) setting is the maximum number of seconds an SCG Initiator will wait for all SCG members to recover utility power before completing the reboot sequence of a reboot or sleep command. If all SCG members are ready to proceed, no additional delay is introduced.
1.3.6.1.4.1.318.1.1.1.10.1.3INTEGERread-writemandatory
upsSCGReturnBatteryCapacityOffset
OBJECT-TYPE
A reboot command uses the Initiator's Return battery Capacity (RBC) to control when the SCG completes this operation. In a Normal Control Operation (NCC) the UPS will only complete the reboot if RBC is reached. Due to normal battery charge rate variations it may be desirable for the Followers to complete the reboot if they are within some range of the Initiator's RBC when the Initiator is prepared (charged to RBC) to complete the reboot. The Return Battery Capacity Offset (RBCO) defines a percent battery capacity subtracted from an RBC above which a Follower's battery must be charged for it to complete a reboot. For example, if the Initiator's RBC is 50% and the Initiator's RBCO is 5% then a Follower's battery capacity is within range if it is greater or equal to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot command. The default RBCO is 10%.
1.3.6.1.4.1.318.1.1.1.10.1.4INTEGERread-writemandatory
upsSCGMultiCastIP
OBJECT-TYPE
The MultiCast IP address of the SCG Group.
1.3.6.1.4.1.318.1.1.1.10.1.5IpAddressread-writemandatory
upsSyncCtrlGroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.10.2
upsSCGNumOfGroupMembers
OBJECT-TYPE
The number of active, communicating members in the Sync Control Group (SCG). This variable indicates the number of rows in the SCG Status Table.
1.3.6.1.4.1.318.1.1.1.10.2.1INTEGERread-onlymandatory
upsSCGStatusTable
OBJECT-TYPE
A list of SCG status table entries. The number of entries is given by the value of upsSCGNumOfGroupMembers.
1.3.6.1.4.1.318.1.1.1.10.2.2not-accessiblemandatory
upsSCGStatusEntry
OBJECT-TYPE
An entry containing information applicable to a particular SCG Member.
1.3.6.1.4.1.318.1.1.1.10.2.2.1not-accessiblemandatory
upsSCGStatusTableIndex
OBJECT-TYPE
The index of a status entry for an active, communicating SCG member.
1.3.6.1.4.1.318.1.1.1.10.2.2.1.1INTEGERread-onlymandatory
upsSCGMemberIP
OBJECT-TYPE
The IP address of an active, communicating SCG Member.
1.3.6.1.4.1.318.1.1.1.10.2.2.1.2IpAddressread-onlymandatory
upsSCGACInputStatus
OBJECT-TYPE
This OID indicates the AC Input Status of the SCG Member. acInGood(1) indicates the AC Input is within tolerance. acInBad(2) indicates the AC Input is not within tolerance.
1.3.6.1.4.1.318.1.1.1.10.2.2.1.3INTEGER {acInGood(1), acInBad(2)}read-onlymandatory
upsSCGACOutputStatus
OBJECT-TYPE
This OID indicates the AC Output Status of the SCG Member. acOutOn(1) indicates the UPS output is providing power to the load. acOutOff(2) indicates the UPS output is not providing power to the load.
1.3.6.1.4.1.318.1.1.1.10.2.2.1.4INTEGER {acOutOn(1), acOutOff(2)}read-onlymandatory
upsState
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.11
upsBasicState
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.11.1
upsBasicStateOutputState
OBJECT-TYPE
An ASCII string containing the 64 flags representing the current state(s) of the UPS. If the Network Card is unable to determine the state of the UPS, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 64, read from left to right. The flags are defined as follows: Flag 1: Abnormal Condition Present Flag 2: On Battery Flag 3: Low Battery Flag 4: On Line Flag 5: Replace Battery Flag 6: Serial Communication Established Flag 7: AVR Boost Active Flag 8: AVR Trim Active Flag 9: Overload Flag 10: Runtime Calibration Flag 11: Batteries Discharged Flag 12: Manual Bypass Flag 13: Software Bypass Flag 14: In Bypass due to Internal Fault Flag 15: In Bypass due to Supply Failure Flag 16: In Bypass due to Fan Failure Flag 17: Sleeping on a Timer Flag 18: Sleeping until Utility Power Returns Flag 19: On Flag 20: Rebooting Flag 21: Battery Communication Lost Flag 22: Graceful Shutdown Initiated Flag 23: Smart Boost or Smart Trim Fault Flag 24: Bad Output Voltage Flag 25: Battery Charger Failure Flag 26: High Battery Temperature Flag 27: Warning Battery Temperature Flag 28: Critical Battery Temperature Flag 29: Self Test In Progress Flag 30: Low Battery / On Battery Flag 31: Graceful Shutdown Issued by Upstream Device Flag 32: Graceful Shutdown Issued by Downstream Device Flag 33: No Batteries Attached Flag 34: Synchronized Command is in Progress Flag 35: Synchronized Sleeping Command is in Progress Flag 36: Synchronized Rebooting Command is in Progress Flag 37: Inverter DC Imbalance Flag 38: Transfer Relay Failure Flag 39: Shutdown or Unable to Transfer Flag 40: Low Battery Shutdown Flag 41: Electronic Unit Fan Failure Flag 42: Main Relay Failure Flag 43: Bypass Relay Failure Flag 44: Temporary Bypass Flag 45: High Internal Temperature Flag 46: Battery Temperature Sensor Fault Flag 47: Input Out of Range for Bypass Flag 48: DC Bus Overvoltage Flag 49: PFC Failure Flag 50: Critical Hardware Fault Flag 51: Green Mode/ECO Mode Flag 52: Hot Standby Flag 53: Emergency Power Off (EPO) Activated Flag 54: Load Alarm Violation Flag 55: Bypass Phase Fault Flag 56: UPS Internal Communication Failure Flag 57: Efficiency Booster Mode Flag 58: Off Flag 59: Standby Flag 60: Minor or Environment Alarm Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.1.1DisplayStringread-onlymandatory
upsBasicStateAlarmStatus
OBJECT-TYPE
The alarm status of the Power Module. noAlarms(1) indicates the device has no alarms present. infoAlarm (2) indicates the device has alarms and the highest severity of the alarms present is infomational. warningAlarm (3) indicates the device has alarms and the highest severity of the alarms present is warning. criticalAlarm (4) indicates the device has alarms and the highest severity of the alarms present is critical.
1.3.6.1.4.1.318.1.1.1.11.1.2INTEGER {noAlarms(1), infoAlarm(2), warningAlarm(3), criticalAlarm(4)}read-onlymandatory
upsAdvState
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.11.2
upsAdvStateAbnormalConditions
OBJECT-TYPE
An ASCII string containing the 32 flags representing the current active UPS faults. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If this variable is not supported by the connected UPS, this variable is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 32, and read from left to right. The flags are defined as follows: Flag 1: Power Module Failure Flag 2: Main Intelligence Module Failure Flag 3: Redundant Intelligence Module Failure Flag 4: Battery Failure Flag 5: Load(kVA) Alarm Threshold Violation Flag 6: Redundancy Lost Flag 7: Redundancy Below Alarm Threshold Flag 8: Bypass not in Range; Either Frequency or Voltage Flag 9: Bypass Contactor Stuck in Bypass Condition Flag 10: Bypass Contactor Stuck in On-Line Condition Flag 11: In Bypass due to an Internal Fault Flag 12: In Bypass due to an Overload Flag 13: In Maintenance Bypass Flag 14: Input Circuit Braker Tripped Open Flag 15: System Level Fan Failure Flag 16: Redundant Intelligent Module in Control Flag 17: IIC Inter-Module Communication Failure Flag 18: No Working Power Modules Flag 19: Load Shutdown From Bypass; Input Frequency Flag 20: Runtime Below Alarm Threshold Flag 21: Extended Run Frame Fault Flag 22: Output Voltage out of Range Flag 23: UPS Not Synchronized Flag 24: No Batteries Installed Flag 25: Battery Voltage High Flag 26: UPS Specific Fault Detected Flag 27: Site Wiring Fault Flag 28: Backfeed Protection Relay Opened Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.2.1DisplayStringread-onlymandatory
upsAdvStateSymmetra3PhaseSpecificFaults
OBJECT-TYPE
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra 3-Phase UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: External Switch Gear Failure Flag 2: External Transformer Over Temperature Flag 3: External DC Circuit Breaker Tripped Flag 4: System Power Supply Failure Flag 5: Battery Monitor Card Failure Flag 6: Battery Monitor Card Removed Flag 7: XR Communication Card Failure Flag 8: XR Communication Card Removed Flag 9: External Switch Gear Monitoring Card Failure Flag 10: External Switch Gear Monitoring Card Removed Flag 11: Internal DC Circuit Breaker Tripped Flag 12: Static Bypass Switch Failure Flag 13: System EEPROM Removed Flag 14: System EEPROM Failure Flag 15: UPS in Forced Bypass Flag 16: Static Bypass Switch Module Removed Flag 17: System Start-Up Configuration Fault Flag 18: Battery Charger Shutdown Externally Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> Flag 33: <Not Used> Flag 34: <Not Used> Flag 35: <Not Used> Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: <Not Used> Flag 47: <Not Used> Flag 48: <Not Used> Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.2.2DisplayStringread-onlymandatory
upsAdvStateDP300ESpecificFaults
OBJECT-TYPE
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Silcon DP300E UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: Peak Current Limiter Active Flag 2: Bypass Power Supply Fault Flag 3: Delta Current Limiter Active Flag 4: Fan Fault Flag 5: High DC warning Flag 6: Inverter Voltage Error Flag 7: Parallel Synchronization Error Flag 8: Second Power Supply Fault Flag 9: Internal Power Supply Fault Flag 10: <Not Used> Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: Bypass Static Switch High Temperature Flag 15: High Battery Temperature Flag 16: Battery Weak Flag 17: <Not Used> Flag 18: System Locked in Operation Mode Flag 19: RAM1 Memory Write Error Flag 20: Memory Write Error Flag 21: Communication to VQ Bypass Lost Flag 22: Communication to VQ Output Lost Flag 23: Communication to DMU Lost Flag 24: Communication to Controller Lost Flag 25: Communication to Parallel IF Lost Flag 26: External Shutdown Accepted Flag 27: DC Capacitor Charge Error Flag 28: Communication to VQ Mains Lost Flag 29: Bypass Synchronization Error Flag 30: Charge Error Flag 31: SII Aux Input Activiated Flag 32: <Not Used> Flag 33: Blown Inverter Fuse Flag 34: Blown Rectifier Fuse Flag 35: Auxilliary 1 Fault Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: High Temperature Charger Magnetic Flag 47: <Not Used> Flag 48: Battery Monitor Warning Flag 49: Battery Monitor Alarm Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: TSM 1/2/3 Temperature Shutdown Flag 54: Charger 0/30 Temperature Warning Flag 55: Charger 0/30 Temperature Shutdown Flag 56: High Output Voltage Flag 57: SSW Temperature Over 90 Flag 58: <Not Used> Flag 59: Low Current Failure In AC Capacitors Flag 60: <Not Used> Flag 61: Advanced Battery Management Not Installed Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.2.3DisplayStringread-onlymandatory
upsAdvStateSymmetraSpecificFaults
OBJECT-TYPE
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Symmetra UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: System Fault Flag 2: Bypass Relay Fault Flag 3: Power Module Turn Off Failure Flag 4: Frame Identification Fault Flag 5: <Not Used> Flag 6: <Not Used> Flag 7: <Not Used> Flag 8: <Not Used> Flag 9: <Not Used> Flag 10: <Not Used> Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used> Flag 17: <Not Used> Flag 18: <Not Used> Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> Flag 33: <Not Used> Flag 34: <Not Used> Flag 35: <Not Used> Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: <Not Used> Flag 47: <Not Used> Flag 48: <Not Used> Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.2.4DisplayStringread-onlymandatory
upsAdvStateSmartUPSSpecificFaults
OBJECT-TYPE
An ASCII string containing the 64 flags representing the current active UPS specific faults for the Smart-UPS UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: EPO Switch Activated Flag 2: Static Bypass Switch Fault Flag 3: System Configuration Fault Flag 4: Power Supply Unit Fault Flag 5: Weak Battery Flag 6: High Battery Temperature Flag 7: Internal Mechanical Bypass Flag 8: Loss Of Parallel Redundancy Flag 9: Parallel Bus Communication Fault on Cable 1 Flag 10: Parallel Bus Communication Fault on Cable 2 Flag 11: Auxiliary Bus Communication Fault Flag 12: Parallel Bus Termination Fault on Cable 1 Flag 13: Parallel Bus Termination Fault on Cable 2 Flag 14: Auxiliary Bus Termination Fault Flag 15: No Master Present In The Parallel System Flag 16: Overload on a Parallel Unit Flag 17: Parallel Configuration Fault Flag 18: <Not Used> Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used> Flag 33: <Not Used> Flag 34: <Not Used> Flag 35: <Not Used> Flag 36: <Not Used> Flag 37: <Not Used> Flag 38: <Not Used> Flag 39: <Not Used> Flag 40: <Not Used> Flag 41: <Not Used> Flag 42: <Not Used> Flag 43: <Not Used> Flag 44: <Not Used> Flag 45: <Not Used> Flag 46: <Not Used> Flag 47: <Not Used> Flag 48: <Not Used> Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.2.5DisplayStringread-onlymandatory
upsAdvStateSystemMessages
OBJECT-TYPE
An ASCII string containing the 3 digit Decimal code representing the current active message from the System Message Register. Each code should remain active for a minimum of 15 seconds. However, in the worst case scenario, a code could be cleared after only 5 seconds. It is recommended that this object be polled at least once every 4 seconds in order to get the most accurate representation of the current UPS System Message. If the Network Card is unable to determine the value of the System Message Register, this variable is set to 'UNKNOWN'.
1.3.6.1.4.1.318.1.1.1.11.2.6DisplayStringread-onlymandatory
upsAdvStateTotaltimeonbattery
OBJECT-TYPE
Total time the UPS has been in battery operation.
1.3.6.1.4.1.318.1.1.1.11.2.7DisplayStringread-onlymandatory
upsAdvStateTotaltimeonbypass
OBJECT-TYPE
Total time the UPS has been in bypass operation.
1.3.6.1.4.1.318.1.1.1.11.2.8DisplayStringread-onlymandatory
upsAdvStateTotaltimeonNormal
OBJECT-TYPE
Total time the UPS has been in normal operation.
1.3.6.1.4.1.318.1.1.1.11.2.9DisplayStringread-onlymandatory
upsAdvStateNumberoftimesonbattery
OBJECT-TYPE
Number of times the UPS was on battery. Since the last reset of statistical data.
1.3.6.1.4.1.318.1.1.1.11.2.10INTEGERread-onlymandatory
upsAdvStateNumberoftimesbypass
OBJECT-TYPE
Number of times the UPS was in bypass. Since the last reset of statistical data.
1.3.6.1.4.1.318.1.1.1.11.2.11INTEGERread-onlymandatory
upsAdvStateNumberoftimesNormal
OBJECT-TYPE
Number of times the UPS was in normal operation. Since the last reset of statistical data.
1.3.6.1.4.1.318.1.1.1.11.2.12INTEGERread-onlymandatory
upsAdvStateEcomode
OBJECT-TYPE
Eco mode status. 1: UPS is on Eco-mode 2: UPS is not on Eco-mode.
1.3.6.1.4.1.318.1.1.1.11.2.13INTEGER {upsOnEcoMode(1), upsNotOnEcoMode(2)}read-onlymandatory
upsAdvStateLifeCycleManagement
OBJECT-TYPE
An ASCII string containing the 16 flags representing the life cycle management alerts for the device. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 16, and read from left to right. The bits are defined as follows: Flag 1: End of Warranty Soon Flag 2: Battery Check Recommended Flag 3: Service Period On Wearing Parts Expired Flag 4: Secure Start-up Recommended Flag 5: Fan Life Expired Flag 6: DC Capacitor Life Expired Flag 7: AC Capacitor Life Expired Flag 8: Supply Service Life Expired Flag 9: Ups Out Of Limits Warning Flag 10: Air Filter Life Expired Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used>
1.3.6.1.4.1.318.1.1.1.11.2.14DisplayStringread-onlymandatory
upsOutletGroups
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.12
upsOutletGroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.12.1
upsOutletGroupStatusTableSize
OBJECT-TYPE
The number of outlet groups for the UPS.
1.3.6.1.4.1.318.1.1.1.12.1.1INTEGERread-onlymandatory
upsOutletGroupStatusTable
OBJECT-TYPE
Allows for getting status of the outlet groups. The number of entries is contained in the upsOutletGroupStatusTableSize OID.
1.3.6.1.4.1.318.1.1.1.12.1.2not-accessiblemandatory
upsOutletGroupStatusEntry
OBJECT-TYPE
The outlet group status to get.
1.3.6.1.4.1.318.1.1.1.12.1.2.1not-accessiblemandatory
upsOutletGroupStatusIndex
OBJECT-TYPE
The index to the outlet group entry.
1.3.6.1.4.1.318.1.1.1.12.1.2.1.1INTEGERread-onlymandatory
upsOutletGroupStatusName
OBJECT-TYPE
The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID.
1.3.6.1.4.1.318.1.1.1.12.1.2.1.2DisplayStringread-onlymandatory
upsOutletGroupStatusGroupState
OBJECT-TYPE
Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupStatusOn (1) value will be returned. If the outlet group is off, the upsOutletGroupStatusOff (2) value will be returned. If the state of the outlet group cannot be determined, the upsOutletGroupStatusUnknown (3) value will be returned.
1.3.6.1.4.1.318.1.1.1.12.1.2.1.3INTEGER {upsOutletGroupStatusOn(1), upsOutletGroupStatusOff(2), upsOutletGroupStatusUnknown(3)}read-onlymandatory
upsOutletGroupStatusCommandPending
OBJECT-TYPE
Getting this variable will return the command pending state of the outlet group. If a command is pending on the outlet group, the upsOutletGroupCommandPending (1) value will be returned. If there is not a command pending on the outlet group, the upsOutletGroupNoCommandPending (2) will be returned.
1.3.6.1.4.1.318.1.1.1.12.1.2.1.4INTEGER {upsOutletGroupCommandPending(1), upsOutletGroupNoCommandPending(2)}read-onlymandatory
upsOutletGroupStatusOutletType
OBJECT-TYPE
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail.
1.3.6.1.4.1.318.1.1.1.12.1.2.1.5INTEGER {upsSwitchedOutletGroup(1), upsMainOutletGroup(2)}read-onlymandatory
upsOutletGroupStatusGroupFullState
OBJECT-TYPE
An ASCII string containing the 32 flags representing the current state(s) of the outlet group. If the Network Card is unable to determine the state of the outlet group, this variable is set to 'UNKNOWN'. The flags are numbered from 1 to 32, and read from left to right. The flags are defined as follows: Flag 1: On Flag 2: Off Flag 3: Reboot in Progress Flag 4: Shutdown in Progress Flag 5: Sleep in Progress Flag 6: <Not Used> Flag 7: <Not Used> Flag 8: Pending Load Shed Flag 9: Pending On Delay Flag 10: Pending Off Delay Flag 11: Pending AC Presence Flag 12: Pending On Minimum Runtime Flag 13: Member Group Process 1 Flag 14: Member Group Process 2 Flag 15: Runtime Below Turn On Setting Flag 16: <Not Used> Flag 17: <Not Used> Flag 18: <Not Used> Flag 19: <Not Used> Flag 20: <Not Used> Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used>
1.3.6.1.4.1.318.1.1.1.12.1.2.1.6DisplayStringread-onlymandatory
upsOutletGroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.12.2
upsOutletGroupConfigTableSize
OBJECT-TYPE
The number of outlet groups for the UPS.
1.3.6.1.4.1.318.1.1.1.12.2.1INTEGERread-onlymandatory
upsOutletGroupConfigTable
OBJECT-TYPE
The list of outlet groups to configure. The number of entries is defined by the upsOutletGroupConfigTableSize OID.
1.3.6.1.4.1.318.1.1.1.12.2.2not-accessiblemandatory
upsOutletGroupConfigEntry
OBJECT-TYPE
The outlet groups to configure.
1.3.6.1.4.1.318.1.1.1.12.2.2.1not-accessiblemandatory
upsOutletGroupConfigIndex
OBJECT-TYPE
The index to the outlet group entry.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.1INTEGERread-onlymandatory
upsOutletGroupConfigName
OBJECT-TYPE
The name of the outlet group.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.2DisplayStringread-writemandatory
upsOutletGroupConfigPowerOnDelay
OBJECT-TYPE
The amount of time (seconds) the outlet group will delay powering on when the delayed on, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the UPS and the outlet group.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.3INTEGERread-writemandatory
upsOutletGroupConfigPowerOffDelay
OBJECT-TYPE
The amount of time (seconds) the outlet group will delay powering off when the delayed off, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the UPS and the outlet group.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.4INTEGERread-writemandatory
upsOutletGroupConfigRebootDuration
OBJECT-TYPE
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait (seconds) after turning the power off, at the start of the sequence, before initiating the power on sequence. Allowed values vary by UPS model.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.5INTEGERread-writemandatory
upsOutletGroupConfigMinReturnRuntime
OBJECT-TYPE
In an Outlet Group shutdown sequence, the Outlet Group cycles power off then on. This OID defines the minimum amount of UPS runtime (seconds) that is required in order to power the Outlet Group on. Allowed values vary by UPS model.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.6INTEGERread-writemandatory
upsOutletGroupConfigOutletType
OBJECT-TYPE
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.7INTEGER {upsSwitchedOutletGroup(1), upsMainOutletGroup(2)}read-onlymandatory
upsOutletGroupConfigLoadShedControlSkipOffDelay
OBJECT-TYPE
Configures whether the outlet group's off delay setting (upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situation, where applicable.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.8INTEGER {upsOutletGroupConfigSkipOffDelay(1), upsOutletGroupConfigUseOffDelay(2)}read-writemandatory
upsOutletGroupConfigLoadShedControlAutoRestart
OBJECT-TYPE
Configures whether the outlet group will automatically restart after a load shedding situation, where applicable.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.9INTEGER {upsOutletGroupConfigAutoRestart(1), upsOutletGroupConfigManualRestart(2)}read-writemandatory
upsOutletGroupConfigLoadShedControlTimeOnBattery
OBJECT-TYPE
Configures whether the outlet group will load shed (turn off) after the UPS's time on battery has exceeded the upsOutletGroupConfigLoadShedTimeOnBattery OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.10INTEGER {upsOutletGroupConfigDisableTimeOnBatteryLoadShed(1), upsOutletGroupConfigEnableTimeOnBatteryLoadShed(2)}read-writemandatory
upsOutletGroupConfigLoadShedControlRuntimeRemaining
OBJECT-TYPE
Configures whether the outlet group will load shed (turn off) when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShedRuntimeRemaining OID setting. The settings for upsOutletGroupConfigLoadShedControlSkipOffDelay and upsOutletGroupConfigLoadShedControlAutoRestart are valid for this load shed condition.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.11INTEGER {upsOutletGroupConfigDisableRuntimeRemainingLoadShed(1), upsOutletGroupConfigEnableRuntimeRemainingLoadShed(2)}read-writemandatory
upsOutletGroupConfigLoadShedControlInOverload
OBJECT-TYPE
Configures whether the outlet group will load shed (turn off) when the UPS is in an overload condition. The setting for upsOutletGroupConfigLoadShedControlSkipOffDelay is valid for this load shed condition. Returns -1 if not supported by this outlet group.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.12INTEGER {upsOutletGroupConfigDisableInOverloadLoadShed(1), upsOutletGroupConfigEnableInOverloadLoadShed(2)}read-writemandatory
upsOutletGroupConfigLoadShedTimeOnBattery
OBJECT-TYPE
When the UPS has been on battery for more time than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlTimeOnBattery OID. Allowed values vary by UPS model.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.13INTEGERread-writemandatory
upsOutletGroupConfigLoadShedRuntimeRemaining
OBJECT-TYPE
When the runtime remaining is less than this value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlRuntimeRemaining OID. Allowed values vary by UPS model.
1.3.6.1.4.1.318.1.1.1.12.2.2.1.14INTEGERread-writemandatory
upsOutletGroupControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.12.3
upsOutletGroupControlTableSize
OBJECT-TYPE
The number of outlet groups for the UPS.
1.3.6.1.4.1.318.1.1.1.12.3.1INTEGERread-onlymandatory
upsOutletGroupControlTable
OBJECT-TYPE
Allows for control of individual outlet groups. The number of entries is contained in the upsOutletGroupControlTableSize OID.
1.3.6.1.4.1.318.1.1.1.12.3.2not-accessiblemandatory
upsOutletGroupControlEntry
OBJECT-TYPE
The outlet group to control.
1.3.6.1.4.1.318.1.1.1.12.3.2.1not-accessiblemandatory
upsOutletGroupControlIndex
OBJECT-TYPE
The index to the outlet group entry.
1.3.6.1.4.1.318.1.1.1.12.3.2.1.1INTEGERread-onlymandatory
upsOutletGroupControlName
OBJECT-TYPE
The name of the outlet group. This OID is provided for informational purposes only. This value is set by the upsOutletGroupConfigName OID.
1.3.6.1.4.1.318.1.1.1.12.3.2.1.2DisplayStringread-onlymandatory
upsOutletGroupControlCommand
OBJECT-TYPE
Getting this variable will return the outlet group state. If the outlet group is on, the upsOutletGroupImmediateOn (1) value will be returned. If the outlet group is off, the upsOutletGroupImmediateOff (2) value will be returned. If the state of the outlet group cannot be determined, the upsOutletGroupControlUnknown (8) value will be returned. Setting this variable to upsOutletGroupImmediateOn (1) will turn the outlet group on immediately. Setting this variable to upsOutletGroupImmediateOff (2) will turn the outlet group off immediately. Setting this variable to upsOutletGroupImmediateRebootWithOrWithoutAC (3) will turn the outlet group off immediately, wait the upsOutletGroupConfigRebootDuration OID time, wait the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on regardless of the AC input power on the UPS. Setting this variable to upsOutletGroupDelayedOn (4) will turn the outlet group on after the upsOutletGroupConfigPowerOnDelay OID has elapsed. Setting this variable to upsOutletGroupDelayedOff (5) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed. Setting this variable to upsOutletGroupDelayedRebootWithOrWithoutAC (6) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait the upsOutletGroupConfigRebootDuration OID time, wait the upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on regardless of the AC input power on the UPS. Setting this variable to upsOutletGroupCancelPendingCommand (7) will cause any pending command to this outlet group to be canceled. Setting this variable to upsOutletGroupImmediateRebootShutdown (9) will turn the outlet group off immediately, wait for the AC power to return to normal (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet group on. Setting this variable to upsOutletGroupDelayedRebootShutdown (10) will turn the outlet group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait for the AC power to return to normal (a minimum of the upsOutletGroupConfigRebootDuration OID time), wait the upsOutletGroupConfigPowerOnDelay OID time, and then turn the outlet group on. In systems with a main outlet group, commands to the main outlet group must be performed with caution. It may be clearer to use the ups control commands available from upsAdvControl... OIDs. If any command is made to the main outlet group that will turn it off, one of two things will happen: 1) If any switched outlet group is in a state that prevents this command from occurring on the main outlet group, the command will be rejected. Note that a switched outlet group being on without a command in progress is not a state that normally prevents the command. 2) The command will be accepted and applied to the main outlet group and all switched outlet groups that are on. There is one additional special case for systems with a main outlet group. If the main outlet group is off and a switched outlet group is commanded to turn on, the on command will be applied to both the main outlet group and that switched outlet group.
1.3.6.1.4.1.318.1.1.1.12.3.2.1.3INTEGER {upsOutletGroupImmediateOn(1), upsOutletGroupImmediateOff(2), upsOutletGroupImmediateRebootWithOrWithoutAC(3), upsOutletGroupDelayedOn(4), upsOutletGroupDelayedOff(5), upsOutletGroupDelayedRebootWithOrWithoutAC(6), upsOutletGroupCancelPendingCommand(7), upsOutletGroupControlUnknown(8), upsOutletGroupImmediateRebootShutdown(9), upsOutletGroupDelayedRebootShutdown(10)}read-writemandatory
upsOutletGroupControlOutletType
OBJECT-TYPE
Getting this variable will return the type of outlet group. If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main outlet group is off, all the switched outlet groups must also be off. Therefore, any commands made to the main outlet group that turn it off will also be applied to all switched outlet groups that are on, unless the state of a switched outlet group prevents it, in which case the command will fail.
1.3.6.1.4.1.318.1.1.1.12.3.2.1.4INTEGER {upsSwitchedOutletGroup(1), upsMainOutletGroup(2)}read-onlymandatory
upsDiagnostics
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13
upsDiagnosticIM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.1
upsDiagIMTableSize
OBJECT-TYPE
The number of Intelligence Modules in or attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.1.1INTEGERread-onlymandatory
upsDiagIMTable
OBJECT-TYPE
Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagIMTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.1.2not-accessiblemandatory
upsDiagIMEntry
OBJECT-TYPE
The diagnostics and information of an Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1not-accessiblemandatory
upsDiagIMIndex
OBJECT-TYPE
The index to the Intelligence Module entry.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.1INTEGERread-onlymandatory
upsDiagIMType
OBJECT-TYPE
The type of the Intelligence Module. imUnknown(1) indicates the IM type is unknown. imMIM(2) indicates the IM type is a Main Intelligence Module. imRIM(3) indicates the IM type is Redundant Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.2INTEGER {imUnknown(1), imMIM(2), imRIM(3)}read-onlymandatory
upsDiagIMStatus
OBJECT-TYPE
The status of the Intelligence Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagIMFirmwareRev
OBJECT-TYPE
The firmware revision of the Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.4DisplayStringread-onlymandatory
upsDiagIMSlaveFirmwareRev
OBJECT-TYPE
The slave firmware revision of the Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.5DisplayStringread-onlymandatory
upsDiagIMHardwareRev
OBJECT-TYPE
The hardware revision of the Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.6DisplayStringread-onlymandatory
upsDiagIMSerialNum
OBJECT-TYPE
The serial number of the Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.7DisplayStringread-onlymandatory
upsDiagIMManufactureDate
OBJECT-TYPE
The manufacture date of the Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.8DisplayStringread-onlymandatory
upsDiagIMInControl
OBJECT-TYPE
The Intelligence Module state. activeInControl(1) indicates the IM is active and in control. passive(2) indicates the IM is in passive state. unknown(3) indicates the IM is in unknown state. fault(4) indicates the IM is in fault state.
1.3.6.1.4.1.318.1.1.1.13.1.2.1.9INTEGER {activeInControl(1), passive(2), unknown(3), fault(4)}read-onlymandatory
upsDiagnosticPowerModules
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.2
upsDiagPMTableSize
OBJECT-TYPE
The maximum number of Power Modules supported by the UPS.
1.3.6.1.4.1.318.1.1.1.13.2.1INTEGERread-onlymandatory
upsDiagPMTable
OBJECT-TYPE
Allows for diagnostics of Individual Power modules. The number of entries is contained in the upsDiagPMTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.2.2not-accessiblemandatory
upsDiagPMEntry
OBJECT-TYPE
The diagnostics of an Power Module.
1.3.6.1.4.1.318.1.1.1.13.2.2.1not-accessiblemandatory
upsDiagPMIndex
OBJECT-TYPE
The index to the Power Module entry.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.1INTEGERread-onlymandatory
upsDiagPMStatus
OBJECT-TYPE
The status of the Power Module. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.2INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagPMFirmwareRev
OBJECT-TYPE
The firmware revision of the Power Module.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.3DisplayStringread-onlymandatory
upsDiagPMHardwareRev
OBJECT-TYPE
The hardware revision of the Power Module.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.4DisplayStringread-onlymandatory
upsDiagPMSerialNum
OBJECT-TYPE
The serial number of the Power Module.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.5DisplayStringread-onlymandatory
upsDiagPMManufactureDate
OBJECT-TYPE
The manufacture date of the Power Module.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.6DisplayStringread-onlymandatory
upsDiagPMModelNum
OBJECT-TYPE
The model number of the Power Module.
1.3.6.1.4.1.318.1.1.1.13.2.2.1.7DisplayStringread-onlymandatory
upsDiagPMLifetimeInfoTable
OBJECT-TYPE
Allows for diagnostics of individual power module's lifetime information. The number of entries is contained in the upsDiagPMTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.2.3not-accessiblemandatory
upsDiagPMLifetimeInfoEntry
OBJECT-TYPE
The diagnostics of a Power Module lifetime information.
1.3.6.1.4.1.318.1.1.1.13.2.3.1not-accessiblemandatory
upsDiagPMLifetimeInfoIndex
OBJECT-TYPE
The index to the Power Module lifetime information entry.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.1INTEGERread-onlymandatory
upsDiagPMLifetimeStatus
OBJECT-TYPE
The status of the Power Module lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.2INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)}read-onlymandatory
upsDiagPMEstmtdLifetimeRmng
OBJECT-TYPE
Displays the time remaining for the module before it should be replaced. Measured in months. This value is set when you originally install the module.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.3INTEGERread-onlymandatory
upsDiagPMEstmtdLifetimeRmngPct
OBJECT-TYPE
Displays the percentage of the total lifetime remaining for the module before it should be replaced.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.4INTEGERread-onlymandatory
upsDiagPMFanLifetimeStatus
OBJECT-TYPE
The status of the Power Module Fan lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.5INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)}read-onlymandatory
upsDiagPMFanEstmtdLifetimeRmng
OBJECT-TYPE
Displays the time remaining, measured in months, before the module's fan should be replaced. It is reset by the field service engineer when a new fan is installed.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.6INTEGERread-onlymandatory
upsDiagPMFanEstmtdLifetimeRmngPct
OBJECT-TYPE
Displays the percentage of the total lifetime remaining before the module's fan should be replaced.
1.3.6.1.4.1.318.1.1.1.13.2.3.1.7INTEGERread-onlymandatory
upsDiagPMEnclDoorFltrTableSize
OBJECT-TYPE
The maximum number of power module enclosures attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.2.4INTEGERread-onlymandatory
upsDiagPMEnclDoorFltrTable
OBJECT-TYPE
Allows for the diagnostics of individual power module enclosure door filters. The number of entries is contained in the upsDiagPMEnclDoorFltrTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.2.5not-accessiblemandatory
upsDiagPMEnclDoorFltrEntry
OBJECT-TYPE
Power module door filter diagnostics info.
1.3.6.1.4.1.318.1.1.1.13.2.5.1not-accessiblemandatory
upsDiagPMEnclIndex
OBJECT-TYPE
The index to the power module enclosure entry. Enclosure 0 indicates the Power enclosure 1. Enclosure 1 indicates the Power enclosure 2.
1.3.6.1.4.1.318.1.1.1.13.2.5.1.1INTEGERread-onlymandatory
upsDiagPMEnclDoorFltrLifetime
OBJECT-TYPE
Door filter replacement time interval, based on the installation enivironment. heavyFiltration15days (1) indicates door filter needs to be replaced within 15 days. normalFiltration30days (2) indicates door filter needs to be replaced within 30 days. lightFiltration60days (3) indicates door filter needs to be replaced within 60 days. notPresent(4) indicates that the door filter is not present.
1.3.6.1.4.1.318.1.1.1.13.2.5.1.2INTEGER {heavyFiltration15days(1), normalFiltration30days(2), lightFiltration60days(3), notPresent(4)}read-onlymandatory
upsDiagPMEnclDoorFltrStatus
OBJECT-TYPE
Indicates the current status of the door filter. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown.
1.3.6.1.4.1.318.1.1.1.13.2.5.1.3INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)}read-onlymandatory
upsDiagPMEnclDoorFltrEstmtdLifetimeRmng
OBJECT-TYPE
Displays the time remaining, measured in days, before the module door filter should be replaced. This value is set when you originally install the module.
1.3.6.1.4.1.318.1.1.1.13.2.5.1.4INTEGERread-onlymandatory
upsDiagPMEnclDoorFltrEstmtdLifetimeRmngPct
OBJECT-TYPE
Displays the percentage of the total lifetime remaining for the module door filter before it should be replaced.
1.3.6.1.4.1.318.1.1.1.13.2.5.1.5INTEGERread-onlymandatory
upsDiagnosticBatteries
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.3
upsDiagBatteryTableSize
OBJECT-TYPE
The maximum number of batteries supported by the UPS.
1.3.6.1.4.1.318.1.1.1.13.3.1INTEGERread-onlymandatory
upsDiagBatteryTable
OBJECT-TYPE
Allows for diagnostics of individual batteries. The number of entries is contained in the upsDiagBattTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.3.2not-accessiblemandatory
upsDiagBatteryEntry
OBJECT-TYPE
The diagnostics of a battery.
1.3.6.1.4.1.318.1.1.1.13.3.2.1not-accessiblemandatory
upsDiagBatteryFrameIndex
OBJECT-TYPE
The index to the battery frame entry. Frame 0 indicates the Main frame. Extended Run (XR) frames start from index 1.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.1INTEGERread-onlymandatory
upsDiagBatteryIndex
OBJECT-TYPE
The index to the battery entry.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.2INTEGERread-onlymandatory
upsDiagBatteryStatus
OBJECT-TYPE
The status of the battery. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the battery status is OK. failed(4) indicates the battery status is failed. highTemperature(5) indicates the battery has a high temperature condition. replaceImmediately(6) indicates the battery must be replaced immediately. lowCapacity(7) indicates the battery has a low capacity.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.3INTEGER {unknown(1), notInstalled(2), ok(3), failed(4), highTemperature(5), replaceImmediately(6), lowCapacity(7)}read-onlymandatory
upsDiagBatterySerialNumber
OBJECT-TYPE
The serial number of the battery.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.4DisplayStringread-onlymandatory
upsDiagBatteryFirmwareRev
OBJECT-TYPE
The firmware revision of the battery.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.5DisplayStringread-onlymandatory
upsDiagBatteryManufactureDate
OBJECT-TYPE
The manufacture date of the battery.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.6DisplayStringread-onlymandatory
upsDiagBatteryType
OBJECT-TYPE
The battery type or rating for the battery.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.7DisplayStringread-onlymandatory
upsDiagBatteryFramePresent
OBJECT-TYPE
The battery frame/cabinet status. 0 indicates frame/cabinet is not present. 1 indicates frame/cabinet is present.
1.3.6.1.4.1.318.1.1.1.13.3.2.1.8INTEGER {notPresent(0), present(1)}read-onlymandatory
upsDiagBatteryFrameTemperature
OBJECT-TYPE
The battery frame/cabinet temperature in tenths of degrees celsius. If the frame/cabinet is not present, this variable is set to (-1).
1.3.6.1.4.1.318.1.1.1.13.3.2.1.9INTEGERread-onlymandatory
upsDiagBatteryFrameTableSize
OBJECT-TYPE
The maximum number of battery frames supported by the UPS.
1.3.6.1.4.1.318.1.1.1.13.3.3INTEGERread-onlymandatory
upsDiagBatteryFrameTable
OBJECT-TYPE
Allows for diagnostics of individual battery frame. The number of entries is contained in the upsDiagBatteryFrameTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.3.4not-accessiblemandatory
upsDiagBatteryFrameEntry
OBJECT-TYPE
The diagnostics of a battery frame.
1.3.6.1.4.1.318.1.1.1.13.3.4.1not-accessiblemandatory
upsDiagBatteryFrameTableIndex
OBJECT-TYPE
The index to the battery frame entry.
1.3.6.1.4.1.318.1.1.1.13.3.4.1.1INTEGERread-onlymandatory
upsDiagBatteryModuleStatusPerFrame
OBJECT-TYPE
An ASCII string containing the 64 flags representing the status of battery modules. 1 indicates battery module installed, 0 indicates battery module not installed. The flags are numbered from 1 to 64, and read from left to right. The flags are defined as follows: Flag 1: Battery Module Level 1 A Flag 2: Battery Module Level 1 B Flag 3: Battery Module Level 1 C Flag 4: Battery Module Level 1 D Flag 5: Battery Module Level 1 E Flag 6: Battery Module Level 1 F Flag 7: Battery Module Level 2 A Flag 8: Battery Module Level 2 B Flag 9: Battery Module Level 2 C Flag 10: Battery Module Level 2 D Flag 11: Battery Module Level 2 E Flag 12: Battery Module Level 2 F Flag 13: Battery Module Level 3 A Flag 14: Battery Module Level 3 B Flag 15: Battery Module Level 3 C Flag 16: Battery Module Level 3 D Flag 17: Battery Module Level 3 E Flag 18: Battery Module Level 3 F Flag 19: Battery Module Level 4 A Flag 20: Battery Module Level 4 B Flag 21: Battery Module Level 4 C Flag 22: Battery Module Level 4 D Flag 23: Battery Module Level 4 E Flag 24: Battery Module Level 4 F Flag 25: Battery Module Level 7 A Flag 26: Battery Module Level 7 B Flag 27: Battery Module Level 7 C Flag 28: Battery Module Level 7 D Flag 29: Battery Module Level 7 E Flag 30: Battery Module Level 7 F Flag 31: Battery Module Level 8 A Flag 32: Battery Module Level 8 B Flag 33: Battery Module Level 8 C Flag 34: Battery Module Level 8 D Flag 35: Battery Module Level 8 E Flag 36: Battery Module Level 8 F Flag 37: Battery Module Level 9 A Flag 38: Battery Module Level 9 B Flag 39: Battery Module Level 9 C Flag 40: Battery Module Level 9 D Flag 41: Battery Module Level 9 E Flag 42: Battery Module Level 9 F Flag 43: Battery Module Level 10 A Flag 44: Battery Module Level 10 B Flag 45: Battery Module Level 10 C Flag 46: Battery Module Level 10 D Flag 47: Battery Module Level 10 E Flag 48: Battery Module Level 10 F Flag 49: <Not Used> Flag 50: <Not Used> Flag 51: <Not Used> Flag 52: <Not Used> Flag 53: <Not Used> Flag 54: <Not Used> Flag 55: <Not Used> Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used>
1.3.6.1.4.1.318.1.1.1.13.3.4.1.2DisplayStringread-onlymandatory
upsDiagBatteryPositiveVoltage
OBJECT-TYPE
The battery positive voltage, in Volts.
1.3.6.1.4.1.318.1.1.1.13.3.4.1.3INTEGERread-onlymandatory
upsDiagBatteryNegativeVoltage
OBJECT-TYPE
The battery negative voltage, in Volts.
1.3.6.1.4.1.318.1.1.1.13.3.4.1.4INTEGERread-onlymandatory
upsDiagBatteryTemperature
OBJECT-TYPE
The battery frame/cabinet temperature in tenths of degrees celsius. If the frame/cabinet is not present, this variable is set to (-1).
1.3.6.1.4.1.318.1.1.1.13.3.4.1.5INTEGERread-onlymandatory
upsDiagnosticSubsystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.4
upsDiagSubSysFrameTableSize
OBJECT-TYPE
The number of frames attached to the UPS including the Main frame.
1.3.6.1.4.1.318.1.1.1.13.4.1INTEGERread-onlymandatory
upsDiagSubSysFrameTable
OBJECT-TYPE
Allows for diagnostics of individual XR Frames.
1.3.6.1.4.1.318.1.1.1.13.4.2not-accessiblemandatory
upsDiagSubSysFrameEntry
OBJECT-TYPE
The diagnostics of an XR Frame.
1.3.6.1.4.1.318.1.1.1.13.4.2.1not-accessiblemandatory
upsDiagSubSysFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.2.1.1INTEGERread-onlymandatory
upsDiagSubSysFrameType
OBJECT-TYPE
The type of Frame. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. frameTypeMain(3) indicates the frame type is the Main Frame. frameTypeXR(4) indicates the frame type is an XR Frame. frameTypeLXR(5) indicates the frame type is an LXR Frame.
1.3.6.1.4.1.318.1.1.1.13.4.2.1.2INTEGER {unknown(1), notInstalled(2), frameTypeMain(3), frameTypeXR(4), frameTypeLXR(5)}read-onlymandatory
upsDiagSubSysFrameFirmwareRev
OBJECT-TYPE
The firmware revision of the frame.
1.3.6.1.4.1.318.1.1.1.13.4.2.1.3DisplayStringread-onlymandatory
upsDiagSubSysFrameHardwareRev
OBJECT-TYPE
The hardware revision of the frame.
1.3.6.1.4.1.318.1.1.1.13.4.2.1.4DisplayStringread-onlymandatory
upsDiagSubSysFrameSerialNum
OBJECT-TYPE
The serial number of the frame.
1.3.6.1.4.1.318.1.1.1.13.4.2.1.5DisplayStringread-onlymandatory
upsDiagSubSysFrameManufactureDate
OBJECT-TYPE
The manufacture date of the frame.
1.3.6.1.4.1.318.1.1.1.13.4.2.1.6DisplayStringread-onlymandatory
upsDiagSubSysIntBypSwitchTableSize
OBJECT-TYPE
The number of Internal Bypass switches attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.3INTEGERread-onlymandatory
upsDiagSubSysIntBypSwitchTable
OBJECT-TYPE
Allows for diagnostics of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4not-accessiblemandatory
upsDiagSubSysIntBypSwitchEntry
OBJECT-TYPE
The diagnostics of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4.1not-accessiblemandatory
upsDiagSubSysIntBypSwitchFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.1INTEGERread-onlymandatory
upsDiagSubSysIntBypSwitchIndex
OBJECT-TYPE
The Internal Bypass Switch index entry.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.2INTEGERread-onlymandatory
upsDiagSubSysIntBypSwitchStatus
OBJECT-TYPE
The Internal Bypass Switch status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysIntBypSwitchFirmwareRev
OBJECT-TYPE
The firmware revision of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.4DisplayStringread-onlymandatory
upsDiagSubSysIntBypSwitchHardwareRev
OBJECT-TYPE
The hardware revision of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.5DisplayStringread-onlymandatory
upsDiagSubSysIntBypSwitchSerialNum
OBJECT-TYPE
The serial number of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.6DisplayStringread-onlymandatory
upsDiagSubSysIntBypSwitchManufactureDate
OBJECT-TYPE
The manufacture date of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.7DisplayStringread-onlymandatory
upsDiagSubSysIntBypSwitchModelNum
OBJECT-TYPE
The model number of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.4.1.8DisplayStringread-onlymandatory
upsDiagSubSysBattMonitorTableSize
OBJECT-TYPE
The number of Battery Monitor Boards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.5INTEGERread-onlymandatory
upsDiagSubSysBattMonitorTable
OBJECT-TYPE
Allows for diagnostics of the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6not-accessiblemandatory
upsDiagSubSysBattMonitorEntry
OBJECT-TYPE
The diagnostics of the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6.1not-accessiblemandatory
upsDiagSubSysBattMonitorFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.1INTEGERread-onlymandatory
upsDiagSubSysBattMonitorIndex
OBJECT-TYPE
The index of the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.2INTEGERread-onlymandatory
upsDiagSubSysBattMonitorStatus
OBJECT-TYPE
The status of the Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysBattMonitorFirmwareRev
OBJECT-TYPE
The firmware revision of the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.4DisplayStringread-onlymandatory
upsDiagSubSysBattMonitorHardwareRev
OBJECT-TYPE
The hardware revision of the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.5DisplayStringread-onlymandatory
upsDiagSubSysBattMonitorSerialNum
OBJECT-TYPE
The serial number of the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.6DisplayStringread-onlymandatory
upsDiagSubSysBattMonitorManufactureDate
OBJECT-TYPE
The date of the manufacture for the Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.6.1.7DisplayStringread-onlymandatory
upsDiagSubSysExternalSwitchGearTableSize
OBJECT-TYPE
The number of External Switch Gears attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.7INTEGERread-onlymandatory
upsDiagSubSysExternalSwitchGearTable
OBJECT-TYPE
Allows for diagnostics of the individual External Switch Gear.
1.3.6.1.4.1.318.1.1.1.13.4.8not-accessiblemandatory
upsDiagSubSysExternalSwitchGearEntry
OBJECT-TYPE
The diagnostics of an individual External Switch Gear.
1.3.6.1.4.1.318.1.1.1.13.4.8.1not-accessiblemandatory
upsDiagSubSysExternalSwitchGearFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.1INTEGERread-onlymandatory
upsDiagSubSysExternalSwitchGearIndex
OBJECT-TYPE
The index of the External Switch Gear.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.2INTEGERread-onlymandatory
upsDiagSubSysExternalSwitchGearStatus
OBJECT-TYPE
The status of the External Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysExternalSwitchGearFirmwareRev
OBJECT-TYPE
The firmware revision of the External Switch Gear monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.4DisplayStringread-onlymandatory
upsDiagSubSysExternalSwitchGearHardwareRev
OBJECT-TYPE
The hardware revision of the External Switch Gear monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.5DisplayStringread-onlymandatory
upsDiagSubSysExternalSwitchGearSerialNum
OBJECT-TYPE
The serial number of the External Switch Gear monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.6DisplayStringread-onlymandatory
upsDiagSubSysExternalSwitchGearManufactureDate
OBJECT-TYPE
The date of the manufacture for the External Switch Gear monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.7DisplayStringread-onlymandatory
upsDiagSubSysExternalSwitchGearTemperature
OBJECT-TYPE
The temperature of the air around the External Switch Gear monitor card in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.1.13.4.8.1.8INTEGERread-onlymandatory
upsDiagSubSysDisplayInterfaceCardTableSize
OBJECT-TYPE
The number of Display Interface Cards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.9INTEGERread-onlymandatory
upsDiagSubSysDisplayInterfaceCardTable
OBJECT-TYPE
Allows for diagnostics of individual Display Interface Cards.
1.3.6.1.4.1.318.1.1.1.13.4.10not-accessiblemandatory
upsDiagSubSysDisplayInterfaceCardEntry
OBJECT-TYPE
The diagnostics of a Display Interface Card.
1.3.6.1.4.1.318.1.1.1.13.4.10.1not-accessiblemandatory
upsDiagSubSysDisplayInterfaceCardFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.10.1.1INTEGERread-onlymandatory
upsDiagSubSysDisplayInterfaceCardIndex
OBJECT-TYPE
The index of the Display Interface Card.
1.3.6.1.4.1.318.1.1.1.13.4.10.1.2INTEGERread-onlymandatory
upsDiagSubSysDisplayInterfaceCardStatus
OBJECT-TYPE
The status of the Display Interface Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.10.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysDCCircuitBreakerTableSize
OBJECT-TYPE
The number of DC Circuit Breakers attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.11INTEGERread-onlymandatory
upsDiagSubSysDCCircuitBreakerTable
OBJECT-TYPE
Allows for diagnostics of individual DC Circuit Breakers.
1.3.6.1.4.1.318.1.1.1.13.4.12not-accessiblemandatory
upsDiagSubSysDCCircuitBreakerEntry
OBJECT-TYPE
The diagnostics of a DC Circuit Breaker.
1.3.6.1.4.1.318.1.1.1.13.4.12.1not-accessiblemandatory
upsDiagSubSysDCCircuitBreakerFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.12.1.1INTEGERread-onlymandatory
upsDiagSubSysDCCircuitBreakerIndex
OBJECT-TYPE
The index of the DC Circuit Breaker.
1.3.6.1.4.1.318.1.1.1.13.4.12.1.2INTEGERread-onlymandatory
upsDiagSubSysDCCircuitBreakerStatus
OBJECT-TYPE
The status of the DC Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed.
1.3.6.1.4.1.318.1.1.1.13.4.12.1.3INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagSubSysSystemPowerSupplyTableSize
OBJECT-TYPE
The number of System Power Supplies attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.13INTEGERread-onlymandatory
upsDiagSubSysSystemPowerSupplyTable
OBJECT-TYPE
Allows for diagnostics of individual System Power Supplies.
1.3.6.1.4.1.318.1.1.1.13.4.14not-accessiblemandatory
upsDiagSubSysSystemPowerSupplyEntry
OBJECT-TYPE
The diagnostics of a System Power Supply.
1.3.6.1.4.1.318.1.1.1.13.4.14.1not-accessiblemandatory
upsDiagSubSysSystemPowerSupplyFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.1INTEGERread-onlymandatory
upsDiagSubSysSystemPowerSupplyIndex
OBJECT-TYPE
The index of a System Power Supply.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.2INTEGERread-onlymandatory
upsDiagSubSysSystemPowerSupplyStatus
OBJECT-TYPE
The status of the System Power Supply. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysSystemPowerSupplyFirmwareRev
OBJECT-TYPE
The firmware revision of the System Power Supply monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.4DisplayStringread-onlymandatory
upsDiagSubSysSystemPowerSupplyHardwareRev
OBJECT-TYPE
The hardware revision of the System Power Supply monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.5DisplayStringread-onlymandatory
upsDiagSubSysSystemPowerSupplySerialNum
OBJECT-TYPE
The serial number of the System Power Supply monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.6DisplayStringread-onlymandatory
upsDiagSubSysSystemPowerSupplyManufactureDate
OBJECT-TYPE
The date of the manufacture for the System Power Supply monitor card.
1.3.6.1.4.1.318.1.1.1.13.4.14.1.7DisplayStringread-onlymandatory
upsDiagSubSysXRCommunicationCardTableSize
OBJECT-TYPE
The number of XR Communication Cards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.15INTEGERread-onlymandatory
upsDiagSubSysXRCommunicationCardTable
OBJECT-TYPE
Allows for diagnostics of individual XR Communication Cards.
1.3.6.1.4.1.318.1.1.1.13.4.16not-accessiblemandatory
upsDiagSubSysXRCommunicationCardEntry
OBJECT-TYPE
The diagnostics of an XR Communication Card.
1.3.6.1.4.1.318.1.1.1.13.4.16.1not-accessiblemandatory
upsDiagSubSysXRCommunicationCardFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.16.1.1INTEGERread-onlymandatory
upsDiagSubSysXRCommunicationCardIndex
OBJECT-TYPE
The index of an XR Communication Card.
1.3.6.1.4.1.318.1.1.1.13.4.16.1.2INTEGERread-onlymandatory
upsDiagSubSysXRCommunicationCardStatus
OBJECT-TYPE
The status of the XR Communication Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.16.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysXRCommunicationCardFirmwareRev
OBJECT-TYPE
The firmware revision of the XR Communication card.
1.3.6.1.4.1.318.1.1.1.13.4.16.1.4DisplayStringread-onlymandatory
upsDiagSubSysXRCommunicationCardSerialNum
OBJECT-TYPE
The serial number of the XR Communication card.
1.3.6.1.4.1.318.1.1.1.13.4.16.1.5DisplayStringread-onlymandatory
upsDiagSubSysExternalPowerFrameBoardTableSize
OBJECT-TYPE
The number of External Power Frame Boards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.17INTEGERread-onlymandatory
upsDiagSubSysExternalPowerFrameBoardTable
OBJECT-TYPE
Allows for diagnostics of individual External Power Frame Boards.
1.3.6.1.4.1.318.1.1.1.13.4.18not-accessiblemandatory
upsDiagSubSysExternalPowerFrameBoardEntry
OBJECT-TYPE
The diagnostics of an External Power Frame Board.
1.3.6.1.4.1.318.1.1.1.13.4.18.1not-accessiblemandatory
upsDiagSubSysExternalPowerFrameBoardFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.18.1.1INTEGERread-onlymandatory
upsDiagSubSysExternalPowerFrameBoardIndex
OBJECT-TYPE
The index of an External Power Frame Board.
1.3.6.1.4.1.318.1.1.1.13.4.18.1.2INTEGERread-onlymandatory
upsDiagSubSysExternalPowerFrameBoardStatus
OBJECT-TYPE
The status of the External Power Frame Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.18.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysChargerTableSize
OBJECT-TYPE
The number of Chargers attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.19INTEGERread-onlymandatory
upsDiagSubSysChargerTable
OBJECT-TYPE
Allows for diagnostics of individual chargers.
1.3.6.1.4.1.318.1.1.1.13.4.20not-accessiblemandatory
upsDiagSubSysChargerEntry
OBJECT-TYPE
The diagnostics of a charger.
1.3.6.1.4.1.318.1.1.1.13.4.20.1not-accessiblemandatory
upsDiagSubSysChargerFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.20.1.1INTEGERread-onlymandatory
upsDiagSubSysChargerIndex
OBJECT-TYPE
The index of a charger.
1.3.6.1.4.1.318.1.1.1.13.4.20.1.2INTEGERread-onlymandatory
upsDiagSubSysChargerStatus
OBJECT-TYPE
The status of the Charger. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.20.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysInverterTableSize
OBJECT-TYPE
The number of Inverters attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.21INTEGERread-onlymandatory
upsDiagSubSysInverterTable
OBJECT-TYPE
Allows for diagnostics of individual Inverters.
1.3.6.1.4.1.318.1.1.1.13.4.22not-accessiblemandatory
upsDiagSubSysInverterEntry
OBJECT-TYPE
The diagnostics of an Inverter.
1.3.6.1.4.1.318.1.1.1.13.4.22.1not-accessiblemandatory
upsDiagSubSysInverterFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.1INTEGERread-onlymandatory
upsDiagSubSysInverterIndex
OBJECT-TYPE
The index of an Inverter.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.2INTEGERread-onlymandatory
upsDiagSubSysInverterStatus
OBJECT-TYPE
The status of the Inverter. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysInverterFirmwareRev
OBJECT-TYPE
The firmware revision of the Inverter monitor.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.4DisplayStringread-onlymandatory
upsDiagSubSysInverterHardwareRev
OBJECT-TYPE
The hardware revision of the Inverter monitor.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.5DisplayStringread-onlymandatory
upsDiagSubSysInverterSerialNum
OBJECT-TYPE
The serial number of the Inverter monitor.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.6DisplayStringread-onlymandatory
upsDiagSubSysInverterManufactureDate
OBJECT-TYPE
The date of manufacture for the Inverter monitor.
1.3.6.1.4.1.318.1.1.1.13.4.22.1.7DisplayStringread-onlymandatory
upsDiagSubSysPowerFactorCorrectionTableSize
OBJECT-TYPE
The number of Power Factor Correction devices attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.23INTEGERread-onlymandatory
upsDiagSubSysPowerFactorCorrectionTable
OBJECT-TYPE
Allows for diagnostics of individual PowerFactorCorrections.
1.3.6.1.4.1.318.1.1.1.13.4.24not-accessiblemandatory
upsDiagSubSysPowerFactorCorrectionEntry
OBJECT-TYPE
The diagnostics of a Power Factor Correction.
1.3.6.1.4.1.318.1.1.1.13.4.24.1not-accessiblemandatory
upsDiagSubSysPowerFactorCorrectionFrameIndex
OBJECT-TYPE
The frame index entry.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.1INTEGERread-onlymandatory
upsDiagSubSysPowerFactorCorrectionIndex
OBJECT-TYPE
The index of a Power Factor Correction.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.2INTEGERread-onlymandatory
upsDiagSubSysPowerFactorCorrectionStatus
OBJECT-TYPE
The status of the Power Factor Correction. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.3INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysPowerFactorCorrectionFirmwareRev
OBJECT-TYPE
The firmware revision of the Power Factor Correction monitor.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.4DisplayStringread-onlymandatory
upsDiagSubSysPowerFactorCorrectionHardwareRev
OBJECT-TYPE
The hardware revision of the Power Factor Correction monitor.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.5DisplayStringread-onlymandatory
upsDiagSubSysPowerFactorCorrectionSerialNum
OBJECT-TYPE
The serial number of the Power Factor Correction monitor.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.6DisplayStringread-onlymandatory
upsDiagSubSysPowerFactorCorrectionManufactureDate
OBJECT-TYPE
The date of the manufacture for the Power Factor Correction monitor.
1.3.6.1.4.1.318.1.1.1.13.4.24.1.7DisplayStringread-onlymandatory
upsDiagSubSysNetworkComCardTableSize
OBJECT-TYPE
The number of Network Communication Cards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.25INTEGERread-onlymandatory
upsDiagSubSysNetworkComCardTable
OBJECT-TYPE
Allows for getting diagnostics information of an individual Network Communication Card.
1.3.6.1.4.1.318.1.1.1.13.4.26not-accessiblemandatory
upsDiagSubSysNetworkComCardEntry
OBJECT-TYPE
The diagnostics of a Network Communication Card.
1.3.6.1.4.1.318.1.1.1.13.4.26.1not-accessiblemandatory
upsDiagSubSysNetworkComCardIndex
OBJECT-TYPE
The UPS network and display interface communication card index entry.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.1INTEGERread-onlymandatory
upsDiagSubSysNetworkComCardModelNumber
OBJECT-TYPE
A character string identifying the model number of the UPS network and display interface communication card. This value is set at the factory.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.2DisplayStringread-onlymandatory
upsDiagSubSysNetworkComCardSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the UPS network and display interface communication card. This value is set at the factory.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.3DisplayStringread-onlymandatory
upsDiagSubSysNetworkComCardDateOfManufacture
OBJECT-TYPE
The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.4DisplayStringread-onlymandatory
upsDiagSubSysNetworkComCardHardwareRev
OBJECT-TYPE
The hardware revision of the UPS network and display interface communication card. This value is set at the factory.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.5DisplayStringread-onlymandatory
upsDiagSubSysNetworkComCardFirmwareAppRev
OBJECT-TYPE
An ID string identifying the application firmware revision of the UPS network and display interface communication card.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.6DisplayStringread-onlymandatory
upsDiagSubSysNetworkComCardFirmwareAppOSRev
OBJECT-TYPE
An ID string identifying the application operating system firmware revision of the UPS network and display interface communication card.
1.3.6.1.4.1.318.1.1.1.13.4.26.1.7DisplayStringread-onlymandatory
upsDiagSubSysUsrSuppBattMonitorTableSize
OBJECT-TYPE
The number of user supplied Battery Monitor Boards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.27INTEGERread-onlymandatory
upsDiagSubSysUsrSuppBattMonitorTable
OBJECT-TYPE
Allows for diagnostics of the user supplied Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.28not-accessiblemandatory
upsDiagSubSysUsrSuppBattMonitorEntry
OBJECT-TYPE
The diagnostics of the user supplied Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.28.1not-accessiblemandatory
upsDiagSubSysUsrSuppBattMonitorIndex
OBJECT-TYPE
The index of the user supplied Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.28.1.1INTEGERread-onlymandatory
upsDiagSubSysUsrSuppBattMonitorStatus
OBJECT-TYPE
The status of the user supplied Battery Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.28.1.2INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysUsrSuppBattMonitorFirmwareRev
OBJECT-TYPE
The firmware revision of the user supplied Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.28.1.3DisplayStringread-onlymandatory
upsDiagSubSysUsrSuppBattMonitorHardwareRev
OBJECT-TYPE
The hardware revision of the user supplied Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.28.1.4DisplayStringread-onlymandatory
upsDiagSubSysUsrSuppBattMonitorSerialNum
OBJECT-TYPE
The serial number of the user supplied Battery Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.4.28.1.5DisplayStringread-onlymandatory
upsDiagSubSysUsrSuppBattMonitorTemperature
OBJECT-TYPE
The temperature of the air around the user supplied Battery Monitor Board in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.1.13.4.28.1.6INTEGERread-onlymandatory
upsDiagSubSysUsrSuppBattBreakerStatus
OBJECT-TYPE
The status of the user supplied Battery Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed.
1.3.6.1.4.1.318.1.1.1.13.4.29INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagSubSysPSUTableSize
OBJECT-TYPE
The number of Power Supply Units in the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.30INTEGERread-onlymandatory
upsDiagSubSysPSUTable
OBJECT-TYPE
Allows for diagnostics of individual Power Supply Units. The number of entries is contained in the upsDiagSubSysPSUTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.4.31not-accessiblemandatory
upsDiagSubSysPSUEntry
OBJECT-TYPE
The diagnostics information of a Power Supply Unit.
1.3.6.1.4.1.318.1.1.1.13.4.31.1not-accessiblemandatory
upsDiagSubSysPSUIndex
OBJECT-TYPE
The index to the Power Supply Unit entry.
1.3.6.1.4.1.318.1.1.1.13.4.31.1.1INTEGERread-onlymandatory
upsDiagSubSysPSUStatus
OBJECT-TYPE
The status of the Power Supply Unit. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.31.1.2INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysIDRCTableSize
OBJECT-TYPE
The number of ID and Relay Controller Cards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.32INTEGERread-onlymandatory
upsDiagSubSysIDRCTable
OBJECT-TYPE
Allows for diagnostics of the ID and Relay Controller Card.
1.3.6.1.4.1.318.1.1.1.13.4.33not-accessiblemandatory
upsDiagSubSysIDRCEntry
OBJECT-TYPE
The diagnostics of the ID and Relay Controller Card.
1.3.6.1.4.1.318.1.1.1.13.4.33.1not-accessiblemandatory
upsDiagSubSysIDRCIndex
OBJECT-TYPE
The index of the ID and Relay Controller Card.
1.3.6.1.4.1.318.1.1.1.13.4.33.1.1INTEGERread-onlymandatory
upsDiagSubSysIDRCStatus
OBJECT-TYPE
The status of the ID and Relay Controller Card. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.33.1.2INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysIDRCFirmwareRev
OBJECT-TYPE
The firmware revision of the ID and Relay Controller Card.
1.3.6.1.4.1.318.1.1.1.13.4.33.1.3DisplayStringread-onlymandatory
upsDiagSubSysIDRCHardwareRev
OBJECT-TYPE
The hardware revision of the ID and Relay Controller Card.
1.3.6.1.4.1.318.1.1.1.13.4.33.1.4DisplayStringread-onlymandatory
upsDiagSubSysIDRCSerialNum
OBJECT-TYPE
The serial number of the ID and Relay Controller Card.
1.3.6.1.4.1.318.1.1.1.13.4.33.1.5DisplayStringread-onlymandatory
upsDiagSubSysExternalConnectorStatus
OBJECT-TYPE
The status of the external connector board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.4.34INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagSubSysBackfeedContactorTableSize
OBJECT-TYPE
The number of backfeed protection contactor attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.35INTEGERread-onlymandatory
upsDiagSubSysBackfeedContactorTable
OBJECT-TYPE
Backfeed protection contactor table.
1.3.6.1.4.1.318.1.1.1.13.4.36not-accessiblemandatory
upsDiagSubSysBackfeedContactorEntry
OBJECT-TYPE
A list of backfeed protection contactors.
1.3.6.1.4.1.318.1.1.1.13.4.36.1not-accessiblemandatory
upsDiagSubSysbackfeedContactorIndex
OBJECT-TYPE
The index of the backfeed protection contactor.
1.3.6.1.4.1.318.1.1.1.13.4.36.1.1INTEGERread-onlymandatory
upsDiagSubSysbackfeedContactorName
OBJECT-TYPE
The name of the backfeed protection contactor.
1.3.6.1.4.1.318.1.1.1.13.4.36.1.2DisplayStringread-writemandatory
upsDiagSubSysbackfeedContactorType
OBJECT-TYPE
Indicates the backfeed protection contactor types available in the UPS system. If the UPS is unable to find any attached contactors, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.13.4.36.1.3INTEGER {unknown(1), normalAC(2), bypassAC(3)}read-onlymandatory
upsDiagSubSysbackfeedContactorStatus
OBJECT-TYPE
The status of backfeed protection contactor. unknown(1) indicates the contactor status is unknown. opened (2) indicates the contactor is opened. closed (3) indicates the contactor is closed.
1.3.6.1.4.1.318.1.1.1.13.4.36.1.4INTEGER {unknown(1), opened(2), closed(3)}read-onlymandatory
upsDiagSubSysIntBypSwitchFanLifetimeInfoTableSize
OBJECT-TYPE
The number of backfeed protection contactor attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.4.37INTEGERread-onlymandatory
upsDiagSubSysIntBypSwitchFanLifetimeInfoTable
OBJECT-TYPE
Allows for diagnostics of the Internal Bypass Switch life time infomation.
1.3.6.1.4.1.318.1.1.1.13.4.38not-accessiblemandatory
upsDiagSubSysIntBypSwitchFanLifetimeInfoEntry
OBJECT-TYPE
The diagnostics of the Internal Bypass Switch.
1.3.6.1.4.1.318.1.1.1.13.4.38.1not-accessiblemandatory
upsDiagSubSysIntBypSwitchFanLifetimeInfoIndex
OBJECT-TYPE
The index to the Internal Bypass Switch Fan liftime information entry
1.3.6.1.4.1.318.1.1.1.13.4.38.1.1INTEGERread-onlymandatory
upsDiagSubSysIntBypSwitchFanLifetimeStatus
OBJECT-TYPE
The status of the Internal Bypass Switch Fan lifetime information. ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceeded. unknown(4) indicates the device lifetime status is unknown.
1.3.6.1.4.1.318.1.1.1.13.4.38.1.2INTEGER {ok(1), nearEnd(2), exceeded(3), unknown(4)}read-onlymandatory
upsDiagSubSysIntBypSwitchFanEstmtdLifetimeRmng
OBJECT-TYPE
Displays the time remaining for the module before it should be replaced. Measured in months. This value is set when you originally install the module.
1.3.6.1.4.1.318.1.1.1.13.4.38.1.3INTEGERread-onlymandatory
upsDiagSubSysIntBypSwitchFanEstmtdLifetimeRmngPct
OBJECT-TYPE
Displays the percentage of the total lifetime remaining for the module before it should be replaced.
1.3.6.1.4.1.318.1.1.1.13.4.38.1.4INTEGERread-onlymandatory
upsDiagnosticExternalDevices
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.5
upsDiagSwitchGear
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.5.1
upsDiagSwitchGearStatus
OBJECT-TYPE
The status of the Switch Gear. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. fail(4) indicates the device status has failed. lostComm(5) indicates the device has lost communication. overtemp(6) indicates the device has an over temperature condition.
1.3.6.1.4.1.318.1.1.1.13.5.1.1INTEGER {unknown(1), notInstalled(2), ok(3), fail(4), lostComm(5), overtemp(6)}read-onlymandatory
upsDiagSwitchGearInputSwitchStatus
OBJECT-TYPE
The status of the Switch Gear Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
1.3.6.1.4.1.318.1.1.1.13.5.1.2INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagSwitchGearOutputSwitchStatus
OBJECT-TYPE
The status of the Switch Gear Output Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
1.3.6.1.4.1.318.1.1.1.13.5.1.3INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagSwitchGearBypassSwitchStatus
OBJECT-TYPE
The status of the Switch Gear Bypass Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
1.3.6.1.4.1.318.1.1.1.13.5.1.4INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagSwitchGearBypassInputSwitchStatus
OBJECT-TYPE
The status of the Switch Gear Bypass Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
1.3.6.1.4.1.318.1.1.1.13.5.1.5INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagSwitchGearBreakerTableSize
OBJECT-TYPE
The number of switchgear breakers attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.5.1.6INTEGERread-onlymandatory
upsDiagSwitchGearBreakerTable
OBJECT-TYPE
Switchgear breaker table.
1.3.6.1.4.1.318.1.1.1.13.5.1.7not-accessiblemandatory
upsDiagSwitchGearBreakerEntry
OBJECT-TYPE
A list of switchgear breakers.
1.3.6.1.4.1.318.1.1.1.13.5.1.7.1not-accessiblemandatory
switchgearBreakerIndex
OBJECT-TYPE
The index of the switchgear breaker.
1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.1INTEGERread-onlymandatory
switchgearBreakerPresent
OBJECT-TYPE
Indicates if the switchgear breaker is present. notPresent(1) indicates that the breaker is not present. present(2) indicates that the breaker is present.
1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.2INTEGER {notPresent(1), present(2)}read-onlymandatory
switchgearBreakerName
OBJECT-TYPE
The name of the switchgear breaker.
1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.3DisplayStringread-writemandatory
switchgearBreakerType
OBJECT-TYPE
Indicates the switchgear breaker types available in the UPS system. If the UPS is unable to find any attached breakers, this variable is set to unknown(1). If the system has multiple breakers of the same type (eg. multiple battery breakers) the status shown in OID switchgearBreakerStatus will be the aggregated status.
1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.4INTEGER {unknown(1), unitInputBreaker(2), staticSwitchInputBreaker(3), maintenanceBypassBreaker(4), unitOutputBreaker(5), systemIsolationBreaker(6), batteryBreaker(7), bypassBackFeedBreaker(8), internalMaintenanceBypassBreaker(9), redundantInternalMaintenanceBypassBreaker(10)}read-onlymandatory
switchgearBreakerStatus
OBJECT-TYPE
The status of switchgear breaker. unknown(1) indicates the breaker status is unknown. opened (2) indicates the breaker is opened. closed (3) indicates the breaker is closed. NOTE: If there are more than one breaker of the same type, the status reflects the aggregated value. For battery breakers as example, closed would mean that at least one breaker is closed.
1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.5INTEGER {unknown(1), opened(2), closed(3)}read-onlymandatory
upsDiagSubFeedBreakerTableSize
OBJECT-TYPE
The number of subfeed breakers attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.5.1.8INTEGERread-onlymandatory
upsDiagSubFeedBreakerTable
OBJECT-TYPE
Subfeed breaker table.
1.3.6.1.4.1.318.1.1.1.13.5.1.9not-accessiblemandatory
upsDiagSubFeedBreakerEntry
OBJECT-TYPE
A list of subfeed breakers.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1not-accessiblemandatory
subfeedBreakerIndex
OBJECT-TYPE
The index of the subfeed breakers.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.1INTEGERread-onlymandatory
subfeedBreakerPresent
OBJECT-TYPE
Indicates if the subfeed breaker is present. notPresent (1) indicates that the breaker is not present. present (2) indicates that the breaker is present.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.2INTEGER {notPresent(1), present(2)}read-onlymandatory
subfeedBreakerRating
OBJECT-TYPE
The current rating of the installed subfeed breaker.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.3INTEGERread-onlymandatory
subfeedBreakerUpperAcceptPowerWarning
OBJECT-TYPE
The maximum acceptable load before warning is issued. Expressed as percent of the subfeed breaker rating.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.4INTEGER (0..100)read-writemandatory
subfeedBreakerUpperAcceptPowerCritical
OBJECT-TYPE
The maximum load before a critical alarm occurs. Expressed as percent of the subfeed breaker rating.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.5INTEGER (0..125)read-writemandatory
subfeedBreakerStatus
OBJECT-TYPE
The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.6INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
subfeedBreakerName
OBJECT-TYPE
The name of the subfeed breaker.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.7DisplayStringread-writemandatory
subfeedBreakerCurrent
OBJECT-TYPE
The subfeed current in tenths of Amps.
1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.8INTEGERread-onlymandatory
upsDiagSwitchGearInstallationLoadPct
OBJECT-TYPE
The actual output load expressed as a percentage of the rating of the UPS.
1.3.6.1.4.1.318.1.1.1.13.5.1.10INTEGERread-onlymandatory
upsDiagSubFeedPhaseTable
OBJECT-TYPE
A list of subfeed phase table.
1.3.6.1.4.1.318.1.1.1.13.5.1.11not-accessiblemandatory
upsDiagSubFeedPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular phase.
1.3.6.1.4.1.318.1.1.1.13.5.1.11.1not-accessiblemandatory
upsDiagSubFeedBreakerIndex
OBJECT-TYPE
The subfeed breaker index.
1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.1INTEGERread-onlymandatory
upsDiagSubFeedPhaseIndex
OBJECT-TYPE
The subfeed phase index.
1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.2INTEGERread-onlymandatory
upsDiagSubFeedPhaseCurrent
OBJECT-TYPE
The subfeed phase current in Amps.
1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.3INTEGERread-onlymandatory
upsDiagSubFeedPhaseCurrentAlternate
OBJECT-TYPE
The subfeed phase current in tenths of Amps.
1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.4INTEGERread-onlymandatory
upsDiagSwitchgearSerialNumber
OBJECT-TYPE
The serial number of the UPS I/O Cabinet.
1.3.6.1.4.1.318.1.1.1.13.5.1.12DisplayStringread-onlymandatory
upsDiagSwitchgearAmbientTemperature
OBJECT-TYPE
The ambient temperature of I/O Cabinet in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.1.13.5.1.13INTEGERread-onlymandatory
upsDiagUsrSuppSwitchgearMonitorTableSize
OBJECT-TYPE
The number of user supplied Switch Gear Monitor Boards attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.5.1.14INTEGERread-onlymandatory
upsDiagUsrSuppSwitchgearMonitorTable
OBJECT-TYPE
Allows for diagnostics of the user supplied Switch Gear Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.5.1.15not-accessiblemandatory
upsDiagUsrSuppSwitchgearMonitorEntry
OBJECT-TYPE
The diagnostics of the user supplied Switch Gear Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1not-accessiblemandatory
upsDiagUsrSuppSwitchgearMonitorIndex
OBJECT-TYPE
The index of the user supplied Switch Gear Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.1INTEGERread-onlymandatory
upsDiagUsrSuppSwitchgearMonitorStatus
OBJECT-TYPE
The status of the user supplied Switch Gear Monitor Board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.2INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagUsrSuppSwitchgearMonitorFirmwareRev
OBJECT-TYPE
The firmware revision of the user supplied Switch Gear Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.3DisplayStringread-onlymandatory
upsDiagUsrSuppSwitchgearMonitorHardwareRev
OBJECT-TYPE
The hardware revision of the user supplied Switch Gear Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.4DisplayStringread-onlymandatory
upsDiagUsrSuppSwitchgearMonitorSerialNum
OBJECT-TYPE
The serial number of the user supplied Switch Gear Monitor Board.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.5DisplayStringread-onlymandatory
upsDiagUsrSuppSwitchgearMonitorTemperature
OBJECT-TYPE
The temperature of the air around the user supplied Switch Gear Monitor Board in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.6INTEGERread-onlymandatory
upsDiagMCCBBox
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.5.2
upsDiagMCCBBoxStatus
OBJECT-TYPE
The status of the MCCB Box (Molded Case Circuit Breaker Box) external device. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. opened(3) indicates the circuit is opened. closed(4) indicates the circuit is closed.
1.3.6.1.4.1.318.1.1.1.13.5.2.1INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsDiagTransformer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.5.3
upsDiagTransformerStatus
OBJECT-TYPE
The status of the External Transformer. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. fail(4) indicates the device status has failed. lostComm(5) indicates the device has lost communication. overtemp(6) indicates the device has an over temperature condition. opened(7) indicates the circuit is opened. closed(8) indicates the circuit is closed.
1.3.6.1.4.1.318.1.1.1.13.5.3.1INTEGER {unknown(1), notInstalled(2), ok(3), fail(4), lostComm(5), overtemp(6), opened(7), closed(8)}read-onlymandatory
upsDiagFlyWheel
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.5.4
upsDiagFlyWheelStatus
OBJECT-TYPE
Indicates the status of flywheel connected to UPS. If the UPS is unable to determine the state of flywheel, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.13.5.4.1INTEGER {unknown(1), present(2), notPresent(3)}read-onlymandatory
upsDiagnosticComBus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.6
upsDiagComBusInternalMIMStatus
OBJECT-TYPE
The status of the internal MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
1.3.6.1.4.1.318.1.1.1.13.6.1INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)}read-onlymandatory
upsDiagComBusInternalRIMStatus
OBJECT-TYPE
The status of the internal RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
1.3.6.1.4.1.318.1.1.1.13.6.2INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)}read-onlymandatory
upsDiagComBusMIMtoRIMStatus
OBJECT-TYPE
The status of the MIM to RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
1.3.6.1.4.1.318.1.1.1.13.6.3INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)}read-onlymandatory
upsDiagComBusExternalMIMStatus
OBJECT-TYPE
The status of the external MIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
1.3.6.1.4.1.318.1.1.1.13.6.4INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)}read-onlymandatory
upsDiagComBusExternalRIMStatus
OBJECT-TYPE
The status of the external RIM communication bus. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the device status is OK. lostComm(4) indicates the device has lost communication. rxFailure(5) indicates the device has a receive failure. txFailure(6) indicates the device has a transmit failure.
1.3.6.1.4.1.318.1.1.1.13.6.5INTEGER {unknown(1), notInstalled(2), ok(3), lostComm(4), rxFailure(5), txFailure(6)}read-onlymandatory
upsDiagnosticPowerCabinet
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.7
upsDiagnosticPowerCabinetTableSize
OBJECT-TYPE
The maximum number of Power Cabinets supported by the UPS.
1.3.6.1.4.1.318.1.1.1.13.7.1INTEGERread-onlymandatory
upsDiagnosticPowerCabinetTable
OBJECT-TYPE
Allows for diagnostics of individual Power Cabinets. The number of entries is contained in the upsDiagnosticPowerCabinetTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.7.2not-accessiblemandatory
upsDiagnosticPowerCabinetEntry
OBJECT-TYPE
The diagnostics of a Power Cabinet.
1.3.6.1.4.1.318.1.1.1.13.7.2.1not-accessiblemandatory
upsDiagnosticPowerCabinetIndex
OBJECT-TYPE
The index to the Power Cabinet.
1.3.6.1.4.1.318.1.1.1.13.7.2.1.1INTEGERread-onlymandatory
upsDiagnosticPowerCabinetAmbientTemperature
OBJECT-TYPE
The ambient temperature of Power Cabinet in tenths of degrees Celsius. If the Power Cabinet is not present, this variable is set to (-1).
1.3.6.1.4.1.318.1.1.1.13.7.2.1.2INTEGERread-onlymandatory
upsDiagnosticDisplay
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.8
upsDiagnosticDisplayHardwareRev
OBJECT-TYPE
The hardware revision of the Display.
1.3.6.1.4.1.318.1.1.1.13.8.1DisplayStringread-onlymandatory
upsDiagnosticDisplaySerialNum
OBJECT-TYPE
The serial number of the Display.
1.3.6.1.4.1.318.1.1.1.13.8.2DisplayStringread-onlymandatory
upsDiagnosticDisplayFirmwareRev
OBJECT-TYPE
The firmware revision of the Display.
1.3.6.1.4.1.318.1.1.1.13.8.3DisplayStringread-onlymandatory
upsDiagnosticDisplayModelNum
OBJECT-TYPE
The model number of the Display.
1.3.6.1.4.1.318.1.1.1.13.8.4DisplayStringread-onlymandatory
upsDiagnosticDisplayStatus
OBJECT-TYPE
The System Level Controller Status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.8.5INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagnosticUnitController
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.9
upsDiagUnitControllerTableSize
OBJECT-TYPE
The number of Unit Controllers in or attached to the UPS.
1.3.6.1.4.1.318.1.1.1.13.9.1INTEGERread-onlymandatory
upsDiagUnitControllerTable
OBJECT-TYPE
Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagUnitControllerTableSize OID.
1.3.6.1.4.1.318.1.1.1.13.9.2not-accessiblemandatory
upsDiagUnitControllerEntry
OBJECT-TYPE
The diagnostics and information of an Intelligence Module.
1.3.6.1.4.1.318.1.1.1.13.9.2.1not-accessiblemandatory
upsDiagUnitControllerIndex
OBJECT-TYPE
The index to the Unit Controller entry.
1.3.6.1.4.1.318.1.1.1.13.9.2.1.1INTEGERread-onlymandatory
upsDiagUnitControllerStatus
OBJECT-TYPE
The status of the Unit Controller. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.9.2.1.2INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagUnitControllerFirmwareRev
OBJECT-TYPE
The firmware revision of the Unit Controller.
1.3.6.1.4.1.318.1.1.1.13.9.2.1.3DisplayStringread-onlymandatory
upsDiagUnitControllerHardwareRev
OBJECT-TYPE
The hardware revision of the Unit Controller.
1.3.6.1.4.1.318.1.1.1.13.9.2.1.4DisplayStringread-onlymandatory
upsDiagUnitControllerSerialNum
OBJECT-TYPE
The serial number of the Unit Controller.
1.3.6.1.4.1.318.1.1.1.13.9.2.1.5DisplayStringread-onlymandatory
upsDiagUnitControllerModelNum
OBJECT-TYPE
The model number of the Unit Controller.
1.3.6.1.4.1.318.1.1.1.13.9.2.1.6DisplayStringread-onlymandatory
upsDiagnosticSLC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.10
upsDiagnosticSLCHardwareRev
OBJECT-TYPE
The hardware revision of the System Level Controller.
1.3.6.1.4.1.318.1.1.1.13.10.1DisplayStringread-onlymandatory
upsDiagnosticSLCSerialNum
OBJECT-TYPE
The serial number of the System Level Controller.
1.3.6.1.4.1.318.1.1.1.13.10.2DisplayStringread-onlymandatory
upsDiagnosticSLCFirmwareRev
OBJECT-TYPE
The firmware revision of the System Level Controller.
1.3.6.1.4.1.318.1.1.1.13.10.3DisplayStringread-onlymandatory
upsDiagnosticSLCModelNumber
OBJECT-TYPE
The Model number of the System Level Controller.
1.3.6.1.4.1.318.1.1.1.13.10.4DisplayStringread-onlymandatory
upsDiagSLCStatus
OBJECT-TYPE
The System Level Controller Status. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
1.3.6.1.4.1.318.1.1.1.13.10.5INTEGER {unknown(1), notInstalled(2), offOk(3), onOk(4), offFail(5), onFail(6), lostComm(7)}read-onlymandatory
upsDiagnosticTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.13.11
upsDiagnosticTemperatureAmbientTemperature
OBJECT-TYPE
The ambient temperature in tenths of degrees Celsius. If not available, this variable is set to (-1999).
1.3.6.1.4.1.318.1.1.1.13.11.1INTEGERread-onlymandatory
upsParallelSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.14
upsParallelSysLocalAddress
OBJECT-TYPE
Defines the UPS ID number in the parallel system.
1.3.6.1.4.1.318.1.1.1.14.1INTEGERread-writemandatory
upsParallelSysRemoteAddress
OBJECT-TYPE
Defines the total number of UPSs in parallel.
1.3.6.1.4.1.318.1.1.1.14.2INTEGERread-writemandatory
upsParallelSysRedundancy
OBJECT-TYPE
The redundancy warning level for paralleled UPS nplus0 (1) indicates that there are no redundant units. nplus1 (2) indicates that there is one redundant unit. nplus2 (3) indicates that there are two redundant units. nplus3 (4) indicates that there are three redundant units. nplus4 (5) indicates that there are four redundant unit. nplus5 (6) indicates that there are five redundant units.
1.3.6.1.4.1.318.1.1.1.14.3INTEGER {nplus0(1), nplus1(2), nplus2(3), nplus3(4), nplus4(5), nplus5(6)}read-writemandatory
upsParallelInputMaximumCurrent
OBJECT-TYPE
Maximum input RMS current of the parallel system measured in Amperes.
1.3.6.1.4.1.318.1.1.1.14.4INTEGERread-onlymandatory
upsParallelTotalOutputPower
OBJECT-TYPE
The Total Output power of UPS in kW when UPS are configured in parallel or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.5INTEGERread-onlymandatory
upsParallelTotalOutputApparentPower
OBJECT-TYPE
The Total Output Apparent power of UPS in kVA when UPS are configured in parallel or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.6INTEGERread-onlymandatory
upsParallelInputPhaseTable
OBJECT-TYPE
A list of input table entries.
1.3.6.1.4.1.318.1.1.1.14.7not-accessiblemandatory
upsParallelInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase.
1.3.6.1.4.1.318.1.1.1.14.7.1not-accessiblemandatory
upsParallelInputPhaseTableIndex
OBJECT-TYPE
The parallel unit identifier.
1.3.6.1.4.1.318.1.1.1.14.7.1.1INTEGERread-onlymandatory
upsParallelInputPhaseIndex
OBJECT-TYPE
The input phase identifier.
1.3.6.1.4.1.318.1.1.1.14.7.1.2INTEGERread-onlymandatory
upsParallelInputCurrent
OBJECT-TYPE
The input current in amperes, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.7.1.3INTEGERread-onlymandatory
upsParallelInputActivePower
OBJECT-TYPE
The input power in kW, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.7.1.4INTEGERread-onlymandatory
upsParallelInputApparentPower
OBJECT-TYPE
The input apparent power in kVA, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.7.1.5INTEGERread-onlymandatory
upsParallelInputVoltage
OBJECT-TYPE
The input voltage of UPS in volts, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.7.1.6INTEGERread-onlymandatory
upsParallelInputMaxVoltage
OBJECT-TYPE
The peak input voltage in VAC measured since the last reset, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.7.1.7INTEGERread-onlymandatory
upsParallelInputMaxCurrent
OBJECT-TYPE
The peak input current in amperes measured since last reset, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.7.1.8INTEGERread-onlymandatory
upsParallelInputTotalActivePower
OBJECT-TYPE
Total active input power of the parallel system in kW.
1.3.6.1.4.1.318.1.1.1.14.7.1.9INTEGERread-onlymandatory
upsParallelInputTotalApparentPower
OBJECT-TYPE
Total apparent input power of the parallel system in kVA.
1.3.6.1.4.1.318.1.1.1.14.7.1.10INTEGERread-onlymandatory
upsParallelOutputPhaseTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases.
1.3.6.1.4.1.318.1.1.1.14.8not-accessiblemandatory
upsParallelOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular output phase.
1.3.6.1.4.1.318.1.1.1.14.8.1not-accessiblemandatory
upsParallelOutputPhaseTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.1.14.8.1.1INTEGERread-onlymandatory
upsParallelOutputPhaseIndex
OBJECT-TYPE
The output phase identifier.
1.3.6.1.4.1.318.1.1.1.14.8.1.2INTEGERread-onlymandatory
upsParallelOutputCurrent
OBJECT-TYPE
The output current in amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.8.1.3INTEGERread-onlymandatory
upsParallelOutputLoad
OBJECT-TYPE
The output load in VA, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.8.1.4INTEGERread-onlymandatory
upsParallelOutputPercentLoad
OBJECT-TYPE
The percentage of the UPS load capacity in VA at present redundancy being used on this output phase, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.8.1.5INTEGERread-onlymandatory
upsParallelOutputPower
OBJECT-TYPE
The output power in Watts, or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.8.1.6INTEGERread-onlymandatory
upsParallelOutputApparentPowerTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the value of upsOutputNumPhases.
1.3.6.1.4.1.318.1.1.1.14.9not-accessiblemandatory
upsParallelOutputApparentPowerEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.1.14.9.1not-accessiblemandatory
upsParallelOutputApparentPowerTableIndex
OBJECT-TYPE
The UPS parallel output identifier.
1.3.6.1.4.1.318.1.1.1.14.9.1.1INTEGERread-onlymandatory
upsParallelOutputApparentPower
OBJECT-TYPE
The apparent power of each of UPS in kVA when UPS are configured in parallel.
1.3.6.1.4.1.318.1.1.1.14.9.1.2INTEGERread-onlymandatory
upsParallelDiagSubSysBreakerTable
OBJECT-TYPE
Allows for diagnostics of parallel Circuit Breakers.
1.3.6.1.4.1.318.1.1.1.14.10not-accessiblemandatory
upsParallelDiagSubSysBreakerEntry
OBJECT-TYPE
The diagnostics of Circuit Breaker.
1.3.6.1.4.1.318.1.1.1.14.10.1not-accessiblemandatory
upsParallelDiagSubSysBreakerFrameIndex
OBJECT-TYPE
The Parallel UPS index entry.
1.3.6.1.4.1.318.1.1.1.14.10.1.1INTEGERread-onlymandatory
upsParallelDiagSubSysBreakerIndex
OBJECT-TYPE
The index of the Circuit Breaker.
1.3.6.1.4.1.318.1.1.1.14.10.1.2INTEGERread-onlymandatory
upsParallelDiagSubSysBreakerStatus
OBJECT-TYPE
The status of the Circuit Breaker. unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4) indicates the circuit breaker is closed.
1.3.6.1.4.1.318.1.1.1.14.10.1.3INTEGER {unknown(1), notInstalled(2), opened(3), closed(4)}read-onlymandatory
upsParallelDiagSubSysBreakerName
OBJECT-TYPE
The name of Circuit Breaker.
1.3.6.1.4.1.318.1.1.1.14.10.1.4DisplayStringread-onlymandatory
upsParallelOutputTotalPercentLoad
OBJECT-TYPE
The percentage of the UPS total load capacity in kVA or -1 if it's unsupported by this UPS.
1.3.6.1.4.1.318.1.1.1.14.11INTEGERread-onlymandatory
upsParallelOutputActivePowerTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress.
1.3.6.1.4.1.318.1.1.1.14.12not-accessiblemandatory
upsParallelOutputActivePowerEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.1.14.12.1not-accessiblemandatory
upsParallelOutputActivePowerTableIndex
OBJECT-TYPE
The UPS parallel output identifier.
1.3.6.1.4.1.318.1.1.1.14.12.1.1INTEGERread-onlymandatory
upsParallelOutputActivePower
OBJECT-TYPE
The active power of each UPS in kW when UPSs are configured in parallel.
1.3.6.1.4.1.318.1.1.1.14.12.1.2INTEGERread-onlymandatory
upsParallelSysSwitchGearInstallationLoadPct
OBJECT-TYPE
The actual output load expressed as a percentage of the rating of the Parallel UPS system.
1.3.6.1.4.1.318.1.1.1.14.13INTEGERread-onlymandatory
upsParallelSysRedundancyStatus
OBJECT-TYPE
Displays the number of backup or redundant UPSs set up on the parallel system. nplus0 (1) no redundant units. nplus1 (2) one redundant unit. nplus2 (3) two redundant units. nplus3 (4) three redundant units. nplus4 (5) four redundant units. nplus5 (6) five redundant units.
1.3.6.1.4.1.318.1.1.1.14.14INTEGER {nplus0(1), nplus1(2), nplus2(3), nplus3(4), nplus4(5), nplus5(6)}read-onlymandatory
upsParallelSysName
OBJECT-TYPE
An ID string for the group of UPS units in the same parallel system. Some products do not allow write operations for this OID.
1.3.6.1.4.1.318.1.1.1.14.15DisplayStringread-writemandatory
upsParallelSysUpsTableSize
OBJECT-TYPE
The number of UPSs in parallel.
1.3.6.1.4.1.318.1.1.1.14.16INTEGERread-onlymandatory
upsParallelSysUpsTable
OBJECT-TYPE
A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize.
1.3.6.1.4.1.318.1.1.1.14.17not-accessiblemandatory
upsParallelSysUpsEntry
OBJECT-TYPE
An entry containing information applicable to a particular UPS in parallel.
1.3.6.1.4.1.318.1.1.1.14.17.1not-accessiblemandatory
upsParallelSysUpsIndex
OBJECT-TYPE
The index to the Parallel System UPS table entry.
1.3.6.1.4.1.318.1.1.1.14.17.1.1INTEGERread-onlymandatory
upsParallelSysUpsName
OBJECT-TYPE
The UPS id as assigned by the system.
1.3.6.1.4.1.318.1.1.1.14.17.1.2DisplayStringread-onlymandatory
upsParallelSysUpsAlarmStatus
OBJECT-TYPE
The alarm status of the UPS. unknown(1) indicates the UPS status is unknown. normal(2) indicates UPS is functioning normally. informational(3) indicates informational alarm present in the UPS. warning(4) indicates warning alarm present in the UPS. critical(5) indicates critical alarm present in the UPS.
1.3.6.1.4.1.318.1.1.1.14.17.1.3INTEGER {unknown(1), normal(2), informational(3), warning(4), critical(5)}read-onlymandatory
upsParallelSysUpsMode
OBJECT-TYPE
The current operating mode of the UPS. If the UPS is unable to determine the state of the UPS, this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.1.14.17.1.4INTEGER {unknown(1), onLine(2), onBattery(3), onBatteryTest(4), requestedStaticBypass(5), forcedBypass(6), maintenanceBypass(7), off(8), ecoMode(9), hotStandby(10), inquiring(11)}read-onlymandatory
upsParallelSysUpsSerialNumber
OBJECT-TYPE
The Serial number of the UPS in parallel. Equivalent to OID 1.3.6.1.4.1.318.1.1.1.1.2.3 (upsAdvIdentSerialNumber).
1.3.6.1.4.1.318.1.1.1.14.17.1.5DisplayStringread-onlymandatory
upsParallelNumOfUpsPoweringLoad
OBJECT-TYPE
Number of UPS powered and protecting the load which are not defective (no battery fault, no internal fault).
1.3.6.1.4.1.318.1.1.1.14.18INTEGERread-onlymandatory
upsParallelMinNumOfRequiredUps
OBJECT-TYPE
Minimal number of UPS required to guarantee the availability of power.
1.3.6.1.4.1.318.1.1.1.14.19INTEGERread-onlymandatory
upsPhysicalLayout
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.15
upsIOFrameLayoutPositionID
OBJECT-TYPE
Defines the position ID of UPS frame.
1.3.6.1.4.1.318.1.1.1.15.1INTEGERread-onlymandatory
upsBottomFeedFrameLayoutPositionID
OBJECT-TYPE
Defines the position ID of bottom feed frame.
1.3.6.1.4.1.318.1.1.1.15.2INTEGERread-onlymandatory
upsSwitchGearLayoutPositionID
OBJECT-TYPE
Defines the position ID of switchgear.
1.3.6.1.4.1.318.1.1.1.15.3INTEGERread-onlymandatory
upsBatteryFrameLayoutTableSize
OBJECT-TYPE
The number of battery frames.
1.3.6.1.4.1.318.1.1.1.15.4INTEGERread-onlymandatory
upsBatteryFrameLayoutTable
OBJECT-TYPE
Battery frame layout position ID table.
1.3.6.1.4.1.318.1.1.1.15.5not-accessiblemandatory
upsBatteryFrameLayoutEntry
OBJECT-TYPE
A list of layout position IDs of battery frames.
1.3.6.1.4.1.318.1.1.1.15.5.1not-accessiblemandatory
batteryFrameIndex
OBJECT-TYPE
The index of the battery frame.
1.3.6.1.4.1.318.1.1.1.15.5.1.1INTEGERread-onlymandatory
batteryFramePositionID
OBJECT-TYPE
Defines the position ID of each of the battery frames in the row.
1.3.6.1.4.1.318.1.1.1.15.5.1.2INTEGERread-onlymandatory
upsSideCarFrameLayoutTableSize
OBJECT-TYPE
The number of sidecar frames.
1.3.6.1.4.1.318.1.1.1.15.6INTEGERread-onlymandatory
upsSideCarFrameLayoutTable
OBJECT-TYPE
Sidecar frame layout position ID table.
1.3.6.1.4.1.318.1.1.1.15.7not-accessiblemandatory
upsSideCarFrameLayoutEntry
OBJECT-TYPE
A list of sidecar frame layout position IDs.
1.3.6.1.4.1.318.1.1.1.15.7.1not-accessiblemandatory
sideCarFrameIndex
OBJECT-TYPE
The index of the sidecar frame.
1.3.6.1.4.1.318.1.1.1.15.7.1.1INTEGERread-onlymandatory
sideCarFramePositionID
OBJECT-TYPE
Defines the position ID of each of the sidecar frames in the row.
1.3.6.1.4.1.318.1.1.1.15.7.1.2INTEGERread-onlymandatory
upsPowerFrameLayoutTableSize
OBJECT-TYPE
The number of power frames.
1.3.6.1.4.1.318.1.1.1.15.8INTEGERread-onlymandatory
upsPowerFrameLayoutTable
OBJECT-TYPE
Power frame layout position ID table.
1.3.6.1.4.1.318.1.1.1.15.9not-accessiblemandatory
upsPowerFrameLayoutEntry
OBJECT-TYPE
A list of power frame layout position IDs.
1.3.6.1.4.1.318.1.1.1.15.9.1not-accessiblemandatory
powerFrameIndex
OBJECT-TYPE
The index of the power frame.
1.3.6.1.4.1.318.1.1.1.15.9.1.1INTEGERread-onlymandatory
powerFramePositionID
OBJECT-TYPE
Defines the position ID of each of the power frames in the row.
1.3.6.1.4.1.318.1.1.1.15.9.1.2INTEGERread-onlymandatory
upsIntegratedATS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.16
upsIntegratedATSSelectedSource
OBJECT-TYPE
The source which is currently selected by the ATS to supply the UPS.
1.3.6.1.4.1.318.1.1.1.16.1INTEGER {noSourceSelected(1), unknown(2), sourceA(3), sourceB(4)}read-onlymandatory
upsIntegratedATSPreferredSource
OBJECT-TYPE
The preferred source of power when both sources are OK.
1.3.6.1.4.1.318.1.1.1.16.2INTEGER {upsIntegratedATSNoSourcePreference(1), upsIntegratedATSPreferSourceA(2), upsIntegratedATSPreferSourceB(3)}read-writemandatory
upsIntegratedATSUpsReturnStaggering
OBJECT-TYPE
This is a delay factor applied to the retransfer of this UPS with integrated ATS. When multiple UPSs are in use from a single source, each UPS can have a unique delay value, which will reduce inrush by preventing all UPSs from transferring at the same time.
1.3.6.1.4.1.318.1.1.1.16.3INTEGERread-writemandatory
upsIntegratedATSSourceTableSize
OBJECT-TYPE
The number of input sources for this integrated ATS.
1.3.6.1.4.1.318.1.1.1.16.4INTEGERread-onlymandatory
upsIntegratedATSSourceTable
OBJECT-TYPE
Allows for getting status and settings for the ATS input sources. The number of entries is contained in the upsIntegratedATSSourceTableSize OID.
1.3.6.1.4.1.318.1.1.1.16.5not-accessiblemandatory
upsIntegratedATSSourceEntry
OBJECT-TYPE
The input source status to get.
1.3.6.1.4.1.318.1.1.1.16.5.1not-accessiblemandatory
upsIntegratedATSSourceIndex
OBJECT-TYPE
The index to the input source entry.
1.3.6.1.4.1.318.1.1.1.16.5.1.1INTEGERread-onlymandatory
upsIntegratedATSSourceName
OBJECT-TYPE
The name of the input source. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.1.16.5.1.2DisplayStringread-onlymandatory
upsIntegratedATSSourceStatus
OBJECT-TYPE
Getting this variable will return the input source status.
1.3.6.1.4.1.318.1.1.1.16.5.1.3INTEGER {upsIntegratedATSSourceGood(1), upsIntegratedATSSourceBad(2), upsIntegratedATSSourceUnknown(3)}read-onlymandatory
upsIntegratedATSLineFailDelay
OBJECT-TYPE
The delay between a selected input source becoming bad, and the ATS switching away from that source. This delay is used to make sure that the line has truly failed before the ATS will be switched. Specified in seconds.
1.3.6.1.4.1.318.1.1.1.16.5.1.4INTEGERread-writemandatory
upsIntegratedATSLineStabilityDelay
OBJECT-TYPE
The delay between an unselected input source becoming good, and the ATS switching to that source. This delay is used to make sure that the line has truly returned before the ATS will be switched. Specified in seconds.
1.3.6.1.4.1.318.1.1.1.16.5.1.5INTEGERread-writemandatory
upsDCOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.17
upsDCOutputStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.17.1
upsDCOutputStatusTableSize
OBJECT-TYPE
The number of DC outputs on the UPS.
1.3.6.1.4.1.318.1.1.1.17.1.1INTEGERread-onlymandatory
upsDCOutputStatusTable
OBJECT-TYPE
Provides status information on UPS DC outputs. The number of entries is contained in the upsDCOutputStatusTableSize OID.
1.3.6.1.4.1.318.1.1.1.17.1.2not-accessiblemandatory
upsDCOutputStatusEntry
OBJECT-TYPE
The DC output.
1.3.6.1.4.1.318.1.1.1.17.1.2.1not-accessiblemandatory
upsDCOutputStatusTableIndex
OBJECT-TYPE
The index to the DC output status entry.
1.3.6.1.4.1.318.1.1.1.17.1.2.1.1INTEGERread-onlymandatory
upsDCOutputStatusVoltageNominal
OBJECT-TYPE
The desired voltage for this output in tenths of VDC. When the output is on and there are no fault conditions, the actual voltage should be near the nominal.
1.3.6.1.4.1.318.1.1.1.17.1.2.1.2INTEGERread-onlymandatory
upsDCOutputStatusCurrentRating
OBJECT-TYPE
The amount of current this output is able to supply in tenths of amperes.
1.3.6.1.4.1.318.1.1.1.17.1.2.1.3INTEGERread-onlymandatory
upsDCOutputStatusVoltage
OBJECT-TYPE
The voltage measured on this output in tenths of VDC.
1.3.6.1.4.1.318.1.1.1.17.1.2.1.4INTEGERread-onlymandatory
upsDCOutputStatusCurrent
OBJECT-TYPE
The current drawn by the load measured on this output in tenths of amperes.
1.3.6.1.4.1.318.1.1.1.17.1.2.1.5INTEGERread-onlymandatory
upsDCOutputStatusAbnormalConditions
OBJECT-TYPE
An ASCII string containing flags representing active output faults. If the Network Card is unable to determine the state of the faults, this variable is set to 'UNKNOWN'. The flags are numbered 1 onward, read from left to right. The flags are defined as follows starting from 1: Flag 1: Output Overload Flag 2: Output Short Circuit Flag 3: Output Over Voltage Flag 4: <Not Used> Flag 5: Overtemperature Flag 6: Backfeed Relay Fault Flag 7: <Not Used> Flag 8: PFC Input Relay Fault Flag 9: <Not Used> Flag 10: Bypass Relay Fault Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used> Flag 17: <Not Used> Flag 18: <Not Used> Flag 19: Output Fault (over or undervoltage) Flag 20: Bus Converter Fault Flag 21: Sensor Fault Flag 21: <Not Used> Flag 22: <Not Used> Flag 23: <Not Used> Flag 24: <Not Used> Flag 25: <Not Used> Flag 26: <Not Used> Flag 27: <Not Used> Flag 28: <Not Used> Flag 29: <Not Used> Flag 30: <Not Used> Flag 31: <Not Used> Flag 32: <Not Used>
1.3.6.1.4.1.318.1.1.1.17.1.2.1.6DisplayStringread-onlymandatory
upsIntegratedUIO
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.18
upsOutputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.18.1
upsOutputRelayStatusTableSize
OBJECT-TYPE
The number of integrated output relays on the UPS.
1.3.6.1.4.1.318.1.1.1.18.1.1INTEGERread-onlymandatory
upsOutputRelayStatusTable
OBJECT-TYPE
Allows for access of individual relays.
1.3.6.1.4.1.318.1.1.1.18.1.2not-accessiblemandatory
upsOutputRelayStatusEntry
OBJECT-TYPE
The output relays to access.
1.3.6.1.4.1.318.1.1.1.18.1.2.1not-accessiblemandatory
upsOutputRelayIndex
OBJECT-TYPE
The index to the output relay entry.
1.3.6.1.4.1.318.1.1.1.18.1.2.1.1INTEGERread-onlymandatory
upsOutputRelayState
OBJECT-TYPE
Getting this variable will return the output relay state. 1 - normal state 2 - abnormal state
1.3.6.1.4.1.318.1.1.1.18.1.2.1.2INTEGER {outputRelayNormalState(1), outputRelayAbnormalState(2)}read-onlymandatory
upsOutputRelayDetailedStatus
OBJECT-TYPE
An ASCII string containing the 16 flags representing the status of the output relay. The flags are numbered from 1 to 16, and read from left to right. The bits are defined as follows: Flag 1: Cause is true which makes the output relay active if not pending a condition Flag 2: Pending delay Flag 3: Pending peak period Flag 4: <Not Used> Flag 5: <Not Used> Flag 6: <Not Used> Flag 7: <Not Used> Flag 8: <Not Used> Flag 9: <Not Used> Flag 10: <Not Used> Flag 11: <Not Used> Flag 12: <Not Used> Flag 13: <Not Used> Flag 14: <Not Used> Flag 15: <Not Used> Flag 16: <Not Used>
1.3.6.1.4.1.318.1.1.1.18.1.2.1.3DisplayStringread-onlymandatory
upsOutputRelayConfigTableSize
OBJECT-TYPE
The number of integrated output relays on the UPS.
1.3.6.1.4.1.318.1.1.1.18.1.3INTEGERread-onlymandatory
upsOutputRelayConfigTable
OBJECT-TYPE
Allows for access of individual relays.
1.3.6.1.4.1.318.1.1.1.18.1.4not-accessiblemandatory
upsOutputRelayConfigEntry
OBJECT-TYPE
The output relays to access.
1.3.6.1.4.1.318.1.1.1.18.1.4.1not-accessiblemandatory
upsOutputRelayConfigIndex
OBJECT-TYPE
The index to the output relay entry.
1.3.6.1.4.1.318.1.1.1.18.1.4.1.1INTEGERread-onlymandatory
upsOutputRelayConfigDelay
OBJECT-TYPE
Output relay delay 0 - 86400 seconds.
1.3.6.1.4.1.318.1.1.1.18.1.4.1.2INTEGERread-writemandatory
upsOutputRelayConfigCause
OBJECT-TYPE
This variable sets what causes the output relay state to change. 1 - none 2 - on battery power failure 3 - on battery power failure expect during peak period 4 - low battery while on battery 5 - alarm 6 - fault 7 - output on 8 - output off 9 - online 10 - in bypass
1.3.6.1.4.1.318.1.1.1.18.1.4.1.3INTEGER {outputRelayConfigCauseNone(1), outputRelayConfigCauseOnBatPwrFail(2), outputRelayConfigCauseOnBatPwrFailExceptPeakPeriod(3), outputRelayConfigCauseLoBatWhileOnBat(4), outputRelayConfigCauseAlarm(5), outputRelayConfigCauseFault(6), outputRelayConfigCauseOutputOn(7), outputRelayConfigCauseOutputOff(8), outputRelayConfigCauseOnline(9), outputRelayConfigCauseInBypass(10)}read-writemandatory
upsOutputRelayConfigPolarity
OBJECT-TYPE
Configures all output relays with one setting. 1 - all relays act normally open, when logic condition is true, relays are energized 2 - all relays act normally close, when logic condition is true relays are deenergized
1.3.6.1.4.1.318.1.1.1.18.1.5INTEGER {upsOutputRelayAllRelaysEnergizedWhenTrue(1), upsOutputRelayAllRelaysNotEnergizedWhenTrue(2)}read-writemandatory
upsOutputRelayConfigPeakPeriod
OBJECT-TYPE
An ASCII string containing the 64 flags representing the peak period setting of the UPS. Flags are numbered 1-64 starting from the left. Each flag is either a '1', representing a flag that is set, or a '0', representing a flag that is /not/ set. The peak period intervals are times that are both: - on the days of the week set by the first 7 flags AND - within the time periods set by the remaining flags. UPS output relays triggered by 'On battery except peak period' will not signal when the UPS is on battery during a peak period. The flags are defined as follows: Flag 1: Sunday Flag 2: Monday Flag 3: Tuesday Flag 4: Wednesday Flag 5: Thursday Flag 6: Friday Flag 7: Saturday Flag 8: 00:00-00:29 Flag 9: 00:30-00:59 Flag 10: 01:00-01:29 Flag 11: 01:30-01:59 Flag 12: 02:00-02:29 Flag 13: 02:30-02:59 Flag 14: 03:00-03:29 Flag 15: 03:30-03:59 Flag 16: 04:00-04:29 Flag 17: 04:30-04:59 Flag 18: 05:00-05:29 Flag 19: 05:30-05:59 Flag 20: 06:00-06:29 Flag 21: 06:30-06:59 Flag 22: 07:00-07:29 Flag 23: 07:30-07:59 Flag 24: 08:00-08:29 Flag 25: 08:30-08:59 Flag 26: 09:00-09:29 Flag 27: 09:30-09:59 Flag 28: 10:00-00:29 Flag 29: 10:30-10:59 Flag 30: 11:00-11:29 Flag 31: 11:30-11:59 Flag 32: 12:00-12:29 Flag 33: 12:30-12:59 Flag 34: 13:00-13:29 Flag 35: 13:30-13:59 Flag 36: 14:00-14:29 Flag 37: 14:30-14:59 Flag 38: 15:00-15:29 Flag 39: 15:30-15:59 Flag 40: 16:00-16:29 Flag 41: 16:30-16:59 Flag 42: 17:00-17:29 Flag 43: 17:30-17:59 Flag 44: 18:00-18:29 Flag 45: 18:30-18:59 Flag 46: 19:00-19:29 Flag 47: 19:30-19:59 Flag 48: 20:00-20:29 Flag 49: 20:30-20:59 Flag 50: 21:00-21:29 Flag 51: 21:30-21:59 Flag 52: 22:00-22:29 Flag 53: 22:30-22:59 Flag 54: 23:00-23:29 Flag 55: 23:30-23:59 Flag 56: <Not Used> Flag 57: <Not Used> Flag 58: <Not Used> Flag 59: <Not Used> Flag 60: <Not Used> Flag 61: <Not Used> Flag 62: <Not Used> Flag 63: <Not Used> Flag 64: <Not Used> To set this OID you can either: - set the 64 flag bits as an ASCII string of '1's and '0's as described above. The same format is used when this OID is read. - or turn on/off an individual flags. Examples: Set for Sundays and Tuesdays from 00:00-01:29: 1010000111000000000000000000000000000000000000000000000000000000 Set Mondays to be part of the peak periods: +2 Set Tuesdays to not be part of the peak periods: -3 Include interval 23:30-23:59 in the peak period: +55
1.3.6.1.4.1.318.1.1.1.18.1.6DisplayStringread-writemandatory
upsInputContacts
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.18.2
upsInputContactStatusTableSize
OBJECT-TYPE
The number of integrated input contacts on the UPS.
1.3.6.1.4.1.318.1.1.1.18.2.1INTEGERread-onlymandatory
upsInputContactStatusTable
OBJECT-TYPE
Allows for access of individual contacts.
1.3.6.1.4.1.318.1.1.1.18.2.2not-accessiblemandatory
upsInputContactStatusEntry
OBJECT-TYPE
The input contacts to access.
1.3.6.1.4.1.318.1.1.1.18.2.2.1not-accessiblemandatory
upsInputContactIndex
OBJECT-TYPE
The index to the input contact entry.
1.3.6.1.4.1.318.1.1.1.18.2.2.1.1INTEGERread-onlymandatory
upsInputContactState
OBJECT-TYPE
Getting this variable will return the input contact state. 1 - normal state 2 - abnormal state
1.3.6.1.4.1.318.1.1.1.18.2.2.1.2INTEGER {upsInputContactNormalState(1), upsInputContactAbnormalState(2)}read-onlymandatory
upsInputContactConfigTableSize
OBJECT-TYPE
The number of integrated input contacts on the UPS.
1.3.6.1.4.1.318.1.1.1.18.2.3INTEGERread-onlymandatory
upsInputContactConfigTable
OBJECT-TYPE
Allows for access of individual contacts.
1.3.6.1.4.1.318.1.1.1.18.2.4not-accessiblemandatory
upsInputContactConfigEntry
OBJECT-TYPE
The input contacts to access.
1.3.6.1.4.1.318.1.1.1.18.2.4.1not-accessiblemandatory
upsInputContactConfigIndex
OBJECT-TYPE
The index to the input contact entry.
1.3.6.1.4.1.318.1.1.1.18.2.4.1.1INTEGERread-onlymandatory
upsInputContactConfigAction
OBJECT-TYPE
When the input contact changes state, this action occurs. 1 - none 2 - self test 3 - external alarm on 4 - external alarm off 5 - output off no delay 6 - output on
1.3.6.1.4.1.318.1.1.1.18.2.4.1.2INTEGER {upsInputContactConfigActionNone(1), upsInputContactConfigActionSelfTest(2), upsInputContactConfigActionExternalAlarmOn(3), upsInputContactConfigActionExternalAlarmOff(4), upsInputContactConfigActionOutputOffNoDelay(5), upsInputContactConfigActionOutputOn(6)}read-writemandatory
upsInputContactConfigPolarity
OBJECT-TYPE
Configures all input contacts with one setting. 1 - all contacts act as normally open 2 - all contacts act as normally closed
1.3.6.1.4.1.318.1.1.1.18.2.5INTEGER {upsInputContactAllContactsClosedEqualsTrue(1), upsInputContactAllContactsOpenEqualsTrue(2)}read-writemandatory
upsEnergyEfficiency
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.20
upsECOmode
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.20.1
upsEcoModeFreqTransferRange
OBJECT-TYPE
Indicates tolerance of bypass AC frequency in Hz to switch on ECO mode.
1.3.6.1.4.1.318.1.1.1.20.1.1INTEGERread-onlymandatory
upsEcoModeHighVoltThreshold
OBJECT-TYPE
Indicates high threshold on AC voltage in volts to switch on ECO mode.
1.3.6.1.4.1.318.1.1.1.20.1.2INTEGERread-onlymandatory
upsEcoModeLowVoltThreshold
OBJECT-TYPE
Indicates low threshold on AC voltage in volts to switch on ECO mode.
1.3.6.1.4.1.318.1.1.1.20.1.3INTEGERread-onlymandatory
upsEcoModeSetting
OBJECT-TYPE
Indicates whether ECO feature is avaiable to this UPS or not.
1.3.6.1.4.1.318.1.1.1.20.1.4INTEGER {enabled(1), disabled(2)}read-onlymandatory
upsEcoModeStatus
OBJECT-TYPE
Indicates whether UPS is running in ECO mode or not.
1.3.6.1.4.1.318.1.1.1.20.1.5INTEGER {active(1), inactive(2)}read-onlymandatory
upsEcoModeCountSinceReset
OBJECT-TYPE
Number of times UPS entered into ECO mode since maintenance reset.
1.3.6.1.4.1.318.1.1.1.20.1.6INTEGERread-onlymandatory
upsEcoModeOnlineSinceCommission
OBJECT-TYPE
Total runtime in online mode with ECO feature enabled once product is authorized to use (in minutes).
1.3.6.1.4.1.318.1.1.1.20.1.7INTEGERread-onlymandatory
upsEcoModeOnlineSinceReset
OBJECT-TYPE
Total runtime in online mode with ECO feature enabled since maintenance reset (in minutes).
1.3.6.1.4.1.318.1.1.1.20.1.8INTEGERread-onlymandatory
upsEcoModeTotalPercentTimeSinceReset
OBJECT-TYPE
Indicates percentage of runtime in ECO mode since maintenance reset.
1.3.6.1.4.1.318.1.1.1.20.1.9INTEGERread-onlymandatory
upsEcoModePercentTimeSinceCommission
OBJECT-TYPE
Indicates percentage of operation time in ECO mode once product is authorized to use.
1.3.6.1.4.1.318.1.1.1.20.1.10INTEGERread-onlymandatory
upsEcoModeTotalTimeSinceReset
OBJECT-TYPE
Total runtime of UPS in ECO mode since maintenance reset (in minutes).
1.3.6.1.4.1.318.1.1.1.20.1.11INTEGERread-onlymandatory
upsEcoModeTotalTimeSinceCommission
OBJECT-TYPE
Total runtime in ECO mode once product is authorized to use (in minutes).
1.3.6.1.4.1.318.1.1.1.20.1.12INTEGERread-onlymandatory
upsEcoModeTotalTimeInMonth
OBJECT-TYPE
Total runtime of UPS in ECO mode since beginning of month (in minutes).
1.3.6.1.4.1.318.1.1.1.20.1.13INTEGERread-onlymandatory
upsEBMmode
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.20.2
upsEbmModeSetting
OBJECT-TYPE
Indicates whether efficiency booster mode feature is avaiable to this UPS or not.
1.3.6.1.4.1.318.1.1.1.20.2.1INTEGER {enabled(1), disabled(2)}read-onlymandatory
upsEbmModeStatus
OBJECT-TYPE
Indicates whether UPS is running on EBM mode or not.
1.3.6.1.4.1.318.1.1.1.20.2.2INTEGER {active(1), inactive(2)}read-onlymandatory
upsEbmModeCountSinceReset
OBJECT-TYPE
Number of times UPS entered into efficiency booster mode since maintenance reset.
1.3.6.1.4.1.318.1.1.1.20.2.3INTEGERread-onlymandatory
upsEbmModeTotalTimeInMonth
OBJECT-TYPE
Total runtime of UPS in efficiency booster mode since beginning of month (in minutes).
1.3.6.1.4.1.318.1.1.1.20.2.4INTEGERread-onlymandatory
upsEbmModeTotalTimeSinceReset
OBJECT-TYPE
Total runtime of UPS in efficiency booster mode since maintenance reset (in minutes).
1.3.6.1.4.1.318.1.1.1.20.2.5INTEGERread-onlymandatory
upsEbmModeTotalPercentTimeSinceReset
OBJECT-TYPE
Indicates percentage of runtime in efficiency booster mode since maintenance reset.
1.3.6.1.4.1.318.1.1.1.20.2.6INTEGERread-onlymandatory
upsEbmModeOnlineSinceCommission
OBJECT-TYPE
Indicates runtime in online mode with EBM feature enabled once product is authorized to use (in minutes).
1.3.6.1.4.1.318.1.1.1.20.2.7INTEGERread-onlymandatory
upsEbmModePercentTimeSinceCommission
OBJECT-TYPE
Indicates percentage of operation time in efficiency booster mode once product is authorized to use.
1.3.6.1.4.1.318.1.1.1.20.2.8INTEGERread-onlymandatory
upsEbmModeRuntimeSinceCommission
OBJECT-TYPE
Total runtime in efficiency booster mode once product is authorized to use (in minutes).
1.3.6.1.4.1.318.1.1.1.20.2.9INTEGERread-onlymandatory
upsEbmModeOnlineSinceReset
OBJECT-TYPE
Total runtime in online mode with EBM feature enabled since maintenance reset (in minutes).
1.3.6.1.4.1.318.1.1.1.20.2.10INTEGERread-onlymandatory
upsEbmModeUpsCount
OBJECT-TYPE
Number of UPS's running in efficiency booster mode.
1.3.6.1.4.1.318.1.1.1.20.2.11INTEGERread-onlymandatory
upsStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.22
upsBatteryStats
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.22.1
upsBatteryStatsReset
OBJECT-TYPE
Setting this OID to reset(3) will reset the Battery Stats timer. Getting this OID will return: notSupported(1) - reset feature is not supported. noOperation(2) - indicates reset is supported, does nothing.
1.3.6.1.4.1.318.1.1.1.22.1.1INTEGER {notSupported(1), noOperation(2), reset(3)}read-writemandatory
upsBatteryStatsTimeSinceReset
OBJECT-TYPE
Time since battery timer reset (in minutes).
1.3.6.1.4.1.318.1.1.1.22.1.2INTEGERread-onlymandatory
upsBatteryStatsTimeOnBattery
OBJECT-TYPE
Total time for UPS in battery operation (in minutes).
1.3.6.1.4.1.318.1.1.1.22.1.3INTEGERread-onlymandatory
upsOperationalStats
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.22.2
upsOpStatsReset
OBJECT-TYPE
Setting this OID to reset(3) will reset the Operational Stats timer. Getting this OID will return: notSupported(1) - reset feature is not supported. noOperation(2) - indicates reset is supported, does nothing.
1.3.6.1.4.1.318.1.1.1.22.2.1INTEGER {notSupported(1), noOperation(2), reset(3)}read-writemandatory
upsOpStatsTimeSinceReset
OBJECT-TYPE
Time since timer reset (in minutes).
1.3.6.1.4.1.318.1.1.1.22.2.2INTEGERread-onlymandatory
upsOpStatsTimeInNormalOperation
OBJECT-TYPE
Total time for UPS in normal operation since timer reset via upsOpStatsReset (in minutes).
1.3.6.1.4.1.318.1.1.1.22.2.3INTEGERread-onlymandatory
upsOpStatsTimeInBypassOperation
OBJECT-TYPE
Total time for UPS in bypass operation since timer reset via upsOpStatsReset (in minutes).
1.3.6.1.4.1.318.1.1.1.22.2.4INTEGERread-onlymandatory
upsOpStatsTimeInECOmodeOperation
OBJECT-TYPE
Total time for UPS in ECO mode since timer reset via upsOpStatsReset (in minutes).
1.3.6.1.4.1.318.1.1.1.22.2.5INTEGERread-onlymandatory
upsOpStatsTimeInECOnversionOperation
OBJECT-TYPE
Total time for UPS in ECOnversion since timer reset via upsOpStatsReset (in minutes).
1.3.6.1.4.1.318.1.1.1.22.2.6INTEGERread-onlymandatory
upsEnergyEfficiencyStats
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.1.22.3
upsEnergyEfficiencyStatsReset
OBJECT-TYPE
Setting this OID to reset(3) will reset the Energy Efficiency Stats timer. Getting this OID will return: notSupported(1) - reset feature is not supported. noOperation(2) - indicates reset is supported, does nothing.
1.3.6.1.4.1.318.1.1.1.22.3.1INTEGER {notSupported(1), noOperation(2), reset(3)}read-writemandatory
upsEnergyEfficiencyStatsOutputEnergyTimeSinceReset
OBJECT-TYPE
Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsOutputEnergyUsage
1.3.6.1.4.1.318.1.1.1.22.3.2INTEGERread-onlymandatory
upsEnergyEfficiencyStatsTimeInECOmode
OBJECT-TYPE
Total time (in minutes) for UPS in ECO mode since last timer reset via upsEnergyEfficiencyStatsReset
1.3.6.1.4.1.318.1.1.1.22.3.3INTEGERread-onlyoptional
upsEnergyEfficiencyStatsTimeInECOnversion
OBJECT-TYPE
Total time (in minutes) for UPS in ECOnversion since last timer reset via upsEnergyEfficiencyStatsReset
1.3.6.1.4.1.318.1.1.1.22.3.4INTEGERread-onlyoptional
upsEnergyEfficiencyStatsInputEnergyUsage
OBJECT-TYPE
The input energy usage of the UPS in kWh since timer reset.
1.3.6.1.4.1.318.1.1.1.22.3.5INTEGERread-onlymandatory
upsEnergyEfficiencyStatsOutputEnergyUsage
OBJECT-TYPE
The output energy usage of the UPS in kWh since timer reset.
1.3.6.1.4.1.318.1.1.1.22.3.6INTEGERread-onlymandatory
upsEnergyEfficiencyStatsInputEnergyTimeSinceReset
OBJECT-TYPE
Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsInputEnergyUsage
1.3.6.1.4.1.318.1.1.1.22.3.7INTEGERread-onlymandatory
upsEnergyEfficiencyStatsECOmodeTimeSinceReset
OBJECT-TYPE
Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsTimeInECOmode
1.3.6.1.4.1.318.1.1.1.22.3.8INTEGERread-onlyoptional
upsEnergyEfficiencyStatsECOnversionTimeSinceReset
OBJECT-TYPE
Time (in minutes) since last timer reset of the OID upsEnergyEfficiencyStatsTimeInECOnversion
1.3.6.1.4.1.318.1.1.1.22.3.9INTEGERread-onlyoptional
measureUps
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.2
mUpsEnviron
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.2.1
mUpsEnvironAmbientTemperature
OBJECT-TYPE
The ambient temperature in Celsius for Probe 1.
1.3.6.1.4.1.318.1.1.2.1.1Gaugeread-onlymandatory
mUpsEnvironRelativeHumidity
OBJECT-TYPE
The relative humidity as a percentage for Probe 1.
1.3.6.1.4.1.318.1.1.2.1.2Gaugeread-onlymandatory
mUpsEnvironAmbientTemperature2
OBJECT-TYPE
The ambient temperature in Celsius for Probe 2.
1.3.6.1.4.1.318.1.1.2.1.3Gaugeread-onlymandatory
mUpsEnvironRelativeHumidity2
OBJECT-TYPE
The relative humidity as a percentage for Probe 2.
1.3.6.1.4.1.318.1.1.2.1.4Gaugeread-onlymandatory
mUpsContact
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.2.2
mUpsContactNumContacts
OBJECT-TYPE
The number of contacts supported by the Measure-UPS.
1.3.6.1.4.1.318.1.1.2.2.1INTEGERread-onlymandatory
mUpsContactTable
OBJECT-TYPE
A list of contacts supported by the Measure-UPS.
1.3.6.1.4.1.318.1.1.2.2.2not-accessiblemandatory
mUpsContactEntry
OBJECT-TYPE
A contact entry containing information for a given contact.
1.3.6.1.4.1.318.1.1.2.2.2.1not-accessiblemandatory
contactNumber
OBJECT-TYPE
An index identifying the contact on the Measure-UPS.
1.3.6.1.4.1.318.1.1.2.2.2.1.1INTEGERread-onlymandatory
normalState
OBJECT-TYPE
The normal operating position of the contact. If the normal operating position cannot be set then it is controlled via the dip switch on the Measure-UPS and is therefore read-only.
1.3.6.1.4.1.318.1.1.2.2.2.1.2INTEGER {unknown(1), open(2), closed(3)}read-writemandatory
description
OBJECT-TYPE
The description of the purpose/use of the contact.
1.3.6.1.4.1.318.1.1.2.2.2.1.3DisplayStringread-writemandatory
monitoringStatus
OBJECT-TYPE
A flag indicating whether this contact is monitored, or not.
1.3.6.1.4.1.318.1.1.2.2.2.1.4INTEGER {unknown(1), enabled(2), disabled(3)}read-writemandatory
currentStatus
OBJECT-TYPE
This value indicates the current state of the contact. If the contact is not in its normal state. This value is set to fault(2).
1.3.6.1.4.1.318.1.1.2.2.2.1.5INTEGER {unknown(1), noFault(2), fault(3)}read-onlymandatory
miniSNMPadapter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.3
serialPort
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.3.1
serialPort1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.3.1.1
serialPort2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.3.1.2
serialPort2Config
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.3.1.2.1
serialPort2Mode
OBJECT-TYPE
Setting this variable to passthrough will enable mini's port2 behave like a UPS port. Choosing localConsole will enable the port to be used as local console.
1.3.6.1.4.1.318.1.1.3.1.2.1.1INTEGER {localConsole(1), passthrough(2)}read-writeobsolete
serialPort2Control
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.3.1.2.2
setPulseOnTXD
OBJECT-TYPE
Setting this variable to setPulseOnTXD(2) causes adapter to generate a PULSE on TXD pin of serial port 2. The duration in the prototype implementation will be 1 second. Setting this value to noSetPulseOnTXD(1) has no effect. The value noSetPulseOnTXD(1) will always be returned when the variable is read. Setting this value to setTXDLow(3), or setTXDHigh(4) will keep TXD always low or high respectively.
1.3.6.1.4.1.318.1.1.3.1.2.2.1INTEGER {noSetPulseOnTXD(1), setPulseOnTXD(2), setTXDLow(3), setTXDHigh(4)}read-writeobsolete
masterswitch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.4
sPDUIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.4.1
sPDUIdentHardwareRev
OBJECT-TYPE
The hardware revision of the PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.4.1.1DisplayStringread-onlymandatory
sPDUIdentFirmwareRev
OBJECT-TYPE
An 8 byte ID string identifying the PDU firmware revision. This value is set at the factory.
1.3.6.1.4.1.318.1.1.4.1.2DisplayStringread-onlymandatory
sPDUIdentDateOfManufacture
OBJECT-TYPE
The date when the PDU was manufactured in mm/dd/yy format. This value is set at the factory. The year 2000 will be represented by 00.
1.3.6.1.4.1.318.1.1.4.1.3DisplayStringread-onlymandatory
sPDUIdentModelNumber
OBJECT-TYPE
A 10-character string identifying the model number of the PDU internal. This value is set at the factory.
1.3.6.1.4.1.318.1.1.4.1.4DisplayStringread-onlymandatory
sPDUIdentSerialNumber
OBJECT-TYPE
A 12-character string identifying the serial number of the PDU internal microprocessor. This value is set at the factory.
1.3.6.1.4.1.318.1.1.4.1.5DisplayStringread-onlymandatory
sPDUMasterControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.4.2
sPDUMasterControlSwitch
OBJECT-TYPE
Setting this OID to turnAllOnNow (1) will turn all outlets on immediately. Setting this OID to turnAllOnSequence (2) will turn all outlets on as defined by each outlet's sPDUOutletPowerOnTime OID value. Setting this OID to turnAllOff (3) will turn all outlets off immediately. Setting this OID to rebootAllNow (4) will reboot all outlets immediately. For MasterSwitch firmware version 1.X, setting this OID to rebootAllSequence (5) reboots all outlets, with power returned to the outlets in the sequence defined by each outlet's sPDUOutletPowerOnTime OID value. For MasterSwitch firmware version 2.X, setting this OID to rebootAllSequence (5) will cause a turnAllOffSequence to be performed. Once all outlets are off, the MasterSwitch will then delay the sPDUMasterConfigReboot OID time, and then perform a turnAllOnSequence. For MasterSwitch firmware version 2.X, setting this OID to turnAllOffSequence (7) will turn all outlets off as defined by each outlet's sPDUOutletPowerOffTime OID value. For MasterSwitch firmware version 1.X, setting this OID to turnAllOffSequence (7) will have no effect. Getting this OID will return the noCommand (6) value.
1.3.6.1.4.1.318.1.1.4.2.1INTEGER {turnAllOnNow(1), turnAllOnSequence(2), turnAllOffNow(3), rebootAllNow(4), rebootAllSequence(5), noCommand(6), turnAllOffSequence(7)}read-writemandatory
sPDUMasterState
OBJECT-TYPE
Getting this OID will cause the status of all outlets to be returned. This OID is provided for informational purposes only. To change the outlet state, the user should use the sPDUOutletCtl OID in the sPDUOutletControlTable. The format of the data returned is a character string consisting of the word 'On' if the outlet is on or 'Off' if the outlet is off. At least one space will delimit each outlet entry in the string. If the outlet states are unknown, the character string 'Unknown' will be returned. This signifies that there is an inconsistency in the PDU. In the rare case that this should happen, the user is advised to shut down all equipment powered by the PDU and then cycle the PDU's power. This will put the PDU in a consistent state.
1.3.6.1.4.1.318.1.1.4.2.2DisplayStringread-onlymandatory
sPDUMasterPending
OBJECT-TYPE
Getting this OID will cause the command pending status of all outlets to be returned. The format of the data returned is a character string consisting of the word 'Yes' if a command is pending for the outlet or 'No' if there is no command pending for the outlet. At least one space will delimit each outlet entry in the string. If the pending states are unknown, the character string 'Unknown' will be returned. This signifies that there is an inconsistency in the PDU. In the rare case that this should happen, the user is advised to shut down all equipment powered by the PDU and then cycle the PDU's power. This will put the PDU in a consistent state.
1.3.6.1.4.1.318.1.1.4.2.3DisplayStringread-onlymandatory
sPDUMasterConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.4.3
sPDUMasterConfigPowerOn
OBJECT-TYPE
The amount of delay, in seconds, between when power is provided to the PDU and when the PDU provides basic master power to the outlets. Allowed values are: -1 never apply power automatically. 0 apply power immediately. 15 apply power in 15 seconds. 30 apply power in 30 seconds. 45 apply power in 45 seconds. 60 apply power in 60 seconds (1 minute). 120 apply power in 120 seconds (2 minutes). 300 apply power in 300 seconds (5 minutes). If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.4.3.1INTEGERread-writemandatory
sPDUMasterConfigReboot
OBJECT-TYPE
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is read-only for the MasterSwitch version 2.X and is the maximum sPDUOutletRebootDuration OID of the individual outlets.
1.3.6.1.4.1.318.1.1.4.3.2INTEGERread-writemandatory
sPDUMasterConfigPDUName
OBJECT-TYPE
The name of the PDU.
1.3.6.1.4.1.318.1.1.4.3.3DisplayStringread-writemandatory
sPDUOutletControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.4.4
sPDUOutletControlTableSize
OBJECT-TYPE
The number of outlets for the PDU.
1.3.6.1.4.1.318.1.1.4.4.1INTEGERread-onlymandatory
sPDUOutletControlTable
OBJECT-TYPE
Allows for control of individual outlet switches. The number of entries is contained in the sPDUOutletControlTableSize OID.
1.3.6.1.4.1.318.1.1.4.4.2not-accessiblemandatory
sPDUOutletControlEntry
OBJECT-TYPE
The outlets to control.
1.3.6.1.4.1.318.1.1.4.4.2.1not-accessiblemandatory
sPDUOutletControlIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.4.4.2.1.1INTEGERread-onlymandatory
sPDUOutletPending
OBJECT-TYPE
Reports whether the current outlet has a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition.
1.3.6.1.4.1.318.1.1.4.4.2.1.2INTEGER {commandPending(1), noCommandPending(2), commandPendingUnknown(3)}read-onlymandatory
sPDUOutletCtl
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the outletOn (1) value will be returned. If the outlet is off, the outletOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to outletOn (1) will turn the outlet on. Setting this variable to outletOff (2) will turn the outlet off. Setting this variable to outletReboot (3) will reboot the outlet. Setting this variable to outletOnWithDelay (5) will turn the outlet on after the sPDUOutletPowerOnTime OID has elapsed. This option is not valid for MasterSwitch firmware version 1.X. Setting this variable to outletOffWithDelay (6) will turn the outlet off after the sPDUOutletPowerOffTime OID has elapsed. This option is not valid for MasterSwitch firmware version 1.X. Setting this variable to outletRebootWithDelay (7) will turn the outlet off after the sPDUOutletPowerOffTime OID has elapsed, wait the sPDUOutletRebootDuration OID time, then turn the outlet back on. This option is not valid for MasterSwitch firmware version 1.X.
1.3.6.1.4.1.318.1.1.4.4.2.1.3INTEGER {outletOn(1), outletOff(2), outletReboot(3), outletUnknown(4), outletOnWithDelay(5), outletOffWithDelay(6), outletRebootWithDelay(7)}read-writemandatory
sPDUOutletCtlName
OBJECT-TYPE
The name of the outlet. Maximum size is 20 characters. This OID is provided for informational purposes only. This value is set by the sPDUOutletName OID.
1.3.6.1.4.1.318.1.1.4.4.2.1.4DisplayStringread-onlymandatory
sPDUOutletConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.4.5
sPDUOutletConfigTableSize
OBJECT-TYPE
The number of outlets for the PDU.
1.3.6.1.4.1.318.1.1.4.5.1INTEGERread-onlymandatory
sPDUOutletConfigTable
OBJECT-TYPE
The list of outlets to configure. The number of entries is defined by the sPDUOutletConfigTableSize OID.
1.3.6.1.4.1.318.1.1.4.5.2not-accessiblemandatory
sPDUOutletConfigEntry
OBJECT-TYPE
The outlets to control.
1.3.6.1.4.1.318.1.1.4.5.2.1not-accessiblemandatory
sPDUOutletConfigIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.4.5.2.1.1INTEGERread-onlymandatory
sPDUOutletPowerOnTime
OBJECT-TYPE
The amount of time (in seconds) the outlet will delay powering on when the MasterSwitch is powered on. Allowed values are: -1 never power on automatically. 0 power on with the Master Switch. 15 power on 15 seconds after the MasterSwitch has power applied. 30 power on 30 seconds after the MasterSwitch has power applied. 45 power on 45 seconds after the MasterSwitch has power applied. 60 power on 60 seconds (1 minute) after the MasterSwitch has power applied. 120 power on 120 seconds (2 minutes) after the MasterSwitch has power applied. 300 power on 300 seconds (5 minutes) after the MasterSwitch has power applied. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.4.5.2.1.2INTEGERread-writemandatory
sPDUOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 20 characters.
1.3.6.1.4.1.318.1.1.4.5.2.1.3DisplayStringread-writemandatory
sPDUOutletPowerOffTime
OBJECT-TYPE
The amount of time (in seconds) the outlet will delay powering off. Allowed values are: -1 never power off automatically. 0 power off with the MasterSwitch. 15 power off 15 seconds after being commanded. 30 power off 30 seconds after being commanded. 45 power off 45 seconds after being commanded. 60 power off 60 seconds (1 minute) after being commanded. 120 power off 120 seconds (2 minutes) after being commanded. 300 power off 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is not available for MasterSwitch firmware version 1.X.
1.3.6.1.4.1.318.1.1.4.5.2.1.4INTEGERread-writemandatory
sPDUOutletRebootDuration
OBJECT-TYPE
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the PDU interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. This OID is not available for MasterSwitch firmware version 1.X.
1.3.6.1.4.1.318.1.1.4.5.2.1.5INTEGERread-writemandatory
masterswitchVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5
sPDUIdentVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.1
sPDUIdentVMTableSize
OBJECT-TYPE
The number of MasterSwitch VMs controllable by this IP address.
1.3.6.1.4.1.318.1.1.5.1.1INTEGERread-onlymandatory
sPDUIdentVMTable
OBJECT-TYPE
Allows for query of the individual MasterSwitch VMs. The number of entries is contained in the sPDUIdentVMTableSize OID.
1.3.6.1.4.1.318.1.1.5.1.2not-accessiblemandatory
sPDUIdentVMEntry
OBJECT-TYPE
The MasterSwitch VMs to query.
1.3.6.1.4.1.318.1.1.5.1.2.1not-accessiblemandatory
sPDUIdentVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM entry.
1.3.6.1.4.1.318.1.1.5.1.2.1.1INTEGERread-onlymandatory
sPDUIdentNameVM
OBJECT-TYPE
A 23-character string identifying the MasterSwitch VM.
1.3.6.1.4.1.318.1.1.5.1.2.1.2DisplayStringread-onlymandatory
sPDUIdentHardwareRevVM
OBJECT-TYPE
The hardware version of the MasterSwitch VM. This value is set at the factory.
1.3.6.1.4.1.318.1.1.5.1.2.1.3DisplayStringread-onlymandatory
sPDUIdentFirmwareRevVM
OBJECT-TYPE
An 6-character ID string identifying the MasterSwitch VM firmware version. This value is set at the factory.
1.3.6.1.4.1.318.1.1.5.1.2.1.4DisplayStringread-onlymandatory
sPDUIdentDateOfManufactureVM
OBJECT-TYPE
The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.5.1.2.1.5DisplayStringread-onlymandatory
sPDUIdentModelNumberVM
OBJECT-TYPE
A 17-character string identifying the model number of the MasterSwitch VM. This value is set at the factory.
1.3.6.1.4.1.318.1.1.5.1.2.1.6DisplayStringread-onlymandatory
sPDUIdentSerialNumberVM
OBJECT-TYPE
A 17-character string identifying the serial number of the MasterSwitch VM. This value is set at the factory.
1.3.6.1.4.1.318.1.1.5.1.2.1.7DisplayStringread-onlymandatory
sPDUMasterControlVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.2
sPDUMasterControlVMTableSize
OBJECT-TYPE
The number of MasterSwitch VMs controllable by this IP address.
1.3.6.1.4.1.318.1.1.5.2.1INTEGERread-onlymandatory
sPDUMasterControlVMTable
OBJECT-TYPE
Allows for control of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterControlVMTableSize OID.
1.3.6.1.4.1.318.1.1.5.2.2not-accessiblemandatory
sPDUMasterControlVMEntry
OBJECT-TYPE
The MasterSwitch VMs to control.
1.3.6.1.4.1.318.1.1.5.2.2.1not-accessiblemandatory
sPDUMasterControlVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM entry.
1.3.6.1.4.1.318.1.1.5.2.2.1.1INTEGERread-onlymandatory
sPDUMasterControlVMName
OBJECT-TYPE
The name of the MasterSwitch VM. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigVMName OID.
1.3.6.1.4.1.318.1.1.5.2.2.1.2DisplayStringread-onlymandatory
sPDUMasterControlVMCommand
OBJECT-TYPE
Setting this OID to immediateAllOnVM (2) will turn all outlets on immediately. Setting this OID to immediateAllOffVM (3) will turn all outlets off immediately. Setting this OID to immediateAllRebootVM (4) will reboot all outlets immediately. Setting this OID to delayedAllOnVM (5) will turn all outlets on as defined by each outlet's sPDUOutletConfigVMPowerOnTime OID value. Setting this OID to delayedAllOffVM (6) will turn all outlets off as defined by each outlet's sPDUOutletConfigVMPowerOffTime OID value. Setting this OID to sequencedAllRebootVM (7) will cause a immediateAllOffVM command to be performed. The MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration OID time, and then perform a delayedAllOnVM command. Setting this OID to delayedAllRebootVM (8) will cause a delayedAllOffVM command to be performed. Each outlet will then wait its sPDUOutletConfigVMRebootDuration before returning power to the outlet. Setting this OID to delayedSequenceAllRebootVM (9) will cause a delayedAllOffVM command to be performed. Once all outlets are off, the MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration OID time, and then perform a delayedAllOnVM command. Setting this OID to cancelAllPendingCommandsVM (10) will cause all pending commands on the MasterSwitch VM to be canceled. Setting this OID to audioAlarmMute (11) will temporarily silence the audible alarm for the duration of the current overload condition. The audible alarm will be activated on subsequent overload alarms. Getting this OID will return the noCommandAllVM (1) value.
1.3.6.1.4.1.318.1.1.5.2.2.1.3INTEGER {noCommandAllVM(1), immediateAllOnVM(2), immediateAllOffVM(3), immediateAllRebootVM(4), delayedAllOnVM(5), delayedAllOffVM(6), sequencedAllRebootVM(7), delayedAllRebootVM(8), delayedSequenceAllRebootVM(9), cancelAllPendingCommandsVM(10), audioAlarmMute(11)}read-writemandatory
sPDUMasterConfigVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.3
sPDUMasterConfigVMTableSize
OBJECT-TYPE
The number of MasterSwitch VMs configurable by this IP address.
1.3.6.1.4.1.318.1.1.5.3.1INTEGERread-onlymandatory
sPDUMasterConfigVMTable
OBJECT-TYPE
Allows for configuration of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterConfigVMTableSize OID.
1.3.6.1.4.1.318.1.1.5.3.2not-accessiblemandatory
sPDUMasterConfigVMEntry
OBJECT-TYPE
The MasterSwitch VMs to configure.
1.3.6.1.4.1.318.1.1.5.3.2.1not-accessiblemandatory
sPDUMasterConfigVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM entry.
1.3.6.1.4.1.318.1.1.5.3.2.1.1INTEGERread-onlymandatory
sPDUMasterConfigVMName
OBJECT-TYPE
The name of the MasterSwitch VM. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.5.3.2.1.2DisplayStringread-writemandatory
sPDUMasterConfigVMColdstartDelay
OBJECT-TYPE
The amount of delay, in seconds, between when power is provided to the MasterSwitch VM and when the MasterSwitch VM provides basic master power to the outlets. Allowed values are: -1 never apply power automatically. 0 apply power immediately. 15 apply power in 15 seconds. 30 apply power in 30 seconds. 45 apply power in 45 seconds. 60 apply power in 60 seconds (1 minute). 120 apply power in 120 seconds (2 minutes). 300 apply power in 300 seconds (5 minutes). If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.5.3.2.1.3INTEGERread-writemandatory
sPDUMasterConfigVMAudioAlarmActivated
OBJECT-TYPE
Setting this OID to audioAlarmActiveNever (1) will disable the audio alarm on the MasterSwitch VM. Setting this OID to audioAlarmActiveOnOverload (2) will activate the audio alarm on the MasterSwitch VM when an overload condition is present. Setting this OID to audioAlarmActiveOnOverloadImminent (3) will activate the audio alarm on the MasterSwitch VM when the load on the MasterSwitch VM has surpassed the sPDUMasterConfigVMHighLoadWarningThreshold OID value.
1.3.6.1.4.1.318.1.1.5.3.2.1.4INTEGER {audioAlarmActiveNever(1), audioAlarmActiveOnOverload(2), audioAlarmActiveOnOverloadImminent(3)}read-writemandatory
sPDUMasterConfigVMHighLoadWarningThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented as a percentage of full load.
1.3.6.1.4.1.318.1.1.5.3.2.1.5INTEGER (0..100)read-writemandatory
sPDUMasterConfigVMLowLoadWarningThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented as a percentage of full load.
1.3.6.1.4.1.318.1.1.5.3.2.1.6INTEGER (0..100)read-writemandatory
sPDUMasterConfigVMOverloadRestriction
OBJECT-TYPE
This OID controls the behavior of the MasterSwitch VM when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets to turn on. Setting this OID to restrictOnWarning (2) will not allow outlets to turn on if the sPDUMasterConfigVMHighLoadWarningThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets to turn on if the MasterSwitch Vm is in an overload condition.
1.3.6.1.4.1.318.1.1.5.3.2.1.7INTEGER {alwaysAllowTurnON(1), restrictOnWarning(2), restrictOnOverload(3)}read-writemandatory
sPDUMasterStatusVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.4
sPDUMasterStatusVMTableSize
OBJECT-TYPE
The number of MasterSwitch VMs at this IP address.
1.3.6.1.4.1.318.1.1.5.4.1INTEGERread-onlymandatory
sPDUMasterStatusVMTable
OBJECT-TYPE
Allows for gathering of status from the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterStatusVMTableSize OID.
1.3.6.1.4.1.318.1.1.5.4.2not-accessiblemandatory
sPDUMasterStatusVMEntry
OBJECT-TYPE
The MasterSwitch VMs to gather status from.
1.3.6.1.4.1.318.1.1.5.4.2.1not-accessiblemandatory
sPDUMasterStatusVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM entry.
1.3.6.1.4.1.318.1.1.5.4.2.1.1INTEGERread-onlymandatory
sPDUMasterStatusVMName
OBJECT-TYPE
The name of the MasterSwitch VM. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.5.4.2.1.2DisplayStringread-onlymandatory
sPDUMasterStatusVMCommandPending
OBJECT-TYPE
Getting this OID will return commandPendingMasterTrueVM (1) if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2) will be returned if there are no pending commands.
1.3.6.1.4.1.318.1.1.5.4.2.1.3INTEGER {commandPendingMasterTrueVM(1), commandPendingMasterFalseVM(2)}read-onlymandatory
sPDUMasterStatusVMOverloadCondition
OBJECT-TYPE
Getting this OID will return overloadConditionTrueVM (1) if the sPDUMasterConfigVMHighLoadWarningThreshold OID is violated. overloadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarningThreshold OID is not violated.
1.3.6.1.4.1.318.1.1.5.4.2.1.4INTEGER {overloadConditionTrueVM(1), overloadConditionFalseVM(2)}read-onlymandatory
sPDUMasterStatusVMLowLoadCondition
OBJECT-TYPE
Getting this OID will return lowLoadConditionTrueVM (1) if the sPDUMasterConfigVMLowLoadWarningThreshold OID is violated. lowLoadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarningThreshold OID is not violated.
1.3.6.1.4.1.318.1.1.5.4.2.1.5INTEGER {lowLoadConditionTrueVM(1), lowLoadConditionFalseVM(2)}read-onlymandatory
sPDUMasterStatusVMCurrentLoad
OBJECT-TYPE
Getting this OID will return the total amount of power being consumed by the load. It is represented as a percentage of full load.
1.3.6.1.4.1.318.1.1.5.4.2.1.6INTEGERread-onlymandatory
sPDUMasterStatusVMMaxLoad
OBJECT-TYPE
Getting this OID will return the total amount of power that this MasterSwitch VM can provide. It is represented in Amps.
1.3.6.1.4.1.318.1.1.5.4.2.1.7INTEGERread-onlymandatory
sPDUMasterStatusVMOutletCount
OBJECT-TYPE
Getting this OID will return the number of controllable outlets for this MasterSwitch VM.
