MIBs Depot

PoE-MIB

Registered at
1.3.6.1.4.1.171.12.24
Last updated
2010-12-24 00:00
Organization
D-Link Corp.
Namespace
dlink
Source file
PoE-MIB
Digest
sha256:ca21c0c8c41e6e4acbc0eb64d9cbc59a3b7fd35e067a4fe9cd07643850cfd805

Description

The Structure of PoE management for the proprietary enterprise.

Contact

http://support.dlink.com

Imports

FromSymbols
DLINK-ID-REC-MIBdlink-common-mgmt
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DLINK-ID-REC-MIB
PoE-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
swPoESystemCtrl
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.24.1
swPoESystemPowerLimit
OBJECT-TYPE
The power budget (in watts) of the PoE sytem.
1.3.6.1.4.1.171.12.24.1.1INTEGERread-writecurrent
swPoESystemPowerDisconnectMethod
OBJECT-TYPE
The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection, to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.
1.3.6.1.4.1.171.12.24.1.2INTEGER {denyNextPort(1), denyLowPriorityPort(2)}read-writecurrent
swPoESystemManagementMode
OBJECT-TYPE
This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be shut down. auto: The system will automatically determine the PD class of the device connected to the port in the first stage. Normally, the PD can be classified as class 1, 2, or 3. If the PD cannot be classified, it will be classified as class 0. For class 0, it will assume that the PD may consume the max power allowed. During the power feeding stage, if the power supplied to the port exceeds the upper limit of the detected PD class, this port will be shut down. For the upper limit for each class, it is 4W for class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.
1.3.6.1.4.1.171.12.24.1.3INTEGER {power-limit(1), auto(2)}read-writecurrent
swPoESystemLedMode
OBJECT-TYPE
Specifies if the system mode will be POE or NORMAL.
1.3.6.1.4.1.171.12.24.1.4INTEGER {normal(1), poe(2)}read-writecurrent
swPoESystemCtrlLegacyPD
OBJECT-TYPE
The legacy PD detection state. Enables or disables legacy PD detection on all PoE port.
1.3.6.1.4.1.171.12.24.1.6INTEGER {enabled(1), disabled(2)}read-writecurrent
swPoESystemStackingCtrlTable
OBJECT-TYPE
A table that is used to configure PoE system information based on Unit ID. The Unit ID is used for stacking.
1.3.6.1.4.1.171.12.24.1.11not-accessiblecurrent
swPoESystemStackingCtrlEntry
OBJECT-TYPE
A list of PoE system information based on Unit ID.
1.3.6.1.4.1.171.12.24.1.11.1not-accessiblecurrent
swPoESystemStackingCtrlUnitId
OBJECT-TYPE
This object indicates the device's Unit ID. A unit ID of zero denotes a stand-alone device.
1.3.6.1.4.1.171.12.24.1.11.1.1INTEGER (0..65535)read-onlycurrent
swPoESystemStackingCtrlPowerLimit
OBJECT-TYPE
The power budget (in watts) of the PoE sytem.
1.3.6.1.4.1.171.12.24.1.11.1.2INTEGERread-writecurrent
swPoESystemStackingCtrlPowerDisconnectMethod
OBJECT-TYPE
The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.
1.3.6.1.4.1.171.12.24.1.11.1.3INTEGER {denyNextPort(1), denyLowPriorityPort(2)}read-writecurrent
swPoESystemStackingCtrlManagementMode
OBJECT-TYPE
This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be shut down. auto: The system will automatically determine the PD class of the device connected to the port in the first stage. Normally, the PD can be classified as class 1, 2, or 3. If the PD can not be classified, it will be classified as class 0. For class 0, it will assume that the PD may consume the max power allowed. At the power feeding stage, if the power supplied to the port exceeds the upper limit of the detected PD class, this port will be shut down. For the upper limit for each class, it is 4W for class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.
1.3.6.1.4.1.171.12.24.1.11.1.4INTEGER {power-limit(1), auto(2)}read-writecurrent
swPoESystemStackingCtrlLedMode
OBJECT-TYPE
Specifies the system mode to be POE or NORMAL.