1.3.6.1.4.1.318.1.1.5.4.2.1.8INTEGERread-onlymandatory
sPDUMasterStatusVMRebootDuration
OBJECT-TYPE
Getting this OID will return the largest sPDUOutletConfigVMRebootDuration OID time for this MasterSwitch VM.
1.3.6.1.4.1.318.1.1.5.4.2.1.9INTEGERread-onlymandatory
sPDUOutletControlVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.5
sPDUOutletControlVMTable
OBJECT-TYPE
Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.5.5.1not-accessiblemandatory
sPDUOutletControlVMEntry
OBJECT-TYPE
The outlets to control.
1.3.6.1.4.1.318.1.1.5.5.1.1not-accessiblemandatory
sPDUOutletControlVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM.
1.3.6.1.4.1.318.1.1.5.5.1.1.1INTEGERread-onlymandatory
sPDUOutletControlVMName
OBJECT-TYPE
The name of the MasterSwitch VM. Maximum size is 23 characters. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.5.5.1.1.2DisplayStringread-onlymandatory
sPDUOutletControlVMOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.5.5.1.1.3INTEGERread-onlymandatory
sPDUOutletControlVMOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 23 characters. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.5.5.1.1.4DisplayStringread-onlymandatory
sPDUOutletControlVMOutletCommand
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the immediateOnVM (1) value will be returned. If the outlet is off, the immediateOffVM (2) value will be returned. Setting this variable to immediateOnVM (1) will immediately turn the outlet on. Setting this variable to immediateOffVM (2) will immediately turn the outlet off. Setting this variable to immediateRebootVM (3) will immediately reboot the outlet. Setting this variable to delayedOnVM (4) will turn the outlet on after the sPDUOutletConfigVMPowerOnTime OID time has elapsed. Setting this variable to delayedOffVM (5) will turn the outlet off after the sPDUOutletConfigVMPowerOffTime OID time has elapsed. Setting this variable to delayedRebootVM (6) will cause the MasterSwitch VM to perform a delayedOffVM command, wait the sPDUOutletConfigVMRebootDuration OID time, and then perform the immediateOnVM command. Setting this variable to cancelPendingCommandVM (7) will cause any pending command to this outlet to be canceled.
1.3.6.1.4.1.318.1.1.5.5.1.1.5INTEGER {immediateOnVM(1), immediateOffVM(2), immediateRebootVM(3), delayedOnVM(4), delayedOffVM(5), delayedRebootVM(6), cancelPendingCommandVM(7)}read-writemandatory
sPDUOutletConfigVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.6
sPDUOutletConfigVMTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.5.6.1not-accessiblemandatory
sPDUOutletConfigVMEntry
OBJECT-TYPE
The outlets to configure.
1.3.6.1.4.1.318.1.1.5.6.1.1not-accessiblemandatory
sPDUOutletConfigVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM.
1.3.6.1.4.1.318.1.1.5.6.1.1.1INTEGERread-onlymandatory
sPDUOutletConfigVMName
OBJECT-TYPE
The name of the MasterSwitch VM. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.5.6.1.1.2DisplayStringread-onlymandatory
sPDUOutletConfigVMOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.5.6.1.1.3INTEGERread-onlymandatory
sPDUOutletConfigVMOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.5.6.1.1.4DisplayStringread-writemandatory
sPDUOutletConfigVMPowerOnTime
OBJECT-TYPE
The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 never power on. 0 power on immediately. 15 power on 15 seconds after being commanded. 30 power on 30 seconds after being commanded. 45 power on 45 seconds after being commanded. 60 power on 60 seconds (1 minute) after being commanded. 120 power on 120 seconds (2 minutes) after being commanded. 300 power on 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.5.6.1.1.5INTEGERread-writemandatory
sPDUOutletConfigVMPowerOffTime
OBJECT-TYPE
The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 never power off automatically. 0 power off immediately. 15 power off 15 seconds after being commanded. 30 power off 30 seconds after being commanded. 45 power off 45 seconds after being commanded. 60 power off 60 seconds (1 minute) after being commanded. 120 power off 120 seconds (2 minutes) after being commanded. 300 power off 300 seconds (5 minutes) after being commanded. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.5.6.1.1.6INTEGERread-writemandatory
sPDUOutletConfigVMRebootDuration
OBJECT-TYPE
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed values are: 5 wait 5 seconds between off/on. 10 wait 10 seconds between off/on. 15 wait 15 seconds between off/on. 20 wait 20 seconds between off/on. 30 wait 30 seconds between off/on. 45 wait 45 seconds between off/on. 60 wait 60 seconds (1 minute) between off/on. If a value other than a supported value is provided in a set request, the MasterSwitch VM interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used.
1.3.6.1.4.1.318.1.1.5.6.1.1.7INTEGERread-writemandatory
sPDUOutletStatusVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.5.7
sPDUOutletStatusVMTable
OBJECT-TYPE
Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.5.7.1not-accessiblemandatory
sPDUOutletStatusVMEntry
OBJECT-TYPE
The outlets to gather status from.
1.3.6.1.4.1.318.1.1.5.7.1.1not-accessiblemandatory
sPDUOutletStatusVMIndex
OBJECT-TYPE
The index to the MasterSwitch VM.
1.3.6.1.4.1.318.1.1.5.7.1.1.1INTEGERread-onlymandatory
sPDUOutletStatusVMName
OBJECT-TYPE
The name of the MasterSwitch VM. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.5.7.1.1.2DisplayStringread-onlymandatory
sPDUOutletStatusVMOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.5.7.1.1.3INTEGERread-onlymandatory
sPDUOutletStatusVMOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.5.7.1.1.4DisplayStringread-onlymandatory
sPDUOutletStatusVMOutletState
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the outletStatusOnVM (1) value will be returned. If the outlet is off, the outletStatusOffVM (2) value will be returned.
1.3.6.1.4.1.318.1.1.5.7.1.1.5INTEGER {outletStatusVMOn(1), outletStatusVMOff(2)}read-onlymandatory
sPDUOutletStatusVMCommandPending
OBJECT-TYPE
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusVMCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusVMNoCommandPending (2) will be returned.
1.3.6.1.4.1.318.1.1.5.7.1.1.6INTEGER {outletStatusVMCommandPending(1), outletStatusVMNoCommandPending(2)}read-onlymandatory
masterswitchMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6
sPDUIdentMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.1
sPDUIdentMSPTableSize
OBJECT-TYPE
The number of MasterSwitch pluses controllable by this IP address.
1.3.6.1.4.1.318.1.1.6.1.1INTEGERread-onlymandatory
sPDUIdentMSPTable
OBJECT-TYPE
Allows for query of the individual MasterSwitch pluses. The number of entries is contained in the sPDUIdentMSPTableSize OID.
1.3.6.1.4.1.318.1.1.6.1.2not-accessiblemandatory
sPDUIdentMSPEntry
OBJECT-TYPE
The MasterSwitch pluses to query.
1.3.6.1.4.1.318.1.1.6.1.2.1not-accessiblemandatory
sPDUIdentMSPIndex
OBJECT-TYPE
The index to the MasterSwitch plus entry.
1.3.6.1.4.1.318.1.1.6.1.2.1.1INTEGERread-onlymandatory
sPDUIdentNameMSP
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.1.2.1.2DisplayStringread-onlymandatory
sPDUIdentHardwareRevMSP
OBJECT-TYPE
The hardware version of the MasterSwitch plus. This value is set at the factory.
1.3.6.1.4.1.318.1.1.6.1.2.1.3DisplayStringread-onlymandatory
sPDUIdentFirmwareRevMSP
OBJECT-TYPE
An 6-character ID string identifying the MasterSwitch plus firmware version. This value is set at the factory.
1.3.6.1.4.1.318.1.1.6.1.2.1.4DisplayStringread-onlymandatory
sPDUIdentDateOfManufactureMSP
OBJECT-TYPE
The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.6.1.2.1.5DisplayStringread-onlymandatory
sPDUIdentModelNumberMSP
OBJECT-TYPE
A 17-character string identifying the model number of the MasterSwitch plus. This value is set at the factory.
1.3.6.1.4.1.318.1.1.6.1.2.1.6DisplayStringread-onlymandatory
sPDUIdentSerialNumberMSP
OBJECT-TYPE
A 17-character string identifying the serial number of the MasterSwitch plus. This value is set at the factory.
1.3.6.1.4.1.318.1.1.6.1.2.1.7DisplayStringread-onlymandatory
sPDUMasterControlMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.2
sPDUMasterControlMSPTableSize
OBJECT-TYPE
The number of MasterSwitch pluses controllable by this IP address.
1.3.6.1.4.1.318.1.1.6.2.1INTEGERread-onlymandatory
sPDUMasterControlMSPTable
OBJECT-TYPE
Allows for control of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterControlMSPTableSize OID.
1.3.6.1.4.1.318.1.1.6.2.2not-accessiblemandatory
sPDUMasterControlMSPEntry
OBJECT-TYPE
The MasterSwitch pluses to control.
1.3.6.1.4.1.318.1.1.6.2.2.1not-accessiblemandatory
sPDUMasterControlMSPIndex
OBJECT-TYPE
The index to the MasterSwitch plus entry.
1.3.6.1.4.1.318.1.1.6.2.2.1.1INTEGERread-onlymandatory
sPDUMasterControlMSPName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.2.2.1.2DisplayStringread-onlymandatory
sPDUMasterControlMSPCommand
OBJECT-TYPE
Setting this OID to immediateAllOnMSP (2) will turn all outlets on immediately. Setting this OID to sequencedAllOnMSP (3) will turn all outlets on as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. Setting this OID to immediateAllOffMSP (4) will turn all outlets off immediately. Setting this OID to gracefulAllRebootMSP (5) will reboot all outlets (after the device running PowerChute confirms shutdown) as defined by each outlet's sPDUOutletConfigMSPRebootDuration OID time value. Setting this OID to immediateAllRebootMSP (6) will reboot all outlets immediately. Setting this OID to gracefulAllShutdownMSP (7) will shutdown all outlets (after the device running PowerChute confirms shutdown) as defined by each outlet's sPDUOutletConfigMSPPowerOffDelay OID time value. Each outlet will then turn on after the sum of its sPDUOutletConfigMSPRestartDelay and sPDUOutletConfigMSPPowerOnDelay OID values. Setting this OID to overrideAllBatCapThreshMSP (8) will cause the outlet to ignore the Battery Capacity Threshold and proceed turning on the outlets as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value. Setting this OID to cancelAllPendingCommandsMSP (9) will cause all pending commands on the MasterSwitch plus to be canceled. Setting this OID to restoreFactoryDefaultsMSP (10) will cause the settings of the MasterSwitch plus to be restored to the factory defaults. Getting this OID will return the noCommandAllMSP (1) value.
1.3.6.1.4.1.318.1.1.6.2.2.1.3INTEGER {noCommandAllMSP(1), immediateAllOnMSP(2), sequencedAllOnMSP(3), immediateAllOffMSP(4), gracefulAllRebootMSP(5), immediateAllRebootMSP(6), gracefulAllShutdownMSP(7), overrideAllBatCapThreshMSP(8), cancelAllPendingCommandsMSP(9), restoreFactoryDefaultsMSP(10)}read-writemandatory
sPDUMasterConfigMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.3
sPDUMasterConfigMSPTableSize
OBJECT-TYPE
The number of MasterSwitch pluses configurable by this IP address.
1.3.6.1.4.1.318.1.1.6.3.1INTEGERread-onlymandatory
sPDUMasterConfigMSPTable
OBJECT-TYPE
Allows for configuration of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterConfigMSPTableSize OID.
1.3.6.1.4.1.318.1.1.6.3.2not-accessiblemandatory
sPDUMasterConfigMSPEntry
OBJECT-TYPE
The MasterSwitch pluses to configure.
1.3.6.1.4.1.318.1.1.6.3.2.1not-accessiblemandatory
sPDUMasterConfigMSPIndex
OBJECT-TYPE
The index to the MasterSwitch plus entry.
1.3.6.1.4.1.318.1.1.6.3.2.1.1INTEGERread-onlymandatory
sPDUMasterConfigMSPName
OBJECT-TYPE
The name of the MasterSwitch plus. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.6.3.2.1.2DisplayStringread-writemandatory
sPDUMasterConfigMSPPowerOnTimeDelay
OBJECT-TYPE
The amount of delay, in seconds, between when power is provided to the MasterSwitch plus and when the MasterSwitch plus provides basic master power to the outlets. Allowed values are: 0 - 9999 seconds (0 - 2hrs, 46 mins, 39 secs). 0 indicates to apply power immediately.
1.3.6.1.4.1.318.1.1.6.3.2.1.3INTEGER (0..9999)read-writemandatory
sPDUMasterConfigMSPManualButton
OBJECT-TYPE
Setting this OID to manualButtonDisabled (1) will disable the manual button on the MasterSwitch plus. Setting this OID to manualButtonEnabled (2) will enable the manual button on the MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.3.2.1.4INTEGER {manualButtonDisabled(1), manualButtonEnabled(2)}read-writemandatory
sPDUMasterStatusMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.4
sPDUMasterStatusMSPTableSize
OBJECT-TYPE
The number of MasterSwitch pluses at this IP address.
1.3.6.1.4.1.318.1.1.6.4.1INTEGERread-onlymandatory
sPDUMasterStatusMSPTable
OBJECT-TYPE
Allows for gathering of status from the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterStatusMSPTableSize OID.
1.3.6.1.4.1.318.1.1.6.4.2not-accessiblemandatory
sPDUMasterStatusMSPEntry
OBJECT-TYPE
The MasterSwitch pluses to gather status from.
1.3.6.1.4.1.318.1.1.6.4.2.1not-accessiblemandatory
sPDUMasterStatusMSPIndex
OBJECT-TYPE
The index to the MasterSwitch plus entry.
1.3.6.1.4.1.318.1.1.6.4.2.1.1INTEGERread-onlymandatory
sPDUMasterStatusMSPName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.4.2.1.2DisplayStringread-onlymandatory
sPDUMasterStatusMSPOutletCount
OBJECT-TYPE
Getting this OID will return the number of controllable outlets for this MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.4.2.1.3INTEGERread-onlymandatory
sPDUOutletControlMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.5
sPDUOutletControlMSPTable
OBJECT-TYPE
Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
1.3.6.1.4.1.318.1.1.6.5.1not-accessiblemandatory
sPDUOutletControlMSPEntry
OBJECT-TYPE
The outlets to control.
1.3.6.1.4.1.318.1.1.6.5.1.1not-accessiblemandatory
sPDUOutletControlMSPIndex
OBJECT-TYPE
The index to the MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.5.1.1.1INTEGERread-onlymandatory
sPDUOutletControlMSPName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.5.1.1.2DisplayStringread-onlymandatory
sPDUOutletControlMSPOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.6.5.1.1.3INTEGERread-onlymandatory
sPDUOutletControlMSPOutletName
OBJECT-TYPE
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.5.1.1.4DisplayStringread-onlymandatory
sPDUOutletControlMSPOutletCommand
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the immediateOnMSP (1) value will be returned. If the outlet is off, the immediateOffMSP (3) value will be returned. Setting this variable to immediateOnMSP (1) will immediately turn the outlet on. Setting this variable to delayedOnMSP (2) will turn the outlet on after the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. Setting this variable to immediateOffMSP (3) will immediately turn the outlet off. Setting this variable to gracefulRebootMSP (4) will cause the outlet to wait for device confirmation (if applicable) and then turn the outlet off after the sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn on after the sPDUOutletConfigMSPRebootDuration OID time has elapsed. Setting this variable to immediateRebootMSP (5) will immediately reboot the outlet. Setting this variable to gracefulshutdownMSP (6) will cause the outlet to wait for device confirmation (if applicable) and then turn the outlet off after the sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn on after the sum of the sPDUOutletConfigMSPRestartTime OID time and the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed. Setting this variable to overrideBatCapThreshMSP (7) will cause the outlet to ignore the Battery Capacity Threshold and proceed waiting on the sPDUOutletConfigMSPPowerOnDelay OID time before turning the outlet on. Setting this variable to cancelPendingCommandMSP (8) will cause any pending command to this outlet to be canceled.
1.3.6.1.4.1.318.1.1.6.5.1.1.5INTEGER {immediateOnMSP(1), delayedOnMSP(2), immediateOffMSP(3), gracefulRebootMSP(4), immediateRebootMSP(5), gracefulshutdownMSP(6), overrideBatCapThreshMSP(7), cancelPendingCommandMSP(8)}read-writemandatory
sPDUOutletConfigMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.6
sPDUOutletConfigMSPall
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.6.1
sPDUOutletConfigMSPallTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
1.3.6.1.4.1.318.1.1.6.6.1.1not-accessiblemandatory
sPDUOutletConfigMSPallEntry
OBJECT-TYPE
The outlets to configure.
1.3.6.1.4.1.318.1.1.6.6.1.1.1not-accessiblemandatory
sPDUOutletConfigMSPallIndex
OBJECT-TYPE
The index to the MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.6.1.1.1.1INTEGERread-onlymandatory
sPDUOutletConfigMSPallName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.6.1.1.1.2DisplayStringread-onlymandatory
sPDUOutletConfigMSPallOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.6.6.1.1.1.3INTEGERread-onlymandatory
sPDUOutletConfigMSPallOutletName
OBJECT-TYPE
The name of the outlet. Maximum size is 23 characters.
1.3.6.1.4.1.318.1.1.6.6.1.1.1.4DisplayStringread-writemandatory
sPDUOutletConfigMSPallOutletCtrlMode
OBJECT-TYPE
Setting this OID to modeGracefulShutdown (1) will put this outlet into the Graceful Shutdown control mode. Setting this OID to modeAnnunciator (2) will put this outlet into the Annunciator control mode.
1.3.6.1.4.1.318.1.1.6.6.1.1.1.5INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)}read-writemandatory
sPDUOutletConfigMSPgs
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.6.2
sPDUOutletConfigMSPgsTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
1.3.6.1.4.1.318.1.1.6.6.2.1not-accessiblemandatory
sPDUOutletConfigMSPgsEntry
OBJECT-TYPE
The outlets to configure.
1.3.6.1.4.1.318.1.1.6.6.2.1.1not-accessiblemandatory
sPDUOutletConfigMSPgsIndex
OBJECT-TYPE
The index to the MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.1INTEGERread-onlymandatory
sPDUOutletConfigMSPgsName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.2DisplayStringread-onlymandatory
sPDUOutletConfigMSPgsOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.3INTEGERread-onlymandatory
sPDUOutletConfigMSPgsOutletName
OBJECT-TYPE
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.4DisplayStringread-onlymandatory
sPDUOutletConfigMSPgsOutletCtrlMode
OBJECT-TYPE
The Control Mode of the outlet. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.5INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)}read-onlymandatory
sPDUOutletConfigMSPgsDeviceConfirm
OBJECT-TYPE
Setting this OID to deviceConfirmNo (1) cause the outlet to NOT wait for device confirmation while performing graceful operations. Setting this OID to deviceConfirmYes (2) cause the outlet to wait for device confirmation while performing graceful operations.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.6INTEGER {deviceConfirmNo(1), deviceConfirmYes(2)}read-writemandatory
sPDUOutletConfigMSPgsLowBattWarning
OBJECT-TYPE
The amount of delay, in 6 second intervals, between when the UPS goes on battery and the power down sequence for the outlet is initiated. Allowed values are: -2 - Never initiate the power down sequence on low battery warning. -1 - Initiate power down sequence based on remaining runtime. 1 - 9999 six second intervals (6 secs - 16hrs, 39 mins, 54 secs). 0 indicates to immediately initiate power down sequence on low battery warning.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.7INTEGER (-2..9999)read-writemandatory
sPDUOutletConfigMSPgsLowBattMult
OBJECT-TYPE
Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is set to -1 (On Runtime Remaining). Allows you to set the value to stagger the shutdown sequence of the outlets. 1 provides the longest delay (the outlet to shutoff first), and 7 would provide the shortest delay (the outlet to shut off last). Allowed values are: 1 - 7.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.8INTEGER (1..7)read-writemandatory
sPDUOutletConfigMSPgsRestartDelay
OBJECT-TYPE
The amount of delay, in 6 minute intervals, between when the outlet is turned off and the outlet is turned back on when performing a Graceful Shutdown. Allowed values are: -1 - Never turn outlet back on after a Graceful shutdown. 0 - 9999 six minute intervals (0 - 999hrs, 54 mins).
1.3.6.1.4.1.318.1.1.6.6.2.1.1.9INTEGER (-1..9999)read-writemandatory
sPDUOutletConfigMSPgsPowerOnDelay
OBJECT-TYPE
The amount of delay, in seconds, between the UPS entering normal (on-line) state and the outlet being powered on. Allowed values are: -1 - Remain Off when the UPS enters the on-line state. 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
1.3.6.1.4.1.318.1.1.6.6.2.1.1.10INTEGER (-1..9999)read-writemandatory
sPDUOutletConfigMSPgsPowerOffDelay
OBJECT-TYPE
The amount of delay, in seconds, between when the server shuts down and the outlet is powered off. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
1.3.6.1.4.1.318.1.1.6.6.2.1.1.11INTEGER (0..9999)read-writemandatory
sPDUOutletConfigMSPgsBattCapThresh
OBJECT-TYPE
The minimum battery capacity, as a percent (0-100%), required of the UPS before an outlet will be allowed to power on. Allowed values are: 0 - 100 percent.
1.3.6.1.4.1.318.1.1.6.6.2.1.1.12INTEGER (0..100)read-writemandatory
sPDUOutletConfigMSPgsRebootDuration
OBJECT-TYPE
The amount of delay, in seconds, from outlet off until outlet on during a reboot. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
1.3.6.1.4.1.318.1.1.6.6.2.1.1.13INTEGER (0..9999)read-writemandatory
sPDUOutletConfigMSPannun
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.6.3
sPDUOutletConfigMSPannunTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
1.3.6.1.4.1.318.1.1.6.6.3.1not-accessiblemandatory
sPDUOutletConfigMSPannunEntry
OBJECT-TYPE
The outlets to configure.
1.3.6.1.4.1.318.1.1.6.6.3.1.1not-accessiblemandatory
sPDUOutletConfigMSPannunIndex
OBJECT-TYPE
The index to the MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.6.3.1.1.1INTEGERread-onlymandatory
sPDUOutletConfigMSPannunName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.6.3.1.1.2DisplayStringread-onlymandatory
sPDUOutletConfigMSPannunOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.6.6.3.1.1.3INTEGERread-onlymandatory
sPDUOutletConfigMSPannunOutletName
OBJECT-TYPE
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.6.3.1.1.4DisplayStringread-onlymandatory
sPDUOutletConfigMSPannunOutletCtrlMode
OBJECT-TYPE
The Control Mode of the outlet. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.6.3.1.1.5INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)}read-onlymandatory
sPDUOutletConfigMSPannunInitialState
OBJECT-TYPE
Setting this OID to initialStateOff (1) causes the outlet to default to off when in the non-alarmed condition. Setting this OID to initialStateOn (2) causes the outlet to default to on when in the non-alarmed condition.
1.3.6.1.4.1.318.1.1.6.6.3.1.1.6INTEGER {initialStateOff(1), initialStateOn(2)}read-writemandatory
sPDUOutletConfigMSPannunAlarmActionDly
OBJECT-TYPE
The amount of time, in seconds, that an enabled Measure-UPS alarm must be asserted before an alarm condition is recognized. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs).
1.3.6.1.4.1.318.1.1.6.6.3.1.1.7INTEGER (0..9999)read-writemandatory
sPDUOutletConfigMSPmups
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.6.4
sPDUOutletConfigMSPmupsTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
1.3.6.1.4.1.318.1.1.6.6.4.1not-accessiblemandatory
sPDUOutletConfigMSPmupsEntry
OBJECT-TYPE
The outlets to configure.
1.3.6.1.4.1.318.1.1.6.6.4.1.1not-accessiblemandatory
sPDUOutletConfigMSPmupsIndex
OBJECT-TYPE
The index to the MasterSwitch plus.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.1INTEGERread-onlymandatory
sPDUOutletConfigMSPmupsName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.2DisplayStringread-onlymandatory
sPDUOutletConfigMSPmupsOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.3INTEGERread-onlymandatory
sPDUOutletConfigMSPmupsOutletName
OBJECT-TYPE
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.4DisplayStringread-onlymandatory
sPDUOutletConfigMSPmupsZone1
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Zone 1 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 1 alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.5INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsZone2
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Zone 2 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 2 alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.6INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsZone3
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Zone 3 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 3 alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.7INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsZone4
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Zone 4 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 4 alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.8INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP1LowHum
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 1 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low humidity alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.9INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP1HiHum
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 1 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high humidity alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.10INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP1LowTemp
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 1 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low temperature alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.11INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP1HiTemp
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 1 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high temperature alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.12INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP2LowHum
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 2 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low humidity alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.13INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP2HiHum
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 2 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high humidity alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.14INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP2LowTemp
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 2 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low temperature alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.15INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletConfigMSPmupsP2HiTemp
OBJECT-TYPE
Setting this OID to disableAlarm (1) disables the Probe 2 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high temperature alarm for this outlet.
1.3.6.1.4.1.318.1.1.6.6.4.1.1.16INTEGER {disableAlarm(1), enableAlarm(2)}read-writemandatory
sPDUOutletStatusMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.6.7
sPDUOutletStatusMSPTable
OBJECT-TYPE
Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.6.7.1not-accessiblemandatory
sPDUOutletStatusMSPEntry
OBJECT-TYPE
The outlets to gather status from.
1.3.6.1.4.1.318.1.1.6.7.1.1not-accessiblemandatory
sPDUOutletStatusMSPIndex
OBJECT-TYPE
The index to the MasterSwitch MSP.
1.3.6.1.4.1.318.1.1.6.7.1.1.1INTEGERread-onlymandatory
sPDUOutletStatusMSPName
OBJECT-TYPE
The name of the MasterSwitch plus. The maximum value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID.
1.3.6.1.4.1.318.1.1.6.7.1.1.2DisplayStringread-onlymandatory
sPDUOutletStatusMSPOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.6.7.1.1.3INTEGERread-onlymandatory
sPDUOutletStatusMSPOutletName
OBJECT-TYPE
The name of the outlet. The maximum size is 23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.7.1.1.4DisplayStringread-onlymandatory
sPDUOutletStatusMSPOutletState
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the outletStatusMSPOn (1) value will be returned. If the outlet is off, the outletStatusMSPOff (2) value will be returned.
1.3.6.1.4.1.318.1.1.6.7.1.1.5INTEGER {outletStatusMSPOn(1), outletStatusMSPOff(2)}read-onlymandatory
sPDUOutletStatusMSPCommandPending
OBJECT-TYPE
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusMSPCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusMSPNoCommandPending (2) will be returned.
1.3.6.1.4.1.318.1.1.6.7.1.1.6INTEGER {outletStatusMSPCommandPending(1), outletStatusMSPNoCommandPending(2)}read-onlymandatory
sPDUOutletStatusMSPOutletCtrlMode
OBJECT-TYPE
The Control Mode of the outlet. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.6.7.1.1.7INTEGER {modeGracefulShutdown(1), modeAnnunciator(2)}read-onlymandatory
dcDM3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7
dm3Ident
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.1
dm3IdentSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.1.1
dm3IdentSysDescriptionTableSize
OBJECT-TYPE
The number of DC description records.
1.3.6.1.4.1.318.1.1.7.1.1.1INTEGERread-onlymandatory
dm3IdentSysDescriptionTable
OBJECT-TYPE
Allows for accessing description records of the powerplant. The number of entries is contained in the dm3IdentSysDescriptionTableSize OID.
1.3.6.1.4.1.318.1.1.7.1.1.2not-accessiblemandatory
dm3IdentSysDescriptionEntry
OBJECT-TYPE
The powerplant description record to reference.
1.3.6.1.4.1.318.1.1.7.1.1.2.1not-accessiblemandatory
dm3IdentSysDescriptionIndex
OBJECT-TYPE
The index to the DC powerplant description record.
1.3.6.1.4.1.318.1.1.7.1.1.2.1.1INTEGERread-onlymandatory
dm3IdentSysDescriptionText
OBJECT-TYPE
A 16 character text field describing the DC power plant device. This field can be configured from the dm3ConfigSysDescriptionText OID.
1.3.6.1.4.1.318.1.1.7.1.1.2.1.2DisplayStringread-onlymandatory
dm3IdentSysModel
OBJECT-TYPE
Model type of the DC power plant.
1.3.6.1.4.1.318.1.1.7.1.1.3INTEGERread-onlymandatory
dm3IdentSysCntrlRev
OBJECT-TYPE
Integer representation of the hardware revision of the Master Controller board.
1.3.6.1.4.1.318.1.1.7.1.1.4INTEGERread-onlymandatory
dm3IdentSysFWVersion
OBJECT-TYPE
Integer representation of the power plant Master Controller firmware revision.
1.3.6.1.4.1.318.1.1.7.1.1.5INTEGERread-onlymandatory
dm3Config
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2
dm3ConfigSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.1
dm3ConfigSysDescriptionTableSize
OBJECT-TYPE
The number of DC description records.
1.3.6.1.4.1.318.1.1.7.2.1.1INTEGERread-onlymandatory
dm3ConfigSysDescriptionTable
OBJECT-TYPE
Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTableSize OID.
1.3.6.1.4.1.318.1.1.7.2.1.2not-accessiblemandatory
dm3ConfigSysDescriptionEntry
OBJECT-TYPE
The powerplant description record to reference.
1.3.6.1.4.1.318.1.1.7.2.1.2.1not-accessiblemandatory
dm3ConfigSysDescriptionIndex
OBJECT-TYPE
The index to the DC powerplant description record.
1.3.6.1.4.1.318.1.1.7.2.1.2.1.1INTEGERread-onlymandatory
dm3ConfigSysDescriptionText
OBJECT-TYPE
16 character text field describing the DC power plant device.
1.3.6.1.4.1.318.1.1.7.2.1.2.1.2DisplayStringread-writemandatory
dm3ConfigSysHighTempThresh
OBJECT-TYPE
Ambient high temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.1.3INTEGERread-writemandatory
dm3ConfigSysHighTempAlarm
OBJECT-TYPE
For the System High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.1.4INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigSysLowTempThresh
OBJECT-TYPE
Ambient low temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.1.5INTEGERread-writemandatory
dm3ConfigSysLowTempAlarm
OBJECT-TYPE
For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.1.6INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigSysHardwareTempAlarm
OBJECT-TYPE
For the System Hardware Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.1.7INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigSysRemoteAccess
OBJECT-TYPE
This OID is used to disable remote write access to the power plant. Setting this OID to accessEnabled (1) will have no affect. Setting this OID to accessDisabled (2) will disable the ability to remotely configure the DC powerplant. Once remote access is disabled, it can only be restored from the front panel of the DC power plant.
1.3.6.1.4.1.318.1.1.7.2.1.8INTEGER {accessEnabled(1), accessDisabled(2)}read-writemandatory
dm3ConfigLVD
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.2
dm3ConfigLVDTableSize
OBJECT-TYPE
The number of DC powerplant LVDs controllable by this IP address.
1.3.6.1.4.1.318.1.1.7.2.2.1INTEGERread-onlymandatory
dm3ConfigLVDTable
OBJECT-TYPE
Allows for accessing settings of the LVDs. The number of entries is contained in the dm3ConfigLVDTableSize OID.
1.3.6.1.4.1.318.1.1.7.2.2.2not-accessiblemandatory
dm3ConfigLVDEntry
OBJECT-TYPE
The LVD to configure.
1.3.6.1.4.1.318.1.1.7.2.2.2.1not-accessiblemandatory
dm3ConfigLVDIndex
OBJECT-TYPE
The index to the DC powerplant LVD.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.1INTEGERread-onlymandatory
dm3ConfigLVDName
OBJECT-TYPE
The name of the LVD. The maximum value is 16 characters.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.2DisplayStringread-writemandatory
dm3ConfigLVDEnable
OBJECT-TYPE
This OID is used to control and indicate if the LVD is on or off. Setting this OID to enabledYes (1) will enable (turn on) the LVD. Setting this OID to enabledNo (2) will disable (turn off) the LVD.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.3INTEGER {enabledYes(1), enabledNo(2)}read-writemandatory
dm3ConfigLVDTripThresh
OBJECT-TYPE
LVD Trip threshold. If voltage exceeds threshold, the LVD will trip. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.4INTEGERread-writemandatory
dm3ConfigLVDResetThresh
OBJECT-TYPE
LVD Reset threshold. If voltage exceeds threshold, the LVD will reset. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.5INTEGERread-writemandatory
dm3ConfigLVDOpenAlarm
OBJECT-TYPE
For the LVD Open Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.6INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigLVDHWAlarm
OBJECT-TYPE
For the LVD Hardware Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.2.2.1.7INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.3
dm3ConfigBattFloatVolt
OBJECT-TYPE
Battery Float Voltage. This setting controls the power plant voltage. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.1INTEGERread-writemandatory
dm3ConfigBattMaxRecharge
OBJECT-TYPE
Battery Maximum Recharge Rate. This setting controls the battery max recharge rate. The value is based on C/20 for 240 AHr battery string. Values are represented in thousandths of Amps (mA). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.2INTEGERread-writemandatory
dm3ConfigBattDischargeThresh
OBJECT-TYPE
Battery discharge threshold. If battery output current exceeds threshold a battery discharge alarm will occur. Values are represented in thousandths of Amps (mA). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.3INTEGERread-writemandatory
dm3ConfigBattDischargeAlarm
OBJECT-TYPE
For the Battery Discharge Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.4INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattHighVoltThresh
OBJECT-TYPE
Battery high voltage threshold. If system battery voltage exceeds threshold a battery high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.5INTEGERread-writemandatory
dm3ConfigBattHighVoltAlarm
OBJECT-TYPE
For the Battery High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.6INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattLowVoltThresh
OBJECT-TYPE
Battery low voltage threshold. If system battery voltage is under threshold a battery low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.7INTEGERread-writemandatory
dm3ConfigBattLowVoltAlarm
OBJECT-TYPE
For the Battery Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.8INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattHighTempThresh
OBJECT-TYPE
Battery high temperature threshold. If system battery temperature exceeds threshold a battery high temperature alarm will occur. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.9INTEGERread-writemandatory
dm3ConfigBattHighTempAlarm
OBJECT-TYPE
For the Battery High Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.10INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattLowTempThresh
OBJECT-TYPE
Battery low temperature threshold. If system battery temperature is under threshold a battery low temperature alarm will occur. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.11INTEGERread-writemandatory
dm3ConfigBattLowTempAlarm
OBJECT-TYPE
For the Battery Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.12INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattAmpHour
OBJECT-TYPE
Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.13INTEGERread-writemandatory
dm3ConfigCompMethod
OBJECT-TYPE
This OID is used to configure and get the state of the battery temperature compensation. Setting this OID to tempcompOn (1) will enable/turn on the battery temperature compensation. Setting this OID to tempcompOff (2) will disable/turn off the battery temperature compensation.
1.3.6.1.4.1.318.1.1.7.2.3.14INTEGER {tempcompOn(1), tempcompOff(2)}read-writemandatory
dm3ConfigCompTempCoeff
OBJECT-TYPE
Compensation Temperature Coefficient. (uV/degC/cell). Units are presented in microvolts. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.15INTEGERread-writemandatory
dm3ConfigHighKneeTemp
OBJECT-TYPE
High Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.16INTEGERread-writemandatory
dm3ConfigLowKneeTemp
OBJECT-TYPE
Low Knee for temperature compensation: Compensation temperature coefficient becomes 0mV/degC/cell. Values are represented in thousandths of degrees Celsius. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.3.17INTEGERread-writemandatory
dm3ConfigBattHwCurrentAlarm
OBJECT-TYPE
For the Battery Current Hardware Alarm (indicating current is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.18INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigBattHwTempAlarm
OBJECT-TYPE
For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic limits, or a possible measurement fault; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.3.19INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigPowerModules
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4
dm3ConfigRectifier
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4.1
dm3ConfigRectThresh
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4.1.1
dm3ConfigRectHighVoltThresh
OBJECT-TYPE
Rectifier high voltage threshold. If rectifier voltage exceeds threshold a rectifier high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.1.1.1INTEGERread-writemandatory
dm3ConfigRectLowVoltThresh
OBJECT-TYPE
Rectifier low voltage threshold. If rectifier voltage is under threshold a rectifier low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.1.1.2INTEGERread-writemandatory
dm3ConfigRectFailSafe
OBJECT-TYPE
Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers to use in the event of communications loss with the Master Controller or Master Controller board failure. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.1.1.3INTEGERread-writemandatory
dm3ConfigRectFailComm
OBJECT-TYPE
Rectifier Communication Fail timeout. This OID represents the time interval in which there is no communication between the rectifier and the master controller at which the rectifier will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.1.1.4INTEGERread-writemandatory
dm3ConfigRectAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4.1.2
dm3ConfigRectHighVoltAlarm
OBJECT-TYPE
For the Rectifier High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.1INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigRectLowVoltAlarm
OBJECT-TYPE
For the Rectifier Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.2INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigRectConfigAlarm
OBJECT-TYPE
This alarm is activated when a new rectifier is detected; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.3INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigRect1ofNAlarm
OBJECT-TYPE
This setting indicates the action if ONE rectifier of a N+1 system has failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.4INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigRect2ofNAlarm
OBJECT-TYPE
This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.5INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigRectDiagAlarm
OBJECT-TYPE
For the Rectifier Controller Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.6INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigRectImbalanceAlarm
OBJECT-TYPE
For the Rectifier Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.7INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigRectCurrLimitAlarm
OBJECT-TYPE
For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.8INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigRectStandbyAlarm
OBJECT-TYPE
For the Rectifier Standby Alarm (indicating output DC has been turned off); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.9INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigRectFanFailAlarm
OBJECT-TYPE
For the Rectifier Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.10INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigRectFailAlarm
OBJECT-TYPE
For the Rectifier Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.11INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigRectHwVoltAlarm
OBJECT-TYPE
For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.1.2.12INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigConverter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4.2
dm3ConfigConvThresh
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4.2.1
dm3ConfigConvHighVoltThresh
OBJECT-TYPE
Converter high voltage threshold. If converter voltage exceeds threshold a converter high voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.1INTEGERread-writemandatory
dm3ConfigConvLowVoltThresh
OBJECT-TYPE
Converter low voltage threshold. If converter voltage exceeds threshold a converter low voltage alarm will occur. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.2INTEGERread-writemandatory
dm3ConfigConvFailSafe
OBJECT-TYPE
Converter Fail Safe point. This OID represents the value sent to converter controllers to use in the event of communications loss with the Master Controller or Master Controller board failure. Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.3INTEGERread-writemandatory
dm3ConfigConvSetPoint
OBJECT-TYPE
Converter Set point. This OID represents the initial set point used in the voltage control loop. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.4INTEGERread-writemandatory
dm3ConfigConvFailMax
OBJECT-TYPE
Converter Fail Maximum limit. This OID represents the value sent to the converter controllers to define the maximum set point allowed. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.5INTEGERread-writemandatory
dm3ConfigConvFailMin
OBJECT-TYPE
Converter Fail Minimum limit. This OID represents the value sent to the converter controllers to define the minimum set point allowed. Units are thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.6INTEGERread-writemandatory
dm3ConfigConvFailComm
OBJECT-TYPE
Converter Communication Fail timeout. This OID represents the time interval in which there is no communication between the converter and the master controller at which the converter will reset all its values to default. Values are represented in hundredths of Seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.4.2.1.7INTEGERread-writemandatory
dm3ConfigConvAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.4.2.2
dm3ConfigConvHighVoltAlarm
OBJECT-TYPE
For the Converter High Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.1INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigConvLowVoltAlarm
OBJECT-TYPE
For the Converter Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.2INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigConvConfigAlarm
OBJECT-TYPE
For the Converter Configuration Alarm (indicating a new converter has been detected); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.3INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigConv1ofNAlarm
OBJECT-TYPE
For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.4INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigConv2ofNAlarm
OBJECT-TYPE
For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.5INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigConvDiagAlarm
OBJECT-TYPE
For the Converter Diagnostics Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.6INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigConvImbalanceAlarm
OBJECT-TYPE
For the Converter Imbalance Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.7INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigConvCurrLimitAlarm
OBJECT-TYPE
For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.8INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigConvStandbyAlarm
OBJECT-TYPE
For the Converter Standby Alarm (indicating the converter is in the Standby state); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.9INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigConvFanFailAlarm
OBJECT-TYPE
For the Converter Fan Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.10INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigConvFailAlarm
OBJECT-TYPE
For the Converter Fail Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.11INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigConvHwVoltAlarm
OBJECT-TYPE
For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a possible measurement fault); Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system.
1.3.6.1.4.1.318.1.1.7.2.4.2.2.12INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9), alarmNofN(10)}read-writemandatory
dm3ConfigRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.5
dm3ConfigOutputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.5.1
dm3ConfigOutRlyTableSize
OBJECT-TYPE
The number of DC powerplant Output Relays controllable by this IP address.
1.3.6.1.4.1.318.1.1.7.2.5.1.1INTEGERread-onlymandatory
dm3ConfigOutRlyTable
OBJECT-TYPE
Allows for accessing settings of the Output Relays. The number of entries is contained in the dm3ConfigOutRlyTableSize OID.
1.3.6.1.4.1.318.1.1.7.2.5.1.2not-accessiblemandatory
dm3ConfigOutRlyEntry
OBJECT-TYPE
The output relay to configure.
1.3.6.1.4.1.318.1.1.7.2.5.1.2.1not-accessiblemandatory
dm3ConfigOutRlyIndex
OBJECT-TYPE
The index to the DC powerplant output relay.
1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.1INTEGERread-onlymandatory
dm3ConfigOutRlyName
OBJECT-TYPE
The name of the output relay. The maximum value is 16 characters.
1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.2DisplayStringread-writemandatory
dm3ConfigOutRlyDelay
OBJECT-TYPE
Output Relay Delay. This OID represents the time delay from the initiation of an output relay action to when the output relay action does occur. If the alarm condition disappears before the end of the delay, no action will occur. Delay for Major and Minor alarms is not configurable and is always set to 0. Values are represented in hundredths of seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.3INTEGERread-writemandatory
dm3ConfigOutRlyAlarm
OBJECT-TYPE
Output Relay Alarm. This setting indicates what action to perform in the event of an output relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition. Relay Alarm for Major and Minor alarms is not configurable and is always set to alarmMajor and alarmMinor respectively.
1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.4INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigInputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.5.2
dm3ConfigInRlyTableSize
OBJECT-TYPE
The number of DC powerplant Input Relays controllable by this IP address.
1.3.6.1.4.1.318.1.1.7.2.5.2.1INTEGERread-onlymandatory
dm3ConfigInRlyTable
OBJECT-TYPE
Allows for accessing settings of the Input Relays. The number of entries is contained in the dm3ConfigInRlyTableSize OID.
1.3.6.1.4.1.318.1.1.7.2.5.2.2not-accessiblemandatory
dm3ConfigInRlyEntry
OBJECT-TYPE
The input relay to configure.
1.3.6.1.4.1.318.1.1.7.2.5.2.2.1not-accessiblemandatory
dm3ConfigInRlyIndex
OBJECT-TYPE
The index to the DC powerplant input relay.
1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.1INTEGERread-onlymandatory
dm3ConfigInRlyName
OBJECT-TYPE
The name of the input relay. The maximum value is 16 characters.
1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.2DisplayStringread-writemandatory
dm3ConfigInRlyDelay
OBJECT-TYPE
Input Relay Delay. This OID represents the time delay from the initiation of an input relay action to when the input relay action does occur. If the alarm condition disappears before the end of the delay, no action will occur. Values are represented in hundredths of seconds. Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively.
1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.3INTEGERread-writemandatory
dm3ConfigInRlyAlarm
OBJECT-TYPE
Input Relay Alarm. This setting indicates what action to perform in the event of an input relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.4INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigDistribution
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.6
dm3ConfigBreakers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.6.1
dm3ConfigBreakersTableSize
OBJECT-TYPE
The number of DC powerplant circuit breakers controllable by this IP address.
1.3.6.1.4.1.318.1.1.7.2.6.1.1INTEGERread-onlymandatory
dm3ConfigBreakersTable
OBJECT-TYPE
Allows for accessing settings of the circuit breakers. The number of entries is contained in the dm3ConfigBreakersTableSize OID.
1.3.6.1.4.1.318.1.1.7.2.6.1.2not-accessiblemandatory
dm3ConfigBreakersEntry
OBJECT-TYPE
The circuit breaker to configure.
1.3.6.1.4.1.318.1.1.7.2.6.1.2.1not-accessiblemandatory
dm3ConfigBreakersIndex
OBJECT-TYPE
The index to the DC powerplant circuit breaker.
1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.1INTEGERread-onlymandatory
dm3ConfigBreakersName
OBJECT-TYPE
The name of the circuit breaker. The maximum value is 16 characters.
1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.2DisplayStringread-writemandatory
dm3ConfigBreakersAlarm
OBJECT-TYPE
Circuit Breaker Alarm. This setting indicates what action to perform in the event of a circuit breaker alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.3INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3ConfigFuses
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.2.6.2
dm3ConfigFusesTableSize
OBJECT-TYPE
The number of DC powerplant Fuses controllable by this IP address.
1.3.6.1.4.1.318.1.1.7.2.6.2.1INTEGERread-onlymandatory
dm3ConfigFusesTable
OBJECT-TYPE
Allows for accessing settings of the Fuses. The number of entries is contained in the dm3ConfigFusesTableSize OID.
1.3.6.1.4.1.318.1.1.7.2.6.2.2not-accessiblemandatory
dm3ConfigFusesEntry
OBJECT-TYPE
The fuse to configure.
1.3.6.1.4.1.318.1.1.7.2.6.2.2.1not-accessiblemandatory
dm3ConfigFusesIndex
OBJECT-TYPE
The index to the DC powerplant fuse.
1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.1INTEGERread-onlymandatory
dm3ConfigFusesName
OBJECT-TYPE
The name of the fuse. The maximum value is 16 characters.
1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.2DisplayStringread-writemandatory
dm3ConfigFusesAlarm
OBJECT-TYPE
Fuses Alarm. This setting indicates what action to perform in the event of a Fuse alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition.
1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.3INTEGER {alarmIgnore(1), alarmRelay1(2), alarmRelay2(3), alarmRelay3(4), alarmRelay4(5), alarmRelay5(6), alarmRelay6(7), alarmMinor(8), alarmMajor(9)}read-writemandatory
dm3Status
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3
dm3StatusSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.1
dm3StatusSystemTemp
OBJECT-TYPE
System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.7.3.1.1INTEGERread-onlymandatory
dm3StatusSystemStart
OBJECT-TYPE
Time stamp at DC powerplant initialization. The time is represented as MMM,DD,YYYY,HH:MM:SS.
1.3.6.1.4.1.318.1.1.7.3.1.2DisplayStringread-onlymandatory
dm3StatusSysRemoteAccess
OBJECT-TYPE
Remote Access indicator This setting indicates if configuration (write) access to the powerplant is enabled or disabled at the powerplant level. This value will be accessEnabled (1) if remote configuration is enabled, and accessDisabled (2) if remote configuration is disabled.
1.3.6.1.4.1.318.1.1.7.3.1.3INTEGER {accessEnabled(1), accessDisabled(2)}read-onlymandatory
dm3StatusSysSecurityLevel
OBJECT-TYPE
This variable shows the current active security access level of controller. This can only be changed directly from the front panel.
1.3.6.1.4.1.318.1.1.7.3.1.4INTEGERread-onlymandatory
dm3StatusSysTempSanity
OBJECT-TYPE
System temperature sanity indicator. Indicates if the system temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates temperature is reasonable, a value of saneNo (2) indicates it is not.
1.3.6.1.4.1.318.1.1.7.3.1.5INTEGER {saneYES(1), saneNO(2)}read-onlymandatory
dm3StatusSysAlarmState
OBJECT-TYPE
System Alarm State. Reflects the alarm status of the overall DC system. If a minor alarm is present, the value will be alarmMinor(1). If a major alarm is present, the value will be alarmMajor(2). If both minor and a major alarm is present, the value will be alarmBoth(3). If no alarm is present, the value will be alarmNone(4).
1.3.6.1.4.1.318.1.1.7.3.1.6INTEGER {alarmMinor(1), alarmMajor(2), alarmBoth(3), alarmNone(4)}read-onlymandatory
dm3StatusSysTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.7.3.1.7INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
dm3StatusAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.2
dm3StatusAlarmsTableSize
OBJECT-TYPE
The number of DC powerplant alarms viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.2.1INTEGERread-onlymandatory
dm3StatusAlarmsTable
OBJECT-TYPE
Allows for accessing system alarms. The number of entries is contained in the dm3StatusAlarmsTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.2.2not-accessiblemandatory
dm3StatusAlarmsEntry
OBJECT-TYPE
The alarm to display.
1.3.6.1.4.1.318.1.1.7.3.2.2.1not-accessiblemandatory
dm3StatusAlarmsIndex
OBJECT-TYPE
The index of the system alarm.
1.3.6.1.4.1.318.1.1.7.3.2.2.1.1INTEGERread-onlymandatory
dm3StatusAlarmsText
OBJECT-TYPE
The 16 character text describing the active alarm condition.
1.3.6.1.4.1.318.1.1.7.3.2.2.1.2DisplayStringread-onlymandatory
dm3StatusBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.3
dm3StatusBattCurrent
OBJECT-TYPE
Battery Current: This OID shows the battery current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.7.3.3.1INTEGERread-onlymandatory
dm3StatusBattTemp
OBJECT-TYPE
Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.7.3.3.2INTEGERread-onlymandatory
dm3StatusBattCurrentSanity
OBJECT-TYPE
Battery current sanity indicator. Indicates if the battery current is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates current is reasonable, a value of saneNo (2) indicates it is not.
1.3.6.1.4.1.318.1.1.7.3.3.3INTEGER {saneYES(1), saneNO(2)}read-onlymandatory
dm3StatusBattTempSanity
OBJECT-TYPE
Battery temperature sanity indicator. Indicates if the battery temperature is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates temperature is reasonable, a value of saneNo (2) indicates it is not.
1.3.6.1.4.1.318.1.1.7.3.3.4INTEGER {saneYES(1), saneNO(2)}read-onlymandatory
dm3StatusOEM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.4
dm3StatusOEMrectOffset
OBJECT-TYPE
This OID shows the rectifier offset value in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.7.3.4.1INTEGERread-onlymandatory
dm3StatusOEMrectGain
OBJECT-TYPE
This OID shows the rectifier gain value in thousandths of Volts (mV/V).
1.3.6.1.4.1.318.1.1.7.3.4.2INTEGERread-onlymandatory
dm3StatusOEMconvOffset
OBJECT-TYPE
This OID shows the converter offset value in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.7.3.4.3INTEGERread-onlymandatory
dm3StatusOEMconvGain
OBJECT-TYPE
This OID shows the converter gain value in thousandths of Volts (mV/V).
1.3.6.1.4.1.318.1.1.7.3.4.4INTEGERread-onlymandatory
dm3StatusOEMshuntOffset
OBJECT-TYPE
This OID shows the shunt offset value in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.7.3.4.5INTEGERread-onlymandatory
dm3StatusOEMshuntGain
OBJECT-TYPE
This OID shows the shunt gain value in thousandths of Amps (mA/A).
1.3.6.1.4.1.318.1.1.7.3.4.6INTEGERread-onlymandatory
dm3StatusLVD
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.5
dm3StatusLVDTableSize
OBJECT-TYPE
The number of DC powerplant LVDs viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.5.1INTEGERread-onlymandatory
dm3StatusLVDTable
OBJECT-TYPE
Allows for accessing settings of the LVDs. The number of entries is contained in the dm3StatusLVDTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.5.2not-accessiblemandatory
dm3StatusLVDEntry
OBJECT-TYPE
The LVD to gather status from.
1.3.6.1.4.1.318.1.1.7.3.5.2.1not-accessiblemandatory
dm3StatusLVDIndex
OBJECT-TYPE
The index to the DC powerplant LVD.
1.3.6.1.4.1.318.1.1.7.3.5.2.1.1INTEGERread-onlymandatory
dm3StatusLVDName
OBJECT-TYPE
The name of the LVD. The maximum size is 16 characters. The name is set by using the dm3ConfigLVDName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.7.3.5.2.1.2DisplayStringread-onlymandatory
dm3StatusLVDState
OBJECT-TYPE
Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened.
1.3.6.1.4.1.318.1.1.7.3.5.2.1.3INTEGER {statusClosed(1), statusOpened(2)}read-onlymandatory
dm3StatusLVDHwFault
OBJECT-TYPE
Getting this OID will return statusFault (1) if the LVD is faulted. statusNofault (2) will be returned if the LVD is not faulted.
1.3.6.1.4.1.318.1.1.7.3.5.2.1.4INTEGER {statusFault(1), statusNofault(2)}read-onlymandatory
dm3StatusPowerModules
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.6
dm3StatusRectifier
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.6.1
dm3StatusRectTableSize
OBJECT-TYPE
The number of DC powerplant rectifiers viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.6.1.1INTEGERread-onlymandatory
dm3StatusRectTable
OBJECT-TYPE
Allows for accessing settings of the rectifiers. The number of entries is contained in the dm3StatusRectTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.6.1.2not-accessiblemandatory
dm3StatusRectEntry
OBJECT-TYPE
The rectifier to gather status from.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1not-accessiblemandatory
dm3StatusRectIndex
OBJECT-TYPE
The index to the DC powerplant rectifier.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.1INTEGERread-onlymandatory
dm3StatusRectID
OBJECT-TYPE
This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.2INTEGERread-onlymandatory
dm3StatusRectDesc
OBJECT-TYPE
This OID shows the 16-character rectifier description.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.3DisplayStringread-onlymandatory
dm3StatusRectCurrent
OBJECT-TYPE
This OID shows the rectifier current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.4INTEGERread-onlymandatory
dm3StatusRectCurrentLimit
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state. statusFalse (2) will be returned if the rectifier is not in the Current Limit state.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.5INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectStandby
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier is in the Standby state. statusFalse (2) will be returned if the rectifier is not in the Standby state.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.6INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectFanFail
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier Fan has failed. statusFalse (2) will be returned if the rectifier Fan has not failed.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.7INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectFail
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.8INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectDevType
OBJECT-TYPE
This OID shows the rectifier device type.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.9INTEGERread-onlymandatory
dm3StatusRectPhyAddr
OBJECT-TYPE
This OID shows the rectifier physical address (the address on the bus).
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.10INTEGERread-onlymandatory
dm3StatusRectCfg
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier is present after power-up or set-configuration. statusFalse (2) will be returned if the rectifier is not configured.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.11INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectPcbRev
OBJECT-TYPE
This OID shows the rectifier device PCB serial number.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.12INTEGERread-onlymandatory
dm3StatusRectFwVer
OBJECT-TYPE
This OID shows the rectifier device firmware revision.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.13INTEGERread-onlymandatory
dm3StatusRectPresent
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier is present. statusFalse (2) will be returned if the rectifier is not present.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.14INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectDiagPass
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed. statusFalse (2) will be returned if the rectifier diagnostics have not passed.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.15INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusRectState
OBJECT-TYPE
This OID shows the rectifier device state as defined by the device status register.
1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.16INTEGERread-onlymandatory
dm3StatusSysRectVoltSanity
OBJECT-TYPE
Rectifier voltage sanity indicator. Indicates if the rectifier voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates voltage is reasonable, a value of saneNo (2) indicates it is not.
1.3.6.1.4.1.318.1.1.7.3.6.1.3INTEGER {saneYES(1), saneNO(2)}read-onlymandatory
dm3StatusSysRectAvailable
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier is available. statusFalse (2) will be returned if the rectifier is not available.
1.3.6.1.4.1.318.1.1.7.3.6.1.4INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusSysRectType
OBJECT-TYPE
This OID shows the type of rectifier the system has. There can only be a single type of rectifier in the power plant
1.3.6.1.4.1.318.1.1.7.3.6.1.5INTEGERread-onlymandatory
dm3StatusSysRectVoltage
OBJECT-TYPE
This OID shows the system level rectifier voltage in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.7.3.6.1.6INTEGERread-onlymandatory
dm3StatusSysRectCurrent
OBJECT-TYPE
This OID shows the system level rectifier current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.7.3.6.1.7INTEGERread-onlymandatory
dm3StatusConverter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.6.2
dm3StatusConvTableSize
OBJECT-TYPE
The number of DC powerplant converters viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.6.2.1INTEGERread-onlymandatory
dm3StatusConvTable
OBJECT-TYPE
Allows for viewing status of the converters. The number of entries is contained in the dm3StatusConvTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.6.2.2not-accessiblemandatory
dm3StatusConvEntry
OBJECT-TYPE
The converter to gather status from.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1not-accessiblemandatory
dm3StatusConvIndex
OBJECT-TYPE
The index to the DC powerplant converter.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.1INTEGERread-onlymandatory
dm3StatusConvID
OBJECT-TYPE
This OID shows the converter ID. This enumerates the number of the converter within a group of converters.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.2INTEGERread-onlymandatory
dm3StatusConvDesc
OBJECT-TYPE
This OID shows the 16 character converter description.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.3DisplayStringread-onlymandatory
dm3StatusConvCurrent
OBJECT-TYPE
This OID shows the converter current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.4INTEGERread-onlymandatory
dm3StatusConvCurrentLimit
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter is in the Current Limit state. statusFalse (2) will be returned if the converter is not in the Current Limit state.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.5INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvStandby
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter is in the Standby state. statusFalse (2) will be returned if the converter is not in the Standby state.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.6INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvFanFail
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter Fan has failed. statusFalse (2) will be returned if the converter Fan has not failed.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.7INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvFail
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter has failed. statusFalse (2) will be returned if the converter has not failed.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.8INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvDevType
OBJECT-TYPE
This OID shows the converter device type.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.9INTEGERread-onlymandatory
dm3StatusConvPhyAddr
OBJECT-TYPE
This OID shows the converter physical address (the address on the bus).
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.10INTEGERread-onlymandatory
dm3StatusConvCfg
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter is present after power-up or set-configuration. statusFalse (2) will be returned if the converter is not configured.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.11INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvPcbRev
OBJECT-TYPE
This OID shows the converter device PCB serial number.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.12INTEGERread-onlymandatory
dm3StatusConvFwVer
OBJECT-TYPE
This OID shows the converter device firmware version.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.13INTEGERread-onlymandatory
dm3StatusConvPresent
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter is present. statusFalse (2) will be returned if the converter is not present.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.14INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvDiagPass
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter diagnostics have passed. statusFalse (2) will be returned if the converter diagnostics have not passed.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.15INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusConvState
OBJECT-TYPE
This OID shows the converter state as defined by the device status register.
1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.16INTEGERread-onlymandatory
dm3StatusSysConvVoltSanity
OBJECT-TYPE
Converter voltage sanity indicator. Indicates if the converter voltage is reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1) indicates voltage is reasonable, a value of saneNo (2) indicates it is not.
1.3.6.1.4.1.318.1.1.7.3.6.2.3INTEGER {saneYES(1), saneNO(2)}read-onlymandatory
dm3StatusSysConvAvailable
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the converter is available. statusFalse (2) will be returned if the converter is not available.
1.3.6.1.4.1.318.1.1.7.3.6.2.4INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dm3StatusSysConvType
OBJECT-TYPE
This OID shows the converter type.
1.3.6.1.4.1.318.1.1.7.3.6.2.5INTEGERread-onlymandatory
dm3StatusSysConvVoltage
OBJECT-TYPE
This OID shows the system level converter voltage in thousandths of volts (mV).
1.3.6.1.4.1.318.1.1.7.3.6.2.6INTEGERread-onlymandatory
dm3StatusSysConvCurrent
OBJECT-TYPE
This OID shows the system level converter current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.7.3.6.2.7INTEGERread-onlymandatory
dm3StatusRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.7
dm3StatusOutputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.7.1
dm3StatusOutRlyTableSize
OBJECT-TYPE
The number of DC powerplant output relays viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.7.1.1INTEGERread-onlymandatory
dm3StatusOutRlyTable
OBJECT-TYPE
Allows for viewing status of the output relays. The number of entries is contained in the dm3StatusOutRlyTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.7.1.2not-accessiblemandatory
dm3StatusOutRlyEntry
OBJECT-TYPE
The output relay to gather status from.
1.3.6.1.4.1.318.1.1.7.3.7.1.2.1not-accessiblemandatory
dm3StatusOutRlyIndex
OBJECT-TYPE
The index to the DC powerplant output relay.
1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.1INTEGERread-onlymandatory
dm3StatusOutRlyName
OBJECT-TYPE
The name of the output relay. The maximum size is 16 characters. The name is set by using the dm3ConfigOutRlyName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.2DisplayStringread-onlymandatory
dm3StatusOutRlyStatus
OBJECT-TYPE
Getting this OID will return statusOn (1) if the output relay is enabled/on. statusOff (2) will be returned if the output relay is disabled/off.
1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.3INTEGER {statusOn(1), statusOff(2)}read-onlymandatory
dm3StatusInputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.7.2
dm3StatusInRlyTableSize
OBJECT-TYPE
The number of DC powerplant input relays viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.7.2.1INTEGERread-onlymandatory
dm3StatusInRlyTable
OBJECT-TYPE
Allows for viewing status of the input relays. The number of entries is contained in the dm3StatusInRlyTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.7.2.2not-accessiblemandatory
dm3StatusInRlyEntry
OBJECT-TYPE
The input relays to gather status from.
1.3.6.1.4.1.318.1.1.7.3.7.2.2.1not-accessiblemandatory
dm3StatusInRlyIndex
OBJECT-TYPE
The index to the DC powerplant input relay.
1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.1INTEGERread-onlymandatory
dm3StatusInRlyName
OBJECT-TYPE
The name of the input relay. The maximum size is 16 characters. The name is set by using the dm3ConfigInRlyName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.2DisplayStringread-onlymandatory
dm3StatusInRlyStatus
OBJECT-TYPE
Getting this OID will return statusOn (1) if the input relay is enabled/on. statusOff (2) will be returned if the input relay is disabled/off.
1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.3INTEGER {statusOn(1), statusOff(2)}read-onlymandatory
dm3StatusDistribution
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.8
dm3StatusBreakers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.8.1
dm3StatusBreakersTableSize
OBJECT-TYPE
The number of DC powerplant circuit breakers viewable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.8.1.1INTEGERread-onlymandatory
dm3StatusBreakersTable
OBJECT-TYPE
Allows for viewing status of the circuit breakers. The number of entries is contained in the dm3StatusBreakersTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.8.1.2not-accessiblemandatory
dm3StatusBreakersEntry
OBJECT-TYPE
The circuit breaker to gather status from.
1.3.6.1.4.1.318.1.1.7.3.8.1.2.1not-accessiblemandatory
dm3StatusBreakersIndex
OBJECT-TYPE
The index to the DC powerplant circuit breaker.
1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.1INTEGERread-onlymandatory
dm3StatusBreakersName
OBJECT-TYPE
The name of the circuit breaker. The maximum size is 16 characters. The name is set by using the dm3ConfigBreakersName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.2DisplayStringread-onlymandatory
dm3StatusBreakersStatus
OBJECT-TYPE
Getting this OID will return statusClosed (1) if the circuit breaker is closed. statusOpen (2) will be returned if the circuit breaker is open.
1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.3INTEGER {statusClosed(1), statusOpen(2)}read-onlymandatory
dm3StatusFuses
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.7.3.8.2
dm3StatusFusesTableSize
OBJECT-TYPE
The number of DC powerplant fuses controllable by this IP address.
1.3.6.1.4.1.318.1.1.7.3.8.2.1INTEGERread-onlymandatory
dm3StatusFusesTable
OBJECT-TYPE
Allows for viewing status of the fuses. The number of entries is contained in the dm3StatusFusesTableSize OID.
1.3.6.1.4.1.318.1.1.7.3.8.2.2not-accessiblemandatory
dm3StatusFusesEntry
OBJECT-TYPE
The fuse to gather status from.
1.3.6.1.4.1.318.1.1.7.3.8.2.2.1not-accessiblemandatory
dm3StatusFusesIndex
OBJECT-TYPE
The index to the DC powerplant fuse.
1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.1INTEGERread-onlymandatory
dm3StatusFusesName
OBJECT-TYPE
The name of the fuse. The maximum size is 16 characters. The name is set by using the dm3ConfigFuseName OID. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.2DisplayStringread-onlymandatory
dm3StatusFusesStatus
OBJECT-TYPE
Getting this OID will return statusClosed (1) if the fuse is closed. statusOpen (2) will be returned if the fuse is open.
1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.3INTEGER {statusClosed(1), statusOpen(2)}read-onlymandatory
automaticTransferSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8
atsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.1
atsIdentHardwareRev
OBJECT-TYPE
The hardware revision of the Automatic Transfer Switch. This value is set at the factory.
1.3.6.1.4.1.318.1.1.8.1.1DisplayStringread-onlymandatory
atsIdentFirmwareRev
OBJECT-TYPE
A string identifying the Automatic Transfer Switch firmware revision.
1.3.6.1.4.1.318.1.1.8.1.2DisplayStringread-onlymandatory
atsIdentFirmwareDate
OBJECT-TYPE
The date of release for this Automatic Transfer Switch firmware revision.
1.3.6.1.4.1.318.1.1.8.1.3DisplayStringread-onlymandatory
atsIdentDateOfManufacture
OBJECT-TYPE
The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.8.1.4DisplayStringread-onlymandatory
atsIdentModelNumber
OBJECT-TYPE
A string identifying the model number of the Automatic Transfer Switch. This value is set at the factory.
1.3.6.1.4.1.318.1.1.8.1.5DisplayStringread-onlymandatory
atsIdentSerialNumber
OBJECT-TYPE
A string identifying the serial number of the Automatic Transfer Switch. This value is set at the factory.
1.3.6.1.4.1.318.1.1.8.1.6DisplayStringread-onlymandatory
atsIdentNominalLineVoltage
OBJECT-TYPE
RMS Utility Voltage measured in Volts.
1.3.6.1.4.1.318.1.1.8.1.7INTEGERread-onlymandatory
atsIdentNominalLineFrequency
OBJECT-TYPE
Utility Power Frequency measured in Hertz.
1.3.6.1.4.1.318.1.1.8.1.8INTEGERread-onlymandatory
atsIdentDeviceRating
OBJECT-TYPE
This gives the device rating in Amps
1.3.6.1.4.1.318.1.1.8.1.9INTEGERread-onlymandatory
atsCalibration
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.2
atsCalibrationInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.2.1
atsCalibrationNumInputs
OBJECT-TYPE
The number of inputs to this device.
1.3.6.1.4.1.318.1.1.8.2.1.1INTEGERread-onlymandatory
atsCalibrationNumInputPhases
OBJECT-TYPE
The number of phases per input for this device.
1.3.6.1.4.1.318.1.1.8.2.1.2INTEGERread-onlymandatory
atsCalibrationInputPhaseTable
OBJECT-TYPE
The number of phases per input line to this device.
1.3.6.1.4.1.318.1.1.8.2.1.3not-accessiblemandatory
atsCalibrationInputPhaseEntry
OBJECT-TYPE
An entry containing calibration information applicable to a particular input phase.
1.3.6.1.4.1.318.1.1.8.2.1.3.1not-accessiblemandatory
atsCalibrationInputTableIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.8.2.1.3.1.1INTEGERread-onlymandatory
atsCalibrationInputPhaseTableIndex
OBJECT-TYPE
The input phase identifier.
1.3.6.1.4.1.318.1.1.8.2.1.3.1.2INTEGERread-onlymandatory
atsLineVoltageCalibrationFactor
OBJECT-TYPE
The Line Voltage Calibration factor. This value is set at the factory.
1.3.6.1.4.1.318.1.1.8.2.1.3.1.3INTEGERread-onlymandatory
atsCalibrationPowerSupply
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.2.2
atsCalibrationPowerSupplyVoltages
OBJECT-TYPE
The number of power supply voltages supported by this device. This variable indicates the number of rows in the atsCalibrationPowerSupplyTable.
1.3.6.1.4.1.318.1.1.8.2.2.1INTEGERread-onlymandatory
atsCalibrationPowerSupplyVoltageTable
OBJECT-TYPE
A list of Power Supply table entries.
1.3.6.1.4.1.318.1.1.8.2.2.2not-accessiblemandatory
atsCalibrationPowerSupplyVoltageEntry
OBJECT-TYPE
An entry containing information applicable to a particular Power Supply Voltage.
1.3.6.1.4.1.318.1.1.8.2.2.2.1not-accessiblemandatory
atsCalibrationPowerSupplyVoltageTableIndex
OBJECT-TYPE
The power supply voltage identifier.
1.3.6.1.4.1.318.1.1.8.2.2.2.1.1INTEGERread-onlymandatory
atsCalibrationPowerSupplyVoltage
OBJECT-TYPE
This value describes the power supply voltage of 24V Source A, 24V Source B, +12V, -12V and 5V.
1.3.6.1.4.1.318.1.1.8.2.2.2.1.2INTEGER {powerSupply24V(1), powerSupply12V(2), powerSupply(3), powerSupply24VSourceB(4), powerSupplyMinus12V(5)}read-onlymandatory
atsPowerSupplyVoltageCalibrationFactor
OBJECT-TYPE
The Line Voltage Calibration factor. This value is set at the factory.
1.3.6.1.4.1.318.1.1.8.2.2.2.1.3INTEGERread-onlymandatory
ats4gCalibrationPowerSupplyVoltageTable
OBJECT-TYPE
A list of Power Supply table entries. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.2.3not-accessiblemandatory
ats4gCalibrationPowerSupplyVoltageEntry
OBJECT-TYPE
An entry containing information applicable to a particular Power Supply Voltage. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.2.3.1not-accessiblemandatory
ats4gCalibrationPowerSupplyVoltageTableIndex
OBJECT-TYPE
The power supply voltage identifier. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.2.3.1.1INTEGERread-onlymandatory
ats4gCalibrationPowerSupplyVoltage
OBJECT-TYPE
This value describes the power supply voltage of 24V Source A, 24V Source B, VBoost Source A, VBoost Source B, 3.3V, 1.0V. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.2.3.1.2INTEGER {powerSupply24VA(1), powerSupply24VB(2), powerSupplyVBoostA(3), powerSupplyVBoostB(4), powerSupply3Dot3V(5), powerSupply1Dot0V(6)}read-onlymandatory
ats4gPowerSupplyVoltageCalibrationFactor
OBJECT-TYPE
The Line Voltage Calibration factor. This value is set at the factory. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.2.3.1.3INTEGERread-onlymandatory
atsCalibrationOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.2.3
atsCalibrationNumOutputs
OBJECT-TYPE
The number of output lines from this device. This variable indicates the number of rows in the atsCalibrationOutputTable.
1.3.6.1.4.1.318.1.1.8.2.3.1INTEGERread-onlymandatory
atsCalibrationNumOutputPhases
OBJECT-TYPE
The number of output phases utilized in this device.
1.3.6.1.4.1.318.1.1.8.2.3.2INTEGERread-onlymandatory
atsCalibrationOutputTable
OBJECT-TYPE
A list of output table entries.
1.3.6.1.4.1.318.1.1.8.2.3.3not-accessiblemandatory
atsCalibrationOutputEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.8.2.3.3.1not-accessiblemandatory
atsCalibrationOutputTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.8.2.3.3.1.1INTEGERread-onlymandatory
atsCalibrationOutputPhasesTableIndex
OBJECT-TYPE
Description of each calibration factor for each output phase utilized in this device and one for neutral.
1.3.6.1.4.1.318.1.1.8.2.3.3.1.2INTEGER {phase1(1), phase2(2), phase3(3), neutral(4)}read-onlymandatory
atsOutputCurrentCalibrationFactor
OBJECT-TYPE
The output current calibration factor measured in Amps.
1.3.6.1.4.1.318.1.1.8.2.3.3.1.3INTEGERread-onlymandatory
ats4gCalibrationOutputTable
OBJECT-TYPE
A list of output table entries. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.3.4not-accessiblemandatory
ats4gCalibrationOutputEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.8.2.3.4.1not-accessiblemandatory
ats4gCalibrationOutputTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.8.2.3.4.1.1INTEGERread-onlymandatory
ats4gCalibrationOutputPhasesTableIndex
OBJECT-TYPE
Description of each calibration factor for each output phase utilized in this device and one for neutral. Bank 1 and Bank 2 are for units with two circuit breakers. It is not applicable to AP77xx ATS units.
1.3.6.1.4.1.318.1.1.8.2.3.4.1.2INTEGER {sourceALine(1), sourneBLine(2), bank1(3), bank2(4)}read-onlymandatory
ats4gOutputCurrentCalibrationFactor
OBJECT-TYPE
The output current calibration factor measured in Amps. It is not applicable to AP7xxx ATS units.
1.3.6.1.4.1.318.1.1.8.2.3.4.1.3INTEGERread-onlymandatory
atsControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.3
atsControlResetATS
OBJECT-TYPE
Setting this variable will cause the Automatic Transfer Switch to perform a power-on reset. It is not applicable to AP44xx units.
1.3.6.1.4.1.318.1.1.8.3.1INTEGER {none(1), reset(2)}read-writemandatory
atsControlClearAllAlarms
OBJECT-TYPE
Setting this variable will clear all alarms in the Automatic Transfer Switch. Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.3.2INTEGER {none(1), clear(2)}read-writemandatory
atsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.4
atsConfigProductName
OBJECT-TYPE
A configurable character string.
1.3.6.1.4.1.318.1.1.8.4.1DisplayStringread-writemandatory
atsConfigPreferredSource
OBJECT-TYPE
This variable returns the preferred source of power when both sources are OK.
1.3.6.1.4.1.318.1.1.8.4.2INTEGER {sourceA(1), sourceB(2), none(3)}read-writemandatory
atsConfigFrontPanelLockout
OBJECT-TYPE
Setting this variable to disableFrontPanel(1), prevents source preference configuration of the Automatic Transfer Switch via the Front Panel. Setting this variable to enableFrontPanel(2)allows, source preference configuration of the Automatic Transfer Switch via the Front Panel.
1.3.6.1.4.1.318.1.1.8.4.3INTEGER {disableFrontPanel(1), enableFrontPanel(2)}read-writemandatory
atsConfigVoltageSensitivity
OBJECT-TYPE
This variable defines the sensitivity to changes in voltage: high(1) for best protection, low(2) for frequent small line voltage changes.
1.3.6.1.4.1.318.1.1.8.4.4INTEGER {high(1), low(2)}read-writemandatory
atsConfigTransferVoltageRange
OBJECT-TYPE
This variable defines the range of acceptable voltage from a power source. If the voltage measured from the selected input source is not within this range, the Automatic Transfer Switch will switch over (transfer) to the alternate power source.
1.3.6.1.4.1.318.1.1.8.4.5INTEGER {wide(1), medium(2), narrow(3)}read-writemandatory
atsConfigCurrentLimit
OBJECT-TYPE
The threshold (in Amps) at which an Over Current Alarm will be generated. This OID returns the overload threshold value of the OID atsConfigPhaseOverLoadThreshold for the 1U ATS and OID atsConfigBankOverLoadThreshold of total for the 2U ATS. Setting this OID does not have any impact on the device.
1.3.6.1.4.1.318.1.1.8.4.6INTEGER (0..20)read-writemandatory
atsConfigResetValues
OBJECT-TYPE
Resets the ATS configuration to its default values. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.8.4.7INTEGER {none(1), reset(2)}read-writemandatory
atsConfigLineVRMS
OBJECT-TYPE
To configure the input RMS voltage.
1.3.6.1.4.1.318.1.1.8.4.8INTEGERread-writemandatory
atsConfigLineVRMSNarrowLimit
OBJECT-TYPE
To configure the Line VRMS Narrow Limit.
1.3.6.1.4.1.318.1.1.8.4.9INTEGERread-writemandatory
atsConfigLineVRMSMediumLimit
OBJECT-TYPE
To configure the Line VRMS Medium Limit.
1.3.6.1.4.1.318.1.1.8.4.10INTEGERread-writemandatory
atsConfigLineVRMSWideLimit
OBJECT-TYPE
To configure the Line VRMS Wide Limit.
1.3.6.1.4.1.318.1.1.8.4.11INTEGERread-writemandatory
atsConfigFrequencyDeviation
OBJECT-TYPE
To configure the frequency deviation. AP77xx units uses the options of 1, 2, or 3. AP44xx units uses the options of 3, 5, or 10.
1.3.6.1.4.1.318.1.1.8.4.12INTEGER {one(1), two(2), three(3), five(5), ten(10)}read-writemandatory
atsConfigBankTableSize
OBJECT-TYPE
The size of the bank table.
1.3.6.1.4.1.318.1.1.8.4.13INTEGERread-onlymandatory
atsConfigBankTable
OBJECT-TYPE
Allows for configuration of each ATS bank.
1.3.6.1.4.1.318.1.1.8.4.14not-accessiblemandatory
atsConfigBankEntry
OBJECT-TYPE
This gives access to bank current threshold
1.3.6.1.4.1.318.1.1.8.4.14.1not-accessiblemandatory
atsConfigBankTableIndex
OBJECT-TYPE
An index to the bank table entry.
1.3.6.1.4.1.318.1.1.8.4.14.1.1INTEGERread-onlymandatory
atsConfigBank
OBJECT-TYPE
The bank number of an ATS
1.3.6.1.4.1.318.1.1.8.4.14.1.2INTEGER {total(1), bank1(2), bank2(3)}read-onlymandatory
atsConfigBankLowLoadThreshold
OBJECT-TYPE
A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps disables this warning. Maximum value must be less than the value returned by the atsConfigBankNearOverLoadThreshold OID.
1.3.6.1.4.1.318.1.1.8.4.14.1.3INTEGERread-writemandatory
atsConfigBankNearOverLoadThreshold
OBJECT-TYPE
A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the atsConfigBankLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the atsConfigBankOverLoadThreshold OID.
1.3.6.1.4.1.318.1.1.8.4.14.1.4INTEGERread-writemandatory
atsConfigBankOverLoadThreshold
OBJECT-TYPE
A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the atsConfigBankNearOverLoadThreshold OID. Maximum value must be less than or equal to the value returned by atsIdentDeviceRating OID.
1.3.6.1.4.1.318.1.1.8.4.14.1.5INTEGERread-writemandatory
atsConfigPhaseTableSize
OBJECT-TYPE
The size of the phase table.
1.3.6.1.4.1.318.1.1.8.4.15INTEGERread-onlymandatory
atsConfigPhaseTable
OBJECT-TYPE
Allows for configuration of each ATS phase.
1.3.6.1.4.1.318.1.1.8.4.16not-accessiblemandatory
atsConfigPhaseEntry
OBJECT-TYPE
This gives access to phase threshold
1.3.6.1.4.1.318.1.1.8.4.16.1not-accessiblemandatory
atsConfigPhaseTableIndex
OBJECT-TYPE
The index to the phase table entry.
1.3.6.1.4.1.318.1.1.8.4.16.1.1INTEGERread-onlymandatory
atsConfigPhase
OBJECT-TYPE
The phase number of an ATS
1.3.6.1.4.1.318.1.1.8.4.16.1.2INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
atsConfigPhaseLowLoadThreshold
OBJECT-TYPE
A threshold that indicates the current drawn is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps disables this warning. Maximum value must be less than the value returned by the atsConfigPhaseNearOverLoadThreshold OID.
1.3.6.1.4.1.318.1.1.8.4.16.1.3INTEGERread-writemandatory
atsConfigPhaseNearOverLoadThreshold
OBJECT-TYPE
A threshold that indicates the current drawn is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the atsConfigPhaseLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the atsConfigPhaseOverLoadThreshold OID.
1.3.6.1.4.1.318.1.1.8.4.16.1.4INTEGERread-writemandatory
atsConfigPhaseOverLoadThreshold
OBJECT-TYPE
A threshold that indicates the current drawn has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the atsConfigPhaseNearOverLoadThreshold OID. Maximum value must be less than or equal to the value returned by atsIdentDeviceRating OID.
1.3.6.1.4.1.318.1.1.8.4.16.1.5INTEGERread-writemandatory
atsStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.5
atsStatusDeviceStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.5.1
atsStatusCommStatus
OBJECT-TYPE
This variable returns the current communication status of the Automatic Transfer Switch.
1.3.6.1.4.1.318.1.1.8.5.1.1INTEGER {atsNeverDiscovered(1), atsCommEstablished(2), atsCommLost(3)}read-onlymandatory
atsStatusSelectedSource
OBJECT-TYPE
This variable returns the current source of power.
1.3.6.1.4.1.318.1.1.8.5.1.2INTEGER {sourceA(1), sourceB(2)}read-onlymandatory
atsStatusRedundancyState
OBJECT-TYPE
This variable returns the current redundancy state of the ATS. atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power source if the current source fails. atsFullyRedundant(2) indicates that the ATS will switch over to the alternate power source if the current source fails.
1.3.6.1.4.1.318.1.1.8.5.1.3INTEGER {atsRedundancyLost(1), atsFullyRedundant(2)}read-onlymandatory
atsStatusOverCurrentState
OBJECT-TYPE
This variable returns the output current state of the ATS. atsOverCurrent(1) indicates that the ATS has exceeded the output current threshold and will not allow a switch over to the alternate power source if the current source fails. atsCurrentOK(2) indicates that the output current is below the output current threshold. This OID returns the value of the OID atsOutputPhaseState for the 1U ATS and OID atsOutputBankState for the 2U ATS.
1.3.6.1.4.1.318.1.1.8.5.1.4INTEGER {atsOverCurrent(1), atsCurrentOK(2)}read-onlymandatory
atsStatus5VPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS 5V power supply. atsPowerSupplyFailure(1) indicates the 5V power supply has failed and that the ATS serial port Configuration Menu is not accessible . atsPowerSupplyOK(2) indicates that the ATS 5V power supply is operating within tolerance. This is only supported by AP77xx SKUs.
1.3.6.1.4.1.318.1.1.8.5.1.5INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatus24VPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS 24V power supply for Source A. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the ATS is unable to switch over to the alternate power source if the current source fails. atsPowerSupplyOK(2) indicates that the ATS 24V power supply is operating within tolerance.
1.3.6.1.4.1.318.1.1.8.5.1.6INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatus24VSourceBPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS 24V power supply for Source B. atsPowerSupplyFailure(1) indicates the 24V power supply has failed and the ATS is unable to switch over to the alternate power source if the current source fails. atsPowerSupplyOK(2) indicates that the ATS 24V power supply is operating within tolerance.
1.3.6.1.4.1.318.1.1.8.5.1.7INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatusPlus12VPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS 12V power supply. atsPowerSupplyFailure(1) indicates the 12V power supply has failed and the ATS is unable to monitor the current sensors. atsPowerSupplyOK(2) indicates that the ATS 12V power supply is operating within tolerance. This is only supported by AP77xx SKUs.
1.3.6.1.4.1.318.1.1.8.5.1.8INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatusMinus12VPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS -12V power supply. atsPowerSupplyFailure(1) indicates the -12V power supply has failed and the ATS is unable to monitor the current sensors. atsPowerSupplyOK(2) indicates that the ATS -12V power supply is operating within tolerance. This is only supported by AP77xx SKUs.
1.3.6.1.4.1.318.1.1.8.5.1.9INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatusSwitchStatus
OBJECT-TYPE
This variable returns the status of the ATS.
1.3.6.1.4.1.318.1.1.8.5.1.10INTEGER {fail(1), ok(2)}read-onlymandatory
atsStatusFrontPanel
OBJECT-TYPE
This variable returns the present state of the ATS front panel. locked(1): Front panel button cannot be used to change the sources. unlocked(2): Front panel button can be used to change the sources.
1.3.6.1.4.1.318.1.1.8.5.1.11INTEGER {locked(1), unlocked(2)}read-onlymandatory
atsStatusSourceAStatus
OBJECT-TYPE
This variable returns the status of the Source A.
1.3.6.1.4.1.318.1.1.8.5.1.12INTEGER {fail(1), ok(2)}read-onlymandatory
atsStatusSourceBStatus
OBJECT-TYPE
This variable returns the status of the Source B.
1.3.6.1.4.1.318.1.1.8.5.1.13INTEGER {fail(1), ok(2)}read-onlymandatory
atsStatusPhaseSyncStatus
OBJECT-TYPE
This variable returns the status of the phase synch.
1.3.6.1.4.1.318.1.1.8.5.1.14INTEGER {inSync(1), outOfSync(2)}read-onlymandatory
atsStatusVoltageOutStatus
OBJECT-TYPE
This variable returns the output voltage status.
1.3.6.1.4.1.318.1.1.8.5.1.15INTEGER {fail(1), ok(2)}read-onlymandatory
atsStatusHardwareStatus
OBJECT-TYPE
This variable returns the status of display board hardware.
1.3.6.1.4.1.318.1.1.8.5.1.16INTEGER {fail(1), ok(2)}read-onlymandatory
atsStatus3dot3VPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS 3.3V power supply. atsPowerSupplyFailure(1) indicates the 3.3V power supply has failed. atsPowerSupplyOK(2) indicates that the ATS 3.3V power supply is operating within tolerance. This is only supported by AP44xx units.
1.3.6.1.4.1.318.1.1.8.5.1.17INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatus1Dot0VPowerSupply
OBJECT-TYPE
This variable returns the present state of the ATS 1.0V power supply. atsPowerSupplyFailure(1) indicates the 1V power supply has failed. atsPowerSupplyOK(2) indicates that the ATS 1.0V power supply is operating within tolerance. This is only supported by AP44xx units.
1.3.6.1.4.1.318.1.1.8.5.1.18INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatusVBoostSourceA
OBJECT-TYPE
This variable returns the present state of the ATS Source A Boost 48V voltage. atsPowerSupplyFailure(1) indicates the ATS Source A Boost 48V voltage has failed. atsPowerSupplyOK(2) indicates that the ATS Source A Boost 48V voltage is operating within tolerance. This is only supported by AP44xx units.
1.3.6.1.4.1.318.1.1.8.5.1.19INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatusVBoostSourceB
OBJECT-TYPE
This variable returns the present state of the ATS Source B Boost 48V voltage. atsPowerSupplyFailure(1) indicates the ATS Source B Boost 48V voltage has failed. atsPowerSupplyOK(2) indicates that the ATS Source B Boost 48V voltage is operating within tolerance. This is only supported by AP44xx units.
1.3.6.1.4.1.318.1.1.8.5.1.20INTEGER {atsPowerSupplyFailure(1), atsPowerSupplyOK(2)}read-onlymandatory
atsStatusResetValues
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.5.2
atsStatusResetMaxMinValues
OBJECT-TYPE
Resets the maximum and minimum ATS values: atsInputMaxVoltage, atsInputMinVoltage, atsInputMaxCurrent, atsInputMinCurrent, atsInputMaxPower, atsInputMinPower, atsOutputMaxCurrent, atsOutputMinCurrent, atsOutputMaxLoad, atsOutputMinLoad, atsOutputMaxPercentLoad, atsOutputMinPercentLoad, atsOutputMaxPower, atsOutputMinPower, atsOutputMaxPercentPower, atsOutputMinPercentPower. These variables represent the maximum and minimum ATS values since the last time they were read or reset by this OID. Values unsupported by this ATS will return (-1).
1.3.6.1.4.1.318.1.1.8.5.2.1INTEGER {none(1), reset(2)}read-writemandatory
atsStatusInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.5.3
atsNumInputs
OBJECT-TYPE
The number of input feeds to this device. This variable indicates the number of rows in the input table.
1.3.6.1.4.1.318.1.1.8.5.3.1INTEGERread-onlymandatory
atsInputTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the value of atsNumInputs.
1.3.6.1.4.1.318.1.1.8.5.3.2not-accessiblemandatory
atsInputEntry
OBJECT-TYPE
An entry containing information applicable to a particular input.
1.3.6.1.4.1.318.1.1.8.5.3.2.1not-accessiblemandatory
atsInputTableIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.8.5.3.2.1.1INTEGERread-onlymandatory
atsNumInputPhases
OBJECT-TYPE
The number of input phases utilized in this device. The sum of all the atsNumInputPhases variable indicates the number of rows in the input phase table.
1.3.6.1.4.1.318.1.1.8.5.3.2.1.2INTEGERread-onlymandatory
atsInputVoltageOrientation
OBJECT-TYPE
The input voltage orientation: 1: unknown for this Source 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
1.3.6.1.4.1.318.1.1.8.5.3.2.1.3INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)}read-onlymandatory
atsInputFrequency
OBJECT-TYPE
The input frequency in Hertz, or -1 if it's unsupported by this Source.
1.3.6.1.4.1.318.1.1.8.5.3.2.1.4INTEGERread-onlymandatory
atsInputType
OBJECT-TYPE
The input type.
1.3.6.1.4.1.318.1.1.8.5.3.2.1.5INTEGER {unknown(1), main(2), bypass(3)}read-onlymandatory
atsInputName
OBJECT-TYPE
A name given to a particular input.
1.3.6.1.4.1.318.1.1.8.5.3.2.1.6DisplayStringread-writemandatory
atsInputPhaseTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the sum of the atsNumInputPhases.
1.3.6.1.4.1.318.1.1.8.5.3.3not-accessiblemandatory
atsInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase.
1.3.6.1.4.1.318.1.1.8.5.3.3.1not-accessiblemandatory
atsInputPhaseTableIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.1INTEGERread-onlymandatory
atsInputPhaseIndex
OBJECT-TYPE
The input phase identifier.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.2INTEGERread-onlymandatory
atsInputVoltage
OBJECT-TYPE
The input voltage in VAC, or -1 if it's unsupported by this Source.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.3INTEGERread-onlymandatory
atsInputMaxVoltage
OBJECT-TYPE
The maximum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.4INTEGERread-onlymandatory
atsInputMinVoltage
OBJECT-TYPE
The minimum input voltage in VAC measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.5INTEGERread-onlymandatory
atsInputCurrent
OBJECT-TYPE
The input current in amperes, or -1 if it's unsupported by this Source.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.6INTEGERread-onlymandatory
atsInputMaxCurrent
OBJECT-TYPE
The maximum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.7INTEGERread-onlymandatory
atsInputMinCurrent
OBJECT-TYPE
The minimum input current in amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.8INTEGERread-onlymandatory
atsInputPower
OBJECT-TYPE
The input power in Watts, or -1 if it's unsupported by this Source.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.9INTEGERread-onlymandatory
atsInputMaxPower
OBJECT-TYPE
The maximum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.10INTEGERread-onlymandatory
atsInputMinPower
OBJECT-TYPE
The minimum input power in Watts measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.3.3.1.11INTEGERread-onlymandatory
atsStatusOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.8.5.4
atsNumOutputs
OBJECT-TYPE
The number of output feeds to this device. This variable indicates the number of rows in the output table.
1.3.6.1.4.1.318.1.1.8.5.4.1INTEGERread-onlymandatory
atsOutputTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the value of atsOutputNumPhases.
1.3.6.1.4.1.318.1.1.8.5.4.2not-accessiblemandatory
atsOutputEntry
OBJECT-TYPE
An entry containing information applicable to a particular output.
1.3.6.1.4.1.318.1.1.8.5.4.2.1not-accessiblemandatory
atsOutputTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.8.5.4.2.1.1INTEGERread-onlymandatory
atsNumOutputPhases
OBJECT-TYPE
The number of output phases utilized in this device. The sum of all the atsNumOutputPhases variable indicates the number of rows in the output phase table.
1.3.6.1.4.1.318.1.1.8.5.4.2.1.2INTEGERread-onlymandatory
atsOutputVoltageOrientation
OBJECT-TYPE
The output voltage orientation: 1: unknown for this ATS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
1.3.6.1.4.1.318.1.1.8.5.4.2.1.3INTEGER {unknown(1), singlePhase(2), splitPhase(3), threePhasePhaseToNeutral(4), threePhasePhaseToPhase(5)}read-onlymandatory
atsOutputFrequency
OBJECT-TYPE
The output frequency in Hertz, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.2.1.4INTEGERread-onlymandatory
atsOutputPhaseTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the sum of the atsNumOutputPhases.
1.3.6.1.4.1.318.1.1.8.5.4.3not-accessiblemandatory
atsOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular output phase.
1.3.6.1.4.1.318.1.1.8.5.4.3.1not-accessiblemandatory
atsOutputPhaseTableIndex
OBJECT-TYPE
The output identifier.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.1INTEGERread-onlymandatory
atsOutputPhaseIndex
OBJECT-TYPE
Description of each output phase utilized in this device and one for neutral.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.2INTEGER {phase1(1), phase2(2), phase3(3), neutral(4)}read-onlymandatory
atsOutputVoltage
OBJECT-TYPE
The output voltage in VAC, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.3INTEGERread-onlymandatory
atsOutputCurrent
OBJECT-TYPE
The output current in 0.1 amperes drawn by the load on the ATS, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.4INTEGERread-onlymandatory
atsOutputMaxCurrent
OBJECT-TYPE
The maximum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.5INTEGERread-onlymandatory
atsOutputMinCurrent
OBJECT-TYPE
The minimum output current in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.6INTEGERread-onlymandatory
atsOutputLoad
OBJECT-TYPE
The output load in VA, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.7INTEGERread-onlymandatory
atsOutputMaxLoad
OBJECT-TYPE
The maximum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.8INTEGERread-onlymandatory
atsOutputMinLoad
OBJECT-TYPE
The minimum output load in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.9INTEGERread-onlymandatory
atsOutputPercentLoad
OBJECT-TYPE
The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.10INTEGERread-onlymandatory
atsOutputMaxPercentLoad
OBJECT-TYPE
The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.11INTEGERread-onlymandatory
atsOutputMinPercentLoad
OBJECT-TYPE
The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.12INTEGERread-onlymandatory
atsOutputPower
OBJECT-TYPE
The output apparent power in VA, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.13INTEGERread-onlymandatory
atsOutputMaxPower
OBJECT-TYPE
The maximum output power in VAs measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.14INTEGERread-onlymandatory
atsOutputMinPower
OBJECT-TYPE
The minimum output power in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.15INTEGERread-onlymandatory
atsOutputPercentPower
OBJECT-TYPE
The percentage of the ATSpower capacity in VA at redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.16INTEGERread-onlymandatory
atsOutputMaxPercentPower
OBJECT-TYPE
The maximum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.17INTEGERread-onlymandatory
atsOutputMinPercentPower
OBJECT-TYPE
The minimum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.18INTEGERread-onlymandatory
atsOutputPhaseState
OBJECT-TYPE
Getting this OID will return the phase load state. normal(1) indicates that the bank is operating properly within the atsConfigPhaseLowLoadThreshold and atsConfigPhaseNearOverLoadThreshold OID values. lowload(2) indicates that the bank load has dropped below the atsConfigPhaseLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. nearoverload(3) indicates that the bank load is greater than or equal to the atsConfigPhaseNearOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. overload(4) indicates that the bank load is greater than or equal to the atsConfigPhaseOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
1.3.6.1.4.1.318.1.1.8.5.4.3.1.19INTEGER {normal(1), lowload(2), nearoverload(3), overload(4)}read-onlymandatory
atsOutputBankTableSize
OBJECT-TYPE
The size of the bank table.
1.3.6.1.4.1.318.1.1.8.5.4.4INTEGERread-onlymandatory
atsOutputBankTable
OBJECT-TYPE
Allows for getting table entries.
1.3.6.1.4.1.318.1.1.8.5.4.5not-accessiblemandatory
atsOutputBankEntry
OBJECT-TYPE
This gives access to bank table entries
1.3.6.1.4.1.318.1.1.8.5.4.5.1not-accessiblemandatory
atsOutputBankTableIndex
OBJECT-TYPE
The index to the bank table entry.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.1INTEGERread-onlymandatory
atsOutputPhase
OBJECT-TYPE
The phase number of an ATS
1.3.6.1.4.1.318.1.1.8.5.4.5.1.2INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
atsOutputBank
OBJECT-TYPE
The bank number of an ATS
1.3.6.1.4.1.318.1.1.8.5.4.5.1.3INTEGER {total(1), bank1(2), bank2(3)}read-onlymandatory
atsOutputBankCurrent
OBJECT-TYPE
Getting this OID will return the bank current measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.4Gaugeread-onlymandatory
atsOutputBankState
OBJECT-TYPE
Getting this OID will return the bank load state. normal(1) indicates that the bank is operating properly within the atsConfigBankLowLoadThreshold and atsConfigBankNearOverLoadThreshold OID values. lowload(2) indicates that the bank load has dropped below the atsConfigBankLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. nearoverload(3) indicates that the bank load is greater than or equal to the atsConfigBankNearOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. overload(4) indicates that the bank load is greater than or equal to the atsConfigBankOverLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.5INTEGER {normal(1), lowload(2), nearoverload(3), overload(4)}read-onlymandatory
atsOutputBankOutputVoltage
OBJECT-TYPE
The output voltage in VAC, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.6INTEGERread-onlymandatory
atsOutputBankMaxCurrent
OBJECT-TYPE
The maximum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.7INTEGERread-onlymandatory
atsOutputBankMinCurrent
OBJECT-TYPE
The minimum output current, on the bank represented by OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.8INTEGERread-onlymandatory
atsOutputBankLoad
OBJECT-TYPE
The output load, on the bank represented by OID atsOutputBank, in VA, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.9INTEGERread-onlymandatory
atsOutputBankMaxLoad
OBJECT-TYPE
The maximum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.10INTEGERread-onlymandatory
atsOutputBankMinLoad
OBJECT-TYPE
The minimum output load, on the bank represented by OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.11INTEGERread-onlymandatory
atsOutputBankPercentLoad
OBJECT-TYPE
The percentage of the ATS load capacity in VA at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank. Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.12INTEGERread-onlymandatory
atsOutputBankMaxPercentLoad
OBJECT-TYPE
The maximum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.13INTEGERread-onlymandatory
atsOutputBankMinPercentLoad
OBJECT-TYPE
The minimum percentage of the ATS load capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.14INTEGERread-onlymandatory
atsOutputBankPower
OBJECT-TYPE
The output apparent power in VA on the bank represented by OID atsOutputBank or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.15INTEGERread-onlymandatory
atsOutputBankMaxPower
OBJECT-TYPE
The maximum output power in VA measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.16INTEGERread-onlymandatory
atsOutputBankMinPower
OBJECT-TYPE
The minimum output power in VA measured on the bank represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.17INTEGERread-onlymandatory
atsOutputBankPercentPower
OBJECT-TYPE
The percentage of the ATSpower capacity in Watts at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, or -1 if it's unsupported by this ATS.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.18INTEGERread-onlymandatory
atsOutputBankMaxPercentPower
OBJECT-TYPE
The maximum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.19INTEGERread-onlymandatory
atsOutputBankMinPercentPower
OBJECT-TYPE
The minimum percentage of the ATSpower capacity in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported.
1.3.6.1.4.1.318.1.1.8.5.4.5.1.20INTEGERread-onlymandatory
dc2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9
dcmim2Ident
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.1
dcmim2IdentSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.1.1
dcmim2IdentSysFWVersion
OBJECT-TYPE
Integer representation of the power plant Master Controller firmware revision.
1.3.6.1.4.1.318.1.1.9.1.1.1INTEGERread-onlymandatory
dcmim2Control
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.2
dcmim2ControlSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.2.1
dcmim2ControlRunFunctBatteryTest
OBJECT-TYPE
Getting this OID will return the battery functional test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery functional test off. Setting this OID to battTestOn (2) will turn the battery functional test on.
1.3.6.1.4.1.318.1.1.9.2.1.1INTEGER {battTestOff(1), battTestOn(2)}read-writemandatory
dcmim2ControlRunCapacityBatteryTest
OBJECT-TYPE
Getting this OID will return the battery capacity test state. If the test is off, the battTestOff (1) value will be returned. If the test is on, the battTestOn (2) value will be returned. Setting this OID to battTestOff (1) will turn the battery capacity test off. Setting this OID to battTestOn (2) will turn the battery capacity test on.
1.3.6.1.4.1.318.1.1.9.2.1.2INTEGER {battTestOff(1), battTestOn(2)}read-writemandatory
dcmim2Config
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.3
dcmim2ConfigSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.3.1
dcmim2ConfigSysHighTempTrip
OBJECT-TYPE
Trip level (threshold) at which System High Temp alarm condition is created. Range 28 to 100 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.9.3.1.1INTEGERread-writemandatory
dcmim2ConfigSysHighTempReset
OBJECT-TYPE
Level at which System High Temp alarm condition is reset (cleared). Range 25 to (upper temp - 3) (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.9.3.1.2INTEGERread-writemandatory
dcmim2ConfigSysLowTempTrip
OBJECT-TYPE
Trip level (threshold) at which System Low Temp alarm condition is created. Range -100 to 10 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.9.3.1.3INTEGERread-writemandatory
dcmim2ConfigSysLowTempReset
OBJECT-TYPE
Level at which System Low Temp alarm condition is reset (cleared). Range (lower temp + 3) to 13 (degC). Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.9.3.1.4INTEGERread-writemandatory
dcmim2ConfigBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.3.2
dcmim2ConfigBattFloatVolt
OBJECT-TYPE
Battery Float Voltage defined at 25 degrees Celsius. Values are represented in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.3.2.1INTEGERread-writemandatory
dcmim2ConfigBattMaxRecharge
OBJECT-TYPE
Battery Maximum Recharge Rate. This is the maximum current used during battery charging. Values are represented in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.9.3.2.2INTEGERread-writemandatory
dcmim2ConfigBattMfgCapacity
OBJECT-TYPE
Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr).
1.3.6.1.4.1.318.1.1.9.3.2.3INTEGERread-writemandatory
dcmim2ConfigBattType
OBJECT-TYPE
Type of battery in the powerplant Valid values range from 0 to 254.
1.3.6.1.4.1.318.1.1.9.3.2.4INTEGERread-writemandatory
dcmim2ConfigBattFunctTestDuration
OBJECT-TYPE
Duration of the battery functional test. Values are represented in thousandths of seconds (mSecs).
1.3.6.1.4.1.318.1.1.9.3.2.5INTEGERread-writemandatory
dcmim2ConfigBattFunctTestThresh
OBJECT-TYPE
Threshold the battery voltage of the system must remain above in order to pass the battery functional test. Values are represented in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.3.2.6INTEGERread-writemandatory
dcmim2ConfigBattCapacityTestPercent
OBJECT-TYPE
Threshold for good battery capacity test results. Values range from 0 to 100 percent.
1.3.6.1.4.1.318.1.1.9.3.2.7INTEGERread-writemandatory
dcmim2ConfigBattCapacityTestEndThresh
OBJECT-TYPE
Safeguard voltage at which battery capacity test will end if there is a battery problem. Values are represented in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.3.2.8INTEGERread-writemandatory
dcmim2ConfigBattCapacityTestCurrent
OBJECT-TYPE
Constant current value used during battery capacity testing. Values are represented in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.9.3.2.9INTEGERread-writemandatory
dcmim2ConfigLVD
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.3.3
dcmim2ConfigLVDTableSize
OBJECT-TYPE
The number of DC powerplant LVDs controllable by this IP address.
1.3.6.1.4.1.318.1.1.9.3.3.1INTEGERread-onlymandatory
dcmim2ConfigLVDTable
OBJECT-TYPE
Allows for accessing settings of the LVDs. The number of entries is contained in the dcmim2ConfigLVDTableSize OID.
1.3.6.1.4.1.318.1.1.9.3.3.2not-accessiblemandatory
dcmim2ConfigLVDEntry
OBJECT-TYPE
The LVD to configure.
1.3.6.1.4.1.318.1.1.9.3.3.2.1not-accessiblemandatory
dcmim2ConfigLVDIndex
OBJECT-TYPE
The index to the DC powerplant LVD.
1.3.6.1.4.1.318.1.1.9.3.3.2.1.1INTEGERread-onlymandatory
dcmim2ConfigLVDTrip
OBJECT-TYPE
LVD Trip threshold. System bus voltage at which LVD will trip (open) during a battery backup operation. Values are represented in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.3.3.2.1.2INTEGERread-writemandatory
dcmim2ConfigLVDReset
OBJECT-TYPE
LVD Reset threshold. System bus voltage at which LVD will reset (close) after AC power has been restored. Values are represented in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.3.3.2.1.3INTEGERread-writemandatory
dcmim2ConfigLVDState
OBJECT-TYPE
Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened.
1.3.6.1.4.1.318.1.1.9.3.3.2.1.4INTEGER {statusClosed(1), statusOpened(2)}read-onlymandatory
dcmim2Status
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.4
dcmim2StatusSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.4.1
dcmim2StatusSysRectCurrent
OBJECT-TYPE
System (Total Rectifier) current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.9.4.1.1INTEGERread-onlymandatory
dcmim2StatusSysLoadCurrent
OBJECT-TYPE
Load current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.9.4.1.2INTEGERread-onlymandatory
dcmim2StatusSysBusVoltage
OBJECT-TYPE
System bus voltage in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.4.1.3INTEGERread-onlymandatory
dcmim2StatusSysAmbientTemp
OBJECT-TYPE
System temperature based on sensor on Master Controller PCB. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.9.4.1.4INTEGERread-onlymandatory
dcmim2StatusSysUpTime
OBJECT-TYPE
Length of time since the DC Powerplant controller has been powered up.
1.3.6.1.4.1.318.1.1.9.4.1.5DisplayStringread-onlymandatory
dcmim2StatusSysTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature in the DC system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.9.4.1.6INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
dcmim2StatusRectifier
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.4.2
dcmim2StatusRectTableSize
OBJECT-TYPE
The number of DC powerplant rectifiers viewable by this IP address.
1.3.6.1.4.1.318.1.1.9.4.2.1INTEGERread-onlymandatory
dcmim2StatusRectTable
OBJECT-TYPE
Allows for accessing settings of the rectifiers. The number of entries is contained in the dcmim2StatusRectTableSize OID.
1.3.6.1.4.1.318.1.1.9.4.2.2not-accessiblemandatory
dcmim2StatusRectEntry
OBJECT-TYPE
The rectifier to gather status from.
1.3.6.1.4.1.318.1.1.9.4.2.2.1not-accessiblemandatory
dcmim2StatusRectIndex
OBJECT-TYPE
The index to the DC powerplant rectifier.
1.3.6.1.4.1.318.1.1.9.4.2.2.1.1INTEGERread-onlymandatory
dcmim2StatusRectDevType
OBJECT-TYPE
This OID shows the rectifier device type.
1.3.6.1.4.1.318.1.1.9.4.2.2.1.2INTEGERread-onlymandatory
dcmim2StatusRectID
OBJECT-TYPE
This OID shows the rectifier ID. This enumerates the number of the rectifier within a group of rectifiers.
1.3.6.1.4.1.318.1.1.9.4.2.2.1.3INTEGERread-onlymandatory
dcmim2StatusRectPhyAddr
OBJECT-TYPE
This OID shows the rectifier physical address (the address on the bus).
1.3.6.1.4.1.318.1.1.9.4.2.2.1.4INTEGERread-onlymandatory
dcmim2StatusRectFail
OBJECT-TYPE
Getting this OID will return statusTrue (1) if the rectifier has failed. statusFalse (2) will be returned if the rectifier has not failed.
1.3.6.1.4.1.318.1.1.9.4.2.2.1.5INTEGER {statusTrue(1), statusFalse(2)}read-onlymandatory
dcmim2StatusRectCurrent
OBJECT-TYPE
This OID shows the individual rectifier current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.9.4.2.2.1.6INTEGERread-onlymandatory
dcmim2StatusBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.4.3
dcmim2StatusBattFloatVolt
OBJECT-TYPE
Battery Float Voltage represented in thousandths of Volts (mV).
1.3.6.1.4.1.318.1.1.9.4.3.1INTEGERread-onlymandatory
dcmim2StatusBattCurrent
OBJECT-TYPE
Battery Current: This OID shows the battery current in thousandths of Amps (mA).
1.3.6.1.4.1.318.1.1.9.4.3.2INTEGERread-onlymandatory
dcmim2StatusBattTemp
OBJECT-TYPE
Battery Temperature: Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.9.4.3.3INTEGERread-onlymandatory
dcmim2StatusBattMfgCapacity
OBJECT-TYPE
Battery capacity (Amp-Hour Size) as specified by the battery manufacturer. Values are represented in thousandths of Amp hours (mAHr).
1.3.6.1.4.1.318.1.1.9.4.3.4INTEGERread-onlymandatory
dcmim2StatusBattTestCapacity
OBJECT-TYPE
Battery capacity (Amp-Hour Size) as determined by the battery capacity test. Values are represented in thousandths of Amp hours (mAHr).
1.3.6.1.4.1.318.1.1.9.4.3.5INTEGERread-onlymandatory
dcmim2StatusBattFunctTestResult
OBJECT-TYPE
Results of the last battery functional test that was run.
1.3.6.1.4.1.318.1.1.9.4.3.6INTEGER {functTestNotPerformed(1), functTestInProcess(2), functTestInterrupted(3), functTestPass(4), functTestFail(5)}read-onlymandatory
dcmim2StatusBattCapacityTestResult
OBJECT-TYPE
Results of the last battery capacity test that was run.
1.3.6.1.4.1.318.1.1.9.4.3.7INTEGER {capacityTestNotPerformed(1), capacityTestInProcess(2), capacityTestInterrupted(3), capacityTestPass(4), capacityTestFail(5)}read-onlymandatory
dcmim2StatusLVD
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.4.4
dcmim2StatusLVDTableSize
OBJECT-TYPE
The number of DC powerplant LVDs accessible by this IP address.
1.3.6.1.4.1.318.1.1.9.4.4.1INTEGERread-onlymandatory
dcmim2StatusLVDTable
OBJECT-TYPE
Allows for accessing the LVDs. The number of entries is contained in the dcmim2StatusLVDTableSize OID.
1.3.6.1.4.1.318.1.1.9.4.4.2not-accessiblemandatory
dcmim2StatusLVDEntry
OBJECT-TYPE
The LVD to access.
1.3.6.1.4.1.318.1.1.9.4.4.2.1not-accessiblemandatory
dcmim2StatusLVDIndex
OBJECT-TYPE
The index to the DC powerplant LVD.
1.3.6.1.4.1.318.1.1.9.4.4.2.1.1INTEGERread-onlymandatory
dcmim2StatusLVDState
OBJECT-TYPE
Getting this OID will return statusClosed (1) if the LVD is closed. statusOpened (2) will be returned if the LVD is opened.
1.3.6.1.4.1.318.1.1.9.4.4.2.1.2INTEGER {statusClosed(1), statusOpened(2)}read-onlymandatory
dcmim2StatusAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.9.4.5
dcmim2StatusAlarmsTableSize
OBJECT-TYPE
The number of DC powerplant alarms viewable by this IP address.
1.3.6.1.4.1.318.1.1.9.4.5.1INTEGERread-onlymandatory
dcmim2StatusAlarmsTable
OBJECT-TYPE
Allows for accessing system alarms. The number of entries is contained in the dcmim2StatusAlarmsTableSize OID.
1.3.6.1.4.1.318.1.1.9.4.5.2not-accessiblemandatory
dcmim2StatusAlarmsEntry
OBJECT-TYPE
The alarm to display.
1.3.6.1.4.1.318.1.1.9.4.5.2.1not-accessiblemandatory
dcmim2StatusAlarmsIndex
OBJECT-TYPE
The index of the system alarm.
1.3.6.1.4.1.318.1.1.9.4.5.2.1.1INTEGERread-onlymandatory
dcmim2StatusAlarmsText
OBJECT-TYPE
The 16 character text describing the active alarm condition.
1.3.6.1.4.1.318.1.1.9.4.5.2.1.2DisplayStringread-onlymandatory
environmentalMonitor
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10
external
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.1
emIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.1.1
emIdentFirmwareRevision
OBJECT-TYPE
The firmware revision of the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.1.1.1DisplayStringread-onlymandatory
emConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.1.2
emConfigProbesNumProbes
OBJECT-TYPE
The number of temperature and humidity probes available.
1.3.6.1.4.1.318.1.1.10.1.2.1INTEGERread-onlymandatory
emConfigProbesTable
OBJECT-TYPE
A list of probes supported by the Environmental Monitor and their configurations.
1.3.6.1.4.1.318.1.1.10.1.2.2not-accessiblemandatory
emConfigProbesEntry
OBJECT-TYPE
The Environmental Monitor probe configurations.
1.3.6.1.4.1.318.1.1.10.1.2.2.1not-accessiblemandatory
emConfigProbeNumber
OBJECT-TYPE
The index into an Environmental Monitor probe entry.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.1INTEGERread-onlymandatory
emConfigProbeName
OBJECT-TYPE
A descriptive name of the probe set by the user, possibly denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.2DisplayStringread-writemandatory
emConfigProbeHighTempThreshold
OBJECT-TYPE
The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.2.2.1.3INTEGERread-writemandatory
emConfigProbeLowTempThreshold
OBJECT-TYPE
The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.2.2.1.4INTEGERread-writemandatory
emConfigProbeTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.5INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
emConfigProbeHighHumidThreshold
OBJECT-TYPE
The high humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.6INTEGERread-writemandatory
emConfigProbeLowHumidThreshold
OBJECT-TYPE
The low humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.7INTEGERread-writemandatory
emConfigProbeHighTempEnable
OBJECT-TYPE
The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.8INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeLowTempEnable
OBJECT-TYPE
The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.9INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeHighHumidEnable
OBJECT-TYPE
The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.10INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeLowHumidEnable
OBJECT-TYPE
The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.11INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeMaxTempThreshold
OBJECT-TYPE
The maximum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.2.2.1.12INTEGERread-writemandatory
emConfigProbeMinTempThreshold
OBJECT-TYPE
The minimum temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.2.2.1.13INTEGERread-writemandatory
emConfigProbeMaxHumidThreshold
OBJECT-TYPE
The maximun humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.14INTEGERread-writemandatory
emConfigProbeMinHumidThreshold
OBJECT-TYPE
The minimum humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.15INTEGERread-writemandatory
emConfigProbeMaxTempEnable
OBJECT-TYPE
The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.16INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeMinTempEnable
OBJECT-TYPE
The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.17INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeMaxHumidEnable
OBJECT-TYPE
The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.18INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeMinHumidEnable
OBJECT-TYPE
The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.19INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigProbeTempHysteresis
OBJECT-TYPE
The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.2.2.1.20INTEGERread-writemandatory
emConfigProbeHumidHysteresis
OBJECT-TYPE
The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.2.2.1.21INTEGERread-writemandatory
emConfigProbeLocation
OBJECT-TYPE
A string describing the location of the probe.
1.3.6.1.4.1.318.1.1.10.1.2.2.1.22DisplayStringread-writemandatory
emConfigContactsNumContacts
OBJECT-TYPE
The number of contacts supported by the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.1.2.3INTEGERread-onlymandatory
emConfigContactsTable
OBJECT-TYPE
A list of contacts supported by the Environmental Monitor and their configurations.
1.3.6.1.4.1.318.1.1.10.1.2.4not-accessiblemandatory
emConfigContactsEntry
OBJECT-TYPE
The Environmental Monitor contact configurations.
1.3.6.1.4.1.318.1.1.10.1.2.4.1not-accessiblemandatory
emConfigContactNumber
OBJECT-TYPE
The index of an Environmental Monitor contact.
1.3.6.1.4.1.318.1.1.10.1.2.4.1.1INTEGERread-onlymandatory
emConfigContactName
OBJECT-TYPE
A descriptive name for an Environmental Monitor contact set by the user, possibly denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.1.2.4.1.2DisplayStringread-writemandatory
emConfigContactEnable
OBJECT-TYPE
An Environmental Monitor contact alarm enable/disable. No alarm will be generated if the contact is disabled(1). An alarm will be generated if the contact is enabled(2) and the contact has been faulted.
1.3.6.1.4.1.318.1.1.10.1.2.4.1.3INTEGER {disabled(1), enabled(2)}read-writemandatory
emConfigContactSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.1.2.4.1.4INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
emConfigContactNormalState
OBJECT-TYPE
The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2).
1.3.6.1.4.1.318.1.1.10.1.2.4.1.5INTEGER {open(1), closed(2)}read-writemandatory
emConfigContactLocation
OBJECT-TYPE
A descriptive label for the contact denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.1.2.4.1.6DisplayStringread-writemandatory
emStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.1.3
emStatusCommStatus
OBJECT-TYPE
The communication status between the agent and the Environmental Monitor. noComm(1), Communication has never been established. comm(2), Communication has been established. commLost(3), Communication was established, but was lost.
1.3.6.1.4.1.318.1.1.10.1.3.1INTEGER {noComm(1), comm(2), commLost(3)}read-onlymandatory
emStatusProbesNumProbes
OBJECT-TYPE
The number of available probes on the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.1.3.2INTEGERread-onlymandatory
emStatusProbesTable
OBJECT-TYPE
A list of probes supported by the Environmental Monitor and their status.
1.3.6.1.4.1.318.1.1.10.1.3.3not-accessiblemandatory
emStatusProbesEntry
OBJECT-TYPE
The status of the probe.
1.3.6.1.4.1.318.1.1.10.1.3.3.1not-accessiblemandatory
emStatusProbeNumber
OBJECT-TYPE
The index of the probe.
1.3.6.1.4.1.318.1.1.10.1.3.3.1.1INTEGERread-onlymandatory
emStatusProbeName
OBJECT-TYPE
A descriptive name for the probe set by the user, possibly denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.1.3.3.1.2DisplayStringread-onlymandatory
emStatusProbeStatus
OBJECT-TYPE
The connected status of the probe, either disconnected(1) or connected(2).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.3INTEGER {disconnected(1), connected(2)}read-onlymandatory
emStatusProbeCurrentTemp
OBJECT-TYPE
The current temperature reading from the probe displayed in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.4INTEGERread-onlymandatory
emStatusProbeTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.10.1.3.3.1.5INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
emStatusProbeCurrentHumid
OBJECT-TYPE
The current humidity reading from the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.1.3.3.1.6INTEGERread-onlymandatory
emStatusProbeHighTempViolation
OBJECT-TYPE
The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to the high temperature threshold value, the 'emConfigProbeHighTempThreshold' OID, and the value of the 'emConfigProbeHighTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeHighTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.7INTEGER {noViolation(1), highTempViolation(2), disabled(3)}read-onlymandatory
emStatusProbeLowTempViolation
OBJECT-TYPE
The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to the low temperature threshold value, the 'emConfigProbeLowTempThreshold' OID, and the value of the 'emConfigProbeLowTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeLowTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.8INTEGER {noViolation(1), lowTempViolation(2), disabled(3)}read-onlymandatory
emStatusProbeHighHumidViolation
OBJECT-TYPE
The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the high humidity threshold value, the 'emConfigProbeHighHumidThreshold' OID, and the value of the 'emConfigProbeHighHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeHighHumidEnable' OID is disabled, this OID will show disabled(3)
1.3.6.1.4.1.318.1.1.10.1.3.3.1.9INTEGER {noViolation(1), highHumidViolation(2), disabled(3)}read-onlymandatory
emStatusProbeLowHumidViolation
OBJECT-TYPE
The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the low humidity threshold value, the 'emConfigProbeLowHumidThreshold' OID, and the value of the 'emConfigProbeLowHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeLowHumidEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.10INTEGER {noViolation(1), lowHumidViolation(2), disabled(3)}read-onlymandatory
emStatusProbeMaxTempViolation
OBJECT-TYPE
The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to the maximun temperature threshold value, the 'emConfigProbeMaxTempThreshold' OID, and the value of the 'emConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMaxTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.11INTEGER {noViolation(1), maxTempViolation(2), disabled(3)}read-onlymandatory
emStatusProbeMinTempViolation
OBJECT-TYPE
The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to the minimum temperature threshold value, the 'emConfigProbeMinTempThreshold' OID, and the value of the 'emConfigProbeMinTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMinTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.12INTEGER {noViolation(1), minTempViolation(2), disabled(3)}read-onlymandatory
emStatusProbeMaxHumidViolation
OBJECT-TYPE
The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the maximum humidity threshold value, the 'emConfigProbeMaxHumidThreshold' OID, and the value of the 'emConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMaxHumidEnable' OID is disabled, this OID will show disabled(3)
1.3.6.1.4.1.318.1.1.10.1.3.3.1.13INTEGER {noViolation(1), maxHumidViolation(2), disabled(3)}read-onlymandatory
emStatusProbeMinHumidViolation
OBJECT-TYPE
The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the minimum humidity threshold value, the 'emConfigProbeMinHumidThreshold' OID, and the value of the 'emConfigProbeMinHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'emConfigProbeMinHumidEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.3.1.14INTEGER {noViolation(1), minHumidViolation(2), disabled(3)}read-onlymandatory
emStatusContactsNumContacts
OBJECT-TYPE
The number of contacts supported by the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.1.3.4INTEGERread-onlymandatory
emStatusContactsTable
OBJECT-TYPE
A list of contacts supported by the Environmental Monitor and their status.
1.3.6.1.4.1.318.1.1.10.1.3.5not-accessiblemandatory
emStatusContactsEntry
OBJECT-TYPE
The status of the contact.
1.3.6.1.4.1.318.1.1.10.1.3.5.1not-accessiblemandatory
emStatusContactNumber
OBJECT-TYPE
The index of the Environmental Monitor contact.
1.3.6.1.4.1.318.1.1.10.1.3.5.1.1INTEGERread-onlymandatory
emStatusContactName
OBJECT-TYPE
A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.1.3.5.1.2DisplayStringread-onlymandatory
emStatusContactStatus
OBJECT-TYPE
The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'emConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is faulted and the 'emContactEnable' OID is enabled. If the 'emConfigContactEnable' OID is disabled, the status will show disabled(3).
1.3.6.1.4.1.318.1.1.10.1.3.5.1.3INTEGER {noFault(1), fault(2), disabled(3)}read-onlymandatory
integrated
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.2
iemIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.2.1
iemIdentHardwareRevision
OBJECT-TYPE
The hardware revision of the Integrated Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.2.1.1DisplayStringread-onlymandatory
iemConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.2.2
iemConfigProbesNumProbes
OBJECT-TYPE
The number of temperature and humidity probes available.
1.3.6.1.4.1.318.1.1.10.2.2.1INTEGERread-onlymandatory
iemConfigProbesTable
OBJECT-TYPE
A list of probes supported by the Environmental Monitor and their configurations.
1.3.6.1.4.1.318.1.1.10.2.2.2not-accessiblemandatory
iemConfigProbesEntry
OBJECT-TYPE
The Environmental Monitor probe configurations.
1.3.6.1.4.1.318.1.1.10.2.2.2.1not-accessiblemandatory
iemConfigProbeNumber
OBJECT-TYPE
The index to a Environmental Monitor probe entry.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.1INTEGERread-onlymandatory
iemConfigProbeName
OBJECT-TYPE
A descriptive name for the probe set by the user, possibly denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.2DisplayStringread-writemandatory
iemConfigProbeHighTempThreshold
OBJECT-TYPE
The high temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.2.2.1.3INTEGERread-writemandatory
iemConfigProbeLowTempThreshold
OBJECT-TYPE
The low temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.2.2.1.4INTEGERread-writemandatory
iemConfigProbeTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.5INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
iemConfigProbeHighHumidThreshold
OBJECT-TYPE
The high humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.6INTEGERread-writemandatory
iemConfigProbeLowHumidThreshold
OBJECT-TYPE
The low humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.7INTEGERread-writemandatory
iemConfigProbeHighTempEnable
OBJECT-TYPE
The high temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.8INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeLowTempEnable
OBJECT-TYPE
The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.9INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeHighHumidEnable
OBJECT-TYPE
The high humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.10INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeLowHumidEnable
OBJECT-TYPE
The low humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.11INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeMaxTempThreshold
OBJECT-TYPE
The maximun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.2.2.1.12INTEGERread-writemandatory
iemConfigProbeMinTempThreshold
OBJECT-TYPE
The minimun temperature alarm threshold for the probe. Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.2.2.1.13INTEGERread-writemandatory
iemConfigProbeMaxHumidThreshold
OBJECT-TYPE
The maximum humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.14INTEGERread-writemandatory
iemConfigProbeMinHumidThreshold
OBJECT-TYPE
The minimum humidity alarm threshold for the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.15INTEGERread-writemandatory
iemConfigProbeMaxTempEnable
OBJECT-TYPE
The maximum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.16INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeMinTempEnable
OBJECT-TYPE
The low temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.17INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeMaxHumidEnable
OBJECT-TYPE
The maximum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.18INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeMinHumidEnable
OBJECT-TYPE
The minimum humidity alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.19INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigProbeTempHysteresis
OBJECT-TYPE
The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.2.2.1.20INTEGERread-writemandatory
iemConfigProbeHumidHysteresis
OBJECT-TYPE
The number of percent RH points beyond the humidity thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.2.2.1.21INTEGERread-writemandatory
iemConfigProbeLocation
OBJECT-TYPE
A string describing the location of the probe.
1.3.6.1.4.1.318.1.1.10.2.2.2.1.22DisplayStringread-writemandatory
iemConfigContactsNumContacts
OBJECT-TYPE
The number of contacts available on the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.2.2.3INTEGERread-onlymandatory
iemConfigContactsTable
OBJECT-TYPE
A list of contacts supported by the Environmental Monitor and their configurations.
1.3.6.1.4.1.318.1.1.10.2.2.4not-accessiblemandatory
iemConfigContactsEntry
OBJECT-TYPE
The Environmental Monitor contact configurations.
1.3.6.1.4.1.318.1.1.10.2.2.4.1not-accessiblemandatory
iemConfigContactNumber
OBJECT-TYPE
The index of an Environmental Monitor contact.
1.3.6.1.4.1.318.1.1.10.2.2.4.1.1INTEGERread-onlymandatory
iemConfigContactName
OBJECT-TYPE
A descriptive name for the Environmental Monitor contact set by the user, possibly denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.2.2.4.1.2DisplayStringread-writemandatory
iemConfigContactEnable
OBJECT-TYPE
An Environmental Monitor contact alarm enable/disable.
1.3.6.1.4.1.318.1.1.10.2.2.4.1.3INTEGER {disabled(1), enabled(2)}read-writemandatory
iemConfigContactSeverity
OBJECT-TYPE
The severtity of the alarm that will be triggered when the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). NOTE: informational(3) is deprecated (and no longer valid) for this OID.
1.3.6.1.4.1.318.1.1.10.2.2.4.1.4INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
iemConfigContactNormalState
OBJECT-TYPE
The contact state that will be considered normal, i.e. will not trigger an alarm. The states are open(1) or closed(2).
1.3.6.1.4.1.318.1.1.10.2.2.4.1.5INTEGER {open(1), closed(2)}read-writemandatory
iemConfigContactLocation
OBJECT-TYPE
A descriptive label for the contact denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.2.2.4.1.6DisplayStringread-writemandatory
iemConfigConfigRelaysNumRelays
OBJECT-TYPE
The number of output relays supported by the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.2.2.5INTEGERread-onlymandatory
iemConfigRelaysTable
OBJECT-TYPE
A list of output relays supported by the Environmental Monitor and their configurations.
1.3.6.1.4.1.318.1.1.10.2.2.6not-accessiblemandatory
iemConfigRelaysEntry
OBJECT-TYPE
The Environmental Monitor output relay configurations.
1.3.6.1.4.1.318.1.1.10.2.2.6.1not-accessiblemandatory
iemConfigRelayNumber
OBJECT-TYPE
The index of an Environmental Monitor output relay.
1.3.6.1.4.1.318.1.1.10.2.2.6.1.1INTEGERread-onlymandatory
iemConfigRelayName
OBJECT-TYPE
A descriptive name of an Environmental Monitor output relay, set by the user, describing its location or purpose.
1.3.6.1.4.1.318.1.1.10.2.2.6.1.2DisplayStringread-writemandatory
iemConfigRelayNormalState
OBJECT-TYPE
The normal state (non-fault state) of an Environmental Monitor output relay, either open(1) or closed(2).
1.3.6.1.4.1.318.1.1.10.2.2.6.1.3INTEGER {open(1), closed(2)}read-writemandatory
iemConfigRelayFaultCondition
OBJECT-TYPE
The fault condition used to activate the output relay.
1.3.6.1.4.1.318.1.1.10.2.2.6.1.4INTEGERread-writemandatory
iemStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.2.3
iemStatusProbesNumProbes
OBJECT-TYPE
The number of available probes on the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.2.3.1INTEGERread-onlymandatory
iemStatusProbesTable
OBJECT-TYPE
A list of probes supported by the Environmental Monitor and their status.
1.3.6.1.4.1.318.1.1.10.2.3.2not-accessiblemandatory
iemStatusProbesEntry
OBJECT-TYPE
The status of the probe.
1.3.6.1.4.1.318.1.1.10.2.3.2.1not-accessiblemandatory
iemStatusProbeNumber
OBJECT-TYPE
The index of the probe.
1.3.6.1.4.1.318.1.1.10.2.3.2.1.1INTEGERread-onlymandatory
iemStatusProbeName
OBJECT-TYPE
A descriptive name for the probe set by the user.
1.3.6.1.4.1.318.1.1.10.2.3.2.1.2DisplayStringread-onlymandatory
iemStatusProbeStatus
OBJECT-TYPE
The connected status of the probe, either disconnected(1) or connected(2).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.3INTEGER {disconnected(1), connected(2)}read-onlymandatory
iemStatusProbeCurrentTemp
OBJECT-TYPE
The current temperature reading from the probe displayed in the units shown in the 'iemStatusProbeTempUnits' OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.4INTEGERread-onlymandatory
iemStatusProbeTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.10.2.3.2.1.5INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
iemStatusProbeCurrentHumid
OBJECT-TYPE
The current humidity reading from the probe in percent relative humidity.
1.3.6.1.4.1.318.1.1.10.2.3.2.1.6INTEGERread-onlymandatory
iemStatusProbeHighTempViolation
OBJECT-TYPE
The high temperature violation status of the probe temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to the high temperature threshold value, the 'iemConfigProbeHighTempThreshold' OID, and the value of the 'iemConfigProbeHighTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeHighTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.7INTEGER {noViolation(1), highTempViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeLowTempViolation
OBJECT-TYPE
The high temperature violation status of the probe temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to the low temperature threshold value, the 'iemConfigProbeLowTempThreshold' OID, and the value of the 'iemPConfigrobeLowTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeLowTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.8INTEGER {noViolation(1), lowTempViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeHighHumidViolation
OBJECT-TYPE
The high humidity violation status of the probe humidity reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the high humidity threshold value, the 'iemConfigProbeHighHumidThreshold' OID, and the value of the 'iemConfigProbeHighHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeHighHumidEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.9INTEGER {noViolation(1), highHumidViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeLowHumidViolation
OBJECT-TYPE
The low humidity violation status of the probe humidity reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the low humidity threshold value, the 'iemConfigProbeLowHumidThreshold' OID, and the value of the 'iemConfigProbeLowHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeLowHumidEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.10INTEGER {noViolation(1), lowHumidViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeMaxTempViolation
OBJECT-TYPE
The max temperature violation status of the probe temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to the maximun temperature threshold value, the 'iemConfigProbeMaxTempThreshold' OID, and the value of the 'iemConfigProbeMaxTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMaxTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.11INTEGER {noViolation(1), maxTempViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeMinTempViolation
OBJECT-TYPE
The minimum temperature violation status of the probe temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to the minimum temperature threshold value, the 'iemConfigProbeMinTempThreshold' OID, and the value of the 'iemConfigProbeMinTempEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMinTempEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.12INTEGER {noViolation(1), minTempViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeMaxHumidViolation
OBJECT-TYPE
The maximum humidity violation status of the probe humidity reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the maximum humidity threshold value, the 'iemConfigProbeMaxHumidThreshold' OID, and the value of the 'iemConfigProbeMaxHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMaxHumidEnable' OID is disabled, this OID will show disabled(3)
1.3.6.1.4.1.318.1.1.10.2.3.2.1.13INTEGER {noViolation(1), maxHumidViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeMinHumidViolation
OBJECT-TYPE
The minimum humidity violation status of the probe humidity reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the minimum humidity threshold value, the 'iemConfigProbeMinHumidThreshold' OID, and the value of the 'iemConfigProbeMinHumidEnable' OID is enabled. Otherwise it will show noViolation(1). If the 'iemConfigProbeMinHumidEnable' OID is disabled, this OID will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.2.1.14INTEGER {noViolation(1), minHumidViolation(2), disabled(3)}read-onlymandatory
iemStatusProbeLocation
OBJECT-TYPE
A descriptive location for the probe set by the user.
1.3.6.1.4.1.318.1.1.10.2.3.2.1.15DisplayStringread-onlymandatory
iemStatusContactsNumContacts
OBJECT-TYPE
The number of contacts supported on the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.2.3.3INTEGERread-onlymandatory
iemStatusContactsTable
OBJECT-TYPE
A list of contacts supported by the Environmental Monitor and their status.
1.3.6.1.4.1.318.1.1.10.2.3.4not-accessiblemandatory
iemStatusContactsEntry
OBJECT-TYPE
The status of the contact.
1.3.6.1.4.1.318.1.1.10.2.3.4.1not-accessiblemandatory
iemStatusContactNumber
OBJECT-TYPE
The index of the Environmental Monitor contact.
1.3.6.1.4.1.318.1.1.10.2.3.4.1.1INTEGERread-onlymandatory
iemStatusContactName
OBJECT-TYPE
A descriptive name for the Environmental Monitor contact set by the user, denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.2.3.4.1.2DisplayStringread-onlymandatory
iemStatusContactStatus
OBJECT-TYPE
The status of the Environmental Monitor contact. The status will show noFault(1) if the contact is in the normal state and the 'iemConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is faulted and the 'iemConfigContactEnable' OID is enabled. If the 'iemConfigContactEnable' OID is disabled, the status will show disabled(3).
1.3.6.1.4.1.318.1.1.10.2.3.4.1.3INTEGER {noFault(1), fault(2), disabled(3)}read-onlymandatory
iemStatusRelaysNumRelays
OBJECT-TYPE
The number of output relays supported on the Environmental Monitor.
1.3.6.1.4.1.318.1.1.10.2.3.6INTEGERread-onlymandatory
iemStatusRelaysTable
OBJECT-TYPE
A list of output relays supported by the Environmental Monitor and their status.
1.3.6.1.4.1.318.1.1.10.2.3.7not-accessiblemandatory
iemStatusRelaysEntry
OBJECT-TYPE
The status of the relay.
1.3.6.1.4.1.318.1.1.10.2.3.7.1not-accessiblemandatory
iemStatusRelayNumber
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.10.2.3.7.1.1INTEGERread-onlymandatory
iemStatusRelayName
OBJECT-TYPE
A descriptive name for the output relay set by the user, denoting its location or purpose.
1.3.6.1.4.1.318.1.1.10.2.3.7.1.2DisplayStringread-onlymandatory
iemStatusRelayStatus
OBJECT-TYPE
The status of the output relay, either faultState(1) or normalState(2).
1.3.6.1.4.1.318.1.1.10.2.3.7.1.3INTEGER {faultState(1), normalState(2)}read-onlymandatory
envMgtSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3
emsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.1
emsIdentEMSName
OBJECT-TYPE
A character string identifying the device.
1.3.6.1.4.1.318.1.1.10.3.1.1DisplayStringread-onlymandatory
emsIdentProductNumber
OBJECT-TYPE
A character string identifying the model number of the device. This value is set at the factory.
1.3.6.1.4.1.318.1.1.10.3.1.2DisplayStringread-onlymandatory
emsIdentFirmwareRev
OBJECT-TYPE
The firmware revision of the device.
1.3.6.1.4.1.318.1.1.10.3.1.3DisplayStringread-onlymandatory
emsIdentHardwareRev
OBJECT-TYPE
The hardware revision of the device. This value is set at the factory.
1.3.6.1.4.1.318.1.1.10.3.1.4DisplayStringread-onlymandatory
emsIdentDateOfManufacture
OBJECT-TYPE
The date when the device was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.10.3.1.5DisplayStringread-onlymandatory
emsIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the device. This value is set at the factory.
1.3.6.1.4.1.318.1.1.10.3.1.6DisplayStringread-onlymandatory
emsOutputRelayControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.2
emsOutputRelayControlTable
OBJECT-TYPE
Allows for control of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
1.3.6.1.4.1.318.1.1.10.3.2.1not-accessiblemandatory
emsOutputRelayControlEntry
OBJECT-TYPE
The output relays to control.
1.3.6.1.4.1.318.1.1.10.3.2.1.1not-accessiblemandatory
emsOutputRelayControlOutputRelayIndex
OBJECT-TYPE
The index to the output relay entry.
1.3.6.1.4.1.318.1.1.10.3.2.1.1.1INTEGERread-onlymandatory
emsOutputRelayControlOutputRelayName
OBJECT-TYPE
The name of the output relay. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.10.3.2.1.1.2DisplayStringread-onlymandatory
emsOutputRelayControlOutputRelayCommand
OBJECT-TYPE
Getting this variable will return the output relay state. If the output relay is closed, the immediateCloseEMS (1) value will be returned. If the output relay is open, the immediateOpenEMS (2) value will be returned. Setting this variable to immediateCloseEMS (1) will immediately close the relay. Setting this variable to immediateOpenEMS (2) will immediately open the relay.
1.3.6.1.4.1.318.1.1.10.3.2.1.1.3INTEGER {immediateCloseEMS(1), immediateOpenEMS(2)}read-writemandatory
emsOutletControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.3
emsOutletControlTable
OBJECT-TYPE
Allows for control of individual outlet switches. The number of entries is contained in the emsStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.10.3.3.1not-accessiblemandatory
emsOutletControlEntry
OBJECT-TYPE
The outlets to control.
1.3.6.1.4.1.318.1.1.10.3.3.1.1not-accessiblemandatory
emsOutletControlOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.10.3.3.1.1.1INTEGERread-onlymandatory
emsOutletControlOutletName
OBJECT-TYPE
The name of the outlet. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.10.3.3.1.1.2DisplayStringread-onlymandatory
emsOutletControlOutletCommand
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the immediateOnEMS (1) value will be returned. If the outlet is off, the immediateOffEMS (2) value will be returned. Setting this variable to immediateOnEMS (1) will immediately turn the outlet on. Setting this variable to immediateOffEMS (2) will immediately turn the outlet off.
1.3.6.1.4.1.318.1.1.10.3.3.1.1.3INTEGER {immediateOnEMS(1), immediateOffEMS(2)}read-writemandatory
emsSensorControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.4
emsSensorControlTable
OBJECT-TYPE
Allows for control/reset of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
1.3.6.1.4.1.318.1.1.10.3.4.1not-accessiblemandatory
emsSensorControlEntry
OBJECT-TYPE
The sensors to control/reset.
1.3.6.1.4.1.318.1.1.10.3.4.1.1not-accessiblemandatory
emsSensorControlSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.4.1.1.1INTEGERread-onlymandatory
emsSensorControlSensorSystemName
OBJECT-TYPE
The system name of the sensor. This describes the hardware system intent of this sensor.
1.3.6.1.4.1.318.1.1.10.3.4.1.1.2DisplayStringread-onlymandatory
emsSensorControlSensorUserName
OBJECT-TYPE
The name of the sensor as given by the system user.
1.3.6.1.4.1.318.1.1.10.3.4.1.1.3DisplayStringread-onlymandatory
emsSensorControlSensorCommand
OBJECT-TYPE
Getting this variable will return noCommandEMS(1). Setting this variable to resetCommandEMS(2) will issue a reset command to the sensor. Some sensors cannot be manually reset and will not be affected by this command.
1.3.6.1.4.1.318.1.1.10.3.4.1.1.4INTEGER {noCommandEMS(1), resetCommandEMS(2)}read-writemandatory
emsAlarmDeviceControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.5
emsAlarmDeviceControlTable
OBJECT-TYPE
Allows for control of individual alarm devices. Note: Some alarm devices are not controllable. The number of entries is contained in the emsStatusAlarmDeviceCount OID.
1.3.6.1.4.1.318.1.1.10.3.5.1not-accessiblemandatory
emsAlarmDeviceControlEntry
OBJECT-TYPE
The alarm devices to control.
1.3.6.1.4.1.318.1.1.10.3.5.1.1not-accessiblemandatory
emsAlarmDeviceControlDeviceIndex
OBJECT-TYPE
The index to the alarm device entry.
1.3.6.1.4.1.318.1.1.10.3.5.1.1.1INTEGERread-onlymandatory
emsAlarmDeviceControlDeviceName
OBJECT-TYPE
The name of the alarm device. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.10.3.5.1.1.2DisplayStringread-onlymandatory
emsAlarmDeviceControlDeviceCommand
OBJECT-TYPE
Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is not installed, the alarmDeviceNotInstalledEMS (3) value will be returned. Actions resulting from setting this variable are device-dependent. Setting this variable to alarmDeviceOnEMS (1) will turn that device (ex. Beacon) on. Setting this variable to alarmDeviceOffEMS (2) will turn that device off.
1.3.6.1.4.1.318.1.1.10.3.5.1.1.3INTEGER {alarmDeviceOnEMS(1), alarmDeviceOffEMS(2), alarmDeviceNotInstalledEMS(3)}read-writemandatory
emsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.6
emsConfigName
OBJECT-TYPE
The name of the device.
1.3.6.1.4.1.318.1.1.10.3.6.1DisplayStringread-writemandatory
emsConfigCheckLogLight
OBJECT-TYPE
The setting of this OID determines the level of event that will trigger the check-log light on the EMS. This is not available on the EMU2. lightDisabled (1) disables the check-log light. lightOnInformational (2) lights check-log for any event of informational severity or above. lightOnWarning (3) lights check-log for any event of warning severity or above. lightOnSevere (4) lights check-log for any event of severe severity.
1.3.6.1.4.1.318.1.1.10.3.6.2INTEGER {lightDisabled(1), lightOnInformational(2), lightOnWarning(3), lightOnSevere(4)}read-writemandatory
emsProbeConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.7
emsProbeConfigTable
OBJECT-TYPE
Allows for configuration of individual probes. The number of entries is contained in the emsStatusProbeCount OID.
1.3.6.1.4.1.318.1.1.10.3.7.1not-accessiblemandatory
emsProbeConfigEntry
OBJECT-TYPE
The probes to configure.
1.3.6.1.4.1.318.1.1.10.3.7.1.1not-accessiblemandatory
emsProbeConfigProbeIndex
OBJECT-TYPE
The index to the probe entry.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.1INTEGERread-onlymandatory
emsProbeConfigProbeName
OBJECT-TYPE
The name of the probe.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.2DisplayStringread-writemandatory
emsProbeConfigProbeHighTempThresh
OBJECT-TYPE
Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.3INTEGERread-writemandatory
emsProbeConfigProbeLowTempThresh
OBJECT-TYPE
Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.4INTEGERread-writemandatory
emsProbeConfigProbeHighHumidityThresh
OBJECT-TYPE
Probe high humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.5INTEGERread-writemandatory
emsProbeConfigProbeLowHumidityThresh
OBJECT-TYPE
Probe low humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.6INTEGERread-writemandatory
emsProbeConfigProbeMaxTempThresh
OBJECT-TYPE
Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.7INTEGERread-writemandatory
emsProbeConfigProbeMinTempThresh
OBJECT-TYPE
Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.8INTEGERread-writemandatory
emsProbeConfigProbeDeltaTemp
OBJECT-TYPE
Probe delta temperature. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.9INTEGERread-writemandatory
emsProbeConfigProbeMaxHumidityThresh
OBJECT-TYPE
Probe maximum humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.10INTEGERread-writemandatory
emsProbeConfigProbeMinHumidityThresh
OBJECT-TYPE
Probe minimum humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.11INTEGERread-writemandatory
emsProbeConfigProbeDeltaHumidity
OBJECT-TYPE
Probe delta humidity. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.12INTEGERread-writemandatory
emsProbeConfigProbeSTIncTempVariance
OBJECT-TYPE
Probe short-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.13INTEGERread-writemandatory
emsProbeConfigProbeSTIncTempTime
OBJECT-TYPE
Probe short-term increasing temperature time used for rate of change alarms. Values are represented in whole number minutes.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.14INTEGERread-writemandatory
emsProbeConfigProbeSTDecTempVariance
OBJECT-TYPE
Probe short-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.15INTEGERread-writemandatory
emsProbeConfigProbeSTDecTempTime
OBJECT-TYPE
Probe short-term decreasing temperature time used for rate of change alarms. Values are represented in whole number minutes.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.16INTEGERread-writemandatory
emsProbeConfigProbeLTIncTempVariance
OBJECT-TYPE
Probe long-term increasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.17INTEGERread-writemandatory
emsProbeConfigProbeLTIncTempTime
OBJECT-TYPE
Probe long-term increasing temperature time used for rate of change alarms. Values are represented in whole number hours.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.18INTEGERread-writemandatory
emsProbeConfigProbeLTDecTempVariance
OBJECT-TYPE
Probe long-term decreasing temperature variance used for rate of change alarms. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.7.1.1.19INTEGERread-writemandatory
emsProbeConfigProbeLTDecTempTime
OBJECT-TYPE
Probe long-term decreasing temperature time used for rate of change alarms. Values are represented in whole number hours.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.20INTEGERread-writemandatory
emsProbeConfigProbeMaxVoltThresh
OBJECT-TYPE
Probe maximum voltage threshold in Volts.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.21INTEGERread-writemandatory
emsProbeConfigProbeMinVoltThresh
OBJECT-TYPE
Probe minimum voltage threshold in Volts.
1.3.6.1.4.1.318.1.1.10.3.7.1.1.22INTEGERread-writemandatory
emsInputContactConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.8
emsInputContactConfigTable
OBJECT-TYPE
Allows for configuration of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID.
1.3.6.1.4.1.318.1.1.10.3.8.1not-accessiblemandatory
emsInputContactConfigEntry
OBJECT-TYPE
The input contacts to configure.
1.3.6.1.4.1.318.1.1.10.3.8.1.1not-accessiblemandatory
emsInputContactConfigInputContactIndex
OBJECT-TYPE
The index to the input contact entry.
1.3.6.1.4.1.318.1.1.10.3.8.1.1.1INTEGERread-onlymandatory
emsInputContactConfigInputContactName
OBJECT-TYPE
The name of the input contact.
1.3.6.1.4.1.318.1.1.10.3.8.1.1.2DisplayStringread-writemandatory
emsInputContactConfigInputContactNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the input contact
1.3.6.1.4.1.318.1.1.10.3.8.1.1.3INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)}read-writemandatory
emsOutputRelayConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.9
emsOutputRelayConfigTable
OBJECT-TYPE
Allows for configuration of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
1.3.6.1.4.1.318.1.1.10.3.9.1not-accessiblemandatory
emsOutputRelayConfigEntry
OBJECT-TYPE
The output relays to configure.
1.3.6.1.4.1.318.1.1.10.3.9.1.1not-accessiblemandatory
emsOutputRelayConfigOutputRelayIndex
OBJECT-TYPE
The index to the output relay entry.
1.3.6.1.4.1.318.1.1.10.3.9.1.1.1INTEGERread-onlymandatory
emsOutputRelayConfigOutputRelayName
OBJECT-TYPE
The name of the output relay.
1.3.6.1.4.1.318.1.1.10.3.9.1.1.2DisplayStringread-writemandatory
emsOutputRelayConfigOutputRelayNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the output relay
1.3.6.1.4.1.318.1.1.10.3.9.1.1.3INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)}read-writemandatory
emsOutletConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.10
emsOutletConfigTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the emsStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.10.3.10.1not-accessiblemandatory
emsOutletConfigEntry
OBJECT-TYPE
The outlets to configure.
1.3.6.1.4.1.318.1.1.10.3.10.1.1not-accessiblemandatory
emsOutletConfigOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.10.3.10.1.1.1INTEGERread-onlymandatory
emsOutletConfigOutletName
OBJECT-TYPE
The name of the outlet.
1.3.6.1.4.1.318.1.1.10.3.10.1.1.2DisplayStringread-writemandatory
emsOutletConfigOutletNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned. Setting this variable will change the normal state of the outlet
1.3.6.1.4.1.318.1.1.10.3.10.1.1.3INTEGER {normallyOnEMS(1), normallyOffEMS(2)}read-writemandatory
emsSensorConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.11
emsSensorConfigTable
OBJECT-TYPE
Allows for configuration of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
1.3.6.1.4.1.318.1.1.10.3.11.1not-accessiblemandatory
emsSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.3.11.1.1not-accessiblemandatory
emsSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.11.1.1.1INTEGERread-onlymandatory
emsSensorConfigSensorSystemName
OBJECT-TYPE
The system name of the sensor. This describes the hardware system intent of this sensor.
1.3.6.1.4.1.318.1.1.10.3.11.1.1.2DisplayStringread-onlymandatory
emsSensorConfigSensorUserName
OBJECT-TYPE
The name of the sensor as given by the system user.
1.3.6.1.4.1.318.1.1.10.3.11.1.1.3DisplayStringread-writemandatory
emsSensorConfigSensorNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned. Setting this variable will change the normal state of the sensor. Note: Only the AUX sensor in the EMS has a configurable Normal State
1.3.6.1.4.1.318.1.1.10.3.11.1.1.4INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)}read-writemandatory
emsSensorConfigSensorAlarmDelay
OBJECT-TYPE
The delay (in seconds) after a sensor detects an alarm condition before the condition is reported.
1.3.6.1.4.1.318.1.1.10.3.11.1.1.5INTEGERread-writemandatory
emsStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.12
emsStatusEMSName
OBJECT-TYPE
A character string identifying the device.
1.3.6.1.4.1.318.1.1.10.3.12.1DisplayStringread-onlymandatory
emsStatusCommStatus
OBJECT-TYPE
The communication status between the agent and the device. noComm(1), Communication has never been established. comm(2), Communication has been established. commLost(3), Communication was established, but was lost.
1.3.6.1.4.1.318.1.1.10.3.12.2INTEGER {noComm(1), comm(2), commLost(3)}read-onlymandatory
emsStatusProbeCount
OBJECT-TYPE
The total number of T/H probes (both local and remote) that is supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.3INTEGERread-onlymandatory
emsStatusInputContactCount
OBJECT-TYPE
The total number of Input Contacts that is supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.4INTEGERread-onlymandatory
emsStatusOutputRelayCount
OBJECT-TYPE
The total number of Output Relays that is supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.5INTEGERread-onlymandatory
emsStatusOutletCount
OBJECT-TYPE
The total number of AC Outlets that is supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.6INTEGERread-onlymandatory
emsStatusSensorCount
OBJECT-TYPE
The total number of Sensors that is supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.7INTEGERread-onlymandatory
emsStatusAlinkAruDeviceCount
OBJECT-TYPE
The total number of remote Aru's supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.8INTEGERread-onlymandatory
emsStatusAlinkProbeDeviceCount
OBJECT-TYPE
The total number of remote T/H probes supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.9INTEGERread-onlymandatory
emsStatusAlarmDeviceCount
OBJECT-TYPE
The number of alarm devices supported by this device.
1.3.6.1.4.1.318.1.1.10.3.12.10INTEGERread-onlymandatory
emsStatusSysTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.10.3.12.11INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
emsStatusCheckLogLight
OBJECT-TYPE
The status of the check-log light on the device. For the EMU2, this will always indicate lightOff(1). lightOff (1) indicates the light is off (no new log entries). lightOn (2) indicates the light is on (new log entries present).
1.3.6.1.4.1.318.1.1.10.3.12.12INTEGER {lightOff(1), lightOn(2)}read-onlymandatory
emsStatusHardwareStatus
OBJECT-TYPE
The status of the EMS hardware. This integer should be interpreted as a bit map, with each bit representing the presence or absence of a specific hardware error condition. 0 indicates there are no error conditions detected in the EMS hardware. 1 indicates a Current Limit error condition related to the Alink port. 2 indicates incorrect hardware is plugged into an EMS port. 3 indicates that both of these error conditions are present.
1.3.6.1.4.1.318.1.1.10.3.12.13INTEGERread-onlymandatory
emsProbeStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.13
emsProbeStatusTable
OBJECT-TYPE
Allows for access of individual probes. The number of entries is contained in the emsStatusProbeCount OID.
1.3.6.1.4.1.318.1.1.10.3.13.1not-accessiblemandatory
emsProbeStatusEntry
OBJECT-TYPE
The probes to access.
1.3.6.1.4.1.318.1.1.10.3.13.1.1not-accessiblemandatory
emsProbeStatusProbeIndex
OBJECT-TYPE
The index to the probe entry.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.1INTEGERread-onlymandatory
emsProbeStatusProbeName
OBJECT-TYPE
The name of the probe.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.2DisplayStringread-onlymandatory
emsProbeStatusProbeTemperature
OBJECT-TYPE
Probe temperature reading. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.13.1.1.3INTEGERread-onlymandatory
emsProbeStatusProbeHighTempThresh
OBJECT-TYPE
Probe high temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.13.1.1.4INTEGERread-onlymandatory
emsProbeStatusProbeLowTempThresh
OBJECT-TYPE
Probe low temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.13.1.1.5INTEGERread-onlymandatory
emsProbeStatusProbeHumidity
OBJECT-TYPE
Probe humidity reading. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.6INTEGERread-onlymandatory
emsProbeStatusProbeHighHumidityThresh
OBJECT-TYPE
Probe high humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.7INTEGERread-onlymandatory
emsProbeStatusProbeLowHumidityThresh
OBJECT-TYPE
Probe low humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.8INTEGERread-onlymandatory
emsProbeStatusProbeSerialNumber
OBJECT-TYPE
A label indicating the type (Local[L] or Remote[R]) and Number of the probe. For example, the first local probe would be L1 and the third remote probe would be R3.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.9DisplayStringread-onlymandatory
emsProbeStatusProbeCommStatus
OBJECT-TYPE
The state of communications to the probe. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no longer.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.10INTEGER {commsNeverDiscovered(1), commsEstablished(2), commsLost(3)}read-onlymandatory
emsProbeStatusProbeAlarmStatus
OBJECT-TYPE
The alarm status of the probe. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Short-term increasing temperature rate exceeded. 6 0x0020 Short-term decreasing temperature rate exceeded. 7 0x0040 Long-term increasing temperature rate exceeded. 8 0x0080 Long-term decreasing temperature rate exceeded. 9 0x0100 Maximum humidity exceeded. 10 0x0200 High humidity exceeded. 11 0x0400 Low humidity exceeded. 12 0x0800 Minimum humidity exceeded. 13 0x1000 Maximum voltage exceeded. 14 0x2000 Minimum voltage exceeded.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.11INTEGERread-onlymandatory
emsProbeStatusProbeMaxTempThresh
OBJECT-TYPE
Probe maximum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.13.1.1.12INTEGERread-onlymandatory
emsProbeStatusProbeMinTempThresh
OBJECT-TYPE
Probe minimum temperature threshold. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.3.13.1.1.13INTEGERread-onlymandatory
emsProbeStatusProbeMaxHumidityThresh
OBJECT-TYPE
Probe maximum humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.14INTEGERread-onlymandatory
emsProbeStatusProbeMinHumidityThresh
OBJECT-TYPE
Probe minimum humidity threshold. Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.15INTEGERread-onlymandatory
emsProbeStatusProbeVoltage
OBJECT-TYPE
Probe voltage reading. Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.16INTEGERread-onlymandatory
emsProbeStatusProbeMaxVoltThresh
OBJECT-TYPE
Probe maximum voltage threshold in Volts.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.17INTEGERread-onlymandatory
emsProbeStatusProbeMinVoltThresh
OBJECT-TYPE
Probe minimum voltage threshold in Volts.
1.3.6.1.4.1.318.1.1.10.3.13.1.1.18INTEGERread-onlymandatory
emsInputContactStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.14
emsInputContactStatusTable
OBJECT-TYPE
Allows for access of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID.
1.3.6.1.4.1.318.1.1.10.3.14.1not-accessiblemandatory
emsInputContactStatusEntry
OBJECT-TYPE
The input contacts to access.
1.3.6.1.4.1.318.1.1.10.3.14.1.1not-accessiblemandatory
emsInputContactStatusInputContactIndex
OBJECT-TYPE
The index to the input contact entry.
1.3.6.1.4.1.318.1.1.10.3.14.1.1.1INTEGERread-onlymandatory
emsInputContactStatusInputContactName
OBJECT-TYPE
The name of the input contact.
1.3.6.1.4.1.318.1.1.10.3.14.1.1.2DisplayStringread-onlymandatory
emsInputContactStatusInputContactState
OBJECT-TYPE
Getting this variable will return the state of the input contact. If the input contact is closed, the contactClosedEMS (1) value will be returned. If the input contact state is open, the contactOpenEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.14.1.1.3INTEGER {contactClosedEMS(1), contactOpenEMS(2)}read-onlymandatory
emsInputContactStatusInputContactNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the input contact. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.14.1.1.4INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)}read-onlymandatory
emsOutputRelayStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.15
emsOutputRelayStatusTable
OBJECT-TYPE
Allows for access of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
1.3.6.1.4.1.318.1.1.10.3.15.1not-accessiblemandatory
emsOutputRelayStatusEntry
OBJECT-TYPE
The output relays to access.
1.3.6.1.4.1.318.1.1.10.3.15.1.1not-accessiblemandatory
emsOutputRelayStatusOutputRelayIndex
OBJECT-TYPE
The index to the output relay entry.
1.3.6.1.4.1.318.1.1.10.3.15.1.1.1INTEGERread-onlymandatory
emsOutputRelayStatusOutputRelayName
OBJECT-TYPE
The name of the output relay.
1.3.6.1.4.1.318.1.1.10.3.15.1.1.2DisplayStringread-onlymandatory
emsOutputRelayStatusOutputRelayState
OBJECT-TYPE
Getting this variable will return the state of the output relay. If the output relay is closed, the relayClosedEMS (1) value will be returned. If the output relay is open, the relayOpenEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.15.1.1.3INTEGER {relayClosedEMS(1), relayOpenEMS(2)}read-onlymandatory
emsOutputRelayStatusOutputRelayNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the output relay. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.15.1.1.4INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)}read-onlymandatory
emsOutletStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.16
emsOutletStatusTable
OBJECT-TYPE
Allows for access of individual outlets. The number of entries is contained in the emsStatusOutletCount OID.
1.3.6.1.4.1.318.1.1.10.3.16.1not-accessiblemandatory
emsOutletStatusEntry
OBJECT-TYPE
The outlets to access.
1.3.6.1.4.1.318.1.1.10.3.16.1.1not-accessiblemandatory
emsOutletStatusOutletIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.10.3.16.1.1.1INTEGERread-onlymandatory
emsOutletStatusOutletName
OBJECT-TYPE
The name of the outlet.
1.3.6.1.4.1.318.1.1.10.3.16.1.1.2DisplayStringread-onlymandatory
emsOutletStatusOutletState
OBJECT-TYPE
Getting this variable will return the state of the outlet. If the outlet is on, the outletOnEMS (1) value will be returned. If the outlet is off, the outletOffEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.16.1.1.3INTEGER {outletOnEMS(1), outletOffEMS(2)}read-onlymandatory
emsOutletStatusOutletNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the outlet. If the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.16.1.1.4INTEGER {normallyOnEMS(1), normallyOffEMS(2)}read-onlymandatory
emsAlarmDeviceStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.17
emsAlarmDeviceStatusTable
OBJECT-TYPE
Allows for access of individual alarm devices. The number of entries is contained in the emsStatusAlarmDeviceCount OID.
1.3.6.1.4.1.318.1.1.10.3.17.1not-accessiblemandatory
emsAlarmDeviceStatusEntry
OBJECT-TYPE
The alarm devices to access.
1.3.6.1.4.1.318.1.1.10.3.17.1.1not-accessiblemandatory
emsAlarmDeviceStatusDeviceIndex
OBJECT-TYPE
The index to the alarm device entry.
1.3.6.1.4.1.318.1.1.10.3.17.1.1.1INTEGERread-onlymandatory
emsAlarmDeviceStatusDeviceName
OBJECT-TYPE
The name of the alarm device. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.10.3.17.1.1.2DisplayStringread-onlymandatory
emsAlarmDeviceStatusDeviceState
OBJECT-TYPE
Getting this variable will return the device state. If the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is not installed, the alarmDeviceNotInstalledEMS (3) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.17.1.1.3INTEGER {alarmDeviceOnEMS(1), alarmDeviceOffEMS(2), alarmDeviceNotInstalledEMS(3)}read-onlymandatory
emsSensorStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.18
emsSensorStatusTable
OBJECT-TYPE
Allows for access of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
1.3.6.1.4.1.318.1.1.10.3.18.1not-accessiblemandatory
emsSensorStatusEntry
OBJECT-TYPE
The sensors to access.
1.3.6.1.4.1.318.1.1.10.3.18.1.1not-accessiblemandatory
emsSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.18.1.1.1INTEGERread-onlymandatory
emsSensorStatusSensorSystemName
OBJECT-TYPE
The system name of the sensor. This describes the hardware system intent of this sensor.
1.3.6.1.4.1.318.1.1.10.3.18.1.1.2DisplayStringread-onlymandatory
emsSensorStatusSensorName
OBJECT-TYPE
The name of the sensor as given by the system user.
1.3.6.1.4.1.318.1.1.10.3.18.1.1.3DisplayStringread-onlymandatory
emsSensorStatusSensorState
OBJECT-TYPE
Getting this variable will return the sensor state. If the sensor is faulted, the sensorFaultedEMS (1) value will be returned. If the sensor is not faulted, the sensorOKEMS (2) value will be returned. If the sensor is not installed, the sensorNotInstalledEMS (3) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.18.1.1.4INTEGER {sensorFaultedEMS(1), sensorOKEMS(2), sensorNotInstalledEMS(3)}read-onlymandatory
emsSensorStatusSensorNormalState
OBJECT-TYPE
Getting this variable will return the normal state of the sensor. If the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be returned.
1.3.6.1.4.1.318.1.1.10.3.18.1.1.5INTEGER {normallyClosedEMS(1), normallyOpenEMS(2)}read-onlymandatory
emsSensorStatusSensorAlarmDelay
OBJECT-TYPE
The delay (in seconds) after a sensor detects an alarm condition before the condition is reported.
1.3.6.1.4.1.318.1.1.10.3.18.1.1.6INTEGERread-onlymandatory
emsInputStateSensorConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.19
emsSmokeSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.19.1not-accessiblemandatory
emsSmokeSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.3.19.1.1not-accessiblemandatory
emsSmokeSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.19.1.1.1INTEGERread-onlymandatory
emsSmokeSensorConfigSensorName
OBJECT-TYPE
The user defined name of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.3.19.1.1.2DisplayStringread-writemandatory
emsSmokeSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.3.19.1.1.3DisplayStringread-writemandatory
emsSmokeSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.19.1.1.4INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
emsVibrationSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.19.2not-accessiblemandatory
emsVibrationSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.3.19.2.1not-accessiblemandatory
emsVibrationSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.19.2.1.1INTEGERread-onlymandatory
emsVibrationSensorConfigSensorName
OBJECT-TYPE
The user defined name of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.3.19.2.1.2DisplayStringread-writemandatory
emsVibrationSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.3.19.2.1.3DisplayStringread-writemandatory
emsVibrationSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.19.2.1.4INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
emsFluidSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.19.3not-accessiblemandatory
emsFluidSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.3.19.3.1not-accessiblemandatory
emsFluidSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.19.3.1.1INTEGERread-onlymandatory
emsFluidSensorConfigSensorName
OBJECT-TYPE
The user defined name of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.3.19.3.1.2DisplayStringread-writemandatory
emsFluidSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.3.19.3.1.3DisplayStringread-writemandatory
emsFluidSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.19.3.1.4INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
emsDoorSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.19.4not-accessiblemandatory
emsDoorSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.3.19.4.1not-accessiblemandatory
emsDoorSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.19.4.1.1INTEGERread-onlymandatory
emsDoorSensorConfigSensorName
OBJECT-TYPE
The user defined name of the door sensor.
1.3.6.1.4.1.318.1.1.10.3.19.4.1.2DisplayStringread-writemandatory
emsDoorSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the door sensor.
1.3.6.1.4.1.318.1.1.10.3.19.4.1.3DisplayStringread-writemandatory
emsDoorSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.19.4.1.4INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
emsInputStateSensorStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.3.20
emsSmokeSensorStatusTableSize
OBJECT-TYPE
The number of entries in the emsSmokeSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.3.20.1INTEGERread-onlymandatory
emsSmokeSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.20.2not-accessiblemandatory
emsSmokeSensorStatusEntry
OBJECT-TYPE
The sensor to access.
1.3.6.1.4.1.318.1.1.10.3.20.2.1not-accessiblemandatory
emsSmokeSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.20.2.1.1INTEGERread-onlymandatory
emsSmokeSensorStatusSensorName
OBJECT-TYPE
The user defined name of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.3.20.2.1.2DisplayStringread-onlymandatory
emsSmokeSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.3.20.2.1.3DisplayStringread-onlymandatory
emsSmokeSensorStatusSensorState
OBJECT-TYPE
The state of the smoke sensor. smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.3.20.2.1.4INTEGER {smokeDetected(1), noSmoke(2), unknown(3)}read-onlymandatory
emsSmokeSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.20.2.1.5INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
emsSmokeSensorCommStatus
OBJECT-TYPE
The communication status of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.3.20.2.1.6INTEGER {commOK(1), commLost(2)}read-onlymandatory
emsVibrationSensorStatusTableSize
OBJECT-TYPE
The number of entries in the emsVibrationSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.3.20.3INTEGERread-onlymandatory
emsVibrationSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.20.4not-accessiblemandatory
emsVibrationSensorStatusEntry
OBJECT-TYPE
The sensor to access.
1.3.6.1.4.1.318.1.1.10.3.20.4.1not-accessiblemandatory
emsVibrationSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.20.4.1.1INTEGERread-onlymandatory
emsVibrationSensorStatusSensorName
OBJECT-TYPE
The user defined name of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.3.20.4.1.2DisplayStringread-onlymandatory
emsVibrationSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.3.20.4.1.3DisplayStringread-onlymandatory
emsVibrationSensorStatusSensorState
OBJECT-TYPE
The state of the vibration sensor. vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.3.20.4.1.4INTEGER {vibrationDetected(1), noVibration(2), unknown(3)}read-onlymandatory
emsVibrationSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.20.4.1.5INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
emsVibrationSensorCommStatus
OBJECT-TYPE
The communication status of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.3.20.4.1.6INTEGER {commOK(1), commLost(2)}read-onlymandatory
emsFluidSensorStatusTableSize
OBJECT-TYPE
The number of entries in the emsFluidSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.3.20.5INTEGERread-onlymandatory
emsFluidSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.20.6not-accessiblemandatory
emsFluidSensorStatusEntry
OBJECT-TYPE
The sensors to access.
1.3.6.1.4.1.318.1.1.10.3.20.6.1not-accessiblemandatory
emsFluidSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.20.6.1.1INTEGERread-onlymandatory
emsFluidSensorStatusSensorName
OBJECT-TYPE
The user defined name of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.3.20.6.1.2DisplayStringread-onlymandatory
emsFluidSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.3.20.6.1.3DisplayStringread-onlymandatory
emsFluidSensorStatusSensorState
OBJECT-TYPE
The state of the fluid sensor. fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.3.20.6.1.4INTEGER {fluidDetected(1), noFluid(2), unknown(3)}read-onlymandatory
emsFluidSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.20.6.1.5INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
emsFluidSensorCommStatus
OBJECT-TYPE
The communication status of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.3.20.6.1.6INTEGER {commOK(1), commLost(2)}read-onlymandatory
emsDoorSensorStatusTableSize
OBJECT-TYPE
The number of entries in the emsDoorSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.3.20.7INTEGERread-onlymandatory
emsDoorSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.3.20.8not-accessiblemandatory
emsDoorSensorStatusEntry
OBJECT-TYPE
The sensor to access.
1.3.6.1.4.1.318.1.1.10.3.20.8.1not-accessiblemandatory
emsDoorSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.3.20.8.1.1INTEGERread-onlymandatory
emsDoorSensorStatusSensorName
OBJECT-TYPE
The user defined name of the door sensor.
1.3.6.1.4.1.318.1.1.10.3.20.8.1.2DisplayStringread-onlymandatory
emsDoorSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the door sensor.
1.3.6.1.4.1.318.1.1.10.3.20.8.1.3DisplayStringread-onlymandatory
emsDoorSensorStatusSensorState
OBJECT-TYPE
The state of the door sensor. open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.3.20.8.1.4INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
emsDoorSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.3.20.8.1.5INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
emsDoorSensorCommStatus
OBJECT-TYPE
The communication status of the door sensor.
1.3.6.1.4.1.318.1.1.10.3.20.8.1.6INTEGER {commOK(1), commLost(2)}read-onlymandatory
modEnvMgr
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4
memModules
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.1
memModulesStatusTableSize
OBJECT-TYPE
The number of entries in the memModulesStatusTable.
1.3.6.1.4.1.318.1.1.10.4.1.1INTEGERread-onlymandatory
memModulesStatusTable
OBJECT-TYPE
Allows for getting status information from the modules attached to the system.
1.3.6.1.4.1.318.1.1.10.4.1.2not-accessiblemandatory
memModulesStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.1.2.1not-accessiblemandatory
memModulesStatusModuleNumber
OBJECT-TYPE
The module number.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.1INTEGERread-onlymandatory
memModulesStatusModuleName
OBJECT-TYPE
The module name.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.2DisplayStringread-onlymandatory
memModulesStatusModuleLocation
OBJECT-TYPE
The location of the module.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.3DisplayStringread-onlymandatory
memModulesStatusModelNumber
OBJECT-TYPE
The model number of the module.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.4DisplayStringread-onlymandatory
memModulesStatusSerialNumber
OBJECT-TYPE
The serial number of the module.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.5DisplayStringread-onlymandatory
memModulesStatusFirmwareRev
OBJECT-TYPE
The firmware revision of the module.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.6DisplayStringread-onlymandatory
memModulesStatusHardwareRev
OBJECT-TYPE
The hardware revision.
1.3.6.1.4.1.318.1.1.10.4.1.2.1.7DisplayStringread-onlymandatory
memModulesConfigTableSize
OBJECT-TYPE
The number of entries in the memModulesConfigTable.
1.3.6.1.4.1.318.1.1.10.4.1.3INTEGERread-onlymandatory
memModulesConfigTable
OBJECT-TYPE
Allows for getting status information from the modules attached to the system.
1.3.6.1.4.1.318.1.1.10.4.1.4not-accessiblemandatory
memModulesConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.1.4.1not-accessiblemandatory
memModulesConfigModuleNumber
OBJECT-TYPE
The module number.
1.3.6.1.4.1.318.1.1.10.4.1.4.1.1INTEGERread-onlymandatory
memModulesConfigModuleName
OBJECT-TYPE
The module name.
1.3.6.1.4.1.318.1.1.10.4.1.4.1.2DisplayStringread-writemandatory
memModulesConfigModuleLocation
OBJECT-TYPE
The location of the module.
1.3.6.1.4.1.318.1.1.10.4.1.4.1.3DisplayStringread-writemandatory
memSensors
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.2
memSensorsStatusSysTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.10.4.2.1INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
memSensorsStatusTableSize
OBJECT-TYPE
The number of entries in the memSensorsStatusTable.
1.3.6.1.4.1.318.1.1.10.4.2.2INTEGERread-onlymandatory
memSensorsStatusTable
OBJECT-TYPE
Allows for getting sensor status information.
1.3.6.1.4.1.318.1.1.10.4.2.3not-accessiblemandatory
memSensorsStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.2.3.1not-accessiblemandatory
memSensorsStatusModuleNumber
OBJECT-TYPE
The number of the module that the sensor is attached to.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.1INTEGERread-onlymandatory
memSensorsStatusSensorNumber
OBJECT-TYPE
The number of this sensor on the module.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.2INTEGERread-onlymandatory
memSensorsStatusSensorName
OBJECT-TYPE
The sensor name.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.3DisplayStringread-onlymandatory
memSensorsStatusSensorLocation
OBJECT-TYPE
The location of the sensor.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.4DisplayStringread-onlymandatory
memSensorsTemperature
OBJECT-TYPE
The sensor's current temperature reading. Units are displayed in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.4.2.3.1.5INTEGERread-onlymandatory
memSensorsHumidity
OBJECT-TYPE
The current humidity reading from the sensor.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.6INTEGERread-onlymandatory
memSensorsCommStatus
OBJECT-TYPE
The communications status of the sensor.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.7INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
memSensorsAlarmStatus
OBJECT-TYPE
The alarm status of the sensor. memWarning is not applicable to voltage sensor.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.8INTEGER {memNormal(1), memWarning(2), memCritical(3)}read-onlymandatory
memSensorsTemperatureHighPrec
OBJECT-TYPE
The current temperature is displayed in tenths of degrees in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.4.2.3.1.9INTEGERread-onlymandatory
memSensorsVoltage
OBJECT-TYPE
The sensor's current voltage reading. Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.4.2.3.1.10INTEGERread-onlymandatory
memSensorsConfigTableSize
OBJECT-TYPE
The number of entries in the memSensorsConfigTable.
1.3.6.1.4.1.318.1.1.10.4.2.4INTEGERread-onlymandatory
memSensorsConfigTable
OBJECT-TYPE
Allows for getting configuration information from sensors attached to the system.
1.3.6.1.4.1.318.1.1.10.4.2.5not-accessiblemandatory
memSensorsConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.2.5.1not-accessiblemandatory
memSensorsConfigModuleNumber
OBJECT-TYPE
The number of the module that the sensor is attached to.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.1INTEGERread-onlymandatory
memSensorsConfigSensorNumber
OBJECT-TYPE
The number of this sensor on the module.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.2INTEGERread-onlymandatory
memSensorsName
OBJECT-TYPE
A descriptive name for the sensor.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.3DisplayStringread-writemandatory
memSensorsLocation
OBJECT-TYPE
The location of the sensor.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.4DisplayStringread-writemandatory
memSensorsAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation on this sensor.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.5INTEGER {disabled(1), enabled(2)}read-writemandatory
memSensorsTempMaxThresh
OBJECT-TYPE
The temperature at which the MEM will generate a maximum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.6INTEGERread-writemandatory
memSensorsTempHighThresh
OBJECT-TYPE
The temperature at which the MEM will generate a high temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.7INTEGERread-writemandatory
memSensorsTempLowThresh
OBJECT-TYPE
The temperature at which the MEM will generate a low temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.8INTEGERread-writemandatory
memSensorsTempMinThresh
OBJECT-TYPE
The temperature at which the MEM will generate a minimum temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.9INTEGERread-writemandatory
memSensorsTempThreshHysteresis
OBJECT-TYPE
The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.10INTEGERread-writemandatory
memSensorsTempShortDecRateThreshValue
OBJECT-TYPE
The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.11INTEGERread-writemandatory
memSensorsTempShortDecRateThreshTime
OBJECT-TYPE
The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.12INTEGERread-writemandatory
memSensorsTempShortIncRateThreshValue
OBJECT-TYPE
The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.13INTEGERread-writemandatory
memSensorsTempShortIncRateThreshTime
OBJECT-TYPE
The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.14INTEGERread-writemandatory
memSensorsTempLongDecRateThreshValue
OBJECT-TYPE
The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.15INTEGERread-writemandatory
memSensorsTempLongDecRateThreshTime
OBJECT-TYPE
The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.16INTEGERread-writemandatory
memSensorsTempLongIncRateThreshValue
OBJECT-TYPE
The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.17INTEGERread-writemandatory
memSensorsTempLongIncRateThreshTime
OBJECT-TYPE
The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.18INTEGERread-writemandatory
memSensorsHumidityMaxThresh
OBJECT-TYPE
The humidity at which the maximum humidity threshold alarm will be generated.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.19INTEGERread-writemandatory
memSensorsHumidityHighThresh
OBJECT-TYPE
The humidity at which the high humidity threshold alarm will be generated.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.20INTEGERread-writemandatory
memSensorsHumidityLowThresh
OBJECT-TYPE
The humidity at which the low humidity threshold alarm will be generated.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.21INTEGERread-writemandatory
memSensorsHumidityMinThresh
OBJECT-TYPE
The humidity at which the minimum humidity threshold alarm will be generated.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.22INTEGERread-writemandatory
memSensorsHumidityThreshHysteresis
OBJECT-TYPE
The change in humidity required to cause an active humidity alarm to change to the inactive state.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.23INTEGERread-writemandatory
memSensorsVoltMaxThresh
OBJECT-TYPE
The voltage at which the MEM will generate a maximum voltage threshold violation alarm on this sensor.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.24INTEGERread-writemandatory
memSensorsVoltMinThresh
OBJECT-TYPE
The voltage at which the MEM will generate a minimum voltage threshold violation alarm on this sensor.
1.3.6.1.4.1.318.1.1.10.4.2.5.1.25INTEGERread-writemandatory
memInputs
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.3
memInputsStatusTableSize
OBJECT-TYPE
The number of entries in the memInputsStatusTable.
1.3.6.1.4.1.318.1.1.10.4.3.1INTEGERread-onlymandatory
memInputsStatusTable
OBJECT-TYPE
Allows for getting input status information.
1.3.6.1.4.1.318.1.1.10.4.3.2not-accessiblemandatory
memInputsStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.3.2.1not-accessiblemandatory
memInputsStatusModuleNumber
OBJECT-TYPE
The number of the module that the input is attached to.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.1INTEGERread-onlymandatory
memInputsStatusInputNumber
OBJECT-TYPE
The number of this input on the module.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.2INTEGERread-onlymandatory
memInputsStatusInputName
OBJECT-TYPE
The input name.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.3DisplayStringread-onlymandatory
memInputsStatusInputLocation
OBJECT-TYPE
The location of the input.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.4DisplayStringread-onlymandatory
memInputsStatusCurrentState
OBJECT-TYPE
The current state of the input. This OID will return inputStateNotAplicable(4) for analog input types.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.5INTEGER {inputClosedHighMEM(1), inputOpenLowMEM(2), inputDisabled(3), inputStateNotApplicable(4)}read-onlymandatory
memInputsStatusCurrentAnalogValue
OBJECT-TYPE
The current analog value of the input in the units defined by the user.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.6DisplayStringread-onlymandatory
memInputsStatusAlarmStatus
OBJECT-TYPE
The alarm status of the input.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.7INTEGER {memNormal(1), memWarning(2), memCritical(3)}read-onlymandatory
memInputsCommStatus
OBJECT-TYPE
The communications status of the input. This OID is only supported by NBRK0200.
1.3.6.1.4.1.318.1.1.10.4.3.2.1.8INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
memInputsConfigTableSize
OBJECT-TYPE
The number of entries in the memInputsConfigTable.
1.3.6.1.4.1.318.1.1.10.4.3.3INTEGERread-onlymandatory
memInputsConfigTable
OBJECT-TYPE
Allows for getting input configuration information.
1.3.6.1.4.1.318.1.1.10.4.3.4not-accessiblemandatory
memInputsConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.3.4.1not-accessiblemandatory
memInputsConfigModuleNumber
OBJECT-TYPE
The number of the module that the input is attached to.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.1INTEGERread-onlymandatory
memInputsConfigInputNumber
OBJECT-TYPE
The number of this input on the module.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.2INTEGERread-onlymandatory
memInputName
OBJECT-TYPE
The name of the input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.3DisplayStringread-writemandatory
memInputLocation
OBJECT-TYPE
The location of the input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.4DisplayStringread-writemandatory
memInputType
OBJECT-TYPE
The type of input this contact will take.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.5INTEGER {noConnection(1), dryContact(2), digital(3), analogmAmps(4), analogVolts(5)}read-writemandatory
memInputAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation on this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
memInputNormalState
OBJECT-TYPE
Defines the normal (no alarm) state of the input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.7INTEGER {inputClosedHighMEM(1), inputOpenLowMEM(2), inputDisabled(3), inputStateNotApplicable(4)}read-writemandatory
memInputAbnormalSeverity
OBJECT-TYPE
Defines the severity of the event that is associated with the abnormal state of the input. This OID will return inputSeverityNotApplicable(4) for analog input types.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.8INTEGER {inputSeverityinformational(1), inputSeveritywarning(2), inputSeveritysevere(3), inputSeverityNotApplicable(4)}read-writemandatory
memInputNumberCalibrationPoints
OBJECT-TYPE
The number of calibration points that are required for this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.9INTEGERread-writemandatory
memInputAnalogCalibrationPoint1
OBJECT-TYPE
The electrical value that the input sensor will measure at the first calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
1.3.6.1.4.1.318.1.1.10.4.3.4.1.10DisplayStringread-writemandatory
memInputAnalogCalibrationPoint2
OBJECT-TYPE
The electrical value that the input sensor will measure at the second calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
1.3.6.1.4.1.318.1.1.10.4.3.4.1.11DisplayStringread-writemandatory
memInputAnalogCalibrationPoint3
OBJECT-TYPE
The electrical value that the input sensor will measure at the third calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
1.3.6.1.4.1.318.1.1.10.4.3.4.1.12DisplayStringread-writemandatory
memInputAnalogCalibrationPoint4
OBJECT-TYPE
The electrical value that the input sensor will measure at the fourth calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
1.3.6.1.4.1.318.1.1.10.4.3.4.1.13DisplayStringread-writemandatory
memInputAnalogCalibrationPoint5
OBJECT-TYPE
The electrical value that the input sensor will measure at the fifth calibration point. This OID is relevant only for inputs configured as analog type (ma or V).
1.3.6.1.4.1.318.1.1.10.4.3.4.1.14DisplayStringread-writemandatory
memInputAnalogCalibrationPoint1Value
OBJECT-TYPE
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the first calibration point.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.15DisplayStringread-writemandatory
memInputAnalogCalibrationPoint2Value
OBJECT-TYPE
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the second calibration point.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.16DisplayStringread-writemandatory
memInputAnalogCalibrationPoint3Value
OBJECT-TYPE
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the third calibration point.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.17DisplayStringread-writemandatory
memInputAnalogCalibrationPoint4Value
OBJECT-TYPE
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fourth calibration point.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.18DisplayStringread-writemandatory
memInputAnalogCalibrationPoint5Value
OBJECT-TYPE
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the fifth calibration point.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.19DisplayStringread-writemandatory
memInputAnalogMeasurementUnits
OBJECT-TYPE
The units of measure to be used for this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.20DisplayStringread-writemandatory
memInputAnalogMaxThresh
OBJECT-TYPE
The input value at which a maximum threshold violation alarm will be generated on this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.21DisplayStringread-writemandatory
memInputAnalogHighThresh
OBJECT-TYPE
The input value at which a high threshold violation alarm will be generated on this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.22DisplayStringread-writemandatory
memInputAnalogLowThresh
OBJECT-TYPE
The input value at which a low threshold violation alarm will be generated on this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.23DisplayStringread-writemandatory
memInputAnalogMinThresh
OBJECT-TYPE
The input value at which a minimum threshold violation alarm will be generated on this input.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.24DisplayStringread-writemandatory
memInputAnalogThreshHysteresis
OBJECT-TYPE
The change in value required to cause an alarm on this input to change from active to inactive.
1.3.6.1.4.1.318.1.1.10.4.3.4.1.25DisplayStringread-writemandatory
memOutputs
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.4
memOutputStatusTableSize
OBJECT-TYPE
The number of entries in the memOutputStatusTable.
1.3.6.1.4.1.318.1.1.10.4.4.1INTEGERread-onlymandatory
memOutputStatusTable
OBJECT-TYPE
Allows for getting output status information.
1.3.6.1.4.1.318.1.1.10.4.4.2not-accessiblemandatory
memOutputStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.4.2.1not-accessiblemandatory
memOutputStatusModuleNumber
OBJECT-TYPE
The number of the module that the output is attached to.
1.3.6.1.4.1.318.1.1.10.4.4.2.1.1INTEGERread-onlymandatory
memOutputStatusOutputNumber
OBJECT-TYPE
The number of this output on the module.
1.3.6.1.4.1.318.1.1.10.4.4.2.1.2INTEGERread-onlymandatory
memOutputStatusOutputName
OBJECT-TYPE
The output name.
1.3.6.1.4.1.318.1.1.10.4.4.2.1.3DisplayStringread-onlymandatory
memOutputStatusOutputLocation
OBJECT-TYPE
The location of the output.
1.3.6.1.4.1.318.1.1.10.4.4.2.1.4DisplayStringread-onlymandatory
memOutputStatusCurrentState
OBJECT-TYPE
The state of the output.
1.3.6.1.4.1.318.1.1.10.4.4.2.1.5INTEGER {memOutputClosed(1), memOutputOpen(2)}read-onlymandatory
memOutputStatusAlarmState
OBJECT-TYPE
The alarm state of the output.
1.3.6.1.4.1.318.1.1.10.4.4.2.1.6INTEGER {memOutputNormal(1), memOutputAbnormal(2)}read-onlymandatory
memOutputConfigTableSize
OBJECT-TYPE
The number of entries in the memOutputConfigTable.
1.3.6.1.4.1.318.1.1.10.4.4.3INTEGERread-onlymandatory
memOutputConfigTable
OBJECT-TYPE
Allows for getting output configuration information.
1.3.6.1.4.1.318.1.1.10.4.4.4not-accessiblemandatory
memOutputConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.4.4.1not-accessiblemandatory
memOutputConfigModuleNumber
OBJECT-TYPE
The number of the module that the output is attached to.
1.3.6.1.4.1.318.1.1.10.4.4.4.1.1INTEGERread-onlymandatory
memOutputConfigOutputNumber
OBJECT-TYPE
The number of this output on the module.
1.3.6.1.4.1.318.1.1.10.4.4.4.1.2INTEGERread-onlymandatory
memOutputName
OBJECT-TYPE
The name of the output.
1.3.6.1.4.1.318.1.1.10.4.4.4.1.3DisplayStringread-writemandatory
memOutputLocation
OBJECT-TYPE
The location of the output.
1.3.6.1.4.1.318.1.1.10.4.4.4.1.4DisplayStringread-writemandatory
memOutputNormalState
OBJECT-TYPE
The state of the output that will not generate an alarm.
1.3.6.1.4.1.318.1.1.10.4.4.4.1.5INTEGER {memOutputClosed(1), memOutputOpen(2)}read-writemandatory
memOutputAction
OBJECT-TYPE
Manual control actions for the output. SNMP get command will return the state of the output, SNMP set of this OID controls the output.
1.3.6.1.4.1.318.1.1.10.4.4.4.1.6INTEGER {memActionClose(1), memActionOpen(2)}read-writemandatory
memOutlets
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.5
memOutletStatusTableSize
OBJECT-TYPE
The number of entries in the memOutletStatusTable.
1.3.6.1.4.1.318.1.1.10.4.5.1INTEGERread-onlymandatory
memOutletStatusTable
OBJECT-TYPE
Allows for getting outlet status information.
1.3.6.1.4.1.318.1.1.10.4.5.2not-accessiblemandatory
memOutletStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.5.2.1not-accessiblemandatory
memOutletStatusModuleNumber
OBJECT-TYPE
The number of the module that the outlet is attached to.
1.3.6.1.4.1.318.1.1.10.4.5.2.1.1INTEGERread-onlymandatory
memOutletStatusOutletNumber
OBJECT-TYPE
The number of this outlet on the module.
1.3.6.1.4.1.318.1.1.10.4.5.2.1.2INTEGERread-onlymandatory
memOutletStatusOutletName
OBJECT-TYPE
The outlet name.
1.3.6.1.4.1.318.1.1.10.4.5.2.1.3DisplayStringread-onlymandatory
memOutletStatusOutletLocation
OBJECT-TYPE
The location of the outlet.
1.3.6.1.4.1.318.1.1.10.4.5.2.1.4DisplayStringread-onlymandatory
memOutletStatusCurrentState
OBJECT-TYPE
The state of the outlet.
1.3.6.1.4.1.318.1.1.10.4.5.2.1.5INTEGER {off(1), on(2)}read-onlymandatory
memOutletStatusAlarmState
OBJECT-TYPE
The alarm state of the outlet.
1.3.6.1.4.1.318.1.1.10.4.5.2.1.6INTEGER {memOutletNormal(1), memOutletAbnormal(2)}read-onlymandatory
memOutletConfigTableSize
OBJECT-TYPE
The number of entries in the memOutletConfigTable.
1.3.6.1.4.1.318.1.1.10.4.5.3INTEGERread-onlymandatory
memOutletConfigTable
OBJECT-TYPE
Allows for getting outlet configuration information.
1.3.6.1.4.1.318.1.1.10.4.5.4not-accessiblemandatory
memOutletConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.5.4.1not-accessiblemandatory
memOutletConfigModuleNumber
OBJECT-TYPE
The number of the module that the Outlet is attached to.
1.3.6.1.4.1.318.1.1.10.4.5.4.1.1INTEGERread-onlymandatory
memOutletConfigOutletNumber
OBJECT-TYPE
The number of this Outlet on the module.
1.3.6.1.4.1.318.1.1.10.4.5.4.1.2INTEGERread-onlymandatory
memOutletName
OBJECT-TYPE
The name of the Outlet.
1.3.6.1.4.1.318.1.1.10.4.5.4.1.3DisplayStringread-writemandatory
memOutletLocation
OBJECT-TYPE
The location of the Outlet.
1.3.6.1.4.1.318.1.1.10.4.5.4.1.4DisplayStringread-writemandatory
memOutletNormalState
OBJECT-TYPE
The state of the Outlet that will not generate an alarm.
1.3.6.1.4.1.318.1.1.10.4.5.4.1.5INTEGER {off(1), on(2)}read-writemandatory
memOutletAction
OBJECT-TYPE
Manual control actions for the Outlet. Get displays state of outlet, set controls outlet.
1.3.6.1.4.1.318.1.1.10.4.5.4.1.6INTEGER {turnOff(1), turnOn(2)}read-writemandatory
memBeacons
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.6
memBeaconStatusTableSize
OBJECT-TYPE
The number of entries in the memBeaconStatusTable.
1.3.6.1.4.1.318.1.1.10.4.6.1INTEGERread-onlymandatory
memBeaconStatusTable
OBJECT-TYPE
Allows for getting beacon status information.
1.3.6.1.4.1.318.1.1.10.4.6.2not-accessiblemandatory
memBeaconStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.6.2.1not-accessiblemandatory
memBeaconStatusModuleNumber
OBJECT-TYPE
The number of the module that the beacon is attached to.
1.3.6.1.4.1.318.1.1.10.4.6.2.1.1INTEGERread-onlymandatory
memBeaconStatusBeaconNumber
OBJECT-TYPE
The number of this beacon on the module.
1.3.6.1.4.1.318.1.1.10.4.6.2.1.2INTEGERread-onlymandatory
memBeaconStatusBeaconName
OBJECT-TYPE
The beacon name.
1.3.6.1.4.1.318.1.1.10.4.6.2.1.3DisplayStringread-onlymandatory
memBeaconStatusBeaconLocation
OBJECT-TYPE
The location of the beacon.
1.3.6.1.4.1.318.1.1.10.4.6.2.1.4DisplayStringread-onlymandatory
memBeaconStatusCurrentState
OBJECT-TYPE
The state of the beacon.
1.3.6.1.4.1.318.1.1.10.4.6.2.1.5INTEGER {off(1), on(2)}read-onlymandatory
memBeaconStatusAlarmState
OBJECT-TYPE
The alarm state of the beacon.
1.3.6.1.4.1.318.1.1.10.4.6.2.1.6INTEGER {memBeaconNormal(1), memBeaconAbnormal(2)}read-onlymandatory
memBeaconConfigTableSize
OBJECT-TYPE
The number of entries in the memBeaconConfigTable.
1.3.6.1.4.1.318.1.1.10.4.6.3INTEGERread-onlymandatory
memBeaconConfigTable
OBJECT-TYPE
Allows for getting beacon configuration information.
1.3.6.1.4.1.318.1.1.10.4.6.4not-accessiblemandatory
memBeaconConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.10.4.6.4.1not-accessiblemandatory
memBeaconConfigModuleNumber
OBJECT-TYPE
The number of the module that the beacon is attached to.
1.3.6.1.4.1.318.1.1.10.4.6.4.1.1INTEGERread-onlymandatory
memBeaconConfigBeaconNumber
OBJECT-TYPE
The number of this beacon on the module.
1.3.6.1.4.1.318.1.1.10.4.6.4.1.2INTEGERread-onlymandatory
memBeaconConfigName
OBJECT-TYPE
The name of the beacon.
1.3.6.1.4.1.318.1.1.10.4.6.4.1.3DisplayStringread-writemandatory
memBeaconConfigLocation
OBJECT-TYPE
The location of the beacon.
1.3.6.1.4.1.318.1.1.10.4.6.4.1.4DisplayStringread-writemandatory
memBeaconAction
OBJECT-TYPE
Control action (on/off) for the beacon. Setting this OID will turn the beacon on/off. Getting this OID will respond with the current state.
1.3.6.1.4.1.318.1.1.10.4.6.4.1.5INTEGER {turnOff(1), turnOn(2)}read-writemandatory
memInputStateSensors
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.4.7
memSmokeSensorStatusTableSize
OBJECT-TYPE
The number of entries in the memSmokeSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.4.7.1INTEGERread-onlymandatory
memSmokeSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.2not-accessiblemandatory
memSmokeSensorStatusEntry
OBJECT-TYPE
The sensor to access.
1.3.6.1.4.1.318.1.1.10.4.7.2.1not-accessiblemandatory
memSmokeSensorStatusModuleIndex
OBJECT-TYPE
The index to the module entry.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.1INTEGERread-onlymandatory
memSmokeSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.2INTEGERread-onlymandatory
memSmokeSensorStatusSensorName
OBJECT-TYPE
The user defined name of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.3DisplayStringread-onlymandatory
memSmokeSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.4DisplayStringread-onlymandatory
memSmokeSensorStatusSensorState
OBJECT-TYPE
The state of the smoke sensor. smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.5INTEGER {smokeDetected(1), noSmoke(2), unknown(3)}read-onlymandatory
memSmokeSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.2.1.6INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
memSmokeStatusAlarmStatus
OBJECT-TYPE
The alarm status of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.7INTEGER {memNormal(1), memWarning(2), memCritical(3)}read-onlymandatory
memSmokeSensorCommStatus
OBJECT-TYPE
The communication status of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.4.7.2.1.8INTEGER {commOK(1), commLost(2)}read-onlymandatory
memVibrationSensorStatusTableSize
OBJECT-TYPE
The number of entries in the memVibrationSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.4.7.3INTEGERread-onlymandatory
memVibrationSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.4not-accessiblemandatory
memVibrationSensorStatusEntry
OBJECT-TYPE
The sensors to access.
1.3.6.1.4.1.318.1.1.10.4.7.4.1not-accessiblemandatory
memVibrationSensorStatusModuleIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.1INTEGERread-onlymandatory
memVibrationSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.2INTEGERread-onlymandatory
memVibrationSensorStatusSensorName
OBJECT-TYPE
The user defined name of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.3DisplayStringread-onlymandatory
memVibrationSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.4DisplayStringread-onlymandatory
memVibrationSensorStatusSensorState
OBJECT-TYPE
The state of the vibration sensor. vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.5INTEGER {vibrationDetected(1), noVibration(2), unknown(3)}read-onlymandatory
memVibrationSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.4.1.6INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
memVibrationStatusAlarmStatus
OBJECT-TYPE
The alarm status of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.7INTEGER {memNormal(1), memWarning(2), memCritical(3)}read-onlymandatory
memVibrationSensorCommStatus
OBJECT-TYPE
The communication status of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.4.7.4.1.8INTEGER {commOK(1), commLost(2)}read-onlymandatory
memFluidSensorStatusTableSize
OBJECT-TYPE
The number of entries in the memFluidSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.4.7.5INTEGERread-onlymandatory
memFluidSensorStatusTable
OBJECT-TYPE
Allows for access of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.6not-accessiblemandatory
memFluidSensorStatusEntry
OBJECT-TYPE
The sensor to access.
1.3.6.1.4.1.318.1.1.10.4.7.6.1not-accessiblemandatory
memFluidSensorStatusModuleIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.1INTEGERread-onlymandatory
memFluidSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.2INTEGERread-onlymandatory
memFluidSensorStatusSensorName
OBJECT-TYPE
The user defined name of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.3DisplayStringread-onlymandatory
memFluidSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.4DisplayStringread-onlymandatory
memFluidSensorStatusSensorState
OBJECT-TYPE
The state of the fluid sensor. fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.5INTEGER {fluidDetected(1), noFluid(2), unknown(3)}read-onlymandatory
memFluidSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.6.1.6INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
memFluidStatusAlarmStatus
OBJECT-TYPE
The alarm status of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.7INTEGER {memNormal(1), memWarning(2), memCritical(3)}read-onlymandatory
memFluidSensorCommStatus
OBJECT-TYPE
The communication status of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.4.7.6.1.8INTEGER {commOK(1), commLost(2)}read-onlymandatory
memDoorSensorStatusTableSize
OBJECT-TYPE
The number of entries in the memDoorSensorStatusTable.
1.3.6.1.4.1.318.1.1.10.4.7.7INTEGERread-onlymandatory
memDoorSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.8not-accessiblemandatory
memDoorSensorStatusEntry
OBJECT-TYPE
The sensor to access.
1.3.6.1.4.1.318.1.1.10.4.7.8.1not-accessiblemandatory
memDoorSensorStatusModuleIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.1INTEGERread-onlymandatory
memDoorSensorStatusSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.2INTEGERread-onlymandatory
memDoorSensorStatusSensorName
OBJECT-TYPE
The user defined name of the door sensor.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.3DisplayStringread-onlymandatory
memDoorSensorStatusSensorLocation
OBJECT-TYPE
The user defined location of the door sensor.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.4DisplayStringread-onlymandatory
memDoorSensorStatusSensorState
OBJECT-TYPE
The state of the door sensor. open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.5INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
memDoorSensorStatusSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.8.1.6INTEGER {critical(1), warning(2), informational(3)}read-onlymandatory
memDoorStatusAlarmStatus
OBJECT-TYPE
The alarm status of the door sensor.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.7INTEGER {memNormal(1), memWarning(2), memCritical(3)}read-onlymandatory
memDoorSensorCommStatus
OBJECT-TYPE
The communication status of the door sensor.
1.3.6.1.4.1.318.1.1.10.4.7.8.1.8INTEGER {commOK(1), commLost(2)}read-onlymandatory
memSmokeSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.9not-accessiblemandatory
memSmokeSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.4.7.9.1not-accessiblemandatory
memSmokeSensorConfigSensorModuleIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.9.1.1INTEGERread-onlymandatory
memSmokeSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.9.1.2INTEGERread-onlymandatory
memSmokeSensorConfigSensorName
OBJECT-TYPE
The user defined name of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.4.7.9.1.3DisplayStringread-writemandatory
memSmokeSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the smoke sensor.
1.3.6.1.4.1.318.1.1.10.4.7.9.1.4DisplayStringread-writemandatory
memSmokeSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.9.1.5INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
memSmokeSensorConfigAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation on this input.
1.3.6.1.4.1.318.1.1.10.4.7.9.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
memVibrationSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.10not-accessiblemandatory
memVibrationSensorConfigEntry
OBJECT-TYPE
The sensor to configure.
1.3.6.1.4.1.318.1.1.10.4.7.10.1not-accessiblemandatory
memVibrationSensorModuleConfigIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.10.1.1INTEGERread-onlymandatory
memVibrationSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.10.1.2INTEGERread-onlymandatory
memVibrationSensorConfigSensorName
OBJECT-TYPE
The user defined name of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.4.7.10.1.3DisplayStringread-writemandatory
memVibrationSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the vibration sensor.
1.3.6.1.4.1.318.1.1.10.4.7.10.1.4DisplayStringread-writemandatory
memVibrationSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.10.1.5INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
memVibrationSensorConfigAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation on this input.
1.3.6.1.4.1.318.1.1.10.4.7.10.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
memFluidSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.11not-accessiblemandatory
memFluidSensorConfigEntry
OBJECT-TYPE
The sensor to configure.
1.3.6.1.4.1.318.1.1.10.4.7.11.1not-accessiblemandatory
memFluidSensorModuleConfigIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.11.1.1INTEGERread-onlymandatory
memFluidSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.11.1.2INTEGERread-onlymandatory
memFluidSensorConfigSensorName
OBJECT-TYPE
The user defined name of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.4.7.11.1.3DisplayStringread-writemandatory
memFluidSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the fluid sensor.
1.3.6.1.4.1.318.1.1.10.4.7.11.1.4DisplayStringread-writemandatory
memFluidSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.11.1.5INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
memFluidSensorConfigAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation on this input.
1.3.6.1.4.1.318.1.1.10.4.7.11.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
memDoorSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.4.7.12not-accessiblemandatory
memDoorSensorConfigEntry
OBJECT-TYPE
The sensors to configure.
1.3.6.1.4.1.318.1.1.10.4.7.12.1not-accessiblemandatory
memDoorSensorModuleConfigIndex
OBJECT-TYPE
The index to the sensor module entry.
1.3.6.1.4.1.318.1.1.10.4.7.12.1.1INTEGERread-onlymandatory
memDoorSensorConfigSensorIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.4.7.12.1.2INTEGERread-onlymandatory
memDoorSensorConfigSensorName
OBJECT-TYPE
The user defined name of the door sensor.
1.3.6.1.4.1.318.1.1.10.4.7.12.1.3DisplayStringread-writemandatory
memDoorSensorConfigSensorLocation
OBJECT-TYPE
The user defined location of the door sensor.
1.3.6.1.4.1.318.1.1.10.4.7.12.1.4DisplayStringread-writemandatory
memDoorSensorConfigSensorSeverity
OBJECT-TYPE
The severity of the alarm that will be triggered when the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3).
1.3.6.1.4.1.318.1.1.10.4.7.12.1.5INTEGER {critical(1), warning(2), informational(3)}read-writemandatory
memDoorSensorConfigAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation on this input.
1.3.6.1.4.1.318.1.1.10.4.7.12.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
envWireless
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.5
wirelessSensorStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.5.1
wirelessSensorStatusTable
OBJECT-TYPE
Allows for the access of individual sensors.
1.3.6.1.4.1.318.1.1.10.5.1.1not-accessiblemandatory
wirelessSensorStatusEntry
OBJECT-TYPE
A list of wireless sensor status table entries.
1.3.6.1.4.1.318.1.1.10.5.1.1.1not-accessiblemandatory
wirelessSensorStatusIndex
OBJECT-TYPE
The index to the sensor entry.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.1INTEGERread-onlymandatory
wirelessSensorStatusExtAddr
OBJECT-TYPE
The extended address is the combination of the unique 10 byte MAC address of the sensor concatenated with its short address.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.2DisplayStringread-onlymandatory
wirelessSensorStatusName
OBJECT-TYPE
The name of the wireless sensor.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.3DisplayStringread-onlymandatory
wirelessSensorStatusAlarmGeneration
OBJECT-TYPE
Indicates whether alarm generation is enabled or disabled for the sensor.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.4INTEGER {disabled(0), enabled(1)}read-onlymandatory
wirelessSensorStatusTemperature
OBJECT-TYPE
The current temperature are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.1.1.1.5INTEGERread-onlymandatory
wirelessSensorStatusHighTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.1.1.1.6INTEGERread-onlymandatory
wirelessSensorStatusLowTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.1.1.1.7INTEGERread-onlymandatory
wirelessSensorStatusHumidity
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.8INTEGERread-onlymandatory
wirelessSensorStatusHighHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.9INTEGERread-onlymandatory
wirelessSensorStatusLowHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.10INTEGERread-onlymandatory
wirelessSensorStatusCommStatus
OBJECT-TYPE
The communication status of the wireless sensor. inactive(0) indicates sensor is in the wireless network but not sending information. active(1) indicates wireless sensor is live and sending information.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.11INTEGER {inactive(0), active(1)}read-onlymandatory
wirelessSensorStatusMaxTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.1.1.1.12INTEGERread-onlymandatory
wirelessSensorStatusMinTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.1.1.1.13INTEGERread-onlymandatory
wirelessSensorStatusMaxHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.14INTEGERread-onlymandatory
wirelessSensorStatusMinHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.15INTEGERread-onlymandatory
wirelessSensorStatusBattery
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.16INTEGERread-onlymandatory
wirelessSensorStatusLowBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.17INTEGERread-onlymandatory
wirelessSensorStatusMinBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.18INTEGERread-onlymandatory
wirelessSensorStatusRssi
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.19INTEGERread-onlymandatory
wirelessSensorStatusLowRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.20INTEGERread-onlymandatory
wirelessSensorStatusMinRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.21INTEGERread-onlymandatory
wirelessSensorStatusLocation
OBJECT-TYPE
A user-defined string identifying the location of the wireless sensor.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.22DisplayStringread-onlymandatory
wirelessSensorStatusAlarmStatus
OBJECT-TYPE
The alarm status of the wireless sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Maximum humidity exceeded. 6 0x0020 High humidity exceeded. 7 0x0040 Low humidity exceeded. 8 0x0080 Minimum humidity exceeded. 9 0x0100 Low battery exceeded. 10 0x0200 Minimum battery exceeded. 11 0x0400 Low signal strength exceeded. 12 0x0800 Minimum signal strength exceeded. 13 0x1000 Sensor inactive.
1.3.6.1.4.1.318.1.1.10.5.1.1.1.23INTEGERread-onlymandatory
wirelessSensorPodStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.5.2
wirelessSensorPodStatusTable
OBJECT-TYPE
Allows for the access of individual pod sensors.
1.3.6.1.4.1.318.1.1.10.5.2.1not-accessiblemandatory
wirelessSensorPodStatusEntry
OBJECT-TYPE
The sensor pod to access.
1.3.6.1.4.1.318.1.1.10.5.2.1.1not-accessiblemandatory
wirelessSensorPodStatusIndex
OBJECT-TYPE
The index to the pod sensor entry.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.1INTEGERread-onlymandatory
wirelessSensorPodPortIndex
OBJECT-TYPE
The pod sensor port index.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.2INTEGERread-onlymandatory
wirelessSensorPodStatusExtAddr
OBJECT-TYPE
The extended address is the combination of the unique 10 byte MAC address of the sensor concatenated with its short address.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.3DisplayStringread-onlymandatory
wirelessSensorPodStatusName
OBJECT-TYPE
The name of the sensor pod.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.4DisplayStringread-onlymandatory
wirelessSensorPodStatusAlarmGeneration
OBJECT-TYPE
Status of whether alarm generation is enabled or disabled.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.5INTEGER {disabled(0), enabled(1)}read-onlymandatory
wirelessSensorPodStatusTemperature
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.2.1.1.6INTEGERread-onlymandatory
wirelessSensorPodStatusHighTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.2.1.1.7INTEGERread-onlymandatory
wirelessSensorPodStatusLowTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.2.1.1.8INTEGERread-onlymandatory
wirelessSensorPodStatusHumidity
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.9INTEGERread-onlymandatory
wirelessSensorPodStatusHighHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.10INTEGERread-onlymandatory
wirelessSensorPodStatusLowHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.11INTEGERread-onlymandatory
wirelessSensorPodStatusCommStatus
OBJECT-TYPE
The communication status of the wireless sensor. inactive(0) indicates pod sensor is in the wireless network but not sending information. active(1) indicates wireless sensor is live and sending information.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.12INTEGER {inactive(0), active(1)}read-onlymandatory
wirelessSensorPodStatusMaxTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.2.1.1.13INTEGERread-onlymandatory
wirelessSensorPodStatusMinTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.2.1.1.14INTEGERread-onlymandatory
wirelessSensorPodStatusMaxHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.15INTEGERread-onlymandatory
wirelessSensorPodStatusMinHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.16INTEGERread-onlymandatory
wirelessSensorPodStatusDryContactState
OBJECT-TYPE
State of the dry contact. If the dry contact is closed, the drycontactClosed (1) value will be returned. If the dry contact state is open, the drycontactOpen (0) value will be returned.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.17INTEGER {drycontactOpen(0), drycontactClosed(1)}read-onlymandatory
wirelessSensorPodStatusDryContactNormalState
OBJECT-TYPE
The normal state of the dry contact. If the normal state is closed, the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpen (0) value will be returned.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.18INTEGER {normallyOpen(0), normallyClosed(1)}read-onlymandatory
wirelessSensorPodStatusBattery
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.19INTEGERread-onlymandatory
wirelessSensorPodStatusLowBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.20INTEGERread-onlymandatory
wirelessSensorPodStatusMinBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.21INTEGERread-onlymandatory
wirelessSensorPodStatusRssi
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.22INTEGERread-onlymandatory
wirelessSensorPodStatusLowRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.23INTEGERread-onlymandatory
wirelessSensorPodStatusMinRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.24INTEGERread-onlymandatory
wirelessSensorPodStatusLocation
OBJECT-TYPE
The location of the wireless sensor pod.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.25DisplayStringread-onlymandatory
wirelessSensorPodStatusAlarmStatus
OBJECT-TYPE
The alarm status of the wireless pod sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Maximum humidity exceeded. 6 0x0020 High humidity exceeded. 7 0x0040 Low humidity exceeded. 8 0x0080 Minimum humidity exceeded. 9 0x0100 Low battery exceeded. 10 0x0200 Minimum battery exceeded. 11 0x0400 Low signal strength exceeded. 12 0x0800 Minimum signal strength exceeded. 13 0x1000 Sensor inactive. 14 0x2000 Dry contact in Critical state. 15 0x4000 Dry contact in warning state.
1.3.6.1.4.1.318.1.1.10.5.2.1.1.26INTEGERread-onlymandatory
wirelessSensorConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.5.3
wirelessSensorConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.5.3.1not-accessiblemandatory
wirelessSensorConfigEntry
OBJECT-TYPE
The sensor to configure.
1.3.6.1.4.1.318.1.1.10.5.3.1.1not-accessiblemandatory
wirelessSensorConfigIndex
OBJECT-TYPE
The index to the entry.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.1INTEGERread-onlymandatory
wirelessSensorConfigName
OBJECT-TYPE
The user-defined wireless sensor ID string.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.2DisplayStringread-writemandatory
wirelessSensorConfigAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation for this sensor.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.3INTEGER {disabled(0), enabled(1)}read-writemandatory
wirelessSensorConfigHighTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.3.1.1.4INTEGERread-writemandatory
wirelessSensorConfigLowTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.3.1.1.5INTEGERread-writemandatory
wirelessSensorConfigHighHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.6INTEGERread-writemandatory
wirelessSensorConfigLowHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.7INTEGERread-writemandatory
wirelessSensorConfigMaxTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.3.1.1.8INTEGERread-writemandatory
wirelessSensorConfigMinTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.3.1.1.9INTEGERread-writemandatory
wirelessSensorConfigMaxHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.10INTEGERread-writemandatory
wirelessSensorConfigMinHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.11INTEGERread-writemandatory
wirelessSensorConfigLowBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.12INTEGERread-writemandatory
wirelessSensorConfigMinBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.13INTEGERread-writemandatory
wirelessSensorConfigLowRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.14INTEGERread-writemandatory
wirelessSensorConfigMinRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.15INTEGERread-writemandatory
wirelessSensorConfigLocation
OBJECT-TYPE
A user-defined string identifying the location of the wireless sensor. Maximum text input is 20 characters.
1.3.6.1.4.1.318.1.1.10.5.3.1.1.16DisplayStringread-writemandatory
wirelessSensorPodConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.10.5.4
wirelessSensorPodConfigTable
OBJECT-TYPE
Allows for the configuration of individual sensors.
1.3.6.1.4.1.318.1.1.10.5.4.1not-accessiblemandatory
wirelessSensorPodConfigEntry
OBJECT-TYPE
The sensor to configure.
1.3.6.1.4.1.318.1.1.10.5.4.1.1not-accessiblemandatory
wirelessSensorPodConfigIndex
OBJECT-TYPE
The index to the entry.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.1INTEGERread-onlymandatory
wirelessSensorPodConfigPortIndex
OBJECT-TYPE
The sensor pod port index.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.2INTEGERread-onlymandatory
wirelessSensorPodConfigName
OBJECT-TYPE
The user defined name of the sensor pod.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.3DisplayStringread-writemandatory
wirelessSensorPodConfigAlarmGeneration
OBJECT-TYPE
Enable or disable alarm generation for this sensor.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.4INTEGER {disabled(0), enabled(1)}read-writemandatory
wirelessSensorPodConfigDryContactNormalState
OBJECT-TYPE
The normal state of the dry contact. If the normal state is closed, the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpen (0) value will be returned. Setting this variable will change the normal state of the dry contact.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.5INTEGER {normallyOpen(0), normallyClosed(1)}read-writemandatory
wirelessSensorPodConfigHighTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.4.1.1.6INTEGERread-writemandatory
wirelessSensorPodConfigLowTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.4.1.1.7INTEGERread-writemandatory
wirelessSensorPodConfigHighHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.8INTEGERread-writemandatory
wirelessSensorPodConfigLowHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.9INTEGERread-writemandatory
wirelessSensorPodConfigMaxTempThresh
OBJECT-TYPE
Values are displayed in tenths of degrees in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.4.1.1.10INTEGERread-writemandatory
wirelessSensorPodConfigMinTempThresh
OBJECT-TYPE
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.10.5.4.1.1.11INTEGERread-writemandatory
wirelessSensorPodConfigMaxHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.12INTEGERread-writemandatory
wirelessSensorPodConfigMinHumidityThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.13INTEGERread-writemandatory
wirelessSensorPodConfigLowBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.14INTEGERread-writemandatory
wirelessSensorPodConfigMinBatteryThresh
OBJECT-TYPE
Values are displayed in tenths of Volts DC.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.15INTEGERread-writemandatory
wirelessSensorPodConfigLowRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.16INTEGERread-writemandatory
wirelessSensorPodConfigMinRssiThresh
OBJECT-TYPE
Values are represented in whole number percentage.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.17INTEGERread-writemandatory
wirelessSensorPodConfigLocation
OBJECT-TYPE
A user-defined string identifying the location of the wireless pod sensor. Maximum text input is 20 characters.
1.3.6.1.4.1.318.1.1.10.5.4.1.1.18DisplayStringread-writemandatory
netlock
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.11
nlIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.11.1
nlStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.11.2
rPDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12
rPDUIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.1
rPDUIdentName
OBJECT-TYPE
The name of the Rack PDU. The maximum string size is device dependent.
1.3.6.1.4.1.318.1.1.12.1.1DisplayStringread-writemandatory
rPDUIdentHardwareRev
OBJECT-TYPE
The hardware revision of the Rack PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.12.1.2DisplayStringread-onlymandatory
rPDUIdentFirmwareRev
OBJECT-TYPE
An 8-byte ID string identifying the Rack PDU firmware revision. This value is set at the factory.
1.3.6.1.4.1.318.1.1.12.1.3DisplayStringread-onlymandatory
rPDUIdentDateOfManufacture
OBJECT-TYPE
The date when the Rack PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. The year 2000 will be represented by 00.
1.3.6.1.4.1.318.1.1.12.1.4DisplayStringread-onlymandatory
rPDUIdentModelNumber
OBJECT-TYPE
A 10-character string identifying the model number of the Rack PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.12.1.5DisplayStringread-onlymandatory
rPDUIdentSerialNumber
OBJECT-TYPE
A 12-character string identifying the serial number of the Rack PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.12.1.6DisplayStringread-onlymandatory
rPDUIdentDeviceRating
OBJECT-TYPE
Getting this OID will return the electrical rating of the device in Amps.
1.3.6.1.4.1.318.1.1.12.1.7INTEGERread-onlymandatory
rPDUIdentDeviceNumOutlets
OBJECT-TYPE
Getting this OID will return the number of outlets contained in the device.
1.3.6.1.4.1.318.1.1.12.1.8INTEGERread-onlymandatory
rPDUIdentDeviceNumPhases
OBJECT-TYPE
Getting this OID will return the number of phases supported by the device.
1.3.6.1.4.1.318.1.1.12.1.9INTEGERread-onlymandatory
rPDUIdentDeviceNumBreakers
OBJECT-TYPE
Getting this OID will return the number of circuit breakers supported by the device. This is the same as the number of banks of outlets. 0 will be returned if the unit has no phase breakers.
1.3.6.1.4.1.318.1.1.12.1.10INTEGERread-onlymandatory
rPDUIdentDeviceBreakerRating
OBJECT-TYPE
Getting this OID will return rating of the circuit breakers on the device in Amps if it has any.
1.3.6.1.4.1.318.1.1.12.1.11INTEGERread-onlymandatory
rPDUIdentDeviceOrientation
OBJECT-TYPE
Getting this OID will return the intended physical orientation of the device. OrientHorizonatal(1) indicates Horizontal. OrientVertical(2) indicates Vertical.
1.3.6.1.4.1.318.1.1.12.1.12INTEGER {orientHorizontal(1), orientVertical(2)}read-onlymandatory
rPDUIdentDeviceOutletLayout
OBJECT-TYPE
Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. For AP7xxx SKU's Group 1:3-1. Group 2:2-3, Group 3:1-2. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available.
1.3.6.1.4.1.318.1.1.12.1.13INTEGER {seqPhaseToNeutral(1), seqPhaseToPhase(2), seqPhToNeu21PhToPh(3), seqPhToPhGrouped(4), seqPhToNGrouped(5), seqPToN1516PToPGrouped(6), seqPhToPh2xGrouped(7), seqPhToN2xGrouped(8), seqNotApplicable(9)}read-onlymandatory
rPDUIdentDeviceDisplayOrientation
OBJECT-TYPE
Getting this OID will return the intended physical orientation of the Seven-Segment Display. Normal(1) indicates Normal. Reverse(2)indicates Upside-Down.
1.3.6.1.4.1.318.1.1.12.1.14INTEGER {displayNormal(1), displayReverse(2)}read-writemandatory
rPDUIdentDeviceLinetoLineVoltage
OBJECT-TYPE
Getting/Setting this OID will return/set the Line to Line Voltage. This OID defaults to the nominal input line voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID does not apply to AP86XX, AP88XX, or AP89XX SKUs. The valid range is between 0V to 440V
1.3.6.1.4.1.318.1.1.12.1.15INTEGERread-writemandatory
rPDUIdentDevicePowerWatts
OBJECT-TYPE
Getting this OID will return the Power in Watts.
1.3.6.1.4.1.318.1.1.12.1.16INTEGERread-onlymandatory
rPDUIdentDevicePowerFactor
OBJECT-TYPE
Getting/setting this OID will return/set the Power Factor in thousandths (1000 is power factor of 1). For AP8XXX SKUs, this OID is read-only Valid range is from 0 to 1000.
1.3.6.1.4.1.318.1.1.12.1.17INTEGERread-writemandatory
rPDUIdentDevicePowerVA
OBJECT-TYPE
Getting this OID will return the Power in VA.
1.3.6.1.4.1.318.1.1.12.1.18INTEGERread-onlymandatory
rPDUIdentDeviceLinetoNeutralVoltage
OBJECT-TYPE
Getting/Setting this OID will return/set the Line to Neutral Voltage. This OID defaults to the nominal line to neutral voltage in volts AC. This setting is used to calculate total power and must be configured for best accuracy. This OID applies only to AP7823. For all other models, the OID is fixed at 0. The valid range is between 0V to 440V.
1.3.6.1.4.1.318.1.1.12.1.19INTEGERread-writemandatory
rPDULoad
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.2
rPDULoadDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.2.1
rPDULoadDevMaxPhaseLoad
OBJECT-TYPE
Getting this OID will return the maximum rated power that each phase of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the unit is banked.
1.3.6.1.4.1.318.1.1.12.2.1.1INTEGERread-onlymandatory
rPDULoadDevNumPhases
OBJECT-TYPE
The number of phases available with this Rack PDU.
1.3.6.1.4.1.318.1.1.12.2.1.2INTEGERread-onlymandatory
rPDULoadDevMaxBankLoad
OBJECT-TYPE
Getting this OID will return the maximum rated power that a bank of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the device does not have any banks.
1.3.6.1.4.1.318.1.1.12.2.1.3INTEGERread-onlymandatory
rPDULoadDevNumBanks
OBJECT-TYPE
The number of banks of outlets available with this Rack PDU. A bank of outlets has a unique circuit breaker for a subset of the total number of outlets on the rPDU. 0 will be returned if the unit has no banks.
1.3.6.1.4.1.318.1.1.12.2.1.4INTEGERread-onlymandatory
rPDULoadDevBankTableSize
OBJECT-TYPE
The size of the Bank Table.
1.3.6.1.4.1.318.1.1.12.2.1.5INTEGERread-onlymandatory
rPDULoadDevBankTable
OBJECT-TYPE
Allows for getting the Bank Max Load in the Rack PDU.
1.3.6.1.4.1.318.1.1.12.2.1.6not-accessiblemandatory
rPDULoadDevBankEntry
OBJECT-TYPE
The Rack PDU Banks Access.
1.3.6.1.4.1.318.1.1.12.2.1.6.1not-accessiblemandatory
rPDULoadDevBankIndex
OBJECT-TYPE
The index to the Rack PDU bank entry.
1.3.6.1.4.1.318.1.1.12.2.1.6.1.1INTEGERread-onlymandatory
rPDULoadDevBankNumber
OBJECT-TYPE
Getting this OID will return the bank number.
1.3.6.1.4.1.318.1.1.12.2.1.6.1.2INTEGERread-onlymandatory
rPDULoadDevBankMaxLoad
OBJECT-TYPE
Getting this OID will return the maximum rated power that each bank of the Rack PDU can provide. It is represented in Amps.
1.3.6.1.4.1.318.1.1.12.2.1.6.1.3INTEGERread-onlymandatory
rPDULoadDevMaxOutletTableSize
OBJECT-TYPE
The size of the Outlet Table.
1.3.6.1.4.1.318.1.1.12.2.1.7INTEGERread-onlymandatory
rPDULoadDevMaxOutletTable
OBJECT-TYPE
Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU.
1.3.6.1.4.1.318.1.1.12.2.1.8not-accessiblemandatory
rPDULoadDevMaxOutletEntry
OBJECT-TYPE
This gives access to Max Outlet Load of an Outlet Monitored Rack PDU
1.3.6.1.4.1.318.1.1.12.2.1.8.1not-accessiblemandatory
rPDULoadDevOutletIndex
OBJECT-TYPE
The index to the Outlet Monitored Rack PDU Max Outlet Load entry.
1.3.6.1.4.1.318.1.1.12.2.1.8.1.1INTEGERread-onlymandatory
rPDULoadDevOutletNumber
OBJECT-TYPE
Getting this OID will return the Outlet number.
1.3.6.1.4.1.318.1.1.12.2.1.8.1.2INTEGERread-onlymandatory
rPDULoadDevMaxOutletLoad
OBJECT-TYPE
Getting this OID will return the maximum rated power that each Outlet of an Outlet Monitored Rack PDU can provide. It is represented in Amps.
1.3.6.1.4.1.318.1.1.12.2.1.8.1.3INTEGERread-onlymandatory
rPDULoadPhaseConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.2.2
rPDULoadPhaseConfigTable
OBJECT-TYPE
Allows for configuration of each Rack PDU phase. The number of entries is contained in the rPDULoadDevNumPhases OID.
1.3.6.1.4.1.318.1.1.12.2.2.1not-accessiblemandatory
rPDULoadPhaseConfigEntry
OBJECT-TYPE
The Rack PDU phase to configure.
1.3.6.1.4.1.318.1.1.12.2.2.1.1not-accessiblemandatory
rPDULoadPhaseConfigIndex
OBJECT-TYPE
The index to the Rack PDU phase entry.
1.3.6.1.4.1.318.1.1.12.2.2.1.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
rPDULoadPhaseConfigLowLoadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDULoadPhaseConfigNearOverloadThreshold OID.
1.3.6.1.4.1.318.1.1.12.2.2.1.1.2INTEGERread-writemandatory
rPDULoadPhaseConfigNearOverloadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDULoadPhaseConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadPhaseConfigOverloadThreshold OID.
1.3.6.1.4.1.318.1.1.12.2.2.1.1.3INTEGERread-writemandatory
rPDULoadPhaseConfigOverloadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDULoadPhaseConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxPhaseLoad OID.
1.3.6.1.4.1.318.1.1.12.2.2.1.1.4INTEGERread-writemandatory
rPDULoadPhaseConfigAlarm
OBJECT-TYPE
Getting this OID will return the current Phase Alarm.
1.3.6.1.4.1.318.1.1.12.2.2.1.1.5INTEGER {noLoadAlarm(1), underCurrentAlarm(2), nearOverCurrentAlarm(3), overCurrentAlarm(4)}read-onlymandatory
rPDULoadStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.2.3
rPDULoadStatusTable
OBJECT-TYPE
Allows for getting of status of each Rack PDU phase/bank. The number of entries is calculated by adding the number of phases (rPDULoadDevNumPhases OID) and the number of banks of outlets (rPDULoadDevNumBanks) Number of entries = #phases + #banks. NOTE: If a device has phase and bank information, all phase information shall precede the bank information. If a device has total information, it shall precede both the bank and the phase information.
1.3.6.1.4.1.318.1.1.12.2.3.1not-accessiblemandatory
rPDULoadStatusEntry
OBJECT-TYPE
The Rack PDU phase/bank to gather status from.
1.3.6.1.4.1.318.1.1.12.2.3.1.1not-accessiblemandatory
rPDULoadStatusIndex
OBJECT-TYPE
The index to the Rack PDU phase/bank entry. All phase information will precede any bank information
1.3.6.1.4.1.318.1.1.12.2.3.1.1.1INTEGERread-onlymandatory
rPDULoadStatusLoad
OBJECT-TYPE
Getting this OID will return the phase/bank load measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.12.2.3.1.1.2Gaugeread-onlymandatory
rPDULoadStatusLoadState
OBJECT-TYPE
Getting this OID will return the phase/bank load state. phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoadThreshold and rPDULoadConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the phase/bank load has dropped below the rPDULoadConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
1.3.6.1.4.1.318.1.1.12.2.3.1.1.3INTEGER {phaseLoadNormal(1), phaseLoadLow(2), phaseLoadNearOverload(3), phaseLoadOverload(4)}read-onlymandatory
rPDULoadStatusPhaseNumber
OBJECT-TYPE
The phase number to which this record refers.
1.3.6.1.4.1.318.1.1.12.2.3.1.1.4INTEGERread-onlymandatory
rPDULoadStatusBankNumber
OBJECT-TYPE
The bank number to which this record refers. A value of 0 will be returned if any bank is not present or if it is phase related.
1.3.6.1.4.1.318.1.1.12.2.3.1.1.5INTEGERread-onlymandatory
rPDULoadBankConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.2.4
rPDULoadBankConfigTable
OBJECT-TYPE
Allows for configuration of each Rack PDU bank. The number of entries is contained in the rPDULoadDevNumBanks OID.
1.3.6.1.4.1.318.1.1.12.2.4.1not-accessiblemandatory
rPDULoadBankConfigEntry
OBJECT-TYPE
The Rack PDU bank to configure.
1.3.6.1.4.1.318.1.1.12.2.4.1.1not-accessiblemandatory
rPDULoadBankConfigIndex
OBJECT-TYPE
The index to the Rack PDU bank entry.
1.3.6.1.4.1.318.1.1.12.2.4.1.1.1INTEGERread-onlymandatory
rPDULoadBankConfigLowLoadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDULoadBankConfigNearOverloadThreshold OID.
1.3.6.1.4.1.318.1.1.12.2.4.1.1.2INTEGERread-writemandatory
rPDULoadBankConfigNearOverloadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDULoadBankConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadBankConfigOverloadThreshold OID.
1.3.6.1.4.1.318.1.1.12.2.4.1.1.3INTEGERread-writemandatory
rPDULoadBankConfigOverloadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDULoadBankConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxBankLoad OID.
1.3.6.1.4.1.318.1.1.12.2.4.1.1.4INTEGERread-writemandatory
rPDULoadBankConfigAlarm
OBJECT-TYPE
Getting this OID will return the current Bank Alarm.
1.3.6.1.4.1.318.1.1.12.2.4.1.1.5INTEGER {noLoadAlarm(1), underCurrentAlarm(2), nearOverCurrentAlarm(3), overCurrentAlarm(4)}read-onlymandatory
rPDUOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3
rPDUOutletDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3.1
rPDUOutletDevCommand
OBJECT-TYPE
Setting this OID to immediateAllOn (2) will turn all outlets on immediately. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will reboot all outlets immediately. Setting this OID to delayedAllOn (5) will turn all outlets on as defined by each outlet's rPDUOutletConfigPowerOnTime OID value. Setting this OID to delayedAllOff (6) will turn all outlets off as defined by each outlet's rPDUOutletConfigPowerOffTime OID value. Setting this OID to delayedAllReboot (7) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest rPDUOutletConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be canceled. Getting this OID will return the noCommandAll (1) value.
1.3.6.1.4.1.318.1.1.12.3.1.1INTEGER {noCommandAll(1), immediateAllOn(2), immediateAllOff(3), immediateAllReboot(4), delayedAllOn(5), delayedAllOff(6), delayedAllReboot(7), cancelAllPendingCommands(8)}read-writemandatory
rPDUOutletDevColdstartDelay
OBJECT-TYPE
The amount of delay, in seconds, between when power is provided to the Switched Rack PDU and when the Switched Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes).
1.3.6.1.4.1.318.1.1.12.3.1.2INTEGERread-writemandatory
rPDUOutletDevNumCntrlOutlets
OBJECT-TYPE
The number of controlled outlets on this Switched Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.1.3INTEGERread-onlymandatory
rPDUOutletDevNumTotalOutlets
OBJECT-TYPE
The total number of outlets on this Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.1.4INTEGERread-onlymandatory
rPDUOutletDevMonitoredOutlets
OBJECT-TYPE
The total number of monitored outlets on this Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.1.5INTEGERread-onlymandatory
rPDUOutletPhase
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3.2
rPDUOutletPhaseTable
OBJECT-TYPE
Allows for management of outlets on a per phase basis.
1.3.6.1.4.1.318.1.1.12.3.2.1not-accessiblemandatory
rPDUOutletPhaseEntry
OBJECT-TYPE
The phase to manage.
1.3.6.1.4.1.318.1.1.12.3.2.1.1not-accessiblemandatory
rPDUOutletPhaseIndex
OBJECT-TYPE
The index to the Switched Rack PDU phase entry.
1.3.6.1.4.1.318.1.1.12.3.2.1.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
rPDUOutletPhaseOverloadRestriction
OBJECT-TYPE
This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigOverloadThreshold OID is exceeded.
1.3.6.1.4.1.318.1.1.12.3.2.1.1.2INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3)}read-writemandatory
rPDUOutletControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3.3
rPDUOutletControlTable
OBJECT-TYPE
Allows for control of the individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID.
1.3.6.1.4.1.318.1.1.12.3.3.1not-accessiblemandatory
rPDUOutletControlEntry
OBJECT-TYPE
The outlet to control.
1.3.6.1.4.1.318.1.1.12.3.3.1.1not-accessiblemandatory
rPDUOutletControlIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.12.3.3.1.1.1INTEGERread-onlymandatory
rPDUOutletControlOutletName
OBJECT-TYPE
The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.12.3.3.1.1.2DisplayStringread-onlymandatory
rPDUOutletControlOutletPhase
OBJECT-TYPE
The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
1.3.6.1.4.1.318.1.1.12.3.3.1.1.3INTEGER {phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlymandatory
rPDUOutletControlOutletCommand
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will immediately reboot the outlet. Setting this variable to delayedOn (4) will turn the outlet on after the rPDUOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (5) will turn the outlet off after the rPDUOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched Rack PDU to perform a delayedOff command, wait the rPDUOutletConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (7) will cause any pending command to this outlet to be canceled.
1.3.6.1.4.1.318.1.1.12.3.3.1.1.4INTEGER {immediateOn(1), immediateOff(2), immediateReboot(3), delayedOn(4), delayedOff(5), delayedReboot(6), cancelPendingCommand(7)}read-writemandatory
rPDUOutletControlOutletBank
OBJECT-TYPE
The bank associated with this outlet.
1.3.6.1.4.1.318.1.1.12.3.3.1.1.5INTEGERread-onlymandatory
rPDUOutletConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3.4
rPDUOutletConfigTable
OBJECT-TYPE
Allows for configuration of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID.
1.3.6.1.4.1.318.1.1.12.3.4.1not-accessiblemandatory
rPDUOutletConfigEntry
OBJECT-TYPE
The outlet to configure.
1.3.6.1.4.1.318.1.1.12.3.4.1.1not-accessiblemandatory
rPDUOutletConfigIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.12.3.4.1.1.1INTEGERread-onlymandatory
rPDUOutletConfigOutletName
OBJECT-TYPE
The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size.
1.3.6.1.4.1.318.1.1.12.3.4.1.1.2DisplayStringread-writemandatory
rPDUOutletConfigOutletPhase
OBJECT-TYPE
The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
1.3.6.1.4.1.318.1.1.12.3.4.1.1.3INTEGER {phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlymandatory
rPDUOutletConfigPowerOnTime
OBJECT-TYPE
The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 - power on immediately. 1 to 7200 - power on up to 7200 seconds after being commanded.
1.3.6.1.4.1.318.1.1.12.3.4.1.1.4INTEGERread-writemandatory
rPDUOutletConfigPowerOffTime
OBJECT-TYPE
The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - power off immediately. 1 to 7200 - power off up to 7200 seconds after being commanded.
1.3.6.1.4.1.318.1.1.12.3.4.1.1.5INTEGERread-writemandatory
rPDUOutletConfigRebootDuration
OBJECT-TYPE
During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute).
1.3.6.1.4.1.318.1.1.12.3.4.1.1.6INTEGERread-writemandatory
rPDUOutletConfigOutletBank
OBJECT-TYPE
The bank associated with this outlet.
1.3.6.1.4.1.318.1.1.12.3.4.1.1.7INTEGERread-onlymandatory
rPDUOutletConfigMonitoredTableSize
OBJECT-TYPE
The size of the Outlet Config Monitored Table
1.3.6.1.4.1.318.1.1.12.3.4.2INTEGERread-onlymandatory
rPDUOutletConfigMonitoredTable
OBJECT-TYPE
Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.4.3not-accessiblemandatory
rPDUOutletConfigMonitoredEntry
OBJECT-TYPE
This gives access to Monitored Outlet entries
1.3.6.1.4.1.318.1.1.12.3.4.3.1not-accessiblemandatory
rPDUOutletConfigMonitoredIndex
OBJECT-TYPE
The index to the RACK PDU Phase entry.
1.3.6.1.4.1.318.1.1.12.3.4.3.1.1INTEGERread-onlymandatory
rPDUOutletConfigMonitoredName
OBJECT-TYPE
The name of the Monitored Outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size.
1.3.6.1.4.1.318.1.1.12.3.4.3.1.2DisplayStringread-writemandatory
rPDUOutletConfigMonitoredNumber
OBJECT-TYPE
The outlet number of an Outlet Monitored RACK PDU.
1.3.6.1.4.1.318.1.1.12.3.4.3.1.3INTEGERread-onlymandatory
rPDUOutletConfigMonitoredLowLoadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.4.3.1.4INTEGERread-writemandatory
rPDUOutletConfigMonitoredNearOverloadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the rPDUOutletConfigMonitoredLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDUOutletConfigMonitoredOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.4.3.1.5INTEGERread-writemandatory
rPDUOutletConfigMonitoredOverloadThreshold
OBJECT-TYPE
A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the rPDUOutletConfigMonitoredNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the rPDULoadDevMaxOutletLoad OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU.
1.3.6.1.4.1.318.1.1.12.3.4.3.1.6INTEGERread-writemandatory
rPDUOutletStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3.5
rPDUOutletStatusTable
OBJECT-TYPE
Allows for getting of status of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID or rPDUOutletDevMonitoredOutlets OID.
1.3.6.1.4.1.318.1.1.12.3.5.1not-accessiblemandatory
rPDUOutletStatusEntry
OBJECT-TYPE
The outlet to gather status from.
1.3.6.1.4.1.318.1.1.12.3.5.1.1not-accessiblemandatory
rPDUOutletStatusIndex
OBJECT-TYPE
The index to the outlet entry.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.1INTEGERread-onlymandatory
rPDUOutletStatusOutletName
OBJECT-TYPE
The name of the outlet. The maximum string size is device dependent. This OID is provided for informational purposes only.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.2DisplayStringread-onlymandatory
rPDUOutletStatusOutletPhase
OBJECT-TYPE
The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.3INTEGER {phase1(1), phase2(2), phase3(3), phase1-2(4), phase2-3(5), phase3-1(6)}read-onlymandatory
rPDUOutletStatusOutletState
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusOff (2) value will be returned.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.4INTEGER {outletStatusOn(1), outletStatusOff(2)}read-onlymandatory
rPDUOutletStatusCommandPending
OBJECT-TYPE
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.5INTEGER {outletStatusCommandPending(1), outletStatusNoCommandPending(2)}read-onlymandatory
rPDUOutletStatusOutletBank
OBJECT-TYPE
The bank associated with this outlet.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.6INTEGERread-onlymandatory
rPDUOutletStatusLoad
OBJECT-TYPE
Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in tenths of Amps. For other models this OID is not supported.
1.3.6.1.4.1.318.1.1.12.3.5.1.1.7Gaugeread-onlymandatory
rPDUOutletBank
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.3.6
rPDUOutletBankTable
OBJECT-TYPE
Allows for management of outlets on a per bank basis.
1.3.6.1.4.1.318.1.1.12.3.6.1not-accessiblemandatory
rPDUOutletBankEntry
OBJECT-TYPE
The bank to manage.
1.3.6.1.4.1.318.1.1.12.3.6.1.1not-accessiblemandatory
rPDUOutletBankIndex
OBJECT-TYPE
The index to the Switched Rack PDU bank entry.
1.3.6.1.4.1.318.1.1.12.3.6.1.1.1INTEGERread-onlymandatory
rPDUOutletBankOverloadRestriction
OBJECT-TYPE
This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the rPDULoadBankConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the rPDULoadBankConfigOverloadThreshold OID is exceeded.
1.3.6.1.4.1.318.1.1.12.3.6.1.1.2INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3)}read-writemandatory
rPDUPowerSupply
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.4
rPDUPowerSupplyDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.4.1
rPDUPowerSupply1Status
OBJECT-TYPE
Getting this OID will return powerSupply1Ok(1) if power supply 1 is functioning normally. If not functioning normally, this OID will return powerSupply1Failed(2).
1.3.6.1.4.1.318.1.1.12.4.1.1INTEGER {powerSupplyOneOk(1), powerSupplyOneFailed(2)}read-onlymandatory
rPDUPowerSupply2Status
OBJECT-TYPE
Getting this OID will return powerSupply2Ok(1) if power supply 2 is functioning normally. If not functioning normally, this OID will return powerSupply2Failed(2). Metered Rack PDUs do not have a redundant powersupply.
1.3.6.1.4.1.318.1.1.12.4.1.2INTEGER {powerSupplyTwoOk(1), powerSupplyTwoFailed(2), powerSupplyTwoNotPresent(3)}read-onlymandatory
rPDUPowerSupplyAlarm
OBJECT-TYPE
Getting this OID will return powerSupply Alarm
1.3.6.1.4.1.318.1.1.12.4.1.3INTEGER {allAvailablePowerSuppliesOK(1), powerSupplyOneFailed(2), powerSupplyTwoFailed(3), powerSupplyOneandTwoFailed(4)}read-onlymandatory
rPDUStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.12.5
rPDUStatusBankTableSize
OBJECT-TYPE
The size of the Status Bank Table
1.3.6.1.4.1.318.1.1.12.5.1INTEGERread-onlymandatory
rPDUStatusBankTable
OBJECT-TYPE
Allows for getting of status of each Rack PDU Bank
1.3.6.1.4.1.318.1.1.12.5.2not-accessiblemandatory
rPDUStatusBankEntry
OBJECT-TYPE
This gives access to Bank entries
1.3.6.1.4.1.318.1.1.12.5.2.1not-accessiblemandatory
rPDUStatusBankIndex
OBJECT-TYPE
The index to the RACK PDU Bank entry.
1.3.6.1.4.1.318.1.1.12.5.2.1.1INTEGERread-onlymandatory
rPDUStatusBankNumber
OBJECT-TYPE
Getting this OID will return the bank number.
1.3.6.1.4.1.318.1.1.12.5.2.1.2INTEGERread-onlymandatory
rPDUStatusBankState
OBJECT-TYPE
Getting this OID will return the bank load state. bankLoadNormal(1) indicates that the bank is operating properly within the rPDULoadBankConfigLowLoadThreshold and rPDULoadBankConfigNearOverloadThreshold OID values. bankLoadLow(2) indicates that the bank load has dropped below the rPDULoadBankConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadNearOverload(3) indicates that the bank load is greater than or equal to the rPDULoadBankConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadOverload(4) indicates that the bank load is greater than or equal to the rPDULoadBankConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
1.3.6.1.4.1.318.1.1.12.5.2.1.3INTEGER {bankLoadNormal(1), bankLoadLow(2), bankLoadNearOverload(3), bankLoadOverload(4)}read-onlymandatory
rPDUStatusPhaseTableSize
OBJECT-TYPE
The size of the Status Phase Table
1.3.6.1.4.1.318.1.1.12.5.3INTEGERread-onlymandatory
rPDUStatusPhaseTable
OBJECT-TYPE
Allows for getting of status of each Rack PDU Phase
1.3.6.1.4.1.318.1.1.12.5.4not-accessiblemandatory
rPDUStatusPhaseEntry
OBJECT-TYPE
This gives access to Phase entries
1.3.6.1.4.1.318.1.1.12.5.4.1not-accessiblemandatory
rPDUStatusPhaseIndex
OBJECT-TYPE
The index to the RACK PDU Phase entry.
1.3.6.1.4.1.318.1.1.12.5.4.1.1INTEGERread-onlymandatory
rPDUStatusPhaseNumber
OBJECT-TYPE
Getting this OID will return the phase number.
1.3.6.1.4.1.318.1.1.12.5.4.1.2INTEGERread-onlymandatory
rPDUStatusPhaseState
OBJECT-TYPE
Getting this OID will return the Phase load state. phaseLoadNormal(1) indicates that the Phase is operating properly within the rPDULoadPhaseConfigLowLoadThreshold and rPDULoadPhaseConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the Phase load has dropped below the rPDULoadPhaseConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the Phase load is greater than or equal to the rPDULoadPhaseConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the Phase load is greater than or equal to the rPDULoadPhaseConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
1.3.6.1.4.1.318.1.1.12.5.4.1.3INTEGER {phaseLoadNormal(1), phaseLoadLow(2), phaseLoadNearOverload(3), phaseLoadOverload(4)}read-onlymandatory
rPDUStatusOutletTableSize
OBJECT-TYPE
The size of the Status Outlet Table
1.3.6.1.4.1.318.1.1.12.5.5INTEGERread-onlymandatory
rPDUStatusOutletTable
OBJECT-TYPE
Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
1.3.6.1.4.1.318.1.1.12.5.6not-accessiblemandatory
rPDUStatusOutletEntry
OBJECT-TYPE
This gives access to Outlet entries
1.3.6.1.4.1.318.1.1.12.5.6.1not-accessiblemandatory
rPDUStatusOutletIndex
OBJECT-TYPE
The index to the RACK PDU Outlet entry.
1.3.6.1.4.1.318.1.1.12.5.6.1.1INTEGERread-onlymandatory
rPDUStatusOutletNumber
OBJECT-TYPE
Getting this OID will return the Outlet number.
1.3.6.1.4.1.318.1.1.12.5.6.1.2INTEGERread-onlymandatory
rPDUStatusOutletState
OBJECT-TYPE
Getting this OID will return the Outlet load state. outletLoadNormal(1) indicates that the Outlet is operating properly within the rPDUOutletConfigMonitoredLowLoadThreshold and rPDUOutletConfigMonitoredNearOverloadThreshold OID values. outletLoadLow(2) indicates that the Outlet load has dropped below the rPDUOutletConfigMonitoredLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadNearOverload(3) indicates that the Outlet load is greater than or equal to the rPDUOutletConfigMonitoredNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadOverload(4) indicates that the Outlet load is greater than or equal to the rPDUOutletConfigMonitoredOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
1.3.6.1.4.1.318.1.1.12.5.6.1.3INTEGER {outletLoadNormal(1), outletLoadLow(2), outletLoadNearOverload(3), outletLoadOverload(4)}read-onlymandatory
airConditioners
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13
airFM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1
airFMIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.1
airFMIdentName
OBJECT-TYPE
A character string identifying the device.
1.3.6.1.4.1.318.1.1.13.1.1.1DisplayStringread-writemandatory
airFMIdentTableSize
OBJECT-TYPE
The number of entries in the airFMIdentTable.
1.3.6.1.4.1.318.1.1.13.1.1.2INTEGERread-onlymandatory
airFMIdentTable
OBJECT-TYPE
Allows for getting identification information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.1.3not-accessiblemandatory
airFMIdentEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.1.3.1not-accessiblemandatory
airFMIdentModuleIndex
OBJECT-TYPE
The index of the module information.
1.3.6.1.4.1.318.1.1.13.1.1.3.1.1INTEGERread-onlymandatory
airFMIdentModuleModelNumber
OBJECT-TYPE
A character string identifying the model number.
1.3.6.1.4.1.318.1.1.13.1.1.3.1.2DisplayStringread-onlymandatory
airFMIdentModuleDateOfMfg
OBJECT-TYPE
A character string identifying the manufacture date.
1.3.6.1.4.1.318.1.1.13.1.1.3.1.3DisplayStringread-onlymandatory
airFMIdentModuleSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.1.1.3.1.4DisplayStringread-onlymandatory
airFMIdentModuleFirmwareRev
OBJECT-TYPE
A character string identifying the firmware revision.
1.3.6.1.4.1.318.1.1.13.1.1.3.1.5DisplayStringread-onlymandatory
airFMIdentModuleHardwareRev
OBJECT-TYPE
A character string identifying the hardware revision.
1.3.6.1.4.1.318.1.1.13.1.1.3.1.6DisplayStringread-onlymandatory
airFMIdentLocation
OBJECT-TYPE
A character string identifying the location of the device.
1.3.6.1.4.1.318.1.1.13.1.1.4DisplayStringread-writemandatory
airFMIdentContact
OBJECT-TYPE
A character string identifying the person to contact regarding the device.
1.3.6.1.4.1.318.1.1.13.1.1.5DisplayStringread-writemandatory
airFMStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.2
airFMStatusSystemOn
OBJECT-TYPE
The operating state of the system. This OID has been deprecated in favor of airFMGroupSysStatus.
1.3.6.1.4.1.318.1.1.13.1.2.1INTEGER {statusOn(1), statusOff(2)}read-onlymandatory
airFMStatusSystemAverageRetTempC
OBJECT-TYPE
The system average return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgReturnTempC.
1.3.6.1.4.1.318.1.1.13.1.2.2INTEGERread-onlymandatory
airFMStatusSystemAverageRetTempF
OBJECT-TYPE
The system average return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgReturnTempF.
1.3.6.1.4.1.318.1.1.13.1.2.3INTEGERread-onlymandatory
airFMStatusSystemAverageRetHum
OBJECT-TYPE
The system average return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgReturnHum.
1.3.6.1.4.1.318.1.1.13.1.2.4INTEGERread-onlymandatory
airFMStatusSystemActionTempC
OBJECT-TYPE
The system action air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysCtrlTempC.
1.3.6.1.4.1.318.1.1.13.1.2.5INTEGERread-onlymandatory
airFMStatusSystemActionTempF
OBJECT-TYPE
The system action air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysCtrlTempF.
1.3.6.1.4.1.318.1.1.13.1.2.6INTEGERread-onlymandatory
airFMStatusSystemActionHum
OBJECT-TYPE
The system action air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysCtrlHum.
1.3.6.1.4.1.318.1.1.13.1.2.7INTEGERread-onlymandatory
airFMStatusSystemRemoteHighTempC
OBJECT-TYPE
The system remote high air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMaxRemoteTempC.
1.3.6.1.4.1.318.1.1.13.1.2.8INTEGERread-onlymandatory
airFMStatusSystemRemoteHighTempF
OBJECT-TYPE
The system remote high air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMaxRemoteTempF.
1.3.6.1.4.1.318.1.1.13.1.2.9INTEGERread-onlymandatory
airFMStatusSystemRemoteAvgTempC
OBJECT-TYPE
The system remote average air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysAvgRemoteTempC.
1.3.6.1.4.1.318.1.1.13.1.2.10INTEGERread-onlymandatory
airFMStatusSystemRemoteAvgTempF
OBJECT-TYPE
The system remote average air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysAvgRemoteTempF.
1.3.6.1.4.1.318.1.1.13.1.2.11INTEGERread-onlymandatory
airFMStatusSystemRemoteAvgHum
OBJECT-TYPE
The system remote average air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMSysAvgRemoteHum.
1.3.6.1.4.1.318.1.1.13.1.2.12INTEGERread-onlymandatory
airFMStatusSystemRemoteLowTempC
OBJECT-TYPE
The system remote low air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMSysMinRemoteTempC.
1.3.6.1.4.1.318.1.1.13.1.2.13INTEGERread-onlymandatory
airFMStatusSystemRemoteLowTempF
OBJECT-TYPE
The system remote low air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMSysMinRemoteTempF.
1.3.6.1.4.1.318.1.1.13.1.2.14INTEGERread-onlymandatory
airFMStatusSystemCoolingEnabled
OBJECT-TYPE
The state of the system cooling function enable. This OID has been deprecated in favor of airFMSysCoolState.
1.3.6.1.4.1.318.1.1.13.1.2.15INTEGER {enabledYes(1), enabledNo(2)}read-onlymandatory
airFMStatusSystemReheatingEnabled
OBJECT-TYPE
The state of the system reheating function enable. This OID has been deprecated in favor of airFMSysReheatState.
1.3.6.1.4.1.318.1.1.13.1.2.16INTEGER {enabledYes(1), enabledNo(2)}read-onlymandatory
airFMStatusSystemHumidifyEnabled
OBJECT-TYPE
The state of the system humidify function enable. This OID has been deprecated in favor of airFMSysHumState.
1.3.6.1.4.1.318.1.1.13.1.2.17INTEGER {enabledYes(1), enabledNo(2)}read-onlymandatory
airFMStatusSystemDehumidifyEnabled
OBJECT-TYPE
The state of the system dehumidify function enable. This OID has been deprecated in favor of airFMSysDehumState.
1.3.6.1.4.1.318.1.1.13.1.2.18INTEGER {enabledYes(1), enabledNo(2)}read-onlymandatory
airFMStatusModuleTableSize
OBJECT-TYPE
The number of entries in the airFMStatusModuleTable.
1.3.6.1.4.1.318.1.1.13.1.2.19INTEGERread-onlymandatory
airFMStatusModuleTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.2.20not-accessiblemandatory
airFMStatusModuleEntry
OBJECT-TYPE
The module to get status from.
1.3.6.1.4.1.318.1.1.13.1.2.20.1not-accessiblemandatory
airFMStatusModuleIndex
OBJECT-TYPE
The index of the module information.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.1INTEGERread-onlymandatory
airFMStatusModuleOutputCapacity
OBJECT-TYPE
The module output capacity in kilowatts. This OID has been deprecated in favor of airFMModOutputCapacity.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.2INTEGERread-onlymandatory
airFMStatusModuleSupplyTempC
OBJECT-TYPE
The module supply air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModSupplyTempC.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.3INTEGERread-onlymandatory
airFMStatusModuleSupplyTempF
OBJECT-TYPE
The module supply air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModSupplyTempF.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.4INTEGERread-onlymandatory
airFMStatusModuleSupplyHum
OBJECT-TYPE
The module supply air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModSupplyHum.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.5INTEGERread-onlymandatory
airFMStatusModuleReturnTempC
OBJECT-TYPE
The module return air temperature in tenths of degrees Celsius. This OID has been deprecated in favor of airFMModReturnTempC.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.6INTEGERread-onlymandatory
airFMStatusModuleReturnTempF
OBJECT-TYPE
The module return air temperature in tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModReturnTempF.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.7INTEGERread-onlymandatory
airFMStatusModuleReturnHum
OBJECT-TYPE
The module return air humidity in tenths of percent RH. This OID has been deprecated in favor of airFMModReturnHum.
1.3.6.1.4.1.318.1.1.13.1.2.20.1.8INTEGERread-onlymandatory
airFMGroup
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3
airFMGroupSysStatus
OBJECT-TYPE
The status of this system within the group.
1.3.6.1.4.1.318.1.1.13.1.3.1INTEGER {statusOnLine(1), statusIdle(2), statusLoadShare(3), statusOffLine(4), statusFailed(5), statusDisabled(6), statusUndefined(7)}read-onlymandatory
airFMGroupSysRuntime
OBJECT-TYPE
The number of hours the system has been running.
1.3.6.1.4.1.318.1.1.13.1.3.2INTEGERread-onlymandatory
airFMGroupSysRole
OBJECT-TYPE
The role of this system within the group.
1.3.6.1.4.1.318.1.1.13.1.3.3INTEGER {rolePrimary(1), roleBackup(2)}read-onlymandatory
airFMGroupSysRoles
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3.4
airFMGroupSysRolesTableSize
OBJECT-TYPE
The number of entries in the airFMGroupSysRolesTable.
1.3.6.1.4.1.318.1.1.13.1.3.4.1INTEGERread-onlymandatory
airFMGroupSysRolesTable
OBJECT-TYPE
Allows for getting information from each system in the group.
1.3.6.1.4.1.318.1.1.13.1.3.4.2not-accessiblemandatory
airFMGroupSysRolesEntry
OBJECT-TYPE
The system to get status from.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1not-accessiblemandatory
airFMGroupSysIndex
OBJECT-TYPE
The index of the system information.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.1INTEGERread-onlymandatory
airFMGroupSysRoleStatus
OBJECT-TYPE
The present mode of the System.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.2INTEGER {reserved1(1), reserved2(2), onLine(3), idle(4), loadShare(5), failed(6), offLine(7)}read-onlymandatory
airFMGroupSysPresentRole
OBJECT-TYPE
The present role of the System in a Group.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.3INTEGER {primary(1), backup(2)}read-onlymandatory
airFMGroupSysManualRoleSetting
OBJECT-TYPE
The manual role setting of the System in a Group. Only applies if Role Assignment Method is set to static (Manually Assigned Roles).
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.4INTEGER {primary(1), backup(2)}read-writemandatory
airFMGroupSysRunHours
OBJECT-TYPE
The total number of hours the System has been contributing to environmental control.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.5INTEGERread-onlymandatory
airFMGroupSysComm
OBJECT-TYPE
Indicates whether a system is communicating with the other Systems in the Group.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.6INTEGER {commLost(1), commEstablished(2)}read-onlymandatory
airFMGroupSysIPAddress
OBJECT-TYPE
The IP Address of the System.
1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.7IpAddressread-onlymandatory
airFMGroupSysRoleAssignment
OBJECT-TYPE
The method used to assign roles (i.e. Primary, Backup) to the Systems in a Group. staticManual: Manually assign Primary or Backup to regulate run hours across the Group. dynamicAutomatic: User indicates the number of Systems that will be assigned a primary role in this Group.
1.3.6.1.4.1.318.1.1.13.1.3.4.3INTEGER {staticManual(1), dynamicAutomatic(2)}read-writemandatory
airFMGroupAutoRoleNumPrimary
OBJECT-TYPE
The number of Systems assigned the 'primary' role in this Group. Only applies if Role Assignment Method is set to dynamic (Automatic Run Hour Balancing).
1.3.6.1.4.1.318.1.1.13.1.3.4.4INTEGER {one(1), two(2), three(3), four(4)}read-writemandatory
airFMGroupCfg
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3.5
airFMGroupCfgName
OBJECT-TYPE
A character string identifying the group name.
1.3.6.1.4.1.318.1.1.13.1.3.5.1DisplayStringread-writemandatory
airFMGroupCfgNumSystems
OBJECT-TYPE
The number of Systems in this Group.
1.3.6.1.4.1.318.1.1.13.1.3.5.2INTEGER {one(1), two(2), three(3), four(4)}read-writemandatory
airFMGroupCfgIdleBlower
OBJECT-TYPE
Blower behavior for backup Systems and Systems that have entered a failure mode.
1.3.6.1.4.1.318.1.1.13.1.3.5.3INTEGER {off(1), minimumSpeed(2), normalSpeed(3)}read-writemandatory
airFMGroupCfgShutdownSmoke
OBJECT-TYPE
If enabled, all Systems in the Group will shut down if smoke is detected.
1.3.6.1.4.1.318.1.1.13.1.3.5.4INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupCfgShutdownFire
OBJECT-TYPE
If enabled, all Systems in the Group will shut down if fire is detected.
1.3.6.1.4.1.318.1.1.13.1.3.5.5INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupCfgFailoverCommLoss
OBJECT-TYPE
Failover on Comm Loss enables an available backup System to run in place of a System that has lost communication with the Group.
1.3.6.1.4.1.318.1.1.13.1.3.5.6INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupCfgDmdFightStatus
OBJECT-TYPE
Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to a Load Sharing Request.
1.3.6.1.4.1.318.1.1.13.1.3.5.7INTEGER {off(1), on(2)}read-onlymandatory
airFMGroupCfgDmdFightSetting
OBJECT-TYPE
Demand Fighting prevents a System from engaging reheat in a Group where any System is cooling.
1.3.6.1.4.1.318.1.1.13.1.3.5.8INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupCfgSetpointShareStatus
OBJECT-TYPE
Demand Fighting and Setpoint Sharing are automatically enabled when a System is responding to Load Sharing Request.
1.3.6.1.4.1.318.1.1.13.1.3.5.9INTEGER {off(1), on(2)}read-onlymandatory
airFMGroupCfgSetpointShareSetting
OBJECT-TYPE
All Systems in the Group use the same setpoints.
1.3.6.1.4.1.318.1.1.13.1.3.5.10INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupCfgResetFieldServiceDefaults
OBJECT-TYPE
Setting this OID to reset(2) will reset all Group parameters, which can only be edited by a field service engineer, to their factory default values. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.13.1.3.5.11INTEGER {noOperation(1), reset(2)}read-writemandatory
airFMGroupLoadShare
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3.6
airFMGroupLoadShareCoolRequests
OBJECT-TYPE
Systems that are cooling may request assistance from other Systems in the Group.
1.3.6.1.4.1.318.1.1.13.1.3.6.1INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupLoadShareCoolThreshC
OBJECT-TYPE
Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.1.3.6.2INTEGERread-writemandatory
airFMGroupLoadShareCoolThreshF
OBJECT-TYPE
Temperature threshold at which a System will generate a load sharing request for cooling. Measured in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.1.3.6.3INTEGERread-writemandatory
airFMGroupLoadShareReheatRequests
OBJECT-TYPE
Systems that are reheating may request assistance from other Systems in the Group.
1.3.6.1.4.1.318.1.1.13.1.3.6.4INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupLoadShareReheatThreshC
OBJECT-TYPE
Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.1.3.6.5INTEGERread-writemandatory
airFMGroupLoadShareReheatThreshF
OBJECT-TYPE
Temperature threshold at which a System will generate a load sharing request for reheating. Measured in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.1.3.6.6INTEGERread-writemandatory
airFMGroupLoadShareHumRequests
OBJECT-TYPE
Systems that are humidifying may request humidification assistance from other Systems in the Group.
1.3.6.1.4.1.318.1.1.13.1.3.6.7INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupLoadShareHumThresh
OBJECT-TYPE
Humidity threshold at which a System will generate a load sharing request for humidification. Measured in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.1.3.6.8INTEGERread-writemandatory
airFMGroupLoadShareDehumRequests
OBJECT-TYPE
Systems that are dehumidifying may request assistance from other Systems in the Group.
1.3.6.1.4.1.318.1.1.13.1.3.6.9INTEGER {disable(1), enable(2)}read-writemandatory
airFMGroupLoadShareDehumThresh
OBJECT-TYPE
Humidity threshold at which a System will generate a load sharing request for dehumidification. Measured in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.1.3.6.10INTEGERread-writemandatory
airFMGroupFailover
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3.7
airFMGroupFailoverSys
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3.7.1
airFMGroupFailoverSysAnyMinorAlarm
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if any minor system alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.1INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysAnyMajorAlarm
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if any major system alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.2INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysHighEnvTemp
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the high environmental temperature alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.3INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysLowEnvTemp
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the low environmental temperature alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.4INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysHighEnvHum
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the high environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.5INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysLowEnvHum
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the low environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.6INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysFireAlarm
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the fire alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.7INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysSmokeAlarm
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the smoke alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.8INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysCommLost
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the system has lost comm. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.9INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysSupplySensorFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the supply sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.10INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysReturnSensorFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the return sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.11INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysPrimarySensorFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the primary sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.12INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysSecondarySensorFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the secondary sensor has failed. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.13INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverSysNoSensorsAvailable
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if no sensors are available. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.1.14INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverMod
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.3.7.2
airFMGroupFailoverModMaintRequired
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if maintenance is required on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.1INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModCoolFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if cooling has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.2INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModHumFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the humidifier has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.3INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModBlwrCntrl1Fail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if blower controller 1 has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.4INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModBlwrCntrl2Fail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if blower controller 2 has failed on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.5INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModHighFilterDP
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if a high filter differential pressure is present on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.6INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModHighSupplyTemp
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if a high supply temperature is active on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.7INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModLowSupplyTemp
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if a low supply temperature is active on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.8INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModLossOrLowAirFlow
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if there is a loss of air flow or low air flow on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.9INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModHumReplaceCylinder
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if a humidifier needs its cylinder replaced on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.10INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModAirBlockInterlockOpen
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the air block interlock is open on a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.11INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModWaterDetected
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if water is detected by a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.12INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMGroupFailoverModCondensatePumpFail
OBJECT-TYPE
Enabling this OID will cause the system to enter a failure state if the condensate pump has failed in a module. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.3.7.2.13INTEGER {notApplicable(1), disable(2), enable(3)}read-writemandatory
airFMSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4
airFMSysStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.1
airFMSysNumber
OBJECT-TYPE
The number of the system within the group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.1INTEGER {notApplicable(1), one(2), two(3), three(4), four(5)}read-onlymandatory
airFMSysPresentStatus
OBJECT-TYPE
The present mode of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.2INTEGER {notApplicable(1), reserved1(2), reserved2(3), onLine(4), idle(5), loadShare(6), failed(7), offLine(8)}read-onlymandatory
airFMSysPresentRole
OBJECT-TYPE
The present role of the System in the Group. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.3INTEGER {notApplicable(1), primary(2), backup(3)}read-onlymandatory
airFMSysRunHours
OBJECT-TYPE
The total number of hours the System has been contributing to environmental control. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.4INTEGERread-onlymandatory
airFMSysCoilFluidTempC
OBJECT-TYPE
The temperature of the coolant at the fluid coil inlet. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.5INTEGERread-onlymandatory
airFMSysCoilFluidTempF
OBJECT-TYPE
The temperature of the coolant at the fluid coil inlet. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.6INTEGERread-onlymandatory
airFMSysHotWaterTempC
OBJECT-TYPE
The hot water temperature. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.7INTEGERread-onlymandatory
airFMSysHotWaterTempF
OBJECT-TYPE
The hot water temperature. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.8INTEGERread-onlymandatory
airFMSysAvgReturnTempC
OBJECT-TYPE
The average return temperature calculated from all present modules. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.9INTEGERread-onlymandatory
airFMSysAvgReturnTempF
OBJECT-TYPE
The average return temperature calculated from all present modules. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.10INTEGERread-onlymandatory
airFMSysAvgReturnHum
OBJECT-TYPE
The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.11INTEGERread-onlymandatory
airFMSysAvgRemoteTempC
OBJECT-TYPE
The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.12INTEGERread-onlymandatory
airFMSysAvgRemoteTempF
OBJECT-TYPE
The average temperature calculated from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.13INTEGERread-onlymandatory
airFMSysAvgRemoteHum
OBJECT-TYPE
The average return humidity calculated from all present modules. Measured in tenths of percent RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.14INTEGERread-onlymandatory
airFMSysMaxRemoteTempC
OBJECT-TYPE
The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.15INTEGERread-onlymandatory
airFMSysMaxRemoteTempF
OBJECT-TYPE
The maximum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.16INTEGERread-onlymandatory
airFMSysMinRemoteTempC
OBJECT-TYPE
The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.17INTEGERread-onlymandatory
airFMSysMinRemoteTempF
OBJECT-TYPE
The minimum temperature reading from all operational remote sensors. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.18INTEGERread-onlymandatory
airFMSysTempCtrlMethod
OBJECT-TYPE
The method of environment temperature control selected to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.19INTEGER {notApplicable(1), avgReturn(2), avgRemote(3), maxRemote(4)}read-onlymandatory
airFMSysActualTempCtrlMethod
OBJECT-TYPE
The actual method of environment temperature control being used to regulate the temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.20INTEGER {notApplicable(1), avgReturn(2), avgRemote(3), maxRemote(4)}read-onlymandatory
airFMSysHumCtrlMethod
OBJECT-TYPE
The method of environment humidity control selected to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.21INTEGER {notApplicable(1), avgReturnRH(2), avgReturnDewPt(3), avgRemoteRH(4), avgRemoteDewPt(5)}read-onlymandatory
airFMSysActualHumCtrlMethod
OBJECT-TYPE
The actual method of environment humidity control being used to regulate the humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.22INTEGER {notApplicable(1), avgReturnRH(2), avgReturnDewPt(3), avgRemoteRH(4), avgRemoteDewPt(5)}read-onlymandatory
airFMSysCtrlTempC
OBJECT-TYPE
The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.23INTEGERread-onlymandatory
airFMSysCtrlTempF
OBJECT-TYPE
The system environmental control air temperature from the sensor denoted by airFMSysActualTempCtrl. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.24INTEGERread-onlymandatory
airFMSysCtrlHum
OBJECT-TYPE
The system environmental control air humidity from the sensor denoted by airFMSysActualHumCtrl. Measured in percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.1.25INTEGERread-onlymandatory
airFMSysDemands
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.2
airFMSysDXCoolingDmd
OBJECT-TYPE
The direct expansion cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.1INTEGERread-onlymandatory
airFMSysDXDehumDmd
OBJECT-TYPE
The direct expansion dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.2INTEGERread-onlymandatory
airFMSysDXActualCoolDehum
OBJECT-TYPE
The direct expansion cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.3INTEGERread-onlymandatory
airFMSysCoilFluidCoolDmd
OBJECT-TYPE
The fluid coil cooling output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.4INTEGERread-onlymandatory
airFMSysCoilFluidDehumDmd
OBJECT-TYPE
The fluid coil dehumidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.5INTEGERread-onlymandatory
airFMSysCoilFluidActualCoolDehum
OBJECT-TYPE
The fluid coil cooling or dehumidification output measured by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.6INTEGERread-onlymandatory
airFMSysElectricReheatDmd
OBJECT-TYPE
The electric reheating output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.7INTEGERread-onlymandatory
airFMSysActualElectricReheat
OBJECT-TYPE
The electric reheating output of the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.8INTEGERread-onlymandatory
airFMSysSteamHotGasReheatDmd
OBJECT-TYPE
The steam, hot water, or hot gas reheating output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.9INTEGER {notApplicable(1), off(2), on(3)}read-onlymandatory
airFMSysActualSteamHotGasReheat
OBJECT-TYPE
The steam, hot water, or hot gas reheating output of the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.10INTEGER {notApplicable(1), off(2), on(3)}read-onlymandatory
airFMSysSteamElectrodeHumDmd
OBJECT-TYPE
The steam electrode humidification output demanded by the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.11INTEGERread-onlymandatory
airFMSysActualSteamElectrodeHum
OBJECT-TYPE
The average steam electrode humidification output measured for the Modules in the System. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.12INTEGERread-onlymandatory
airFMSysSteamHumDmd
OBJECT-TYPE
The steam humidification output demanded by the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.13INTEGER {notApplicable(1), off(2), on(3)}read-onlymandatory
airFMSysActualSteamHum
OBJECT-TYPE
The steam humidification output for the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.2.14INTEGER {notApplicable(1), off(2), on(3)}read-onlymandatory
airFMSysSetup
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.3
airFMSysNumModules
OBJECT-TYPE
The number of Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.1INTEGER {notApplicable(1), one(2), two(3), three(4)}read-onlymandatory
airFMSysNumPCIOMs
OBJECT-TYPE
The number of Programmable Customer Input/Output Modules (PCIOMs) installed in the Main Module of this System. Each PCIOM adds four input contacts and four output relays to the System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.2INTEGER {notApplicable(1), one(2), two(3), three(4), four(5)}read-onlymandatory
airFMSysMainsVlt
OBJECT-TYPE
The mains voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.3DisplayStringread-onlymandatory
airFMSysUPSVlt
OBJECT-TYPE
The UPS voltage for the Modules in this System. A value of N/A indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.4DisplayStringread-onlymandatory
airFMSysCoilCfg
OBJECT-TYPE
The type of cooling coils installed in the Modules in this System: DX coil, DX and MultiCool (chilled water) coils, DX and Economizer coils, or only a Chilled Liquid coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.5INTEGER {notApplicable(1), dx(2), econ(3), multicool(4), chilledWater(5)}read-onlymandatory
airFMSysRefrigType
OBJECT-TYPE
The type of refrigerant used by each compressor in the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.6INTEGER {notApplicable(1), r22(2), r407C(3)}read-onlymandatory
airFMSysHeatRejection
OBJECT-TYPE
The method the Modules in this System use to transfer heat away from the refrigerant. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.7INTEGER {notApplicable(1), airCooled(2), waterCooled(3), glycolCooled(4)}read-onlymandatory
airFMSysDischAirPtrn
OBJECT-TYPE
The discharge air pattern for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.8INTEGER {notApplicable(1), upFlow(2), downFlow(3), horizFlow(4)}read-onlymandatory
airFMSysAirFltr
OBJECT-TYPE
The type of air filters (standard or high efficiency) installed in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.9INTEGER {notApplicable(1), standard(2), highEfficiency(3)}read-onlymandatory
airFMSysFlowSwitch
OBJECT-TYPE
The location of the optional flow switch. None: No flow switch is installed in this System. DX: Coolant input to the heat exchanger (condenser). MultiCool: Chilled water input to the MultiCool coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.10INTEGER {notApplicable(1), none(2), dxEcon(3), multiCoolChillWater(4)}read-onlymandatory
airFMSysCoilFluidVlvAct
OBJECT-TYPE
The type of valve actuator installed on the coil fluid valve. The coil fluid valve controls the flow of coolant into a fluid cooling coil, such as a MultiCool or Economizer coil. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.11INTEGER {notApplicable(1), none(2), springAnalog(3), floatingControl(4)}read-onlymandatory
airFMSysCoilFluidVlvType
OBJECT-TYPE
The type of coil fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.12INTEGER {notApplicable(1), twoWay(2), threeWay(3)}read-onlymandatory
airFMSysCndsrFluidVlvAct
OBJECT-TYPE
The type of valve actuator installed on the Condenser fluid valve. The Condenser fluid valve controls the flow of coolant into the heat exchanger (condenser) to regulate head pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.13INTEGER {notApplicable(1), none(2), floatingControl(3)}read-onlymandatory
airFMSysCndsrFluidVlvType
OBJECT-TYPE
The type of Condenser fluid valve installed for the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.14INTEGER {notApplicable(1), twoWay(2), threeWay(3)}read-onlymandatory
airFMSysHotWaterVlvAct
OBJECT-TYPE
The type of valve actuator installed on the hot water valve. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.3.15INTEGER {notApplicable(1), none(2), springAnalog(3), floatingControl(4)}read-onlymandatory
airFMSysNumRemoteSensors
OBJECT-TYPE
The number of remote sensors detected by the system.
1.3.6.1.4.1.318.1.1.13.1.4.3.16INTEGERread-onlymandatory
airFMSysConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.4
airFMSysPrimaryControlSensor
OBJECT-TYPE
Selects whether return or remote sensors will control the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.1INTEGER {notApplicable(1), return(2), remote(3)}read-writemandatory
airFMSysRemoteSensorData
OBJECT-TYPE
Selects whether average temperature or max temperature will be used when remote sensors are selected for control of the system. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.2INTEGER {notApplicable(1), average(2), maximum(3)}read-writemandatory
airFMSysFastStartup
OBJECT-TYPE
Minimizes the time for the cooling process to begin after other delay constraints have been met. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysStartupDelay
OBJECT-TYPE
Set the delay that begins when power is applied and ends when the System starts. This allows you to create a staged restart among your Systems after a power loss. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.4INTEGERread-writemandatory
airFMSysModeDelay
OBJECT-TYPE
Set the delay between starting the blowers and engaging the modes. It allows the sensors to read room conditions accurately and allows the controller to check for major alarms before engaging a mode. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.5INTEGERread-writemandatory
airFMSysCommLossShutdownDelay
OBJECT-TYPE
Set the delay between an Expansion Module losing communication with the Main Module and the Expansion Module shutting down. A value of -1 will keep the Expansion Module running after a communication loss. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.6INTEGERread-writemandatory
airFMSysResetSysFailure
OBJECT-TYPE
Setting this OID to reset(2) will allows the system to return from any failure condition, if the failure(s) have cleared. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.7INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMSysResetUserDflts
OBJECT-TYPE
Setting this OID to reset(2) will reset all system parameters that can be edited by the user to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.8INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMSysResetFldSrvcDflts
OBJECT-TYPE
Setting this OID to reset(2) will reset all system parameters that can only be edited by the field service engineer to their factory default values. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.9INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMSysResetRunHours
OBJECT-TYPE
Setting this OID to reset(2) will reset the system Run Hours. Getting this OID will do nothing and return the noOperation(1) value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.4.10INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMSysCooling
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.5
airFMSysCompMinOnTime
OBJECT-TYPE
Set the minimum time the compressor continues to operate after it is started. The delay protects the compressor from damage. Caution: Reducing this delay shortens compressor life. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.1INTEGERread-writemandatory
airFMSysCompMinOffTime
OBJECT-TYPE
Set the minimum time the compressor will remain off after it ceases operation. The delay protects the compressor from damage. Caution: Reducing this delay shortens compressor life. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.2INTEGERread-writemandatory
airFMSysCompRotPeriod
OBJECT-TYPE
Set how often to perform compressor runtime balancing. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.3INTEGERread-writemandatory
airFMSysEconIsolVlvOpenDelay
OBJECT-TYPE
Set the delay between opening the Economizer Isolator output relay and engaging the compressors. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.4INTEGERread-writemandatory
airFMSysEconIsolVlvCloseDelay
OBJECT-TYPE
Set the delay between disengaging the compressor and closing the Economizer Isolator output relay. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.5INTEGERread-writemandatory
airFMSysCndsrFluidVlvCloseDelay
OBJECT-TYPE
Set the time the condenser valve remains open after the compressors disengage. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.6INTEGERread-writemandatory
airFMSysInterstageDelay
OBJECT-TYPE
The DX interstage delay allows the first compressor's cooling to take effect before engaging the second compressor. This prevents the second compressor from cycling on and off excessively. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.7INTEGERread-writemandatory
airFMSysCoolState
OBJECT-TYPE
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysCoolEssFunction
OBJECT-TYPE
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.9INTEGER {notApplicable(1), yes(2), no(3)}read-writemandatory
airFMSysCoolSetpointC
OBJECT-TYPE
The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.10INTEGERread-writemandatory
airFMSysCoolSetpointF
OBJECT-TYPE
The target value for the selected control sensor air for this mode. It must be at least 1.0 C above the reheat setpoint if a heater is installed. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.11INTEGERread-writemandatory
airFMSysCoolDeadbandC
OBJECT-TYPE
The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.12INTEGERread-writemandatory
airFMSysCoolDeadbandF
OBJECT-TYPE
The temperature range that controls output when the selected control sensor temperature is above the setpoint. At the top of this range, the cool mode outputs at 100%. The deadband does not apply to PID- controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.13INTEGERread-writemandatory
airFMSysCoolEconIsolFunction
OBJECT-TYPE
Set the Economizer Automatic Coolant Isolation valve to enabled or disabled. This valve anticipates a cooling demand and opens the coil fluid valve. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysSuctPresCompensation
OBJECT-TYPE
Set the Suction Pressure Compensation to enabled or disabled. This function attempts to keep the suction pressure from exceeding 95 psi. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysCoilFluidActivThreshC
OBJECT-TYPE
The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.16INTEGERread-writemandatory
airFMSysCoilFluidActivThreshF
OBJECT-TYPE
The minimum coolant temperature required to use the optional MultiCool or Economizer coil. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.17INTEGERread-writemandatory
airFMSysCoilFluidActivDeadbandC
OBJECT-TYPE
The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the deadband. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.18INTEGERread-writemandatory
airFMSysCoilFluidActivDeadbandF
OBJECT-TYPE
The controller will disengage the MultiCool or Economizer coil when the coolant temperature reaches the coil fluid temperature activation threshold plus the deadband. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.19INTEGERread-writemandatory
airFMSysCoolPIDMethod
OBJECT-TYPE
Set the multipliers that the PID algorithm will use to calculate the cool output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.20INTEGER {notApplicable(1), p(2), pi(3), pid(4)}read-writemandatory
airFMSysCoolPIDGainP
OBJECT-TYPE
Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.21INTEGERread-writemandatory
airFMSysCoolPIDResetRateI
OBJECT-TYPE
Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.22INTEGERread-writemandatory
airFMSysCoolPIDDerivativeD
OBJECT-TYPE
Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.5.23INTEGERread-writemandatory
airFMSysHumidify
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.6
airFMSysHumState
OBJECT-TYPE
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.1INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysHumEssFunction
OBJECT-TYPE
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.2INTEGER {notApplicable(1), yes(2), no(3)}read-writemandatory
airFMSysHumSetpoint
OBJECT-TYPE
The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH below the dehumidification setpoint. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.3INTEGERread-writemandatory
airFMSysHumDeadband
OBJECT-TYPE
The humidity range that controls output when the selected control sensor humidity is below the setpoint. At the top of this range, the humidification mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.4INTEGERread-writemandatory
airFMSysHumCtrlSetting
OBJECT-TYPE
Set the method to control the humidity in the room. The two methods are Relative Humidity (RH) or Dew Point of the selected control sensor air. The dew point method helps correct for hot spots near the selected control sensors. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.5INTEGER {notApplicable(1), relativeHum(2), dewPoint(3)}read-writemandatory
airFMSysActualHumCtrl
OBJECT-TYPE
The humidity control method the system is using. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.6INTEGER {notApplicable(1), relativeHum(2), dewPoint(3)}read-onlymandatory
airFMSysHumSensBand
OBJECT-TYPE
The percentage of relative humidity below the setpoint at which the humidifier will output at 100% of capacity. Measured in percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.6.7INTEGERread-writemandatory
airFMSysDehumidify
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.7
airFMSysDehumState
OBJECT-TYPE
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.1INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysDehumEssFunction
OBJECT-TYPE
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.2INTEGER {notApplicable(1), yes(2), no(3)}read-writemandatory
airFMSysDehumSetpoint
OBJECT-TYPE
The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH above the humidification setpoint if a humidifier is installed. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.3INTEGERread-writemandatory
airFMSysDehumDeadband
OBJECT-TYPE
The humidity range above the setpoint at which the dehumidification mode will output at 100%. The deadband does not apply to PID controlled modes. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.4INTEGERread-writemandatory
airFMSysDehumCapacity
OBJECT-TYPE
Set the dehumidification mode to use either half of the cooling coil or the full coil when dehumidifying the room. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.5INTEGER {notApplicable(1), half(2), full(3)}read-writemandatory
airFMSysDehumPIDMethod
OBJECT-TYPE
Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.6INTEGER {notApplicable(1), p(2), pi(3), pid(4)}read-writemandatory
airFMSysDehumPIDGainP
OBJECT-TYPE
Set the proportional multiplier to correct for differences between the selected control sensor actual humidity and the setpoint. Measured in %/%RH. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.7INTEGERread-writemandatory
airFMSysDehumPIDResetRateI
OBJECT-TYPE
Set the integral multiplier to correct for the proportional offset. Measured in %/(%RH * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.8INTEGERread-writemandatory
airFMSysDehumPIDDerivativeD
OBJECT-TYPE
Set the derivative multiplier to counteract overshoot and droop during changes in the room humidity. Measure in %/(%RH / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.7.9INTEGERread-writemandatory
airFMSysReheat
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.8
airFMSysReheatState
OBJECT-TYPE
Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they are disabled. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.1INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysReheatEssFunction
OBJECT-TYPE
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.2INTEGER {notApplicable(1), yes(2), no(3)}read-writemandatory
airFMSysReheatSetpointC
OBJECT-TYPE
The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.3INTEGERread-writemandatory
airFMSysReheatSetpointF
OBJECT-TYPE
The target value for the selected control sensor air for this mode. It must be at least 1.0 C below the cooling setpoint. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.4INTEGERread-writemandatory
airFMSysReheatDeadbandC
OBJECT-TYPE
The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.5INTEGERread-writemandatory
airFMSysReheatDeadbandF
OBJECT-TYPE
The temperature range that controls output when the selected control sensor temperature is below the setpoint. At the bottom of this range, the reheat mode outputs at 100%. The deadband does not apply to PID-controlled modes. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.6INTEGERread-writemandatory
airFMSysReheatPIDMethod
OBJECT-TYPE
Set the multipliers that the PID algorithm will use to calculate the output. Proportional, Proportional + Integral, or Proportional + Integral + Derivative. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.7INTEGER {notApplicable(1), p(2), pi(3), pid(4)}read-writemandatory
airFMSysReheatPIDGainP
OBJECT-TYPE
Set the proportional multiplier to correct for differences between the selected control sensor actual temperature and the setpoint. Measured in %/C. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.8INTEGERread-writemandatory
airFMSysReheatPIDResetRateI
OBJECT-TYPE
Set the integral multiplier to correct for the proportional offset. Measured in %/(C * min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.9INTEGERread-writemandatory
airFMSysReheatPIDDerivativeD
OBJECT-TYPE
Set the derivative multiplier to counteract overshoot and droop during changes in the room load. Measured in %/(C / min). A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.8.10INTEGERread-writemandatory
airFMSysThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.9
airFMSysHighSplyTempC
OBJECT-TYPE
The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.1INTEGERread-writemandatory
airFMSysHighSplyTempF
OBJECT-TYPE
The high temperature threshold for air blown into the room (supply). If the supply temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.2INTEGERread-writemandatory
airFMSysLowSplyTempC
OBJECT-TYPE
The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.3INTEGERread-writemandatory
airFMSysLowSplyTempF
OBJECT-TYPE
The low temperature threshold for air blown into the room (supply). If the supply temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.4INTEGERread-writemandatory
airFMSysHighCoilFluidTempC
OBJECT-TYPE
The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.5INTEGERread-writemandatory
airFMSysHighCoilFluidTempF
OBJECT-TYPE
The high temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.6INTEGERread-writemandatory
airFMSysLowCoilFluidTempC
OBJECT-TYPE
The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.7INTEGERread-writemandatory
airFMSysLowCoilFluidTempF
OBJECT-TYPE
The low temperature threshold for coolant at the inlet to the fluid coil. If the fluid coil coolant temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.8INTEGERread-writemandatory
airFMSysHighCtrlTempC
OBJECT-TYPE
The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.9INTEGERread-writemandatory
airFMSysHighCtrlTempF
OBJECT-TYPE
The high temperature threshold for air monitored by the System. If the temperature exceeds the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.10INTEGERread-writemandatory
airFMSysLowCtrlTempC
OBJECT-TYPE
The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.11INTEGERread-writemandatory
airFMSysLowCtrlTempF
OBJECT-TYPE
The low temperature threshold for air monitored by the System. If the temperature drops below the threshold, an alarm will occur. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.12INTEGERread-writemandatory
airFMSysHighCtrlHum
OBJECT-TYPE
The high humidity threshold for air monitored by the System. If the humidity exceeds the threshold, an alarm will occur. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.13INTEGERread-writemandatory
airFMSysLowCtrlHum
OBJECT-TYPE
The low humidity threshold for air monitored by the System. If the humidity drops below the threshold, an alarm will occur. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.14INTEGERread-writemandatory
airFMSysTempAlarmDelay
OBJECT-TYPE
The amount of time the blower must be on before a temperature alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.15INTEGERread-writemandatory
airFMSysHumAlarmDelay
OBJECT-TYPE
The amount of time the blower must be on before a humidity alarm can be issued. Measured in seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.9.16INTEGERread-writemandatory
airFMSysInputs
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.10
airFMSysInputTableSize
OBJECT-TYPE
The number of entries in the airFMSysInputTable.
1.3.6.1.4.1.318.1.1.13.1.4.10.1INTEGERread-onlymandatory
airFMSysInputTable
OBJECT-TYPE
Allows for getting information from each input contact.
1.3.6.1.4.1.318.1.1.13.1.4.10.2not-accessiblemandatory
airFMSysInputEntry
OBJECT-TYPE
The input contact to obtain status from.
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1not-accessiblemandatory
airFMSysInputIndex
OBJECT-TYPE
The number designator of the Input Contact.
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.1INTEGERread-onlymandatory
airFMSysInputName
OBJECT-TYPE
The configurable name for the Input Contact. Maximum text input is 13 characters.
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.2DisplayStringread-writemandatory
airFMSysInputStatus
OBJECT-TYPE
The state of this contact: Open or Closed. A violation will occur when this relay is not in its normal state.
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.3INTEGER {open(1), closed(2)}read-onlymandatory
airFMSysInputNormalState
OBJECT-TYPE
Set the normal state of this contact (the state when no alarm/event exists).
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.4INTEGER {open(1), closed(2)}read-writemandatory
airFMSysInputDelay
OBJECT-TYPE
Set the delay between this contact exiting its normal state and an alarm being triggered. Measured in seconds.
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.5INTEGERread-writemandatory
airFMSysInputAlarmAction
OBJECT-TYPE
Sets the behavior for this contact when it exits its normal state.
1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.6INTEGER {statusOnly(1), minor(2), major(3), remoteRunStop(4), nonessStop(5), immShutdown(6)}read-writemandatory
airFMSysOutputs
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.11
airFMSysOutputTableSize
OBJECT-TYPE
The number of entries in the airFMSysOutputTable.
1.3.6.1.4.1.318.1.1.13.1.4.11.1INTEGERread-onlymandatory
airFMSysOutputTable
OBJECT-TYPE
Allows for getting information from each output relay.
1.3.6.1.4.1.318.1.1.13.1.4.11.2not-accessiblemandatory
airFMSysOutputEntry
OBJECT-TYPE
The output relay to obtain status from.
1.3.6.1.4.1.318.1.1.13.1.4.11.2.1not-accessiblemandatory
airFMSysOutputIndex
OBJECT-TYPE
The number designator of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.1INTEGERread-onlymandatory
airFMSysOutputStatus
OBJECT-TYPE
The state of this relay: Open or Closed. A violation will occur when this relay is not in its normal state.
1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.2INTEGER {open(1), closed(2)}read-onlymandatory
airFMSysOutputNormalState
OBJECT-TYPE
Set the normal state of this relay (the state when no alarm/event exists).
1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.3INTEGER {open(1), closed(2)}read-writemandatory
airFMSysAlarmMap
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12
airFMSysAlarmMapSys
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12.1
airFMSysAlarmMapSysTableSize
OBJECT-TYPE
The number of entries in the airFMSysAlarmMapSysTable.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.1INTEGERread-onlymandatory
airFMSysAlarmMapSysTable
OBJECT-TYPE
Allows for getting alarm map information.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2not-accessiblemandatory
airFMSysAlarmMapSysEntry
OBJECT-TYPE
The system alarm map type to reference.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1not-accessiblemandatory
airFMSysAlarmMapSysOutputIndex
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.1INTEGERread-onlymandatory
airFMSysAlarmMapSysAnyAlarm
OBJECT-TYPE
System alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.2INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSystemOn
OBJECT-TYPE
System alarm map setting for System On. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSystemOffline
OBJECT-TYPE
System alarm map setting for System Offline. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.4INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysHighEnvTemp
OBJECT-TYPE
System alarm map setting for High Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.5INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysLowEnvTemp
OBJECT-TYPE
System alarm map setting for Low Environmental Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.6INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysHighEnvHum
OBJECT-TYPE
System alarm map setting for High Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.7INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysLowEnvHum
OBJECT-TYPE
System alarm map setting for Low Environmental Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysFireDet
OBJECT-TYPE
System alarm map setting for Fire Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.9INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysSmokeDet
OBJECT-TYPE
System alarm map setting for Smoke Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.10INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysEconIsol
OBJECT-TYPE
System alarm map setting for Econ Isolator. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.11INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysSupplySensFail
OBJECT-TYPE
System alarm map setting for Supply Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.12INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysReturnSensFail
OBJECT-TYPE
System alarm map setting for Return Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.13INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysRemSensRemoved
OBJECT-TYPE
System alarm map setting for Remote Sensor Removed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysPrimSensFail
OBJECT-TYPE
System alarm map setting for Primary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysSecSensFail
OBJECT-TYPE
System alarm map setting for Secondary Sensor Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.16INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapSysSecSensActive
OBJECT-TYPE
System alarm map setting for Secondary Sensor Active. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.17INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainMod
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12.2
airFMSysAlarmMapMainModTableSize
OBJECT-TYPE
The number of entries in the airFMSysAlarmMapMainModTable.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.1INTEGERread-onlymandatory
airFMSysAlarmMapMainModTable
OBJECT-TYPE
Allows for getting alarm map information.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2not-accessiblemandatory
airFMSysAlarmMapMainModEntry
OBJECT-TYPE
The main module alarm map type to reference.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1not-accessiblemandatory
airFMSysAlarmMapMainModOutputIndex
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.1INTEGERread-onlymandatory
airFMSysAlarmMapMainModAnyAlarm
OBJECT-TYPE
Main Module alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.2INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModMaintReq
OBJECT-TYPE
Main Module alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModCoolFail
OBJECT-TYPE
Main Module alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.4INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModHighSupplyTemp
OBJECT-TYPE
Main Module alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.5INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModLowSupplyTemp
OBJECT-TYPE
Main Module alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.6INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModHumFail
OBJECT-TYPE
Main Module alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.7INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModHumReplCyl
OBJECT-TYPE
Main Module alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModCondPumpFail
OBJECT-TYPE
Main Module alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.9INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModBlwrCntl1Fail
OBJECT-TYPE
Main Module alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.10INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModBlwrCntl2Fail
OBJECT-TYPE
Main Module alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.11INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModHighFltrDP
OBJECT-TYPE
Main Module alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.12INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModLowAirFlow
OBJECT-TYPE
Main Module alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.13INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModAirBlckIntOpen
OBJECT-TYPE
Main Module alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapMainModWaterDetected
OBJECT-TYPE
Main Module alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12.3
airFMSysAlarmMapExpMod1TableSize
OBJECT-TYPE
The number of entries in the airFMSysAlarmMapExpMod1Table.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.1INTEGERread-onlymandatory
airFMSysAlarmMapExpMod1Table
OBJECT-TYPE
Allows for getting alarm map information.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2not-accessiblemandatory
airFMSysAlarmMapExpMod1Entry
OBJECT-TYPE
The expansion module 1 alarm map type to reference.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1not-accessiblemandatory
airFMSysAlarmMapExpMod1OutputIndex
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.1INTEGERread-onlymandatory
airFMSysAlarmMapExpMod1AnyAlarm
OBJECT-TYPE
Exp Module 1 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.2INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1MaintReq
OBJECT-TYPE
Exp Module 1 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1CoolFail
OBJECT-TYPE
Exp Module 1 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.4INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1HighSupplyTemp
OBJECT-TYPE
Exp Module 1 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.5INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1LowSupplyTemp
OBJECT-TYPE
Exp Module 1 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.6INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1HumFail
OBJECT-TYPE
Exp Module 1 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.7INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1HumReplCyl
OBJECT-TYPE
Exp Module 1 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1CondPumpFail
OBJECT-TYPE
Exp Module 1 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.9INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1BlwrCntl1Fail
OBJECT-TYPE
Exp Module 1 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.10INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1BlwrCntl2Fail
OBJECT-TYPE
Exp Module 1 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.11INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1HighFltrDP
OBJECT-TYPE
Exp Module 1 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.12INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1LowAirFlow
OBJECT-TYPE
Exp Module 1 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.13INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1AirBlckIntOpen
OBJECT-TYPE
Exp Module 1 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod1WaterDetected
OBJECT-TYPE
Exp Module 1 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12.4
airFMSysAlarmMapExpMod2TableSize
OBJECT-TYPE
The number of entries in the airFMSysAlarmMapExpMod2Table.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.1INTEGERread-onlymandatory
airFMSysAlarmMapExpMod2Table
OBJECT-TYPE
Allows for getting alarm map information.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2not-accessiblemandatory
airFMSysAlarmMapExpMod2Entry
OBJECT-TYPE
The expansion module 2 alarm map type to reference.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1not-accessiblemandatory
airFMSysAlarmMapExpMod2OutputIndex
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.1INTEGERread-onlymandatory
airFMSysAlarmMapExpMod2AnyAlarm
OBJECT-TYPE
Exp Module 2 alarm map setting for Any Alarm. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.2INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2MaintReq
OBJECT-TYPE
Exp Module 2 alarm map setting for Module Maintenance Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2CoolFail
OBJECT-TYPE
Exp Module 2 alarm map setting for Module Cooling Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.4INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2HighSupplyTemp
OBJECT-TYPE
Exp Module 2 alarm map setting for High Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.5INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2LowSupplyTemp
OBJECT-TYPE
Exp Module 2 alarm map setting for Low Supply Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.6INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2HumFail
OBJECT-TYPE
Exp Module 2 alarm map setting for Humidifier Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.7INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2HumReplCyl
OBJECT-TYPE
Exp Module 2 alarm map setting for Humidifier Replace Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2CondPumpFail
OBJECT-TYPE
Exp Module 2 alarm map setting for Condensate Pump Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.9INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2BlwrCntl1Fail
OBJECT-TYPE
Exp Module 2 alarm map setting for Blower Controller 1 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.10INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2BlwrCntl2Fail
OBJECT-TYPE
Exp Module 2 alarm map setting for Blower Controller 2 Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.11INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2HighFltrDP
OBJECT-TYPE
Exp Module 2 alarm map setting for High Filter Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.12INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2LowAirFlow
OBJECT-TYPE
Exp Module 2 alarm map setting for Low Air Flow. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.13INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2AirBlckIntOpen
OBJECT-TYPE
Exp Module 2 alarm map setting for Air Block Interlock Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapExpMod2WaterDetected
OBJECT-TYPE
Exp Module 2 alarm map setting for Water Detected. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12.5
airFMSysAlarmMapInputTableSize
OBJECT-TYPE
The number of entries in the airFMSysAlarmMapInputTable.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.1INTEGERread-onlymandatory
airFMSysAlarmMapInputTable
OBJECT-TYPE
Allows for getting alarm map information.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2not-accessiblemandatory
airFMSysAlarmMapInputEntry
OBJECT-TYPE
The input contact alarm map type to reference.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1not-accessiblemandatory
airFMSysAlarmMapInputOutputIndex
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.1INTEGERread-onlymandatory
airFMSysAlarmMapInput1
OBJECT-TYPE
Input contact 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.2INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput2
OBJECT-TYPE
Input contact 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput3
OBJECT-TYPE
Input contact 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.4INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput4
OBJECT-TYPE
Input contact 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.5INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput5
OBJECT-TYPE
Input contact 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.6INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput6
OBJECT-TYPE
Input contact 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.7INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput7
OBJECT-TYPE
Input contact 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput8
OBJECT-TYPE
Input contact 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.9INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput9
OBJECT-TYPE
Input contact 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.10INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput10
OBJECT-TYPE
Input contact 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.11INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput11
OBJECT-TYPE
Input contact 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.12INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput12
OBJECT-TYPE
Input contact 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.13INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput13
OBJECT-TYPE
Input contact 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput14
OBJECT-TYPE
Input contact 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput15
OBJECT-TYPE
Input contact 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.16INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapInput16
OBJECT-TYPE
Input contact 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.17INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.4.12.6
airFMSysAlarmMapOutputTableSize
OBJECT-TYPE
The number of entries in the airFMSysAlarmMapOutputTable.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.1INTEGERread-onlymandatory
airFMSysAlarmMapOutputTable
OBJECT-TYPE
Allows for getting alarm map information.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2not-accessiblemandatory
airFMSysAlarmMapOutputEntry
OBJECT-TYPE
The input contact alarm map type to reference.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1not-accessiblemandatory
airFMSysAlarmMapOutputIndex
OBJECT-TYPE
The index of the output relay.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.1INTEGERread-onlymandatory
airFMSysAlarmMapOutput1
OBJECT-TYPE
Output relay 1 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.2INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput2
OBJECT-TYPE
Output relay 2 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.3INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput3
OBJECT-TYPE
Output relay 3 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.4INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput4
OBJECT-TYPE
Output relay 4 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.5INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput5
OBJECT-TYPE
Output relay 5 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.6INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput6
OBJECT-TYPE
Output relay 6 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.7INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput7
OBJECT-TYPE
Output relay 7 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.8INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput8
OBJECT-TYPE
Output relay 8 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.9INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput9
OBJECT-TYPE
Output relay 9 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.10INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput10
OBJECT-TYPE
Output relay 10 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.11INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput11
OBJECT-TYPE
Output relay 11 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.12INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput12
OBJECT-TYPE
Output relay 12 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.13INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput13
OBJECT-TYPE
Output relay 13 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.14INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput14
OBJECT-TYPE
Output relay 14 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.15INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput15
OBJECT-TYPE
Output relay 15 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.16INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMSysAlarmMapOutput16
OBJECT-TYPE
Output relay 16 alarm map setting. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.17INTEGER {notApplicable(1), disabled(2), enabled(3)}read-writemandatory
airFMModule
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5
airFMModIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.1
airFMModIdentTableSize
OBJECT-TYPE
The number of entries in the airFMModIdentTable.
1.3.6.1.4.1.318.1.1.13.1.5.1.1INTEGERread-onlymandatory
airFMModIdentTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.1.2not-accessiblemandatory
airFMModIdentEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1not-accessiblemandatory
airFMModIdentModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.1INTEGERread-onlymandatory
airFMModModelNumber
OBJECT-TYPE
Model number of the Module.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.2DisplayStringread-onlymandatory
airFMModSerialNumber
OBJECT-TYPE
Unique identification number for this Module.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.3DisplayStringread-onlymandatory
airFMModManufactureDate
OBJECT-TYPE
Date the Module was manufactured.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.4DisplayStringread-onlymandatory
airFMModFirmwareRev
OBJECT-TYPE
Revision number of the firmware installed on this Module.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.5DisplayStringread-onlymandatory
airFMModHardwareRev
OBJECT-TYPE
Revision number of the hardware installed on this Module.
1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.6DisplayStringread-onlymandatory
airFMModStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.2
airFMModStatusTableSize
OBJECT-TYPE
The number of entries in the airFMModStatusTable.
1.3.6.1.4.1.318.1.1.13.1.5.2.1INTEGERread-onlymandatory
airFMModStatusTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.2.2not-accessiblemandatory
airFMModStatusEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1not-accessiblemandatory
airFMModStatusModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.1INTEGERread-onlymandatory
airFMModSupplyTempC
OBJECT-TYPE
The temperature measured at the supply sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.2INTEGERread-onlymandatory
airFMModSupplyTempF
OBJECT-TYPE
The temperature measured at the supply sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.3INTEGERread-onlymandatory
airFMModSupplyHum
OBJECT-TYPE
The humidity measured at the supply sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.4INTEGERread-onlymandatory
airFMModReturnTempC
OBJECT-TYPE
The temperature measured at the return sensor. Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.5INTEGERread-onlymandatory
airFMModReturnTempF
OBJECT-TYPE
The temperature measured at the return sensor. Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.6INTEGERread-onlymandatory
airFMModReturnHum
OBJECT-TYPE
The humidity measured at the return sensor. Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.7INTEGERread-onlymandatory
airFMModFilterDiffPresPa
OBJECT-TYPE
The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.8INTEGERread-onlymandatory
airFMModFilterDiffPresInWC
OBJECT-TYPE
The difference in pressure on either side of the air filters. A high differential pressure indicates a clogged filter. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.9INTEGERread-onlymandatory
airFMModCoilDiffPresPa
OBJECT-TYPE
The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.10INTEGERread-onlymandatory
airFMModCoilDiffPresInWC
OBJECT-TYPE
The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.11INTEGERread-onlymandatory
airFMModProperties
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.3
airFMModPropTableSize
OBJECT-TYPE
The number of entries in the airFMModPropTable.