1.3.6.1.4.1.171.12.24.1.11.1.5INTEGER {normal(1), poe(2)}read-writecurrent
swPoESystemStackingCtrlLegacyPD
OBJECT-TYPE
The legacy PD detection state. Enables or disables legacy PD detection on PoE unit.
1.3.6.1.4.1.171.12.24.1.11.1.6INTEGER {enabled(1), disabled(2)}read-writecurrent
swPoESystemInfo
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.24.2
swPoESystemInfoTable
OBJECT-TYPE
A table that contains PoE system information based on Unit ID. The Unit ID is used for stacking.
1.3.6.1.4.1.171.12.24.2.1not-accessiblecurrent
swPoESystemInfoEntry
OBJECT-TYPE
A list of PoE system information based on Unit ID.
1.3.6.1.4.1.171.12.24.2.1.1not-accessiblecurrent
swPoESystemInfoUnitId
OBJECT-TYPE
This object indicates the device's Unit ID. A unit ID of zero denotes a stand-alone device.
1.3.6.1.4.1.171.12.24.2.1.1.1INTEGER (0..65535)read-onlycurrent
swPoESystemInfoPowerConsumption
OBJECT-TYPE
The actual momentary power consumption (in watts) in the PoE system.
1.3.6.1.4.1.171.12.24.2.1.1.2INTEGERread-onlycurrent
swPoESystemInfoPowerRemained
OBJECT-TYPE
The actual momentary remaining power (in watts) in the PoE system.
1.3.6.1.4.1.171.12.24.2.1.1.3INTEGERread-onlycurrent
swPoESystemInfoPowerLimit
OBJECT-TYPE
The power budget (in watts) of the PoE sytem.
1.3.6.1.4.1.171.12.24.2.1.1.4INTEGERread-onlycurrent
swPoESystemInfoPowerDisconnectMethod
OBJECT-TYPE
The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.
1.3.6.1.4.1.171.12.24.2.1.1.5INTEGER {denyNextPort(1), denyLowPriorityPort(2)}read-onlycurrent
swPoESystemInfoManagementMode
OBJECT-TYPE
This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be shut down. auto: The system will automatically determine the PD class of the device connected to the port in the first stage. Normally, the PD can be classified as class 1, 2, or 3. If the PD can not be classified, it will be classified as class 0. For class 0, it will assume that the PD may consume the max power allowed. At the power feeding stage, if the power supplied to the port exceeds the upper limit of the detected PD class, this port will be shut down. For the upper limit for each class, it is 4W for class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.
1.3.6.1.4.1.171.12.24.2.1.1.6INTEGER {power-limit(1), auto(2)}read-onlycurrent
swPoESystemInfoLegacyPD
OBJECT-TYPE
The current status of legacy PD detection.
1.3.6.1.4.1.171.12.24.2.1.1.7INTEGER {enabled(1), disabled(2)}read-onlycurrent
swPoEPortCtrl
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.24.3
swPoEPortCtrlTable
OBJECT-TYPE
A table that contains PoE configuration about every port in this stack. If a device has N ports, then the 1 -- N ports describe the port number of BoxId 1 device; N+1 -- 2N describe the port number of BoxId 2 device; 2N+1 -- 3N describe the port number of BoxId 2 device; ......
1.3.6.1.4.1.171.12.24.3.1not-accessiblecurrent
swPoEPortCtrlEntry
OBJECT-TYPE
A list of PoE configurations for each port of the device in this stack.
1.3.6.1.4.1.171.12.24.3.1.1not-accessiblecurrent
swPoEPortCtrlPortIndex
OBJECT-TYPE
This object indicates the devices' port number in this stack. If a device has N ports, then the 1 -- N ports describe the port number of BoxId 1 device; N+1 -- 2N describe the port number of BoxId 2 device; 2N+1 -- 3N describe the port number of BoxId 2 device; ......
1.3.6.1.4.1.171.12.24.3.1.1.1INTEGER (0..65535)read-onlycurrent
swPoEPortCtrlState
OBJECT-TYPE
The PoE port state. Enables or disables the PoE function on the specific port. The default setting is enable.
1.3.6.1.4.1.171.12.24.3.1.1.2INTEGER {other(1), enable(2), disable(3)}read-writecurrent
swPoEPortCtrlPriority
OBJECT-TYPE
The PoE port priority. Port priority affects power-up order (after a rest, the ports are powered up according to their priority) and shutdown order (when exceeding the power budget, the ports are shut down according to their priority if power_disconnect_method is set to deny_low_priority_port) Default setting is low.