1.3.6.1.4.1.318.1.1.13.1.5.3.1INTEGERread-onlymandatory
airFMModPropTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.3.2not-accessiblemandatory
airFMModPropEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1not-accessiblemandatory
airFMModPropModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1INTEGERread-onlymandatory
airFMModOutputCapacity
OBJECT-TYPE
The cooling capacity (in Kilowatts) of the displayed Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.2INTEGER {notApplicable(1), kw45(2), kw35(3), kw40(4), kw50(5), kw80(6)}read-onlymandatory
airFMModCapacityCtrl
OBJECT-TYPE
The method used to load and unload the compressors. Tandem compressor Modules use two stages (one compressor each). Single compressor Modules use hot gas bypass. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.3INTEGER {notApplicable(1), tandem(2), hotGasBypass(3)}read-onlymandatory
airFMModHeaterType
OBJECT-TYPE
The type of reheating device installed in this Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.4INTEGER {notApplicable(1), none(2), electricSCR(3), steam(4), hotWaterOnOff(5), hotGasReheat(6), hotGasAndElectric(7), hotWaterProp(8)}read-onlymandatory
airFMModElectricHeaterType
OBJECT-TYPE
The type/capacity of the electric heater, if installed. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.5INTEGER {notApplicable(1), kw10(2), kw15(3)}read-onlymandatory
airFMModHumidifierType
OBJECT-TYPE
The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.6INTEGER {notApplicable(1), none(2), steamElectrode(3), liveSteam(4)}read-onlymandatory
airFMModBlwrFreqSetting
OBJECT-TYPE
Frequency of the blower in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.7INTEGERread-onlymandatory
airFMModNomCoilDiffPresPa
OBJECT-TYPE
The difference in pressure on either side of the cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.8INTEGERread-onlymandatory
airFMModNomCoilDiffPresInWC
OBJECT-TYPE
The difference in pressure on either side of the cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.9INTEGERread-onlymandatory
airFMModCondPump
OBJECT-TYPE
Indicates the presence of a condensate pump in the Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.10INTEGER {notApplicable(1), notPresent(2), present(3)}read-onlymandatory
airFMModFireDetector
OBJECT-TYPE
Indicates the presence of a fire detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.11INTEGER {notApplicable(1), notPresent(2), present(3)}read-onlymandatory
airFMModSmokeDetector
OBJECT-TYPE
Indicates the presence of a smoke detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.12INTEGER {notApplicable(1), notPresent(2), present(3)}read-onlymandatory
airFMModWaterDetector
OBJECT-TYPE
Indicates the presence of a water leak detector for each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.13INTEGER {notApplicable(1), notPresent(2), present(3)}read-onlymandatory
airFMModCooling
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.4
airFMModCoolTableSize
OBJECT-TYPE
The number of entries in the airFMModCoolTable.
1.3.6.1.4.1.318.1.1.13.1.5.4.1INTEGERread-onlymandatory
airFMModCoolTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.4.2not-accessiblemandatory
airFMModCoolEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1not-accessiblemandatory
airFMModCoolModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.1INTEGERread-onlymandatory
airFMModComp1
OBJECT-TYPE
The status of compressor 1 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.2INTEGER {notApplicable(1), on(2), off(3)}read-onlymandatory
airFMModComp2
OBJECT-TYPE
The status of compressor 2 of the tandem compressor unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.3INTEGER {notApplicable(1), on(2), off(3)}read-onlymandatory
airFMModSuctPresKPa
OBJECT-TYPE
The refrigerant pressure measured at the suction inlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.4INTEGERread-onlymandatory
airFMModSuctPresPSI
OBJECT-TYPE
The refrigerant pressure measured at the suction inlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.5INTEGERread-onlymandatory
airFMModDischPresKPa
OBJECT-TYPE
The refrigerant pressure measured at the discharge outlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.6INTEGERread-onlymandatory
airFMModDischPresPSI
OBJECT-TYPE
The refrigerant pressure measured at the discharge outlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.7INTEGERread-onlymandatory
airFMModCondFluidVlvPos
OBJECT-TYPE
The position of the condenser fluid valve. The valve regulates the flow of liquid coolant into the heat exchanger (condenser). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.8INTEGERread-onlymandatory
airFMModCoilFluidVlvPos
OBJECT-TYPE
The position of the coil fluid valve. The valve regulates the flow of liquid coolant in the fluid cooling coil (MultiCool, Economizer, or Chilled Water). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.9INTEGERread-onlymandatory
airFMModHumidity
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.5
airFMModHumTableSize
OBJECT-TYPE
The number of entries in the airFMModHumTable.
1.3.6.1.4.1.318.1.1.13.1.5.5.1INTEGERread-onlymandatory
airFMModHumTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.5.2not-accessiblemandatory
airFMModHumEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1not-accessiblemandatory
airFMModHumModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.1INTEGERread-onlymandatory
airFMModHumidifier
OBJECT-TYPE
The type of equipment installed in the Module to run the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.2INTEGER {notApplicable(1), none(2), steamElectrode(3), liveSteam(4)}read-onlymandatory
airFMModElectrodeCurrent
OBJECT-TYPE
The current drawn by the electrodes of the steam cylinder humidifier. Measured in tenths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.3INTEGERread-onlymandatory
airFMModHumActualOutput
OBJECT-TYPE
The humidification output of an individual Module. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.4INTEGERread-onlymandatory
airFMModWaterConductivity
OBJECT-TYPE
The conductivity of the water in the humidifier cylinder. Measured in microSiemens per centimeter. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.5INTEGERread-onlymandatory
airFMModHotWaterVlvPos
OBJECT-TYPE
The position of the hot water valve. 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.6INTEGERread-onlymandatory
airFMModStmElectHumMode
OBJECT-TYPE
Set the humidifier function mode. Off: Remove power from electrodes. Auto: Humidifier controlled by Module controller. Drain: Remove power from electrodes and drain the cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.7INTEGER {notApplicable(1), off(2), auto(3), drain(4)}read-writemandatory
airFMModBlower1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.6
airFMModBlwr1TableSize
OBJECT-TYPE
The number of entries in the airFMModBlwr1Table.
1.3.6.1.4.1.318.1.1.13.1.5.6.1INTEGERread-onlymandatory
airFMModBlwr1Table
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.6.2not-accessiblemandatory
airFMModBlwr1Entry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1not-accessiblemandatory
airFMModBlwr1ModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.1INTEGERread-onlymandatory
airFMModBlwr1CtrlType
OBJECT-TYPE
The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.2INTEGER {notApplicable(1), fujiVFD(2), ecController(3), danfossVFD(4)}read-onlymandatory
airFMModBlwr1CmdFreq
OBJECT-TYPE
The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.3INTEGERread-onlymandatory
airFMModBlwr1ActFreq
OBJECT-TYPE
The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.4INTEGERread-onlymandatory
airFMModBlwr1Poles
OBJECT-TYPE
The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.5INTEGERread-onlymandatory
airFMModBlwr1RatedHorsePower
OBJECT-TYPE
The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.6INTEGERread-onlymandatory
airFMModBlwr1RatedCurrent
OBJECT-TYPE
The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.7INTEGERread-onlymandatory
airFMModBlwr1ActTorq
OBJECT-TYPE
The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.8INTEGERread-onlymandatory
airFMModBlwr1Current
OBJECT-TYPE
The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.9INTEGERread-onlymandatory
airFMModBlwr1Vlt
OBJECT-TYPE
The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.10INTEGERread-onlymandatory
airFMModBlwr1DCLinkVlt
OBJECT-TYPE
The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.11INTEGERread-onlymandatory
airFMModBlwr1AccTime
OBJECT-TYPE
The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.12INTEGERread-onlymandatory
airFMModBlwr1DecTime
OBJECT-TYPE
The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.13INTEGERread-onlymandatory
airFMModBlwr1CapLife
OBJECT-TYPE
The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.14INTEGERread-onlymandatory
airFMModBlwr1CtrlCoolFanLife
OBJECT-TYPE
The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.15INTEGERread-onlymandatory
airFMModBlwr1ElOvMode
OBJECT-TYPE
Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.16INTEGER {notApplicable(1), inactive(2), active(3)}read-onlymandatory
airFMModBlwr1ElOvSetting
OBJECT-TYPE
The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.17INTEGERread-onlymandatory
airFMModBlwr1ElOvTimeConst
OBJECT-TYPE
The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.18INTEGERread-onlymandatory
airFMModBlwr1FanPower
OBJECT-TYPE
The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.19INTEGERread-onlymandatory
airFMModBlwr1HeatsinkTempC
OBJECT-TYPE
The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.20INTEGERread-onlymandatory
airFMModBlwr1HeatsinkTempF
OBJECT-TYPE
The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.21INTEGERread-onlymandatory
airFMModBlwr1ChokeTempC
OBJECT-TYPE
The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.22INTEGERread-onlymandatory
airFMModBlwr1ChokeTempF
OBJECT-TYPE
The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.23INTEGERread-onlymandatory
airFMModBlwr1InverterTempC
OBJECT-TYPE
The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.24INTEGERread-onlymandatory
airFMModBlwr1InverterTempF
OBJECT-TYPE
The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.25INTEGERread-onlymandatory
airFMModBlower2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.7
airFMModBlwr2TableSize
OBJECT-TYPE
The number of entries in the airFMModBlwr2Table.
1.3.6.1.4.1.318.1.1.13.1.5.7.1INTEGERread-onlymandatory
airFMModBlwr2Table
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.7.2not-accessiblemandatory
airFMModBlwr2Entry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1not-accessiblemandatory
airFMModBlwr2ModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.1INTEGERread-onlymandatory
airFMModBlwr2CtrlType
OBJECT-TYPE
The type of blower controller. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.2INTEGER {notApplicable(1), fujiVFD(2), ecController(3), danfossVFD(4)}read-onlymandatory
airFMModBlwr2CmdFreq
OBJECT-TYPE
The requested operating frequency for the blower. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.3INTEGERread-onlymandatory
airFMModBlwr2ActFreq
OBJECT-TYPE
The frequency at which the blower controller is operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.4INTEGERread-onlymandatory
airFMModBlwr2Poles
OBJECT-TYPE
The number of poles of the blower motor that the blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.5INTEGERread-onlymandatory
airFMModBlwr2RatedHorsePower
OBJECT-TYPE
The power rating of the blower motor. Measured in hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.6INTEGERread-onlymandatory
airFMModBlwr2RatedCurrent
OBJECT-TYPE
The current rating of the blower motor. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.7INTEGERread-onlymandatory
airFMModBlwr2ActTorq
OBJECT-TYPE
The actual torque of the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.8INTEGERread-onlymandatory
airFMModBlwr2Current
OBJECT-TYPE
The percent of rated current drawn by the blower motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.9INTEGERread-onlymandatory
airFMModBlwr2Vlt
OBJECT-TYPE
The voltage supplied to the blower motor. Measured in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.10INTEGERread-onlymandatory
airFMModBlwr2DCLinkVlt
OBJECT-TYPE
The voltage of the blower controller's DC bus. Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.11INTEGERread-onlymandatory
airFMModBlwr2AccTime
OBJECT-TYPE
The time to accelerate the blower to the specified frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.12INTEGERread-onlymandatory
airFMModBlwr2DecTime
OBJECT-TYPE
The time to decelerate the blower frequency to zero. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.13INTEGERread-onlymandatory
airFMModBlwr2CapLife
OBJECT-TYPE
The remaining life of the main circuit capacitor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.14INTEGERread-onlymandatory
airFMModBlwr2CtrlCoolFanLife
OBJECT-TYPE
The total operation time of the blower controller cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.15INTEGERread-onlymandatory
airFMModBlwr2ElOvMode
OBJECT-TYPE
Enables or disables the electronic overload relay. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.16INTEGER {notApplicable(1), inactive(2), active(3)}read-onlymandatory
airFMModBlwr2ElOvSetting
OBJECT-TYPE
The electronic overload relay is activated when the current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.17INTEGERread-onlymandatory
airFMModBlwr2ElOvTimeConst
OBJECT-TYPE
The delay between the current exceeding the overload threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.18INTEGERread-onlymandatory
airFMModBlwr2FanPower
OBJECT-TYPE
The actual power of the blower motor. Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.19INTEGERread-onlymandatory
airFMModBlwr2HeatsinkTempC
OBJECT-TYPE
The temperature of the heatsink on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.20INTEGERread-onlymandatory
airFMModBlwr2HeatsinkTempF
OBJECT-TYPE
The temperature of the heatsink on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.21INTEGERread-onlymandatory
airFMModBlwr2ChokeTempC
OBJECT-TYPE
The temperature of the choke on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.22INTEGERread-onlymandatory
airFMModBlwr2ChokeTempF
OBJECT-TYPE
The temperature of the choke on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.23INTEGERread-onlymandatory
airFMModBlwr2InverterTempC
OBJECT-TYPE
The temperature of the inverter on the blower controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.24INTEGERread-onlymandatory
airFMModBlwr2InverterTempF
OBJECT-TYPE
The temperature of the inverter on the blower controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.25INTEGERread-onlymandatory
airFMModRunHours
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.8
airFMModRHTableSize
OBJECT-TYPE
The number of entries in the airFMModRHTable.
1.3.6.1.4.1.318.1.1.13.1.5.8.1INTEGERread-onlymandatory
airFMModRHTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.8.2not-accessiblemandatory
airFMModRHEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1not-accessiblemandatory
airFMModRHModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.1INTEGERread-onlymandatory
airFMModRHComp1
OBJECT-TYPE
Compressor 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.2INTEGERread-onlymandatory
airFMModRHComp2
OBJECT-TYPE
Compressor 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.3INTEGERread-onlymandatory
airFMModRHHeater
OBJECT-TYPE
Heater run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.4INTEGERread-onlymandatory
airFMModRHHum
OBJECT-TYPE
Humidifier run hours A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.5INTEGERread-onlymandatory
airFMModRHBlwr1
OBJECT-TYPE
Blower 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.6INTEGERread-onlymandatory
airFMModRHBlwr2
OBJECT-TYPE
Blower 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.7INTEGERread-onlymandatory
airFMModRHBlwrCtrl1
OBJECT-TYPE
Blower Controller 1 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.8INTEGERread-onlymandatory
airFMModRHBlwrCtrl2
OBJECT-TYPE
Blower Controller 2 run hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.9INTEGERread-onlymandatory
airFMModRHComp1Reset
OBJECT-TYPE
Reset the compressor 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.10INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModRHComp2Reset
OBJECT-TYPE
Reset the compressor 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.11INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModRHHeaterReset
OBJECT-TYPE
Reset the heater run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.12INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModRHHumReset
OBJECT-TYPE
Reset the humidifier run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.13INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModRHBlwr1Reset
OBJECT-TYPE
Reset the blower 1 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.14INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModRHBlwr2Reset
OBJECT-TYPE
Reset the blower 2 run hours. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.15INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntervals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.9
airFMModServIntComp1
OBJECT-TYPE
The interval at which to generate a maintenance alarm for compressor 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.1INTEGERread-writemandatory
airFMModServIntComp2
OBJECT-TYPE
The interval at which to generate a maintenance alarm for compressor 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.2INTEGERread-writemandatory
airFMModServIntHeater
OBJECT-TYPE
The interval at which to generate a maintenance alarm for the reheat components. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.3INTEGERread-writemandatory
airFMModServIntHum
OBJECT-TYPE
The interval at which to generate a maintenance alarm for the humidifier. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.4INTEGERread-writemandatory
airFMModServIntBlwr1
OBJECT-TYPE
The interval at which to generate a maintenance alarm for blower 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.5INTEGERread-writemandatory
airFMModServIntBlwr2
OBJECT-TYPE
The interval at which to generate a maintenance alarm for blower 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.6INTEGERread-writemandatory
airFMModServIntBlwrCtrl1
OBJECT-TYPE
The interval at which to generate a maintenance alarm for blower controller 1. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.7INTEGERread-writemandatory
airFMModServIntBlwrCtrl2
OBJECT-TYPE
The interval at which to generate a maintenance alarm for blower controller 2. Values stored in increments of 100 hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.9.8INTEGERread-writemandatory
airFMModServIntResets
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.5.10
airFMModServIntResetTableSize
OBJECT-TYPE
The number of entries in the airFMModServIntTable.
1.3.6.1.4.1.318.1.1.13.1.5.10.1INTEGERread-onlymandatory
airFMModServIntResetTable
OBJECT-TYPE
Allows for getting information from each module in the system.
1.3.6.1.4.1.318.1.1.13.1.5.10.2not-accessiblemandatory
airFMModServIntResetEntry
OBJECT-TYPE
The module to get information from.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1not-accessiblemandatory
airFMModServIntResetModuleIndex
OBJECT-TYPE
The index of the module.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1INTEGERread-onlymandatory
airFMModServIntComp1Reset
OBJECT-TYPE
Reset the compressor 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.2INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntComp2Reset
OBJECT-TYPE
Reset the compressor 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.3INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntHeaterReset
OBJECT-TYPE
Reset the heater service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.4INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntHumReset
OBJECT-TYPE
Reset the humidifier service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.5INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntBlwr1Reset
OBJECT-TYPE
Reset the blower 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.6INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntBlwr2Reset
OBJECT-TYPE
Reset the blower 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.7INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntBlwrCtrl1Reset
OBJECT-TYPE
Reset the blower controller 1 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.8INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMModServIntBlwrCtrl2Reset
OBJECT-TYPE
Reset the blower controller 2 service interval maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.9INTEGER {notApplicable(1), noOperation(2), reset(3)}read-writemandatory
airFMAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.1.6
airFMAlarmClearActiveGroupAlarms
OBJECT-TYPE
Clear active group alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and return the noOperation value.
1.3.6.1.4.1.318.1.1.13.1.6.1INTEGER {noOperation(1), clearAlarms(2)}read-writemandatory
airFMAlarmClearActiveSysModAlarms
OBJECT-TYPE
Clear active system and module alarms. If alarm conditions are still present, new alarms will be generated for those conditions. Getting this OID will do nothing and return the noOperation value.
1.3.6.1.4.1.318.1.1.13.1.6.2INTEGER {noOperation(1), clearAlarms(2)}read-writemandatory
airFMAlarmConditionsTableSize
OBJECT-TYPE
The number of active alarm conditions in the airFMAlarmConditionTable.
1.3.6.1.4.1.318.1.1.13.1.6.3INTEGERread-onlymandatory
airFMAlarmConditionsTable
OBJECT-TYPE
Table of active alarm conditions for the device.
1.3.6.1.4.1.318.1.1.13.1.6.4not-accessiblemandatory
airFMAlarmConditionsEntry
OBJECT-TYPE
Alarm condition specification
1.3.6.1.4.1.318.1.1.13.1.6.4.1not-accessiblemandatory
airFMAlarmConditionsIndex
OBJECT-TYPE
Alarm condition index.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.1INTEGERread-onlymandatory
airFMAlarmSeverity
OBJECT-TYPE
Severity of the alarm.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.2INTEGER {informational(1), warningMinor(2), criticalMajor(3)}read-onlymandatory
airFMAlarmType
OBJECT-TYPE
Type of alarm.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.3INTEGER {group(1), system(2), mainMod(3), expMod1(4), expMod2(5)}read-onlymandatory
airFMEventCode
OBJECT-TYPE
APC event code for the alarm.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.4INTEGERread-onlymandatory
airFMAlarmDate
OBJECT-TYPE
Date the alarm was recorded.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.5DisplayStringread-onlymandatory
airFMAlarmTime
OBJECT-TYPE
Time the alarm was recorded.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.6DisplayStringread-onlymandatory
airFMAlarmDescription
OBJECT-TYPE
Description of the alarm.
1.3.6.1.4.1.318.1.1.13.1.6.4.1.7DisplayString (SIZE(0..64))read-onlymandatory
airPA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.2
airPAIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.2.1
airPAIdentName
OBJECT-TYPE
A character string identifying the device name.
1.3.6.1.4.1.318.1.1.13.2.1.1DisplayStringread-onlymandatory
airPAModelNumber
OBJECT-TYPE
A character string identifying the device model number.
1.3.6.1.4.1.318.1.1.13.2.1.2DisplayStringread-onlymandatory
airPADateOfManufacture
OBJECT-TYPE
A character string identifying when the device was produced.
1.3.6.1.4.1.318.1.1.13.2.1.3DisplayStringread-onlymandatory
airPASerialNumber
OBJECT-TYPE
A character string identifying the device serial number.
1.3.6.1.4.1.318.1.1.13.2.1.4DisplayStringread-onlymandatory
airPAFirmwareRevision
OBJECT-TYPE
A character string identifying the device firmware revision.
1.3.6.1.4.1.318.1.1.13.2.1.5DisplayStringread-onlymandatory
airPAHardwareRevision
OBJECT-TYPE
A character string identifying the device hardware revision.
1.3.6.1.4.1.318.1.1.13.2.1.6DisplayStringread-onlymandatory
airPAStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.2.2
airPASystemPower
OBJECT-TYPE
The status of the unit's system power setting. ON(1) The system power is turned on. OFF(2) The system power is turned off.
1.3.6.1.4.1.318.1.1.13.2.2.1INTEGER {powerON(1), powerOFF(2)}read-onlymandatory
airPAOperatingMode
OBJECT-TYPE
The current operating mode of the unit. OFF(1) The system is off. VENTING(2) The system's venting function is active. COOLING(3) The system's cooling function is active.
1.3.6.1.4.1.318.1.1.13.2.2.2INTEGER {modeOFF(1), modeVENTING(2), modeCOOLING(3)}read-onlymandatory
airPASetpointTempF
OBJECT-TYPE
The temperature setpoint in Fahrenheit to which the unit is controlling.
1.3.6.1.4.1.318.1.1.13.2.2.3INTEGERread-onlymandatory
airPASetpointTempC
OBJECT-TYPE
The temperature setpoint in Celsius to which the unity is controlling.
1.3.6.1.4.1.318.1.1.13.2.2.4INTEGERread-onlymandatory
airPABlowerSpeed
OBJECT-TYPE
The unit's blower speed setting. LOW(1) The blower speed is low. HIGH(2) The blower speed is high.
1.3.6.1.4.1.318.1.1.13.2.2.5INTEGER {speedLOW(1), speedHIGH(2)}read-onlymandatory
airPACompressor
OBJECT-TYPE
The unit's compressor status. ON(1) The compressor is turned on. OFF(2) The compressor is turned off.
1.3.6.1.4.1.318.1.1.13.2.2.6INTEGER {statusON(1), statusOFF(2)}read-onlymandatory
airPACondenserFan
OBJECT-TYPE
The unit's condenser fan status. ON(1) The condenser fan is turned on. OFF(2) The condenser fan is turned off.
1.3.6.1.4.1.318.1.1.13.2.2.7INTEGER {statusON(1), statusOFF(2)}read-onlymandatory
airPACondensatePump
OBJECT-TYPE
The unit's condensate pump status. ON(1) The condensate pump is turned on. OFF(2) The condensate pump is turned off.
1.3.6.1.4.1.318.1.1.13.2.2.8INTEGER {statusON(1), statusOFF(2)}read-onlymandatory
airPASupplyTempF
OBJECT-TYPE
The supply temperature in degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.2.2.9INTEGERread-onlymandatory
airPASupplyTempC
OBJECT-TYPE
The supply temperature in degrees Celsius.
1.3.6.1.4.1.318.1.1.13.2.2.10INTEGERread-onlymandatory
airPAReturnTempF
OBJECT-TYPE
The return temperature in degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.2.2.11INTEGERread-onlymandatory
airPAReturnTempC
OBJECT-TYPE
The return temperature in degrees Celsius.
1.3.6.1.4.1.318.1.1.13.2.2.12INTEGERread-onlymandatory
airPARemoteTempF
OBJECT-TYPE
The remote temperature in degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.2.2.13INTEGERread-onlymandatory
airPARemoteTempC
OBJECT-TYPE
The remote temperature in degrees Celsius.
1.3.6.1.4.1.318.1.1.13.2.2.14INTEGERread-onlymandatory
airPARemoteHumidity
OBJECT-TYPE
The remote humidity.
1.3.6.1.4.1.318.1.1.13.2.2.15INTEGERread-onlymandatory
airIR
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3
airIRAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.1
airIRAlarmConditionsTableSize
OBJECT-TYPE
The number of active alarm conditions in the airIRAlarmConditionTable.
1.3.6.1.4.1.318.1.1.13.3.1.1INTEGERread-onlymandatory
airIRAlarmConditionsTable
OBJECT-TYPE
Table of active alarm conditions for the device.
1.3.6.1.4.1.318.1.1.13.3.1.2not-accessiblemandatory
airIRAlarmConditionsEntry
OBJECT-TYPE
Alarm condition specification
1.3.6.1.4.1.318.1.1.13.3.1.2.1not-accessiblemandatory
airIRAlarmConditionsIndex
OBJECT-TYPE
Alarm condition index.
1.3.6.1.4.1.318.1.1.13.3.1.2.1.1INTEGERread-onlymandatory
airIREventCode
OBJECT-TYPE
Code for the alarm.
1.3.6.1.4.1.318.1.1.13.3.1.2.1.2INTEGERread-onlymandatory
airIRAlarmDescription
OBJECT-TYPE
Description of the alarm.
1.3.6.1.4.1.318.1.1.13.3.1.2.1.3DisplayString (SIZE(0..64))read-onlymandatory
airIRRC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2
airIRRCGroup
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.1
airIRRCGroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.1.1
airIRRCGroupStatusCoolOutput
OBJECT-TYPE
Group coolant output in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.1INTEGERread-onlymandatory
airIRRCGroupStatusCoolDemand
OBJECT-TYPE
Group coolant demand in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.2INTEGERread-onlymandatory
airIRRCGroupStatusAirFlowUS
OBJECT-TYPE
Group air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.3INTEGERread-onlymandatory
airIRRCGroupStatusAirFlowMetric
OBJECT-TYPE
Group air flow in liters per second.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.4INTEGERread-onlymandatory
airIRRCGroupStatusMaxRackInletTempUS
OBJECT-TYPE
Group maximum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.5INTEGERread-onlymandatory
airIRRCGroupStatusMaxRackInletTempMetric
OBJECT-TYPE
Group maximum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.6INTEGERread-onlymandatory
airIRRCGroupStatusMinRackInletTempUS
OBJECT-TYPE
Group minimum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.7INTEGERread-onlymandatory
airIRRCGroupStatusMinRackInletTempMetric
OBJECT-TYPE
Group minimum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.8INTEGERread-onlymandatory
airIRRCGroupStatusActiveFlowControlStatus
OBJECT-TYPE
Status of the active flow control system.
1.3.6.1.4.1.318.1.1.13.3.2.1.1.9INTEGER {under(1), okay(2), over(3), notApplicable(4)}read-onlymandatory
airIRRCGroupSetpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.1.2
airIRRCGroupSetpointsCoolUS
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.1INTEGERread-writemandatory
airIRRCGroupSetpointsCoolMetric
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.2INTEGERread-writemandatory
airIRRCGroupSetpointsSupplyAirUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.3INTEGERread-writemandatory
airIRRCGroupSetpointsSupplyAirMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.4INTEGERread-writemandatory
airIRRCGroupSetpointsFanSpeedPreference
OBJECT-TYPE
The preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.5INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)}read-writemandatory
airIRRCGroupSetpointsFanSpeedControl
OBJECT-TYPE
The fan speed control setting. Automatic(1) - controller manages fan speed. Manual(2) - fan speed is fixed and set by the fan speed preference. See airIRRCGroupSetpointsFanSpeedPreference.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.6INTEGER {automatic(1), manual(2)}read-writemandatory
airIRRCGroupSetpointsActiveFlowControlBias
OBJECT-TYPE
The active flow control bias setting.
1.3.6.1.4.1.318.1.1.13.3.2.1.2.7INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)}read-writemandatory
airIRRCGroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.1.3
airIRRCGroupConfigNumberofCoolingUnits
OBJECT-TYPE
The number of cooling units present in the group.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.1INTEGERread-writemandatory
airIRRCGroupConfigConfigurationType
OBJECT-TYPE
The group configuration type.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.2INTEGER {racs(1), hacs(2), in-row(3), cacs(4)}read-writemandatory
airIRRCGroupConfigPctGlycol
OBJECT-TYPE
The glycol mixture in percent.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.3INTEGERread-writemandatory
airIRRCGroupConfigCoolGainP
OBJECT-TYPE
The gain component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.4INTEGERread-writemandatory
airIRRCGroupConfigCoolResetRateI
OBJECT-TYPE
The integral component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.5INTEGERread-writemandatory
airIRRCGroupConfigCoolDerivativeD
OBJECT-TYPE
The derivative component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.6INTEGERread-writemandatory
airIRRCGroupConfigMaxFanSpeed
OBJECT-TYPE
The maximum desired fan speed setting in percent.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.7INTEGERread-writemandatory
airIRRCGroupConfigNumberOfActiveFlowControllers
OBJECT-TYPE
The number of active flow controllers present in the group.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.8INTEGERread-writemandatory
airIRRCGroupConfigActiveFlowControllerLampTest
OBJECT-TYPE
Turns off/on the active flow controller lamp test.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.9INTEGER {off(1), on(2)}read-writemandatory
airIRRCGroupConfigAltitudeUS
OBJECT-TYPE
The group altitude of the units above sea level in feet.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.10INTEGERread-writemandatory
airIRRCGroupConfigAltitudeMetric
OBJECT-TYPE
The group altitude of the units above sea level in meters.
1.3.6.1.4.1.318.1.1.13.3.2.1.3.11INTEGERread-writemandatory
airIRRCUnit
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2
airIRRCUnitIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2.1
airIRRCUnitIdentID
OBJECT-TYPE
The unit identification number.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.1INTEGERread-writemandatory
airIRRCUnitIdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.2DisplayStringread-writemandatory
airIRRCUnitIdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.3DisplayStringread-writemandatory
airIRRCUnitIdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.4DisplayStringread-onlymandatory
airIRRCUnitIdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.5DisplayStringread-onlymandatory
airIRRCUnitIdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.6DisplayStringread-onlymandatory
airIRRCUnitIdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.7DisplayStringread-onlymandatory
airIRRCUnitIdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.3.2.2.1.8DisplayStringread-onlymandatory
airIRRCUnitStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2.2
airIRRCUnitStatusOperateMode
OBJECT-TYPE
The cooling unit operating mode.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.1INTEGER {standby(1), on(2), idle(3)}read-onlymandatory
airIRRCUnitStatusCoolOutput
OBJECT-TYPE
The unit cooling output in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.2INTEGERread-onlymandatory
airIRRCUnitStatusCoolDemand
OBJECT-TYPE
The unit cooling demand in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.3INTEGERread-onlymandatory
airIRRCUnitStatusAirFlowUS
OBJECT-TYPE
The unit air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.4INTEGERread-onlymandatory
airIRRCUnitStatusAirFlowMetric
OBJECT-TYPE
The unit air flow in hundredths of liters per second.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.5INTEGERread-onlymandatory
airIRRCUnitStatusRackInletTempUS
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.6INTEGERread-onlymandatory
airIRRCUnitStatusRackInletTempMetric
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.7INTEGERread-onlymandatory
airIRRCUnitStatusSupplyAirTempUS
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.8INTEGERread-onlymandatory
airIRRCUnitStatusSupplyAirTempMetric
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.9INTEGERread-onlymandatory
airIRRCUnitStatusReturnAirTempUS
OBJECT-TYPE
The unit return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.10INTEGERread-onlymandatory
airIRRCUnitStatusReturnAirTempMetric
OBJECT-TYPE
The unit return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.11INTEGERread-onlymandatory
airIRRCUnitStatusContainmtDPUS
OBJECT-TYPE
The unit containment differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.12INTEGERread-onlymandatory
airIRRCUnitStatusContainmtDPMetric
OBJECT-TYPE
The unit containment differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.13INTEGERread-onlymandatory
airIRRCUnitStatusFilterDPUS
OBJECT-TYPE
The unit air filter differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.14INTEGERread-onlymandatory
airIRRCUnitStatusFilterDPMetric
OBJECT-TYPE
The unit air filter differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.15INTEGERread-onlymandatory
airIRRCUnitStatusFanSpeed
OBJECT-TYPE
The unit average fan speed in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.16INTEGERread-onlymandatory
airIRRCUnitStatusInputState
OBJECT-TYPE
The state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.17INTEGER {open(1), closed(2)}read-onlymandatory
airIRRCUnitStatusOutputState
OBJECT-TYPE
The state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.18INTEGER {open(1), closed(2)}read-onlymandatory
airIRRCUnitStatusActivePowerSource
OBJECT-TYPE
The power source that is powering the unit.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.19INTEGER {sourceA(1), sourceB(2)}read-onlymandatory
airIRRCUnitStatusFluidValvePosition
OBJECT-TYPE
The fluid valve position in percent open.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.20INTEGERread-onlymandatory
airIRRCUnitStatusFluidFlowUS
OBJECT-TYPE
The fluid flow in tenths of gallons per minute.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.21INTEGERread-onlymandatory
airIRRCUnitStatusFluidFlowMetric
OBJECT-TYPE
The fluid flow in hundredths of liters per second.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.22INTEGERread-onlymandatory
airIRRCUnitStatusEnteringFluidTemperatureUS
OBJECT-TYPE
The temperature of the entering fluid in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.23INTEGERread-onlymandatory
airIRRCUnitStatusEnteringFluidTemperatureMetric
OBJECT-TYPE
The temperature of the entering fluid in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.24INTEGERread-onlymandatory
airIRRCUnitStatusLeavingFluidTemperatureUS
OBJECT-TYPE
The temperature of the Leaving fluid in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.25INTEGERread-onlymandatory
airIRRCUnitStatusLeavingFluidTemperatureMetric
OBJECT-TYPE
The temperature of the Leaving fluid in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.26INTEGERread-onlymandatory
airIRRCUnitStatusLeakSensor
OBJECT-TYPE
The state (no-leak/leak) of the leak sensor.
1.3.6.1.4.1.318.1.1.13.3.2.2.2.27INTEGER {no-leak(1), leak(2)}read-onlymandatory
airIRRCUnitRunHours
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2.3
airIRRCUnitRunHoursAirFilter
OBJECT-TYPE
Unit air filter run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.1INTEGERread-onlymandatory
airIRRCUnitRunHoursFan1
OBJECT-TYPE
Unit fan 1 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.2INTEGERread-onlymandatory
airIRRCUnitRunHoursFan2
OBJECT-TYPE
Unit fan 2 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.3INTEGERread-onlymandatory
airIRRCUnitRunHoursFan3
OBJECT-TYPE
Unit fan 3 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.4INTEGERread-onlymandatory
airIRRCUnitRunHoursFan4
OBJECT-TYPE
Unit fan 4 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.5INTEGERread-onlymandatory
airIRRCUnitRunHoursFan5
OBJECT-TYPE
Unit fan 5 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.6INTEGERread-onlymandatory
airIRRCUnitRunHoursFan6
OBJECT-TYPE
Unit fan 6 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.7INTEGERread-onlymandatory
airIRRCUnitRunHoursFan7
OBJECT-TYPE
Unit fan 7 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.8INTEGERread-onlymandatory
airIRRCUnitRunHoursFan8
OBJECT-TYPE
Unit fan 8 run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.9INTEGERread-onlymandatory
airIRRCUnitRunHoursFanPowerSupplyLeft
OBJECT-TYPE
Unit fan left power supply run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.10INTEGERread-onlymandatory
airIRRCUnitRunHoursFanPowerSupplyRight
OBJECT-TYPE
Unit fan right power supply run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.11INTEGERread-onlymandatory
airIRRCUnitRunHoursCondensatePump
OBJECT-TYPE
Unit condensate pump run hours.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.12INTEGERread-onlymandatory
airIRRCUnitRunHoursFanPowerSupplyFeedALeft
OBJECT-TYPE
Unit fan, DC power feed A, left power supply run hours. This is only valid for a DC input unit.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.13INTEGERread-onlymandatory
airIRRCUnitRunHoursFanPowerSupplyFeedARight
OBJECT-TYPE
Unit fan, DC power feed A, right power supply run hours. This is only valid for a DC input unit.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.14INTEGERread-onlymandatory
airIRRCUnitRunHoursFanPowerSupplyFeedBLeft
OBJECT-TYPE
Unit fan, DC power feed B, left power supply run hours. This is only valid for a DC input unit.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.15INTEGERread-onlymandatory
airIRRCUnitRunHoursFanPowerSupplyFeedBRight
OBJECT-TYPE
Unit fan, DC power feed B, right power supply run hours. This is only valid for a DC input unit.
1.3.6.1.4.1.318.1.1.13.3.2.2.3.16INTEGERread-onlymandatory
airIRRCUnitServiceIntervals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2.4
airIRRCUnitServiceIntervalsAirFilter
OBJECT-TYPE
Air filter service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.2.2.4.1INTEGERread-writemandatory
airIRRCUnitServiceIntervalsAirFilterAlarm
OBJECT-TYPE
The air filter service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.2.2.4.2INTEGER {enable(1), disable(2)}read-writemandatory
airIRRCUnitThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2.5
airIRRCUnitThresholdsRackInletHighTempUS
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.1INTEGERread-writemandatory
airIRRCUnitThresholdsRackInletHighTempMetric
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.2INTEGERread-writemandatory
airIRRCUnitThresholdsSupplyAirHighTempUS
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.3INTEGERread-writemandatory
airIRRCUnitThresholdsSupplyAirHighTempMetric
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.4INTEGERread-writemandatory
airIRRCUnitThresholdsReturnAirHighTempUS
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.5INTEGERread-writemandatory
airIRRCUnitThresholdsReturnAirHighTempMetric
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.6INTEGERread-writemandatory
airIRRCUnitThresholdsEnteringFluidHighTempUS
OBJECT-TYPE
Unit entering fluid high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.7INTEGERread-writemandatory
airIRRCUnitThresholdsEnteringFluidHighTempMetric
OBJECT-TYPE
Unit incoming fluid high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.2.2.5.8INTEGERread-writemandatory
airIRRCUnitConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.2.2.6
airIRRCUnitConfigCoolCapacity
OBJECT-TYPE
The cooling capacity options setting.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.1INTEGER {automatic(1), maximum(2)}read-writemandatory
airIRRCUnitConfigStartupDelay
OBJECT-TYPE
The startup delay in seconds.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.2INTEGERread-writemandatory
airIRRCUnitConfigIdleOnLeakDetect
OBJECT-TYPE
The idle on leak options setting.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.3INTEGER {yes(1), no(2)}read-writemandatory
airIRRCUnitConfigPowerSource
OBJECT-TYPE
The configured power source of the unit.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.4INTEGER {sourceA(1), sourceB(2), sourceAandB(3)}read-writemandatory
airIRRCUnitConfigInputNormalState
OBJECT-TYPE
The normal state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.5INTEGER {open(1), closed(2)}read-writemandatory
airIRRCUnitConfigOutputNormalState
OBJECT-TYPE
The normal state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.6INTEGER {open(1), closed(2)}read-writemandatory
airIRRCUnitConfigOutputSource
OBJECT-TYPE
The source of output relay change.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.7INTEGER {anyAlarm(1), criticalAlarm(2)}read-writemandatory
airIRRCUnitConfigIdleOnCoolFail
OBJECT-TYPE
The idle on cool fail options setting. If yes, the system will go into idle mode when a cooling failure is detected. If no, the system will not go into idle mode when a cooling failure is detected.
1.3.6.1.4.1.318.1.1.13.3.2.2.6.8INTEGER {yes(1), no(2)}read-writemandatory
airIRRP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3
airIRRP100
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1
airIRRP100Group
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.1
airIRRP100GroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1
airIRRP100GroupStatusAirFlowUS
OBJECT-TYPE
Group air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.1INTEGERread-onlymandatory
airIRRP100GroupStatusAirFlowMetric
OBJECT-TYPE
Group air flow in liters per second.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.2INTEGERread-onlymandatory
airIRRP100GroupStatusMaxRackInletTempUS
OBJECT-TYPE
Group maximum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.3INTEGERread-onlymandatory
airIRRP100GroupStatusMaxRackInletTempMetric
OBJECT-TYPE
Group maximum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.4INTEGERread-onlymandatory
airIRRP100GroupStatusMinRackInletTempUS
OBJECT-TYPE
Group minimum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.5INTEGERread-onlymandatory
airIRRP100GroupStatusMinRackInletTempMetric
OBJECT-TYPE
Group minimum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.6INTEGERread-onlymandatory
airIRRP100GroupStatusCoolDemand
OBJECT-TYPE
Group coolant demand in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.7INTEGERread-onlymandatory
airIRRP100GroupStatusCoolOutput
OBJECT-TYPE
Group coolant output in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.8INTEGERread-onlymandatory
airIRRP100GroupStatusHumidifyDemand
OBJECT-TYPE
The amount of humidification the group is demanding from the humidifiers in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.9INTEGERread-onlymandatory
airIRRP100GroupStatusHumidifyOutput
OBJECT-TYPE
The actual amount of humidification the group is supplying in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.10INTEGERread-onlymandatory
airIRRP100GroupStatusDehumidifyDemand
OBJECT-TYPE
The amount of dehumidification the group is demanding from the electric heaters in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.11INTEGERread-onlymandatory
airIRRP100GroupStatusDehumidifyOutput
OBJECT-TYPE
The actual amount of dehumidification the group is supplying in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.12INTEGERread-onlymandatory
airIRRP100GroupStatusReheatDemand
OBJECT-TYPE
The amount of heating the group is demanding from the electric heaters in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.13INTEGERread-onlymandatory
airIRRP100GroupStatusReheatOutput
OBJECT-TYPE
The actual amount of heating the group is supplying in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.14INTEGERread-onlymandatory
airIRRP100GroupStatusActiveFlowControlStatus
OBJECT-TYPE
Status of the active flow control system.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.15INTEGER {under(1), okay(2), over(3), notApplicable(4)}read-onlymandatory
airIRRP100GroupStatusDewPointTempUS
OBJECT-TYPE
Group average dew point temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.16INTEGERread-onlymandatory
airIRRP100GroupStatusDewPointTempMetric
OBJECT-TYPE
Group average dew point temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.1.17INTEGERread-onlymandatory
airIRRP100GroupSetpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2
airIRRP100GroupSetpointsCoolUS
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.1INTEGERread-writemandatory
airIRRP100GroupSetpointsCoolMetric
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.2INTEGERread-writemandatory
airIRRP100GroupSetpointsSupplyAirUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.3INTEGERread-writemandatory
airIRRP100GroupSetpointsSupplyAirMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.4INTEGERread-writemandatory
airIRRP100GroupSetpointsHumidify
OBJECT-TYPE
Group humidify setpoint in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.5INTEGERread-writemandatory
airIRRP100GroupSetpointsDehumidify
OBJECT-TYPE
Group dehumidify setpoint in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.6INTEGERread-writemandatory
airIRRP100GroupSetpointsDehumidifyDeadband
OBJECT-TYPE
Group dehumidify deadband in percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.7INTEGERread-writemandatory
airIRRP100GroupSetpointsReheatUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.8INTEGERread-writemandatory
airIRRP100GroupSetpointsReheatMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.9INTEGERread-writemandatory
airIRRP100GroupSetpointsFanSpeedPreference
OBJECT-TYPE
The preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.10INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)}read-writemandatory
airIRRP100GroupSetpointsFanSpeedControl
OBJECT-TYPE
The fan speed control setting.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.11INTEGER {automatic(1), manual(2)}read-writemandatory
airIRRP100GroupSetpointsActiveFlowControlBias
OBJECT-TYPE
The active flow control bias setting.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.2.12INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)}read-writemandatory
airIRRP100GroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3
airIRRP100GroupConfigNumberofCoolingUnits
OBJECT-TYPE
The number of cooling units present in the group.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.1INTEGERread-writemandatory
airIRRP100GroupConfigConfigurationType
OBJECT-TYPE
The group configuration type.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.2INTEGER {racs(1), hacs(2), in-row(3), cacs(4)}read-writemandatory
airIRRP100GroupConfigCoolGainP
OBJECT-TYPE
The gain component of the cool PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.3INTEGERread-writemandatory
airIRRP100GroupConfigCoolResetRateI
OBJECT-TYPE
The integral component of the cool PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.4INTEGERread-writemandatory
airIRRP100GroupConfigCoolDerivativeD
OBJECT-TYPE
The derivative component of the cool PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.5INTEGERread-writemandatory
airIRRP100GroupConfigHumidifySensitivityBand
OBJECT-TYPE
The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.6INTEGERread-writemandatory
airIRRP100GroupConfigReheatGainP
OBJECT-TYPE
The gain component of the reheat PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.7INTEGERread-writemandatory
airIRRP100GroupConfigReheatResetRateI
OBJECT-TYPE
The integral component of the reheat PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.8INTEGERread-writemandatory
airIRRP100GroupConfigReheatDerivativeD
OBJECT-TYPE
The derivative component of the reheat PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.9INTEGERread-writemandatory
airIRRP100GroupConfigNumberofBackupUnits
OBJECT-TYPE
The number of backup units.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.10INTEGERread-writemandatory
airIRRP100GroupConfigRuntimeBalancingEnable
OBJECT-TYPE
Enable or disable runtime balancing feature.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.11INTEGER {disable(1), enable(2)}read-writemandatory
airIRRP100GroupConfigLoadAssistEnable
OBJECT-TYPE
Enable or disable load assist feature.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.12INTEGER {disable(1), enable(2)}read-writemandatory
airIRRP100GroupConfigFullRPBackups
OBJECT-TYPE
The number of full featured RPs that can be used as backup units.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.13INTEGERread-writemandatory
airIRRP100GroupConfigMaxFanSpeed
OBJECT-TYPE
The maximum desired fan speed setting in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.14INTEGERread-writemandatory
airIRRP100GroupConfigNumberOfActiveFlowControllers
OBJECT-TYPE
The number of active flow controllers present in the group.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.15INTEGERread-writemandatory
airIRRP100GroupConfigActiveFlowControllerLampTest
OBJECT-TYPE
Turns off/on the active flow controller lamp test.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.16INTEGER {off(1), on(2)}read-writemandatory
airIRRP100GroupConfigAltitudeUS
OBJECT-TYPE
The group altitude of the units above sea level in feet.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.17INTEGERread-writemandatory
airIRRP100GroupConfigAltitudeMetric
OBJECT-TYPE
The group altitude of the units above sea level in meters.
1.3.6.1.4.1.318.1.1.13.3.3.1.1.3.18INTEGERread-writemandatory
airIRRP100Unit
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2
airIRRP100UnitIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1
airIRRP100UnitIdentID
OBJECT-TYPE
The unit identification number.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.1INTEGERread-writemandatory
airIRRP100UnitIdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.2DisplayStringread-writemandatory
airIRRP100UnitIdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.3DisplayStringread-writemandatory
airIRRP100UnitIdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.4DisplayStringread-onlymandatory
airIRRP100UnitIdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.5DisplayStringread-onlymandatory
airIRRP100UnitIdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.6DisplayStringread-onlymandatory
airIRRP100UnitIdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.7DisplayStringread-onlymandatory
airIRRP100UnitIdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.1.8DisplayStringread-onlymandatory
airIRRP100UnitStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2
airIRRP100UnitStatusOperateMode
OBJECT-TYPE
The cooling unit operating mode.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.1INTEGER {standby(1), on(2), idle(3), prestart(4), service(5), backup(6), assist(7)}read-onlymandatory
airIRRP100UnitStatusRackInletTempUS
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.2INTEGERread-onlymandatory
airIRRP100UnitStatusRackInletTempMetric
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.3INTEGERread-onlymandatory
airIRRP100UnitStatusSupplyAirTempUS
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.4INTEGERread-onlymandatory
airIRRP100UnitStatusSupplyAirTempMetric
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.5INTEGERread-onlymandatory
airIRRP100UnitStatusReturnAirTempUS
OBJECT-TYPE
The unit return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.6INTEGERread-onlymandatory
airIRRP100UnitStatusReturnAirTempMetric
OBJECT-TYPE
The unit return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.7INTEGERread-onlymandatory
airIRRP100UnitStatusSupplyHumidity
OBJECT-TYPE
The relative humidity of the supply air in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8INTEGERread-onlymandatory
airIRRP100UnitStatusReturnHumidity
OBJECT-TYPE
The relative humidity of the return air in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.9INTEGERread-onlymandatory
airIRRP100UnitStatusAirFlowUS
OBJECT-TYPE
The unit air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.10INTEGERread-onlymandatory
airIRRP100UnitStatusAirFlowMetric
OBJECT-TYPE
The unit air flow in hundredths of liters per second.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.11INTEGERread-onlymandatory
airIRRP100UnitStatusFanSpeed
OBJECT-TYPE
The unit average fan speed in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.12INTEGERread-onlymandatory
airIRRP100UnitStatusCoolDemand
OBJECT-TYPE
The unit cooling demand in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.13INTEGERread-onlymandatory
airIRRP100UnitStatusCoolOutput
OBJECT-TYPE
The unit cooling output in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.14INTEGERread-onlymandatory
airIRRP100UnitStatusHumidifyDemand
OBJECT-TYPE
The amount of humidification the unit is demanding from the humidifier in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.15INTEGERread-onlymandatory
airIRRP100UnitStatusHumidifyOutput
OBJECT-TYPE
The actual humidification output of the unit in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.16INTEGERread-onlymandatory
airIRRP100UnitStatusDehumidifyDemand
OBJECT-TYPE
The amount of dehumidification the unit is demanding in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.17INTEGERread-onlymandatory
airIRRP100UnitStatusDehumidifyOutput
OBJECT-TYPE
The actual dehumidification output of the unit in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.18INTEGERread-onlymandatory
airIRRP100UnitStatusReheatDemand
OBJECT-TYPE
The amount of heating the unit is demanding from the electric heater in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.19INTEGERread-onlymandatory
airIRRP100UnitStatusReheatOutput
OBJECT-TYPE
The actual heating output of the unit in percent.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.20INTEGERread-onlymandatory
airIRRP100UnitStatusInputState
OBJECT-TYPE
The state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.21INTEGER {open(1), closed(2)}read-onlymandatory
airIRRP100UnitStatusOutputState
OBJECT-TYPE
The state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.22INTEGER {open(1), closed(2)}read-onlymandatory
airIRRP100UnitStatusRackInletTemperature1US
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.23INTEGERread-onlymandatory
airIRRP100UnitStatusRackInletTemperature1Metric
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.24INTEGERread-onlymandatory
airIRRP100UnitStatusRackInletTemperature2US
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.25INTEGERread-onlymandatory
airIRRP100UnitStatusRackInletTemperature2Metric
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.26INTEGERread-onlymandatory
airIRRP100UnitStatusRackInletTemperature3US
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.27INTEGERread-onlymandatory
airIRRP100UnitStatusRackInletTemperature3Metric
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.28INTEGERread-onlymandatory
airIRRP100UnitStatusFilterDPUS
OBJECT-TYPE
The unit air filter differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.29INTEGERread-onlymandatory
airIRRP100UnitStatusFilterDPMetric
OBJECT-TYPE
The unit air filter differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.30INTEGERread-onlymandatory
airIRRP100UnitStatusContainmtDPUS
OBJECT-TYPE
The unit containment differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.31INTEGERread-onlymandatory
airIRRP100UnitStatusContainmtDPMetric
OBJECT-TYPE
The unit containment differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.32INTEGERread-onlymandatory
airIRRP100UnitStatusHumidifierCurrent
OBJECT-TYPE
The humidifier current of the unit in tenths of amperes.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.33INTEGERread-onlymandatory
airIRRP100UnitStatusHumidifierWaterConductivity
OBJECT-TYPE
The water conductivity in the humidifier of the unit in microSiemens/cm.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.34INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveSpeed
OBJECT-TYPE
The compressor drive speed in hundredths of Hertz.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDrivePower
OBJECT-TYPE
The compressor drive power consumption in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.36INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveVoltage
OBJECT-TYPE
The compressor drive voltage consumption in tenths of volts.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.37INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveCurrent
OBJECT-TYPE
The compressor drive voltage consumption in tenths of amperes.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.38INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveDCLinkVoltage
OBJECT-TYPE
The compressor drive DC link voltage in tenths of volts.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.39INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveHeatSinkTempUS
OBJECT-TYPE
The temperature of the compressor drive heatsink in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.40INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric
OBJECT-TYPE
The temperature of the compressor drive heatsink in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.41INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveControlCardTempUS
OBJECT-TYPE
The temperature of the compressor drive control card in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.42INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveControlCardTempMetric
OBJECT-TYPE
The temperature of the compressor drive control card in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.43INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveWarningStatus
OBJECT-TYPE
The four byte warning status of the compressor drive in hexadecimal.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.44INTEGERread-onlymandatory
airIRRP100UnitStatusCompressorDriveAlarmStatus
OBJECT-TYPE
The four byte alarm status of the compressor drive in hexadecimal.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.45INTEGERread-onlymandatory
airIRRP100UnitStatusSuctionPressureUS
OBJECT-TYPE
Unit suction pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.46INTEGERread-onlymandatory
airIRRP100UnitStatusSuctionPressureMetric
OBJECT-TYPE
Unit suction pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.47INTEGERread-onlymandatory
airIRRP100UnitStatusDischargePressureUS
OBJECT-TYPE
Unit discharge pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.48INTEGERread-onlymandatory
airIRRP100UnitStatusDischargePressureMetric
OBJECT-TYPE
Unit discharge pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.49INTEGERread-onlymandatory
airIRRP100UnitStatusLeakSensor
OBJECT-TYPE
The state (no-leak/leak) of the leak sensor.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.50INTEGER {no-leak(1), leak(2)}read-onlymandatory
airIRRP100UnitRunHours
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3
airIRRP100UnitRunHoursAirFilter
OBJECT-TYPE
Unit air filter run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.1INTEGERread-onlymandatory
airIRRP100UnitRunHoursCondensatePump
OBJECT-TYPE
Unit condensate pump run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.2INTEGERread-onlymandatory
airIRRP100UnitRunHoursHumidifier
OBJECT-TYPE
Unit fan right power supply run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.3INTEGERread-onlymandatory
airIRRP100UnitRunHoursFan1
OBJECT-TYPE
Unit fan 1 run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.4INTEGERread-onlymandatory
airIRRP100UnitRunHoursHeater1
OBJECT-TYPE
Unit heater 1 run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.5INTEGERread-onlymandatory
airIRRP100UnitRunHoursFan2
OBJECT-TYPE
Unit fan 2 run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.6INTEGERread-onlymandatory
airIRRP100UnitRunHoursHeater2
OBJECT-TYPE
Unit Heater 2 run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.7INTEGERread-onlymandatory
airIRRP100UnitRunHoursCompressor
OBJECT-TYPE
Unit compressor run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.8INTEGERread-onlymandatory
airIRRP100UnitRunHoursSystem
OBJECT-TYPE
Total system run hours.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.3.9INTEGERread-onlymandatory
airIRRP100UnitServiceIntervals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4
airIRRP100UnitServiceIntervalAirFilter
OBJECT-TYPE
Air filter service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.1INTEGERread-writemandatory
airIRRP100UnitServiceIntervalAirFilterAlarm
OBJECT-TYPE
The air filter service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.2INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitServiceIntervalHumidifier
OBJECT-TYPE
Humidifier service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.3INTEGERread-writemandatory
airIRRP100UnitServiceIntervalHumidifierAlarm
OBJECT-TYPE
The humidifier service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.4INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitServiceIntervalHeater
OBJECT-TYPE
Heater service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.5INTEGERread-writemandatory
airIRRP100UnitServiceIntervalHeaterAlarm
OBJECT-TYPE
The heater service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.6INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitServiceIntervalCompressor
OBJECT-TYPE
Compressor service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.7INTEGERread-writemandatory
airIRRP100UnitServiceIntervalCompressorAlarm
OBJECT-TYPE
The compressor service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.8INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitServiceIntervalCondensatePump
OBJECT-TYPE
Condensate pump service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.9INTEGERread-writemandatory
airIRRP100UnitServiceIntervalCondensatePumpAlarm
OBJECT-TYPE
The condensate pump service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.10INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitServiceIntervalFans
OBJECT-TYPE
Fans service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.11INTEGERread-writemandatory
airIRRP100UnitServiceIntervalFansAlarm
OBJECT-TYPE
The fans service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.4.12INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5
airIRRP100UnitThresholdsRackInletHighTempUS
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.1INTEGERread-writemandatory
airIRRP100UnitThresholdsRackInletHighTempMetric
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.2INTEGERread-writemandatory
airIRRP100UnitThresholdsSupplyAirHighTempUS
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.3INTEGERread-writemandatory
airIRRP100UnitThresholdsSupplyAirHighTempMetric
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.4INTEGERread-writemandatory
airIRRP100UnitThresholdsReturnAirHighTempUS
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.5INTEGERread-writemandatory
airIRRP100UnitThresholdsReturnAirHighTempMetric
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.6INTEGERread-writemandatory
airIRRP100UnitThresholdsSupplyHumidityHigh
OBJECT-TYPE
Unit supply humidity high threshold in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.7INTEGERread-writemandatory
airIRRP100UnitThresholdsSupplyHumidityLow
OBJECT-TYPE
Unit supply humidity low threshold in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.5.8INTEGERread-writemandatory
airIRRP100UnitConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6
airIRRP100UnitConfigStartupDelay
OBJECT-TYPE
The startup delay in seconds.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.1INTEGERread-writemandatory
airIRRP100UnitConfigCoolCapacity
OBJECT-TYPE
The cooling capacity options setting.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.2INTEGER {automatic(1), maximum(2)}read-writemandatory
airIRRP100UnitConfigIdleOnLeakDetect
OBJECT-TYPE
The idle on leak options setting.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.3INTEGER {yes(1), no(2)}read-writemandatory
airIRRP100UnitConfigInputNormalState
OBJECT-TYPE
The normal state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.4INTEGER {open(1), closed(2)}read-writemandatory
airIRRP100UnitConfigOutputNormalState
OBJECT-TYPE
The normal state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.5INTEGER {open(1), closed(2)}read-writemandatory
airIRRP100UnitConfigOutputSource
OBJECT-TYPE
The source of output relay change.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.6INTEGER {anyAlarm(1), criticalAlarm(2)}read-writemandatory
airIRRP100UnitConfigHumidifyEnable
OBJECT-TYPE
Enable/disable humidification.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.7INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitConfigHumidifierControl
OBJECT-TYPE
The humidifier drain control.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.8INTEGER {auto(1), drainOff(2)}read-writemandatory
airIRRP100UnitConfigDehumidifyEnable
OBJECT-TYPE
Enable/disable dehumidification.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.9INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitConfigReheatEnable
OBJECT-TYPE
Enable/disable reheat.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.10INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitConfigHeatAssistEnable
OBJECT-TYPE
Enable/disable heat assist.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.11INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP100UnitConfigPowerSourceConfig
OBJECT-TYPE
Configure the input power source: (1) single feed or (2) dual feed.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.12INTEGER {single(1), dual(2)}read-writemandatory
airIRRP100UnitConfigUnitRoleOverride
OBJECT-TYPE
When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.13INTEGER {automatic(1), forcedOn(2)}read-writemandatory
airIRRP100UnitConfigSecondaryPowerFeedCapability
OBJECT-TYPE
Available on chilled water units. When the power source config setting is set to dual, setting this value to reduced (2) will inhibit the heater and humdifier when the unit is being powered from the secondary input.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.14INTEGER {full(1), reduced(2)}read-writemandatory
airIRRP100UnitConfigIdleOnCoolFail
OBJECT-TYPE
When this OID value is (1) enable, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals.
1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.15INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2
airIRRP500Group
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.1
airIRRP500GroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1
airIRRP500GroupStatusAirFlowUS
OBJECT-TYPE
Group air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.1INTEGERread-onlymandatory
airIRRP500GroupStatusAirFlowMetric
OBJECT-TYPE
Group air flow in liters per second.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.2INTEGERread-onlymandatory
airIRRP500GroupStatusMaxRackInletTempUS
OBJECT-TYPE
Group maximum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.3INTEGERread-onlymandatory
airIRRP500GroupStatusMaxRackInletTempMetric
OBJECT-TYPE
Group maximum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.4INTEGERread-onlymandatory
airIRRP500GroupStatusMinRackInletTempUS
OBJECT-TYPE
Group minimum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.5INTEGERread-onlymandatory
airIRRP500GroupStatusMinRackInletTempMetric
OBJECT-TYPE
Group minimum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.6INTEGERread-onlymandatory
airIRRP500GroupStatusCoolDemand
OBJECT-TYPE
Group coolant demand in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.7INTEGERread-onlymandatory
airIRRP500GroupStatusCoolOutput
OBJECT-TYPE
Group coolant output in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.8INTEGERread-onlymandatory
airIRRP500GroupStatusHumidifyDemand
OBJECT-TYPE
The amount of humidification the group is demanding from the humidifiers in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.9INTEGERread-onlymandatory
airIRRP500GroupStatusHumidifyOutput
OBJECT-TYPE
The actual amount of humidification the group is supplying in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.10INTEGERread-onlymandatory
airIRRP500GroupStatusDehumidifyDemand
OBJECT-TYPE
The amount of dehumidification the group is demanding from the electric heaters in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.11INTEGERread-onlymandatory
airIRRP500GroupStatusDehumidifyOutput
OBJECT-TYPE
The actual amount of dehumidification the group is supplying in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.12INTEGERread-onlymandatory
airIRRP500GroupStatusReheatDemand
OBJECT-TYPE
The amount of heating the group is demanding from the electric heaters in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.13INTEGERread-onlymandatory
airIRRP500GroupStatusReheatOutput
OBJECT-TYPE
The actual amount of heating the group is supplying in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.14INTEGERread-onlymandatory
airIRRP500GroupStatusActiveFlowControlStatus
OBJECT-TYPE
Status of the active flow control system.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.15INTEGER {under(1), okay(2), over(3), notApplicable(4)}read-onlymandatory
airIRRP500GroupStatusDewPointTempUS
OBJECT-TYPE
Group average dew point temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.16INTEGERread-onlymandatory
airIRRP500GroupStatusDewPointTempMetric
OBJECT-TYPE
Group average dew point temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.1.17INTEGERread-onlymandatory
airIRRP500GroupSetpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2
airIRRP500GroupSetpointsCoolUS
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.1INTEGERread-writemandatory
airIRRP500GroupSetpointsCoolMetric
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.2INTEGERread-writemandatory
airIRRP500GroupSetpointsSupplyAirUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.3INTEGERread-writemandatory
airIRRP500GroupSetpointsSupplyAirMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.4INTEGERread-writemandatory
airIRRP500GroupSetpointsHumidify
OBJECT-TYPE
Group humidify setpoint in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.5INTEGERread-writemandatory
airIRRP500GroupSetpointsDehumidify
OBJECT-TYPE
Group dehumidify setpoint in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.6INTEGERread-writemandatory
airIRRP500GroupSetpointsDehumidifyDeadband
OBJECT-TYPE
Group dehumidify deadband in percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.7INTEGERread-writemandatory
airIRRP500GroupSetpointsReheatUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.8INTEGERread-writemandatory
airIRRP500GroupSetpointsReheatMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.9INTEGERread-writemandatory
airIRRP500GroupSetpointsFanSpeedPreference
OBJECT-TYPE
The preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.10INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)}read-writemandatory
airIRRP500GroupSetpointsFanSpeedControl
OBJECT-TYPE
The fan speed control setting.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.11INTEGER {automatic(1), manual(2)}read-writemandatory
airIRRP500GroupSetpointsActiveFlowControlBias
OBJECT-TYPE
The active flow control bias setting.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.2.12INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)}read-writemandatory
airIRRP500GroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3
airIRRP500GroupConfigNumberofCoolingUnits
OBJECT-TYPE
The number of cooling units.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.1INTEGERread-writemandatory
airIRRP500GroupConfigConfigurationType
OBJECT-TYPE
The group configuration type.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.2INTEGER {racs(1), hacs(2), in-row(3), cacs(4)}read-writemandatory
airIRRP500GroupConfigPercentGlycol
OBJECT-TYPE
The glycol mixture in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.3INTEGERread-writemandatory
airIRRP500GroupConfigCoolGainP
OBJECT-TYPE
The gain component of the cool PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.4INTEGERread-writemandatory
airIRRP500GroupConfigCoolResetRateI
OBJECT-TYPE
The integral component of the cool PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.5INTEGERread-writemandatory
airIRRP500GroupConfigCoolDerivativeD
OBJECT-TYPE
The derivative component of the cool PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.6INTEGERread-writemandatory
airIRRP500GroupConfigHumidifySensitivityBand
OBJECT-TYPE
The percent relative humidity below the setpoint that will cause the humidifier to run at 100% capacity.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.7INTEGERread-writemandatory
airIRRP500GroupConfigReheatGainP
OBJECT-TYPE
The gain component of the reheat PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.8INTEGERread-writemandatory
airIRRP500GroupConfigReheatResetRateI
OBJECT-TYPE
The integral component of the reheat PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.9INTEGERread-writemandatory
airIRRP500GroupConfigReheatDerivativeD
OBJECT-TYPE
The derivative component of the reheat PID in hundredths.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.10INTEGERread-writemandatory
airIRRP500GroupConfigMaxFanSpeed
OBJECT-TYPE
The maximum desired fan speed setting in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.11INTEGERread-writemandatory
airIRRP500GroupConfigNumberofBackupUnits
OBJECT-TYPE
The number of backup units.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.12INTEGERread-writemandatory
airIRRP500GroupConfigRuntimeBalancingEnable
OBJECT-TYPE
Enable or disable runtime balancing feature.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.13INTEGER {disable(1), enable(2)}read-writemandatory
airIRRP500GroupConfigLoadAssistEnable
OBJECT-TYPE
Enable or disable load assist feature.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.14INTEGER {disable(1), enable(2)}read-writemandatory
airIRRP500GroupConfigFullRPBackups
OBJECT-TYPE
The number of full featured RPs that can be used as backup units.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.15INTEGERread-writemandatory
airIRRP500GroupConfigNumberOfActiveFlowControllers
OBJECT-TYPE
The number of active flow controllers present in the group.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.16INTEGERread-writemandatory
airIRRP500GroupConfigActiveFlowControllerLampTest
OBJECT-TYPE
Turns off/on the active flow controller lamp test.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.17INTEGER {off(1), on(2)}read-writemandatory
airIRRP500GroupConfigAltitudeUS
OBJECT-TYPE
The group altitude of the units above sea level in feet.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.18INTEGERread-writemandatory
airIRRP500GroupConfigAltitudeMetric
OBJECT-TYPE
The group altitude of the units above sea level in meters.
1.3.6.1.4.1.318.1.1.13.3.3.2.1.3.19INTEGERread-writemandatory
airIRRP500Unit
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2
airIRRP500UnitIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1
airIRRP500UnitIdentID
OBJECT-TYPE
The unit identification number.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.1INTEGERread-writemandatory
airIRRP500UnitIdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.2DisplayStringread-writemandatory
airIRRP500UnitIdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.3DisplayStringread-writemandatory
airIRRP500UnitIdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.4DisplayStringread-onlymandatory
airIRRP500UnitIdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.5DisplayStringread-onlymandatory
airIRRP500UnitIdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.6DisplayStringread-onlymandatory
airIRRP500UnitIdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.7DisplayStringread-onlymandatory
airIRRP500UnitIdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.1.8DisplayStringread-onlymandatory
airIRRP500UnitStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2
airIRRP500UnitStatusOperateMode
OBJECT-TYPE
The cooling unit operating mode.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.1INTEGER {standby(1), on(2), idle(3), prestart(4), backup(5), assist(6)}read-onlymandatory
airIRRP500UnitStatusMaximumRackInletTempUS
OBJECT-TYPE
The maximum unit rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.2INTEGERread-onlymandatory
airIRRP500UnitStatusMaximumRackInletTempMetric
OBJECT-TYPE
The maximum unit rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.3INTEGERread-onlymandatory
airIRRP500UnitStatusSupplyAirTempUS
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.4INTEGERread-onlymandatory
airIRRP500UnitStatusSupplyAirTempMetric
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.5INTEGERread-onlymandatory
airIRRP500UnitStatusReturnAirTempUS
OBJECT-TYPE
The unit return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.6INTEGERread-onlymandatory
airIRRP500UnitStatusReturnAirTempMetric
OBJECT-TYPE
The unit return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.7INTEGERread-onlymandatory
airIRRP500UnitStatusSupplyHumidity
OBJECT-TYPE
The relative humidity of the supply air in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8INTEGERread-onlymandatory
airIRRP500UnitStatusReturnHumidity
OBJECT-TYPE
The relative humidity of the return air in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.9INTEGERread-onlymandatory
airIRRP500UnitStatusAirFlowUS
OBJECT-TYPE
The unit air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.10INTEGERread-onlymandatory
airIRRP500UnitStatusAirFlowMetric
OBJECT-TYPE
The unit air flow in hundredths of liters per second.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.11INTEGERread-onlymandatory
airIRRP500UnitStatusFanSpeed
OBJECT-TYPE
The unit average fan speed in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.12INTEGERread-onlymandatory
airIRRP500UnitStatusCoolDemand
OBJECT-TYPE
The unit cooling demand in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.13INTEGERread-onlymandatory
airIRRP500UnitStatusCoolOutput
OBJECT-TYPE
The unit cooling output in tenths of kiloWatts.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.14INTEGERread-onlymandatory
airIRRP500UnitStatusHumidifyDemand
OBJECT-TYPE
The amount of humidification the unit is demanding from the humidifier in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.15INTEGERread-onlymandatory
airIRRP500UnitStatusHumidifyOutput
OBJECT-TYPE
The actual humidification output of the unit in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.16INTEGERread-onlymandatory
airIRRP500UnitStatusDehumidifyDemand
OBJECT-TYPE
The amount of dehumidification the unit is demanding in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.17INTEGERread-onlymandatory
airIRRP500UnitStatusDehumidifyOutput
OBJECT-TYPE
The actual dehumidification output of the unit in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.18INTEGERread-onlymandatory
airIRRP500UnitStatusReheatDemand
OBJECT-TYPE
The amount of heating the unit is demanding from the electric heater in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.19INTEGERread-onlymandatory
airIRRP500UnitStatusReheatOutput
OBJECT-TYPE
The actual heating output of the unit in percent.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.20INTEGERread-onlymandatory
airIRRP500UnitStatusInputState
OBJECT-TYPE
The state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.21INTEGER {open(1), closed(2)}read-onlymandatory
airIRRP500UnitStatusOutputState
OBJECT-TYPE
The state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.22INTEGER {open(1), closed(2)}read-onlymandatory
airIRRP500UnitStatusRackInletTemperature1US
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.23INTEGERread-onlymandatory
airIRRP500UnitStatusRackInletTemperature1Metric
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.24INTEGERread-onlymandatory
airIRRP500UnitStatusRackInletTemperature2US
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.25INTEGERread-onlymandatory
airIRRP500UnitStatusRackInletTemperature2Metric
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.26INTEGERread-onlymandatory
airIRRP500UnitStatusRackInletTemperature3US
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.27INTEGERread-onlymandatory
airIRRP500UnitStatusRackInletTemperature3Metric
OBJECT-TYPE
The unit rack inlet temperature sensor in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.28INTEGERread-onlymandatory
airIRRP500UnitStatusContainmtDPUS
OBJECT-TYPE
The unit containment differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.29INTEGERread-onlymandatory
airIRRP500UnitStatusContainmtDPMetric
OBJECT-TYPE
The unit containment differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.30INTEGERread-onlymandatory
airIRRP500UnitStatusFilterDPUS
OBJECT-TYPE
The unit air filter differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.31INTEGERread-onlymandatory
airIRRP500UnitStatusFilterDPMetric
OBJECT-TYPE
The unit air filter differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.32INTEGERread-onlymandatory
airIRRP500UnitStatusHumidifierCurrent
OBJECT-TYPE
The humidifier current of the unit in tenths of amperes.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.33INTEGERread-onlymandatory
airIRRP500UnitStatusHumidifierWaterConductivity
OBJECT-TYPE
The water conductivity in the humidifier of the unit in microSiemens/cm.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.34INTEGERread-onlymandatory
airIRRP500UnitStatusActivePowerSource
OBJECT-TYPE
The power source that is powering the unit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.35INTEGER {sourceA(1), sourceB(2)}read-onlymandatory
airIRRP500UnitStatusFluidValvePosition
OBJECT-TYPE
The fluid valve position in percent open.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.36INTEGERread-onlymandatory
airIRRP500UnitStatusFluidFlowUS
OBJECT-TYPE
The fluid flow in tenths of gallons per minute.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.37INTEGERread-onlymandatory
airIRRP500UnitStatusFluidFlowMetric
OBJECT-TYPE
The fluid flow in hundredths of liters per second.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.38INTEGERread-onlymandatory
airIRRP500UnitStatusEnteringFluidTemperatureUS
OBJECT-TYPE
The temperature of the entering fluid in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.39INTEGERread-onlymandatory
airIRRP500UnitStatusEnteringFluidTemperatureMetric
OBJECT-TYPE
The temperature of the entering fluid in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.40INTEGERread-onlymandatory
airIRRP500UnitStatusLeavingFluidTemperatureUS
OBJECT-TYPE
The temperature of the Leaving fluid in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.41INTEGERread-onlymandatory
airIRRP500UnitStatusLeavingFluidTemperatureMetric
OBJECT-TYPE
The temperature of the Leaving fluid in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.42INTEGERread-onlymandatory
airIRRP500UnitStatusLeakSensor
OBJECT-TYPE
The state (no-leak/leak) of the leak sensor.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.43INTEGER {no-leak(1), leak(2)}read-onlymandatory
airIRRP500UnitRunHours
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3
airIRRP500UnitRunHoursAirFilter
OBJECT-TYPE
Unit air filter run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.1INTEGERread-onlymandatory
airIRRP500UnitRunHoursCondensatePump
OBJECT-TYPE
Unit condensate pump run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.2INTEGERread-onlymandatory
airIRRP500UnitRunHoursHumidifier
OBJECT-TYPE
Unit fan right power supply run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.3INTEGERread-onlymandatory
airIRRP500UnitRunHoursFan1
OBJECT-TYPE
Unit fan 1 run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.4INTEGERread-onlymandatory
airIRRP500UnitRunHoursHeater1
OBJECT-TYPE
Unit heater 1 run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.5INTEGERread-onlymandatory
airIRRP500UnitRunHoursFan2
OBJECT-TYPE
Unit fan 2 run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.6INTEGERread-onlymandatory
airIRRP500UnitRunHoursHeater2
OBJECT-TYPE
Unit Heater 2 run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.7INTEGERread-onlymandatory
airIRRP500UnitRunHoursFan3
OBJECT-TYPE
Unit fan 3 run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.8INTEGERread-onlymandatory
airIRRP500UnitRunHoursHeater3
OBJECT-TYPE
Unit heater 3 run hours in hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.9INTEGERread-onlymandatory
airIRRP500UnitRunHoursSystem
OBJECT-TYPE
Total system run hours.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.3.10INTEGERread-onlymandatory
airIRRP500UnitServiceIntervals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4
airIRRP500UnitServiceIntervalAirFilter
OBJECT-TYPE
Air filter service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.1INTEGERread-writemandatory
airIRRP500UnitServiceIntervalAirFilterAlarm
OBJECT-TYPE
The air filter service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.2INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitServiceIntervalHumidifier
OBJECT-TYPE
Humidifier service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.3INTEGERread-writemandatory
airIRRP500UnitServiceIntervalHumidifierAlarm
OBJECT-TYPE
The humidifier service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.4INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitServiceIntervalHeater
OBJECT-TYPE
Heater service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.5INTEGERread-writemandatory
airIRRP500UnitServiceIntervalHeaterAlarm
OBJECT-TYPE
The heater service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.6INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitServiceIntervalCondensatePump
OBJECT-TYPE
Condensate pump service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.7INTEGERread-writemandatory
airIRRP500UnitServiceIntervalCondensatePumpAlarm
OBJECT-TYPE
The condensate pump service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.8INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitServiceIntervalFans
OBJECT-TYPE
Fans service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.9INTEGERread-writemandatory
airIRRP500UnitServiceIntervalFansAlarm
OBJECT-TYPE
The fans service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.4.10INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5
airIRRP500UnitThresholdsRackInletHighTempUS
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.1INTEGERread-writemandatory
airIRRP500UnitThresholdsRackInletHighTempMetric
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.2INTEGERread-writemandatory
airIRRP500UnitThresholdsSupplyAirHighTempUS
OBJECT-TYPE
Unit supply air temperature high threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.3INTEGERread-writemandatory
airIRRP500UnitThresholdsSupplyAirHighTempMetric
OBJECT-TYPE
Unit supply air high temperature high threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.4INTEGERread-writemandatory
airIRRP500UnitThresholdsReturnAirHighTempUS
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.5INTEGERread-writemandatory
airIRRP500UnitThresholdsReturnAirHighTempMetric
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.6INTEGERread-writemandatory
airIRRP500UnitThresholdsReturnHumidityHigh
OBJECT-TYPE
Unit return humidity high threshold in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.7INTEGERread-writemandatory
airIRRP500UnitThresholdsReturnHumidityLow
OBJECT-TYPE
Unit return humidity low threshold in tenths of percent relative humidity.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.8INTEGERread-writemandatory
airIRRP500UnitThresholdsEnteringFluidHighTempUS
OBJECT-TYPE
Entering fluid high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.9INTEGERread-writemandatory
airIRRP500UnitThresholdsEnteringFluidHighTempMetric
OBJECT-TYPE
Entering fluid high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.5.10INTEGERread-writemandatory
airIRRP500UnitConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6
airIRRP500UnitConfigStartupDelay
OBJECT-TYPE
The startup delay in seconds.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.1INTEGERread-writemandatory
airIRRP500UnitConfigCoolCapacity
OBJECT-TYPE
The cooling capacity options setting.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.2INTEGER {automatic(1), maximum(2)}read-writemandatory
airIRRP500UnitConfigIdleOnLeakDetect
OBJECT-TYPE
The idle on leak options setting.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.3INTEGER {yes(1), no(2)}read-writemandatory
airIRRP500UnitConfigInputNormalState
OBJECT-TYPE
The normal state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.4INTEGER {open(1), closed(2)}read-writemandatory
airIRRP500UnitConfigOutputNormalState
OBJECT-TYPE
The normal state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.5INTEGER {open(1), closed(2)}read-writemandatory
airIRRP500UnitConfigOutputSource
OBJECT-TYPE
The source of output relay change.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.6INTEGER {anyAlarm(1), criticalAlarm(2)}read-writemandatory
airIRRP500UnitConfigHumidifyEnable
OBJECT-TYPE
Enable/disable humidification.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.7INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitConfigHumidifierControl
OBJECT-TYPE
The humidifier drain control.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.8INTEGER {auto(1), drainOff(2)}read-writemandatory
airIRRP500UnitConfigDehumidifyEnable
OBJECT-TYPE
Enable/disable dehumidification.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.9INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitConfigReheatEnable
OBJECT-TYPE
Enable/disable reheat.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.10INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitConfigHeatAssistEnable
OBJECT-TYPE
Enable/disable heat assist.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.11INTEGER {enable(1), disable(2)}read-writemandatory
airIRRP500UnitConfigPowerSourceConfig
OBJECT-TYPE
Configure the input power source: (1) single feed or (2) dual feed.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.12INTEGER {single(1), dual(2)}read-writemandatory
airIRRP500UnitConfigUnitRoleOverride
OBJECT-TYPE
When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.13INTEGER {automatic(1), forcedOn(2)}read-writemandatory
airIRRP500UnitConfigSecondaryPowerFeedCapability
OBJECT-TYPE
Available on chilled water units. When the power source config setting is set to dual, setting this value to reduced (2) will inhibit the heater and humdifier when the unit is being powered from the secondary input.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.14INTEGER {full(1), reduced(2)}read-writemandatory
airIRRP500UnitConfigIdleOnCoolFail
OBJECT-TYPE
When this OID value is (1) enable, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals.
1.3.6.1.4.1.318.1.1.13.3.3.2.2.6.15INTEGER {enable(1), disable(2)}read-writemandatory
airIRSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4
airIRSCUnit
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1
airIRSCUnitIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.1
airIRSCUnitIdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.1DisplayStringread-writemandatory
airIRSCUnitIdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.2DisplayStringread-writemandatory
airIRSCUnitIdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.3DisplayStringread-onlymandatory
airIRSCUnitIdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.4DisplayStringread-onlymandatory
airIRSCUnitIdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.5DisplayStringread-onlymandatory
airIRSCUnitIdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.6DisplayStringread-onlymandatory
airIRSCUnitIdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.3.4.1.1.7DisplayStringread-onlymandatory
airIRSCUnitStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.2
airIRSCUnitStatusOperateMode
OBJECT-TYPE
The cooling unit operating mode.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.1INTEGER {standby(1), on(2), idle(3)}read-onlymandatory
airIRSCUnitStatusCoolOutput
OBJECT-TYPE
The unit cooling output in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.2INTEGERread-onlymandatory
airIRSCUnitStatusCoolDemand
OBJECT-TYPE
The unit cooling demand in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.3INTEGERread-onlymandatory
airIRSCUnitStatusAirFlowUS
OBJECT-TYPE
The unit air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.4INTEGERread-onlymandatory
airIRSCUnitStatusAirFlowMetric
OBJECT-TYPE
The unit air flow in liters per second.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.5INTEGERread-onlymandatory
airIRSCUnitStatusRackInletTempUS
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.6INTEGERread-onlymandatory
airIRSCUnitStatusRackInletTempMetric
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.7INTEGERread-onlymandatory
airIRSCUnitStatusSupplyAirTempUS
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.8INTEGERread-onlymandatory
airIRSCUnitStatusSupplyAirTempMetric
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.9INTEGERread-onlymandatory
airIRSCUnitStatusReturnAirTempUS
OBJECT-TYPE
The unit return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.10INTEGERread-onlymandatory
airIRSCUnitStatusReturnAirTempMetric
OBJECT-TYPE
The unit return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.11INTEGERread-onlymandatory
airIRSCUnitStatusSuctionTempUS
OBJECT-TYPE
The unit suction temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.12INTEGERread-onlymandatory
airIRSCUnitStatusSuctionTempMetric
OBJECT-TYPE
The unit suction temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.13INTEGERread-onlymandatory
airIRSCUnitStatusSuperheatTempUS
OBJECT-TYPE
The unit superheat temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.14INTEGERread-onlymandatory
airIRSCUnitStatusSuperheatTempMetric
OBJECT-TYPE
The unit superheat temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.15INTEGERread-onlymandatory
airIRSCUnitStatusContainmtDPUS
OBJECT-TYPE
The unit containment differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.16INTEGERread-onlymandatory
airIRSCUnitStatusContainmtDPMetric
OBJECT-TYPE
The unit containment differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.17INTEGERread-onlymandatory
airIRSCUnitStatusFilterDPUS
OBJECT-TYPE
The unit air filter differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.18INTEGERread-onlymandatory
airIRSCUnitStatusFilterDPMetric
OBJECT-TYPE
The unit air filter differential pressure in Pa.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.19INTEGERread-onlymandatory
airIRSCUnitStatusSuctionPressureUS
OBJECT-TYPE
Unit suction pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.3.4.1.2.20INTEGERread-onlymandatory
airIRSCUnitStatusSuctionPressureMetric
OBJECT-TYPE
Unit suction pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.3.4.1.2.21INTEGERread-onlymandatory
airIRSCUnitStatusDischargePressureUS
OBJECT-TYPE
Unit discharge pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.3.4.1.2.22INTEGERread-onlymandatory
airIRSCUnitStatusDischargePressureMetric
OBJECT-TYPE
Unit discharge pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.3.4.1.2.23INTEGERread-onlymandatory
airIRSCUnitStatusEvaporatorFanSpeed
OBJECT-TYPE
The unit average evaporator fan speed in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.24INTEGERread-onlymandatory
airIRSCUnitStatusCondenserFanSpeed
OBJECT-TYPE
The unit average condenser fan speed in tenths of percent.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.25INTEGERread-onlymandatory
airIRSCUnitStatusInputState
OBJECT-TYPE
The state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.26INTEGER {open(1), closed(2)}read-onlymandatory
airIRSCUnitStatusOutputState
OBJECT-TYPE
The state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.27INTEGER {open(1), closed(2)}read-onlymandatory
airIRSCUnitStatusCondOutletTempUS
OBJECT-TYPE
The unit condenser outlet air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.28INTEGERread-onlymandatory
airIRSCUnitStatusCondOutletTempMetric
OBJECT-TYPE
The unit condenser outlet air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.29INTEGERread-onlymandatory
airIRSCUnitStatusCondInletTempUS
OBJECT-TYPE
The unit condenser inlet air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.30INTEGERread-onlymandatory
airIRSCUnitStatusCondInletTempMetric
OBJECT-TYPE
The unit condenser inlet air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.31INTEGERread-onlymandatory
airIRSCUnitStatusCompressor
OBJECT-TYPE
The state (off/on) of the compressor.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.32INTEGER {off(1), on(2)}read-onlymandatory
airIRSCUnitStatusLeakSensor
OBJECT-TYPE
The state (no-leak/leak) of the leak sensor.
1.3.6.1.4.1.318.1.1.13.3.4.1.2.33INTEGER {no-leak(1), leak(2)}read-onlymandatory
airIRSCUnitRunHours
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.3
airIRSCUnitRunHoursAirFilter
OBJECT-TYPE
Unit air filter run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.1INTEGERread-onlymandatory
airIRSCUnitRunHoursEvaporatorFan1
OBJECT-TYPE
Unit evaporator fan 1 run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.2INTEGERread-onlymandatory
airIRSCUnitRunHoursEvaporatorFan2
OBJECT-TYPE
Unit evaporator fan 2 run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.3INTEGERread-onlymandatory
airIRSCUnitRunHoursEvaporatorFan3
OBJECT-TYPE
Unit evaporator fan 3 run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.4INTEGERread-onlymandatory
airIRSCUnitRunHoursCondenserFan1
OBJECT-TYPE
Unit condenser fan 1 run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.5INTEGERread-onlymandatory
airIRSCUnitRunHoursCondenserFan2
OBJECT-TYPE
Unit condenser fan 2 run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.6INTEGERread-onlymandatory
airIRSCUnitRunHoursCondenserFan3
OBJECT-TYPE
Unit condenser fan 3 run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.7INTEGERread-onlymandatory
airIRSCUnitRunHoursFanPowerSupplyLeft
OBJECT-TYPE
Unit fan left power supply run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.8INTEGERread-onlymandatory
airIRSCUnitRunHoursFanPowerSupplyRight
OBJECT-TYPE
Unit fan right power supply run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.9INTEGERread-onlymandatory
airIRSCUnitRunHoursCondensatePump
OBJECT-TYPE
Unit condensate pump run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.10INTEGERread-onlymandatory
airIRSCUnitRunHoursCompressor
OBJECT-TYPE
Unit compressor run hours.
1.3.6.1.4.1.318.1.1.13.3.4.1.3.11INTEGERread-onlymandatory
airIRSCUnitServiceIntervals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.4
airIRSCUnitServiceIntervalsAirFilter
OBJECT-TYPE
Air filter service interval in weeks.
1.3.6.1.4.1.318.1.1.13.3.4.1.4.1INTEGERread-writemandatory
airIRSCUnitServiceIntervalsAirFilterAlarm
OBJECT-TYPE
The air filter service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.3.4.1.4.2INTEGER {enable(1), disable(2)}read-writemandatory
airIRSCUnitThresholds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.5
airIRSCUnitThresholdsRackInletHighTempUS
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.5.1INTEGERread-writemandatory
airIRSCUnitThresholdsRackInletHighTempMetric
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.5.2INTEGERread-writemandatory
airIRSCUnitThresholdsSupplyAirHighTempUS
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.5.3INTEGERread-writemandatory
airIRSCUnitThresholdsSupplyAirHighTempMetric
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.5.4INTEGERread-writemandatory
airIRSCUnitThresholdsReturnAirHighTempUS
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.5.5INTEGERread-writemandatory
airIRSCUnitThresholdsReturnAirHighTempMetric
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.5.6INTEGERread-writemandatory
airIRSCUnitSetpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.6
airIRSCUnitSetptsCoolSetpointUS
OBJECT-TYPE
Unit cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.1INTEGERread-writemandatory
airIRSCUnitSetptsCoolSetpointMetric
OBJECT-TYPE
Unit cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.2INTEGERread-writemandatory
airIRSCUnitSetptsCoolDeadbandUS
OBJECT-TYPE
Unit cooling deadband in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.3INTEGERread-writemandatory
airIRSCUnitSetptsCoolDeadbandMetric
OBJECT-TYPE
Unit cooling deadband in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.4INTEGERread-writemandatory
airIRSCUnitSetptsFanSpeedPreference
OBJECT-TYPE
The preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.5AirIRSCFanSpeedPreferenceread-writemandatory
airIRSCUnitSetptsSupplyAirSetpointUS
OBJECT-TYPE
Unit supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.6INTEGERread-writemandatory
airIRSCUnitSetptsSupplyAirSetpointMetric
OBJECT-TYPE
Unit supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.1.6.7INTEGERread-writemandatory
airIRSCUnitConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.1.7
airIRSCUnitConfigConfigurationType
OBJECT-TYPE
The unit configuration type.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.1AirIRSCConfigTyperead-writemandatory
airIRSCUnitConfigCapacityControlType
OBJECT-TYPE
The unit capacity control.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.2AirIRSCCapacityControlTyperead-writemandatory
airIRSCUnitConfigStartupDelay
OBJECT-TYPE
The startup delay in seconds.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.3INTEGERread-writemandatory
airIRSCUnitConfigIdleOnLeakDetect
OBJECT-TYPE
The idle on leak options setting.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.4INTEGER {yes(1), no(2)}read-writemandatory
airIRSCUnitConfigInputNormalState
OBJECT-TYPE
The normal state of the input contact.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.5INTEGER {open(1), closed(2)}read-writemandatory
airIRSCUnitConfigOutputNormalState
OBJECT-TYPE
The normal state of the output relay.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.6INTEGER {open(1), closed(2)}read-writemandatory
airIRSCUnitConfigOutputSource
OBJECT-TYPE
The source of output relay change.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.7INTEGER {anyAlarm(1), criticalAlarm(2)}read-writemandatory
airIRSCUnitConfigAltitudeUS
OBJECT-TYPE
The altitude of the unit above sea level in feet.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.8INTEGERread-writemandatory
airIRSCUnitConfigAltitudeMetric
OBJECT-TYPE
The altitude of the unit above sea level in meters.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.9INTEGERread-writemandatory
airIRSCUnitConfigOpControl
OBJECT-TYPE
The unit operational control.
1.3.6.1.4.1.318.1.1.13.3.4.1.7.10INTEGER {standby(1), on(2)}read-writemandatory
airIRSCGroup
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.2
airIRSCGroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.2.1
airIRSCGroupStatusCoolOutput
OBJECT-TYPE
The group cooling output in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.1INTEGERread-onlymandatory
airIRSCGroupStatusCoolDemand
OBJECT-TYPE
The group cooling demand in tenths of kW.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.2INTEGERread-onlymandatory
airIRSCGroupStatusAirFlowUS
OBJECT-TYPE
The group air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.3INTEGERread-onlymandatory
airIRSCGroupStatusAirFlowMetric
OBJECT-TYPE
The group air flow in liters per second.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.4INTEGERread-onlymandatory
airIRSCGroupStatusMaxRackInletTempUS
OBJECT-TYPE
The group maximum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.5INTEGERread-onlymandatory
airIRSCGroupStatusMaxRackInletTempMetric
OBJECT-TYPE
The group maximum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.6INTEGERread-onlymandatory
airIRSCGroupStatusMinRackInletTempUS
OBJECT-TYPE
The group minimum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.7INTEGERread-onlymandatory
airIRSCGroupStatusMinRackInletTempMetric
OBJECT-TYPE
The group minimum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.8INTEGERread-onlymandatory
airIRSCGroupStatusMaxReturnAirTempUS
OBJECT-TYPE
The group maximum return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.9INTEGERread-onlymandatory
airIRSCGroupStatusMaxReturnAirTempMetric
OBJECT-TYPE
The group maximum return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.10INTEGERread-onlymandatory
airIRSCGroupStatusMinReturnAirTempUS
OBJECT-TYPE
The group minimum return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.11INTEGERread-onlymandatory
airIRSCGroupStatusMinReturnAirTempMetric
OBJECT-TYPE
The group minimum return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.12INTEGERread-onlymandatory
airIRSCGroupStatusActiveFlowControlStatus
OBJECT-TYPE
Status of the active flow control system.
1.3.6.1.4.1.318.1.1.13.3.4.2.1.13INTEGER {under(1), okay(2), over(3), notApplicable(4)}read-onlymandatory
airIRSCGroupSetpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.2.2
airIRSCGroupSetptsCoolSetpointUS
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.1INTEGERread-writemandatory
airIRSCGroupSetptsCoolSetpointMetric
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.2INTEGERread-writemandatory
airIRSCGroupSetptsCoolDeadbandUS
OBJECT-TYPE
Group cooling deadband in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.3INTEGERread-writemandatory
airIRSCGroupSetptsCoolDeadbandMetric
OBJECT-TYPE
Group cooling deadband in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.4INTEGERread-writemandatory
airIRSCGroupSetptsFanSpeedPreference
OBJECT-TYPE
The group preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.5AirIRSCFanSpeedPreferenceread-writemandatory
airIRSCGroupSetptsSupplyAirSetpointUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.6INTEGERread-writemandatory
airIRSCGroupSetptsSupplyAirSetpointMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.7INTEGERread-writemandatory
airIRSCGroupSetpointsActiveFlowControlBias
OBJECT-TYPE
The active flow control bias setting.
1.3.6.1.4.1.318.1.1.13.3.4.2.2.8INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)}read-writemandatory
airIRSCGroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.3.4.2.3
airIRSCGroupConfigNumberofCoolingUnits
OBJECT-TYPE
The number of cooling units.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.1INTEGERread-writemandatory
airIRSCGroupConfigConfigurationType
OBJECT-TYPE
The group configuration type.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.2AirIRSCConfigTyperead-writemandatory
airIRSCGroupConfigCapacityControlType
OBJECT-TYPE
The group capacity control.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.3AirIRSCCapacityControlTyperead-writemandatory
airIRSCGroupConfigAltitudeUS
OBJECT-TYPE
The group altitude of the units above sea level in feet.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.4INTEGERread-writemandatory
airIRSCGroupConfigAltitudeMetric
OBJECT-TYPE
The group altitude of the units above sea level in meters.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.5INTEGERread-writemandatory
airIRSCGroupConfigFanSpeedControl
OBJECT-TYPE
The group fan speed control.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.6AirIRSCFanSpeedControlread-writemandatory
airIRSCGroupConfigNumberOfActiveFlowControllers
OBJECT-TYPE
The number of active flow controllers present in the group.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.7INTEGERread-writemandatory
airIRSCGroupConfigActiveFlowControllerLampTest
OBJECT-TYPE
Turns off/on the active flow controller lamp test.
1.3.6.1.4.1.318.1.1.13.3.4.2.3.8INTEGER {off(1), on(2)}read-writemandatory
airIRGen2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4
airIRG2Ident
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.1
airIRG2IdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.4.1.1DisplayStringread-writemandatory
airIRG2IdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.4.1.2DisplayStringread-writemandatory
airIRG2IdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.4.1.3DisplayStringread-onlymandatory
airIRG2IdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.4.1.4DisplayStringread-onlymandatory
airIRG2IdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.4.1.5DisplayStringread-onlymandatory
airIRG2IdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.4.1.6DisplayStringread-onlymandatory
airIRG2IdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.4.1.7DisplayStringread-onlymandatory
airIRG2IdentUnitSysOID
OBJECT-TYPE
This OID contains an OID path to the device's top level unit data.
1.3.6.1.4.1.318.1.1.13.4.1.8OBJECT IDENTIFIERread-onlymandatory
airIRG2IdentGroupSysOID
OBJECT-TYPE
This OID contains an OID path to the device's top level group data.
1.3.6.1.4.1.318.1.1.13.4.1.9OBJECT IDENTIFIERread-onlymandatory
airIRG2Group
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.2
airIRG2GroupStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.2.1
airIRG2GroupStatusCoolOutput
OBJECT-TYPE
The group cooling output in tenths of kilowatts (kW).
1.3.6.1.4.1.318.1.1.13.4.2.1.1INTEGERread-onlymandatory
airIRG2GroupStatusCoolDemand
OBJECT-TYPE
The group cooling demand in tenths of kilowatts (kW).
1.3.6.1.4.1.318.1.1.13.4.2.1.2INTEGERread-onlymandatory
airIRG2GroupStatusAirFlowUS
OBJECT-TYPE
The group air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.4.2.1.3INTEGERread-onlymandatory
airIRG2GroupStatusAirFlowMetric
OBJECT-TYPE
The group air flow in hundredths of liters per second.
1.3.6.1.4.1.318.1.1.13.4.2.1.4INTEGERread-onlymandatory
airIRG2GroupStatusMaxRackInletTempUS
OBJECT-TYPE
The group maximum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.1.5INTEGERread-onlymandatory
airIRG2GroupStatusMaxRackInletTempMetric
OBJECT-TYPE
The group maximum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.1.6INTEGERread-onlymandatory
airIRG2GroupStatusMinRackInletTempUS
OBJECT-TYPE
The group minimum rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.1.7INTEGERread-onlymandatory
airIRG2GroupStatusMinRackInletTempMetric
OBJECT-TYPE
The group minimum rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.1.8INTEGERread-onlymandatory
airIRG2GroupStatusMaxReturnAirTempUS
OBJECT-TYPE
The group maximum return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.1.9INTEGERread-onlymandatory
airIRG2GroupStatusMaxReturnAirTempMetric
OBJECT-TYPE
The group maximum return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.1.10INTEGERread-onlymandatory
airIRG2GroupStatusMinReturnAirTempUS
OBJECT-TYPE
The group minimum return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.1.11INTEGERread-onlymandatory
airIRG2GroupStatusMinReturnAirTempMetric
OBJECT-TYPE
The group minimum return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.1.12INTEGERread-onlymandatory
airIRG2GroupStatusActiveFlowControlStatus
OBJECT-TYPE
Status of the active flow control system.
1.3.6.1.4.1.318.1.1.13.4.2.1.13INTEGER {under(1), okay(2), over(3), notApplicable(4)}read-onlymandatory
airIRG2GroupSetpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.2.2
airIRG2GroupSetptsCoolSetpointUS
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.2.1INTEGERread-writemandatory
airIRG2GroupSetptsCoolSetpointMetric
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.2.2INTEGERread-writemandatory
airIRG2GroupSetptsCoolDeadbandUS
OBJECT-TYPE
Group cooling deadband in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.2.3INTEGERread-writemandatory
airIRG2GroupSetptsCoolDeadbandMetric
OBJECT-TYPE
Group cooling deadband in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.2.4INTEGERread-writemandatory
airIRG2GroupSetptsFanSpeedPreference
OBJECT-TYPE
The group preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.4.2.2.5INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)}read-writemandatory
airIRG2GroupSetptsSupplyAirSetpointUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.2.2.6INTEGERread-writemandatory
airIRG2GroupSetptsSupplyAirSetpointMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.2.2.7INTEGERread-writemandatory
airIRG2GroupSetpointsActiveFlowControlBias
OBJECT-TYPE
The active flow control bias setting.
1.3.6.1.4.1.318.1.1.13.4.2.2.8INTEGER {positive(1), slightlyPositive(2), zero(3), slightlyNegative(4), negative(5)}read-writemandatory
airIRG2GroupConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.2.3
airIRG2GroupConfigNumberofCoolingUnits
OBJECT-TYPE
The number of cooling units.
1.3.6.1.4.1.318.1.1.13.4.2.3.1INTEGERread-writemandatory
airIRG2GroupConfigConfigurationType
OBJECT-TYPE
The group configuration type.
1.3.6.1.4.1.318.1.1.13.4.2.3.2INTEGER {racs(1), spot(2), in-row(3), hacs(4), cacs(5)}read-writemandatory
airIRG2GroupConfigCapacityControlType
OBJECT-TYPE
The group capacity control.
1.3.6.1.4.1.318.1.1.13.4.2.3.3INTEGER {discrete(1), proportional(2)}read-writemandatory
airIRG2GroupConfigFanSpeedControl
OBJECT-TYPE
The group fan speed control.
1.3.6.1.4.1.318.1.1.13.4.2.3.4INTEGER {automatic(1), manual(2)}read-writemandatory
airIRG2GroupConfigCoolGainP
OBJECT-TYPE
The gain component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.4.2.3.5INTEGERread-writemandatory
airIRG2GroupConfigCoolResetRateI
OBJECT-TYPE
The integral component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.4.2.3.6INTEGERread-writemandatory
airIRG2GroupConfigCoolDerivativeD
OBJECT-TYPE
The derivative component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.4.2.3.7INTEGERread-writemandatory
airIRG2GroupConfigCoolPIDReset
OBJECT-TYPE
Will reset the PID coefficients back to the factory defaults.
1.3.6.1.4.1.318.1.1.13.4.2.3.8INTEGER {readBack(1), reset(2)}read-writemandatory
airIRG2GroupConfigNumberofBackupUnits
OBJECT-TYPE
The number of backup units.
1.3.6.1.4.1.318.1.1.13.4.2.3.9INTEGERread-writemandatory
airIRG2GroupConfigRuntimeBalancingEnable
OBJECT-TYPE
Enable or disable runtime balancing feature.
1.3.6.1.4.1.318.1.1.13.4.2.3.10INTEGER {disable(1), enable(2)}read-writemandatory
airIRG2GroupConfigLoadAssistEnable
OBJECT-TYPE
Enable or disable load assist feature.
1.3.6.1.4.1.318.1.1.13.4.2.3.11INTEGER {disable(1), enable(2)}read-writemandatory
airIRG2GroupConfigNumberOfActiveFlowControllers
OBJECT-TYPE
The number of active flow controllers present in the group.
1.3.6.1.4.1.318.1.1.13.4.2.3.12INTEGERread-writemandatory
airIRG2GroupConfigActiveFlowControllerLampTest
OBJECT-TYPE
Turns off/on the active flow controller lamp test.
1.3.6.1.4.1.318.1.1.13.4.2.3.13INTEGER {off(1), on(2)}read-writemandatory
airIRG2GroupConfigAltitudeUS
OBJECT-TYPE
The group altitude of the units above sea level in feet.
1.3.6.1.4.1.318.1.1.13.4.2.3.14INTEGERread-writemandatory
airIRG2GroupConfigAltitudeMetric
OBJECT-TYPE
The group altitude of the units above sea level in meters.
1.3.6.1.4.1.318.1.1.13.4.2.3.15INTEGERread-writemandatory
airIRG2Alarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.3
airIRG2AlarmsTableSize
OBJECT-TYPE
The number of active alarms in the airIRG2AlarmsTable.
1.3.6.1.4.1.318.1.1.13.4.3.1INTEGERread-onlymandatory
airIRG2AlarmsTable
OBJECT-TYPE
Table of active alarms for the device.
1.3.6.1.4.1.318.1.1.13.4.3.2not-accessiblemandatory
airIRG2AlarmsEntry
OBJECT-TYPE
Alarms specification
1.3.6.1.4.1.318.1.1.13.4.3.2.1not-accessiblemandatory
airIRG2AlarmsIndex
OBJECT-TYPE
Alarm index.
1.3.6.1.4.1.318.1.1.13.4.3.2.1.1INTEGERread-onlymandatory
airIRG2AlarmsEventCode
OBJECT-TYPE
Code for the alarm.
1.3.6.1.4.1.318.1.1.13.4.3.2.1.2INTEGERread-onlymandatory
airIRG2AlarmsDescription
OBJECT-TYPE
Description of the alarm.
1.3.6.1.4.1.318.1.1.13.4.3.2.1.3DisplayString (SIZE(0..64))read-onlymandatory
airIRG2RC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.4
airIRG2RD
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5
airIRG2RDType1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.1
airIRG2RDType2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2
airIRG2RDT2Status
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2.1
airIRG2RDT2StatusOperateMode
OBJECT-TYPE
The cooling unit operating mode.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.1INTEGER {standby(1), on(2), idle(3), reserved(4), service(5)}read-onlymandatory
airIRG2RDT2StatusCoolOutput
OBJECT-TYPE
The unit cooling output in tenths of kilowatts (kW).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.2INTEGERread-onlymandatory
airIRG2RDT2StatusCoolDemand
OBJECT-TYPE
The unit cooling demand in tenths of kilowatts (kW).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.3INTEGERread-onlymandatory
airIRG2RDT2StatusAirFlowUS
OBJECT-TYPE
The unit air flow in cubic feet per minute.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.4INTEGERread-onlymandatory
airIRG2RDT2StatusAirFlowMetric
OBJECT-TYPE
The unit air flow in liters per second.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.5INTEGERread-onlymandatory
airIRG2RDT2StatusRackInletTempUS
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.6INTEGERread-onlymandatory
airIRG2RDT2StatusRackInletTempMetric
OBJECT-TYPE
The unit rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.7INTEGERread-onlymandatory
airIRG2RDT2StatusSupplyAirTempUS
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.8INTEGERread-onlymandatory
airIRG2RDT2StatusSupplyAirTempMetric
OBJECT-TYPE
The unit supply air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.9INTEGERread-onlymandatory
airIRG2RDT2StatusReturnAirTempUS
OBJECT-TYPE
The unit return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.10INTEGERread-onlymandatory
airIRG2RDT2StatusReturnAirTempMetric
OBJECT-TYPE
The unit return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.11INTEGERread-onlymandatory
airIRG2RDT2StatusSuctionTempUS
OBJECT-TYPE
The unit suction temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.12INTEGERread-onlymandatory
airIRG2RDT2StatusSuctionTempMetric
OBJECT-TYPE
The unit suction temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.13INTEGERread-onlymandatory
airIRG2RDT2StatusSuperheatTempUS
OBJECT-TYPE
The unit superheat temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.14INTEGERread-onlymandatory
airIRG2RDT2StatusSuperheatTempMetric
OBJECT-TYPE
The unit superheat temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.15INTEGERread-onlymandatory
airIRG2RDT2StatusFilterDPUS
OBJECT-TYPE
The unit air filter differential pressure in hundredths of inches of water.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.16INTEGERread-onlymandatory
airIRG2RDT2StatusFilterDPMetric
OBJECT-TYPE
The unit air filter differential pressure in pascals (Pa).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.17INTEGERread-onlymandatory
airIRG2RDT2StatusSuctionPressureUS
OBJECT-TYPE
Unit suction pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.18INTEGERread-onlymandatory
airIRG2RDT2StatusSuctionPressureMetric
OBJECT-TYPE
Unit suction pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.19INTEGERread-onlymandatory
airIRG2RDT2StatusDischargePressureUS
OBJECT-TYPE
Unit discharge pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.20INTEGERread-onlymandatory
airIRG2RDT2StatusDischargePressureMetric
OBJECT-TYPE
Unit discharge pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.21INTEGERread-onlymandatory
airIRG2RDT2StatusEvaporatorFanSpeed
OBJECT-TYPE
The unit average evaporator fan speed in tenths of percent.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.22INTEGERread-onlymandatory
airIRG2RDT2StatusInputState
OBJECT-TYPE
The state of the input contact.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.23AirIRG2RDType2IOStateread-onlymandatory
airIRG2RDT2StatusOutputState
OBJECT-TYPE
The state of the output relay.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.24AirIRG2RDType2IOStateread-onlymandatory
airIRG2RDT2StatusOHEInputState
OBJECT-TYPE
The state of the outside heat exchanger(OHE) input contact.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.25AirIRG2RDType2IOStateread-onlymandatory
airIRG2RDT2StatusOHEOutputState
OBJECT-TYPE
The state of the outside heat exchanger(OHE) output relay.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.26AirIRG2RDType2IOStateread-onlymandatory
airIRG2RDT2StatusCompressor
OBJECT-TYPE
The state (off/on) of the compressor.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.27INTEGER {off(1), on(2)}read-onlymandatory
airIRG2RDT2StatusFluidValvePos
OBJECT-TYPE
The position of the fluid valve in percent. This OID is only valid when airIRG2RDT2ConfigUnitType indicates fluidCooled(1).
1.3.6.1.4.1.318.1.1.13.4.5.2.1.28INTEGERread-onlymandatory
airIRG2RDT2StatusHotGasBypassValvePos
OBJECT-TYPE
The position of the hot gas bypass valve in hundredths of percent.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.29INTEGERread-onlymandatory
airIRG2RDT2StatusLeakSensor
OBJECT-TYPE
The state (no-leak/leak) of the leak sensor.
1.3.6.1.4.1.318.1.1.13.4.5.2.1.30INTEGER {no-leak(1), leak(2)}read-onlymandatory
airIRG2RDT2RunHours
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2.2
airIRG2RDT2RunHoursAirFilter
OBJECT-TYPE
Unit air filter run hours.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.1INTEGERread-onlymandatory
airIRG2RDT2RunHoursCondensatePump
OBJECT-TYPE
Unit condensate pump run hours.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.2INTEGERread-onlymandatory
airIRG2RDT2RunHoursCompressor
OBJECT-TYPE
Unit compressor run hours.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.3INTEGERread-onlymandatory
airIRG2RDT2RunHoursFanPSTableSize
OBJECT-TYPE
The number of entries in the run hour fan power supply table (airIRG2RDT2RunHoursFanPSTable).
1.3.6.1.4.1.318.1.1.13.4.5.2.2.4INTEGERread-onlymandatory
airIRG2RDT2RunHoursFanPSTable
OBJECT-TYPE
Allows for getting run hour information from each power supply.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.5not-accessiblemandatory
airIRG2RDT2RunHoursFanPSEntry
OBJECT-TYPE
The run hours fan power supply table entry.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1not-accessiblemandatory
airIRG2RDT2RunHoursFanPSIndex
OBJECT-TYPE
Index of run hours fan power supply table.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.1INTEGERread-onlymandatory
airIRG2RDT2RunHoursFanPSHours
OBJECT-TYPE
Fan power supply run time in hours.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.2INTEGERread-onlymandatory
airIRG2RDT2RunHoursFanPSPosition
OBJECT-TYPE
Position of fan power supply within the unit.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.3INTEGER {upper(1), lower(2), left(3), right(4)}read-onlymandatory
airIRG2RDT2RunHoursEvapFanTableSize
OBJECT-TYPE
The number of entries in the run hour evaporator fan table (airIRG2RDT2RunHoursEvapFanTable).
1.3.6.1.4.1.318.1.1.13.4.5.2.2.6INTEGERread-onlymandatory
airIRG2RDT2RunHoursEvapFanTable
OBJECT-TYPE
Allows for getting information from each evaporator fan run hour in the system.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.7not-accessiblemandatory
airIRG2RDT2RunHoursEvapFanEntry
OBJECT-TYPE
Allows for getting information from each evaporator fan run hour in the system.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1not-accessiblemandatory
airIRG2RDT2RunHoursEvapFanIndex
OBJECT-TYPE
Index of run hours evaporator fan table.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.1INTEGERread-onlymandatory
airIRG2RDT2RunHoursEvapFanHours
OBJECT-TYPE
Evaporator fan run time in hours.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.2INTEGERread-onlymandatory
airIRG2RDT2RunHoursUnit
OBJECT-TYPE
Unit run time in hours.
1.3.6.1.4.1.318.1.1.13.4.5.2.2.8INTEGERread-onlymandatory
airIRG2RDT2ServiceIntervals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2.3
airIRG2RDT2ServiceIntervalsAirFilter
OBJECT-TYPE
Air filter service interval in weeks.
1.3.6.1.4.1.318.1.1.13.4.5.2.3.1INTEGERread-writemandatory
airIRG2RDT2ServiceIntervalsAirFilterAlarm
OBJECT-TYPE
The air filter service interval alarm enable/disable.
1.3.6.1.4.1.318.1.1.13.4.5.2.3.2INTEGER {enable(1), disable(2)}read-writemandatory
airIRG2RDT2Thresholds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2.4
airIRG2RDT2ThresholdsRackInletHighTempUS
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.4.1INTEGERread-writemandatory
airIRG2RDT2ThresholdsRackInletHighTempMetric
OBJECT-TYPE
Unit rack inlet air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.4.2INTEGERread-writemandatory
airIRG2RDT2ThresholdsSupplyAirHighTempUS
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.4.3INTEGERread-writemandatory
airIRG2RDT2ThresholdsSupplyAirHighTempMetric
OBJECT-TYPE
Unit supply air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.4.4INTEGERread-writemandatory
airIRG2RDT2ThresholdsReturnAirHighTempUS
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.4.5.2.4.5INTEGERread-writemandatory
airIRG2RDT2ThresholdsReturnAirHighTempMetric
OBJECT-TYPE
Unit return air high temperature threshold in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.4.5.2.4.6INTEGERread-writemandatory
airIRG2RDT2Setpoints
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2.5
airIRG2RDT2Config
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.5.2.6
airIRG2RDT2ConfigUnitType
OBJECT-TYPE
The type of the unit.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.1INTEGER {fluidCooled(1), airCooled(2)}read-onlymandatory
airIRG2RDT2ConfigStartupDelay
OBJECT-TYPE
The startup delay in seconds.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.2INTEGERread-writemandatory
airIRG2RDT2ConfigIdleOnLeakDetect
OBJECT-TYPE
The idle on leak options setting.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.3INTEGER {yes(1), no(2)}read-writemandatory
airIRG2RDT2ConfigInputNormalState
OBJECT-TYPE
The normal state of the input contact.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.4AirIRG2RDType2IOStateread-writemandatory
airIRG2RDT2ConfigOutputNormalState
OBJECT-TYPE
The normal state of the output relay.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.5AirIRG2RDType2IOStateread-writemandatory
airIRG2RDT2ConfigOutputSource
OBJECT-TYPE
The source of output relay change.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.6INTEGER {anyAlarm(1), criticalAlarm(2)}read-writemandatory
airIRG2RDT2ConfigOHEInputNormalState
OBJECT-TYPE
The normal state of the outside heat exchanger(OHE) input relay.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.7AirIRG2RDType2IOStateread-writemandatory
airIRG2RDT2ConfigUnitRoleOverride
OBJECT-TYPE
When this OID value is (1) automatic, the system determines which units are used as primary units and which units are used as backups. When this OID value is (2) forcedOn, the connected unit is set as a primary unit.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.8INTEGER {automatic(1), forcedOn(2)}read-writemandatory
airIRG2RDT2ConfigUnitIdleOnCoolFail
OBJECT-TYPE
When this OID value is (2) yes, the unit idles if it detects that it is blowing warm air into the cold aisle. The unit will attempt to restart at 5 minute intervals.
1.3.6.1.4.1.318.1.1.13.4.5.2.6.9INTEGER {no(1), yes(2)}read-writemandatory
airIRG2SC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.6
airIRG2RA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.4.7
airInRoom
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5
airIRmIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.1
airIRmIdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.5.1.1DisplayStringread-writemandatory
airIRmIdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.5.1.2DisplayStringread-writemandatory
airIRmIdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.5.1.3DisplayStringread-onlymandatory
airIRmIdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.5.1.4DisplayStringread-onlymandatory
airIRmIdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.5.1.5DisplayStringread-onlymandatory
airIRmIdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.5.1.6DisplayStringread-onlymandatory
airIRmIdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.5.1.7DisplayStringread-onlymandatory
airIRmIdentSysOID
OBJECT-TYPE
This OID contains an OID path to the device's top level data.
1.3.6.1.4.1.318.1.1.13.5.1.8OBJECT IDENTIFIERread-onlymandatory
airIRmAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.2
airIRmAlarmsTableSize
OBJECT-TYPE
The number of active alarms in the airIRG2AlarmsTable.
1.3.6.1.4.1.318.1.1.13.5.2.1INTEGERread-onlymandatory
airIRmAlarmsTable
OBJECT-TYPE
Table of active alarms for the device.
1.3.6.1.4.1.318.1.1.13.5.2.2not-accessiblemandatory
airIRmAlarmsEntry
OBJECT-TYPE
Alarms specification
1.3.6.1.4.1.318.1.1.13.5.2.2.1not-accessiblemandatory
airIRmAlarmsIndex
OBJECT-TYPE
Alarm index.
1.3.6.1.4.1.318.1.1.13.5.2.2.1.1INTEGERread-onlymandatory
airIRmAlarmsEventCode
OBJECT-TYPE
Code for the alarm.
1.3.6.1.4.1.318.1.1.13.5.2.2.1.2INTEGERread-onlymandatory
airIRmAlarmsDescription
OBJECT-TYPE
Description of the alarm.
1.3.6.1.4.1.318.1.1.13.5.2.2.1.3DisplayString (SIZE(0..64))read-onlymandatory
airIRmPerimeter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3
airIRmPmCommon1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.2
airIRmPmUnitType
OBJECT-TYPE
Unit type (1).
1.3.6.1.4.1.318.1.1.13.5.3.2.1INTEGER {mc(1), dx(2), cw(3), ch(4), ecoCool(5), msc(6), ge1(7), ge2(8), dualFluid(9), cw2(10), unknown(256)}read-onlymandatory
airIRmPmSwVersion
OBJECT-TYPE
Software version (3).
1.3.6.1.4.1.318.1.1.13.5.3.2.3DisplayStringread-onlymandatory
airIRmPmBusAddress
OBJECT-TYPE
Bus addresss of unit (5).
1.3.6.1.4.1.318.1.1.13.5.3.2.5INTEGER (0..65535)read-onlymandatory
airIRmPmControllerType
OBJECT-TYPE
Controller type (7).
1.3.6.1.4.1.318.1.1.13.5.3.2.7INTEGER {unknown(1), c4000(2), c1001(3), c1002(4), c5000(5), c6000(6), c1010(7), c7000IOC(8), c7000AT(9), c7000PT(10), c5MSC(11), c7000PT2(12)}read-onlymandatory
airIRmPmGeneralError
OBJECT-TYPE
General Error (8)
1.3.6.1.4.1.318.1.1.13.5.3.2.8AirIRmAlarmStateread-onlymandatory
airIRmPmErrorOnBus
OBJECT-TYPE
Error On Bus (9)
1.3.6.1.4.1.318.1.1.13.5.3.2.9AirIRmAlarmStateread-onlymandatory
airIRmPmCommon2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.3
airIRmPmPCStop
OBJECT-TYPE
PC-STOP (1000)
1.3.6.1.4.1.318.1.1.13.5.3.3.1AirIRmStopStateread-onlymandatory
airIRmPmRemoteStop
OBJECT-TYPE
Remote Stop (1001)
1.3.6.1.4.1.318.1.1.13.5.3.3.2AirIRmStopStateread-onlymandatory
airIRmPmLocalStop
OBJECT-TYPE
Local Stop (1002)
1.3.6.1.4.1.318.1.1.13.5.3.3.3AirIRmStopStateread-onlymandatory
airIRmPmTimerStop
OBJECT-TYPE
Timer Stop (1003)
1.3.6.1.4.1.318.1.1.13.5.3.3.4AirIRmStopStateread-onlymandatory
airIRmPmSeqStop
OBJECT-TYPE
Seq. Stop (1004)
1.3.6.1.4.1.318.1.1.13.5.3.3.5AirIRmStopStateread-onlymandatory
airIRmPmRemoteUPS
OBJECT-TYPE
Remote UPS (1006)
1.3.6.1.4.1.318.1.1.13.5.3.3.7INTEGER {off(1), on(2)}read-onlymandatory
airIRmPmLocalUPS
OBJECT-TYPE
Local UPS (1007)
1.3.6.1.4.1.318.1.1.13.5.3.3.8AirIRmActivityStateread-onlymandatory
airIRmPmCommonAlarm
OBJECT-TYPE
Common alarm (1010).
1.3.6.1.4.1.318.1.1.13.5.3.3.11AirIRmAlarmStateread-onlymandatory
airIRmPmResetAllAlarms
OBJECT-TYPE
Reset all alarms control (1011).
1.3.6.1.4.1.318.1.1.13.5.3.3.12INTEGER {doNothing(1), reset(2)}read-writemandatory
airIRmPmUnitOnOff
OBJECT-TYPE
Unit running state (1013).
1.3.6.1.4.1.318.1.1.13.5.3.3.14AirIRmControlStateread-onlymandatory
airIRmPmMaintenance
OBJECT-TYPE
Maintenance necessary state (1014).
1.3.6.1.4.1.318.1.1.13.5.3.3.15INTEGER {notNecessary(1), necessary(2)}read-onlymandatory
airIRmPmUnitTemperatureScale
OBJECT-TYPE
Current Unit Temperature Scale (1022).
1.3.6.1.4.1.318.1.1.13.5.3.3.23INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
airIRmPmUnitWinterMode
OBJECT-TYPE
Winter or summer configuration mode (1023).
1.3.6.1.4.1.318.1.1.13.5.3.3.24INTEGER {summer(1), winter(2)}read-onlymandatory
airIRmPmDayNightMode
OBJECT-TYPE
Day or night configuration mode (1024).
1.3.6.1.4.1.318.1.1.13.5.3.3.25INTEGER {day(1), night(2)}read-onlymandatory
airIRmPmCommon3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4
airIRmPmLastMaintenanceYear
OBJECT-TYPE
Last maintenance year (1160).
1.3.6.1.4.1.318.1.1.13.5.3.4.1INTEGERread-onlymandatory
airIRmPmLastMaintenanceMonth
OBJECT-TYPE
Last maintenance month (1161).
1.3.6.1.4.1.318.1.1.13.5.3.4.2INTEGER (1..12)read-onlymandatory
airIRmPmLastMaintenanceDay
OBJECT-TYPE
Last maintenance day (1162).
1.3.6.1.4.1.318.1.1.13.5.3.4.3INTEGER (1..31)read-onlymandatory
airIRmPmUnitMaintenanceInterval
OBJECT-TYPE
Unit maintenance interval in months (1163).
1.3.6.1.4.1.318.1.1.13.5.3.4.4INTEGER (1..255)read-onlymandatory
airIRmPmRuntimeUnit
OBJECT-TYPE
Runtime unit in hours (1164).
1.3.6.1.4.1.318.1.1.13.5.3.4.5INTEGERread-onlymandatory
airIRmPmStoptimeUnit
OBJECT-TYPE
Unit stoptime in hours (1165)
1.3.6.1.4.1.318.1.1.13.5.3.4.6INTEGERread-onlymandatory
airIRmPmRuntimeCooling
OBJECT-TYPE
Cooling runtime in hours (1166)
1.3.6.1.4.1.318.1.1.13.5.3.4.7INTEGERread-onlymandatory
airIRmPmRuntimeHeating
OBJECT-TYPE
Heating runtime in hours (1167)
1.3.6.1.4.1.318.1.1.13.5.3.4.8INTEGERread-onlymandatory
airIRmPmRuntimeHumidification
OBJECT-TYPE
Humidification runtime in hours (1168)
1.3.6.1.4.1.318.1.1.13.5.3.4.9INTEGERread-onlymandatory
airIRmPmRuntimeDehumidification
OBJECT-TYPE
Dehumidification runtime in hours (1169)
1.3.6.1.4.1.318.1.1.13.5.3.4.10INTEGERread-onlymandatory
airIRmPmUnitTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.11
airIRmPmUnitTemperatureC
OBJECT-TYPE
Unit temperature in tenths of degrees Celsius (1170).
1.3.6.1.4.1.318.1.1.13.5.3.4.11.1INTEGERread-onlymandatory
airIRmPmUnitTemperatureF
OBJECT-TYPE
Unit temperature in tenths of degrees Fahrenheit (1170).
1.3.6.1.4.1.318.1.1.13.5.3.4.11.2INTEGERread-onlymandatory
airIRmPmUnitHumidity
OBJECT-TYPE
Unit humidity in tenths of %RH (1171).
1.3.6.1.4.1.318.1.1.13.5.3.4.12INTEGERread-onlymandatory
airIRmPmSetpointTemperatureDay
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.14
airIRmPmSetpointTemperatureDayC
OBJECT-TYPE
Setpoint daytime temperature in tenths of degrees Celsius (1173).
1.3.6.1.4.1.318.1.1.13.5.3.4.14.1INTEGERread-writemandatory
airIRmPmSetpointTemperatureDayF
OBJECT-TYPE
Setpoint daytime temperature in tenths of degrees Fahrenheit (1173).
1.3.6.1.4.1.318.1.1.13.5.3.4.14.2INTEGERread-writemandatory
airIRmPmSetpointTemperatureNight
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.15
airIRmPmSetpointTemperatureNightC
OBJECT-TYPE
Setpoint nighttime temperature in tenths of degrees Celsius (1174).
1.3.6.1.4.1.318.1.1.13.5.3.4.15.1INTEGERread-writemandatory
airIRmPmSetpointTemperatureNightF
OBJECT-TYPE
Setpoint nighttime temperature in tenths of degrees Fahrenheit (1174).
1.3.6.1.4.1.318.1.1.13.5.3.4.15.2INTEGERread-writemandatory
airIRmPmSetpointHumidity
OBJECT-TYPE
Setpoint humidity in tenths of %RH (1176).
1.3.6.1.4.1.318.1.1.13.5.3.4.17INTEGERread-writemandatory
airIRmPmUnitControlType
OBJECT-TYPE
Current unit control type (1183).
1.3.6.1.4.1.318.1.1.13.5.3.4.24INTEGER {room(1), supply(2), room-SupplyLimit(3), supply-RoomLimit(4)}read-onlymandatory
airIRmPmWinterModeStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.29
airIRmPmWinterModeStartTempC
OBJECT-TYPE
Winter mode start temperature in tenths of degrees Celsius (1188).
1.3.6.1.4.1.318.1.1.13.5.3.4.29.1INTEGERread-onlymandatory
airIRmPmWinterModeStartTempF
OBJECT-TYPE
Winter mode start temperature in tenths of degrees Fahrenheit (1188).
1.3.6.1.4.1.318.1.1.13.5.3.4.29.2INTEGERread-onlymandatory
airIRmPmWinterModeHysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.30
airIRmPmWinterModeHysteresisK
OBJECT-TYPE
Winter mode hysteresis in tenths of Kelvins (1189)
1.3.6.1.4.1.318.1.1.13.5.3.4.30.1INTEGERread-onlymandatory
airIRmPmWinterModeHysteresisF
OBJECT-TYPE
Winter mode hysteresis in tenths of degrees Fahrenheit (1189)
1.3.6.1.4.1.318.1.1.13.5.3.4.30.2INTEGERread-onlymandatory
airIRmPmWaterTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.32
airIRmPmWaterTemperatureC
OBJECT-TYPE
Water temperature in tenths of degrees Celsius (1191).
1.3.6.1.4.1.318.1.1.13.5.3.4.32.1INTEGERread-onlymandatory
airIRmPmWaterTemperatureF
OBJECT-TYPE
Water temperature in tenths of degrees Fahrenheit (1191).
1.3.6.1.4.1.318.1.1.13.5.3.4.32.2INTEGERread-onlymandatory
airIRmPmReturnAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.33
airIRmPmReturnAirTemperatureC
OBJECT-TYPE
Return air temperature in tenths of degrees Celsius (1192).
1.3.6.1.4.1.318.1.1.13.5.3.4.33.1INTEGERread-onlymandatory
airIRmPmReturnAirTemperatureF
OBJECT-TYPE
Return air temperature in tenths of degrees Fahrenheit (1192).
1.3.6.1.4.1.318.1.1.13.5.3.4.33.2INTEGERread-onlymandatory
airIRmPmSupplyAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.34
airIRmPmSupplyAirTemperatureC
OBJECT-TYPE
Supply air temperature in tenths of degrees Celsius (1193).
1.3.6.1.4.1.318.1.1.13.5.3.4.34.1INTEGERread-onlymandatory
airIRmPmSupplyAirTemperatureF
OBJECT-TYPE
Supply air temperature in tenths of degrees Fahrenheit (1193).
1.3.6.1.4.1.318.1.1.13.5.3.4.34.2INTEGERread-onlymandatory
airIRmPmReturnAirHumidity
OBJECT-TYPE
Return air humidity in tenths of %RH (1194).
1.3.6.1.4.1.318.1.1.13.5.3.4.35INTEGERread-onlymandatory
airIRmPmSupplyAirHumidity
OBJECT-TYPE
Supply air humidity in tenths of %RH (1195).
1.3.6.1.4.1.318.1.1.13.5.3.4.36INTEGERread-onlymandatory
airIRmPmOutsideAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.37
airIRmPmOutsideAirTemperatureC
OBJECT-TYPE
Outside air temperature in tenths of degrees Celsius (1196)
1.3.6.1.4.1.318.1.1.13.5.3.4.37.1INTEGERread-onlymandatory
airIRmPmOutsideAirTemperatureF
OBJECT-TYPE
Outside air temperature in tenths of degrees Fahrenheit (1196)
1.3.6.1.4.1.318.1.1.13.5.3.4.37.2INTEGERread-onlymandatory
airIRmPmOutsideAirHumidity
OBJECT-TYPE
Outside air humidity in tenths of percent relative humidity (1197)
1.3.6.1.4.1.318.1.1.13.5.3.4.38INTEGERread-onlymandatory
airIRmPmCoolingPriority
OBJECT-TYPE
Cooling priority (1198).
1.3.6.1.4.1.318.1.1.13.5.3.4.39INTEGER {ge(1), cw(2), dx(3)}read-writemandatory
airIRmPmWaterTemperature2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.4.43
airIRmPmWaterTemperature2C
OBJECT-TYPE
Water temperature 2 in tenths of degrees Celsius (1202).
1.3.6.1.4.1.318.1.1.13.5.3.4.43.1INTEGERread-onlymandatory
airIRmPmWaterTemperature2F
OBJECT-TYPE
Water temperature 2 in tenths of degrees Fahrenheit (1202).
1.3.6.1.4.1.318.1.1.13.5.3.4.43.2INTEGERread-onlymandatory
airIRmPmRuntimeFreeCooling
OBJECT-TYPE
Freecooling runtime in hours (1203)
1.3.6.1.4.1.318.1.1.13.5.3.4.44INTEGERread-onlymandatory
airIRmPmRuntimeMixedModeFreeCooling
OBJECT-TYPE
Mixed mode freecooling runtime in hours (1203)
1.3.6.1.4.1.318.1.1.13.5.3.4.45INTEGERread-onlymandatory
airIRmPmCommon4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.5
airIRmPmNumberOfCompressors
OBJECT-TYPE
Number of compressors (1761)
1.3.6.1.4.1.318.1.1.13.5.3.5.4INTEGERread-onlymandatory
airIRmPmNumberOfSuctionValves
OBJECT-TYPE
Number of suction valves (1762)
1.3.6.1.4.1.318.1.1.13.5.3.5.5INTEGERread-onlymandatory
airIRmPmNumberOfDryCoolers
OBJECT-TYPE
Number of drycoolers (1763)
1.3.6.1.4.1.318.1.1.13.5.3.5.6INTEGERread-onlymandatory
airIRmPmNumberOfPumps
OBJECT-TYPE
Number of pumps (1764)
1.3.6.1.4.1.318.1.1.13.5.3.5.7INTEGERread-onlymandatory
airIRmPmNumberOfElectricHeaters
OBJECT-TYPE
Number of electric heaters (1765)
1.3.6.1.4.1.318.1.1.13.5.3.5.8INTEGERread-onlymandatory
airIRmPmNumberOfHumidifiers
OBJECT-TYPE
Number of humidifiers (1766)
1.3.6.1.4.1.318.1.1.13.5.3.5.9INTEGERread-onlymandatory
airIRmPmNumberOfFans
OBJECT-TYPE
Number of fans (1767)
1.3.6.1.4.1.318.1.1.13.5.3.5.10INTEGERread-onlymandatory
airIRmPmNumberOfLouvers
OBJECT-TYPE
Number of louvers (1768)
1.3.6.1.4.1.318.1.1.13.5.3.5.11INTEGERread-onlymandatory
airIRmPmNumberOfSensors
OBJECT-TYPE
Number of sensors (1769)
1.3.6.1.4.1.318.1.1.13.5.3.5.12INTEGERread-onlymandatory
airIRmPmNumberOfExternalAlarmInputs
OBJECT-TYPE
Number of external alarm inputs (1770)
1.3.6.1.4.1.318.1.1.13.5.3.5.13INTEGERread-onlymandatory
airIRmPmNumberOfGECWValves
OBJECT-TYPE
Number of GE/CW valves (1771)
1.3.6.1.4.1.318.1.1.13.5.3.5.14INTEGERread-onlymandatory
airIRmPmNumberOfHotGasReheat
OBJECT-TYPE
Number of hot gas reheaters (1772)
1.3.6.1.4.1.318.1.1.13.5.3.5.15INTEGERread-onlymandatory
airIRmPmNumberOfPWWReheat
OBJECT-TYPE
Number of PWW reheaters (1773)
1.3.6.1.4.1.318.1.1.13.5.3.5.16INTEGERread-onlymandatory
airIRmPmNumberOfDehumidifiers
OBJECT-TYPE
Number of dehumidifiers (1774)
1.3.6.1.4.1.318.1.1.13.5.3.5.17INTEGERread-onlymandatory
airIRmPmCommon5
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6
airIRmPmUnitEvaporationTemperature1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.1
airIRmPmUnitEvaporationTemperature1C
OBJECT-TYPE
Unit evaporation temperature 1 in tenths of degrees Celsius (2232)
1.3.6.1.4.1.318.1.1.13.5.3.6.1.1INTEGERread-onlymandatory
airIRmPmUnitEvaporationTemperature1F
OBJECT-TYPE
Unit evaporation temperature 1 in tenths of degrees Fahrenheit (2232)
1.3.6.1.4.1.318.1.1.13.5.3.6.1.2INTEGERread-onlymandatory
airIRmPmUnitEvaporationPressure1
OBJECT-TYPE
Unit evaporation pressure 1 in tenths of Bars (2233)
1.3.6.1.4.1.318.1.1.13.5.3.6.2INTEGERread-onlymandatory
airIRmPmUnitCondensationTemperature1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.3
airIRmPmUnitCondensationTemperature1C
OBJECT-TYPE
Unit condensation temperature 1 in tenths of degrees Celsius (2234)
1.3.6.1.4.1.318.1.1.13.5.3.6.3.1INTEGERread-onlymandatory
airIRmPmUnitCondensationTemperature1F
OBJECT-TYPE
Unit condensation temperature 1 in tenths of degrees Fahrenheit (2234)
1.3.6.1.4.1.318.1.1.13.5.3.6.3.2INTEGERread-onlymandatory
airIRmPmUnitCondensationPressure1
OBJECT-TYPE
Unit condensation pressure 1 in tenths of Bars (2235)
1.3.6.1.4.1.318.1.1.13.5.3.6.4INTEGERread-onlymandatory
airIRmPmMaxLimitReturnAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.8
airIRmPmMaxLimitReturnAirTemperatureC
OBJECT-TYPE
Maximum limit return air temperature in tenths of degrees Celsius (2239).
1.3.6.1.4.1.318.1.1.13.5.3.6.8.1INTEGERread-writemandatory
airIRmPmMaxLimitReturnAirTemperatureF
OBJECT-TYPE
Maximum limit return air temperature in tenths of degrees Fahrenheit (2239).
1.3.6.1.4.1.318.1.1.13.5.3.6.8.2INTEGERread-writemandatory
airIRmPmMinLimitReturnAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.9
airIRmPmMinLimitReturnAirTemperatureC
OBJECT-TYPE
Minimum limit return air temperature in tenths of degrees Celsius (2240).
1.3.6.1.4.1.318.1.1.13.5.3.6.9.1INTEGERread-writemandatory
airIRmPmMinLimitReturnAirTemperatureF
OBJECT-TYPE
Minimum limit return air temperature in tenths of degrees Fahrenheit (2240).
1.3.6.1.4.1.318.1.1.13.5.3.6.9.2INTEGERread-writemandatory
airIRmPmMaxLimitSupplyAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.10
airIRmPmMaxLimitSupplyAirTemperatureC
OBJECT-TYPE
Maximum limit supply air temperature in tenths of degrees Celsius (2241).
1.3.6.1.4.1.318.1.1.13.5.3.6.10.1INTEGERread-writemandatory
airIRmPmMaxLimitSupplyAirTemperatureF
OBJECT-TYPE
Maximum limit supply air temperature in tenths of degrees Fahrenheit (2241).
1.3.6.1.4.1.318.1.1.13.5.3.6.10.2INTEGERread-writemandatory
airIRmPmMinLimitSupplyAirTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.11
airIRmPmMinLimitSupplyAirTemperatureC
OBJECT-TYPE
Minimum limit supply air temperature in tenths of degrees Celsius (2242).
1.3.6.1.4.1.318.1.1.13.5.3.6.11.1INTEGERread-writemandatory
airIRmPmMinLimitSupplyAirTemperatureF
OBJECT-TYPE
Minimum limit supply air temperature in tenths of degrees Fahrenheit (2242).
1.3.6.1.4.1.318.1.1.13.5.3.6.11.2INTEGERread-writemandatory
airIRmPmMaxLimitWaterTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.12
airIRmPmMaxLimitWaterTemperatureC
OBJECT-TYPE
Maximum limit water temperature in tenths of degrees Celsius (2243).
1.3.6.1.4.1.318.1.1.13.5.3.6.12.1INTEGERread-writemandatory
airIRmPmMaxLimitWaterTemperatureF
OBJECT-TYPE
Maximum limit water temperature in tenths of degrees Fahrenheit (2243).
1.3.6.1.4.1.318.1.1.13.5.3.6.12.2INTEGERread-writemandatory
airIRmPmMinLimitWaterTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.13
airIRmPmMinLimitWaterTemperatureC
OBJECT-TYPE
Minimum limit water temperature in tenths of degrees Celsius (2244).
1.3.6.1.4.1.318.1.1.13.5.3.6.13.1INTEGERread-writemandatory
airIRmPmMinLimitWaterTemperatureF
OBJECT-TYPE
Minimum limit water temperature in tenths of degrees Fahrenheit (2244).
1.3.6.1.4.1.318.1.1.13.5.3.6.13.2INTEGERread-writemandatory
airIRmPmMaxLimitReturnAirHumidity
OBJECT-TYPE
Maximum limit return air humidity in tenths of %RH (2245).
1.3.6.1.4.1.318.1.1.13.5.3.6.14INTEGERread-writemandatory
airIRmPmMinLimitReturnAirHumidity
OBJECT-TYPE
Minimum limit return air humidity in tenths of %RH (2246).
1.3.6.1.4.1.318.1.1.13.5.3.6.15INTEGERread-writemandatory
airIRmPmMaxLimitSupplyAirHumidity
OBJECT-TYPE
Maximum limit supply air humidity in tenths of %RH (2247).
1.3.6.1.4.1.318.1.1.13.5.3.6.16INTEGERread-writemandatory
airIRmPmMinLimitSupplyAirHumidity
OBJECT-TYPE
Minimum limit supply air humidity in tenths of %RH (2248).
1.3.6.1.4.1.318.1.1.13.5.3.6.17INTEGERread-writemandatory
airIRmPmLowPressureWinterDelay
OBJECT-TYPE
Winter mode low pressure delay in seconds (2249)
1.3.6.1.4.1.318.1.1.13.5.3.6.18INTEGERread-onlymandatory
airIRmPmUnitCondensationPressure2
OBJECT-TYPE
Unit condensation pressure 2 in tenths of Bars (2250)
1.3.6.1.4.1.318.1.1.13.5.3.6.19INTEGERread-onlymandatory
airIRmPmUnitOverloadSwitch
OBJECT-TYPE
Unit overload switch setting in tenths of Kelvins (2251)
1.3.6.1.4.1.318.1.1.13.5.3.6.20INTEGERread-onlymandatory
airIRmPmUnitCondensationTemperature2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.41
airIRmPmUnitCondensationTemperature2C
OBJECT-TYPE
Unit condensation temperature 2 in tenths of degrees Celsius (2272)
1.3.6.1.4.1.318.1.1.13.5.3.6.41.1INTEGERread-onlymandatory
airIRmPmUnitCondensationTemperature2F
OBJECT-TYPE
Unit condensation temperature 2 in tenths of degrees Fahrenheit (2272)
1.3.6.1.4.1.318.1.1.13.5.3.6.41.2INTEGERread-onlymandatory
airIRmPmUnitEvaporationPressure2
OBJECT-TYPE
Unit evaporation pressure 2 in tenths of Bars (2273)
1.3.6.1.4.1.318.1.1.13.5.3.6.42INTEGERread-onlymandatory
airIRmPmUnitEvaporationTemperature2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.6.43
airIRmPmUnitEvaporationTemperature2C
OBJECT-TYPE
Unit evaporation temperature 2 in tenths of degrees Celsius (2274)
1.3.6.1.4.1.318.1.1.13.5.3.6.43.1INTEGERread-onlymandatory
airIRmPmUnitEvaporationTemperature2F
OBJECT-TYPE
Unit evaporation temperature 2 in tenths of degrees Fahrenheit (2274)
1.3.6.1.4.1.318.1.1.13.5.3.6.43.2INTEGERread-onlymandatory
airIRmPmCompressor1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.7
airIRmPmCmp1ManOperationActive
OBJECT-TYPE
Compressor 1 manual operation active (4401)
1.3.6.1.4.1.318.1.1.13.5.3.7.2INTEGER {automatic(1), manual(2)}read-onlymandatory
airIRmPmCmp1ManOperationState
OBJECT-TYPE
Compressor 1 manual operation state (4402)
1.3.6.1.4.1.318.1.1.13.5.3.7.3AirIRmControlStateread-onlymandatory
airIRmPmCmp1Running
OBJECT-TYPE
Compressor 1 running (4403)
1.3.6.1.4.1.318.1.1.13.5.3.7.4AirIRmActivityStateread-onlymandatory
airIRmPmCmp1StartTempSummer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.7.17
airIRmPmCmp1StartTempSummerK
OBJECT-TYPE
Compressor 1 summer mode start temperature in tenths of Kelvins (4416)
1.3.6.1.4.1.318.1.1.13.5.3.7.17.1INTEGERread-writemandatory
airIRmPmCmp1StartTempSummerF
OBJECT-TYPE
Compressor 1 summer mode start temperature in tenths of degrees Fahrenheit (4416)
1.3.6.1.4.1.318.1.1.13.5.3.7.17.2INTEGERread-writemandatory
airIRmPmCmp1HysteresisSummer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.7.18
airIRmPmCmp1HysteresisSummerK
OBJECT-TYPE
Compressor 1 summer mode hysteresis setting in tenths of Kelvins (4417)
1.3.6.1.4.1.318.1.1.13.5.3.7.18.1INTEGERread-writemandatory
airIRmPmCmp1HysteresisSummerF
OBJECT-TYPE
Compressor 1 summer mode hysteresis setting in tenths of Fahrenheit (4417)
1.3.6.1.4.1.318.1.1.13.5.3.7.18.2INTEGERread-writemandatory
airIRmPmCmp1StartTempWinter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.7.19
airIRmPmCmp1StartTempWinterK
OBJECT-TYPE
Compressor 1 winter mode start temperature in tenths of Kelvins (4418)
1.3.6.1.4.1.318.1.1.13.5.3.7.19.1INTEGERread-writemandatory
airIRmPmCmp1StartTempWinterF
OBJECT-TYPE
Compressor 1 winter mode start temperature in tenths of degrees Fahrenheit (4418)
1.3.6.1.4.1.318.1.1.13.5.3.7.19.2INTEGERread-writemandatory
airIRmPmCmp1HysteresisWinter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.7.20
airIRmPmCmp1HysteresisWinterK
OBJECT-TYPE
Compressor 1 Winter mode hysteresis setting in tenths of Kelvins (4419)
1.3.6.1.4.1.318.1.1.13.5.3.7.20.1INTEGERread-writemandatory
airIRmPmCmp1HysteresisWinterF
OBJECT-TYPE
Compressor 1 Winter mode hysteresis setting in tenths of Fahrenheit (4419)
1.3.6.1.4.1.318.1.1.13.5.3.7.20.2INTEGERread-writemandatory
airIRmPmCmp1Runtime
OBJECT-TYPE
Compressor 1 runtime in hours (4428)
1.3.6.1.4.1.318.1.1.13.5.3.7.29INTEGERread-onlymandatory
airIRmPmCompressor2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.8
airIRmPmCmp2ManOperationActive
OBJECT-TYPE
Compressor 2 manual operation active (4501)
1.3.6.1.4.1.318.1.1.13.5.3.8.2INTEGER {automatic(1), manual(2)}read-onlymandatory
airIRmPmCmp2ManOperationState
OBJECT-TYPE
Compressor 2 manual operation state (4502)
1.3.6.1.4.1.318.1.1.13.5.3.8.3AirIRmControlStateread-onlymandatory
airIRmPmCmp2Running
OBJECT-TYPE
Compressor 2 running (4503)
1.3.6.1.4.1.318.1.1.13.5.3.8.4AirIRmActivityStateread-onlymandatory
airIRmPmCmp2StartTempSummer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.8.17
airIRmPmCmp2StartTempSummerK
OBJECT-TYPE
Compressor 2 summer mode start temperature in tenths of Kelvins (4516)
1.3.6.1.4.1.318.1.1.13.5.3.8.17.1INTEGERread-writemandatory
airIRmPmCmp2StartTempSummerF
OBJECT-TYPE
Compressor 2 summer mode start temperature in tenths of degrees Fahrenheit (4516)
1.3.6.1.4.1.318.1.1.13.5.3.8.17.2INTEGERread-writemandatory
airIRmPmCmp2HysteresisSummer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.8.18
airIRmPmCmp2HysteresisSummerK
OBJECT-TYPE
Compressor 2 summer mode hysteresis setting in tenths of Kelvins (4517)
1.3.6.1.4.1.318.1.1.13.5.3.8.18.1INTEGERread-writemandatory
airIRmPmCmp2HysteresisSummerF
OBJECT-TYPE
Compressor 2 summer mode hysteresis setting in tenths of Fahrenheit (4517)
1.3.6.1.4.1.318.1.1.13.5.3.8.18.2INTEGERread-writemandatory
airIRmPmCmp2StartTempWinter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.8.19
airIRmPmCmp2StartTempWinterK
OBJECT-TYPE
Compressor 2 winter mode start temperature in tenths of Kelvins (4518)
1.3.6.1.4.1.318.1.1.13.5.3.8.19.1INTEGERread-writemandatory
airIRmPmCmp2StartTempWinterF
OBJECT-TYPE
Compressor 2 winter mode start temperature in tenths of degrees Fahrenheit (4518)
1.3.6.1.4.1.318.1.1.13.5.3.8.19.2INTEGERread-writemandatory
airIRmPmCmp2HysteresisWinter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.8.20
airIRmPmCmp2HysteresisWinterK
OBJECT-TYPE
Compressor 2 Winter mode hysteresis setting in tenths of Kelvins (4519)
1.3.6.1.4.1.318.1.1.13.5.3.8.20.1INTEGERread-writemandatory
airIRmPmCmp2HysteresisWinterF
OBJECT-TYPE
Compressor 2 Winter mode hysteresis setting in tenths of Fahrenheit (4519)
1.3.6.1.4.1.318.1.1.13.5.3.8.20.2INTEGERread-writemandatory
airIRmPmCmp2Runtime
OBJECT-TYPE
Compressor 2 runtime in hours (4528)
1.3.6.1.4.1.318.1.1.13.5.3.8.29INTEGERread-onlymandatory
airIRmPmSuctionValve1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.9
airIRmPmSuctionValve2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.10
airIRmPmEheating1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.11
airIRmPmEheating1ManOpEnable
OBJECT-TYPE
Electric heater #1 manual operation enable (4801)
1.3.6.1.4.1.318.1.1.13.5.3.11.2AirIRmActivityStateread-onlymandatory
airIRmPmEheating1Running
OBJECT-TYPE
Electric heater #1 running state (4803)
1.3.6.1.4.1.318.1.1.13.5.3.11.4AirIRmControlStateread-onlymandatory
airIRmPmEheating1ManOpRunning
OBJECT-TYPE
Electric heater #1 running in manual operation mode (4804)
1.3.6.1.4.1.318.1.1.13.5.3.11.5AirIRmActivityStateread-onlymandatory
airIRmPmEheating1Type
OBJECT-TYPE
Electric heater #1 type (4808)
1.3.6.1.4.1.318.1.1.13.5.3.11.9INTEGER {direct(1), pwm(2)}read-onlymandatory
airIRmPmEheating1StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.11.10
airIRmPmEheating1StartTemperatureK
OBJECT-TYPE
Electric heater #1 start temperature in tenths of Kelvins (4809)
1.3.6.1.4.1.318.1.1.13.5.3.11.10.1INTEGERread-writemandatory
airIRmPmEheating1StartTemperatureF
OBJECT-TYPE
Electric heater #1 start temperature in tenths of degrees Fahrenheit (4809)
1.3.6.1.4.1.318.1.1.13.5.3.11.10.2INTEGERread-writemandatory
airIRmPmEheating1Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.11.11
airIRmPmEheating1HysteresisK
OBJECT-TYPE
Electric heater #1 hysteresis in tenths of Kelvins (4810)
1.3.6.1.4.1.318.1.1.13.5.3.11.11.1INTEGERread-writemandatory
airIRmPmEheating1HysteresisF
OBJECT-TYPE
Electric heater #1 hysteresis in tenths of degrees Fahrenheit (4810)
1.3.6.1.4.1.318.1.1.13.5.3.11.11.2INTEGERread-writemandatory
airIRmPmEheating1Runtime
OBJECT-TYPE
Electric heater #1 runtime in hours (4816)
1.3.6.1.4.1.318.1.1.13.5.3.11.17INTEGERread-onlymandatory
airIRmPmEheating2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.12
airIRmPmEheating2ManOpEnable
OBJECT-TYPE
Electric heater #2 manual operation enable (4901)
1.3.6.1.4.1.318.1.1.13.5.3.12.2AirIRmActivityStateread-onlymandatory
airIRmPmEheating2Running
OBJECT-TYPE
Electric heater #2 running state (4903)
1.3.6.1.4.1.318.1.1.13.5.3.12.4AirIRmControlStateread-onlymandatory
airIRmPmEheating2ManOpRunning
OBJECT-TYPE
Electric heater #2 running in manual operation mode (4904)
1.3.6.1.4.1.318.1.1.13.5.3.12.5AirIRmActivityStateread-onlymandatory
airIRmPmEheating2Type
OBJECT-TYPE
Electric heater #2 type (4908)
1.3.6.1.4.1.318.1.1.13.5.3.12.9INTEGER {direct(1), pwm(2)}read-onlymandatory
airIRmPmEheating2StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.12.10
airIRmPmEheating2StartTemperatureK
OBJECT-TYPE
Electric heater #2 start temperature in tenths of Kelvins (4909)
1.3.6.1.4.1.318.1.1.13.5.3.12.10.1INTEGERread-writemandatory
airIRmPmEheating2StartTemperatureF
OBJECT-TYPE
Electric heater #2 start temperature in tenths of degrees Fahrenheit (4909)
1.3.6.1.4.1.318.1.1.13.5.3.12.10.2INTEGERread-writemandatory
airIRmPmEheating2Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.12.11
airIRmPmEheating2HysteresisK
OBJECT-TYPE
Electric heater #2 hysteresis in tenths of Kelvins (4910)
1.3.6.1.4.1.318.1.1.13.5.3.12.11.1INTEGERread-writemandatory
airIRmPmEheating2HysteresisF
OBJECT-TYPE
Electric heater #2 hysteresis in tenths of degrees Fahrenheit (4910)
1.3.6.1.4.1.318.1.1.13.5.3.12.11.2INTEGERread-writemandatory
airIRmPmEheating2Runtime
OBJECT-TYPE
Electric heater #2 runtime in hours (4916)
1.3.6.1.4.1.318.1.1.13.5.3.12.17INTEGERread-onlymandatory
airIRmPmEheating3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.13
airIRmPmEheating3ManOpEnable
OBJECT-TYPE
Electric heater #3 manual operation enable (5001)
1.3.6.1.4.1.318.1.1.13.5.3.13.2AirIRmActivityStateread-onlymandatory
airIRmPmEheating3Running
OBJECT-TYPE
Electric heater #3 running state (5003)
1.3.6.1.4.1.318.1.1.13.5.3.13.4AirIRmControlStateread-onlymandatory
airIRmPmEheating3ManOpRunning
OBJECT-TYPE
Electric heater #3 running in manual operation mode (5004)
1.3.6.1.4.1.318.1.1.13.5.3.13.5AirIRmActivityStateread-onlymandatory
airIRmPmEheating3Type
OBJECT-TYPE
Electric heater #3 type (5008)
1.3.6.1.4.1.318.1.1.13.5.3.13.9INTEGER {direct(1), pwm(2)}read-onlymandatory
airIRmPmEheating3StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.13.10
airIRmPmEheating3StartTemperatureK
OBJECT-TYPE
Electric heater #3 start temperature in tenths of Kelvins (5009)
1.3.6.1.4.1.318.1.1.13.5.3.13.10.1INTEGERread-writemandatory
airIRmPmEheating3StartTemperatureF
OBJECT-TYPE
Electric heater #3 start temperature in tenths of degrees Fahrenheit (5009)
1.3.6.1.4.1.318.1.1.13.5.3.13.10.2INTEGERread-writemandatory
airIRmPmEheating3Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.13.11
airIRmPmEheating3HysteresisK
OBJECT-TYPE
Electric heater #3 hysteresis in tenths of Kelvins (5010)
1.3.6.1.4.1.318.1.1.13.5.3.13.11.1INTEGERread-writemandatory
airIRmPmEheating3HysteresisF
OBJECT-TYPE
Electric heater #3 hysteresis in tenths of degrees Fahrenheit (5010)
1.3.6.1.4.1.318.1.1.13.5.3.13.11.2INTEGERread-writemandatory
airIRmPmEheating3Runtime
OBJECT-TYPE
Electric heater #3 runtime in hours (5016)
1.3.6.1.4.1.318.1.1.13.5.3.13.17INTEGERread-onlymandatory
airIRmPmEheating4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.14
airIRmPmEheating4ManOpEnable
OBJECT-TYPE
Electric heater #4 manual operation enable (5101)
1.3.6.1.4.1.318.1.1.13.5.3.14.2AirIRmActivityStateread-onlymandatory
airIRmPmEheating4Running
OBJECT-TYPE
Electric heater #4 running state (5103)
1.3.6.1.4.1.318.1.1.13.5.3.14.4AirIRmControlStateread-onlymandatory
airIRmPmEheating4ManOpRunning
OBJECT-TYPE
Electric heater #4 running in manual operation mode (5104)
1.3.6.1.4.1.318.1.1.13.5.3.14.5AirIRmActivityStateread-onlymandatory
airIRmPmEheating4Type
OBJECT-TYPE
Electric heater #4 type (5108)
1.3.6.1.4.1.318.1.1.13.5.3.14.9INTEGER {direct(1), pwm(2)}read-onlymandatory
airIRmPmEheating4StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.14.10
airIRmPmEheating4StartTemperatureK
OBJECT-TYPE
Electric heater #4 start temperature in tenths of Kelvins (5109)
1.3.6.1.4.1.318.1.1.13.5.3.14.10.1INTEGERread-writemandatory
airIRmPmEheating4StartTemperatureF
OBJECT-TYPE
Electric heater #4 start temperature in tenths of degrees Fahrenheit (5109)
1.3.6.1.4.1.318.1.1.13.5.3.14.10.2INTEGERread-writemandatory
airIRmPmEheating4Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.14.11
airIRmPmEheating4HysteresisK
OBJECT-TYPE
Electric heater #4 hysteresis in tenths of Kelvins (5110)
1.3.6.1.4.1.318.1.1.13.5.3.14.11.1INTEGERread-writemandatory
airIRmPmEheating4HysteresisF
OBJECT-TYPE
Electric heater #4 hysteresis in tenths of degrees Fahrenheit (5110)
1.3.6.1.4.1.318.1.1.13.5.3.14.11.2INTEGERread-writemandatory
airIRmPmEheating4Runtime
OBJECT-TYPE
Electric heater #4 runtime in hours (5116)
1.3.6.1.4.1.318.1.1.13.5.3.14.17INTEGERread-onlymandatory
airIRmPmGECWvalve
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.15
airIRmPmGECWvalveManOpEnable
OBJECT-TYPE
GE/CW valve manual operation enable (5201)
1.3.6.1.4.1.318.1.1.13.5.3.15.2INTEGERread-onlymandatory
airIRmPmGECWvalveStartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.15.9
airIRmPmGECWvalveStartTemperatureK
OBJECT-TYPE
GE/CW valve start temperature in tenths of Kelvins (5208)
1.3.6.1.4.1.318.1.1.13.5.3.15.9.1INTEGERread-writemandatory
airIRmPmGECWvalveStartTemperatureF
OBJECT-TYPE
GE/CW valve start temperature in tenths of degrees Fahrenheit (5208)
1.3.6.1.4.1.318.1.1.13.5.3.15.9.2INTEGERread-writemandatory
airIRmPmGECWvalveLinearRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.15.10
airIRmPmGECWvalveLinearRangeK
OBJECT-TYPE
GE/CW valve linear range in tenths of Kelvins (5209)
1.3.6.1.4.1.318.1.1.13.5.3.15.10.1INTEGERread-writemandatory
airIRmPmGECWvalveLinearRangeF
OBJECT-TYPE
GE/CW valve linear range in tenths of degrees Fahrenheit (5209)
1.3.6.1.4.1.318.1.1.13.5.3.15.10.2INTEGERread-writemandatory
airIRmPmGECWvalveGEOffTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.15.12
airIRmPmGECWvalveGEOffTempC
OBJECT-TYPE
GE/CW valve GE off temperature in tenths of degrees Celsius (5211)
1.3.6.1.4.1.318.1.1.13.5.3.15.12.1INTEGERread-writemandatory
airIRmPmGECWvalveGEOffTempF
OBJECT-TYPE
GE/CW valve GE off temperature in tenths of degrees Fahrenheit (5211)
1.3.6.1.4.1.318.1.1.13.5.3.15.12.2INTEGERread-writemandatory
airIRmPmGECWvalveOpeningGrade
OBJECT-TYPE
GE/CW valve opening grade in percent (5214)
1.3.6.1.4.1.318.1.1.13.5.3.15.15INTEGERread-onlymandatory
airIRmPmGECWvalveManOpOpeningGrade
OBJECT-TYPE
GE/CW valve manual operation opening grade in percent (5215)
1.3.6.1.4.1.318.1.1.13.5.3.15.16INTEGERread-onlymandatory
airIRmPmGvalve
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.16
airIRmPmGvalveManOperationEnable
OBJECT-TYPE
G-valve manual operation enable (5301)
1.3.6.1.4.1.318.1.1.13.5.3.16.2AirIRmActivityStateread-onlymandatory
airIRmPmGvalvePreOpeningTime
OBJECT-TYPE
G-valve pre-opening time in seconds (5310)
1.3.6.1.4.1.318.1.1.13.5.3.16.11INTEGERread-onlymandatory
airIRmPmGvalvePreOpeningGrade
OBJECT-TYPE
G-valve pre-opening grade in percent (5311)
1.3.6.1.4.1.318.1.1.13.5.3.16.12INTEGERread-onlymandatory
airIRmPmGvalveOpeningGrade
OBJECT-TYPE
G-valve opening grade in percent (5312)
1.3.6.1.4.1.318.1.1.13.5.3.16.13INTEGERread-onlymandatory
airIRmPmGvalveManOpOpeningGrade
OBJECT-TYPE
G-valve manual operation opening grade in percent (5313)
1.3.6.1.4.1.318.1.1.13.5.3.16.14INTEGERread-onlymandatory
airIRmPmDrycooler1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.17
airIRmPmDrycooler1ManOpEnable
OBJECT-TYPE
Drycooler 1 manual operation enable setting (5401)
1.3.6.1.4.1.318.1.1.13.5.3.17.2AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler1Running
OBJECT-TYPE
Drycooler 1 running (5402)
1.3.6.1.4.1.318.1.1.13.5.3.17.3AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler1ManOpRunning
OBJECT-TYPE
Drycooler 1 manual operation running (5404)
1.3.6.1.4.1.318.1.1.13.5.3.17.5AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler1WinterStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.17.9
airIRmPmDrycooler1WinterStartTempC
OBJECT-TYPE
Drycooler 1 winter mode start temperature in tenths of degrees Celsius (5408)
1.3.6.1.4.1.318.1.1.13.5.3.17.9.1INTEGERread-writemandatory
airIRmPmDrycooler1WinterStartTempF
OBJECT-TYPE
Drycooler 1 winter mode start temperature in tenths of degrees Fahrenheit (5408)
1.3.6.1.4.1.318.1.1.13.5.3.17.9.2INTEGERread-writemandatory
airIRmPmDrycooler1SummerStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.17.10
airIRmPmDrycooler1SummerStartTempC
OBJECT-TYPE
Drycooler 1 summer mode start temperature in tenths of degrees Celsius (5409)
1.3.6.1.4.1.318.1.1.13.5.3.17.10.1INTEGERread-writemandatory
airIRmPmDrycooler1SummerStartTempF
OBJECT-TYPE
Drycooler 1 summer mode start temperature in tenths of degrees Fahrenheit (5409)
1.3.6.1.4.1.318.1.1.13.5.3.17.10.2INTEGERread-writemandatory
airIRmPmDrycooler1Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.17.11
airIRmPmDrycooler1HysteresisK
OBJECT-TYPE
Drycooler 1 hysteresis in tenths of Kelvins (5410)
1.3.6.1.4.1.318.1.1.13.5.3.17.11.1INTEGERread-writemandatory
airIRmPmDrycooler1HysteresisF
OBJECT-TYPE
Drycooler 1 hysteresis in tenths of degrees Fahrenheit (5410)
1.3.6.1.4.1.318.1.1.13.5.3.17.11.2INTEGERread-writemandatory
airIRmPmDrycooler1Runtime
OBJECT-TYPE
Drycooler 1 runtime in hours (5415)
1.3.6.1.4.1.318.1.1.13.5.3.17.16INTEGERread-onlymandatory
airIRmPmDrycooler2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.18
airIRmPmDrycooler2ManOpEnable
OBJECT-TYPE
Drycooler 2 manual operation enable setting (5501)
1.3.6.1.4.1.318.1.1.13.5.3.18.2AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler2Running
OBJECT-TYPE
Drycooler 2 running (5502)
1.3.6.1.4.1.318.1.1.13.5.3.18.3AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler2ManOpRunning
OBJECT-TYPE
Drycooler 2 manual operation running (5504)
1.3.6.1.4.1.318.1.1.13.5.3.18.5AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler2WinterStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.18.9
airIRmPmDrycooler2WinterStartTempC
OBJECT-TYPE
Drycooler 2 winter mode start temperature in tenths of degrees Celsius (5508)
1.3.6.1.4.1.318.1.1.13.5.3.18.9.1INTEGERread-writemandatory
airIRmPmDrycooler2WinterStartTempF
OBJECT-TYPE
Drycooler 2 winter mode start temperature in tenths of degrees Fahrenheit (5508)
1.3.6.1.4.1.318.1.1.13.5.3.18.9.2INTEGERread-writemandatory
airIRmPmDrycooler2SummerStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.18.10
airIRmPmDrycooler2SummerStartTempC
OBJECT-TYPE
Drycooler 2 summer mode start temperature in tenths of degrees Celsius (5509)
1.3.6.1.4.1.318.1.1.13.5.3.18.10.1INTEGERread-writemandatory
airIRmPmDrycooler2SummerStartTempF
OBJECT-TYPE
Drycooler 2 summer mode start temperature in tenths of degrees Fahrenheit (5509)
1.3.6.1.4.1.318.1.1.13.5.3.18.10.2INTEGERread-writemandatory
airIRmPmDrycooler2Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.18.11
airIRmPmDrycooler2HysteresisK
OBJECT-TYPE
Drycooler 2 hysteresis in tenths of Kelvins (5510)
1.3.6.1.4.1.318.1.1.13.5.3.18.11.1INTEGERread-writemandatory
airIRmPmDrycooler2HysteresisF
OBJECT-TYPE
Drycooler 2 hysteresis in tenths of degrees Fahrenheit (5510)
1.3.6.1.4.1.318.1.1.13.5.3.18.11.2INTEGERread-writemandatory
airIRmPmDrycooler2Runtime
OBJECT-TYPE
Drycooler 2 runtime in hours (5515)
1.3.6.1.4.1.318.1.1.13.5.3.18.16INTEGERread-onlymandatory
airIRmPmDrycooler3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.19
airIRmPmDrycooler3ManOpEnable
OBJECT-TYPE
Drycooler 3 manual operation enable setting (5601)
1.3.6.1.4.1.318.1.1.13.5.3.19.2AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler3Running
OBJECT-TYPE
Drycooler 3 running (5602)
1.3.6.1.4.1.318.1.1.13.5.3.19.3AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler3ManOpRunning
OBJECT-TYPE
Drycooler 3 manual operation running (5604)
1.3.6.1.4.1.318.1.1.13.5.3.19.5AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler3WinterStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.19.9
airIRmPmDrycooler3WinterStartTempC
OBJECT-TYPE
Drycooler 3 winter mode start temperature in tenths of degrees Celsius (5608)
1.3.6.1.4.1.318.1.1.13.5.3.19.9.1INTEGERread-writemandatory
airIRmPmDrycooler3WinterStartTempF
OBJECT-TYPE
Drycooler 3 winter mode start temperature in tenths of degrees Fahrenheit (5608)
1.3.6.1.4.1.318.1.1.13.5.3.19.9.2INTEGERread-writemandatory
airIRmPmDrycooler3SummerStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.19.10
airIRmPmDrycooler3SummerStartTempC
OBJECT-TYPE
Drycooler 3 summer mode start temperature in tenths of degrees Celsius (5609)
1.3.6.1.4.1.318.1.1.13.5.3.19.10.1INTEGERread-writemandatory
airIRmPmDrycooler3SummerStartTempF
OBJECT-TYPE
Drycooler 3 summer mode start temperature in tenths of degrees Fahrenheit (5609)
1.3.6.1.4.1.318.1.1.13.5.3.19.10.2INTEGERread-writemandatory
airIRmPmDrycooler3Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.19.11
airIRmPmDrycooler3HysteresisK
OBJECT-TYPE
Drycooler 3 hysteresis in tenths of Kelvins (5610)
1.3.6.1.4.1.318.1.1.13.5.3.19.11.1INTEGERread-writemandatory
airIRmPmDrycooler3HysteresisF
OBJECT-TYPE
Drycooler 3 hysteresis in tenths of degrees Fahrenheit (5610)
1.3.6.1.4.1.318.1.1.13.5.3.19.11.2INTEGERread-writemandatory
airIRmPmDrycooler3Runtime
OBJECT-TYPE
Drycooler 3 runtime in hours (5615)
1.3.6.1.4.1.318.1.1.13.5.3.19.16INTEGERread-onlymandatory
airIRmPmDrycooler4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.20
airIRmPmDrycooler4ManOpEnable
OBJECT-TYPE
Drycooler 4 manual operation enable setting (5701)
1.3.6.1.4.1.318.1.1.13.5.3.20.2AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler4Running
OBJECT-TYPE
Drycooler 4 running (5702)
1.3.6.1.4.1.318.1.1.13.5.3.20.3AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler4ManOpRunning
OBJECT-TYPE
Drycooler 4 manual operation running (5704)
1.3.6.1.4.1.318.1.1.13.5.3.20.5AirIRmActivityStateread-onlymandatory
airIRmPmDrycooler4WinterStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.20.9
airIRmPmDrycooler4WinterStartTempC
OBJECT-TYPE
Drycooler 4 winter mode start temperature in tenths of degrees Celsius (5708)
1.3.6.1.4.1.318.1.1.13.5.3.20.9.1INTEGERread-writemandatory
airIRmPmDrycooler4WinterStartTempF
OBJECT-TYPE
Drycooler 4 winter mode start temperature in tenths of degrees Fahrenheit (5708)
1.3.6.1.4.1.318.1.1.13.5.3.20.9.2INTEGERread-writemandatory
airIRmPmDrycooler4SummerStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.20.10
airIRmPmDrycooler4SummerStartTempC
OBJECT-TYPE
Drycooler 4 summer mode start temperature in tenths of degrees Celsius (5709)
1.3.6.1.4.1.318.1.1.13.5.3.20.10.1INTEGERread-writemandatory
airIRmPmDrycooler4SummerStartTempF
OBJECT-TYPE
Drycooler 4 summer mode start temperature in tenths of degrees Fahrenheit (5709)
1.3.6.1.4.1.318.1.1.13.5.3.20.10.2INTEGERread-writemandatory
airIRmPmDrycooler4Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.20.11
airIRmPmDrycooler4HysteresisK
OBJECT-TYPE
Drycooler 4 hysteresis in tenths of Kelvins (5710)
1.3.6.1.4.1.318.1.1.13.5.3.20.11.1INTEGERread-writemandatory
airIRmPmDrycooler4HysteresisF
OBJECT-TYPE
Drycooler 4 hysteresis in tenths of degrees Fahrenheit (5710)
1.3.6.1.4.1.318.1.1.13.5.3.20.11.2INTEGERread-writemandatory
airIRmPmDrycooler4Runtime
OBJECT-TYPE
Drycooler 4 runtime in hours (5715)
1.3.6.1.4.1.318.1.1.13.5.3.20.16INTEGERread-onlymandatory
airIRmPmPump1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.21
airIRmPmPump1ManOpEnable
OBJECT-TYPE
Pump 1 manual operation enable state (5801)
1.3.6.1.4.1.318.1.1.13.5.3.21.2AirIRmActivityStateread-onlymandatory
airIRmPmPump1Running
OBJECT-TYPE
Pump 1 running (5802)
1.3.6.1.4.1.318.1.1.13.5.3.21.3AirIRmActivityStateread-onlymandatory
airIRmPmPump1ManOpRunning
OBJECT-TYPE
Pump 1 manual operation running (5805)
1.3.6.1.4.1.318.1.1.13.5.3.21.6AirIRmActivityStateread-onlymandatory
airIRmPmPump1StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.21.10
airIRmPmPump1StartTemperatureK
OBJECT-TYPE
Pump 1 starting temperature in tenths of Kelvins (5809)
1.3.6.1.4.1.318.1.1.13.5.3.21.10.1INTEGERread-writemandatory
airIRmPmPump1StartTemperatureF
OBJECT-TYPE
Pump 1 starting temperature in tenths of degrees Fahrenheit (5809)
1.3.6.1.4.1.318.1.1.13.5.3.21.10.2INTEGERread-writemandatory
airIRmPmPump1Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.21.11
airIRmPmPump1HysteresisK
OBJECT-TYPE
Pump 1 hysteresis in tenths of Kelvins (5810)
1.3.6.1.4.1.318.1.1.13.5.3.21.11.1INTEGERread-writemandatory
airIRmPmPump1HysteresisF
OBJECT-TYPE
Pump 1 hysteresis in tenths of degrees Fahrenheit (5810)
1.3.6.1.4.1.318.1.1.13.5.3.21.11.2INTEGERread-writemandatory
airIRmPmPump1LinearRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.21.12
airIRmPmPump1LinearRangeK
OBJECT-TYPE
Pump 1 linear range in tenths of Kelvins (5811)
1.3.6.1.4.1.318.1.1.13.5.3.21.12.1INTEGERread-writemandatory
airIRmPmPump1LinearRangeF
OBJECT-TYPE
Pump 1 linear range in tenths of degrees Fahrenheit (5811)
1.3.6.1.4.1.318.1.1.13.5.3.21.12.2INTEGERread-writemandatory
airIRmPmPump1PressureSetpoint
OBJECT-TYPE
Pump 1 pressure setpoint in tenths of Bars (5812)
1.3.6.1.4.1.318.1.1.13.5.3.21.13INTEGERread-writemandatory
airIRmPmPump1Runtime
OBJECT-TYPE
Pump 1 runtime in hours (5820)
1.3.6.1.4.1.318.1.1.13.5.3.21.21INTEGERread-onlymandatory
airIRmPmPump1Speed
OBJECT-TYPE
Pump 1 speed in percent (5821)
1.3.6.1.4.1.318.1.1.13.5.3.21.22INTEGERread-onlymandatory
airIRmPmPump1ControlCycle
OBJECT-TYPE
Pump 1 control cycle length in seconds (5827)
1.3.6.1.4.1.318.1.1.13.5.3.21.28INTEGERread-writemandatory
airIRmPmPump1MaxAdjust
OBJECT-TYPE
Pump 1 maximum adjustment in percent (5828)
1.3.6.1.4.1.318.1.1.13.5.3.21.29INTEGERread-writemandatory
airIRmPmPump1ControlFactor
OBJECT-TYPE
Pump 1 control factor setting (5829)
1.3.6.1.4.1.318.1.1.13.5.3.21.30INTEGERread-writemandatory
airIRmPmPump2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.22
airIRmPmPump2ManOpEnable
OBJECT-TYPE
Pump 2 manual operation enable state (5901)
1.3.6.1.4.1.318.1.1.13.5.3.22.2AirIRmActivityStateread-onlymandatory
airIRmPmPump2Running
OBJECT-TYPE
Pump 2 running (5902)
1.3.6.1.4.1.318.1.1.13.5.3.22.3AirIRmActivityStateread-onlymandatory
airIRmPmPump2ManOpRunning
OBJECT-TYPE
Pump 2 manual operation running (5905)
1.3.6.1.4.1.318.1.1.13.5.3.22.6AirIRmActivityStateread-onlymandatory
airIRmPmPump2StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.22.10
airIRmPmPump2StartTemperatureK
OBJECT-TYPE
Pump 2 starting temperature in tenths of Kelvins (5909)
1.3.6.1.4.1.318.1.1.13.5.3.22.10.1INTEGERread-writemandatory
airIRmPmPump2StartTemperatureF
OBJECT-TYPE
Pump 2 starting temperature in tenths of degrees Fahrenheit (5909)
1.3.6.1.4.1.318.1.1.13.5.3.22.10.2INTEGERread-writemandatory
airIRmPmPump2Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.22.11
airIRmPmPump2HysteresisK
OBJECT-TYPE
Pump 2 hysteresis in tenths of Kelvins (5910)
1.3.6.1.4.1.318.1.1.13.5.3.22.11.1INTEGERread-writemandatory
airIRmPmPump2HysteresisF
OBJECT-TYPE
Pump 2 hysteresis in tenths of degrees Fahrenheit (5910)
1.3.6.1.4.1.318.1.1.13.5.3.22.11.2INTEGERread-writemandatory
airIRmPmPump2LinearRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.22.12
airIRmPmPump2LinearRangeK
OBJECT-TYPE
Pump 2 linear range in tenths of Kelvins (5911)
1.3.6.1.4.1.318.1.1.13.5.3.22.12.1INTEGERread-writemandatory
airIRmPmPump2LinearRangeF
OBJECT-TYPE
Pump 2 linear range in tenths of degrees Fahrenheit (5911)
1.3.6.1.4.1.318.1.1.13.5.3.22.12.2INTEGERread-writemandatory
airIRmPmPump2PressureSetpoint
OBJECT-TYPE
Pump 2 pressure setpoint in tenths of Bars (5912)
1.3.6.1.4.1.318.1.1.13.5.3.22.13INTEGERread-writemandatory
airIRmPmPump2Runtime
OBJECT-TYPE
Pump 2 runtime in hours (5920)
1.3.6.1.4.1.318.1.1.13.5.3.22.21INTEGERread-onlymandatory
airIRmPmPump2Speed
OBJECT-TYPE
Pump 2 speed in percent (5921)
1.3.6.1.4.1.318.1.1.13.5.3.22.22INTEGERread-onlymandatory
airIRmPmPump2ControlCycle
OBJECT-TYPE
Pump 2 control cycle length in seconds (5927)
1.3.6.1.4.1.318.1.1.13.5.3.22.28INTEGERread-writemandatory
airIRmPmPump2MaxAdjust
OBJECT-TYPE
Pump 2 maximum adjustment in percent (5928)
1.3.6.1.4.1.318.1.1.13.5.3.22.29INTEGERread-writemandatory
airIRmPmPump2ControlFactor
OBJECT-TYPE
Pump 2 control factor setting (5929)
1.3.6.1.4.1.318.1.1.13.5.3.22.30INTEGERread-writemandatory
airIRmPmPump3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.23
airIRmPmPump3ManOpEnable
OBJECT-TYPE
Pump 3 manual operation enable state (6001)
1.3.6.1.4.1.318.1.1.13.5.3.23.2AirIRmActivityStateread-onlymandatory
airIRmPmPump3Running
OBJECT-TYPE
Pump 3 running (6002)
1.3.6.1.4.1.318.1.1.13.5.3.23.3AirIRmActivityStateread-onlymandatory
airIRmPmPump3ManOpRunning
OBJECT-TYPE
Pump 3 manual operation running (6005)
1.3.6.1.4.1.318.1.1.13.5.3.23.6AirIRmActivityStateread-onlymandatory
airIRmPmPump3StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.23.10
airIRmPmPump3StartTemperatureK
OBJECT-TYPE
Pump 3 starting temperature in tenths of Kelvins (6009)
1.3.6.1.4.1.318.1.1.13.5.3.23.10.1INTEGERread-writemandatory
airIRmPmPump3StartTemperatureF
OBJECT-TYPE
Pump 3 starting temperature in tenths of degrees Fahrenheit (6009)
1.3.6.1.4.1.318.1.1.13.5.3.23.10.2INTEGERread-writemandatory
airIRmPmPump3Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.23.11
airIRmPmPump3HysteresisK
OBJECT-TYPE
Pump 3 hysteresis in tenths of Kelvins (6010)
1.3.6.1.4.1.318.1.1.13.5.3.23.11.1INTEGERread-writemandatory
airIRmPmPump3HysteresisF
OBJECT-TYPE
Pump 3 hysteresis in tenths of degrees Fahrenheit (6010)
1.3.6.1.4.1.318.1.1.13.5.3.23.11.2INTEGERread-writemandatory
airIRmPmPump3LinearRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.23.12
airIRmPmPump3LinearRangeK
OBJECT-TYPE
Pump 3 linear range in tenths of Kelvins (6011)
1.3.6.1.4.1.318.1.1.13.5.3.23.12.1INTEGERread-writemandatory
airIRmPmPump3LinearRangeF
OBJECT-TYPE
Pump 3 linear range in tenths of degrees Fahrenheit (6011)
1.3.6.1.4.1.318.1.1.13.5.3.23.12.2INTEGERread-writemandatory
airIRmPmPump3PressureSetpoint
OBJECT-TYPE
Pump 3 pressure setpoint in tenths of Bars (6012)
1.3.6.1.4.1.318.1.1.13.5.3.23.13INTEGERread-writemandatory
airIRmPmPump3Runtime
OBJECT-TYPE
Pump 3 runtime in hours (6020)
1.3.6.1.4.1.318.1.1.13.5.3.23.21INTEGERread-onlymandatory
airIRmPmPump3Speed
OBJECT-TYPE
Pump 3 speed in percent (6021)
1.3.6.1.4.1.318.1.1.13.5.3.23.22INTEGERread-onlymandatory
airIRmPmPump3ControlCycle
OBJECT-TYPE
Pump 3 control cycle length in seconds (6027)
1.3.6.1.4.1.318.1.1.13.5.3.23.28INTEGERread-writemandatory
airIRmPmPump3MaxAdjust
OBJECT-TYPE
Pump 3 maximum adjustment in percent (6028)
1.3.6.1.4.1.318.1.1.13.5.3.23.29INTEGERread-writemandatory
airIRmPmPump3ControlFactor
OBJECT-TYPE
Pump 3 control factor setting (6029)
1.3.6.1.4.1.318.1.1.13.5.3.23.30INTEGERread-writemandatory
airIRmPmPump4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.24
airIRmPmPump4ManOpEnable
OBJECT-TYPE
Pump 4 manual operation enable state (6101)
1.3.6.1.4.1.318.1.1.13.5.3.24.2AirIRmActivityStateread-onlymandatory
airIRmPmPump4Running
OBJECT-TYPE
Pump 4 running (6102)
1.3.6.1.4.1.318.1.1.13.5.3.24.3AirIRmActivityStateread-onlymandatory
airIRmPmPump4ManOpRunning
OBJECT-TYPE
Pump 4 manual operation running (6105)
1.3.6.1.4.1.318.1.1.13.5.3.24.6AirIRmActivityStateread-onlymandatory
airIRmPmPump4StartTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.24.10
airIRmPmPump4StartTemperatureK
OBJECT-TYPE
Pump 4 starting temperature in tenths of Kelvins (6109)
1.3.6.1.4.1.318.1.1.13.5.3.24.10.1INTEGERread-writemandatory
airIRmPmPump4StartTemperatureF
OBJECT-TYPE
Pump 4 starting temperature in tenths of degrees Fahrenheit (6109)
1.3.6.1.4.1.318.1.1.13.5.3.24.10.2INTEGERread-writemandatory
airIRmPmPump4Hysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.24.11
airIRmPmPump4HysteresisK
OBJECT-TYPE
Pump 4 hysteresis in tenths of Kelvins (6110)
1.3.6.1.4.1.318.1.1.13.5.3.24.11.1INTEGERread-writemandatory
airIRmPmPump4HysteresisF
OBJECT-TYPE
Pump 4 hysteresis in tenths of degrees Fahrenheit (6110)
1.3.6.1.4.1.318.1.1.13.5.3.24.11.2INTEGERread-writemandatory
airIRmPmPump4LinearRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.24.12
airIRmPmPump4LinearRangeK
OBJECT-TYPE
Pump 4 linear range in tenths of Kelvins (6111)
1.3.6.1.4.1.318.1.1.13.5.3.24.12.1INTEGERread-writemandatory
airIRmPmPump4LinearRangeF
OBJECT-TYPE
Pump 4 linear range in tenths of degrees Fahrenheit (6111)
1.3.6.1.4.1.318.1.1.13.5.3.24.12.2INTEGERread-writemandatory
airIRmPmPump4PressureSetpoint
OBJECT-TYPE
Pump 4 pressure setpoint in tenths of Bars (6112)
1.3.6.1.4.1.318.1.1.13.5.3.24.13INTEGERread-writemandatory
airIRmPmPump4Runtime
OBJECT-TYPE
Pump 4 runtime in hours (6120)
1.3.6.1.4.1.318.1.1.13.5.3.24.21INTEGERread-onlymandatory
airIRmPmPump4Speed
OBJECT-TYPE
Pump 4 speed in percent (6121)
1.3.6.1.4.1.318.1.1.13.5.3.24.22INTEGERread-onlymandatory
airIRmPmPump4ControlCycle
OBJECT-TYPE
Pump 4 control cycle length in seconds (6127)
1.3.6.1.4.1.318.1.1.13.5.3.24.28INTEGERread-writemandatory
airIRmPmPump4MaxAdjust
OBJECT-TYPE
Pump 4 maximum adjustment in percent (6128)
1.3.6.1.4.1.318.1.1.13.5.3.24.29INTEGERread-writemandatory
airIRmPmPump4ControlFactor
OBJECT-TYPE
Pump 4 control factor setting (6129)
1.3.6.1.4.1.318.1.1.13.5.3.24.30INTEGERread-writemandatory
airIRmPmHotgasHeating
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.25
airIRmPmHotgasHeatRunning
OBJECT-TYPE
Hotgas heat running state. (6202)
1.3.6.1.4.1.318.1.1.13.5.3.25.3AirIRmControlStateread-onlymandatory
airIRmPmPWWHeating
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.26
airIRmPmPWWHeatingManOpEnable
OBJECT-TYPE
PWW-heating manual operation enable (6301)
1.3.6.1.4.1.318.1.1.13.5.3.26.2AirIRmActivityStateread-onlymandatory
airIRmPmPWWHeatingRunning
OBJECT-TYPE
PWW-heating running (6302)
1.3.6.1.4.1.318.1.1.13.5.3.26.3AirIRmActivityStateread-onlymandatory
airIRmPmPWWHeatingManOpRunning
OBJECT-TYPE
PWW-heating manual operation running (6303)
1.3.6.1.4.1.318.1.1.13.5.3.26.4AirIRmActivityStateread-onlymandatory
airIRmPmPWWHeatingType
OBJECT-TYPE
PWW-heating type (6308)
1.3.6.1.4.1.318.1.1.13.5.3.26.9INTEGER {direct(1), undefined(2)}read-onlymandatory
airIRmPmPWWHeatingStartTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.26.10
airIRmPmPWWHeatingStartTempK
OBJECT-TYPE
PWW-heating starting temperature in Kelvins (6309)
1.3.6.1.4.1.318.1.1.13.5.3.26.10.1INTEGERread-writemandatory
airIRmPmPWWHeatingStartTempF
OBJECT-TYPE
PWW-heating starting temperature in degrees Fahrenheit (6309)
1.3.6.1.4.1.318.1.1.13.5.3.26.10.2INTEGERread-writemandatory
airIRmPmPWWHeatingHysteresis
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.26.12
airIRmPmPWWHeatingHysteresisK
OBJECT-TYPE
PWW-heating hysteresis in Kelvins (6311)
1.3.6.1.4.1.318.1.1.13.5.3.26.12.1INTEGERread-writemandatory
airIRmPmPWWHeatingHysteresisF
OBJECT-TYPE
PWW-heating hysteresis in degrees Fahrenheit (6311)
1.3.6.1.4.1.318.1.1.13.5.3.26.12.2INTEGERread-writemandatory
airIRmPmPWWHeatingLinearRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.26.13
airIRmPmPWWHeatingLinearRangeK
OBJECT-TYPE
PWW-heating linear range in Kelvins (6312)
1.3.6.1.4.1.318.1.1.13.5.3.26.13.1INTEGERread-writemandatory
airIRmPmPWWHeatingLinearRangeF
OBJECT-TYPE
PWW-heating linear range in degrees Fahrenheit (6312)
1.3.6.1.4.1.318.1.1.13.5.3.26.13.2INTEGERread-writemandatory
airIRmPmPWWHeatingCurrentValue
OBJECT-TYPE
PWW-heating current value in percent (6315)
1.3.6.1.4.1.318.1.1.13.5.3.26.16INTEGERread-writemandatory
airIRmPmPWWHeatingManOpValue
OBJECT-TYPE
PWW-heating manual operation value in percent (6316)
1.3.6.1.4.1.318.1.1.13.5.3.26.17INTEGERread-writemandatory
airIRmPmHumidifier1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.27
airIRmPmHumidifier1ManOpEnable
OBJECT-TYPE
Humidifier #1 manual operation enable (6401)
1.3.6.1.4.1.318.1.1.13.5.3.27.2AirIRmActivityStateread-onlymandatory
airIRmPmHumidifier1Running
OBJECT-TYPE
Humidifier #1 running state (6402)
1.3.6.1.4.1.318.1.1.13.5.3.27.3AirIRmControlStateread-onlymandatory
airIRmPmHumidifier1ManOpRunning
OBJECT-TYPE
Humidifier #1 manual operation running state (6404)
1.3.6.1.4.1.318.1.1.13.5.3.27.5AirIRmActivityStateread-onlymandatory
airIRmPmHumidifier1Type
OBJECT-TYPE
Humidifier #1 type (6416)
1.3.6.1.4.1.318.1.1.13.5.3.27.17INTEGER {direct(1), proportional(2)}read-onlymandatory
airIRmPmHumidifier1StartHumidity
OBJECT-TYPE
Humidifier #1 start humidity in tenths of percent relative humidity (6417)
1.3.6.1.4.1.318.1.1.13.5.3.27.18INTEGERread-writemandatory
airIRmPmHumidifier1Hysteresis
OBJECT-TYPE
Humidifier #1 hysteresis in tenths of percent relative humidity (6419)
1.3.6.1.4.1.318.1.1.13.5.3.27.20INTEGERread-writemandatory
airIRmPmHumidifier1LinearRange
OBJECT-TYPE
Humidifier #1 linear range in tenths of percent relative humidity per Kelvin (6420)
1.3.6.1.4.1.318.1.1.13.5.3.27.21INTEGERread-writemandatory
airIRmPmHumidifier1Runtime
OBJECT-TYPE
Humidifier #1 runtime in hours (6426)
1.3.6.1.4.1.318.1.1.13.5.3.27.27INTEGERread-onlymandatory
airIRmPmHumidifier1CurrentValue
OBJECT-TYPE
Humidifier #1 current value in percent (6427)
1.3.6.1.4.1.318.1.1.13.5.3.27.28INTEGERread-onlymandatory
airIRmPmHumidifier1ManOpValue
OBJECT-TYPE
Humidifier #1 manual operation value in percent (6428)
1.3.6.1.4.1.318.1.1.13.5.3.27.29INTEGERread-writemandatory
airIRmPmHumidifier2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.28
airIRmPmHumidifier2ManOpEnable
OBJECT-TYPE
Humidifier #2 manual operation enable (6501)
1.3.6.1.4.1.318.1.1.13.5.3.28.2AirIRmActivityStateread-onlymandatory
airIRmPmHumidifier2Running
OBJECT-TYPE
Humidifier #2 running state (6502)
1.3.6.1.4.1.318.1.1.13.5.3.28.3AirIRmControlStateread-onlymandatory
airIRmPmHumidifier2ManOpRunning
OBJECT-TYPE
Humidifier #2 manual operation running state (6504)
1.3.6.1.4.1.318.1.1.13.5.3.28.5AirIRmActivityStateread-onlymandatory
airIRmPmHumidifier2Type
OBJECT-TYPE
Humidifier #2 type (6516)
1.3.6.1.4.1.318.1.1.13.5.3.28.17INTEGER {direct(1), proportional(2)}read-onlymandatory
airIRmPmHumidifier2StartHumidity
OBJECT-TYPE
Humidifier #2 start humidity in tenths of percent relative humidity (6517)
1.3.6.1.4.1.318.1.1.13.5.3.28.18INTEGERread-writemandatory
airIRmPmHumidifier2Hysteresis
OBJECT-TYPE
Humidifier #2 hysteresis in tenths of percent relative humidity (6519)
1.3.6.1.4.1.318.1.1.13.5.3.28.20INTEGERread-writemandatory
airIRmPmHumidifier2LinearRange
OBJECT-TYPE
Humidifier #2 linear range in tenths of percent relative humidity per Kelvin (6520)
1.3.6.1.4.1.318.1.1.13.5.3.28.21INTEGERread-writemandatory
airIRmPmHumidifier2Runtime
OBJECT-TYPE
Humidifier #2 runtime in hours (6526)
1.3.6.1.4.1.318.1.1.13.5.3.28.27INTEGERread-onlymandatory
airIRmPmHumidifier2CurrentValue
OBJECT-TYPE
Humidifier #2 current value in percent (6527)
1.3.6.1.4.1.318.1.1.13.5.3.28.28INTEGERread-onlymandatory
airIRmPmHumidifier2ManOpValue
OBJECT-TYPE
Humidifier #2 manual operation value in percent (6528)
1.3.6.1.4.1.318.1.1.13.5.3.28.29INTEGERread-writemandatory
airIRmPmDehumidification
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.31
airIRmPmDehumidificManOpEnable
OBJECT-TYPE
Dehumidifier manual operation enable setting (6801)
1.3.6.1.4.1.318.1.1.13.5.3.31.2AirIRmActivityStateread-onlymandatory
airIRmPmDehumidificRunning
OBJECT-TYPE
Dehumidifier running state (6802)
1.3.6.1.4.1.318.1.1.13.5.3.31.3AirIRmControlStateread-onlymandatory
airIRmPmDehumidificManOpRunning
OBJECT-TYPE
Dehumidifier manual operation running (6804)
1.3.6.1.4.1.318.1.1.13.5.3.31.5AirIRmActivityStateread-onlymandatory
airIRmPmDehumidificStartHumidity
OBJECT-TYPE
Dehumidifier start humidity in tenths of percent relative humidity (6809)
1.3.6.1.4.1.318.1.1.13.5.3.31.10INTEGERread-writemandatory
airIRmPmDehumidificHysteresis
OBJECT-TYPE
Dehumidifier hysteresis in tenths of percent relative humidity (6811)
1.3.6.1.4.1.318.1.1.13.5.3.31.12INTEGERread-writemandatory
airIRmPmDehumidificMinWaterTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.31.18
airIRmPmDehumidificMinWaterTempC
OBJECT-TYPE
Dehumidifier minimum water temperature in tenths of degrees Celsius (6817)
1.3.6.1.4.1.318.1.1.13.5.3.31.18.1INTEGERread-writemandatory
airIRmPmDehumidificMinWaterTempF
OBJECT-TYPE
Dehumidifier minimum water temperature in tenths of degrees Fahrenheit (6817)
1.3.6.1.4.1.318.1.1.13.5.3.31.18.2INTEGERread-writemandatory
airIRmPmDehumidificMaxWaterTemp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.31.19
airIRmPmDehumidificMaxWaterTempC
OBJECT-TYPE
Dehumidifier maximum water temperature in tenths of degrees Celsius (6818)
1.3.6.1.4.1.318.1.1.13.5.3.31.19.1INTEGERread-writemandatory
airIRmPmDehumidificMaxWaterTempF
OBJECT-TYPE
Dehumidifier maximum water temperature in tenths of degrees Fahrenheit (6818)
1.3.6.1.4.1.318.1.1.13.5.3.31.19.2INTEGERread-writemandatory
airIRmPmDehumidificRuntime
OBJECT-TYPE
Dehumidifier runtime in hours (6820)
1.3.6.1.4.1.318.1.1.13.5.3.31.21INTEGERread-writemandatory
airIRmPmFan1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.32
airIRmPmFan1ManOpEnable
OBJECT-TYPE
Fan 1 manual operation enable (6901)
1.3.6.1.4.1.318.1.1.13.5.3.32.2AirIRmActivityStateread-onlymandatory
airIRmPmFan1Running
OBJECT-TYPE
Fan 1 running (6902)
1.3.6.1.4.1.318.1.1.13.5.3.32.3AirIRmActivityStateread-onlymandatory
airIRmPmFan1ManOpRunning
OBJECT-TYPE
Fan 1 manual operation running (6905)
1.3.6.1.4.1.318.1.1.13.5.3.32.6AirIRmActivityStateread-onlymandatory
airIRmPmFan1Type
OBJECT-TYPE
Fan 1 type (6908)
1.3.6.1.4.1.318.1.1.13.5.3.32.9INTEGER {direct(1), proportional(2)}read-onlymandatory
airIRmPmFan1Runtime
OBJECT-TYPE
Fan 1 runtime in hours (6931)
1.3.6.1.4.1.318.1.1.13.5.3.32.32INTEGERread-onlymandatory
airIRmPmFan1Speed
OBJECT-TYPE
Fan 1 speed in percent (6932)
1.3.6.1.4.1.318.1.1.13.5.3.32.33INTEGERread-onlymandatory
airIRmPmFan1ManOpSpeed
OBJECT-TYPE
Fan 1 manual operation speed in percent (6933)
1.3.6.1.4.1.318.1.1.13.5.3.32.34INTEGERread-onlymandatory
airIRmPmFan2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.33
airIRmPmFan2ManOpEnable
OBJECT-TYPE
Fan 1 manual operation enable (7001)
1.3.6.1.4.1.318.1.1.13.5.3.33.2AirIRmActivityStateread-onlymandatory
airIRmPmFan2Running
OBJECT-TYPE
Fan 1 running (7002)
1.3.6.1.4.1.318.1.1.13.5.3.33.3AirIRmActivityStateread-onlymandatory
airIRmPmFan2ManOpRunning
OBJECT-TYPE
Fan 1 manual operation running (7005)
1.3.6.1.4.1.318.1.1.13.5.3.33.6AirIRmActivityStateread-onlymandatory
airIRmPmFan2Type
OBJECT-TYPE
Fan 2 type (7008)
1.3.6.1.4.1.318.1.1.13.5.3.33.9INTEGER {direct(1), proportional(2)}read-onlymandatory
airIRmPmFan2Runtime
OBJECT-TYPE
Fan 1 runtime in hours (7031)
1.3.6.1.4.1.318.1.1.13.5.3.33.32INTEGERread-onlymandatory
airIRmPmFan2Speed
OBJECT-TYPE
Fan 1 speed in percent (7032)
1.3.6.1.4.1.318.1.1.13.5.3.33.33INTEGERread-onlymandatory
airIRmPmFan2ManOpSpeed
OBJECT-TYPE
Fan 1 manual operation speed in percent (7033)
1.3.6.1.4.1.318.1.1.13.5.3.33.34INTEGERread-onlymandatory
airIRmPmFan3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.34
airIRmPmFan3ManOpEnable
OBJECT-TYPE
Fan 1 manual operation enable (7101)
1.3.6.1.4.1.318.1.1.13.5.3.34.2AirIRmActivityStateread-onlymandatory
airIRmPmFan3Running
OBJECT-TYPE
Fan 1 running (7102)
1.3.6.1.4.1.318.1.1.13.5.3.34.3AirIRmActivityStateread-onlymandatory
airIRmPmFan3ManOpRunning
OBJECT-TYPE
Fan 1 manual operation running (7105)
1.3.6.1.4.1.318.1.1.13.5.3.34.6AirIRmActivityStateread-onlymandatory
airIRmPmFan3Type
OBJECT-TYPE
Fan 3 type (7108)
1.3.6.1.4.1.318.1.1.13.5.3.34.9INTEGER {direct(1), proportional(2)}read-onlymandatory
airIRmPmFan3Runtime
OBJECT-TYPE
Fan 1 runtime in hours (7131)
1.3.6.1.4.1.318.1.1.13.5.3.34.32INTEGERread-onlymandatory
airIRmPmFan3Speed
OBJECT-TYPE
Fan 1 speed in percent (7132)
1.3.6.1.4.1.318.1.1.13.5.3.34.33INTEGERread-onlymandatory
airIRmPmFan3ManOpSpeed
OBJECT-TYPE
Fan 1 manual operation speed in percent (7133)
1.3.6.1.4.1.318.1.1.13.5.3.34.34INTEGERread-onlymandatory
airIRmPmLouver1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.35
airIRmPmLouver1ManOpEnable
OBJECT-TYPE
Louver 1 manual operation enable (7201)
1.3.6.1.4.1.318.1.1.13.5.3.35.2AirIRmActivityStateread-onlymandatory
airIRmPmLouver1Position
OBJECT-TYPE
Louver 1 position (7202)
1.3.6.1.4.1.318.1.1.13.5.3.35.3INTEGER {closed(1), open(2)}read-onlymandatory
airIRmPmLouver1ManOpPosition
OBJECT-TYPE
Louver 1 manual operation position setting (7203)
1.3.6.1.4.1.318.1.1.13.5.3.35.4INTEGER {closed(1), open(2)}read-onlymandatory
airIRmPmLouver2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.36
airIRmPmLouver2ManOpEnable
OBJECT-TYPE
Louver 2 manual operation enable (7301)
1.3.6.1.4.1.318.1.1.13.5.3.36.2AirIRmActivityStateread-onlymandatory
airIRmPmLouver2Position
OBJECT-TYPE
Louver 2 position (7302)
1.3.6.1.4.1.318.1.1.13.5.3.36.3INTEGER {closed(1), open(2)}read-onlymandatory
airIRmPmLouver2ManOpPosition
OBJECT-TYPE
Louver 2 manual operation position setting (7303)
1.3.6.1.4.1.318.1.1.13.5.3.36.4INTEGER {closed(1), open(2)}read-onlymandatory
airIRmPmLouver3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.37
airIRmPmLouver3ManOpEnable
OBJECT-TYPE
Louver 3 manual operation enable (7401)
1.3.6.1.4.1.318.1.1.13.5.3.37.2AirIRmActivityStateread-onlymandatory
airIRmPmLouver3Position
OBJECT-TYPE
Louver 3 position (7402)
1.3.6.1.4.1.318.1.1.13.5.3.37.3INTEGER {closed(1), open(2)}read-onlymandatory
airIRmPmLouver3ManOpPosition
OBJECT-TYPE
Louver 3 manual operation position setting (7403)
1.3.6.1.4.1.318.1.1.13.5.3.37.4INTEGER {closed(1), open(2)}read-onlymandatory
airIRmPmAuxAlarm1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.38
airIRmPmAuxAlarm2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.39
airIRmPmAuxAlarm3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.40
airIRmPmAuxAlarm4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.41
airIRmPmAuxAlarm5
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.42
airIRmPmAlarmBits
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.43
airIRmPmFan1Failure
OBJECT-TYPE
Fan #1 failure (8500).
1.3.6.1.4.1.318.1.1.13.5.3.43.1AirIRmAlarmStateread-onlymandatory
airIRmPmFan2Failure
OBJECT-TYPE
Fan #2 failure (8501).
1.3.6.1.4.1.318.1.1.13.5.3.43.2AirIRmAlarmStateread-onlymandatory
airIRmPmFan3Failure
OBJECT-TYPE
Fan #3 failure (8502).
1.3.6.1.4.1.318.1.1.13.5.3.43.3AirIRmAlarmStateread-onlymandatory
airIRmPmCompressor1Failure
OBJECT-TYPE
Compressor #1 failure (8503).
1.3.6.1.4.1.318.1.1.13.5.3.43.4AirIRmAlarmStateread-onlymandatory
airIRmPmCompressor2Failure
OBJECT-TYPE
Compressor #2 failure (8504).
1.3.6.1.4.1.318.1.1.13.5.3.43.5AirIRmAlarmStateread-onlymandatory
airIRmPmWaterDetector
OBJECT-TYPE
Water detector alarm (8505).
1.3.6.1.4.1.318.1.1.13.5.3.43.6AirIRmAlarmStateread-onlymandatory
airIRmPmPhaseFailure
OBJECT-TYPE
Phase failure (8506).
1.3.6.1.4.1.318.1.1.13.5.3.43.7AirIRmAlarmStateread-onlymandatory
airIRmPmFireSmokeDetector
OBJECT-TYPE
Fire/smoke detector (8507).
1.3.6.1.4.1.318.1.1.13.5.3.43.8AirIRmAlarmStateread-onlymandatory
airIRmPmReturnAirTemperatureTooHigh
OBJECT-TYPE
Return air temperature too high (8508).
1.3.6.1.4.1.318.1.1.13.5.3.43.9AirIRmAlarmStateread-onlymandatory
airIRmPmReturnAirHumidityTooHigh
OBJECT-TYPE
Return air humidity too high (8509).
1.3.6.1.4.1.318.1.1.13.5.3.43.10AirIRmAlarmStateread-onlymandatory
airIRmPmSupplyAirTemperatureTooHigh
OBJECT-TYPE
Supply air temperature too high (8510).
1.3.6.1.4.1.318.1.1.13.5.3.43.11AirIRmAlarmStateread-onlymandatory
airIRmPmSupplyAirHumidityTooHigh
OBJECT-TYPE
Supply air humidity too high (8511).
1.3.6.1.4.1.318.1.1.13.5.3.43.12AirIRmAlarmStateread-onlymandatory
airIRmPmWaterTemperatureTooHigh
OBJECT-TYPE
Water temperature too high (8512).
1.3.6.1.4.1.318.1.1.13.5.3.43.13AirIRmAlarmStateread-onlymandatory
airIRmPmReturnAirTemperatureTooLow
OBJECT-TYPE
Return air temperature too low (8513).
1.3.6.1.4.1.318.1.1.13.5.3.43.14AirIRmAlarmStateread-onlymandatory
airIRmPmReturnAirHumidityTooLow
OBJECT-TYPE
Return air humidity too low (8514).
1.3.6.1.4.1.318.1.1.13.5.3.43.15AirIRmAlarmStateread-onlymandatory
airIRmPmSupplyAirTemperatureTooLow
OBJECT-TYPE
Supply air temperature too low (8515).
1.3.6.1.4.1.318.1.1.13.5.3.43.16AirIRmAlarmStateread-onlymandatory
airIRmPmSupplyAirHumidityTooLow
OBJECT-TYPE
Supply air humidity too low (8516).
1.3.6.1.4.1.318.1.1.13.5.3.43.17AirIRmAlarmStateread-onlymandatory
airIRmPmWaterTemperatureTooLow
OBJECT-TYPE
Water temperature too low (8517).
1.3.6.1.4.1.318.1.1.13.5.3.43.18AirIRmAlarmStateread-onlymandatory
airIRmPmSensor1Failure
OBJECT-TYPE
Sensor #1 failure (8518).
1.3.6.1.4.1.318.1.1.13.5.3.43.19AirIRmAlarmStateread-onlymandatory
airIRmPmSensor2Failure
OBJECT-TYPE
Sensor #2 failure (8519).
1.3.6.1.4.1.318.1.1.13.5.3.43.20AirIRmAlarmStateread-onlymandatory
airIRmPmSensor3Failure
OBJECT-TYPE
Sensor #3 failure (8520).
1.3.6.1.4.1.318.1.1.13.5.3.43.21AirIRmAlarmStateread-onlymandatory
airIRmPmSensor4Failure
OBJECT-TYPE
Sensor #4 failure (8521).
1.3.6.1.4.1.318.1.1.13.5.3.43.22AirIRmAlarmStateread-onlymandatory
airIRmPmSensor5Failure
OBJECT-TYPE
Sensor #5 failure (8522).
1.3.6.1.4.1.318.1.1.13.5.3.43.23AirIRmAlarmStateread-onlymandatory
airIRmPmSensor6Failure
OBJECT-TYPE
Sensor #6 failure (8523).
1.3.6.1.4.1.318.1.1.13.5.3.43.24AirIRmAlarmStateread-onlymandatory
airIRmPmSensor7Failure
OBJECT-TYPE
Sensor #7 failure (8524).
1.3.6.1.4.1.318.1.1.13.5.3.43.25AirIRmAlarmStateread-onlymandatory
airIRmPmSensor8Failure
OBJECT-TYPE
Sensor #8 failure (8525).
1.3.6.1.4.1.318.1.1.13.5.3.43.26AirIRmAlarmStateread-onlymandatory
airIRmPmSensor9Failure
OBJECT-TYPE
Sensor #9 failure (8526).
1.3.6.1.4.1.318.1.1.13.5.3.43.27AirIRmAlarmStateread-onlymandatory
airIRmPmSensor10Failure
OBJECT-TYPE
Sensor #10 failure (8527).
1.3.6.1.4.1.318.1.1.13.5.3.43.28AirIRmAlarmStateread-onlymandatory
airIRmPmSensor11Failure
OBJECT-TYPE
Sensor #11 failure (8528).
1.3.6.1.4.1.318.1.1.13.5.3.43.29AirIRmAlarmStateread-onlymandatory
airIRmPmSensor12Failure
OBJECT-TYPE
Sensor #12 failure (8529).
1.3.6.1.4.1.318.1.1.13.5.3.43.30AirIRmAlarmStateread-onlymandatory
airIRmPmSensor13Failure
OBJECT-TYPE
Sensor #13 failure (8530).
1.3.6.1.4.1.318.1.1.13.5.3.43.31AirIRmAlarmStateread-onlymandatory
airIRmPmSensor14Failure
OBJECT-TYPE
Sensor #14 failure (8531).
1.3.6.1.4.1.318.1.1.13.5.3.43.32AirIRmAlarmStateread-onlymandatory
airIRmPmSensor15Failure
OBJECT-TYPE
Sensor #15 failure (8532).
1.3.6.1.4.1.318.1.1.13.5.3.43.33AirIRmAlarmStateread-onlymandatory
airIRmPmSensor16Failure
OBJECT-TYPE
Sensor #16 failure (8533).
1.3.6.1.4.1.318.1.1.13.5.3.43.34AirIRmAlarmStateread-onlymandatory
airIRmPmSensor17Failure
OBJECT-TYPE
Sensor #17 failure (8534).
1.3.6.1.4.1.318.1.1.13.5.3.43.35AirIRmAlarmStateread-onlymandatory
airIRmPmSensor18Failure
OBJECT-TYPE
Sensor #18 failure (8535).
1.3.6.1.4.1.318.1.1.13.5.3.43.36AirIRmAlarmStateread-onlymandatory
airIRmPmSensor19Failure
OBJECT-TYPE
Sensor #19 failure (8536).
1.3.6.1.4.1.318.1.1.13.5.3.43.37AirIRmAlarmStateread-onlymandatory
airIRmPmSensor20Failure
OBJECT-TYPE
Sensor #20 failure (8537).
1.3.6.1.4.1.318.1.1.13.5.3.43.38AirIRmAlarmStateread-onlymandatory
airIRmPmSensor21Failure
OBJECT-TYPE
Sensor #21 failure (8538).
1.3.6.1.4.1.318.1.1.13.5.3.43.39AirIRmAlarmStateread-onlymandatory
airIRmPmSensor1Defect
OBJECT-TYPE
Sensor #1 defect (8539).
1.3.6.1.4.1.318.1.1.13.5.3.43.40AirIRmAlarmStateread-onlymandatory
airIRmPmSensor2Defect
OBJECT-TYPE
Sensor #2 defect (8540).
1.3.6.1.4.1.318.1.1.13.5.3.43.41AirIRmAlarmStateread-onlymandatory
airIRmPmSensor3Defect
OBJECT-TYPE
Sensor #3 defect (8541).
1.3.6.1.4.1.318.1.1.13.5.3.43.42AirIRmAlarmStateread-onlymandatory
airIRmPmSensor4Defect
OBJECT-TYPE
Sensor #4 defect (8542).
1.3.6.1.4.1.318.1.1.13.5.3.43.43AirIRmAlarmStateread-onlymandatory
airIRmPmSensor5Defect
OBJECT-TYPE
Sensor #5 defect (8543).
1.3.6.1.4.1.318.1.1.13.5.3.43.44AirIRmAlarmStateread-onlymandatory
airIRmPmSensor6Defect
OBJECT-TYPE
Sensor #6 defect (8544).
1.3.6.1.4.1.318.1.1.13.5.3.43.45AirIRmAlarmStateread-onlymandatory
airIRmPmSensor7Defect
OBJECT-TYPE
Sensor #7 defect (8545).
1.3.6.1.4.1.318.1.1.13.5.3.43.46AirIRmAlarmStateread-onlymandatory
airIRmPmSensor8Defect
OBJECT-TYPE
Sensor #8 defect (8546).
1.3.6.1.4.1.318.1.1.13.5.3.43.47AirIRmAlarmStateread-onlymandatory
airIRmPmSensor9Defect
OBJECT-TYPE
Sensor #9 defect (8547).
1.3.6.1.4.1.318.1.1.13.5.3.43.48AirIRmAlarmStateread-onlymandatory
airIRmPmSensor10Defect
OBJECT-TYPE
Sensor #10 defect (8548).
1.3.6.1.4.1.318.1.1.13.5.3.43.49AirIRmAlarmStateread-onlymandatory
airIRmPmSensor11Defect
OBJECT-TYPE
Sensor #11 defect (8549).
1.3.6.1.4.1.318.1.1.13.5.3.43.50AirIRmAlarmStateread-onlymandatory
airIRmPmSensor12Defect
OBJECT-TYPE
Sensor #12 defect (8550).
1.3.6.1.4.1.318.1.1.13.5.3.43.51AirIRmAlarmStateread-onlymandatory
airIRmPmSensor13Defect
OBJECT-TYPE
Sensor #13 defect (8551).
1.3.6.1.4.1.318.1.1.13.5.3.43.52AirIRmAlarmStateread-onlymandatory
airIRmPmSensor14Defect
OBJECT-TYPE
Sensor #14 defect (8552).
1.3.6.1.4.1.318.1.1.13.5.3.43.53AirIRmAlarmStateread-onlymandatory
airIRmPmSensor15Defect
OBJECT-TYPE
Sensor #15 defect (8553).
1.3.6.1.4.1.318.1.1.13.5.3.43.54AirIRmAlarmStateread-onlymandatory
airIRmPmSensor16Defect
OBJECT-TYPE
Sensor #16 defect (8554).
1.3.6.1.4.1.318.1.1.13.5.3.43.55AirIRmAlarmStateread-onlymandatory
airIRmPmSensor17Defect
OBJECT-TYPE
Sensor #17 defect (8555).
1.3.6.1.4.1.318.1.1.13.5.3.43.56AirIRmAlarmStateread-onlymandatory
airIRmPmSensor18Defect
OBJECT-TYPE
Sensor #18 defect (8556)
1.3.6.1.4.1.318.1.1.13.5.3.43.57AirIRmAlarmStateread-onlymandatory
airIRmPmSensor19Defect
OBJECT-TYPE
Sensor #19 defect (8557).
1.3.6.1.4.1.318.1.1.13.5.3.43.58AirIRmAlarmStateread-onlymandatory
airIRmPmSensor20Defect
OBJECT-TYPE
Sensor #20 defect (8558).
1.3.6.1.4.1.318.1.1.13.5.3.43.59AirIRmAlarmStateread-onlymandatory
airIRmPmSensor21Defect
OBJECT-TYPE
Sensor #21 defect (8559).
1.3.6.1.4.1.318.1.1.13.5.3.43.60AirIRmAlarmStateread-onlymandatory
airIRmPmCompressor1Alarm
OBJECT-TYPE
Compressor #1 alarm (8560).
1.3.6.1.4.1.318.1.1.13.5.3.43.61AirIRmAlarmStateread-onlymandatory
airIRmPmCompressor2Alarm
OBJECT-TYPE
Compressor #2 alarm (8561).
1.3.6.1.4.1.318.1.1.13.5.3.43.62AirIRmAlarmStateread-onlymandatory
airIRmPmCompressor1LowPressure
OBJECT-TYPE
Compressor #1 low pressure (8562).
1.3.6.1.4.1.318.1.1.13.5.3.43.63AirIRmAlarmStateread-onlymandatory
airIRmPmCompressor2LowPressure
OBJECT-TYPE
Compressor #2 low pressure (8563).
1.3.6.1.4.1.318.1.1.13.5.3.43.64AirIRmAlarmStateread-onlymandatory
airIRmPmReheat1Failure
OBJECT-TYPE
Reheat #1 failure (8564).
1.3.6.1.4.1.318.1.1.13.5.3.43.65AirIRmAlarmStateread-onlymandatory
airIRmPmReheat2Failure
OBJECT-TYPE
Reheat #2 failure (8565).
1.3.6.1.4.1.318.1.1.13.5.3.43.66AirIRmAlarmStateread-onlymandatory
airIRmPmReheat3Failure
OBJECT-TYPE
Reheat #3 failure (8566).
1.3.6.1.4.1.318.1.1.13.5.3.43.67AirIRmAlarmStateread-onlymandatory
airIRmPmReheat4Failure
OBJECT-TYPE
Reheat #4 failure (8567).
1.3.6.1.4.1.318.1.1.13.5.3.43.68AirIRmAlarmStateread-onlymandatory
airIRmPmDrycooler1Failure
OBJECT-TYPE
Drycooler #1 failure (8568).
1.3.6.1.4.1.318.1.1.13.5.3.43.69AirIRmAlarmStateread-onlymandatory
airIRmPmDrycooler2Failure
OBJECT-TYPE
Drycooler #2 failure (8569).
1.3.6.1.4.1.318.1.1.13.5.3.43.70AirIRmAlarmStateread-onlymandatory
airIRmPmDrycooler3Failure
OBJECT-TYPE
Drycooler #3 failure (8570).
1.3.6.1.4.1.318.1.1.13.5.3.43.71AirIRmAlarmStateread-onlymandatory
airIRmPmDrycooler4Failure
OBJECT-TYPE
Drycooler #4 failure (8571).
1.3.6.1.4.1.318.1.1.13.5.3.43.72AirIRmAlarmStateread-onlymandatory
airIRmPmPump1Failure
OBJECT-TYPE
Pump #1 failure (8572).
1.3.6.1.4.1.318.1.1.13.5.3.43.73AirIRmAlarmStateread-onlymandatory
airIRmPmPump2Failure
OBJECT-TYPE
Pump #2 failure (8573).
1.3.6.1.4.1.318.1.1.13.5.3.43.74AirIRmAlarmStateread-onlymandatory
airIRmPmPump3Failure
OBJECT-TYPE
Pump #3 failure (8574).
1.3.6.1.4.1.318.1.1.13.5.3.43.75AirIRmAlarmStateread-onlymandatory
airIRmPmPump4Failure
OBJECT-TYPE
Pump #4 failure (8575).
1.3.6.1.4.1.318.1.1.13.5.3.43.76AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier1Failure
OBJECT-TYPE
Humidifier #1 failure (8576).
1.3.6.1.4.1.318.1.1.13.5.3.43.77AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier2Failure
OBJECT-TYPE
Humidifier #2 failure (8577).
1.3.6.1.4.1.318.1.1.13.5.3.43.78AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier3Failure
OBJECT-TYPE
Humidifier #3 failure (8578).
1.3.6.1.4.1.318.1.1.13.5.3.43.79AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier1Alarm5us
OBJECT-TYPE
Humidifier #1 5us alarm (8579).
1.3.6.1.4.1.318.1.1.13.5.3.43.80AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier2Alarm5us
OBJECT-TYPE
Humidifier #2 5us alarm (8580).
1.3.6.1.4.1.318.1.1.13.5.3.43.81AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier3Alarm5us
OBJECT-TYPE
Humidifier #3 5us alarm (8581).
1.3.6.1.4.1.318.1.1.13.5.3.43.82AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier1Alarm20us
OBJECT-TYPE
Humidifier #1 20us alarm (8582).
1.3.6.1.4.1.318.1.1.13.5.3.43.83AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier2Alarm20us
OBJECT-TYPE
Humidifier #2 20us alarm (8583).
1.3.6.1.4.1.318.1.1.13.5.3.43.84AirIRmAlarmStateread-onlymandatory
airIRmPmHumidifier3Alarm20us
OBJECT-TYPE
Humidifier #3 20us alarm (8584).
1.3.6.1.4.1.318.1.1.13.5.3.43.85AirIRmAlarmStateread-onlymandatory
airIRmPmFan1Alarm
OBJECT-TYPE
Fan #1 alarm (8585).
1.3.6.1.4.1.318.1.1.13.5.3.43.86AirIRmAlarmStateread-onlymandatory
airIRmPmFan2Alarm
OBJECT-TYPE
Fan #2 alarm (8586).
1.3.6.1.4.1.318.1.1.13.5.3.43.87AirIRmAlarmStateread-onlymandatory
airIRmPmFan3Alarm
OBJECT-TYPE
Fan #3 alarm (8587).
1.3.6.1.4.1.318.1.1.13.5.3.43.88AirIRmAlarmStateread-onlymandatory
airIRmPmFilter1Clogged
OBJECT-TYPE
Filter #1 clogged (8588).
1.3.6.1.4.1.318.1.1.13.5.3.43.89AirIRmAlarmStateread-onlymandatory
airIRmPmFilter2Clogged
OBJECT-TYPE
Filter #2 clogged (8589).
1.3.6.1.4.1.318.1.1.13.5.3.43.90AirIRmAlarmStateread-onlymandatory
airIRmPmFilter3Clogged
OBJECT-TYPE
Filter #3 clogged (8590).
1.3.6.1.4.1.318.1.1.13.5.3.43.91AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm1
OBJECT-TYPE
Auxiliary #1 alarm (8591).
1.3.6.1.4.1.318.1.1.13.5.3.43.92AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm2
OBJECT-TYPE
Auxiliary #2 alarm (8592).
1.3.6.1.4.1.318.1.1.13.5.3.43.93AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm3
OBJECT-TYPE
Auxiliary #3 alarm (8593).
1.3.6.1.4.1.318.1.1.13.5.3.43.94AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm4
OBJECT-TYPE
Auxiliary #4 alarm (8594).
1.3.6.1.4.1.318.1.1.13.5.3.43.95AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm5
OBJECT-TYPE
Auxiliary #5 alarm (8595).
1.3.6.1.4.1.318.1.1.13.5.3.43.96AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm6
OBJECT-TYPE
Auxiliary #6 alarm (8596).
1.3.6.1.4.1.318.1.1.13.5.3.43.97AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm7
OBJECT-TYPE
Auxiliary #7 alarm (8597).
1.3.6.1.4.1.318.1.1.13.5.3.43.98AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm8
OBJECT-TYPE
Auxiliary #8 alarm (8598).
1.3.6.1.4.1.318.1.1.13.5.3.43.99AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm9
OBJECT-TYPE
Auxiliary #9 alarm (8599).
1.3.6.1.4.1.318.1.1.13.5.3.43.100AirIRmAlarmStateread-onlymandatory
airIRmPmAuxiliaryAlarm10
OBJECT-TYPE
Auxiliary #10 alarm (8600).
1.3.6.1.4.1.318.1.1.13.5.3.43.101AirIRmAlarmStateread-onlymandatory
airIRmPmHotGasHeatingAlarm
OBJECT-TYPE
Hot gas heating alarm (8601).
1.3.6.1.4.1.318.1.1.13.5.3.43.102AirIRmAlarmStateread-onlymandatory
airIRmPmEEV1PressureSensorError
OBJECT-TYPE
EEV1 pressure sensor error (8602).
1.3.6.1.4.1.318.1.1.13.5.3.43.103AirIRmAlarmStateread-onlymandatory
airIRmPmEEV1TemperatureSensorError
OBJECT-TYPE
EEV1 temperature sensor error (8603).
1.3.6.1.4.1.318.1.1.13.5.3.43.104AirIRmAlarmStateread-onlymandatory
airIRmPmEEV1StepperMotorError
OBJECT-TYPE
EEV1 stepper motor error (8604).
1.3.6.1.4.1.318.1.1.13.5.3.43.105AirIRmAlarmStateread-onlymandatory
airIRmPmEEV2PressureSensorError
OBJECT-TYPE
EEV2 pressure sensor error (8605).
1.3.6.1.4.1.318.1.1.13.5.3.43.106AirIRmAlarmStateread-onlymandatory
airIRmPmEEV2TemperatureSensorError
OBJECT-TYPE
EEV2 temperature sensor error (8606).
1.3.6.1.4.1.318.1.1.13.5.3.43.107AirIRmAlarmStateread-onlymandatory
airIRmPmEEV2StepperMotorError
OBJECT-TYPE
EEV2 stepper motor error (8607).
1.3.6.1.4.1.318.1.1.13.5.3.43.108AirIRmAlarmStateread-onlymandatory
airIRmPmMyZone
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.44
airIRmPmMyZoneNumber
OBJECT-TYPE
My zone number (11700).
1.3.6.1.4.1.318.1.1.13.5.3.44.1INTEGERread-onlymandatory
airIRmPmMyZoneRoomTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.44.2
airIRmPmMyZoneRoomTemperatureC
OBJECT-TYPE
My zone room temperature in tenths of degrees Celsius (11701).
1.3.6.1.4.1.318.1.1.13.5.3.44.2.1INTEGERread-onlymandatory
airIRmPmMyZoneRoomTemperatureF
OBJECT-TYPE
My zone room temperature in tenths of degrees Fahrenheit (11701).
1.3.6.1.4.1.318.1.1.13.5.3.44.2.2INTEGERread-onlymandatory
airIRmPmMyZoneRoomHumidity
OBJECT-TYPE
My zone room humidity in tenths of %RH (11702).
1.3.6.1.4.1.318.1.1.13.5.3.44.3INTEGERread-onlymandatory
airIRmPmMyZoneSupplyTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.44.4
airIRmPmMyZoneSupplyTemperatureC
OBJECT-TYPE
My zone supply temperature in tenths of degrees Celsius (11703).
1.3.6.1.4.1.318.1.1.13.5.3.44.4.1INTEGERread-onlymandatory
airIRmPmMyZoneSupplyTemperatureF
OBJECT-TYPE
My zone supply temperature in tenths of degrees Fahrenheit (11703).
1.3.6.1.4.1.318.1.1.13.5.3.44.4.2INTEGERread-onlymandatory
airIRmPmMyZoneSupplyHumidity
OBJECT-TYPE
My zone supply humidity in tenths of %RH (11704).
1.3.6.1.4.1.318.1.1.13.5.3.44.5INTEGERread-onlymandatory
airIRmPmMyZoneSequencingTime
OBJECT-TYPE
My zone sequencing time in minutes (11705).
1.3.6.1.4.1.318.1.1.13.5.3.44.6INTEGERread-onlymandatory
airIRmPmMyZoneNumberOfErrorUnits
OBJECT-TYPE
Number of error units in my zone (11706).
1.3.6.1.4.1.318.1.1.13.5.3.44.7INTEGERread-onlymandatory
airIRmPmMyZoneEmergencyTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.44.8
airIRmPmMyZoneEmergencyTemperatureC
OBJECT-TYPE
My zone emergency temperature in tenths of degrees Celsius (11707).
1.3.6.1.4.1.318.1.1.13.5.3.44.8.1INTEGERread-onlymandatory
airIRmPmMyZoneEmergencyTemperatureF
OBJECT-TYPE
My zone emergency temperature in tenths of degrees Fahrenheit (11707).
1.3.6.1.4.1.318.1.1.13.5.3.44.8.2INTEGERread-onlymandatory
airIRmPmMyZoneCWEnergySaveMode
OBJECT-TYPE
My zone CW energy save mode (11708).
1.3.6.1.4.1.318.1.1.13.5.3.44.9AirIRmActivityStateread-onlymandatory
airIRmPmGlobalZoneData
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.5.3.45
airIRmPmGlobalZoneDataEmergencyOpMode
OBJECT-TYPE
Emergency operation mode (11800).
1.3.6.1.4.1.318.1.1.13.5.3.45.1AirIRmActivityStateread-onlymandatory
airIRGen3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.6
airIRG3Ident
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.6.1
airIRG3IdentTableSize
OBJECT-TYPE
The ident table size.
1.3.6.1.4.1.318.1.1.13.6.1.1INTEGERread-onlymandatory
airIRG3IdentTable
OBJECT-TYPE
Allows to get ident information of current RDU and its assigned CM's.
1.3.6.1.4.1.318.1.1.13.6.1.2not-accessiblemandatory
airIRG3IdentEntry
OBJECT-TYPE
The ident table entry.
1.3.6.1.4.1.318.1.1.13.6.1.2.1not-accessiblemandatory
airIRG3IdentIndex
OBJECT-TYPE
Index of ident table.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.1INTEGERread-onlymandatory
airIRG3IdentName
OBJECT-TYPE
A character string identifying the unit name.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.2DisplayStringread-writemandatory
airIRG3IdentLocation
OBJECT-TYPE
A character string identifying the unit location.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.3DisplayStringread-writemandatory
airIRG3IdentModelNumber
OBJECT-TYPE
A character string identifying the unit model number.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.4DisplayStringread-onlymandatory
airIRG3IdentSerialNumber
OBJECT-TYPE
A character string identifying the unit serial number.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.5DisplayStringread-onlymandatory
airIRG3IdentFirmwareRevision
OBJECT-TYPE
A character string identifying the unit firmware version.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.6DisplayStringread-onlymandatory
airIRG3IdentHardwareRevision
OBJECT-TYPE
A character string identifying the unit controller hardware revision.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.7DisplayStringread-onlymandatory
airIRG3IdentManufactureDate
OBJECT-TYPE
A character string identifying the unit manufacture date.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.8DisplayStringread-onlymandatory
airIRG3IdentRDUSysOID
OBJECT-TYPE
This OID contains an OID path to the RDU data.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.9OBJECT IDENTIFIERread-onlymandatory
airIRG3IdentCMSysOID
OBJECT-TYPE
This OID contains an OID path to the cooling module data.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.10OBJECT IDENTIFIERread-onlymandatory
airIRG3IdentGroupSysOID
OBJECT-TYPE
This OID contains an OID path to the group data.
1.3.6.1.4.1.318.1.1.13.6.1.2.1.11OBJECT IDENTIFIERread-onlymandatory
airIRG3Group
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.6.2
airIRG3GroupTableSize
OBJECT-TYPE
The group table size.
1.3.6.1.4.1.318.1.1.13.6.2.1INTEGERread-onlymandatory
airIRG3GroupStatusTable
OBJECT-TYPE
Allows to get group status information.
1.3.6.1.4.1.318.1.1.13.6.2.2not-accessiblemandatory
airIRG3GroupStatusEntry
OBJECT-TYPE
The group staus table entry.
1.3.6.1.4.1.318.1.1.13.6.2.2.1not-accessiblemandatory
airIRG3GroupStatusIndex
OBJECT-TYPE
Index of group status table.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.1INTEGERread-onlymandatory
airIRG3GroupStatusCoolOutput
OBJECT-TYPE
The group cooling output in tenths of kilowatts (kW). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.2INTEGERread-onlymandatory
airIRG3GroupStatusCoolDemand
OBJECT-TYPE
The group cooling demand in tenths of kilowatts (kW). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.3INTEGERread-onlymandatory
airIRG3GroupStatusAirFlowUS
OBJECT-TYPE
The group air flow in cubic feet per minute (CFM). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.4INTEGERread-onlymandatory
airIRG3GroupStatusAirFlowMetric
OBJECT-TYPE
The group air flow in liters per second (L/s). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.5INTEGERread-onlymandatory
airIRG3GroupStatusMaxRackInletTempUS
OBJECT-TYPE
The group maximum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.6INTEGERread-onlymandatory
airIRG3GroupStatusMaxRackInletTempMetric
OBJECT-TYPE
The group maximum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.7INTEGERread-onlymandatory
airIRG3GroupStatusMinRackInletTempUS
OBJECT-TYPE
The group minimum rack inlet temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.8INTEGERread-onlymandatory
airIRG3GroupStatusMinRackInletTempMetric
OBJECT-TYPE
The group minimum rack inlet temperature in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.9INTEGERread-onlymandatory
airIRG3GroupStatusMaxReturnAirTempUS
OBJECT-TYPE
The group maximum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.10INTEGERread-onlymandatory
airIRG3GroupStatusMaxReturnAirTempMetric
OBJECT-TYPE
The group maximum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.11INTEGERread-onlymandatory
airIRG3GroupStatusMinReturnAirTempUS
OBJECT-TYPE
The group minimum return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.12INTEGERread-onlymandatory
airIRG3GroupStatusMinReturnAirTempMetric
OBJECT-TYPE
The group minimum return air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.13INTEGERread-onlymandatory
airIRG3GroupStatusAvgSupplyTempUS
OBJECT-TYPE
The group average supply air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.14INTEGERread-onlymandatory
airIRG3GroupStatusAvgSupplyTempMetric
OBJECT-TYPE
The group average supply air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.15INTEGERread-onlymandatory
airIRG3GroupStatusAvgReturnTempUS
OBJECT-TYPE
The group average return air temperature in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.16INTEGERread-onlymandatory
airIRG3GroupStatusAvgReturnTempMetric
OBJECT-TYPE
The group average return air temperature in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.17INTEGERread-onlymandatory
airIRG3GroupStatusAvgFanSpeed
OBJECT-TYPE
The group average fan speed in revolutions per minute (RPM). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.18INTEGERread-onlymandatory
airIRG3GroupStatusAvgAirFlowUS
OBJECT-TYPE
The group average air flow in cubic feet per minute (CFM). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.19INTEGERread-onlymandatory
airIRG3GroupStatusAvgAirFlowMetric
OBJECT-TYPE
The group average air flow in liters per second (L/s). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.20INTEGERread-onlymandatory
airIRG3GroupStatusTotalAirFlowUS
OBJECT-TYPE
The group total air flow in cubic feet per minute (CFM). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.21INTEGERread-onlymandatory
airIRG3GroupStatusTotalAirFlowMetric
OBJECT-TYPE
The group total air flow in liters per second (L/s). Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.2.1.22INTEGERread-onlymandatory
airIRG3GroupSetpointsTable
OBJECT-TYPE
Allows to access the group setpoints.
1.3.6.1.4.1.318.1.1.13.6.2.3not-accessiblemandatory
airIRG3GroupSetpointsEntry
OBJECT-TYPE
The group setpoints table entry.
1.3.6.1.4.1.318.1.1.13.6.2.3.1not-accessiblemandatory
airIRG3GroupSetpointsIndex
OBJECT-TYPE
Index of group setpoints table.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.1INTEGERread-onlymandatory
airIRG3GroupSetpointsCoolSetpointUS
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.2INTEGERread-writemandatory
airIRG3GroupSetpointsCoolSetpointMetric
OBJECT-TYPE
Group cooling setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.3INTEGERread-writemandatory
airIRG3GroupSetpointsCoolDeadbandUS
OBJECT-TYPE
Group cooling deadband in tenths of degrees Fahrenheit. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.4INTEGERread-writemandatory
airIRG3GroupSetpointsCoolDeadbandMetric
OBJECT-TYPE
Group cooling deadband in tenths of degrees Celsius. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.5INTEGERread-writemandatory
airIRG3GroupSetpointsFanSpeedPreference
OBJECT-TYPE
The group preferred fan speed setting.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.6INTEGER {low(1), med-low(2), med(3), med-high(4), high(5)}read-writemandatory
airIRG3GroupSetpointsSupplyAirSetpointUS
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.7INTEGERread-writemandatory
airIRG3GroupSetpointsSupplyAirSetpointMetric
OBJECT-TYPE
Group supply air setpoint in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.8INTEGERread-writemandatory
airIRG3GroupSetpointsAirFlowControl
OBJECT-TYPE
The group air flow control.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.9INTEGER {automatic(1), manual(2)}read-writemandatory
airIRG3GroupSetpointsLightingOnTime
OBJECT-TYPE
The group lighting on time in minutes.
1.3.6.1.4.1.318.1.1.13.6.2.3.1.10INTEGERread-writemandatory
airIRG3GroupConfigTable
OBJECT-TYPE
Allows to access group configuration table.
1.3.6.1.4.1.318.1.1.13.6.2.4not-accessiblemandatory
airIRG3GroupConfigEntry
OBJECT-TYPE
The group config table entry.
1.3.6.1.4.1.318.1.1.13.6.2.4.1not-accessiblemandatory
airIRG3GroupConfigIndex
OBJECT-TYPE
Index of group config table.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.1INTEGERread-onlymandatory
airIRG3GroupConfigNumberofCoolingUnits
OBJECT-TYPE
The number of cooling units.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.2INTEGERread-writemandatory
airIRG3GroupConfigConfigurationType
OBJECT-TYPE
The group configuration type. The spot configuration type is not supported. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.3INTEGER {racs(1), spot(2), in-row(3), hacs(4)}read-writemandatory
airIRG3GroupConfigCapacityControlType
OBJECT-TYPE
The group capacity control. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.4INTEGER {discrete(1), proportional(2)}read-writemandatory
airIRG3GroupConfigFanSpeedControl
OBJECT-TYPE
The group fan speed control.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.5INTEGER {automatic(1), manual(2)}read-writemandatory
airIRG3GroupConfigCoolGainP
OBJECT-TYPE
The gain component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.6INTEGERread-writemandatory
airIRG3GroupConfigCoolResetRateI
OBJECT-TYPE
The integral component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.7INTEGERread-writemandatory
airIRG3GroupConfigCoolDerivativeD
OBJECT-TYPE
The derivative component of the PID in hundredths.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.8INTEGERread-writemandatory
airIRG3GroupConfigCoolPIDReset
OBJECT-TYPE
Will reset the PID coefficients back to the factory defaults. Readback is not supported, returns -1.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.9INTEGER {readBack(1), reset(2)}read-writemandatory
airIRG3GroupConfigNumberofBackupUnits
OBJECT-TYPE
The number of backup units.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.10INTEGERread-writemandatory
airIRG3GroupConfigRuntimeBalancingEnable
OBJECT-TYPE
Enable or disable runtime balancing feature.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.11INTEGER {disable(1), enable(2)}read-writemandatory
airIRG3GroupConfigLoadAssistEnable
OBJECT-TYPE
Enable or disable load assist feature.
1.3.6.1.4.1.318.1.1.13.6.2.4.1.12INTEGER {disable(1), enable(2)}read-writemandatory
airIRG3Alarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.6.3
airIRG3AlarmsTableSize
OBJECT-TYPE
The number of active alarms in the airIRG3AlarmsTable.
1.3.6.1.4.1.318.1.1.13.6.3.1INTEGERread-onlymandatory
airIRG3AlarmsTable
OBJECT-TYPE
Table of active alarms for the device.
1.3.6.1.4.1.318.1.1.13.6.3.2not-accessiblemandatory
airIRG3AlarmsEntry
OBJECT-TYPE
Alarms specification
1.3.6.1.4.1.318.1.1.13.6.3.2.1not-accessiblemandatory
airIRG3AlarmsIndex
OBJECT-TYPE
Alarm index.
1.3.6.1.4.1.318.1.1.13.6.3.2.1.1INTEGERread-onlymandatory
airIRG3AlarmsEventCode
OBJECT-TYPE
Event Code for the alarm. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.3.2.1.2INTEGERread-onlymandatory
airIRG3AlarmsDescription
OBJECT-TYPE
Description of the alarm. Returns (-1) if not supported.
1.3.6.1.4.1.318.1.1.13.6.3.2.1.3DisplayString (SIZE(0..64))read-onlymandatory
airIRG3RDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.6.4
airIRG3RDUTableSize
OBJECT-TYPE
The RDU table size.
1.3.6.1.4.1.318.1.1.13.6.4.1INTEGERread-onlymandatory
airIRG3RDUStatusTable
OBJECT-TYPE
Allows to access RDU status table.
1.3.6.1.4.1.318.1.1.13.6.4.2not-accessiblemandatory
airIRG3RDUStatusEntry
OBJECT-TYPE
The RDU status table entry.
1.3.6.1.4.1.318.1.1.13.6.4.2.1not-accessiblemandatory
airIRG3RDUStatusDeviceIndex
OBJECT-TYPE
Index of RDU status table.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.1INTEGERread-onlymandatory
airIRG3RDUID
OBJECT-TYPE
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.2DisplayStringread-onlymandatory
airIRG3RDUStatusOnReadyStandby
OBJECT-TYPE
The RDU current status.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.3INTEGER {standby(1), ready(2), on(3)}read-onlymandatory
airIRG3RDUStatusOperatingMode
OBJECT-TYPE
The RDU actual operating mode.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.4INTEGER {standby(1), ready(2), on(3), stop(4), maintenancemode(5)}read-onlymandatory
airIRG3RDUStatusLeadPump
OBJECT-TYPE
The RDU lead pump.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.5INTEGER {pump1(1), pump2(2)}read-onlymandatory
airIRG3RDUStatusStartupDelay
OBJECT-TYPE
The RDU start up delay in seconds.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.6INTEGERread-onlymandatory
airIRG3RDUStatusPumpChangeOverInterval
OBJECT-TYPE
The RDU pump change over interval in days.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.7INTEGERread-onlymandatory
airIRG3RDUStatusStopOnLeakDetect
OBJECT-TYPE
The RDU status of stop on leak detect.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.8INTEGER {no(1), yes(2)}read-onlymandatory
airIRG3RDUStatusPowerSource
OBJECT-TYPE
The RDU power source status.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.9INTEGER {singleFeed(1), dualFeed(2)}read-onlymandatory
airIRG3RDUStatusTotalRDUOutputPower
OBJECT-TYPE
The RDU output power in tenths of kilowatts (kW).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.10INTEGERread-onlymandatory
airIRG3RDUStatusInletWaterTempUS
OBJECT-TYPE
The RDU inlet water temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.11INTEGERread-onlymandatory
airIRG3RDUStatusInletWaterTempMetric
OBJECT-TYPE
The RDU inlet water temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.12INTEGERread-onlymandatory
airIRG3RDUStatusOutletWaterTempUS
OBJECT-TYPE
The RDU outlet water temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.13INTEGERread-onlymandatory
airIRG3RDUStatusOutletWaterTempMetric
OBJECT-TYPE
The RDU outlet water temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.14INTEGERread-onlymandatory
airIRG3RDUStatusCondenserSaturationTempUS
OBJECT-TYPE
The RDU condenser saturation temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.15INTEGERread-onlymandatory
airIRG3RDUStatusCondenserSaturationTempMetric
OBJECT-TYPE
The RDU condenser saturation temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.16INTEGERread-onlymandatory
airIRG3RDUStatusDewPointTempUS
OBJECT-TYPE
The RDU dew point temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.17INTEGERread-onlymandatory
airIRG3RDUStatusDewPointTempMetric
OBJECT-TYPE
The RDU dew point temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.18INTEGERread-onlymandatory
airIRG3RDUStatusPumpOutletTempUS
OBJECT-TYPE
The RDU pump outlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.19INTEGERread-onlymandatory
airIRG3RDUStatusPumpOutletTempMetric
OBJECT-TYPE
The RDU pump outlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.20INTEGERread-onlymandatory
airIRG3RDUStatusSubcoolerOutletTempUS
OBJECT-TYPE
The RDU sub cooler outlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.21INTEGERread-onlymandatory
airIRG3RDUStatusSubcoolerOutletTempMetric
OBJECT-TYPE
The RDU sub cooler outlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.22INTEGERread-onlymandatory
airIRG3RDUStatusCondenserOutletTempUS
OBJECT-TYPE
The RDU condenser outlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.23INTEGERread-onlymandatory
airIRG3RDUStatusCondenserOutletTempMetric
OBJECT-TYPE
The RDU condenser outlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.24INTEGERread-onlymandatory
airIRG3RDUStatusCondenserInletTempUS
OBJECT-TYPE
The RDU condenser inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.25INTEGERread-onlymandatory
airIRG3RDUStatusCondenserInletTempMetric
OBJECT-TYPE
The RDU condenser inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.26INTEGERread-onlymandatory
airIRG3RDUStatusCondenserOutletPressureUS
OBJECT-TYPE
The RDU condenser outlet pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.27INTEGERread-onlymandatory
airIRG3RDUStatusCondenserOutletPressureMetric
OBJECT-TYPE
The RDU condenser outlet pressure in kiloPascals (KPa).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.28INTEGERread-onlymandatory
airIRG3RDUStatusPump1HeadPressureUS
OBJECT-TYPE
The RDU Pump 1 head pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.29INTEGERread-onlymandatory
airIRG3RDUStatusPump1HeadPressureMetric
OBJECT-TYPE
The RDU Pump 1 head pressure in kiloPascals (KPa).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.30INTEGERread-onlymandatory
airIRG3RDUStatusPump2HeadPressureUS
OBJECT-TYPE
The RDU Pump 2 head pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.31INTEGERread-onlymandatory
airIRG3RDUStatusPump2HeadPressureMetric
OBJECT-TYPE
The RDU Pump 2 head pressure in kiloPascals (KPa).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.32INTEGERread-onlymandatory
airIRG3RDUStatusPump1Speed
OBJECT-TYPE
The RDU Pump 1 speed in revolutions per minute (RPM).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.33INTEGERread-onlymandatory
airIRG3RDUStatusPump2Speed
OBJECT-TYPE
The RDU Pump 2 speed in revolutions per minute (RPM).
1.3.6.1.4.1.318.1.1.13.6.4.2.1.34INTEGERread-onlymandatory
airIRG3RDUStatusCWValvePosition
OBJECT-TYPE
The RDU CW Valve position in % open
1.3.6.1.4.1.318.1.1.13.6.4.2.1.35INTEGERread-onlymandatory
airIRG3RDUStatusReceiverLiquidLevel
OBJECT-TYPE
The RDU receiver liquid level in % Full
1.3.6.1.4.1.318.1.1.13.6.4.2.1.36INTEGERread-onlymandatory
airIRG3RDUStatusDCPowerSupply1Current
OBJECT-TYPE
The RDU DC Power Supply 1 Current in Amps
1.3.6.1.4.1.318.1.1.13.6.4.2.1.37INTEGERread-onlymandatory
airIRG3RDUStatusDCPowerSupply2Current
OBJECT-TYPE
The RDU DC Power Supply 2 Current in Amps
1.3.6.1.4.1.318.1.1.13.6.4.2.1.38INTEGERread-onlymandatory
airIRG3RDUStatusTotalDCPowerSupplyCurrent
OBJECT-TYPE
The RDU Total DC Power Supply Current in Amps
1.3.6.1.4.1.318.1.1.13.6.4.2.1.39INTEGERread-onlymandatory
airIRG3RDUStatusInputState
OBJECT-TYPE
The RDU Input state.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.40INTEGER {open(1), closed(2)}read-onlymandatory
airIRG3RDUStatusOutputState
OBJECT-TYPE
The RDU Output state
1.3.6.1.4.1.318.1.1.13.6.4.2.1.41INTEGER {open(1), closed(2)}read-onlymandatory
airIRG3RDUStatusByPassValvePosition
OBJECT-TYPE
The RDU By Pass Valve position in % open
1.3.6.1.4.1.318.1.1.13.6.4.2.1.42INTEGERread-onlymandatory
airIRG3RDUStatusRefrigerantLeakDetector
OBJECT-TYPE
The RDU refrigerant leak detector status.
1.3.6.1.4.1.318.1.1.13.6.4.2.1.43INTEGER {suspended(1), calibrating(2), operating(3), disabled(4)}read-onlymandatory
airIRG3RDURunHoursTable
OBJECT-TYPE
Allows to access RDU run hours table.
1.3.6.1.4.1.318.1.1.13.6.4.3not-accessiblemandatory
airIRG3RDURunHoursEntry
OBJECT-TYPE
The RDU run hours table entry.
1.3.6.1.4.1.318.1.1.13.6.4.3.1not-accessiblemandatory
airIRG3RDURunHoursDeviceIndex
OBJECT-TYPE
Index of RDU run hours table.
1.3.6.1.4.1.318.1.1.13.6.4.3.1.1INTEGERread-onlymandatory
airIRG3RDURunHoursRDUID
OBJECT-TYPE
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
1.3.6.1.4.1.318.1.1.13.6.4.3.1.2DisplayStringread-onlymandatory
airIRG3RDURunHoursPump1
OBJECT-TYPE
The RDU run hours of Pump 1.
1.3.6.1.4.1.318.1.1.13.6.4.3.1.3INTEGERread-onlymandatory
airIRG3RDURunHoursPump2
OBJECT-TYPE
The RDU run hours of Pump 2.
1.3.6.1.4.1.318.1.1.13.6.4.3.1.4INTEGERread-onlymandatory
airIRG3RDURunHoursPowerSupply1
OBJECT-TYPE
The RDU run hours of power supply 1.
1.3.6.1.4.1.318.1.1.13.6.4.3.1.5INTEGERread-onlymandatory
airIRG3RDURunHoursPowerSupply2
OBJECT-TYPE
The RDU run hours of power supply 2.
1.3.6.1.4.1.318.1.1.13.6.4.3.1.6INTEGERread-onlymandatory
airIRG3RDUServiceIntervalsTable
OBJECT-TYPE
Allows to access RDU service intervals table.
1.3.6.1.4.1.318.1.1.13.6.4.4not-accessiblemandatory
airIRG3RDUServiceIntervalsEntry
OBJECT-TYPE
The service interval table entry.
1.3.6.1.4.1.318.1.1.13.6.4.4.1not-accessiblemandatory
airIRG3RDUServiceIntervalsDeviceIndex
OBJECT-TYPE
Index of service interval table.
1.3.6.1.4.1.318.1.1.13.6.4.4.1.1INTEGERread-onlymandatory
airIRG3RDUServiceIntervalsRDUID
OBJECT-TYPE
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
1.3.6.1.4.1.318.1.1.13.6.4.4.1.2DisplayStringread-onlymandatory
airIRG3RDUServiceIntervalsAirFilterInterval
OBJECT-TYPE
The RDU service interval for air filter in hours. Returns -1 if not supported.
1.3.6.1.4.1.318.1.1.13.6.4.4.1.3INTEGERread-writemandatory
airIRG3RDUServiceIntervalsAirFilterAlarm
OBJECT-TYPE
The RDU service interval air filter alarm status. Returns -1 if not supported.
1.3.6.1.4.1.318.1.1.13.6.4.4.1.4INTEGER {enable(1), disable(2)}read-writemandatory
airIRG3RDUThresholdsTable
OBJECT-TYPE
Allows to access RDU thresholds table.
1.3.6.1.4.1.318.1.1.13.6.4.5not-accessiblemandatory
airIRG3RDUThresholdsEntry
OBJECT-TYPE
The RDU thresholds table entry.
1.3.6.1.4.1.318.1.1.13.6.4.5.1not-accessiblemandatory
airIRG3RDUThresholdsDeviceIndex
OBJECT-TYPE
Index of RDU thresholds table.
1.3.6.1.4.1.318.1.1.13.6.4.5.1.1INTEGERread-onlymandatory
airIRG3RDUThresholdsRDUID
OBJECT-TYPE
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
1.3.6.1.4.1.318.1.1.13.6.4.5.1.2DisplayStringread-onlymandatory
airIRG3RDUThresholdsEnteringFluidTempHighUS
OBJECT-TYPE
The RDU threshold for entering fluid temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.4.5.1.3INTEGERread-writemandatory
airIRG3RDUThresholdsEnteringFluidTempHighMetric
OBJECT-TYPE
The RDU threshold for entering fluid temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.4.5.1.4INTEGERread-writemandatory
airIRG3RDUSetpointsTable
OBJECT-TYPE
Allows to access RDU set points table.
1.3.6.1.4.1.318.1.1.13.6.4.6not-accessiblemandatory
airIRG3RDUSetpointsEntry
OBJECT-TYPE
The RDU set points table entry.
1.3.6.1.4.1.318.1.1.13.6.4.6.1not-accessiblemandatory
airIRG3RDUSetpointsDeviceIndex
OBJECT-TYPE
Index of RDU set points table.
1.3.6.1.4.1.318.1.1.13.6.4.6.1.1INTEGERread-onlymandatory
airIRG3RDUConfigTable
OBJECT-TYPE
Allows to access RDU configuration table.
1.3.6.1.4.1.318.1.1.13.6.4.7not-accessiblemandatory
airIRG3RDUConfigEntry
OBJECT-TYPE
The RDU configuration table entry.
1.3.6.1.4.1.318.1.1.13.6.4.7.1not-accessiblemandatory
airIRG3RDUConfigDeviceIndex
OBJECT-TYPE
Index of RDU configuration table.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.1INTEGERread-onlymandatory
airIRG3RDUConfigRDUID
OBJECT-TYPE
The current RDU ID (1 to F). Configured RDU only shall display ID, else return -1.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.2DisplayStringread-onlymandatory
airIRG3RDUConfigStopOnLeakDetect
OBJECT-TYPE
The RDU stop on leak detect set.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.3INTEGER {no(1), yes(2)}read-writemandatory
airIRG3RDUConfigStartupDelay
OBJECT-TYPE
The RDU start up delay in seconds.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.4INTEGERread-writemandatory
airIRG3RDUConfigPumpChangeOverInterval
OBJECT-TYPE
The RDU pump change over interval in days.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.5INTEGERread-writemandatory
airIRG3RDUConfigPowerSource
OBJECT-TYPE
The RDU power source.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.6INTEGER {singleFeed(1), dualFeed(2)}read-writemandatory
airIRG3RDUConfigOutputSource
OBJECT-TYPE
The RDU output source.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.7INTEGER {anyalarm(1), onlycriticalalarms(2)}read-writemandatory
airIRG3RDUConfigInputNormalState
OBJECT-TYPE
The RDU Input Normal State.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.8INTEGER {open(1), closed(2)}read-writemandatory
airIRG3RDUConfigOutputNormalState
OBJECT-TYPE
The RDU Output Normal State.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.9INTEGER {open(1), closed(2)}read-writemandatory
airIRG3RDUConfigByPassValveEnabled
OBJECT-TYPE
The RDU By Pass Valve Enabled State.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.10INTEGER {no(1), yes(2)}read-writemandatory
airIRG3RDUConfigRefrigerantLeakDetectorEnabled
OBJECT-TYPE
The RDU Refrigerant Leak Detector Enabled State.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.11INTEGER {no(1), yes(2)}read-writemandatory
airIRG3RDUConfigCalibrateRefrigerantLeakDetector
OBJECT-TYPE
This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only. The read returns -1. Only 'yes' is supported.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.12INTEGER {no(1), yes(2)}read-writemandatory
airIRG3RDUConfigOnReadyStandby
OBJECT-TYPE
This parameter allows to configure RDU on/standby parameter. Ready is currently not supported. If unsupported returns -1.
1.3.6.1.4.1.318.1.1.13.6.4.7.1.13INTEGER {standby(1), ready(2), on(3)}read-writemandatory
airIRG3CM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.13.6.5
airIRG3CMTableSize
OBJECT-TYPE
The cooling module table size.
1.3.6.1.4.1.318.1.1.13.6.5.1INTEGERread-onlymandatory
airIRG3CMStatusTable
OBJECT-TYPE
Allows to access CM status table.
1.3.6.1.4.1.318.1.1.13.6.5.2not-accessiblemandatory
airIRG3CMStatusEntry
OBJECT-TYPE
The CM status table entry.
1.3.6.1.4.1.318.1.1.13.6.5.2.1not-accessiblemandatory
airIRG3CMStatusDeviceIndex
OBJECT-TYPE
Index of CM status table.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.1INTEGERread-onlymandatory
airIRG3CMStatusCMID
OBJECT-TYPE
The CM ID (RDU Number - Group Number - CM Unit Number).
1.3.6.1.4.1.318.1.1.13.6.5.2.1.2DisplayStringread-onlymandatory
airIRG3CMStatusOperatingMode
OBJECT-TYPE
The current operating mode of the CM.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.3INTEGER {standBy(1), on(2), idle(3)}read-onlymandatory
airIRG3CMStatusUnitType
OBJECT-TYPE
The current CM unit type.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.4INTEGER {unconfigured(1), oa(2), ra(3)}read-onlymandatory
airIRG3CMStatusRackInletTempUS
OBJECT-TYPE
The CM rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.5INTEGERread-onlymandatory
airIRG3CMStatusRackInletTempMetric
OBJECT-TYPE
The CM rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.6INTEGERread-onlymandatory
airIRG3CMStatusReturnAirTempUS
OBJECT-TYPE
The CM return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.7INTEGERread-onlymandatory
airIRG3CMStatusReturnAirTempMetric
OBJECT-TYPE
The CM return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.8INTEGERread-onlymandatory
airIRG3CMStatusLiquidTempUS
OBJECT-TYPE
The CM liquid temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.9INTEGERread-onlymandatory
airIRG3CMStatusLiquidTempMetric
OBJECT-TYPE
The CM liquid temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.10INTEGERread-onlymandatory
airIRG3CMStatusVaporTempUS
OBJECT-TYPE
The CM vapor temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.11INTEGERread-onlymandatory
airIRG3CMStatusVaporTempMetric
OBJECT-TYPE
The CM vapor temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.12INTEGERread-onlymandatory
airIRG3CMStatusEvaporatorTempUS
OBJECT-TYPE
The CM saturation temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.13INTEGERread-onlymandatory
airIRG3CMStatusEvaporatorTempMetric
OBJECT-TYPE
The CM saturation temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.14INTEGERread-onlymandatory
airIRG3CMStatusLiquidInletPressureUS
OBJECT-TYPE
The CM Liquid Inlet pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.6.5.2.1.15INTEGERread-onlymandatory
airIRG3CMStatusLiquidInletPressureMetric
OBJECT-TYPE
The CM Liquid Inlet pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.6.5.2.1.16INTEGERread-onlymandatory
airIRG3CMStatusVaporOutletPressureUS
OBJECT-TYPE
The CM Vapor Outlet pressure in pounds per square inch (PSI).
1.3.6.1.4.1.318.1.1.13.6.5.2.1.17INTEGERread-onlymandatory
airIRG3CMStatusVaporOutletPressureMetric
OBJECT-TYPE
The CM Vapor Outlet pressure in kiloPascals (kPa).
1.3.6.1.4.1.318.1.1.13.6.5.2.1.18INTEGERread-onlymandatory
airIRG3CMStatusExpansionValvePosition
OBJECT-TYPE
The CM expansion valve position in % open
1.3.6.1.4.1.318.1.1.13.6.5.2.1.19INTEGERread-onlymandatory
airIRG3CMStatusEPRValvePosition
OBJECT-TYPE
The CM Evaporator Pressure Regulator Valve Position in tenths of percent open
1.3.6.1.4.1.318.1.1.13.6.5.2.1.20INTEGERread-onlymandatory
airIRG3CMStatusLocalDisplayOnOffEnabled
OBJECT-TYPE
The status of the on/off control on the CM local display.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.21INTEGER {no(1), yes(2)}read-onlymandatory
airIRG3CMStatusAverageFanSpeed
OBJECT-TYPE
The CM Average Fan Speed.
1.3.6.1.4.1.318.1.1.13.6.5.2.1.22INTEGERread-onlymandatory
airIRG3CMRunHoursTable
OBJECT-TYPE
Allows to access CM run hours table.
1.3.6.1.4.1.318.1.1.13.6.5.3not-accessiblemandatory
airIRG3CMRunHoursEntry
OBJECT-TYPE
The CM run hours table entry.
1.3.6.1.4.1.318.1.1.13.6.5.3.1not-accessiblemandatory
airIRG3CMRunHoursDeviceIndex
OBJECT-TYPE
Index of CM run hours table.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.1INTEGERread-onlymandatory
airIRG3CMRunHoursCMID
OBJECT-TYPE
The CM ID (RDU Number - Group Number - CM Unit Number).
1.3.6.1.4.1.318.1.1.13.6.5.3.1.2DisplayStringread-onlymandatory
airIRG3CMRunHoursFan1
OBJECT-TYPE
The CM run hours for Fan1. Returns (-1) if not appilcable.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.3INTEGERread-onlymandatory
airIRG3CMRunHoursFan2
OBJECT-TYPE
The CM run hours for Fan2. Returns (-1) if not appilcable.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.4INTEGERread-onlymandatory
airIRG3CMRunHoursFan3
OBJECT-TYPE
The CM run hours for Fan3. Returns (-1) if not appilcable.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.5INTEGERread-onlymandatory
airIRG3CMRunHoursFan4
OBJECT-TYPE
The CM run hours for Fan4. Returns (-1) if not appilcable.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.6INTEGERread-onlymandatory
airIRG3CMRunHoursFan5
OBJECT-TYPE
The CM run hours for Fan5. Returns (-1) if not appilcable.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.7INTEGERread-onlymandatory
airIRG3CMRunHoursAirFilter
OBJECT-TYPE
The CM run hours for air filter.
1.3.6.1.4.1.318.1.1.13.6.5.3.1.8INTEGERread-onlymandatory
airIRG3CMServiceIntervalsTable
OBJECT-TYPE
Allows to access CM service intervals table.
1.3.6.1.4.1.318.1.1.13.6.5.4not-accessiblemandatory
airIRG3CMServiceIntervalsEntry
OBJECT-TYPE
The CM service interval table entry.
1.3.6.1.4.1.318.1.1.13.6.5.4.1not-accessiblemandatory
airIRG3CMServiceIntervalsDeviceIndex
OBJECT-TYPE
Index of CM service intervals table.
1.3.6.1.4.1.318.1.1.13.6.5.4.1.1INTEGERread-onlymandatory
airIRG3CMServiceIntervalsCMID
OBJECT-TYPE
The CM ID (RDU Number - Group Number - CM Unit Number).
1.3.6.1.4.1.318.1.1.13.6.5.4.1.2DisplayStringread-onlymandatory
airIRG3CMServiceIntervalsAirFilterInterval
OBJECT-TYPE
The CM service interval for air filter in weeks. Supported only for RA. Returns -1 if not supported.
1.3.6.1.4.1.318.1.1.13.6.5.4.1.3INTEGERread-writemandatory
airIRG3CMServiceIntervalsAirFilterAlarm
OBJECT-TYPE
The CM service interval air filter alarm status. Supported only for RA. Returns -1 if not supported.
1.3.6.1.4.1.318.1.1.13.6.5.4.1.4INTEGER {disable(1), enable(2)}read-writemandatory
airIRG3CMThresholdsTable
OBJECT-TYPE
Allows to access CM thresholds table.
1.3.6.1.4.1.318.1.1.13.6.5.5not-accessiblemandatory
airIRG3CMThresholdsEntry
OBJECT-TYPE
The CM thresholds table entry.
1.3.6.1.4.1.318.1.1.13.6.5.5.1not-accessiblemandatory
airIRG3CMThresholdsDeviceIndex
OBJECT-TYPE
Index for CM thresholds table.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.1INTEGERread-onlymandatory
airIRG3CMThresholdsCMID
OBJECT-TYPE
The CM ID (RDU Number - Group Number - CM Unit Number).
1.3.6.1.4.1.318.1.1.13.6.5.5.1.2DisplayStringread-onlymandatory
airIRG3CMThresholdsRackInletTempHighUS
OBJECT-TYPE
The CM high threshold for rack inlet temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.3INTEGERread-writemandatory
airIRG3CMThresholdsRackInletTempHighMetric
OBJECT-TYPE
The CM high threshold for rack inlet temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.4INTEGERread-writemandatory
airIRG3CMThresholdsSupplyAirTempHighUS
OBJECT-TYPE
The CM high threshold for supply air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.5INTEGERread-writemandatory
airIRG3CMThresholdsSupplyAirTempHighMetric
OBJECT-TYPE
The CM high threshold for supply air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.6INTEGERread-writemandatory
airIRG3CMThresholdsReturnAirTempHighUS
OBJECT-TYPE
The CM high threshold for return air temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.7INTEGERread-writemandatory
airIRG3CMThresholdsReturnAirTempHighMetric
OBJECT-TYPE
The CM high threshold for return air temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.13.6.5.5.1.8INTEGERread-writemandatory
airIRG3CMSetpointsTable
OBJECT-TYPE
Allows to access CM set points table.
1.3.6.1.4.1.318.1.1.13.6.5.6not-accessiblemandatory
airIRG3CMSetpointsEntry
OBJECT-TYPE
The CM set points table entry.
1.3.6.1.4.1.318.1.1.13.6.5.6.1not-accessiblemandatory
airIRG3CMSetpointsDeviceIndex
OBJECT-TYPE
Index of CM set points table.
1.3.6.1.4.1.318.1.1.13.6.5.6.1.1INTEGERread-onlymandatory
airIRG3CMConfigTable
OBJECT-TYPE
Allows to access CM configuration table.
1.3.6.1.4.1.318.1.1.13.6.5.7not-accessiblemandatory
airIRG3CMConfigEntry
OBJECT-TYPE
The CM configuration table entry.
1.3.6.1.4.1.318.1.1.13.6.5.7.1not-accessiblemandatory
airIRG3CMConfigDeviceIndex
OBJECT-TYPE
Index of CM configuration table.
1.3.6.1.4.1.318.1.1.13.6.5.7.1.1INTEGERread-onlymandatory
airIRG3CMConfigCMID
OBJECT-TYPE
The CM ID (RDU Number - Group Number - CM Unit Number).
1.3.6.1.4.1.318.1.1.13.6.5.7.1.2DisplayStringread-onlymandatory
airIRG3CMConfigStopOnCoolFail
OBJECT-TYPE
Enable/Disable Stop On cool fail. When enabled, stops the unit if it detects that it is blowing warm air into the cold aisle.
1.3.6.1.4.1.318.1.1.13.6.5.7.1.3INTEGER {no(1), yes(2)}read-writemandatory
airIRG3CMConfigStartupDelay
OBJECT-TYPE
The CM start up delay in seconds.
1.3.6.1.4.1.318.1.1.13.6.5.7.1.4INTEGERread-writemandatory
airIRG3CMConfigRemoteOnStandby
OBJECT-TYPE
The CM configuration for operating mode.
1.3.6.1.4.1.318.1.1.13.6.5.7.1.5INTEGER {standBy(1), on(2)}read-writemandatory
airIRG3CMConfigPowerSource
OBJECT-TYPE
The CM power source.
1.3.6.1.4.1.318.1.1.13.6.5.7.1.6INTEGER {singleFeed(1), dualFeed(2)}read-writemandatory
rARU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14
rARUIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14.1
rARUIdentTable
OBJECT-TYPE
Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID.
1.3.6.1.4.1.318.1.1.14.1.1not-accessiblemandatory
rARUIdentEntry
OBJECT-TYPE
The device to query.
1.3.6.1.4.1.318.1.1.14.1.1.1not-accessiblemandatory
rARUIdentAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.1.1.1.1INTEGERread-onlymandatory
rARUIdentName
OBJECT-TYPE
A character string identifying the device.
1.3.6.1.4.1.318.1.1.14.1.1.1.2DisplayStringread-onlymandatory
rARUConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14.2
rARUConfigTable
OBJECT-TYPE
Allows for configuration of the individual ARU devices accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
1.3.6.1.4.1.318.1.1.14.2.1not-accessiblemandatory
rARUConfigEntry
OBJECT-TYPE
The ARUs to configure.
1.3.6.1.4.1.318.1.1.14.2.1.1not-accessiblemandatory
rARUConfigAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.2.1.1.1INTEGERread-onlymandatory
rARUConfigAruName
OBJECT-TYPE
The name of the ARU.
1.3.6.1.4.1.318.1.1.14.2.1.1.2DisplayStringread-writemandatory
rARUConfigAruRemoteSetpoint
OBJECT-TYPE
This OID defines the desired base airflow of the ARU, and sets the speed of the ARU fans when the temperature override is inactive. Values specified in cfm (cubic feet per minute) can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour). Values (1) through (9) are for support of legacy (1st generation) ARUs. Writing these values to a 2nd generation ARU will result in the following: A value greater than (9) will be ignored by a 1st generation ARU. aruOff (1) - Ignored aru85F-29C (2) - 1200 cfm aru90F-32C (3) - 800 cfm aru95F-35C (4) - 500 cfm aru100F-38C (5) - 400 cfm aru7kW (6) - 1200 cfm aru5kW (7) - 800 cfm aru3kW (8) - 500 cfm aru2kW (9) - 400 cfm NOTE: -1 will be returned if the ARU is not communicating.
1.3.6.1.4.1.318.1.1.14.2.1.1.3INTEGER {aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW-1200cfm(6), aru5kW-800cfm(7), aru3kW-500cfm(8), aru2kW-300cfm(9), aru400cfm(10), aru600cfm(11), aru700cfm(12), aru900cfm(13), aru1000cfm(14), aru1400cfm(15), aru1600cfm(16), aru1800cfm(17), aru2000cfm(18)}read-writemandatory
rARUConfigAruTempOvrdEnableDisable
OBJECT-TYPE
This OID is used to enable/disable the remote temperature override setting of the ARU. If this OID is set to 1, the remote setting for temperature override is disabled. If this OID is set to 2, the remote setting for temperature override is enabled.
1.3.6.1.4.1.318.1.1.14.2.1.1.4INTEGER {disabled(1), enabled(2)}read-writemandatory
rARUConfigAruTempOvrdSetpoint
OBJECT-TYPE
This OID is the Temperature Override setpoint of the ARU. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees using the units specified in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.14.2.1.1.5INTEGERread-writemandatory
rARUConfigAruMasterControl
OBJECT-TYPE
This is the master on/off control for the ARU.
1.3.6.1.4.1.318.1.1.14.2.1.1.6INTEGER {aruOn(1), aruOff(2)}read-writemandatory
rARUStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14.3
rARUStatusAruDeviceCount
OBJECT-TYPE
The total number of ARUs accessible from this IP.
1.3.6.1.4.1.318.1.1.14.3.1INTEGERread-onlymandatory
rARUStatusSysTempUnits
OBJECT-TYPE
The temperature scale used to display the temperature in the system, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
1.3.6.1.4.1.318.1.1.14.3.2INTEGER {celsius(1), fahrenheit(2)}read-onlymandatory
rARUStatusTable
OBJECT-TYPE
Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
1.3.6.1.4.1.318.1.1.14.3.3not-accessiblemandatory
rARUStatusEntry
OBJECT-TYPE
The ARUs to access.
1.3.6.1.4.1.318.1.1.14.3.3.1not-accessiblemandatory
rARUStatusAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.3.3.1.1INTEGERread-onlymandatory
rARUStatusAruName
OBJECT-TYPE
The name of the ARU.
1.3.6.1.4.1.318.1.1.14.3.3.1.2DisplayStringread-onlymandatory
rARUStatusAruRemoteSetpoint
OBJECT-TYPE
This OID defines the desired base airflow of the ARU, or the speed of the ARU fans when the temperature override is inactive. See also the rARUConfigAruRemoteSetpoint OID. NOTE: -1 will be returned if the ARU is not communicating.
1.3.6.1.4.1.318.1.1.14.3.3.1.3INTEGER {aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW-1200cfm(6), aru5kW-800cfm(7), aru3kW-500cfm(8), aru2kW-300cfm(9), aru400cfm(10), aru600cfm(11), aru700cfm(12), aru900cfm(13), aru1000cfm(14), aru1400cfm(15), aru1600cfm(16), aru1800cfm(17), aru2000cfm(18)}read-onlymandatory
rARUStatusAruManualSetpoint
OBJECT-TYPE
Manual operating setpoint of the ARU, which is set on the panel of the ARU. If the ARU doesn't have a manual , the OID will always return a value of aruRem (10). NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees or kW. If the manual setpoint is set to Remote, or if the ARU doesn't have a manual switch, this OID will return aruRem.
1.3.6.1.4.1.318.1.1.14.3.3.1.4INTEGER {aruOff(1), aru85F-29C(2), aru90F-32C(3), aru95F-35C(4), aru100F-38C(5), aru7kW(6), aru5kW(7), aru3kW(8), aru2kW(9), aruRem(10)}read-onlymandatory
rARUStatusAruTemp1
OBJECT-TYPE
ARU temperature probe #1 reading. The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.14.3.3.1.5INTEGERread-onlymandatory
rARUStatusAruTemp2
OBJECT-TYPE
ARU temperature probe #2 reading. The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.14.3.3.1.6INTEGERread-onlymandatory
rARUStatusAruTemp3
OBJECT-TYPE
ARU temperature probe #3 reading. The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.14.3.3.1.7INTEGERread-onlymandatory
rARUStatusAruTempOvrdEnableDisable
OBJECT-TYPE
This OID indicates whether the ARU remote temperature override is enabled or disabled. If this OID is a 1, the remote setting for temperature override is disabled. If this OID is a 2, the remote setting for temperature override is enabled.
1.3.6.1.4.1.318.1.1.14.3.3.1.8INTEGER {disabled(1), enabled(2)}read-onlymandatory
rARUStatusAruTempOvrdSetpoint
OBJECT-TYPE
ARU remote temperature override setpoint setting. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale shown in the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
1.3.6.1.4.1.318.1.1.14.3.3.1.9INTEGERread-onlymandatory
rARUStatusAruAlarmState
OBJECT-TYPE
An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 8, read from left to right. The flags are defined as follows: Flag 1: Fan Fail 1 Flag 2: Fan Fail 2 Flag 3: Fan Fail 3 Flag 4: Smoke (if ARU is equipped with smoke detector) Flag 5: High Temp (Out of Thermal Control) Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint) Flag 7: Fan Fail 4 (Gen 2 ARU only) Flag 8: Reserved
1.3.6.1.4.1.318.1.1.14.3.3.1.10DisplayStringread-onlymandatory
rARUStatusAruCommStatus
OBJECT-TYPE
The state of communications to the device. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no device.
1.3.6.1.4.1.318.1.1.14.3.3.1.11INTEGER {commsNeverDiscovered(1), commsEstablished(2), commsLost(3)}read-onlymandatory
rARUStatusAruTempOvrdStatus
OBJECT-TYPE
Specifies whether the ARU is increasing airflow because exhaust air temperature has exceeded the setting specified in the rARUConfigAruTempOvrdSetpoint OID.
1.3.6.1.4.1.318.1.1.14.3.3.1.12INTEGER {inactive(1), active(2)}read-onlymandatory
rARUStatusAruMasterControl
OBJECT-TYPE
This is the master on/off control for the ARU.
1.3.6.1.4.1.318.1.1.14.3.3.1.13INTEGER {aruOn(1), aruOff(2)}read-onlymandatory
rARUStatusAruTotalAirflow
OBJECT-TYPE
The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour).
1.3.6.1.4.1.318.1.1.14.3.3.1.14INTEGERread-onlymandatory
rARUFanStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14.4
rARUFanStatusTable
OBJECT-TYPE
Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID.
1.3.6.1.4.1.318.1.1.14.4.1not-accessiblemandatory
rARUFanStatusEntry
OBJECT-TYPE
The device to query.
1.3.6.1.4.1.318.1.1.14.4.1.1not-accessiblemandatory
rARUFanStatusAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.4.1.1.1INTEGERread-onlymandatory
rARUFanStatusNominalFanSpeed
OBJECT-TYPE
The nominal rotational speed (RPM) of the fans when they are operating at the 100% level.
1.3.6.1.4.1.318.1.1.14.4.1.1.2INTEGERread-onlymandatory
rARUFanStatusSelectedFanLevel
OBJECT-TYPE
The currently selected ARU speed level, specified in percent of full capacity.
1.3.6.1.4.1.318.1.1.14.4.1.1.3INTEGERread-onlymandatory
rARUFanStatusReplacementThreshold
OBJECT-TYPE
Threshold above which a run hour alarm will exist, indicating that it might be time to proactively replace a fan.
1.3.6.1.4.1.318.1.1.14.4.1.1.4INTEGER {disabled(1), khr20(2), khr25(3), khr30(4), khr35(5), khr40(6), khr50(7)}read-writemandatory
rARUFanStatusFanIndex
OBJECT-TYPE
The index to an individual fan table entry.
1.3.6.1.4.1.318.1.1.14.4.1.1.5INTEGERread-onlymandatory
rARUFanStatusFanOperatingStatus
OBJECT-TYPE
The current operating state of the fan.
1.3.6.1.4.1.318.1.1.14.4.1.1.6INTEGER {unknown(1), off(2), onOk(3), onDegraded(4), offFailed(5)}read-onlymandatory
rARUFanStatusFanRpmSpeed
OBJECT-TYPE
The current rotational speed of the fan, specified in rotations per minute (RPM).
1.3.6.1.4.1.318.1.1.14.4.1.1.7INTEGERread-onlymandatory
rARUFanStatusFanFlowRate
OBJECT-TYPE
The flow rate provided by the fan, based on its measured rotational speed. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour).
1.3.6.1.4.1.318.1.1.14.4.1.1.8INTEGERread-onlymandatory
rARUFanStatusFanInServiceDate
OBJECT-TYPE
The installation/replacement date of the fan.
1.3.6.1.4.1.318.1.1.14.4.1.1.9DisplayStringread-writemandatory
rARUFanStatusFanRunhourCounter
OBJECT-TYPE
The total time for which the fan has been running. Specified in 10ths of hours.
1.3.6.1.4.1.318.1.1.14.4.1.1.10INTEGERread-onlymandatory
rARUFanStatusFanRunhourReset
OBJECT-TYPE
Writing yes to this This OID will reset a fan's total run hour counter, which is shown in the rARUFanStatusFanRunhourCounter OID.
1.3.6.1.4.1.318.1.1.14.4.1.1.11INTEGER {yes(1), no(2)}read-writemandatory
rARUPower
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14.5
rARUPowerStatusTable
OBJECT-TYPE
Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
1.3.6.1.4.1.318.1.1.14.5.1not-accessiblemandatory
rARUPowerStatusEntry
OBJECT-TYPE
The device to query.
1.3.6.1.4.1.318.1.1.14.5.1.1not-accessiblemandatory
rARUPowerStatusAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.5.1.1.1INTEGERread-onlymandatory
rARUPowerStatusPrimaryAcPresent
OBJECT-TYPE
Indicates whether or not line voltage is present on AC input 1.
1.3.6.1.4.1.318.1.1.14.5.1.1.2INTEGER {yes(1), no(2)}read-onlymandatory
rARUPowerStatusAuxiliaryAcPresent
OBJECT-TYPE
Indicates whether or not line voltage is present on AC input 2.
1.3.6.1.4.1.318.1.1.14.5.1.1.3INTEGER {yes(1), no(2)}read-onlymandatory
rARUPowerStatusRedundantAcConfig
OBJECT-TYPE
Indicates whether or not a dual cord is in use. When this setting is set to dualCord (2), aruRedundantPowerLostAlarm traps will be generated when either primary or auxiliary input voltage is not present. When this setting is set to singleCord (1), aruRedundantPowerLostAlarm traps will not be generated.
1.3.6.1.4.1.318.1.1.14.5.1.1.4INTEGER {singleCord(1), dualCord(2)}read-writemandatory
rARUSensors
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.14.6
rARUSensorsStatusTableSize
OBJECT-TYPE
The number of entries in the rARUSensorsStatusTable.
1.3.6.1.4.1.318.1.1.14.6.1INTEGERread-onlymandatory
rARUSensorsStatusTable
OBJECT-TYPE
Allows for getting environmental sensor status information.
1.3.6.1.4.1.318.1.1.14.6.2not-accessiblemandatory
rARUSensorsStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.14.6.2.1not-accessiblemandatory
rARUSensorsStatusAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.6.2.1.1INTEGERread-onlymandatory
rARUSensorsStatusSensorNumber
OBJECT-TYPE
The number of the sensor on the device.
1.3.6.1.4.1.318.1.1.14.6.2.1.2INTEGERread-onlymandatory
rARUSensorsTemperature
OBJECT-TYPE
The sensor's current temperature reading. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.2.1.3INTEGERread-onlymandatory
rARUSensorsConfigTableSize
OBJECT-TYPE
The number of entries in the rARUSensorsConfigTable.
1.3.6.1.4.1.318.1.1.14.6.3INTEGERread-onlymandatory
rARUSensorsConfigTable
OBJECT-TYPE
Allows for getting configuration information from environmental sensors attached to the device.
1.3.6.1.4.1.318.1.1.14.6.4not-accessiblemandatory
rARUSensorsConfigEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.14.6.4.1not-accessiblemandatory
rARUSensorsConfigAruIndex
OBJECT-TYPE
The index to the ARU entry.
1.3.6.1.4.1.318.1.1.14.6.4.1.1INTEGERread-onlymandatory
rARUSensorsConfigSensorNumber
OBJECT-TYPE
The number of the sensor on the device.
1.3.6.1.4.1.318.1.1.14.6.4.1.2INTEGERread-onlymandatory
rARUSensorsName
OBJECT-TYPE
A descriptive name for the sensor.
1.3.6.1.4.1.318.1.1.14.6.4.1.3DisplayStringread-writemandatory
rARUSensorsLocation
OBJECT-TYPE
The location of the sensor.
1.3.6.1.4.1.318.1.1.14.6.4.1.4DisplayStringread-writemandatory
rARUSensorsTempMaxThresh
OBJECT-TYPE
The temperature at which a maximum temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.5INTEGERread-writemandatory
rARUSensorsTempHighThresh
OBJECT-TYPE
The temperature at which a high temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.6INTEGERread-writemandatory
rARUSensorsTempLowThresh
OBJECT-TYPE
The temperature at which a low temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.7INTEGERread-writemandatory
rARUSensorsTempMinThresh
OBJECT-TYPE
The temperature at which a min temperature threshold violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.8INTEGERread-writemandatory
rARUSensorsTempThreshHysteresis
OBJECT-TYPE
The change in temperature required to cause a temperature alarm to change from an active to an inactive state. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.9INTEGERread-writemandatory
rARUSensorsTempShortDecRateThreshValue
OBJECT-TYPE
The value of the temperature short-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.10INTEGERread-writemandatory
rARUSensorsTempShortDecRateThreshTime
OBJECT-TYPE
The time over which the temperature may not decrease beyond the value specified by the temperature short-term decreasing rate threshold value.
1.3.6.1.4.1.318.1.1.14.6.4.1.11INTEGERread-writemandatory
rARUSensorsTempShortIncRateThreshValue
OBJECT-TYPE
The value of the temperature short-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.12INTEGERread-writemandatory
rARUSensorsTempShortIncRateThreshTime
OBJECT-TYPE
The time over which the temperature may not increase beyond the value specified by the temperature short-term increasing rate threshold value.
1.3.6.1.4.1.318.1.1.14.6.4.1.13INTEGERread-writemandatory
rARUSensorsTempLongDecRateThreshValue
OBJECT-TYPE
The value of the temperature long-term decreasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.14INTEGERread-writemandatory
rARUSensorsTempLongDecRateThreshTime
OBJECT-TYPE
The time over which the temperature may not decrease beyond the value specified by the temperature long-term decreasing rate threshold value.
1.3.6.1.4.1.318.1.1.14.6.4.1.15INTEGERread-writemandatory
rARUSensorsTempLongIncRateThreshValue
OBJECT-TYPE
The value of the temperature long-term increasing rate time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration.
1.3.6.1.4.1.318.1.1.14.6.4.1.16INTEGERread-writemandatory
rARUSensorsTempLongIncRateThreshTime
OBJECT-TYPE
The time over which the temperature may not increase beyond the value specified by the temperature long-term increasing rate threshold value.
1.3.6.1.4.1.318.1.1.14.6.4.1.17INTEGERread-writemandatory
xPDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15
xPDUIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.1
xPDUIdentProductName
OBJECT-TYPE
The name of the PDU.
1.3.6.1.4.1.318.1.1.15.1.1DisplayStringread-writemandatory
xPDUIdentHardwareRev
OBJECT-TYPE
The hardware revision of the PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.15.1.2DisplayStringread-onlymandatory
xPDUIdentFirmwareAppRev
OBJECT-TYPE
An ID string identifying the application firmware revision of the PDU.
1.3.6.1.4.1.318.1.1.15.1.3DisplayStringread-onlymandatory
xPDUIdentFirmwareAppOSRev
OBJECT-TYPE
An ID string identifying the application operating system firmware revision of the PDU.
1.3.6.1.4.1.318.1.1.15.1.4DisplayStringread-onlymandatory
xPDUIdentFirmwareControllerRev
OBJECT-TYPE
An ID string identifying the PDU controller firmware revision.
1.3.6.1.4.1.318.1.1.15.1.5DisplayStringread-onlymandatory
xPDUIdentDateOfManufacture
OBJECT-TYPE
The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.15.1.6DisplayStringread-onlymandatory
xPDUIdentModelNumber
OBJECT-TYPE
A character string identifying the model number of the PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.15.1.7DisplayStringread-onlymandatory
xPDUIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.15.1.8DisplayStringread-onlymandatory
xPDUDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.2
xPDUDeviceNominalMainInputVoltage
OBJECT-TYPE
The nominal main input voltage to the PDU. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service.
1.3.6.1.4.1.318.1.1.15.2.1INTEGERread-onlymandatory
xPDUDeviceServiceType
OBJECT-TYPE
The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye).
1.3.6.1.4.1.318.1.1.15.2.2INTEGER {threeWire(1), fourWire(2)}read-onlymandatory
xPDUDeviceNominalOutputVoltage
OBJECT-TYPE
The nominal line-to-neutral output voltage to the load measured in Volts.
1.3.6.1.4.1.318.1.1.15.2.3INTEGERread-onlymandatory
xPDUDeviceMainInputBreakerRating
OBJECT-TYPE
The rating of the main input breaker measured in Amps.
1.3.6.1.4.1.318.1.1.15.2.4INTEGERread-onlymandatory
xPDUDevicePanelBreakerRating
OBJECT-TYPE
The rating of the panel breaker measured in Amps.
1.3.6.1.4.1.318.1.1.15.2.5INTEGERread-onlymandatory
xPDUDeviceTransformerPresent
OBJECT-TYPE
Indicates whether or not a transformer is installed in the PDU.
1.3.6.1.4.1.318.1.1.15.2.6INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceLoadTieBreakerPresent
OBJECT-TYPE
Indicates whether or not a load tie breaker is installed in the PDU.
1.3.6.1.4.1.318.1.1.15.2.7INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceLoadTestPortPresent
OBJECT-TYPE
Indicates whether or not a load test port is installed in the PDU.
1.3.6.1.4.1.318.1.1.15.2.8INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceFusesPresent
OBJECT-TYPE
Indicates whether or not the UPS feed from the PDU includes fuses.
1.3.6.1.4.1.318.1.1.15.2.9INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceFansPresent
OBJECT-TYPE
Indicates whether or not cooling fans are installed in the PDU.
1.3.6.1.4.1.318.1.1.15.2.10INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceBypassInputPresent
OBJECT-TYPE
Indicates whether or not the PDU is equipped with a second feed for the UPS's bypass input.
1.3.6.1.4.1.318.1.1.15.2.11INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceCrossTieOutputPresent
OBJECT-TYPE
Indicates whether or not the PDU is equipped with a cross-tie output.
1.3.6.1.4.1.318.1.1.15.2.12INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceEarthGroundMonitorPresent
OBJECT-TYPE
Indicates whether or not the PDU can provide ground current measurements.
1.3.6.1.4.1.318.1.1.15.2.13INTEGER {notPresent(1), present(2)}read-onlymandatory
xPDUDeviceInfraStruXureType
OBJECT-TYPE
Indicates the configuration of this PDU system. Type-B PDU is in a distributed UPS system and has bypass capabilities. Type-C PDU receives power from a larger central UPS.
1.3.6.1.4.1.318.1.1.15.2.14INTEGER {typeB(1), typeC(2)}read-onlymandatory
xPDUACMonitoringPoint
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.3
xPDUMainInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.3.1
xPDUMainInputOverVoltThreshold
OBJECT-TYPE
Threshold above which an input over voltage condition will be generated. Specified as percent deviation from nominal.
1.3.6.1.4.1.318.1.1.15.3.1.1INTEGER (0..30)read-writemandatory
xPDUMainInputUnderVoltThreshold
OBJECT-TYPE
Threshold below which an input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.15.3.1.2INTEGER (0..30)read-writemandatory
xPDUMainInputVoltageTableSize
OBJECT-TYPE
The number of Main input voltage entries.
1.3.6.1.4.1.318.1.1.15.3.1.3INTEGERread-onlymandatory
xPDUMainInputVoltagePhaseTable
OBJECT-TYPE
A list of input voltage table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUMainInputVoltageTableSize OID.
1.3.6.1.4.1.318.1.1.15.3.1.4not-accessiblemandatory
xPDUMainInputVoltagePhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular main input voltage phase.
1.3.6.1.4.1.318.1.1.15.3.1.4.1not-accessiblemandatory
xPDUMainInputVoltagePhaseIndex
OBJECT-TYPE
Description of each input phase entry in the table.
1.3.6.1.4.1.318.1.1.15.3.1.4.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xPDUMainInputVoltageLtoL
OBJECT-TYPE
Line-to-line PDU input voltage when an isolation transformer is present, or -1 if no transformer present in this PDU. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.15.3.1.4.1.2INTEGERread-onlymandatory
xPDUMainInputVoltageLtoN
OBJECT-TYPE
Line-to-neutral PDU input voltage when an isolation transformer is not present, or -1 if a transformer is present in this PDU. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.15.3.1.4.1.3INTEGERread-onlymandatory
xPDUBypassInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.3.2
xPDUBypassInputOverVoltThreshold
OBJECT-TYPE
Threshold above which a bypass input over voltage condition will be generated. Specified as percent deviation from nominal.
1.3.6.1.4.1.318.1.1.15.3.2.1INTEGER (0..30)read-writemandatory
xPDUBypassInputUnderVoltThreshold
OBJECT-TYPE
Threshold below which an bypass input under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.15.3.2.2INTEGER (0..30)read-writemandatory
xPDUBypassInputVoltagePhaseTableSize
OBJECT-TYPE
The number of bypass input voltage entries.
1.3.6.1.4.1.318.1.1.15.3.2.3INTEGERread-onlymandatory
xPDUBypassInputVoltagePhaseTable
OBJECT-TYPE
A list of output table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUBypassInputVoltagePhaseTableSize OID.
1.3.6.1.4.1.318.1.1.15.3.2.4not-accessiblemandatory
xPDUBypassInputVoltagePhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular bypass input voltage phase.
1.3.6.1.4.1.318.1.1.15.3.2.4.1not-accessiblemandatory
xPDUBypassInputVoltagePhaseIndex
OBJECT-TYPE
Index of each bypass input phase entry in the table.
1.3.6.1.4.1.318.1.1.15.3.2.4.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xPDUBypassInputVoltageLtoL
OBJECT-TYPE
Line-to-line bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.15.3.2.4.1.2INTEGERread-onlymandatory
xPDUBypassInputVoltageLtoN
OBJECT-TYPE
Line-to-neutral bypass input voltage, or -1 if no bypass feed is present in this PDU. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.15.3.2.4.1.3INTEGERread-onlymandatory
xPDUUPSInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.3.3
xPDUUPSInputVoltagePhaseTableSize
OBJECT-TYPE
The number of UPS input voltage entries.
1.3.6.1.4.1.318.1.1.15.3.3.1INTEGERread-onlymandatory
xPDUUPSInputVoltagePhaseTable
OBJECT-TYPE
A list of UPS input table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUUPSInputVoltagePhaseTableSize OID.
1.3.6.1.4.1.318.1.1.15.3.3.2not-accessiblemandatory
xPDUUPSInputVoltagePhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular UPS input voltage phase.
1.3.6.1.4.1.318.1.1.15.3.3.2.1not-accessiblemandatory
xPDUUPSInputVoltagePhaseIndex
OBJECT-TYPE
Description of each UPS input phase entry in the table.
1.3.6.1.4.1.318.1.1.15.3.3.2.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xPDUUPSInputVoltageLtoNPresent
OBJECT-TYPE
Indicates whether or not voltage is present at the UPS feed.
1.3.6.1.4.1.318.1.1.15.3.3.2.1.2INTEGER {notPresent(1), present(2), unknown(3)}read-onlymandatory
xPDUSystemOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.3.4
xPDUSystemOutputFrequency
OBJECT-TYPE
The system output frequency in tenths of Hertz.
1.3.6.1.4.1.318.1.1.15.3.4.1INTEGERread-onlymandatory
xPDUSystemOutputNeutralCurrent
OBJECT-TYPE
Shows the neutral current measured at the system output in tenths of Amps.
1.3.6.1.4.1.318.1.1.15.3.4.2INTEGERread-onlymandatory
xPDUSystemOutputTotalPower
OBJECT-TYPE
Shows the total system output power in tenths of kW.
1.3.6.1.4.1.318.1.1.15.3.4.3INTEGERread-onlymandatory
xPDUSystemOutputTotalApparentPower
OBJECT-TYPE
Shows the total system output power in tenths of kVA.
1.3.6.1.4.1.318.1.1.15.3.4.4INTEGERread-onlymandatory
xPDUSystemOutputTotalPowerFactor
OBJECT-TYPE
Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00). Measured in hundredths.
1.3.6.1.4.1.318.1.1.15.3.4.5INTEGERread-onlymandatory
xPDUSystemOutputFrequencyTolerance
OBJECT-TYPE
Shows the circuit panel output frequency tolerance in Hertz.
1.3.6.1.4.1.318.1.1.15.3.4.6INTEGER {freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10)}read-writemandatory
xPDUSystemOutputMaxKWPower
OBJECT-TYPE
Defines 100% load in kW. Purpose is to set to match UPS capabilities.
1.3.6.1.4.1.318.1.1.15.3.4.7INTEGERread-writemandatory
xPDUSystemOutputOverVoltThreshold
OBJECT-TYPE
Threshold above which an output over voltage condition will be generated. Specified as percent deviation from nominal.
1.3.6.1.4.1.318.1.1.15.3.4.8INTEGER (0..30)read-writemandatory
xPDUSystemOutputUnderVoltThreshold
OBJECT-TYPE
Threshold below which an output under voltage condition will be generated. Specified as percent deviation from nominal. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.15.3.4.9INTEGER (0..30)read-writemandatory
xPDUSystemOutputOverCurrentThreshold
OBJECT-TYPE
Threshold above which an over current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.15.3.4.10INTEGER (0..110)read-writemandatory
xPDUSystemOutputOverCurrentNeutralThreshold
OBJECT-TYPE
Threshold above which an Over current neutral condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.15.3.4.11INTEGER (0..110)read-writemandatory
xPDUSystemOutputUnderCurrentThreshold
OBJECT-TYPE
Threshold below which an under current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.15.3.4.12INTEGER (0..100)read-writemandatory
xPDUSystemOutputTableSize
OBJECT-TYPE
The number of System Output phase entries.
1.3.6.1.4.1.318.1.1.15.3.4.13INTEGERread-onlymandatory
xPDUSystemOutputPhaseTable
OBJECT-TYPE
A list of system output table entries. The number of entries is contained in the xPDUSystemOutputTableSize OID.
1.3.6.1.4.1.318.1.1.15.3.4.14not-accessiblemandatory
xPDUSystemOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular system output phase.
1.3.6.1.4.1.318.1.1.15.3.4.14.1not-accessiblemandatory
xPDUSystemOutputPhaseIndex
OBJECT-TYPE
Description of each output phase entry in the table.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xPDUSystemOutputVoltageLtoL
OBJECT-TYPE
Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.2INTEGERread-onlymandatory
xPDUSystemOutputVoltageLtoN
OBJECT-TYPE
Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.3INTEGERread-onlymandatory
xPDUSystemOutputPhaseCurrent
OBJECT-TYPE
System load current per phase. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.4INTEGERread-onlymandatory
xPDUSystemOutputPower
OBJECT-TYPE
System output power per phase. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.5INTEGERread-onlymandatory
xPDUSystemOutputApparentPower
OBJECT-TYPE
System output power per phase. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.6INTEGERread-onlymandatory
xPDUSystemOutputPowerFactor
OBJECT-TYPE
Indicates the Power Factor of the system output per phase. A value of 100 representing a unity Power Factor (1.00). Measured in hundredths.
1.3.6.1.4.1.318.1.1.15.3.4.14.1.7INTEGERread-onlymandatory
xPDUGroundMonitorPoint
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.3.5
xPDUGroundCurrent
OBJECT-TYPE
Shows the current measured in the earth ground conductor. Measured in tenths of Amps, or -1 if not available.
1.3.6.1.4.1.318.1.1.15.3.5.1INTEGERread-onlymandatory
xPDUGroundCurrentThreshold
OBJECT-TYPE
Threshold above which a ground current over current condition will be generated. Specified in tenths of Amps.
1.3.6.1.4.1.318.1.1.15.3.5.2INTEGER (0..50)read-writemandatory
xPDUCircuitBreakers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.4
xPDUSystemBreakers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.4.1
xPDUSystemBreakerTableSize
OBJECT-TYPE
The number of system breaker entries.
1.3.6.1.4.1.318.1.1.15.4.1.1INTEGERread-onlymandatory
xPDUSystemBreakerTable
OBJECT-TYPE
A list of system breaker entries. The number of entries is contained in the xPDUSystemBreakerTableSize OID.
1.3.6.1.4.1.318.1.1.15.4.1.2not-accessiblemandatory
xPDUSystemBreakerEntry
OBJECT-TYPE
An entry containing information applicable to a particular system breaker.
1.3.6.1.4.1.318.1.1.15.4.1.2.1not-accessiblemandatory
xPDUSystemBreakerTableIndex
OBJECT-TYPE
Index of system breaker entries in the table.
1.3.6.1.4.1.318.1.1.15.4.1.2.1.1INTEGERread-onlymandatory
xPDUSystemBreakerDescription
OBJECT-TYPE
A brief description of the system breakers.
1.3.6.1.4.1.318.1.1.15.4.1.2.1.2DisplayString (SIZE(0..79))read-onlymandatory
xPDUSystemBreakerPosition
OBJECT-TYPE
Indicates whether this breaker is open(1) or closed(2).
1.3.6.1.4.1.318.1.1.15.4.1.2.1.3INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
xPDUBranchBreakers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.4.2
xPDUNumOfBranchBreakers
OBJECT-TYPE
The number of branch breakers (panel positions) in the Panel. returns 42 for a 1-panel or 84 for a 2-panel system.
1.3.6.1.4.1.318.1.1.15.4.2.1INTEGERread-onlymandatory
xPDUBranchBreakerTableSize
OBJECT-TYPE
The number of branch breaker entries determined by the xPDUNumOfBranchBreakers OID.
1.3.6.1.4.1.318.1.1.15.4.2.2INTEGERread-onlymandatory
xPDUBranchBreakerTable
OBJECT-TYPE
A list of branch breaker table entries. The number of entries is given by the value of xPDUBranchBreakerTableSize The number of entries is contained in the xPDUBranchBreakerTableSize OID.
1.3.6.1.4.1.318.1.1.15.4.2.3not-accessiblemandatory
xPDUBranchBreakerEntry
OBJECT-TYPE
An entry containing information applicable to a particular branch breaker (panel position).
1.3.6.1.4.1.318.1.1.15.4.2.3.1not-accessiblemandatory
xPDUBranchBreakerTableIndex
OBJECT-TYPE
Index of branch breaker entries in the table.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.1INTEGERread-onlymandatory
xPDUBranchBreakerRating
OBJECT-TYPE
Indicates current rating of this breaker. 0=Breaker is not present. 1=Earth leakage connection. 2=Neutral connection. A value greater than 2 indicates breaker current rating in Amps. A value above 60 Amp will signify a remote feed. The xPDUBranchBreakerRDPFeed OID will indicate which breakers are configured as a remote drop. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.2INTEGERread-writemandatory
xPDUBranchBreakerRDPFeed
OBJECT-TYPE
Indicates that a breaker position is feeding a remote distribution panel.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.3INTEGER {remoteDistribution(1), noRemoteDistribution(2)}read-onlymandatory
xPDUBranchBreakerTieIndicator
OBJECT-TYPE
Indicates whether or not the breaker in this position is logically associated with the breaker immediately below it. This setting is used grouping the breakers feeding a multi-pole branch circuit. Note: When setting an entry's branch breaker tie indicator to breakerTied, all the positions that are tied to this breaker will take on the rating and thresholds for this entry of the table.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.4INTEGER {breakerUnTied(1), breakerTied(2)}read-writemandatory
xPDUBranchBreakerCurrent
OBJECT-TYPE
Indicates the branch current in tenths of Amps or -1 when not available.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.5INTEGERread-onlymandatory
xPDUBranchBreakerOverCurrentThreshold
OBJECT-TYPE
Threshold above which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.6INTEGER (0..100)read-writemandatory
xPDUBranchBreakerUnderCurrentThreshold
OBJECT-TYPE
Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.7INTEGER (0..100)read-writemandatory
xPDUBranchBreakerMaxCurrentThreshold
OBJECT-TYPE
Threshold above which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.8INTEGER (0..100)read-writemandatory
xPDUBranchBreakerMinCurrentThreshold
OBJECT-TYPE
Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch circuit thresholds/ratings for an entry, all positions tied (see the xPDUBranchBreakerTieIndicator OID) to this entry will inherit the new threshold/rating.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.9INTEGER (0..100)read-writemandatory
xPDUBranchBreakerName
OBJECT-TYPE
The description of the purpose/use of the breaker.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.10DisplayStringread-writemandatory
xPDUBranchBreakerLocation
OBJECT-TYPE
The description of the location of the breaker.
1.3.6.1.4.1.318.1.1.15.4.2.3.1.11DisplayStringread-writemandatory
xPDUInputContacts
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.5
xPDUInputContactNumContacts
OBJECT-TYPE
The number of contacts supported by the PDU.
1.3.6.1.4.1.318.1.1.15.5.1INTEGERread-onlymandatory
xPDUInputContactTableSize
OBJECT-TYPE
The number of input contact entries.
1.3.6.1.4.1.318.1.1.15.5.2INTEGERread-onlymandatory
xPDUInputContactTable
OBJECT-TYPE
A list of contacts supported by the PDU. The number of entries is contained in the xPDUInputContactTableSize OID.
1.3.6.1.4.1.318.1.1.15.5.3not-accessiblemandatory
xPDUInputContactEntry
OBJECT-TYPE
A contact entry containing information for a given contact.
1.3.6.1.4.1.318.1.1.15.5.3.1not-accessiblemandatory
xPDUInputContactNumber
OBJECT-TYPE
An index identifying the contact on the PDU.
1.3.6.1.4.1.318.1.1.15.5.3.1.1INTEGERread-onlymandatory
xPDUInputContactName
OBJECT-TYPE
The description of the purpose/use of the contact.
1.3.6.1.4.1.318.1.1.15.5.3.1.2DisplayStringread-writemandatory
xPDUInputContactNormalState
OBJECT-TYPE
The normal operating position of the contact.
1.3.6.1.4.1.318.1.1.15.5.3.1.3INTEGER {open(1), closed(2)}read-writemandatory
xPDUInputContactCurrentState
OBJECT-TYPE
This value indicates the current state of the contact.
1.3.6.1.4.1.318.1.1.15.5.3.1.4INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
xPDUOutputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.6
xPDUOutputRelaysNumRelays
OBJECT-TYPE
The number of output relays supported by the PDU.
1.3.6.1.4.1.318.1.1.15.6.1INTEGERread-onlymandatory
xPDUOutputRelaysTableSize
OBJECT-TYPE
The number of output relay entries.
1.3.6.1.4.1.318.1.1.15.6.2INTEGERread-onlymandatory
xPDUOutputRelayTable
OBJECT-TYPE
A list of output relays supported by the PDU. The number of entries is contained in the xPDUOutputRelayTableSize OID.
1.3.6.1.4.1.318.1.1.15.6.3not-accessiblemandatory
xPDUOutputRelayEntry
OBJECT-TYPE
A output relay entry containing information for a given contact.
1.3.6.1.4.1.318.1.1.15.6.3.1not-accessiblemandatory
xPDUOutputRelayNumber
OBJECT-TYPE
An index identifying the output relay on the PDU.
1.3.6.1.4.1.318.1.1.15.6.3.1.1INTEGERread-onlymandatory
xPDUOutputRelayName
OBJECT-TYPE
The description of the purpose/use of the output relay.
1.3.6.1.4.1.318.1.1.15.6.3.1.2DisplayStringread-writemandatory
xPDUOutputRelayNormalState
OBJECT-TYPE
The normal operating position of the output relay.
1.3.6.1.4.1.318.1.1.15.6.3.1.3INTEGER {open(1), closed(2)}read-writemandatory
xPDUOutputRelayCurrentState
OBJECT-TYPE
This value indicates the current state of the output relay.
1.3.6.1.4.1.318.1.1.15.6.3.1.4INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
xPDUMiscGroup
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.15.7
xPDUEPOMode
OBJECT-TYPE
Indicates whether the EPO System is armed(1) or disarmed(2).