1.3.6.1.4.1.171.12.24.3.1.1.3INTEGER {critical(1), high(2), low(3)}read-writecurrent
swPoEPortCtrlPowerLimit
OBJECT-TYPE
There are 4 pre-defined values for users' convenience to set the upper power limit for class 0, class 1, class 2, and class 3. class_0: 15400mW (The maximum power provided by PSE (switch) is 12.95 W + power loss on cable) class_1: 4000mW (The maximum power provided by PSE is 3.84 W + power loss on cable) class_2: 7000mW (The maximum power provided by PSE is 6.49 W + power loss on cable) class_3: 15400mW (The maximum power provided by PSE is 12.95 W + power loss on cable) user-defined: User can select this setting and configure the range in swPoEPortCtrlUserDefined.
1.3.6.1.4.1.171.12.24.3.1.1.4INTEGER {class0(1), class1(2), class2(3), class3(4), user-defined(5)}read-writecurrent
swPoEPortCtrlUserDefined
OBJECT-TYPE
User defined per-port power limit (in milliwatts). If a port exceeds 10% of its power limit, the PoE system will shut down that port. The default setting is 15400 mW. Note: This object is valid only while the swPoEPortCtrlPowerLimit object is configured as user-defined.
1.3.6.1.4.1.171.12.24.3.1.1.5INTEGER (1000..35000)read-writecurrent
swPoEPortCtrlTimeRangeName
OBJECT-TYPE
Specifies the time_range that applies to the port of the POE.If time range is configured, power can only be supplied during the period specified by the time range.
1.3.6.1.4.1.171.12.24.3.1.1.6SnmpAdminString (SIZE(0..32))read-writecurrent
swPoEPortInfo
OBJECT-IDENTITY
1.3.6.1.4.1.171.12.24.4
swPoEPortInfoTable
OBJECT-TYPE
A table that contains PoE information about every port in this stack. If a device has N ports, then the 1 -- N ports describe the port number of BoxID 1 device; N+1 -- 2N describe the port number of BoxID 2 device; 2N+1 -- 3N describe the port number of BoxID 2 device; ......
1.3.6.1.4.1.171.12.24.4.1not-accessiblecurrent
swPoEPortInfoEntry
OBJECT-TYPE
A list of PoE information for each port of the device in this stack.
1.3.6.1.4.1.171.12.24.4.1.1not-accessiblecurrent
swPoEPortInfoPortIndex
OBJECT-TYPE
This object indicates the devices' port number in this stack. If a device has N ports, then the 1 -- N ports describe the port number of BoxId 1 device; N+1 -- 2N describe the port number of BoxID 2 device; 2N+1 -- 3N describe the port number of BoxID 2 device; ......
1.3.6.1.4.1.171.12.24.4.1.1.1INTEGER (0..65535)read-onlycurrent
swPoEPortInfoClass
OBJECT-TYPE
The power class of the PD according to 802.3af definitions: class 0: PD power consumption is within 0.44-12.95 watts, class 1: PD power consumption is within 0.44-3.84 watts, class 2: PD power consumption is within 3.84-6.49 watts, class 3: PD power consumption is within 6.49-12.95 watts, class 4: is reserved for future use.
1.3.6.1.4.1.171.12.24.4.1.1.2INTEGER (0..4)read-onlycurrent
swPoEPortInfoPower
OBJECT-TYPE
The port power consumption (in milliwatts).
1.3.6.1.4.1.171.12.24.4.1.1.3INTEGERread-onlycurrent
swPoEPortInfoVoltage
OBJECT-TYPE
The port input line voltage (in decivolts).
1.3.6.1.4.1.171.12.24.4.1.1.4INTEGERread-onlycurrent
swPoEPortInfoCurrent
OBJECT-TYPE
The port current (calculated in milliamps).
1.3.6.1.4.1.171.12.24.4.1.1.5INTEGERread-onlycurrent
swPoEPortInfoStatus
OBJECT-TYPE
The string describes the PoE port current status.
1.3.6.1.4.1.171.12.24.4.1.1.6DisplayString (SIZE(0..76))read-onlycurrent
swpoEPortInfoLedStatus
OBJECT-TYPE
The LED display for PoE port status. on (1): power is provided to the port on which a 802.3af-compliant or legacy PD is connected, off(2): no power is provided to the port where there aren't any errors, error(3): some error happens on the port, like overload, underload, short,...or power budget exceeded conditions.
1.3.6.1.4.1.171.12.24.4.1.1.7INTEGER {on(1), off(2), error(3)}read-onlycurrent