1.3.6.1.4.1.318.1.1.15.7.1INTEGER {armed(1), disarmed(2), unknown(3)}read-onlymandatory
xPDUTransformTempStatus
OBJECT-TYPE
Indicates if the PDU's isolation transformer is over temperature.
1.3.6.1.4.1.318.1.1.15.7.2INTEGER {normal(1), overtemp(2), noTransformerPresent(3), unknown(4)}read-onlymandatory
xPDUCoolingFanStatus
OBJECT-TYPE
Indicates if one or more of the PDU's cooling fans have failed.
1.3.6.1.4.1.318.1.1.15.7.3INTEGER {normal(1), failed(2), noCoolingFansPresent(3), unknown(4)}read-onlymandatory
battMan
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16
battManIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.1
battManIdentProductName
OBJECT-TYPE
The name of the battery manager.
1.3.6.1.4.1.318.1.1.16.1.1DisplayStringread-writemandatory
battManIdentHardwareRev
OBJECT-TYPE
The battery manager network interface hardware revision. This value is set at the factory.
1.3.6.1.4.1.318.1.1.16.1.2DisplayStringread-onlymandatory
battManIdentFirmwareRev
OBJECT-TYPE
The battery manager network interface firmware revision. This value is set at the factory and can change with firmware update.
1.3.6.1.4.1.318.1.1.16.1.3DisplayStringread-onlymandatory
battManIdentDateOfManufacture
OBJECT-TYPE
The date the battery manager was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.16.1.4DisplayStringread-onlymandatory
battManIdentModelNumber
OBJECT-TYPE
The battery manager model number character string. This value is set at the factory.
1.3.6.1.4.1.318.1.1.16.1.5DisplayStringread-onlymandatory
battManIdentSerialNumber
OBJECT-TYPE
The battery manager serial number character string. This value is set at the factory.
1.3.6.1.4.1.318.1.1.16.1.6DisplayStringread-onlymandatory
battManSystemCalib
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.2
battManOhmicValueCorrectionFactor
OBJECT-TYPE
The system ohmic value correction factor in percent.
1.3.6.1.4.1.318.1.1.16.2.1INTEGERread-writemandatory
battManUnitCalib
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.3
battManUnitCalibTableSize
OBJECT-TYPE
The number of entries in the battManUnitCalibTable.
1.3.6.1.4.1.318.1.1.16.3.1INTEGERread-onlymandatory
battManUnitCalibTable
OBJECT-TYPE
Allows for getting calibration information from each unit in the system.
1.3.6.1.4.1.318.1.1.16.3.2not-accessiblemandatory
battManUnitCalibEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.16.3.2.1not-accessiblemandatory
battManUnitCalibIndex
OBJECT-TYPE
Index of unit calibration entries in the table.
1.3.6.1.4.1.318.1.1.16.3.2.1.1INTEGERread-onlymandatory
battManUnitSerialNumber
OBJECT-TYPE
The serial number of the unit.
1.3.6.1.4.1.318.1.1.16.3.2.1.2DisplayStringread-onlymandatory
battManBatteryVoltageZeroCalib
OBJECT-TYPE
The unit battery voltage zero calibration in millivolts.
1.3.6.1.4.1.318.1.1.16.3.2.1.3INTEGERread-writemandatory
battManBatteryVoltageSpanCalib
OBJECT-TYPE
The unit battery voltage span calibration in hundredths of percent.
1.3.6.1.4.1.318.1.1.16.3.2.1.4INTEGERread-writemandatory
battManStringCalib
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.4
battManStringCalibTableSize
OBJECT-TYPE
The number of entries in the battManStringCalibTable.
1.3.6.1.4.1.318.1.1.16.4.1INTEGERread-onlymandatory
battManStringCalibTable
OBJECT-TYPE
Allows for getting calibration information from each string in the system.
1.3.6.1.4.1.318.1.1.16.4.2not-accessiblemandatory
battManStringCalibEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.4.2.1not-accessiblemandatory
battManStringCalibIndex
OBJECT-TYPE
Index of string calibration entries in the table.
1.3.6.1.4.1.318.1.1.16.4.2.1.1INTEGERread-onlymandatory
battManDCCurrentZeroCalib
OBJECT-TYPE
The string DC current zero calibration in tenths of amps.
1.3.6.1.4.1.318.1.1.16.4.2.1.2INTEGERread-writemandatory
battManACCurrentZeroCalib
OBJECT-TYPE
The string AC current zero calibration in tenths of amps.
1.3.6.1.4.1.318.1.1.16.4.2.1.3INTEGERread-writemandatory
battManProbeRange
OBJECT-TYPE
The string probe range in amps.
1.3.6.1.4.1.318.1.1.16.4.2.1.4INTEGER {amps1000(1), amps500(2), amps100(3), amps200(4), amps2000(5)}read-writemandatory
battManBatteryCalib
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.5
battManString1BatteryCalibTableSize
OBJECT-TYPE
The number of entries in the battManString1BatteryCalibTable.
1.3.6.1.4.1.318.1.1.16.5.1INTEGERread-onlymandatory
battManString1BatteryCalibTable
OBJECT-TYPE
Allows for getting calibration information from each battery in String 1.
1.3.6.1.4.1.318.1.1.16.5.2not-accessiblemandatory
battManString1BatteryCalibEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.5.2.1not-accessiblemandatory
battManString1BatteryCalibIndex
OBJECT-TYPE
Index of battery calibration entries in the table.
1.3.6.1.4.1.318.1.1.16.5.2.1.1INTEGERread-onlymandatory
battManString1BatteryInterTierOhmicValue
OBJECT-TYPE
The battery inter-tier ohmic value in ohms. This corresponds to the ohmic value for the positive terminal of the battery.
1.3.6.1.4.1.318.1.1.16.5.2.1.2INTEGERread-writemandatory
battManString2BatteryCalibTableSize
OBJECT-TYPE
The number of entries in the battManString2BatteryCalibTable.
1.3.6.1.4.1.318.1.1.16.5.3INTEGERread-onlymandatory
battManString2BatteryCalibTable
OBJECT-TYPE
Allows for getting calibration information from each battery in String 2.
1.3.6.1.4.1.318.1.1.16.5.4not-accessiblemandatory
battManString2BatteryCalibEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.5.4.1not-accessiblemandatory
battManString2BatteryCalibIndex
OBJECT-TYPE
Index of battery calibration entries in the table.
1.3.6.1.4.1.318.1.1.16.5.4.1.1INTEGERread-onlymandatory
battManString2BatteryInterTierOhmicValue
OBJECT-TYPE
The battery inter-tier ohmic value in ohms.
1.3.6.1.4.1.318.1.1.16.5.4.1.2INTEGERread-writemandatory
battManConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.6
battManConfigApplication
OBJECT-TYPE
This OID has been deprecated.
1.3.6.1.4.1.318.1.1.16.6.1INTEGER {silcon(1), other(2)}read-writedeprecated
battManConfigBatteryChemistry
OBJECT-TYPE
The battery chemistry of the monitored batteries: LeadAcid(1) Lead Acid or Nickel-Cadmium(2) Nickel-Cadmium.
1.3.6.1.4.1.318.1.1.16.6.2INTEGER {leadAcid(1), nickel-Cadmium(2)}read-writemandatory
battManConfigBatteryAHCapacity
OBJECT-TYPE
The amp hour capacity of the monitored batteries 5-4000 AH.
1.3.6.1.4.1.318.1.1.16.6.3INTEGERread-writemandatory
battManConfigNumberofStrings
OBJECT-TYPE
The number of strings in the battery manager system.
1.3.6.1.4.1.318.1.1.16.6.4INTEGERread-writemandatory
battManConfigBatteriesperString
OBJECT-TYPE
The number of batteries per string.
1.3.6.1.4.1.318.1.1.16.6.5INTEGERread-writemandatory
battManConfigCellsperBattery
OBJECT-TYPE
The number of cells per battery (1, 2, 4 or 6 for lead-acid, 1 or 2 for NiCd.
1.3.6.1.4.1.318.1.1.16.6.6INTEGER {oneCell(1), twoCells(2), fourCells(4), sixCells(6)}read-writemandatory
battManConfigMinCellVoltage
OBJECT-TYPE
The minimum battery cell voltage alarm limit in millivolts DC.
1.3.6.1.4.1.318.1.1.16.6.7INTEGERread-writemandatory
battManConfigMaxCellVoltage
OBJECT-TYPE
The maximum battery cell voltage alarm limit in millivolts DC.
1.3.6.1.4.1.318.1.1.16.6.8INTEGERread-writemandatory
battManConfigMaxPilotTempF
OBJECT-TYPE
The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.16.6.9INTEGERread-writemandatory
battManConfigMaxPilotTempC
OBJECT-TYPE
The maximum pilot battery temperature alarm limit in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.16.6.10INTEGERread-writemandatory
battManConfigMaxAmbientTempF
OBJECT-TYPE
The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.16.6.11INTEGERread-writemandatory
battManConfigMaxAmbientTempC
OBJECT-TYPE
The maximum ambient temperature alarm limit in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.16.6.12INTEGERread-writemandatory
battManConfigMinAmbientTempF
OBJECT-TYPE
The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.16.6.13INTEGERread-writemandatory
battManConfigMinAmbientTempC
OBJECT-TYPE
The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.16.6.14INTEGERread-writemandatory
battManConfigMaxRippleCurrent
OBJECT-TYPE
The maximum ripple current alarm limit for the monitored battery strings in percent of AH capacity.
1.3.6.1.4.1.318.1.1.16.6.15INTEGERread-writemandatory
battManConfigMaxCurrentAcceptanceDeviation
OBJECT-TYPE
The maximum current acceptance deviation alarm limit in percent.
1.3.6.1.4.1.318.1.1.16.6.16INTEGERread-writemandatory
battManConfigMonitorWireLength
OBJECT-TYPE
The monitor wire length: fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet.
1.3.6.1.4.1.318.1.1.16.6.17INTEGER {fiftyFeetOrLess(1), moreThanFiftyFeet(2)}read-writemandatory
battManConfigDischargeVoltageAlarmLevel
OBJECT-TYPE
The discharge voltage alarm level in percent.
1.3.6.1.4.1.318.1.1.16.6.18INTEGERread-writemandatory
battManConfigAutoAnnunciatorReset
OBJECT-TYPE
The annunciator output signal reset method: disabled(1) means the annunciator signal output will be reset when the reset button is pressed. enabled(2) means the annunciator will stop signaling when all alarm conditions clear.
1.3.6.1.4.1.318.1.1.16.6.19INTEGER {disabled(1), enabled(2)}read-writemandatory
battManConfigSuspendCellVoltage
OBJECT-TYPE
This is used along with the number of cells per battery and the number of batteries per string to determine if a battery string has violated the low voltage limit. If so, the Battery Management System will enter suspend mode. Measured in millivolts DC
1.3.6.1.4.1.318.1.1.16.6.20INTEGERread-writemandatory
battManConfigOhmicTestWaitTime
OBJECT-TYPE
The amount of time in seconds after a discharge event before data will be collected for the ohmic value calculation.
1.3.6.1.4.1.318.1.1.16.6.21INTEGERread-writemandatory
battManConfigNumberOfBoosts
OBJECT-TYPE
The number of consecutive times the Battery Management System applies a charge to each battery during a boost cycle. Batteries with a Rated Battery AH Capacity less than or equal to 120 AH will always have a value of one for Number of Boosts.
1.3.6.1.4.1.318.1.1.16.6.22INTEGERread-writemandatory
battManAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.7
battManAlarmManagementController
OBJECT-TYPE
The Management Controller Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
1.3.6.1.4.1.318.1.1.16.7.1INTEGER {normal(1), alarm(2)}read-onlymandatory
battManAlarmBatteries
OBJECT-TYPE
The Batteries Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
1.3.6.1.4.1.318.1.1.16.7.2INTEGER {normal(1), alarm(2)}read-onlymandatory
battManAlarmCharger
OBJECT-TYPE
The Charger Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
1.3.6.1.4.1.318.1.1.16.7.3INTEGER {normal(1), alarm(2)}read-onlymandatory
battManAlarmEnvironment
OBJECT-TYPE
The Environment Alarm is : normal(1) no alarm conditions identified alarm(2) an alarm condition exists.
1.3.6.1.4.1.318.1.1.16.7.4INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.8
battManSystemAmbientTempC
OBJECT-TYPE
The system ambient temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.16.8.1INTEGERread-onlymandatory
battManSystemAmbientTempF
OBJECT-TYPE
The system ambient temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.16.8.2INTEGERread-onlymandatory
battManSystemPilotTempC
OBJECT-TYPE
The system pilot temperature in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.16.8.3INTEGERread-onlymandatory
battManSystemPilotTempF
OBJECT-TYPE
The system pilot temperature in tenths of degrees Fahrenheit.
1.3.6.1.4.1.318.1.1.16.8.4INTEGERread-onlymandatory
battManSystemAmbientHighTempAlarm
OBJECT-TYPE
When set to alarm(2), indicates that the system has a high temperature alarm.
1.3.6.1.4.1.318.1.1.16.8.5INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemAmbientLowTempAlarm
OBJECT-TYPE
When set to alarm(2), indicates that the system has a low temperature alarm.
1.3.6.1.4.1.318.1.1.16.8.6INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemPilotBatteryHighTempAlarm
OBJECT-TYPE
When set to alarm(2), indicates that the system has a pilot battery high temperature alarm.
1.3.6.1.4.1.318.1.1.16.8.7INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemPilotProbeDisconnected
OBJECT-TYPE
When set to alarm(2), indicates that the system pilot probe is disconnected.
1.3.6.1.4.1.318.1.1.16.8.8INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemAmbientProbeDisconnected
OBJECT-TYPE
When set to alarm(2), indicates that the system ambient probe is disconnected.
1.3.6.1.4.1.318.1.1.16.8.9INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemConfigurationInvalid
OBJECT-TYPE
When set to alarm(2), indicates that the system is not configured correctly.
1.3.6.1.4.1.318.1.1.16.8.10INTEGER {normal(1), alarm(2)}read-onlymandatory
battManSystemSuspendVoltage
OBJECT-TYPE
When set to alarm(2), indicates that the system has suspended voltage scans.
1.3.6.1.4.1.318.1.1.16.8.11INTEGER {normal(1), alarm(2)}read-onlymandatory
battManStringStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.9
battManStringTableSize
OBJECT-TYPE
The number of entries in the battManStringTable.
1.3.6.1.4.1.318.1.1.16.9.1INTEGERread-onlymandatory
battManStringTable
OBJECT-TYPE
Allows for getting information from each string in the system.
1.3.6.1.4.1.318.1.1.16.9.2not-accessiblemandatory
battManStringEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.9.2.1not-accessiblemandatory
battManStringIndex
OBJECT-TYPE
Index of string entries in the table.
1.3.6.1.4.1.318.1.1.16.9.2.1.1INTEGERread-onlymandatory
battManStringCurrent
OBJECT-TYPE
The string current in tenths of amps.
1.3.6.1.4.1.318.1.1.16.9.2.1.2INTEGERread-onlymandatory
battManStringRippleCurrent
OBJECT-TYPE
The string ripple current in tenths of amps.
1.3.6.1.4.1.318.1.1.16.9.2.1.3INTEGERread-onlymandatory
battManStringChargerHighVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates that the string charger has a high voltage alarm.
1.3.6.1.4.1.318.1.1.16.9.2.1.4INTEGER {normal(1), alarm(2)}read-onlymandatory
battManStringChargerLowVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates that the string charger has a low voltage alarm.
1.3.6.1.4.1.318.1.1.16.9.2.1.5INTEGER {normal(1), alarm(2)}read-onlymandatory
battManStringCurrentProbeDisconnected
OBJECT-TYPE
When set to alarm(2), indicates that the string charger probe is disconnected.
1.3.6.1.4.1.318.1.1.16.9.2.1.6INTEGER {normal(1), alarm(2)}read-onlymandatory
battManStringOnBattery
OBJECT-TYPE
When set to alarm(2), indicates that the string is in the on-battery state.
1.3.6.1.4.1.318.1.1.16.9.2.1.7INTEGER {normal(1), alarm(2)}read-onlymandatory
battManStringHighRippleCurrent
OBJECT-TYPE
When set to alarm(2), indicates that the string has a high ripple current.
1.3.6.1.4.1.318.1.1.16.9.2.1.8INTEGER {normal(1), alarm(2)}read-onlymandatory
battManStringVoltage
OBJECT-TYPE
The sum of the voltages for all of the batteries on a string in millivolts DC.
1.3.6.1.4.1.318.1.1.16.9.2.1.9INTEGERread-onlymandatory
battManStringDischargeLess5Seconds
OBJECT-TYPE
The number of recorded discharges lasting less than 5 seconds.
1.3.6.1.4.1.318.1.1.16.9.2.1.10INTEGERread-onlymandatory
battManStringDischarge5to10Seconds
OBJECT-TYPE
The number of recorded discharges lasting between 5 and 10 seconds.
1.3.6.1.4.1.318.1.1.16.9.2.1.11INTEGERread-onlymandatory
battManStringDischarge10to60Seconds
OBJECT-TYPE
The number of recorded discharges lasting between 10 and 60 seconds.
1.3.6.1.4.1.318.1.1.16.9.2.1.12INTEGERread-onlymandatory
battManStringDischargeMore60Seconds
OBJECT-TYPE
The number of recorded discharges lasting more than 60 seconds (1 minute).
1.3.6.1.4.1.318.1.1.16.9.2.1.13INTEGERread-onlymandatory
battManBatteryStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.10
battManString1BatteryTableSize
OBJECT-TYPE
The number of entries in the battManString1BatteryTable.
1.3.6.1.4.1.318.1.1.16.10.1INTEGERread-onlymandatory
battManString1BatteryTable
OBJECT-TYPE
Allows for getting information from each string in the system.
1.3.6.1.4.1.318.1.1.16.10.2not-accessiblemandatory
battManString1BatteryEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.10.2.1not-accessiblemandatory
battManString1BatteryIndex
OBJECT-TYPE
Index of string entries in the table.
1.3.6.1.4.1.318.1.1.16.10.2.1.1INTEGERread-onlymandatory
battManString1BatteryVoltage
OBJECT-TYPE
The battery voltage in millivolts DC.
1.3.6.1.4.1.318.1.1.16.10.2.1.2INTEGERread-onlymandatory
battManString1BatteryLowestVoltage
OBJECT-TYPE
The lowest battery discharge voltage during the last power event in millivolts DC.
1.3.6.1.4.1.318.1.1.16.10.2.1.3INTEGERread-onlymandatory
battManString1BatteryCellShorted
OBJECT-TYPE
When set to alarm(2), indicates that a battery cell is shorted.
1.3.6.1.4.1.318.1.1.16.10.2.1.4INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryOpenFuseOrConnection
OBJECT-TYPE
When set to alarm(2), indicates that a fuse or connection is open.
1.3.6.1.4.1.318.1.1.16.10.2.1.5INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryLowCapacity
OBJECT-TYPE
When set to alarm(2), indicates a battery has low capacity.
1.3.6.1.4.1.318.1.1.16.10.2.1.6INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryHighOhmicValue
OBJECT-TYPE
When set to alarm(2), indicates a battery has a high ohmic value.
1.3.6.1.4.1.318.1.1.16.10.2.1.7INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryThermalRunaway
OBJECT-TYPE
When set to alarm(2), indicates a battery has a thermal runaway condition.
1.3.6.1.4.1.318.1.1.16.10.2.1.8INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryDryout
OBJECT-TYPE
When set to alarm(2), indicates a battery has a dryout condition.
1.3.6.1.4.1.318.1.1.16.10.2.1.9INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryUserHighVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the user level high voltage limit.
1.3.6.1.4.1.318.1.1.16.10.2.1.10INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryUserLowVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the user level low voltage limit.
1.3.6.1.4.1.318.1.1.16.10.2.1.11INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryChemHighVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit.
1.3.6.1.4.1.318.1.1.16.10.2.1.12INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryChemLowVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit.
1.3.6.1.4.1.318.1.1.16.10.2.1.13INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString1BatteryOpenCell
OBJECT-TYPE
When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal.
1.3.6.1.4.1.318.1.1.16.10.2.1.14INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryTableSize
OBJECT-TYPE
The number of entries in the battManString2BatteryTable.
1.3.6.1.4.1.318.1.1.16.10.3INTEGERread-onlymandatory
battManString2BatteryTable
OBJECT-TYPE
Allows for getting information from each string in the system.
1.3.6.1.4.1.318.1.1.16.10.4not-accessiblemandatory
battManString2BatteryEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.10.4.1not-accessiblemandatory
battManString2BatteryIndex
OBJECT-TYPE
Index of string entries in the table.
1.3.6.1.4.1.318.1.1.16.10.4.1.1INTEGERread-onlymandatory
battManString2BatteryVoltage
OBJECT-TYPE
The battery voltage in millivolts DC.
1.3.6.1.4.1.318.1.1.16.10.4.1.2INTEGERread-onlymandatory
battManString2BatteryLowestVoltage
OBJECT-TYPE
The lowest battery discharge voltage during the last power event in millivolts DC.
1.3.6.1.4.1.318.1.1.16.10.4.1.3INTEGERread-onlymandatory
battManString2BatteryCellShorted
OBJECT-TYPE
When set to alarm(2), indicates that a battery cell is shorted.
1.3.6.1.4.1.318.1.1.16.10.4.1.4INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryOpenFuseOrConnection
OBJECT-TYPE
When set to alarm(2), indicates that a fuse or connection is open.
1.3.6.1.4.1.318.1.1.16.10.4.1.5INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryLowCapacity
OBJECT-TYPE
When set to alarm(2), indicates a battery has low capacity.
1.3.6.1.4.1.318.1.1.16.10.4.1.6INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryHighOhmicValue
OBJECT-TYPE
When set to alarm(2), indicates a battery has a high ohmic value.
1.3.6.1.4.1.318.1.1.16.10.4.1.7INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryThermalRunaway
OBJECT-TYPE
When set to alarm(2), indicates a battery has a thermal runaway condition.
1.3.6.1.4.1.318.1.1.16.10.4.1.8INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryDryout
OBJECT-TYPE
When set to alarm(2), indicates a battery has a dryout condition.
1.3.6.1.4.1.318.1.1.16.10.4.1.9INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryUserHighVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the user level high voltage limit.
1.3.6.1.4.1.318.1.1.16.10.4.1.10INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryUserLowVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the user level low voltage limit.
1.3.6.1.4.1.318.1.1.16.10.4.1.11INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryChemHighVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the chemistry level high voltage limit.
1.3.6.1.4.1.318.1.1.16.10.4.1.12INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryChemLowVoltageAlarm
OBJECT-TYPE
When set to alarm(2), indicates a battery has violated the chemistry level low voltage limit.
1.3.6.1.4.1.318.1.1.16.10.4.1.13INTEGER {normal(1), alarm(2)}read-onlymandatory
battManString2BatteryOpenCell
OBJECT-TYPE
When set to alarm(2), indicates the battery has an open cell or an inter-connection is abnormal.
1.3.6.1.4.1.318.1.1.16.10.4.1.14INTEGER {normal(1), alarm(2)}read-onlymandatory
battManInputContactStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.11
battManInputContactTableSize
OBJECT-TYPE
The number of entries in the battManInputContactTable.
1.3.6.1.4.1.318.1.1.16.11.1INTEGERread-onlymandatory
battManInputContactTable
OBJECT-TYPE
Allows for getting information from each contact in the system.
1.3.6.1.4.1.318.1.1.16.11.2not-accessiblemandatory
battManInputContactEntry
OBJECT-TYPE
The contact to get data from.
1.3.6.1.4.1.318.1.1.16.11.2.1not-accessiblemandatory
battManInputContactIndex
OBJECT-TYPE
Index of contact entries in the table.
1.3.6.1.4.1.318.1.1.16.11.2.1.1INTEGERread-onlymandatory
battManInputContactName
OBJECT-TYPE
The name of the input contact.
1.3.6.1.4.1.318.1.1.16.11.2.1.2DisplayStringread-writemandatory
battManInputContactAlarmState
OBJECT-TYPE
When set to alarm(2), indicates that the alarm condition is active for this contact.
1.3.6.1.4.1.318.1.1.16.11.2.1.3INTEGER {normal(1), alarm(2)}read-onlymandatory
battManInputContactState
OBJECT-TYPE
When set to open(1), the input contact is in the open state. When set to closed(2), the input contact is in the closed state.
1.3.6.1.4.1.318.1.1.16.11.2.1.4INTEGER {open(1), closed(2)}read-onlymandatory
battManInputContactNormalState
OBJECT-TYPE
When set to open(1), the input contact is normally open. When set to closed(2), the input contact is normally closed.
1.3.6.1.4.1.318.1.1.16.11.2.1.5INTEGER {open(1), closed(2)}read-writemandatory
battManInputContactAlarmDelay
OBJECT-TYPE
The input contact alarm delay time in seconds.
1.3.6.1.4.1.318.1.1.16.11.2.1.6INTEGERread-writemandatory
battManControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.12
battManRemoteAnnunciatorReset
OBJECT-TYPE
Setting this OID to reset(2) will reset the user interface annunciator. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.16.12.1INTEGER {noOperation(1), reset(2)}read-writemandatory
battManResetChargeCurrentDeviationBenchmark
OBJECT-TYPE
Setting this OID to reset(2) will reset the charge current deviation benchmark. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.16.12.2INTEGER {noOperation(1), reset(2)}read-writemandatory
battManResetLowestDischargeVoltages
OBJECT-TYPE
Setting this OID to reset(2) will reset the lowest discharge voltages. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.16.12.3INTEGER {noOperation(1), reset(2)}read-writemandatory
battManResetDischargeCounters
OBJECT-TYPE
Setting this OID to reset(2) will reset all discharge event counters. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.16.12.4INTEGER {noOperation(1), reset(2)}read-writemandatory
battManTestResults
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.13
battManString1OhmicValueLastDischargeInfo
OBJECT-TYPE
Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded.
1.3.6.1.4.1.318.1.1.16.13.1DisplayStringread-onlymandatory
battManString1OhmicValueTableSize
OBJECT-TYPE
The number of entries in the battManString1OhmicValueTable.
1.3.6.1.4.1.318.1.1.16.13.2INTEGERread-onlymandatory
battManString1OhmicValueTable
OBJECT-TYPE
Allows for getting ohmic value information from each battery in String 1.
1.3.6.1.4.1.318.1.1.16.13.3not-accessiblemandatory
battManString1OhmicValueEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.3.1not-accessiblemandatory
battManString1OhmicValueIndex
OBJECT-TYPE
The battery number.
1.3.6.1.4.1.318.1.1.16.13.3.1.1INTEGERread-onlymandatory
battManString1OhmicValueData
OBJECT-TYPE
The battery inter-tier ohmic value in tenths of milli-Ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors.
1.3.6.1.4.1.318.1.1.16.13.3.1.2INTEGERread-onlymandatory
battManString1ResponseTestChangeTableSize
OBJECT-TYPE
The number of entries in the battManString1ResponseTestChangeTable.
1.3.6.1.4.1.318.1.1.16.13.4INTEGERread-onlymandatory
battManString1ResponseTestChangeTable
OBJECT-TYPE
Allows for getting response test change information from each battery in String 1.
1.3.6.1.4.1.318.1.1.16.13.5not-accessiblemandatory
battManString1ResponseTestChangeEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.5.1not-accessiblemandatory
battManString1ResponseTestChangeIndex
OBJECT-TYPE
Index of the entries in the table.
1.3.6.1.4.1.318.1.1.16.13.5.1.1INTEGERread-onlymandatory
battManString1ResponseTestChangeData
OBJECT-TYPE
The battery response test change in percent.
1.3.6.1.4.1.318.1.1.16.13.5.1.2INTEGERread-onlymandatory
battManString2OhmicValueLastDischargeInfo
OBJECT-TYPE
Informational text showing the date/time, load, and pilot temperature for the string during the last discharge when ohmic values were recorded.
1.3.6.1.4.1.318.1.1.16.13.6DisplayStringread-onlymandatory
battManString2OhmicValueTableSize
OBJECT-TYPE
The number of entries in the battManString2OhmicValueTable.
1.3.6.1.4.1.318.1.1.16.13.7INTEGERread-onlymandatory
battManString2OhmicValueTable
OBJECT-TYPE
Allows for getting ohmic value information from each battery in String 2.
1.3.6.1.4.1.318.1.1.16.13.8not-accessiblemandatory
battManString2OhmicValueEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.8.1not-accessiblemandatory
battManString2OhmicValueIndex
OBJECT-TYPE
Index of battery calibration entries in the table.
1.3.6.1.4.1.318.1.1.16.13.8.1.1INTEGERread-onlymandatory
battManString2OhmicValueData
OBJECT-TYPE
The battery inter-tier ohmic value in ohms. Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors.
1.3.6.1.4.1.318.1.1.16.13.8.1.2INTEGERread-onlymandatory
battManString2ResponseTestChangeTableSize
OBJECT-TYPE
The number of entries in the battManString2ResponseTestChangeTable.
1.3.6.1.4.1.318.1.1.16.13.9INTEGERread-onlymandatory
battManString2ResponseTestChangeTable
OBJECT-TYPE
Allows for getting response test change information from each battery in String 2.
1.3.6.1.4.1.318.1.1.16.13.10not-accessiblemandatory
battManString2ResponseTestChangeEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.10.1not-accessiblemandatory
battManString2ResponseTestChangeIndex
OBJECT-TYPE
Index of the entries in the table.
1.3.6.1.4.1.318.1.1.16.13.10.1.1INTEGERread-onlymandatory
battManString2ResponseTestChangeData
OBJECT-TYPE
The battery response test change in percent.
1.3.6.1.4.1.318.1.1.16.13.10.1.2INTEGERread-onlymandatory
battManString1ResponseTestCurrentTableSize
OBJECT-TYPE
The number of entries in the battManString1ResponseTestCurrentTable.
1.3.6.1.4.1.318.1.1.16.13.11INTEGERread-onlymandatory
battManString1ResponseTestCurrentTable
OBJECT-TYPE
Allows for getting response test current information from each battery in String 1.
1.3.6.1.4.1.318.1.1.16.13.12not-accessiblemandatory
battManString1ResponseTestCurrentEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.12.1not-accessiblemandatory
battManString1ResponseTestCurrentIndex
OBJECT-TYPE
Index of the entries in the table.
1.3.6.1.4.1.318.1.1.16.13.12.1.1INTEGERread-onlymandatory
battManString1ResponseTestCurrentData
OBJECT-TYPE
The battery response test current in milliamps.
1.3.6.1.4.1.318.1.1.16.13.12.1.2INTEGERread-onlymandatory
battManString2ResponseTestCurrentTableSize
OBJECT-TYPE
The number of entries in the battManString2ResponseTestCurrentTable.
1.3.6.1.4.1.318.1.1.16.13.13INTEGERread-onlymandatory
battManString2ResponseTestCurrentTable
OBJECT-TYPE
Allows for getting response test current information from each battery in String 2.
1.3.6.1.4.1.318.1.1.16.13.14not-accessiblemandatory
battManString2ResponseTestCurrentEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.14.1not-accessiblemandatory
battManString2ResponseTestCurrentIndex
OBJECT-TYPE
Index of the entries in the table.
1.3.6.1.4.1.318.1.1.16.13.14.1.1INTEGERread-onlymandatory
battManString2ResponseTestCurrentData
OBJECT-TYPE
The battery response test current in milliamps.
1.3.6.1.4.1.318.1.1.16.13.14.1.2INTEGERread-onlymandatory
battManString1ResponseTestCurrentBenchmarkTableSize
OBJECT-TYPE
The number of entries in the battManString1ResponseTestCurrentBenchmarkTable.
1.3.6.1.4.1.318.1.1.16.13.15INTEGERread-onlymandatory
battManString1ResponseTestCurrentBenchmarkTable
OBJECT-TYPE
Allows for getting response test current benchmark information from each battery in String 1.
1.3.6.1.4.1.318.1.1.16.13.16not-accessiblemandatory
battManString1ResponseTestCurrentBenchmarkEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.16.1not-accessiblemandatory
battManString1ResponseTestCurrentBenchmarkIndex
OBJECT-TYPE
Index of the entries in the table.
1.3.6.1.4.1.318.1.1.16.13.16.1.1INTEGERread-onlymandatory
battManString1ResponseTestCurrentBenchmarkData
OBJECT-TYPE
The battery response test current benchmark in milliamps.
1.3.6.1.4.1.318.1.1.16.13.16.1.2INTEGERread-onlymandatory
battManString2ResponseTestCurrentBenchmarkTableSize
OBJECT-TYPE
The number of entries in the battManString2ResponseTestCurrentBenchmarkTable.
1.3.6.1.4.1.318.1.1.16.13.17INTEGERread-onlymandatory
battManString2ResponseTestCurrentBenchmarkTable
OBJECT-TYPE
Allows for getting response test current benchmark information from each battery in String 2.
1.3.6.1.4.1.318.1.1.16.13.18not-accessiblemandatory
battManString2ResponseTestCurrentBenchmarkEntry
OBJECT-TYPE
The string to get data from.
1.3.6.1.4.1.318.1.1.16.13.18.1not-accessiblemandatory
battManString2ResponseTestCurrentBenchmarkIndex
OBJECT-TYPE
Index of the entries in the table.
1.3.6.1.4.1.318.1.1.16.13.18.1.1INTEGERread-onlymandatory
battManString2ResponseTestCurrentBenchmarkData
OBJECT-TYPE
The battery response test current benchmark in milliamps.
1.3.6.1.4.1.318.1.1.16.13.18.1.2INTEGERread-onlymandatory
battManUnitStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.16.14
battManUnitStatusTableSize
OBJECT-TYPE
The number of entries in the battManUnitStatusTable.
1.3.6.1.4.1.318.1.1.16.14.1INTEGERread-onlymandatory
battManUnitStatusTable
OBJECT-TYPE
Allows for getting status information from each unit in the system.
1.3.6.1.4.1.318.1.1.16.14.2not-accessiblemandatory
battManUnitStatusEntry
OBJECT-TYPE
The unit to get data from.
1.3.6.1.4.1.318.1.1.16.14.2.1not-accessiblemandatory
battManUnitStatusIndex
OBJECT-TYPE
Index of unit status entries in the table.
1.3.6.1.4.1.318.1.1.16.14.2.1.1INTEGERread-onlymandatory
battManUnitStatusSerialNumber
OBJECT-TYPE
The battery manager unit serial number character string. This value is set at the factory.
1.3.6.1.4.1.318.1.1.16.14.2.1.2DisplayStringread-onlymandatory
battManUnitHardwareRev
OBJECT-TYPE
The battery manager unit hardware revision. This value is set at the factory.
1.3.6.1.4.1.318.1.1.16.14.2.1.3INTEGERread-onlymandatory
battManUnitFirmwareRev
OBJECT-TYPE
The battery manager unit firmware revision. This value is set at the factory and can change with firmware update.
1.3.6.1.4.1.318.1.1.16.14.2.1.4INTEGERread-onlymandatory
battManUnitCommLoss
OBJECT-TYPE
When set to alarm(2), indicates the system has lost communication with the unit.
1.3.6.1.4.1.318.1.1.16.14.2.1.5INTEGER {normal(1), alarm(2)}read-onlymandatory
battManUnitRelayStuck
OBJECT-TYPE
When set to alarm(2), indicates the unit monitor relay is stuck.
1.3.6.1.4.1.318.1.1.16.14.2.1.6INTEGER {normal(1), alarm(2)}read-onlymandatory
xATS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17
xATSIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.1
xATSIdentProductName
OBJECT-TYPE
The name of the transfer switch unit.
1.3.6.1.4.1.318.1.1.17.1.1DisplayStringread-writemandatory
xATSIdentHardwareRev
OBJECT-TYPE
The hardware revision of the transfer switch. This value is set at the factory.
1.3.6.1.4.1.318.1.1.17.1.2DisplayStringread-onlymandatory
xATSIdentFirmwareAppRev
OBJECT-TYPE
An ID string identifying the application firmware revision of the transfer switch.
1.3.6.1.4.1.318.1.1.17.1.3DisplayStringread-onlymandatory
xATSIdentFirmwareAppOSRev
OBJECT-TYPE
An ID string identifying the application operating system firmware revision of the transfer switch.
1.3.6.1.4.1.318.1.1.17.1.4DisplayStringread-onlymandatory
xATSIdentFirmwareControllerRev
OBJECT-TYPE
An ID string identifying the transfer switch controller firmware revision.
1.3.6.1.4.1.318.1.1.17.1.5DisplayStringread-onlymandatory
xATSIdentDateOfManufacture
OBJECT-TYPE
The date when the transfer switch was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.17.1.6DisplayStringread-onlymandatory
xATSIdentModelNumber
OBJECT-TYPE
A character string identifying the model number of the transfer switch. This value is set at the factory.
1.3.6.1.4.1.318.1.1.17.1.7DisplayStringread-onlymandatory
xATSIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the transfer switch. This value is set at the factory.
1.3.6.1.4.1.318.1.1.17.1.8DisplayStringread-onlymandatory
xATSDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.2
xATSDeviceServiceType
OBJECT-TYPE
The type of utility input to the transfer switch. Either 3 wires (delta), or 4 wires (wye).
1.3.6.1.4.1.318.1.1.17.2.1INTEGER {threeWire(1), fourWire(2)}read-onlymandatory
xATSDeviceNominalVoltage
OBJECT-TYPE
The nominal line-to-neutral system voltage. Measured in Volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available.
1.3.6.1.4.1.318.1.1.17.2.2INTEGERread-onlymandatory
xATSDeviceNominalFrequency
OBJECT-TYPE
The nominal system frequency. Measured in tenths of Hertz. -1 if not available.
1.3.6.1.4.1.318.1.1.17.2.3INTEGERread-onlymandatory
xATSDeviceTransferSwitchRating
OBJECT-TYPE
The rating of the transfer switch. Measured in Amps.
1.3.6.1.4.1.318.1.1.17.2.4INTEGERread-onlymandatory
xATSDeviceDCBackUpPresent
OBJECT-TYPE
Indicates if a DC backup is present or not.
1.3.6.1.4.1.318.1.1.17.2.5INTEGER {yes(1), no(2)}read-writemandatory
xATSSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.3
xATSSwitchStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.3.1
xATSSwitchStatusSelectedSource
OBJECT-TYPE
The source which is currently selected, i.e. supplying power to the load.
1.3.6.1.4.1.318.1.1.17.3.1.1INTEGER {none(1), source1(2), source2(3), fault(4), unknown(5)}read-onlymandatory
xATSSwitchStatusOperationalMode
OBJECT-TYPE
The current operating mode of the transfer switch. When the ATS is in automatic mode, generator starting and ATS transferring is all done automatically as needed based on the state of source 1. Automatic operation is halted when the ATS is in either of the notInAuto modes. A mode of notInAuto indicates that the automatic operation switch is in the disabled position, as indicated by the xATSSwitchStatusAutomaticOperationSwitch OID. The notInAutoAbnormal condition indicates that an abnormal condition has caused the transfer switch to halt automatic operation. In this case, traps can indicate the exact problem. In the case of notInAutoAbnormal, refer to the operation manual for details on how debug the condition and restore automatic operation.
1.3.6.1.4.1.318.1.1.17.3.1.2INTEGER {automatic(1), notInAutoAbnormal(2), notInAuto(3), unknown(4)}read-onlymandatory
xATSSwitchStatusAutomaticOperationSwitch
OBJECT-TYPE
The position of the automatic operation switch on the front of the transfer switch.
1.3.6.1.4.1.318.1.1.17.3.1.3INTEGER {disabled(1), enabled(2), unknown(3)}read-onlymandatory
xATSSwitchStatusEngineStartSignal
OBJECT-TYPE
The position of the Start/Stop contact which signals the generator engine to start/run. When the ATS is in automatic mode, generator starting/stopping is under ATS control.
1.3.6.1.4.1.318.1.1.17.3.1.4INTEGER {run(1), stop(2), unknown(3)}read-onlymandatory
xATSSwitchSettings
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.3.2
xATSSwitchSettingsLowVoltageTransferPoint
OBJECT-TYPE
The lowest acceptable voltage condition at source 1. When any phase of source 1 is lower than this voltage, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available.
1.3.6.1.4.1.318.1.1.17.3.2.1INTEGERread-writemandatory
xATSSwitchSettingsHighVoltageTransferPoint
OBJECT-TYPE
The highest acceptable voltage condition at source 1. When any phase of source 1 is greater than this voltage, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in volts, line-to-line for a 3-wire service or line-to-neutral for a 4-wire service. -1 if not available.
1.3.6.1.4.1.318.1.1.17.3.2.2INTEGERread-writemandatory
xATSSwitchSettingsMaxFrequencyDeviation
OBJECT-TYPE
The maximum acceptable frequency deviation condition from nominal at source 1. When source 1 frequency is outside the specified range, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified in tenths of Hertz above or below nominal. A value of zero indicates that frequency is ignored when determining source quality. -1 if not available.
1.3.6.1.4.1.318.1.1.17.3.2.3INTEGERread-writemandatory
xATSSwitchSettingsMinPhaseBalance
OBJECT-TYPE
The minimum required phase balance at source 1. When the percentage difference between the minimum and maximum phase voltage measurements at source 1 is greater than this value, source quality is considered bad and the generator run signal is asserted to begin generator operation. Specified as a percentage. A value of zero indicates that phase balance is ignored when determining source quality. -1 if not available.
1.3.6.1.4.1.318.1.1.17.3.2.4INTEGERread-writemandatory
xATSSwitchSettingsNominalRotation
OBJECT-TYPE
The nominal phase rotation (or phase sequence) required by the load. For certain types of equipment, such as rotating machinery, phase rotation is critical for proper operation as it determines the direction which motors will rotate (clockwise or counterclockwise). Source quality will be seen as bad if the rotation measured at that ATS input does not match this setting. If this setting is set to any, phase rotation is ignored.
1.3.6.1.4.1.318.1.1.17.3.2.5INTEGER {abc(1), cba(2), any(3), unknown(4)}read-writemandatory
xATSSwitchSettingsAllowClosedTransfer
OBJECT-TYPE
This setting enables seamless (closed) transfers between sources. When possible, both source 1 and source 2 are closed to the output for a brief time. If closed transfer is not possible within the amount of time specified by the xATSSwitchSettingsMaxSyncTime OID, an open transfer will be executed.
1.3.6.1.4.1.318.1.1.17.3.2.6INTEGER {yes(1), no(2), unknown(3)}read-writemandatory
xATSSwitchSettingsMaxSyncTime
OBJECT-TYPE
When attempting/seeking to perform a closed transfer, this setting defines the maximum time allowed before the transfer switch will give up and perform an open transfer. Specified in seconds. -1 if not available.
1.3.6.1.4.1.318.1.1.17.3.2.7INTEGERread-writemandatory
xATSSwitchSettingsNeutralTransferTime
OBJECT-TYPE
This setting defines how long both source 1 and source 2 will be disconnected from the output, during an open transfer. Specified in seconds. -1 if not available.
1.3.6.1.4.1.318.1.1.17.3.2.8INTEGERread-writemandatory
xATSSwitchSettingsClearLatchedAlarms
OBJECT-TYPE
Clears any latched alarm conditions.
1.3.6.1.4.1.318.1.1.17.3.2.9INTEGER {yes(1), no(2)}read-writemandatory
xATSSwitchSettingsSetToFactoryDefaults
OBJECT-TYPE
Sets all transfer switch settings to factory default values.
1.3.6.1.4.1.318.1.1.17.3.2.10INTEGER {yes(1), no(2)}read-writemandatory
xATSSwitchTimers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.3.3
xATSSwitchTimersTableSize
OBJECT-TYPE
The number of transfer switch timer entries.
1.3.6.1.4.1.318.1.1.17.3.3.1INTEGERread-onlymandatory
xATSSwitchTimersTable
OBJECT-TYPE
A list of timers supported by ATS. The number of entries is contained in the xATSSwitchTimersTableSize OID.
1.3.6.1.4.1.318.1.1.17.3.3.2not-accessiblemandatory
xATSSwitchTimersEntry
OBJECT-TYPE
An entry containing information about an individual ATS timer.
1.3.6.1.4.1.318.1.1.17.3.3.2.1not-accessiblemandatory
xATSSwitchTimersIndex
OBJECT-TYPE
Index of timer entries in the table.
1.3.6.1.4.1.318.1.1.17.3.3.2.1.1INTEGERread-onlymandatory
xATSSwitchTimersName
OBJECT-TYPE
Name of the individual timer.Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers.
1.3.6.1.4.1.318.1.1.17.3.3.2.1.2DisplayStringread-onlymandatory
xATSSwitchTimersAbort
OBJECT-TYPE
This aborts the individual timer.
1.3.6.1.4.1.318.1.1.17.3.3.2.1.3INTEGER {yes(1), no(2)}read-writemandatory
xATSSwitchTimersStatus
OBJECT-TYPE
The status of the individual timer. Designates whether this timer entry is currently running or inactive.
1.3.6.1.4.1.318.1.1.17.3.3.2.1.4INTEGER {inactive(1), active(2)}read-onlymandatory
xATSSwitchTimersRemainingTime
OBJECT-TYPE
The time remaining for this timer entry. Specified in seconds.
1.3.6.1.4.1.318.1.1.17.3.3.2.1.5INTEGERread-onlymandatory
xATSSwitchTimersDelaySetting
OBJECT-TYPE
The delay settings associated with this timer entry. When this timer entry is active, the timer value must exceed this setting before the ATS behavior associated with this timer is executed. Refer to ATS operation manual, or on-line help, for detailed descriptions of ATS timers.
1.3.6.1.4.1.318.1.1.17.3.3.2.1.6INTEGERread-writemandatory
xATSSwitchBlockMap
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.3.4
xATSSwitchBlockMapTableSize
OBJECT-TYPE
The number of blocking map entries, or how many ATS actions can be blocked.
1.3.6.1.4.1.318.1.1.17.3.4.1INTEGERread-onlymandatory
xATSSwitchBlockMapTable
OBJECT-TYPE
A list of blocking maps supported by the ATS. The number of entries is contained in the xATSSwitchBlockMapTableSize OID.
1.3.6.1.4.1.318.1.1.17.3.4.2not-accessiblemandatory
xATSSwitchBlockMapEntry
OBJECT-TYPE
An entry containing information about a specific ATS blocking map.
1.3.6.1.4.1.318.1.1.17.3.4.2.1not-accessiblemandatory
xATSSwitchBlockMapIndex
OBJECT-TYPE
Index of blocking map entries in the table.
1.3.6.1.4.1.318.1.1.17.3.4.2.1.1INTEGERread-onlymandatory
xATSSwitchBlockMapName
OBJECT-TYPE
A string describing the ATS action to be blocked.
1.3.6.1.4.1.318.1.1.17.3.4.2.1.2DisplayStringread-onlymandatory
xATSSwitchBlockMapStatus
OBJECT-TYPE
Represents the status of this blocking map entry, in bit-mapped format. A non-zero value indicates that this entry's ATS action is currently being blocked. The bit(s) set indicate which input(s) are causing the blocking (bit0, bit1, etc). bit 0 - Contact 1 bit 1 - Contact 2 bit 2 - Contact 3 bit 3 - Contact 4.
1.3.6.1.4.1.318.1.1.17.3.4.2.1.3INTEGERread-onlymandatory
xATSSwitchBlockMapSetting
OBJECT-TYPE
This setting designates the inputs that block the ATS action The mapping is specified as a bit-field, where each bit set indicates the input that blocks the ATS action associated with the entry. bit 0 - Contact 1 bit 1 - Contact 2 bit 2 - Contact 3 bit 3 - Contact 4.
1.3.6.1.4.1.318.1.1.17.3.4.2.1.4INTEGERread-writemandatory
xATSSwitchStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.3.5
xATSSwitchStatisticsTableSize
OBJECT-TYPE
The number of transfer switch statistics entries.
1.3.6.1.4.1.318.1.1.17.3.5.1INTEGERread-onlymandatory
xATSSwitchStatisticsTable
OBJECT-TYPE
A list of statistics supported by ATS. The number of entries is contained in the xATSSwitchStatisticsTableSize OID.
1.3.6.1.4.1.318.1.1.17.3.5.2not-accessiblemandatory
xATSSwitchStatisticsEntry
OBJECT-TYPE
An entry containing information about an individual ATS statistic.
1.3.6.1.4.1.318.1.1.17.3.5.2.1not-accessiblemandatory
xATSSwitchStatisticsIndex
OBJECT-TYPE
Index of ATS statistics entries in the table.
1.3.6.1.4.1.318.1.1.17.3.5.2.1.1INTEGERread-onlymandatory
xATSSwitchStatisticsName
OBJECT-TYPE
This is the name of the ATS statistic associated with this entry.
1.3.6.1.4.1.318.1.1.17.3.5.2.1.2DisplayStringread-onlymandatory
xATSSwitchStatisticsValue
OBJECT-TYPE
This is the value of the ATS statistic associated with this entry.
1.3.6.1.4.1.318.1.1.17.3.5.2.1.3DisplayStringread-onlymandatory
xATSSwitchStatisticsReset
OBJECT-TYPE
This will reset the individual ATS statistic associated with this entry.
1.3.6.1.4.1.318.1.1.17.3.5.2.1.4INTEGER {yes(1), no(2)}read-writemandatory
xATSACMonitoringPoint
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.4
xATSSource1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.4.1
xATSSource1Name
OBJECT-TYPE
String used to identify source 1.
1.3.6.1.4.1.318.1.1.17.4.1.1DisplayStringread-writemandatory
xATSSource1Position
OBJECT-TYPE
The current position of the switch at source 1.
1.3.6.1.4.1.318.1.1.17.4.1.2INTEGER {open(1), closed(2), tripped(3), unknown(4)}read-onlymandatory
xATSSource1Frequency
OBJECT-TYPE
The frequency at source 1 in tenths of Hertz. -1 if unavailable.
1.3.6.1.4.1.318.1.1.17.4.1.3INTEGERread-onlymandatory
xATSSource1Quality
OBJECT-TYPE
The current line quality of source 1.
1.3.6.1.4.1.318.1.1.17.4.1.4INTEGER {sourceGood(1), lowVoltage(2), highVoltage(3), phaseImbalance(4), freqOutOfRange(5), badRotation(6), unknown(7)}read-onlymandatory
xATSSource1Rotation
OBJECT-TYPE
The phase rotation measured at the source 1 input of the ATS. The sequence is a reference to the order in which the three phases pass the zero-crossing boundary in time.
1.3.6.1.4.1.318.1.1.17.4.1.5INTEGER {abc(1), cba(2), unknown(3)}read-onlymandatory
xATSSource1TableSize
OBJECT-TYPE
The number of input voltage entries at the source 1 input of the ATS.
1.3.6.1.4.1.318.1.1.17.4.1.6INTEGERread-onlymandatory
xATSSource1PhaseTable
OBJECT-TYPE
A list of voltage table entries for source 1. The number of entries are the phase entries. The number of entries is contained in the xATSSource1TableSize OID.
1.3.6.1.4.1.318.1.1.17.4.1.7not-accessiblemandatory
xATSSource1PhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input voltage phase at the source 1 input of the ATS.
1.3.6.1.4.1.318.1.1.17.4.1.7.1not-accessiblemandatory
xATSSource1Index
OBJECT-TYPE
Description of each phase utilized at source 1.
1.3.6.1.4.1.318.1.1.17.4.1.7.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xATSSource1VoltageLtoL
OBJECT-TYPE
Source 1 line-to-line input voltage. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.17.4.1.7.1.2INTEGERread-onlymandatory
xATSSource1VoltageLtoN
OBJECT-TYPE
Source 1 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type.
1.3.6.1.4.1.318.1.1.17.4.1.7.1.3INTEGERread-onlymandatory
xATSSource2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.4.2
xATSSource2Name
OBJECT-TYPE
String used to identify source 2.
1.3.6.1.4.1.318.1.1.17.4.2.1DisplayStringread-writemandatory
xATSSource2Position
OBJECT-TYPE
The current position of the switch at source 2.
1.3.6.1.4.1.318.1.1.17.4.2.2INTEGER {open(1), closed(2), tripped(3), unknown(4)}read-onlymandatory
xATSSource2Frequency
OBJECT-TYPE
The frequency at source 2 in tenths of Hertz. -1 if not available.
1.3.6.1.4.1.318.1.1.17.4.2.3INTEGERread-onlymandatory
xATSSource2Quality
OBJECT-TYPE
The current line quality of source 2.
1.3.6.1.4.1.318.1.1.17.4.2.4INTEGER {sourceGood(1), lowVoltage(2), highVoltage(3), phaseImbalance(4), freqOutOfRange(5), badRotation(6), unknown(7)}read-onlymandatory
xATSSource2Rotation
OBJECT-TYPE
The phase rotation measured at the source 2 input of the ATS. -1 if not available.
1.3.6.1.4.1.318.1.1.17.4.2.5INTEGER {abc(1), cba(2), unknown(3)}read-onlymandatory
xATSSource2TableSize
OBJECT-TYPE
The number of input voltage entries at the source 2 input of the ATS.
1.3.6.1.4.1.318.1.1.17.4.2.6INTEGERread-onlymandatory
xATSSource2PhaseTable
OBJECT-TYPE
A list of voltage table entries for the source 2. The number of entries are the phase entries. The number of entries is contained in the xATSSource2TableSize OID.
1.3.6.1.4.1.318.1.1.17.4.2.7not-accessiblemandatory
xATSSource2PhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input voltage phase at the source 2 input of the ATS.
1.3.6.1.4.1.318.1.1.17.4.2.7.1not-accessiblemandatory
xATSSource2Index
OBJECT-TYPE
Description of each phase utilized at the source 2.
1.3.6.1.4.1.318.1.1.17.4.2.7.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xATSSource2VoltageLtoL
OBJECT-TYPE
Source 2 line-to-line input voltage. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.17.4.2.7.1.2INTEGERread-onlymandatory
xATSSource2VoltageLtoN
OBJECT-TYPE
Source 2 line-to-neutral input voltage. Measured in tenths of Volts. -1 for a 3-wire service type.
1.3.6.1.4.1.318.1.1.17.4.2.7.1.3INTEGERread-onlymandatory
xATSSystemOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.4.3
xATSSystemOutputFrequency
OBJECT-TYPE
The system output frequency in tenths of Hertz.
1.3.6.1.4.1.318.1.1.17.4.3.1INTEGERread-onlymandatory
xATSSystemOutputTotalPower
OBJECT-TYPE
Shows the total system output power in tenths of kW.
1.3.6.1.4.1.318.1.1.17.4.3.2INTEGERread-onlymandatory
xATSSystemOutputTotalApparentPower
OBJECT-TYPE
Shows the total system output power in tenths of kVA.
1.3.6.1.4.1.318.1.1.17.4.3.3INTEGERread-onlymandatory
xATSSystemOutputTotalPowerFactor
OBJECT-TYPE
Indicates the total power factor of the system output. A value of 100 representing a unity power factor (1.00) Specified in hundredths.
1.3.6.1.4.1.318.1.1.17.4.3.4INTEGERread-onlymandatory
xATSSystemOutputFrequencyTolerance
OBJECT-TYPE
Shows the panel output frequency tolerance in +/- Hertz.
1.3.6.1.4.1.318.1.1.17.4.3.5INTEGER {freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10)}read-writemandatory
xATSSystemOutputOverVoltThreshold
OBJECT-TYPE
Threshold above which an output over voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.17.4.3.6INTEGERread-writemandatory
xATSSystemOutputUnderVoltThreshold
OBJECT-TYPE
Threshold below which an output under voltage condition will be generated. Specified as tenths of percent deviation from nominal. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.17.4.3.7INTEGERread-writemandatory
xATSSystemOutputOverCurrentThreshold
OBJECT-TYPE
Threshold above which an over current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.17.4.3.8INTEGER (0..100)read-writemandatory
xATSSystemOutputUnderCurrentThreshold
OBJECT-TYPE
Threshold below which an under current condition will be generated. Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID). A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.17.4.3.9INTEGER (0..100)read-writemandatory
xATSSystemOutputAlarmDelayThreshold
OBJECT-TYPE
Delay the generation of an output alarm. Specified in seconds.
1.3.6.1.4.1.318.1.1.17.4.3.10INTEGERread-writemandatory
xATSSystemOutputTableSize
OBJECT-TYPE
The number of system output phase entries.
1.3.6.1.4.1.318.1.1.17.4.3.11INTEGERread-onlymandatory
xATSSystemOutputPhaseTable
OBJECT-TYPE
A list of system output table entries. The number of entries is contained in the xATSSystemOutputTableSize OID.
1.3.6.1.4.1.318.1.1.17.4.3.12not-accessiblemandatory
xATSSystemOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular system output phase.
1.3.6.1.4.1.318.1.1.17.4.3.12.1not-accessiblemandatory
xATSSystemOutputPhaseIndex
OBJECT-TYPE
Description of each system output phase utilized in this device.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xATSSystemOutputVoltageLtoL
OBJECT-TYPE
Line-to-line system output voltage available at the circuit panel. Measured in tenths of Volts. -1 if not available.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.2INTEGERread-onlymandatory
xATSSystemOutputVoltageLtoN
OBJECT-TYPE
Line-to-neutral system output voltage available at the circuit panel. Measured in tenths of Volts. -1 for a 3-wire service type or if not available.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.3INTEGERread-onlymandatory
xATSSystemOutputPhaseCurrent
OBJECT-TYPE
System load current per phase. Measured in Amps. -1 if not available.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.4INTEGERread-onlymandatory
xATSSystemOutputPower
OBJECT-TYPE
System output power per phase. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.5INTEGERread-onlymandatory
xATSSystemOutputApparentPower
OBJECT-TYPE
system output power per phase. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.6INTEGERread-onlymandatory
xATSSystemOutputPowerFactor
OBJECT-TYPE
indicates the power factor of the system output per phase. A value of 100 representing a unity power factor (1.00). Measured in hundredths.
1.3.6.1.4.1.318.1.1.17.4.3.12.1.7INTEGERread-onlymandatory
xATSTesting
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.5
xATSTestingStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.5.1
xATSTestingStatusSelectTestProcess
OBJECT-TYPE
Type of tests that can be selected when no test has been scheduled. engineStartTest and systemLoadTest may be selected when no tests are running. Tests that are selected may be canceled manually.
1.3.6.1.4.1.318.1.1.17.5.1.1INTEGER {engineStartTest(1), systemLoadTest(2), generatorHoldTest(3), cancelTest(4)}read-writemandatory
xATSTestingStatusTestStatus
OBJECT-TYPE
The present system test status/state.
1.3.6.1.4.1.318.1.1.17.5.1.2INTEGER {noTestInProcess(1), testPending(2), startingEngine(3), engineWarmingUp(4), awaitingTransferToS2(5), testingWithLoad(6), awaitingRetransferToS1(7), testingWithoutLoad(8), stoppingEngine(9), holdingOnGenerator(10)}read-onlymandatory
xATSTestingStatusProfileWarmupTime
OBJECT-TYPE
The amount of time that the generator will warm up during a test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value engineWarmingUp. Specified in seconds.
1.3.6.1.4.1.318.1.1.17.5.1.3INTEGERread-writemandatory
xATSTestingStatusProfileLoadedTime
OBJECT-TYPE
The amount of time that ATS will apply the system load to the generator during a system load test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value testingWithLoad. Specified in minutes.
1.3.6.1.4.1.318.1.1.17.5.1.4INTEGERread-writemandatory
xATSTestingStatusProfileUnloadedTime
OBJECT-TYPE
The amount of time that the generator will run following the warm up portion of a start test, or the loaded portion of a load test. This is portion of the test when the xATSTestingStatusTestStatus OID returns the value testingWithoutLoad. Specified in seconds.
1.3.6.1.4.1.318.1.1.17.5.1.5INTEGERread-writemandatory
xATSTestingResults
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.5.2
xATSTestingResultsLastDateOfTest
OBJECT-TYPE
Date of the last test that was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the dd/mm/yyyy format, or 'none' if not available.
1.3.6.1.4.1.318.1.1.17.5.2.1DisplayStringread-onlymandatory
xATSTestingResultsLastResult
OBJECT-TYPE
The result of the last ATS/generator system test.
1.3.6.1.4.1.318.1.1.17.5.2.2INTEGER {noResultsAvailable(1), startTestPassed(2), loadTestPassed(3), startSignalFailure(4), failedGenNotInAuto(5), failedGenEmerStop(6), failedGenShutdown(7), failedGenDidNotStart(8), failedS2NeverGood(9), genFailedDuringWarmup(10), failureOnXferToS1(11), genFailedLoaded(12), failureOnRexferToS2(13), failedOnCooldown(14), genFailedToStop(15), failedAtsInternalFault(16), failedAtsNotInAuto(17), canceledManualTest(18), canceledScheduledTest(19)}read-onlymandatory
xATSTestingResultsTestLastTestTime
OBJECT-TYPE
Time of day at which the last test was performed, either scheduled or manual. Test results are available in the xATSTestingResultsLastResult OID. Specified in the hh:mm:ss format, or 'none' if not available.
1.3.6.1.4.1.318.1.1.17.5.2.3DisplayStringread-onlymandatory
xATSTestingResultsLastCrankDuration
OBJECT-TYPE
The time spent cranking the generator before it started during the last test. Specified in seconds, or -1 if not available.
1.3.6.1.4.1.318.1.1.17.5.2.4INTEGERread-onlymandatory
xATSTestingResultsLastWarmupDuration
OBJECT-TYPE
The time spent in the engineWarmingUp state during the last system test. Specified in seconds, or -1 if not available.
1.3.6.1.4.1.318.1.1.17.5.2.5INTEGERread-onlymandatory
xATSTestingResultsLastLoadedDuration
OBJECT-TYPE
The time spent in the testingWithLoad state during the last system test. Specified in seconds, or -1 if not available.
1.3.6.1.4.1.318.1.1.17.5.2.6INTEGERread-onlymandatory
xATSTestingResultsLastUnloadedDuration
OBJECT-TYPE
The time spent in the testingWithoutLoad state during the last system test. Specified in seconds, or -1 if not available.
1.3.6.1.4.1.318.1.1.17.5.2.7INTEGERread-onlymandatory
xATSTestingSchedule
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.5.3
xATSTestingScheduleFrequency
OBJECT-TYPE
The frequency of running scheduled tests.
1.3.6.1.4.1.318.1.1.17.5.3.1INTEGER {never(1), daily(2), weekly(3), monthly(4)}read-writemandatory
xATSTestingScheduleTestDay
OBJECT-TYPE
The desired day for the scheduled test. This object applies only when the xATSTestingScheduleFrequency OID is set to weekly or monthly. For weekly test frequency, the string is the day the test will be run. For monthly test frequency, the string indicates the day, and the instance within the month. For example, for monthly frequency: 2nd Sunday, 3rd Monday, 4th Tuesday, for weekly frequency: Sunday, Monday, Tuesday.
1.3.6.1.4.1.318.1.1.17.5.3.2DisplayStringread-writemandatory
xATSTestingScheduleTestTime
OBJECT-TYPE
The time of day that the scheduled test will occur. Specified in the format hh:mm.
1.3.6.1.4.1.318.1.1.17.5.3.3DisplayStringread-writemandatory
xATSTestingScheduleTestWithLoadInterval
OBJECT-TYPE
This setting specifies which system tests should include applying the load to the generator. The applyLoadMonthlyDetailed entry in the list will apply load once, for each month represented in the xATSTestingScheduleTestWithLoadSelectMonth OID.
1.3.6.1.4.1.318.1.1.17.5.3.4INTEGER {applyLoadEveryTest(1), neverApplyLoad(2), applyLoadMonthly(3), applyLoadMonthlyDetailed(4)}read-writemandatory
xATSTestingScheduleTestWithLoadSelectMonth
OBJECT-TYPE
The detailed selection for testing with load on a month-by-month basis. This object is applicable when the xATSTestingScheduleTestWithLoadInterval is set to applyLoadMonthlyDetailed. Otherwise this selection will be ignored. Format for this string is a comma-separated entry of months. For example: Jan,Mar,Dec. The string will return 'No Months Scheduled' if no months have been selected.
1.3.6.1.4.1.318.1.1.17.5.3.5DisplayStringread-writemandatory
xATSTestingScheduleNextTestDate
OBJECT-TYPE
The date of the next scheduled test, in the format dd-mmm-yyyy.
1.3.6.1.4.1.318.1.1.17.5.3.6DisplayStringread-onlymandatory
xATSTestingSimulatePowerFail
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.5.4
xATSTestingSimulatePowerFailTest
OBJECT-TYPE
This object executes a simulated power failure for the duration indicated. Simulation can be aborted by selecting cancelSimulation.
1.3.6.1.4.1.318.1.1.17.5.4.1INTEGER {cancelSimulation(1), fiveSecondsSimulation(2), tenSecondsSimulation(3), thirtySecondsSimulation(4), oneMinuteSimulation(5), threeMinutesSimulation(6), fiveMinutesSimulation(7), tenMinutesSimulation(8)}read-writemandatory
xATSTestingSimulatePowerFailTimeRemaining
OBJECT-TYPE
Indicates the time remaining in seconds, for a simulated power failure. a value of zero indicates that simulated power failure is not active.
1.3.6.1.4.1.318.1.1.17.5.4.2INTEGERread-onlymandatory
xATSInputContacts
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.6
xATSInputContactNumContacts
OBJECT-TYPE
The number of contacts supported by the ATS.
1.3.6.1.4.1.318.1.1.17.6.1INTEGERread-onlymandatory
xATSInputContactTableSize
OBJECT-TYPE
The number of input contact entries.
1.3.6.1.4.1.318.1.1.17.6.2INTEGERread-onlymandatory
xATSInputContactTable
OBJECT-TYPE
A list of contacts supported by the ATS. The number of entries is contained in the xATSInputContactTableSize OID.
1.3.6.1.4.1.318.1.1.17.6.3not-accessiblemandatory
xATSInputContactEntry
OBJECT-TYPE
A contact entry containing information for a given contact.
1.3.6.1.4.1.318.1.1.17.6.3.1not-accessiblemandatory
xATSInputContactNumber
OBJECT-TYPE
An index identifying the contact on the ATS.
1.3.6.1.4.1.318.1.1.17.6.3.1.1INTEGERread-onlymandatory
xATSInputContactName
OBJECT-TYPE
The description of the purpose/use of the contact.
1.3.6.1.4.1.318.1.1.17.6.3.1.2DisplayStringread-writemandatory
xATSInputContactNormalState
OBJECT-TYPE
The normal operating position of the contact.
1.3.6.1.4.1.318.1.1.17.6.3.1.3INTEGER {open(1), closed(2)}read-writemandatory
xATSInputContactCurrentState
OBJECT-TYPE
This value indicates the current state of the contact.
1.3.6.1.4.1.318.1.1.17.6.3.1.4INTEGER {open(1), closed(2)}read-onlymandatory
xATSOutputRelays
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.7
xATSOutputRelayNumRelays
OBJECT-TYPE
The number of output relays supported by the ATS.
1.3.6.1.4.1.318.1.1.17.7.1INTEGERread-onlymandatory
xATSOutputRelayTableSize
OBJECT-TYPE
The number of output relay entries.
1.3.6.1.4.1.318.1.1.17.7.2INTEGERread-onlymandatory
xATSOutputRelayTable
OBJECT-TYPE
A list of output relays supported by the ATS. The number of entries is contained in the xATSOutputRelayTableSize OID.
1.3.6.1.4.1.318.1.1.17.7.3not-accessiblemandatory
xATSOutputRelayEntry
OBJECT-TYPE
A output relay entry containing information for a given contact.
1.3.6.1.4.1.318.1.1.17.7.3.1not-accessiblemandatory
xATSOutputRelayNumber
OBJECT-TYPE
An index identifying the output relay on the ATS.
1.3.6.1.4.1.318.1.1.17.7.3.1.1INTEGERread-onlymandatory
xATSOutputRelayName
OBJECT-TYPE
The description of the purpose/use of the output relay.
1.3.6.1.4.1.318.1.1.17.7.3.1.2DisplayStringread-writemandatory
xATSOutputRelayNormalState
OBJECT-TYPE
The normal operating position of the output relay.
1.3.6.1.4.1.318.1.1.17.7.3.1.3INTEGER {open(1), closed(2)}read-writemandatory
xATSOutputRelayCurrentState
OBJECT-TYPE
This value indicates the current state of the output relay.
1.3.6.1.4.1.318.1.1.17.7.3.1.4INTEGER {open(1), closed(2)}read-onlymandatory
xATSMisc
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.17.8
generator
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18
xATSGenerator
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1
xATSGeneratorIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.1
xATSGeneratorIdentModelNumber
OBJECT-TYPE
A character string identifying the model number of the generator. This value is set at the factory.
1.3.6.1.4.1.318.1.1.18.1.1.1DisplayStringread-onlymandatory
xATSGeneratorIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the generator. This value is set at the factory.
1.3.6.1.4.1.318.1.1.18.1.1.2DisplayStringread-onlymandatory
xATSGeneratorIdentDateofManufacture
OBJECT-TYPE
A character string identifying when the generator was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.18.1.1.3DisplayStringread-onlymandatory
xATSGeneratorIdentVoltageConfiguration
OBJECT-TYPE
The voltage for which the generator's alternator is designed. Specified in Volts line-to-line.
1.3.6.1.4.1.318.1.1.18.1.1.4INTEGERread-onlymandatory
xATSGeneratorIdentMaxPowerRating
OBJECT-TYPE
The max power rating of the generator. Specified in kW.
1.3.6.1.4.1.318.1.1.18.1.1.5INTEGERread-onlymandatory
xATSGeneratorIdentAlternatorFrequency
OBJECT-TYPE
The frequency for which the generator's alternator is designed. Specified in Hertz.
1.3.6.1.4.1.318.1.1.18.1.1.6INTEGERread-onlymandatory
xATSGeneratorStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.2
xATSGeneratorStatusGeneratorName
OBJECT-TYPE
The name or label for the generator connected to the source 2 of the ATS.
1.3.6.1.4.1.318.1.1.18.1.2.1DisplayStringread-writemandatory
xATSGeneratorStatusOperational
OBJECT-TYPE
The operational status of the generator. unavailable when unrecognized status is received.
1.3.6.1.4.1.318.1.1.18.1.2.2INTEGER {nocomm(1), off(2), ready(3), starting(4), idle(5), running(6), normalStop(7), emergencyStop(8), notInAuto(9), shutdown(10), unknown(11)}read-onlymandatory
xATSGeneratorStatusModeSwitchPosition
OBJECT-TYPE
The position of the generator's auto-mode switch. In automatic mode, the generator is started and stopped via the remote start contact, which has state indicated in the xATSGeneratorStatusRemoteStart OID. In manual mode generator start/stop control is via local command only. Off prevents the generator from running.
1.3.6.1.4.1.318.1.1.18.1.2.3INTEGER {off(1), manual(2), automatic(3), unknown(4)}read-onlymandatory
xATSGeneratorStatusRemoteStart
OBJECT-TYPE
The status of the generator's remote start contact, which is provided as an output from the transfer switch to start/stop the generator when in automatic mode.
1.3.6.1.4.1.318.1.1.18.1.2.4INTEGER {stop(1), run(2), unknown(3)}read-onlymandatory
xATSGeneratorAdvStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.3
xATSGeneratorAdvStatusBatteryVoltage
OBJECT-TYPE
The voltage of the generator's starting battery. Measured in tenths of VDC, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.3.1INTEGERread-onlymandatory
xATSGeneratorAdvStatusOilPressure
OBJECT-TYPE
The generator's engine oil pressure. Measured in tenths of Psi or kPa, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.3.2INTEGERread-onlymandatory
xATSGeneratorAdvStatusCoolantTemperature
OBJECT-TYPE
Current coolant temperature in the generator. Measured in degrees Celsius or Fahrenheit, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.3.3INTEGERread-onlymandatory
xATSGeneratorAdvStatusEngineRPM
OBJECT-TYPE
Current engine speed of the generator. Measured in RPM, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.3.4INTEGERread-onlymandatory
xATSGeneratorAdvStatusOilLevel
OBJECT-TYPE
Indicates adequate oil level in the generator.
1.3.6.1.4.1.318.1.1.18.1.3.5INTEGER {ok(1), low(2), unknown(3)}read-onlymandatory
xATSGeneratorAdvStatusCoolantLevel
OBJECT-TYPE
Indicates adequate coolant level in the generator.
1.3.6.1.4.1.318.1.1.18.1.3.6INTEGER {ok(1), low(2), unknown(3)}read-onlymandatory
xATSGeneratorOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.4
xATSGeneratorOutputFrequency
OBJECT-TYPE
The output frequency of the generator. Measured in tenths of Hertz, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.1INTEGERread-onlymandatory
xATSGeneratorOutputTotalPower
OBJECT-TYPE
The total output power of the generator. Measured in tenths of tenths of kW, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.2INTEGERread-onlymandatory
xATSGeneratorOutputTotalApparentPower
OBJECT-TYPE
The total output power of the generator. Measured in tenths of kVA, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.3INTEGERread-onlymandatory
xATSGeneratorOutputTotalPowerFactor
OBJECT-TYPE
Indicates the total load power factor of the generator. A value of 100 representing a unity power factor (1.00), or -1 when if not available.
1.3.6.1.4.1.318.1.1.18.1.4.4INTEGERread-onlymandatory
xATSGeneratorOutputTableSize
OBJECT-TYPE
The number of generator output phase entries.
1.3.6.1.4.1.318.1.1.18.1.4.5INTEGERread-onlymandatory
xATSGeneratorOutputPhaseTable
OBJECT-TYPE
A list of generator output table entries. The number of entries is contained in the xATSGeneratorOutputTableSize OID.
1.3.6.1.4.1.318.1.1.18.1.4.6not-accessiblemandatory
xATSGeneratorOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular generator output phase.
1.3.6.1.4.1.318.1.1.18.1.4.6.1not-accessiblemandatory
xATSGeneratorOutputPhaseIndex
OBJECT-TYPE
Description of each generator output phase utilized in this device.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
xATSGeneratorOutputVoltageLtoL
OBJECT-TYPE
Line-to-line generator output voltage. Measured in Volts, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.2INTEGERread-onlymandatory
xATSGeneratorOutputVoltageLtoN
OBJECT-TYPE
Line-to-neutral generator output voltage. Measured in volts, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.3INTEGERread-onlymandatory
xATSGeneratorOutputPhaseCurrent
OBJECT-TYPE
Generator load current per phase. Measured in Amps, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.4INTEGERread-onlymandatory
xATSGeneratorOutputPower
OBJECT-TYPE
Generator output power per phase. Measured in tenths of kW, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.5INTEGERread-onlymandatory
xATSGeneratorOutputApparentPower
OBJECT-TYPE
Generator output power per phase. Measured in tenths of kVA, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.6INTEGERread-onlymandatory
xATSGeneratorOutputPowerFactor
OBJECT-TYPE
Indicates the load power factor of the generator output per phase. A value of 100 representing a unity power factor (1.00), or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.4.6.1.7INTEGERread-onlymandatory
xATSGeneratorSettings
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.5
xATSGeneratorSettingsVoltageAdjust
OBJECT-TYPE
The voltage adjust of the generator. Specified in volts line-to-line, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.5.1INTEGERread-onlymandatory
xATSGeneratorSettingsFrequencyAdjust
OBJECT-TYPE
The frequency adjust of the generator. Specified in tenths of Hertz.
1.3.6.1.4.1.318.1.1.18.1.5.2INTEGERread-onlymandatory
xATSGeneratorSettingsStartDelay
OBJECT-TYPE
The delay, in seconds, after the remote run signal is activated before the generator's engine will be cranked to start, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.5.3INTEGERread-onlymandatory
xATSGeneratorSettingsStopDelay
OBJECT-TYPE
The delay, in seconds, before the generator will stop after the remote run signal is deactivated, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.5.4INTEGERread-onlymandatory
xATSGeneratorSettingsCrankCycleEnable
OBJECT-TYPE
When Crank Cycle is enabled, the engine will be cranked up to the time specified by the xATSGeneratorSettingsCrankTime OID. If the generator's engine does not start, there will be a pause as specified by the xATSGeneratorSettingsCrankRestTime OID before the engine will be cranked again. This cycle is repeated as specified by the xATSGeneratorSettingsNumberCrank OID. When crank cycle is disabled, the generator's engine will be cranked continuously until it starts.
1.3.6.1.4.1.318.1.1.18.1.5.5INTEGER {disabled(1), enabled(2), unknown(3)}read-onlymandatory
xATSGeneratorSettingsCrankTime
OBJECT-TYPE
The duration of engine cranking, in seconds, when starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.5.6INTEGERread-onlymandatory
xATSGeneratorSettingsCrankRestTime
OBJECT-TYPE
The pause duration, in seconds, following an unsuccessful attempt to start the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.5.7INTEGERread-onlymandatory
xATSGeneratorSettingsNumberCrank
OBJECT-TYPE
The number of failed crank attempts before giving up on starting the generator. Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.5.8INTEGERread-onlymandatory
xATSGeneratorSettingsMetricUnit
OBJECT-TYPE
Specifies the use of metric units in generator related OIDs, as well as on all other interfaces including the generator's local interface.
1.3.6.1.4.1.318.1.1.18.1.5.9INTEGER {disabled(1), enabled(2)}read-writemandatory
xATSGeneratorService
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.6
xATSGeneratorServiceTotalRunHoursLifetime
OBJECT-TYPE
Total time that the generator engine has been run, over the life of the generator. Measured in hours. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.6.1INTEGERread-onlymandatory
xATSGeneratorServiceEngineStartsLifetime
OBJECT-TYPE
Number of engine starts over the life of the generator. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.6.2INTEGERread-onlymandatory
xATSGeneratorServiceTotalkWhLifetime
OBJECT-TYPE
Total kWh of operation over the life of the generator. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.6.3INTEGERread-onlymandatory
xATSGeneratorServiceTotalRunHoursSinceMaintenance
OBJECT-TYPE
Total time that the generator engine has been run, since last service maintenance. Measured in tenths of hours. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.6.4INTEGERread-onlymandatory
xATSGeneratorServiceEngineStartsSinceMaintenance
OBJECT-TYPE
Number of engine starts since last service maintenance. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.6.5INTEGERread-onlymandatory
xATSGeneratorServiceTotalkWhMaintenance
OBJECT-TYPE
Total kWh of operation since last service maintenance. -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.6.6INTEGERread-onlymandatory
xATSGeneratorServiceResetRecord
OBJECT-TYPE
Resets the engine start counter, engine run-hours, and kWh values that have accumulated in the generator since last maintenance. Also, the last service date will be reset to the current system date, and any service alarms will be cleared.
1.3.6.1.4.1.318.1.1.18.1.6.7INTEGER {yes(1), no(2)}read-writemandatory
xATSGeneratorServiceRecordResetDate
OBJECT-TYPE
Date at which the generator's service record was reset, in dd-mmm-yyyy format.
1.3.6.1.4.1.318.1.1.18.1.6.8DisplayStringread-onlymandatory
xATSGeneratorServiceNextServiceDate
OBJECT-TYPE
Date at which the next generator service is due in dd-mmm-yyyy format. Based on the xATSGeneratorServiceCalendarIntervalThreshold OID or '' if the calendar-based threshold is set to off.
1.3.6.1.4.1.318.1.1.18.1.6.9DisplayStringread-onlymandatory
xATSGeneratorServiceRunHoursUntilServiceDate
OBJECT-TYPE
Run hours until the next generator service is due, in hours. Based on the xATSGeneratorServiceRunHoursThreshold OID or -1 if the run hour-based threshold is set to off.
1.3.6.1.4.1.318.1.1.18.1.6.10INTEGERread-onlymandatory
xATSGeneratorServiceRunHoursThreshold
OBJECT-TYPE
Run hour-based service interval. When the run-hours since service surpasses this threshold, generator service is due.
1.3.6.1.4.1.318.1.1.18.1.6.11INTEGER {disabled(1), runThreshold100Hours(2), runThreshold150Hours(3), runThreshold200Hours(4), runThreshold250Hours(5), runThreshold300Hours(6), runThreshold400Hours(7), runThreshold500Hours(8)}read-writemandatory
xATSGeneratorServiceCalendarIntervalThreshold
OBJECT-TYPE
Calendar-based service interval. When the next service date, as indicated by the xATSGeneratorServiceNextServiceDate OID is in the past, generator is due for service.
1.3.6.1.4.1.318.1.1.18.1.6.12INTEGER {disabled(1), interval1month(2), interval2month(3), interval3month(4), interval6month(5), intervalyearly(6)}read-writemandatory
xATSGeneratorFuelSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.18.1.7
xATSGeneratorFuelSystemType
OBJECT-TYPE
The type of fuel used by the generator.
1.3.6.1.4.1.318.1.1.18.1.7.1INTEGER {diesel(1), propane(2), naturalGas(3), unknown(4)}read-onlymandatory
xATSGeneratorFuelSystemTankSize
OBJECT-TYPE
Size of the generator's fuel tank. Specified in gallons or liters, based on the value of the xATSGeneratorSettingsMetricUnit OID, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.7.2INTEGERread-onlymandatory
xATSGeneratorFuelSystemFuelLevel
OBJECT-TYPE
Fuel remaining in the generator tank. Measured in percent of tank fill, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.7.3INTEGERread-onlymandatory
xATSGeneratorFuelSystemRuntimePower
OBJECT-TYPE
The power value used in the runtime remaining calculation. Measured in tenths of kW, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.7.4INTEGERread-onlymandatory
xATSGeneratorFuelSystemEstimatedRunTime
OBJECT-TYPE
An estimate of available runtime for the generator, based on available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID and kW load as specified in the xATSGeneratorFuelSystemRuntimePower OID. Measured in tenths of hours, or -1 if not available.
1.3.6.1.4.1.318.1.1.18.1.7.5INTEGERread-onlymandatory
xATSGeneratorFuelSystemLowRunTimeThreshold
OBJECT-TYPE
Threshold below which a low runtime alarm will exist.
1.3.6.1.4.1.318.1.1.18.1.7.6INTEGER {disabled(1), oneHour(2), twoHours(3), threeHours(4), fourHours(5), fiveHours(6), sixHours(7), twelveHours(8), oneDay(9), twoDays(10), threeDays(11), fourDays(12), fiveDays(13), sixDays(14), sevenDays(15)}read-writemandatory
xATSGeneratorFuelSystemVeryLowRunTimeThreshold
OBJECT-TYPE
Threshold below which a very low runtime alarm will exist.
1.3.6.1.4.1.318.1.1.18.1.7.7INTEGER {disabled(1), oneHour(2), twoHours(3), threeHours(4), fourHours(5), fiveHours(6), sixHours(7), twelveHours(8), oneDay(9), twoDays(10), threeDays(11), fourDays(12), fiveDays(13), sixDays(14), sevenDays(15)}read-writemandatory
xATSGeneratorFuelSystemLowFuelLevelThreshold
OBJECT-TYPE
Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill.
1.3.6.1.4.1.318.1.1.18.1.7.8INTEGER (0..100)read-writemandatory
xATSGeneratorFuelSystemVeryLowFuelLevelThreshold
OBJECT-TYPE
Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled. Specified as percent of tank fill.
1.3.6.1.4.1.318.1.1.18.1.7.9INTEGER (0..100)read-writemandatory
consolePortServer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19
cpsAP930x
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1
cpsAP930xSys
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.1
apCPSpname
OBJECT-TYPE
The product's name.
1.3.6.1.4.1.318.1.1.19.1.1.1DisplayStringread-onlymandatory
apCPSversion
OBJECT-TYPE
The firmware's version.
1.3.6.1.4.1.318.1.1.19.1.1.2DisplayStringread-onlymandatory
apCPSPower
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.1.3
apCPSPwNum
OBJECT-TYPE
The number of the power supplies.
1.3.6.1.4.1.318.1.1.19.1.1.3.1Integer32read-onlymandatory
apCPSPw1
OBJECT-TYPE
State of the first power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF.
1.3.6.1.4.1.318.1.1.19.1.1.3.2INTEGERread-onlymandatory
apCPSPw2
OBJECT-TYPE
State of the second power supply. 0 will indicate not installed, 1 will indicate power ON, 2 will indicate power OFF.
1.3.6.1.4.1.318.1.1.19.1.1.3.3INTEGERread-onlymandatory
apCPSPcmcia
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.1.4
apCPSNPcmcia
OBJECT-TYPE
Number of PCMCIA cards available.
1.3.6.1.4.1.318.1.1.19.1.1.4.1Integer32read-onlymandatory
cpsCardIdentTable
OBJECT-TYPE
A table of PCMCIA card identifications.
1.3.6.1.4.1.318.1.1.19.1.1.4.2not-accessiblemandatory
cpsCardIdentEntry
OBJECT-TYPE
Identification information for a PCMCIA card.
1.3.6.1.4.1.318.1.1.19.1.1.4.2.1not-accessiblemandatory
cpsCardIdentIndex
OBJECT-TYPE
Number to identify the socket Card.
1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.1Integer32read-onlymandatory
cpsCardIdentProd
OBJECT-TYPE
Product identification string.
1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.2DisplayStringread-onlymandatory
cpsCardIdentMan
OBJECT-TYPE
Manufacturer ID code.
1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.3DisplayStringread-onlymandatory
cpsCardIdentFunc
OBJECT-TYPE
Function ID code.
1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.4DisplayStringread-onlymandatory
cpsCardIdentPCI
OBJECT-TYPE
PCI ID
1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.5DisplayStringread-onlymandatory
cpsCardConfTable
OBJECT-TYPE
A table of socket configuration information.
1.3.6.1.4.1.318.1.1.19.1.1.4.3not-accessiblemandatory
cpsCardConfEntry
OBJECT-TYPE
Configuration information for a socket.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1not-accessiblemandatory
cpsCardConfIndex
OBJECT-TYPE
Number to identify the socket PCMCIA.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.1Integer32read-onlymandatory
cpsCardConfPower
OBJECT-TYPE
Power Settings.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.2DisplayStringread-onlymandatory
cpsCardConfType
OBJECT-TYPE
Interface Type.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.3DisplayStringread-onlymandatory
cpsCardConfInter
OBJECT-TYPE
Interrupt number.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.4DisplayStringread-onlymandatory
cpsCardConfFunc
OBJECT-TYPE
Function.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.5DisplayStringread-onlymandatory
cpsCardConfCardv
OBJECT-TYPE
Card values.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.6DisplayStringread-onlymandatory
cpsCardConfPort1
OBJECT-TYPE
I/O Port 1.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.7DisplayStringread-onlymandatory
cpsCardConfPort2
OBJECT-TYPE
I/O Port 2.
1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.8DisplayStringread-onlymandatory
cpsCardStatusTable
OBJECT-TYPE
A table of current socket status information.
1.3.6.1.4.1.318.1.1.19.1.1.4.4not-accessiblemandatory
cpsCardStatusEntry
OBJECT-TYPE
Current status information for a socket.
1.3.6.1.4.1.318.1.1.19.1.1.4.4.1not-accessiblemandatory
cpsCardStatusIndex
OBJECT-TYPE
Number to identify the socket PCMCIA.
1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.1Integer32 (0..2)read-onlymandatory
cpsCardStatusCard
OBJECT-TYPE
Current Card State.
1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.2DisplayStringread-onlymandatory
cpsCardStatusFunc
OBJECT-TYPE
Current Function.
1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.3DisplayStringread-onlymandatory
apCPSFlashSize
OBJECT-TYPE
Total amount of flash memory in Mbytes.
1.3.6.1.4.1.318.1.1.19.1.1.5Integer32read-onlymandatory
apCPSRAMSize
OBJECT-TYPE
Total amount of RAM in Mbytes.
1.3.6.1.4.1.318.1.1.19.1.1.6Integer32read-onlymandatory
apCPSCPUfreq
OBJECT-TYPE
CPU clock in MHz.
1.3.6.1.4.1.318.1.1.19.1.1.7Integer32read-onlymandatory
apCPSDevId
OBJECT-TYPE
The product's identifier.
1.3.6.1.4.1.318.1.1.19.1.1.8DisplayStringread-onlymandatory
cpsAP930xConf
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2
cpsHostName
OBJECT-TYPE
The Host Name.
1.3.6.1.4.1.318.1.1.19.1.2.1DisplayString (SIZE(0..40))read-writemandatory
cpsConsoleBanner
OBJECT-TYPE
The console banner.
1.3.6.1.4.1.318.1.1.19.1.2.2DisplayString (SIZE(0..255))read-writemandatory
cpsMotd
OBJECT-TYPE
The motd message.
1.3.6.1.4.1.318.1.1.19.1.2.3DisplayString (SIZE(0..255))read-writemandatory
cpsEthItf
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2.4
cpsEthDhcpc
OBJECT-TYPE
0 will indicate DHCP inactive, 1 will indicate DHCP active, 2 will indicate DHCP active and the last parameter is saved.
1.3.6.1.4.1.318.1.1.19.1.2.4.1INTEGERread-writemandatory
cpsEthIPaddr
OBJECT-TYPE
This is the IP address of the Ethernet Interface.
1.3.6.1.4.1.318.1.1.19.1.2.4.2IpAddressread-writemandatory
cpsEthIPmask
OBJECT-TYPE
The mask for the Ethernet network.
1.3.6.1.4.1.318.1.1.19.1.2.4.3IpAddressread-writemandatory
cpsEthMTU
OBJECT-TYPE
The Maximum Transmission Unit size, which determines whether packets should be broken up.
1.3.6.1.4.1.318.1.1.19.1.2.4.4Integer32read-writemandatory
cpsEthIPaddr2
OBJECT-TYPE
The Ethernet secondary IP address.
1.3.6.1.4.1.318.1.1.19.1.2.4.5IpAddressread-writemandatory
cpsEthIPmask2
OBJECT-TYPE
The Ethernet secondary IP mask.
1.3.6.1.4.1.318.1.1.19.1.2.4.6IpAddressread-writemandatory
cpsNameService
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2.5
cpsResolverOrder
OBJECT-TYPE
Specifies how host lookups are to be performed. Valid values : empty, 'hosts', 'bind', 'hosts, bind', 'bind, hosts'
1.3.6.1.4.1.318.1.1.19.1.2.5.1DisplayString (SIZE(0..15))read-writemandatory
cpsMultipleIP
OBJECT-TYPE
Valid values are ON or OFF. If set to ON, the resolve library will return all valid addresses for a host that appears in the /etc/hosts file, instead of only the first.
1.3.6.1.4.1.318.1.1.19.1.2.5.2DisplayString (SIZE(0..3))read-writemandatory
cpsDNSserv
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2.5.3
cpsDNSpriserv
OBJECT-TYPE
Internet Address (in dot notation) of primary name server that the resolver should query.
1.3.6.1.4.1.318.1.1.19.1.2.5.3.1IpAddressread-writemandatory
cpsDNSsecserv
OBJECT-TYPE
Internet Address (in dot notation) of secondary name server that the resolver should query.
1.3.6.1.4.1.318.1.1.19.1.2.5.3.2IpAddressread-writemandatory
cpsDNSdomain
OBJECT-TYPE
Local domain name.
1.3.6.1.4.1.318.1.1.19.1.2.5.3.3DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortConf
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2.6
cpsSerialGlobal
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2.6.1
cpsSerialInclude
OBJECT-TYPE
File used in centralized management.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.1DisplayString (SIZE(0..40))read-writemandatory
cpsSerialNFS
OBJECT-TYPE
Remote Network File System where data buffering will be written instead of the default directory '/var/run/DB'.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.2DisplayString (SIZE(0..50))read-writemandatory
cpsSerialLockDir
OBJECT-TYPE
The lock directory.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.3DisplayString (SIZE(0..50))read-writemandatory
cpsSerialRlogin
OBJECT-TYPE
Location of the rlogin binary that accepts the -i flag.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.4DisplayString (SIZE(0..50))read-writemandatory
cpsSerialPppd
OBJECT-TYPE
Location of the pppd binary.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.5DisplayString (SIZE(0..50))read-writemandatory
cpsSerialTelnet
OBJECT-TYPE
Location of the telnet application.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.6DisplayString (SIZE(0..50))read-writemandatory
cpsSerialSsh
OBJECT-TYPE
Location of the ssh application.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.7DisplayString (SIZE(0..50))read-writemandatory
cpsSerialLocalLogins
OBJECT-TYPE
This parameter is only necessary when authentication is being performed for a port. This is useful if the Radius authentication server is down. 0 indicates OFF, 1 indicates ON.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.8INTEGERread-writemandatory
cpsSerialFacility
OBJECT-TYPE
This value (0-7) is the Local facility sent to the syslog daemon.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.9Integer32read-writemandatory
cpsSerialDBFacility
OBJECT-TYPE
This value (0-7) is the Local facility sent to the syslog daemon.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.10Integer32read-writemandatory
cpsSerialGroupTable
OBJECT-TYPE
1.3.6.1.4.1.318.1.1.19.1.2.6.1.11not-accessiblemandatory
cpsSerialGroupEntry
OBJECT-TYPE
1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1not-accessiblemandatory
cpsSerialGroupIndex
OBJECT-TYPE
Number to identify the group.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.1INTEGERread-onlymandatory
cpsSerialGroupName
OBJECT-TYPE
The group name.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.2DisplayString (SIZE(0..20))read-writemandatory
cpsSerialGroupUsers
OBJECT-TYPE
The user's names.
1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.3DisplayString (SIZE(0..80))read-writemandatory
cpsSerialSpec
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.2.6.2
cpsSerialPortTable
OBJECT-TYPE
This is the specific configuration per serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1not-accessiblemandatory
cpsSerialPortEntry
OBJECT-TYPE
One particular serial port configuration.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1not-accessiblemandatory
cpsSerialPortNumber
OBJECT-TYPE
Number to identify the serial port. Value 0 is ALL.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.1INTEGERread-onlymandatory
cpsSerialPortTty
OBJECT-TYPE
The device name for the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.2DisplayString (SIZE(0..25))read-writemandatory
cpsSerialPortName
OBJECT-TYPE
Alias name given to the server connected to the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.3DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortSpeed
OBJECT-TYPE
The speed of the serial port. Supported values are: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400, and 460800
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.4Integer32read-writemandatory
cpsSerialPortDataSize
OBJECT-TYPE
The data size for the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.5Integer32 (4..8)read-writemandatory
cpsSerialPortStopBits
OBJECT-TYPE
The number of stop bits for the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.6Integer32 (0..2)read-writemandatory
cpsSerialPortParity
OBJECT-TYPE
The parity for the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.7DisplayString (SIZE(0..5))read-writemandatory
cpsSerialPortFlowCtrl
OBJECT-TYPE
The flow control for the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.8DisplayString (SIZE(0..5))read-writemandatory
cpsSerialPortDTRdelay
OBJECT-TYPE
This specifies how long (in milliseconds) a DTR signal will be turned off before it is turned on again.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.9Integer32read-writemandatory
cpsSerialPortDCDCtrl
OBJECT-TYPE
DCD signal controls the connection request. 0 will indicate nocontrol, 1 will indicate control.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.10INTEGERread-writemandatory
cpsSerialPortLogUtmp
OBJECT-TYPE
Update the login records in /var/run/utmp file. 0 will indicate inactive, 1 will indicate active.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.11INTEGERread-writemandatory
cpsSerialPortLogWtmp
OBJECT-TYPE
Update the login records in /var/run/wtmp file. 0 will indicate inactive, 1 will indicate active.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.12INTEGERread-writemandatory
cpsSerialPortLogform
OBJECT-TYPE
This is the format to write the login record.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.13DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortAuthtype
OBJECT-TYPE
Authentication type.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.14DisplayString (SIZE(0..25))read-writemandatory
cpsSerialPortAuthSrv1
OBJECT-TYPE
IP address of the primary authentication server.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.15IpAddressread-writemandatory
cpsSerialPortAccSrv1
OBJECT-TYPE
IP address of the primary accounting server.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.16IpAddressread-writemandatory
cpsSerialPortAuthTmo
OBJECT-TYPE
This is the timeout (in seconds) for the authentication query to be answered.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.17Integer32read-writemandatory
cpsSerialPortAuthRetr
OBJECT-TYPE
This defines the number of times each server is tried before another is contacted.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.18Integer32read-writemandatory
cpsSerialPortAuthSrv2
OBJECT-TYPE
IP address of the secondary authentication server.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.19IpAddressread-writemandatory
cpsSerialPortAccSrv2
OBJECT-TYPE
IP address of the secondary accounting server.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.20IpAddressread-writemandatory
cpsSerialPortAuthSecret
OBJECT-TYPE
This is the shared secret with authentication servers.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.21DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortAuthRadP
OBJECT-TYPE
Radius state. 0 will indicate inactive, 1 will indicate active.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.22INTEGERread-writemandatory
cpsSerialPortAuthAcc
OBJECT-TYPE
Access restriction.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.23DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortProtocol
OBJECT-TYPE
Defines the serial port's protocol.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.24DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortRemoteIP
OBJECT-TYPE
This is the default IP address of the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.25DisplayString (SIZE(0..20))read-writemandatory
cpsSerialPortSocketPort
OBJECT-TYPE
This defines an alternative labeling system for the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.26DisplayString (SIZE(0..10))read-writemandatory
cpsSerialPortRemHost
OBJECT-TYPE
The IP address of the host to which the serial port will connect.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.27IpAddressread-writemandatory
cpsSerialPortBanner
OBJECT-TYPE
This defines the banner.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.28DisplayString (SIZE(0..250))read-writemandatory
cpsSerialPortPrompt
OBJECT-TYPE
This defines the login prompt to the serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.29DisplayString (SIZE(0..250))read-writemandatory
cpsSerialPortTermType
OBJECT-TYPE
This defines the terminal type.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.30DisplayString (SIZE(0..20))read-writemandatory
cpsSerialPortAutomUsr
OBJECT-TYPE
This defines the automatic user.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.31DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortNetMask
OBJECT-TYPE
The network mask used in dial in connection.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.32IpAddressread-writemandatory
cpsSerialPortPppMtu
OBJECT-TYPE
The PPP MTU - dial in connection.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.33Integer32read-writemandatory
cpsSerialPortPppMru
OBJECT-TYPE
The PPP MRU - dial in connection.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.34Integer32read-writemandatory
cpsSerialPortPppOptions
OBJECT-TYPE
The PPP options when the PPP session is autodetected.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.35DisplayStringread-writemandatory
cpsSerialPortPppFoption
OBJECT-TYPE
The PPP forced options when the user has already been authenticated.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.36DisplayStringread-writemandatory
cpsSerialPortModemChat
OBJECT-TYPE
The initchat send to modem connected.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.37DisplayStringread-writemandatory
cpsSerialPortSttyCmd
OBJECT-TYPE
The tty settings after socket connection is established.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.38DisplayString (SIZE(0..180))read-writemandatory
cpsSerialPortSockTx
OBJECT-TYPE
Defines the delay (in milliseconds) before transmission to the Ethernet of data received through a serial port.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.39Integer32read-writemandatory
cpsSerialPortSockPoll
OBJECT-TYPE
Keep-alive timer (milliseconds) for the TCP connection.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.40Integer32read-writemandatory
cpsSerialPortSockIdle
OBJECT-TYPE
The idle timeout in seconds.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.41Integer32read-writemandatory
cpsSerialPortDBsize
OBJECT-TYPE
Maximum size of the data buffering file.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.42Integer32read-writemandatory
cpsSerialPortDBtime
OBJECT-TYPE
Timestamp in data buffering. 0 will indicate inactive, 1 will indicate active.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.43INTEGERread-writemandatory
cpsSerialPortDBmode
OBJECT-TYPE
Data buffering mode : circ or line.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.44DisplayString (SIZE(0..5))read-writemandatory
cpsSerialPortDBsyslog
OBJECT-TYPE
Size of the data buffer sent to syslog.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.45Integer32read-writemandatory
cpsSerialPortDBmenu
OBJECT-TYPE
Menu type for data buffering. 0 will indicate display Menu, 1 will indicate inactive, 2 will indicate DB, 3 will indicate Parc.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.46INTEGERread-writemandatory
cpsSerialPortDBalarm
OBJECT-TYPE
Alarm generation status. 0 will indicate inactive, 1 will indicate active.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.47INTEGERread-writemandatory
cpsSerialPortSSHbreak
OBJECT-TYPE
Break sequence - ssh session.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.48DisplayString (SIZE(0..16))read-writemandatory
cpsSerialPortSniffSess
OBJECT-TYPE
Sniff session type.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.49DisplayString (SIZE(0..5))read-writemandatory
cpsSerialPortSniffAdm
OBJECT-TYPE
List of admin users allowed to sniff session.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.50DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortSniffEsc
OBJECT-TYPE
Escape sequence used in sniff session.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.51DisplayString (SIZE(0..6))read-writemandatory
cpsSerialPortSniffMsess
OBJECT-TYPE
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.52DisplayString (SIZE(0..20))read-writemandatory
cpsSerialPortTelnetMode
OBJECT-TYPE
Mode negotiated by client telnet with the server. 0 will indicate text, 1 will indicate binary.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.53INTEGERread-writemandatory
cpsSerialPortSysBufSess
OBJECT-TYPE
Syslog Buffering at all times. 0 will indicate yes, 1 will indicate no.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.54INTEGERread-writemandatory
cpsSerialPortLFSuppress
OBJECT-TYPE
LF suppression in socket_server session. 0 will indicate inactive, 1 will indicate active.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.55INTEGERread-writemandatory
cpsSerialPortAutoInput
OBJECT-TYPE
Input string used for auto answer.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.56DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortAutoOutput
OBJECT-TYPE
Output string used for auto answer.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.57DisplayString (SIZE(0..40))read-writemandatory
cpsSerialPortBreakInterval
OBJECT-TYPE
The break interval in milliseconds.
1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.58Integer32read-writemandatory
cpsAP930xInfo
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.3
cpsInfoSerialPortTable
OBJECT-TYPE
This is the information of the specific serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1not-accessiblemandatory
cpsInfoSerialPortEntry
OBJECT-TYPE
One particular serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1not-accessiblemandatory
cpsInfoSerialPortNumber
OBJECT-TYPE
Number to identify the serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.1INTEGERread-onlymandatory
cpsInfoSerialPortTty
OBJECT-TYPE
The device name for the serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.2DisplayStringread-onlymandatory
cpsInfoSerialPortName
OBJECT-TYPE
Alias name given to the server connected to the serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.3DisplayStringread-onlymandatory
cpsInfoSerialPortSpeed
OBJECT-TYPE
The speed for serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.4Integer32read-onlymandatory
cpsInfoSerialPortTxBytes
OBJECT-TYPE
The number of transmitted bytes by the serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.5Integer32read-onlymandatory
cpsInfoSerialPortRXBytes
OBJECT-TYPE
The number of received bytes by the serial port.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.6Integer32read-onlymandatory
cpsInfoSerialPortErrFrame
OBJECT-TYPE
The number of frame errors.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.7Integer32read-onlymandatory
cpsInfoSerialPortErrParity
OBJECT-TYPE
The number of parity errors.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.8Integer32read-onlymandatory
cpsInfoSerialPortErrBreaks
OBJECT-TYPE
The number of breaks errors.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.9Integer32read-onlymandatory
cpsInfoSerialPortErrOverrun
OBJECT-TYPE
The number of overrun errors.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.10Integer32read-onlymandatory
cpsInfoSerialPortSigDTR
OBJECT-TYPE
The state of the DTR signal. 0 will indicate down, 1 will indicate up.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.11INTEGERread-onlymandatory
cpsInfoSerialPortSigCD
OBJECT-TYPE
The state of the DCD signal. 0 will indicate down, 1 will indicate up.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.12INTEGERread-onlymandatory
cpsInfoSerialPortSigDSR
OBJECT-TYPE
The state of the DSR signal. 0 will indicate down, 1 will indicate up.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.13INTEGERread-onlymandatory
cpsInfoSerialPortSigRTS
OBJECT-TYPE
The state of the RTS signal. 0 will indicate down, 1 will indicate up.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.14INTEGERread-onlymandatory
cpsInfoSerialPortSigCTS
OBJECT-TYPE
The state of the CTS signal. 0 will indicate down, 1 will indicate up.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.15INTEGERread-onlymandatory
cpsInfoSerialPortSigRI
OBJECT-TYPE
The state of the RI signal. 0 will indicate down, 1 will indicate up.
1.3.6.1.4.1.318.1.1.19.1.3.1.1.16INTEGERread-onlymandatory
cpsAP930xAdm
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.19.1.4
apCPSSave
OBJECT-TYPE
Exec saveconf command. 0 will indicate don't save, 1 will indicate save.
1.3.6.1.4.1.318.1.1.19.1.4.1INTEGERread-writemandatory
apCPSSerialHUP
OBJECT-TYPE
Exec signal_ras hup command. 0 will indicate no restart, 1 will indicate restart.
1.3.6.1.4.1.318.1.1.19.1.4.2INTEGERread-writemandatory
accessControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20
accessPX
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1
accessPXIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.1
accessPXIdentAlarmStatus
OBJECT-TYPE
Access PX alarm status 1 = Normal 2 = Warning 3 = Critical.
1.3.6.1.4.1.318.1.1.20.1.1.1INTEGERread-onlymandatory
accessPXIdentProductNumber
OBJECT-TYPE
The product number of the Access PX.
1.3.6.1.4.1.318.1.1.20.1.1.2DisplayStringread-onlymandatory
accessPXIdentHardwareRev
OBJECT-TYPE
The hardware revision number of the Access PX.
1.3.6.1.4.1.318.1.1.20.1.1.3DisplayStringread-onlymandatory
accessPXIdentDateOfManufacture
OBJECT-TYPE
The date of manufacture of the Access PX.
1.3.6.1.4.1.318.1.1.20.1.1.4DisplayStringread-onlymandatory
accessPXIdentSerialNumber
OBJECT-TYPE
The serial number of the Access PX.
1.3.6.1.4.1.318.1.1.20.1.1.5DisplayStringread-onlymandatory
accessPXConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.2
accessPXConfigCardReaderEnableDisableAction
OBJECT-TYPE
Action to disable/enable the card reader.
1.3.6.1.4.1.318.1.1.20.1.2.1INTEGER {disabled(1), enable(2)}read-writemandatory
accessPXConfigAutoRelockTime
OBJECT-TYPE
Time (10 - 60) in seconds when the door will automatically relock after it has been unlocked and the handle has not been opened.
1.3.6.1.4.1.318.1.1.20.1.2.2INTEGERread-writemandatory
accessPXConfigCardFormat
OBJECT-TYPE
Indicates and controls the various card format.
1.3.6.1.4.1.318.1.1.20.1.2.3INTEGER {hidStd26(1), hid37Bit(2), hid37BitWithFacility(3), hidCorp1000(4), mifareclassic4b(5), mifareclassic7b(6), mifaredesfire(7), mifareplus(8), iCLASS8b(9)}read-writemandatory
accessPXConfigFront
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.3
accessPXConfigFrontDoorLockControl
OBJECT-TYPE
Control action (unlock, lock) for the front door. Setting this OID will unlock or lock the front door. Getting this OID will respond with the current state of the front door lock which could be 1 = unlocked, 2 = locked, 3 = not installed, 4 = disconnected.
1.3.6.1.4.1.318.1.1.20.1.3.1INTEGER {unlock(1), lock(2), notInstalledReadOnly(3), disconnectedReadOnly(4)}read-writemandatory
accessPXConfigFrontDoorMaxOpenTime
OBJECT-TYPE
Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition.
1.3.6.1.4.1.318.1.1.20.1.3.2INTEGERread-writemandatory
accessPXStatusFront
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.4
accessPXStatusFrontDoorLock
OBJECT-TYPE
Present state of the front door lock: unlocked, locked, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.4.1INTEGER {unlocked(1), locked(2), notInstalled(3), disconnected(4)}read-onlymandatory
accessPXStatusFrontDoor
OBJECT-TYPE
Present state of the front door: open, closed, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.4.2INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)}read-onlymandatory
accessPXStatusFrontDoorHandle
OBJECT-TYPE
Present state of the front door handle: open, closed, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.4.3INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)}read-onlymandatory
accessPXStatusFrontDoorMaxOpenTime
OBJECT-TYPE
Time in minutes, (1 - 120), that the front door can be allowed to remain open without generating an alarm condition.
1.3.6.1.4.1.318.1.1.20.1.4.4INTEGERread-onlymandatory
accessPXStatusFrontDoorAlarmStatus
OBJECT-TYPE
Front door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Front door not installed.
1.3.6.1.4.1.318.1.1.20.1.4.5INTEGERread-onlymandatory
accessPXConfigRear
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.5
accessPXConfigRearDoorLockControl
OBJECT-TYPE
Control action (unlock, lock) for the rear door. Setting this OID will unlock or lock the rear door. Getting this OID will respond with the current state of the rear door lock which could be 1 = unlocked, 2 = locked, 3 = not installed, 4 = disconnected.
1.3.6.1.4.1.318.1.1.20.1.5.1INTEGER {unlock(1), lock(2), notInstalledReadOnly(3), disconnectedReadOnly(4)}read-writemandatory
accessPXConfigRearDoorMaxOpenTime
OBJECT-TYPE
Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition.
1.3.6.1.4.1.318.1.1.20.1.5.2INTEGERread-writemandatory
accessPXStatusRear
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.6
accessPXStatusRearDoorLock
OBJECT-TYPE
Present state of the rear door lock: unlocked, locked, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.6.1INTEGER {unlocked(1), locked(2), notInstalled(3), disconnected(4)}read-onlymandatory
accessPXStatusRearDoor
OBJECT-TYPE
Present state of the rear door: open, closed, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.6.2INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)}read-onlymandatory
accessPXStatusRearDoorHandle
OBJECT-TYPE
Present state of the rear door handle: open, closed, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.6.3INTEGER {open(1), closed(2), notInstalled(3), disconnected(4)}read-onlymandatory
accessPXStatusRearDoorMaxOpenTime
OBJECT-TYPE
Time in minutes, (1 - 120), that the rear door can be allowed to remain open without generating an alarm condition.
1.3.6.1.4.1.318.1.1.20.1.6.4INTEGERread-onlymandatory
accessPXStatusRearDoorAlarmStatus
OBJECT-TYPE
Rear door alarm status 1 = Normal 2 = Warning 3 = Critical 4 = Rear door not installed.
1.3.6.1.4.1.318.1.1.20.1.6.5INTEGERread-onlymandatory
accessPXConfigBeacon
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.7
accessPXConfigBeaconName
OBJECT-TYPE
A descriptive name for the Beacon.
1.3.6.1.4.1.318.1.1.20.1.7.1DisplayStringread-writemandatory
accessPXConfigBeaconLocation
OBJECT-TYPE
A descriptive name for the location of the Beacon.
1.3.6.1.4.1.318.1.1.20.1.7.2DisplayStringread-writemandatory
accessPXConfigBeaconAction
OBJECT-TYPE
Control action (turnOff, turnOn) for the beacon. Setting this OID will turn the beacon off or on. Getting this OID will respond with the current state which could be 1 = off, 2 = on, 3 = not installed, 4 = disconnected.
1.3.6.1.4.1.318.1.1.20.1.7.3INTEGER {turnOff(1), turnOn(2), notInstalledReadOnly(3), disconnectedReadOnly(4)}read-writemandatory
accessPXStatusBeacon
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.20.1.8
accessPXStatusBeaconName
OBJECT-TYPE
The name of the beacon.
1.3.6.1.4.1.318.1.1.20.1.8.1DisplayStringread-onlymandatory
accessPXStatusBeaconLocation
OBJECT-TYPE
The name of the location of the beacon.
1.3.6.1.4.1.318.1.1.20.1.8.2DisplayStringread-onlymandatory
accessPXStatusBeaconCurrentState
OBJECT-TYPE
The current state of the beacon: off, on, not installed, or disconnected.
1.3.6.1.4.1.318.1.1.20.1.8.3INTEGER {off(1), on(2), notInstalled(3), disconnected(4)}read-onlymandatory
apcLocalDisplay
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.21
apcLocalDisplayIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.21.1
apcLocalDisplayIdentDisplayType
OBJECT-TYPE
Numeric value used to identify the type of display in use.
1.3.6.1.4.1.318.1.1.21.1.1INTEGER {noDisplayFound(1), powerviewRM(2), powerviewWW(3)}read-onlymandatory
apcLocalDisplayIdentModelNumber
OBJECT-TYPE
The model number of the local display.
1.3.6.1.4.1.318.1.1.21.1.2DisplayStringread-onlymandatory
apcLocalDisplayIdentFirmwareRev
OBJECT-TYPE
The firmware revision number of the local display.
1.3.6.1.4.1.318.1.1.21.1.3DisplayStringread-onlymandatory
apcLocalDisplayIdentOptions
OBJECT-TYPE
A display-specific string identifying options in the local display.
1.3.6.1.4.1.318.1.1.21.1.4DisplayStringread-onlymandatory
apcLocalDisplayIdentDateOfManufacture
OBJECT-TYPE
The date of manufacture of the local display, if available.
1.3.6.1.4.1.318.1.1.21.1.5DisplayStringread-onlymandatory
apcLocalDisplayIdentSerialNumber
OBJECT-TYPE
The serial number of the local display, if available.
1.3.6.1.4.1.318.1.1.21.1.6DisplayStringread-onlymandatory
apcLocalDisplayConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.21.2
apcLocalDisplayConfigAlarmBeeper
OBJECT-TYPE
The alarm beeper setting for the local display. When enabled, the alarm beeper will begin to sound whenever there a new alarm becomes active. The alarm beeper will continue to periodically sound until a key is pressed on the display.
1.3.6.1.4.1.318.1.1.21.2.1INTEGER {beeperDisabled(1), beeperEnabled(2)}read-writemandatory
apcLocalDisplayConfigBeeperVolume
OBJECT-TYPE
The volume setting of the beeper on the local display.
1.3.6.1.4.1.318.1.1.21.2.2INTEGER {beeperDisabled(1), beeperLow(2), beeperMedium(3), beeperHigh(4)}read-writemandatory
apcLocalDisplayConfigCheckLogIndicator
OBJECT-TYPE
The minimum level event severity level required to illuminate the check log light on the local display. notPresent (1) indicates that the display does not have a check log light.
1.3.6.1.4.1.318.1.1.21.2.3INTEGER {checklogNotPresent(1), checklogDisabled(2), checklogInformational(3), checklogWarning(4), checklogCritical(5)}read-writemandatory
apcLocalDisplayConfigKeyClick
OBJECT-TYPE
The key click setting of the local display.
1.3.6.1.4.1.318.1.1.21.2.4INTEGER {keyclickDisabled(1), keyclickEnabled(2)}read-writemandatory
apcLocalDisplayConfigContrast
OBJECT-TYPE
The contrast level of the local display.
1.3.6.1.4.1.318.1.1.21.2.5INTEGER {contrast1(1), contrast2(2), contrast3(3), contrast4(4), contrast5(5), contrast6(6), contrast7(7), contrast8(8)}read-writemandatory
isxModularDistribution
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22
isxModularDistInfo
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.1
isxModularDistInfoTableSize
OBJECT-TYPE
The number of entries in the isxModularDistInfoTable.
1.3.6.1.4.1.318.1.1.22.1.1INTEGERread-onlymandatory
isxModularDistInfoTable
OBJECT-TYPE
Allows for getting information about the modular distribution metering equipment.
1.3.6.1.4.1.318.1.1.22.1.2not-accessiblemandatory
isxModularDistInfoEntry
OBJECT-TYPE
An entry containing information about an individual metering segment.
1.3.6.1.4.1.318.1.1.22.1.2.1not-accessiblemandatory
isxModularDistInfoSegmentIndex
OBJECT-TYPE
The index of the metering segment.
1.3.6.1.4.1.318.1.1.22.1.2.1.1INTEGERread-onlymandatory
isxModularDistInfoMeterModelNumber
OBJECT-TYPE
The model number of the metering board for this segment.
1.3.6.1.4.1.318.1.1.22.1.2.1.2DisplayStringread-onlymandatory
isxModularDistInfoMeterSerialNumber
OBJECT-TYPE
The serial number of the metering board for this segment.
1.3.6.1.4.1.318.1.1.22.1.2.1.3DisplayStringread-onlymandatory
isxModularDistInfoMeterDateOfManufacture
OBJECT-TYPE
The date of manufacture for the metering board for this segment, in the format mm/dd/yyyy.
1.3.6.1.4.1.318.1.1.22.1.2.1.4DisplayStringread-onlymandatory
isxModularDistInfoMeterFirmwareRev
OBJECT-TYPE
The firmware revision number of the metering board for this segment.
1.3.6.1.4.1.318.1.1.22.1.2.1.5DisplayStringread-onlymandatory
isxModularDistInfoMeterHardwareRev
OBJECT-TYPE
The hardware revision number of the metering board for this segment.
1.3.6.1.4.1.318.1.1.22.1.2.1.6DisplayStringread-onlymandatory
isxModularDistModules
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.2
isxModularDistModuleInfoTableSize
OBJECT-TYPE
The number of entries in the isxModularDistModuleInfoTable.
1.3.6.1.4.1.318.1.1.22.2.1INTEGERread-onlymandatory
isxModularDistModuleInfoTable
OBJECT-TYPE
Allows for getting basic information about the distribution modules installed in the system.
1.3.6.1.4.1.318.1.1.22.2.2not-accessiblemandatory
isxModularDistModuleInfoEntry
OBJECT-TYPE
An entry containing information about a specific distribution module.
1.3.6.1.4.1.318.1.1.22.2.2.1not-accessiblemandatory
isxModularDistModuleInfoModIndex
OBJECT-TYPE
The number of the distribution module.
1.3.6.1.4.1.318.1.1.22.2.2.1.1INTEGERread-onlymandatory
isxModularDistModuleInfoAlarmStatus
OBJECT-TYPE
The status of this module. This reflects the indicator lamp(s) on the front of the module. A value of notPresent indicates that the module is not installed. A value of unknown indicates that there is no communication with the metering segment for this module.
1.3.6.1.4.1.318.1.1.22.2.2.1.2INTEGER {normal(1), warning(2), critical(3), notPresent(4), unknown(5)}read-onlymandatory
isxModularDistModuleInfoModelNumber
OBJECT-TYPE
The model number of the distribution module.
1.3.6.1.4.1.318.1.1.22.2.2.1.3DisplayStringread-onlymandatory
isxModularDistModuleInfoSerialNumber
OBJECT-TYPE
The serial number of the distribution module.
1.3.6.1.4.1.318.1.1.22.2.2.1.4DisplayStringread-onlymandatory
isxModularDistModuleInfoDateOfManufacture
OBJECT-TYPE
The date that the distribution module was manufactured.
1.3.6.1.4.1.318.1.1.22.2.2.1.5DisplayStringread-onlymandatory
isxModularDistModuleInfoNumCables
OBJECT-TYPE
The number of cables provided by this distribution module.
1.3.6.1.4.1.318.1.1.22.2.2.1.6INTEGERread-onlymandatory
isxModularDistModuleBreakerTableSize
OBJECT-TYPE
The number of entries in the isxModularDistModuleBreakerTable.
1.3.6.1.4.1.318.1.1.22.2.3INTEGERread-onlymandatory
isxModularDistModuleBreakerTable
OBJECT-TYPE
Allows for getting operational information about the distribution modules.
1.3.6.1.4.1.318.1.1.22.2.4not-accessiblemandatory
isxModularDistModuleBreakerEntry
OBJECT-TYPE
An entry containing information about a specific distribution modules and circuit breakers.
1.3.6.1.4.1.318.1.1.22.2.4.1not-accessiblemandatory
isxModularDistModuleBreakerModIndex
OBJECT-TYPE
The distribution module number.
1.3.6.1.4.1.318.1.1.22.2.4.1.1INTEGERread-onlymandatory
isxModularDistModuleBreakerPhaseIndex
OBJECT-TYPE
The index to an individual breaker in the distribution module. The index also corresponds to the system phase to which the breaker is attached.
1.3.6.1.4.1.318.1.1.22.2.4.1.2INTEGER {phaseL1(1), phaseL2(2), phaseL3(3)}read-onlymandatory
isxModularDistModuleBreakerAlarmStatus
OBJECT-TYPE
This is a bit map representing the active alarms for this breaker: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) b4 - Breaker is open (critical) If a bit is set, the corresponding alarm is active.
1.3.6.1.4.1.318.1.1.22.2.4.1.3INTEGERread-onlymandatory
isxModularDistModuleBreakerRating
OBJECT-TYPE
The current rating of the breaker.
1.3.6.1.4.1.318.1.1.22.2.4.1.4INTEGERread-onlymandatory
isxModularDistModuleBreakerPhysicalGroup
OBJECT-TYPE
Numeric value used to indicate that a breaker is a part of a multi-pole breaker. Breakers within a distribution module, with equivalent physical group numbers, may have their handles physically tied together. A value of 1 indicates breakers that are physically tied together as part of a multi-pole breaker. A value of 0 indicates a single-handle breaker that is not physically tied to another breaker.
1.3.6.1.4.1.318.1.1.22.2.4.1.5INTEGERread-onlymandatory
isxModularDistModuleBreakerCableNum
OBJECT-TYPE
Numeric value used to indicate the distribution cable to which this breaker is connected. These distribution cables are described in the table isxModularDistModuleOutputTable, and indexed by the OID isxModularDistModuleOutputCordIndex.
1.3.6.1.4.1.318.1.1.22.2.4.1.6INTEGERread-onlymandatory
isxModularDistModuleBreakerPosition
OBJECT-TYPE
The physical status of this breaker pole, either closed or open (including tripped).
1.3.6.1.4.1.318.1.1.22.2.4.1.7INTEGER {open(1), closed(2)}read-onlymandatory
isxModularDistModuleBreakerPositionAlarms
OBJECT-TYPE
Enable or disable breaker position alarms for this circuit breaker.
1.3.6.1.4.1.318.1.1.22.2.4.1.8INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistModuleBreakerCurrent
OBJECT-TYPE
The current flowing though this breaker. Measured in tenths of amps.
1.3.6.1.4.1.318.1.1.22.2.4.1.9INTEGERread-onlymandatory
isxModularDistModuleBreakerPercent
OBJECT-TYPE
The loading on this breaker as a percentage of the breaker's current rating. Expressed in tenths of percent.
1.3.6.1.4.1.318.1.1.22.2.4.1.10INTEGERread-onlymandatory
isxModularDistModuleBreakerPower
OBJECT-TYPE
The power being supplied through this breaker. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.22.2.4.1.11INTEGERread-onlymandatory
isxModularDistModuleOutputsTableSize
OBJECT-TYPE
The number of entries in the isxModularDistModuleOutputTable.
1.3.6.1.4.1.318.1.1.22.2.5INTEGERread-onlymandatory
isxModularDistModuleOutputTable
OBJECT-TYPE
Allows for getting and setting information related to the load equipment being fed by the distribution modules in the ISX Modular Distribution System.
1.3.6.1.4.1.318.1.1.22.2.6not-accessiblemandatory
isxModularDistModuleOutputEntry
OBJECT-TYPE
An entry containing information about a specific distribution module and its output distribution cables.
1.3.6.1.4.1.318.1.1.22.2.6.1not-accessiblemandatory
isxModularDistModuleOutputModIndex
OBJECT-TYPE
The number of the distribution module supplying power to the load equipment.
1.3.6.1.4.1.318.1.1.22.2.6.1.1INTEGERread-onlymandatory
isxModularDistModuleOutputNumCables
OBJECT-TYPE
The number of distribution cables provided by this module.
1.3.6.1.4.1.318.1.1.22.2.6.1.2INTEGERread-onlymandatory
isxModularDistModuleOutputCordIndex
OBJECT-TYPE
The index of an individual distribution cable supplied by this module.
1.3.6.1.4.1.318.1.1.22.2.6.1.3INTEGERread-onlymandatory
isxModularDistModuleOutputName
OBJECT-TYPE
A string describing the load equipment being supplied by this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.4DisplayStringread-writemandatory
isxModularDistModuleOutputLocation
OBJECT-TYPE
A string describing the location of equipment being supplied by distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.5DisplayStringread-writemandatory
isxModularDistModuleOutputStatus
OBJECT-TYPE
This reflects the worse case severity for alarms associated with this distribution cable. A value of notPresent indicates that the cable does not exist for this module. A value of unknown indicates that the there is no communication with the metering segment for this distribution cable's module.
1.3.6.1.4.1.318.1.1.22.2.6.1.6INTEGER {normal(1), warning(2), critical(3), notPresent(4), unknown(6)}read-onlymandatory
isxModularDistModuleOutputAlarmGeneration
OBJECT-TYPE
Enable or disable all alarm generation related to this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.7INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistModuleOutputBreakerMap
OBJECT-TYPE
This is a bit map representing the breaker poles within the module that are associated with this distribution cable. The following 3 bits are used to indicate the indices of the breakers feeding the cable: b0 - Module breaker L1 b1 - Module breaker L2 b2 - Module breaker L3 If a bit is set, the breaker is used to feed this distribution cable. These breakers are described in the table isxModularDistModuleBreakerTable, and indexed by the OID isxModularDistModuleBreakerPhaseIndex.
1.3.6.1.4.1.318.1.1.22.2.6.1.8INTEGERread-onlymandatory
isxModularDistModuleOutputThresholdMin
OBJECT-TYPE
When the current drops below this value a critical alarm will exist.
1.3.6.1.4.1.318.1.1.22.2.6.1.9INTEGERread-writemandatory
isxModularDistModuleOutputThresholdLow
OBJECT-TYPE
When the current drops below this value a warning alarm will exist.
1.3.6.1.4.1.318.1.1.22.2.6.1.10INTEGERread-writemandatory
isxModularDistModuleOutputThresholdHigh
OBJECT-TYPE
When the current exceeds this value a warning alarm will exist.
1.3.6.1.4.1.318.1.1.22.2.6.1.11INTEGERread-writemandatory
isxModularDistModuleOutputThresholdMax
OBJECT-TYPE
When the current exceeds this value a critical alarm will exist.
1.3.6.1.4.1.318.1.1.22.2.6.1.12INTEGERread-writemandatory
isxModularDistModuleOutputAlarmMinEnable
OBJECT-TYPE
Enable or disable minimum current alarm generation for this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.13INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistModuleOutputAlarmLowEnable
OBJECT-TYPE
Enable or disable low current alarm generation for this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.14INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistModuleOutputAlarmHighEnable
OBJECT-TYPE
Enable or disable high current alarm generation for this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.15INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistModuleOutputAlarmMaxEnable
OBJECT-TYPE
Enable or disable maximum current alarm generation for this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.16INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistModuleOutputCableLength
OBJECT-TYPE
The length of this distribution cable. Specified in tenths of meters.
1.3.6.1.4.1.318.1.1.22.2.6.1.17INTEGERread-onlymandatory
isxModularDistModuleOutputConnectorType
OBJECT-TYPE
A string describing the connector on the end of this distribution cable.
1.3.6.1.4.1.318.1.1.22.2.6.1.18DisplayStringread-onlymandatory
isxModularDistModuleOutputAvailableVoltages
OBJECT-TYPE
This is a bit map representing the voltages that are available at the connector. 6 bits are used to indicate the following: b0 - L1 b1 - L2 b2 - L3 b3 - L1-2 b4 - L2-3 b5 - L3-1
1.3.6.1.4.1.318.1.1.22.2.6.1.19INTEGERread-onlymandatory
isxModularDistModuleOutputTotalPower
OBJECT-TYPE
The total power being consumed by the load equipment supplied by this distribution cable. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.22.2.6.1.20INTEGERread-onlymandatory
isxModularDistModuleOutputKwhUsage
OBJECT-TYPE
The total energy consumed by the load equipment fed by this distribution cable. This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate OID, and may be cleared using the isxModularDistModuleOutputKwhReset OID. Measured in tenths of kWh.
1.3.6.1.4.1.318.1.1.22.2.6.1.21INTEGERread-onlymandatory
isxModularDistModuleOutputKwhReset
OBJECT-TYPE
Writing yes to this OID will reset the total kWh usage shown in the isxModularDistModuleOutputKwhUsage OID.
1.3.6.1.4.1.318.1.1.22.2.6.1.22INTEGER {no(1), yes(2)}read-writemandatory
isxModularDistModuleOutputKwhResetDate
OBJECT-TYPE
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
1.3.6.1.4.1.318.1.1.22.2.6.1.23DisplayStringread-onlymandatory
isxModularDistSubFeeds
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.3
isxModularDistSubFeedInfoTableSize
OBJECT-TYPE
The number of entries in the isxModularDistSubFeedInfoTable.
1.3.6.1.4.1.318.1.1.22.3.1INTEGERread-onlymandatory
isxModularDistSubFeedInfoTable
OBJECT-TYPE
Allows for getting information about distribution subfeed breakers.
1.3.6.1.4.1.318.1.1.22.3.2not-accessiblemandatory
isxModularDistSubFeedInfoEntry
OBJECT-TYPE
An entry containing information about a specific distribution subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1not-accessiblemandatory
isxModularDistSubFeedInfoSubIndex
OBJECT-TYPE
The index of an individual subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.1INTEGERread-onlymandatory
isxModularDistSubFeedInfoName
OBJECT-TYPE
A string describing the load equipment being supplied by this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.2DisplayStringread-writemandatory
isxModularDistSubFeedInfoLocation
OBJECT-TYPE
A string describing the location of the equipment being supplied by this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.3DisplayStringread-writemandatory
isxModularDistSubFeedInfoBreakerRating
OBJECT-TYPE
The current rating of this subfeed breaker.
1.3.6.1.4.1.318.1.1.22.3.2.1.4INTEGERread-onlymandatory
isxModularDistSubFeedInfoBreakerPosition
OBJECT-TYPE
The operational status of this breaker, either closed or open (including tripped).
1.3.6.1.4.1.318.1.1.22.3.2.1.5INTEGER {open(1), closed(2)}read-onlymandatory
isxModularDistSubFeedInfoAlarmStatus
OBJECT-TYPE
The worst case alarm status for this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.6INTEGER {normal(1), warning(2), critical(3)}read-onlymandatory
isxModularDistSubFeedInfoAlarmGeneration
OBJECT-TYPE
Enable or disable all alarm generation related to this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.7INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSubFeedInfoThresholdMin
OBJECT-TYPE
When the current drops below this value a critical alarm will exist.
1.3.6.1.4.1.318.1.1.22.3.2.1.8INTEGERread-writemandatory
isxModularDistSubFeedInfoThresholdLow
OBJECT-TYPE
When the current drops below this value a warning alarm will exist.
1.3.6.1.4.1.318.1.1.22.3.2.1.9INTEGERread-writemandatory
isxModularDistSubFeedInfoThresholdHigh
OBJECT-TYPE
When the current exceeds this value a warning alarm will exist.
1.3.6.1.4.1.318.1.1.22.3.2.1.10INTEGERread-writemandatory
isxModularDistSubFeedInfoThresholdMax
OBJECT-TYPE
When the current exceeds this value a critical alarm will exist.
1.3.6.1.4.1.318.1.1.22.3.2.1.11INTEGERread-writemandatory
isxModularDistSubFeedInfoAlarmMinEnable
OBJECT-TYPE
Enable or disable minimum current alarm generation for this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.12INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSubFeedInfoAlarmLowEnable
OBJECT-TYPE
Enable or disable low current alarm generation for this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.13INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSubFeedInfoAlarmHighEnable
OBJECT-TYPE
Enable or disable high current alarm generation for this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.14INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSubFeedInfoAlarmMaxEnable
OBJECT-TYPE
Enable or disable maximum current alarm generation for this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.15INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSubFeedInfoBreakerAlarmEnable
OBJECT-TYPE
Enable or disable breaker position alarms for this subfeed.
1.3.6.1.4.1.318.1.1.22.3.2.1.16INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSubFeedInfoTotalPower
OBJECT-TYPE
The total power being supplied by this subfeed. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.22.3.2.1.17INTEGERread-onlymandatory
isxModularDistSubFeedInfoKwhUsage
OBJECT-TYPE
The total energy consumed by the load equipment fed by this subfeed. This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate OID, and may be cleared using the isxModularDistSubFeedInfoKwhReset OID. Measured in tenths of kWh.
1.3.6.1.4.1.318.1.1.22.3.2.1.18INTEGERread-onlymandatory
isxModularDistSubFeedInfoKwhReset
OBJECT-TYPE
Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSubFeedInfoKwhUsage OID.
1.3.6.1.4.1.318.1.1.22.3.2.1.19INTEGER {no(1), yes(2)}read-writemandatory
isxModularDistSubFeedInfoKwhResetDate
OBJECT-TYPE
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
1.3.6.1.4.1.318.1.1.22.3.2.1.20DisplayStringread-onlymandatory
isxModularDistSubFeedLoadingTableSize
OBJECT-TYPE
The number of entries in the isxModularDistSubFeedLoadingTable.
1.3.6.1.4.1.318.1.1.22.3.3INTEGERread-onlymandatory
isxModularDistSubFeedLoadingTable
OBJECT-TYPE
Allows for getting subfeed phase loading information.
1.3.6.1.4.1.318.1.1.22.3.4not-accessiblemandatory
isxModularDistSubFeedLoadingEntry
OBJECT-TYPE
An entry containing data for an individual subfeed.
1.3.6.1.4.1.318.1.1.22.3.4.1not-accessiblemandatory
isxModularDistSubFeedLoadingSubIndex
OBJECT-TYPE
The index of an individual subfeed.
1.3.6.1.4.1.318.1.1.22.3.4.1.1INTEGERread-onlymandatory
isxModularDistSubFeedLoadingPhaseIndex
OBJECT-TYPE
Description of each input phase entry in the table.
1.3.6.1.4.1.318.1.1.22.3.4.1.2INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
isxModularDistSubFeedLoadingAlarmStatus
OBJECT-TYPE
This is a bit map representing the active alarms for this subfeed: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) b4 - Breaker is open (critical) If a bit is set, the corresponding alarm is active.
1.3.6.1.4.1.318.1.1.22.3.4.1.3INTEGERread-onlymandatory
isxModularDistSubFeedLoadingCurrent
OBJECT-TYPE
The current flowing though this subfeed phase. Measured in tenths of amps.
1.3.6.1.4.1.318.1.1.22.3.4.1.4INTEGERread-onlymandatory
isxModularDistSubFeedLoadingPercent
OBJECT-TYPE
The loading on this subfeed phase as a percentage of the subfeed's current rating. Expressed in tenths of percent.
1.3.6.1.4.1.318.1.1.22.3.4.1.5INTEGERread-onlymandatory
isxModularDistSubFeedLoadingPower
OBJECT-TYPE
The power being supplied by this subfeed phase. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.22.3.4.1.6INTEGERread-onlymandatory
isxModularDistTotals
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.4
isxModularDistSysVoltage
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.4.1
isxModularDistSysOutputVoltageNominalLineToNeutral
OBJECT-TYPE
The nominal line-to-neutral voltage available at the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.1.1INTEGERread-onlymandatory
isxModularDistSysOutputVoltageNominalLineToLine
OBJECT-TYPE
The nominal line-to-line voltage available at the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.1.2INTEGERread-onlymandatory
isxModularDistSysOutputNominalFrequency
OBJECT-TYPE
The nominal system output frequency. Measured in tenths of Hertz.
1.3.6.1.4.1.318.1.1.22.4.1.3INTEGERread-onlymandatory
isxModularDistSysOutputFrequency
OBJECT-TYPE
The system output frequency in tenths of Hertz. -1 if not available.
1.3.6.1.4.1.318.1.1.22.4.1.4INTEGERread-onlymandatory
isxModularDistSysOutputVoltageMonitoring
OBJECT-TYPE
Indicates whether or not output voltage alarm generation is present.
1.3.6.1.4.1.318.1.1.22.4.1.5INTEGER {notPresent(1), present(2)}read-onlymandatory
isxModularDistSysOutputVoltageThresholdMin
OBJECT-TYPE
When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. This value is returned as a positive number which represents a negative percentage. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.1.6INTEGERread-writemandatory
isxModularDistSysOutputVoltageThresholdLow
OBJECT-TYPE
When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. This value is returned as a positive number which represents a negative percentage. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.1.7INTEGERread-writemandatory
isxModularDistSysOutputVoltageThresholdHigh
OBJECT-TYPE
When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.1.8INTEGERread-writemandatory
isxModularDistSysOutputVoltageThresholdMax
OBJECT-TYPE
When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist. Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLineToNeutral. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.1.9INTEGERread-writemandatory
isxModularDistSysOutputVoltageAlarmMinEnable
OBJECT-TYPE
Enable or disable minimum voltage alarm generation for the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.1.10INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysOutputVoltageAlarmLowEnable
OBJECT-TYPE
Enable or disable low voltage alarm generation for the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.1.11INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysOutputVoltageAlarmHighEnable
OBJECT-TYPE
Enable or disable high voltage alarm generation for the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.1.12INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysOutputVoltageAlarmMaxEnable
OBJECT-TYPE
Enable or disable maximum voltage alarm generation for the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.1.13INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysOutputVoltageFrequencyTolerance
OBJECT-TYPE
The circuit panel output frequency tolerance in Hertz. When the system output frequency deviates from the nominal by more than this range, a critical alarm will be generated.
1.3.6.1.4.1.318.1.1.22.4.1.14INTEGER {freqToleranceOff(1), freqTolerancePointTwo(2), freqTolerancePointFive(3), freqToleranceOne(4), freqToleranceOnePointFive(5), freqToleranceTwo(6), freqToleranceThree(7), freqToleranceFour(8), freqToleranceFive(9), freqToleranceNine(10), freqToleranceNotAvailable(11)}read-writemandatory
isxModularDistSysVoltageTable
OBJECT-TYPE
Allows for getting the system output voltage information.
1.3.6.1.4.1.318.1.1.22.4.1.15not-accessiblemandatory
isxModularDistSysVoltageEntry
OBJECT-TYPE
An entry containing data for an individual system output phase.
1.3.6.1.4.1.318.1.1.22.4.1.15.1not-accessiblemandatory
isxModularDistSysVoltagePhaseIndex
OBJECT-TYPE
Description of each phase entry in the table.
1.3.6.1.4.1.318.1.1.22.4.1.15.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
isxModularDistSysVoltageAlarmStatus
OBJECT-TYPE
This is a bit map representing the active alarms for this output phase: b0 - Minimum voltage threshold exceeded (critical) b1 - Low voltage threshold exceeded (warning) b2 - High voltage threshold exceeded (warning) b3 - Maximum voltage threshold exceeded (critical) If a bit is set, the corresponding alarm is active.
1.3.6.1.4.1.318.1.1.22.4.1.15.1.2INTEGERread-onlymandatory
isxModularDistSysVoltageLtoN
OBJECT-TYPE
Line-to-neutral system output voltage available at the distribution panel. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.22.4.1.15.1.3INTEGERread-onlymandatory
isxModularDistSysVoltageLtoL
OBJECT-TYPE
Line-to-line system output voltage available at the distribution panel. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.22.4.1.15.1.4INTEGERread-onlymandatory
isxModularDistSysCurrent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.4.2
isxModularDistSysCurrentRating
OBJECT-TYPE
The 100 percent current rating of the distribution panel.
1.3.6.1.4.1.318.1.1.22.4.2.1INTEGERread-onlymandatory
isxModularDistSysCurrentMonitoring
OBJECT-TYPE
Indicates whether or not total output current measurements and alarm generation are present.
1.3.6.1.4.1.318.1.1.22.4.2.2INTEGER {notPresent(1), present(2)}read-onlymandatory
isxModularDistSysCurrentThresholdMin
OBJECT-TYPE
When total system current in any phase drops below this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.2.3INTEGERread-writemandatory
isxModularDistSysCurrentThresholdLow
OBJECT-TYPE
When total system current in any phase drops below this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.2.4INTEGERread-writemandatory
isxModularDistSysCurrentThresholdHigh
OBJECT-TYPE
When total system current in any phase exceeds this value a warning alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.2.5INTEGERread-writemandatory
isxModularDistSysCurrentThresholdMax
OBJECT-TYPE
When total system current in any phase exceeds this value a critical alarm will exist. Specified as a percent of the panel rating, isxModularDistSysCurrentRating. A value of -1 indicates that the threshold is not available in the device.
1.3.6.1.4.1.318.1.1.22.4.2.6INTEGERread-writemandatory
isxModularDistSysCurrentAlarmMinEnable
OBJECT-TYPE
Enable or disable minimum total output current alarm generation.
1.3.6.1.4.1.318.1.1.22.4.2.7INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysCurrentAlarmLowEnable
OBJECT-TYPE
Enable or disable low total output current alarm generation.
1.3.6.1.4.1.318.1.1.22.4.2.8INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysCurrentAlarmHighEnable
OBJECT-TYPE
Enable or disable high total output current alarm generation.
1.3.6.1.4.1.318.1.1.22.4.2.9INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysCurrentAlarmMaxEnable
OBJECT-TYPE
Enable or disable maximum total output current alarm generation.
1.3.6.1.4.1.318.1.1.22.4.2.10INTEGER {disabled(1), enabled(2)}read-writemandatory
isxModularDistSysCurrentTable
OBJECT-TYPE
Allows for getting the total system phase current information.
1.3.6.1.4.1.318.1.1.22.4.2.11not-accessiblemandatory
isxModularDistSysCurrentEntry
OBJECT-TYPE
An entry containing data for an individual system output phase.
1.3.6.1.4.1.318.1.1.22.4.2.11.1not-accessiblemandatory
isxModularDistSysCurrentPhaseIndex
OBJECT-TYPE
Description of each phase entry in the table.
1.3.6.1.4.1.318.1.1.22.4.2.11.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
isxModularDistSysCurrentAlarmStatus
OBJECT-TYPE
This is a bit map representing the active alarms for this output phase: b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (warning) b3 - Maximum current threshold exceeded (critical) If a bit is set, the corresponding alarm is active.
1.3.6.1.4.1.318.1.1.22.4.2.11.1.2INTEGERread-onlymandatory
isxModularDistSysCurrentAmps
OBJECT-TYPE
The current flowing though this system output phase. Measured in tenths of amps.
1.3.6.1.4.1.318.1.1.22.4.2.11.1.3INTEGERread-onlymandatory
isxModularDistSysCurrentPercent
OBJECT-TYPE
The loading on this system output phase as a percentage of the panel current rating. Expressed in tenths of percent.
1.3.6.1.4.1.318.1.1.22.4.2.11.1.4INTEGERread-onlymandatory
isxModularDistSysPower
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.22.4.3
isxModularDistSysPowerTotal
OBJECT-TYPE
The total system power being supplied. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.22.4.3.1INTEGERread-onlymandatory
isxModularDistSysPowerKwhUsage
OBJECT-TYPE
The total system energy consumed by the load equipment. This is the total since the date specified in the isxModularDistSysOutputKwhResetDate OID, and may be cleared using the isxModularDistSysOutputKwhReset OID. Measured in tenths of kWh.
1.3.6.1.4.1.318.1.1.22.4.3.2INTEGERread-onlymandatory
isxModularDistSysPowerKwhReset
OBJECT-TYPE
Writing yes to this OID will reset the total kWh usage shown in the isxModularDistSysPowerKwhUsage OID.
1.3.6.1.4.1.318.1.1.22.4.3.3INTEGER {no(1), yes(2)}read-writemandatory
isxModularDistSysPowerKwhResetDate
OBJECT-TYPE
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
1.3.6.1.4.1.318.1.1.22.4.3.4DisplayStringread-onlymandatory
isxModularDistSysPowerTable
OBJECT-TYPE
Allows for getting the total system phase power loading information.
1.3.6.1.4.1.318.1.1.22.4.3.5not-accessiblemandatory
isxModularDistSysPowerEntry
OBJECT-TYPE
An entry containing data for an individual system output phase.
1.3.6.1.4.1.318.1.1.22.4.3.5.1not-accessiblemandatory
isxModularDistSysPowerPhaseIndex
OBJECT-TYPE
Description of each phase entry in the table.
1.3.6.1.4.1.318.1.1.22.4.3.5.1.1INTEGER {phase1(1), phase2(2), phase3(3)}read-onlymandatory
isxModularDistSysPowerKw
OBJECT-TYPE
The power being supplied by this system output phase. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.22.4.3.5.1.2INTEGERread-onlymandatory
isxModularDistSysPowerKwhPhaseUsage
OBJECT-TYPE
The energy consumed by the load equipment on this system output phase. This is the total since the date specified in the isxModularDistSysPowerKwhResetDate OID, and may be cleared using the isxModularDistSysPowerKwhReset OID. Measured in tenths of kWh.
1.3.6.1.4.1.318.1.1.22.4.3.5.1.3INTEGERread-onlymandatory
isxModularPdu
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.23
isxModularPduIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.23.1
isxModularPduIdentModelNumber
OBJECT-TYPE
A character string identifying the model number of the PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.23.1.1DisplayStringread-onlymandatory
isxModularPduIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the PDU. This value is set at the factory.
1.3.6.1.4.1.318.1.1.23.1.2DisplayStringread-onlymandatory
isxModularPduIdentDateOfManufacture
OBJECT-TYPE
The date when the PDU was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.23.1.3DisplayStringread-onlymandatory
isxModularPduIdentMonitorCardSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the PDU monitor card. This value is set at the factory.
1.3.6.1.4.1.318.1.1.23.1.4DisplayStringread-onlymandatory
isxModularPduIdentMonitorCardHardwareRev
OBJECT-TYPE
The hardware revision of the PDU monitor card. This value is set at the factory.
1.3.6.1.4.1.318.1.1.23.1.5DisplayStringread-onlymandatory
isxModularPduIdentMonitorCardFirmwareAppRev
OBJECT-TYPE
An ID string identifying the application firmware revision of the PDU monitor card.
1.3.6.1.4.1.318.1.1.23.1.6DisplayStringread-onlymandatory
isxModularPduIdentMonitorCardFirmwareAppOSRev
OBJECT-TYPE
An ID string identifying the application operating system firmware revision of the PDU monitor card.
1.3.6.1.4.1.318.1.1.23.1.7DisplayStringread-onlymandatory
isxModularPduDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.23.2
isxModularPduDeviceTransformerPresent
OBJECT-TYPE
Indicates the type of transformer present in this PDU.
1.3.6.1.4.1.318.1.1.23.2.1INTEGER {notPresent(1), isoXfmrPresent(2), autoXfmrPresent(3)}read-onlymandatory
isxModularPduDeviceServiceType
OBJECT-TYPE
The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye).
1.3.6.1.4.1.318.1.1.23.2.2INTEGER {threeWire(1), fourWire(2)}read-onlymandatory
isxModularPduDeviceFansPresent
OBJECT-TYPE
Indicates whether or not cooling fans are installed in the PDU.
1.3.6.1.4.1.318.1.1.23.2.3INTEGER {notPresent(1), present(2)}read-onlymandatory
isxModularPduDeviceNominalMainInputVoltage
OBJECT-TYPE
The nominal main input voltage to the system. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. -1 if main input voltage is not being measured.
1.3.6.1.4.1.318.1.1.23.2.4INTEGERread-onlymandatory
isxModularPduStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.23.3
isxModularPduAlarmStatus
OBJECT-TYPE
The overall status (worst case) of this PDU.
1.3.6.1.4.1.318.1.1.23.3.1INTEGER {normal(1), warning(2), critical(3)}read-onlymandatory
isxModularPduTransformerTempStatus
OBJECT-TYPE
Indicates if the PDU isolation transformer is over temperature.
1.3.6.1.4.1.318.1.1.23.3.2INTEGER {normal(1), overtemp(2), noTransformerPresent(3), unknown(4)}read-onlymandatory
isxModularPduFanStatus
OBJECT-TYPE
Indicates if one or more of the PDU's cooling fans have failed.
1.3.6.1.4.1.318.1.1.23.3.3INTEGER {normal(1), failed(2), noCoolingFansPresent(3), unknown(4)}read-onlymandatory
universalInputOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.25
uioSensor
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.25.1
uioSensorStatusTableSize
OBJECT-TYPE
The number of entries in the uioSensorStatusTable.
1.3.6.1.4.1.318.1.1.25.1.1INTEGERread-onlymandatory
uioSensorStatusTable
OBJECT-TYPE
Allows for getting sensor status information.
1.3.6.1.4.1.318.1.1.25.1.2not-accessiblemandatory
uioSensorStatusEntry
OBJECT-TYPE
The unit from which to get data.
1.3.6.1.4.1.318.1.1.25.1.2.1not-accessiblemandatory
uioSensorStatusPortID
OBJECT-TYPE
The ID of the port to which the sensor is attached.
1.3.6.1.4.1.318.1.1.25.1.2.1.1INTEGERread-onlymandatory
uioSensorStatusSensorID
OBJECT-TYPE
The ID of the sensor.
1.3.6.1.4.1.318.1.1.25.1.2.1.2INTEGERread-onlymandatory
uioSensorStatusSensorName
OBJECT-TYPE
The sensor name.
1.3.6.1.4.1.318.1.1.25.1.2.1.3DisplayStringread-onlymandatory
uioSensorStatusSensorLocation
OBJECT-TYPE
The location of the sensor.
1.3.6.1.4.1.318.1.1.25.1.2.1.4DisplayStringread-onlymandatory
uioSensorStatusTemperatureDegF
OBJECT-TYPE
The sensor's current temperature reading in degrees Fahrenheit. -1 indicates an invalid reading due to lost communications.
1.3.6.1.4.1.318.1.1.25.1.2.1.5INTEGERread-onlymandatory
uioSensorStatusTemperatureDegC
OBJECT-TYPE
The sensor's current temperature reading in degrees Celsius. -1 indicates an invalid reading due to lost communications.
1.3.6.1.4.1.318.1.1.25.1.2.1.6INTEGERread-onlymandatory
uioSensorStatusHumidity
OBJECT-TYPE
The sensor's current humidity reading in percent relative humidity. -1 indicates an invalid reading due to either a sensor that doesn't read humidity or lost communications.
1.3.6.1.4.1.318.1.1.25.1.2.1.7INTEGERread-onlymandatory
uioSensorStatusViolationStatus
OBJECT-TYPE
The violation status of the sensor. This integer should be interpreted as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is present, and '0' if the condition is not present. Bit Hex. Value Description 1 0x0001 Maximum temperature exceeded. 2 0x0002 High temperature exceeded. 3 0x0004 Low temperature exceeded. 4 0x0008 Minimum temperature exceeded. 5 0x0010 Short-term increasing temperature rate exceeded (Not used). 6 0x0020 Short-term decreasing temperature rate exceeded (Not used). 7 0x0040 Long-term increasing temperature rate exceeded (Not used). 8 0x0080 Long-term decreasing temperature rate exceeded (Not used). 9 0x0100 Maximum humidity exceeded. 10 0x0200 High humidity exceeded. 11 0x0400 Low humidity exceeded. 12 0x0800 Minimum humidity exceeded.
1.3.6.1.4.1.318.1.1.25.1.2.1.8INTEGERread-onlymandatory
uioSensorStatusAlarmStatus
OBJECT-TYPE
The alarm status of the sensor.
1.3.6.1.4.1.318.1.1.25.1.2.1.9INTEGER {uioNormal(1), uioWarning(2), uioCritical(3), sensorStatusNotApplicable(4)}read-onlymandatory
uioSensorStatusCommStatus
OBJECT-TYPE
The communications status of the sensor.
1.3.6.1.4.1.318.1.1.25.1.2.1.10INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
uioSensorConfigTableSize
OBJECT-TYPE
The number of entries in the uioSensorConfigTable.
1.3.6.1.4.1.318.1.1.25.1.3INTEGERread-onlymandatory
uioSensorConfigTable
OBJECT-TYPE
Allows for configuring the sensor.
1.3.6.1.4.1.318.1.1.25.1.4not-accessiblemandatory
uioSensorConfigEntry
OBJECT-TYPE
The sensor from which to get configuration.
1.3.6.1.4.1.318.1.1.25.1.4.1not-accessiblemandatory
uioSensorConfigPortID
OBJECT-TYPE
The ID of the port to which the sensor is attached.
1.3.6.1.4.1.318.1.1.25.1.4.1.1INTEGERread-onlymandatory
uioSensorConfigSensorID
OBJECT-TYPE
The ID of the sensor.
1.3.6.1.4.1.318.1.1.25.1.4.1.2INTEGERread-onlymandatory
uioSensorConfigSensorName
OBJECT-TYPE
The sensor name.
1.3.6.1.4.1.318.1.1.25.1.4.1.3DisplayStringread-writemandatory
uioSensorConfigSensorLocation
OBJECT-TYPE
The location of the sensor.
1.3.6.1.4.1.318.1.1.25.1.4.1.4DisplayStringread-writemandatory
uioSensorConfigMinTemperatureThreshold
OBJECT-TYPE
The minimum (critical) temperature alarm threshold for the probe in degrees C. Must be lower than the low threshold to ensure proper sensor alarm behavior.
1.3.6.1.4.1.318.1.1.25.1.4.1.5INTEGERread-writemandatory
uioSensorConfigLowTemperatureThreshold
OBJECT-TYPE
The low (warning) temperature alarm threshold for the probe in degrees C. Must be higher than the minimum threshold and lower than the high threshold to ensure proper sensor alarm behavior.
1.3.6.1.4.1.318.1.1.25.1.4.1.6INTEGERread-writemandatory
uioSensorConfigHighTemperatureThreshold
OBJECT-TYPE
The high (warning) temperature alarm threshold for the probe in degrees C. Must be lower than the maximum threshold and higher than the low threshold to ensure proper sensor alarm behavior.
1.3.6.1.4.1.318.1.1.25.1.4.1.7INTEGERread-writemandatory
uioSensorConfigMaxTemperatureThreshold
OBJECT-TYPE
The maximum (critical) temperature alarm threshold for the probe in degrees C. Must be higher than the high threshold to ensure proper sensor alarm behavior.
1.3.6.1.4.1.318.1.1.25.1.4.1.8INTEGERread-writemandatory
uioSensorConfigTemperatureHysteresis
OBJECT-TYPE
The number of degrees C beyond the temperature thresholds at which an active temperature alarm will be cleared. This value applies to all temperature thresholds.
1.3.6.1.4.1.318.1.1.25.1.4.1.9INTEGERread-writemandatory
uioSensorConfigMinTemperatureEnable
OBJECT-TYPE
The minimum temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.10INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigLowTemperatureEnable
OBJECT-TYPE
The low temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.11INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigHighTemperatureEnable
OBJECT-TYPE
The high temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.12INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigMaxTemperatureEnable
OBJECT-TYPE
The maximum temperature alarm enable/disable for the sensor. 1 - disabled 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.13INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigMinHumidityThreshold
OBJECT-TYPE
The minimum (critical) humidity alarm threshold for the probe in percent relative humidity. Must be lower than the low threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity.
1.3.6.1.4.1.318.1.1.25.1.4.1.14INTEGERread-writemandatory
uioSensorConfigLowHumidityThreshold
OBJECT-TYPE
The low (warning) humidity alarm threshold for the probe in percent relative humidity. Must be higher than the minimum threshold and lower than the high threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity.
1.3.6.1.4.1.318.1.1.25.1.4.1.15INTEGERread-writemandatory
uioSensorConfigHighHumidityThreshold
OBJECT-TYPE
The high (warning) humidity alarm threshold for the probe in percent relative humidity. Must be lower than the maximum threshold and higher than the low threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity.
1.3.6.1.4.1.318.1.1.25.1.4.1.16INTEGERread-writemandatory
uioSensorConfigMaxHumidityThreshold
OBJECT-TYPE
The maximum (critical) humidity alarm threshold for the probe in percent relative humidity. Must be higher than the high threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity.
1.3.6.1.4.1.318.1.1.25.1.4.1.17INTEGERread-writemandatory
uioSensorConfigHumidityHysteresis
OBJECT-TYPE
The number of percent relative humidity beyond the humidity thresholds at which an active humidity alarm will be cleared. This value applies to all humidity thresholds. -1 if the sensor doesn't read humidity.
1.3.6.1.4.1.318.1.1.25.1.4.1.18INTEGERread-writemandatory
uioSensorConfigMinHumidityEnable
OBJECT-TYPE
The minimum humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.19INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigLowHumidityEnable
OBJECT-TYPE
The low humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.20INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigHighHumidityEnable
OBJECT-TYPE
The high humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.21INTEGER {disabled(1), enabled(2)}read-writemandatory
uioSensorConfigMaxHumidityEnable
OBJECT-TYPE
The maximum humidity alarm enable/disable for the sensor. 1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled
1.3.6.1.4.1.318.1.1.25.1.4.1.22INTEGER {disabled(1), enabled(2)}read-writemandatory
uioInputContact
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.25.2
uioInputContactStatusTableSize
OBJECT-TYPE
The number of entries in the uioInputContactStatusTable.
1.3.6.1.4.1.318.1.1.25.2.1INTEGERread-onlymandatory
uioInputContactStatusTable
OBJECT-TYPE
Allows for getting input contact status information.
1.3.6.1.4.1.318.1.1.25.2.2not-accessiblemandatory
uioInputContactStatusEntry
OBJECT-TYPE
The input contact from which to get data.
1.3.6.1.4.1.318.1.1.25.2.2.1not-accessiblemandatory
uioInputContactStatusPortID
OBJECT-TYPE
The ID of the port to which the input contact is attached.
1.3.6.1.4.1.318.1.1.25.2.2.1.1INTEGERread-onlymandatory
uioInputContactStatusContactID
OBJECT-TYPE
The ID of the input contact on the module.
1.3.6.1.4.1.318.1.1.25.2.2.1.2INTEGERread-onlymandatory
uioInputContactStatusContactName
OBJECT-TYPE
The input contact name.
1.3.6.1.4.1.318.1.1.25.2.2.1.3DisplayStringread-onlymandatory
uioInputContactStatusContactLocation
OBJECT-TYPE
The location of the input contact.
1.3.6.1.4.1.318.1.1.25.2.2.1.4DisplayStringread-onlymandatory
uioInputContactStatusCurrentState
OBJECT-TYPE
The current state of the input contact.
1.3.6.1.4.1.318.1.1.25.2.2.1.5INTEGER {uioInputClosed(1), uioInputOpen(2), uioInputDisabled(3), inputStateNotApplicable(4)}read-onlymandatory
uioInputContactStatusAlarmStatus
OBJECT-TYPE
The alarm status of the input contact.
1.3.6.1.4.1.318.1.1.25.2.2.1.6INTEGER {uioNormal(1), uioWarning(2), uioCritical(3), inputStatusNotApplicable(4)}read-onlymandatory
uioInputContactStatusCommStatus
OBJECT-TYPE
The communications status of the input contact.
1.3.6.1.4.1.318.1.1.25.2.2.1.7INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
uioInputContactConfigTableSize
OBJECT-TYPE
The number of entries in the uioInputContactConfigTable.
1.3.6.1.4.1.318.1.1.25.2.3INTEGERread-onlymandatory
uioInputContactConfigTable
OBJECT-TYPE
Allows for configuring the input contacts.
1.3.6.1.4.1.318.1.1.25.2.4not-accessiblemandatory
uioInputContactConfigEntry
OBJECT-TYPE
The input contact from which to get configuration.
1.3.6.1.4.1.318.1.1.25.2.4.1not-accessiblemandatory
uioInputContactConfigPortID
OBJECT-TYPE
The ID of the port to which the input contact is attached.
1.3.6.1.4.1.318.1.1.25.2.4.1.1INTEGERread-onlymandatory
uioInputContactConfigContactID
OBJECT-TYPE
The ID of the input contact on the module.
1.3.6.1.4.1.318.1.1.25.2.4.1.2INTEGERread-onlymandatory
uioInputContactConfigContactName
OBJECT-TYPE
The input contact name.
1.3.6.1.4.1.318.1.1.25.2.4.1.3DisplayStringread-writemandatory
uioInputContactConfigContactLocation
OBJECT-TYPE
The location of the input contact.
1.3.6.1.4.1.318.1.1.25.2.4.1.4DisplayStringread-writemandatory
uioInputContactConfigEnable
OBJECT-TYPE
Enable or disable this input contact. 1 - disabled 2 - enabled
1.3.6.1.4.1.318.1.1.25.2.4.1.5INTEGER {uioInputContactDisabled(1), uioInputContactEnabled(2)}read-writemandatory
uioInputContactConfigNormalState
OBJECT-TYPE
The normal (non-alarm) state of the input contact. 1 - normally open 2 - normally closed
1.3.6.1.4.1.318.1.1.25.2.4.1.6INTEGER {uioInputNormallyOpen(1), uioInputNormallyClosed(2)}read-writemandatory
uioInputContactConfigSeverity
OBJECT-TYPE
The severity of the alarm that this input contact will generate in the abnormal state. 1 - critical severity 2 - warning severity
1.3.6.1.4.1.318.1.1.25.2.4.1.7INTEGER {uioInputCriticalSeverity(1), uioInputWarningSeverity(2)}read-writemandatory
uioOutputRelay
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.25.3
uioOutputRelayStatusTableSize
OBJECT-TYPE
The number of entries in the uioOutputRelayStatusTable.
1.3.6.1.4.1.318.1.1.25.3.1INTEGERread-onlymandatory
uioOutputRelayStatusTable
OBJECT-TYPE
Allows for getting output relay status information.
1.3.6.1.4.1.318.1.1.25.3.2not-accessiblemandatory
uioOutputRelayStatusEntry
OBJECT-TYPE
The unit from which to get data.
1.3.6.1.4.1.318.1.1.25.3.2.1not-accessiblemandatory
uioOutputRelayStatusPortID
OBJECT-TYPE
The ID of the port to which the output relay is attached.
1.3.6.1.4.1.318.1.1.25.3.2.1.1INTEGERread-onlymandatory
uioOutputRelayStatusRelayID
OBJECT-TYPE
The ID of the output relay on the module.
1.3.6.1.4.1.318.1.1.25.3.2.1.2INTEGERread-onlymandatory
uioOutputRelayStatusRelayName
OBJECT-TYPE
The output relay name.
1.3.6.1.4.1.318.1.1.25.3.2.1.3DisplayStringread-onlymandatory
uioOutputRelayStatusRelayLocation
OBJECT-TYPE
The location of the output relay.
1.3.6.1.4.1.318.1.1.25.3.2.1.4DisplayStringread-onlymandatory
uioOutputRelayStatusCurrentState
OBJECT-TYPE
The current state of the output relay.
1.3.6.1.4.1.318.1.1.25.3.2.1.5INTEGER {uioOutputClosed(1), uioOutputOpen(2), outputStateNotApplicable(3)}read-onlymandatory
uioOutputRelayStatusAlarmStatus
OBJECT-TYPE
The alarm status of the output relay.
1.3.6.1.4.1.318.1.1.25.3.2.1.6INTEGER {uioNormal(1), uioWarning(2), uioCritical(3), inputStatusNotApplicable(4)}read-onlymandatory
uioOutputRelayStatusCommStatus
OBJECT-TYPE
The communications status of the output relay.
1.3.6.1.4.1.318.1.1.25.3.2.1.7INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
uioOutputRelayConfigTableSize
OBJECT-TYPE
The number of entries in the uioOutputRelayConfigTable.
1.3.6.1.4.1.318.1.1.25.3.3INTEGERread-onlymandatory
uioOutputRelayConfigTable
OBJECT-TYPE
Allows for configuring the output relay.
1.3.6.1.4.1.318.1.1.25.3.4not-accessiblemandatory
uioOutputRelayConfigEntry
OBJECT-TYPE
The unit from which to get configuration.
1.3.6.1.4.1.318.1.1.25.3.4.1not-accessiblemandatory
uioOutputRelayConfigPortID
OBJECT-TYPE
The ID of the port to which the output relay is attached.
1.3.6.1.4.1.318.1.1.25.3.4.1.1INTEGERread-onlymandatory
uioOutputRelayConfigRelayID
OBJECT-TYPE
The ID of the output relay on the module.
1.3.6.1.4.1.318.1.1.25.3.4.1.2INTEGERread-onlymandatory
uioOutputRelayConfigRelayName
OBJECT-TYPE
The output relay name.
1.3.6.1.4.1.318.1.1.25.3.4.1.3DisplayStringread-writemandatory
uioOutputRelayConfigRelayLocation
OBJECT-TYPE
The location of the output relay.
1.3.6.1.4.1.318.1.1.25.3.4.1.4DisplayStringread-writemandatory
uioOutputRelayConfigNormalState
OBJECT-TYPE
The normal state of the output relay. 1 - normally open 2 - normally closed
1.3.6.1.4.1.318.1.1.25.3.4.1.5INTEGER {uioOutputNormallyOpen(1), uioOutputNormallyClosed(2)}read-writemandatory
uioOutputRelayConfigControlState
OBJECT-TYPE
Close or open the output relay for testing purposes. Always returns 1 when read. 1 - close output relay 2 - open output relay
1.3.6.1.4.1.318.1.1.25.3.4.1.6INTEGER {uioOutputClose(1), uioOutputOpen(2)}read-writemandatory
uioOutputRelayConfigDelay
OBJECT-TYPE
The time a selected alarm condition must exist before the output relay is activated. Valid values are whole seconds from 0 to 65535.
1.3.6.1.4.1.318.1.1.25.3.4.1.7TimeTicksread-writemandatory
uioOutputRelayConfigHold
OBJECT-TYPE
The minimum time the output relay remains activated after the alarm occurs. Valid values are whole seconds from 0 to 65535.
1.3.6.1.4.1.318.1.1.25.3.4.1.8TimeTicksread-writemandatory
rPDU2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26
rPDU2IdentTableSize
OBJECT-TYPE
The total number of Rack PDUs
1.3.6.1.4.1.318.1.1.26.1INTEGERread-onlymandatory
rPDU2IdentTable
OBJECT-TYPE
A table of Rack PDU identification data
1.3.6.1.4.1.318.1.1.26.2not-accessiblemandatory
rPDU2IdentEntry
OBJECT-TYPE
Identification data from Rack PDU being queried
1.3.6.1.4.1.318.1.1.26.2.1not-accessiblemandatory
rPDU2IdentIndex
OBJECT-TYPE
The index to the Rack PDU identification table entry
1.3.6.1.4.1.318.1.1.26.2.1.1INTEGERread-onlymandatory
rPDU2IdentModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.2.1.2INTEGERread-onlymandatory
rPDU2IdentName
OBJECT-TYPE
A user-defined string identifying the Rack PDU
1.3.6.1.4.1.318.1.1.26.2.1.3DisplayStringread-onlymandatory
rPDU2IdentLocation
OBJECT-TYPE
A user-defined string identifying the location of the Rack PDU
1.3.6.1.4.1.318.1.1.26.2.1.4DisplayStringread-onlymandatory
rPDU2IdentHardwareRev
OBJECT-TYPE
The Rack PDU hardware version
1.3.6.1.4.1.318.1.1.26.2.1.5DisplayStringread-onlymandatory
rPDU2IdentFirmwareRev
OBJECT-TYPE
The Rack PDU firmware version
1.3.6.1.4.1.318.1.1.26.2.1.6DisplayStringread-onlymandatory
rPDU2IdentDateOfManufacture
OBJECT-TYPE
The date the Rack PDU was manufactured in mm/dd/yyyy format
1.3.6.1.4.1.318.1.1.26.2.1.7DisplayStringread-onlymandatory
rPDU2IdentModelNumber
OBJECT-TYPE
The Rack PDU model number
1.3.6.1.4.1.318.1.1.26.2.1.8DisplayStringread-onlymandatory
rPDU2IdentSerialNumber
OBJECT-TYPE
The Rack PDU serial number
1.3.6.1.4.1.318.1.1.26.2.1.9DisplayStringread-onlymandatory
rPDU2IdentContact
OBJECT-TYPE
A user-defined string identifying the person to contact regarding the Rack PDU
1.3.6.1.4.1.318.1.1.26.2.1.10DisplayStringread-onlymandatory
rPDU2IdentBootMonitorRev
OBJECT-TYPE
The Rack PDU Boot Monitor version
1.3.6.1.4.1.318.1.1.26.2.1.11DisplayStringread-onlymandatory
rPDU2IdentLongDescription
OBJECT-TYPE
The Rack PDU Long Description name
1.3.6.1.4.1.318.1.1.26.2.1.12DisplayStringread-onlymandatory
rPDU2IdentNMCSerialNumber
OBJECT-TYPE
The Rack PDU Network Management Card (NMC) serial number
1.3.6.1.4.1.318.1.1.26.2.1.13DisplayStringread-onlymandatory
rPDU2IndentAppBuildDate
OBJECT-TYPE
The Rack PDU Application build date
1.3.6.1.4.1.318.1.1.26.2.1.14DisplayStringread-onlymandatory
rPDU2IndentAOSBuildDate
OBJECT-TYPE
The Rack PDU AOS build date
1.3.6.1.4.1.318.1.1.26.2.1.15DisplayStringread-onlymandatory
rPDU2IndentBootMonBuildDate
OBJECT-TYPE
The Rack PDU Boot Monitor build date
1.3.6.1.4.1.318.1.1.26.2.1.16DisplayStringread-onlymandatory
rPDU2DeviceTableSize
OBJECT-TYPE
The total number of Rack PDUs
1.3.6.1.4.1.318.1.1.26.3INTEGERread-onlymandatory
rPDU2Device
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.4
rPDU2DeviceConfigTable
OBJECT-TYPE
A table of Rack PDU configuration data
1.3.6.1.4.1.318.1.1.26.4.1not-accessiblemandatory
rPDU2DeviceConfigEntry
OBJECT-TYPE
Configuration data from Rack PDU being queried
1.3.6.1.4.1.318.1.1.26.4.1.1not-accessiblemandatory
rPDU2DeviceConfigIndex
OBJECT-TYPE
The index to the Rack PDU table entry
1.3.6.1.4.1.318.1.1.26.4.1.1.1INTEGERread-onlymandatory
rPDU2DeviceConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.4.1.1.2INTEGERread-writemandatory
rPDU2DeviceConfigName
OBJECT-TYPE
A user-defined string identifying the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.1.1.3DisplayStringread-writemandatory
rPDU2DeviceConfigLocation
OBJECT-TYPE
A user-defined string identifying the location of the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.1.1.4DisplayStringread-writemandatory
rPDU2DeviceConfigDisplayOrientation
OBJECT-TYPE
Indicates the intended physical orientation of the display. displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation
1.3.6.1.4.1.318.1.1.26.4.1.1.5INTEGER {displayNormal(1), displayReverse(2)}read-writemandatory
rPDU2DeviceConfigColdstartDelay
OBJECT-TYPE
The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes).
1.3.6.1.4.1.318.1.1.26.4.1.1.6INTEGERread-writemandatory
rPDU2DeviceConfigLowLoadPowerThreshold
OBJECT-TYPE
User-defined low power draw alarm threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.1.1.7INTEGERread-writemandatory
rPDU2DeviceConfigNearOverloadPowerThreshold
OBJECT-TYPE
User-defined near power overload threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.1.1.8INTEGERread-writemandatory
rPDU2DeviceConfigOverloadPowerThreshold
OBJECT-TYPE
User-defined power overload threshold, measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.1.1.9INTEGERread-writemandatory
rPDU2DeviceConfigDevicePeakPowerReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of not supported (3). Attempts to set this OID in these models will fail.
1.3.6.1.4.1.318.1.1.26.4.1.1.10INTEGER {noOperation(1), reset(2), notSupported(3)}read-writemandatory
rPDU2DeviceConfigDeviceEnergyReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
1.3.6.1.4.1.318.1.1.26.4.1.1.11INTEGER {noOperation(1), reset(2), notSupported(3)}read-writemandatory
rPDU2DeviceConfigOutletsEnergyReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the all outlet energy meter values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
1.3.6.1.4.1.318.1.1.26.4.1.1.12INTEGER {noOperation(1), reset(2), notSupported(3)}read-writemandatory
rPDU2DeviceConfigOutletsPeakLoadReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the all outlet peak load values to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
1.3.6.1.4.1.318.1.1.26.4.1.1.13INTEGER {noOperation(1), reset(2), notSupported(3)}read-writemandatory
rPDU2DeviceConfigContact
OBJECT-TYPE
A user-defined string identifying the person to contact regarding the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.1.1.14DisplayStringread-writemandatory
rPDU2DevicePropertiesTable
OBJECT-TYPE
A table of Rack PDU properties
1.3.6.1.4.1.318.1.1.26.4.2not-accessiblemandatory
rPDU2DevicePropertiesEntry
OBJECT-TYPE
Properties of the Rack PDU being queried
1.3.6.1.4.1.318.1.1.26.4.2.1not-accessiblemandatory
rPDU2DevicePropertiesIndex
OBJECT-TYPE
The index to the Rack PDU properties table entry
1.3.6.1.4.1.318.1.1.26.4.2.1.1INTEGERread-onlymandatory
rPDU2DevicePropertiesModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.4.2.1.2INTEGERread-onlymandatory
rPDU2DevicePropertiesName
OBJECT-TYPE
A user-defined string identifying the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.3DisplayStringread-onlymandatory
rPDU2DevicePropertiesNumOutlets
OBJECT-TYPE
The number of outlets on the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.4INTEGERread-onlymandatory
rPDU2DevicePropertiesNumSwitchedOutlets
OBJECT-TYPE
The number of switched outlets on the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.5INTEGERread-onlymandatory
rPDU2DevicePropertiesNumMeteredOutlets
OBJECT-TYPE
The number of metered outlets on the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.6INTEGERread-onlymandatory
rPDU2DevicePropertiesNumPhases
OBJECT-TYPE
The number of phases present in the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.7INTEGERread-onlymandatory
rPDU2DevicePropertiesNumMeteredBanks
OBJECT-TYPE
The number of metered banks present in the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.8INTEGERread-onlymandatory
rPDU2DevicePropertiesMaxCurrentRating
OBJECT-TYPE
The maximum current rating, measured in Amps, for the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.9INTEGERread-onlymandatory
rPDU2DevicePropertiesOrientation
OBJECT-TYPE
Rack PDU orientation
1.3.6.1.4.1.318.1.1.26.4.2.1.10INTEGER {horizontal(1), vertical(2), verticalISXv2(3), verticalISXv3(4)}read-onlymandatory
rPDU2DevicePropertiesOutletLayout
OBJECT-TYPE
Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... or for single phase SKUs, all outlets 1-N seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: For AP8xxx SKU's Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9): Outlet layout does not affect any of the user interfaces for AP88XX SKUs. These SKUs may report seqNotApplicable(9) if there is not an exact outlet layout match available. seqPhToNPhToPhPhToN(10) indicates outlet layout as follows: Group 1:1-N, Group 2:1-2, Group 3:2-N.
1.3.6.1.4.1.318.1.1.26.4.2.1.11INTEGER {seqPhaseToNeutral(1), seqPhaseToPhase(2), seqPhToNeu21PhToPh(3), seqPhToPhGrouped(4), seqPhToNGrouped(5), seqPToN1516PToPGrouped(6), seqPhToPh2xGrouped(7), seqPhToN2xGrouped(8), seqNotApplicable(9), seqPhToNPhToPhPhToN(10)}read-onlymandatory
rPDU2DevicePropertiesMaxPhaseCurrentRating
OBJECT-TYPE
The maximum current rating, measured in Amps, for the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.12INTEGERread-onlymandatory
rPDU2DevicePropertiesDevicePowerRating
OBJECT-TYPE
The maximum power rating, measured in Watts, for the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.2.1.13INTEGERread-onlymandatory
rPDU2DeviceStatusTable
OBJECT-TYPE
A table of Rack PDU status information
1.3.6.1.4.1.318.1.1.26.4.3not-accessiblemandatory
rPDU2DeviceStatusEntry
OBJECT-TYPE
Status information from the Rack PDU being queried
1.3.6.1.4.1.318.1.1.26.4.3.1not-accessiblemandatory
rPDU2DeviceStatusIndex
OBJECT-TYPE
The index to the Rack PDU status table entry
1.3.6.1.4.1.318.1.1.26.4.3.1.1INTEGERread-onlymandatory
rPDU2DeviceStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.4.3.1.2INTEGERread-onlymandatory
rPDU2DeviceStatusName
OBJECT-TYPE
A user-defined string identifying the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.3.1.3DisplayStringread-onlymandatory
rPDU2DeviceStatusLoadState
OBJECT-TYPE
Indicates the present load status of the Rack PDU. Models that do not support this feature will respond to this OID with a value of notsupported (5).
1.3.6.1.4.1.318.1.1.26.4.3.1.4INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4), notsupported(5)}read-onlymandatory
rPDU2DeviceStatusPower
OBJECT-TYPE
The power consumption of the Rack PDU load in hundredths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.3.1.5INTEGERread-onlymandatory
rPDU2DeviceStatusPeakPower
OBJECT-TYPE
The peak power consumption of the Rack PDU load in hundredths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.3.1.6INTEGERread-onlymandatory
rPDU2DeviceStatusPeakPowerTimestamp
OBJECT-TYPE
Indicates the date and time that peak power consumption occurred. Models that do not support this feature will respond to this OID with string 'notsupported'.
1.3.6.1.4.1.318.1.1.26.4.3.1.7DisplayStringread-onlymandatory
rPDU2DeviceStatusPeakPowerStartTime
OBJECT-TYPE
Indicates the date and time of the last device peak power reset. Models that do not support this feature will respond to this OID with string 'notsupported'.
1.3.6.1.4.1.318.1.1.26.4.3.1.8DisplayStringread-onlymandatory
rPDU2DeviceStatusEnergy
OBJECT-TYPE
A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.3.1.9INTEGERread-onlymandatory
rPDU2DeviceStatusEnergyStartTime
OBJECT-TYPE
Indicates the date and time of the last device energy meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'.
1.3.6.1.4.1.318.1.1.26.4.3.1.10DisplayStringread-onlymandatory
rPDU2DeviceStatusCommandPending
OBJECT-TYPE
Indicates whether or not the device is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cycled to clear this condition.
1.3.6.1.4.1.318.1.1.26.4.3.1.11INTEGER {commandPending(1), noCommandPending(2), commandPendingUnknown(3)}read-onlymandatory
rPDU2DeviceStatusPowerSupplyAlarm
OBJECT-TYPE
Indicates a power supply alarm is active when value equals alarm (2)
1.3.6.1.4.1.318.1.1.26.4.3.1.12INTEGER {normal(1), alarm(2)}read-onlymandatory
rPDU2DeviceStatusPowerSupply1Status
OBJECT-TYPE
Indicates whether or not an alarm is active in Power Supply 1
1.3.6.1.4.1.318.1.1.26.4.3.1.13INTEGER {normal(1), alarm(2), notInstalled(3)}read-onlymandatory
rPDU2DeviceStatusPowerSupply2Status
OBJECT-TYPE
Indicates whether or not an alarm is active in Power Supply 2
1.3.6.1.4.1.318.1.1.26.4.3.1.14INTEGER {normal(1), alarm(2), notInstalled(3)}read-onlymandatory
rPDU2DeviceStatusOutletsEnergyStartTime
OBJECT-TYPE
Indicates the date and time of the last outlets energy meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'.
1.3.6.1.4.1.318.1.1.26.4.3.1.15DisplayStringread-onlymandatory
rPDU2DeviceStatusApparentPower
OBJECT-TYPE
The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA). Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.3.1.16INTEGERread-onlymandatory
rPDU2DeviceStatusPowerFactor
OBJECT-TYPE
The power factor of the Rack PDU load in hundredths. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.4.3.1.17INTEGERread-onlymandatory
rPDU2DeviceStatusNPSType
OBJECT-TYPE
The device NPS status: notNPS (1) indicates the Rack PDU is not in an NPS group. host (2) indicates the Rack PDU has been designated as a host in an NPS group. Only one Rack PDU in an NPS group is allowed to be the host. guest (3) indicates the Rack PDU has been designated as a guest in an NPS group.
1.3.6.1.4.1.318.1.1.26.4.3.1.18INTEGER {notNPS(1), host(2), guest(3)}read-onlymandatory
rPDU2DeviceControlTable
OBJECT-TYPE
A table of Rack PDU control data
1.3.6.1.4.1.318.1.1.26.4.4not-accessiblemandatory
rPDU2DeviceControlEntry
OBJECT-TYPE
Control data from Rack PDU being queried
1.3.6.1.4.1.318.1.1.26.4.4.1not-accessiblemandatory
rPDU2DeviceControlIndex
OBJECT-TYPE
The index to the Rack PDU control table entry
1.3.6.1.4.1.318.1.1.26.4.4.1.1INTEGERread-onlymandatory
rPDU2DeviceControlModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.4.4.1.2INTEGERread-onlymandatory
rPDU2DeviceControlName
OBJECT-TYPE
A user-defined string identifying the Rack PDU
1.3.6.1.4.1.318.1.1.26.4.4.1.3DisplayStringread-onlymandatory
rPDU2DeviceControlCommand
OBJECT-TYPE
Setting this OID to immediateAllOn (1) will turn all outlets on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime OID value. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will cause an immediateAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateAllOn command. Setting this OID to delayedAllReboot (5) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to noCommandAll (6) will have no effect. Setting this OID to delayedAllOff (7) will turn all outlets off as defined by each outlet's rPDU2OutletSwitchedConfigPowerOffTime OID value. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be cancelled. Getting this OID will return the noCommandAll (6) value.
1.3.6.1.4.1.318.1.1.26.4.4.1.4INTEGER {immediateAllOn(1), delayedAllOn(2), immediateAllOff(3), immediateAllReboot(4), delayedAllReboot(5), noCommandAll(6), delayedAllOff(7), cancelAllPendingCommands(8)}read-writemandatory
rPDU2PhaseTableSize
OBJECT-TYPE
The number of connected Rack PDU phases
1.3.6.1.4.1.318.1.1.26.5INTEGERread-onlymandatory
rPDU2Phase
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.6
rPDU2PhaseConfigTable
OBJECT-TYPE
A table of Rack PDU phase configuration data
1.3.6.1.4.1.318.1.1.26.6.1not-accessiblemandatory
rPDU2PhaseConfigEntry
OBJECT-TYPE
Configuration data from currently queried Rack PDU phase
1.3.6.1.4.1.318.1.1.26.6.1.1not-accessiblemandatory
rPDU2PhaseConfigIndex
OBJECT-TYPE
The index to the Rack PDU phase configuration table entry
1.3.6.1.4.1.318.1.1.26.6.1.1.1INTEGERread-onlymandatory
rPDU2PhaseConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.6.1.1.2INTEGERread-onlymandatory
rPDU2PhaseConfigNumber
OBJECT-TYPE
The numeric phase ID
1.3.6.1.4.1.318.1.1.26.6.1.1.3INTEGERread-onlymandatory
rPDU2PhaseConfigOverloadRestriction
OBJECT-TYPE
This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the rPDULoadConfigOverloadThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail.
1.3.6.1.4.1.318.1.1.26.6.1.1.4INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3), notSupported(4)}read-writemandatory
rPDU2PhaseConfigLowLoadCurrentThreshold
OBJECT-TYPE
User-defined low load phase current threshold in Amps
1.3.6.1.4.1.318.1.1.26.6.1.1.5INTEGERread-writemandatory
rPDU2PhaseConfigNearOverloadCurrentThreshold
OBJECT-TYPE
User-defined near phase overload warning threshold in Amps
1.3.6.1.4.1.318.1.1.26.6.1.1.6INTEGERread-writemandatory
rPDU2PhaseConfigOverloadCurrentThreshold
OBJECT-TYPE
User-defined phase overload current threshold in Amps
1.3.6.1.4.1.318.1.1.26.6.1.1.7INTEGERread-writemandatory
rPDU2PhaseConfigPhasePeakCurrentReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.26.6.1.1.8INTEGER {noOperation(1), reset(2)}read-writemandatory
rPDU2PhasePropertiesTable
OBJECT-TYPE
A table of Rack PDU phase properties
1.3.6.1.4.1.318.1.1.26.6.2not-accessiblemandatory
rPDU2PhasePropertiesEntry
OBJECT-TYPE
Properties of the currently queried Rack PDU phase
1.3.6.1.4.1.318.1.1.26.6.2.1not-accessiblemandatory
rPDU2PhasePropertiesIndex
OBJECT-TYPE
The index to the Rack PDU phase properties table entry
1.3.6.1.4.1.318.1.1.26.6.2.1.1INTEGERread-onlymandatory
rPDU2PhasePropertiesModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.6.2.1.2INTEGERread-onlymandatory
rPDU2PhasePropertiesNumber
OBJECT-TYPE
The numeric phase ID
1.3.6.1.4.1.318.1.1.26.6.2.1.3INTEGERread-onlymandatory
rPDU2PhaseStatusTable
OBJECT-TYPE
A table of Rack PDU phase status data
1.3.6.1.4.1.318.1.1.26.6.3not-accessiblemandatory
rPDU2PhaseStatusEntry
OBJECT-TYPE
Status data from currently queried Rack PDU phase
1.3.6.1.4.1.318.1.1.26.6.3.1not-accessiblemandatory
rPDU2PhaseStatusIndex
OBJECT-TYPE
The index to the Rack PDU phase status table entry
1.3.6.1.4.1.318.1.1.26.6.3.1.1INTEGERread-onlymandatory
rPDU2PhaseStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.6.3.1.2INTEGERread-onlymandatory
rPDU2PhaseStatusNumber
OBJECT-TYPE
The numeric phase ID
1.3.6.1.4.1.318.1.1.26.6.3.1.3INTEGERread-onlymandatory
rPDU2PhaseStatusLoadState
OBJECT-TYPE
Indicates the present load status of the Rack PDU phase being queried
1.3.6.1.4.1.318.1.1.26.6.3.1.4INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4)}read-onlymandatory
rPDU2PhaseStatusCurrent
OBJECT-TYPE
Indicates the current draw, in tenths of Amps, of the load on the Rack PDU phase being queried
1.3.6.1.4.1.318.1.1.26.6.3.1.5INTEGERread-onlymandatory
rPDU2PhaseStatusVoltage
OBJECT-TYPE
Indicates the Voltage, in Volts, of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.6.3.1.6INTEGERread-onlymandatory
rPDU2PhaseStatusPower
OBJECT-TYPE
Indicates the load power, in hundredths of kilowatts (kW), consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.6.3.1.7INTEGERread-onlymandatory
rPDU2PhaseStatusApparentPower
OBJECT-TYPE
Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA), consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.6.3.1.8INTEGERread-onlymandatory
rPDU2PhaseStatusPowerFactor
OBJECT-TYPE
Indicates the load power factor, in hundredths, of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.26.6.3.1.9INTEGERread-onlymandatory
rPDU2PhaseStatusPeakCurrent
OBJECT-TYPE
The peak current of the Rack PDU phase load in tenths of Amps
1.3.6.1.4.1.318.1.1.26.6.3.1.10INTEGERread-onlymandatory
rPDU2PhaseStatusPeakCurrentTimestamp
OBJECT-TYPE
Indicates the date and time that the peak current occurred
1.3.6.1.4.1.318.1.1.26.6.3.1.11DisplayStringread-onlymandatory
rPDU2PhaseStatusPeakCurrentStartTime
OBJECT-TYPE
Indicates the date and time of the last phase peak current reset
1.3.6.1.4.1.318.1.1.26.6.3.1.12DisplayStringread-onlymandatory
rPDU2BankTableSize
OBJECT-TYPE
The number of connected Rack PDU banks
1.3.6.1.4.1.318.1.1.26.7INTEGERread-onlymandatory
rPDU2Bank
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.8
rPDU2BankConfigTable
OBJECT-TYPE
A table of Rack PDU bank configuration data
1.3.6.1.4.1.318.1.1.26.8.1not-accessiblemandatory
rPDU2BankConfigEntry
OBJECT-TYPE
Configuration data from currently queried Rack PDU bank
1.3.6.1.4.1.318.1.1.26.8.1.1not-accessiblemandatory
rPDU2BankConfigIndex
OBJECT-TYPE
The index to the Rack PDU bank configuration table entry
1.3.6.1.4.1.318.1.1.26.8.1.1.1INTEGERread-onlymandatory
rPDU2BankConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.8.1.1.2INTEGERread-onlymandatory
rPDU2BankConfigNumber
OBJECT-TYPE
The numeric bank ID
1.3.6.1.4.1.318.1.1.26.8.1.1.3INTEGERread-onlymandatory
rPDU2BankConfigOverloadRestriction
OBJECT-TYPE
This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the rPDU2BankConfigNearOverloadCurrentThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the rPDU2BankConfigOverloadCurrentThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (4). Attempts to set this OID in these models will fail.
1.3.6.1.4.1.318.1.1.26.8.1.1.4INTEGER {alwaysAllowTurnON(1), restrictOnNearOverload(2), restrictOnOverload(3), notSupported(4)}read-writemandatory
rPDU2BankConfigLowLoadCurrentThreshold
OBJECT-TYPE
User-defined low load bank current threshold in Amps
1.3.6.1.4.1.318.1.1.26.8.1.1.5INTEGERread-writemandatory
rPDU2BankConfigNearOverloadCurrentThreshold
OBJECT-TYPE
User-defined near bank overload current warning threshold in Amps
1.3.6.1.4.1.318.1.1.26.8.1.1.6INTEGERread-writemandatory
rPDU2BankConfigOverloadCurrentThreshold
OBJECT-TYPE
User-defined bank overload current threshold in Amps
1.3.6.1.4.1.318.1.1.26.8.1.1.7INTEGERread-writemandatory
rPDU2BankConfigBankPeakCurrentReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.26.8.1.1.8INTEGER {noOperation(1), reset(2)}read-writemandatory
rPDU2BankPropertiesTable
OBJECT-TYPE
A table of Rack PDU bank properties
1.3.6.1.4.1.318.1.1.26.8.2not-accessiblemandatory
rPDU2BankPropertiesEntry
OBJECT-TYPE
Properties of the currently queried Rack PDU bank
1.3.6.1.4.1.318.1.1.26.8.2.1not-accessiblemandatory
rPDU2BankPropertiesIndex
OBJECT-TYPE
The index to the Rack PDU bank properties table entry
1.3.6.1.4.1.318.1.1.26.8.2.1.1INTEGERread-onlymandatory
rPDU2BankPropertiesModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.8.2.1.2INTEGERread-onlymandatory
rPDU2BankPropertiesNumber
OBJECT-TYPE
The numeric bank ID
1.3.6.1.4.1.318.1.1.26.8.2.1.3INTEGERread-onlymandatory
rPDU2BankPropertiesPhaseLayout
OBJECT-TYPE
This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that bank outlets are wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that bank outlets are wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that bank outlets are wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that bank outlets are wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that bank outlets are wired from Phase 3 to Phase 1.
1.3.6.1.4.1.318.1.1.26.8.2.1.4Rpdu2OutletPhaseLayoutTyperead-onlymandatory
rPDU2BankPropertiesBreakerRating
OBJECT-TYPE
If bank circuit breakers are present on the device, this OID will return the rating of the breaker in Amps.
1.3.6.1.4.1.318.1.1.26.8.2.1.5INTEGERread-onlymandatory
rPDU2BankStatusTable
OBJECT-TYPE
A table of Rack PDU bank status data
1.3.6.1.4.1.318.1.1.26.8.3not-accessiblemandatory
rPDU2BankStatusEntry
OBJECT-TYPE
Status data from currently queried Rack PDU bank
1.3.6.1.4.1.318.1.1.26.8.3.1not-accessiblemandatory
rPDU2BankStatusIndex
OBJECT-TYPE
The index to the Rack PDU bank status table entry
1.3.6.1.4.1.318.1.1.26.8.3.1.1INTEGERread-onlymandatory
rPDU2BankStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.8.3.1.2INTEGERread-onlymandatory
rPDU2BankStatusNumber
OBJECT-TYPE
The numeric bank ID
1.3.6.1.4.1.318.1.1.26.8.3.1.3INTEGERread-onlymandatory
rPDU2BankStatusLoadState
OBJECT-TYPE
Indicates the present load status of the Rack PDU bank being queried
1.3.6.1.4.1.318.1.1.26.8.3.1.4INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4)}read-onlymandatory
rPDU2BankStatusCurrent
OBJECT-TYPE
Indicates the current draw, in tenths of Amps, of the load on the Rack PDU bank being queried
1.3.6.1.4.1.318.1.1.26.8.3.1.5INTEGERread-onlymandatory
rPDU2BankStatusPeakCurrent
OBJECT-TYPE
The peak current of the Rack PDU bank load in tenths of Amps
1.3.6.1.4.1.318.1.1.26.8.3.1.6INTEGERread-onlymandatory
rPDU2BankStatusPeakCurrentTimestamp
OBJECT-TYPE
Indicates the date and time the bank peak current occurred
1.3.6.1.4.1.318.1.1.26.8.3.1.7DisplayStringread-onlymandatory
rPDU2BankStatusPeakCurrentStartTime
OBJECT-TYPE
Indicates the date and time of the last bank peak current reset
1.3.6.1.4.1.318.1.1.26.8.3.1.8DisplayStringread-onlymandatory
rPDU2Outlet
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.9
rPDU2OutletSwitchedTableSize
OBJECT-TYPE
The number of switched outlets on connected Rack PDUs
1.3.6.1.4.1.318.1.1.26.9.1INTEGERread-onlymandatory
rPDU2OutletSwitched
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.9.2
rPDU2OutletSwitchedConfigTable
OBJECT-TYPE
A table of Rack PDU switched outlet configuration data
1.3.6.1.4.1.318.1.1.26.9.2.1not-accessiblemandatory
rPDU2OutletSwitchedConfigEntry
OBJECT-TYPE
Configuration data from currently queried Rack PDU switched outlet
1.3.6.1.4.1.318.1.1.26.9.2.1.1not-accessiblemandatory
rPDU2OutletSwitchedConfigIndex
OBJECT-TYPE
The index to the Rack PDU switched outlet configuration table entry
1.3.6.1.4.1.318.1.1.26.9.2.1.1.1INTEGERread-onlymandatory
rPDU2OutletSwitchedConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.2.1.1.2INTEGERread-onlymandatory
rPDU2OutletSwitchedConfigName
OBJECT-TYPE
The user-defined switched outlet ID string
1.3.6.1.4.1.318.1.1.26.9.2.1.1.3DisplayStringread-writemandatory
rPDU2OutletSwitchedConfigNumber
OBJECT-TYPE
The numeric switched outlet ID
1.3.6.1.4.1.318.1.1.26.9.2.1.1.4INTEGERread-onlymandatory
rPDU2OutletSwitchedConfigPowerOnTime
OBJECT-TYPE
The amount of delay, in seconds, between when power is provided to the Rack PDU and when this switched outlet starts providing power. Range -1...300 where -1 = Never power on, 0 = immediate power on, and 1-300 = seconds to delay.
1.3.6.1.4.1.318.1.1.26.9.2.1.1.5INTEGERread-writemandatory
rPDU2OutletSwitchedConfigPowerOffTime
OBJECT-TYPE
The amount of time, in seconds, this outlet will delay powering off. Range -1...360 where -1 = Never power off, 0 = immediate power off, and 1-360 = seconds to delay.
1.3.6.1.4.1.318.1.1.26.9.2.1.1.6INTEGERread-writemandatory
rPDU2OutletSwitchedConfigRebootDuration
OBJECT-TYPE
After turning power off during a reboot sequence, the amount of time to wait before turning power to this outlet back on. Range 5-60 seconds delay.
1.3.6.1.4.1.318.1.1.26.9.2.1.1.7INTEGERread-writemandatory
rPDU2OutletSwitchedPropertiesTable
OBJECT-TYPE
A table of Rack PDU switched outlet properties
1.3.6.1.4.1.318.1.1.26.9.2.2not-accessiblemandatory
rPDU2OutletSwitchedPropertiesEntry
OBJECT-TYPE
Properties of the currently queried Rack PDU switched outlet
1.3.6.1.4.1.318.1.1.26.9.2.2.1not-accessiblemandatory
rPDU2OutletSwitchedPropertiesIndex
OBJECT-TYPE
The index to the Rack PDU switched outlet properties table entry
1.3.6.1.4.1.318.1.1.26.9.2.2.1.1INTEGERread-onlymandatory
rPDU2OutletSwitchedPropertiesModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.2.2.1.2INTEGERread-onlymandatory
rPDU2OutletSwitchedPropertiesName
OBJECT-TYPE
The user-defined switched outlet ID string
1.3.6.1.4.1.318.1.1.26.9.2.2.1.3DisplayStringread-onlymandatory
rPDU2OutletSwitchedPropertiesNumber
OBJECT-TYPE
The numeric switched outlet ID
1.3.6.1.4.1.318.1.1.26.9.2.2.1.4INTEGERread-onlymandatory
rPDU2OutletSwitchedPropertiesPhaseLayout
OBJECT-TYPE
This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1.
1.3.6.1.4.1.318.1.1.26.9.2.2.1.5Rpdu2OutletPhaseLayoutTyperead-onlymandatory
rPDU2OutletSwitchedPropertiesBank
OBJECT-TYPE
The numeric bank ID
1.3.6.1.4.1.318.1.1.26.9.2.2.1.6INTEGERread-onlymandatory
rPDU2OutletSwitchedStatusTable
OBJECT-TYPE
A table of Rack PDU switched outlet status information
1.3.6.1.4.1.318.1.1.26.9.2.3not-accessiblemandatory
rPDU2OutletSwitchedStatusEntry
OBJECT-TYPE
Status information for currently queried Rack PDU switched outlet
1.3.6.1.4.1.318.1.1.26.9.2.3.1not-accessiblemandatory
rPDU2OutletSwitchedStatusIndex
OBJECT-TYPE
The index to the Rack PDU switched outlet status information table entry
1.3.6.1.4.1.318.1.1.26.9.2.3.1.1INTEGERread-onlymandatory
rPDU2OutletSwitchedStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.2.3.1.2INTEGERread-onlymandatory
rPDU2OutletSwitchedStatusName
OBJECT-TYPE
The user-defined switched outlet ID string
1.3.6.1.4.1.318.1.1.26.9.2.3.1.3DisplayStringread-onlymandatory
rPDU2OutletSwitchedStatusNumber
OBJECT-TYPE
The numeric switched outlet ID
1.3.6.1.4.1.318.1.1.26.9.2.3.1.4INTEGERread-onlymandatory
rPDU2OutletSwitchedStatusState
OBJECT-TYPE
Indicates the present switch state of the Rack PDU switched outlet being queried
1.3.6.1.4.1.318.1.1.26.9.2.3.1.5INTEGER {off(1), on(2)}read-onlymandatory
rPDU2OutletSwitchedStatusCommandPending
OBJECT-TYPE
Indicates whether or not the device is processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cycled to clear this condition.
1.3.6.1.4.1.318.1.1.26.9.2.3.1.6INTEGER {commandPending(1), noCommandPending(2), commandPendingUnknown(3)}read-onlymandatory
rPDU2OutletSwitchedControlTable
OBJECT-TYPE
A table of Rack PDU switched outlet control data
1.3.6.1.4.1.318.1.1.26.9.2.4not-accessiblemandatory
rPDU2OutletSwitchedControlEntry
OBJECT-TYPE
Control data for currently queried Rack PDU switched outlet
1.3.6.1.4.1.318.1.1.26.9.2.4.1not-accessiblemandatory
rPDU2OutletSwitchedControlIndex
OBJECT-TYPE
The index to the Rack PDU switched outlet control data table entry
1.3.6.1.4.1.318.1.1.26.9.2.4.1.1INTEGERread-onlymandatory
rPDU2OutletSwitchedControlModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.2.4.1.2INTEGERread-onlymandatory
rPDU2OutletSwitchedControlName
OBJECT-TYPE
The user-defined switched outlet ID string
1.3.6.1.4.1.318.1.1.26.9.2.4.1.3DisplayStringread-onlymandatory
rPDU2OutletSwitchedControlNumber
OBJECT-TYPE
The numeric switched outlet ID
1.3.6.1.4.1.318.1.1.26.9.2.4.1.4INTEGERread-onlymandatory
rPDU2OutletSwitchedControlCommand
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will cause the Switched Rack PDU to perform an immediateOff command, wait the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateOn command. Setting this variable to delayedOn (5) will turn the outlet on after the rPDU2OutletSwitchedConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (6) will turn the outlet off after the rPDU2OutletSwitchedConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (7) will cause the Switched Rack PDU to perform a delayedOff command, wait the rPDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (8) will cause any pending command to this outlet to be cancelled.
1.3.6.1.4.1.318.1.1.26.9.2.4.1.5INTEGER {immediateOn(1), immediateOff(2), immediateReboot(3), outletUnknown(4), delayedOn(5), delayedOff(6), delayedReboot(7), cancelPendingCommand(8)}read-writemandatory
rPDU2OutletMeteredTableSize
OBJECT-TYPE
The number of metered outlets on connect Rack PDUs
1.3.6.1.4.1.318.1.1.26.9.3INTEGERread-onlymandatory
rPDU2OutletMetered
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.9.4
rPDU2OutletMeteredConfigTable
OBJECT-TYPE
A table of Rack PDU metered outlet configuration data
1.3.6.1.4.1.318.1.1.26.9.4.1not-accessiblemandatory
rPDU2OutletMeteredConfigEntry
OBJECT-TYPE
Configuration data from currently queried Rack PDU metered outlet
1.3.6.1.4.1.318.1.1.26.9.4.1.1not-accessiblemandatory
rPDU2OutletMeteredConfigIndex
OBJECT-TYPE
The index to the Rack PDU metered outlet configuration table entry
1.3.6.1.4.1.318.1.1.26.9.4.1.1.1INTEGERread-onlymandatory
rPDU2OutletMeteredConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.4.1.1.2INTEGERread-onlymandatory
rPDU2OutletMeteredConfigName
OBJECT-TYPE
The user-defined metered outlet ID string
1.3.6.1.4.1.318.1.1.26.9.4.1.1.3DisplayStringread-writemandatory
rPDU2OutletMeteredConfigNumber
OBJECT-TYPE
The numeric switched outlet ID
1.3.6.1.4.1.318.1.1.26.9.4.1.1.4INTEGERread-onlymandatory
rPDU2OutletMeteredConfigLowLoadCurrentThreshold
OBJECT-TYPE
User-defined low load outlet current threshold in Watts
1.3.6.1.4.1.318.1.1.26.9.4.1.1.5INTEGERread-writemandatory
rPDU2OutletMeteredConfigNearOverloadCurrentThreshold
OBJECT-TYPE
User-defined near outlet overload warning threshold in Watts
1.3.6.1.4.1.318.1.1.26.9.4.1.1.6INTEGERread-writemandatory
rPDU2OutletMeteredConfigOverloadCurrentThreshold
OBJECT-TYPE
User-defined outlet overload current threshold in Watts
1.3.6.1.4.1.318.1.1.26.9.4.1.1.7INTEGERread-writemandatory
rPDU2OutletMeteredPropertiesTable
OBJECT-TYPE
A table of Rack PDU metered outlet properties
1.3.6.1.4.1.318.1.1.26.9.4.2not-accessiblemandatory
rPDU2OutletMeteredPropertiesEntry
OBJECT-TYPE
Properties of currently queried Rack PDU metered outlet
1.3.6.1.4.1.318.1.1.26.9.4.2.1not-accessiblemandatory
rPDU2OutletMeteredPropertiesIndex
OBJECT-TYPE
The index to the Rack PDU metered properties table entry
1.3.6.1.4.1.318.1.1.26.9.4.2.1.1INTEGERread-onlymandatory
rPDU2OutletMeteredPropertiesModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.4.2.1.2INTEGERread-onlymandatory
rPDU2OutletMeteredPropertiesName
OBJECT-TYPE
The user-defined metered outlet ID string
1.3.6.1.4.1.318.1.1.26.9.4.2.1.3DisplayStringread-onlymandatory
rPDU2OutletMeteredPropertiesNumber
OBJECT-TYPE
The numeric metered outlet ID
1.3.6.1.4.1.318.1.1.26.9.4.2.1.4INTEGERread-onlymandatory
rPDU2OutletMeteredPropertiesLayout
OBJECT-TYPE
This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1.
1.3.6.1.4.1.318.1.1.26.9.4.2.1.5Rpdu2OutletPhaseLayoutTyperead-onlymandatory
rPDU2OutletMeteredPropertiesPowerRating
OBJECT-TYPE
Maximum power rating of Rack PDU metered outlet
1.3.6.1.4.1.318.1.1.26.9.4.2.1.6INTEGERread-onlymandatory
rPDU2OutletMeteredPropertiesBank
OBJECT-TYPE
This outlet's numeric bank ID
1.3.6.1.4.1.318.1.1.26.9.4.2.1.7INTEGERread-onlymandatory
rPDU2OutletMeteredStatusTable
OBJECT-TYPE
A table of Rack PDU metered outlet status data
1.3.6.1.4.1.318.1.1.26.9.4.3not-accessiblemandatory
rPDU2OutletMeteredStatusEntry
OBJECT-TYPE
Status data from currently queried Rack PDU metered outlet
1.3.6.1.4.1.318.1.1.26.9.4.3.1not-accessiblemandatory
rPDU2OutletMeteredStatusIndex
OBJECT-TYPE
The index to the Rack PDU metered status table entry
1.3.6.1.4.1.318.1.1.26.9.4.3.1.1INTEGERread-onlymandatory
rPDU2OutletMeteredStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.9.4.3.1.2INTEGERread-onlymandatory
rPDU2OutletMeteredStatusName
OBJECT-TYPE
The user-defined metered outlet ID string
1.3.6.1.4.1.318.1.1.26.9.4.3.1.3DisplayStringread-onlymandatory
rPDU2OutletMeteredStatusNumber
OBJECT-TYPE
The numeric metered outlet ID
1.3.6.1.4.1.318.1.1.26.9.4.3.1.4INTEGERread-onlymandatory
rPDU2OutletMeteredStatusState
OBJECT-TYPE
Indicates the present load status of the Rack PDU metered outlet being queried
1.3.6.1.4.1.318.1.1.26.9.4.3.1.5INTEGER {lowLoad(1), normal(2), nearOverload(3), overload(4)}read-onlymandatory
rPDU2OutletMeteredStatusCurrent
OBJECT-TYPE
Indicates the current draw, in tenths of Amps, of the load on the Rack PDU outlet being queried
1.3.6.1.4.1.318.1.1.26.9.4.3.1.6INTEGERread-onlymandatory
rPDU2OutletMeteredStatusPower
OBJECT-TYPE
Indicates the power draw of the load on the Rack PDU outlet being queried
1.3.6.1.4.1.318.1.1.26.9.4.3.1.7INTEGERread-onlymandatory
rPDU2OutletMeteredStatusPeakPower
OBJECT-TYPE
Indicates the peak power load draw on the Rack PDU outlet being queried
1.3.6.1.4.1.318.1.1.26.9.4.3.1.8INTEGERread-onlymandatory
rPDU2OutletMeteredStatusPeakPowerTimestamp
OBJECT-TYPE
Indicates the date and time that this metered outlet's peak power consumption occurred
1.3.6.1.4.1.318.1.1.26.9.4.3.1.9DisplayStringread-onlymandatory
rPDU2OutletMeteredStatusPeakPowerStartTime
OBJECT-TYPE
Indicates the start date and time that this metered outlet began recording peak power observations
1.3.6.1.4.1.318.1.1.26.9.4.3.1.10DisplayStringread-onlymandatory
rPDU2OutletMeteredStatusEnergy
OBJECT-TYPE
A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours
1.3.6.1.4.1.318.1.1.26.9.4.3.1.11INTEGERread-onlymandatory
rPDU2OutletMeteredStatusReceptacleType
OBJECT-TYPE
Indicates receptacle type for the outlet.
1.3.6.1.4.1.318.1.1.26.9.4.3.1.12DisplayStringread-onlymandatory
rPDU2Sensor
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.10
rPDU2SensorTempHumidityTableSize
OBJECT-TYPE
The number of connected temperature-humidity sensors
1.3.6.1.4.1.318.1.1.26.10.1INTEGERread-onlymandatory
rPDU2SensorTempHumidity
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.10.2
rPDU2SensorTempHumidityConfigTable
OBJECT-TYPE
A table of temperature-humidity sensor configuration data
1.3.6.1.4.1.318.1.1.26.10.2.1not-accessiblemandatory
rPDU2SensorTempHumidityConfigEntry
OBJECT-TYPE
Configuration data from temperature-humidity sensor being queried
1.3.6.1.4.1.318.1.1.26.10.2.1.1not-accessiblemandatory
rPDU2SensorTempHumidityConfigIndex
OBJECT-TYPE
The index to the temperature-humidity sensor configuration data table entry
1.3.6.1.4.1.318.1.1.26.10.2.1.1.1INTEGERread-onlymandatory
rPDU2SensorTempHumidityConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.10.2.1.1.2INTEGERread-onlymandatory
rPDU2SensorTempHumidityConfigName
OBJECT-TYPE
The user-defined temperature-humidity sensor ID string
1.3.6.1.4.1.318.1.1.26.10.2.1.1.3DisplayStringread-writemandatory
rPDU2SensorTempHumidityConfigNumber
OBJECT-TYPE
The temperature-humidity sensor numeric ID
1.3.6.1.4.1.318.1.1.26.10.2.1.1.4INTEGERread-onlymandatory
rPDU2SensorTempHumidityConfigTemperatureAlarmEnable
OBJECT-TYPE
Setting this OID enables or disables generation of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.5INTEGER {disabled(1), enabled(2)}read-writemandatory
rPDU2SensorTempHumidityConfigHumidityAlarmEnable
OBJECT-TYPE
Setting this OID enables or disables generation of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
rPDU2SensorTempHumidityConfigTempMaxThreshF
OBJECT-TYPE
Sensor maximum temperature alarm threshold in Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshF will result in an error.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.7INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigTempHighThreshF
OBJECT-TYPE
Sensor high temperature warning alarm threshold in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshF will result in an error.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.8INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigTempHysteresisF
OBJECT-TYPE
Sensor temperature hysteresis setting in Fahrenheit
1.3.6.1.4.1.318.1.1.26.10.2.1.1.9INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigTempMaxThreshC
OBJECT-TYPE
Sensor maximum temperature alarm threshold in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshC will result in an error.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.10INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigTempHighThreshC
OBJECT-TYPE
Sensor high temperature warning alarm threshold in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshC will result in an error.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.11INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigTempHysteresisC
OBJECT-TYPE
Sensor temperature hysteresis setting in Celsius
1.3.6.1.4.1.318.1.1.26.10.2.1.1.12INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigHumidityLowThresh
OBJECT-TYPE
Sensor low humidity warning alarm threshold in percent relative humidity. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigHumidityMinThresh will result in an error. Must be between 15% and 90%
1.3.6.1.4.1.318.1.1.26.10.2.1.1.13INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigHumidityMinThresh
OBJECT-TYPE
Sensor minimum humidity alarm threshold in percent relative humidity. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigHumidityLowThresh will result in an error. Must be between 15% and 90%
1.3.6.1.4.1.318.1.1.26.10.2.1.1.14INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigHumidityHysteresis
OBJECT-TYPE
Sensor humidity hysteresis setting in percent relative humidity
1.3.6.1.4.1.318.1.1.26.10.2.1.1.15INTEGERread-writemandatory
rPDU2SensorTempHumidityConfigTempPeakReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the existing peak temperature to be replaced by the present temperature reading. Getting this OID will do nothing and return the noOperation(1) value.
1.3.6.1.4.1.318.1.1.26.10.2.1.1.16INTEGER {noOperation(1), reset(2)}read-writemandatory
rPDU2SensorTempHumidityStatusTable
OBJECT-TYPE
A table of temperature-humidity sensor status data
1.3.6.1.4.1.318.1.1.26.10.2.2not-accessiblemandatory
rPDU2SensorTempHumidityStatusEntry
OBJECT-TYPE
Status information from temperature-humidity sensor being queried
1.3.6.1.4.1.318.1.1.26.10.2.2.1not-accessiblemandatory
rPDU2SensorTempHumidityStatusIndex
OBJECT-TYPE
The index to the temperature-humidity status data table entry
1.3.6.1.4.1.318.1.1.26.10.2.2.1.1INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.10.2.2.1.2INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusName
OBJECT-TYPE
The user-defined temperature-humidity sensor ID string
1.3.6.1.4.1.318.1.1.26.10.2.2.1.3DisplayStringread-onlymandatory
rPDU2SensorTempHumidityStatusNumber
OBJECT-TYPE
The temperature-humidity sensor numeric ID
1.3.6.1.4.1.318.1.1.26.10.2.2.1.4INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusType
OBJECT-TYPE
The type of the sensor
1.3.6.1.4.1.318.1.1.26.10.2.2.1.5INTEGER {temperatureOnly(1), temperatureHumidity(2), commsLost(3), notInstalled(4)}read-onlymandatory
rPDU2SensorTempHumidityStatusCommStatus
OBJECT-TYPE
The communications status of the sensor
1.3.6.1.4.1.318.1.1.26.10.2.2.1.6INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
rPDU2SensorTempHumidityStatusTempF
OBJECT-TYPE
Sensor temperature reading in tenths of degrees Fahrenheit
1.3.6.1.4.1.318.1.1.26.10.2.2.1.7INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusTempC
OBJECT-TYPE
Sensor temperature reading in tenths of degrees Celsius
1.3.6.1.4.1.318.1.1.26.10.2.2.1.8INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusTempStatus
OBJECT-TYPE
This OID reports the current state of the temperature probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured temperature lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured temperature lies below the low threshold. A normal (4) response indicates that the probe is present and its measured temperature lies within all temperature thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a temperature above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a temperature above the max threshold.
1.3.6.1.4.1.318.1.1.26.10.2.2.1.9INTEGER {notPresent(1), belowMin(2), belowLow(3), normal(4), aboveHigh(5), aboveMax(6)}read-onlymandatory
rPDU2SensorTempHumidityStatusRelativeHumidity
OBJECT-TYPE
Sensor humidity reading in percent relative humidity
1.3.6.1.4.1.318.1.1.26.10.2.2.1.10INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusHumidityStatus
OBJECT-TYPE
This OID reports the current state of the humidity probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidity lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured humidity lies below the low threshold. A normal (4) response indicates that the probe is present and its measured humidity lies within all humidity thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a humidity above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a humidity above the max threshold.
1.3.6.1.4.1.318.1.1.26.10.2.2.1.11INTEGER {notPresent(1), belowMin(2), belowLow(3), normal(4), aboveHigh(5), aboveMax(6)}read-onlymandatory
rPDU2SensorTempHumidityStatusTempPeakF
OBJECT-TYPE
Sensor peak temperature in tenths of degrees Fahrenheit
1.3.6.1.4.1.318.1.1.26.10.2.2.1.12INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusTempPeakC
OBJECT-TYPE
Sensor peak temperature in tenths of degrees Celsius
1.3.6.1.4.1.318.1.1.26.10.2.2.1.13INTEGERread-onlymandatory
rPDU2SensorTempHumidityStatusTempPeakTimestamp
OBJECT-TYPE
Indicates the date and time that the peak temperature occurred
1.3.6.1.4.1.318.1.1.26.10.2.2.1.14DisplayStringread-onlymandatory
rPDU2SensorTempHumidityStatusTempPeakStartTime
OBJECT-TYPE
Indicates the date and time of the last temperature peak reset
1.3.6.1.4.1.318.1.1.26.10.2.2.1.15DisplayStringread-onlymandatory
rPDU2SensorDiscreteTableSize
OBJECT-TYPE
The number of connected discrete sensors
1.3.6.1.4.1.318.1.1.26.10.3INTEGERread-onlymandatory
rPDU2SensorDiscrete
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.10.4
rPDU2SensorDiscreteConfigTable
OBJECT-TYPE
A table of discrete sensor configuration data
1.3.6.1.4.1.318.1.1.26.10.4.1not-accessiblemandatory
rPDU2SensorDiscreteConfigEntry
OBJECT-TYPE
Configuration data from discreste sensor being queried
1.3.6.1.4.1.318.1.1.26.10.4.1.1not-accessiblemandatory
rPDU2SensorDiscreteConfigIndex
OBJECT-TYPE
The index to the discrete sensor configuration data table entry
1.3.6.1.4.1.318.1.1.26.10.4.1.1.1INTEGERread-onlymandatory
rPDU2SensorDiscreteConfigModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.10.4.1.1.2INTEGERread-onlymandatory
rPDU2SensorDiscreteConfigName
OBJECT-TYPE
The user-defined discrete sensor ID string
1.3.6.1.4.1.318.1.1.26.10.4.1.1.3DisplayStringread-writemandatory
rPDU2SensorDiscreteConfigNumber
OBJECT-TYPE
The discrete sensor numeric ID
1.3.6.1.4.1.318.1.1.26.10.4.1.1.4INTEGERread-onlymandatory
rPDU2SensorDiscreteConfigNormalState
OBJECT-TYPE
Indicates the normal state of the discrete input contact
1.3.6.1.4.1.318.1.1.26.10.4.1.1.5INTEGER {normallyOpen(1), normallyClosed(2)}read-writemandatory
rPDU2SensorDiscreteConfigAbnormalSeverity
OBJECT-TYPE
Indicates the severity of alarm triggered by abnormal discrete input contact state
1.3.6.1.4.1.318.1.1.26.10.4.1.1.6INTEGER {informational(1), warning(2), critical(3)}read-writemandatory
rPDU2SensorDiscreteStatusTable
OBJECT-TYPE
A table of discrete sensor status data
1.3.6.1.4.1.318.1.1.26.10.4.2not-accessiblemandatory
rPDU2SensorDiscreteStatusEntry
OBJECT-TYPE
Status information from discrete sensor being queried
1.3.6.1.4.1.318.1.1.26.10.4.2.1not-accessiblemandatory
rPDU2SensorDiscreteStatusIndex
OBJECT-TYPE
The index to the discrete sensor status data table entry
1.3.6.1.4.1.318.1.1.26.10.4.2.1.1INTEGERread-onlymandatory
rPDU2SensorDiscreteStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.10.4.2.1.2INTEGERread-onlymandatory
rPDU2SensorDiscreteStatusName
OBJECT-TYPE
The user-defined discrete sensor ID string
1.3.6.1.4.1.318.1.1.26.10.4.2.1.3DisplayStringread-onlymandatory
rPDU2SensorDiscreteStatusNumber
OBJECT-TYPE
The discrete sensor numeric ID
1.3.6.1.4.1.318.1.1.26.10.4.2.1.4INTEGERread-onlymandatory
rPDU2SensorDiscreteStatusType
OBJECT-TYPE
The type of discrete sensor currently being queried
1.3.6.1.4.1.318.1.1.26.10.4.2.1.5INTEGER {notConnected(1), doorContactSensor(2), smokeSensor(3), motionDetector(4), vibrationSensor(5), dryContactSensor(6), spotLeakSensor(7)}read-onlymandatory
rPDU2SensorDiscreteStatusCommStatus
OBJECT-TYPE
The communications status of the sensor
1.3.6.1.4.1.318.1.1.26.10.4.2.1.6INTEGER {notInstalled(1), commsOK(2), commsLost(3)}read-onlymandatory
rPDU2SensorDiscreteStatusCurrentState
OBJECT-TYPE
The current open/close state of the discrete sensor
1.3.6.1.4.1.318.1.1.26.10.4.2.1.7INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
rPDU2SensorDiscreteStatusAlarmState
OBJECT-TYPE
Indicates alarm status of discrete sensor input
1.3.6.1.4.1.318.1.1.26.10.4.2.1.8INTEGER {normal(1), alarm(2)}read-onlymandatory
rPDU2Group
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.11
rPDU2GroupNumberOfDevices
OBJECT-TYPE
Getting this OID will return the number of Rack PDU devices contributing to the Network Port Sharing (NPS) group power and energy values. Queries to guest units in an NPS group are not applicable and will return 0.
1.3.6.1.4.1.318.1.1.26.11.1INTEGERread-onlymandatory
rPDU2GroupTotalPower
OBJECT-TYPE
Getting this OID will return the total power consumption of the Rack PDU Network Port Sharing (NPS) group devices in hundredths of kilowatts. Queries to guest units in an NPS group are not applicable and will return 0.
1.3.6.1.4.1.318.1.1.26.11.2INTEGERread-onlymandatory
rPDU2GroupTotalEnergy
OBJECT-TYPE
Getting this OID will return the total energy consumption of the Rack PDU Network Port Sharing (NPS) group devices in tenths of kilowatt-hours. To reset the energy meters for each of the Rack PDU devices that contribute to this value, see the rPDU2GroupEnergyReset OID. To view the start time for each of the Rack PDU device energy meters that contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID. Queries to guest units in an NPS group are not applicable and will return 0.
1.3.6.1.4.1.318.1.1.26.11.3INTEGERread-onlymandatory
rPDU2GroupEnergyReset
OBJECT-TYPE
Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU Network Port Sharing (NPS) group to be reset to zero. Each device in the Rack PDU group will also have its corresponding rPDU2DeviceStatusEnergyStartTime OID value updated. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature, as well as guest units in an NPS group, will respond to this OID with a value of notSupported (3). Attempts to set this OID in these units will fail.
1.3.6.1.4.1.318.1.1.26.11.4INTEGER {noOperation(1), reset(2), notSupported(3)}read-writemandatory
rPDU2PhaseToPhaseStatusTableSize
OBJECT-TYPE
The number of connected Rack PDU banks
1.3.6.1.4.1.318.1.1.26.12INTEGERread-onlymandatory
rPDU2PhaseToPhase
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.26.13
rPDU2PhaseToPhaseStatusTable
OBJECT-TYPE
A table of Rack PDU phase to phase status data. This table is only applicable to SKUs that have phase to phase outputs.
1.3.6.1.4.1.318.1.1.26.13.1not-accessiblemandatory
rPDU2PhaseToPhaseStatusEntry
OBJECT-TYPE
Status data from currently queried Rack PDU phase to phase outputs
1.3.6.1.4.1.318.1.1.26.13.1.1not-accessiblemandatory
rPDU2PhaseToPhaseStatusIndex
OBJECT-TYPE
The index to the Rack PDU phase to phase status table entry
1.3.6.1.4.1.318.1.1.26.13.1.1.1INTEGERread-onlymandatory
rPDU2PhaseToPhaseStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.26.13.1.1.2INTEGERread-onlymandatory
rPDU2PhaseToPhaseStatusVoltage1to2
OBJECT-TYPE
Indicates the Voltage, in Volts, of the Rack PDU phase 1 to phase 2 output being queried
1.3.6.1.4.1.318.1.1.26.13.1.1.3INTEGERread-onlymandatory
rPDU2PhaseToPhaseStatusVoltage2to3
OBJECT-TYPE
Indicates the Voltage, in Volts, of the Rack PDU phase 2 to phase 3 output being queried
1.3.6.1.4.1.318.1.1.26.13.1.1.4INTEGERread-onlymandatory
rPDU2PhaseToPhaseStatusVoltage3to1
OBJECT-TYPE
Indicates the Voltage, in Volts, of the Rack PDU phase 3 to phase 2 output being queried
1.3.6.1.4.1.318.1.1.26.13.1.1.5INTEGERread-onlymandatory
cooling
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27
coolingUnit
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1
coolingUnitTableSize
OBJECT-TYPE
The number of cooling units accessible via this agent.
1.3.6.1.4.1.318.1.1.27.1.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitTable
OBJECT-TYPE
A table of cooling unit level data.
1.3.6.1.4.1.318.1.1.27.1.2not-accessiblemandatory
coolingUnitEntry
OBJECT-TYPE
An element of coolingUnitTable.
1.3.6.1.4.1.318.1.1.27.1.2.1not-accessiblemandatory
coolingUnitTableIndex
OBJECT-TYPE
The unit reference identifier for this table and all other table entries subordinate to coolingUnits.
1.3.6.1.4.1.318.1.1.27.1.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitAbout
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.3
coolingUnitAboutTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitAboutTable.
1.3.6.1.4.1.318.1.1.27.1.3.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitAboutTable
OBJECT-TYPE
A table of unit reference information.
1.3.6.1.4.1.318.1.1.27.1.3.2not-accessiblemandatory
coolingUnitAboutEntry
OBJECT-TYPE
An element of coolingUnitAboutTable.
1.3.6.1.4.1.318.1.1.27.1.3.2.1not-accessiblemandatory
coolingUnitAboutTableIndex
OBJECT-TYPE
The static reference identifier for each table entry.
1.3.6.1.4.1.318.1.1.27.1.3.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitAboutDescription
OBJECT-TYPE
A text description of the information presented in coolingUnitAboutValue.
1.3.6.1.4.1.318.1.1.27.1.3.2.1.2DisplayStringread-onlymandatory
coolingUnitAboutValue
OBJECT-TYPE
The actual value of the current table entry.
1.3.6.1.4.1.318.1.1.27.1.3.2.1.3DisplayStringread-onlymandatory
coolingUnitStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.4
coolingUnitStatusAnalog
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.4.1
coolingUnitStatusAnalogTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitStatusAnalogTable.
1.3.6.1.4.1.318.1.1.27.1.4.1.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitStatusAnalogTable
OBJECT-TYPE
A table of analog unit status data.
1.3.6.1.4.1.318.1.1.27.1.4.1.2not-accessiblemandatory
coolingUnitStatusAnalogEntry
OBJECT-TYPE
An element of coolingUnitStatusAnalogTable.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1not-accessiblemandatory
coolingUnitStatusAnalogTableIndex
OBJECT-TYPE
The static reference identifier for each table entry.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitStatusAnalogDescription
OBJECT-TYPE
A text description of the information presented in coolingUnitStatusAnalogValue.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.2DisplayStringread-onlymandatory
coolingUnitStatusAnalogValue
OBJECT-TYPE
The scaled value of the current table entry (multiplied by coolingUnitStatusAnalogScale for integer presentation).
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.3INTEGERread-onlymandatory
coolingUnitStatusAnalogUnits
OBJECT-TYPE
The unit of measure by which coolingUnitStatusAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.4DisplayStringread-onlymandatory
coolingUnitStatusAnalogScale
OBJECT-TYPE
The factor by which coolingUnitStatusAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.5INTEGERread-onlymandatory
coolingUnitStatusDiscrete
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.4.2
coolingUnitStatusDiscreteTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitStatusDiscreteTable.
1.3.6.1.4.1.318.1.1.27.1.4.2.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitStatusDiscreteTable
OBJECT-TYPE
A table of discrete unit status data.
1.3.6.1.4.1.318.1.1.27.1.4.2.2not-accessiblemandatory
coolingUnitStatusDiscreteEntry
OBJECT-TYPE
An element of coolingUnitStatusDiscreteTable.
1.3.6.1.4.1.318.1.1.27.1.4.2.2.1not-accessiblemandatory
coolingUnitStatusDiscreteTableIndex
OBJECT-TYPE
The static reference identifier for each table entry.
1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitStatusDiscreteDescription
OBJECT-TYPE
A text description of the information presented in this table's 'value' OIDs.
1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.2DisplayStringread-onlymandatory
coolingUnitStatusDiscreteValueAsString
OBJECT-TYPE
The actual value of the current table entry expressed as a string.
1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.3DisplayStringread-onlymandatory
coolingUnitStatusDiscreteValueAsInteger
OBJECT-TYPE
The actual value of the current table entry expressed as an integer value.
1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.4INTEGERread-onlymandatory
coolingUnitStatusDiscreteIntegerReferenceKey
OBJECT-TYPE
A complete listing of all possible coolingUnitStatusDiscreteValueAsInteger values paired with their identifying strings.
1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.5DisplayStringread-onlymandatory
coolingUnitConfiguration
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.5
coolingUnitConfigurationAnalog
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.5.1
coolingUnitConfigurationAnalogTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitConfigurationAnalogTable.
1.3.6.1.4.1.318.1.1.27.1.5.1.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitConfigurationAnalogTable
OBJECT-TYPE
A table of analog unit configuration data.
1.3.6.1.4.1.318.1.1.27.1.5.1.2not-accessiblemandatory
coolingUnitConfigurationAnalogEntry
OBJECT-TYPE
An element of coolingUnitConfigurationAnalogTable.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1not-accessiblemandatory
coolingUnitConfigurationAnalogTableIndex
OBJECT-TYPE
The static reference identifier for each table entry.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitConfigurationAnalogDescription
OBJECT-TYPE
A text description of the information presented in coolingUnitConfigurationAnalogValue.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.2DisplayStringread-onlymandatory
coolingUnitConfigurationAnalogValue
OBJECT-TYPE
The scaled value of the current table entry (multiplied by coolingUnitConfigurationAnalogScale for integer presentation).
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.3INTEGERread-writemandatory
coolingUnitConfigurationAnalogUnits
OBJECT-TYPE
The unit of measure by which coolingUnitConfigurationAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.4DisplayStringread-onlymandatory
coolingUnitConfigurationAnalogScale
OBJECT-TYPE
The factor by which coolingUnitConfigurationAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.5INTEGERread-onlymandatory
coolingUnitConfigurationAnalogAccess
OBJECT-TYPE
A description of available access to coolingUnitConfigurationAnalogValue via SNMP client.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.6INTEGER {readOnly(1), readWrite(2)}read-onlymandatory
coolingUnitConfigurationAnalogMinimum
OBJECT-TYPE
The minimum possible value of coolingUnitConfigurationAnalogValue.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.7INTEGERread-onlymandatory
coolingUnitConfigurationAnalogMaximum
OBJECT-TYPE
The maximum possible value of coolingUnitConfigurationAnalogValue.
1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.8INTEGERread-onlymandatory
coolingUnitConfigurationDiscrete
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.5.2
coolingUnitConfigurationDiscreteTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitConfigurationDiscreteTable.
1.3.6.1.4.1.318.1.1.27.1.5.2.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitConfigurationDiscreteTable
OBJECT-TYPE
A table of discrete unit configuration data.
1.3.6.1.4.1.318.1.1.27.1.5.2.2not-accessiblemandatory
coolingUnitConfigurationDiscreteEntry
OBJECT-TYPE
An element of coolingUnitConfigurationDiscreteTable.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1not-accessiblemandatory
coolingUnitConfigurationDiscreteTableIndex
OBJECT-TYPE
The static reference identifier for each table entry.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitConfigurationDiscreteDescription
OBJECT-TYPE
A text description of the information presented in this table's 'value' OIDs.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.2DisplayStringread-onlymandatory
coolingUnitConfigurationDiscreteValueAsString
OBJECT-TYPE
The actual value of the current table entry expressed as a string.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.3DisplayStringread-onlymandatory
coolingUnitConfigurationDiscreteValueAsInteger
OBJECT-TYPE
The actual value of the current table entry expressed as an integer value.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.4INTEGERread-writemandatory
coolingUnitConfigurationDiscreteIntegerReferenceKey
OBJECT-TYPE
A complete listing of all possible coolingUnitConfigurationDiscreteValueAsInteger values paired with their identifying strings.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.5DisplayStringread-onlymandatory
coolingUnitConfigurationDiscreteAccess
OBJECT-TYPE
A description of available access to coolingUnitConfigurationDiscreteValueAsInteger via SNMP client.
1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.6INTEGER {readOnly(1), readWrite(2)}read-onlymandatory
coolingUnitConfigurationString
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.5.3
coolingUnitConfigurationStringTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitConfigurationStringTable.
1.3.6.1.4.1.318.1.1.27.1.5.3.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitConfigurationStringTable
OBJECT-TYPE
A table of unit configuration strings.
1.3.6.1.4.1.318.1.1.27.1.5.3.2not-accessiblemandatory
coolingUnitConfigurationStringEntry
OBJECT-TYPE
An element of coolingUnitConfigurationStringTable.
1.3.6.1.4.1.318.1.1.27.1.5.3.2.1not-accessiblemandatory
coolingUnitConfigurationStringTableIndex
OBJECT-TYPE
The static reference identifier for each table entry.
1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitConfigurationStringDescription
OBJECT-TYPE
A text description of the information presented in coolingUnitConfigurationStringValue.
1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.2DisplayStringread-onlymandatory
coolingUnitConfigurationStringValue
OBJECT-TYPE
The actual value of the current table entry.
1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.3DisplayStringread-writemandatory
coolingUnitConfigurationStringMaxLength
OBJECT-TYPE
The maximum string length supported by coolingUnitConfigurationStringValue.
1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.4INTEGERread-onlymandatory
coolingUnitConfigurationStringAccess
OBJECT-TYPE
A description of available access to coolingUnitConfigurationStringValue via SNMP client.
1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.5INTEGER {readOnly(1), readWrite(2)}read-onlymandatory
coolingUnitExtended
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.6
coolingUnitExtendedAnalog
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.6.1
coolingUnitExtendedAnalogTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitExtendedAnalogTable.
1.3.6.1.4.1.318.1.1.27.1.6.1.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitExtendedAnalogTable
OBJECT-TYPE
A table of secondary analog data for the cooling unit or one of its components.
1.3.6.1.4.1.318.1.1.27.1.6.1.2not-accessiblemandatory
coolingUnitExtendedAnalogEntry
OBJECT-TYPE
An element of coolingUnitExtendedAnalogTable.
1.3.6.1.4.1.318.1.1.27.1.6.1.2.1not-accessiblemandatory
coolingUnitExtendedAnalogTableIndex
OBJECT-TYPE
The static reference identifier for each table entry. This identifier may reference different table entries in different unit models.
1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitExtendedAnalogDescription
OBJECT-TYPE
A text description of the information presented in coolingUnitExtendedAnalogValue.
1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.2DisplayStringread-onlymandatory
coolingUnitExtendedAnalogValue
OBJECT-TYPE
The scaled value of the current table entry (multiplied by coolingUnitExtendedAnalogScale for integer presentation).
1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.3INTEGERread-onlymandatory
coolingUnitExtendedAnalogUnits
OBJECT-TYPE
The unit of measure by which coolingUnitExtendedAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.4DisplayStringread-onlymandatory
coolingUnitExtendedAnalogScale
OBJECT-TYPE
The factor by which coolingUnitExtendedAnalogValue is expressed.
1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.5INTEGERread-onlymandatory
coolingUnitExtendedDiscrete
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.6.2
coolingUnitExtendedDiscreteTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitExtendedDiscreteTable.
1.3.6.1.4.1.318.1.1.27.1.6.2.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitExtendedDiscreteTable
OBJECT-TYPE
A table of secondary discrete cooling unit data.
1.3.6.1.4.1.318.1.1.27.1.6.2.2not-accessiblemandatory
coolingUnitExtendedDiscreteEntry
OBJECT-TYPE
An element of coolingUnitExtendedDiscreteTable.
1.3.6.1.4.1.318.1.1.27.1.6.2.2.1not-accessiblemandatory
coolingUnitExtendedDiscreteTableIndex
OBJECT-TYPE
The static reference identifier for each table entry. This identifier may reference different table entries in different unit models.
1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitExtendedDiscreteDescription
OBJECT-TYPE
A text description of the information presented in this table's 'value' OIDs.
1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.2DisplayStringread-onlymandatory
coolingUnitExtendedDiscreteValueAsString
OBJECT-TYPE
The actual value of the current table entry expressed as a string.
1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.3DisplayStringread-onlymandatory
coolingUnitExtendedDiscreteValueAsInteger
OBJECT-TYPE
The actual value of the current table entry expressed as an integer value.
1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.4INTEGERread-onlymandatory
coolingUnitExtendedDiscreteIntegerReferenceKey
OBJECT-TYPE
A complete listing of all possible coolingUnitExtendedDiscreteValueAsInteger values paired with their identifying strings.
1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.5DisplayStringread-onlymandatory
coolingUnitExtendedString
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.27.1.6.3
coolingUnitExtendedStringTableSize
OBJECT-TYPE
The potential number of entries available in coolingUnitExtendedStringTable.
1.3.6.1.4.1.318.1.1.27.1.6.3.1INTEGER (0..2147483647)read-onlymandatory
coolingUnitExtendedStringTable
OBJECT-TYPE
A table of secondary unit reference data.
1.3.6.1.4.1.318.1.1.27.1.6.3.2not-accessiblemandatory
coolingUnitExtendedStringEntry
OBJECT-TYPE
An element of coolingUnitExtendedStringTable.
1.3.6.1.4.1.318.1.1.27.1.6.3.2.1not-accessiblemandatory
coolingUnitExtendedStringTableIndex
OBJECT-TYPE
The static reference identifier for each table entry. This identifier may reference different table entries in different unit models.
1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.1INTEGER (1..2147483647)not-accessiblemandatory
coolingUnitExtendedStringDescription
OBJECT-TYPE
A text description of the information presented in coolingUnitExtendedStringValue.
1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.2DisplayStringread-onlymandatory
coolingUnitExtendedStringValue
OBJECT-TYPE
The actual value of the current table entry.
1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.3DisplayStringread-onlymandatory
powerManagementModule
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28
pmmIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.1
pmmIdentModelNumber
OBJECT-TYPE
A character string identifying the model number of the PMM. This value is set at the factory.
1.3.6.1.4.1.318.1.1.28.1.1DisplayStringread-onlymandatory
pmmIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the PMM. This value is set at the factory.
1.3.6.1.4.1.318.1.1.28.1.2DisplayStringread-onlymandatory
pmmIdentDateOfManufacture
OBJECT-TYPE
The date when the PMM was manufactured in mm/dd/yyyy format. This value is set at the factory.
1.3.6.1.4.1.318.1.1.28.1.3DisplayStringread-onlymandatory
pmmIdentHMISerialNumber
OBJECT-TYPE
A character string identifying the serial number of the HMI. This value is set at the factory.
1.3.6.1.4.1.318.1.1.28.1.4DisplayStringread-onlymandatory
pmmIdentHMIHardwareRev
OBJECT-TYPE
The hardware revision of the HMI. This value is set at the factory.
1.3.6.1.4.1.318.1.1.28.1.5DisplayStringread-onlymandatory
pmmIdentHMIFirmwareAppRev
OBJECT-TYPE
An ID string identifying the application firmware revision of the HMI.
1.3.6.1.4.1.318.1.1.28.1.6DisplayStringread-onlymandatory
pmmIdentHMIFirmwareAppOSRev
OBJECT-TYPE
An ID string identifying the application operating system firmware revision of the HMI.
1.3.6.1.4.1.318.1.1.28.1.7DisplayStringread-onlymandatory
pmmDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.2
pmmDeviceNominalInputVoltage
OBJECT-TYPE
The nominal input voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service.
1.3.6.1.4.1.318.1.1.28.2.1INTEGERread-onlymandatory
pmmDeviceServiceType
OBJECT-TYPE
The type of utility input to the PMM. Either 3 wires (delta), or 4 wires (wye).
1.3.6.1.4.1.318.1.1.28.2.2INTEGER {threeWire(1), fourWire(2)}read-onlymandatory
pmmDeviceNominalOutputVoltage
OBJECT-TYPE
The nominal line-to-neutral output voltage to the load measured in Volts.
1.3.6.1.4.1.318.1.1.28.2.3INTEGERread-onlymandatory
pmmMonitoring
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.3
pmmInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.3.1
pmmInputMeterTableSize
OBJECT-TYPE
The number of input meters attached to the system.
1.3.6.1.4.1.318.1.1.28.3.1.1INTEGERread-onlymandatory
pmmInputTable
OBJECT-TYPE
A list of input meter entries.
1.3.6.1.4.1.318.1.1.28.3.1.2not-accessiblemandatory
pmmInputEntry
OBJECT-TYPE
An entry containing information applicable to a particular input meter.
1.3.6.1.4.1.318.1.1.28.3.1.2.1not-accessiblemandatory
pmmInputMeterIndex
OBJECT-TYPE
The input meter identifier.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.1INTEGERread-onlymandatory
pmmInputFrequency
OBJECT-TYPE
The input frequency in tenths of Hertz.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.2INTEGERread-onlymandatory
pmmInputTotalActivePower
OBJECT-TYPE
Shows the total input active power in tenths of kW.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.3INTEGERread-onlymandatory
pmmInputTotalApparentPower
OBJECT-TYPE
Shows the total input apparent power in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.4INTEGERread-onlymandatory
pmmInputTotalPowerFactor
OBJECT-TYPE
Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.5INTEGERread-onlymandatory
pmmInputActiveEnergyDelivered
OBJECT-TYPE
Shows the input active energy delivered in tenths of kWh.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.6Integer32read-onlymandatory
pmmInputActiveEnergyReceived
OBJECT-TYPE
Shows the input active energy received in tenths of kWh.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.7Integer32read-onlymandatory
pmmInputApparentEnergyDelivered
OBJECT-TYPE
Shows the input apparent energy delivered in tenths of kVAh.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.8Integer32read-onlymandatory
pmmInputApparentEnergyReceived
OBJECT-TYPE
Shows the input apparent energy received in tenths of kVAh.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.9Integer32read-onlymandatory
pmmInputFrequencyDeviation
OBJECT-TYPE
Shows the input frequency deviation in Hertz.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.10INTEGER {freqDeviationOff(1), freqDeviationPointTwo(2), freqDeviationPointFive(3), freqDeviationOne(4), freqDeviationOnePointFive(5), freqDeviationTwo(6), freqDeviationThree(7), freqDeviationFour(8), freqDeviationFive(9), freqDeviationNine(10)}read-writemandatory
pmmInputPowerFactorDeviation
OBJECT-TYPE
Shows the input power factor deviation. Specified in tenths. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.11INTEGER (0..100)read-writemandatory
pmmInputMinVoltThreshold
OBJECT-TYPE
Threshold below which an input minimum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.12INTEGER (0..100)read-writemandatory
pmmInputLowVoltThreshold
OBJECT-TYPE
Threshold below which an input low voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.13INTEGER (0..100)read-writemandatory
pmmInputHighVoltThreshold
OBJECT-TYPE
Threshold above which an input high voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.14INTEGER (0..120)read-writemandatory
pmmInputMaxVoltThreshold
OBJECT-TYPE
Threshold above which an input maximum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.15INTEGER (0..120)read-writemandatory
pmmInputMinCurrentThreshold
OBJECT-TYPE
Threshold below which an input minimum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.16INTEGER (0..100)read-writemandatory
pmmInputLowCurrentThreshold
OBJECT-TYPE
Threshold below which an input low current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.17INTEGER (0..100)read-writemandatory
pmmInputHighCurrentThreshold
OBJECT-TYPE
Threshold above which an input high current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.18INTEGER (0..110)read-writemandatory
pmmInputMaxCurrentThreshold
OBJECT-TYPE
Threshold above which an input maximum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.19INTEGER (0..100)read-writemandatory
pmmInputMinApparentPowerThreshold
OBJECT-TYPE
Threshold below which an input minimum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.20INTEGER (0..100)read-writemandatory
pmmInputMaxApparentPowerThreshold
OBJECT-TYPE
Threshold above which an input maximum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.21INTEGER (0..110)read-writemandatory
pmmInputOverActivePowerThreshold
OBJECT-TYPE
Threshold above which an input over active power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.22INTEGER (0..100)read-writemandatory
pmmInputBreakerState
OBJECT-TYPE
This value indicates the current state of input breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.23INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
pmmInputBreakerOpenAlarm
OBJECT-TYPE
Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.24INTEGER {enabled(1), disabled(2), unknown(3)}read-writemandatory
pmmInputAverageCurrent
OBJECT-TYPE
Input Average current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.25INTEGERread-onlymandatory
pmmInputNeturalCurrent
OBJECT-TYPE
Input Netural current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.26INTEGERread-onlymandatory
pmmInputMaxInstantaneousNeutralCurrent
OBJECT-TYPE
Input maximum instantaneous neutral current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.27INTEGERread-onlymandatory
pmmInputAverageCurrentTHD
OBJECT-TYPE
Input average harmonic distortions. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.28INTEGERread-onlymandatory
pmmInputAverageVoltageLtoL
OBJECT-TYPE
Input Average Line to Line voltage. Measured in tenths of Volts. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.29INTEGERread-onlymandatory
pmmInputAverageVoltageLtoN
OBJECT-TYPE
Input Average Line to Neutral voltage. Measured in tenths of Volts. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.30INTEGERread-onlymandatory
pmmInputLoad
OBJECT-TYPE
Total load of input breaker in percentage. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.31INTEGERread-onlymandatory
pmmInputMeterFirmwareVersion
OBJECT-TYPE
Shows the input meter firmware revision. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.32INTEGERread-onlymandatory
pmmInputMeterSerialNumber
OBJECT-TYPE
Shows the input meter serial number. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.33DisplayStringread-onlymandatory
pmmInputEnergyUsageAccumulatedTotal
OBJECT-TYPE
Shows the total accumulated input energy usage in kwh. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.34INTEGERread-onlymandatory
pmmInputPhaseLoss
OBJECT-TYPE
Threshold below which an input phase loss condition will be generated. Specified as a percent deviation from phase to neutral nominal voltage. A value of zero indicates that the threshold is disabled. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.35INTEGERread-onlymandatory
pmmInputBreakerCTSize
OBJECT-TYPE
Shows the input breaker CT size. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.36INTEGERread-onlymandatory
pmmInputBreakerRating
OBJECT-TYPE
Shows the input breaker rating in Amps(A). Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.37INTEGERread-onlymandatory
pmmInputKWHResetDate
OBJECT-TYPE
The date that the kWh usage was reset, in the format mm/dd/yyyy.
1.3.6.1.4.1.318.1.1.28.3.1.2.1.38DisplayStringread-onlymandatory
pmmInputAlarmGeneration
OBJECT-TYPE
Alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.39INTEGERread-onlymandatory
pmmInputVoltageMaximumAlarm
OBJECT-TYPE
Voltage maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.40INTEGERread-onlymandatory
pmmInputVoltageHighAlarm
OBJECT-TYPE
Voltage high alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.41INTEGERread-onlymandatory
pmmInputVoltageLowAlarm
OBJECT-TYPE
Voltage low alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.42INTEGERread-onlymandatory
pmmInputVoltageMinimumAlarm
OBJECT-TYPE
Voltage minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.43INTEGERread-onlymandatory
pmmInputCurrentMaximumAlarm
OBJECT-TYPE
Current maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.44INTEGERread-onlymandatory
pmmInputCurrentHighAlarm
OBJECT-TYPE
Current high alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.45INTEGERread-onlymandatory
pmmInputCurrentLowAlarm
OBJECT-TYPE
Current low alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.46INTEGERread-onlymandatory
pmmInputCurrentMinimumAlarm
OBJECT-TYPE
Current minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.47INTEGERread-onlymandatory
pmmInputApparentPowerMaximumAlarm
OBJECT-TYPE
Apparent Power maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.48INTEGERread-onlymandatory
pmmInputApparentPowerMinimumAlarm
OBJECT-TYPE
Apparent Power minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.49INTEGERread-onlymandatory
pmmInputKWOverAlarm
OBJECT-TYPE
Over active power alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.50INTEGERread-onlymandatory
pmmInputPhaseLossAlarm
OBJECT-TYPE
Phase loss alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.51INTEGERread-onlymandatory
pmmInputPowerFactorTotalAlarm
OBJECT-TYPE
Total power factor alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.52INTEGERread-onlymandatory
pmmInputFrequencyDeviationAlarm
OBJECT-TYPE
Frequency deviation alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.1.2.1.53INTEGERread-onlymandatory
pmmInputPhaseTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the value of pmmInputMeterTableSize OID.
1.3.6.1.4.1.318.1.1.28.3.1.3not-accessiblemandatory
pmmInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase.
1.3.6.1.4.1.318.1.1.28.3.1.3.1not-accessiblemandatory
pmmInputMeterNum
OBJECT-TYPE
The input meter identifier.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.1INTEGERread-onlymandatory
pmmInputPhase
OBJECT-TYPE
Input phase index.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.2INTEGERread-onlymandatory
pmmInputVoltageLtoL
OBJECT-TYPE
Line-to-line input voltage available. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.3INTEGERread-onlymandatory
pmmInputVoltageLtoN
OBJECT-TYPE
Line-to-neutral input voltage available. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.4INTEGERread-onlymandatory
pmmInputPhaseCurrent
OBJECT-TYPE
Input current per phase. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.5INTEGERread-onlymandatory
pmmInputActivePower
OBJECT-TYPE
Input power per phase. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.6INTEGERread-onlymandatory
pmmInputApparentPower
OBJECT-TYPE
Input power per phase. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.7INTEGERread-onlymandatory
pmmInputPowerFactor
OBJECT-TYPE
Indicates the power factor of the input per phase. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.8INTEGERread-onlymandatory
pmmInputMaxInstantaneousCurrent
OBJECT-TYPE
Input maximum phase instantaneous current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.9INTEGERread-onlymandatory
pmmInputPhaseAngle
OBJECT-TYPE
Current phase Angle. Measured in tenths of decimal
1.3.6.1.4.1.318.1.1.28.3.1.3.1.10INTEGERread-onlymandatory
pmmInputTHDLtoL
OBJECT-TYPE
Input harmonic distortions line to line.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.11INTEGERread-onlymandatory
pmmInputTHDLtoN
OBJECT-TYPE
Input harmonic distortions line to netural.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.12INTEGERread-onlymandatory
pmmInputCurrentTHD
OBJECT-TYPE
Input harmonic distortions. Returns -1 if unsupported or failed. Specified in tenths.
1.3.6.1.4.1.318.1.1.28.3.1.3.1.13INTEGERread-onlymandatory
pmmOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.3.2
pmmOutputMeterTableSize
OBJECT-TYPE
The number of output meters attached to the system.
1.3.6.1.4.1.318.1.1.28.3.2.1INTEGERread-onlymandatory
pmmOutputTable
OBJECT-TYPE
A list of output meter entries.
1.3.6.1.4.1.318.1.1.28.3.2.2not-accessiblemandatory
pmmOutputEntry
OBJECT-TYPE
An entry containing information applicable to a particular output meter.
1.3.6.1.4.1.318.1.1.28.3.2.2.1not-accessiblemandatory
pmmOutputMeterIndex
OBJECT-TYPE
The output meter identifier.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.1INTEGERread-onlymandatory
pmmOutputFrequency
OBJECT-TYPE
The output frequency in tenths of Hertz.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.2INTEGERread-onlymandatory
pmmOutputTotalActivePower
OBJECT-TYPE
Shows the total output active power in tenths of kW.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.3INTEGERread-onlymandatory
pmmOutputTotalApparentPower
OBJECT-TYPE
Shows the total output apparent power in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.4INTEGERread-onlymandatory
pmmOutputTotalPowerFactor
OBJECT-TYPE
Indicates the total power factor. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.5INTEGERread-onlymandatory
pmmOutputActiveEnergyDelivered
OBJECT-TYPE
Shows the output active energy delivered in tenths of kWh.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.6Integer32read-onlymandatory
pmmOutputActiveEnergyReceived
OBJECT-TYPE
Shows the output active energy received in tenths of kWh.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.7Integer32read-onlymandatory
pmmOutputApparentEnergyDelivered
OBJECT-TYPE
Shows the output apparent energy delivered in tenths of kVAh.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.8Integer32read-onlymandatory
pmmOutputApparentEnergyReceived
OBJECT-TYPE
Shows the output apparent energy received in tenths of kVAh.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.9Integer32read-onlymandatory
pmmOutputFrequencyDeviation
OBJECT-TYPE
Shows the output frequency deviation in Hertz.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.10INTEGER {freqDeviationOff(1), freqDeviationPointTwo(2), freqDeviationPointFive(3), freqDeviationOne(4), freqDeviationOnePointFive(5), freqDeviationTwo(6), freqDeviationThree(7), freqDeviationFour(8), freqDeviationFive(9), freqDeviationNine(10)}read-writemandatory
pmmOutputPowerFactorDeviation
OBJECT-TYPE
Shows the output power factor deviation. Specified in tenths. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.11INTEGER (0..100)read-writemandatory
pmmOutputMinVoltThreshold
OBJECT-TYPE
Threshold below which an output minimum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.12INTEGER (0..100)read-writemandatory
pmmOutputLowVoltThreshold
OBJECT-TYPE
Threshold below which an output low voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.13INTEGER (0..100)read-writemandatory
pmmOutputHighVoltThreshold
OBJECT-TYPE
Threshold above which an output high voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.14INTEGER (0..120)read-writemandatory
pmmOutputMaxVoltThreshold
OBJECT-TYPE
Threshold above which an output maximum voltage condition will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.15INTEGER (0..120)read-writemandatory
pmmOutputMinCurrentThreshold
OBJECT-TYPE
Threshold below which an output minimum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.16INTEGER (0..100)read-writemandatory
pmmOutputLowCurrentThreshold
OBJECT-TYPE
Threshold below which an output low current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.17INTEGER (0..100)read-writemandatory
pmmOutputHighCurrentThreshold
OBJECT-TYPE
Threshold above which an output high current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.18INTEGER (0..110)read-writemandatory
pmmOutputMaxCurrentThreshold
OBJECT-TYPE
Threshold above which an output maximum current condition will be generated. Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.19INTEGER (0..100)read-writemandatory
pmmOutputMinApparentPowerThreshold
OBJECT-TYPE
Threshold below which an output minimum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.20INTEGER (0..100)read-writemandatory
pmmOutputMaxApparentPowerThreshold
OBJECT-TYPE
Threshold above which an output maximum apparent power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.21INTEGER (0..110)read-writemandatory
pmmOutputOverActivePowerThreshold
OBJECT-TYPE
Threshold above which an output over active power condition will be generated. Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.22INTEGER (0..100)read-writemandatory
pmmOutputPhaseLossThreshold
OBJECT-TYPE
Threshold below which an output phase loss condition will be generated. Specified as a percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.23INTEGER (0..100)read-writemandatory
pmmOutputBreakerState
OBJECT-TYPE
This value indicates the current state of output breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.24INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
pmmOutputBreakerOpenAlarm
OBJECT-TYPE
Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.2.2.1.25INTEGER {enabled(1), disabled(2), unknown(3)}read-writemandatory
pmmOutputPhaseTable
OBJECT-TYPE
A list of output table entries. The number of entries is given by the value of pmmOutputMeterTableSize OID.
1.3.6.1.4.1.318.1.1.28.3.2.3not-accessiblemandatory
pmmOutputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular output phase.
1.3.6.1.4.1.318.1.1.28.3.2.3.1not-accessiblemandatory
pmmOutputMeterNum
OBJECT-TYPE
The output meter identifier.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.1INTEGERread-onlymandatory
pmmOutputPhase
OBJECT-TYPE
Output phase index.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.2INTEGERread-onlymandatory
pmmOutputVoltageLtoL
OBJECT-TYPE
Line-to-line output voltage available. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.3INTEGERread-onlymandatory
pmmOutputVoltageLtoN
OBJECT-TYPE
Line-to-neutral output voltage available. Measured in tenths of Volts.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.4INTEGERread-onlymandatory
pmmOutputPhaseCurrent
OBJECT-TYPE
Load current per phase. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.5INTEGERread-onlymandatory
pmmOutputActivePower
OBJECT-TYPE
Output power per phase. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.6INTEGERread-onlymandatory
pmmOutputApparentPower
OBJECT-TYPE
Output power per phase. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.7INTEGERread-onlymandatory
pmmOutputPowerFactor
OBJECT-TYPE
Indicates the power factor of the output per phase. A value of 100 representing a unity power factor (1.00). Specified in hundredths.
1.3.6.1.4.1.318.1.1.28.3.2.3.1.8INTEGERread-onlymandatory
pmmBranch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.3.3
pmmnumofBranchMeters
OBJECT-TYPE
The number of branch meters attached to the system.
1.3.6.1.4.1.318.1.1.28.3.3.1INTEGERread-onlymandatory
pmmBranchBreakerTableSize
OBJECT-TYPE
The number of branch breaker entries.
1.3.6.1.4.1.318.1.1.28.3.3.2INTEGERread-onlymandatory
pmmBranchBreakerTable
OBJECT-TYPE
A list of branch breaker table entries. The number of entries is contained in the pmmBranchBreakerTableSize OID.
1.3.6.1.4.1.318.1.1.28.3.3.3not-accessiblemandatory
pmmBranchBreakerEntry
OBJECT-TYPE
An entry containing information applicable to a particular branch breaker (panel/circuit position).
1.3.6.1.4.1.318.1.1.28.3.3.3.1not-accessiblemandatory
pmmBranchCircuitMeterIndex
OBJECT-TYPE
Index of branch circuit meter in the table.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.1INTEGERread-onlymandatory
pmmBranchCircuitIndex
OBJECT-TYPE
The branch circuit index.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.2INTEGERread-onlymandatory
pmmBranchCircuitNumberOfPoles
OBJECT-TYPE
The number of poles.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.3INTEGERread-onlymandatory
pmmBranchCircuitPhase
OBJECT-TYPE
The phase associated with branch circuit.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.4DisplayStringread-onlymandatory
pmmBranchCircuitBreakerIdentifier
OBJECT-TYPE
The branch circuit identifier.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.5DisplayStringread-onlymandatory
pmmBranchCircuitLoadIdentifier
OBJECT-TYPE
Identifies the name or location of the branch circuit load.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.6DisplayStringread-onlymandatory
pmmBranchCircuitCurrent
OBJECT-TYPE
The branch circuit current Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.7INTEGERread-onlymandatory
pmmBranchCircuitBreakerRating
OBJECT-TYPE
The rating of the branch circuit breaker in Amps.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.8INTEGERread-onlymandatory
pmmBranchCircuitTotalActivePower
OBJECT-TYPE
Branch circuit total power. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.9INTEGERread-onlymandatory
pmmBranchCircuitTotalApparentPower
OBJECT-TYPE
Branch circuit total apparent power. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.10INTEGERread-onlymandatory
pmmBranchCircuitEnergyUsage
OBJECT-TYPE
Indicates the accumulated energy usage in tenths of kWh. Displayed as 0 when not available or no energy used.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.11Gaugeread-onlymandatory
pmmBranchCircuitEnergyUsageResetDate
OBJECT-TYPE
The date that the kWh usage was reset, in the format mm/dd/yyyy.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.12DisplayStringread-onlymandatory
pmmBranchCircuitTotalPowerFactor
OBJECT-TYPE
Indicates the total power factor of the branch circuit output. A value of 100 representing a unity power factor (1.00) Specified in hundredths.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.13INTEGERread-onlymandatory
pmmBranchCircuitBreakerState
OBJECT-TYPE
This value indicates the current state of branch circuit breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.14INTEGER {open(1), closed(2), unknown(3)}read-onlymandatory
pmmBranchCircuitMinCurrentThreshold
OBJECT-TYPE
Threshold below which a branch circuit minimum current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.15INTEGER (0..100)read-writemandatory
pmmBranchCircuitLowCurrentThreshold
OBJECT-TYPE
Threshold below which a branch circuit low current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.16INTEGER (0..100)read-writemandatory
pmmBranchCircuitHighCurrentThreshold
OBJECT-TYPE
Threshold above which a branch circuit high current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.17INTEGER (0..100)read-writemandatory
pmmBranchCircuitMaxCurrentThreshold
OBJECT-TYPE
Threshold above which a branch circuit maximum current condition will be generated. Specified as a percent of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.18INTEGER (0..100)read-writemandatory
pmmBranchCircuitMinApparentPowerThreshold
OBJECT-TYPE
Threshold below which a branch circuit minimum apparent power condition will be generated. Specified as a percent of the branch breaker apparent power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.19INTEGER (0..100)read-writemandatory
pmmBranchCircuitMaxApparentPowerThreshold
OBJECT-TYPE
Threshold above which a branch circuit maximum apparent power condition will be generated. Specified as a percent of the branch breaker apparent power rating. A value of zero indicates that the threshold is disabled.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.20INTEGER (0..100)read-writemandatory
pmmBranchCircuitAlaramGeneration
OBJECT-TYPE
Alarm generation status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.21INTEGER {enabled(1), disabled(2), unknown(3)}read-onlymandatory
pmmBranchCircuitBreakerOpenAlarm
OBJECT-TYPE
Breaker open alarm status. 1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.22INTEGER {enabled(1), disabled(2), unknown(3)}read-writemandatory
pmmBranchCircuitBreakerAverageCurrent
OBJECT-TYPE
Branch breaker current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.23INTEGERread-onlymandatory
pmmBranchCircuitMaxInstantaneousCurrentPhase
OBJECT-TYPE
Branch circuit maximum instantaneous current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.24INTEGERread-onlymandatory
pmmBranchCircuitBreakerMaxInstantaneousAverageCurrent
OBJECT-TYPE
Branch breaker maximum instantaneous current. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.25INTEGERread-onlymandatory
pmmBranchCircuitAngle
OBJECT-TYPE
Branch circuit phase angle. Measured in tenths of Decimal.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.26INTEGERread-onlymandatory
pmmBranchCircuitActivePower
OBJECT-TYPE
Branch circuit Active power. Measured in tenths of kW.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.27INTEGERread-onlymandatory
pmmBranchCircuitApparentPower
OBJECT-TYPE
Branch circuit apparent power. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.28INTEGERread-onlymandatory
pmmBranchCircuitBreakerEnergyTotalUsage
OBJECT-TYPE
Indicates the circuit Breaker total accumulated energy usage in tenths of kWh. Displayed as 0 when not available or no energy used.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.29Gaugeread-onlymandatory
pmmBranchCircuitPowerFactor
OBJECT-TYPE
Indicates the power factor of the branch circuit. A value of 100 representing a unity power factor (1.00) Specified in hundredths.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.30INTEGERread-onlymandatory
pmmBranchCircuitTHD
OBJECT-TYPE
Branch circuit harmonic distortion.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.31INTEGERread-onlymandatory
pmmBranchCircuitBreakerTHD
OBJECT-TYPE
Branch Breaker harmonic distortion.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.32INTEGERread-onlymandatory
pmmBranchCircuitBreakerLoad
OBJECT-TYPE
Total load on the Breaker. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.33INTEGERread-onlymandatory
pmmBranchCircuitBranchNumber
OBJECT-TYPE
The branch number. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.34INTEGERread-onlymandatory
pmmBranchCircuitChannelCTSize
OBJECT-TYPE
The branch CT Size. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.3.3.1.35INTEGERread-onlymandatory
pmmBranchcircuitCurrentMaxAlarm
OBJECT-TYPE
Current maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.3.3.1.36INTEGERread-onlymandatory
pmmBranchcircuitCurrentHighAlarm
OBJECT-TYPE
Current high alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.3.3.1.37INTEGERread-onlymandatory
pmmBranchcircuitCurrentLowAlarm
OBJECT-TYPE
Current low alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.3.3.1.38INTEGERread-onlymandatory
pmmBranchcircuitCurrentMinAlarm
OBJECT-TYPE
Current minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.3.3.1.39INTEGERread-onlymandatory
pmmBranchcircuitApparentPowerMaxAlarm
OBJECT-TYPE
Apparent power maximum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.3.3.1.40INTEGERread-onlymandatory
pmmBranchcircuitApparentPowerMinAlarm
OBJECT-TYPE
Apparent power minimum alarm generation status. 1 - enabled 2 - disabled 3 - unknown
1.3.6.1.4.1.318.1.1.28.3.3.3.1.41INTEGERread-onlymandatory
pmmSiteConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.28.3.4
pmmSiteConfigTableSize
OBJECT-TYPE
The number of site configuration set supported by system.
1.3.6.1.4.1.318.1.1.28.3.4.1INTEGERread-onlymandatory
pmmSiteConfigTable
OBJECT-TYPE
A list of PMM site configurable entries.
1.3.6.1.4.1.318.1.1.28.3.4.2not-accessiblemandatory
pmmSiteConfigEntry
OBJECT-TYPE
An entry containing information applicable to a particular site configuration.
1.3.6.1.4.1.318.1.1.28.3.4.2.1not-accessiblemandatory
pmmSiteConfigIndex
OBJECT-TYPE
PMM site configuration identifier.
1.3.6.1.4.1.318.1.1.28.3.4.2.1.1INTEGERread-onlymandatory
pmmSiteConfigNominalPtoPVoltage
OBJECT-TYPE
The nominal input phase to phase voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service.
1.3.6.1.4.1.318.1.1.28.3.4.2.1.2INTEGERread-onlymandatory
pmmSiteConfigNominalPtoNVoltage
OBJECT-TYPE
The nominal input phase to neutral voltage to the PMM. Measured in Volts, line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service.
1.3.6.1.4.1.318.1.1.28.3.4.2.1.3INTEGERread-onlymandatory
pmmSiteConfigNominalCurrent
OBJECT-TYPE
The nominal input current to the PMM. Measured in tenths of Amps.
1.3.6.1.4.1.318.1.1.28.3.4.2.1.4INTEGERread-onlymandatory
pmmSiteConfigNominalFrequency
OBJECT-TYPE
The nominal input frequency to the PMM. Measured in tenths of Hertz.
1.3.6.1.4.1.318.1.1.28.3.4.2.1.5INTEGERread-onlymandatory
pmmSiteConfigNominalApparentPower
OBJECT-TYPE
The nominal input apparent power to the PMM. Measured in tenths of kVA.
1.3.6.1.4.1.318.1.1.28.3.4.2.1.6INTEGERread-onlymandatory
pmmSiteConfigServiceType
OBJECT-TYPE
The type of utility input to the PMM. Either 3 wires (delta), or 4 wires (wye).
1.3.6.1.4.1.318.1.1.28.3.4.2.1.7INTEGER {threeWire(1), fourWire(2)}read-onlymandatory
pmmSiteConfigNumberofPanel
OBJECT-TYPE
The number of panels present. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.4.3INTEGERread-onlymandatory
pmmSiteConfigNumberofChannel
OBJECT-TYPE
The number of channels present. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.4.4INTEGERread-onlymandatory
pmmSiteConfigNumberofsources
OBJECT-TYPE
The number of input sources present. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.4.5INTEGERread-onlymandatory
pmmSiteConfigProductModelNumber
OBJECT-TYPE
A character string identifying the model number of the RPP. This value is set at the factory. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.4.6DisplayStringread-onlymandatory
pmmSiteConfigProductSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the RPP. This value is set at the factory. Returns -1 if unsupported or failed.
1.3.6.1.4.1.318.1.1.28.3.4.7DisplayStringread-onlymandatory
charger
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.29
chargerIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.29.1
chargerIdentModel
OBJECT-TYPE
A character string identifying the model name of the Charger. This value is set at the factory.
1.3.6.1.4.1.318.1.1.29.1.1DisplayStringread-onlymandatory
chargerBasicIdentName
OBJECT-TYPE
An 8 byte ID string identifying the Charger. This object can be set by the administrator.
1.3.6.1.4.1.318.1.1.29.1.2DisplayStringread-writemandatory
chargerIdentSerialNumber
OBJECT-TYPE
A character string identifying the serial number of the Charger. This value is set at the factory.
1.3.6.1.4.1.318.1.1.29.1.3DisplayStringread-onlymandatory
chargerIdentModelType
OBJECT-TYPE
The detailed model information of the Charger.
1.3.6.1.4.1.318.1.1.29.1.4DisplayStringread-onlymandatory
chargerInput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.29.2
chargerInputPhaseTable
OBJECT-TYPE
A list of input table entries. The number of entries is given by the sum of the Charger input phases.
1.3.6.1.4.1.318.1.1.29.2.1not-accessiblemandatory
chargerInputPhaseEntry
OBJECT-TYPE
An entry containing information applicable to a particular input phase.
1.3.6.1.4.1.318.1.1.29.2.1.1not-accessiblemandatory
chargerInputPhaseTableIndex
OBJECT-TYPE
The input identifier.
1.3.6.1.4.1.318.1.1.29.2.1.1.1INTEGERread-onlymandatory
chargerInputPhaseVoltage
OBJECT-TYPE
The input voltage in VAC, or -1 if it's unsupported by this Charger.
1.3.6.1.4.1.318.1.1.29.2.1.1.2INTEGERread-onlymandatory
chargerInputPhaseMinVoltage
OBJECT-TYPE
The lowest input voltage to the Charger during the previous minute of operation, or -1 if it's unsupported by this Charger.
1.3.6.1.4.1.318.1.1.29.2.1.1.3INTEGERread-onlymandatory
chargerInputPhaseMaxVoltage
OBJECT-TYPE
The highest input voltage to the Charger during the previous minute of operation, or -1 if it's unsupported by this Charger.
1.3.6.1.4.1.318.1.1.29.2.1.1.4INTEGERread-onlymandatory
chargerInputPhaseCurrent
OBJECT-TYPE
The input current in 0.1 amperes, or -1 if it's unsupported by this Charger.
1.3.6.1.4.1.318.1.1.29.2.1.1.5INTEGERread-onlymandatory
chargerOutput
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.29.3
chargerOutputStatus
OBJECT-TYPE
The current state of the Charger. If the Charger is unable to determine the state of the Charger this variable is set to unknown(1).
1.3.6.1.4.1.318.1.1.29.3.1INTEGER {unknown(1), initialising(2), standby(3), onBattery(4), floatCharging(5), boostCharging(6), initialCharging(7)}read-onlymandatory
chargerOutputVauxVoltage
OBJECT-TYPE
The Load output voltage, measured in VDC.
1.3.6.1.4.1.318.1.1.29.3.2Gaugeread-onlymandatory
chargerOutputTotalCurrent
OBJECT-TYPE
The current in amperes drawn by the load on the Charger.
1.3.6.1.4.1.318.1.1.29.3.3Gaugeread-onlymandatory
chargerOutputLoad
OBJECT-TYPE
The current Charger load expressed in percent of the total rated current of the charger.
1.3.6.1.4.1.318.1.1.29.3.4Gaugeread-onlymandatory
ePDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.30
ePDUDeviceStatusTableSize
OBJECT-TYPE
The total number of Easy PDUs
1.3.6.1.4.1.318.1.1.30.1INTEGERread-onlymandatory
ePDUDevice
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.30.2
ePDUDeviceStatusTable
OBJECT-TYPE
A table of Easy PDU status information
1.3.6.1.4.1.318.1.1.30.2.1not-accessiblemandatory
ePDUDeviceStatusEntry
OBJECT-TYPE
Status information from the Easy PDU being queried
1.3.6.1.4.1.318.1.1.30.2.1.1not-accessiblemandatory
ePDUDeviceStatusIndex
OBJECT-TYPE
The index to the Easy PDU status table entry
1.3.6.1.4.1.318.1.1.30.2.1.1.1INTEGERread-onlymandatory
ePDUDeviceStatusModule
OBJECT-TYPE
The user-defined Rack PDU numeric ID
1.3.6.1.4.1.318.1.1.30.2.1.1.2INTEGERread-onlymandatory
ePDUDeviceStatusVersion
OBJECT-TYPE
The Easy PDU firmware and hardware version
1.3.6.1.4.1.318.1.1.30.2.1.1.3DisplayStringread-onlymandatory
ePDUDeviceStatusModelNumber
OBJECT-TYPE
The Easy PDU model number
1.3.6.1.4.1.318.1.1.30.2.1.1.4DisplayStringread-onlymandatory
ePDUDeviceStatusSerialNumber
OBJECT-TYPE
The Easy PDU serial number
1.3.6.1.4.1.318.1.1.30.2.1.1.5DisplayStringread-onlymandatory
ePDUDeviceStatusNumPhases
OBJECT-TYPE
The number of phases present in the Easy PDU
1.3.6.1.4.1.318.1.1.30.2.1.1.6INTEGERread-onlymandatory
ePDUDeviceStatusActivePower
OBJECT-TYPE
Indicates the PDU Active Power. Units:1 Watt. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.2.1.1.7INTEGERread-onlymandatory
ePDUDeviceStatusReactivePower
OBJECT-TYPE
Indicates the PDU Reactive Power. Units:1 Var. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.2.1.1.8INTEGERread-onlymandatory
ePDUDeviceStatusApparentPower
OBJECT-TYPE
Indicates the PDU Apparent Power. Units:1 VA. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.2.1.1.9INTEGERread-onlymandatory
ePDUDeviceStatusPowerFactor
OBJECT-TYPE
Indicates the PDU Power Factor. Units:0.1%. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.2.1.1.10INTEGERread-onlymandatory
ePDUDeviceStatusEnergy
OBJECT-TYPE
Indicates the PDU Energy. Units:1 Wh. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.2.1.1.11INTEGERread-onlymandatory
ePDUDeviceStatusFrequency
OBJECT-TYPE
Indicates the PDU Frequency. Units:0.001 Hz. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.2.1.1.12INTEGERread-onlymandatory
ePDUDeviceControlTable
OBJECT-TYPE
A table of Easy PDU control data
1.3.6.1.4.1.318.1.1.30.2.2not-accessiblemandatory
ePDUDeviceControlEntry
OBJECT-TYPE
Control data from Easy PDU being queried
1.3.6.1.4.1.318.1.1.30.2.2.1not-accessiblemandatory
ePDUDeviceControlIndex
OBJECT-TYPE
The index to the Easy PDU control table entry
1.3.6.1.4.1.318.1.1.30.2.2.1.1INTEGERread-onlymandatory
ePDUDeviceControlModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID
1.3.6.1.4.1.318.1.1.30.2.2.1.2INTEGERread-onlymandatory
ePDUDeviceControlReboot
OBJECT-TYPE
Setting this OID to reboot (1) will cause the device reboot immediately. Getting this OID in models that support this feature will do nothing and return the noOperation(0) value.
1.3.6.1.4.1.318.1.1.30.2.2.1.3INTEGER {noOperation(0), reboot(1)}read-writemandatory
ePDUDeviceControlEngeryReset
OBJECT-TYPE
Setting this OID to reboot (1) will cause the device reboot immediately. Getting this OID in models that support this feature will do nothing and return the noOperation(0) value.
1.3.6.1.4.1.318.1.1.30.2.2.1.4INTEGER {noOperation(0), reset(1)}read-writemandatory
ePDUDeviceControlBeepAlarm
OBJECT-TYPE
User-defined Beep alarm, 1 for turn off Beep, 2 for turn on Beep. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.2.2.1.5INTEGER {off(1), on(2)}read-writemandatory
ePDUPhaseTableSize
OBJECT-TYPE
The number of connected Easy PDU phases
1.3.6.1.4.1.318.1.1.30.3INTEGERread-onlymandatory
ePDUPhase
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.30.4
ePDUPhaseConfigTable
OBJECT-TYPE
A table of Easy PDU phase configuration data
1.3.6.1.4.1.318.1.1.30.4.1not-accessiblemandatory
ePDUPhaseConfigEntry
OBJECT-TYPE
Configuration data from currently queried Easy PDU phase
1.3.6.1.4.1.318.1.1.30.4.1.1not-accessiblemandatory
ePDUPhaseConfigIndex
OBJECT-TYPE
The index to the Easy PDU phase configuration table entry
1.3.6.1.4.1.318.1.1.30.4.1.1.1INTEGERread-onlymandatory
ePDUPhaseConfigModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID
1.3.6.1.4.1.318.1.1.30.4.1.1.2INTEGERread-onlymandatory
ePDUPhaseConfigNumber
OBJECT-TYPE
The numeric phase ID
1.3.6.1.4.1.318.1.1.30.4.1.1.3INTEGERread-onlymandatory
ePDUPhaseConfigOverVoltageThreshold
OBJECT-TYPE
User-defined Phase Over Voltage alarm threshold. Units:0.1 V. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.4.1.1.4INTEGERread-writemandatory
ePDUPhaseConfigLowVoltageThreshold
OBJECT-TYPE
User-defined Phase Low Voltage alarm threshold. Units:0.1 V. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.4.1.1.5INTEGERread-writemandatory
ePDUPhaseConfigOverCurrentThreshold
OBJECT-TYPE
User-defined Phase Over Current alarm threshold. Units:0.01 A. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.4.1.1.6INTEGERread-writemandatory
ePDUPhaseConfigLowCurrentThreshold
OBJECT-TYPE
User-defined Phase Low Current alarm threshold. Units:0.01 A. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.4.1.1.7INTEGERread-writemandatory
ePDUPhaseStatusTable
OBJECT-TYPE
A table of Rack PDU phase status data
1.3.6.1.4.1.318.1.1.30.4.2not-accessiblemandatory
ePDUPhaseStatusEntry
OBJECT-TYPE
Status data from currently queried Easy PDU phase
1.3.6.1.4.1.318.1.1.30.4.2.1not-accessiblemandatory
ePDUPhaseStatusIndex
OBJECT-TYPE
The index to the Easy PDU phase configuration table entry
1.3.6.1.4.1.318.1.1.30.4.2.1.1INTEGER (1..12)read-onlymandatory
ePDUPhaseStatusModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID
1.3.6.1.4.1.318.1.1.30.4.2.1.2INTEGERread-onlymandatory
ePDUPhaseStatusNumber
OBJECT-TYPE
The numeric phase ID
1.3.6.1.4.1.318.1.1.30.4.2.1.3INTEGERread-onlymandatory
ePDUPhaseStatusVoltage
OBJECT-TYPE
Indicates the Phase Voltage. Units:0.1 V
1.3.6.1.4.1.318.1.1.30.4.2.1.4INTEGERread-onlymandatory
ePDUPhaseStatusCurrent
OBJECT-TYPE
Indicates the Phase Current. Units:0.01 A
1.3.6.1.4.1.318.1.1.30.4.2.1.5INTEGERread-onlymandatory
ePDUPhaseStatusActivePower
OBJECT-TYPE
Indicates the Phase Active Power. Units:1 Watt
1.3.6.1.4.1.318.1.1.30.4.2.1.6INTEGERread-onlymandatory
ePDUPhaseStatusReactivePower
OBJECT-TYPE
Indicates the Phase Reactive Power. Units:1 Var. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.4.2.1.7INTEGERread-onlymandatory
ePDUPhaseStatusApparentPower
OBJECT-TYPE
Indicates the Phase Apparent Power. Units:1 VA. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.4.2.1.8INTEGERread-onlymandatory
ePDUPhaseStatusPowerFactor
OBJECT-TYPE
Indicates the Phase Power Factor. Units:0.1%
1.3.6.1.4.1.318.1.1.30.4.2.1.9INTEGERread-onlymandatory
ePDUPhaseStatusEnergy
OBJECT-TYPE
Indicates the Phase Energy. Units:1 Wh
1.3.6.1.4.1.318.1.1.30.4.2.1.10INTEGERread-onlymandatory
ePDUOutletTableSize
OBJECT-TYPE
The number of switched outlets on connected Easy PDUs.
1.3.6.1.4.1.318.1.1.30.5INTEGERread-onlymandatory
ePDUOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.30.6
ePDUOutletStatusTable
OBJECT-TYPE
The number of switched outlets on connected Rack PDUs
1.3.6.1.4.1.318.1.1.30.6.1not-accessiblemandatory
ePDUOutletStatusEntry
OBJECT-TYPE
Switched Outlet status from currently queried Easy PDU switched outlet
1.3.6.1.4.1.318.1.1.30.6.1.1not-accessiblemandatory
ePDUOutletStatusIndex
OBJECT-TYPE
The index to the Easy PDU switched outlet status information table entry. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.1.1.1INTEGER (1..128)read-onlymandatory
ePDUOutletStatusModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.1.1.2INTEGERread-onlymandatory
ePDUOutletStatusNumber
OBJECT-TYPE
The numeric switched outlet ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.1.1.3INTEGERread-onlymandatory
ePDUOutletStatusState
OBJECT-TYPE
Indicates the present switch state of the Easy PDU switched outlet being queried. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.1.1.4INTEGER {off(1), on(2)}read-onlymandatory
ePDUOutletControlTable
OBJECT-TYPE
A table of Easy PDU switched outlet control data
1.3.6.1.4.1.318.1.1.30.6.2not-accessiblemandatory
ePDUOutletControlEntry
OBJECT-TYPE
Control data for currently queried Easy PDU switched outlet
1.3.6.1.4.1.318.1.1.30.6.2.1not-accessiblemandatory
ePDUOutletControlIndex
OBJECT-TYPE
The index to the Easy PDU switched outlet configuration table entry. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.2.1.1INTEGER (1..128)read-onlymandatory
ePDUOutletControlModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.2.1.2INTEGERread-onlymandatory
ePDUOutletControlNumber
OBJECT-TYPE
The numeric switched outlet ID. Models that do not support this feature, will respond to this OID with a value of notSupported (-1).
1.3.6.1.4.1.318.1.1.30.6.2.1.3INTEGERread-onlymandatory
ePDUOutletControlCommand
OBJECT-TYPE
Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (3) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Models that do not support this feature, will respond to this OID with a value of notSupported (-1). Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off.
1.3.6.1.4.1.318.1.1.30.6.2.1.4INTEGER {immediateOn(1), immediateOff(2), outletUnknown(3)}read-writemandatory
ePDUSensorTableSize
OBJECT-TYPE
The number of connected temperature-humidity sensors
1.3.6.1.4.1.318.1.1.30.7INTEGERread-onlymandatory
ePDUSensor
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.1.30.8
ePDUSensorConfigTable
OBJECT-TYPE
A table of temperature-humidity sensor configuration data
1.3.6.1.4.1.318.1.1.30.8.1not-accessiblemandatory
ePDUSensorConfigEntry
OBJECT-TYPE
Configuration data from temperature-humidity sensor being queried
1.3.6.1.4.1.318.1.1.30.8.1.1not-accessiblemandatory
ePDUSensorConfigIndex
OBJECT-TYPE
The index to the temperature-humidity sensor configuration data table entry
1.3.6.1.4.1.318.1.1.30.8.1.1.1INTEGERread-onlymandatory
ePDUSensorConfigModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID
1.3.6.1.4.1.318.1.1.30.8.1.1.2INTEGERread-onlymandatory
ePDUSensorConfigTempMaxThreshold
OBJECT-TYPE
User-defined Max Temperature alarm threshold. Units: 0.1 degrees Celsius. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.8.1.1.3INTEGERread-writemandatory
ePDUSensorConfigTempMinThreshold
OBJECT-TYPE
User-defined Min Temperature alarm threshold. Units: 0.1 degrees Celsius. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.8.1.1.4INTEGERread-writemandatory
ePDUSensorConfigHumidityMaxThreshold
OBJECT-TYPE
User-defined Max Humidity alarm threshold. Units: 0.1% relative humidity. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.8.1.1.5INTEGERread-writemandatory
ePDUSensorConfigHumidityMinThreshold
OBJECT-TYPE
User-defined Min Humidity alarm threshold. Units: 0.1% relative humidity. Models that do not support this feature will respond to this OID with a value of -1.
1.3.6.1.4.1.318.1.1.30.8.1.1.6INTEGERread-writemandatory
ePDUSensorStatusTable
OBJECT-TYPE
A table of temperature-humidity sensor status data
1.3.6.1.4.1.318.1.1.30.8.2not-accessiblemandatory
ePDUSensorStatusEntry
OBJECT-TYPE
Status information from temperature-humidity sensor being queried
1.3.6.1.4.1.318.1.1.30.8.2.1not-accessiblemandatory
ePDUSensorStatusIndex
OBJECT-TYPE
The index to the temperature-humidity status data table entry
1.3.6.1.4.1.318.1.1.30.8.2.1.1INTEGER (1..4)read-onlymandatory
ePDUSensorStatusModule
OBJECT-TYPE
The user-defined Easy PDU numeric ID
1.3.6.1.4.1.318.1.1.30.8.2.1.2INTEGERread-onlymandatory
ePDUSensorStatusTemperature
OBJECT-TYPE
Sensor temperature reading in tenths of degrees Celsius.
1.3.6.1.4.1.318.1.1.30.8.2.1.3INTEGERread-onlymandatory
ePDUSensorStatusHumidity
OBJECT-TYPE
Sensor humidity reading in 0.1 percent relative humidity.
1.3.6.1.4.1.318.1.1.30.8.2.1.4INTEGERread-onlymandatory
software
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2
powerNetSubAgent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.1
powerNetSoftwareSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.1.1
powerNetSoftwareSystemDescription
OBJECT-TYPE
A brief description of the PowerNet sub-agent.
1.3.6.1.4.1.318.1.2.1.1.1DisplayString (SIZE(0..79))read-onlymandatory
powerNetSoftwareOid
OBJECT-TYPE
The object identifier of the PowerNet sub-agent.
1.3.6.1.4.1.318.1.2.1.1.2OBJECT IDENTIFIERread-onlymandatory
powerNetSoftwareSystemUpTime
OBJECT-TYPE
The time that the sub-agent has been running.
1.3.6.1.4.1.318.1.2.1.1.3TimeTicksread-onlymandatory
powerNetSoftwareConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.1.2
powerNetSoftwareTableSize
OBJECT-TYPE
The number of software modules supporting the UPS.
1.3.6.1.4.1.318.1.2.1.2.1INTEGERread-onlymandatory
powerNetSoftwareTable
OBJECT-TYPE
A list of the software monitoring the UPS.
1.3.6.1.4.1.318.1.2.1.2.2not-accessiblemandatory
powerNetSoftwareEntry
OBJECT-TYPE
An entry containing information on a software module.
1.3.6.1.4.1.318.1.2.1.2.2.1not-accessiblemandatory
moduleNumber
OBJECT-TYPE
The index into the Software Entry Table
1.3.6.1.4.1.318.1.2.1.2.2.1.1INTEGERread-onlymandatory
moduleName
OBJECT-TYPE
The name of the software module.
1.3.6.1.4.1.318.1.2.1.2.2.1.2DisplayString (SIZE(0..79))read-onlymandatory
moduleVersion
OBJECT-TYPE
The version of the software module.
1.3.6.1.4.1.318.1.2.1.2.2.1.3DisplayString (SIZE(0..8))read-onlymandatory
moduleDate
OBJECT-TYPE
The date of the software module represented as mm-dd-yy.
1.3.6.1.4.1.318.1.2.1.2.2.1.4DisplayString (SIZE(0..9))read-onlymandatory
struxureWareOperations
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.2
struxureWareOperationsStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.2.1
serverStatus
OBJECT-TYPE
The status of the StruxureWare Operations server: 1: The status of the application server is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Restart the StruxureWare DC Operation server. If the server was part of a cluster, see the StruxureWare DC Operation User Assistance about rejoining the cluster. If the problem persists, contact Technical Support. 3: No problem. 4: High availability is lost. The StruxureWare DC Operation Application server is running but one or more nodes are not available. If the StruxureWare DC Operation server is part of a cluster, ensure all nodes are running and there is a network connection between the nodes. If the problem persists, contact Technical Support. 5: Wait for the StruxureWare DC Operation Application server to initialize. If the problem persists, contact Technical Support. 6: Wait for the StruxureWare DC Operation Application server to finish starting. If the problem persists, contact Technical Support. 7: This node is running in Disaster Recovery mode. 8: The JBoss postoffice is currently inconsistent. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support. 9: The JBoss is missing jgroups. This may be a temporary issue. If the problem persists for more than 10 minutes, contact Technical Support.
1.3.6.1.4.1.318.1.2.2.1.1INTEGER {unknown(1), stopped(2), running(3), running-missing(4), initializing(5), starting(6), disaster-recovery(7), postoffice-inconsistent(8), missing-jgroups(9)}read-onlymandatory
databaseStatus
OBJECT-TYPE
The status of the StruxureWare Operations database: 1: The status of the database is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Restart the StruxureWare DC Operation server. If the server was part of a cluster, see the StruxureWare DC Operation User Assistance about rejoining the cluster. If the problem persists, contact Technical Support. 3: No problem. 4: High availability is lost. The database is detached from the cluster and does not receive updates. See the StruxureWare DC Operation User Assistance about reattaching the database node to the StruxureWare DC Operation cluster. If the problem persists, contact Technical Support. 5: The database is catching up with the cluster. Wait for the StruxureWare DC Operation database to retrieve all updates from the master node. If the problem persists, contact Technical Support. 6: The database is attaching to the cluster. Wait for the StruxureWare Operation database to attach to the cluster. If the problem persists, contact Technical Support. 7: The database is the master in a cluster. 8: The database is the primary slave in the cluster. All changes on master are synchronously replicated to this node. 9: The database is a secondary slave in the cluster. All changes on master are asynchronously replicated to this node. 10: The database does not replicate its changes to other nodes.
1.3.6.1.4.1.318.1.2.2.1.2INTEGER {unknown(1), stopped(2), running(3), detached(4), catching-up(5), attaching(6), running-master(7), running-primary-slave(8), running-slave(9), running-alone(10)}read-onlymandatory
loadBalancerStatus
OBJECT-TYPE
The status of the StruxureWare Operations load balancer: 1: Load Balancer status is unknown. Check Webmin and if the problem persists, contact Technical Support. 2: Load Balancer stopped. Restart the StruxureWare DC Operation server. If the problem persists, contact Technical Support. 3: Normal status 4: High availability is lost. The StruxureWare DC Operation Load Balancer is running but one or more nodes are not available. If the StruxureWare DC Operation server is part of a cluster, ensure all nodes are running and there is a network connection between the nodes. If the problem persists, contact Technical Support.
1.3.6.1.4.1.318.1.2.2.1.3INTEGER {unknown(1), stopped(2), running(3), running-missing(4)}read-onlymandatory
essentialServicesStatus
OBJECT-TYPE
The status of the StruxureWare Operations essential services: 1: Unknown status. Check Webmin and if the problem persists, contact Technical Support. 2: Essential services are not running on the StruxureWare DC Operation server. Reboot the node and monitor the status page in Webmin. If the problem persists, contact Technical Support. 3: Normal status 4: The time difference between the StruxureWare DC Operation slave and the master node is too big. Correct the time on the slave to match the time on the master. Consider using an NTP server. If the problem persists, contact Technical Support. 5: The last backup that was attempted on the StruxureWare DC Operation server has failed. Make certain that the system can write to the location specified as backup location. This is particularly relevant for network attached storage. If the problem persists, contact Technical Support.
1.3.6.1.4.1.318.1.2.2.1.4INTEGER {unknown(1), stopped(2), running(3), time-sync-problems(4), backup-problems(5)}read-onlymandatory
etlStatus
OBJECT-TYPE
The status of the StruxureWare Operations ETL services: 1: Unknown status. Check the network configuration and the server network settings. If the problem persists, contact Technical Support (http://www.apc.com/go/direct/index.cfm?tag=support). 2: Normal status, 3: ETL Transformations have failed and are subsequently stopped. Investigate the cause of the failure. If the problem persists, contact Technical Support (http://www.apc.com/go/direct/index.cfm?tag=support). 4: ETL Transformations are currently paused. 5: ETL Transformations are currently stopped.
1.3.6.1.4.1.318.1.2.2.1.5INTEGER {unknown(1), running(2), failed(3), paused(4), stopped(5)}read-onlymandatory
powerChuteNetworkShutdown
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3
pcnsIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.1
pcnshostname
OBJECT-TYPE
The hostname of the PCNS instance.
1.3.6.1.4.1.318.1.2.3.1.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsVersion
OBJECT-TYPE
The version of PCNS installed. x.x.x
1.3.6.1.4.1.318.1.2.3.1.2DisplayString (SIZE(0..9))read-onlymandatory
pcnsOS
OBJECT-TYPE
The version of OS PCNS is Installed on.
1.3.6.1.4.1.318.1.2.3.1.3DisplayString (SIZE(0..32))read-onlymandatory
pcnsJavaVersion
OBJECT-TYPE
The version of Java PCNS is running on.
1.3.6.1.4.1.318.1.2.3.1.4DisplayString (SIZE(0..32))read-onlymandatory
pcnsNetworking
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.2
pcnsUIProtocol
OBJECT-TYPE
Web Protocol used to connect to the PCNS UI.
1.3.6.1.4.1.318.1.2.3.2.1INTEGER {http(1), https(2)}read-onlymandatory
pcnsHttpPort
OBJECT-TYPE
Port used for PCNS http UI.
1.3.6.1.4.1.318.1.2.3.2.2INTEGER (0..65535)read-onlymandatory
pcnsHttpsPort
OBJECT-TYPE
Port used for PCNS https UI.
1.3.6.1.4.1.318.1.2.3.2.3INTEGER (0..65535)read-onlymandatory
pcnsNetworkConfig
OBJECT-TYPE
Configuration of the TCP Network.
1.3.6.1.4.1.318.1.2.3.2.4INTEGER {ipV4(1), ipV6(2)}read-onlymandatory
pcnsVirtualInstall
OBJECT-TYPE
Virtualization technology in use by PCNS.
1.3.6.1.4.1.318.1.2.3.2.5INTEGER {none(1), hyper-V(2), vmWare(3), nutanixAHV(4), nutanixESXi(5), simpliVity(6), hyperFlex(7)}read-onlymandatory
pcnsNMC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.3
pcnsMode
OBJECT-TYPE
Configuration mode of the UPS(s) which PCNS is monitoring.
1.3.6.1.4.1.318.1.2.3.3.1INTEGER {single(1), redundant(2), parallel(3), advanced(4)}read-onlymandatory
pcnsNMCPort
OBJECT-TYPE
Port used to connect to all of the Network Management Card(s).
1.3.6.1.4.1.318.1.2.3.3.2INTEGER (0..65535)read-onlymandatory
pcnsNMCProtocol
OBJECT-TYPE
Web Protocol used to connect to all of the Network Management Card(s).
1.3.6.1.4.1.318.1.2.3.3.3INTEGER {http(1), https(2)}read-onlymandatory
pcnsNmcTable
OBJECT-TYPE
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
1.3.6.1.4.1.318.1.2.3.3.4not-accessiblemandatory
pcnsNmcEntry
OBJECT-TYPE
Details of the NMC.
1.3.6.1.4.1.318.1.2.3.3.4.1not-accessiblemandatory
pcnsNmcIndex
OBJECT-TYPE
Index of the NMC within PCNS setup.
1.3.6.1.4.1.318.1.2.3.3.4.1.1Gaugeread-onlymandatory
pcnsNmcAddr
OBJECT-TYPE
The IP address of the NMC.
1.3.6.1.4.1.318.1.2.3.3.4.1.2IpAddressread-onlymandatory
pcnsNmcOutlet
OBJECT-TYPE
The Outlet Group which PCNS is enrolled with on the NMC.
1.3.6.1.4.1.318.1.2.3.3.4.1.3Gaugeread-onlymandatory
pcnsEvents
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4
pcnsPowerFailed
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.1
pcnsPowerFailedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.1.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsPowerFailedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.1.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsPowerFailedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.1.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsPowerFailedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.1.4DisplayStringread-writemandatory
pcnsPowerFailedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.1.5INTEGERread-writemandatory
pcnsPowerFailedEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.1.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsPowerFailedShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.1.7INTEGERread-writemandatory
pcnsPowerRestored
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.2
pcnsPowerRestoredDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.2.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsPowerRestoredEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.2.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsPowerRestoredEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.2.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsPowerRestoredCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.2.4DisplayStringread-writemandatory
pcnsPowerRestoredCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.2.5INTEGERread-writemandatory
pcnsOverload
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.3
pcnsOverloadDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.3.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsOverloadEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.3.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsOverloadEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.3.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsOverloadCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.3.4DisplayStringread-writemandatory
pcnsOverloadCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.3.5INTEGERread-writemandatory
pcnsOverloadEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.3.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsOverloadShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.3.7INTEGERread-writemandatory
pcnsOverloadSolved
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.4
pcnsOverloadSolvedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.4.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsOverloadSolvedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.4.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsOverloadSolvedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.4.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsOverloadSolvedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.4.4DisplayStringread-writemandatory
pcnsOverloadSolvedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.4.5INTEGERread-writemandatory
pcnsRunTimeExceeded
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.5
pcnsRunTimeExceededDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.5.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsRunTimeExceededEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.5.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeExceededEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.5.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeExceededCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.5.4DisplayStringread-writemandatory
pcnsRunTimeExceededCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.5.5INTEGERread-writemandatory
pcnsRunTimeExceededEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.5.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeExceededShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.5.7INTEGERread-writemandatory
pcnsRunTimeWithinRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.6
pcnsRunTimeWithinRangeDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.6.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsRunTimeWithinRangeEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.6.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeWithinRangeEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.6.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeWithinRangeCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.6.4DisplayStringread-writemandatory
pcnsRunTimeWithinRangeCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.6.5INTEGERread-writemandatory
pcnsRunTimeBelowThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.7
pcnsRunTimeBelowThresholdDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.7.1DisplayString (SIZE(0..32))read-onlymandatory
pcnspcnsRunTimeBelowThresholdEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.7.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeBelowThresholdEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.7.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeBelowThresholdCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.7.4DisplayStringread-writemandatory
pcnsRunTimeBelowThresholdEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.7.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeBelowThresholdCommandFileThreshold
OBJECT-TYPE
If the Runtime Remaining falls below this (seconds), the command file will run.
1.3.6.1.4.1.318.1.2.3.4.7.8INTEGERread-writemandatory
pcnsRunTimeBelowThresholdShutdownThreshold
OBJECT-TYPE
If the Runtime Remaining falls below this (seconds), the shutdown will begin.
1.3.6.1.4.1.318.1.2.3.4.7.9INTEGERread-writemandatory
pcnsRunTimeAboveThreshold
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.8
pcnsRunTimeAboveThresholdDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.8.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsRunTimeAboveThresholdEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.8.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeAboveThresholdEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.8.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsRunTimeAboveThresholdCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.8.4DisplayStringread-writemandatory
pcnsRunTimeAboveThresholdCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.8.5INTEGERread-writemandatory
pcnsBatteryDischarged
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.10
pcnsBatteryDischargedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.10.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBatteryDischargedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.10.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBatteryDischargedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.10.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBatteryDischargedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.10.4DisplayStringread-writemandatory
pcnsBatteryDischargedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.10.5INTEGERread-writemandatory
pcnsBatteryDischargedEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.10.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsBatteryDischargedShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.10.7INTEGERread-writemandatory
pcnsBatteryChargeInRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.11
pcnsBatteryChargeInRangeDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.11.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBatteryChargeInRangeEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.11.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBatteryChargeInRangeEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.11.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBatteryChargeInRangeCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.11.4DisplayStringread-writemandatory
pcnsBatteryChargeInRangeCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.11.5INTEGERread-writemandatory
pcnsFaultBypassEnabled
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.12
pcnsFaultBypassEnabledDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.12.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsFaultBypassEnabledEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.12.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsFaultBypassEnabledEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.12.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsFaultBypassEnabledCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.12.4DisplayStringread-writemandatory
pcnsFaultBypassEnabledCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.12.5INTEGERread-writemandatory
pcnsFaultBypassEnabledEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.12.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsFaultBypassEnabledShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.12.7INTEGERread-writemandatory
pcnsBypassEnabled
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.13
pcnsBypassEnabledDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.13.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBypassEnabledEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.13.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassEnabledEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.13.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassEnabledCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.13.4DisplayStringread-writemandatory
pcnsBypassEnabledCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.13.5INTEGERread-writemandatory
pcnsBypassEnabledEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.13.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassEnabledShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.13.7INTEGERread-writemandatory
pcnsBypassManualEnabled
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.14
pcnsBypassManualEnabledDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.14.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBypassManualEnabledEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.14.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassManualEnabledEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.14.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassManualEnabledCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.14.4DisplayStringread-writemandatory
pcnsBypassManualEnabledCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.14.5INTEGERread-writemandatory
pcnsBypassManualEnabledEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.14.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassManualEnabledShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.14.7INTEGERread-writemandatory
pcnsBypassDisabled
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.15
pcnsBypassDisabledDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.15.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBypassDisabledEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.15.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassDisabledEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.15.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassDisabledCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.15.4DisplayStringread-writemandatory
pcnsBypassDisabledCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.15.5INTEGERread-writemandatory
pcnsBypassContactorFailed
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.16
pcnsBypassContactorFailedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.16.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBypassContactorFailedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.16.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassContactorFailedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.16.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassContactorFailedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.16.4DisplayStringread-writemandatory
pcnsBypassContactorFailedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.16.5INTEGERread-writemandatory
pcnsBypassContactorFailedEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.16.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassContactorFailedShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.16.7INTEGERread-writemandatory
pcnsBypassContactorOk
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.17
pcnsBypassContactorOkDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.17.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsBypassContactorOkEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.17.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassContactorOkEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.17.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsBypassContactorOkCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.17.4DisplayStringread-writemandatory
pcnsBypassContactorOkCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.17.5INTEGERread-writemandatory
pcnsCommunicationLostOnBattery
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.18
pcnsCommunicationLostOnBatteryDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.18.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsCommunicationLostOnBatteryEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.18.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationLostOnBatteryEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.18.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationLostOnBatteryCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.18.4DisplayStringread-writemandatory
pcnsCommunicationLostOnBatteryCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.18.5INTEGERread-writemandatory
pcnsCommunicationLostOnBatteryEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.18.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationLostOnBatteryShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.18.7INTEGERread-writemandatory
pcnsCommunicationLost
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.19
pcnsCommunicationLostDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.19.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsCommunicationLostEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.19.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationLostEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.19.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationLostCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.19.4DisplayStringread-writemandatory
pcnsCommunicationLostCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.19.5INTEGERread-writemandatory
pcnsCommunicationLostEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.19.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationLostShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.19.7INTEGERread-writemandatory
pcnsNetCommunicationLost
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.20
pcnsNetCommunicationLostDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.20.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsNetCommunicationLostEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.20.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsNetCommunicationLostEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.20.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsNetCommunicationLostCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.20.4DisplayStringread-writemandatory
pcnsNetCommunicationLostCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.20.5INTEGERread-writemandatory
pcnsNetCommunicationLostEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.20.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsNetCommunicationLostShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.20.7INTEGERread-writemandatory
pcnsCommunicationEstablished
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.21
pcnsCommunicationEstablishedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.21.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsCommunicationEstablishedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.21.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationEstablishedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.21.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsCommunicationEstablishedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.21.4DisplayStringread-writemandatory
pcnsCommunicationEstablishedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.21.5INTEGERread-writemandatory
pcnsMinRedundancyLost
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.22
pcnsMinRedundancyLostDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.22.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsMinRedundancyLostEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.22.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinRedundancyLostEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.22.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinRedundancyLostCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.22.4DisplayStringread-writemandatory
pcnsMinRedundancyLostCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.22.5INTEGERread-writemandatory
pcnsMinRedundancyLostEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.22.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinRedundancyLostShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.22.7INTEGERread-writemandatory
pcnsMinRedundancyRegained
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.23
pcnsMinRedundancyRegainedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.23.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsMinRedundancyRegainedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.23.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinRedundancyRegainedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.23.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinRedundancyRegainedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.23.4DisplayStringread-writemandatory
pcnsMinRedundancyRegainedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.23.5INTEGERread-writemandatory
pcnsParallelRedundancyLost
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.24
pcnsParallelRedundancyLostDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.24.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsParallelRedundancyLostEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.24.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsParallelRedundancyLostEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.24.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsParallelRedundancyLostCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.24.4DisplayStringread-writemandatory
pcnsParallelRedundancyLostCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.24.5INTEGERread-writemandatory
pcnsParallelRedundancyLostEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.24.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsParallelRedundancyLostShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.24.7INTEGERread-writemandatory
pcnsParallelRedundancyRegained
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.25
pcnsParallelRedundancyRegainedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.25.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsParallelRedundancyRegainedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.25.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsParallelRedundancyRegainedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.25.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsParallelRedundancyRegainedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.25.4DisplayStringread-writemandatory
pcnsParallelRedundancyRegainedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.25.5INTEGERread-writemandatory
pcnsMaxInternalTempExceeded
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.26
pcnsMaxInternalTempExceededDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.26.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsMaxInternalTempExceededEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.26.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsMaxInternalTempExceededEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.26.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsMaxInternalTempExceededCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.26.4DisplayStringread-writemandatory
pcnsMaxInternalTempExceededCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.26.5INTEGERread-writemandatory
pcnsMaxInternalTempExceededEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.26.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsMaxInternalTempExceededShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.26.7INTEGERread-writemandatory
pcnsMaxInternalTempInRange
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.27
pcnsMaxInternalTempInRangeDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.27.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsMaxInternalTempInRangeEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.27.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsMaxInternalTempInRangeEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.27.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsMaxInternalTempInRangeCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.27.4DisplayStringread-writemandatory
pcnsMaxInternalTempInRangeCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.27.5INTEGERread-writemandatory
pcnsMinLoadCapabilityLost
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.28
pcnsMinLoadCapabilityLostDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.28.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsMinLoadCapabilityLostEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.28.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinLoadCapabilityLostEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.28.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinLoadCapabilityLostCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.28.4DisplayStringread-writemandatory
pcnsMinLoadCapabilityLostCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.28.5INTEGERread-writemandatory
pcnsMinLoadCapabilityLostEnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.28.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinLoadCapabilityLostShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.28.7INTEGERread-writemandatory
pcnsMinLoadCapabilityRegained
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.29
pcnsMinLoadCapabilityRegainedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.29.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsMinLoadCapabilityRegainedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.29.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinLoadCapabilityRegainedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.29.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsMinLoadCapabilityRegainedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.29.4DisplayStringread-writemandatory
pcnsMinLoadCapabilityRegainedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.29.5INTEGERread-writemandatory
pcnsEnvironmentCommunicationEstablished
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.30
pcnsEnvironmentCommunicationEstablishedDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.30.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsEnvironmentCommunicationEstablishedEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.30.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsEnvironmentCommunicationEstablishedEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.30.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsEnvironmentCommunicationEstablishedCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.30.4DisplayStringread-writemandatory
pcnsEnvironmentCommunicationEstablishedCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.30.5INTEGERread-writemandatory
pcnsEnvironmentCommunicationLost
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.31
pcnsEnvironmentCommunicationLostDesc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.31.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsEnvironmentCommunicationLostEnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.31.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsEnvironmentCommunicationLostEnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.31.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsEnvironmentCommunicationLostCommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.31.4DisplayStringread-writemandatory
pcnsEnvironmentCommunicationLostCommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.31.5INTEGERread-writemandatory
pcnsTempInRangeProbe1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.32
pcnsTempInRangeProbe1Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.32.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsTempInRangeProbe1EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.32.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempInRangeProbe1EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.32.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempInRangeProbe1CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.32.4DisplayStringread-writemandatory
pcnsTempInRangeProbe1CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.32.5INTEGERread-writemandatory
pcnsTempOutOfRangeProbe1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.33
pcnsTempOutOfRangeProbe1Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.33.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsTempOutOfRangeProbe1EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.33.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempOutOfRangeProbe1EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.33.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempOutOfRangeProbe1CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.33.4DisplayStringread-writemandatory
pcnsTempOutOfRangeProbe1CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.33.5INTEGERread-writemandatory
pcnsTempOutOfRangeProbe1EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.33.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempOutOfRangeProbe1ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.33.7INTEGERread-writemandatory
pcnsHumidityInRangeProbe1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.34
pcnsHumidityInRangeProbe1Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.34.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsHumidityInRangeProbe1EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.34.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityInRangeProbe1EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.34.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityInRangeProbe1CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.34.4DisplayStringread-writemandatory
pcnsHumidityInRangeProbe1CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.34.5INTEGERread-writemandatory
pcnsHumidityOutOfRangeProbe1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.35
pcnsHumidityOutOfRangeProbe1Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.35.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsHumidityOutOfRangeProbe1EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.35.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityOutOfRangeProbe1EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.35.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityOutOfRangeProbe1CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.35.4DisplayStringread-writemandatory
pcnsHumidityOutOfRangeProbe1CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.35.5INTEGERread-writemandatory
pcnsHumidityOutOfRangeProbe1EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.35.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityOutOfRangeProbe1ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.35.7INTEGERread-writemandatory
pcnsTempInRangeProbe2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.36
pcnsTempInRangeProbe2Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.36.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsTempInRangeProbe2EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.36.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempInRangeProbe2EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.36.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempInRangeProbe2CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.36.4DisplayStringread-writemandatory
pcnsTempInRangeProbe2CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.36.5INTEGERread-writemandatory
pcnsTempOutOfRangeProbe2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.37
pcnsTempOutOfRangeProbe2Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.37.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsTempOutOfRangeProbe2EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.37.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempOutOfRangeProbe2EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.37.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempOutOfRangeProbe2CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.37.4DisplayStringread-writemandatory
pcnsTempOutOfRangeProbe2CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.37.5INTEGERread-writemandatory
pcnsTempOutOfRangeProbe2EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.37.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsTempOutOfRangeProbe2ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.37.7INTEGERread-writemandatory
pcnsHumidityInRangeProbe2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.38
pcnsHumidityInRangeProbe2Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.38.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsHumidityInRangeProbe2EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.38.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityInRangeProbe2EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.38.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityInRangeProbe2CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.38.4DisplayStringread-writemandatory
pcnsHumidityInRangeProbe2CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.38.5INTEGERread-writemandatory
pcnsHumidityOutOfRangeProbe2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.39
pcnsHumidityOutOfRangeProbe2Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.39.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsHumidityOutOfRangeProbe2EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.39.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityOutOfRangeProbe2EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.39.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityOutOfRangeProbe2CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.39.4DisplayStringread-writemandatory
pcnsHumidityOutOfRangeProbe2CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.39.5INTEGERread-writemandatory
pcnsHumidityOutOfRangeProbe2EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.39.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsHumidityOutOfRangeProbe2ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.39.7INTEGERread-writemandatory
pcnsContactFault1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.40
pcnsContactFault1Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.40.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactFault1EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.40.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault1EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.40.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault1CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.40.4DisplayStringread-writemandatory
pcnsContactFault1CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.40.5INTEGERread-writemandatory
pcnsContactFault1EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.40.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault1ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.40.7INTEGERread-writemandatory
pcnsContactFault2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.41
pcnsContactFault2Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.41.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactFault2EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.41.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault2EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.41.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault2CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.41.4DisplayStringread-writemandatory
pcnsContactFault2CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.41.5INTEGERread-writemandatory
pcnsContactFault2EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.41.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault2ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.41.7INTEGERread-writemandatory
pcnsContactFault3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.42
pcnsContactFault3Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.42.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactFault3EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.42.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault3EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.42.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault3CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.42.4DisplayStringread-writemandatory
pcnsContactFault3CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.42.5INTEGERread-writemandatory
pcnsContactFault3EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.42.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault3ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.42.7INTEGERread-writemandatory
pcnsContactFault4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.43
pcnsContactFault4Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.43.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactFault4EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.43.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault4EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.43.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault4CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.43.4DisplayStringread-writemandatory
pcnsContactFault4CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.43.5INTEGERread-writemandatory
pcnsContactFault4EnableShutdown
OBJECT-TYPE
Perform a graceful shutdown of the server when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.43.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactFault4ShutdownDelay
OBJECT-TYPE
How long to wait after event occurs before performing a graceful shutdown of the server (seconds).
1.3.6.1.4.1.318.1.2.3.4.43.7INTEGERread-writemandatory
pcnsContactNormal1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.44
pcnsContactNormal1Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.44.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactNormal1EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.44.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal1EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.44.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal1CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.44.4DisplayStringread-writemandatory
pcnsContactNormal1CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.44.5INTEGERread-writemandatory
pcnsContactNormal2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.45
pcnsContactNormal2Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.45.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactNormal2EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.45.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal2EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.45.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal2CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.45.4DisplayStringread-writemandatory
pcnsContactNormal2CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.45.5INTEGERread-writemandatory
pcnsContactNormal3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.46
pcnsContactNormal3Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.46.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactNormal3EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.46.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal3EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.46.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal3CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.46.4DisplayStringread-writemandatory
pcnsContactNormal3CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.46.5INTEGERread-writemandatory
pcnsContactNormal4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.4.47
pcnsContactNormal4Desc
OBJECT-TYPE
The Description of the event.
1.3.6.1.4.1.318.1.2.3.4.47.1DisplayString (SIZE(0..32))read-onlymandatory
pcnsContactNormal4EnableLogging
OBJECT-TYPE
Log occurrences of this event in PCNS log.
1.3.6.1.4.1.318.1.2.3.4.47.2INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal4EnableCommandFile
OBJECT-TYPE
Execute a command file when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.47.3INTEGER {yes(1), no(2)}read-writemandatory
pcnsContactNormal4CommandFilePath
OBJECT-TYPE
Path of command file to execute when this event occurs.
1.3.6.1.4.1.318.1.2.3.4.47.4DisplayStringread-writemandatory
pcnsContactNormal4CommandFileDelay
OBJECT-TYPE
How long to wait after event occurs before executing command file (seconds).
1.3.6.1.4.1.318.1.2.3.4.47.5INTEGERread-writemandatory
pcnsShutdown
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.5
pcnsShutdownCommandFileEnabled
OBJECT-TYPE
Run a shutdown command file before performing graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.1INTEGER {yes(1), no(2)}read-writemandatory
pcnsShutdownCommandFileDelay
OBJECT-TYPE
How long in seconds to wait before running a shutdown command file before graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.2INTEGERread-writemandatory
pcnsShutdownCommandFile
OBJECT-TYPE
Full name of the shutdown command file to run before graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.3DisplayStringread-writemandatory
pcnsShutdownCommandFileDuration
OBJECT-TYPE
How long in seconds shutdown command file takes to run.
1.3.6.1.4.1.318.1.2.3.5.4INTEGERread-writemandatory
pcnsTurnOffUps
OBJECT-TYPE
Turn off the UPS when performing a graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.5INTEGER {yes(1), no(2)}read-writemandatory
pcnsTurnOffSOG
OBJECT-TYPE
Turn off the Outlet Group on the UPS when performing a graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.6INTEGER {yes(1), no(2)}read-writemandatory
pcnsRuntimeRemainingThreshold
OBJECT-TYPE
This defines a threshold for runtime remaining. When the UPS is running on battery power and the runtime remaining on the UPS drops below the threshold, PowerChute will trigger a shutdown sequence.
1.3.6.1.4.1.318.1.2.3.5.7INTEGERread-writemandatory
pcnsRuntimeRemainingCmdFileThreshold
OBJECT-TYPE
This defines a threshold for runtime remaining. When runtime remaining drops below this threshold, PowerChute will execute the command file.
1.3.6.1.4.1.318.1.2.3.5.8INTEGERread-writemandatory
pcnsAdvancedShutdownTable
OBJECT-TYPE
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
1.3.6.1.4.1.318.1.2.3.5.9not-accessiblemandatory
pcnsAdvancedShutdownEntry
OBJECT-TYPE
Details of the NMC.
1.3.6.1.4.1.318.1.2.3.5.9.1not-accessiblemandatory
pcnsAdvancedGroupNo
OBJECT-TYPE
Index of the Advanced Shutdown Group.
1.3.6.1.4.1.318.1.2.3.5.9.1.1Gaugeread-onlymandatory
pcnsAdvancedGroupName
OBJECT-TYPE
Name of the Advanced Shutdown Group.
1.3.6.1.4.1.318.1.2.3.5.9.1.2DisplayString (SIZE(0..32))read-writemandatory
pcnsAdvancedGroupNMC
OBJECT-TYPE
List of NMCs in the Advanced Shutdown Group.
1.3.6.1.4.1.318.1.2.3.5.9.1.3DisplayStringread-onlymandatory
pcnsAdvancedShutdownUPSRequiredForLoad
OBJECT-TYPE
Number of UPS's required to power load.
1.3.6.1.4.1.318.1.2.3.5.9.1.4INTEGERread-writemandatory
pcnsAdvancedShutdownCommandFileEnabled
OBJECT-TYPE
Run a shutdown command file before performing graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.9.1.5INTEGER {yes(1), no(2)}read-writemandatory
pcnsAdvancedShutdownCommandFile
OBJECT-TYPE
Full name of the shutdown command file to run before graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.9.1.6DisplayStringread-writemandatory
pcnsAdvancedShutdownCommandFileDuration
OBJECT-TYPE
How long in seconds shutdown command file takes to run.
1.3.6.1.4.1.318.1.2.3.5.9.1.7INTEGERread-writemandatory
pcnsAdvancedShutdownPowerchuteServer
OBJECT-TYPE
Shut down PowerChute Server.
1.3.6.1.4.1.318.1.2.3.5.9.1.8INTEGER {yes(1), no(2)}read-writemandatory
pcnsAdvancedShutdownOnLostRedundancy
OBJECT-TYPE
Shut down if Redundancy lost.
1.3.6.1.4.1.318.1.2.3.5.9.1.9INTEGER {yes(1), no(2)}read-writemandatory
pcnsAdvancedTurnOffUps
OBJECT-TYPE
Turn off the UPS when performing a graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.9.1.10INTEGER {yes(1), no(2)}read-writemandatory
pcnsAdvancedTurnOffSOG
OBJECT-TYPE
Turn off the Outlet Group on the UPS when performing a graceful shutdown.
1.3.6.1.4.1.318.1.2.3.5.9.1.11INTEGER {yes(1), no(2)}read-writemandatory
pcnsAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.3.6
pcnsCriticalFlag
OBJECT-TYPE
PowerChute Network Shutdown has begun a safe shutdown of the host.
1.3.6.1.4.1.318.1.2.3.6.1INTEGER {active(1), clear(2)}read-onlymandatory
pcnsCriticalCause
OBJECT-TYPE
The reason PowerChute Network Shutdown has begun a safe shutdown.
1.3.6.1.4.1.318.1.2.3.6.2DisplayString (SIZE(0..255))read-onlymandatory
pcnsNetComsLostFlag
OBJECT-TYPE
PowerChute cannot communicate with NMC.
1.3.6.1.4.1.318.1.2.3.6.3INTEGER {active(1), clear(2)}read-onlymandatory
pcnsNMCComsLostFlag
OBJECT-TYPE
NMC cannot communicate with UPS.
1.3.6.1.4.1.318.1.2.3.6.4INTEGER {active(1), clear(2)}read-onlymandatory
pcnsUpdateAvailableFlag
OBJECT-TYPE
PowerChute has detected that a newer version is available.
1.3.6.1.4.1.318.1.2.3.6.5INTEGER {active(1), clear(2)}read-onlymandatory
pcnsUpdateDesc
OBJECT-TYPE
Details of the newer version of PowerChute.
1.3.6.1.4.1.318.1.2.3.6.6DisplayString (SIZE(0..255))read-onlymandatory
pcnsLoggingLevel
OBJECT-TYPE
Override the Root Logging level for PCNS. Possible Values: CLEAR, DEBUG
1.3.6.1.4.1.318.1.2.3.7DisplayString (SIZE(0..6))read-writemandatory
powerChuteBusinessEdition
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.4
pcbeIdent
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.4.1
pcbeHostname
OBJECT-TYPE
The hostname of the PCBE instance.
1.3.6.1.4.1.318.1.2.4.1.1DisplayString (SIZE(0..32))read-onlymandatory
pcbeVersion
OBJECT-TYPE
The version of PCBE installed. x.x.x
1.3.6.1.4.1.318.1.2.4.1.2DisplayString (SIZE(0..32))read-onlymandatory
pcbeOS
OBJECT-TYPE
The version of OS PCBE is installed on.
1.3.6.1.4.1.318.1.2.4.1.3DisplayString (SIZE(0..32))read-onlymandatory
pcbeJavaVersion
OBJECT-TYPE
The version of Java PCBE is running on.
1.3.6.1.4.1.318.1.2.4.1.4DisplayString (SIZE(0..32))read-onlymandatory
pcbeUIProtocol
OBJECT-TYPE
Web Protocol used to connect to the PCBE UI.
1.3.6.1.4.1.318.1.2.4.1.5INTEGER {http(1), https(2)}read-onlymandatory
pcbeHttpPort
OBJECT-TYPE
Port used for PCBE http UI.
1.3.6.1.4.1.318.1.2.4.1.6INTEGER (0..65535)read-onlymandatory
pcbeHttpsPort
OBJECT-TYPE
Port used for PCBE https UI.
1.3.6.1.4.1.318.1.2.4.1.7INTEGER (0..65535)read-onlymandatory
pcbeAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.2.4.6
pcbeCriticalFlag
OBJECT-TYPE
PowerChute Business Edition has begun a safe shutdown of the host.
1.3.6.1.4.1.318.1.2.4.6.1INTEGER {active(1), clear(2)}read-onlymandatory
pcbeCriticalCause
OBJECT-TYPE
The reason PowerChute Business Edition has begun a safe shutdown.
1.3.6.1.4.1.318.1.2.4.6.2DisplayString (SIZE(0..255))read-onlymandatory
pcbeComsLostFlag
OBJECT-TYPE
If active (1), PowerChute cannot communicate with UPS
1.3.6.1.4.1.318.1.2.4.6.3INTEGER {active(1), clear(2)}read-onlymandatory
pcbeUpdateAvailableFlag
OBJECT-TYPE
PowerChute has detected that a newer version is available.
1.3.6.1.4.1.318.1.2.4.6.5INTEGER {active(1), clear(2)}read-onlymandatory
pcbeUpdateDesc
OBJECT-TYPE
Details of the newer version of PowerChute.
1.3.6.1.4.1.318.1.2.4.6.6DisplayString (SIZE(0..255))read-onlymandatory
system
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3
backUPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.1
smartUPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2
smartUPS250
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.1
smartUPS400
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.2
smartUPS600
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.3
smartUPS900
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.4
smartUPS1250
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.5
smartUPS2000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.6
smartUPS450
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.7
smartUPS700
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.8
smartUPS1000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.9
smartUPS1400
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.10
smartUPS2200
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.11
smartUPS3000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.12
smartUPS5000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.13
smartUPS7500
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.14
smartUPS10000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.15
smartUPS1500
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.16
smartUPS3000DSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.17
smartUPS5000DSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.18
smartUPS8000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.2.19
matrixUPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.3
matrixUPS3000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.3.1
matrixUPS5000
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.3.2
masterSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4
masterSwitchV1
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.1
masterSwitchV2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.2
masterSwitchVM
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.3
masterSwitchMSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.4
masterSwitchrPDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.5
masterSwitchrPDU2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.6
masterSwitchsPDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.7
masterSwitchrPDUB
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.8
masterSwitchePDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.4.9
symmetraUPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.5
symmetraUPS4kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.5.1
symmetraUPS8kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.5.2
symmetraUPS12kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.5.3
symmetraUPS16kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.5.4
dp100E
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.6
dp300E
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.7
monitors
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.8
environmental
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.8.1
environmentalMgtSystem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.8.2
emu2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.8.3
mem
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.8.4
redundantSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.9
dcPower
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.10
dm3
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.10.1
dcmim2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.10.2
automaticXferSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.11
netLock
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.12
symmetra3PhaseUPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.13
symmetra3PhaseUPS40kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.13.1
symmetra3PhaseUPS60kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.13.2
symmetra3PhaseUPS80kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.13.3
symmetra3PhaseUPS20kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.13.4
networkAir
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14
airFMSeries
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.1
rackAirRemovalUnit
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.2
airPASeries
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.3
airIRSC100Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.4
airIRRC100Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.5
airIRRP100Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.6
airIRRP500Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.7
airIRRD100Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.8
airInRoomPerimeter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.9
airACRC300Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.10
airLESeries
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.11
airIRRDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.12
airEcoBreeze
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.13
airLELSeries
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.14
airACRC600Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.15
airACRD600Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.16
airEconomizer
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.17
airTSAChillers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.18
airLEG2Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.19
airAmico
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.20
airUniflarSP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.21
airTrimChiller
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.22
airACRD300Series
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.14.23
infraStruXurePDU
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.15
ais5000UPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16
ais5000UPS10kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.1
ais5000UPS20kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.2
ais5000UPS30kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.3
ais5000UPS40kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.4
ais5000UPS60kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.5
ais5000UPS80kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.6
ais5000UPS100kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.16.7
smartUPS3Phase
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.17
smartUPS3Phase10kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.17.1
smartUPS3Phase15kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.17.2
smartUPS3Phase20kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.17.3
smartUPS3Phase30kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.17.4
smartUPS3Phase40kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.17.5
battManager
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.18
infraStruXureATS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.19
conPortServ
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.20
conPortServAP930x
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.20.1
gutor
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21
gutorPEW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.1
gutorPDW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.2
gutorWEW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.3
gutorWDW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.4
gutorSDC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.5
gutorPXP
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.6
gutorPXC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.21.7
accControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.22
accPX
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.22.1
symmetraPX
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23
symmetraPx48kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23.1
symmetraPx160kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23.2
symmetraPx250kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23.3
symmetraPx500kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23.4
symmetraPx100kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23.5
symmetraPxDisplay
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.23.6
isxModDistribution
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.24
isx24ModuleHalfRackPdu
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.24.1
isx6ModuleRackPdu
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.24.2
isxServers
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.25
isxcBasic
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.25.1
isxcStandard
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.25.2
isxcEnterprise
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.25.3
isxcVirtual
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.25.4
smartUPS2
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.27
galaxy
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28
galaxy7000UPS200kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.1
galaxy7000UPS250kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.2
galaxy7000UPS300kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.3
galaxy7000UPS400kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.4
galaxy7000UPS500kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.5
galaxy7000SSC800kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.6
galaxy7000SSC1200kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.7
galaxy7000SSC2000kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.8
galaxy300UPS10kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.9
galaxy300UPS15kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.10
galaxy300UPS20kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.11
galaxy300UPS30kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.12
galaxy300UPS40kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.13
galaxy300UPS10kVA31
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.14
galaxy300UPS15kVA31
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.15
galaxy300UPS20kVA31
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.16
galaxy300UPS30kVA31
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.17
galaxy5000UPS20KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.18
galaxy5000UPS30KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.19
galaxy5000UPS40KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.20
galaxy5000UPS50KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.21
galaxy5000UPS60KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.22
galaxy5000UPS80KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.23
galaxy5000UPS100KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.24
galaxy5000UPS120KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.25
galaxy5000UPS130KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.26
galaxy5500UPS20KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.27
galaxy5500UPS30KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.28
galaxy5500UPS40KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.29
galaxy5500UPS50KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.30
galaxy5500UPS60KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.31
galaxy5500UPS80KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.32
galaxy5500UPS100KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.33
galaxy5500UPS120KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.34
galaxy5500UPS130KVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.35
galaxyVMUPS50kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.36
galaxyVMUPS60kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.37
galaxyVMUPS80kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.38
galaxyVMUPS90kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.39
galaxyVMUPS100kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.40
galaxyVMUPS110kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.41
galaxyVMUPS120kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.42
galaxyVMUPS130kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.43
galaxyVMUPS160kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.44
galaxyVMUPS180kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.45
galaxyVMUPS200kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.46
galaxyVMUPS225kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.47
galaxy9000UPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.48
galaxy9000SSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.49
galaxy9000UPSWithSSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.50
galaxy9000FreqConverter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.51
galaxyVXUPS625kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.56
galaxyVXUPS750kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.57
galaxyVXUPS1000kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.58
galaxyVXUPS1250kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.59
galaxyVXUPS1500kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.60
galaxy300UPS60kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.61
galaxy300UPS80kVA33
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.62
galaxyVXUPS500kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.63
galaxyVXUPS250kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.64
galaxyVXUPS400kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.65
galaxyVSUPS100kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.66
galaxy7000UPS160kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.67
galaxyVXUPS300kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.68
galaxyVXUPS1100kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.69
galaxyVSUPS10kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.70
galaxyVSUPS15kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.71
galaxyVSUPS20kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.72
galaxyVSUPS25kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.73
galaxyVSUPS30kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.74
galaxyVSUPS40kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.75
galaxyVSUPS50kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.76
galaxyVSUPS60kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.77
galaxyVSUPS75kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.78
galaxyVSUPS80kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.79
galaxyVSUPS120kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.80
galaxyVSUPS150kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.81
galaxyVXUPS800kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.82
galaxyPXUPS60kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.83
galaxyPXUPS80kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.84
galaxyPXUPS100kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.85
galaxyVLUPS500kW
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.28.86
eps
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30
eps6000UPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.1
eps6000SSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.2
eps6000UPSWithSSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.3
eps6000FreqConverter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.4
eps7000UPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.5
eps7000SSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.6
eps7000UPSWithSSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.7
eps7000FreqConverter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.8
eps8000UPS
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.9
eps8000SSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.10
eps8000UPSWithSSC
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.11
eps8000FreqConverter
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.30.12
pcns
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.31
pcns4
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.31.1
pcbe
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.33
pcbe9
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.33.1
pmm
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.34
pmm400kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.34.1
pmm500kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.34.2
rpp
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.35
rpp400kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.35.1
rpp250kVA
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.3.35.2
experimental
OBJECT-IDENTITY
1.3.6.1.4.1.318.1.4
apcmgmt
OBJECT-IDENTITY
1.3.6.1.4.1.318.2
mconfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.1
mconfigNumTrapReceivers
OBJECT-TYPE
The number of managers to send traps to.
1.3.6.1.4.1.318.2.1.1INTEGERread-onlymandatory
mconfigTrapReceiverTable
OBJECT-TYPE
A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers.
1.3.6.1.4.1.318.2.1.2not-accessiblemandatory
mconfigTrapReceiverEntry
OBJECT-TYPE
The managers to send traps to.
1.3.6.1.4.1.318.2.1.2.1not-accessiblemandatory
trapIndex
OBJECT-TYPE
The index to a trap receiver entry.
1.3.6.1.4.1.318.2.1.2.1.1INTEGERread-onlymandatory
receiverAddr
OBJECT-TYPE
The IP address of the manager to send a trap to.
1.3.6.1.4.1.318.2.1.2.1.2IpAddressread-writemandatory
communityString
OBJECT-TYPE
The community name to use in the trap when sent to the manager.
1.3.6.1.4.1.318.2.1.2.1.3DisplayStringread-writemandatory
severity
OBJECT-TYPE
The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager.
1.3.6.1.4.1.318.2.1.2.1.4INTEGER {information(1), warning(2), severe(3)}read-onlyobsolete
acceptThisReceiver
OBJECT-TYPE
The value of yes(1) indicates that trap generation for this manager is enabled. The value of no(2) indicates that trap generation for this manager is disabled
1.3.6.1.4.1.318.2.1.2.1.5INTEGER {yes(1), no(2)}read-writemandatory
receiveTrapType
OBJECT-TYPE
Type of trap.
1.3.6.1.4.1.318.2.1.2.1.6INTEGER {powernet(1), ietf(2), both(3)}read-onlyobsolete
mconfigBOOTPEnabled
OBJECT-TYPE
The value of yes(1) indicates the PowerNet Adapter is configured to obtain its IP configuration parameters from a BOOTP server. The value of no(2) indicates adapter will assume IP configuration parameters values saved in adapter's eeprom, which was originally configured at local console.
1.3.6.1.4.1.318.2.1.3INTEGER {yes(1), no(2)}read-onlymandatory
mconfigTFTPServerIP
OBJECT-TYPE
The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address is provided by BOOTP server and not allowed to be modified; otherwise, this IP address can be modified. Before using TFTP to load new code image, the image file should be placed in proper directory of the specified TFTP server. This OID is only supported by APC Network Management Cards.
1.3.6.1.4.1.318.2.1.4IpAddressread-writemandatory
newCodeAuthentViaTFTP
OBJECT-TYPE
Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will start to load the remote image file, for authentication only, instead of saving the code into flash memory. Only if a validNewAgentCodeImage (1) is found will the agent reboot the PowerNet adapter and invoke the loader to load and save new code into the flash memory. Otherwise, the current agent code will continue to run. This OID shows the result of the above authentication process. validNewAgentCodeImage (1) means the code image on TFTP server is a valid APC agent code and is different version from the current agent. Once agent identifies this, loader will start to update flash memory with the new agent code. sameAgentCodeImage (2) means the code image on TFTP server is exactly the same as the currently running agent. Currently running agent will not invoke loader to load the same again. invalidAgentCodeImage (3) means the code image on TFTP server is NOT a valid APC agent code. Thus, current agent will not load it into the flash memory. The value of this OID will be associated with TRAP codeImageAuthentDone. This OID is only supported by APC Network Management Cards.
1.3.6.1.4.1.318.2.1.5INTEGER {unknown(1), validNewAgentCodeImage(2), sameAgentCodeImage(3), invalidAgentCodeImage(4)}read-onlymandatory
mconfigClock
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.1.6
mconfigClockDate
OBJECT-TYPE
The current date in the mm/dd/yyyy format. Example: 01/01/2000.
1.3.6.1.4.1.318.2.1.6.1DisplayStringread-writemandatory
mconfigClockTime
OBJECT-TYPE
The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am.
1.3.6.1.4.1.318.2.1.6.2DisplayStringread-writemandatory
mcontrol
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.2
mcontrolRestartAgent
OBJECT-TYPE
Setting this OID to restartCurrentAgent (1) will restart the same SNMP agent code currently saved in flash memory. Setting this OID to loadAndExecuteNewAgent (3) will enable adapter to load a new agent code into the flash memory and start to execute this new agent code. Bootp/tftp is the default protocol. loadAndExecuteNewAgent is only supported by APC Network Management Cards. Setting this OID to restartWithoutAgent (4) will restart the system and not start the agent. The subsequent time the system restarts the agent will also automatically restart. Setting this OID to resetNetworkAndRestart (5) will set the Boot Mode, IP Address, Subnet Mask, and Default Gateway to defaults, expire any existing DHCP lease and then restart the system. Setting this OID to resetNetworkLeaveModeAndRestart (6) will leave the Boot Mode at the current setting, set the IP Address, Subnet Mask, and Default Gateway to defaults, expire any existing DHCP lease and then restart the system.
1.3.6.1.4.1.318.2.2.1INTEGER {restartCurrentAgent(1), continueCurrentAgent(2), loadAndExecuteNewAgent(3), restartWithoutAgent(4), resetNetworkAndRestart(5), resetNetworkLeaveModeAndRestart(6)}read-writemandatory
mtrapargs
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.3
mtrapargsInteger
OBJECT-TYPE
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.1INTEGERread-onlymandatory
mtrapargsIpAddress
OBJECT-TYPE
This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0.
1.3.6.1.4.1.318.2.3.2IpAddressread-onlymandatory
mtrapargsString
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.3SnmpAdminStringread-onlymandatory
mtrapargsGauge
OBJECT-TYPE
This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.4Gaugeread-onlymandatory
mtrapargsTimeTicks
OBJECT-TYPE
This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.5TimeTicksread-onlymandatory
mtrapargsInteger02
OBJECT-TYPE
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.6INTEGERread-onlymandatory
mtrapargsInteger03
OBJECT-TYPE
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.7INTEGERread-onlymandatory
mtrapargsIpAddress02
OBJECT-TYPE
This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0.
1.3.6.1.4.1.318.2.3.8IpAddressread-onlymandatory
mtrapargsIpAddress03
OBJECT-TYPE
This OID allows APC traps to be sent with an IP address argument that my not be defined in the APC MIB. A get of this OID will return 0.0.0.0.
1.3.6.1.4.1.318.2.3.9IpAddressread-onlymandatory
mtrapargsString02
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.10SnmpAdminStringread-onlymandatory
mtrapargsString03
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.11SnmpAdminStringread-onlymandatory
mtrapargsGauge02
OBJECT-TYPE
This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.12Gaugeread-onlymandatory
mtrapargsGauge03
OBJECT-TYPE
This OID allows APC traps to be sent with a Gauge argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.13Gaugeread-onlymandatory
mtrapargsTimeTicks02
OBJECT-TYPE
This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.14TimeTicksread-onlymandatory
mtrapargsTimeTicks03
OBJECT-TYPE
This OID allows APC traps to be sent with a TimeTicks argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.15TimeTicksread-onlymandatory
mtrapargsString04
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.16DisplayStringread-onlymandatory
mtrapargsString05
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.17DisplayStringread-onlymandatory
mtrapargsInteger04
OBJECT-TYPE
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.18INTEGERread-onlymandatory
mtrapargsInteger05
OBJECT-TYPE
This OID allows APC traps to be sent with an integer argument that my not be defined in the APC MIB. A get of this OID will return 0.
1.3.6.1.4.1.318.2.3.19INTEGERread-onlymandatory
mtrapargsString06
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.20DisplayStringread-onlymandatory
mtrapargsString07
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.21DisplayStringread-onlymandatory
mtrapargsString08
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.22DisplayStringread-onlymandatory
mtrapargsOctetString
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.23OCTET STRINGread-onlymandatory
mtrapargsOctetString02
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.24OCTET STRINGread-onlymandatory
mtrapargsOctetString03
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.25OCTET STRINGread-onlymandatory
mtrapargsOctetString04
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.26OCTET STRINGread-onlymandatory
mtrapargsOctetString05
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.27OCTET STRINGread-onlymandatory
mtrapargsOctetString06
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.28OCTET STRINGread-onlymandatory
mtrapargsOctetString07
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.29OCTET STRINGread-onlymandatory
mtrapargsOctetString08
OBJECT-TYPE
This OID allows APC traps to be sent with an octet string argument that my not be defined in the APC MIB. A get of this OID will return a NULL string.
1.3.6.1.4.1.318.2.3.30OCTET STRINGread-onlymandatory
mfiletransfer
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4
mfiletransferStatus
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4.1
mfiletransferStatusLastTransferResult
OBJECT-TYPE
This OID has been deprecated. Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer a file transfer of mfiletransferConfigSettingsFilename will be attempted from either a TFTP or FTP server. This OID shows the last attempted file transfer result. lastFileTransferResultSuccessful (1) means the file transfer was successful. lastFileTransferResultNotAvailable (2) means that there have been no previous file transfers. lastFileTransferResultFailureUnknown (3) means that the last file transfer failed for an unknown reason. lastFileTransferResultFailureServerInaccessible (4) means that the TFTP or FTP server could not be found on the network. lastFileTransferResultFailureServerAccessDenied (5) means that the TFTP or FTP server denied access. lastFileTransferResultFailureFileNotFound (6) means that the file could not be located. lastFileTransferResultFailureFileTypeUnknown (7) means the file was examined, but the contents were unknown. lastFileTransferResultFailureFileCorrupt (8) means the transferred file was corrupt.
1.3.6.1.4.1.318.2.4.1.1INTEGER {lastFileTransferResultSuccessful(1), lastFileTransferResultNotAvailable(2), lastFileTransferResultFailureUnknown(3), lastFileTransferResultFailureServerInaccessible(4), lastFileTransferResultFailureServerAccessDenied(5), lastFileTransferResultFailureFileNotFound(6), lastFileTransferResultFailureFileTypeUnknown(7), lastFileTransferResultFailureFileCorrupted(8)}read-onlydeprecated
mfiletransferConfig
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4.2
mfiletransferConfigSettings
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4.2.1
mfiletransferConfigSettingsFilename
OBJECT-TYPE
This OID has been deprecated. The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID. If the file to transfer exists in the default server directory then the path may be omitted.
1.3.6.1.4.1.318.2.4.2.1.1DisplayStringread-writedeprecated
mfiletransferConfigTFTP
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4.2.2
mfiletransferConfigTFTPServerAddress
OBJECT-TYPE
This OID has been deprecated. The IP Address in dotted decimal notation of the TFTP server involved in the file transfer.
1.3.6.1.4.1.318.2.4.2.2.1DisplayStringread-writedeprecated
mfiletransferConfigFTP
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4.2.3
mfiletransferConfigFTPServerAddress
OBJECT-TYPE
This OID has been deprecated. The IP Address in dotted decimal notation of the FTP server involved in the file transfer.
1.3.6.1.4.1.318.2.4.2.3.1DisplayStringread-writedeprecated
mfiletransferConfigFTPServerUser
OBJECT-TYPE
This OID has been deprecated. The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress.
1.3.6.1.4.1.318.2.4.2.3.2DisplayStringread-writedeprecated
mfiletransferConfigFTPServerPassword
OBJECT-TYPE
This OID has been deprecated. The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress.
1.3.6.1.4.1.318.2.4.2.3.3DisplayStringread-writedeprecated
mfiletransferControl
OBJECT-IDENTITY
1.3.6.1.4.1.318.2.4.3
mfiletransferControlInitiateFileTransfer
OBJECT-TYPE
This OID has been deprecated. Setting this OID to doNotInitiateFileTransfer (1) will do nothing. Setting this OID to initiateFileTransferDownloadViaTFTP (2) will attempt to transfer the file named in mfiletransferConfigSettingsFilename from the TFTP Server identified in mfiletransferConfigTFTPAddress. Setting this OID to initiateFileTransferDownloadViaFTP (3) will attempt to transfer the file named in mfiletransferConfigSettingsFilename from the FTP Server identified in mfiletransferConfigFTPAddress using mfiletransferConfigFTPUser and mfiletransferConfigFTPPassword for the FTP Server login process.
1.3.6.1.4.1.318.2.4.3.1INTEGER {doNotInitiateFileTransfer(1), initiateFileTransferDownloadViaTFTP(2), initiateFileTransferDownloadViaFTP(3)}read-writedeprecated

Notifications

NameOIDStatus
communicationLost
NOTIFICATION-TYPE
SEVERE: Communication to the UPS has been lost. Steps to reestablish communication are in progress.
1.3.6.1.4.1.318.0.1
upsOverload
NOTIFICATION-TYPE
SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity.
1.3.6.1.4.1.318.0.2
upsDiagnosticsFailed
NOTIFICATION-TYPE
SEVERE: The UPS failed its internal diagnostic self-test.
1.3.6.1.4.1.318.0.3
upsDischarged
NOTIFICATION-TYPE
SEVERE: The UPS batteries are discharged; if utility power fails an immediate low battery condition will exist. Sufficient runtime for necessary action cannot be guaranteed.
1.3.6.1.4.1.318.0.4
upsOnBattery
NOTIFICATION-TYPE
WARNING: The UPS has switched to battery backup power.
1.3.6.1.4.1.318.0.5
smartBoostOn
NOTIFICATION-TYPE
WARNING: The UPS has enabled SmartBoost(TM).
1.3.6.1.4.1.318.0.6
lowBattery
NOTIFICATION-TYPE
SEVERE: The UPS batteries are low and will soon be exhausted. If utility power is not restored the UPS will put itself to 'sleep' and immediately cut power to the load.
1.3.6.1.4.1.318.0.7
communicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communication with the UPS has been established.
1.3.6.1.4.1.318.0.8
powerRestored
NOTIFICATION-TYPE
INFORMATIONAL: Utility power has been restored.
1.3.6.1.4.1.318.0.9
upsDiagnosticsPassed
NOTIFICATION-TYPE
INFORMATIONAL: The UPS passed its internal self-test.
1.3.6.1.4.1.318.0.10
returnFromLowBattery
NOTIFICATION-TYPE
INFORMATIONAL: The UPS has returned from a low battery condition.
1.3.6.1.4.1.318.0.11
upsTurnedOff
NOTIFICATION-TYPE
WARNING: The UPS has been turned 'off' by the management station.
1.3.6.1.4.1.318.0.12
upsSleeping
NOTIFICATION-TYPE
WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off.
1.3.6.1.4.1.318.0.13
upsWokeUp
NOTIFICATION-TYPE
INFORMATION: The UPS has returned from 'sleep' mode. Power to the load has been restored.
1.3.6.1.4.1.318.0.14
upsRebootStarted
NOTIFICATION-TYPE
WARNING: The UPS has started its reboot sequence. The UPS will reboot itself at this time.
1.3.6.1.4.1.318.0.15
upsDipSwitchChanged
NOTIFICATION-TYPE
WARNING: The dip switch settings on the UPS have been changed, possibly altering UPS performance.
1.3.6.1.4.1.318.0.16
upsBatteryNeedsReplacement
NOTIFICATION-TYPE
SEVERE: The batteries of the UPS need immediate replacement.
1.3.6.1.4.1.318.0.17
contactFault
NOTIFICATION-TYPE
SEVERE: One of the contacts on the Environmental Monitor has changed from its default position. The first variable is the contact number that is faulted.
1.3.6.1.4.1.318.0.18
contactFaultResolved
NOTIFICATION-TYPE
INFORMATIONAL: A fault on one of the Environmental Monitor contacts has been resolved. The first variable is the contact number that has been resolved.
1.3.6.1.4.1.318.0.19
hardwareFailureBypass
NOTIFICATION-TYPE
SEVERE: UPS on bypass due to internal fault
1.3.6.1.4.1.318.0.20
softwareBypass
NOTIFICATION-TYPE
WARNING: UPS on bypass - user set via software or panel
1.3.6.1.4.1.318.0.21
switchedBypass
NOTIFICATION-TYPE
WARNING: UPS on bypass - initiated by user
1.3.6.1.4.1.318.0.22
returnFromBypass
NOTIFICATION-TYPE
INFORMATIONAL: UPS has returned from bypass
1.3.6.1.4.1.318.0.23
bypassPowerSupplyFailure
NOTIFICATION-TYPE
SEVERE: Base module bypass power supply needs repair
1.3.6.1.4.1.318.0.24
baseFanFailure
NOTIFICATION-TYPE
SEVERE: Base module fan needs repair
1.3.6.1.4.1.318.0.25
batteryPackCommLost
NOTIFICATION-TYPE
SEVERE: Check installation of external battery packs signal cable
1.3.6.1.4.1.318.0.26
batteryPackCommEstablished
NOTIFICATION-TYPE
INFORMATIONAL: UPS is communicating with the external battery packs.
1.3.6.1.4.1.318.0.27
calibrationStart
NOTIFICATION-TYPE
INFORMATIONAL: A battery calibration test has been initiated on the UPS.
1.3.6.1.4.1.318.0.28
restartAgent
NOTIFICATION-TYPE
INFORMATIONAL: Agent restarting as commanded by manager.
1.3.6.1.4.1.318.0.29
upsTurnedOn
NOTIFICATION-TYPE
INFORMATIONAL: A UPS is turned on.
1.3.6.1.4.1.318.0.30
smartAvrReducing
NOTIFICATION-TYPE
WARNING: The UPS is reducing the line voltage via SmartTrim(TM).
1.3.6.1.4.1.318.0.31
codeAuthenticationDone
NOTIFICATION-TYPE
INFORMATIONAL: Authentication on agent code image is done.
1.3.6.1.4.1.318.0.32
upsOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The overload condition has been cleared.
1.3.6.1.4.1.318.0.33
smartBoostOff
NOTIFICATION-TYPE
INFORMATIONAL: The UPS has returned from SmartBoost(TM).
1.3.6.1.4.1.318.0.34
smartAvrReducingOff
NOTIFICATION-TYPE
INFORMATIONAL: The UPS has returned from SmartTrim(TM).
1.3.6.1.4.1.318.0.35
upsBatteryReplaced
NOTIFICATION-TYPE
INFORMATIONAL: A bad battery fault has been cleared.
1.3.6.1.4.1.318.0.36
calibrationEnd
NOTIFICATION-TYPE
INFORMATIONAL: The UPS has finished calibrating.
1.3.6.1.4.1.318.0.37
dischargeCleared
NOTIFICATION-TYPE
INFORMATIONAL: A UPS discharge condition has been cleared.
1.3.6.1.4.1.318.0.38
gracefulShutdown
NOTIFICATION-TYPE
INFORMATIONAL: A graceful shutdown has been initiated.
1.3.6.1.4.1.318.0.39
outletOn
NOTIFICATION-TYPE
WARNING: The specified PDU outlet has turned on. If sPDUOutletControlIndex equals zero, then all outlets have turned on.
1.3.6.1.4.1.318.0.41
outletOff
NOTIFICATION-TYPE
WARNING: The specified PDU outlet has turned off. If sPDUOutletControlIndex equals zero, then all outlets have turned off.
1.3.6.1.4.1.318.0.42
outletReboot
NOTIFICATION-TYPE
WARNING: The specified PDU outlet has rebooted. If sPDUOutletControlIndex equals zero, then all outlets have rebooted.
1.3.6.1.4.1.318.0.43
configChangeSNMP
NOTIFICATION-TYPE
WARNING: The SNMP configuration has been changed.
1.3.6.1.4.1.318.0.44
configChangeOutlet
NOTIFICATION-TYPE
WARNING: The specified PDU outlet has changed configuration. If sPDUOutletConfigIndex equals zero, then the Master outlet has changed configuration.
1.3.6.1.4.1.318.0.45
accessViolationConsole
NOTIFICATION-TYPE
WARNING: Someone has attempted to login via the console with the incorrect password.
1.3.6.1.4.1.318.0.46
accessViolationHTTP
NOTIFICATION-TYPE
WARNING: Someone has attempted to login via HTTP with the incorrect password.
1.3.6.1.4.1.318.0.47
passwordChange
NOTIFICATION-TYPE
WARNING: The password for the device has been changed.
1.3.6.1.4.1.318.0.48
badVoltage
NOTIFICATION-TYPE
WARNING: The output voltage is not within acceptable range.
1.3.6.1.4.1.318.0.49
badVoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: The output voltage has returned to an acceptable level.
1.3.6.1.4.1.318.0.50
chargerFailure
NOTIFICATION-TYPE
WARNING: The battery charger has failed.
1.3.6.1.4.1.318.0.51
chargerFailureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The battery charger failure condition has been cleared.
1.3.6.1.4.1.318.0.52
batteryOverTemperature
NOTIFICATION-TYPE
WARNING: The battery temperature threshold has been violated.
1.3.6.1.4.1.318.0.53
batteryOverTemperatureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The battery over temperature has been cleared.
1.3.6.1.4.1.318.0.54
smartRelayFault
NOTIFICATION-TYPE
WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault.
1.3.6.1.4.1.318.0.55
smartRelayFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared.
1.3.6.1.4.1.318.0.56
humidityThresholdViolation1
NOTIFICATION-TYPE
SEVERE: Probe 1 humidity threshold violated. The first variable is the current humidity.
1.3.6.1.4.1.318.0.57
humidityThresholdViolationCleared1
NOTIFICATION-TYPE
INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1.
1.3.6.1.4.1.318.0.58
temperatureThresholdViolation1
NOTIFICATION-TYPE
SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1. The first variable is the current temperature.
1.3.6.1.4.1.318.0.59
temperatureThresholdViolationCleared1
NOTIFICATION-TYPE
INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1.
1.3.6.1.4.1.318.0.60
humidityThresholdViolation2
NOTIFICATION-TYPE
SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2. The first variable is the current humidity.
1.3.6.1.4.1.318.0.61
humidityThresholdViolationCleared2
NOTIFICATION-TYPE
INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2.
1.3.6.1.4.1.318.0.62
temperatureThresholdViolation2
NOTIFICATION-TYPE
SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2. The first variable is the current temperature.
1.3.6.1.4.1.318.0.63
temperatureThresholdViolationCleared2
NOTIFICATION-TYPE
INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2.
1.3.6.1.4.1.318.0.64
mupsCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communication with the Environmental Monitor has been established.
1.3.6.1.4.1.318.0.65
mupsCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communication to the Environmental Monitor has been lost. Steps to reestablish communication are in progress.
1.3.6.1.4.1.318.0.66
batteryIncrease
NOTIFICATION-TYPE
INFORMATIONAL: The number of batteries has increased.
1.3.6.1.4.1.318.0.67
batteryDecrease
NOTIFICATION-TYPE
INFORMATIONAL: The number of batteries has decreased.
1.3.6.1.4.1.318.0.68
powerModuleIncrease
NOTIFICATION-TYPE
INFORMATIONAL: The number of power modules has increased.
1.3.6.1.4.1.318.0.69
powerModuleDecrease
NOTIFICATION-TYPE
INFORMATIONAL: The number of power modules has decreased.
1.3.6.1.4.1.318.0.70
intelligenceModuleInserted
NOTIFICATION-TYPE
INFORMATIONAL: An intelligence module has been inserted.
1.3.6.1.4.1.318.0.71
intelligenceModuleRemoved
NOTIFICATION-TYPE
INFORMATIONAL: An intelligence module has been removed.
1.3.6.1.4.1.318.0.72
rintelligenceModuleInserted
NOTIFICATION-TYPE
INFORMATIONAL: A redundant intelligence module has been inserted.
1.3.6.1.4.1.318.0.73
rintelligenceModuleRemoved
NOTIFICATION-TYPE
INFORMATIONAL: A redundant intelligence module has been removed.
1.3.6.1.4.1.318.0.74
extBatteryFrameIncease
NOTIFICATION-TYPE
INFORMATIONAL: An external battery frame has been added.
1.3.6.1.4.1.318.0.75
extBatteryFrameDecrease
NOTIFICATION-TYPE
INFORMATIONAL: An external battery frame has been removed.
1.3.6.1.4.1.318.0.76
abnormalCondition
NOTIFICATION-TYPE
SEVERE: An abnormal condition has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.77
abnormalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: An abnormal condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.78
deviceStatusChange
NOTIFICATION-TYPE
INFORMATIONAL: The status of the device being monitored has changed.
1.3.6.1.4.1.318.0.79
noBatteries
NOTIFICATION-TYPE
WARNING: The UPS has no batteries attached.
1.3.6.1.4.1.318.0.80
noBatteriesCleared
NOTIFICATION-TYPE
INFORMATIONAL: The UPS's batteries have been attached.
1.3.6.1.4.1.318.0.81
userAdded
NOTIFICATION-TYPE
INFORMATIONAL: A new user has been added.
1.3.6.1.4.1.318.0.82
userDeleted
NOTIFICATION-TYPE
INFORMATIONAL: A user has been deleted.
1.3.6.1.4.1.318.0.83
userModified
NOTIFICATION-TYPE
INFORMATIONAL: A user has been modified.
1.3.6.1.4.1.318.0.84
msvmCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communications with the MasterSwitch VM has been established.
1.3.6.1.4.1.318.0.85
msvmCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communications with the MasterSwitch VM has been lost.
1.3.6.1.4.1.318.0.86
msvmOverload
NOTIFICATION-TYPE
SEVERE: The MasterSwitch VM in an overload condition.
1.3.6.1.4.1.318.0.87
msvmOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared.
1.3.6.1.4.1.318.0.88
msvmOutletOn
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on the MasterSwitch VM has turned on.
1.3.6.1.4.1.318.0.89
msvmOutletOff
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on the MasterSwitch VM has turned off.
1.3.6.1.4.1.318.0.90
msvmDeviceConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM.
1.3.6.1.4.1.318.0.91
msvmOutletConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM.
1.3.6.1.4.1.318.0.92
msvmLowLoad
NOTIFICATION-TYPE
INFORMATIONAL: The MasterSwitch VM has violated the low load threshold.
1.3.6.1.4.1.318.0.93
msvmLowLoadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared.
1.3.6.1.4.1.318.0.94
msvmNearOverload
NOTIFICATION-TYPE
SEVERE: The MasterSwitch VM is approaching an overload condition.
1.3.6.1.4.1.318.0.95
msvmNearOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared.
1.3.6.1.4.1.318.0.96
msvmPowerSupplyStatusChange
NOTIFICATION-TYPE
WARNING: The power supply status of the MasterSwitch VM has changed.
1.3.6.1.4.1.318.0.97
mspCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communications with the MasterSwitch plus has been established.
1.3.6.1.4.1.318.0.98
mspCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communications with the MasterSwitch plus has been lost.
1.3.6.1.4.1.318.0.99
mspOutletOn
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on the MasterSwitch plus has turned on.
1.3.6.1.4.1.318.0.100
mspOutletOff
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on the MasterSwitch plus has turned off.
1.3.6.1.4.1.318.0.101
mspDeviceConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus.
1.3.6.1.4.1.318.0.102
mspOutletConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus.
1.3.6.1.4.1.318.0.103
rsSourceSwitched
NOTIFICATION-TYPE
INFORMATIONAL: The Redundant Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the 32-character name of the current source. The third variable is an integer representing the transfer cause: 0=No Transfers Recorded, 1=Due to user action or preferred switching, 3=Due to line notch or spike, 5=Due to low line voltage, 7=Transfer due to high line voltage, 9=Transfer due to frequency out of range. The fourth variable is a character string listing the transfer cause.
1.3.6.1.4.1.318.0.104
rsLostRedundancy
NOTIFICATION-TYPE
SEVERE: The Redundant Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second variable is the 32-character name of the source which is no longer available.
1.3.6.1.4.1.318.0.105
rsRedundancyRestored
NOTIFICATION-TYPE
INFORMATIONAL: Redundancy has been restored to the Redundant Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=B. The second variable is the 32-character name of the source which has been restored.
1.3.6.1.4.1.318.0.106
rsConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A configuration change has been made on a Redundant Switch.
1.3.6.1.4.1.318.0.107
rsCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communications with the Redundant Switch has been established.
1.3.6.1.4.1.318.0.108
rsCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communications with the Redundant Switch has been lost.
1.3.6.1.4.1.318.0.109
dcCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communications with the DC power plant has been established.
1.3.6.1.4.1.318.0.110
dcCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communications with the DC power plant has been lost.
1.3.6.1.4.1.318.0.111
dcPINChanged
NOTIFICATION-TYPE
INFORMATIONAL: The active PIN on the DC controller has been changed.
1.3.6.1.4.1.318.0.112
dcMajorAlarm
NOTIFICATION-TYPE
SEVERE: A Major alarm is active in the DC power plant.
1.3.6.1.4.1.318.0.113
dcMajorAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Major alarm is no longer active in the DC power plant.
1.3.6.1.4.1.318.0.114
dcMinorAlarm
NOTIFICATION-TYPE
WARNING: A Minor alarm is active in the DC power plant.
1.3.6.1.4.1.318.0.115
dcMinorAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Minor alarm is no longer active in the DC power plant.
1.3.6.1.4.1.318.0.116
dcOutputRelayOn
NOTIFICATION-TYPE
WARNING: An output relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the output relay number that has gone on. The second variable is the 16-character name of the output relay.
1.3.6.1.4.1.318.0.117
dcOutputRelayOff
NOTIFICATION-TYPE
INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the output relay number that has gone off. The second variable is the 16-character name of the output relay.
1.3.6.1.4.1.318.0.118
dcInputRelayOn
NOTIFICATION-TYPE
WARNING: An input relay for the powerplant has been activated (state changed to on). The first variable is an integer representing the input relay number that has gone on. The second variable is the 16-character name of the input relay.
1.3.6.1.4.1.318.0.119
dcInputRelayOff
NOTIFICATION-TYPE
INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off). The first variable is an integer representing the input relay number that has gone off. The second variable is the 16-character name of the input relay.
1.3.6.1.4.1.318.0.120
logicPowerSuppliesIncreased
NOTIFICATION-TYPE
INFORMATIONAL: The number of system power supplies has increased.
1.3.6.1.4.1.318.0.121
logicPowerSuppliesDecreased
NOTIFICATION-TYPE
INFORMATIONAL: The number of system power supplies has decreased.
1.3.6.1.4.1.318.0.122
externalSwitchGearClosed
NOTIFICATION-TYPE
INFORMATIONAL: External Switch Gear closed.
1.3.6.1.4.1.318.0.123
externalSwitchGearOpened
NOTIFICATION-TYPE
INFORMATIONAL: External Switch Gear opened.
1.3.6.1.4.1.318.0.124
generalDeviceEvent
NOTIFICATION-TYPE
INFORMATIONAL: APC Device event.
1.3.6.1.4.1.318.0.125
atsSourceSwitched
NOTIFICATION-TYPE
INFORMATIONAL: The Automatic Transfer Switch has switched source. The first variable is an integer representing the current source: 0=A, 1=B. The second variable is the 32-character name of the current source.
1.3.6.1.4.1.318.0.126
atsLostRedundancy
NOTIFICATION-TYPE
SEVERE: The Automatic Transfer Switch has lost redundancy. The first variable is an integer representing the source which is no longer available: 0=A, 1=B. The second variable is the 32-character name of the source which is no longer available.
1.3.6.1.4.1.318.0.127
atsRedundancyRestored
NOTIFICATION-TYPE
INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch . The first variable is an integer representing the source which has been restored: 0=A, 1=B. The second variable is the 32-character name of the source which has been restored.
1.3.6.1.4.1.318.0.128
atsConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch. The first variable is an integer representing the configuration setting which changed: 0=Transfer Voltage Range, 1=Sensitivity, 2=Preferred Source 3=Front Panel Lockout, 4=Current Limit, 5=Reset XA Processor, 6=Reset to defaults, 7=Product Name, 8=Nominal Voltage, 9=Nominal Line Frequency, 10=Narrow VRMS, 11=Medium VRMS, 12=Wide VRMS,13=Frequency Deviation, 14=ColdStart ATS, 15=Events Count Cleared, 16=Phase or Bank Threshold.
1.3.6.1.4.1.318.0.129
atsCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communications with the Automatic Transfer Switch has been established.
1.3.6.1.4.1.318.0.130
atsCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communications with the Automatic Transfer Switch has been lost.
1.3.6.1.4.1.318.0.131
atsOverCurrent
NOTIFICATION-TYPE
SEVERE: Output Current has exceeded threshold. This is same as atsOverload Trap for phase or total in case banked units
1.3.6.1.4.1.318.0.132
atsOverCurrentCleared
NOTIFICATION-TYPE
INFORMATIONAL: Output Current has returned below threshold.This is same as atsOverloadCleared Trap for phase or total in case banked units
1.3.6.1.4.1.318.0.133
atsPowerSupplyFailure
NOTIFICATION-TYPE
SEVERE: The Automatic Transfer Switch Power Supply has failed. The first variable is an integer representing the Power Supply which has failed: 0 = Source A 24V, 1 = 12V, 2 = 5V, 3 = Source B 24V.
1.3.6.1.4.1.318.0.134
atsPowerSupplyFailureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared. The first variable is an integer representing the Power Supply which has cleared: 0 = Source A 24V, 1 = 12V, 2 = 5V, 3 = Source B 24V.
1.3.6.1.4.1.318.0.135
dcMainsFailAlarm
NOTIFICATION-TYPE
WARNING: A Mains Fail alarm is active in the DC power plant.
1.3.6.1.4.1.318.0.136
dcMainsFailAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant.
1.3.6.1.4.1.318.0.137
dcFanFailAlarm
NOTIFICATION-TYPE
WARNING: A Fan Fail alarm is active in the DC power plant.
1.3.6.1.4.1.318.0.138
dcFanFailAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant.
1.3.6.1.4.1.318.0.139
dcRectifierOvertempAlarm
NOTIFICATION-TYPE
WARNING: Rect. Overtemp alarm is active in the power plant.
1.3.6.1.4.1.318.0.140
dcRectifierOvertempAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant.
1.3.6.1.4.1.318.0.141
dcCurrentLimitAlarm
NOTIFICATION-TYPE
WARNING: A Current Limit alarm is active in the power plant.
1.3.6.1.4.1.318.0.142
dcCurrentLimitAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Current Limit alarm is no longer active in the power plant.
1.3.6.1.4.1.318.0.143
dcRectifierFailAlarm
NOTIFICATION-TYPE
WARNING: A Rect. Fail alarm is active in the power plant.
1.3.6.1.4.1.318.0.144
dcRectifierFailAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant.
1.3.6.1.4.1.318.0.145
dcMultRectFailAlarm
NOTIFICATION-TYPE
WARNING: Multiple Rect. Fail alarm is active in the powerplant.
1.3.6.1.4.1.318.0.146
dcMultRectFailAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Multiple Rect Fail alarm is no longer active in the powerplant.
1.3.6.1.4.1.318.0.147
dcBatteryBreakerAlarm
NOTIFICATION-TYPE
WARNING: Batt. Breaker alarm is active in the power plant.
1.3.6.1.4.1.318.0.148
dcBatteryBreakerAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant.
1.3.6.1.4.1.318.0.149
dcRectifierOVPAlarm
NOTIFICATION-TYPE
WARNING: A Rect. OVP alarm is active in the power plant.
1.3.6.1.4.1.318.0.150
dcRectifierOVPAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant.
1.3.6.1.4.1.318.0.151
dcLVDImminentAlarm
NOTIFICATION-TYPE
WARNING: A LVD Imminent alarm is active in the powerplant.
1.3.6.1.4.1.318.0.152
dcLVDImminentAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant.
1.3.6.1.4.1.318.0.153
dcFuseCBAlarm
NOTIFICATION-TYPE
WARNING: A Fuse/CB alarm is active in the DC power plant.
1.3.6.1.4.1.318.0.154
dcFuseCBAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant.
1.3.6.1.4.1.318.0.155
dcBatteryTestFail
NOTIFICATION-TYPE
WARNING: A Battery Test failed in the DC power plant.
1.3.6.1.4.1.318.0.156
dcTemperatureAlarm
NOTIFICATION-TYPE
WARNING: A Temperature is active in the power plant.
1.3.6.1.4.1.318.0.157
dcTemperatureAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Temperature alarm is no longer active in the power plant.
1.3.6.1.4.1.318.0.158
dcHumidityAlarm
NOTIFICATION-TYPE
WARNING: A Humidity alarm is active in the DC power plant.
1.3.6.1.4.1.318.0.159
dcHumidityAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant.
1.3.6.1.4.1.318.0.160
dcBBCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Power plant bridging board communications established.
1.3.6.1.4.1.318.0.161
dcBBCommunicationLost
NOTIFICATION-TYPE
SEVERE: Power plant bridging board communications lost.
1.3.6.1.4.1.318.0.162
iemHighTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: High temperature threshold violated on Integrated Environmental Monitor probe. The first variable is the current temperature. The second variable is the temperature scale. The third variable is the probe number. The fourth variable is the probe name.
1.3.6.1.4.1.318.0.163
iemHighTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High temperature threshold violated on Integrated Environmental Monitor probe has been cleared. The first variable is the probe number. The second variable is the probe name.
1.3.6.1.4.1.318.0.164
iemLowTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: Low temperature threshold violated on integrated probe. The first variable is the current temperature. The second variable is the temperature scale. The third variable is the probe number. The fourth variable is the probe name.
1.3.6.1.4.1.318.0.165
iemLowTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low temperature threshold violated on integrated probe has been cleared. The first variable is the probe number. The second variable is the probe name.
1.3.6.1.4.1.318.0.166
iemHighHumidThresholdViolation
NOTIFICATION-TYPE
SEVERE: High humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third variable is the probe name.
1.3.6.1.4.1.318.0.167
iemHighHumidThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name.
1.3.6.1.4.1.318.0.168
iemLowHumidThresholdViolation
NOTIFICATION-TYPE
SEVERE: Low humidity threshold violated on integrated probe. The first variable is the current humidity. The second variable is the probe number. The third variable is the probe name.
1.3.6.1.4.1.318.0.169
iemLowHumidThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low humidity threshold violated on integrated probe cleared. The first variable is the probe number. The second variable is the probe name.
1.3.6.1.4.1.318.0.170
iemProbeDisconnected
NOTIFICATION-TYPE
WARNING: The temperature/humidity probe on the Integrated Environmental Monitor has been disconnected. This trap is generated when a probe that has been in communication with the Environmental Monitor has been disconnected or can no longer communicate.
1.3.6.1.4.1.318.0.171
iemProbeConnected
NOTIFICATION-TYPE
INFORMATIONAL: The temperature/humidity probe on the Integrated Environmental Monitor has been connected. This trap is generated when the Environmental Monitor establishes communication with a probe that had previously not been connected.
1.3.6.1.4.1.318.0.172
iemContactFault
NOTIFICATION-TYPE
SEVERE: There is a contact fault on the Integrated Environmental Monitor. The first argument is the number of the contact. The second argument is the name of the contact.
1.3.6.1.4.1.318.0.173
iemContactFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The contact fault on the Integrated Environmental Monitor has been cleared. The first argument is the number of the contact. The second argument is the name of the contact.
1.3.6.1.4.1.318.0.174
iemRelayFault
NOTIFICATION-TYPE
SEVERE: The output relay on the Integrated Environmental Monitor has switched to the fault state. The first argument is the number of the output relay. The second argument is the name of the output relay. The third argument is the event that caused the fault.
1.3.6.1.4.1.318.0.175
iemRelayFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The fault condition on the output relay on the Integrated Environmental Monitor has cleared. The first argument is the number of the output relay. The second argument is the name of the output relay.
1.3.6.1.4.1.318.0.176
bmBatManCommEstab
NOTIFICATION-TYPE
INFORMATIONAL: Serial Communications Established with Battery Manager.
1.3.6.1.4.1.318.0.177
bmBatManCommLost
NOTIFICATION-TYPE
SEVERE: Serial Communications Lost with Battery Manager.
1.3.6.1.4.1.318.0.178
bmBatManKneeAlarm
NOTIFICATION-TYPE
SEVERE: Battery Voltage Knee Threshold Alarm Detected.
1.3.6.1.4.1.318.0.179
bmBatManKneeAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared.
1.3.6.1.4.1.318.0.180
bmBatManChargerAlarm
NOTIFICATION-TYPE
WARNING: Charger Alarm Detected.
1.3.6.1.4.1.318.0.181
bmBatManChargerAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Charger Alarm Cleared.
1.3.6.1.4.1.318.0.182
bmBatManBatteryAlarm
NOTIFICATION-TYPE
WARNING: Battery Alarm Detected.
1.3.6.1.4.1.318.0.183
bmBatManBatteryAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Battery Alarm Cleared.
1.3.6.1.4.1.318.0.184
bmBatManEnvironmentAlarm
NOTIFICATION-TYPE
WARNING: Environment Alarm Detected.
1.3.6.1.4.1.318.0.185
bmBatManEnvironmentAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Environment Alarm Cleared.
1.3.6.1.4.1.318.0.186
bmBatManMaintenanceAlarm
NOTIFICATION-TYPE
INFORMATIONAL: Maintenance Alarm Detected.
1.3.6.1.4.1.318.0.187
bmBatManMaintenanceAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Maintenance Alarm Cleared.
1.3.6.1.4.1.318.0.188
pduCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.189
pduCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.190
pduUtilityLineUndervoltage
NOTIFICATION-TYPE
SEVERE: Utility Line Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.191
pduUtilityLineUndervoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: Utility Line Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.192
pduUtilityLineOvervoltage
NOTIFICATION-TYPE
SEVERE: Utility Line Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.193
pduUtilityLineOvervoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: Utility Line Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.194
pduGroundOvercurrent
NOTIFICATION-TYPE
SEVERE: Ground Overcurrent. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.195
pduGroundOvercurrentCleared
NOTIFICATION-TYPE
INFORMATIONAL: Ground Overcurrent Cleared. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.196
pduCircuitPanelInputUndervoltage
NOTIFICATION-TYPE
SEVERE: Circuit Panel Input Undervoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.197
pduCircuitPanelInputUndervoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: Circuit Panel Input Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.198
pduCircuitPanelInputOvervoltage
NOTIFICATION-TYPE
SEVERE: Circuit Panel Input Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.199
pduCircuitPanelInputOvervoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: Circuit Panel Input Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.200
pduCircuitPanelInputUndercurrent
NOTIFICATION-TYPE
SEVERE: Circuit Panel Input Undercurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.201
pduCircuitPanelInputUndercurrentCleared
NOTIFICATION-TYPE
INFORMATIONAL: Circuit Panel Input Undercurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.202
pduCircuitPanelInputOvercurrent
NOTIFICATION-TYPE
SEVERE: Circuit Panel Input Overcurrent. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.203
pduCircuitPanelInputOvercurrentCleared
NOTIFICATION-TYPE
INFORMATIONAL: Circuit Panel Input Overcurrent Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.204
pduCircuitPanelFrequencyOutOfRange
NOTIFICATION-TYPE
SEVERE: Circuit Panel Input Frequency Out Of Range. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.205
pduCircuitPanelFrequencyOutofRangeCleared
NOTIFICATION-TYPE
INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.206
pduCircuitPanelNeutralOvercurrent
NOTIFICATION-TYPE
SEVERE: Circuit Panel Input Neutral Overcurrent. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.207
pduCircuitPanelNeutralOvercurrentCleared
NOTIFICATION-TYPE
INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.208
pduSystemOff
NOTIFICATION-TYPE
SEVERE: PDU System Off. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.209
pduOnBatteryMode
NOTIFICATION-TYPE
SEVERE: PDU is in On Battery Mode. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.210
pduMaintenanceBypassMode
NOTIFICATION-TYPE
INFORMATIONAL: PDU is in Maintenance Bypass Mode. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.211
pduAtypicalBypassMode
NOTIFICATION-TYPE
WARNING: PDU is in Atypical Bypass Mode. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.212
pduNoPanelFeedMode
NOTIFICATION-TYPE
SEVERE: PDU is in No Panel Feed Mode. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.213
pduUpsOperationMode
NOTIFICATION-TYPE
INFORMATIONAL: PDU is in Ups Operation Mode. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.214
pduForcedBypassMode
NOTIFICATION-TYPE
WARNING: PDU is in Forced Bypass Mode. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.215
pduInputTransformerOverTemperature
NOTIFICATION-TYPE
SEVERE: Input Transformer Over Temperature. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.216
pduInputTransformerOverTemperatureCleared
NOTIFICATION-TYPE
INFORMATIONAL: Input Transformer Over Temperature Cleared. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.217
pduUPSInputVoltageLost
NOTIFICATION-TYPE
SEVERE: UPS Input Voltage phase-N Lost. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.218
pduUPSInputVoltageRestored
NOTIFICATION-TYPE
INFORMATIONAL: UPS Input Voltage phase-N Restored. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.219
pduContactFault
NOTIFICATION-TYPE
SEVERE: A contact closure in the PDU is in an abnormal position. The first argument is the serial number. The second argument is the device name. The third argument is the number of the contact.
1.3.6.1.4.1.318.0.220
pduContactFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: A contact closure in the PDU is in a normal position. The first argument is the serial number. The second argument is the device name. The third argument is the number of the contact.
1.3.6.1.4.1.318.0.221
rPDUBankPhaseLowLoad
NOTIFICATION-TYPE
WARNING: A bank or phase on the Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
1.3.6.1.4.1.318.0.222
rPDUBankPhaseLowLoadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
1.3.6.1.4.1.318.0.223
rPDUBankPhaseNearOverload
NOTIFICATION-TYPE
WARNING: A bank or phase of the Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
1.3.6.1.4.1.318.0.224
rPDUBankPhaseNearOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
1.3.6.1.4.1.318.0.225
rPDUBankPhaseOverload
NOTIFICATION-TYPE
SEVERE: A bank or phase of the Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
1.3.6.1.4.1.318.0.226
rPDUBankPhaseOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number (0 if this is phase data). The fourth argument is the phase number (0 if this is bank data).
1.3.6.1.4.1.318.0.227
aruDeviceConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: Remote ARU Device Configuration change. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.228
rmPDUCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.229
emsCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communication Established. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.230
emsCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communication Lost. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.231
emsProbeConnected
NOTIFICATION-TYPE
INFORMATIONAL: A probe has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
1.3.6.1.4.1.318.0.232
emsProbeDisconnected
NOTIFICATION-TYPE
SEVERE: A probe has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
1.3.6.1.4.1.318.0.233
emsSensorConnected
NOTIFICATION-TYPE
INFORMATIONAL: A sensor has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
1.3.6.1.4.1.318.0.234
emsSensorDisconnected
NOTIFICATION-TYPE
SEVERE: A sensor has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
1.3.6.1.4.1.318.0.235
emsSensorFault
NOTIFICATION-TYPE
SEVERE: A EMS sensor is in the fault condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
1.3.6.1.4.1.318.0.236
emsSensorFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: A EMS sensor fault condition has cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the sensor number. The fourth argument is the sensor name.
1.3.6.1.4.1.318.0.237
emsBeaconConnected
NOTIFICATION-TYPE
INFORMATIONAL: A beacon has been connected to the EMS. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.238
emsBeaconDisconnected
NOTIFICATION-TYPE
SEVERE: A beacon has been disconnected from the EMS. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.239
emsBeaconOn
NOTIFICATION-TYPE
INFORMATIONAL: A EMS beacon has gone on. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.240
emsBeaconOff
NOTIFICATION-TYPE
INFORMATIONAL: A EMS beacon has gone off. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.241
emsMajorAlarm
NOTIFICATION-TYPE
SEVERE: A Major Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
1.3.6.1.4.1.318.0.242
emsMajorAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Major Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
1.3.6.1.4.1.318.0.243
emsMinorAlarm
NOTIFICATION-TYPE
SEVERE: A Minor Alarm is present in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
1.3.6.1.4.1.318.0.244
emsMinorAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
1.3.6.1.4.1.318.0.245
emsOutletStateAbnormal
NOTIFICATION-TYPE
WARNING: An outlet on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the outlet number. The fourth argument is the outlet name. The fifth argument is the current outlet state (1=ON, 2=OFF). The sixth argument is the configured normal outlet state (1=ON, 2=OFF).
1.3.6.1.4.1.318.0.246
emsOutletStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the outlet number. The fourth argument is the outlet name. The fifth argument is the current outlet state (1=ON, 2=OFF). The sixth argument is the configured normal outlet state (1=ON, 2=OFF).
1.3.6.1.4.1.318.0.247
emsInputContactStateAbnormal
NOTIFICATION-TYPE
WARNING: An input contact on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.248
emsInputContactStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: An input contact on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.249
emsOutputRelayStateAbnormal
NOTIFICATION-TYPE
WARNING: An output relay on the EMS has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the output relay number. The fourth argument is the output relay name. The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.250
emsOutputRelayStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: An output relay on the EMS has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the output relay number. The fourth argument is the output relay name. The fifth argument is the current output relay state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.251
emsDeviceConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A device configuration change has been made on the EMS. The first argument is the EMS serial number. The second argument is the EMS name.
1.3.6.1.4.1.318.0.252
envHighTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: High temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.253
envHighTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.254
envLowTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: Low temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.255
envLowTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.256
envHighHumidityThresholdViolation
NOTIFICATION-TYPE
SEVERE: High humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.257
envHighHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.258
envLowHumidityThresholdViolation
NOTIFICATION-TYPE
SEVERE: Low humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.259
envLowHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.260
rPDUCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communication with a Rack PDU has been established. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.266
rPDUCommunicationLost
NOTIFICATION-TYPE
SEVERE: Communication with a Rack PDU has been lost. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.267
rPDUOutletOn
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on a Switched Rack PDU has turned on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name.
1.3.6.1.4.1.318.0.268
rPDUOutletOff
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on a Switched Rack PDU has turned off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name.
1.3.6.1.4.1.318.0.269
rPDUDeviceConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A device configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.270
rPDUOutletConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: An outlet configuration change has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name.
1.3.6.1.4.1.318.0.271
rPDULowLoad
NOTIFICATION-TYPE
WARNING: A Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.272
rPDULowLoadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.273
rPDUNearOverload
NOTIFICATION-TYPE
WARNING: A Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.274
rPDUNearOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.275
rPDUOverload
NOTIFICATION-TYPE
SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.276
rPDUOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number.
1.3.6.1.4.1.318.0.277
rPDUPowerSupply1Fail
NOTIFICATION-TYPE
SEVERE: Power Supply 1 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.278
rPDUPowerSupply1Ok
NOTIFICATION-TYPE
INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.279
rPDUPowerSupply2Fail
NOTIFICATION-TYPE
SEVERE: Power Supply 2 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.280
rPDUPowerSupply2Ok
NOTIFICATION-TYPE
INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name.
1.3.6.1.4.1.318.0.281
rPDUPhaseConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A phase configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the phase index number.
1.3.6.1.4.1.318.0.282
rPDUCancelPendingCommand
NOTIFICATION-TYPE
INFORMATIONAL: A cancel pending command has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number (0 indicates all outlets). The fourth argument is the outlet name (or device name if all outlets).
1.3.6.1.4.1.318.0.283
aruAlinkCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Remote ARU Communication Established. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.284
aruAlinkCommunicationLost
NOTIFICATION-TYPE
SEVERE: Remote ARU Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.285
aruFanFail
NOTIFICATION-TYPE
SEVERE: Remote ARU Fan Fail. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.286
aruFanFailCleared
NOTIFICATION-TYPE
INFORMATIONAL: Remote ARU Fan Fail Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.287
aruSmokeAlarm
NOTIFICATION-TYPE
SEVERE: Remote ARU Smoke Alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.288
aruSmokeAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Remote ARU Smoke Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.289
aruHighTemperatureAlarm
NOTIFICATION-TYPE
WARNING: ARU Exhaust temperature has exceeded the override threshold and the ARU has increased fan speed to maintain a safe environment in the rack. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.290
aruHighTemperatureAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: ARU temperature override state has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.291
aruExhaustTemperatureAlarm
NOTIFICATION-TYPE
SEVERE: ARU Extreme Exhaust Temperature Alarm. The ARU is unable to control the temperature within the rack The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.292
aruExhaustTemperatureAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.293
envAlinkCommunicationEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Remote Probe Communication Established. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
1.3.6.1.4.1.318.0.294
envAlinkCommunicationLost
NOTIFICATION-TYPE
SEVERE: Remote Probe Communication Lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the probe number. The fourth argument is the probe name.
1.3.6.1.4.1.318.0.295
emsAlinkPowerOverload
NOTIFICATION-TYPE
SEVERE: Alink Power Overload. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.296
emsAlinkPowerOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: Alink Power Overload Cleared. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.297
upsOutletGroupTurnedOn
NOTIFICATION-TYPE
INFORMATIONAL: The specified Outlet Group turned on.
1.3.6.1.4.1.318.0.298
upsOutletGroupTurnedOff
NOTIFICATION-TYPE
WARNING: The specified Outlet Group turned off.
1.3.6.1.4.1.318.0.299
smwCriticalCondition
NOTIFICATION-TYPE
SEVERE: A Symmetra MW UPS critical condition has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.300
smwCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.301
smwWarningCondition
NOTIFICATION-TYPE
WARNING: A Symmetra MW UPS warning condition has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.302
smwWarningConditionCleared
NOTIFICATION-TYPE
WARNING: A Symmetra MW UPS warning condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.303
smwInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: A Symmetra MW UPS informational condition has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.304
smwInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.305
airCriticalCondition
NOTIFICATION-TYPE
SEVERE: An Air critical condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.306
airCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: An Air critical condition was cleared. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.307
airWarningCondition
NOTIFICATION-TYPE
WARNING: An Air warning condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.308
airWarningConditionCleared
NOTIFICATION-TYPE
WARNING: An Air warning condition was cleared. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.309
airInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: An Air informational condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.310
airInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: An Air informational condition was cleared. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.311
xPDUInputVoltageLowAlarm
NOTIFICATION-TYPE
SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.312
xPDUInputVoltageLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.313
xPDUInputVoltageHighAlarm
NOTIFICATION-TYPE
SEVERE: Three-phase input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated.
1.3.6.1.4.1.318.0.314
xPDUInputVoltageHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.315
xPDUBypassVoltageLowAlarm
NOTIFICATION-TYPE
SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.316
xPDUBypassVoltageLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.317
xPDUBypassVoltageHighAlarm
NOTIFICATION-TYPE
SEVERE: Three-phase bypass input voltage to the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated.
1.3.6.1.4.1.318.0.318
xPDUBypassVoltageHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.319
xPDUOutputVoltageLowAlarm
NOTIFICATION-TYPE
SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.320
xPDUOutputVoltageLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.321
xPDUOutputVoltageHighAlarm
NOTIFICATION-TYPE
SEVERE: The three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated.
1.3.6.1.4.1.318.0.322
xPDUOutputVoltageHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The three-phase output voltage of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.323
xPDUOutputCurrentLowAlarm
NOTIFICATION-TYPE
SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.324
xPDUOutputCurrentLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.325
xPDUOutputCurrentHighAlarm
NOTIFICATION-TYPE
SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated.
1.3.6.1.4.1.318.0.326
xPDUOutputCurrentHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The three-phase output current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.327
xPDUOutputFrequencyAlarm
NOTIFICATION-TYPE
SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the frequency deviation from the nominal in tenths of Hertz.
1.3.6.1.4.1.318.0.328
xPDUOutputFrequencyAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.329
xPDUSystemGroundCurrentAlarm
NOTIFICATION-TYPE
SEVERE: The earth ground current of the device is over the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated.
1.3.6.1.4.1.318.0.330
xPDUSystemGroundCurrentAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The earth ground current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.331
xPDUInputContactStateAbnormal
NOTIFICATION-TYPE
SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
1.3.6.1.4.1.318.0.332
xPDUInputContactStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=CLOSED, 2=OPEN). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
1.3.6.1.4.1.318.0.333
xPDUOutputNeutralCurrentHighAlarm
NOTIFICATION-TYPE
WARNING: The three-phase neutral current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps. The fourth argument is the threshold, in tenths of Amps, above which the alarm was generated.
1.3.6.1.4.1.318.0.334
xPDUOutputNeutralCurrentHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The output neutral current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.335
xPDUCoolingFanAlarm
NOTIFICATION-TYPE
SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.336
xPDUCoolingFanAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The device's cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.337
xPDUTransformerTempAlarm
NOTIFICATION-TYPE
SEVERE: The device's isolation transformer is over temperature. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.338
xPDUTransformerTempAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The device's isolation transformer is no longer over temperature. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.339
xPDUBranchCurrentLowAlarm
NOTIFICATION-TYPE
WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.340
xPDUBranchCurrentLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.341
xPDUBranchCurrentHighAlarm
NOTIFICATION-TYPE
WARNING: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated.
1.3.6.1.4.1.318.0.342
xPDUBranchCurrentHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.343
xPDUInternalCommError
NOTIFICATION-TYPE
SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.344
emsHardwareStateAbnormal
NOTIFICATION-TYPE
SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being connected to the EMS ports or Alink Current limit detection.
1.3.6.1.4.1.318.0.345
emsHardwareStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number.
1.3.6.1.4.1.318.0.346
ceSevereCondition
NOTIFICATION-TYPE
SEVERE: A Custom Event severe condition was detected. The first variable is the custom event text message. The second variable is the custom event number.
1.3.6.1.4.1.318.0.347
ceSevereConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Custom Event severe condition was cleared. The first variable is the custom event text message. The second variable is the custom event number.
1.3.6.1.4.1.318.0.348
ceWarningCondition
NOTIFICATION-TYPE
WARNING: A Custom Event warning condition was detected. The first variable is the custom event text message. The second variable is the custom event number.
1.3.6.1.4.1.318.0.349
ceWarningConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Custom Event warning condition was cleared. The first variable is the custom event text message. The second variable is the custom event number.
1.3.6.1.4.1.318.0.350
ceInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: A Custom Event informational condition was detected. The first variable is the custom event text message. The second variable is the custom event number.
1.3.6.1.4.1.318.0.351
ceInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Custom Event informational condition was cleared. The first variable is the custom event text message. The second variable is the custom event number.
1.3.6.1.4.1.318.0.352
upsInternalOverTemperature
NOTIFICATION-TYPE
WARNING: The internal over temperature condition exists.
1.3.6.1.4.1.318.0.353
upsInternalOverTemperatureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The internal over temperature condition cleared.
1.3.6.1.4.1.318.0.354
upsMpuReset
NOTIFICATION-TYPE
INFORMATIONAL: The MPU has been reset.
1.3.6.1.4.1.318.0.355
upsOutputSwitchClosed
NOTIFICATION-TYPE
INFORMATIONAL: The Output Switch is closed.
1.3.6.1.4.1.318.0.356
upsOutputSwitchOpened
NOTIFICATION-TYPE
INFORMATIONAL: The Output Switch is open.
1.3.6.1.4.1.318.0.357
upsCalibrationStackChanged
NOTIFICATION-TYPE
INFORMATIONAL: A calibration value in the stack was changed.
1.3.6.1.4.1.318.0.358
envMaxTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: Max temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.359
envMaxTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Max temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.360
envMinTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: Min temperature threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.361
envMinTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Min temperature threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.362
envMaxHumidityThresholdViolation
NOTIFICATION-TYPE
SEVERE: Max humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.363
envMaxHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Max humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.364
envMinHumidityThresholdViolation
NOTIFICATION-TYPE
SEVERE: Min humidity threshold violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.365
envMinHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Min humidity threshold violation cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current humidity. The fourth argument is the probe number. The fifth argument is the probe name.
1.3.6.1.4.1.318.0.366
envSTIncTempRateViolation
NOTIFICATION-TYPE
SEVERE: Short-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.367
envSTIncTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Short-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.368
envSTDecTempRateViolation
NOTIFICATION-TYPE
SEVERE: Short-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.369
envSTDecTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.370
envLTIncTempRateViolation
NOTIFICATION-TYPE
SEVERE: Long-term increasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.371
envLTIncTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Long-term increasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.372
envLTDecTempRateViolation
NOTIFICATION-TYPE
SEVERE: Long-term decreasing temperature rate violated on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.373
envLTDecTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe. The first argument is the host device serial number. The second argument is the host device name. The third argument is the current temperature. The fourth argument is the temperature scale. The fifth argument is the probe number. The sixth argument is the probe name.
1.3.6.1.4.1.318.0.374
bmsCriticalCondition
NOTIFICATION-TYPE
SEVERE: A Battery Management System critical condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.375
bmsCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Battery Management System critical condition was cleared. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.376
bmsWarningCondition
NOTIFICATION-TYPE
WARNING: A Battery Management System warning condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.377
bmsWarningConditionCleared
NOTIFICATION-TYPE
WARNING: A Battery Management System warning condition was cleared. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.378
bmsInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: A Battery Management System informational condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.379
bmsInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A Battery Management System informational condition was cleared. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.380
xATSOutputVoltageLowAlarm
NOTIFICATION-TYPE
SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.381
xATSOutputVoltageLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.382
xATSOutputVoltageHighAlarm
NOTIFICATION-TYPE
SEVERE: The device three-phase output voltage of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts. The fifth argument is the threshold, in tenths of Volts, above which the alarm is generated.
1.3.6.1.4.1.318.0.383
xATSOutputVoltageHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The devices three-phase output voltage is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1). The fourth argument is the measured voltage in tenths of Volts.
1.3.6.1.4.1.318.0.384
xATSOutputCurrentLowAlarm
NOTIFICATION-TYPE
SEVERE: The three-phase load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. The fifth argument is the threshold, in Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.385
xATSOutputCurrentLowAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The three-phase load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps.
1.3.6.1.4.1.318.0.386
xATSOutputCurrentHighAlarm
NOTIFICATION-TYPE
SEVERE: The three-phase output load current of the device is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps. The fifth argument is the threshold, in Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.387
xATSOutputCurrentHighAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The three-phase output load current of the device is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3). The fourth argument is the measured current in Amps.
1.3.6.1.4.1.318.0.388
xATSOutputFrequencyAlarm
NOTIFICATION-TYPE
SEVERE: The devices output frequency is outside the specified limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the frequency deviation from the nominal in tenths of Hertz. The fourth argument is the frequency deviation threshold in tenths of Hertz, from which the alarm was generated.
1.3.6.1.4.1.318.0.389
xATSOutputFrequencyAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The devices output frequency is back within the specified limits. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.390
xATSInternalCommError
NOTIFICATION-TYPE
SEVERE: There is an internal communication error in the device. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.391
xATSInternalCommErrorCleared
NOTIFICATION-TYPE
INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.392
xATSDataCommMismatchError
NOTIFICATION-TYPE
SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controller and the Network Management interface. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.393
xATSDataCommMismatchErrorCleared
NOTIFICATION-TYPE
INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.394
xATSGenCommLost
NOTIFICATION-TYPE
WARNING: The XATS cannot communicate with the generator. This will make unavailable all the xATSGenerator OIDs. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.395
xATSGenCommEstablished
NOTIFICATION-TYPE
INFORMATIONAL: The XATS has established communication with the generator. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.396
xATSNeutralPosition
NOTIFICATION-TYPE
WARNING: XATS has transferred to neutral position. In this position neither Source 1 nor Source 2 is selected, and the XATS will have no output voltage. The first argument is the host device serial number. The second argument is the host device name. The third argument is the mode in which the switch is operating (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual).
1.3.6.1.4.1.318.0.397
xATSSwitchTransferEvent
NOTIFICATION-TYPE
INFORMATIONAL: XATS has transferred from one source to the other. The first argument is the host device serial number. The second argument is the host device name. The third argument is the mode in which the switch is operating. (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual). The fourth argument is the input source selected (1=Source 1, 2=Source 2). The fifth argument is type of transfer that took place. (1=Closed, 2=Open, 3=Unknown)
1.3.6.1.4.1.318.0.398
xATSInternalATSFault
NOTIFICATION-TYPE
SEVERE: An internal XATS fault has been detected. The XATS may have forced itself to not-in-auto mode (abnormal condition), as indicated by the xATSSwitchStatusAutoSwitchOperationalMode OID. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the detected fault. 1=Cannot Close S1 2=Cannot Close S2 3=Cannot Open S1 4=Cannot Open S2 5=Cannot Trip Open S1 6=Cannot Trip Open S2 7=Start Contact Failure 8=Voltage Sensing Failure
1.3.6.1.4.1.318.0.399
xATSInternalATSFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected internal XATS fault has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the detected fault. 1=Cannot Close S1 2=Cannot Close S2 3=Cannot Open S1 4=Cannot Open S2 5=Cannot Trip Open S1 6=Cannot Trip Open S2 7=Start Contact Failure 8=Voltage Sensing Failure
1.3.6.1.4.1.318.0.400
xATSEngineStartAsserted
NOTIFICATION-TYPE
INFORMATIONAL: The XATS has asserted the Engine Start contact. This should result in the generator producing output voltage. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the reason that the start signal was asserted 1=Unknown, 2=S1 Low Voltage, 3=S1 High Voltage, 4=S1 Line Imbalance, 5=S1 Freq Range, 6=S1 Bad Rotation.
1.3.6.1.4.1.318.0.401
xATSEngineStopAsserted
NOTIFICATION-TYPE
INFORMATIONAL: The XATS has de-asserted the Engine Start contact. This should result in the generator shutting down, and producing no output voltage. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.402
xATSStartFailure
NOTIFICATION-TYPE
SEVERE: The generator failed to start. After assertion of the Engine Start signal, the quality of Source 2 was not seen as good. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name. The third argument indicates the line quality at S2 1=Unknown, 2=S2 Low Voltage, 3=S2 High Voltage, 4=S2 Line Imbalance, 4=S2 Freq Range, 5=S2 Bad Rotation.
1.3.6.1.4.1.318.0.403
xATSStopFailure
NOTIFICATION-TYPE
WARNING: The generator failed to stop. After de-assertion of the Engine Start signal, the quality of Source 2 continued to be seen as good. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.404
xATSNotInAutomaticMode
NOTIFICATION-TYPE
SEVERE: Automatic Transfer Switch is not in automatic mode. The first argument is the host device serial number. The second argument is the host device name. The xATSSwitchStatusAutoSwitchStatus OID and the xATSSwitchStatusAutoSwitchOperationalMode OID can provide more information about the state of the XATS.
1.3.6.1.4.1.318.0.405
xATSNotInAutomaticModeCleared
NOTIFICATION-TYPE
INFORMATIONAL: Automatic Transfer Switch is in automatic mode. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.406
xATSEpoTripped
NOTIFICATION-TYPE
SEVERE: The device's Emergency Power Off (EPO) circuit is tripped. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.407
xATSEpoReset
NOTIFICATION-TYPE
INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been reset to the armed position. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.408
xATSEpoTestMode
NOTIFICATION-TYPE
WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.409
xATSEpoArmed
NOTIFICATION-TYPE
INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.410
xATSTestInitiated
NOTIFICATION-TYPE
INFORMATIONAL: A scheduled test has been initiated. The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of test initiated (1=scheduled, 2=manual).
1.3.6.1.4.1.318.0.411
xATSTestCanceled
NOTIFICATION-TYPE
INFORMATIONAL: The scheduled test has been canceled The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of test initiated (1=scheduled, 2=manual).
1.3.6.1.4.1.318.0.412
xATSTestFailed
NOTIFICATION-TYPE
SEVERE: The initiated test has failed. This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.413
xATSTestPassed
NOTIFICATION-TYPE
INFORMATIONAL: The initiated test has passed switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.414
xATSInputContactStateAbnormal
NOTIFICATION-TYPE
SEVERE: A user input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
1.3.6.1.4.1.318.0.415
xATSInputContactStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: A user input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the input contact number. The fourth argument is the input contact name. The fifth argument is the input contact state (1=OPEN, 2=CLOSED). The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED).
1.3.6.1.4.1.318.0.416
xATSRemoteStartContactMismatch
NOTIFICATION-TYPE
SEVERE: The state of the generator's Remote Start input and the ATS's Engine Start output do not match. This indicates something wrong in the Engine Start wiring, which must be corrected. This condition will prevent the generator from being started when needed. (See also: xATSGeneratorStatusRemoteStart and xATSSwitchStatusEngineStartSignal OIDs) The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.417
xATSRemoteStartContactMismatchCleared
NOTIFICATION-TYPE
INFORMATIONAL: Mismatch in the state of the generator's Remote Start input and the ATS's Engine Start output as been resolved. This indicates something wrong in the Engine Start wiring, which must be corrected. This condition will prevent the generator from being started when needed. (See also: xATSGeneratorStatusRemoteStart and xATSSwitchStatusEngineStartSignal OIDs) The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.418
xATSDoorOpenAlarm
NOTIFICATION-TYPE
WARNING: The XATS exterior panel door is open. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.419
xATSDoorOpenAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The external door to the device is closed. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.420
xATSDCBackupAlarm
NOTIFICATION-TYPE
WARNING: The XATS's DC backup has been lost. The XATS will lose power on Source 1 failure, causing the Engine Start signal to be asserted. The XATS will then restart from Source 2. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.421
xATSDCBackupAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: DC backup alarm has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.422
xATSGeneratorLowCoolantLevelAlarm
NOTIFICATION-TYPE
SEVERE: Low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.423
xATSGeneratorLowCoolantLevelAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.424
xATSGeneratorVeryLowCoolantLevelAlarm
NOTIFICATION-TYPE
SEVERE: Very low coolant level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.425
xATSGeneratorVeryLowCoolantLevelAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected Very low coolant level has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.426
xATSGeneratorHighCoolantTempAlarm
NOTIFICATION-TYPE
SEVERE: High coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.427
xATSGeneratorHighCoolantTempAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected high coolant temperature has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.428
xATSGeneratorVeryHighCoolantTempAlarm
NOTIFICATION-TYPE
SEVERE: Very high coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.429
xATSGeneratorVeryHighCoolantTempAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.430
xATSGeneratorLowCoolantTempAlarm
NOTIFICATION-TYPE
WARNING: Low coolant temperature has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.431
xATSGeneratorLowCoolantTempAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The low coolant temperature condition has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.432
xATSGeneratorLowOilLevelAlarm
NOTIFICATION-TYPE
SEVERE: Low oil level has been detected in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.433
xATSGeneratorLowOilLevelAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low oil level alarm has been cleared in the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.434
xATSGeneratorLowBatteryVoltDuringCrankAlarm
NOTIFICATION-TYPE
SEVERE: The generator's battery voltage has been detected as low while cranking the engine. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.435
xATSGeneratorLowBatteryVoltDuringCrankAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator's low battery voltage while cranking condition has been cleared. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.436
xATSGeneratorVeryLowBatteryVoltDuringCrankAlarm
NOTIFICATION-TYPE
SEVERE: The generator's battery voltage has been detected as very low while cranking the engine. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.437
xATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator's high battery voltage while cranking condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.438
xATSGeneratorEStop
NOTIFICATION-TYPE
SEVERE: The generator's emergency stop input has been activated. After the emergency stop signal has been removed, the E-Stop condition must be cleared before the generator can be started again. E-Stop conditions can only be cleared via the generator front panel. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE).
1.3.6.1.4.1.318.0.439
xATSGeneratorEStopCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator's emergency stop condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code. The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE).
1.3.6.1.4.1.318.0.440
xATSGeneratorHighBatteryVolt
NOTIFICATION-TYPE
WARNING: The generator's battery voltage has been detected as high. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.441
xATSGeneratorHighBatteryVoltCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected high battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.442
xATSGeneratorLowBatteryVolt
NOTIFICATION-TYPE
SEVERE: The generator's battery voltage has been detected as low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.443
xATSGeneratorLowBatteryVoltCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected low battery voltage has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.444
xATSGeneratorControlSwitchNotAuto
NOTIFICATION-TYPE
SEVERE: The control switch on the generator is not in auto position. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.445
xATSGeneratorControlSwitchNotAutoCleared
NOTIFICATION-TYPE
INFORMATIONAL: The control switch on the generator is in auto position. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.446
xATSGeneratorLowOilPressure
NOTIFICATION-TYPE
SEVERE: The generator's oil pressure has been detected as low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.447
xATSGeneratorLowOilPressureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.448
xATSGeneratorVeryLowOilPressure
NOTIFICATION-TYPE
SEVERE: The generator's oil pressure has been detected as very low. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.449
xATSGeneratorVeryLowOilPressureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.450
xATSGeneratorOverload
NOTIFICATION-TYPE
SEVERE: The generator is overloaded. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.451
xATSGeneratorOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator is running within loading limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.452
xATSGeneratorLowACVEvent
NOTIFICATION-TYPE
SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.453
xATSGeneratorLowACVEventCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.454
xATSGeneratorHighACVEvent
NOTIFICATION-TYPE
SEVERE: The generator AC voltage is outside the acceptable bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.455
xATSGeneratorHighACVEventCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator AC voltage is within normal bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.456
xATSGeneratorOverspeed
NOTIFICATION-TYPE
SEVERE: The generator is running over the acceptable RPM. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.457
xATSGeneratorOverspeedCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator overspeed shutdown has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.458
xATSGeneratorEngineCold
NOTIFICATION-TYPE
SEVERE: The generator engine is cold, may not start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.459
xATSGeneratorEngineColdCleared
NOTIFICATION-TYPE
INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.460
xATSGeneratorOutputBreakerOpen
NOTIFICATION-TYPE
SEVERE: The generators output breaker has been detected as open. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.461
xATSGeneratorOutputBreakerOpenCleared
NOTIFICATION-TYPE
INFORMATIONAL: The engine is not cold to start. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.462
xATSGeneratorLowFuelLevelAlarm
NOTIFICATION-TYPE
WARNING: The tank fuel level is below the limits specified in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured fuel level in percent of full.
1.3.6.1.4.1.318.0.463
xATSGeneratorLowFuelLevelAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The tank fuel level is back above the specified limit. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.464
xATSGeneratorVeryLowFuelLevelAlarm
NOTIFICATION-TYPE
SEVERE: The tank fuel level is below the low threshold limits. The first argument is the host device serial number. The second argument is the host device name. The third argument is the measured tank fuel level in percent of full.
1.3.6.1.4.1.318.0.465
xATSGeneratorVeryLowFuelLevelAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected low tank level has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.466
xATSGeneratorLowRunTimeAlarm
NOTIFICATION-TYPE
WARNING: The estimated runtime is below the limits specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the estimated runtime in hours.
1.3.6.1.4.1.318.0.467
xATSGeneratorLowRunTimeAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.468
xATSGeneratorVeryLowRunTimeAlarm
NOTIFICATION-TYPE
SEVERE: The estimated runtime is below the limits specified in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID. The first argument is the host device serial number. The second argument is the host device name. The third argument is the estimated runtime in hours.
1.3.6.1.4.1.318.0.469
xATSGeneratorVeryLowRunTimeAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The detected low runtime has been cleared in the device. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.470
xATSGeneratorServiceDueAlarm
NOTIFICATION-TYPE
WARNING: The generator is due for scheduled service. Generation of this alarm is based on calendar days since and/or actual generator run-hours since last service. This alarm is cleared using the xATSGeneratorServiceResetRecord OID. (See also: xATSGeneratorServiceCalendarIntervalThreshold and xATSGeneratorServiceRunHoursThreshold OIDs) The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.471
xATSGeneratorServiceDueAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator's service registers have been reset. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.472
xATSGeneratorShutdown
NOTIFICATION-TYPE
SEVERE: The generator is shutdown. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.473
xATSGeneratorShutdownCleared
NOTIFICATION-TYPE
INFORMATIONAL: The generator shutdown alarm is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.474
xATSGeneratorBatteryCharger
NOTIFICATION-TYPE
SEVERE: The generator battery charger is nonfunctional. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.475
xATSGeneratorBatteryChargerCleared
NOTIFICATION-TYPE
INFORMATIONAL: Fault in the generator battery charger is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.476
xATSGeneratorGenericEvent
NOTIFICATION-TYPE
WARNING: Any generic generator event. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.477
xATSGeneratorGenericEventCleared
NOTIFICATION-TYPE
INFORMATIONAL: Generated generic generator event is cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.478
xPDUInternalCommErrorCleared
NOTIFICATION-TYPE
INFORMATIONAL: Internal communication has been restored. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.479
xPDUSystemStateAlarm
NOTIFICATION-TYPE
SEVERE: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead to system unavailability. it may signify a temporary condition, when the breakers are placed in an atypical manner as the user transitions to (UPS OPERATION or MAINTENANCE BYPASS) The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass.
1.3.6.1.4.1.318.0.480
xPDUSystemStateAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration that is a non-alarm state. The first argument is the host device serial number. The second argument is the host device name. The third argument is the type of state change (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE). note: The NO_PANEL_FEED alarm is applicable only for PDUs with system bypass.
1.3.6.1.4.1.318.0.481
xPDUEpoTestMode
NOTIFICATION-TYPE
WARNING: The device's Emergency Power Off (EPO) circuit has been switched back to the test position. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.482
xPDUEpoArmed
NOTIFICATION-TYPE
INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been switched back to the armed position. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.483
xPDUFuseBlownAlarm
NOTIFICATION-TYPE
SEVERE: One or more fuses in this PDU have been detected as open. These fuses are in the feed to the UPS associated with this PDU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.484
xPDUFuseBlownAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A previous check fuse alarm in this PDU has cleared. These fuses are in the feed to the UPS associated with this PDU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.485
xPDUBreakerPositionAlarm
NOTIFICATION-TYPE
SEVERE: A PDU breaker is in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). note: The OUTPUT breaker position alarm is applicable only for PDUs with no system bypass. The fourth argument is the breaker position (1=OPEN, 2=CLOSED).
1.3.6.1.4.1.318.0.486
xPDUBreakerPositionAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE, 4=OUTPUT). note: The OUTPUT breaker position alarm cleared is applicable only for PDUs with no system bypass.
1.3.6.1.4.1.318.0.487
xPDUBreakerChangeEvent
NOTIFICATION-TYPE
INFORMATIONAL: A system breaker or switch within the device has changed state. They are generated when any of the Q1, Q2 or Q3 breakers have changed states. The first argument is the host device serial number. The second argument is the host device name. The third argument is the breaker that has changed (1=UPS FEED (Q1), 2=UPS OUTPUT(Q2), 3=MAINTENANCE BYPASS (Q3). The fourth argument is the state of the breaker that has changed (1=OPEN, 2=CLOSED). The fifth argument is a 8-bit field representing the state of all breakers in the system, when any of one of the Q1, Q2 or Q3 breakers have changed state. The bit map is represented in the following manner (b7, b6 ... b0) b0 - UPS FEED (Q1) b1 - MAINTENANCE BYPASS (Q3) b2 - UPS OUTPUT (Q2) b3 - MAIN INPUT b4 - BYPASS INPUT b5 - CROSS-TIE OUTPUT Example: value of 60 (0x3C) indicates that the CROSS_TIE, BYPASS and MAIN INPUT, and Q2 breakers are CLOSED and Q3, Q1 breakers are OPEN.
1.3.6.1.4.1.318.0.488
xPDUDataCommMismatchError
NOTIFICATION-TYPE
SEVERE: A data incompatibility exists within the device. This is typically the result of mismatches between firmware revisions of the transfer switch controller and the Network Management interface. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.489
xPDUDataCommMismatchErrorCleared
NOTIFICATION-TYPE
INFORMATIONAL: The internal data incompatibility has been resolved. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.490
xPDUSystemInMaintenanceBypassMode
NOTIFICATION-TYPE
WARNING: The PDU state has changed to maintenance bypass mode. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.491
xPDUSystemInUPSOperationalMode
NOTIFICATION-TYPE
INFORMATIONAL: The PDU state has changed to UPS operational mode. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.492
xATSGeneratorFuelTankRuptureAlarm
NOTIFICATION-TYPE
WARNING: Detected a rupture in the inner wall of the generator fuel tank. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.493
xATSGeneratorFuelTankRuptureAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The rupture in the inner wall of the generator is not detected. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.494
xATSGeneratorGroundFaultAlarm
NOTIFICATION-TYPE
SEVERE: Generator ground fault alarm. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.495
xATSGeneratorGroundFaultAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Generator ground fault alarm cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the OEM's fault/event code.
1.3.6.1.4.1.318.0.496
xATSOutputLoadPoweredByGeneratorAlarm
NOTIFICATION-TYPE
WARNING: The system load on the output of the ATS is being powered by source 2 (generator). The first argument is the host device serial number. The second argument is the host device name. The third argument indicates if the load is powered by the generator, when 'load testing' the generator (1 = LIVE, 2 = TEST).
1.3.6.1.4.1.318.0.497
xATSOutputLoadPoweredByGeneratorAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The system load on the output of the ATS is no longer being powered by source 2 (generator). The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.498
xAPCControllerFirmwareUpdateTransferStart
NOTIFICATION-TYPE
INFORMATIONAL: Start controller firmware transfer in the device. The first argument is the host device serial number. The second argument is the host model name that initiated the transfer. The third argument is the name of the file that is transferred. The fourth argument is the updated revision of the file, if available The fifth argument is the reason for the update, if available (1=User request, 2=Automatic upgrade by NMC, 3=Unknown).
1.3.6.1.4.1.318.0.499
xAPCControllerFirmwareUpdateTransferComplete
NOTIFICATION-TYPE
INFORMATIONAL: Transfer of controller firmware was completed in the device. The first argument is the host device serial number. The second argument is the host device model name that completed the transfer. The third argument is the name of the file that was transferred. The fourth argument is the revision of the file that was transferred, if available.
1.3.6.1.4.1.318.0.500
xAPCControllerFirmwareUpdateTransferFailed
NOTIFICATION-TYPE
SEVERE: Transfer of controller firmware failed. The first argument is the host device serial number. The second argument is the host device model name that failed to transfer. The third argument is the name of the file that failed the transfer, if available. The fourth argument is the reason for failure.
1.3.6.1.4.1.318.0.501
upsPfcInputRelayFailure
NOTIFICATION-TYPE
WARNING: The PFC (Power Factor Correction) input relay failure exists.
1.3.6.1.4.1.318.0.502
upsPfcInputRelayFailureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The PFC (Power Factor Correction) input relay failure cleared.
1.3.6.1.4.1.318.0.503
upsInverterOverTemperature
NOTIFICATION-TYPE
WARNING: The inverter over temperature condition exists.
1.3.6.1.4.1.318.0.504
upsInverterOverTemperatureCleared
NOTIFICATION-TYPE
INFORMATIONAL: The inverter over temperature condition cleared.
1.3.6.1.4.1.318.0.505
upsBatteryOverVoltage
NOTIFICATION-TYPE
WARNING: The battery over voltage condition exists.
1.3.6.1.4.1.318.0.506
upsBatteryOverVoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: The battery over voltage condition cleared.
1.3.6.1.4.1.318.0.507
upsEepromFault
NOTIFICATION-TYPE
WARNING: The EEPROM fault exists.
1.3.6.1.4.1.318.0.508
upsEepromFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The EEPROM fault cleared.
1.3.6.1.4.1.318.0.509
aruFanRuntimeAlarm
NOTIFICATION-TYPE
WARNING: The total running hours for a fan has exceeded the run hour threshold. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
1.3.6.1.4.1.318.0.510
aruFanRuntimeAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The total running hours for a fan is no longer above the fan runhour threshold. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
1.3.6.1.4.1.318.0.511
aruFanPoorPerformanceAlarm
NOTIFICATION-TYPE
WARNING: Poor fan performance has been detected in the ARU, indicating that the fan may be close to failing. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
1.3.6.1.4.1.318.0.512
aruFanPoorPerformanceAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Fan performance is no longer degraded. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name. The fifth argument indicates which fan in the ARU.
1.3.6.1.4.1.318.0.513
aruRedundantPowerLostAlarm
NOTIFICATION-TYPE
WARNING: One of the redundant line cords on the ARU is no longer receiving AC power. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.514
aruRedundantPowerLostAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: Line-cord redundancy has been restored to the ARU. The first argument is the host device serial number. The second argument is the host device name. The third argument is the ARU number. The fourth argument is the ARU name.
1.3.6.1.4.1.318.0.515
apcDeviceConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: A device configuration change has been made on the device. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.516
apcEnvSensorConnected
NOTIFICATION-TYPE
INFORMATIONAL: A sensor has been connected to the host device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.517
apcEnvSensorDisconnected
NOTIFICATION-TYPE
SEVERE: A sensor has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.518
apcEnvMaxTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: Max temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.519
apcEnvMaxTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Max temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.520
apcEnvHighTempThresholdViolation
NOTIFICATION-TYPE
WARNING: High temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.521
apcEnvHighTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.522
apcEnvLowTempThresholdViolation
NOTIFICATION-TYPE
WARNING: Low temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.523
apcEnvLowTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.524
apcEnvMinTempThresholdViolation
NOTIFICATION-TYPE
SEVERE: Min temperature threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.525
apcEnvMinTempThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Min temperature threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The sixth argument is the sensor number. The seventh argument is the sensor name.
1.3.6.1.4.1.318.0.526
apcEnvSTIncTempRateViolation
NOTIFICATION-TYPE
SEVERE: Short-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.527
apcEnvSTIncTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Short-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.528
apcEnvSTDecTempRateViolation
NOTIFICATION-TYPE
SEVERE: Short-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.529
apcEnvSTDecTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Short-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.530
apcEnvLTIncTempRateViolation
NOTIFICATION-TYPE
SEVERE: Long-term increasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.531
apcEnvLTIncTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Long-term increasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.532
apcEnvLTDecTempRateViolation
NOTIFICATION-TYPE
SEVERE: Long-term decreasing temperature rate violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.533
apcEnvLTDecTempRateViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Long-term decreasing temperature rate cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.534
apcEnvMaxHumidityThresholdViolation
NOTIFICATION-TYPE
SEVERE: Max humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.535
apcEnvMaxHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Max humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.536
apcEnvHighHumidityThresholdViolation
NOTIFICATION-TYPE
WARNING: High humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.537
apcEnvHighHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.538
apcEnvLowHumidityThresholdViolation
NOTIFICATION-TYPE
WARNING: Low humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.539
apcEnvLowHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.540
apcEnvMinHumidityThresholdViolation
NOTIFICATION-TYPE
SEVERE: Min humidity threshold violated on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.541
apcEnvMinHumidityThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Min humidity threshold violation cleared on the sensor. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the sensor number. The fifth argument is the sensor name.
1.3.6.1.4.1.318.0.542
apcBeaconConnected
NOTIFICATION-TYPE
INFORMATIONAL: A beacon has been connected to the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.543
apcBeaconDisconnected
NOTIFICATION-TYPE
SEVERE: A beacon has been disconnected from the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.544
apcBeaconOn
NOTIFICATION-TYPE
INFORMATIONAL: A beacon has gone on (activated). The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.545
apcBeaconOff
NOTIFICATION-TYPE
INFORMATIONAL: A beacon has gone off (deactivated). The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.546
apcOutletStateAbnormal
NOTIFICATION-TYPE
WARNING: An outlet on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the outlet number. The fifth argument is the outlet name. The sixth argument is the current outlet state (1=ON, 2=OFF). The seventh argument is the configured normal outlet state (1=ON, 2=OFF).
1.3.6.1.4.1.318.0.547
apcOutletStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: An outlet on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the outlet number. The fifth argument is the outlet name. The sixth argument is the current outlet state (1=ON, 2=OFF). The seventh argument is the configured normal outlet state (1=ON, 2=OFF).
1.3.6.1.4.1.318.0.548
apcOutputRelayStateAbnormal
NOTIFICATION-TYPE
WARNING: An output relay on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the output relay number. The fifth argument is the output relay name. The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.549
apcOutputRelayStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: An output relay on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the output relay number. The fifth argument is the output relay name. The sixth argument is the current output relay state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal output relay state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.550
apcHardwareStateAbnormal
NOTIFICATION-TYPE
SEVERE: The device's hardware is improperly configured and operating outside normal bounds for the hardware. This can be caused by improper devices being connected to device ports or Alink Current limit detection. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is a hardware specific state code.
1.3.6.1.4.1.318.0.551
apcHardwareStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: The device's hardware is in its normal operational state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.552
apcCriticalDiscreteInputContactStateAbnormal
NOTIFICATION-TYPE
SEVERE: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.553
apcCriticalDiscreteInputContactStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.554
apcWarningDiscreteInputContactStateAbnormal
NOTIFICATION-TYPE
WARNING: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.555
apcWarningDiscreteInputContactStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.556
apcInformationalDiscreteInputContactStateAbnormal
NOTIFICATION-TYPE
INFORMATIONAL: A discrete input contact on the device has changed to its abnormal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.557
apcInformationalDiscreteInputContactStateNormal
NOTIFICATION-TYPE
INFORMATIONAL: A discrete input contact on the device has changed to its normal state. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input contact number. The fifth argument is the input contact name. The sixth argument is the input contact state (1=CLOSED, 2=OPEN). The seventh argument is the configured normal input contact state (1=CLOSED, 2=OPEN).
1.3.6.1.4.1.318.0.558
apcAnalogInputMaxThresholdViolation
NOTIFICATION-TYPE
SEVERE: Maximum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.559
apcAnalogInputMaxThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Maximum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.560
apcAnalogInputHighThresholdViolation
NOTIFICATION-TYPE
WARNING: High threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.561
apcAnalogInputHighThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: High threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.562
apcAnalogInputLowThresholdViolation
NOTIFICATION-TYPE
WARNING: Low threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.563
apcAnalogInputLowThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Low threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.564
apcAnalogInputMinThresholdViolation
NOTIFICATION-TYPE
SEVERE: Minimum threshold violated on an analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.565
apcAnalogInputMinThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: Minimum threshold violation cleared on the analog input. The first argument is the host device serial number. The second argument is the host device name. The third argument is a secondary device id number. The fourth argument is the input number. The fifth argument is the input name.
1.3.6.1.4.1.318.0.566
apcDeviceClearLostComms
NOTIFICATION-TYPE
INFORMATIONAL: Lost communications reset command has been issued. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.567
apcDeviceConnected
NOTIFICATION-TYPE
INFORMATIONAL: A device has been connected to the host. The first argument is the host serial number. The second argument is the host name. The third argument is the device number. The fourth argument is the device name.
1.3.6.1.4.1.318.0.568
apcDeviceDisconnected
NOTIFICATION-TYPE
SEVERE: A device has been disconnected from the host. The first argument is the host serial number. The second argument is the host name. The third argument is the device number. The fourth argument is the device name.
1.3.6.1.4.1.318.0.569
apcUnregisteredUserAccessDenied
NOTIFICATION-TYPE
INFORMATIONAL: An unregistered user has tried to access the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argumant is the door identifier. The fifth argument is the unregistered user's RFID.
1.3.6.1.4.1.318.0.570
apcRegisteredUserAccessDenied
NOTIFICATION-TYPE
INFORMATIONAL: A registered user has been denied access to the device. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argumant is the door identifier. The fifth argument is the user name.
1.3.6.1.4.1.318.0.571
apcRegisteredUserConfigChange
NOTIFICATION-TYPE
INFORMATIONAL: Registered user configuration change. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name.
1.3.6.1.4.1.318.0.572
apcDoorUnlocked
NOTIFICATION-TYPE
INFORMATIONAL: A door has been unlocked. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier. The fifth argument is the door access user. The sixth argument is the door access type.
1.3.6.1.4.1.318.0.573
apcDoorLocked
NOTIFICATION-TYPE
INFORMATIONAL: A door has been locked. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier. The fifth argument is the door access user. The sixth argument is the door access type.
1.3.6.1.4.1.318.0.574
apcHandleOpened
NOTIFICATION-TYPE
INFORMATIONAL: A door handle has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.575
apcHandleClosed
NOTIFICATION-TYPE
INFORMATIONAL: A door handle has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.576
apcDoorOpened
NOTIFICATION-TYPE
INFORMATIONAL: A door has been opened. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.577
apcDoorClosed
NOTIFICATION-TYPE
INFORMATIONAL: A door has been closed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.578
apcKeyOverrideUnlocked
NOTIFICATION-TYPE
SEVERE: Key override unlock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.580
apcKeyOverrideLocked
NOTIFICATION-TYPE
INFORMATIONAL: Key override lock has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.581
apcForcedEntry
NOTIFICATION-TYPE
SEVERE: A forced entry condition has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.582
apcForcedEntryCleared
NOTIFICATION-TYPE
INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.583
apcRelockTimeout
NOTIFICATION-TYPE
SEVERE: A relock timout has occurred. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.584
apcRelockTimeoutCleared
NOTIFICATION-TYPE
INFORMATIONAL: A relock timout has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.585
apcDoorSenseDisconnected
NOTIFICATION-TYPE
SEVERE: A door sensor was disconnected. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.586
apcDoorSenseConnected
NOTIFICATION-TYPE
INFORMATIONAL: A forced entry condition has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.587
apcDoorLostComms
NOTIFICATION-TYPE
SEVERE: Communications have been lost with the door. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.588
apcDoorEstablishedComms
NOTIFICATION-TYPE
INFORMATIONAL: Communications have been established with the door. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.589
apcRegisteredUserAccessChange
NOTIFICATION-TYPE
INFORMATIONAL: Registered user access changed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name.
1.3.6.1.4.1.318.0.590
apcUnregisteredUserStatusChange
NOTIFICATION-TYPE
INFORMATIONAL: Unregistered user status changed. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the user name.
1.3.6.1.4.1.318.0.591
apcDeviceClearUserConfigs
NOTIFICATION-TYPE
INFORMATIONAL: User configurations reset command has been issued. The first argument is the device serial number. The second argument is the device name. The third argument is a secondary device id number.
1.3.6.1.4.1.318.0.592
upsBatteryTempSensorFault
NOTIFICATION-TYPE
WARNING: The battery temperature sensor fault exists.
1.3.6.1.4.1.318.0.600
upsBatteryTempSensorFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The battery temperature sensor fault cleared.
1.3.6.1.4.1.318.0.601
upsBatterySoftBusStartFault
NOTIFICATION-TYPE
WARNING: A battery bus soft start fault exists.
1.3.6.1.4.1.318.0.602
upsBatterySoftBusStartFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: A battery bus soft start fault exists cleared.
1.3.6.1.4.1.318.0.603
apcOutputShortCircuit
NOTIFICATION-TYPE
WARNING: An output short circuit condition exists.
1.3.6.1.4.1.318.0.604
apcOutputShortCircuitCleared
NOTIFICATION-TYPE
INFORMATIONAL: An output short circuit condition cleared.
1.3.6.1.4.1.318.0.605
apcOutputRelayFault
NOTIFICATION-TYPE
WARNING: An output relay (or its driver) fault exists.
1.3.6.1.4.1.318.0.606
apcOutputRelayFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: An output relay (or its driver) fault cleared.
1.3.6.1.4.1.318.0.607
upsPfcFault
NOTIFICATION-TYPE
WARNING: A PFC fault exists.
1.3.6.1.4.1.318.0.608
upsPfcFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The PFC fault cleared.
1.3.6.1.4.1.318.0.609
apcDcBusOverVoltage
NOTIFICATION-TYPE
WARNING: The DC bus voltage is too high.
1.3.6.1.4.1.318.0.610
apcDcBusOverVoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: The DC bus voltage is too high cleared.
1.3.6.1.4.1.318.0.611
upsInverterFault
NOTIFICATION-TYPE
WARNING: The inverter fault exists.
1.3.6.1.4.1.318.0.612
upsInverterFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The inverter fault cleared.
1.3.6.1.4.1.318.0.613
apcAdConverterFault
NOTIFICATION-TYPE
WARNING: The A/D converter fault exists.
1.3.6.1.4.1.318.0.614
apcAdConverterFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The A/D converter fault cleared.
1.3.6.1.4.1.318.0.615
apcLogicPowerSupplyFault
NOTIFICATION-TYPE
WARNING: A logic power supply fault exists.
1.3.6.1.4.1.318.0.616
apcLogicPowerSupplyFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: A logic power supply fault cleared.
1.3.6.1.4.1.318.0.617
apcTransformerDCImbalanceFault
NOTIFICATION-TYPE
WARNING: The DC component of the transformer's current is too high.
1.3.6.1.4.1.318.0.618
apcTransformerDCImbalanceFaultCleared
NOTIFICATION-TYPE
WARNING: The DC component of the transformer's current is normal.
1.3.6.1.4.1.318.0.619
upsBackfeedRelayFault
NOTIFICATION-TYPE
WARNING: The backfeed relay (or its driver) has a fault.
1.3.6.1.4.1.318.0.620
upsBackfeedRelayFaultCleared
NOTIFICATION-TYPE
WARNING: The backfeed relay (or its driver) has a fault cleared.
1.3.6.1.4.1.318.0.621
upsBypassRelayFault
NOTIFICATION-TYPE
WARNING: A bypass relay (or its driver) has a fault.
1.3.6.1.4.1.318.0.622
upsBypassRelayFaultCleared
NOTIFICATION-TYPE
WARNING: A bypass relay (or its driver) has a fault cleared.
1.3.6.1.4.1.318.0.623
xPDUBranchCurrentMinAlarm
NOTIFICATION-TYPE
SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.626
xPDUBranchCurrentMinAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.627
xPDUBranchCurrentMaxAlarm
NOTIFICATION-TYPE
SEVERE: The current in a branch circuit is outside the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps. The fifth argument is the threshold, in tenths of Amps, above which the alarm was generated.
1.3.6.1.4.1.318.0.628
xPDUBranchCurrentMaxAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a branch circuit is back within the limits specified for that branch circuit. The first argument is the host device serial number. The second argument is the host device name. The third argument is the panel position of the branch circuit (1-based index). The fourth argument is the measured current in tenths of Amps.
1.3.6.1.4.1.318.0.629
rPDUOutletLowLoad
NOTIFICATION-TYPE
WARNING: A Rack PDU has violated the outlet low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
1.3.6.1.4.1.318.0.630
rPDUOutletLowLoadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The outlet low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
1.3.6.1.4.1.318.0.631
rPDUOutletNearOverload
NOTIFICATION-TYPE
WARNING: A Rack PDU is near an outlet overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
1.3.6.1.4.1.318.0.632
rPDUOutletNearOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The outlet near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
1.3.6.1.4.1.318.0.633
rPDUOutletOverload
NOTIFICATION-TYPE
SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
1.3.6.1.4.1.318.0.634
rPDUOutletOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The outlet overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number.
1.3.6.1.4.1.318.0.635
apcTestTrap
NOTIFICATION-TYPE
INFORMATIONAL: Trap used to test SNMP trap functionality. The first argument is a place holder for test variables.
1.3.6.1.4.1.318.0.636
baseFanFailureCleared
NOTIFICATION-TYPE
INFORMATIONAL: Base module fan has been repaired
1.3.6.1.4.1.318.0.637
atsLowLoad
NOTIFICATION-TYPE
WARNING: ATS has violated the bank or phase low load threshold. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
1.3.6.1.4.1.318.0.638
atsLowLoadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The bank or phase low load condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
1.3.6.1.4.1.318.0.639
atsNearOverload
NOTIFICATION-TYPE
WARNING: ATS has violated the bank or phase near overload threshold. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
1.3.6.1.4.1.318.0.640
atsNearOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The bank or phase near overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number The fourth argument is the bank number. -1 is returned if bank does not exist.
1.3.6.1.4.1.318.0.641
atsOverload
NOTIFICATION-TYPE
SEVERE: ATS is in an overload condition. The first argument is the serial number. The second argument is the product name. The third argument is the phase number. The fourth argument is the bank number. -1 is returned if bank does not exist.
1.3.6.1.4.1.318.0.642
atsOverloadCleared
NOTIFICATION-TYPE
INFORMATIONAL: The bank or phase overload condition on an ATS has been cleared. The first argument is the serial number. The second argument is the product name. The third argument is the phase number. The fourth argument is the bank number. -1 is returned if bank does not exist.
1.3.6.1.4.1.318.0.643
atsRMSOverVoltage
NOTIFICATION-TYPE
SEVERE: Overvoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.644
atsRMSOverVoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: Overvoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.645
atsRMSUnderVoltage
NOTIFICATION-TYPE
SEVERE: Undervoltage condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.646
atsRMSUnderVoltageCleared
NOTIFICATION-TYPE
INFORMATIONAL: Undervoltage condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.647
atsRMSOverFrequency
NOTIFICATION-TYPE
SEVERE: OverFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.648
atsRMSOverFrequencyCleared
NOTIFICATION-TYPE
INFORMATIONAL: OverFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.649
atsRMSUnderFrequency
NOTIFICATION-TYPE
SEVERE: UnderFrequency condition violated. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.650
atsRMSUnderFrequencyCleared
NOTIFICATION-TYPE
INFORMATIONAL: UnderFrequency condition cleared. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.651
isxModularDistributionCommLost
NOTIFICATION-TYPE
SEVERE: Communication with a metering segment of the modular distribution system has been lost. The first argument is the host device serial number. The second argument is the host device name. The third argument is the segment number. The fourth argument describes the modules served by this metering segment.
1.3.6.1.4.1.318.0.652
isxModularDistributionCommEstablished
NOTIFICATION-TYPE
INFORMATIONAL: Communication with a metering segment of the modular distribution system has been restored. The first argument is the host device serial number. The second argument is the host device name. The third argument is the segment number. The fourth argument describes the modules served by this metering segment.
1.3.6.1.4.1.318.0.653
isxModularDistributionModuleInserted
NOTIFICATION-TYPE
INFORMATIONAL: A distribution module has been inserted into the system. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module location number.
1.3.6.1.4.1.318.0.654
isxModularDistributionModuleRemoved
NOTIFICATION-TYPE
INFORMATIONAL: A distribution module has been removed from the system. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module location number.
1.3.6.1.4.1.318.0.655
isxModularBreakerOpenAlarm
NOTIFICATION-TYPE
SEVERE: A distribution module breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the module breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.656
isxModularBreakerOpenAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: An alarm caused by a distribution breaker being open has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker(s) (1=L1, 2=L2, 3=L3, 4=L12, 5=L23, 6=L123). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.657
isxModularMinCurrentThresholdViolation
NOTIFICATION-TYPE
SEVERE: The current in a distribution module is below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.658
isxModularMinCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution module is no longer below the minimum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.659
isxModularLowCurrentThresholdViolation
NOTIFICATION-TYPE
WARNING: The current in a distribution module is below the low/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.660
isxModularLowCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution module is no longer below the low/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.661
isxModularHighCurrentThresholdViolation
NOTIFICATION-TYPE
WARNING: The current in a distribution module is above the high/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.662
isxModularHighCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution module is no longer above the high/warning limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.663
isxModularMaxCurrentThresholdViolation
NOTIFICATION-TYPE
SEVERE: The current in a distribution module is above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.664
isxModularMaxCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution module is no longer above the maximum/critical limit specified for the circuit/cable. The first argument is the host device serial number. The second argument is the host device name. The third argument is the module number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the circuit/cable fed by this breaker.
1.3.6.1.4.1.318.0.665
isxModularSubfeedBreakerOpenAlarm
NOTIFICATION-TYPE
SEVERE: A distribution subfeed breaker is open and in an alarm condition. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.666
isxModularSubfeedBreakerOpenAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: An alarm caused by a distribution subfeed breaker being open has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.667
isxModularSubfeedMinCurrentThresholdViolation
NOTIFICATION-TYPE
SEVERE: The current in a distribution subfeed is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.668
isxModularSubfeedMinCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution subfeed is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.669
isxModularSubfeedLowCurrentThresholdViolation
NOTIFICATION-TYPE
WARNING: The current in a distribution subfeed is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.670
isxModularSubfeedLowCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution subfeed is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.671
isxModularSubfeedHighCurrentThresholdViolation
NOTIFICATION-TYPE
WARNING: The current in a distribution subfeed is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.672
isxModularSubfeedHighCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution subfeed is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.673
isxModularSubfeedMaxCurrentThresholdViolation
NOTIFICATION-TYPE
SEVERE: The current in a distribution subfeed is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the threshold, in tenths of Amps, from which the alarm was generated. The sixth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.674
isxModularSubfeedMaxCurrentThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The current in a distribution subfeed is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the subfeed number. The fourth argument is the breaker/phase index (1=L1, 2=L2, 3=L3). The fifth argument is the load name associated with the subfeed.
1.3.6.1.4.1.318.0.675
isxModularTotalOutputCurrentMinThresholdViolation
NOTIFICATION-TYPE
SEVERE: The total output current of the distribution is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.676
isxModularTotalOutputCurrentMinThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The total output current of the distribution is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.677
isxModularTotalOutputCurrentLowThresholdViolation
NOTIFICATION-TYPE
WARNING: The total output current of the distribution is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.678
isxModularTotalOutputCurrentLowThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The total output current of the distribution is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.679
isxModularTotalOutputCurrentHighThresholdViolation
NOTIFICATION-TYPE
WARNING: The total output current of the distribution is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.680
isxModularTotalOutputCurrentHighThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The total output current of the distribution is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.681
isxModularTotalOutputCurrentMaxThresholdViolation
NOTIFICATION-TYPE
SEVERE: The total output current of the distribution is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Amps, from which the alarm was generated.
1.3.6.1.4.1.318.0.682
isxModularTotalOutputCurrentMaxThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The total output current of the distribution is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.683
isxModularOutputVoltageMinThresholdViolation
NOTIFICATION-TYPE
SEVERE: The distribution output voltage is below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.684
isxModularOutputVoltageMinThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The distribution output voltage is no longer below the minimum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.685
isxModularOutputVoltageLowThresholdViolation
NOTIFICATION-TYPE
WARNING: The distribution output voltage is below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.686
isxModularOutputVoltageLowThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The distribution output voltage is no longer below the low/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.687
isxModularOutputVoltageHighThresholdViolation
NOTIFICATION-TYPE
WARNING: The distribution output voltage is above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.688
isxModularOutputVoltageHighThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The distribution output voltage is no longer above the high/warning limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.689
isxModularOutputVoltageMaxThresholdViolation
NOTIFICATION-TYPE
SEVERE: The distribution output voltage is above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3). The fourth argument is the threshold, in tenths of Volts, from which the alarm was generated.
1.3.6.1.4.1.318.0.690
isxModularOutputVoltageMaxThresholdViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The distribution output voltage is no longer above the maximum/critical limit specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the phase index (1=L1, 2=L2, 3=L3).
1.3.6.1.4.1.318.0.691
apcDoorClosedImproperly
NOTIFICATION-TYPE
SEVERE: A door has been closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.692
apcDoorClosedImproperlyCleared
NOTIFICATION-TYPE
INFORMATIONAL: A door is no longer closed improperly. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.693
apcUserScheduleViolation
NOTIFICATION-TYPE
SEVERE: A user has had a door opened past the scheduled access period. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.694
apcUserScheduleViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: User schedule violation has been cleared. The first argument is the host device serial number. The second argument is the host device name. The third argument is the host device location. The fourth argument is the door identifier, (1=front, 2=rear).
1.3.6.1.4.1.318.0.695
isxModularOutputFrequencyThresholdViolation
NOTIFICATION-TYPE
SEVERE: The distribution output frequency is outside of the operating range specified. The first argument is the host device serial number. The second argument is the host device name. The third argument is the threshold, in tenths of Hertz, from which the alarm was generated.
1.3.6.1.4.1.318.0.696
isxModularOutputFrequencyViolationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The distribution output frequency is no longer out of range. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.697
atsSourceStatusFail
NOTIFICATION-TYPE
SEVERE: ATS Source failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.698
atsSourceStatusOk
NOTIFICATION-TYPE
INFORMATIONAL: ATS Source OK. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the source: 0=A, 1=B.
1.3.6.1.4.1.318.0.699
atsHardwareStatusFail
NOTIFICATION-TYPE
SEVERE: ATS display board hardware failed. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the failed hardware: 0= Phase LEDs/Push-button hardware failure 1= Seven-segment display hardware failure.
1.3.6.1.4.1.318.0.700
atsHardwareStatusOk
NOTIFICATION-TYPE
INFORMATIONAL: ATS display board hardware ok. The first argument is the serial number. The second argument is the product name. The third argument is an integer representing the hardware: 0= Phase LEDs/Push-button hardware failure 1= Seven-segment display hardware failure.
1.3.6.1.4.1.318.0.701
atsControllerRestart
NOTIFICATION-TYPE
INFORMATIONAL: ATS Controller restarted.
1.3.6.1.4.1.318.0.702
inputWarningError
NOTIFICATION-TYPE
WARNING: Input warning error has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.703
inputOK
NOTIFICATION-TYPE
INFORMATIONAL: Input warning error has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.704
bypassWarningError
NOTIFICATION-TYPE
WARNING: Bypass warning error has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.705
bypassOK
NOTIFICATION-TYPE
INFORMATIONAL: Bypass warning error has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.706
communicationWarningError
NOTIFICATION-TYPE
WARNING: Communication warning error has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.707
communicationOK
NOTIFICATION-TYPE
INFORMATIONAL: Communication warning error has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.708
powerModuleSevereError
NOTIFICATION-TYPE
SEVERE: Power module severe error has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.709
powerModuleOK
NOTIFICATION-TYPE
INFORMATIONAL: Power module severe error has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.710
outputVoltageWaveformError
NOTIFICATION-TYPE
SEVERE: Output voltage waveform error has been detected.
1.3.6.1.4.1.318.0.711
outputVoltageWaveformOK
NOTIFICATION-TYPE
INFORMATIONAL: Output voltage waveform is OK.
1.3.6.1.4.1.318.0.712
bypassStaticSwitchOverload
NOTIFICATION-TYPE
SEVERE: Overload on bypass static switch has been detected.
1.3.6.1.4.1.318.0.713
noOverloadOnBypassStaticSwitch
NOTIFICATION-TYPE
INFORMATIONAL: Overload on static bypass switch no longer present.
1.3.6.1.4.1.318.0.714
batteryVoltageCollapse
NOTIFICATION-TYPE
SEVERE: Battery voltage collapse has been detected.
1.3.6.1.4.1.318.0.715
batteryVoltageOK
NOTIFICATION-TYPE
INFORMATIONAL: Battery voltage OK.
1.3.6.1.4.1.318.0.716
overloadOnInstallation
NOTIFICATION-TYPE
SEVERE: Overload on installation has been detected.
1.3.6.1.4.1.318.0.717
noOverloadOnInstallation
NOTIFICATION-TYPE
INFORMATIONAL: Overload on installation no longer present.
1.3.6.1.4.1.318.0.718
bypassStaticSwitchError
NOTIFICATION-TYPE
SEVERE: Bypass static switch error, module has critical error.
1.3.6.1.4.1.318.0.719
bypassStaticSwitchOK
NOTIFICATION-TYPE
INFORMATIONAL: Bypass static switch OK.
1.3.6.1.4.1.318.0.720
forcedBypassSwitchActivated
NOTIFICATION-TYPE
SEVERE: Forced bypass switch has been activated.
1.3.6.1.4.1.318.0.721
forcedBypassSwitchReleased
NOTIFICATION-TYPE
INFORMATIONAL: Forced bypass switch has been released.
1.3.6.1.4.1.318.0.722
epoActivated
NOTIFICATION-TYPE
SEVERE: Emergency Power Off (EPO) switch has been activated.
1.3.6.1.4.1.318.0.723
xATSS1BadPhaseRotation
NOTIFICATION-TYPE
SEVERE: The device's source 1 phase rotation is bad. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.724
xATSS1BadPhaseRotationCleared
NOTIFICATION-TYPE
INFORMATIONAL: The device's source 1 phase rotation is back to normal. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.725
xATSS1BadPhaseBalance
NOTIFICATION-TYPE
SEVERE: The device's source 1 phase balance is out of bounds. The first argument is the host device serial number. The second argument is the host device name. The third argument is the minimum phase balance as a percentage.
1.3.6.1.4.1.318.0.726
xATSS1BadPhaseBalanceCleared
NOTIFICATION-TYPE
INFORMATIONAL: The device's source 1 phase balance is back to normal. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.727
isxModularTransformerOverheating
NOTIFICATION-TYPE
SEVERE: The distribution transformer temperature is too hot. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.728
isxModularTransformerOverheatingCleared
NOTIFICATION-TYPE
INFORMATIONAL: The distribution transformer temperature has returned to normal. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.729
apcInternalCommunicationFault
NOTIFICATION-TYPE
SEVERE: An internal UPS communication fault exists.
1.3.6.1.4.1.318.0.730
apcInternalCommunicationFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: An internal UPS communication fault no longer exists.
1.3.6.1.4.1.318.0.731
upsOutletGroupCommand
NOTIFICATION-TYPE
WARNING: The specified Outlet Group command has been issued.
1.3.6.1.4.1.318.0.732
onbatterycommunicationLost
NOTIFICATION-TYPE
SEVERE: Communication to the UPS when the UPS is on Battery. Steps to reestablish communication are in progress.
1.3.6.1.4.1.318.0.733
upsCriticalCondition
NOTIFICATION-TYPE
SEVERE: A UPS critical condition was detected. The first variable is the error condition text message. The second variable is the error number.
1.3.6.1.4.1.318.0.734
upsCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A UPS critical condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.735
upsWarningCondition
NOTIFICATION-TYPE
WARNING: A UPS warning condition has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.736
upsWarningConditionCleared
NOTIFICATION-TYPE
WARNING: A UPS warning condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.737
upsInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: A UPS informational condition has been detected. The first variable is the fault condition.
1.3.6.1.4.1.318.0.738
upsInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A UPS informational condition has been cleared. The first variable is the fault condition.
1.3.6.1.4.1.318.0.739
isxcInformationalAlarm
NOTIFICATION-TYPE
INFORMATIONAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.740
isxcInformationalAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.741
isxcWarningAlarm
NOTIFICATION-TYPE
WARNING: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.742
isxcWarningAlarmCleared
NOTIFICATION-TYPE
WARNING: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.743
isxcErrorAlarm
NOTIFICATION-TYPE
ERROR: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.744
isxcErrorAlarmCleared
NOTIFICATION-TYPE
ERROR: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.745
isxcCriticalAlarm
NOTIFICATION-TYPE
CRITICAL: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.746
isxcCriticalAlarmCleared
NOTIFICATION-TYPE
CRITICAL: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.747
isxcFailureAlarm
NOTIFICATION-TYPE
FAILURE: An ISXC Alarm exists. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.748
isxcFailureAlarmCleared
NOTIFICATION-TYPE
FAILURE: An ISXC Alarm has been cleared. The first argument is the unique ISXC alarm ID. The second argument is the ISXC alarm label as a UTF8 string. The third argument is the ISXC alarm code. The fourth argument is the unique ISXC device ID. The fifth argument is the ISXC device label as a UTF8 string. The sixth argument is the ISXC parent host. The seventh argument is the ISXC device type as a UTF8 string. The eighth argument is the device serial number. The ninth argument is the device model number. The tenth argument is the device host. The eleventh argument is the device location as a UTF8 string. The twelfth argument is the device contact as a UTF8 string. The thirteenth argument is the unique ISXC sensor ID. The fourteenth argument is the ISXC sensor label as a UTF8 string. The fifteenth argument is the sensor value as a UTF8 string. The sixteenth argument is the ISXC alarm start time. The seventeenth argument is the ISXC alarm resolution time. The eighteenth argument is the description as a UTF8 string.
1.3.6.1.4.1.318.0.749
rpduCriticalCondition
NOTIFICATION-TYPE
SEVERE: A RPDU critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
1.3.6.1.4.1.318.0.750
rpduCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A RPDU critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
1.3.6.1.4.1.318.0.751
rpduWarningCondition
NOTIFICATION-TYPE
WARNING: A RPDU warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
1.3.6.1.4.1.318.0.752
rpduWarningConditionCleared
NOTIFICATION-TYPE
WARNING: A RPDU warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
1.3.6.1.4.1.318.0.753
rpduInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: A RPDU informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
1.3.6.1.4.1.318.0.754
rpduInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A RPDU informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the error number. The fourth variable is the device number. The fifth variable is the instance number. The sixth variable is the trap text message.
1.3.6.1.4.1.318.0.755
isxModularCoolingFanAlarm
NOTIFICATION-TYPE
SEVERE: The device's internal cooling fans have failed. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.756
isxModularCoolingFanAlarmCleared
NOTIFICATION-TYPE
INFORMATIONAL: The device's internal cooling fans are now functioning properly. The first argument is the host device serial number. The second argument is the host device name.
1.3.6.1.4.1.318.0.757
upsFirmwareUpdateStarted
NOTIFICATION-TYPE
WARNING: Updating UPS firmware.
1.3.6.1.4.1.318.0.758
upsFirmwareUpdateFinished
NOTIFICATION-TYPE
INFORMATIONAL: Finished updating UPS firmware.
1.3.6.1.4.1.318.0.759
upsFirmwareUpdateSucceeded
NOTIFICATION-TYPE
INFORMATIONAL: UPS firmware update succeeded.
1.3.6.1.4.1.318.0.760
upsFirmwareUpdateFailed
NOTIFICATION-TYPE
WARNING: UPS firmware update failed.
1.3.6.1.4.1.318.0.761
upsHasNoValidFirmware
NOTIFICATION-TYPE
SEVERE: UPS has no valid firmware.
1.3.6.1.4.1.318.0.762
upsHasNoValidFirmwareCleared
NOTIFICATION-TYPE
INFORMATIONAL: UPS now has a valid firmware.
1.3.6.1.4.1.318.0.763
upsLocalDisplayButtonFault
NOTIFICATION-TYPE
WARNING: A local display button fault exists.
1.3.6.1.4.1.318.0.767
upsLocalDisplayButtonFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: A local display button fault no longer exists.
1.3.6.1.4.1.318.0.768
upsNeedsFactorySetupFault
NOTIFICATION-TYPE
SEVERE: UPS needs factory setup.
1.3.6.1.4.1.318.0.769
upsNeedsFactorySetupFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: UPS no longer needs factory setup.
1.3.6.1.4.1.318.0.770
upsEPOActive
NOTIFICATION-TYPE
SEVERE: Emergency Power Off (EPO) active.
1.3.6.1.4.1.318.0.771
upsEPOActiveCleared
NOTIFICATION-TYPE
INFORMATIONAL: Emergency Power Off (EPO) now inactive.
1.3.6.1.4.1.318.0.772
upsFirmwareMismatch
NOTIFICATION-TYPE
SEVERE: A firmware mismatch error exists.
1.3.6.1.4.1.318.0.773
upsFirmwareMismatchCleared
NOTIFICATION-TYPE
INFORMATIONAL: A firmware mismatch error no longer exists.
1.3.6.1.4.1.318.0.774
upsOscillatorFailed
NOTIFICATION-TYPE
SEVERE: An oscillator error exists.
1.3.6.1.4.1.318.0.775
upsOscillatorFailedCleared
NOTIFICATION-TYPE
INFORMATIONAL: An oscillator error no longer exists.
1.3.6.1.4.1.318.0.776
upsOnBatteryDueToFault
NOTIFICATION-TYPE
SEVERE: The UPS is on battery due to an error. Symmetra UPSes: Intelligence module has reported being in self-test for too long. When this happens, the UPS is not usually in self-test, but the batteries are draining slowly. If left uncorrected, the batteries will become depleted and the UPS will not be able to turn on. If UPS has at least N+1 redundancy, check power modules one by one to determine which keeps the UPS in self-test. Once identified, replace the module.
1.3.6.1.4.1.318.0.777
upsOnBatteryDueToFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: The UPS is no longer on battery due to an error.
1.3.6.1.4.1.318.0.778
pcnsCriticalEventActive
NOTIFICATION-TYPE
SEVERE: PowerChute Network Shutdown has begun a safe shutdown of the host.
1.3.6.1.4.1.318.0.779
pcnsCriticalEventResolved
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute Network Shutdown critical event resolved. Safe shutdown will continue.
1.3.6.1.4.1.318.0.780
pcnsNetworkComsLost
NOTIFICATION-TYPE
SEVERE: PowerChute cannot communicate with NMC
1.3.6.1.4.1.318.0.781
pcnsNetworkComsLostResolved
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute can communicate with NMC again.
1.3.6.1.4.1.318.0.782
pcnsNMCComsLost
NOTIFICATION-TYPE
SEVERE: NMC cannot communicate with UPS.
1.3.6.1.4.1.318.0.783
pcnsNMCComsLostResolved
NOTIFICATION-TYPE
INFORMATIONAL: NMC can communicate with UPS again.
1.3.6.1.4.1.318.0.784
pcnsTest
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute has sent a test trap.
1.3.6.1.4.1.318.0.785
pcnsUpdateAvailable
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute has detected that a newer version is available.
1.3.6.1.4.1.318.0.786
temporaryBypass
NOTIFICATION-TYPE
WARNING: UPS on temporary bypass
1.3.6.1.4.1.318.0.787
pcbeCriticalEventActive
NOTIFICATION-TYPE
SEVERE: PowerChute Business Edition has begun a safe shutdown of the host.
1.3.6.1.4.1.318.0.790
pcbeCriticalEventResolved
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute Business Edition critical event resolved. Safe shutdown will continue.
1.3.6.1.4.1.318.0.791
pcbeComsLost
NOTIFICATION-TYPE
SEVERE: PowerChute cannot communicate with UPS
1.3.6.1.4.1.318.0.792
pcbeComsLostResolved
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute can communicate with UPS again.
1.3.6.1.4.1.318.0.793
pcbeTest
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute has sent a test trap.
1.3.6.1.4.1.318.0.794
pcbeUpdateAvailable
NOTIFICATION-TYPE
INFORMATIONAL: PowerChute has detected that a newer version is available.
1.3.6.1.4.1.318.0.795
pmmCriticalCondition
NOTIFICATION-TYPE
SEVERE: A PMM critical condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message.
1.3.6.1.4.1.318.0.796
pmmCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A PMM critical condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message.
1.3.6.1.4.1.318.0.797
pmmWarningCondition
NOTIFICATION-TYPE
WARNING: A PMM warning condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message.
1.3.6.1.4.1.318.0.798
pmmWarningConditionCleared
NOTIFICATION-TYPE
WARNING: A PMM warning condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message.
1.3.6.1.4.1.318.0.799
pmmInformationalCondition
NOTIFICATION-TYPE
INFORMATIONAL: A PMM informational condition has been detected. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message.
1.3.6.1.4.1.318.0.800
pmmInformationalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A PMM informational condition has been cleared. The first variable is the serial number. The second variable is the device name. The third variable is the event ID. The fourth variable is the instance number. The fifth variable is the trap text message.
1.3.6.1.4.1.318.0.801
upsInputContactOutputRelayFault
NOTIFICATION-TYPE
SEVERE: A fault exists in the UPS input contact / output relay hardware.
1.3.6.1.4.1.318.0.802
upsInputContactOutputRelayFaultCleared
NOTIFICATION-TYPE
INFORMATIONAL: Fault no longer exists in the UPS input contact / output relay hardware.
1.3.6.1.4.1.318.0.803
upsAirFilterWarning
NOTIFICATION-TYPE
WARNING: Air filter requires service.
1.3.6.1.4.1.318.0.804
upsAirFilterWarningCleared
NOTIFICATION-TYPE
INFORMATIONAL: Air filter no longer requires service.
1.3.6.1.4.1.318.0.805
upsBatteryPackIncompatible
NOTIFICATION-TYPE
SEVERE: Incompatible battery pack.
1.3.6.1.4.1.318.0.806
upsBatteryPackIncompatibleCleared
NOTIFICATION-TYPE
INFORMATIONAL: Incompatible battery pack no longer present.
1.3.6.1.4.1.318.0.807
upsInputContactAbnormal
NOTIFICATION-TYPE
WARNING: UPS input contact is in the abnormal state.
1.3.6.1.4.1.318.0.808
upsInputContactAbnormalCleared
NOTIFICATION-TYPE
INFORMATIONAL: UPS input contact has returned to its normal state.
1.3.6.1.4.1.318.0.809
upsOutputRelayAbnormal
NOTIFICATION-TYPE
WARNING: A UPS output relay has switched to the abnormal state.
1.3.6.1.4.1.318.0.810
upsOutputRelayAbnormalCleared
NOTIFICATION-TYPE
INFORMATIONAL: A UPS output relay has returned to its normal state.
1.3.6.1.4.1.318.0.811
ePDUCriticalCondition
NOTIFICATION-TYPE
SEVERE: A EPDU critical condition has been detected.
1.3.6.1.4.1.318.0.812
ePDUCriticalConditionCleared
NOTIFICATION-TYPE
INFORMATIONAL: A EPDU critical condition has been cleared.
1.3.6.1.4.1.318.0.813
ePDUWarningCondition
NOTIFICATION-TYPE
SEVERE: A Easy PDU warning condition has been detected.
1.3.6.1.4.1.318.0.814
ePDUWarningConditionCleared
NOTIFICATION-TYPE
SEVERE: A Easy PDU warning condition has been cleared.
1.3.6.1.4.1.318.0.815